1
|
Huang C, Liu R, Ding Y, Zhao L, Zhu Z, Li Q, Jiang D, Wu Y, Yu X, Ding S, Gao X, Zhu R. Template-assembly activation of primer exchange reaction for on-site and sensitive detection of copper ions in blood. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 330:125702. [PMID: 39793253 DOI: 10.1016/j.saa.2025.125702] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2024] [Revised: 01/01/2025] [Accepted: 01/02/2025] [Indexed: 01/13/2025]
Abstract
The sensitive and accurate detection of copper ions is crucial for public health, medical research, and environmental monitoring. In this study, we developed a sensor based on template-assembly activation of the primer exchange reaction (PER) for the on-site detection of copper ions in blood. Copper ions triggered the assembly of two template fragments into a hairpin structure via a click-chemistry reaction, activating the PER. Polymerase then repeatedly guided the polymerization of multiple primers along the assembled PER template, generating amplified products containing G-triplex sequences. These G-triplex structures specifically enhanced the fluorescence of thioflavin T and exhibited peroxidase-like activity, serving as dual-functional signal reporters for both fluorescence and colorimetric outputs. The sensor effectively amplified a single copper ion signal into multiple G-triplex signals, achieving high sensitivity with detection limits of 68.5 nM in fluorescence mode and 70.4 nM in colorimetric mode. The system also demonstrated strong selectivity, due to the high specificity of the click-chemistry reaction for copper ions. The dual-mode detection minimized false signals and improved accuracy through cross-verification. Additionally, both fluorescence and colorimetric signals were easily measurable without complex instrumentation, enabling flexible application. The method was successfully applied to blood samples, showcasing its robust performance. This sensor offers a promising alternative for copper ion detection with broad potential applications in public health, medical research, and environmental monitoring.
Collapse
Affiliation(s)
- Chao Huang
- The First Clinical Medical College, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China; Department of Pharmacy, Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan 250014, PR China
| | - Rui Liu
- Nanchang Center for Disease Control and Prevention, Nanchang, PR China; Department of Physical and Chemical Inspection, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan 250000, PR China
| | - Yue Ding
- College of Pharmacy, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China
| | - Linlin Zhao
- The Second Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan 250000, PR China
| | - Zongmin Zhu
- The First Clinical Medical College, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China; Department of Pharmacy, Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan 250014, PR China
| | - Qiyan Li
- Shandong Institute for Food and Drug Control, Shandong Research Center of Engineering and Technology for Safety Inspection of Food and Drug, Jinan 250101, PR China
| | - Dafeng Jiang
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, Jinan 250001, PR China
| | - Yuxin Wu
- Department of Physical and Chemical Inspection, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan 250000, PR China
| | - Xuemei Yu
- Rizhao Hospital of Traditional Chinese Medicine, Rizhao 276800, PR China
| | - Shengyong Ding
- The First Clinical Medical College, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China; Department of Pharmacy, Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan 250014, PR China.
| | - Xibao Gao
- Department of Physical and Chemical Inspection, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan 250000, PR China.
| | - Riran Zhu
- The First Clinical Medical College, Shandong University of Traditional Chinese Medicine, Jinan, 250355, PR China; Department of Pharmacy, Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan 250014, PR China.
| |
Collapse
|
2
|
Geng L, Liu J, Zhang W, Wang H, Huang J, Wang G, Hu M, Dong H, Sun J, Fang M, Guo Y, Sun X. Preparation of dual recognition adsorbents based on molecularly imprinted polymers and aptamer for highly sensitive recognition and enrichment of ochratoxin A. JOURNAL OF HAZARDOUS MATERIALS 2024; 476:135112. [PMID: 38981234 DOI: 10.1016/j.jhazmat.2024.135112] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/05/2024] [Revised: 07/02/2024] [Accepted: 07/04/2024] [Indexed: 07/11/2024]
Abstract
In light of the significant risks that mycotoxins posed to public health and environmental safety, this research developed an adsorbent MIPs/Apt/AuNPs@ZIF-67 (MA-AZ) utilizing a dual-recognition approach combining molecularly imprinted polymers (MIPs) and aptamer (Apt). This innovative method enabled the effective and highly selective recognition and enrichment of ochratoxin A (OTA). ZIF-67 was utilized as a carrier with a substantial specific surface area, and gold nanoparticles (AuNPs) were loaded on its surface to fix the thiol-modified Apt on the surface of the carrier. Then, an initiator was used to initiate a polymerization reaction, and the generated MIPs coated Apt/AuNPs@ZIF-67, thereby synthesizing the MA-AZ with a "synergistic recognition" effect. The Apt significantly increased the number of recognition sites within the imprinted cavities, and MIPs played roles in identifying targets, fixing and protecting Apt. The combination of the both produced the effect of "1+1>2". The study on the adsorption performance of MA-AZ found that the adsorption capacity of MA-AZ could reach 65.1 mg/g, and the imprinted factor was 5.48. In addition, MA-AZ exhibited excellent stability, specificity, reusability and recovery rate. Thus, this study offers valuable insights for the recognition and enrichment of hazardous substances, and helps to promote the rapid development of safety detection.
Collapse
Affiliation(s)
- Lingjun Geng
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Jingjing Liu
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Wenbin Zhang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Haifang Wang
- Dongzhimen Hospital, Beijing University of Chinese Medicine, Beijing 100700, China
| | - Jingcheng Huang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Guangxian Wang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Mengjiao Hu
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Haowei Dong
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Jiashuai Sun
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Mingxuan Fang
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China
| | - Yemin Guo
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China.
| | - Xia Sun
- School of Agricultural Engineering and Food Science, Shandong University of Technology, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Shandong Provincial Engineering Research Center of Vegetable Safety and Quality Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China; Zibo City Key Laboratory of Agricultural Product Safety Traceability, No. 266 Xincun Xilu, Zibo, Shandong 255049, China.
| |
Collapse
|
3
|
Huang C, Jiao Y, Shao L, Li W, Ding S, Jiang D, Jiang W. Ultrasensitive detection of the H5N1 nucleic acid fragment by ICP-MS using DNA dendrimer-carried silver nanoparticle labeling. Analyst 2024; 149:4363-4369. [PMID: 39007642 DOI: 10.1039/d4an00746h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/16/2024]
Abstract
The importance of avian influenza virus (AIV) detection in clinical diagnosis and prognosis has been deeply recognized. In this study, the ultrasensitive detection of AIV subtype H5N1 was achieved by ICP-MS combined with DNA dendrimer-carried silver nanoparticle (AgNP) labeling. First, a magnetic control system was constructed by anchoring double-strand DNAs (dsDNAs) which contained a complementary sequence of H5N1 and two locked triggers on the surface of magnetic beads (MBs). When H5N1 was present, the two triggers were released and initiated dendrimer hybridization chain reactions which led to the generation of DNA dendrimer-carried AgNPs on the surface of the MBs. Finally, the AgNPs were collected via magnetic separation, digested by nitric acid, and tested using ICP-MS. The signal intensities of 107Ag were positively correlated with the concentrations of H5N1. Notably, the DNA dendrimer assembly contributed to significant signal amplification and good sensitivity with the limit of detection as low as 2.0 × 10-11 mol L-1. Moreover, the method displayed favorable selectivity against mismatched H5N1 and good recoveries in human serum samples. It is a promising analytical tool for the H5N1 virus and other subtypes of AIV, and has potential value in clinical diagnosis and prognosis of infectious diseases.
Collapse
Affiliation(s)
- Chao Huang
- School of Chemistry and Chemical Engineering, Shandong University, 250100 Jinan, P. R. China.
- Department of Pharmacy, Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan 250014, P. R. China
- College of Pharmacy, Shandong University of Traditional Chinese Medicine, 250355 Jinan, P.R. China
| | - Yanni Jiao
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, 250014 Jinan, P. R. China.
| | - Lijun Shao
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, 250014 Jinan, P. R. China.
| | - Wei Li
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, 250014 Jinan, P. R. China.
| | - Shengyong Ding
- Department of Pharmacy, Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan 250014, P. R. China
| | - Dafeng Jiang
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, 250014 Jinan, P. R. China.
| | - Wei Jiang
- School of Chemistry and Chemical Engineering, Shandong University, 250100 Jinan, P. R. China.
| |
Collapse
|
4
|
Dong N, Liu S, Meng S, Chen Z, Li Y, Liu D, You T. Light-Driven Electrochemical Biosensing with DNA Origami-Assisted Hybrid Nanoantenna for Fumonisin B1 Monitoring. Anal Chem 2024; 96:12809-12816. [PMID: 39042055 DOI: 10.1021/acs.analchem.4c02258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/24/2024]
Abstract
The electrochemical detection of biosensors is largely governed by the changes in physical properties of redox probes, which are susceptible to electrode substrate effects, inhibiting sensor sensitivity. In this work, a light-driven electrochemical biosensor based on a hybrid nanoantenna was developed for the sensitive detection of fumonisin B1 (FB1). The hybrid nanoantenna sensing interface was constructed by coupling CdSe quantum dots (QDs)-DNA nanowire and graphdiyne oxide composites loaded with methylene blue and gold nanorods (GDYO-MB-Au NRs) using a tetrahedral DNA nanostructure, which acted as a light-driven unit and an amplification unit, respectively. The hybrid nanoantenna with light-driven properties facilitated the alteration in the chemical properties of MB at the sensing interface; that is, MB was degraded under light illumination. The stripping of the CdSe QDs-DNA nanowire triggered by the binding of FB1 could degrade the light-driven capability, thereby improving the electrochemical signal through depressing MB degradation. Taking advantage of the photodegradation of MB by the hybrid nanoantenna, the developed biosensor reduced the background signal and increased the detection sensitivity. The developed biosensor exhibited a linear detection range from 0.5 fg mL-1 to 10 pg mL-1 and a detection limit down to 0.45 fg mL-1. This strategy shows great promise for the fabrication of highly sensitive electrochemical biosensors.
Collapse
Affiliation(s)
- Na Dong
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China
| | - Shuda Liu
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China
| | - Shuyun Meng
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China
| | - Zuo Chen
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China
| | - Yuye Li
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China
| | - Dong Liu
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang, Jiangsu 212013, China
| | - Tianyan You
- College of Agricultural Equipment Engineering, Henan University of Science and Technology, Luoyang, Henan 471003, China
| |
Collapse
|
5
|
Khan R, Anwar F, Ghazali FM. A comprehensive review of mycotoxins: Toxicology, detection, and effective mitigation approaches. Heliyon 2024; 10:e28361. [PMID: 38628751 PMCID: PMC11019184 DOI: 10.1016/j.heliyon.2024.e28361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2023] [Revised: 01/19/2024] [Accepted: 01/21/2024] [Indexed: 04/19/2024] Open
Abstract
Mycotoxins, harmful compounds produced by fungal pathogens, pose a severe threat to food safety and consumer health. Some commonly produced mycotoxins such as aflatoxins, ochratoxin A, fumonisins, trichothecenes, zearalenone, and patulin have serious health implications in humans and animals. Mycotoxin contamination is particularly concerning in regions heavily reliant on staple foods like grains, cereals, and nuts. Preventing mycotoxin contamination is crucial for a sustainable food supply. Chromatographic methods like thin layer chromatography (TLC), gas chromatography (GC), high-performance liquid chromatography (HPLC), and liquid chromatography coupled with a mass spectrometer (LC/MS), are commonly used to detect mycotoxins; however, there is a need for on-site, rapid, and cost-effective detection methods. Currently, enzyme-linked immunosorbent assays (ELISA), lateral flow assays (LFAs), and biosensors are becoming popular analytical tools for rapid detection. Meanwhile, preventing mycotoxin contamination is crucial for food safety and a sustainable food supply. Physical, chemical, and biological approaches have been used to inhibit fungal growth and mycotoxin production. However, new strains resistant to conventional methods have led to the exploration of novel strategies like cold atmospheric plasma (CAP) technology, polyphenols and flavonoids, magnetic materials and nanoparticles, and natural essential oils (NEOs). This paper reviews recent scientific research on mycotoxin toxicity, explores advancements in detecting mycotoxins in various foods, and evaluates the effectiveness of innovative mitigation strategies for controlling and detoxifying mycotoxins.
Collapse
Affiliation(s)
- Rahim Khan
- Department of Food Science, Faculty of Food Science and Technology, Universiti Putra Malaysia, 43400, UPM, Serdang, Malaysia
| | - Farooq Anwar
- Department of Food Science, Faculty of Food Science and Technology, Universiti Putra Malaysia, 43400, UPM, Serdang, Malaysia
- Institute of Chemistry, University of Sargodha, Sargodha, 40100, Pakistan
| | - Farinazleen Mohamad Ghazali
- Department of Food Science, Faculty of Food Science and Technology, Universiti Putra Malaysia, 43400, UPM, Serdang, Malaysia
| |
Collapse
|
6
|
Zhang T, Huang C, Jiao Y, Shao L, Jiang D, Li F, Li W, Gao X. ICP-MS and fluorescence dual-mode detection of ZIKV-RNA based on quantum dot labeling with hybridization chain reaction. Talanta 2024; 269:125463. [PMID: 38016323 DOI: 10.1016/j.talanta.2023.125463] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2023] [Revised: 10/04/2023] [Accepted: 11/21/2023] [Indexed: 11/30/2023]
Abstract
The detection of Zika virus (ZIKV) is of great significance to human life and health. Herein, we presented an ICP-MS and fluorescent dual-mode sensor for quantitative analysis of Zika virus RNA fragments (ZIKV-RNA), which employed quantum dots (QDs) as signal tags and combined with hybridization chain reaction (HCR). The dual-mode sensor realized cross-checking of the analysis results and improved the assay accuracy. Firstly, the single-stranded DNA (ssDNA) was anchored on the surface of magnetic beads (MBs). Afterward, HCR was conducted with probe DNA-CdSe quantum dots conjugates (pDNA-QDs) and link DNA (lDNA), producing the MBs-ssDNA-[pDNA-QDs-lDNA]n conjugates. In the presence of target ZIKV-RNA, a strand displacement reaction occurred, leading to the dissociation of the [pDNA-QDs-lDNA]n labels from the conjugates into the solution. Finally, the signal intensity was detected using ICP-MS and fluorescence analysis, with achieved limits of detection of 131 pM and 152 pM, respectively. The inter-assay RSD values of fluorescence and ICP-MS were 3.94 % and 4.26 % at 10 nM level, respectively, showing that the method had good precision. This method showed high selectivity and was applied to the analysis of biological fluids. There was no significant difference between the results of ICP-MS modes and fluorescence mode. This method offers a new strategy for sensitivity analysis of ZIKV-RNA and exhibits promise in clinical applications for diagnosis.
Collapse
Affiliation(s)
- Tianran Zhang
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, Jinan, 250000, People's Republic of China; Department of Physical and Chemical Inspection, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, 250000, People's Republic of China; Yantai Center for Disease Control and Prevention, Yantai, 264000, People's Republic of China
| | - Chao Huang
- Department of Pharmacy, Affiliated Hospital of Shandong University of Traditional Chinese Medicine, Jinan, 250014, People's Republic of China
| | - Yanni Jiao
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, Jinan, 250000, People's Republic of China; Department of Physical and Chemical Inspection, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, 250000, People's Republic of China
| | - Lijun Shao
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, Jinan, 250000, People's Republic of China
| | - Dafeng Jiang
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, Jinan, 250000, People's Republic of China; Department of Physical and Chemical Inspection, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, 250000, People's Republic of China.
| | - Fenghua Li
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, Jinan, 250000, People's Republic of China
| | - Wei Li
- Shandong Academy of Preventive Medicine, Shandong Center for Food Safety Risk Assessment, Shandong Center for Disease Control and Prevention, Jinan, 250000, People's Republic of China
| | - Xibao Gao
- Department of Physical and Chemical Inspection, School of Public Health, Cheeloo College of Medicine, Shandong University, Jinan, 250000, People's Republic of China.
| |
Collapse
|
7
|
Billet B, Chovelon B, McConnell EM, André D, Puillet-Anselme L, Fiore E, Faure P, Ravelet C, DeRosa MC, Peyrin E. Iodinated organic molecule as tag for inductively coupled Plasma-mass spectrometry aptamer assays. Talanta 2024; 267:125107. [PMID: 37672983 DOI: 10.1016/j.talanta.2023.125107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2023] [Revised: 08/09/2023] [Accepted: 08/21/2023] [Indexed: 09/08/2023]
Abstract
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS) aptamer-based assays using metallic nanostructures or chelates as exogenous tags have gained growing attention in the last decade. We describe here a proof-of-concept study based on the exploitation of a simple organic molecule as a tag, i.e.l-thyroxine carrying four iodine atoms detectable by ICP-MS. A solid-phase assay involving the structure-switching format was deployed for the detection of the small molecule l-tyrosinamide as model target. The overall design involved (i) a reporter agent consisting of a DNA aptamer incorporating a single l-thyroxine label at its end and (ii) a capture agent, which is a partially complementary strand, immobilized on a microplate. Limit of detection in the nanomolar range was reported. The present labeling approach was further developed for the detection of a model protein (α-thrombin), using a sandwich mode, and proved effective in a biological matrix. We believe that the l-thyroxine tagging method could become a simple and robust alternative to commonly used labeling methods for ICP-MS aptamer-based assays.
Collapse
Affiliation(s)
- Blandine Billet
- University Grenoble Alpes, DPM UMR, 5063, F-38041, Grenoble, France; CNRS, DPM UMR, 5063, F-38041, Grenoble, France; Biochemistry, Toxicology and Pharmacology Department, Grenoble Site Nord CHU, Biology and Pathology Institute, F-38041, Grenoble, France
| | - Benoit Chovelon
- University Grenoble Alpes, DPM UMR, 5063, F-38041, Grenoble, France; CNRS, DPM UMR, 5063, F-38041, Grenoble, France; Biochemistry, Toxicology and Pharmacology Department, Grenoble Site Nord CHU, Biology and Pathology Institute, F-38041, Grenoble, France; Department of Chemistry, Carleton University, Ottawa, Canada.
| | | | - Dominique André
- Biochemistry, Toxicology and Pharmacology Department, Grenoble Site Nord CHU, Biology and Pathology Institute, F-38041, Grenoble, France
| | - Laurence Puillet-Anselme
- Biochemistry, Toxicology and Pharmacology Department, Grenoble Site Nord CHU, Biology and Pathology Institute, F-38041, Grenoble, France
| | - Emmanuelle Fiore
- University Grenoble Alpes, DPM UMR, 5063, F-38041, Grenoble, France; CNRS, DPM UMR, 5063, F-38041, Grenoble, France
| | - Patrice Faure
- University Grenoble Alpes, DPM UMR, 5063, F-38041, Grenoble, France; CNRS, DPM UMR, 5063, F-38041, Grenoble, France; Biochemistry, Toxicology and Pharmacology Department, Grenoble Site Nord CHU, Biology and Pathology Institute, F-38041, Grenoble, France
| | - Corinne Ravelet
- University Grenoble Alpes, DPM UMR, 5063, F-38041, Grenoble, France; CNRS, DPM UMR, 5063, F-38041, Grenoble, France
| | - Maria C DeRosa
- Department of Chemistry, Carleton University, Ottawa, Canada
| | - Eric Peyrin
- University Grenoble Alpes, DPM UMR, 5063, F-38041, Grenoble, France; CNRS, DPM UMR, 5063, F-38041, Grenoble, France.
| |
Collapse
|
8
|
Gao S, Zhou R, Zhang D, Zheng X, El-Seedi HR, Chen S, Niu L, Li X, Guo Z, Zou X. Magnetic nanoparticle-based immunosensors and aptasensors for mycotoxin detection in foodstuffs: An update. Compr Rev Food Sci Food Saf 2024; 23:e13266. [PMID: 38284585 DOI: 10.1111/1541-4337.13266] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Revised: 10/06/2023] [Accepted: 10/15/2023] [Indexed: 01/30/2024]
Abstract
Mycotoxin contamination of food crops is a global challenge due to their unpredictable occurrence and severe adverse health effects on humans. Therefore, it is of great importance to develop effective tools to prevent the accumulation of mycotoxins through the food chain. The use of magnetic nanoparticle (MNP)-assisted biosensors for detecting mycotoxin in complex foodstuffs has garnered great interest due to the significantly enhanced sensitivity and accuracy. Within such a context, this review includes the fundamentals and recent advances (2020-2023) in the area of mycotoxin monitoring in food matrices using MNP-based aptasensors and immunosensors. In this review, we start by providing a comprehensive introduction to the design of immunosensors (natural antibody or nanobody, random or site-oriented immobilization) and aptasensors (techniques for aptamer selection, characterization, and truncation). Meanwhile, special attention is paid to the multifunctionalities of MNPs (recoverable adsorbent, versatile carrier, and signal indicator) in preparing mycotoxin-specific biosensors. Further, the contribution of MNPs to the multiplexing determination of various mycotoxins is summarized. Finally, challenges and future perspectives for the practical applications of MNP-assisted biosensors are also discussed. The progress and updates of MNP-based biosensors shown in this review are expected to offer readers valuable insights about the design of MNP-based tools for the effective detection of mycotoxins in practical applications.
Collapse
Affiliation(s)
- Shipeng Gao
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, China
| | - Ruiyun Zhou
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, China
- Focusight Technology (Jiangsu) Co., LTD, Changzhou, China
| | - Di Zhang
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, China
| | - Xueyun Zheng
- Key Laboratory of Fermentation Engineering (Ministry of Education), School of Biological Engineering and Food, Hubei University of Technology, Wuhan, China
| | - Hesham R El-Seedi
- International Joint Research Laboratory of Intelligent Agriculture and Agri-Products Processing (Jiangsu Education Department), Zhenjiang, China
- International Research Center for Food Nutrition and Safety, Jiangsu University, Zhenjiang, China
| | - Shiqi Chen
- Chongqing Institute for Food and Drug Control, Chongqing, China
| | - Lidan Niu
- Chongqing Institute for Food and Drug Control, Chongqing, China
| | - Xin Li
- Jiangsu Hengshun vinegar Industry Co., Ltd., Zhenjiang, China
| | - Zhiming Guo
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, China
- International Joint Research Laboratory of Intelligent Agriculture and Agri-Products Processing (Jiangsu Education Department), Zhenjiang, China
| | - Xiaobo Zou
- School of Food and Biological Engineering, Jiangsu University, Zhenjiang, China
| |
Collapse
|
9
|
Torregrosa D, Jauset-Rubio M, Serrano R, Svobodová M, Grindlay G, O'Sullivan CK, Mora J. Ultrasensitive determination of β-conglutin food allergen by means an aptamer assay based on inductively coupled plasma mass spectrometry detection. Anal Chim Acta 2023; 1252:341042. [PMID: 36935136 DOI: 10.1016/j.aca.2023.341042] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2022] [Revised: 03/01/2023] [Accepted: 03/02/2023] [Indexed: 03/06/2023]
Abstract
The overall objective of this work is the evaluation of different competitive aptamer assays based on inductively coupled plasma mass spectrometry (ICP-MS) detection for the determination of β-conglutin (food protein allergen from lupin) in flour samples. To this end, two competitive aptamer assay schemes were developed using either thiolated aptamers chemisorbed onto gold nanoparticles (AuNPs) or biotinylated aptamers linked to streptavidin-AuNPs. The influence of ICP-MS detection mode (i.e., conventional vs single particle) on assay performance was explored. In the case of the thiolated aptamer, the limit of detection (LoD) obtained using the single particle mode was improved 2-fold as compared to the LoD provided by the conventional mode. With regards to the biotinylated aptamer, the use of the conventional mode provided a 5-fold improvement of LoD as compared to that obtained for the single particle one. Using the optimized conditions, the best LoD of 2 pM was obtained with the biotinylated aptamer operating with conventional ICP-MS detection. When compared to previous reports using the same aptamer in a competitive assay, the developed method significantly improved the LoD by at least an order of magnitude. Different flour samples containing lupin were successfully analyzed according to European Conformity guidelines for the analysis of food contaminants.
Collapse
Affiliation(s)
- Daniel Torregrosa
- University of Alicante, Department of Analytical Chemistry, Nutrition and Food Sciences, PO Box 99, 03080, Alicante, Spain
| | - Miriam Jauset-Rubio
- INTERFIBIO Consolidated Research Group, Department of Chemical Engineering, Universitat Rovira i Virgili, 43007, Tarragona, Spain
| | - Raquel Serrano
- University of Alicante, Department of Analytical Chemistry, Nutrition and Food Sciences, PO Box 99, 03080, Alicante, Spain
| | - Marketa Svobodová
- INTERFIBIO Consolidated Research Group, Department of Chemical Engineering, Universitat Rovira i Virgili, 43007, Tarragona, Spain
| | - Guillermo Grindlay
- University of Alicante, Department of Analytical Chemistry, Nutrition and Food Sciences, PO Box 99, 03080, Alicante, Spain.
| | - Ciara K O'Sullivan
- INTERFIBIO Consolidated Research Group, Department of Chemical Engineering, Universitat Rovira i Virgili, 43007, Tarragona, Spain; Institució Catalana de Recerca i Estudis Avancats (ICREA), 08010, Barcelona, Spain
| | - Juan Mora
- University of Alicante, Department of Analytical Chemistry, Nutrition and Food Sciences, PO Box 99, 03080, Alicante, Spain
| |
Collapse
|
10
|
Zhu C, Liu X, Li Y, Yu D, Gao Q, Chen L. Dual-ratiometric electrochemical aptasensor based on carbon nanohorns/anthraquinone-2-carboxylic acid/Au nanoparticles for simultaneous detection of malathion and omethoate. Talanta 2023; 253:123966. [PMID: 36182706 DOI: 10.1016/j.talanta.2022.123966] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2022] [Revised: 09/17/2022] [Accepted: 09/22/2022] [Indexed: 12/13/2022]
Abstract
Organophosphorus pesticides (OPs) are one of the most frequently used pesticides in agriculture, and their residues in environment have caused serious human health and environmental concerns. In this work, we reported a dual-ratiometric electrochemical aptasensor based on carbon nanohorns/anthraquinone-2-carboxylic acid/Au nanoparticles (CNHs/AQ/AuNPs) for simultaneous detection of malathion (MAL) and omethoate (OMT). Here, CNHs/AQ/AuNPs composites were synthesized by a simple room temperature method, and used as a substrate to generate a reference signal (IAQ) and enlarge response signals. Hairpin DNA was then immobilized, offering independent and specific binding sites to further adsorb MB-labelled MAL aptamer (MB-Apt1) and Fc-labelled OMT aptamer (Fc-Apt2). Upon the addition of MAL or OMT, the formation of aptamer-target complex caused the release of MB-Apt1 or Fc-Apt2 from the electrode, resulting in a decrease in IMB or IFc, while IAQ kept unchanged. Based on this principle, the ratiometric signals of IMB/IAQ and IFc/IAQ were used to simultaneously detect MAL and OMT, offering a linear range of 3 pg mL-1 to 3 ng mL-1 for MAL and 10 pg mL-1 to 10 ng mL-1 for OMT, and no significant cross-reactivity existed. By taking advantage of the excellent conductivity and large specific area of CNHs/AQ/AuNPs and the stable two-dimensional structure of hairpin DNA, the aptasensor exhibited high sensitivity, selectivity and reliability. Our work has offered a novel way for simultaneous detection of multiple OPs.
Collapse
Affiliation(s)
- Chengxi Zhu
- School of Electrical and Information Engineering, Jiangsu University of Technology, Changzhou 213001, China.
| | - Xiaohong Liu
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Yuye Li
- Key Laboratory of Modern Agricultural Equipment and Technology, Ministry of Education, School of Agricultural Engineering, Jiangsu University, Zhenjiang 212013, China
| | - Dongmei Yu
- School of Electrical and Information Engineering, Jiangsu University of Technology, Changzhou 213001, China
| | - Qian Gao
- School of Electrical and Information Engineering, Jiangsu University of Technology, Changzhou 213001, China
| | - Lixing Chen
- School of Electrical and Information Engineering, Jiangsu University of Technology, Changzhou 213001, China
| |
Collapse
|
11
|
Wang A, Liu J, Yang J, Yang L. Aptamer affinity-based microextraction in-line coupled to capillary electrophoresis mass spectrometry using a porous layer/nanoparticle -modified open tubular column. Anal Chim Acta 2023; 1239:340750. [PMID: 36628776 DOI: 10.1016/j.aca.2022.340750] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2022] [Revised: 12/20/2022] [Accepted: 12/23/2022] [Indexed: 12/26/2022]
Abstract
An aptamer affinity based microextraction column is developed to be directly in-line coupled to capillary electrophoresis-mass spectrometry (CE-MS) for analyzing mycotoxins in food samples. Single-stranded DNA aptamers for selective recognition of aflatoxin B1 (AFB1) and ochratoxin A (OTA) targets are co-immobilized via covalent bonds on the surface of the inlet end of a capillary, which is pre-modified with three-dimensional porous layer and gold nanoparticles to enhance the specific surface area and loading capacity. The outlet of the capillary is designed as a porous tip to serve as the spray source for injection to the mass spectrometry. All the necessary processes for pretreatment and analysis of a sample are accomplished in one injection, including aptamer affinity-based microextraction, CE separation and MS detection of analytes. AFB1 and OTA are simultaneously determined in a wide linear range with sample consumption of only 1 μL and the limit-of-detection as low as 1 pg/mL. The microextraction column exhibits excellent repeatability and stability, which can be used over 45 runs within a month with CE separation efficiency and only MS intensity slightly decreased. Mycotoxins in three kinds of cereal based infant foods are accurately analyzed using the proposed method. The study provides a robust and universal approach that would have potential applications in a variety of analytical fields based on selective molecular recognition coupling to CE-MS analysis.
Collapse
Affiliation(s)
- Anping Wang
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Department of Chemistry, Northeast Normal University, Changchun, 130024, China
| | - Jianing Liu
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Department of Chemistry, Northeast Normal University, Changchun, 130024, China
| | - Jinlan Yang
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Department of Chemistry, Northeast Normal University, Changchun, 130024, China
| | - Li Yang
- Key Laboratory of Polyoxometalate and Reticular Material Chemistry of Ministry of Education, Key Laboratory of Nanobiosensing and Nanobioanalysis at Universities of Jilin Province, Department of Chemistry, Northeast Normal University, Changchun, 130024, China.
| |
Collapse
|
12
|
Zhu J, Xu W, Yang Y, Kong R, Wang J. ssDNA-C3N4 conjugates-based nanozyme sensor array for discriminating mycotoxins. Mikrochim Acta 2022; 190:6. [PMID: 36471087 DOI: 10.1007/s00604-022-05593-y] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2021] [Accepted: 11/23/2022] [Indexed: 12/12/2022]
Abstract
A nanozyme sensor array based on the ssDNA-distensible C3N4 nanosheet sensor elements for discriminating multiple mycotoxins commonly existing in contaminated cereals has been explored. The sensor array exploited (a) three DNA nonspecific sequences (A40, T40, C40) absorbed on the C3N4 nanosheets as sensor elements catalyzing the oxidation of TMB; (b) the presence of five mycotoxins affected the catalytic activity of three nanozymes with various degrees. The parameter (A0-A) was employed as the signal output to obtain the response patterns for different mycotoxins with the same concentration where A0 and A were the absorption peak values at 650 nm of oxTMB in the absence and presence of target mycotoxins, respectively. After the raw data was subjected to principal component analysis, 3D canonical score plots were obtained. The sensor array was capable of separating five mycotoxins from each other with 100% accuracy even if the concentration of the mycotoxins was as low as 1 nM. Moreover, the array performed well in discriminating the mycotoxin mixtures with different ratios. Importantly, the practicality of this sensor array was demonstrated by discriminating the five mycotoxins spiking in corn-free samples in 3D canonical score plots, validating that the sensor array can act as a flexible detection tool for food safety. A nanozyme sensor array was developed based on the ssDNA-distensible C3N4 NSs sensor elements for discriminating muitiple mycotoxins.
Collapse
Affiliation(s)
- Jing Zhu
- College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu Shandong, 273165, People's Republic of China.
| | - Wenxing Xu
- College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu Shandong, 273165, People's Republic of China
| | - Ye Yang
- College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu Shandong, 273165, People's Republic of China
| | - Rongmei Kong
- College of Chemistry and Chemical Engineering, Qufu Normal University, Qufu Shandong, 273165, People's Republic of China
| | - Junmei Wang
- College of Chemistry and Chemical Engineering, Shangqiu Normal University, Shangqiu, 476000, People's Republic of China.
| |
Collapse
|
13
|
Yang Y, Ren MY, Xu XG, Han Y, Zhao X, Li CH, Zhao ZL. Recent advances in simultaneous detection strategies for multi-mycotoxins in foods. Crit Rev Food Sci Nutr 2022; 64:3932-3960. [PMID: 36330603 DOI: 10.1080/10408398.2022.2137775] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Mycotoxin contamination has become a challenge in the field of food safety testing, given the increasing emphasis on food safety in recent years. Mycotoxins are widely distributed, in heavily polluted areas. Food contamination with these toxins is difficult to prevent and control. Mycotoxins, as are small-molecule toxic metabolites produced by several species belonging to the genera Aspergillus, Fusarium, and Penicillium growing in food. They are considered teratogenic, carcinogenic, and mutagenic to humans and animals. Food systems are often simultaneously contaminated with multiple mycotoxins. Due to the additive or synergistic toxicological effects caused by the co-existence of multiple mycotoxins, their individual detection requires reliable, accurate, and high-throughput techniques. Currently available, methods for the detection of multiple mycotoxins are mainly based on chromatography, spectroscopy (colorimetry, fluorescence, and surface-enhanced Raman scattering), and electrochemistry. This review provides a comprehensive overview of advances in the multiple detection methods of mycotoxins during the recent 5 years. The principles and features of these techniques are described. The practical applications and challenges associated with assays for multiple detection methods of mycotoxins are summarized. The potential for future development and application is discussed in an effort, to provide standards of references for further research.
Collapse
Affiliation(s)
- Ying Yang
- School of Quality and Technical Supervision, Hebei University, Baoding, China
- National & Local Joint Engineering Research Center of Metrology Instrument and System, Hebei University, Baoding, China
- Hebei Key Laboratory of Energy Metering and Safety Testing Technology, Hebei University, Baoding, China
| | - Meng-Yu Ren
- School of Quality and Technical Supervision, Hebei University, Baoding, China
- National & Local Joint Engineering Research Center of Metrology Instrument and System, Hebei University, Baoding, China
- Hebei Key Laboratory of Energy Metering and Safety Testing Technology, Hebei University, Baoding, China
| | - Xiao-Guang Xu
- School of Traditional Chinese Medicine, Hebei University, Baoding, China
| | - Yue Han
- School of Quality and Technical Supervision, Hebei University, Baoding, China
- National & Local Joint Engineering Research Center of Metrology Instrument and System, Hebei University, Baoding, China
- Hebei Key Laboratory of Energy Metering and Safety Testing Technology, Hebei University, Baoding, China
| | - Xin Zhao
- School of Quality and Technical Supervision, Hebei University, Baoding, China
- National & Local Joint Engineering Research Center of Metrology Instrument and System, Hebei University, Baoding, China
- Hebei Key Laboratory of Energy Metering and Safety Testing Technology, Hebei University, Baoding, China
| | - Chun-Hua Li
- School of Quality and Technical Supervision, Hebei University, Baoding, China
- National & Local Joint Engineering Research Center of Metrology Instrument and System, Hebei University, Baoding, China
- Hebei Key Laboratory of Energy Metering and Safety Testing Technology, Hebei University, Baoding, China
| | - Zhi-Lei Zhao
- School of Quality and Technical Supervision, Hebei University, Baoding, China
- National & Local Joint Engineering Research Center of Metrology Instrument and System, Hebei University, Baoding, China
- Hebei Key Laboratory of Energy Metering and Safety Testing Technology, Hebei University, Baoding, China
| |
Collapse
|
14
|
Surface Plasmon Resonance (SPR) biosensor for detection of mycotoxins: A review. J Immunol Methods 2022; 510:113349. [PMID: 36088984 DOI: 10.1016/j.jim.2022.113349] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2022] [Revised: 08/18/2022] [Accepted: 08/30/2022] [Indexed: 12/31/2022]
Abstract
Mycotoxin is one of the most important natural pollutants, which poses a global threat to food safety. However, the pollution of mold in food production is inevitable. The detection technology of mycotoxins in food production is an important means to prevent the damage of mycotoxins, so rapid detection and screening to avoid pollution diffusion is essential. The focus of this review is to update the literature on the detection of mycotoxins by surface plasmon resonance (SPR) technology, rather than just traditional chromatographic methods. As a relatively novel and simple analytical method, SPR has been proved to be fast, sensitive and label-free, and has been widely used in real-time qualitative and quantitative analysis of various pollutants. This paper aims to give a broad overview of the sensors for detection and analysis of several common mycotoxins.
Collapse
|
15
|
Zhao X, Gao J, Song Y, Zhang J, Han Q. Establishment of an Improved ELONA Method for Detecting Fumonisin B 1 Based on Aptamers and Hemin-CDs Conjugates. SENSORS (BASEL, SWITZERLAND) 2022; 22:6714. [PMID: 36081171 PMCID: PMC9460299 DOI: 10.3390/s22176714] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/20/2022] [Revised: 09/02/2022] [Accepted: 09/02/2022] [Indexed: 06/15/2023]
Abstract
Fumonisin B1 (FB1) is a strong mycotoxin that is ubiquitous in agricultural products. The establishment of rapid detection methods is an important means to prevent and control FB1 contamination. In this study, an improved enzyme-linked oligonucleotide assay (ELONA) method was designed and tested to detect the contents of FB1 in maize (corn) samples. F10 modified with biotin was bound to an enzyme label plate that was coated with streptavidin (SA) in advance, and carbon dots (CDs) were used to catalyze the color of tetramethylbenzidine (TMB). The complementary chain of F10 was modified with an amino group and coupled with CDs to obtain conjugates. The sample and conjugates were then added to the enzyme plate coated with F10 (an FB1 aptamer). Upon completion of the color reaction, the absorbance was measured at 450 nm. The LOD of this method was 4.30 ng/mL and the LOQ was 13.03 ng/mL. We observed a linear relationship in the FB1 concentration range of 0-100 ng/mL. The standard curve was y = -0.001482 × x + 0.3463, R2 = 0.9918, and the experimental results could be directly measured visually. The recovery of the maize sample was 97.5-99.23% and 94.54-99.25%, and the total detection time was 1 h.
Collapse
Affiliation(s)
| | | | | | | | - Qinqin Han
- Correspondence: ; Tel.: +86-(0871)-6593-9528
| |
Collapse
|
16
|
Li M, Li DY, Li ZY, Hu R, Yang YH, Yang T. A visual peroxidase mimicking aptasensor based on Pt nanoparticles-loaded on iron metal organic gel for fumonisin B1 analysis in corn meal. Biosens Bioelectron 2022; 209:114241. [DOI: 10.1016/j.bios.2022.114241] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 03/12/2022] [Accepted: 04/01/2022] [Indexed: 01/10/2023]
|
17
|
Detection of fumonisin B1 by aptamer-functionalized magnetic beads and ultra-performance liquid chromatography. Microchem J 2022. [DOI: 10.1016/j.microc.2022.107346] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
|
18
|
Wang Y, Zhang C, Wang J, Knopp D. Recent Progress in Rapid Determination of Mycotoxins Based on Emerging Biorecognition Molecules: A Review. Toxins (Basel) 2022; 14:73. [PMID: 35202100 PMCID: PMC8874725 DOI: 10.3390/toxins14020073] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2021] [Revised: 01/14/2022] [Accepted: 01/15/2022] [Indexed: 12/12/2022] Open
Abstract
Mycotoxins are secondary metabolites produced by fungal species, which pose significant risk to humans and livestock. The mycotoxins which are produced from Aspergillus, Penicillium, and Fusarium are considered most important and therefore regulated in food- and feedstuffs. Analyses are predominantly performed by official laboratory methods in centralized labs by expert technicians. There is an urgent demand for new low-cost, easy-to-use, and portable analytical devices for rapid on-site determination. Most significant advances were realized in the field bioanalytical techniques based on molecular recognition. This review aims to discuss recent progress in the generation of native biomolecules and new bioinspired materials towards mycotoxins for the development of reliable bioreceptor-based analytical methods. After brief presentation of basic knowledge regarding characteristics of most important mycotoxins, the generation, benefits, and limitations of present and emerging biorecognition molecules, such as polyclonal (pAb), monoclonal (mAb), recombinant antibodies (rAb), aptamers, short peptides, and molecularly imprinted polymers (MIPs), are discussed. Hereinafter, the use of binders in different areas of application, including sample preparation, microplate- and tube-based assays, lateral flow devices, and biosensors, is highlighted. Special focus, on a global scale, is placed on commercial availability of single receptor molecules, test-kits, and biosensor platforms using multiplexed bead-based suspension assays and planar biochip arrays. Future outlook is given with special emphasis on new challenges, such as increasing use of rAb based on synthetic and naïve antibody libraries to renounce animal immunization, multiple-analyte test-kits and high-throughput multiplexing, and determination of masked mycotoxins, including stereoisomeric degradation products.
Collapse
Affiliation(s)
- Yanru Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Xianyang 712100, China; (Y.W.); (C.Z.)
| | - Cui Zhang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Xianyang 712100, China; (Y.W.); (C.Z.)
| | - Jianlong Wang
- College of Food Science and Engineering, Northwest A&F University, Yangling, Xianyang 712100, China; (Y.W.); (C.Z.)
| | - Dietmar Knopp
- Chair for Analytical Chemistry and Water Chemistry, Institute of Hydrochemistry, Technische Universitat München, Elisabeth-Winterhalter-Weg 6, D-81377 München, Germany
| |
Collapse
|
19
|
Zhang T, Zhang Y, Li W, Wang L, Jiao Y, Wang Y, Jiang D, Gao X. Occurrence and dietary exposure of heavy metals in marketed vegetables and fruits of Shandong Province, China. Food Sci Nutr 2021; 9:5166-5173. [PMID: 34532025 PMCID: PMC8441287 DOI: 10.1002/fsn3.2485] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2021] [Revised: 06/27/2021] [Accepted: 07/06/2021] [Indexed: 11/26/2022] Open
Abstract
The contamination of heavy metals in vegetables and fruits is a serious threat to food safety and human health. The present study was designed to investigate the occurrence and dietary exposure of lead (Pb), arsenic (As), cadmium (Cd), and mercury (Hg) in vegetables and fruits in Shandong Province, China. Results demonstrated that the mean level of total heavy metals was 30.25 µg/kg. The most frequently found heavy metal was Cd (69.2%) with a mean value of 11.54 µg/kg. The mean exposure values of Pb, As, Cd, and Hg in vegetables were 0.052, 0.045, 0.038, and 2.40 × 10-3 µg/kg bw/day, respectively. Moreover, the calculated hazard quotient (HQ) values of mean levels for these four heavy metals were all less than 1, indicating the health risk of heavy metal exposure caused by vegetable consumption was low. This study has displayed baseline information on heavy metal contamination in vegetables and fruits, which can provide useful data support for the formulation of relevant standards and government management.
Collapse
Affiliation(s)
- Tianran Zhang
- Department of Physical and Chemical InspectionSchool of Public HealthCheeloo College of MedicineShandong UniversityJinanP. R. China
- Department of Physical and Chemical TestingShandong Center for Food Safety Risk AssessmentShandong Center for Disease Control and PreventionJinanP. R. China
| | - Yuan Zhang
- Department of Medical ExaminationShandong Medical CollegeJinanP. R. China
| | - Wei Li
- Department of Physical and Chemical TestingShandong Center for Food Safety Risk AssessmentShandong Center for Disease Control and PreventionJinanP. R. China
| | - Lin Wang
- Department of Physical and Chemical TestingShandong Center for Food Safety Risk AssessmentShandong Center for Disease Control and PreventionJinanP. R. China
| | - Yanni Jiao
- Department of Physical and Chemical TestingShandong Center for Food Safety Risk AssessmentShandong Center for Disease Control and PreventionJinanP. R. China
| | - Yuxin Wang
- Department of Physical and Chemical InspectionSchool of Public HealthCheeloo College of MedicineShandong UniversityJinanP. R. China
| | - Dafeng Jiang
- Department of Physical and Chemical TestingShandong Center for Food Safety Risk AssessmentShandong Center for Disease Control and PreventionJinanP. R. China
| | - Xibao Gao
- Department of Physical and Chemical InspectionSchool of Public HealthCheeloo College of MedicineShandong UniversityJinanP. R. China
| |
Collapse
|
20
|
Mirón-Mérida VA, Gong YY, Goycoolea FM. Aptamer-based detection of fumonisin B1: A critical review. Anal Chim Acta 2021; 1160:338395. [PMID: 33894965 DOI: 10.1016/j.aca.2021.338395] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2021] [Revised: 03/02/2021] [Accepted: 03/05/2021] [Indexed: 01/07/2023]
Abstract
Mycotoxin contamination is a current issue affecting several crops and processed products worldwide. Among the diverse mycotoxin group, fumonisin B1 (FB1) has become a relevant compound because of its adverse effects in the food chain. Conventional analytical methods previously proposed to quantify FB1 comprise LC-MS, HPLC-FLD and ELISA, while novel approaches integrate different sensing platforms and fluorescently labelled agents in combination with antibodies. Nevertheless, such methods could be expensive, time-consuming and require experience. Aptamers (ssDNA) are promising alternatives to overcome some of the drawbacks of conventional analytical methods, their high affinity through specific aptamer-target binding has been exploited in various designs attaining favorable limits of detection (LOD). So far, two aptamers specific to FB1 have been reported, and their modified and shortened sequences have been explored for a successful target quantification. In this critical review spanning the last eight years, we have conducted a systematic comparison based on principal component analysis of the aptamer-based techniques for FB1, compared with chromatographic, immunological and other analytical methods. We have also conducted an in-silico prediction of the folded structure of both aptamers under their reported conditions. The potential of aptasensors for the future development of highly sensitive FB1 testing methods is emphasized.
Collapse
Affiliation(s)
| | - Yun Yun Gong
- School of Food Science and Nutrition, University of Leeds, Leeds, LS2 9JT, United Kingdom.
| | - Francisco M Goycoolea
- School of Food Science and Nutrition, University of Leeds, Leeds, LS2 9JT, United Kingdom.
| |
Collapse
|