1
|
Azuma N. Manipulation and analysis of large DNA molecules by controlling their dynamics using micro and nanogaps. Biosci Biotechnol Biochem 2025; 89:508-514. [PMID: 39611351 DOI: 10.1093/bbb/zbae179] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2024] [Accepted: 11/18/2024] [Indexed: 11/30/2024]
Abstract
Manipulation and analysis methods for large DNAs are critical for epidemiological, clinical, diagnostic, and fundamental research on bacteria, membrane vesicles, plants, yeast, and human cells. However, the physical properties of large DNAs often challenge their manipulation and analysis with high accuracy and speed using conventional methods such as gel electrophoresis and column-based methods. This review presents the approaches that leverage micrometer- and nanometer-sized gaps within microchannels to control the dynamics and conformations of large DNAs, thereby overcoming these challenges. By designing gap structures and migration conditions based on the relationship between gap parameters and the physical characteristics of large DNAs-such as diameter and persistence length-these methods enable swifter and more precise manipulation and analysis of large DNAs, including size separation, concentration, purification, and single-molecule analysis.
Collapse
Affiliation(s)
- Naoki Azuma
- Department of Micro-Nano Mechanical Science and Engineering, Nagoya University, Nagoya, Japan
| |
Collapse
|
2
|
Zeger VR, Thapa B, Shamsaei D, DeLair JF, Taylor TL, Anderson JL. Ionic Liquids in Analytical Chemistry: Fundamentals, Technological Advances, and Future Outlook. Anal Chem 2025; 97:4793-4818. [PMID: 40018979 PMCID: PMC11912132 DOI: 10.1021/acs.analchem.5c00264] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2025] [Revised: 02/04/2025] [Accepted: 02/12/2025] [Indexed: 03/01/2025]
|
3
|
Shanehband N, Naghib SM. Microfluidics-assisted Tumor Cell Separation Approaches for Clinical Applications: An Overview on Emerging Devices. Comb Chem High Throughput Screen 2025; 28:202-225. [PMID: 38275060 DOI: 10.2174/0113862073277130231110111933] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2023] [Revised: 09/25/2023] [Accepted: 09/27/2023] [Indexed: 01/27/2024]
Abstract
Recent advances in science and technology have led to revolutions in many scientific and industrial fields. The term lab on a chip, or in other words, performing a variety of complex analyses in just a short time and a minimal space, is a term that has become very common in recent years, and what used to be a dream has now come to life in practice. In this paper, we tried to investigate a specific type of lab technology on a chip, which is, of course, one of the most common, namely the knowledge and technology of cell separation by using a microfluidic technique that can be separated based on size and deformation, adhesion and electrical properties. The tissue of the human body is degraded due to injury or aging. It is often tried to treat this tissue disorder by using drugs, but they are not always enough. Stem cell-based medicine is a novel form that promises the restoration or regeneration of tissues and functioning organs. Although many models of microfluidic systems have been designed for cell separation, choosing the appropriate device to achieve a reliable result is a challenge. Therefore, in this study, Fluorescence Activated Cell Sorting (FACS), Dielectrophoresis (DEP), Magnetic Activated Cell Sorting (MACS), and Acoustic microfluidic system are four distinct categories of active microfluidic systems explored. Also, the advantages, disadvantages, and the current status of the devices mentioned in these methods are reviewed.
Collapse
Affiliation(s)
- Nahid Shanehband
- Nanotechnology Department, School of Advanced Technologies, Iran University of Science and Technology, Tehran, Iran
| | - Seyed Morteza Naghib
- Nanotechnology Department, School of Advanced Technologies, Iran University of Science and Technology, Tehran, Iran
| |
Collapse
|
4
|
Torres-Castro K, Acuña-Umaña K, Lesser-Rojas L, Reyes DR. Microfluidic Blood Separation: Key Technologies and Critical Figures of Merit. MICROMACHINES 2023; 14:2117. [PMID: 38004974 PMCID: PMC10672873 DOI: 10.3390/mi14112117] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 11/01/2023] [Accepted: 11/10/2023] [Indexed: 11/26/2023]
Abstract
Blood is a complex sample comprised mostly of plasma, red blood cells (RBCs), and other cells whose concentrations correlate to physiological or pathological health conditions. There are also many blood-circulating biomarkers, such as circulating tumor cells (CTCs) and various pathogens, that can be used as measurands to diagnose certain diseases. Microfluidic devices are attractive analytical tools for separating blood components in point-of-care (POC) applications. These platforms have the potential advantage of, among other features, being compact and portable. These features can eventually be exploited in clinics and rapid tests performed in households and low-income scenarios. Microfluidic systems have the added benefit of only needing small volumes of blood drawn from patients (from nanoliters to milliliters) while integrating (within the devices) the steps required before detecting analytes. Hence, these systems will reduce the associated costs of purifying blood components of interest (e.g., specific groups of cells or blood biomarkers) for studying and quantifying collected blood fractions. The microfluidic blood separation field has grown since the 2000s, and important advances have been reported in the last few years. Nonetheless, real POC microfluidic blood separation platforms are still elusive. A widespread consensus on what key figures of merit should be reported to assess the quality and yield of these platforms has not been achieved. Knowing what parameters should be reported for microfluidic blood separations will help achieve that consensus and establish a clear road map to promote further commercialization of these devices and attain real POC applications. This review provides an overview of the separation techniques currently used to separate blood components for higher throughput separations (number of cells or particles per minute). We present a summary of the critical parameters that should be considered when designing such devices and the figures of merit that should be explicitly reported when presenting a device's separation capabilities. Ultimately, reporting the relevant figures of merit will benefit this growing community and help pave the road toward commercialization of these microfluidic systems.
Collapse
Affiliation(s)
- Karina Torres-Castro
- Biophysical and Biomedical Measurements Group, National Institute of Standards and Technology (NIST), 100 Bureau Drive, Gaithersburg, MD 20899, USA;
- Theiss Research, La Jolla, CA 92037, USA
| | - Katherine Acuña-Umaña
- Medical Devices Master’s Program, Instituto Tecnológico de Costa Rica (ITCR), Cartago 30101, Costa Rica
| | - Leonardo Lesser-Rojas
- Research Center in Atomic, Nuclear and Molecular Sciences (CICANUM), San José 11501, Costa Rica;
- School of Physics, Universidad de Costa Rica (UCR), San José 11501, Costa Rica
| | - Darwin R. Reyes
- Biophysical and Biomedical Measurements Group, National Institute of Standards and Technology (NIST), 100 Bureau Drive, Gaithersburg, MD 20899, USA;
| |
Collapse
|
5
|
Ebrahimi A, Didarian R, Ghorbanpoor H, Dogan Guzel F, Hashempour H, Avci H. High-throughput microfluidic chip with silica gel-C18 channels for cyclotide separation. Anal Bioanal Chem 2023; 415:6873-6883. [PMID: 37792070 DOI: 10.1007/s00216-023-04966-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2023] [Revised: 09/13/2023] [Accepted: 09/18/2023] [Indexed: 10/05/2023]
Abstract
Over the past two decades, microfluidic-based separations have been used for the purification, isolation, and separation of biomolecules to overcome difficulties encountered by conventional chromatography-based methods including high cost, long processing times, sample volumes, and low separation efficiency. Cyclotides, or cyclic peptides used by some plant families as defense agents, have attracted the interest of scientists because of their biological activities varying from antimicrobial to anticancer properties. The separation process has a critical impact in terms of obtaining pure cyclotides for drug development strategies. Here, for the first time, a mimic of the high-performance liquid chromatography (HPLC) on microfluidic chip strategy was used to separate the cyclotides. In this regard, silica gel-C18 was synthesized and characterized by Fourier-transform infrared spectroscopy (FTIR) and proton nuclear magnetic resonance (1H-NMR) and then filled inside the microchannel to prepare an HPLC C18 column-like structure inside the microchannel. Cyclotide extract was obtained from Viola ignobilis by a low voltage electric field extraction method and characterized by HPLC and matrix-assisted laser desorption/ionization-time of flight (MALDI-TOF). The extract that contained vigno 1, 2, 3, 4, 5, and varv A cyclotides was added to the microchannel where distilled water was used as a mobile phase with 1 µL/min flow rate and then samples were collected in 2-min intervals until 10 min. Results show that cyclotides can be successfully separated from each other and collected from the microchannel at different periods of time. These findings demonstrate that the use of microfluidic channels has a high impact on the separation of cyclotides as a rapid, cost-effective, and simple method and the device can find widespread applications in drug discovery research.
Collapse
Affiliation(s)
- Aliakbar Ebrahimi
- Cellular Therapy and Stem Cell Production Application and Research Center (ESTEM), Eskişehir Osmangazi University, Eskişehir, Turkey
- Department of Biomedical Engineering, Ankara Yildirim Beyazit University, Ankara, Turkey
| | - Reza Didarian
- Department of Biomedical Engineering, Ankara Yildirim Beyazit University, Ankara, Turkey
- Department of Metallurgical and Materials Engineering, Eskişehir Osmangazi University, Eskişehir, Turkey
| | - Hamed Ghorbanpoor
- Cellular Therapy and Stem Cell Production Application and Research Center (ESTEM), Eskişehir Osmangazi University, Eskişehir, Turkey
- Department of Biomedical Engineering, Eskişehir Osmangazi University, Eskişehir, Turkey
| | - Fatma Dogan Guzel
- Department of Biomedical Engineering, Ankara Yildirim Beyazit University, Ankara, Turkey
| | - Hossein Hashempour
- Department of Chemistry, Faculty of Basic Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran
| | - Huseyin Avci
- Cellular Therapy and Stem Cell Production Application and Research Center (ESTEM), Eskişehir Osmangazi University, Eskişehir, Turkey.
- Department of Metallurgical and Materials Engineering, Eskişehir Osmangazi University, Eskişehir, Turkey.
- Translational Medicine Research and Clinical Center (TATUM), Eskişehir Osmangazi University, Eskişehir, Turkey.
| |
Collapse
|
6
|
Aparna GM, Tetala KKR. Recent Progress in Development and Application of DNA, Protein, Peptide, Glycan, Antibody, and Aptamer Microarrays. Biomolecules 2023; 13:602. [PMID: 37189350 PMCID: PMC10135839 DOI: 10.3390/biom13040602] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/23/2022] [Revised: 03/12/2023] [Accepted: 03/13/2023] [Indexed: 03/29/2023] Open
Abstract
Microarrays are one of the trailblazing technologies of the last two decades and have displayed their importance in all the associated fields of biology. They are widely explored to screen, identify, and gain insights on the characteristics traits of biomolecules (individually or in complex solutions). A wide variety of biomolecule-based microarrays (DNA microarrays, protein microarrays, glycan microarrays, antibody microarrays, peptide microarrays, and aptamer microarrays) are either commercially available or fabricated in-house by researchers to explore diverse substrates, surface coating, immobilization techniques, and detection strategies. The aim of this review is to explore the development of biomolecule-based microarray applications since 2018 onwards. Here, we have covered a different array of printing strategies, substrate surface modification, biomolecule immobilization strategies, detection techniques, and biomolecule-based microarray applications. The period of 2018-2022 focused on using biomolecule-based microarrays for the identification of biomarkers, detection of viruses, differentiation of multiple pathogens, etc. A few potential future applications of microarrays could be for personalized medicine, vaccine candidate screening, toxin screening, pathogen identification, and posttranslational modifications.
Collapse
Affiliation(s)
| | - Kishore K. R. Tetala
- Centre for Bioseparation Technology (CBST), Vellore Institute of Technology (VIT), Vellore 632014, Tamilnadu, India;
| |
Collapse
|
7
|
Pinheiro KMP, Duarte LM, Rodrigues MF, Vaz BG, Junior IM, Carvalho RM, Coltro WKT. Determination of naphthenic acids in produced water by using microchip electrophoresis with integrated contactless conductivity detection. J Chromatogr A 2022; 1677:463307. [PMID: 35834889 DOI: 10.1016/j.chroma.2022.463307] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2022] [Revised: 06/16/2022] [Accepted: 07/04/2022] [Indexed: 10/17/2022]
Abstract
This study reports for the first time the use of a microchip electrophoresis (ME) device with integrated capacitively coupled contactless conductivity detection (C4D) to analyze naphthenic acids in produced water. A mixture containing 9-anthracenecarboxylic, 1-naphthoic, and benzoic acids was separated and detected using a running buffer composed of 10 mmol L-1 carbonate buffer (pH = 10.2). The separation was achieved within ca. 140 s with baseline resolution greater than 2 and efficiency values ranging from 1.9 × 105 to 2.4 × 105 plates m-1. The developed methodology provided linear correlation with determination coefficients greater than 0.992 for the concentration ranges between 50 and 250 µmol L-1 for benzoic and 9-anthracenecarboxylic acids, and between 50 and 200 µmol L-1 for 1-naphthoic acid. The achieved limit of detection values varied between 4.7 and 7.7 µmol L-1. The proposed methodology revealed satisfactory repeatability with RSD values for a sequence of eight injections between 5.5 and 7.7% for peak areas and lower than 1% for migration times. In addition, inter-day precision was evaluated for sixteen injections (a sequence of four injections performed during four days), and the RSD values were lower than 11.5 and 4.9% for peak areas and migration time, respectively. Five produced water samples were analyzed, and it was possible to detect and quantify 9-anthracenecarboxylic acid. The concentrations ranged from 1.05 to 2.24 mmol L-1 with recovery values between 90.8 and 96.0%. ME-C4D demonstrated satisfactory analytical performance for determining naphthenic acids in produced water for the first time, which is useful for petroleum or oil industry investigation.
Collapse
Affiliation(s)
- Kemilly M P Pinheiro
- Instituto de Química, Universidade Federal de Goiás, Goiânia, GO 74690-900, Brazil
| | - Lucas M Duarte
- Instituto de Química, Universidade Federal de Goiás, Goiânia, GO 74690-900, Brazil; Instituto de Química, Universidade Federal Fluminense, Niterói, RJ 24020-141, Brazil
| | - Marcella F Rodrigues
- Instituto de Química, Universidade Federal de Goiás, Goiânia, GO 74690-900, Brazil
| | - Boniek G Vaz
- Instituto de Química, Universidade Federal de Goiás, Goiânia, GO 74690-900, Brazil
| | - Iris Medeiros Junior
- Centro de Pesquisas e Desenvolvimento Leopoldo Américo Miguez de Mello (CENPES), Rio de Janeiro, RJ 21040-000, Brazil
| | - Rogerio M Carvalho
- Centro de Pesquisas e Desenvolvimento Leopoldo Américo Miguez de Mello (CENPES), Rio de Janeiro, RJ 21040-000, Brazil
| | - Wendell K T Coltro
- Instituto de Química, Universidade Federal de Goiás, Goiânia, GO 74690-900, Brazil; Instituto Nacional de Ciência e Tecnologia de Bioanalítica, Campinas, SP 13084-971, Brazil.
| |
Collapse
|
8
|
Abrao-Nemeir I, Zaki O, Meyer N, Lepoitevin M, Torrent J, Janot JM, Balme S. Combining ionic diode, resistive pulse and membrane for detection and separation of anti-CD44 antibody. J Memb Sci 2022. [DOI: 10.1016/j.memsci.2022.120391] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
9
|
Hakim M, Kermanshah L, Abouali H, Hashemi HM, Yari A, Khorasheh F, Alemzadeh I, Vossoughi M. Unraveling Cancer Metastatic Cascade Using Microfluidics-based Technologies. Biophys Rev 2022; 14:517-543. [PMID: 35528034 PMCID: PMC9043145 DOI: 10.1007/s12551-022-00944-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2021] [Accepted: 03/14/2022] [Indexed: 12/24/2022] Open
Abstract
Cancer has long been a leading cause of death. The primary tumor, however, is not the main cause of death in more than 90% of cases. It is the complex process of metastasis that makes cancer deadly. The invasion metastasis cascade is the multi-step biological process of cancer cell dissemination to distant organ sites and adaptation to the new microenvironment site. Unraveling the metastasis process can provide great insight into cancer death prevention or even treatment. Microfluidics is a promising platform, that provides a wide range of applications in metastasis-related investigations. Cell culture microfluidic technologies for in vitro modeling of cancer tissues with fluid flow and the presence of mechanical factors have led to the organ-on-a-chip platforms. Moreover, microfluidic systems have also been exploited for capturing and characterization of circulating tumor cells (CTCs) that provide crucial information on the metastatic behavior of a tumor. We present a comprehensive review of the recent developments in the application of microfluidics-based systems for analysis and understanding of the metastasis cascade from a wider perspective.
Collapse
Affiliation(s)
- Maziar Hakim
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Leyla Kermanshah
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Hesam Abouali
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Hanieh Mohammad Hashemi
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Alireza Yari
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Farhad Khorasheh
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Iran Alemzadeh
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Manouchehr Vossoughi
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| |
Collapse
|
10
|
Tetala KKR. Preparation of Affinity Chromatography Monolith in Miniaturized Format and Application for Protein Separation. Methods Mol Biol 2022; 2466:229-240. [PMID: 35585321 DOI: 10.1007/978-1-0716-2176-9_15] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Affinity chromatography is one of the versatile technique to selectively separate target biomolecules from complex biological sources (plasma, saliva, urine, etc.). Conventional chromatography resins possess technical limitations at mini-analytical scale, which was overcome with the use of alternative material known as monoliths. This chapter discusses on the how to modify the fused silica capillary inner surface, prepare polymer monoliths within the capillary confinements, chelation of metal-ions on monoliths and protein separation from diluted human plasma using metal-ion monolith microcolumn.
Collapse
Affiliation(s)
- Kishore K R Tetala
- Centre for Bioseparation Technology (CBST), Vellore Institute of Technology (VIT), Vellore, Tamil Nadu, India.
| |
Collapse
|
11
|
Hakim M, Khorasheh F, Alemzadeh I, Vossoughi M. A new insight to deformability correlation of circulating tumor cells with metastatic behavior by application of a new deformability-based microfluidic chip. Anal Chim Acta 2021; 1186:339115. [PMID: 34756251 DOI: 10.1016/j.aca.2021.339115] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Revised: 09/22/2021] [Accepted: 09/23/2021] [Indexed: 11/18/2022]
Abstract
Isolation and characterization of circulating tumor cells (CTCs) found in blood samples of cancer patients have been considered as a reliable source for cancer prognosis and diagnosis. A new continuous microfluidic platform has been designed in this investigation for simultaneous capture and characterization of CTCs based on their deformability. The deformability-based chip (D-Chip) consists of two sections of separation and characterization where slanted weirs with a gap of 7 μm were considered. Although sometimes CTCs and leukocytes have the same size, the deformability differs in such a way that can be exploited for enrichment purposes. MCF7 and MDA-MB-231 cell lines were used for the initial evaluation of the D-Chip performance. In the separation section, cancer cells were isolated based on deformability differences with an efficiency of higher than 93% (∼average capturing capacity of 2085 out of 2200 cancer cells ml-1) and with significantly high purity (15-40 WBCs ml-1; ∼5 log depletion of WBCs). Cancer cells were categorized based on the deformability difference in the characterization section. Subsequently, 15 clinical blood samples from breast cancer patients were analyzed by the D-Chip. Suggest 'The chip detected CTCs in all patient samples, processed the blood sample at a high throughput of 5.3 ml/h, and properly categorized CTCs based on deformability differences. Further characterization showed that the highly deformable breast cancer CTCs in our patient samples also showed higher potential of metastasis in support of a broader correlation between deformability of CTCs and metastatic behavior.
Collapse
Affiliation(s)
- Maziar Hakim
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Farhad Khorasheh
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Iran Alemzadeh
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran
| | - Manouchehr Vossoughi
- Department of Chemical and Petroleum Engineering, Sharif University of Technology, Tehran, Iran.
| |
Collapse
|
12
|
Choe SW, Kim B, Kim M. Progress of Microfluidic Continuous Separation Techniques for Micro-/Nanoscale Bioparticles. BIOSENSORS 2021; 11:464. [PMID: 34821680 PMCID: PMC8615634 DOI: 10.3390/bios11110464] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2021] [Revised: 11/07/2021] [Accepted: 11/12/2021] [Indexed: 05/03/2023]
Abstract
Separation of micro- and nano-sized biological particles, such as cells, proteins, and nucleotides, is at the heart of most biochemical sensing/analysis, including in vitro biosensing, diagnostics, drug development, proteomics, and genomics. However, most of the conventional particle separation techniques are based on membrane filtration techniques, whose efficiency is limited by membrane characteristics, such as pore size, porosity, surface charge density, or biocompatibility, which results in a reduction in the separation efficiency of bioparticles of various sizes and types. In addition, since other conventional separation methods, such as centrifugation, chromatography, and precipitation, are difficult to perform in a continuous manner, requiring multiple preparation steps with a relatively large minimum sample volume is necessary for stable bioprocessing. Recently, microfluidic engineering enables more efficient separation in a continuous flow with rapid processing of small volumes of rare biological samples, such as DNA, proteins, viruses, exosomes, and even cells. In this paper, we present a comprehensive review of the recent advances in microfluidic separation of micro-/nano-sized bioparticles by summarizing the physical principles behind the separation system and practical examples of biomedical applications.
Collapse
Affiliation(s)
- Se-woon Choe
- Department of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea;
- Department of IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea
| | - Bumjoo Kim
- Department of Mechanical Engineering and Automotive Engineering, Kongju National University, Cheonan 1223-24, Korea;
- Department of Future Convergence Engineering, Kongju National University, Cheonan 1223-24, Korea
| | - Minseok Kim
- Department of Mechanical System Engineering, Kumoh National Institute of Technology, Gumi 39177, Korea
- Department of Aeronautics, Mechanical and Electronic Convergence Engineering, Kumoh National Institute of Technology, Gumi 39177, Korea
| |
Collapse
|
13
|
Kumari M, Tetala KKR. A review on recent advances in the enrichment of glycopeptides and glycoproteins by liquid chromatographic methods: 2016-Present. Electrophoresis 2021; 43:388-402. [PMID: 34757643 DOI: 10.1002/elps.202100172] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Revised: 11/05/2021] [Accepted: 11/06/2021] [Indexed: 01/06/2023]
Abstract
Among various protein post-translational modifications (PTMs), glycosylation has received special attention due to its immense role in molecular interactions, cellular signal transduction, immune response, etc. Aberration in glycan moieties of a glycoprotein is associated with cancer, diabetes, and bacterial and viral infections. In biofluids (plasma, saliva, urine, milk, etc.), glycoproteins are low in abundance and are masked by the presence of high abundant proteins. Hence, prior to their identification using mass spectrometry methods, liquid chromatography (LC)-based approaches were widely used. A general enrichment strategy involves a protein digestion step, followed by LC-based enrichment and desorption of glycopeptides, and enzymatic excision of the glycans. The focus of this review article is to highlight the articles published since 2016 that dealt with different LC-based approaches for glycopeptide and glycoprotein enrichment. The preparation of stationary phases, their surface activation, and ligand immobilization strategies have been discussed in detail. Finally, the major developments and future trends in the field have been summarized.
Collapse
Affiliation(s)
- Mona Kumari
- Centre for Bioseparation Technology (CBST), Vellore Institute of Technology (VIT), Vellore, Tamilnadu, India
| | - Kishore K R Tetala
- Centre for Bioseparation Technology (CBST), Vellore Institute of Technology (VIT), Vellore, Tamilnadu, India
| |
Collapse
|
14
|
Khaparde A, Lokesh Kumar S, Vijayalakshmi MA, Tetala KKR. A conjoint multi metal-ion iminodiacetic acid monolith microfluidic chip for structural-based protein pre-fractionation. Electrophoresis 2021; 42:2647-2655. [PMID: 34687221 DOI: 10.1002/elps.202100288] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2021] [Revised: 09/12/2021] [Accepted: 10/18/2021] [Indexed: 11/06/2022]
Abstract
PDMS-based multichannel microfluidic chip was designed and fabricated in a simple approach using readily available tools. UV-initiated in situ polymerization of poly(2-hydroxy ethyl methacrylate-co-di(ethylene glycol) diacrylate-co-N,N'-diallyl l-tartardiamide) in an Eppendorf tube was achieved within 40 min. This polymerization process was successfully translated to a microfluidic chip format without any further modifications. Iminodiacetic acid was successfully immobilized on aldehyde functional monoliths via Schiff base reaction and confirmed by FT-IR spectroscopy. Four transition metal ions (Co (II), Zn (II), Ni (II), and Cu (II)) were chelated individually on four IDA-monolith microfluidic chips. The conjoint metal-ion monolith microfluidic chip has displayed high permeability (9.40 × 10-13 m2 ) and a porosity of 32.8%. This affinity microfluidic chip has pre-fractioned four human plasma proteins (fibrinogen, immunoglobulin, transferrin, and human serum albumin) based on their surface-exposed histidine surface topography. A protein recovery of approximately 95% (Bradford assay data) was achieved. The multimonolith microchip can be reusable even after three protein adsorption-desorption cycles.
Collapse
Affiliation(s)
- Ashish Khaparde
- Centre for Bioseparation Technology (CBST), Vellore Institute of Technology (VIT), Vellore, Tamil Nadu, 632014, India
| | - S Lokesh Kumar
- Centre for Bioseparation Technology (CBST), Vellore Institute of Technology (VIT), Vellore, Tamil Nadu, 632014, India
| | - M A Vijayalakshmi
- Centre for Bioseparation Technology (CBST), Vellore Institute of Technology (VIT), Vellore, Tamil Nadu, 632014, India
| | - Kishore K R Tetala
- Centre for Bioseparation Technology (CBST), Vellore Institute of Technology (VIT), Vellore, Tamil Nadu, 632014, India
| |
Collapse
|
15
|
Alidoust M, Baharfar M, Manouchehri M, Yamini Y, Tajik M, Seidi S. Emergence of microfluidic devices in sample extraction; an overview of diverse methodologies, principals, and recent advancements. Trends Analyt Chem 2021. [DOI: 10.1016/j.trac.2021.116352] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
|
16
|
Rahman M, Sampad MJN, Hawkins A, Schmidt H. Recent advances in integrated solid-state nanopore sensors. LAB ON A CHIP 2021; 21:3030-3052. [PMID: 34137407 PMCID: PMC8372664 DOI: 10.1039/d1lc00294e] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/10/2023]
Abstract
The advent of single-molecule probing techniques has revolutionized the biomedical and life science fields and has spurred the development of a new class of labs-on-chip based on powerful biosensors. Nanopores represent one of the most recent and most promising single molecule sensing paradigms that is seeing increased chip-scale integration for improved convenience and performance. Due to their physical structure, nanopores are highly sensitive, require low sample volume, and offer label-free, amplification-free, high-throughput real-time detection and identification of biomolecules. Over the last 25 years, nanopores have been extensively employed to detect a variety of biomolecules with a growing range of applicatons ranging from nucleic acid sequencing to ultrasensitive diagnostics to single-molecule biophysics. Nanopores, in particular those in solid-state membranes, also have the potential for integration with other technologies such as optics, plasmonics, microfluidics, and optofluidics to perform more complex tasks for an ever-expanding demand. A number of breakthrough results using integrated nanopore platforms have already been reported, and more can be expected as nanopores remain the focus of innovative research and are finding their way into commercial instruments. This review provides an overview of different aspects and challenges of nanopore technology with a focus on chip-scale integration of solid-state nanopores for biosensing and bioanalytical applications.
Collapse
Affiliation(s)
- Mahmudur Rahman
- School of Engineering, University of California Santa Cruz, 1156 High Street, Santa Cruz, CA, 95064 USA. and Dhaka University of Engineering & Technology, Gazipur, Bangladesh
| | | | - Aaron Hawkins
- ECEn Department, Brigham Young University, 459 Clyde Building, Provo, UT, 84602 USA
| | - Holger Schmidt
- School of Engineering, University of California Santa Cruz, 1156 High Street, Santa Cruz, CA, 95064 USA.
| |
Collapse
|
17
|
Azevedo NF, Allkja J, Goeres DM. Biofilms vs. cities and humans vs. aliens - a tale of reproducibility in biofilms. Trends Microbiol 2021; 29:1062-1071. [PMID: 34088548 DOI: 10.1016/j.tim.2021.05.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Revised: 05/05/2021] [Accepted: 05/06/2021] [Indexed: 12/14/2022]
Abstract
Biofilms are complex and dynamic structures that include many more components than just viable cells. Therefore, the apparently simple goal of growing reproducible biofilms is often elusive. One of the challenges in defining reproducibility for biofilm research is that different research fields use a spectrum of parameters to define reproducibility for their particular application. For instance, is the researcher interested in achieving a similar population density, height of biofilm structures, or function of the biofilm in a certain ecosystem/industrial context? Within this article we categorize reproducibility into four different levels: level 1, no reproducibility; level 2, standard reproducibility; level 3, potential standard reproducibility; and level 4, total reproducibility. To better understand the need for these different levels of reproducibility, we expand on the 'cities of microbes' analogy for biofilms by imagining that a new civilization has reached the Earth's outskirts and starts studying the Earth's cities. This will provide a better sense of scale and illustrate how small details can impact profoundly on the growth and behavior of a biofilm and our understanding of reproducibility.
Collapse
Affiliation(s)
- Nuno F Azevedo
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology, and Energy, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal.
| | - Jontana Allkja
- LEPABE - Laboratory for Process Engineering, Environment, Biotechnology, and Energy, Faculty of Engineering, University of Porto, Rua Dr Roberto Frias, 4200-465 Porto, Portugal
| | - Darla M Goeres
- Montana State University, Center for Biofilm Engineering, 366 Barnard Hall, Bozeman, MT 59717, USA
| |
Collapse
|
18
|
Integration of microfluidic sample preparation with PCR detection to investigate the effects of simultaneous DNA-Inhibitor separation and DNA solution exchange. Anal Chim Acta 2021; 1160:338449. [PMID: 33894958 DOI: 10.1016/j.aca.2021.338449] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/13/2020] [Revised: 02/23/2021] [Accepted: 03/21/2021] [Indexed: 11/20/2022]
Abstract
In this paper, we applied a curved-channel microfluidic device to separate DNA from PCR-inhibitor-containing water and simultaneously wash them into clean water for detection using a portable PCR thermocycler. Environmental DNA (eDNA) sampling has become an effective surveying approach for detecting rare organisms. However, low concentration eDNA molecules may be masked by PCR inhibitors during amplification and detection, increasing the risk of false negatives. Therefore, technologies for on-site DNA separation and washing are urgently needed. Our device consisted of a half-circle microchannel with a DNA-inhibitor sample inlet, a clean buffer inlet, and multiple outlets. By using the flow-induced inertial forces, 10 μm DNA-conjugated microparticles were focused at the inner-wall of the curved microchannel while separation from 1 μm inhibitor-conjugated microparticles and DNA washing were achieved simultaneously with the Dean flow. We achieved singleplex focusing, isolation and washing of 10 μm particles at an efficiency of 94.5 ± 2.0%. In duplex experiments with 1 μm and 10 μm particles, larger particles were washed with an efficiency of 92.1 ± 1.6% and a purity of 79 ± 2%. By surface-functionalizing the microparticles with affinity groups against Atlantic salmon DNA and humic acid (HA), and processing samples of various concentrations in our device, we achieved an effective purification and detection of DNA molecules using the portable PCR thermocycler. Our method significantly decreased PCR quantitation cycles from Cq > 38 to Cq = 30.35 ± 0.5, which confirmed enhancement of PCR amplification. The proposed device takes a promising step forward in sample preparation towards an integrated device that can be used for simultaneous purification and solution exchange of DNA in point-of-need environmental monitoring applications.
Collapse
|
19
|
Zandieh M, Liu J. Spherical Nucleic Acid Mediated Functionalization of Polydopamine-Coated Nanoparticles for Selective DNA Extraction and Detection. Bioconjug Chem 2021; 32:801-809. [PMID: 33711232 DOI: 10.1021/acs.bioconjchem.1c00078] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
Abstract
Magnetic nanoparticles have been widely used for the separation of biomolecules for biological applications due to the mild and efficient separation process. In previous studies, core-shell magnetic nanoparticles (NPs) were designed for DNA extraction without much sequence specificity. In this work, to achieve highly selective DNA extraction, we designed a core-shell magnetic structure by coating polydopamine (PDA) on Fe3O4 NPs. Without divalent metal ions, PDA does not adsorb DNA at neutral pH. The Fe3O4@PDA NPs were then functionalized with spherical nucleic acids (SNA) to provide a high density of probe DNA. Fe3O4@PDA@SNA was also compared with when a linear SH-DNA was covalently attached to the NPs surface, showing a higher density of the probe SNA than SH-DNA can be loaded on the NPs in a remarkably shorter time. Nonspecific DNA extraction was thoroughly inhibited by both probes. DNA extraction by the Fe3O4@PDA@SNA was more effective as well as 5-fold faster than by the Fe3O4@PDA@SH-DNA, probably due to the favorable standing conformation of DNA strands in SNA. Moreover, extraction by Fe3O4@PDA@SNA showed high robustness in fetal bovine serum, and the same design can be used for selective detection of DNA. Finally, the method was also demonstrated on silica NPs and WS2 nanosheets for coating with PDA and SNA. Altogether, our findings revealed an interesting and general surface modification strategy using PDA@SNA conjugates for sequence-specific DNA extraction.
Collapse
Affiliation(s)
- Mohamad Zandieh
- Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada
| | - Juewen Liu
- Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo, Waterloo, Ontario N2L 3G1, Canada.,Centre for Eye and Vision Research, 17W Hong Kong Science Park, Hong Kong, SAR China
| |
Collapse
|
20
|
Abstract
Nanoparticles and biological molecules high throughput robust separation is of significant interest in many healthcare and nanoscience industrial applications. In this work, we report an on-chip automatic efficient separation and preconcentration method of dissimilar sized particles within a microfluidic platform using integrated membrane valves controlled microfiltration. Micro-sized E. coli bacteria are sorted from nanoparticles and preconcentrated on a microfluidic chip with six integrated pneumatic valves (sub-100 nL dead volume) using hydrophilic PVDF filter with 0.45 μm pore diameter. The proposed on-chip automatic sorting sequence includes a sample filtration, dead volume washout and retentate backflush in reverse flow. We showed that pulse backflush mode and volume control can dramatically increase microparticles sorting and preconcentration efficiency. We demonstrate that at the optimal pulse backflush regime a separation efficiency of E. coli cells up to 81.33% at a separation throughput of 120.45 μL/min can be achieved. A trimmed mode when the backflush volume is twice smaller than the initial sample results in a preconcentration efficiency of E. coli cells up to 121.96% at a throughput of 80.93 μL/min. Finally, we propose a cyclic on-chip preconcentration method which demonstrates E. coli cells preconcentration efficiency of 536% at a throughput of 1.98 μL/min and 294% preconcentration efficiency at a 10.9 μL/min throughput.
Collapse
|
21
|
A micro-solid phase extraction device to prepare a molecularly imprinted porous monolith in a facile mode for fast protein separation. J Chromatogr A 2020; 1627:461415. [DOI: 10.1016/j.chroma.2020.461415] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2020] [Revised: 07/13/2020] [Accepted: 07/15/2020] [Indexed: 01/08/2023]
|
22
|
Ragab MAA, El-Kimary EI. Recent Advances and Applications of Microfluidic Capillary Electrophoresis: A Comprehensive Review (2017-Mid 2019). Crit Rev Anal Chem 2020; 51:709-741. [PMID: 32447968 DOI: 10.1080/10408347.2020.1765729] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Microfluidic capillary electrophoresis (MCE) is the novel technique resulted from the CE mininaturization as planar separation and analysis device. This review presents and discusses various application fields of this advanced technology published in the period 2017 till mid-2019 in eight different sections including clinical, biological, single cell analysis, environmental, pharmaceuticals, food analysis, forensic and ion analysis. The need for miniaturization of CE and the consequence advantages achieved are also discussed including high-throughput, miniaturized detection, effective separation, portability and the need for micro- or even nano-volume of samples. Comprehensive tables for the MCE applications in the different studied fields are provided. Also, figure comparing the number of the published papers applying MCE in the eight discussed fields within the studied period is included. The future investigation should put into consideration the possibility of replacing conventional CE with the MCE after proper validation. Suitable validation parameters with their suitable accepted ranges should be tailored for analysis methods utilizing such unique technique (MCE).
Collapse
Affiliation(s)
- Marwa A A Ragab
- Faculty of Pharmacy, Department of Pharmaceutical Analytical Chemistry, Alexandria University, El-Messalah, Alexandria, Egypt
| | - Eman I El-Kimary
- Faculty of Pharmacy, Department of Pharmaceutical Analytical Chemistry, Alexandria University, El-Messalah, Alexandria, Egypt
| |
Collapse
|
23
|
Deraney RN, Schneider L, Tripathi A. Synergistic use of electroosmotic flow and magnetic forces for nucleic acid extraction. Analyst 2020; 145:2412-2419. [PMID: 32057055 DOI: 10.1039/c9an02191d] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/20/2023]
Abstract
Nucleic acid sample preparation is essential for biological sample-based diagnostics. It is crucial that diagnostic tests be both specific and sensitive as to provide the most accurate diagnosis possible. Inefficient sample preparation can hinder the specificity and sensitivity of these tests since carryover contaminants can inhibit downstream processes, such as amplification. Microfluidic devices have been used previously to extract nucleic acids from a biological sample due to lower reagent volumes and ease of use. A novel microfluidic chip has been designed for nucleic acid sample preparation which combines electroosmotic flow and magnetic bead-based extraction to isolate DNA from a plasma sample. A steady electric field was incorporated into the microfluidic chip design, which when combined with a glass clover slip and a voltage differential, creates electroosmotic flow. With the goal of isolating nucleic acids into a clean, inhibitor free solution, the electroosmotic flow is the driving force and separation mechanism purifying the DNA sample captured on magnetic beads in the microfluidic chip system. Carryover volume, or the volume of unwanted sample contaminants that accompany the nucleic acids into the final elution buffer, was minimized to 0.22 ± 0.03%. In combination with magnetic bead based nucleic acid extraction techniques, a 15% increase in DNA extraction yield is reported for the microfluidic chip with the voltage applied versus without. Although the literature on nucleic acid separation in microfluidic chips is abundant, this is the first to combine microfluidic chip design, magnetic bead-based isolation and electroosmotic flow.
Collapse
Affiliation(s)
- Rachel N Deraney
- Center for Biomedical Engineering, School of Engineering, Brown University, 182 Hope Street, Providence, RI 02912, USA.
| | | | | |
Collapse
|
24
|
Zhu L, Xu N, Zhang ZL, Zhang TC. Cell derived extracellular vesicles: from isolation to functionalization and biomedical applications. Biomater Sci 2020; 7:3552-3565. [PMID: 31313767 DOI: 10.1039/c9bm00580c] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Extracellular vesicles (EVs) are shed from most mammalian cells by different processes. EVs possess several distinct advantages, including excellent biocompatibility, good bio-stability and low immunogenicity. Moreover, they play significant roles in physiological and pathological processes. Challenges in EV research mainly concern highly efficient isolation, specific membrane surface engineering and further development of EV applications in biomedical fields. In this review, we summarize the recent and representative research regarding isolation, engineering and biomedical applications of EVs, which represent important research focus areas. These three aspects have not ever been systematically classified and summarized in previous reviews. Finally, we give our insights into the key issues concerning EVs and their future development for biomedical applications.
Collapse
Affiliation(s)
- Lian Zhu
- College of Life Sciences and Health, Wuhan University of Science and Technology, Wuhan, Hubei Province, China.
| | | | | | | |
Collapse
|
25
|
Fabrication, Characterization and Application of Biomolecule Micropatterns on Cyclic Olefin Polymer (COP) Surfaces with Adjustable Contrast. BIOSENSORS-BASEL 2019; 10:bios10010003. [PMID: 31905666 PMCID: PMC7168193 DOI: 10.3390/bios10010003] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/17/2019] [Revised: 12/19/2019] [Accepted: 12/25/2019] [Indexed: 01/08/2023]
Abstract
Peptide and protein micropatterns are powerful tools for the investigation of various cellular processes, including protein–protein interactions (PPIs). Within recent years, various approaches for the production of functional surfaces have been developed. Most of these systems use glass as a substrate, which has several drawbacks, including high fragility and costs, especially if implemented for fluorescence microscopy. In addition, conventional fabrication technologies such as microcontact printing (µCP) are frequently used for the transfer of biomolecules to the glass surface. In this case, it is challenging to adjust the biomolecule density. Here, we show that cyclic olefin polymer (COP) foils, with their encouraging properties, including the ease of manufacturing, chemical resistance, biocompatibility, low water absorption, and optical clarity, are a promising alternative to glass substrates for the fabrication of micropatterns. Using a photolithography-based approach, we generated streptavidin/biotinylated antibody patterns on COPs with the possibility of adjusting the pattern contrast by varying plasma activation parameters. Our experimental setup was finally successfully implemented for the analysis of PPIs in the membranes of live cells via total internal reflection fluorescence (TIRF) microscopy.
Collapse
|
26
|
Ma S, Li Y, Ma C, Wang Y, Ou J, Ye M. Challenges and Advances in the Fabrication of Monolithic Bioseparation Materials and their Applications in Proteomics Research. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2019; 31:e1902023. [PMID: 31502719 DOI: 10.1002/adma.201902023] [Citation(s) in RCA: 33] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/30/2019] [Revised: 06/29/2019] [Indexed: 06/10/2023]
Abstract
High-performance liquid chromatography integrated with tandem mass spectrometry (HPLC-MS/MS) has become a powerful technique for proteomics research. Its performance heavily depends on the separation efficiency of HPLC, which in turn depends on the chromatographic material. As the "heart" of the HPLC system, the chromatographic material is required to achieve excellent column efficiency and fast analysis. Monolithic materials, fabricated as continuous supports with interconnected skeletal structure and flow-through pores, are regarded as an alternative to particle-packed columns. Such materials are featured with easy preparation, fast mass transfer, high porosity, low back pressure, and miniaturization, and are next-generation separation materials for high-throughput proteins and peptides analysis. Herein, the recent progress regarding the fabrication of various monolithic materials is reviewed. Special emphasis is placed on studies of the fabrication of monolithic capillary columns and their applications in separation of biomolecules by capillary liquid chromatography (cLC). The applications of monolithic materials in the digestion, enrichment, and separation of phosphopeptides and glycopeptides from biological samples are also considered. Finally, advances in comprehensive 2D HPLC separations using monolithic columns are also shown.
Collapse
Affiliation(s)
- Shujuan Ma
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Dalian, 116023, China
| | - Ya Li
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Dalian, 116023, China
| | - Chen Ma
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Dalian, 116023, China
| | - Yan Wang
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Dalian, 116023, China
| | - Junjie Ou
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Dalian, 116023, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Mingliang Ye
- CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Dalian, 116023, China
- University of Chinese Academy of Sciences, Beijing, 100049, China
| |
Collapse
|
27
|
Pang L, Quan H, Sun Y, Wang P, Ma D, Mu P, Chai T, Zhang Y, Hammock BD. A rapid competitive ELISA assay of Okadaic acid level based on epoxy-functionalized magnetic beads. FOOD AGR IMMUNOL 2019. [DOI: 10.1080/09540105.2019.1689231] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022] Open
Affiliation(s)
- Linjiang Pang
- School of Agriculture and Food Science, Zhejiang A&F University, Hangzhou, People’s Republic of China
| | - Haoran Quan
- School of Agriculture and Food Science, Zhejiang A&F University, Hangzhou, People’s Republic of China
| | - Ying Sun
- Institute of Food and Drug Inspection and Testing Research of Zhoushan, Zhoushan, People’s Republic of China
| | - Pingya Wang
- Institute of Food and Drug Inspection and Testing Research of Zhoushan, Zhoushan, People’s Republic of China
| | - Daifu Ma
- Xuzhou Institute of Agricultural Sciences of the Xuhuai District of Jiangsu Province, Xuzhou, People’s Republic of China
| | - Pengqian Mu
- China Asia Pacific Application Support Center, AB SCIEX, Shanghai, People’s Republic of China
| | - Tingting Chai
- School of Agriculture and Food Science, Zhejiang A&F University, Hangzhou, People’s Republic of China
| | - Yiming Zhang
- School of Agriculture and Food Science, Zhejiang A&F University, Hangzhou, People’s Republic of China
| | - Bruce D. Hammock
- Department of Entomology and UCD Comprehensive Cancer Center, University of California, Davis, CA, USA
| |
Collapse
|
28
|
Assessment of immunoglobulin capture in immobilized protein A through automatic bead injection. Talanta 2019; 204:542-547. [DOI: 10.1016/j.talanta.2019.06.023] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 06/06/2019] [Accepted: 06/07/2019] [Indexed: 12/11/2022]
|
29
|
Current trends in affinity-based monoliths in microextraction approaches: A review. Anal Chim Acta 2019; 1084:1-20. [DOI: 10.1016/j.aca.2019.07.020] [Citation(s) in RCA: 28] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/13/2019] [Revised: 07/08/2019] [Accepted: 07/09/2019] [Indexed: 12/15/2022]
|
30
|
Davies CD, Johnson SE, Crooks RM. Effect of Chloride Oxidation on Local Electric Fields in Microelectrochemical Systems. ChemElectroChem 2019. [DOI: 10.1002/celc.201901402] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Affiliation(s)
- Collin D. Davies
- Department of Chemistry and Texas Materials Institute The University of Texas at Austin 105 E. 24th St., Stop A5300 Austin, Texas 78712-1224 U.S.A
| | - Sarah E. Johnson
- Department of Chemistry and Texas Materials Institute The University of Texas at Austin 105 E. 24th St., Stop A5300 Austin, Texas 78712-1224 U.S.A
| | - Richard M. Crooks
- Department of Chemistry and Texas Materials Institute The University of Texas at Austin 105 E. 24th St., Stop A5300 Austin, Texas 78712-1224 U.S.A
| |
Collapse
|
31
|
Piendl SK, Raddatz CR, Hartner NT, Thoben C, Warias R, Zimmermann S, Belder D. 2D in Seconds: Coupling of Chip-HPLC with Ion Mobility Spectrometry. Anal Chem 2019; 91:7613-7620. [DOI: 10.1021/acs.analchem.9b00302] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Sebastian K. Piendl
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Christian-Robert Raddatz
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Nora T. Hartner
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Christian Thoben
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Rico Warias
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| | - Stefan Zimmermann
- Leibniz University Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstrasse 9A, 30167 Hannover, Germany
| | - Detlev Belder
- Institute of Analytical Chemistry, Leipzig University, Linnéstraße 3, 04103 Leipzig, Germany
| |
Collapse
|
32
|
Parker EK, Nielsen AV, Beauchamp MJ, Almughamsi HM, Nielsen JB, Sonker M, Gong H, Nordin GP, Woolley AT. 3D printed microfluidic devices with immunoaffinity monoliths for extraction of preterm birth biomarkers. Anal Bioanal Chem 2018; 411:5405-5413. [PMID: 30382326 DOI: 10.1007/s00216-018-1440-9] [Citation(s) in RCA: 35] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2018] [Revised: 10/04/2018] [Accepted: 10/19/2018] [Indexed: 01/19/2023]
Abstract
Preterm birth (PTB) is defined as birth before the 37th week of pregnancy and results in 15 million early deliveries worldwide every year. Presently, there is no clinical test to determine PTB risk; however, a panel of nine biomarkers found in maternal blood serum has predictive power for a subsequent PTB. A significant step in creating a clinical diagnostic for PTB is designing an automated method to extract and purify these biomarkers from blood serum. Here, microfluidic devices with 45 μm × 50 μm cross-section channels were 3D printed with a built-in polymerization window to allow a glycidyl methacrylate monolith to be site-specifically polymerized within the channel. This monolith was then used as a solid support to attach antibodies for PTB biomarker extraction. Using these functionalized monoliths, it was possible to selectively extract a PTB biomarker, ferritin, from buffer and a human blood serum matrix. This is the first demonstration of monolith formation in a 3D printed microfluidic device for immunoaffinity extraction. Notably, this work is a crucial first step toward developing a 3D printed microfluidic clinical diagnostic for PTB risk.
Collapse
Affiliation(s)
- Ellen K Parker
- Department of Chemistry and Biochemistry, C100 BNSN, Brigham Young University, Provo, UT, 84602, USA
| | - Anna V Nielsen
- Department of Chemistry and Biochemistry, C100 BNSN, Brigham Young University, Provo, UT, 84602, USA
| | - Michael J Beauchamp
- Department of Chemistry and Biochemistry, C100 BNSN, Brigham Young University, Provo, UT, 84602, USA
| | - Haifa M Almughamsi
- Department of Chemistry and Biochemistry, C100 BNSN, Brigham Young University, Provo, UT, 84602, USA
| | - Jacob B Nielsen
- Department of Chemistry and Biochemistry, C100 BNSN, Brigham Young University, Provo, UT, 84602, USA
| | - Mukul Sonker
- Department of Chemistry and Biochemistry, C100 BNSN, Brigham Young University, Provo, UT, 84602, USA
| | - Hua Gong
- Department of Electrical and Computer Engineering, 450G EB, Brigham Young University, Provo, UT, 84602, USA
| | - Gregory P Nordin
- Department of Electrical and Computer Engineering, 450G EB, Brigham Young University, Provo, UT, 84602, USA
| | - Adam T Woolley
- Department of Chemistry and Biochemistry, C100 BNSN, Brigham Young University, Provo, UT, 84602, USA.
| |
Collapse
|
33
|
Highly efficient DNA extraction and purification from olive oil on a washable and reusable miniaturized device. Anal Chim Acta 2018; 1020:30-40. [DOI: 10.1016/j.aca.2018.02.079] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2017] [Revised: 02/19/2018] [Accepted: 02/23/2018] [Indexed: 01/21/2023]
|
34
|
Fabricating Microstructures on Glass for Microfluidic Chips by Glass Molding Process. MICROMACHINES 2018; 9:mi9060269. [PMID: 30424202 PMCID: PMC6187291 DOI: 10.3390/mi9060269] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2018] [Revised: 05/23/2018] [Accepted: 05/23/2018] [Indexed: 11/23/2022]
Abstract
Compared with polymer-based biochips, such as polydimethylsiloxane (PDMS), glass based chips have drawn much attention due to their high transparency, chemical stability, and good biocompatibility. This paper investigated the glass molding process (GMP) for fabricating microstructures of microfluidic chips. The glass material was D-ZK3. Firstly, a mold with protrusion microstructure was prepared and used to fabricate grooves to evaluate the GMP performance in terms of roughness and height. Next, the molds for fabricating three typical microfluidic chips, for example, diffusion mixer chip, flow focusing chip, and cell counting chip, were prepared and used to mold microfluidic chips. The analysis of mold wear was then conducted by the comparison of mold morphology, before and after the GMP, which indicated that the mold was suitable for GMP. Finally, in order to verify the performance of the molded chips by the GMP, a mixed microfluidic chip was chosen to conduct an actual liquid filling experiment. The study indicated that the fabricating microstructure of glass microfluidic chip could be finished in 12 min with good surface quality, thus, providing a promising method for achieving mass production of glass microfluidic chips in the future.
Collapse
|
35
|
Ghelich P, Salehi Z, Mohajerzedeh S, Jafarkhani M. Experimental and numerical study on a novel microfluidic method to fabricate curcumin loaded calcium alginate microfibres. CAN J CHEM ENG 2018. [DOI: 10.1002/cjce.23173] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Affiliation(s)
- Pejman Ghelich
- School of Chemical Engineering; College of Chemical Engineering; University of Tehran; 16 Azar Street Tehran Iran
| | - Zeinab Salehi
- School of Chemical Engineering; College of Chemical Engineering; University of Tehran; 16 Azar Street Tehran Iran
| | - Shams Mohajerzedeh
- School of Electrical and Computer Engineering, College of Electrical Engineering; University of Tehran; North Kargar Street Tehran Iran
| | - Mahboubeh Jafarkhani
- School of Chemical Engineering; College of Chemical Engineering; University of Tehran; 16 Azar Street Tehran Iran
| |
Collapse
|
36
|
Ly J, Ha NS, Cheung S, van Dam RM. Toward miniaturized analysis of chemical identity and purity of radiopharmaceuticals via microchip electrophoresis. Anal Bioanal Chem 2018; 410:2423-2436. [PMID: 29470664 PMCID: PMC6482050 DOI: 10.1007/s00216-018-0924-y] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2017] [Revised: 01/19/2018] [Accepted: 01/29/2018] [Indexed: 10/18/2022]
Abstract
Miniaturized synthesis of positron emission tomography (PET) tracers is poised to offer numerous advantages including reduced tracer production costs and increased availability of diverse tracers. While many steps of the tracer production process have been miniaturized, there has been relatively little development of microscale systems for the quality control (QC) testing process that is required by regulatory agencies to ensure purity, identity, and biological safety of the radiotracer before use in human subjects. Every batch must be tested, and in contrast with ordinary pharmaceuticals, the whole set of tests of radiopharmaceuticals must be completed within a short-period of time to minimize losses due to radioactive decay. By replacing conventional techniques with microscale analytical ones, it may be possible to significantly reduce instrument cost, conserve lab space, shorten analysis times, and streamline this aspect of PET tracer production. We focus in this work on miniaturizing the subset of QC tests for chemical identity and purity. These tests generally require high-resolution chromatographic separation prior to detection to enable the approach to be applied to many different tracers (and their impurities), and have not yet, to the best of our knowledge, been tackled in microfluidic systems. Toward this end, we previously explored the feasibility of using the technique of capillary electrophoresis (CE) as a replacement for the "gold standard" approach of using high-performance liquid chromatography (HPLC) since CE offers similar separating power, flexibility, and sensitivity, but can readily be implemented in a microchip format. Using a conventional CE system, we previously demonstrated the successful separation of non-radioactive version of a clinical PET tracer, 3'-deoxy-3'-fluorothymidine (FLT), from its known by-products, and the separation of the PET tracer 1-(2'-deoxy-2'-fluoro-β-D-arabinofuranosyl)-cytosine (D-FAC) from its α-isomer, with sensitivity nearly as good as HPLC. Building on this feasibility study, in this paper, we describe the first effort to miniaturize the chemical identity and purity tests by using microchip electrophoresis (MCE). The fully automated proof-of-concept system comprises a chip for sample injection, a separation capillary, and an optical detection chip. Using the same model compound (FLT and its known by-products), we demonstrate that samples can be injected, separated, and detected, and show the potential to match the performance of HPLC. Addition of a radiation detector in the future would enable analysis of radiochemical identity and purity in the same device. We envision that eventually this MCE method could be combined with other miniaturized QC tests into a compact integrated system for automated routine QC testing of radiopharmaceuticals in the future. Graphical abstract Miniaturized quality control (QC) testing of batches of radiopharmaceuticals via microfluidic analysis. The proof-of-concept hybrid microchip electrophoresis (MCE) device demonstrated the feasibility of achieving comparable performance to conventional analytical instruments (HPLC or CE) for chemical purity testing.
Collapse
Affiliation(s)
- Jimmy Ly
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Science, University of California Los Angeles, 420 Westwood Plaza, Los Angeles, CA, 90095-7227, USA
- Crump Institute for Molecular Imaging and Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles, 650 Charles E Young Dr., Los Angeles, CA, 90095-8352, USA
- Bioengineering and Therapeutic Sciences, UCSF, San Francisco, CA, 94158, USA
| | - Noel S Ha
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Science, University of California Los Angeles, 420 Westwood Plaza, Los Angeles, CA, 90095-7227, USA
- Crump Institute for Molecular Imaging and Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles, 650 Charles E Young Dr., Los Angeles, CA, 90095-8352, USA
| | - Shilin Cheung
- Crump Institute for Molecular Imaging and Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles, 650 Charles E Young Dr., Los Angeles, CA, 90095-8352, USA
- Trace-ability, Inc., 6160 Bristol Parkway Ste. 200, Culver City, CA, 90230, USA
| | - R Michael van Dam
- Department of Bioengineering, Henry Samueli School of Engineering and Applied Science, University of California Los Angeles, 420 Westwood Plaza, Los Angeles, CA, 90095-7227, USA.
- Crump Institute for Molecular Imaging and Department of Molecular and Medical Pharmacology, David Geffen School of Medicine, University of California Los Angeles, 650 Charles E Young Dr., Los Angeles, CA, 90095-8352, USA.
| |
Collapse
|
37
|
Rodríguez-Ruiz I, Babenko V, Martínez-Rodríguez S, Gavira JA. Protein separation under a microfluidic regime. Analyst 2017; 143:606-619. [PMID: 29214270 DOI: 10.1039/c7an01568b] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
Abstract
Lab-on-a-Chip (LoC), or micro-Total Analysis Systems (μTAS), is recognized as a powerful analytical technology with high capabilities, though end-user products for protein purification are still far from being available on the market. Remarkable progress has been achieved in the separation of nucleic acids and proteins using electrophoretic microfluidic devices, while pintsize devices have been developed for protein isolation according to miniaturized chromatography principles (size, charge, affinity, etc.). In this work, we review the latest advances in the fabrication of components, detection methods and commercial implementation for the separation of biological macromolecules based on microfluidic systems, with some critical remarks on the perspectives of their future development towards standardized microfluidic systems and protocols. An outlook on the current needs and future applications is also presented.
Collapse
Affiliation(s)
| | - V Babenko
- Laboratorio de Estudios Cristalograficos, Instituto Andaluz de Ciencias de la Tierra, CSIC-University of Granada, Avenida de las Palmeras 4, 18100 Armilla, Granada, Spain.
| | - S Martínez-Rodríguez
- Department of Biochemistry and Molecular Biology III and Immunology. University of Granada, Granada, Spain
| | - J A Gavira
- Laboratorio de Estudios Cristalograficos, Instituto Andaluz de Ciencias de la Tierra, CSIC-University of Granada, Avenida de las Palmeras 4, 18100 Armilla, Granada, Spain.
| |
Collapse
|
38
|
Evstrapov AA. Micro- and nanofluidic systems in devices for biological, medical and environmental research. ACTA ACUST UNITED AC 2017. [DOI: 10.1088/1742-6596/917/2/022002] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
39
|
Selectivity/Specificity Improvement Strategies in Surface-Enhanced Raman Spectroscopy Analysis. SENSORS 2017; 17:s17112689. [PMID: 29160798 PMCID: PMC5713634 DOI: 10.3390/s17112689] [Citation(s) in RCA: 41] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/28/2017] [Revised: 10/31/2017] [Accepted: 11/12/2017] [Indexed: 12/13/2022]
Abstract
Surface-enhanced Raman spectroscopy (SERS) is a powerful technique for the discrimination, identification, and potential quantification of certain compounds/organisms. However, its real application is challenging due to the multiple interference from the complicated detection matrix. Therefore, selective/specific detection is crucial for the real application of SERS technique. We summarize in this review five selective/specific detection techniques (chemical reaction, antibody, aptamer, molecularly imprinted polymers and microfluidics), which can be applied for the rapid and reliable selective/specific detection when coupled with SERS technique.
Collapse
|
40
|
Marques MP, Szita N. Bioprocess microfluidics: applying microfluidic devices for bioprocessing. Curr Opin Chem Eng 2017; 18:61-68. [PMID: 29276669 PMCID: PMC5727670 DOI: 10.1016/j.coche.2017.09.004] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Microfluidic devices as novel bioprocess development tools. Processes with stem cells, microbes and enzymes are viable in microfluidic devices. Microfluidic devices with integrated sensors provide high quality data. Laminar flow enables spatial and temporal control over transport phenomena. Standardization of devices required for automation and industrial uptake.
Scale-down approaches have long been applied in bioprocessing to resolve scale-up problems. Miniaturized bioreactors have thrived as a tool to obtain process relevant data during early-stage process development. Microfluidic devices are an attractive alternative in bioprocessing development due to the high degree of control over process variables afforded by the laminar flow, and the possibility to reduce time and cost factors. Data quality obtained with these devices is high when integrated with sensing technology and is invaluable for scale-translation and to assess the economical viability of bioprocesses. Microfluidic devices as upstream process development tools have been developed in the area of small molecules, therapeutic proteins, and cellular therapies. More recently, they have also been applied to mimic downstream unit operations.
Collapse
Affiliation(s)
- Marco Pc Marques
- Department of Biochemical Engineering, University College London, Bernard Katz Building, Gordon Street, London WC1H 0AH, United Kingdom
| | - Nicolas Szita
- Department of Biochemical Engineering, University College London, Bernard Katz Building, Gordon Street, London WC1H 0AH, United Kingdom
| |
Collapse
|
41
|
Man Y, Liang G, Li A, Pan L. Recent Advances in Mycotoxin Determination for Food Monitoring via Microchip. Toxins (Basel) 2017; 9:E324. [PMID: 29036884 PMCID: PMC5666371 DOI: 10.3390/toxins9100324] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Revised: 09/30/2017] [Accepted: 10/09/2017] [Indexed: 11/28/2022] Open
Abstract
Mycotoxins are one of the main factors impacting food safety. Mycotoxin contamination has threatened the health of humans and animals. Conventional methods for the detection of mycotoxins are gas chromatography (GC) or liquid chromatography (LC) coupled with mass spectrometry (MS), or enzyme-linked immunosorbent assay (ELISA). However, all these methods are time-consuming, require large-scale instruments and skilled technicians, and consume large amounts of hazardous regents and solvents. Interestingly, a microchip requires less sample consumption and short analysis time, and can realize the integration, miniaturization, and high-throughput detection of the samples. Hence, the application of a microchip for the detection of mycotoxins can make up for the deficiency of the conventional detection methods. This review focuses on the application of a microchip to detect mycotoxins in foods. The toxicities of mycotoxins and the materials of the microchip are firstly summarized in turn. Then the application of a microchip that integrates various kinds of detection methods (optical, electrochemical, photo-electrochemical, and label-free detection) to detect mycotoxins is reviewed in detail. Finally, challenges and future research directions in the development of a microchip to detect mycotoxins are previewed.
Collapse
Affiliation(s)
- Yan Man
- Beijing Research Center for Agricultural Standards and Testing, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Risk Assessment Lab for Agro-products, Ministry of Agriculture of the People's Republic of China, Beijing 100125, China.
- Beijing Municipal Key Laboratory of Agriculture Environment Monitoring, Beijing 100097, China.
| | - Gang Liang
- Beijing Research Center for Agricultural Standards and Testing, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Risk Assessment Lab for Agro-products, Ministry of Agriculture of the People's Republic of China, Beijing 100125, China.
- Beijing Municipal Key Laboratory of Agriculture Environment Monitoring, Beijing 100097, China.
| | - An Li
- Beijing Research Center for Agricultural Standards and Testing, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Risk Assessment Lab for Agro-products, Ministry of Agriculture of the People's Republic of China, Beijing 100125, China.
- Beijing Municipal Key Laboratory of Agriculture Environment Monitoring, Beijing 100097, China.
| | - Ligang Pan
- Beijing Research Center for Agricultural Standards and Testing, Beijing Academy of Agriculture and Forestry Sciences, Beijing 100097, China.
- Risk Assessment Lab for Agro-products, Ministry of Agriculture of the People's Republic of China, Beijing 100125, China.
- Beijing Municipal Key Laboratory of Agriculture Environment Monitoring, Beijing 100097, China.
| |
Collapse
|
42
|
Podgornik A, Hamachi M, Isakari Y, Yoshimoto N, Yamamoto S. Effect of pore size on performance of monolithic tube chromatography of large biomolecules. Electrophoresis 2017; 38:2892-2899. [DOI: 10.1002/elps.201700258] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 08/14/2017] [Accepted: 08/14/2017] [Indexed: 02/05/2023]
Affiliation(s)
- Ales Podgornik
- Faculty of Chemistry and Chemical Technology; University of Ljubljana; Ljubljana Slovenia
- Center of Excellence; COBIK; Ajdovščina Slovenia
| | - Masataka Hamachi
- Bio-Process Engineering Laboratory, Graduate School of Medicine; Yamaguchi University; Ube Japan
| | - Yu Isakari
- Bio-Process Engineering Laboratory, Graduate School of Medicine; Yamaguchi University; Ube Japan
| | - Noriko Yoshimoto
- Bio-Process Engineering Laboratory, Graduate School of Medicine; Yamaguchi University; Ube Japan
- Biomedical Engineering Center (YUBEC); Yamaguchi University; Ube Japan
| | - Shuichi Yamamoto
- Bio-Process Engineering Laboratory, Graduate School of Medicine; Yamaguchi University; Ube Japan
- Biomedical Engineering Center (YUBEC); Yamaguchi University; Ube Japan
| |
Collapse
|
43
|
Lee AWH, Gates BD. Covalent Surface Modification of Silicon Oxides with Alcohols in Polar Aprotic Solvents. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2017; 33:8707-8715. [PMID: 28556659 DOI: 10.1021/acs.langmuir.7b00820] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Alcohol-based monolayers were successfully formed on the surfaces of silicon oxides through reactions performed in polar aprotic solvents. Monolayers prepared from alcohol-based reagents have been previously introduced as an alternative approach to covalently modify the surfaces of silicon oxides. These reagents are readily available, widely distributed, and are minimally susceptible to side reactions with ambient moisture. A limitation of using alcohol-based compounds is that previous reactions required relatively high temperatures in neat solutions, which can degrade some alcohol compounds or could lead to other unwanted side reactions during the formation of the monolayers. To overcome these challenges, we investigate the condensation reaction of alcohols on silicon oxides carried out in polar aprotic solvents. In particular, propylene carbonate has been identified as a polar aprotic solvent that is relatively nontoxic, readily accessible, and can facilitate the formation of alcohol-based monolayers. We have successfully demonstrated this approach for tuning the surface chemistry of silicon oxide surfaces with a variety of alcohol containing compounds. The strategy introduced in this research can be utilized to create silicon oxide surfaces with hydrophobic, oleophobic, or charged functionalities.
Collapse
Affiliation(s)
- Austin W H Lee
- Department of Chemistry, Simon Fraser University , 8888 University Drive, Burnaby, British Columbia V5A 1S6, Canada
| | - Byron D Gates
- Department of Chemistry, Simon Fraser University , 8888 University Drive, Burnaby, British Columbia V5A 1S6, Canada
| |
Collapse
|
44
|
Development of a metal/chelate polyhydroxyethylmethacrylate monolith capillary for selective depletion of immunoglobulin G from human plasma for proteomics. J Chromatogr A 2017; 1517:117-125. [DOI: 10.1016/j.chroma.2017.08.047] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Revised: 07/17/2017] [Accepted: 08/17/2017] [Indexed: 02/03/2023]
|
45
|
Roy T, Szuttor K, Smiatek J, Holm C, Hardt S. Electric-field-induced stretching of surface-tethered polyelectrolytes in a microchannel. Phys Rev E 2017; 96:032503. [PMID: 29346871 DOI: 10.1103/physreve.96.032503] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2017] [Indexed: 06/07/2023]
Abstract
We study the stretching of a surface-tethered polyelectrolyte confined between parallel surfaces under the application of a dc electric field. We explore the influence of the electric-field strength, the length of the polyelectrolyte, and the degree of confinement on the conformation of the polyelectrolyte by single-molecule experiments and coarse-grained coupled lattice-Boltzmann molecular-dynamics simulations. The fractional extension of the polyelectrolyte is found to be a universal function of the product of the applied electric field and the molecular contour length, which is explained by simple scaling arguments. The degree of confinement does not have any significant influence on the stretching. We also confirm that an electrohydrodynamic equivalence principle relating the stretching in an electric field to that in a flow field is applicable.
Collapse
Affiliation(s)
- Tamal Roy
- Institute for Nano- and Microfluidics, Technische Universität Darmstadt, 64287 Darmstadt, Germany
| | - Kai Szuttor
- Institut für Computerphysik, Universität Stuttgart, 70569 Stuttgart, Germany
| | - Jens Smiatek
- Institut für Computerphysik, Universität Stuttgart, 70569 Stuttgart, Germany
| | - Christian Holm
- Institut für Computerphysik, Universität Stuttgart, 70569 Stuttgart, Germany
| | - Steffen Hardt
- Institute for Nano- and Microfluidics, Technische Universität Darmstadt, 64287 Darmstadt, Germany
| |
Collapse
|
46
|
Herringbone-like hydrodynamic structures in microchannels: A CFD model to evaluate the enhancement of surface binding. Med Eng Phys 2017; 48:62-67. [PMID: 28802780 DOI: 10.1016/j.medengphy.2017.07.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2017] [Revised: 06/17/2017] [Accepted: 07/12/2017] [Indexed: 10/19/2022]
Abstract
Selected adsorption efficiency of a molecule in solution in a microchannel is strongly influenced by the convective/diffusive mass transport phenomena that supply the target molecule to the adsorption surface. In a standard microchannel with a rectangular cross section, laminar flow regime limits the fluid mixing, thus suggesting that mass transport conditions can be improved by the introduction of herringbone-like structures. Tuning of these geometrical patterns increases the concentration gradient of the target molecule at the adsorption surface. A computational fluid dynamic (CFD) study was performed to evaluate the relation between the geometrical herringbone patterns and the concentration gradient improvement in a 14 mm long microchannel. The results show that the inhomogeneity of the concentration gradient can provide an improved and localized adsorption under specific geometrical features, which can be tuned in order to adapt the adsorption pattern to the specific assay requirements.
Collapse
|
47
|
Recent advances in microfluidic sample preparation and separation techniques for molecular biomarker analysis: A critical review. Anal Chim Acta 2017; 986:1-11. [PMID: 28870312 DOI: 10.1016/j.aca.2017.07.043] [Citation(s) in RCA: 98] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2017] [Revised: 07/07/2017] [Accepted: 07/13/2017] [Indexed: 12/23/2022]
Abstract
Microfluidics is a vibrant and expanding field that has the potential for solving many analytical challenges. Microfluidics show promise to provide rapid, inexpensive, efficient, and portable diagnostic solutions that can be used in resource-limited settings. Researchers have recently reported various microfluidic platforms for biomarker analysis applications. Sample preparation processes like purification, preconcentration and labeling have been characterized on-chip. Additionally, improvements in microfluidic separation techniques have been reported for molecular biomarkers. This review critically evaluates microfluidic sample preparation platforms and separation methods for biomarker analysis reported in the last two years. Key advances in device operation and ability to process different sample matrices in a variety of device materials are highlighted. Finally, current needs and potential future directions for microfluidic device development to realize its full diagnostic potential are discussed.
Collapse
|
48
|
Viefhues M, Eichhorn R. DNA dielectrophoresis: Theory and applications a review. Electrophoresis 2017; 38:1483-1506. [PMID: 28306161 DOI: 10.1002/elps.201600482] [Citation(s) in RCA: 46] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2016] [Revised: 03/07/2017] [Accepted: 03/08/2017] [Indexed: 01/24/2023]
Abstract
Dielectrophoresis is the migration of an electrically polarizable particle in an inhomogeneous electric field. This migration can be exploited for several applications with (bio)molecules or cells. Dielectrophoresis is a noninvasive technique; therefore, it is very convenient for (selective) manipulation of (bio)molecules or cells. In this review, we will focus on DNA dielectrophoresis as this technique offers several advantages in trapping and immobilization, separation and purification, and analysis of DNA molecules. We present and discuss the underlying theory of the most important forces that have to be considered for applications with dielectrophoresis. Moreover, a review of DNA dielectrophoresis applications is provided to present the state-of-the-art and to offer the reader a perspective of the advances and current limitations of DNA dielectrophoresis.
Collapse
Affiliation(s)
- Martina Viefhues
- Experimental Biophysics and Applied Nanoscience, Faculty of Physics, Bielefeld University, Bielefeld, Germany
| | - Ralf Eichhorn
- Nordita, Royal Institute of Technology and Stockholm University, Stockholm, Sweden
| |
Collapse
|
49
|
Andrejčič M, Podgornik A. Effect of pressure drop model implemented for description of pressure drop on chromatographic monolith on estimated adsorbed layer thickness. Chem Eng Sci 2017. [DOI: 10.1016/j.ces.2016.12.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
|
50
|
Breadmore MC, Wuethrich A, Li F, Phung SC, Kalsoom U, Cabot JM, Tehranirokh M, Shallan AI, Abdul Keyon AS, See HH, Dawod M, Quirino JP. Recent advances in enhancing the sensitivity of electrophoresis and electrochromatography in capillaries and microchips (2014–2016). Electrophoresis 2016; 38:33-59. [DOI: 10.1002/elps.201600331] [Citation(s) in RCA: 79] [Impact Index Per Article: 8.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2016] [Revised: 08/09/2016] [Accepted: 08/10/2016] [Indexed: 01/02/2023]
Affiliation(s)
- Michael C. Breadmore
- Australian Centre of Research on Separation Science, School of Physical Science University of Tasmania Hobart Tasmania Australia
- ARC Centre of Excellence for Electromaterials Science, School of Physical Science University of Tasmania Hobart Tasmania Australia
- ASTech, ARC Training Centre for Portable Analytical Separation Technologies, School of Physical Science University of Tasmania Hobart Tasmania Australia
| | - Alain Wuethrich
- Australian Centre of Research on Separation Science, School of Physical Science University of Tasmania Hobart Tasmania Australia
| | - Feng Li
- Australian Centre of Research on Separation Science, School of Physical Science University of Tasmania Hobart Tasmania Australia
| | - Sui Ching Phung
- Australian Centre of Research on Separation Science, School of Physical Science University of Tasmania Hobart Tasmania Australia
| | - Umme Kalsoom
- Australian Centre of Research on Separation Science, School of Physical Science University of Tasmania Hobart Tasmania Australia
| | - Joan M. Cabot
- Australian Centre of Research on Separation Science, School of Physical Science University of Tasmania Hobart Tasmania Australia
- ARC Centre of Excellence for Electromaterials Science, School of Physical Science University of Tasmania Hobart Tasmania Australia
| | - Masoomeh Tehranirokh
- ASTech, ARC Training Centre for Portable Analytical Separation Technologies, School of Physical Science University of Tasmania Hobart Tasmania Australia
| | - Aliaa I. Shallan
- Department of Analytical Chemistry, Faculty of Pharmacy Helwan University Cairo Egypt
| | - Aemi S. Abdul Keyon
- Department of Chemistry, Faculty of Science Universiti Teknologi Malaysia Johor Bahru Johor Malaysia
| | - Hong Heng See
- Department of Chemistry, Faculty of Science Universiti Teknologi Malaysia Johor Bahru Johor Malaysia
- Centre for Sustainable Nanomaterials, Ibnu Sina Institute for Scientific and industrial Research Universiti Teknologi Malaysia Johor Bahru Johor Malaysia
| | - Mohamed Dawod
- Department of Chemistry University of Michigan Ann Arbor MI USA
| | - Joselito P. Quirino
- Australian Centre of Research on Separation Science, School of Physical Science University of Tasmania Hobart Tasmania Australia
| |
Collapse
|