1
|
Barzegar F, Kamankesh M, Mohammadi A. An efficient microchip electromembrane extraction online with high-performance liquid chromatography for the measurement of nicotine in high consumption vegetables. PHYTOCHEMICAL ANALYSIS : PCA 2024. [PMID: 39031170 DOI: 10.1002/pca.3418] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/13/2024] [Revised: 06/24/2024] [Accepted: 06/24/2024] [Indexed: 07/22/2024]
Abstract
INTRODUCTION Nicotine, a highly addictive substance, is naturally produced in the Solanaceae family of plants, particularly tobacco. The presence of nicotine in plant foods has adverse effects on the lungs, kidneys, heart, and reproductive system. OBJECTIVE A novel three-phase microchip flat electromembrane coupled with online high-performance liquid chromatography (HPLC) was developed to analyze nicotine in tomato, mushroom, eggplant, bell pepper, and red pepper. METHODS The microchip was connected to the HPLC in online mode. All effective variables were optimized to achieve the best extraction response. The use of electric potential and 2-nitrophenyl octyl ether -5% di(2-ethylhexyl) phosphate as a modified supported liquid membrane (SLM) increased the sensitivity and selectivity. RESULTS The optimal extraction voltage, extraction time, and ion balance were 40 V, 10 min and 0, respectively. The dynamic linear range was 0.5-1000 ng g-1. The obtained recovery, relative standard deviation, and enrichment factor were 98%, 7%, and 35, respectively. The limits of detection 0.4 ng g-1 and the limits of quantification were obtained 1.3 ng g-1. The highest (105.0 ng g-1) and lowest (3.4 ng g-1) concentrations of nicotine were obtained for eggplant and tomato, respectively. CONCLUSION Selective electromembrane extraction of nicotine from the donor phase to the acceptor phase was performed by optimizing the main variables influencing the method mechanism. The new channel design in this analytical system and online injection increased efficiency, stability, and repeatability. The results revealed that this method is capable for the efficient determination of trace amount of nicotine in edible vegetables.
Collapse
Affiliation(s)
- Fatemeh Barzegar
- Department of Food Science and Technology, Faculty of Nutrition Science, Food Science and Technology/National Nutrition and Food Technology Research Institute, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Marzieh Kamankesh
- Food Safety Research Center (salt), Semnan University of Medical Sciences, Semnan, Iran
- School of Pharmacy, Semnan University of Medical Sciences, Semnan, Iran
| | - Abdorreza Mohammadi
- Department of Food Science and Technology, Faculty of Nutrition Science, Food Science and Technology/National Nutrition and Food Technology Research Institute, Shahid Beheshti University of Medical Sciences, Tehran, Iran
- Food Safety Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
2
|
Martín A, Santigosa E, Ramos-Payán M. Green strategies using solvent-free biodegradable membranes in microfluidic devices. Liquid phase microextraction and electromembrane extraction. Anal Chim Acta 2023; 1274:341572. [PMID: 37455082 DOI: 10.1016/j.aca.2023.341572] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 05/22/2023] [Accepted: 06/28/2023] [Indexed: 07/18/2023]
Abstract
In this work, a novel solvent-free microfluidic method based liquid phase microextraction has been proposed for the first time. A comprehensive study of liquid phase microextraction (LPME) and electromembrane extraction (EME) implemented in microfluidic formats has been carried out to investigate the efficiency of biodegradable membranes (such as agarose) without organic solvent to develop fully environmental microfluidic methods. For this study, non-polar and polar basic compounds (five) were selected as model analytes and different agarose membrane compositions were synthesized and tested with and without organic solvent (solvent-free). Under optimal experimental conditions, the extraction efficiencies obtained using solvent-free LPME-chip devices were similar to the ones obtained using solvent-free EME-chip devices at very low voltages (0.25 V), however, LPME microfluidic format was selected due to its simplicity. The proposed green microfluidic device was successfully applied in urine samples with recoveries between 80 and 93% for all analytes and relative standard deviation below 7% for all analytes. Results were compared with experiments previously conducted using conventional (polypropylene) membranes, observing that solvent-free microfluidic systems based on biodegradable solid support materials have proven to be an attractive alternative and offered the same advantages in terms of membrane stability allowing consecutive extractions compared to supported liquid membranes (SLM) microfluidic methods.
Collapse
Affiliation(s)
- Alejandro Martín
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, C/Prof. García González s/n, 41012, Seville, Spain
| | - Elia Santigosa
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, C/Prof. García González s/n, 41012, Seville, Spain
| | - María Ramos-Payán
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, C/Prof. García González s/n, 41012, Seville, Spain.
| |
Collapse
|
3
|
Hadavi D, Tosheva I, Siegel TP, Cuypers E, Honing M. Technological advances for analyzing the content of organ-on-a-chip by mass spectrometry. Front Bioeng Biotechnol 2023; 11:1197760. [PMID: 37284240 PMCID: PMC10239923 DOI: 10.3389/fbioe.2023.1197760] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2023] [Accepted: 05/05/2023] [Indexed: 06/08/2023] Open
Abstract
Three-dimensional (3D) cell cultures, including organ-on-a-chip (OOC) devices, offer the possibility to mimic human physiology conditions better than 2D models. The organ-on-a-chip devices have a wide range of applications, including mechanical studies, functional validation, and toxicology investigations. Despite many advances in this field, the major challenge with the use of organ-on-a-chips relies on the lack of online analysis methods preventing the real-time observation of cultured cells. Mass spectrometry is a promising analytical technique for real-time analysis of cell excretes from organ-on-a-chip models. This is due to its high sensitivity, selectivity, and ability to tentatively identify a large variety of unknown compounds, ranging from metabolites, lipids, and peptides to proteins. However, the hyphenation of organ-on-a-chip with MS is largely hampered by the nature of the media used, and the presence of nonvolatile buffers. This in turn stalls the straightforward and online connection of organ-on-a-chip outlet to MS. To overcome this challenge, multiple advances have been made to pre-treat samples right after organ-on-a-chip and just before MS. In this review, we summarised these technological advances and exhaustively evaluated their benefits and shortcomings for successful hyphenation of organ-on-a-chip with MS.
Collapse
|
4
|
Martín A, Fernández-Torres R, Bello-López MÁ, Ramos-Payán M. An improved microfluidic device to enhance the enrichment factors in liquid phase microextraction: application to the simultaneous extraction of polar and non-polar acids in biological samples. Mikrochim Acta 2023; 190:170. [PMID: 37016169 PMCID: PMC10073048 DOI: 10.1007/s00604-023-05752-9] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2023] [Accepted: 03/15/2023] [Indexed: 04/06/2023]
Abstract
A new microfluidic device to enhance the enrichment factor in miniaturized systems is proposed. The microfluidic system was design for liquid phase microextractions, and it was applied to the simultaneous extraction of acidic compounds of a wide range of polarity (0.5 < log P < 3). The device operated under stagnant acceptor phase conditions and all the operational parameters involved were optimized. Tributyl phosphate was found to be a new highly efficient supported liquid membrane to simultaneously extract analytes of very different polarities. The optimal donor and acceptor phase were pH 2 and pH 13, respectively. The donor flow rate and the extraction time were investigated simultaneously, offering great versatility with high enrichment factors (EFs). Limits of quantitation were within 0.02 and 0.09 µg mL-1 for all compounds at 10 µL min-1 as donor flow rate and 20-min extractions, offering EFs between 11 and 18 with only 200-µL sample volume consumption. The method was successfully applied to human urine samples, observing recoveries between 47 and 90% for all compounds. This new proposed microfluidic system increases the wide range of applications, especially when the analytes are present in lower concentrations in the sample.
Collapse
Affiliation(s)
- Alejandro Martín
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, C/Prof., García González S/N, 41012, Seville, Spain
| | - Rut Fernández-Torres
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, C/Prof., García González S/N, 41012, Seville, Spain
| | - Miguel Ángel Bello-López
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, C/Prof., García González S/N, 41012, Seville, Spain
| | - María Ramos-Payán
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, C/Prof., García González S/N, 41012, Seville, Spain.
| |
Collapse
|
5
|
Zarghampour F, Yamini Y, Alipanahpour Dil E, Shokrollahi A, Javadian G. A new microfluidic-chip device followed by sensitive image analysis of smart phone for simultaneous determination of dyes with different acidic-basic properties. Talanta 2023; 254:124168. [PMID: 36549133 DOI: 10.1016/j.talanta.2022.124168] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2022] [Revised: 12/01/2022] [Accepted: 12/02/2022] [Indexed: 12/13/2022]
Abstract
In this study, a new microfluidic-chip coupled with micro solid phase extraction (μ-SPE) and a RGB detection system was designed. The method was used for extraction and simultaneous determination of trace amounts of dyes with different acidic-basic properties. Erythrosine (Ery) and Crystal Violet (CV) were selected as acidic and basic model analytes, respectively. The first step of this method is based on the on-chip electromembrane extraction (CEME) of analytes from aqueous solution. The utilized microfluidic system is a single compartment that composed of three polymethyl metacrylate plates (with sandwiched structures) patterned with palm shaped helix channels. The device consisted one pair of platinum electrodes that were embedded in the acceptor phase channels in each side. The middle part was cut and used as the path of the sample. The extracted analytes by CEME were passed through the micro-packed column containing strong cation and anion exchanger sorbents respectively. Two adsorbents were separated by a polypropylene frit and sealed on each side by two polypropylene frites. Following dye adsorption on the sorbents, the colors that emerged were promptly evaluated using RGB colorimetry on a smartphone. Central composite design was used to analyze and optimize the effective parameters on extraction efficiency. The relative standard deviations (RSDs%) based on five replicate measurements were less than 7.8% for RGB and 8.6% for the spectrophotometry technique under ideal conditions. Image analysis using a smartphone yielded LOD values of 15.0 and 10.5 μg L-1 for Ery and CV, respectively. The CEME- μ-SPE -RGB approach produced findings that were equivalent to those obtained by spectrophotometry. Finally, the approach was used to accurately determine Ery and CV in water samples, yielding good relative recoveries (recovery ≥94.0).
Collapse
Affiliation(s)
- Fereshteh Zarghampour
- Iranian National Standardization Organization, General Bureau of Standard Kohgiluyeh and Boyer-Ahmad Province, Yasouj, 75916-53631, Iran
| | - Yadollah Yamini
- Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, P.O. Box: 14115-175, Tehran, Iran.
| | | | | | - Ghazal Javadian
- Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, P.O. Box: 14115-175, Tehran, Iran
| |
Collapse
|
6
|
Ocaña-González JA, Aranda-Merino N, Pérez-Bernal JL, Ramos-Payán M. Solid supports and supported liquid membranes for different liquid phase microextraction and electromembrane extraction configurations. A review. J Chromatogr A 2023; 1691:463825. [PMID: 36731330 DOI: 10.1016/j.chroma.2023.463825] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2022] [Revised: 01/09/2023] [Accepted: 01/22/2023] [Indexed: 01/29/2023]
Abstract
Liquid phase microextraction (LPME) and electromembrane microextraction (EME) can be considered as two of the most popular techniques in sample treatment today. Both techniques can be configurated as membrane-assisted techniques to carry out the extraction. These supports provide the required geometry and stability on the contact surface between two phases (donor and acceptor) and improve the reproducibility of sample treatment techniques. These solid support pore space, once is filled with organic solvents, act as a selective barrier acting as a supported liquid membrane (SLM). The SLM nature is a fundamental parameter, and its selection is critical to carry out successful extractions. There are numerous SLMs that have been successfully employed in a wide variety of application fields. The latter is due to the specificity of the selected organic solvents, which allows the extraction of compounds of a very different nature. In the last decade, solid supports and SLM have evolved towards "green" and environmentally friendly materials and solvents. In this review, solid supports implemented in LPME and EME will be discussed and summarized, as well as their applications. Moreover, the advances and modifications of the solid supports and the SLMs to improve the extraction efficiencies, recoveries and enrichment factors are discussed. Hollow fiber and flat membranes, including microfluidic systems, will be considered depending on the technique, configuration, or device used.
Collapse
Affiliation(s)
- Juan Antonio Ocaña-González
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, c/Prof. García González s/n, 41012 Seville, Spain
| | - Noemí Aranda-Merino
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, c/Prof. García González s/n, 41012 Seville, Spain
| | - Juan Luis Pérez-Bernal
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, c/Prof. García González s/n, 41012 Seville, Spain
| | - María Ramos-Payán
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, c/Prof. García González s/n, 41012 Seville, Spain.
| |
Collapse
|
7
|
A green microfluidic method for the simultaneous extraction of polar and non-polar basic compounds in biological samples. Microchem J 2023. [DOI: 10.1016/j.microc.2023.108553] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/24/2023]
|
8
|
Santigosa E, Pedersen-Bjergaard S, Giménez-Gómez P, Muñoz M, Ramos-Payán M. A rapid and versatile microfluidic method for the simultaneous extraction of polar and non-polar basic pharmaceuticals from human urine. Anal Chim Acta 2022; 1208:339829. [DOI: 10.1016/j.aca.2022.339829] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Revised: 04/05/2022] [Accepted: 04/09/2022] [Indexed: 11/01/2022]
|
9
|
Eie LV, Pedersen-Bjergaard S, Hansen FA. Electromembrane extraction of polar substances - Status and perspectives. J Pharm Biomed Anal 2022; 207:114407. [PMID: 34634529 DOI: 10.1016/j.jpba.2021.114407] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Revised: 09/20/2021] [Accepted: 09/30/2021] [Indexed: 12/15/2022]
Abstract
In this article, the scientific literature on electromembrane extraction (EME) of polar substances (log P < 2) is reviewed. EME is an extraction technique based on electrokinetic migration of analyte ions from an aqueous sample, across an organic supported liquid membrane (SLM), and into an aqueous acceptor solution. Because extraction is based on voltage-assisted partitioning, EME is fundamentally suitable for extraction of polar and ionizable substances that are challenging in many other extraction techniques. The article provides an exhaustive overview of papers on EME of polar substances. From this, different strategies to improve the mass transfer of polar substances are reviewed and critically discussed. These strategies include different SLM chemistries, modification of supporting membranes, sorbent additives, aqueous solution chemistry, and voltage/current related strategies. Finally, the future applicability of EME for polar substances is discussed. We expect EME in the coming years to be developed towards both very selective targeted analysis, as well as untargeted analysis of polar substances in biomedical applications such as metabolomics and peptidomics.
Collapse
Affiliation(s)
- Linda Vårdal Eie
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway
| | - Stig Pedersen-Bjergaard
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway; Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark
| | - Frederik André Hansen
- Department of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway.
| |
Collapse
|
10
|
Alidoust M, Baharfar M, Manouchehri M, Yamini Y, Tajik M, Seidi S. Emergence of microfluidic devices in sample extraction; an overview of diverse methodologies, principals, and recent advancements. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116352] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
11
|
Hansen FA, Petersen NJ, Kutter JP, Pedersen-Bjergaard S. Electromembrane extraction in microfluidic formats. J Sep Sci 2021; 45:246-257. [PMID: 34562339 DOI: 10.1002/jssc.202100603] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/29/2021] [Revised: 09/20/2021] [Accepted: 09/20/2021] [Indexed: 11/09/2022]
Abstract
Electromembrane extraction is a microextraction technique where charged analytes are extracted across a supported liquid membrane and selectively isolated from the sample based on an electrical field. Since the introduction in 2006, there has been continuously increasing interest in electromembrane extraction, and currently close to 50 new articles are published per year. Electromembrane extraction can be performed in different technical configurations, based on standard laboratory glass vials or 96-well plate systems, and applications are typically related to pharmaceutical, environmental, and food and beverages analysis. In addition to this, conceptual research has developed electromembrane extraction into different milli- and microfluidic formats. These are much more early-stage activities, but applications among others related to organ-on-chip systems and smartphone detection indicate unique perspectives. To stimulate more research in this direction, the current article reviews the scientific literature on electromembrane extraction in milli- and microfluidic formats. About 20 original research articles have been published on this subject so far, and these are discussed critically in the following. Based on this and the authors own experiences with the topic, we discuss perspectives, challenges, and future research.
Collapse
Affiliation(s)
| | - Nickolaj Jacob Petersen
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Jörg P Kutter
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| | - Stig Pedersen-Bjergaard
- Department of Pharmacy, University of Oslo, Oslo, Norway.,Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
12
|
Mahdavi P, Nojavan S, Asadi S. An investigation on the effect of filtration and dilution of biological samples on electromembrane extraction efficiency: Determination of basic drugs in plasma and urine samples. SEPARATION SCIENCE PLUS 2020. [DOI: 10.1002/sscp.202000058] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Parisa Mahdavi
- Department of analytical chemistry and pollutants Shahid Beheshti University Tehran Tehran Iran
| | - Saeed Nojavan
- Department of analytical chemistry and pollutants Shahid Beheshti University Tehran Tehran Iran
| | - Sakine Asadi
- Department of analytical chemistry and pollutants Shahid Beheshti University Tehran Tehran Iran
| |
Collapse
|
13
|
Impedance model for voltage optimization of parabens extraction in an electromembrane millifluidic device. J Chromatogr A 2020; 1625:461270. [DOI: 10.1016/j.chroma.2020.461270] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2020] [Revised: 05/10/2020] [Accepted: 05/21/2020] [Indexed: 12/16/2022]
|
14
|
Amoli HS, Yamini Y, Darmani H. Polyoxomolybdate 368 /polyaniline nanocomposite as a novel fiber for solid-phase microextraction of antidepressant drugs in biological samples. J Sep Sci 2020; 43:2636-2645. [PMID: 32277789 DOI: 10.1002/jssc.201901152] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2019] [Revised: 03/22/2020] [Accepted: 03/31/2020] [Indexed: 01/13/2023]
Abstract
A novel solid-phase microextraction fiber was synthesized by coating a stainless steel wire with polyoxomolybdate368 /polyaniline as a sorbent aimed at extraction of amitriptyline, nortriptyline, and doxepin as antidepressant drugs from urine and blood samples. The polyoxomolybdate368 /polyaniline composite coating was applied using electropolymerization process under constant potential. This composition leads to enhanced extraction efficiency of the fiber. Scanning electron microscopy images show that huge three-dimensional structures of polyoxomolybdate368 in composite induced more non-smooth and porous fiber. In order to optimize of the extraction process, a series of variables including concentration of the composite materials, coating thickness, pH, extraction time, salt addition, and stirring rate was investigated and optimum conditions were determined. Analysis of surface morphology and chemical composition was performed. High-performance liquid chromatography was used for separation and evaluation of mentioned antidepressant drugs from the matrixes. The experiments indicated a detection limits of <0.2 ng/L and a linear dynamic range of 0.3-100 ng/L (R2 > 0.994). The relative recovery values were found to be in the range of 92-98%. It was concluded that the purposed fiber is highly efficient in analyzing traces of antidepressant drugs in urine and blood.
Collapse
Affiliation(s)
| | - Yadollah Yamini
- Department of Chemistry, Tarbiat Modares University, Tehran, Iran
| | - Hossein Darmani
- Department of Chemistry, Amir Kabir University of Technology, Tehran, Iran
| |
Collapse
|
15
|
Karami M, Yamini Y. On-disc electromembrane extraction-dispersive liquid-liquid microextraction: A fast and effective method for extraction and determination of ionic target analytes from complex biofluids by GC/MS. Anal Chim Acta 2020; 1105:95-104. [DOI: 10.1016/j.aca.2020.01.024] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2019] [Revised: 01/10/2020] [Accepted: 01/12/2020] [Indexed: 01/05/2023]
|
16
|
Luiz Oenning A, Birk L, Eller S, Franco de Oliveira T, Merib J, Carasek E. A green and low-cost method employing switchable hydrophilicity solvent for the simultaneous determination of antidepressants in human urine by gas chromatography - mass spectrometry detection. J Chromatogr B Analyt Technol Biomed Life Sci 2020; 1143:122069. [PMID: 32213465 DOI: 10.1016/j.jchromb.2020.122069] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2020] [Revised: 03/10/2020] [Accepted: 03/12/2020] [Indexed: 01/23/2023]
Abstract
In this study, the use of switchable hydrophilicity solvent with a simple and low-cost lab-made device for the extraction procedure in homogeneous liquid-liquid microextraction is proposed for the first time in the determination of antidepressants in human urine. The antidepressants studied consisted of fluoxetine, amitriptyline, nortriptyline, imipramine, desipramine and sertraline. The optimization of the main parameters that can influence on the extraction efficiency was performed through multivariate approaches. The analytes were separated and identified by gas chromatography coupled to mass spectrometry (GC-MS). The optimal extraction conditions consisted of using N,N-dimethylcyclohexylamine (DMCHA) as the switchable hydrophilicity solvent (SHS), 500 µL of urine sample previously diluted with ultrapure water at 1:1 ratio (v/v), 200 μL of a mixture of SHS:HCl 6 mol L-1 (1:1 v/v), 600 μL of NaOH 10 mol L-1 and 3 min of extraction time. A volume of 40 µL of diphenylamine at concentration of 500 µg L-1 (20 ng) was used as internal standard. The method developed was in-house validated, providing coefficients of determination higher than 0.995 for all analytes, limits of detection (LOD) from 0.02 to 0.88 µg L-1, limits of quantification (LOQ) from 0.05 to 2.92 µg L-1, relative recoveries of 68 to 102%, intra-day precision from 0.5 to 15.9%, inter-day precision from 4.2 to 19.3%, selectivity and robustness. The method proposed was successfully applied in five human urine samples from a Toxicological Information Center located in Porto Alegre (Brazil). The results demonstrated that the µP-SHS-HLLME approach is highly cost-effective, rapid, simple and environmentally-friendly with satisfactory analytical performance.
Collapse
Affiliation(s)
- Anderson Luiz Oenning
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis 88040900, SC, Brazil
| | - Letícia Birk
- Departamento de Farmacociências, Universidade Federal de Ciências da Saúde de Porto Alegre, Porto Alegre 90050170, RS, Brazil
| | - Sarah Eller
- Departamento de Farmacociências, Universidade Federal de Ciências da Saúde de Porto Alegre, Porto Alegre 90050170, RS, Brazil
| | - Tiago Franco de Oliveira
- Departamento de Farmacociências, Universidade Federal de Ciências da Saúde de Porto Alegre, Porto Alegre 90050170, RS, Brazil
| | - Josias Merib
- Departamento de Farmacociências, Universidade Federal de Ciências da Saúde de Porto Alegre, Porto Alegre 90050170, RS, Brazil.
| | - Eduardo Carasek
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis 88040900, SC, Brazil.
| |
Collapse
|
17
|
Liquid - Phase microextraction and electromembrane extraction in millifluidic devices:A tutorial. Anal Chim Acta 2019; 1080:12-21. [DOI: 10.1016/j.aca.2019.05.075] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/05/2019] [Revised: 05/30/2019] [Accepted: 05/31/2019] [Indexed: 01/20/2023]
|
18
|
Ai Y, Zhang F, Wang C, Xie R, Liang Q. Recent progress in lab-on-a-chip for pharmaceutical analysis and pharmacological/toxicological test. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.06.026] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023]
|
19
|
Javier Carrasco-Correa E, Kubáň P, Cocovi-Solberg DJ, Miró M. Fully Automated Electric-Field-Driven Liquid Phase Microextraction System with Renewable Organic Membrane As a Front End to High Performance Liquid Chromatography. Anal Chem 2019; 91:10808-10815. [DOI: 10.1021/acs.analchem.9b02453] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
| | - Pavel Kubáň
- Institute of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, CZ-60200 Brno, Czech Republic
| | - David J. Cocovi-Solberg
- FI-TRACE group, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa, km 7.5, E-07122 Palma de Mallorca, Spain
| | - Manuel Miró
- FI-TRACE group, Department of Chemistry, University of the Balearic Islands, Carretera de Valldemossa, km 7.5, E-07122 Palma de Mallorca, Spain
| |
Collapse
|
20
|
Aranda-Merino N, Ramos-Payán M, Callejón-Mochón M, Villar-Navarro M, Fernández-Torres R. Effect of counter-ions on electromembrane extraction of non- steroidal antiinflammatory drugs. J Electroanal Chem (Lausanne) 2019. [DOI: 10.1016/j.jelechem.2019.03.075] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
21
|
Santigosa E, Maspoch S, Ramos Payán M. Liquid phase microextraction integrated into a microchip device for the extraction of fluoroquinolones from urine samples. Microchem J 2019. [DOI: 10.1016/j.microc.2018.10.051] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
22
|
Abstract
Saliva, as the first body fluid encountering with the exogenous materials, has good correlation with blood and plays an important role in bioanalysis. However, saliva has not been studied as much as the other biological fluids mainly due to restricted access to its large volumes. In recent years, there is a growing interest for saliva analysis owing to the emergence of miniaturized sample preparation methods. The purpose of this paper is to review all microextraction methods and their principles of operation. In the following, we examine the methods used to analyze saliva up to now and discuss the potential of the other microextraction methods for saliva analysis to encourage research groups for more focus on this important subject area.
Collapse
|
23
|
Zarghampour F, Yamini Y, Baharfar M, Faraji M. Simultaneous extraction of acidic and basic drugs via on-chip electromembrane extraction using a single-compartment microfluidic device. Analyst 2019; 144:1159-1166. [DOI: 10.1039/c8an01668b] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
A chip was designed for simultaneous extraction of acidic and basic drugs from biological fluids.
Collapse
Affiliation(s)
| | - Yadollah Yamini
- Department of Chemistry
- Faculty of Sciences
- Tarbiat Modares University
- Tehran
- Iran
| | - Mahroo Baharfar
- Department of Chemistry
- Faculty of Sciences
- Tarbiat Modares University
- Tehran
- Iran
| | - Mohammad Faraji
- Faculty of Food Industry and Agriculture
- Department of Food Science & Technology
- Standard Research Institute (SRI)
- Karaj
- Iran
| |
Collapse
|
24
|
Ramos Payán M, Santigosa E, Fernández Torres R, Bello López MÁ. A New Microchip Design. A Versatile Combination of Electromembrane Extraction and Liquid-Phase Microextraction in a Single Chip Device. Anal Chem 2018; 90:10417-10424. [DOI: 10.1021/acs.analchem.8b02292] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- María Ramos Payán
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, c/Prof. García González s/n, 41012 Seville, Spain
| | - Elia Santigosa
- Department of Analytical Chemistry, Universitat Autónoma de Barcelona, 08193 Bellaterra, Barcelona, Spain
| | - Rut Fernández Torres
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, c/Prof. García González s/n, 41012 Seville, Spain
| | - Miguel Ángel Bello López
- Department of Analytical Chemistry, Faculty of Chemistry, University of Seville, c/Prof. García González s/n, 41012 Seville, Spain
| |
Collapse
|
25
|
Hansen FA, Sticker D, Kutter JP, Petersen NJ, Pedersen-Bjergaard S. Nanoliter-Scale Electromembrane Extraction and Enrichment in a Microfluidic Chip. Anal Chem 2018; 90:9322-9329. [DOI: 10.1021/acs.analchem.8b01936] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Frederik A. Hansen
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark
| | - Drago Sticker
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark
| | - Jörg P. Kutter
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark
| | - Nickolaj J. Petersen
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark
| | - Stig Pedersen-Bjergaard
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen, Universitetsparken 2, 2100 Copenhagen, Denmark
- School of Pharmacy, University of Oslo, P.O. Box 1068 Blindern, 0316 Oslo, Norway
| |
Collapse
|
26
|
Safari M, Shahlaei M, Yamini Y, Shakorian M, Arkan E. Magnetic framework composite as sorbent for magnetic solid phase extraction coupled with high performance liquid chromatography for simultaneous extraction and determination of tricyclic antidepressants. Anal Chim Acta 2018; 1034:204-213. [PMID: 30193635 DOI: 10.1016/j.aca.2018.06.023] [Citation(s) in RCA: 65] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2018] [Revised: 06/03/2018] [Accepted: 06/08/2018] [Indexed: 01/15/2023]
Abstract
In this study, magnetic framework composites (MFCs) (Fe3O4@TMU-10) microspheres were successfully fabricated and applied as an effective sorbent for preconcentration of the two model tricyclic antidepressants (TCAs) amitriptyline and imipramine from biological samples. MFCs were fabricated by a step-by-step assembly, novel, simple and efficient strategy. The shell thickness of the Metal-organic frameworks (MOFs) could also be easily controlled by tuning the number of assembly cycles. By coupling magnetic solid-phase extraction (MSPE) with high-performance liquid chromatography with UV detector (HPLC-UV), a simple, reliable, fast, sensitive and cost-effective method for simultaneous determination of TCAs was developed. Under optimal conditions, the preconcentration factors and relative recoveries of the studied compounds were obtained in the range of 43-50 and 90.5-99.0% respectively. The calibration curves were obtained in the range of 5-800 μg L-1 with reasonable linearity (R2 > 0.9904) and the limits of detection (LODs) ranged between 2 and 4 μg L-1 (based on S/N = 3). The relative standard deviations of intra- and inter-day tests ranged from 3.1 to 4.6% and from 4.3 to 5.2%, respectively. The results demonstrate that Fe3O4@TMU-10 core-shell magnetic microspheres combine advantages of MOFs and magnetic nanoparticles, and are the promising sorbents for rapid and efficient extraction of target analytes from urine and plasma complex biological samples.
Collapse
Affiliation(s)
- Meysam Safari
- Pharmaceutical Sciences Research Center, Faculty of Pharmacy, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Mohsen Shahlaei
- Nano Drug Delivery Research Center, Kermanshah University of Medical Sciences, Iran.
| | - Yadollah Yamini
- Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
| | - Mehrzad Shakorian
- Department of Chemistry, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
| | - Elham Arkan
- Pharmaceutical Sciences Research Center, Faculty of Pharmacy, Kermanshah University of Medical Sciences, Kermanshah, Iran
| |
Collapse
|
27
|
A comprehensive study of a new versatile microchip device based liquid phase microextraction for stopped-flow and double-flow conditions. J Chromatogr A 2018; 1556:29-36. [DOI: 10.1016/j.chroma.2018.04.051] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 04/19/2018] [Accepted: 04/23/2018] [Indexed: 01/02/2023]
|
28
|
Electromembrane extraction of biogenic amines in food samples by a microfluidic-chip system followed by dabsyl derivatization prior to high performance liquid chromatography analysis. J Chromatogr A 2018; 1556:21-28. [DOI: 10.1016/j.chroma.2018.04.046] [Citation(s) in RCA: 34] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2018] [Revised: 04/18/2018] [Accepted: 04/22/2018] [Indexed: 11/17/2022]
|
29
|
Baharfar M, Yamini Y, Seidi S, Arain MB. Approach for Downscaling of Electromembrane Extraction as a Lab on-a-Chip Device Followed by Sensitive Red-Green-Blue Detection. Anal Chem 2018; 90:8478-8486. [DOI: 10.1021/acs.analchem.8b01224] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Affiliation(s)
- Mahroo Baharfar
- Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
| | - Yadollah Yamini
- Department of Chemistry, Faculty of Sciences, Tarbiat Modares University, P.O. Box 14115-175, Tehran, Iran
| | - Shahram Seidi
- Department of Analytical Chemistry, Faculty of Chemistry, K.N. Toosi University of Technology, 19697 Tehran, Iran
| | - Muhammad Balal Arain
- Department of Chemistry, Abdul Wali Khan University, Mardan, Khyber Pakhtunkhwa Pakistan, 23200
| |
Collapse
|
30
|
Recent advances in biological sample preparation methods coupled with chromatography, spectrometry and electrochemistry analysis techniques. Trends Analyt Chem 2018. [DOI: 10.1016/j.trac.2018.02.005] [Citation(s) in RCA: 94] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022]
|
31
|
Dvořák M, Seip KF, Pedersen-Bjergaard S, Kubáň P. Semi-automated set-up for exhaustive micro-electromembrane extractions of basic drugs from biological fluids. Anal Chim Acta 2018; 1005:34-42. [DOI: 10.1016/j.aca.2017.11.081] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2017] [Revised: 11/27/2017] [Accepted: 11/28/2017] [Indexed: 10/18/2022]
|
32
|
Sedehi S, Tabani H, Nojavan S. Electro-driven extraction of polar compounds using agarose gel as a new membrane: Determination of amino acids in fruit juice and human plasma samples. Talanta 2018; 179:318-325. [DOI: 10.1016/j.talanta.2017.11.009] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/21/2017] [Revised: 11/05/2017] [Accepted: 11/06/2017] [Indexed: 11/30/2022]
|
33
|
On-chip pulsed electromembrane extraction as a new concept for analysis of biological fluids in a small device. J Chromatogr A 2017; 1527:1-9. [DOI: 10.1016/j.chroma.2017.10.049] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2017] [Revised: 10/19/2017] [Accepted: 10/20/2017] [Indexed: 11/19/2022]
|
34
|
Baharfar M, Yamini Y, Seidi S, Karami M. Quantitative analysis of clonidine and ephedrine by a microfluidic system: On-chip electromembrane extraction followed by high performance liquid chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1068-1069:313-321. [DOI: 10.1016/j.jchromb.2017.10.062] [Citation(s) in RCA: 21] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2017] [Revised: 10/20/2017] [Accepted: 10/31/2017] [Indexed: 02/06/2023]
|
35
|
Vural Gürsel I, Kockmann N, Hessel V. Fluidic separation in microstructured devices – Concepts and their Integration into process flow networks. Chem Eng Sci 2017. [DOI: 10.1016/j.ces.2017.03.023] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023]
|
36
|
Fashi A, Khanban F, Yaftian MR, Zamani A. The cooperative effect of reduced graphene oxide and Triton X-114 on the electromembrane microextraction efficiency of Pramipexole as a model analyte in urine samples. Talanta 2017; 162:210-217. [DOI: 10.1016/j.talanta.2016.09.067] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/25/2016] [Revised: 09/26/2016] [Accepted: 09/28/2016] [Indexed: 11/29/2022]
|
37
|
Kokosa JM. Selecting an Appropriate Solvent Microextraction Mode for a Green Analytical Method. COMPREHENSIVE ANALYTICAL CHEMISTRY 2017. [DOI: 10.1016/bs.coac.2016.12.001] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
|
38
|
Huang L, Zhai H, Liang G, Su Z, Yuan K, Lu G, Pan Y. Chip-based dual-molecularly imprinted monolithic capillary array columns coated Ag/GO for selective extraction and simultaneous determination of bisphenol A and nonyl phenol in fish samples. J Chromatogr A 2016; 1474:14-22. [DOI: 10.1016/j.chroma.2016.10.074] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2016] [Revised: 10/26/2016] [Accepted: 10/28/2016] [Indexed: 01/06/2023]
|
39
|
Simultaneous extraction of acidic and basic drugs via on-chip electromembrane extraction. Anal Chim Acta 2016; 937:61-8. [DOI: 10.1016/j.aca.2016.07.048] [Citation(s) in RCA: 40] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2016] [Revised: 07/24/2016] [Accepted: 07/31/2016] [Indexed: 11/21/2022]
|
40
|
Oedit A, Ramautar R, Hankemeier T, Lindenburg PW. Electroextraction and electromembrane extraction: Advances in hyphenation to analytical techniques. Electrophoresis 2016; 37:1170-86. [PMID: 26864699 PMCID: PMC5071742 DOI: 10.1002/elps.201500530] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2015] [Revised: 01/06/2016] [Accepted: 01/31/2016] [Indexed: 12/16/2022]
Abstract
Electroextraction (EE) and electromembrane extraction (EME) are sample preparation techniques that both require an electric field that is applied over a liquid-liquid system, which enables the migration of charged analytes. Furthermore, both techniques are often used to pre-concentrate analytes prior to analysis. In this review an overview is provided of the body of literature spanning April 2012-November 2015 concerning EE and EME, focused on hyphenation to analytical techniques. First, the theoretical aspects of concentration enhancement in EE and EME are discussed to explain extraction recovery and enrichment factor. Next, overviews are provided of the techniques based on their hyphenation to LC, GC, CE, and direct detection. These overviews cover the compounds and matrices, experimental aspects (i.e. donor volume, acceptor volume, extraction time, extraction voltage, and separation time) and the analytical aspects (i.e. limit of detection, enrichment factor, and extraction recovery). Techniques that were either hyphenated online to analytical techniques or show high potential with respect to online hyphenation are highlighted. Finally, the potential future directions of EE and EME are discussed.
Collapse
Affiliation(s)
- Amar Oedit
- Division of Analytical Biosciences, Leiden Academic Center for Drug Research, Leiden University, Leiden, the Netherlands
| | - Rawi Ramautar
- Division of Analytical Biosciences, Leiden Academic Center for Drug Research, Leiden University, Leiden, the Netherlands
| | - Thomas Hankemeier
- Division of Analytical Biosciences, Leiden Academic Center for Drug Research, Leiden University, Leiden, the Netherlands
| | - Petrus W Lindenburg
- Division of Analytical Biosciences, Leiden Academic Center for Drug Research, Leiden University, Leiden, the Netherlands
| |
Collapse
|