1
|
Zhang Y, Liu T, Wang X, He M, Xu X, Feng X, Zhang F. Design and preparation of novel magnetic covalent organic framework for the simultaneous preconcentration and sensitive determination of six aflatoxins in food samples. Food Chem 2025; 471:142702. [PMID: 39788022 DOI: 10.1016/j.foodchem.2024.142702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2024] [Revised: 11/03/2024] [Accepted: 12/27/2024] [Indexed: 01/12/2025]
Abstract
An innovative core-shell covalent organic framework (COF), Fe3O4@COF (ETTBA-ND), was synthesized through a facile and energy-efficient method. This adsorbent facilitated magnetic solid phase extraction (MSPE) of six AFs prior to LC-MS/MS analysis, achieving one-step purification and enrichment in food matrices. The successful synthesis of the adsorbent was confirmed using various techniques, with adsorption capacities ranging from 46.7 mg/g to 52.3 mg/g. The adsorbent exhibited exceptional adsorption performance in real samples, with recoveries ranging from 80.3 % to 105.6 %, and notable reusability for more than seven cycles. The adsorption mechanism was investigated by density-functional theory and attributed to synergetic effects involving electrostatic and π-π stacking interactions. HPLC-MS/MS quantification revealed strong linear relationships within the 0.01-100 μg/kg range (R2 > 0.9983). The limits of detection ranged from 0.0016 μg/kg to 0.0099 μg/kg, indicating high sensitivity. The newly constructed COF adsorbents exhibit considerable potential for diverse applications in analytical fields that target various hazardous substances.
Collapse
Affiliation(s)
- Yixin Zhang
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China; Key Laboratory of Food Quality and Safety for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China; School of Pharmacy China Medical University, Shenyang 110122, Liaoning, China
| | - Tong Liu
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China; Key Laboratory of Food Quality and Safety for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Xiujuan Wang
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China; Key Laboratory of Food Quality and Safety for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Muyi He
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China; Key Laboratory of Food Quality and Safety for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Xiuli Xu
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China; Key Laboratory of Food Quality and Safety for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China
| | - Xuesong Feng
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China; School of Pharmacy China Medical University, Shenyang 110122, Liaoning, China
| | - Feng Zhang
- Institute of Food Safety, Chinese Academy of Inspection and Quarantine, Beijing 100176, China; Key Laboratory of Food Quality and Safety for State Market Regulation, Chinese Academy of Inspection and Quarantine, Beijing 100176, China.
| |
Collapse
|
2
|
Emamiamin A, Shariati Pour SR, Serra T, Calabria D, Varone M, Di Nardo F, Guardigli M, Anfossi L, Baggiani C, Zangheri M, Mirasoli M. New Frontiers for the Early Diagnosis of Cancer: Screening miRNAs Through the Lateral Flow Assay Method. BIOSENSORS 2025; 15:238. [PMID: 40277551 PMCID: PMC12024991 DOI: 10.3390/bios15040238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2025] [Revised: 03/31/2025] [Accepted: 04/05/2025] [Indexed: 04/26/2025]
Abstract
MicroRNAs (miRNAs), which circulate in the serum and plasma, play a role in several biological processes, and their levels in body fluids are associated with the pathogenesis of various diseases, including different types of cancer. For this reason, miRNAs are considered promising candidates as biomarkers for diagnostic purposes, enabling the early detection of pathological onset and monitoring drug responses during therapy. However, current methods for miRNA quantification, such as northern blotting, isothermal amplification, RT-PCR, microarrays, and next-generation sequencing, are limited by their reliance on centralized laboratories, high costs, and the need for specialized personnel. Consequently, the development of sensitive, simple, and one-step analytical techniques for miRNA detection is highly desirable, particularly given the importance of early diagnosis and prompt treatment in cases of cancer. Lateral flow assays (LFAs) are among the most attractive point-of-care (POC) devices for healthcare applications. These systems allow for the rapid and straightforward detection of analytes using low-cost setups that are accessible to a wide audience. This review focuses on LFA-based methods for detecting and quantifying miRNAs associated with the diagnosis of various cancers, with particular emphasis on sensitivity enhancements achieved through the application of different labels and detection systems. Early, non-invasive detection of these diseases through the quantification of tailored biomarkers can significantly reduce mortality, improve survival rates, and lower treatment costs.
Collapse
Affiliation(s)
- Afsaneh Emamiamin
- Department of Chemistry “Giacomo Ciamician”, Alma Mater Studiorum, University of Bologna, Tecnopolo di Rimini, Via Dario Campana 71, I-47922 Rimini, Italy; (A.E.); (S.R.S.P.)
| | - Seyedeh Rojin Shariati Pour
- Department of Chemistry “Giacomo Ciamician”, Alma Mater Studiorum, University of Bologna, Tecnopolo di Rimini, Via Dario Campana 71, I-47922 Rimini, Italy; (A.E.); (S.R.S.P.)
| | - Thea Serra
- Department of Chemistry, University of Turin, Via P. Giuria 5, I-10125 Turin, Italy; (T.S.); (F.D.N.); (L.A.); (C.B.)
| | - Donato Calabria
- Department of Chemistry “Giacomo Ciamician”, Alma Mater Studiorum, University of Bologna, Via Francesco Selmi 2, I-40126 Bologna, Italy; (D.C.); (M.V.); (M.G.)
- Interdepartmental Centre for Industrial Aerospace Research (CIRI AEROSPACE), Alma Mater Studiorum—University of Bologna, Via Baldassarre Canaccini 12, I-47121 Forlì, Italy
| | - Marta Varone
- Department of Chemistry “Giacomo Ciamician”, Alma Mater Studiorum, University of Bologna, Via Francesco Selmi 2, I-40126 Bologna, Italy; (D.C.); (M.V.); (M.G.)
| | - Fabio Di Nardo
- Department of Chemistry, University of Turin, Via P. Giuria 5, I-10125 Turin, Italy; (T.S.); (F.D.N.); (L.A.); (C.B.)
| | - Massimo Guardigli
- Department of Chemistry “Giacomo Ciamician”, Alma Mater Studiorum, University of Bologna, Via Francesco Selmi 2, I-40126 Bologna, Italy; (D.C.); (M.V.); (M.G.)
- Interdepartmental Centre for Industrial Aerospace Research (CIRI AEROSPACE), Alma Mater Studiorum—University of Bologna, Via Baldassarre Canaccini 12, I-47121 Forlì, Italy
- Interdepartmental Centre for Industrial Research in Renewable Resources, Environment, Sea, and Energy (CIRI FRAME), Alma Mater Studiorum—University of Bologna, Via St. Alberto 163, I-48123 Ravenna, Italy
| | - Laura Anfossi
- Department of Chemistry, University of Turin, Via P. Giuria 5, I-10125 Turin, Italy; (T.S.); (F.D.N.); (L.A.); (C.B.)
| | - Claudio Baggiani
- Department of Chemistry, University of Turin, Via P. Giuria 5, I-10125 Turin, Italy; (T.S.); (F.D.N.); (L.A.); (C.B.)
| | - Martina Zangheri
- Department of Chemistry “Giacomo Ciamician”, Alma Mater Studiorum, University of Bologna, Tecnopolo di Rimini, Via Dario Campana 71, I-47922 Rimini, Italy; (A.E.); (S.R.S.P.)
- Interdepartmental Centre for Industrial Agrofood Research (CIRI AGRO), Alma Mater Studiorum—University of Bologna, Via Quinto Bucci 336, I-47521 Cesena, Italy
| | - Mara Mirasoli
- Department of Chemistry “Giacomo Ciamician”, Alma Mater Studiorum, University of Bologna, Tecnopolo di Rimini, Via Dario Campana 71, I-47922 Rimini, Italy; (A.E.); (S.R.S.P.)
- Interdepartmental Centre for Industrial Aerospace Research (CIRI AEROSPACE), Alma Mater Studiorum—University of Bologna, Via Baldassarre Canaccini 12, I-47121 Forlì, Italy
- Interdepartmental Centre for Industrial Research in Renewable Resources, Environment, Sea, and Energy (CIRI FRAME), Alma Mater Studiorum—University of Bologna, Via St. Alberto 163, I-48123 Ravenna, Italy
| |
Collapse
|
3
|
Li W, Xu Z, He Q, Pan J, Zhang Y, El-Sheikh ESA, Hammock BD, Li D. Nanobody-Based Immunoassays for the Detection of Food Hazards-A Review. BIOSENSORS 2025; 15:183. [PMID: 40136980 PMCID: PMC11939871 DOI: 10.3390/bios15030183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/17/2025] [Revised: 03/10/2025] [Accepted: 03/12/2025] [Indexed: 03/27/2025]
Abstract
Food safety remains a significant global challenge that affects human health. Various hazards, including microbiological and chemical threats, can compromise food safety throughout the supply chain. To address food safety issues and ensure public health, it is necessary to adopt rapid, accurate, and highly specific detection methods. Immunoassays are considered to be an effective method for the detection of highly sensitive biochemical indicators and provide an efficient platform for the identification of food hazards. In immunoassays, antibodies function as the primary recognition elements. Nanobodies have significant potential as valuable biomolecules in diagnostic applications. Their distinctive physicochemical and structural characteristics make them excellent candidates for the development of reliable diagnostic assays, and as promising alternatives to monoclonal and polyclonal antibodies. Herein, we summarize a comprehensive overview of the status and prospects of nanobody-based immunoassays in ensuring food safety. First, we begin with a historical perspective on the development of nanobodies and their unique characteristics. Subsequently, we explore the definitions and boundaries of immunoassays and immunosensors, before discussing the potential applications of nanobody-based immunoassays in food safety testing that have emerged over the past five years, and follow the different immunoassays, highlighting their advantages over traditional detection methods. Finally, the directions and challenges of nanobody-based immunoassays in food safety are discussed. Due to their remarkable sensitivity, specificity and versatility, nanobody-based immunoassays hold great promise in revolutionizing food safety testing and ensuring public health and well-being.
Collapse
Affiliation(s)
- Wenkai Li
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China; (W.L.); (Z.X.); (Q.H.); (J.P.); (Y.Z.)
- Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Hangzhou 310058, China
| | - Zhihao Xu
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China; (W.L.); (Z.X.); (Q.H.); (J.P.); (Y.Z.)
- Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Hangzhou 310058, China
| | - Qiyi He
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China; (W.L.); (Z.X.); (Q.H.); (J.P.); (Y.Z.)
- Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Hangzhou 310058, China
| | - Junkang Pan
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China; (W.L.); (Z.X.); (Q.H.); (J.P.); (Y.Z.)
- Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Hangzhou 310058, China
| | - Yijia Zhang
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China; (W.L.); (Z.X.); (Q.H.); (J.P.); (Y.Z.)
- Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Hangzhou 310058, China
| | | | - Bruce D. Hammock
- Department of Entomology and Nematology and UCD Comprehensive Cancer Center, University of California Davis, Davis, CA 95616, USA
| | - Dongyang Li
- College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou 310058, China; (W.L.); (Z.X.); (Q.H.); (J.P.); (Y.Z.)
- Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Hangzhou 310058, China
| |
Collapse
|
4
|
Shahrajabian MH, Sun W. Study Rapid, Quantitative, and Simultaneous Detection of Drug Residues and Immunoassay in Chickens. Rev Recent Clin Trials 2025; 20:2-17. [PMID: 39171469 DOI: 10.2174/0115748871305331240724104132] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2024] [Revised: 04/28/2024] [Accepted: 06/13/2024] [Indexed: 08/23/2024]
Abstract
Different levels of residual drugs can be monitored within a relatively safe range without causing harm to human health if the appropriate dosing methodology is considered and the drug withdrawal period is controlled during poultry and livestock raising. Antimicrobials are factors that can suppress the growth of microorganisms, and antibiotic residues in livestock farming have been considered as a potential cause of antimicrobial resistance in animals and humans. Antimicrobial drug resistance is associated with the capability of a microorganism to survive the inhibitory effects of the antimicrobial components. Antibiotic residue presence in chicken is a human health concern due to its negative effects on consumer health. Neglected aspects related to the application of veterinary drugs may threaten the safety of both humans and animals, as well as their environment. The detection of chemical contaminants is essential to ensure food quality. The most important antibiotic families used in veterinary medicines are β-lactams (penicillins and cephalosporins), tetracyclines, chloramphenicols, macrolides, spectinomycin, lincosamide, sulphonamides, nitrofuranes, nitroimidazoles, trimethoprim, polymyxins, quinolones, and macrocyclics (glycopeptides, ansamycins, and aminoglycosides). Antibiotic residue presence is the main contributor to the development of antibiotic resistance, which is considered a chief concern for both human and animal health worldwide. The incorrect application and misuse of antibiotics carry the risk of the presence of residues in the edible tissues of the chicken, which can cause allergies and toxicity in hypersensitive consumers. The enforcement of the regulation of food safety depends on efficacious monitoring of antimicrobial residues in the foodstuff. In this review, we have explored the rapid detection of drug residues in broilers.
Collapse
Affiliation(s)
- Mohamad Hesam Shahrajabian
- National Key Laboratory of Agricultural Microbiology, Biotechnology Research Institute, Chinese Academy of Agricultural Sciences, Beijing, 100086, China
| | - Wenli Sun
- National Key Laboratory of Agricultural Microbiology, Biotechnology Research Institute, Chinese Academy of Agricultural Sciences, Beijing, 100086, China
| |
Collapse
|
5
|
Ozcelikay G, Cetinkaya A, Kaya SI, Yence M, Canavar Eroğlu PE, Unal MA, Ozkan SA. Novel Sensor Approaches of Aflatoxins Determination in Food and Beverage Samples. Crit Rev Anal Chem 2024; 54:982-1001. [PMID: 35917408 DOI: 10.1080/10408347.2022.2105136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/16/2022]
Abstract
The rapid quantification of toxins in food and beverage products has become a significant issue in overcoming and preventing many life-threatening diseases. Aflatoxin-contaminated food is one of the reasons for primary liver cancer and induces some tumors and cancer types. Advancements in biosensors technology have brought out different analysis methods. Therefore, the sensing performance has been improved for agricultural and beverage industries or food control processes. Nanomaterials are widely used for the enhancement of sensing performance. The enzymes, molecularly imprinted polymers (MIP), antibodies, and aptamers can be used as biorecognition elements. The transducer part of the biosensor can be selected, such as optical, electrochemical, and mass-based. This review explains the classification of major types of aflatoxins, the importance of nanomaterials, electrochemical, optical biosensors, and QCM and their applications for the determination of aflatoxins.
Collapse
Affiliation(s)
- Goksu Ozcelikay
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Yenimahalle, Ankara, Turkey
| | - Ahmet Cetinkaya
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Yenimahalle, Ankara, Turkey
| | - S Irem Kaya
- Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Kecioren, Ankara, Turkey
| | - Merve Yence
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Yenimahalle, Ankara, Turkey
| | | | | | - Sibel A Ozkan
- Department of Analytical Chemistry, Faculty of Pharmacy, Ankara University, Yenimahalle, Ankara, Turkey
| |
Collapse
|
6
|
Máčala J, Makhneva E, Hlaváček A, Kopecký M, Gorris HH, Skládal P, Farka Z. Upconversion Nanoparticle-Based Dot-Blot Immunoassay for Quantitative Biomarker Detection. Anal Chem 2024; 96:10237-10245. [PMID: 38870418 PMCID: PMC11209662 DOI: 10.1021/acs.analchem.4c00837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2024] [Revised: 05/14/2024] [Accepted: 06/03/2024] [Indexed: 06/15/2024]
Abstract
Dot-blot immunoassays are widely used for the user-friendly detection of clinical biomarkers. However, the majority of dot-blot assays have only limited sensitivity and are only used for qualitative or semiquantitative analysis. To overcome this limitation, we have employed labels based on photon-upconversion nanoparticles (UCNPs) that exhibit anti-Stokes luminescence and can be detected without optical background interference. First, the dot-blot immunoassay on a nitrocellulose membrane was optimized for the quantitative analysis of human serum albumin (HSA), resulting in a limit of detection (LOD) of 0.19 ng/mL and a signal-to-background ratio (S/B) of 722. Commercial quantum dots were used as a reference label, reaching the LOD of 4.32 ng/mL and the S/B of 3, clearly indicating the advantages of UCNPs. In addition, the potential of UCNP-based dot-blot for real sample analysis was confirmed by analyzing spiked urine samples, reaching the LOD of 0.24 ng/mL and recovery rates from 79 to 123%. Furthermore, we demonstrated the versatility and robustness of the assay by adapting it to the detection of two other clinically relevant biomarkers, prostate-specific antigen (PSA) and cardiac troponin (cTn), reaching the LODs in spiked serum of 9.4 pg/mL and 0.62 ng/mL for PSA and cTn, respectively. Finally, clinical samples of patients examined for prostate cancer were analyzed, achieving a strong correlation with the reference electrochemiluminescence immunoassay (recovery rates from 89 to 117%). The achieved results demonstrate that UCNPs are highly sensitive labels that enable the development of dot-blot immunoassays for quantitative analysis of low-abundance biomarkers.
Collapse
Affiliation(s)
- Jakub Máčala
- Department
of Biochemistry, Faculty of Science, Masaryk
University, Kamenice 5, 625 00 Brno, Czech Republic
| | - Ekaterina Makhneva
- Department
of Biochemistry, Faculty of Science, Masaryk
University, Kamenice 5, 625 00 Brno, Czech Republic
| | - Antonín Hlaváček
- Institute
of Analytical Chemistry of the Czech Academy of Sciences, Veveří 97, 602 00 Brno, Czech Republic
| | - Martin Kopecký
- Department
of Biochemistry, Faculty of Science, Masaryk
University, Kamenice 5, 625 00 Brno, Czech Republic
| | - Hans H. Gorris
- Department
of Biochemistry, Faculty of Science, Masaryk
University, Kamenice 5, 625 00 Brno, Czech Republic
| | - Petr Skládal
- Department
of Biochemistry, Faculty of Science, Masaryk
University, Kamenice 5, 625 00 Brno, Czech Republic
| | - Zdeněk Farka
- Department
of Biochemistry, Faculty of Science, Masaryk
University, Kamenice 5, 625 00 Brno, Czech Republic
| |
Collapse
|
7
|
Xu D, Zhang J, Luo Z, Zhao Y, Zhu Y, Yang H, Zhou Y. Ratiometric fluorescence and absorbance dual-model immunoassay based on 2,3-diaminophenazine and carbon dots for detecting Aflatoxin B1. Food Chem 2024; 439:138125. [PMID: 38061303 DOI: 10.1016/j.foodchem.2023.138125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2023] [Revised: 11/27/2023] [Accepted: 11/29/2023] [Indexed: 01/10/2024]
Abstract
In this work, a dual-model immunoassay for detecting Aflatoxin B1 (AFB1) was developed based on 2,3-diaminophenazine (DAP) and carbon dots (CDs). Under the catalysis of horseradish peroxidase (HRP), the o-phthalylenediamine (OPD) was oxidized to DAP which had a yellow color and intense fluorescence. The color changes form colorless to yellow was used to design absorbance model immunoassay. Meanwhile, the absorption spectrum of DAP overlapped with the emission spectrum of CDs which caused the fluorescence of CDs to be quenched. The fluorescence changes of DAP and CDs were used to develop ratiometric fluorescence immunoassay. The dual-model immunoassay showed excellent sensitivity with the limits of detection (LODs) of 0.013 ng/mL for fluorescence mode and 0.062 ng/mL for absorbance mode. Meanwhile, both models exhibited great selectivity for AFB1. Additionally, the recovery rates suggested the proposed dual-model immunoassay had great potential in actual samples detection.
Collapse
Affiliation(s)
- Die Xu
- College of Life Science, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei 434025, China
| | - Junxiang Zhang
- College of Life Science, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei 434025, China
| | - Zhenzhen Luo
- College of Life Science, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei 434025, China
| | - Yanan Zhao
- College of Animal Science and Technology, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei 434025, China
| | - Yuanhua Zhu
- College of Animal Science and Technology, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei 434025, China
| | - Hualin Yang
- College of Life Science, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei 434025, China.
| | - Yu Zhou
- College of Life Science, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei 434025, China; College of Animal Science and Technology, Yangtze University, 266 Jingmi Road, Jingzhou, Hubei 434025, China.
| |
Collapse
|
8
|
Zhu F, Yu H, Zhao Q. CRISPR/Cas12a-Amplified Aptamer Switch Microplate Assay for Small Molecules. Anal Chem 2024; 96:6853-6859. [PMID: 38646918 DOI: 10.1021/acs.analchem.4c01452] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/23/2024]
Abstract
The presence of small molecule contaminants such as mycotoxins and heavy metals in foods and the environment causes a serious threat to human health and huge economic losses. The development of simple, rapid, sensitive, and on-site methods for small molecule pollutant detection is highly demanded. Here, combining the advantages of structure-switchable aptamer-mediated signal conversion and CRISPR/Cas12a-based signal amplification, we developed a CRISPR/Cas12a-amplified aptamer switch assay on a microplate for sensitive small molecule detection. In this assay, a short DNA strand complementary to the aptamer (cDNA) is immobilized on a microplate, which can capture the aptamer-linked active DNA probe (Apt-acDNA) in the sample solution when the target is absent. With the addition of the Cas12a reporter system, the captured Apt-acDNA probes activate Cas12a to indiscriminately cleave fluorescent DNA substrates, producing a high fluorescence signal. When the target is present, the Apt-acDNA probe specifically binds to the target rather than hybridizing with cDNA on the microplate, and the fluorescence signal is reduced. The analytical performance of our method was demonstrated by the detection of two highly toxic pollutants, aflatoxin B1 (AFB1) and cadmium ion (Cd2+), as examples. The assay exhibited good selectivity and high sensitivity, with detection limits of 31 pM AFB1 and 3.9 nM Cd2+. It also allowed the detection of targets in the actual sample matrix. With the general signal conversion strategy, this method can be used to detect other targets by simply changing the aptamer and cDNA, showing potential practical applications in broad fields.
Collapse
Affiliation(s)
- Fengxi Zhu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Hao Yu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
- University of Chinese Academy of Sciences, Beijing 100049, China
| | - Qiang Zhao
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
- University of Chinese Academy of Sciences, Beijing 100049, China
- School of Environment, Hangzhou Institute for Advanced Study, UCAS, Hangzhou 310024, China
| |
Collapse
|
9
|
Farka Z, Brandmeier JC, Mickert MJ, Pastucha M, Lacina K, Skládal P, Soukka T, Gorris HH. Nanoparticle-Based Bioaffinity Assays: From the Research Laboratory to the Market. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2024; 36:e2307653. [PMID: 38039956 DOI: 10.1002/adma.202307653] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 11/16/2023] [Indexed: 12/03/2023]
Abstract
Advances in the development of new biorecognition elements, nanoparticle-based labels as well as instrumentation have inspired the design of new bioaffinity assays. This review critically discusses the potential of nanoparticles to replace current enzymatic or molecular labels in immunoassays and other bioaffinity assays. Successful implementations of nanoparticles in commercial assays and the need for rapid tests incorporating nanoparticles in different roles such as capture support, signal generation elements, and signal amplification systems are highlighted. The limited number of nanoparticles applied in current commercial assays can be explained by challenges associated with the analysis of real samples (e.g., blood, urine, or nasal swabs) that are difficult to resolve, particularly if the same performance can be achieved more easily by conventional labels. Lateral flow assays that are based on the visual detection of the red-colored line formed by colloidal gold are a notable exception, exemplified by SARS-CoV-2 rapid antigen tests that have moved from initial laboratory testing to widespread market adaption in less than two years.
Collapse
Affiliation(s)
- Zdeněk Farka
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
| | - Julian C Brandmeier
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Universitätsstr. 31, 93053, Regensburg, Germany
| | | | - Matěj Pastucha
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
- TestLine Clinical Diagnostics, Křižíkova 188, Brno, 612 00, Czech Republic
| | - Karel Lacina
- CEITEC-Central European Institute of Technology, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
| | - Petr Skládal
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
| | - Tero Soukka
- Department of Life Technologies/Biotechnology, University of Turku, Kiinamyllynkatu 10, Turku, 20520, Finland
| | - Hans H Gorris
- Department of Biochemistry, Faculty of Science, Masaryk University, Kamenice 5, Brno, 625 00, Czech Republic
| |
Collapse
|
10
|
Wei H, Mao J, Sun D, Zhang Q, Cheng L, Yang X, Li P. Strategies to control mycotoxins and toxigenic fungi contamination by nano-semiconductor in food and agro-food: a review. Crit Rev Food Sci Nutr 2023; 63:12488-12512. [PMID: 35880423 DOI: 10.1080/10408398.2022.2102579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
Abstract
Mycotoxins are toxic secondary metabolites generated from toxigenic fungi in the contaminated food and agro-food, which have been regarded as a serious threat to the food safety and human health. Therefore, the control of mycotoxins and toxigenic fungi contamination is of great significance and has attracted the increasing attention of researchers. As we know, nano-semiconductors have many unique properties such as large surface area, structural stability, good biocompatibility, excellent photoelectrical properties, and low cost, which have been developed and applied in many research fields. Recently, nano-semiconductors have also been promisingly applied in mitigating or controlling mycotoxins and toxigenic fungi contaminations in food and agro-food. In this review, the type, occurrence, and toxicity of main mycotoxins in food and agro-food were introduced. Then, a variety of strategies to mitigate the mycotoxin contamination based on nano-semiconductors involving mycotoxins detection, inhibition of toxigenic fungi, and mycotoxins degradation were summarized. Finally, the outlook, opportunities, and challenges have prospected in the future for the mitigation of mycotoxins and toxigenic fungi based on nano-semiconductors.
Collapse
Affiliation(s)
- Hailian Wei
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
| | - Jin Mao
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
- National Reference Laboratory for Agricultural Testing P.R. China, Key Laboratory of Detection for Mycotoxins, Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Hubei Hongshan Laboratory, Wuhan, China
| | - Di Sun
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
| | - Qi Zhang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
- National Reference Laboratory for Agricultural Testing P.R. China, Key Laboratory of Detection for Mycotoxins, Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Hubei Hongshan Laboratory, Wuhan, China
| | - Ling Cheng
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
- National Reference Laboratory for Agricultural Testing P.R. China, Key Laboratory of Detection for Mycotoxins, Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Hubei Hongshan Laboratory, Wuhan, China
| | - Xianglong Yang
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
- National Reference Laboratory for Agricultural Testing P.R. China, Key Laboratory of Detection for Mycotoxins, Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Hubei Hongshan Laboratory, Wuhan, China
| | - Peiwu Li
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan, China
- National Reference Laboratory for Agricultural Testing P.R. China, Key Laboratory of Detection for Mycotoxins, Laboratory of Quality & Safety Risk Assessment for Oilseed Products (Wuhan), Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture, Hubei Hongshan Laboratory, Wuhan, China
| |
Collapse
|
11
|
Ullah I, Nasir A, Kashif M, Sikandar A, Sajid M, Adil M, Rehman AU, Iqbal MU, Ullah H. Incidence of aflatoxin M 1 in cows' milk in Pakistan, effects on milk quality and evaluation of therapeutic management in dairy animals. VET MED-CZECH 2023; 68:238-245. [PMID: 37982002 PMCID: PMC10581521 DOI: 10.17221/18/2023-vetmed] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Accepted: 06/01/2023] [Indexed: 11/21/2023] Open
Abstract
The present study was aimed at measuring the concentration of aflatoxin M1 (AFM1) in the milk of Holstein Friesian cows, its effect on the milk quality and seasonal trends, as well as to investigate the efficacy of a commercial clay-based toxin binder. For this purpose, milk samples from dairy cows (n = 72) were collected and assayed for AFM1 before employing a clay-based toxin binder. The milk samples (n = 72) were collected from selected animals, revealing that 69.4% of the milk samples had AFM1 levels above the United States permissible limit (0.5 μg/kg). The incidence of AFM1 in milk during the winter and summer was 82.5% and 53.1%, respectively. Owing to the presence of AFM1, the level of milk fat, solids-not-fat, and protein were found to be low. Subsequently, the affected animals were divided into two groups, i.e., AFM1 positive control (n = 10) and the experimental group (n = 40). The experimental group of animals were fed the clay-based toxin binder at 25 g/animal/day. A progressive decrease of 19.8% in the AFM1 levels was observed on day 4 and on day 7 (53.6%) in the treatment group. Furthermore, the fat, solids-non-fat and protein increased significantly in the milk. In conclusion, a high level of AFM1 contamination occurs in the milk in Pakistan, affecting the quality of the milk production. Clay-based toxin binders may be used to ensure the milk quality and to protect the animal and consumer health.
Collapse
Affiliation(s)
- Inayat Ullah
- Department of Clinical Sciences, Sub-Campus Jhang, University of Veterinary and Animal Sciences (UVAS), Lahore, Pakistan
| | - Amar Nasir
- Department of Clinical Sciences, Sub-Campus Jhang, University of Veterinary and Animal Sciences (UVAS), Lahore, Pakistan
| | - Muhammad Kashif
- Department of Clinical Sciences, Sub-Campus Jhang, University of Veterinary and Animal Sciences (UVAS), Lahore, Pakistan
| | - Arbab Sikandar
- Department of Basic Sciences, Sub-Campus Jhang UVAS, Lahore, Pakistan
| | - Muhammad Sajid
- Department of Pathobiology, Sub-Campus Jhang UVAS, Lahore, Pakistan
| | - Muhammad Adil
- Department of Basic Sciences, Sub-Campus Jhang UVAS, Lahore, Pakistan
| | - Aziz ur Rehman
- Department of Pathobiology, Sub-Campus Jhang UVAS, Lahore, Pakistan
| | | | - Habib Ullah
- Faculty of Veterinary and Animal Sciences, Gomal University, D. I. Khan, Pakistan
| |
Collapse
|
12
|
Verma AK, Noumani A, Yadav AK, Solanki PR. FRET Based Biosensor: Principle Applications Recent Advances and Challenges. Diagnostics (Basel) 2023; 13:diagnostics13081375. [PMID: 37189476 DOI: 10.3390/diagnostics13081375] [Citation(s) in RCA: 57] [Impact Index Per Article: 28.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2023] [Revised: 03/17/2023] [Accepted: 03/23/2023] [Indexed: 05/17/2023] Open
Abstract
Förster resonance energy transfer (FRET)-based biosensors are being fabricated for specific detection of biomolecules or changes in the microenvironment. FRET is a non-radiative transfer of energy from an excited donor fluorophore molecule to a nearby acceptor fluorophore molecule. In a FRET-based biosensor, the donor and acceptor molecules are typically fluorescent proteins or fluorescent nanomaterials such as quantum dots (QDs) or small molecules that are engineered to be in close proximity to each other. When the biomolecule of interest is present, it can cause a change in the distance between the donor and acceptor, leading to a change in the efficiency of FRET and a corresponding change in the fluorescence intensity of the acceptor. This change in fluorescence can be used to detect and quantify the biomolecule of interest. FRET-based biosensors have a wide range of applications, including in the fields of biochemistry, cell biology, and drug discovery. This review article provides a substantial approach on the FRET-based biosensor, principle, applications such as point-of-need diagnosis, wearable, single molecular FRET (smFRET), hard water, ions, pH, tissue-based sensors, immunosensors, and aptasensor. Recent advances such as artificial intelligence (AI) and Internet of Things (IoT) are used for this type of sensor and challenges.
Collapse
Affiliation(s)
- Awadhesh Kumar Verma
- Lab D NanoBiolab, Special Centre for Nanoscience, Jawaharlal Nehru University, New Delhi 110067, India
| | - Ashab Noumani
- Lab D NanoBiolab, Special Centre for Nanoscience, Jawaharlal Nehru University, New Delhi 110067, India
| | - Amit K Yadav
- Lab D NanoBiolab, Special Centre for Nanoscience, Jawaharlal Nehru University, New Delhi 110067, India
| | - Pratima R Solanki
- Lab D NanoBiolab, Special Centre for Nanoscience, Jawaharlal Nehru University, New Delhi 110067, India
| |
Collapse
|
13
|
Detection of wheat toxigenic Aspergillus flavus based on nano-composite colorimetric sensing technology. Food Chem 2023; 405:134803. [DOI: 10.1016/j.foodchem.2022.134803] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/03/2022] [Revised: 10/26/2022] [Accepted: 10/27/2022] [Indexed: 11/11/2022]
|
14
|
Wang X, Liu W, Zuo H, Shen W, Zhang Y, Liu R, Geng L, Wang W, Shao C, Sun T. Development of a magnetic separation immunoassay with high sensitivity and time-saving for detecting aflatoxin B1 in agricultural crops using nanobody. Eur Food Res Technol 2023. [DOI: 10.1007/s00217-023-04202-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
|
15
|
Dadmehr M, Shahi SC, Malekkiani M, Korouzhdehi B, Tavassoli A. A stem-loop like aptasensor for sensitive detection of aflatoxin based on graphene oxide/AuNPs nanocomposite platform. Food Chem 2023; 402:134212. [DOI: 10.1016/j.foodchem.2022.134212] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 08/27/2022] [Accepted: 09/09/2022] [Indexed: 01/10/2023]
|
16
|
Recent Progress and Challenges on the Microfluidic Assay of Pathogenic Bacteria Using Biosensor Technology. Biomimetics (Basel) 2022; 7:biomimetics7040175. [PMID: 36412703 PMCID: PMC9680295 DOI: 10.3390/biomimetics7040175] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 10/16/2022] [Accepted: 10/24/2022] [Indexed: 12/14/2022] Open
Abstract
Microfluidic technology is one of the new technologies that has been able to take advantage of the specific properties of micro and nanoliters, and by reducing the costs and duration of tests, it has been widely used in research and treatment in biology and medicine. Different materials are often processed into miniaturized chips containing channels and chambers within the microscale range. This review (containing 117 references) demonstrates the significance and application of nanofluidic biosensing of various pathogenic bacteria. The microfluidic application devices integrated with bioreceptors and advanced nanomaterials, including hyperbranched nano-polymers, carbon-based nanomaterials, hydrogels, and noble metal, was also investigated. In the present review, microfluid methods for the sensitive and selective recognition of photogenic bacteria in various biological matrices are surveyed. Further, the advantages and limitations of recognition methods on the performance and efficiency of microfluidic-based biosensing of photogenic bacteria are critically investigated. Finally, the future perspectives, research opportunities, potential, and prospects on the diagnosis of disease related to pathogenic bacteria based on microfluidic analysis of photogenic bacteria are provided.
Collapse
|
17
|
Ndiaye S, Zhang M, Fall M, Ayessou NM, Zhang Q, Li P. Current Review of Mycotoxin Biodegradation and Bioadsorption: Microorganisms, Mechanisms, and Main Important Applications. Toxins (Basel) 2022; 14:729. [PMID: 36355979 PMCID: PMC9694041 DOI: 10.3390/toxins14110729] [Citation(s) in RCA: 20] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2022] [Revised: 09/08/2022] [Accepted: 09/28/2022] [Indexed: 01/26/2023] Open
Abstract
Mycotoxins are secondary metabolites produced by fungi. Food/feed contamination by mycotoxins is a great threat to food safety. The contamination can occur along the food chain and can cause many diseases in humans and animals, and it also can cause economic losses. Many detoxification methods, including physical, chemical, and biological techniques, have been established to eliminate mycotoxins in food/feed. The biological method, with mycotoxin detoxification by microorganisms, is reliable, efficient, less costly, and easy to use compared with physical and chemical ones. However, it is important to discover the metabolite's toxicity resulting from mycotoxin biodegradation. These compounds can be less or more toxic than the parent. On the other hand, mechanisms involved in a mycotoxin's biological control remain still unclear. Mostly, there is little information about the method used by microorganisms to control mycotoxins. Therefore, this article presents an overview of the most toxic mycotoxins and the different microorganisms that have a mycotoxin detoxification ability. At the same time, different screening methods for degradation compound elucidation are given. In addition, the review summarizes mechanisms of mycotoxin biodegradation and gives some applications.
Collapse
Affiliation(s)
- Seyni Ndiaye
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture and Rural Affairs, Wuhan 430062, China
- Laboratoire D’Analyses et D’Essai, Ecole Supérieure Polytechnique, Université Cheikh Anta Diop, Fann-Dakar 5085, Senegal
| | - Minhui Zhang
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture and Rural Affairs, Wuhan 430062, China
| | - Mouhamed Fall
- Key Laboratory of Agro-Products Processing, Institute of Agro-Products Processing Science and Technology, Chinese Academy of Agricultural Sciences, Ministry of Agriculture, Beijing 100193, China
| | - Nicolas M. Ayessou
- Laboratoire D’Analyses et D’Essai, Ecole Supérieure Polytechnique, Université Cheikh Anta Diop, Fann-Dakar 5085, Senegal
| | - Qi Zhang
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture and Rural Affairs, Wuhan 430062, China
- Hubei Hongshan Laboratory, Wuhan 430070, China
| | - Peiwu Li
- Key Laboratory of Biology and Genetic Improvement of Oil Crops, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China
- Oil Crops Research Institute, Chinese Academy of Agricultural Sciences, Wuhan 430062, China
- Key Laboratory of Detection for Mycotoxins, Ministry of Agriculture and Rural Affairs, Wuhan 430062, China
- Laboratory of Risk Assessment for Oilseeds Products (Wuhan), Ministry of Agriculture and Rural Affairs, Wuhan 430062, China
- Hubei Hongshan Laboratory, Wuhan 430070, China
| |
Collapse
|
18
|
Yue Q, Li X, Fang J, Li M, Zhang J, Zhao G, Cao W, Wei Q. Oxygen Free Radical Scavenger PtPd@PDA as a Dual-Mode Quencher of Electrochemiluminescence Immunosensor for the Detection of AFB1. Anal Chem 2022; 94:11476-11482. [PMID: 35950288 DOI: 10.1021/acs.analchem.2c00788] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Here, a dual-mode quenched electrochemiluminescence (ECL) immunosensor based on PtPd@PDA was proposed. Among them, nitrogen-doped hydrazide conjugated carbon dots (NHCDs), as an ECL emitter and a donor of resonance energy transfer, were quenched by PtPd@PDA (receptor). At the same time, PDA in PtPd@PDA, as an oxygen radical scavenger, completed the further quenching of the ECL signal by consuming O2•- generated by the decomposition of co-reactant H2O2. The dual-mode quenching from the above two channels was achieved. In addition, compared with the traditional carbon quantum dots, NHCDs as ECL emitters had lower excitation potential. Moreover, a large number of amino groups provided by aminated MWCNTs could capture more antibodies while connecting with NHCDs. Under the optimum experimental conditions, taking aflatoxin B1 as the target, the proposed sensor with good specificity, stability, and reproducibility had good linearity when the concentration of AFB1 was 0.01-100 ng/mL, with the detection limit of 2.63 pg/mL (S/N = 3). This strategy provided more possibilities for the application of dopamine metal nanocomposites in electrochemiluminescence analysis and offered a new approach to detect AFB1.
Collapse
Affiliation(s)
- Qi Yue
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Xuan Li
- Qingdao Bright Moon Seaweed Group Co., Ltd., Qingdao 266000, P. R. China
| | - Jinglong Fang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Min Li
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Jingjing Zhang
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Guanhui Zhao
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Wei Cao
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| | - Qin Wei
- Key Laboratory of Interfacial Reaction & Sensing Analysis in Universities of Shandong, School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, P. R. China
| |
Collapse
|
19
|
He F, Lv X, Li X, Yao M, Li K, Deng Y. Fluorescent microspheres lateral flow assay integrated with Smartphone-based reader for multiple microRNAs detection. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107551] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
20
|
Synthesis of Metal–Organic Frameworks Quantum Dots Composites as Sensors for Endocrine-Disrupting Chemicals. Int J Mol Sci 2022; 23:ijms23147980. [PMID: 35887328 PMCID: PMC9324456 DOI: 10.3390/ijms23147980] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2022] [Revised: 07/10/2022] [Accepted: 07/12/2022] [Indexed: 11/17/2022] Open
Abstract
Hazardous chemical compounds such as endocrine-disrupting chemicals (EDCs) are widespread and part of the materials we use daily. Among these compounds, bisphenol A (BPA) is the most common endocrine-disrupting chemical and is prevalent due to the chemical raw materials used to manufacture thermoplastic polymers, rigid foams, and industrial coatings. General exposure to endocrine-disrupting chemicals constitutes a serious health hazard, especially to reproductive systems, and can lead to transgenerational diseases in adults due to exposure to these chemicals over several years. Thus, it is necessary to develop sensors for early detection of endocrine-disrupting chemicals. In recent years, the use of metal–organic frameworks (MOFs) as sensors for EDCs has been explored due to their distinctive characteristics, such as wide surface area, outstanding chemical fastness, structural tuneability, gas storage, molecular separation, proton conductivity, and catalyst activity, among others which can be modified to sense hazardous environmental pollutants such as EDCs. In order to improve the versatility of MOFs as sensors, semiconductor quantum dots have been introduced into the MOF pores to form metal–organic frameworks/quantum dots composites. These composites possess a large optical absorption coefficient, low toxicity, direct bandgap, formidable sensing capacity, high resistance to change under light and tunable visual qualities by varying the size and compositions, which make them useful for applications as sensors for probing of dangerous and risky environmental contaminants such as EDCs and more. In this review, we explore various synthetic strategies of (MOFs), quantum dots (QDs), and metal–organic framework quantum dots composites (MOFs@QDs) as efficient compounds for the sensing of ecological pollutants, contaminants, and toxicants such as EDCs. We also summarize various compounds or materials used in the detection of BPA as well as the sensing ability and capability of MOFs, QDs, and MOFs@QDs composites that can be used as sensors for EDCs and BPA.
Collapse
|
21
|
Adunphatcharaphon S, Elliott CT, Sooksimuang T, Charlermroj R, Petchkongkaew A, Karoonuthaisiri N. The evolution of multiplex detection of mycotoxins using immunoassay platform technologies. JOURNAL OF HAZARDOUS MATERIALS 2022; 432:128706. [PMID: 35339833 DOI: 10.1016/j.jhazmat.2022.128706] [Citation(s) in RCA: 47] [Impact Index Per Article: 15.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/30/2021] [Revised: 02/24/2022] [Accepted: 03/12/2022] [Indexed: 06/14/2023]
Abstract
Mycotoxins present serious threats not only for public health, but also for the economy and environment. The problems become more complex and serious due to co-contamination of multiple hazardous mycotoxins in commodities and environment. To mitigate against this issue, accurate, affordable, and rapid multiplex detection methods are required. This review presents an overview of emerging rapid immuno-based multiplex methods capable of detecting mycotoxins present in agricultural products and feed ingredients published within the past five years. The scientific principles, advantages, disadvantages, and assay performance of these rapid multiplex immunoassays, including lateral flow, fluorescence polarization, chemiluminescence, surface plasmon resonance, surface enhanced Raman scattering, electrochemical sensor, and nanoarray are discussed. From the recent literature landscape, it is predicted that the future trend of the detection methods for multiple mycotoxins will rely on the advance of various sensor technologies, a variety of enhancing and reporting signals based on nanomaterials, rapid and effective sample preparation, and capacity for quantitative analysis.
Collapse
Affiliation(s)
- Saowalak Adunphatcharaphon
- School of Food Science and Technology, Faculty of Science and Technology, Thammasat University, 99 Mhu 18, Pahonyothin Road, Khong Luang, Pathum Thani 12120, Thailand; International Joint Research Center on Food Security, 113 Thailand Science Park, Phahonyothin Road, Khong Luang, Pathum Thani 12120, Thailand.
| | - Christopher T Elliott
- International Joint Research Center on Food Security, 113 Thailand Science Park, Phahonyothin Road, Khong Luang, Pathum Thani 12120, Thailand; Institute for Global Food Security, Queen's University, Belfast, Biological Sciences Building, 19 Chlorine Gardens, Belfast BT9 5DL, United Kingdom.
| | - Thanasat Sooksimuang
- International Joint Research Center on Food Security, 113 Thailand Science Park, Phahonyothin Road, Khong Luang, Pathum Thani 12120, Thailand; National Metal and Materials Technology Center (MTEC), National Science and Technology Development Agency (NSTDA), 114 Thailand Science Park, Phahonyothin Road, Khong Luang, Pathum Thani 12120, Thailand.
| | - Ratthaphol Charlermroj
- International Joint Research Center on Food Security, 113 Thailand Science Park, Phahonyothin Road, Khong Luang, Pathum Thani 12120, Thailand; National Center for Genetic Engineering and Biotechnology (BIOTEC), National Science and Technology Development Agency (NSTDA), 113 Thailand Science Park, Phahonyothin Road, Khong Luang, Pathum Thani 12120, Thailand.
| | - Awanwee Petchkongkaew
- School of Food Science and Technology, Faculty of Science and Technology, Thammasat University, 99 Mhu 18, Pahonyothin Road, Khong Luang, Pathum Thani 12120, Thailand; International Joint Research Center on Food Security, 113 Thailand Science Park, Phahonyothin Road, Khong Luang, Pathum Thani 12120, Thailand; Institute for Global Food Security, Queen's University, Belfast, Biological Sciences Building, 19 Chlorine Gardens, Belfast BT9 5DL, United Kingdom.
| | - Nitsara Karoonuthaisiri
- International Joint Research Center on Food Security, 113 Thailand Science Park, Phahonyothin Road, Khong Luang, Pathum Thani 12120, Thailand; Institute for Global Food Security, Queen's University, Belfast, Biological Sciences Building, 19 Chlorine Gardens, Belfast BT9 5DL, United Kingdom; National Center for Genetic Engineering and Biotechnology (BIOTEC), National Science and Technology Development Agency (NSTDA), 113 Thailand Science Park, Phahonyothin Road, Khong Luang, Pathum Thani 12120, Thailand.
| |
Collapse
|
22
|
Peltomaa R, Abbas A, Yli-Mattila T, Lamminmäki U. Single-step noncompetitive immunocomplex immunoassay for rapid aflatoxin detection. Food Chem 2022; 392:133287. [PMID: 35636188 DOI: 10.1016/j.foodchem.2022.133287] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 05/06/2022] [Accepted: 05/20/2022] [Indexed: 11/24/2022]
Abstract
Owing to the high carcinogenicity of aflatoxins, these toxic secondary metabolites pose a severe risk to human and animal health and can have major economic implications. Herein, we report the development of a noncompetitive immunoassay for aflatoxins based on a monoclonal capture antibody and a unique anti-immunocomplex (anti-IC) antibody fragment (scFv) isolated from a synthetic antibody repertoire. The anti-IC scFv recognizes the immunocomplex and enables the development of noncompetitive sandwich-type assays despite the small size of the analyte. The single-step assay developed in this work, with a detection limit of 70 pg mL-1, could detect aflatoxins within 15 min. The assay was applied to the analysis of spiked food samples, and the results showed that the method could provide a rapid and simple tool for aflatoxin detection. Moreover, the work demonstrates the potential of anti-IC antibodies and non-competitive immunoassays for the analysis of small molecule contaminants.
Collapse
Affiliation(s)
- Riikka Peltomaa
- Department of Life Technologies, University of Turku, Kiinamyllynkatu 10, 20520 Turku, Finland; Turku Collegium for Science, Medicine and Technology (TCSMT), University of Turku, Finland.
| | - Asmaa Abbas
- Department of Life Technologies, University of Turku, Kiinamyllynkatu 10, 20520 Turku, Finland
| | - Tapani Yli-Mattila
- Department of Life Technologies, University of Turku, Kiinamyllynkatu 10, 20520 Turku, Finland
| | - Urpo Lamminmäki
- Department of Life Technologies, University of Turku, Kiinamyllynkatu 10, 20520 Turku, Finland
| |
Collapse
|
23
|
Gao L, Li Y, Huang ZZ, Tan H. Integrated enzyme with stimuli-responsive coordination polymer for personal glucose meter-based portable immunoassay. Anal Chim Acta 2022; 1207:339774. [DOI: 10.1016/j.aca.2022.339774] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2022] [Revised: 03/22/2022] [Accepted: 03/24/2022] [Indexed: 11/01/2022]
|
24
|
Drozd DD, Byzova NA, Pidenko PS, Tsyupka DV, Strokin PD, Goryacheva OA, Zherdev AV, Goryacheva IY, Dzantiev BB. Luminescent alloyed quantum dots for turn-off enzyme-based assay. Anal Bioanal Chem 2022; 414:4471-4480. [PMID: 35359179 DOI: 10.1007/s00216-022-04016-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2022] [Accepted: 03/11/2022] [Indexed: 11/01/2022]
Abstract
A new bioanalytical labeling system based on alloyed quantum dots' (QDs) photoluminescence quenching caused by an enzymatic reaction has been developed and tested for the first time. The catalytic role of the enzyme provides high sensitivity and the possibility of varying detecting time to improve assay sensitivity. Alloyed luminescent QDs were chosen in view of their small size (5-7 nm) and the high sensitivity of their optical properties to physicochemical interactions. Here, we described the synthesis of alloyed luminescent QDs and demonstrated the possibility of using them as a luminescent turn-off substrate for enzymatic assay. Synthesized alloyed QDs were found to be a sensitive turn-off substrate for glucose oxidase in homogeneous and heterogeneous assay models. CdZnSeS and CdZnSeS/ZnS QDs covered with dihydrolipoic acid and 2-mercaptoethanol were tested. A glucose oxidase limit of detection of 6.6 nM for the heterogenous high-throughput model assay was reached.
Collapse
Affiliation(s)
- Daniil D Drozd
- Institute of Chemistry, Saratov State University, Astrakhanskaya 83, 410012, Saratov, Russia.
| | - Nadezhda A Byzova
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky prospect 33, 119071, Moscow, Russia
| | - Pavel S Pidenko
- Institute of Chemistry, Saratov State University, Astrakhanskaya 83, 410012, Saratov, Russia
| | - Daria V Tsyupka
- Institute of Chemistry, Saratov State University, Astrakhanskaya 83, 410012, Saratov, Russia
| | - Pavel D Strokin
- Institute of Chemistry, Saratov State University, Astrakhanskaya 83, 410012, Saratov, Russia
| | - Olga A Goryacheva
- Institute of Chemistry, Saratov State University, Astrakhanskaya 83, 410012, Saratov, Russia
| | - Anatoly V Zherdev
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky prospect 33, 119071, Moscow, Russia
| | - Irina Yu Goryacheva
- Institute of Chemistry, Saratov State University, Astrakhanskaya 83, 410012, Saratov, Russia
| | - Boris B Dzantiev
- A.N. Bach Institute of Biochemistry, Research Center of Biotechnology of the Russian Academy of Sciences, Leninsky prospect 33, 119071, Moscow, Russia
| |
Collapse
|
25
|
Pérez-Fernández B, Muñiz ADLE. Electrochemical biosensors based on nanomaterials for aflatoxins detection: A review (2015–2021). Anal Chim Acta 2022; 1212:339658. [DOI: 10.1016/j.aca.2022.339658] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2021] [Revised: 02/09/2022] [Accepted: 02/24/2022] [Indexed: 12/25/2022]
|
26
|
Lorenzen AL, dos Santos AM, dos Santos LP, da Silva Pinto L, Conceição FR, Wolfart F. PEDOT-AuNPs-based impedimetric immunosensor for the detection of SARS-CoV-2 antibodies. Electrochim Acta 2022; 404:139757. [PMID: 34955549 PMCID: PMC8684030 DOI: 10.1016/j.electacta.2021.139757] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2021] [Revised: 12/11/2021] [Accepted: 12/16/2021] [Indexed: 12/16/2022]
Abstract
Electrochemical sensors and biosensors are useful techniques for fast, inexpensive, sensitive, and easy detection of innumerous specimen. In face of COVID-19 pandemic, it became evident the necessity of a rapid and accurate diagnostic test, so the impedimetric immunosensor approach can be a good alternative to replace the conventional tests due to the specific antibody-antigen binding interaction and the fast response in comparison to traditional methods. In this work, a modified electrode with electrosynthesized PEDOT and gold nanoparticles followed by the immobilization of truncated nucleoprotein (N aa160-406aa) was used for a fast and reliable detection of antibodies against COVID-19 in human serum sample. The method consists in analyzing the charge-transfer resistance (RCT) variation before and after the modified electrode comes into contact with the positive and negative serum sample for COVID-19, using [Fe(CN)6]3-/4- as a probe. The results show a linear and selective response for serum samples diluted in a range of 2.5 × 103 to 20 × 103. Also, the electrode material was fully characterized by Raman spectroscopy, transmission electron microscopy and scanning electron microscopy coupled with EDS, indicating that the gold nanoparticles were well distributed around the polymer matrix and the presence of the biological sample was confirmed by EDS analysis. EIS measurements allowed to differentiate the negative and positive samples by the difference in the RCT magnitude, proving that the material developed here has potential properties to be applied in impedimetric immunosensors for the detection of SARS-CoV-2 antibodies in about 30 min.
Collapse
Affiliation(s)
- Ana Luiza Lorenzen
- Instituto Federal de Educação, Ciência e Tecnologia Farroupilha – Campus São Borja, Rua Otaviano Castilho Mendes, 355, Betim, São Borja, RS CEP 97670-000, Brazil
| | - Ariane Moraes dos Santos
- Instituto Federal de Educação, Ciência e Tecnologia Farroupilha – Campus São Borja, Rua Otaviano Castilho Mendes, 355, Betim, São Borja, RS CEP 97670-000, Brazil
| | - Luâni Poll dos Santos
- Instituto Federal de Educação, Ciência e Tecnologia Farroupilha – Campus São Borja, Rua Otaviano Castilho Mendes, 355, Betim, São Borja, RS CEP 97670-000, Brazil
| | - Luciano da Silva Pinto
- Universidade Federal de Pelotas, Centro de Desenvolvimento Tecnológico, Núcleo de Biotecnologia – Campus Capão do Leão, S/N, Capão do Leão, RS CEP 96160-000, Brazil
| | - Fabricio Rochedo Conceição
- Universidade Federal de Pelotas, Centro de Desenvolvimento Tecnológico, Núcleo de Biotecnologia – Campus Capão do Leão, S/N, Capão do Leão, RS CEP 96160-000, Brazil
| | - Franciele Wolfart
- Instituto Federal de Educação, Ciência e Tecnologia Farroupilha – Campus São Borja, Rua Otaviano Castilho Mendes, 355, Betim, São Borja, RS CEP 97670-000, Brazil,Corresponding author
| |
Collapse
|
27
|
Wang Y, Zhang C, Wang J, Knopp D. Recent Progress in Rapid Determination of Mycotoxins Based on Emerging Biorecognition Molecules: A Review. Toxins (Basel) 2022; 14:73. [PMID: 35202100 PMCID: PMC8874725 DOI: 10.3390/toxins14020073] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 01/14/2022] [Accepted: 01/15/2022] [Indexed: 12/12/2022] Open
Abstract
Mycotoxins are secondary metabolites produced by fungal species, which pose significant risk to humans and livestock. The mycotoxins which are produced from Aspergillus, Penicillium, and Fusarium are considered most important and therefore regulated in food- and feedstuffs. Analyses are predominantly performed by official laboratory methods in centralized labs by expert technicians. There is an urgent demand for new low-cost, easy-to-use, and portable analytical devices for rapid on-site determination. Most significant advances were realized in the field bioanalytical techniques based on molecular recognition. This review aims to discuss recent progress in the generation of native biomolecules and new bioinspired materials towards mycotoxins for the development of reliable bioreceptor-based analytical methods. After brief presentation of basic knowledge regarding characteristics of most important mycotoxins, the generation, benefits, and limitations of present and emerging biorecognition molecules, such as polyclonal (pAb), monoclonal (mAb), recombinant antibodies (rAb), aptamers, short peptides, and molecularly imprinted polymers (MIPs), are discussed. Hereinafter, the use of binders in different areas of application, including sample preparation, microplate- and tube-based assays, lateral flow devices, and biosensors, is highlighted. Special focus, on a global scale, is placed on commercial availability of single receptor molecules, test-kits, and biosensor platforms using multiplexed bead-based suspension assays and planar biochip arrays. Future outlook is given with special emphasis on new challenges, such as increasing use of rAb based on synthetic and naïve antibody libraries to renounce animal immunization, multiple-analyte test-kits and high-throughput multiplexing, and determination of masked mycotoxins, including stereoisomeric degradation products.
Collapse
Affiliation(s)
- Yanru Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Xianyang 712100, China; (Y.W.); (C.Z.)
| | - Cui Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Xianyang 712100, China; (Y.W.); (C.Z.)
| | - Jianlong Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Xianyang 712100, China; (Y.W.); (C.Z.)
| | - Dietmar Knopp
- Chair for Analytical Chemistry and Water Chemistry, Institute of Hydrochemistry, Technische Universitat München, Elisabeth-Winterhalter-Weg 6, D-81377 München, Germany
| |
Collapse
|
28
|
Enhancing the detection sensitivity of nanobody against aflatoxin B 1 through structure-guided modification. Int J Biol Macromol 2022; 194:188-197. [PMID: 34863829 DOI: 10.1016/j.ijbiomac.2021.11.182] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Revised: 11/25/2021] [Accepted: 11/26/2021] [Indexed: 11/24/2022]
Abstract
Nanobodies (Nbs) have shown great potential in immunodetection of small-molecule contaminants in food and environmental monitoring. However, the limited knowledge of the mechanism of Nbs binding to small molecules has hampered the development of high-affinity Nbs and assay improvement. We previously reported two homologous nanobodies Nb26 and Nb28 specific to aflatoxin B1 (AFB1), with the former exhibiting higher sensitivity in ELISA. Herein, Nb26 was selected as the model antibody to resolve its solution nuclear magnetic resonance (NMR) structure, and investigate its AFB1 recognition mechanism. The results revealed that Nb26 exhibits a typical immunoglobulin fold and its AFB1-binding interface is uniquely located in complementarity-determining region 3 (CDR3) and framework region 2 (FR2). This finding was applied to improve the binding activity of Nb28 against AFB1 by constructing two Nb28-based mutants A50V and S102D, resulting in 2.3- and 3.3-fold sensitivity enhancement over the wild type, respectively. This study develops an NMR-based strategy to analyze the underlying mechanism of Nb against AFB1, and successfully generated two site-modified Nbs with improved detection sensitivity. It is believed that this work could greatly expand the applications of Nbs by providing a way to enhance the binding activity.
Collapse
|
29
|
Hui Y, Peng H, Zhang F, Zhang L, Yufang L, Zhao A, Jia R, Wang B, Song Y. A novel electrochemical aptasensor based on layer-by-layer assembly of DNA-Au@Ag conjugates for rapid detection of aflatoxin M 1 in milk samples. J Dairy Sci 2021; 105:1966-1977. [PMID: 34955267 DOI: 10.3168/jds.2021-20931] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2021] [Accepted: 11/12/2021] [Indexed: 01/10/2023]
Abstract
Aflatoxin M1 (AFM1) is a common toxin in dairy products that causes acute and chronic human health disorders. Thus, the development of a rapid and accurate AFM1 detection method is of vital importance for food safety monitoring. This work was to develop a novel electrochemical aptasensor for sensitive and specific determination of AFM1. The dendritic-like nanostructure was formed on the gold electrode surface by layer-by-layer assembly of gold-silver core-shell nanoparticles modified with DNA conjugates. In the presence of AFM1, the specific recognition between AFM1 and Apt caused the disassociation of the DNA controlled dual Au@Ag conjugates from the surface of the electrode, causing less methylene blue to bind to the surface and weakening the electrochemical signal. The more AFM1 there is, the weaker the electrochemical signal. Transmission electron microscope results showed that the successfully synthesized Au@Ag nanoparticles exhibited a core-shell structure with Au as core and Ag as shell, and their average diameter was about 30 nm. Under optimal conditions, the electrochemical aptasensor showed a wide detection ranging from 0.05 ng mL-1 to 200 ng mL-1, and a low detection limit of 0.02 ng mL-1. Moreover, the proposed strategy has been successfully applied to the detection of AFM1 in cow, goat, and sheep milk samples with satisfactory recoveries ranging from 91.10% to 104.05%. This work can provide a novel rapid detection method for AFM1, and also provide a new sensing platform for the detection of other toxins.
Collapse
Affiliation(s)
- Yuanyuan Hui
- College of Food Engineering and Nutritional Science, Shaanxi Normal University, Xi'an, Shaanxi 710119, China
| | - Haishuai Peng
- College of Food Engineering and Nutritional Science, Shaanxi Normal University, Xi'an, Shaanxi 710119, China
| | - Fuxin Zhang
- College of Food Engineering and Nutritional Science, Shaanxi Normal University, Xi'an, Shaanxi 710119, China
| | - Lei Zhang
- College of Animal Science and Technology, Northwest A&F University, Yangling 712100, China
| | - Liu Yufang
- College of Food Engineering and Nutritional Science, Shaanxi Normal University, Xi'an, Shaanxi 710119, China
| | - Aiqing Zhao
- College of Food Engineering and Nutritional Science, Shaanxi Normal University, Xi'an, Shaanxi 710119, China
| | - Rong Jia
- College of Food Engineering and Nutritional Science, Shaanxi Normal University, Xi'an, Shaanxi 710119, China
| | - Bini Wang
- College of Food Engineering and Nutritional Science, Shaanxi Normal University, Xi'an, Shaanxi 710119, China; Shaanxi Provincial Key Laboratory of Electroanalytical Chemistry, Northwest University, Xi'an, Shaanxi 710069, China.
| | - Yuxuan Song
- College of Animal Science and Technology, Northwest A&F University, Yangling 712100, China.
| |
Collapse
|
30
|
Yan T, Zhu J, Li Y, He T, Yang Y, Liu M. Development of a biotinylated nanobody for sensitive detection of aflatoxin B 1 in cereal via ELISA. Talanta 2021; 239:123125. [PMID: 34920257 DOI: 10.1016/j.talanta.2021.123125] [Citation(s) in RCA: 30] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2021] [Revised: 11/29/2021] [Accepted: 12/01/2021] [Indexed: 01/23/2023]
Abstract
Aflatoxin B1 (AFB1) contamination is a severe threat to food safety and human health, and requires continuous monitoring. In this study, we developed a biotin-streptavidin-amplified enzyme-linked immunosorbent assay (BA-ELISA) by using biotinylated nanobody Nb26 and streptavidin-conjugated polymerized horseradish peroxide (SA-PolyHRP) for sensitive and rapid detection of AFB1 in cereal. Under the optimal condition, the IC50 value of the BA-ELISA was improved to 0.21 ng mL-1 for AFB1, satisfying the requirement of detection limit in practical applications. The total assay time of our strategy is reduced to 50 min from 2 h in conventional competitive ELISA. Additionally, the BA-ELISA saves as much as 98% of the antibody in comparison to the previous classic ELISA. Our work also demonstrated an interesting phenomenon that the biotinylated Nb26 achieved better selectivity to AFB1, which could possibly result from the steric hindrance that interferes reaction between the Nb26 and the AFB1 analogs. Furthermore, the assay was used to detect AFB1 in two cereal samples, and the results were in good agreement with that obtained by high performance liquid chromatography. The developed BA-ELISA can be used for routine screening analysis of AFB1, and offers a promising strategy for measuring low concentrations of food contaminants.
Collapse
Affiliation(s)
- Tingting Yan
- State Key Laboratory of Magnetic Resonance and Atomic Molecular Physics, Key Laboratory of Magnetic Resonance in Biological Systems, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences - Wuhan National Laboratory for Optoelectronics, Hubei Optics Valley Laboratory, Wuhan, 430071, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Jiang Zhu
- State Key Laboratory of Magnetic Resonance and Atomic Molecular Physics, Key Laboratory of Magnetic Resonance in Biological Systems, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences - Wuhan National Laboratory for Optoelectronics, Hubei Optics Valley Laboratory, Wuhan, 430071, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Ying Li
- State Key Laboratory of Magnetic Resonance and Atomic Molecular Physics, Key Laboratory of Magnetic Resonance in Biological Systems, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences - Wuhan National Laboratory for Optoelectronics, Hubei Optics Valley Laboratory, Wuhan, 430071, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| | - Ting He
- State Key Laboratory of Magnetic Resonance and Atomic Molecular Physics, Key Laboratory of Magnetic Resonance in Biological Systems, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences - Wuhan National Laboratory for Optoelectronics, Hubei Optics Valley Laboratory, Wuhan, 430071, China.
| | - Yunhuang Yang
- State Key Laboratory of Magnetic Resonance and Atomic Molecular Physics, Key Laboratory of Magnetic Resonance in Biological Systems, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences - Wuhan National Laboratory for Optoelectronics, Hubei Optics Valley Laboratory, Wuhan, 430071, China; University of Chinese Academy of Sciences, Beijing, 100049, China.
| | - Maili Liu
- State Key Laboratory of Magnetic Resonance and Atomic Molecular Physics, Key Laboratory of Magnetic Resonance in Biological Systems, National Center for Magnetic Resonance in Wuhan, Wuhan Institute of Physics and Mathematics, Innovation Academy for Precision Measurement Science and Technology, Chinese Academy of Sciences - Wuhan National Laboratory for Optoelectronics, Hubei Optics Valley Laboratory, Wuhan, 430071, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| |
Collapse
|
31
|
Comparative Study of Four Coloured Nanoparticle Labels in Lateral Flow Immunoassay. NANOMATERIALS 2021; 11:nano11123277. [PMID: 34947626 PMCID: PMC8708713 DOI: 10.3390/nano11123277] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 11/26/2021] [Accepted: 11/29/2021] [Indexed: 02/07/2023]
Abstract
The detection limit of lateral flow immunoassay (LFIA) is largely determined by the properties of the label used. We compared four nanoparticle labels differing in their chemical composition and colour: (1) gold nanoparticles (Au NPs), red; (2) Au-core/Pt-shell nanoparticles (Au@Pt NPs), black; (3) latex nanoparticles (LPs), green; and (4) magnetic nanoparticles (MPs), brown. The comparison was carried out using one target analyte—Erwinia amylovora, the causal bacterial agent of fire blight. All nanoparticles were conjugated with antibodies through methods that provide maximum functional coverage like physical adsorption (Au NPs, Au@Pt NPs) and covalent bonding (LPs, MPs). All conjugates demonstrated the same ability to bind with E. amylovora through enzyme-linked immunosorbent assay where optical properties of the nanoparticles do not determine the registered signal. However, half-maximal binding was achieved at different numbers of nanoparticles because they differ in size. All conjugates based on four nanoparticle labels were used for lateral flow assays. As a result, Au@Pt NPs provided the minimal detection limit that corresponded to 103 CFU/mL. Au NPs and LPs detected 104 CFU/mL, and MPs detected 105 CFU/mL. The results highlight that simply choosing a coloured label can significantly affect the detection limit of LFIA.
Collapse
|
32
|
Zhang X, Liao X, Wu Y, Xiong W, Du J, Tu Z, Yang W, Wang D. A sensitive electrochemical immunosensing interface for label-free detection of aflatoxin B 1 by attachment of nanobody to MWCNTs-COOH@black phosphorene. Anal Bioanal Chem 2021; 414:1129-1139. [PMID: 34719746 DOI: 10.1007/s00216-021-03738-1] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2021] [Revised: 10/01/2021] [Accepted: 10/15/2021] [Indexed: 11/26/2022]
Abstract
A label-free electrochemical immunosensor has advantages of real-time and rapid detection, but it is weak in detection of small molecular toxins such as aflatoxin B1 (AFB1). The greatest obstacle to achieving this is that small molecules bound to a common immunosensing interface cannot interfere with electron transfer effectively and the detection signal is so weak. Therefore, a sensitive electrochemical immunosensing interface for small molecules is urgently needed. Here, we employed functionalized black phosphorene (BP) as electrode modification materials and anti-AFB1 nanobody (Nb) as a biorecognition element to construct a very sensitive immunosensing interface towards small molecular AFB1. The BP functionalized by carboxylic multi-walled carbon nanotubes (MWCNTs-COOH) via P-C bonding behaved with a satisfactory stability and good catalytic performance for the ferricyanide/ferrocyanide probe, while the small-sized Nb showed good compatibility with the functionalized BP and also had less influence on electron transfer than monoclonal antibody (mAb). Expectedly, the as-prepared immunosensing interface was very sensitive to AFB1 detection by differential pulse voltammetry (DPV) in a redox probe system. Under optimized conditions, a linear range from 1.0 pM to 5.0 nM and an ultralow detection limit of 0.27 pM were obtained. Additionally, the fabricated immunosensor exhibited satisfactory stability, specificity, and reproducibility. The strategy proposed here provides a more reliable reference for label-free sensing of small molecules in food samples.
Collapse
Affiliation(s)
- Xue Zhang
- Research Center of Mycotoxin, Jiangxi Agricultural University, Nanchang, Jiangxi, 330045, People's Republic of China
- Jiangxi Key Laboratory for Postharvest Technology and Nondestructive Testing of Fruits & Vegetables/Collaborative Innovation Center of Postharvest Key Technology and Quality Safety of Fruits &Vegetables in Jiangxi Province, Jiangxi Agricultural University, Nanchang, 330045, Jiangxi, China
| | - Xiaoning Liao
- Research Center of Mycotoxin, Jiangxi Agricultural University, Nanchang, Jiangxi, 330045, People's Republic of China
- Jiangxi Key Laboratory for Postharvest Technology and Nondestructive Testing of Fruits & Vegetables/Collaborative Innovation Center of Postharvest Key Technology and Quality Safety of Fruits &Vegetables in Jiangxi Province, Jiangxi Agricultural University, Nanchang, 330045, Jiangxi, China
| | - Yongfa Wu
- Research Center of Mycotoxin, Jiangxi Agricultural University, Nanchang, Jiangxi, 330045, People's Republic of China
- Jiangxi Key Laboratory for Postharvest Technology and Nondestructive Testing of Fruits & Vegetables/Collaborative Innovation Center of Postharvest Key Technology and Quality Safety of Fruits &Vegetables in Jiangxi Province, Jiangxi Agricultural University, Nanchang, 330045, Jiangxi, China
| | - Wanming Xiong
- Jiangxi Key Laboratory for Postharvest Technology and Nondestructive Testing of Fruits & Vegetables/Collaborative Innovation Center of Postharvest Key Technology and Quality Safety of Fruits &Vegetables in Jiangxi Province, Jiangxi Agricultural University, Nanchang, 330045, Jiangxi, China
| | - Juan Du
- Key Lab for Agro-Product Processing and Quality Control of Nanchang City, College of Food Science and Engineering, Jiangxi Agricultural University, Nanchang, 330045, Jiangxi, China
| | - Zhui Tu
- State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang, 330047, Jiangxi, China
| | - Wuying Yang
- Key Lab for Agro-Product Processing and Quality Control of Nanchang City, College of Food Science and Engineering, Jiangxi Agricultural University, Nanchang, 330045, Jiangxi, China
| | - Dan Wang
- Research Center of Mycotoxin, Jiangxi Agricultural University, Nanchang, Jiangxi, 330045, People's Republic of China.
- Key Lab for Agro-Product Processing and Quality Control of Nanchang City, College of Food Science and Engineering, Jiangxi Agricultural University, Nanchang, 330045, Jiangxi, China.
| |
Collapse
|
33
|
Li S, Hu X, Li Y, Tan H. Fluorescent enzyme-linked immunosorbent assay based on alkaline phosphatase-responsive coordination polymer composite. Mikrochim Acta 2021; 188:263. [PMID: 34287706 DOI: 10.1007/s00604-021-04920-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/07/2021] [Accepted: 06/27/2021] [Indexed: 11/24/2022]
Abstract
The fabrication of alkaline phosphatase (ALP)-responsive coordination polymer (CP) composite is demonstrated for establishing a fluorescent immunoassay. The CP composite (ThT@GMP/Eu) was synthesized by encapsulating thioflavin T (ThT) into the CP host that was composed of europium ion (Eu3+) and guanine monophosphate (GMP). The ThT@GMP/Eu composite shows a strong fluorescence in aqueous solution due to the confinement effect of GMP/Eu CPs, which restricts the conformational rotation of ThT. However, upon the addition of ALP, the structure of GMP/Eu CPs was disrupted to release ThT into solution. This results in the quenching of the fluorescence of ThT@GMP/Eu. The fluorescence of ThT@GMP/Eu has a linear response that covers 0.8 to 120 mU/mL ALP with a detection limit of 0.26 mU/mL and exhibits excellent specificity towards ALP against other enzymes. On this basis, inspired by the wide application of ALP as an enzyme label in enzyme-linked immunosorbent assay (ELISA), an ALP-based fluorescent immunoassay was further developed for the detection of mouse immunoglobulin G (mIgG). The developed immunoassay displays a linear fluorescent response towards mIgG from 0.8 to 100 ng/mL, and the detection limit is 0.16 ng/mL. The fluorescent immunoassay was successfully applied to the determination of mIgG in serum samples. Schematic of the responsivity of ThT@GMP/Eu to ALP that hydrolyzes GMP to release ThT, which leads to fluorescent quenching, and its application in the construction of a fluorescent immunoassay for mIgG determination.
Collapse
Affiliation(s)
- Shenghua Li
- College of Biological and Food Engineering, Huaihua University, Huaihua, 418000, People's Republic of China
| | - Xing Hu
- College of Biological and Food Engineering, Huaihua University, Huaihua, 418000, People's Republic of China
| | - Yong Li
- Key Laboratory of Chemical Biology of Jiangxi Province, College of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, 330022, People's Republic of China
| | - Hongliang Tan
- College of Biological and Food Engineering, Huaihua University, Huaihua, 418000, People's Republic of China.
- Key Laboratory of Chemical Biology of Jiangxi Province, College of Chemistry and Chemical Engineering, Jiangxi Normal University, Nanchang, 330022, People's Republic of China.
| |
Collapse
|
34
|
Tran LT, Tran HV, Dang HTM, Nguyen AV, Tran TH, Huynh CD. Electrosynthesis of electrochemically reduced graphene oxide/polyaniline nanowire/silver nanoflower nanocomposite for development of a highly sensitive electrochemical DNA sensor. RSC Adv 2021; 11:19470-19481. [PMID: 35479256 PMCID: PMC9033594 DOI: 10.1039/d1ra01301g] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Accepted: 05/24/2021] [Indexed: 12/03/2022] Open
Abstract
A novel nanostructured electrode material based on electrochemically reduced graphene oxide/polyaniline nanowires/silver nanoflowers (ERGO/PANi NWs/AgNFs) was fabricated site-specifically onto a Pt microelectrode (0.80 mm2 area) using a three-step electrochemical procedure: electrosynthesis of ERGO, electropolymerization of PANi NWs, and electrodeposition of AgNFs. Synergistic and complementary properties of ERGO, PANi NWs and AgNFs, including high electrochemical activity, large surface area, and high biocompatibility, were obtained. Besides, the electrosynthesis method allowed the direct formation of the desired nanomaterial onto the Pt microelectrode, so the adhesion between the sandwich-structured nanocomposite and the electrode surface was also improved. The optimized ERGO/PANi NWs/AgNFs nanocomposite was used for the first time to develop an electrochemical DNA sensor. As a result, the DNA probe immobilization was facilitated and the electrochemical signals of the DNA sensor were enhanced. The detection limit of the DNA sensor was 2.70 × 10−15 M. Moreover, potential miniaturization for fabrication of a lab-on-a-chip system, direct detection, high sensitivity, and good specificity are the advantages of the fabricated DNA sensor. A novel nanostructured material based on ERGO/PANi NWs/AgNFs was electrosynthesized on a Pt microelectrode and was used for the first time to develop an electrochemical DNA sensor.![]()
Collapse
Affiliation(s)
- Luyen Thi Tran
- Hanoi University of Science and Technology 1st Dai Co Viet Road, Hai Ba Trung District Hanoi Vietnam
| | - Hoang Vinh Tran
- Hanoi University of Science and Technology 1st Dai Co Viet Road, Hai Ba Trung District Hanoi Vietnam
| | - Hue Thi Minh Dang
- Hanoi University of Science and Technology 1st Dai Co Viet Road, Hai Ba Trung District Hanoi Vietnam
| | - Anh Van Nguyen
- Hanoi University of Science and Technology 1st Dai Co Viet Road, Hai Ba Trung District Hanoi Vietnam
| | - Thuy Hong Tran
- Hanoi University of Science and Technology 1st Dai Co Viet Road, Hai Ba Trung District Hanoi Vietnam
| | - Chinh Dang Huynh
- Hanoi University of Science and Technology 1st Dai Co Viet Road, Hai Ba Trung District Hanoi Vietnam
| |
Collapse
|
35
|
Analysis of Temperature-Jump Boundary Conditions on Heat Transfer for Heterogeneous Microfluidic Immunosensors. SENSORS 2021; 21:s21103502. [PMID: 34069780 PMCID: PMC8157299 DOI: 10.3390/s21103502] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/08/2020] [Revised: 01/13/2021] [Accepted: 01/28/2021] [Indexed: 12/20/2022]
Abstract
The objective of the current study is to analyze numerically the effect of the temperature-jump boundary condition on heterogeneous microfluidic immunosensors under electrothermal force. A three-dimensional simulation using the finite element method on the binding reaction kinetics of C-reactive protein (CRP) was performed. The kinetic reaction rate was calculated with coupled Laplace, Navier−Stokes, energy, and mass diffusion equations. Two types of reaction surfaces were studied: one in the form of a disc surrounded by two electrodes and the other in the form of a circular ring, one electrode is located inside the ring and the other outside. The numerical results reveal that the performance of a microfluidic biosensor is enhanced by using the second design of the sensing area (circular ring) coupled with the electrothermal force. The improvement factor under the applied ac field 15 Vrms was about 1.2 for the first geometry and 3.6 for the second geometry. Furthermore, the effect of temperature jump on heat transfer rise and response time was studied. The effect of two crucial parameters, viz. Knudsen number (Kn) and thermal accommodation coefficient (σT) with and without electrothermal effect, were analyzed for the two configurations.
Collapse
|
36
|
Kim W, Park J, Kim W, Jo S, Kim M, Kim C, Park H, Bang D, Lee W, Park J. Bio-inspired Ag nanovilli-based sandwich-type SERS aptasensor for ultrasensitive and selective detection of 25-hydroxy vitamin D 3. Biosens Bioelectron 2021; 188:113341. [PMID: 34044348 DOI: 10.1016/j.bios.2021.113341] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2021] [Revised: 04/30/2021] [Accepted: 05/10/2021] [Indexed: 01/02/2023]
Abstract
Vitamin D has been identified as an essential biomarker for various diseases such as rheumatoid arthritis, cancer, and cardiovascular diseases. Recently, many reports have demonstrated a potential link between vitamin D and systemic infections, including coronavirus disease 2019. The villi of the small intestine increase the surface area of the intestinal walls, demonstrating exceptionally efficient absorption of nutrients in the lumen and adding digestive secretions. In this study, based on the villi structure, we developed a bio-inspired silver nanovilli-based sandwich-type surface enhanced Raman scattering aptasensor for the ultrasensitive and selective detection of 25-hydroxy vitamin D3. The densely packed nanovilli structure enhanced the Raman signal, forming hotspots owing to its large surface area. Using experiments and electromagnetic simulations, we optimized the nanovilli structure as a SERS sensor. The sandwich-type aptasensor was designed using an aptamer and 4-Phenyl-1,2,4-triazoline-3,5-dione-methylene blue complex. The nanovilli-based aptasensor could sensitively detect various concentrations of 25-hydroxy vitamin D3, ranging from those found in deficient to excess conditions. The detection limit of the nanovilli-based sandwich-type aptasensor for 25-hydroxy vitamin D3 was 0.001 ng/mL, which is much lower than the deficiency concentration, and was detectable even in the human serum. In addition, our proposed sensor exhibited good repeatability (17.76%) and reproducibility (7.47%). Moreover, the nanovilli-based sandwich-type SERS aptasensor could selectively distinguish 25-hydroxy vitamin D3 from other vitamins. The silver nanovilli-based sandwich-type surface enhanced Raman scattering aptasensor opens a new avenue for the development of a bio-inspired vitamin-sensing platform.
Collapse
Affiliation(s)
- Woochang Kim
- Department of Control and Instrumentation Engineering, Korea University, Sejong, 30019, South Korea
| | - Joohyung Park
- Department of Control and Instrumentation Engineering, Korea University, Sejong, 30019, South Korea
| | - Woong Kim
- Department of Control and Instrumentation Engineering, Korea University, Sejong, 30019, South Korea
| | - Seongjae Jo
- Department of Control and Instrumentation Engineering, Korea University, Sejong, 30019, South Korea; Infectious Disease Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon, 34141, South Korea
| | - Minwoo Kim
- Department of Control and Instrumentation Engineering, Korea University, Sejong, 30019, South Korea
| | - Chihyun Kim
- Department of Control and Instrumentation Engineering, Korea University, Sejong, 30019, South Korea
| | - Hyunjun Park
- Department of Control and Instrumentation Engineering, Korea University, Sejong, 30019, South Korea
| | - Doyeon Bang
- College of AI Convergence, Chonnam National University, Gwangju, 61186, South Korea; Korea Institute of Medical Microrobotics, Gwangju, 61011, South Korea
| | - Wonseok Lee
- Department of Control and Instrumentation Engineering, Korea University, Sejong, 30019, South Korea; Department of Electrical Engineering, Korea National University of Transportation, Chungju, 27469, South Korea.
| | - Jinsung Park
- Department of Control and Instrumentation Engineering, Korea University, Sejong, 30019, South Korea.
| |
Collapse
|
37
|
Wang L, He K, Wang X, Wang Q, Quan H, Wang P, Xu X. Recent progress in visual methods for aflatoxin detection. Crit Rev Food Sci Nutr 2021; 62:7849-7865. [PMID: 33955294 DOI: 10.1080/10408398.2021.1919595] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Abstract
Aflatoxins (AFs) contamination in food and agricultural products poses a significant threat to human health. Sensitive and accurate detection of AFs provides a strong guarantee for ensuring food safety. Conventional chromatographic-based or mass spectrum methods, which rely on bulky instrument and skilled personnel, are not suitable for on-site surveillance. By contrast, visual detections which possess the merits of rapidity and sophisticated instrument-free present an excellent potential for the on-site detection of AFs. This review intends to summarize the latest development of visual methods for AFs detection, including paper-based tests, chromogenic reactions, and luminescent methods. Emerging technologies, like nanotechnology, DNAzymes, and aptamers combined with these visual methods are introduced. The basic principles, features, and application advantages of each type of visual methods are discussed. The biggest challenges and perspectives on their future trends are also addressed.
Collapse
Affiliation(s)
- Liu Wang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Key Laboratory of Information Traceability for Agricultural Products, Ministry of Agriculture and Rural Affairs, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou, China
| | - Kaiyu He
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Key Laboratory of Information Traceability for Agricultural Products, Ministry of Agriculture and Rural Affairs, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou, China
| | - Xinquan Wang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Key Laboratory of Information Traceability for Agricultural Products, Ministry of Agriculture and Rural Affairs, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou, China
| | - Qiang Wang
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Key Laboratory of Information Traceability for Agricultural Products, Ministry of Agriculture and Rural Affairs, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou, China
| | - Haoran Quan
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Key Laboratory of Information Traceability for Agricultural Products, Ministry of Agriculture and Rural Affairs, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou, China
| | - Peilong Wang
- Institute of Quality Standards and Testing Technology for Agro-Products, Chinese Academy of Agricultural Sciences, Beijing, China
| | - Xiahong Xu
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Key Laboratory of Information Traceability for Agricultural Products, Ministry of Agriculture and Rural Affairs, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou, China
| |
Collapse
|
38
|
Li G, Liu C, Zhang X, Luo P, Lin G, Jiang W. Highly photoluminescent carbon dots-based immunosensors for ultrasensitive detection of aflatoxin M 1 residues in milk. Food Chem 2021; 355:129443. [PMID: 33799265 DOI: 10.1016/j.foodchem.2021.129443] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2020] [Revised: 02/17/2021] [Accepted: 02/21/2021] [Indexed: 11/29/2022]
Abstract
Here, a facile hydrothermal method was used to synthesize highly photoluminescent N-doped carbon dots, and the quantum yields reached 97.1%. Then, a label-free immunosensor based on the inner filter effect of carbon dots was developed for ultrasensitive detection of aflatoxin M1 residues in milk. The detection limit was 0.0186 ng/mL (equivalents to 18.10 ng/kg), which satisfied the most stringent maximum tolerable limit value of 25 ng/kg. Besides, the immunosensor showed a good linear relationship from 0.003 ng/mL to 0.81 ng/mL, and the average recoveries ranged from 79.6% to 112.5% for spiked milk samples, with relative standard deviations ranging from 6.7% to 13.3%. Compared with other immunoassays, the inner filter effect-based immunosensor incorporating fluorescent detection into conventional enzymatic cascade amplification systems and could be a reliable on-site screening method for aflatoxin M1 residue analysis.
Collapse
Affiliation(s)
- Guangming Li
- Department of Nutrition and Food Hygiene, School of Public Health, Health Science Center, Shenzhen University, Shenzhen 518060, China; State Key Laboratory of Rare Earth Resource Utilization, Changchun Institute of Applied Chemistry, Changchun 130022, China
| | - Chen Liu
- Shenzhen People's Hospital, Shenzhen 518020, China
| | - Xingcai Zhang
- School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA
| | - Pengjie Luo
- Key Laboratory of Food Safety Risk Assessment, Ministry of Health, China National Center for Food Safety Risk Assessment, Beijing 100021, China
| | - Guimiao Lin
- Department of Nutrition and Food Hygiene, School of Public Health, Health Science Center, Shenzhen University, Shenzhen 518060, China
| | - Wenxiao Jiang
- Department of Nutrition and Food Hygiene, School of Public Health, Health Science Center, Shenzhen University, Shenzhen 518060, China; School of Engineering and Applied Sciences, Harvard University, Cambridge, MA 02138, USA.
| |
Collapse
|
39
|
|
40
|
Gupta R, Raza N, Bhardwaj SK, Vikrant K, Kim KH, Bhardwaj N. Advances in nanomaterial-based electrochemical biosensors for the detection of microbial toxins, pathogenic bacteria in food matrices. JOURNAL OF HAZARDOUS MATERIALS 2021; 401:123379. [PMID: 33113714 DOI: 10.1016/j.jhazmat.2020.123379] [Citation(s) in RCA: 89] [Impact Index Per Article: 22.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Revised: 06/05/2020] [Accepted: 07/01/2020] [Indexed: 05/28/2023]
Abstract
There is a growing demand to protect food products against the hazard of microbes and their toxins. To satisfy such goals, it is important to develop highly sensitive, reliable, sophisticated, rapid, and cost-effective sensing techniques such as electrochemical sensors/biosensors. Although diverse forms of nanomaterials (NMs)-based electrochemical sensing methods have been introduced in markets, the reliability of commercial products is yet insufficient to meet the practical goal. In this review, we focused on: 1) sources of pathogenic microbes and their toxins; 2) possible routes of their entrainment in food, and 3) current development of NM-based biosensors to realize real-time detection of the target analytes. At last, future prospects and challenges in this research field are discussed.
Collapse
Affiliation(s)
- Riya Gupta
- Life Sciences Department, INL-International Iberian Nanotechnology Laboratory, Av. Mestre José Veiga, 4715-330 Braga, Portugal
| | - Nadeem Raza
- Govt. Emerson College Multan Affiliated With Bahauddin Zakaryia University, Multan, Pakistan
| | - Sanjeev K Bhardwaj
- CSIR-Central Scientific Instrument Organisation (CSIR-CSIO), Chandigarh 160030, India
| | - Kumar Vikrant
- Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul, 04763, Republic of Korea
| | - Ki-Hyun Kim
- Department of Civil and Environmental Engineering, Hanyang University, 222 Wangsimni-Ro, Seoul, 04763, Republic of Korea.
| | - Neha Bhardwaj
- Department of Biotechnology, University Institute of Engineering and Technology, Panjab University (PU), Sector 25, Chandigarh, India.
| |
Collapse
|
41
|
An Impedance Based Electrochemical Immunosensor for Aflatoxin B1 Monitoring in Pistachio Matrices. CHEMOSENSORS 2020. [DOI: 10.3390/chemosensors8040121] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Aflatoxins are highly toxic fungal secondary metabolites that often contaminate food and feed commodities. An electrochemical immunosensor for the determination of aflatoxin B1 (AFB1) was fabricated by immobilizing monoclonal AFB1 antibodies onto a screen-printed gold electrode that was modified with carbo-methyldextran by N-(3-dimethylaminopropyl)-N′-ethylcarbodiimide hydrochloride/N-hydroxysuccinimide cross-linking. An electrochemical interfacial modelling of biomolecular recognition was suggested and reasonably interpreted. Impedance technology was employed for the quantitative determination of AFB1. The limit of detection concentration of AFB1 for standard solutions and spiked pistachio samples was 0.5 ng/mL and 1 ng/mL, respectively. The immunosensor was able to successfully determine AFB1 concentrations in the range of 4.56–50.86 ng/mL in unknown pistachio samples. Comparative chromatographic analysis revealed that AFB1 concentrations that were higher than 345 ng/mL were not within the immunosensor’s upper limits of detection. Selectivity studies against Ochratoxin A and Aflatoxin M1 demonstrated that the proposed AFB1 immunosensor was able to differentiate between these other fungal mycotoxins. The novel electrochemical immunosensor approach has the potential for rapid sample screening in a portable, disposable format, thus contributing to the requirement for effective prevention and the control of aflatoxin B1 in pistachios.
Collapse
|
42
|
Wang X, Li F, Guo Y. Recent Trends in Nanomaterial-Based Biosensors for Point-of-Care Testing. Front Chem 2020; 8:586702. [PMID: 33195085 PMCID: PMC7596383 DOI: 10.3389/fchem.2020.586702] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2020] [Accepted: 09/07/2020] [Indexed: 12/15/2022] Open
Abstract
In recent years, nanomaterials of different shape, size, and composition have been prepared and characterized, such as gold and silver nanoparticles, quantum dots, mesoporous silica nanoparticles, carbon nanomaterials, and hybrid nanocomposites. Because of their unique physical and chemical properties, these nanomaterials are increasingly used in point-of-care testing (POCT) to improve analytical performance and simplify detection process. They are used either as carriers for immobilizing biorecognition elements, or as labels for signal generation, transduction and amplification. In this commentary, we highlight recent POCT technologies that employ nanotechnology for the analysis of disease biomarkers, including small-molecule metabolites, enzymes, proteins, nucleic acids, cancer cells, and pathogens. Recent advances in lateral flow tests, printable electrochemical biosensors, and microfluidics-based devices are summarized. Existing challenges and future directions are also discussed.
Collapse
Affiliation(s)
- Xu Wang
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA, United States
| | - Feng Li
- College of Chemistry, Sichuan University, Chengdu, China.,Department of Chemistry, Brock University, St. Catharines, ON, Canada
| | - Yirong Guo
- Institute of Pesticide and Environmental Toxicology, Zhejiang University, Hangzhou, China
| |
Collapse
|
43
|
Zhang X, Li G, Wu D, Liu J, Wu Y. Recent advances on emerging nanomaterials for controlling the mycotoxin contamination: From detection to elimination. FOOD FRONTIERS 2020. [DOI: 10.1002/fft2.42] [Citation(s) in RCA: 29] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Affiliation(s)
- Xianlong Zhang
- School of Food and Biological Engineering Shaanxi University of Science and Technology Xi'an China
| | - Guoliang Li
- School of Food and Biological Engineering Shaanxi University of Science and Technology Xi'an China
| | - Di Wu
- Institute for Global Food Security, School of Biological Sciences Queen's University Belfast Belfast United Kingdom
| | - Jianghua Liu
- School of Food and Biological Engineering Shaanxi University of Science and Technology Xi'an China
| | - Yongning Wu
- NHC Key Laboratory of Food Safety Risk Assessment, Food Safety Research Unit (2019RU014) of Chinese Academy of Medical Science China National Center for Food Safety Risk Assessment Beijing China
| |
Collapse
|
44
|
Yan C, Wang Q, Yang Q, Wu W. Recent Advances in Aflatoxins Detection Based on Nanomaterials. NANOMATERIALS 2020; 10:nano10091626. [PMID: 32825088 PMCID: PMC7558307 DOI: 10.3390/nano10091626] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 08/14/2020] [Accepted: 08/16/2020] [Indexed: 12/31/2022]
Abstract
Aflatoxins are the secondary metabolites of Aspergillus flavus and Aspergillus parasiticus and are highly toxic and carcinogenic, teratogenic and mutagenic. Ingestion of crops and food contaminated by aflatoxins causes extremely serious harm to human and animal health. Therefore, there is an urgent need for a selective, sensitive and simple method for the determination of aflatoxins. Due to their high performance and multipurpose characteristics, nanomaterials have been developed and applied to the monitoring of various targets, overcoming the limitations of traditional methods, which include process complexity, time-consuming and laborious methodologies and the need for expensive instruments. At the same time, nanomaterials provide general promise for the detection of aflatoxins with high sensitivity, selectivity and simplicity. This review provides an overview of recent developments in nanomaterials employed for the detection of aflatoxins. The basic aspects of aflatoxin toxicity and the significance of aflatoxin detection are also reviewed. In addition, the development of different biosensors and nanomaterials for aflatoxin detection is introduced. The current capabilities and limitations and future challenges in aflatoxin detection and analysis are also addressed.
Collapse
Affiliation(s)
- Chunlei Yan
- College of Food Science and Engineering, Qingdao Agricultural University, Qingdao 266109, China; (C.Y.); (Q.W.)
| | - Qi Wang
- College of Food Science and Engineering, Qingdao Agricultural University, Qingdao 266109, China; (C.Y.); (Q.W.)
| | - Qingli Yang
- College of Food Science and Engineering, Qingdao Agricultural University, Qingdao 266109, China; (C.Y.); (Q.W.)
- Correspondence: (Q.Y.); (W.W.)
| | - Wei Wu
- College of Food Science and Engineering, Qingdao Agricultural University, Qingdao 266109, China; (C.Y.); (Q.W.)
- State Key Laboratory of Bio-Fibers and Eco-Textiles, Institute of Biochemical Engineering, College of Materials Science and Engineering, Qingdao University, Qingdao 266071, China
- Correspondence: (Q.Y.); (W.W.)
| |
Collapse
|
45
|
Amde M, Temsgen A, Dechassa N. Ionic liquid functionalized zinc oxide nanorods for solid-phase microextraction of aflatoxins in food products. J Food Compost Anal 2020. [DOI: 10.1016/j.jfca.2020.103528] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
46
|
Setlem K, Mondal B, Shylaja R, Parida M. Dual Aptamer-DNAzyme based colorimetric assay for the detection of AFB1 from food and environmental samples. Anal Biochem 2020; 608:113874. [PMID: 32750356 DOI: 10.1016/j.ab.2020.113874] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/27/2020] [Revised: 07/06/2020] [Accepted: 07/13/2020] [Indexed: 02/07/2023]
Abstract
In the present study, a colorimetric biosensor strategy is devised in combination with apta-magnetic separation assisted with DNAzyme based colorimetric detection of Aflatoxin B1 (AFB1). The optimized analytical procedures consisted of the capture of AFB1 by biotinylated aptamer conjugated to streptavidin magnetic beads and detection by a colorimetric signal from a DNAzyme modified aptamer in presence hemin and H2O2/TMB (3', 3', 5, 5'- tetramethylbenzidine). The DNA concentration, incubation time, hemin, and NaCl concentrations were evaluated and optimized. The visual optical signal thus generated could determine the presence of AFB1 in the given sample. The selectivity of the method with other mycotoxins was evaluated. The linear range of AFB1 from 0 to 200 ppb was assessed and detected as low as 40 ppb visually. The absorbance of blue color generated by the catalytic reaction was in a linear correlation with AFB1 concentrations and was able to detect as low as 22.6 ppb (LOD). The suitability of the assay for AFB1 quantification in sorghum and natural samples was also evaluated. Thus, the developed assay could be a reliable, inexpensive, alternative tool for possible use as a screening method for aflatoxins and other mycotoxins.
Collapse
Affiliation(s)
| | - Bhairab Mondal
- Defence Food Research Laboratory (DFRL), Mysore, 570011, India.
| | - R Shylaja
- Defence Food Research Laboratory (DFRL), Mysore, 570011, India.
| | - Manmohan Parida
- Defence Food Research Laboratory (DFRL), Mysore, 570011, India.
| |
Collapse
|
47
|
Aspergillus Species Discrimination Using a Gas Sensor Array. SENSORS 2020; 20:s20144004. [PMID: 32708481 PMCID: PMC7412133 DOI: 10.3390/s20144004] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/25/2020] [Revised: 07/10/2020] [Accepted: 07/15/2020] [Indexed: 11/17/2022]
Abstract
The efficiency of electronic noses in detecting and identifying microorganisms has been proven by several studies. Since volatile compounds change with the growth of colonies, the identification of strains is highly dependent on the growing conditions. In this paper, the effects of growth were investigated with different species of Aspergillus, which is one of the most studied microorganisms because of its implications in environmental and food safety. For this purpose, we used an electronic nose previously utilized for volatilome detection applications and based on eight porphyrins-functionalized quartz microbalances. The volatile organic compounds (VOCs) released by cultured fungi were measured at 3, 5, and 10 days after the incubation. The signals from the sensors showed that the pattern of VOCs evolve with time. In particular, the separation between the three studied strains progressively decreases with time. The three strains could still be identified despite the influence of culture time. Linear Discriminant Analysis (LDA) showed an overall accuracy of 88% and 71% in the training and test sets, respectively. These results indicate that the presence of microorganisms is detectable with respect to background, however, the difference between the strains changes with the incubation time.
Collapse
|
48
|
Speranskaya ES, Drozd DD, Pidenko PS, Goryacheva IY. Enzyme modulation of quantum dot luminescence: Application in bioanalysis. Trends Analyt Chem 2020. [DOI: 10.1016/j.trac.2020.115897] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/22/2022]
|
49
|
Seddaoui N, Amine A. A sensitive colorimetric immunoassay based on poly(dopamine) modified magnetic nanoparticles for meat authentication. Lebensm Wiss Technol 2020. [DOI: 10.1016/j.lwt.2020.109045] [Citation(s) in RCA: 20] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023]
|
50
|
Electrochemical microfluidic immunosensor based on TES-AuNPs@Fe3O4 and CMK-8 for IgG anti-Toxocara canis determination. Anal Chim Acta 2020; 1096:120-129. [DOI: 10.1016/j.aca.2019.10.040] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Accepted: 10/20/2019] [Indexed: 12/19/2022]
|