Rajarathinam T, Thirumalai D, Jayaraman S, Yang S, Ishigami A, Yoon JH, Paik HJ, Lee J, Chang SC. Glutamate oxidase sheets-Prussian blue grafted amperometric biosensor for the real time monitoring of glutamate release from primary cortical neurons. Int J Biol Macromol 2024; 254:127903. [PMID: 37939751 DOI: 10.1016/j.ijbiomac.2023.127903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 10/25/2023] [Accepted: 11/03/2023] [Indexed: 11/10/2023]
Abstract
Glutamate (GLU) is a primary excitatory neurotransmitter, and its dysregulation is associated with several neurodegenerative disorders. A major challenge in GLU estimation is the existence of other biomolecules in the brain that could directly get oxidized at the electrode. Hence, highly selective electroenzymatic biosensors that enable rapid estimation of GLU are needed. Initially, a copolymer, poly(2-dimethylaminoethyl methacrylate- styrene) was synthesized through reversible addition-fragmentation chain transfer polymerization to noncovalently functionalize reduced graphene oxide (rGO), named DS-rGO. Glutamate oxidase macromolecule immobilized DS-rGO formed enzyme nanosheets, which was drop-coated over Prussian blue electrodeposited disposable electrodes to fabricate the GLU biosensor. The interconnectivity between the enzyme nanosheets and the Prussian blue endows the biosensor with enhanced conductivity and electrochemical activity. The biosensor exhibited a linearity: 3.25-250 μM; sensitivity: 3.96 μA mM-1 cm-2, and a limit of detection: 0.96 μM for GLU in the Neurobasal Medium. The biosensor was applied to an in vitro primary rat cortical model to discriminate GLU levels in Neurobasal Medium, before and after KCl mediated depolarization, which provides new insights for elucidating neuronal functioning in the brain.
Collapse
Affiliation(s)
- Thenmozhi Rajarathinam
- Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 46241, Republic of Korea
| | - Dinakaran Thirumalai
- BIT Convergence-based Innovative Drug Development Targeting Metainflammation, Pusan National University, Busan 46241, Republic of Korea
| | - Sivaguru Jayaraman
- Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 46241, Republic of Korea
| | - Seonguk Yang
- Department of Pharmacy, College of Pharmacy, Pusan National University, Busan 46241, Republic of Korea
| | - Akihito Ishigami
- Molecular Regulation of Aging, Tokyo Metropolitan Institute of Gerontology, Tokyo 173-0015, Japan
| | - Jang-Hee Yoon
- Busan Center, Korea Basic Science Institute, Busan 46241, Republic of Korea
| | - Hyun-Jong Paik
- Department of Polymer Science and Engineering, Pusan National University, Busan 46241, Republic of Korea
| | - Jaewon Lee
- Department of Pharmacy, College of Pharmacy, Pusan National University, Busan 46241, Republic of Korea.
| | - Seung-Cheol Chang
- Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 46241, Republic of Korea.
| |
Collapse
|
2
|
Dias C, Fernandes E, Barbosa RM, Ledo A. A Platinized Carbon Fiber Microelectrode-Based Oxidase Biosensor for Amperometric Monitoring of Lactate in Brain Slices. SENSORS (BASEL, SWITZERLAND) 2022; 22:7011. [PMID: 36146360 PMCID: PMC9501957 DOI: 10.3390/s22187011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2022] [Revised: 09/12/2022] [Accepted: 09/14/2022] [Indexed: 06/16/2023]
Abstract
BACKGROUND Direct and real-time monitoring of lactate in the extracellular space can help elucidate the metabolic and modulatory role of lactate in the brain. Compared to in vivo studies, brain slices allow the investigation of the neural contribution separately from the effects of cerebrovascular response and permit easy control of recording conditions. METHODS We have used a platinized carbon fiber microelectrode platform to design an oxidase-based microbiosensor for monitoring lactate in brain slices with high spatial and temporal resolution operating at 32 °C. Lactate oxidase (Aerococcus viridans) was immobilized by crosslinking with glutaraldehyde and a layer of polyurethane was added to extend the linear range. Selectivity was improved by electropolymerization of m-phenylenediamine and concurrent use of a null sensor. RESULTS The lactate microbiosensor exhibited high sensitivity, selectivity, and optimal analytical performance at a pH and temperature compatible with recording in hippocampal slices. Evaluation of operational stability under conditions of repeated use supports the suitability of this design for up to three repeated assays. CONCLUSIONS The microbiosensor displayed good analytical performance to monitor rapid changes in lactate concentration in the hippocampal tissue in response to potassium-evoked depolarization.
Collapse
Affiliation(s)
- Cândida Dias
- Center for Neuroscience and Cell Biology, University of Coimbra, 3004-504 Coimbra, Portugal
- Faculty of Pharmacy, University of Coimbra, 3000-548 Coimbra, Portugal
| | - Eliana Fernandes
- Center for Neuroscience and Cell Biology, University of Coimbra, 3004-504 Coimbra, Portugal
- Faculty of Pharmacy, University of Coimbra, 3000-548 Coimbra, Portugal
| | - Rui M. Barbosa
- Center for Neuroscience and Cell Biology, University of Coimbra, 3004-504 Coimbra, Portugal
- Faculty of Pharmacy, University of Coimbra, 3000-548 Coimbra, Portugal
| | - Ana Ledo
- Center for Neuroscience and Cell Biology, University of Coimbra, 3004-504 Coimbra, Portugal
- Faculty of Pharmacy, University of Coimbra, 3000-548 Coimbra, Portugal
| |
Collapse
|
3
|
Fernandes E, Ledo A, Barbosa RM. Design and Evaluation of a Lactate Microbiosensor: Toward Multianalyte Monitoring of Neurometabolic Markers In Vivo in the Brain. MOLECULES (BASEL, SWITZERLAND) 2022; 27:molecules27020514. [PMID: 35056837 PMCID: PMC8780383 DOI: 10.3390/molecules27020514] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 01/10/2022] [Accepted: 01/11/2022] [Indexed: 12/22/2022]
Abstract
Direct in vivo measurements of neurometabolic markers in the brain with high spatio-temporal resolution, sensitivity, and selectivity is highly important to understand neurometabolism. Electrochemical biosensors based on microelectrodes are very attractive analytical tools for continuous monitoring of neurometabolic markers, such as lactate and glucose in the brain extracellular space at resting and following neuronal activation. Here, we assess the merits of a platinized carbon fiber microelectrode (CFM/Pt) as a sensing platform for developing enzyme oxidase-based microbiosensors to measure extracellular lactate in the brain. Lactate oxidase was immobilized on the CFM/Pt surface by crosslinking with glutaraldehyde. The CFM/Pt-based lactate microbiosensor exhibited high sensitivity and selectivity, good operational stability, and low dependence on oxygen, temperature, and pH. An array consisting of a glucose and lactate microbiosensors, including a null sensor, was used for concurrent measurement of both neurometabolic substrates in vivo in the anesthetized rat brain. Rapid changes of lactate and glucose were observed in the cortex and hippocampus in response to local glucose and lactate application and upon insulin-induced fluctuations of systemic glucose. Overall, these results indicate that microbiosensors are a valuable tool to investigate neurometabolism and to better understand the role of major neurometabolic markers, such as lactate and glucose.
Collapse
Affiliation(s)
- Eliana Fernandes
- Faculty of Pharmacy, University of Coimbra, 3000-548 Coimbra, Portugal; (E.F.); (A.L.)
- Center for Neuroscience and Cell Biology, University of Coimbra, 3004-504 Coimbra, Portugal
| | - Ana Ledo
- Faculty of Pharmacy, University of Coimbra, 3000-548 Coimbra, Portugal; (E.F.); (A.L.)
- Center for Neuroscience and Cell Biology, University of Coimbra, 3004-504 Coimbra, Portugal
| | - Rui M. Barbosa
- Faculty of Pharmacy, University of Coimbra, 3000-548 Coimbra, Portugal; (E.F.); (A.L.)
- Center for Neuroscience and Cell Biology, University of Coimbra, 3004-504 Coimbra, Portugal
- Correspondence:
| |
Collapse
|
4
|
Regiart M, Ledo A, Fernandes E, Messina GA, Brett CMA, Bertotti M, Barbosa RM. Highly sensitive and selective nanostructured microbiosensors for glucose and lactate simultaneous measurements in blood serum and in vivo in brain tissue. Biosens Bioelectron 2021; 199:113874. [PMID: 34920228 DOI: 10.1016/j.bios.2021.113874] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2021] [Revised: 12/06/2021] [Accepted: 12/07/2021] [Indexed: 02/06/2023]
Abstract
Highly sensitive and selective nanostructured lactate and glucose microbiosensors for their in vivo simultaneous determination in rat brain were developed based on carbon fiber microelectrodes (CFM) modified with nanoporous gold (NPG) using the Dynamic Hydrogen Bubble Template (DHBT) method. Electrodeposition of platinum nanoparticles (PtNP) onto the NPG film enhances the sensitivity and the electrocatalytic properties towards H2O2 detection. The nanostructured microelectrode platform was modified by glucose oxidase (GOx) and lactate oxidase (LOx) enzyme immobilization. High selective measurements were achieved by covering with a perm-selective layer of electropolymerized m-phenylenediamine, deposition of a Nafion® film and by using a null sensor. The morphological characteristics and electroanalytical performance of the microbiosensors were assessed, by scanning electron microscopy and electrochemical techniques, respectively. The PtNP/NPG/CFM shows a high sensitivity to H2O2 (5.96 A M-1 cm-2) at 0.36 V vs. Ag/AgCl, with a linear range from 0.2 to 200 μM, and an LOD of 10 nM. The microbiosensors were applied to the simultaneous determination of lactate and glucose in blood serum samples. Moreover, the basal extracellular concentrations of lactate and glucose were measured in vivo in four different rat brain structures. These results support the potential of the microbiosensor to be used as a valuable tool to investigate brain neurochemicals in vivo.
Collapse
Affiliation(s)
- Matias Regiart
- University of Coimbra, Faculty of Pharmacy, Azinhaga de Santa Comba, 3000-548, Coimbra, Portugal; Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes 748, 05508-000, São Paulo, SP, Brazil
| | - Ana Ledo
- University of Coimbra, Faculty of Pharmacy, Azinhaga de Santa Comba, 3000-548, Coimbra, Portugal; Center for Neuroscience and Cell Biology, University of Coimbra, Rua Larga, 3004-504, Coimbra, Portugal
| | - Eliana Fernandes
- University of Coimbra, Faculty of Pharmacy, Azinhaga de Santa Comba, 3000-548, Coimbra, Portugal
| | - German A Messina
- INQUISAL. Departamento de Química, Universidad Nacional de San Luis. CONICET, Chacabuco 917, D5700BWS, San Luis, Argentina
| | - Christopher M A Brett
- University of Coimbra, Department of Chemistry, CEMMPRE, Faculty of Sciences and Technology, 3004-535 Coimbra, Portugal
| | - Mauro Bertotti
- Department of Fundamental Chemistry, Institute of Chemistry, University of São Paulo, Av. Prof. Lineu Prestes 748, 05508-000, São Paulo, SP, Brazil
| | - Rui M Barbosa
- University of Coimbra, Faculty of Pharmacy, Azinhaga de Santa Comba, 3000-548, Coimbra, Portugal; Center for Neuroscience and Cell Biology, University of Coimbra, Rua Larga, 3004-504, Coimbra, Portugal.
| |
Collapse
|
5
|
Kim SJ, Shin W. Glucose Diffusion Limiting Membrane Based on Polyethyleneimine (PEI) Hydrogel for the Stabilization of Glucose Sensor. J ELECTROCHEM SCI TE 2021. [DOI: 10.33961/jecst.2020.01487] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
6
|
Development of three-enzyme lactose amperometric biosensor modified by nanosized poly (meta-phenylenediamine) film. APPLIED NANOSCIENCE 2021. [DOI: 10.1007/s13204-021-01859-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
|
7
|
Ahmadi Y, Kim KH. Functionalization and customization of polyurethanes for biosensing applications: A state-of-the-art review. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115881] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
8
|
Mentana A, Nardiello D, Palermo C, Centonze D. Accurate glutamate monitoring in foodstuffs by a sensitive and interference-free glutamate oxidase based disposable amperometric biosensor. Anal Chim Acta 2020; 1115:16-22. [PMID: 32370865 DOI: 10.1016/j.aca.2020.04.020] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2020] [Revised: 04/07/2020] [Accepted: 04/08/2020] [Indexed: 02/05/2023]
Abstract
L-Glutamate (L-Glu) is a well-known flavour enhancer that is present in several foodstuffs. Although L-Glu is generally recognized as safe, the use in foodstuffs remains controversial and then its fast and accurate monitoring represents an important issue. In this work a sensitive and interference-free disposable amperometric biosensor for glutamate monitoring in foodstuffs was developed. The biosensor was prepared by immobilizing glutamate oxidase through co-crosslinking with bovine serum albumin and glutaraldehyde onto a screen printed disposable platinum electrode modified with a permselective overoxidized polypyrrole film. The enzyme immobilization was optimized by using different experimental procedures. The optimized glutamate biosensor was integrated in a flow injection system and characterized in terms of linearity (0.005-1.0 mM, r2 = 0.992), limits of detection (1.8 μM) and quantitation (5.4 μM), repeatability (RSD < 3%) and stability of response under operational conditions (up to 50 h, over 400 analysis). The biosensor showed also excellent anti-interference characteristics towards the main electroactive interferents present in food matrices, and this allowed the application to the accurate monitoring of glutamate in different foodstuffs.
Collapse
Affiliation(s)
- Annalisa Mentana
- Dipartimento di Scienze Agrarie, degli Alimenti e dell'Ambiente, Università degli Studi di Foggia, via Napoli, 25 - 71122, Foggia, Italy
| | - Donatella Nardiello
- Dipartimento di Scienze Agrarie, degli Alimenti e dell'Ambiente, Università degli Studi di Foggia, via Napoli, 25 - 71122, Foggia, Italy
| | - Carmen Palermo
- Dipartimento di Scienze Agrarie, degli Alimenti e dell'Ambiente, Università degli Studi di Foggia, via Napoli, 25 - 71122, Foggia, Italy
| | - Diego Centonze
- Dipartimento di Scienze Agrarie, degli Alimenti e dell'Ambiente, Università degli Studi di Foggia, via Napoli, 25 - 71122, Foggia, Italy.
| |
Collapse
|
9
|
Hajikarimi A, Sadeghi M. Free radical synthesis of cross-linking gelatin base poly NVP/acrylic acid hydrogel and nanoclay hydrogel as cephalexin drug deliver. JOURNAL OF POLYMER RESEARCH 2020. [DOI: 10.1007/s10965-020-2020-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
10
|
Nolan JK, Nguyen TNH, Le KVH, DeLong LE, Lee H. Simple Fabrication of Flexible Biosensor Arrays Using Direct Writing for Multianalyte Measurement from Human Astrocytes. SLAS Technol 2020; 25:33-46. [PMID: 31766939 PMCID: PMC7263197 DOI: 10.1177/2472630319888442] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Simultaneous measurements of glucose, lactate, and neurotransmitters (e.g., glutamate) in cell culture over hours and days can provide a more dynamic and longitudinal perspective on ways neural cells respond to various drugs and environmental cues. Compared with conventional microfabrication techniques, direct writing of conductive ink is cheaper, faster, and customizable, which allows rapid iteration for different applications. Using a simple direct writing technique, we printed biosensor arrays onto cell culture dishes, flexible laminate, and glass to enable multianalyte monitoring. The ink was a composite of PEDOT:PSS conductive polymer, silicone, activated carbon, and Pt microparticles. We applied 0.5% Nafion to the biosensors for selectivity and functionalized them with oxidase enzymes. We characterized biosensors in phosphate-buffered saline and in cell culture medium supplemented with fetal bovine serum. The biosensor arrays measured glucose, lactate, and glutamate simultaneously and continued to function after incubation in cell culture at 37 °C for up to 2 days. We cultured primary human astrocytes on top of the biosensor arrays and placed arrays into astrocyte cultures. The biosensors simultaneously measured glucose, glutamate, and lactate from astrocyte cultures. Direct writing can be integrated with microfluidic organ-on-a-chip platforms or as part of a smart culture dish system. Because we print extrudable and flexible components, sensing elements can be printed on any 3D or flexible substrate.
Collapse
Affiliation(s)
- James K. Nolan
- Weldon School of Biomedical Engineering, Center for Implantable Devices, Birck Nanotechnology Center, Purdue University, West Lafayette, IN, USA
| | - Tran N. H. Nguyen
- Weldon School of Biomedical Engineering, Center for Implantable Devices, Birck Nanotechnology Center, Purdue University, West Lafayette, IN, USA
| | - Khanh Vy H. Le
- Weldon School of Biomedical Engineering, Center for Implantable Devices, Birck Nanotechnology Center, Purdue University, West Lafayette, IN, USA
| | - Luke E. DeLong
- Weldon School of Biomedical Engineering, Center for Implantable Devices, Birck Nanotechnology Center, Purdue University, West Lafayette, IN, USA
| | - Hyowon Lee
- Weldon School of Biomedical Engineering, Center for Implantable Devices, Birck Nanotechnology Center, Purdue University, West Lafayette, IN, USA
| |
Collapse
|
11
|
Lourenço CF, Caetano M, Ledo A, Barbosa RM. Platinized carbon fiber-based glucose microbiosensor designed for metabolic studies in brain slices. Bioelectrochemistry 2019; 130:107325. [DOI: 10.1016/j.bioelechem.2019.06.010] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 06/25/2019] [Accepted: 06/25/2019] [Indexed: 12/12/2022]
|
12
|
Wang B, Wen X, Chiou P, Maidment NT. Pt Nanoparticle‐modified Carbon Fiber Microelectrode for Selective Electrochemical Sensing of Hydrogen Peroxide. ELECTROANAL 2019. [DOI: 10.1002/elan.201900362] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Bo Wang
- Shirley and Stephan Hatos Center for Neuropharmacology, Department of Psychiatry and Biobehavioral Sciences, Semel Institute for Neuroscience and Human BehaviorUniversity of California, Los Angeles Los Angeles, CA USA
| | - Ximiao Wen
- Department of Mechanical EngineeringUniversity of California, Los Angeles Los Angeles, CA USA
| | - Pei‐Yu Chiou
- Department of Mechanical EngineeringUniversity of California, Los Angeles Los Angeles, CA USA
| | - Nigel T. Maidment
- Shirley and Stephan Hatos Center for Neuropharmacology, Department of Psychiatry and Biobehavioral Sciences, Semel Institute for Neuroscience and Human BehaviorUniversity of California, Los Angeles Los Angeles, CA USA
| |
Collapse
|
13
|
Dudina A, Frey U, Hierlemann A. Carbon-Nanotube-Based Monolithic CMOS Platform for Electrochemical Detection of Neurotransmitter Glutamate. SENSORS (BASEL, SWITZERLAND) 2019; 19:E3080. [PMID: 31336874 PMCID: PMC6660312 DOI: 10.3390/s19143080] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 05/04/2019] [Revised: 07/02/2019] [Accepted: 07/03/2019] [Indexed: 02/02/2023]
Abstract
We present a monolithic biosensor platform, based on carbon-nanotube field-effect transistors (CNTFETs), for the detection of the neurotransmitter glutamate. We used an array of 9'216 CNTFET devices with 96 integrated readout and amplification channels that was realized in complementary metal-oxide semiconductor technology (CMOS). The detection principle is based on amperometry, where electrochemically active hydrogen peroxide, a product of the enzymatic reaction of the target analyte and an enzyme that was covalently bonded to the CNTFET, modulated the conductance of the CNTFET-based sensors. We assessed the performance of the CNTs as enzymatic sensors by evaluating the minimal resolvable concentration change of glutamate in aqueous solutions. The minimal resolvable concentration change amounted to 10 µM of glutamate, which was one of the best values reported for CMOS-based systems so far.
Collapse
Affiliation(s)
- Alexandra Dudina
- Bio Engineering Laboratory, Department of Biosystems Science and Engineering, ETH Zurich, Mattenstrasse 26, CH-4058 Basel, Switzerland.
| | - Urs Frey
- Bio Engineering Laboratory, Department of Biosystems Science and Engineering, ETH Zurich, Mattenstrasse 26, CH-4058 Basel, Switzerland
- MaxWell Biosystems AG, CH-4058 Basel, Switzerland
| | - Andreas Hierlemann
- Bio Engineering Laboratory, Department of Biosystems Science and Engineering, ETH Zurich, Mattenstrasse 26, CH-4058 Basel, Switzerland
| |
Collapse
|
14
|
Karakaya S, Dilgin Y. Minimization of Interferences in Flow Injection Amperometric Glucose Biosensor Based on Oxidation of Enzymatically‐produced H
2
O
2. ELECTROANAL 2019. [DOI: 10.1002/elan.201800887] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Serkan Karakaya
- Çanakkale Onsekiz Mart UniversityScience and Arts Faculty, Department of Chemistry 17100 Çanakkale Turkey
| | - Yusuf Dilgin
- Çanakkale Onsekiz Mart UniversityScience and Arts Faculty, Department of Chemistry 17100 Çanakkale Turkey
| |
Collapse
|
15
|
Low-Temperature Storage Improves the Over-Time Stability of Implantable Glucose and Lactate Biosensors. SENSORS 2019; 19:s19020422. [PMID: 30669626 PMCID: PMC6359396 DOI: 10.3390/s19020422] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/21/2018] [Revised: 01/09/2019] [Accepted: 01/18/2019] [Indexed: 12/31/2022]
Abstract
Molecular biomarkers are very important in biology, biotechnology and even in medicine, but it is quite hard to convert biology-related signals into measurable data. For this purpose, amperometric biosensors have proven to be particularly suitable because of their specificity and sensitivity. The operation and shelf stability of the biosensor are quite important features, and storage procedures therefore play an important role in preserving the performance of the biosensors. In the present study two different designs for both glucose and lactate biosensor, differing only in regards to the containment net, represented by polyurethane or glutharaldehyde, were studied under different storage conditions (+4, −20 and −80 °C) and monitored over a period of 120 days, in order to evaluate the variations of kinetic parameters, as VMAX and KM, and LRS as the analytical parameter. Surprisingly, the storage at −80 °C yielded the best results because of an unexpected and, most of all, long-lasting increase of VMAX and LRS, denoting an interesting improvement in enzyme performances and stability over time. The present study aimed to also evaluate the impact of a short-period storage in dry ice on biosensor performances, in order to simulate a hypothetical preparation-conservation-shipment condition.
Collapse
|
16
|
An enzyme-based electrochemical biosensor probe with sensitivity to detect astrocytic versus glioma uptake of glutamate in real time in vitro. Biosens Bioelectron 2018; 126:751-757. [PMID: 30553105 DOI: 10.1016/j.bios.2018.11.023] [Citation(s) in RCA: 25] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/19/2018] [Revised: 11/03/2018] [Accepted: 11/15/2018] [Indexed: 12/31/2022]
Abstract
Glutamate, a major excitatory neurotransmitter in the central nervous system, is essential for regulation of thought, movement, memory, and other higher functions controlled by the brain. Dysregulation of glutamate signaling is associated with severe neuropathological conditions, such as epilepsy, and glioma, a form of brain cancer. Glutamate signals are currently detected by several types of neurochemical probes ranging from microdialysis-based to enzyme-based carbon fiber microsensors. However, an important technology gap exists in the ability to measure glutamate dynamics continuously, and in real time, and from multiple locations in the brain, which limits our ability to further understand the involved spatiotemporal mechanisms of underlying neuropathologies. To overcome this limitation, we developed an enzymatic glutamate microbiosensor, in the form of a ceramic-substrate enabled platinum microelectrode array, that continuously, in real time, measures changes in glutamate concentration from multiple recording sites. In addition, the developed microbiosensor is almost four-fold more sensitive to glutamate than enzymatic sensors previously reported in the literature. Further analysis of glutamate dynamics recorded by our microbiosensor in cultured astrocytes (control condition) and glioma cells (pathological condition) clearly distinguished normal versus impaired glutamate uptake, respectively. These results confirm that the developed glutamate microbiosensor array can become a useful tool in monitoring and understanding glutamate signaling and its regulation in normal and pathological conditions. Furthermore, the developed microbiosensor can be used to measure the effects of potential therapeutic drugs to treat a range of neurological diseases.
Collapse
|
17
|
Hughes G, Pemberton RM, Nicholas P, Hart JP. Fabrication of Miniaturised Screen-printed Glucose Biosensors, Using a Water-based Ink, and the Evaluation of their Electrochemical Behaviour. ELECTROANAL 2018. [DOI: 10.1002/elan.201800104] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- G. Hughes
- Centre for Research in Biosciences, Faculty of Health and Applied Sciences; University of the West of England, Bristol; Coldharbour Lane Bristol BS16 1QY
| | - R. M. Pemberton
- Centre for Research in Biosciences, Faculty of Health and Applied Sciences; University of the West of England, Bristol; Coldharbour Lane Bristol BS16 1QY
| | - P. Nicholas
- The Gwent Group, Gwent Electronic Materials; Gwent Group Ltd.; Monmouth House, Mamhilad Park Pontypool NP4 OHZ UK
| | - J. P. Hart
- Centre for Research in Biosciences, Faculty of Health and Applied Sciences; University of the West of England, Bristol; Coldharbour Lane Bristol BS16 1QY
| |
Collapse
|
18
|
Chatard C, Meiller A, Marinesco S. Microelectrode Biosensors forin vivoAnalysis of Brain Interstitial Fluid. ELECTROANAL 2018. [DOI: 10.1002/elan.201700836] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Charles Chatard
- INSERM U1028, CNRS UMR5292; Lyon Neuroscience Research Center, Team TIGER
- Université Claude Bernard Lyon 1; Lyon France
| | - Anne Meiller
- AniRA-Neurochem Technological Platform; Lyon France
- Université Claude Bernard Lyon 1; Lyon France
| | - Stéphane Marinesco
- INSERM U1028, CNRS UMR5292; Lyon Neuroscience Research Center, Team TIGER
- AniRA-Neurochem Technological Platform; Lyon France
- Université Claude Bernard Lyon 1; Lyon France
- Lyon Neuroscience Research Center, Team TIGER; Faculty of Medicine; 8 Avenue Rockefeller 69373 Lyon Cedex 08 France
| |
Collapse
|
19
|
Hoa LNQ, Chen HR, Tseng TTC. An Arrayed Micro-glutamate Sensor Probe Integrated with On-probe Ag/AgCl Reference and Counter Electrodes. ELECTROANAL 2018. [DOI: 10.1002/elan.201700762] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Le Ngoc Quynh Hoa
- Department of Chemical Engineering; National Taiwan University of Science and Technology; Taipei 10607 Taiwan
| | - Hong-Ru Chen
- Department of Chemical Engineering; National Taiwan University of Science and Technology; Taipei 10607 Taiwan
| | - Tina T.-C. Tseng
- Department of Chemical Engineering; National Taiwan University of Science and Technology; Taipei 10607 Taiwan
| |
Collapse
|
20
|
Counting the number of enzymes immobilized onto a nanoparticle-coated electrode. Anal Bioanal Chem 2017; 410:1775-1783. [PMID: 29279991 PMCID: PMC5807476 DOI: 10.1007/s00216-017-0829-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2017] [Revised: 11/30/2017] [Accepted: 12/13/2017] [Indexed: 11/24/2022]
Abstract
To immobilize enzymes at the surface of a nanoparticle-based electrochemical sensor is a common method to construct biosensors for non-electroactive analytes. Studying the interactions between the enzymes and nanoparticle support is of great importance in optimizing the conditions for biosensor design. This can be achieved by using a combination of analytical methods to carefully characterize the enzyme nanoparticle coating at the sensor surface while studying the optimal conditions for enzyme immobilization. From this analytical approach, it was found that controlling the enzyme coverage to a monolayer was a key factor to significantly improve the temporal resolution of biosensors. However, these characterization methods involve both tedious methodologies and working with toxic cyanide solutions. Here we introduce a new analytical method that allows direct quantification of the number of immobilized enzymes (glucose oxidase) at the surface of a gold nanoparticle coated glassy carbon electrode. This was achieved by exploiting an electrochemical stripping method for the direct quantification of the density and size of gold nanoparticles coating the electrode surface and combining this information with quantification of fluorophore-labeled enzymes bound to the sensor surface after stripping off their nanoparticle support. This method is both significantly much faster compared to previously reported methods and with the advantage that this method presented is non-toxic. A new analytical method for direct quantification of the number of enzymes immobilized at the surface of gold nanoparticles covering a glassy carbon electrode using anodic stripping and fluorimetry ![]()
Collapse
|
21
|
Soldatkina OV, Kucherenko IS, Pyeshkova VM, Alekseev SA, Soldatkin OO, Dzyadevych SV. Improvement of amperometric transducer selectivity using nanosized phenylenediamine films. NANOSCALE RESEARCH LETTERS 2017; 12:594. [PMID: 29138950 PMCID: PMC5686037 DOI: 10.1186/s11671-017-2353-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2016] [Accepted: 10/25/2017] [Indexed: 05/30/2023]
Abstract
In this work, we studied the conditions of deposition of a semipermeable polyphenylenediamine (PPD)-based membrane on amperometric disk platinum electrodes. Restricting an access of interfering substances to the electrode surface, the membrane prevents their impact on the sensor operation. Two methods of membrane deposition by electropolymerization were compared-at varying potential (cyclic voltammetry) and at constant potential. The cyclic voltammetry was shown to be easier in performing and providing better properties of the membrane. The dependence of PPD membrane effectiveness on the number of cyclic voltammograms and phenylenediamine concentration was analyzed. It was shown that the impact of interfering substances (ascorbic acid, dopamine, cysteine, uric acid) on sensor operation could be completely avoided using three cyclic voltammograms in 30 mM phenylenediamine. On the other hand, when working with diluted samples, i.e., at lower concentrations of electroactive substances, it is reasonable to decrease the phenylenediamine concentration to 5 mM, which would result in a higher sensitivity of transducers to hydrogen peroxide due to a thinner PPD layer. The PPD membrane was tested during continuous operation and at 8-day storage and turned out to be efficient in sensor and biosensors.
Collapse
Affiliation(s)
- O. V. Soldatkina
- Taras Shevchenko National University of Kyiv, Volodymyrska Street 64, Kyiv, 01601 Ukraine
| | - I. S. Kucherenko
- Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, Zabolotnogo Street 150, Kyiv, 03148 Ukraine
| | - V. M. Pyeshkova
- Taras Shevchenko National University of Kyiv, Volodymyrska Street 64, Kyiv, 01601 Ukraine
- Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, Zabolotnogo Street 150, Kyiv, 03148 Ukraine
| | - S. A. Alekseev
- Taras Shevchenko National University of Kyiv, Volodymyrska Street 64, Kyiv, 01601 Ukraine
| | - O. O. Soldatkin
- Taras Shevchenko National University of Kyiv, Volodymyrska Street 64, Kyiv, 01601 Ukraine
- Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, Zabolotnogo Street 150, Kyiv, 03148 Ukraine
| | - S. V. Dzyadevych
- Taras Shevchenko National University of Kyiv, Volodymyrska Street 64, Kyiv, 01601 Ukraine
- Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine, Zabolotnogo Street 150, Kyiv, 03148 Ukraine
| |
Collapse
|
22
|
Kulkarni T, Slaughter G. Application of Semipermeable Membranes in Glucose Biosensing. MEMBRANES 2016; 6:membranes6040055. [PMID: 27983630 PMCID: PMC5192411 DOI: 10.3390/membranes6040055] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2016] [Revised: 11/27/2016] [Accepted: 12/08/2016] [Indexed: 02/07/2023]
Abstract
Glucose biosensors have received significant attention in recent years due to the escalating mortality rate of diabetes mellitus. Although there is currently no cure for diabetes mellitus, individuals living with diabetes can lead a normal life by maintaining tight control of their blood glucose levels using glucose biosensors (e.g., glucometers). Current research in the field is focused on the optimization and improvement in the performance of glucose biosensors by employing a variety of glucose selective enzymes, mediators and semipermeable membranes to improve the electron transfer between the active center of the enzyme and the electrode substrate. Herein, we summarize the different semipermeable membranes used in the fabrication of the glucose biosensor, that result in improved biosensor sensitivity, selectivity, dynamic range, response time and stability.
Collapse
Affiliation(s)
- Tanmay Kulkarni
- Bioelectronics Laboratory, Department of Computer Science and Electrical Engineering, University of Maryland Baltimore County, 1000 Hilltop Circle, Baltimore, MD 21250, USA.
| | - Gymama Slaughter
- Bioelectronics Laboratory, Department of Computer Science and Electrical Engineering, University of Maryland Baltimore County, 1000 Hilltop Circle, Baltimore, MD 21250, USA.
| |
Collapse
|
23
|
Weltin A, Kieninger J, Urban GA. Microfabricated, amperometric, enzyme-based biosensors for in vivo applications. Anal Bioanal Chem 2016; 408:4503-21. [PMID: 26935934 PMCID: PMC4909808 DOI: 10.1007/s00216-016-9420-4] [Citation(s) in RCA: 73] [Impact Index Per Article: 9.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2015] [Revised: 02/08/2016] [Accepted: 02/12/2016] [Indexed: 01/19/2023]
Abstract
Miniaturized electrochemical in vivo biosensors allow the measurement of fast extracellular dynamics of neurotransmitter and energy metabolism directly in the tissue. Enzyme-based amperometric biosensing is characterized by high specificity and precision as well as high spatial and temporal resolution. Aside from glucose monitoring, many systems have been introduced mainly for application in the central nervous system in animal models. We compare the microsensor principle with other methods applied in biomedical research to show advantages and drawbacks. Electrochemical sensor systems are easily miniaturized and fabricated by microtechnology processes. We review different microfabrication approaches for in vivo sensor platforms, ranging from simple modified wires and fibres to fully microfabricated systems on silicon, ceramic or polymer substrates. The various immobilization methods for the enzyme such as chemical cross-linking and entrapment in polymer membranes are discussed. The resulting sensor performance is compared in detail. We also examine different concepts to reject interfering substances by additional membranes, aspects of instrumentation and biocompatibility. Practical considerations are elaborated, and conclusions for future developments are presented. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Andreas Weltin
- Laboratory for Sensors, Department of Microsystems Engineering – IMTEK, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany
| | - Jochen Kieninger
- Laboratory for Sensors, Department of Microsystems Engineering – IMTEK, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany
| | - Gerald A. Urban
- Laboratory for Sensors, Department of Microsystems Engineering – IMTEK, University of Freiburg, Georges-Köhler-Allee 103, 79110 Freiburg, Germany
| |
Collapse
|
24
|
Silicon/SU8 multi-electrode micro-needle for in vivo neurochemical monitoring. Biosens Bioelectron 2015; 72:148-55. [DOI: 10.1016/j.bios.2015.05.004] [Citation(s) in RCA: 42] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2015] [Accepted: 05/05/2015] [Indexed: 11/23/2022]
|
25
|
Çelik AC, Öztürk F, Erden PE, Kaçar C, Kılıç E. Amperometric Lactate Biosensor Based on Carbon Paste Electrode Modified with Benzo[c]cinnoline and Multiwalled Carbon Nanotubes. ELECTROANAL 2015. [DOI: 10.1002/elan.201500180] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
26
|
Biocompatible xanthan/polypyrrole scaffolds for tissue engineering. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2015; 52:121-8. [PMID: 25953548 DOI: 10.1016/j.msec.2015.03.023] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2014] [Revised: 02/16/2015] [Accepted: 03/20/2015] [Indexed: 12/24/2022]
Abstract
Polypyrrole (PPy) was electropolymerized in xanthan hydrogels (XCA), resulting in electroactive XCAPPy scaffolds with (15 ± 3) wt.% PPy and (40 ± 10) μm thick. The physicochemical characterization of hybrid XCAPPy scaffolds was performed by means of cyclic voltammetry, swelling tests, Fourier transform infrared spectroscopy (FTIR), differential scanning calorimetry (DSC), thermogravimetric analyses (TGA), scanning electron microscopy (SEM), atomic force microscopy (AFM) and tensile tests. XCAPPy swelled~80% less than XCA. FTIR spectra and thermal analyses did not evidence strong interaction between PPy and XCA matrix. XCAPPy presented a porous stratified structure resulting from the arrangement of PPy chains parallel to XCA surface. Under stress XCAPPy presented larger strain than neat XCA probably due to the sliding of planar PPy chains. The adhesion and proliferation of fibroblasts onto XCA and XCAPPy were evaluated in the absence and in the presence of external magnetic field (EMF) of 0.4T, after one day, 7 days, 14 days and 21 days. Fibroblast proliferation was more pronounced onto XCAPPy than onto XCA, due to its higher hydrophobicity and surface roughness. EMF stimulated cell proliferation onto both scaffolds.
Collapse
|
27
|
Medina-Ceja L, Pardo-Peña K, Morales-Villagrán A, Ortega-Ibarra J, López-Pérez S. Increase in the extracellular glutamate level during seizures and electrical stimulation determined using a high temporal resolution technique. BMC Neurosci 2015; 16:11. [PMID: 25887152 PMCID: PMC4363345 DOI: 10.1186/s12868-015-0147-5] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2014] [Accepted: 02/20/2015] [Indexed: 12/21/2022] Open
Abstract
Background Glutamate has been measured using different methods to determine its role under normal and pathological conditions. Although microdialysis coupled with HPLC is the preferred method to study glutamate, this technique exhibits poor temporal resolution and is time consuming. The concentration of glutamate in dialysis samples can be measured via glutamate oxidase using the Amplex Red method. Methods A new device has been designed and constructed to rapidly deposit dialysis samples onto a polycarbonate plate at Cartesian coordinates (every five seconds). The samples were added to an enzymatic reaction that generates hydrogen peroxide from glutamate, which was quantified using fluorescence detection. Fluorescence emission was induced by laser excitation, stimulating each spot automatically, in addition to controlling the humidity, temperature and incubation time of the enzymatic reaction. Results The measurement of standard glutamate concentrations was linear and could be performed in dialysis samples. This approach was used to determine the effect of the convulsant drugs bicuculline and 4-aminopyridine on the extracellular glutamate concentration. Seizure activity was associated with a considerable increase in glutamate that correlated with altered EEG patterns for both drugs. Conclusions These results indicate that this method is able to read samples with high temporal resolution, and it is easy to use compared with classical methods such as high-performance liquid chromatography, with the advantage that a large number of samples can be measured in a single experimental series. This method provides an alternative approach to determine the concentrations of neurotransmitters or other compounds that generate hydrogen peroxide as a reaction product.
Collapse
Affiliation(s)
- Laura Medina-Ceja
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico.
| | - Kenia Pardo-Peña
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico.
| | - Alberto Morales-Villagrán
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico. .,Laboratorio de Neurofisiología y Neuroquímica, Departamento de Biología Celular y Molecular, Centro Universitario de Ciencias Biológicas y Agropecuarias, Universidad de Guadalajara, Camino Ing. R. Padilla Sánchez 2100, Las Agujas, Nextipac, CP 45110, Zapopan, Jalisco, Mexico.
| | - Jorge Ortega-Ibarra
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico.
| | - Silvia López-Pérez
- Laboratory of Neurophysiology and Neurochemistry, Department of Cellular and Molecular Biology, CUCBA, University of Guadalajara, Jalisco, Mexico.
| |
Collapse
|
28
|
Soldatkin O, Nazarova A, Krisanova N, Borуsov A, Kucherenko D, Kucherenko I, Pozdnyakova N, Soldatkin A, Borisova T. Monitoring of the velocity of high-affinity glutamate uptake by isolated brain nerve terminals using amperometric glutamate biosensor. Talanta 2014; 135:67-74. [PMID: 25640127 DOI: 10.1016/j.talanta.2014.12.031] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2014] [Revised: 12/17/2014] [Accepted: 12/21/2014] [Indexed: 10/24/2022]
Abstract
Glutamate is the major excitatory neurotransmitter in the central nervous system, which is involved in the main aspects of normal brain functioning. High-affinity Na(+)-dependent glutamate transporters is key proteins, which transport extracellular glutamate to the cytoplasm of nerve cells, thereby preventing continuous activation of glutamate receptors, and thus the development of neurotoxicity. Disturbance in glutamate uptake is involved in the pathogenesis of major neurological disorders. Amperometric biosensors are the most promising and successful among electrochemical biosensors. In this study, we developed (1) amperometric glutamate biosensor, (2) methodological approach for the analysis of glutamate uptake in liquid samples of isolated rat brain nerve terminals (synaptosomes). The basal level of glutamate, the initial velocity of glutamate uptake and time-dependent accumulation of glutamate by synaptosomes were determined using developed glutamate biosensor. Comparative analysis of the data with those obtained by radioactive analysis, spectrofluorimetry and ion exchange chromatography was performed. Therefore, the methodological approach for monitoring of the velocity of glutamate uptake, which takes into consideration the definite level of endogenous glutamate in nerve terminals, was developed using glutamate biosensor.
Collapse
Affiliation(s)
- O Soldatkin
- Laboratory of Biomolecular Electronics, Department of Translation Mechanisms of Genetic Information, Institute of Molecular Biology and Genetics, NAS of Ukraine, 150 Zabolotnogo Str., Kyiv 03680, Ukraine.
| | - A Nazarova
- The Department of Neurochemistry, Palladin Institute of Biochemistry, NAS of Ukraine, 9 Leontovicha Street, Kyiv 01601, Ukraine
| | - N Krisanova
- The Department of Neurochemistry, Palladin Institute of Biochemistry, NAS of Ukraine, 9 Leontovicha Street, Kyiv 01601, Ukraine
| | - A Borуsov
- The Department of Neurochemistry, Palladin Institute of Biochemistry, NAS of Ukraine, 9 Leontovicha Street, Kyiv 01601, Ukraine
| | - D Kucherenko
- Institute of High Technologies, Taras Shevchenko National University of Kyiv, 64, Volodymyrska Str., Kyiv 01003, Ukraine
| | - I Kucherenko
- Laboratory of Biomolecular Electronics, Department of Translation Mechanisms of Genetic Information, Institute of Molecular Biology and Genetics, NAS of Ukraine, 150 Zabolotnogo Str., Kyiv 03680, Ukraine
| | - N Pozdnyakova
- The Department of Neurochemistry, Palladin Institute of Biochemistry, NAS of Ukraine, 9 Leontovicha Street, Kyiv 01601, Ukraine
| | - A Soldatkin
- Laboratory of Biomolecular Electronics, Department of Translation Mechanisms of Genetic Information, Institute of Molecular Biology and Genetics, NAS of Ukraine, 150 Zabolotnogo Str., Kyiv 03680, Ukraine; Institute of High Technologies, Taras Shevchenko National University of Kyiv, 64, Volodymyrska Str., Kyiv 01003, Ukraine
| | - T Borisova
- The Department of Neurochemistry, Palladin Institute of Biochemistry, NAS of Ukraine, 9 Leontovicha Street, Kyiv 01601, Ukraine
| |
Collapse
|
29
|
Kucherenko IS, Didukh DY, Soldatkin OO, Soldatkin AP. Amperometric biosensor system for simultaneous determination of adenosine-5'-triphosphate and glucose. Anal Chem 2014; 86:5455-62. [PMID: 24810180 DOI: 10.1021/ac5006553] [Citation(s) in RCA: 34] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
The majority of biosensors for adenosine-5'-triphosphate (ATP) determination are based on cascades of enzymatic reactions; therefore, they are sensitive to glucose or glycerol (depending on the enzymatic system) as well as to ATP. The presence of unknown concentrations of these substances in the sample greatly complicates the determination of ATP. To overcome this disadvantage of known biosensors, we developed a biosensor system consisting of two biosensors: the first one is based on glucose oxidase and is intended for measuring glucose concentration, and the second one is based on glucose oxidase and hexokinase and is sensitive toward both glucose and ATP. Using glucose concentration measured by the first biosensor, we can analyze the total response to glucose and ATP obtained by the second biosensor. Platinum disc electrodes were used as amperometric transducers. The polyphenilenediamine membrane was deposited onto the surface of platinum electrodes to avoid the response to electroactive substances. The effect of glucose concentration on biosensor determination of ATP was studied. The reproducibility of biosensor responses to glucose and ATP during a day was tested (relative standard deviation, RSD, of responses to glucose was 3-6% and to ATP was 8-12%) as well as storage stability of the biosensors (no decrease of glucose responses and 43% drop of ATP responses during 50 days). The measurements of ATP and glucose in pharmaceutical vials (including mixtures of ATP and glucose) were carried out. It was shown that the developed biosensor system can be used for simultaneous analysis of glucose and ATP concentrations in water solutions.
Collapse
Affiliation(s)
- Ivan S Kucherenko
- Laboratory of Biomolecular Electronics, Institute of Molecular Biology and Genetics of National Academy of Sciences of Ukraine , 150 Zabolotny Str., Kyiv, 03680, Ukraine
| | | | | | | |
Collapse
|
30
|
Vagin MY, Sekretaryova AN, Reategui RS, Lundstrom I, Winquist F, Eriksson M. Arrays of Screen-Printed Graphite Microband Electrodes as a Versatile Electroanalysis Platform. ChemElectroChem 2014. [DOI: 10.1002/celc.201300204] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
31
|
Rocchitta G, Secchi O, Alvau MD, Farina D, Bazzu G, Calia G, Migheli R, Desole MS, O'Neill RD, Serra PA. Simultaneous telemetric monitoring of brain glucose and lactate and motion in freely moving rats. Anal Chem 2013; 85:10282-8. [PMID: 24102201 DOI: 10.1021/ac402071w] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022]
Abstract
A new telemetry system for simultaneous detection of extracellular brain glucose and lactate and motion is presented. The device consists of dual-channel, single-supply miniature potentiostat-I/V converter, a microcontroller unit, a signal transmitter, and a miniaturized microvibration sensor. Although based on simple and inexpensive components, the biotelemetry device has been used for accurate transduction of the anodic oxidation currents generated on the surface of implanted glucose and lactate biosensors and animal microvibrations. The device was characterized and validated in vitro before in vivo experiments. The biosensors were implanted in the striatum of freely moving animals and the biotelemetric device was fixed to the animal's head. Physiological and pharmacological stimulations were given in order to induce striatal neural activation and to modify the motor behavior in awake, untethered animals.
Collapse
Affiliation(s)
- Gaia Rocchitta
- Department of Clinical and Experimental Medicine, Medical School, University of Sassari , Viale S. Pietro 43/b, 07100 Sassari, Italy
| | | | | | | | | | | | | | | | | | | |
Collapse
|
32
|
Antonio JL, Lira LM, Gonçales VR, Cordoba de Torresi SI. Fully conducting hydro-sponges with electro-swelling properties tuned by synthetic parameters. Electrochim Acta 2013. [DOI: 10.1016/j.electacta.2012.11.012] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
33
|
Preparation and electrical sensitive behavior of poly (N-vinylpyrrolidone-co-acrylic acid) hydrogel with flexible chain nature. Eur Polym J 2013. [DOI: 10.1016/j.eurpolymj.2013.04.022] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
|
34
|
Soldatkin AP, Dzyadevych SV, Korpan YI, Sergeyeva TA, Arkhypova VN, Biloivan OA, Soldatkin OO, Shkotova LV, Zinchenko OA, Peshkova VM, Saiapina OY, Marchenko SV, El'skaya AV. Biosensors. A quarter of a century of R&D experience. ACTA ACUST UNITED AC 2013. [DOI: 10.7124/bc.000819] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Affiliation(s)
- A. P. Soldatkin
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - S. V. Dzyadevych
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - Y. I. Korpan
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - T. A. Sergeyeva
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - V. N. Arkhypova
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - O. A. Biloivan
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - O. O. Soldatkin
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - L. V. Shkotova
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - O. A. Zinchenko
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - V. M. Peshkova
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - O. Y. Saiapina
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - S. V. Marchenko
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| | - A. V. El'skaya
- Institute of Molecular Biology and Genetics, National Academy of Sciences of Ukraine
| |
Collapse
|
35
|
|
36
|
A New Trend on Biosensor for Neurotransmitter Choline/Acetylcholine—an Overview. Appl Biochem Biotechnol 2013; 169:1927-39. [DOI: 10.1007/s12010-013-0099-0] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2012] [Accepted: 01/10/2013] [Indexed: 11/27/2022]
|
37
|
Pemberton RM, Cox T, Tuffin R, Sage I, Drago GA, Biddle N, Griffiths J, Pittson R, Johnson G, Xu J, Jackson SK, Kenna G, Luxton R, Hart JP. Microfabricated glucose biosensor for culture well operation. Biosens Bioelectron 2012; 42:668-77. [PMID: 23265827 DOI: 10.1016/j.bios.2012.11.032] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2012] [Revised: 06/26/2012] [Accepted: 11/26/2012] [Indexed: 11/17/2022]
Abstract
A water-based carbon screen-printing ink formulation, containing the redox mediator cobalt phthalocyanine (CoPC) and the enzyme glucose oxidase (GOx), was investigated for its suitability to fabricate glucose microbiosensors in a 96-well microplate format: (1) the biosensor ink was dip-coated onto a platinum (Pt) wire electrode, leading to satisfactory amperometric performance; (2) the ink was deposited onto the surface of a series of Pt microelectrodes (10-500 μm diameter) fabricated on a silicon substrate using MEMS (microelectromechanical systems) microfabrication techniques: capillary deposition proved to be successful; a Pt microdisc electrode of ≥100 μm was required for optimum biosensor performance; (3) MEMS processing was used to fabricate suitably sized metal (Pt) tracks and pads onto a silicon 96 well format base chip, and the glucose biosensor ink was screen-printed onto these pads to create glucose microbiosensors. When formed into microwells, using a 340 μl volume of buffer, the microbiosensors produced steady-state amperometric responses which showed linearity up to 5 mM glucose (CV=6% for n=5 biosensors). When coated, using an optimised protocol, with collagen in order to aid cell adhesion, the biosensors continued to show satisfactory performance in culture medium (linear range to 2 mM, dynamic range to 7 mM, CV=5.7% for n=4 biosensors). Finally, the operation of these collagen-coated microbiosensors, in 5-well 96-well format microwells, was tested using a 5-channel multipotentiostat. A relationship between amperometric response due to glucose, and cell number in the microwells, was observed. These results indicate that microphotolithography and screen-printing techniques can be combined successfully to produce microbiosensors capable of monitoring glucose metabolism in 96 well format cell cultures. The potential application areas for these microbiosensors are discussed.
Collapse
Affiliation(s)
- R M Pemberton
- Centre for Research in Biosciences, Faculty of Health and Life Sciences, University of the West of England, Bristol, UK
| | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
38
|
Mohd Zain Z, Ab Ghani S, O’Neill RD. Amperometric microbiosensor as an alternative tool for investigation of d-serine in brain. Amino Acids 2012; 43:1887-94. [DOI: 10.1007/s00726-012-1365-0] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2012] [Accepted: 07/06/2012] [Indexed: 12/23/2022]
|
39
|
Lamberti F, Luni C, Zambon A, Andrea Serra P, Giomo M, Elvassore N. Flow biosensing and sampling in indirect electrochemical detection. BIOMICROFLUIDICS 2012; 6:24114-2411413. [PMID: 22655022 PMCID: PMC3360726 DOI: 10.1063/1.4705368] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2012] [Accepted: 04/05/2012] [Indexed: 05/30/2023]
Abstract
Miniaturization in biological analyses has several advantages, such as sample volume reduction and fast response time. The integration of miniaturized biosensors within lab-on-a-chip setups under flow conditions is highly desirable, not only because it simplifies process handling but also because measurements become more robust and operator-independent. In this work, we study the integration of flow amperometric biosensors within a microfluidic platform when analyte concentration is indirectly measured. As a case study, we used a platinum miniaturized glucose biosensor, where glucose is enzymatically converted to [Formula: see text] that is oxidized at the electrode. The experimental results produced are strongly coupled to a theoretical analysis of fluid dynamic conditions affecting the electrochemical response of the sensor. We verified that the choice of the inlet flow rate is a critical parameter in flow biosensors, because it affects both glucose and [Formula: see text] transport, to and from the electrode. We identify optimal flow rate conditions for accurate sensing at high time resolution. A dimensionless theoretical analysis allows the extension of the results to other sensing systems according to fluid dynamic similarity principles. Furthermore, we developed a microfluidic design that connects a sampling unit to the biosensor, in order to decouple the sampling flow rate from that of the actual measurement.
Collapse
|
40
|
Prună A, Brânzoi F. Electrochemical activity and microscopy of electrosynthesised poly(o-phenylenediamine) nanotubes. JOURNAL OF POLYMER RESEARCH 2012. [DOI: 10.1007/s10965-012-9879-4] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
41
|
Wahono N, Qin S, Oomen P, Cremers TIF, de Vries MG, Westerink BHC. Evaluation of permselective membranes for optimization of intracerebral amperometric glutamate biosensors. Biosens Bioelectron 2012; 33:260-6. [PMID: 22326702 DOI: 10.1016/j.bios.2012.01.019] [Citation(s) in RCA: 32] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2011] [Revised: 01/16/2012] [Accepted: 01/17/2012] [Indexed: 01/01/2023]
Abstract
Monitoring of extracellular brain glutamate concentrations by intracerebral biosensors is a promising approach to further investigate the role of this important neurotransmitter. However, amperometric biosensors are typically hampered by Faradaic interference caused by the presence of other electroactive species in the brain, such as ascorbic acid, dopamine, and uric acid. Various permselective membranes are often used on biosensors to prevent this. In this study we evaluated the most commonly used membranes, i.e. nafion, polyphenylenediamine, polypyrrole, polyaniline, and polynaphthol using a novel silica-based platinum electrode. First we selected the membranes with the highest sensitivity for hydrogen peroxide in vitro and an optimal selectivity against electrochemical interferents. Then we evaluated the performances of these membranes in a short lasting (3-4h) in vivo experiment. We found that best in vitro performance was accomplished with biosensors that were protected by a poly(m-phenylenediamine) membrane deposited onto the platinum electrode by cyclic voltammetry. However, post-implantation evaluation of these membranes showed poor selectivity against dopamine. Combination with a previously applied nafion layer did not protect the sensors against acute biofouling; indeed it was even counter effective. Finally, we investigated the ability of our biosensors to monitor the effect of glutamate transport blocker DL-TBOA on modulating glutamate concentrations in the prefrontal cortex of anaesthetized rats. The optimized biosensors recorded a rapid 35-fold increase in extracellular glutamate, and are considered suitable for further exploration in vivo.
Collapse
Affiliation(s)
- N Wahono
- Biomonitoring and Sensoring Group, Groningen University, The Netherlands.
| | | | | | | | | | | |
Collapse
|
42
|
H. Takahashi S, M. Lira L, I. Córdoba de Torresi S. Zero-Order Release Profiles from A Multistimuli Responsive Electro-Conductive Hydrogel. ACTA ACUST UNITED AC 2012. [DOI: 10.4236/jbnb.2012.322032] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
43
|
HAYASHI T, SAKURADA I, HONDA K, MOTOHASHI S, UCHIKURA K. Electrochemical Detection of Sugar-related Compounds Using Boron-doped Diamond Electrodes. ANAL SCI 2012; 28:127-33. [DOI: 10.2116/analsci.28.127] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Affiliation(s)
| | | | - Kensuke HONDA
- Department of Biological Science and Chemistry, Faculty of Science, Yamaguchi University
| | | | | |
Collapse
|
44
|
Modulation of fibroblast inflammatory response by surface modification of a perfluorinated ionomer. Biointerphases 2011; 6:43-53. [PMID: 21721839 DOI: 10.1116/1.3583535] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
An ideal surface for implantable glucose sensors would be able to evade the events leading to chronic inflammation and fibrosis, thereby extending its utility in an in vivo environment. Nafion™, a perfluorinated ionomer, is the membrane material preferred for in situ glucose sensors. Unfortunately, the surface properties of Nafion™ promote random protein adsorption and eventual foreign body encapsulation, thus leading to loss of glucose signal over time. Details of the techniques to render Nafion™ nonprotein fouling are given in a previous article [T. I. Valdes et al., Biomaterials 29, 1356 (2008)]. Once random protein adsorption is prevented, a biologically active peptide can be covalently bonded to the treated Nafion™ to induce cellular adhesion. Cellular responses to these novel decorated Nafion™ surfaces are detailed here, including cell viability, cell spreading, and type I collagen synthesis. Normal human dermal fibroblasts (NHDFs) were cultured on control and modified Nafion™ surfaces. Findings indicate that Nafion™ modified with 10% 2-hydroxyethyl methacrylate and 90% tetraglyme created a nonfouling surface that was subsequently decorated with the YRGDS peptide. NHDFs were shown to have exhibited decreased type I collagen production in comparison to NHDF cells on unmodified Nafion™ surfaces. Here, the authors report evidence that proves that optimizing conditions to prevent protein adsorption and enhance cellular adhesion may eliminate fibrous encapsulation of an implant.
Collapse
|
45
|
Mediator-less highly sensitive voltammetric detection of glutamate using glutamate dehydrogenase/vertically aligned CNTs grown on silicon substrate. Biosens Bioelectron 2011; 31:110-5. [PMID: 22040749 DOI: 10.1016/j.bios.2011.10.002] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2011] [Revised: 09/12/2011] [Accepted: 10/03/2011] [Indexed: 11/20/2022]
Abstract
A sensitive glutamate biosensor is prepared based on glutamate dehydrogenase/vertically aligned carbon nanotubes (GLDH, VACNTs). Vertically aligned carbon nanotubes were grown on a silicon substrate by direct current plasma enhanced chemical vapor deposition (DC-PECVD) method. The electrochemical behavior of the synthesized VACNTs was investigated by cyclic voltammetry and electrochemical impedance spectroscopic methods. Glutamate dehydrogenase covalently attached on tip of VACNTs. The electrochemical performance of the electrode for detection of glutamate was investigated by cyclic and differential pulse voltammetry. Differential pulse voltammetric determinations of glutamate are performed in mediator-less condition and also, in the presence of 1 and 5 μM thionine as electron mediator. The linear calibration curve of the concentration of glutamate versus peak current is investigated in a wide range of 0.1-500 μM. The mediator-less biosensor has a low detection limit of 57 nM and two linear ranges of 0.1-20 μM with a sensitivity of 0.976 mA mM(-1) cm(-2) and 20-300 μM with a sensitivity of 0.182 mA mM(-1) cm(-2). In the presence of 1 μM thionine as an electron mediator, the prepared biosensor shows a low detection limit of 68 nM and two linear ranges of 0.1-20 with a calibration sensitivity of 1.17 mA mM(-1) cm(-2) and 20-500 μM with a sensitivity of 0.153 mA mM(-1) cm(-2). The effects of the other biological compounds on the voltammetric behavior of the prepared biosensor and its response stability are investigated. The results are demonstrated that the GLDH/VACNTs electrode even without electron mediator is a suitable basic electrode for detection of glutamate.
Collapse
|
46
|
Frey O, van der Wal PD, Spieth S, Brett O, Seidl K, Paul O, Ruther P, Zengerle R, de Rooij NF. Biosensor microprobes with integrated microfluidic channels for bi-directional neurochemical interaction. J Neural Eng 2011; 8:066001. [DOI: 10.1088/1741-2560/8/6/066001] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
47
|
Vasylieva N, Barnych B, Meiller A, Maucler C, Pollegioni L, Lin JS, Barbier D, Marinesco S. Covalent enzyme immobilization by poly(ethylene glycol) diglycidyl ether (PEGDE) for microelectrode biosensor preparation. Biosens Bioelectron 2011; 26:3993-4000. [DOI: 10.1016/j.bios.2011.03.012] [Citation(s) in RCA: 98] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2011] [Revised: 03/04/2011] [Accepted: 03/11/2011] [Indexed: 11/26/2022]
|
48
|
Pereira AC, Kisner A, Tarley CRT, Kubota LT. Development of a Carbon Paste Electrode for Lactate Detection Based on Meldola’s Blue Adsorbed on Silica Gel Modified with Niobium Oxide and Lactate Oxidase. ELECTROANAL 2011. [DOI: 10.1002/elan.201000709] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
49
|
Rothwell SA, O'Neill RD. Effects of applied potential on the mass of non-conducting poly(ortho-phenylenediamine) electro-deposited on EQCM electrodes: comparison with biosensor selectivity parameters. Phys Chem Chem Phys 2011; 13:5413-21. [PMID: 21359356 DOI: 10.1039/c0cp02341h] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
An electrochemical quartz-crystal microbalance (EQCM) was used to determine the mass of poly-(o-phenylenediamine) (PoPD) layers electro-deposited at different applied potentials in neutral buffered monomer solution, conditions that produce the insulating form of the polymer used as a permselective membrane in biosensor applications. There was a systematic increase in the total, steady state PoPD mass deposited for fixed applied potentials from 0.05 to 0.6 V vs. SCE, followed by a plateau up to 0.8 V. Comparison of PoPD mass and permselectivity parameters indicates that the ability of the passivating form of PoPD to block interference species in biosensor applications is not related in a simple way to the mass of material deposited on the surface. Instead, effects of the applied electropolymerisation potential in driving the electro-oxidation of oPD dimers and oligomers formed during the electro-deposition process are likely to have a more direct impact on the selectivity characteristics of the PoPD layer. The results highlight the usefulness of apparent permeabilities, especially of ascorbic acid, in revealing differences between PoPD layers electro-deposited under different conditions.
Collapse
Affiliation(s)
- Sharon A Rothwell
- UCD School of Chemistry and Chemical Biology, University College Dublin, Belfield, Dublin 4, Ireland
| | | |
Collapse
|
50
|
Siontorou CG, Batzias FA. Innovation in biotechnology: moving from academic research to product development--the case of biosensors. Crit Rev Biotechnol 2010; 30:79-98. [PMID: 20214418 DOI: 10.3109/07388550903427298] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
The fast pace of technological change in the biotechnology industry and the market demands require continuous innovation, which, owing to the science base of the sector, derives from academic research through a transformation process that converts science-oriented knowledge to marketable products. There appear to be some inherent difficulties in transforming directly the knowledge output of academic research to industrial use. The purpose of this article is to examine certain transition mechanisms from monodisciplinary academic isolation (curiosity-driven and internal-worth innovation) to university-industry alliances (market-driven and public-worth innovation) through inter-organizational multidisciplinary collaboration and contextualize the analysis with the case of biosensors. While the majority of literature on the subject studies the channels of knowledge transfer as determinants of alliance success (transferor/transferee interactions), either from the university side (science base) or the industry side (market base), this article focuses on the transferable (technology base) and how it can be strategically modeled and managed by the industry to promote innovation. Based on the valuable lessons learnt from the biosensor paradigm, the authors argue that strategic industry choices deal primarily with the best stage/point to intersect and seize the university output, implanting the required element of marketability that will transform an idea to a viable application. The authors present a methodological approach for accelerating the knowledge transfer from the university to industry aiming at the effective transition of science to products through a business model reconfiguration.
Collapse
Affiliation(s)
- Christina G Siontorou
- Department of Industrial Management and Technology, University of Piraeus, Karaoli & Dimitriou 80, Piraeus, Greece.
| | | |
Collapse
|