1
|
Seghier ML. 7 T and beyond: toward a synergy between fMRI-based presurgical mapping at ultrahigh magnetic fields, AI, and robotic neurosurgery. Eur Radiol Exp 2024; 8:73. [PMID: 38945979 PMCID: PMC11214939 DOI: 10.1186/s41747-024-00472-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2024] [Accepted: 04/22/2024] [Indexed: 07/02/2024] Open
Abstract
Presurgical evaluation with functional magnetic resonance imaging (fMRI) can reduce postsurgical morbidity. Here, we discuss presurgical fMRI mapping at ultra-high magnetic fields (UHF), i.e., ≥ 7 T, in the light of the current growing interest in artificial intelligence (AI) and robot-assisted neurosurgery. The potential of submillimetre fMRI mapping can help better appreciate uncertainty on resection margins, though geometric distortions at UHF might lessen the accuracy of fMRI maps. A useful trade-off for UHF fMRI is to collect data with 1-mm isotropic resolution to ensure high sensitivity and subsequently a low risk of false negatives. Scanning at UHF might yield a revival interest in slow event-related fMRI, thereby offering a richer depiction of the dynamics of fMRI responses. The potential applications of AI concern denoising and artefact removal, generation of super-resolution fMRI maps, and accurate fusion or coregistration between anatomical and fMRI maps. The latter can benefit from the use of T1-weighted echo-planar imaging for better visualization of brain activations. Such AI-augmented fMRI maps would provide high-quality input data to robotic surgery systems, thereby improving the accuracy and reliability of robot-assisted neurosurgery. Ultimately, the advancement in fMRI at UHF would promote clinically useful synergies between fMRI, AI, and robotic neurosurgery.Relevance statement This review highlights the potential synergies between fMRI at UHF, AI, and robotic neurosurgery in improving the accuracy and reliability of fMRI-based presurgical mapping.Key points• Presurgical fMRI mapping at UHF improves spatial resolution and sensitivity.• Slow event-related designs offer a richer depiction of fMRI responses dynamics.• AI can support denoising, artefact removal, and generation of super-resolution fMRI maps.• AI-augmented fMRI maps can provide high-quality input data to robotic surgery systems.
Collapse
Affiliation(s)
- Mohamed L Seghier
- Department of Biomedical Engineering and Biotechnology, Khalifa University of Science and Technology, Abu Dhabi, UAE.
- Healtcare Engineering Innovation Center (HEIC), Khalifa University of Science and Technology, Abu Dhabi, UAE.
| |
Collapse
|
2
|
Rivero-Moreno Y, Echevarria S, Vidal-Valderrama C, Pianetti L, Cordova-Guilarte J, Navarro-Gonzalez J, Acevedo-Rodríguez J, Dorado-Avila G, Osorio-Romero L, Chavez-Campos C, Acero-Alvarracín K. Robotic Surgery: A Comprehensive Review of the Literature and Current Trends. Cureus 2023; 15:e42370. [PMID: 37621804 PMCID: PMC10445506 DOI: 10.7759/cureus.42370] [Citation(s) in RCA: 30] [Impact Index Per Article: 15.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 07/23/2023] [Indexed: 08/26/2023] Open
Abstract
Robotic surgery (RS) is an evolution of minimally invasive surgery that combines medical science, robotics, and engineering. The first robots approved by the Food and Drug Administration (FDA) were the Da Vinci Surgical System and the ZEUS Robotic Surgical System, which have been improving over time. Through the decades, the equipment applied to RS had undergone a wide transformation as a response to the development of new techniques and facilities for the assembly and implementation of the own. RS has revolutionized the field of urology, enabling surgeons to perform complex procedures with greater precision and accuracy, and many other surgical specialties such as gynecology, general surgery, otolaryngology, cardiothoracic surgery, and neurosurgery. Several benefits, such as a better approach to the surgical site, a three-dimensional image that improves depth perception, and smaller scars, enhance range of motion, allowing the surgeon to conduct more complicated surgical operations, and reduced postoperative complications have made robotic-assisted surgery an increasingly popular approach. However, some points like the cost of surgical procedures, equipment-instrument, and maintenance are important aspects to consider. Machine learning will likely have a role to play in surgical training shortly through "automated performance metrics," where algorithms observe and "learn" individual surgeons' techniques, assess performance, and anticipate surgical outcomes with the potential to individualize surgical training and aid decision-making in real time.
Collapse
Affiliation(s)
| | | | | | - Luigi Pianetti
- General Surgery, Universidad Nacional del Litoral, Argentina, ARG
| | | | | | | | | | | | | | | |
Collapse
|
3
|
Silva JB, Busnello CV, Cesarino MR, Xavier LF, Cavazzola LT. Existe espaço para a microcirurgia na cirurgia robótica? Rev Bras Ortop 2022; 57:709-717. [PMID: 36226217 PMCID: PMC9550381 DOI: 10.1055/s-0042-1744496] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Accepted: 02/07/2022] [Indexed: 11/06/2022] Open
Abstract
Robotic surgery opened a new era of minimally-invasive procedures, through its improved precision, elimination of tremors, greater degrees of freedom, and other facilitating aspects. The field of robotic microsurgery showed great growth in recent years in particular, since robotics offers a potentially-ideal configuration to perform the sensitive manipulations required in microsurgery. We conducted a systematic review to assess the benefits of robotic surgery and its contributions to microsurgery, comparing it with other surgical techniques used in patients of all age groups. We assessed 25 articles found in the PubMed and Cochrane databases using the terms '
robotic surgery
' AND
microsurgery
, with a filter for studies published in the last five years, and studies conducted in humans and published in English or Portuguese. We concluded that there is plenty of room for robotic surgery in microsurgery, such as in male infertility procedures, neurological microsurgery, ocular and otological surgeries, and transoral, hepatobiliary, microvascular, plastic and reconstructive surgeries.
Collapse
Affiliation(s)
- Jefferson Braga Silva
- Escola de Medicina, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brasil
- Departamento de Cirurgia da Mão e Microcirurgia Reconstrutiva, Hospital São Lucas, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brasil
| | - Catarina Vellinho Busnello
- Escola de Medicina, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brasil
| | - Matheus Ribeiro Cesarino
- Escola de Medicina, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brasil
| | - Luiza Fernandes Xavier
- Escola de Medicina, Pontifícia Universidade Católica do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brasil
| | - Leandro Totti Cavazzola
- Departamento de Cirurgia da Universidade Federal do Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brasil
| |
Collapse
|
4
|
Udayakumaran S, Krishnadas A, Subash P. Robot-assisted frontofacial correction in very young children with craniofacial dysostosis syndromes: a technical note and early functional outcome. Neurosurg Focus 2022; 52:E16. [PMID: 34973669 DOI: 10.3171/2021.10.focus21515] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2021] [Accepted: 10/19/2021] [Indexed: 11/06/2022]
Abstract
OBJECTIVE In this study, the authors aimed to 1) retrospectively analyze the early functional outcomes in a cohort of very young children with craniofacial dysostoses who underwent robot-assisted frontofacial advancement (RAFFA) or robot-assisted midface distraction (RAMD), and 2) analyze the utility of robotic assistance in improving the accuracy and safety of performing transfacial pin insertion for RAFFA or RAMD. METHODS A retrospective analysis of a cohort of 18 children (age range 1-42 months at presentation), who underwent RAFFA or RAMD from February 2015 to February 2021 in the craniofacial unit at Amrita Institute of Medical Sciences and Research Centre in Kochi, India, was performed. Inclusion criteria were patients who had undergone RAFFA in a single stage or RAMD where the cranial vault had been addressed earlier, had been addressed on follow-up, or had not been addressed and had follow-up of at least 6 months. RESULTS Overall, 18 children with syndromic craniosynostosis underwent LeFort level III midface distraction, with or without RAFFA, from February 2015 to February 2021 at a single center in India. The patients' ages ranged from 6 to 47 months at the time of the procedure. All patients had significant obstructive sleep apnea (OSA), significant ocular issues, and disturbed sleep as determined by the authors' preoperative protocol. Clinically significant intracranial pressure issues were present in 17 patients. None of the patients had injury due to the transfacial pin trajectory such as globe injury, damage to the tooth buds, or the loss of purchase during the active distraction phase. The mean distraction achieved was 23 mm (range 18-30 mm) (n = 16/18). Of the 18 patients, 10 (56%) had an excellent outcome and 6 (33%) had a satisfactory outcome. In all cases, the degree of OSA had significantly reduced after surgery. Eye closure improved in all patients, and complete closure was seen in 11 patients. On follow-up, the functional gain remained in 14 of 16 patients at the final follow-up visit. The distraction results were stable during the follow-up period (mean 36 months [range 6-72 months]). CONCLUSIONS The early RAFFA and RAMD protocols investigated in this study gave a significant functional advantage in very young patients with craniofacial dysostoses. The results have demonstrated the accuracy and safety of robotic assistance in performing transfacial pin insertion for RAFFA or RAMD.
Collapse
Affiliation(s)
- Suhas Udayakumaran
- 1Division of Paediatric Neurosurgery and Craniofacial Surgery, Department of Neurosurgery, Amrita Institute of Medical Sciences and Research Centre, Amrita Viswa Vidyapeetham, Kochi, Kerala; and
| | - Arjun Krishnadas
- 2Division of Craniomaxillofacial Surgery, Amrita Institute of Medical Sciences and Research Centre, Amrita Viswa Vidyapeetham, Kochi, Kerala, India
| | - Pramod Subash
- 2Division of Craniomaxillofacial Surgery, Amrita Institute of Medical Sciences and Research Centre, Amrita Viswa Vidyapeetham, Kochi, Kerala, India
| |
Collapse
|
5
|
Zappa F, Madoglio A, Ferrari M, Mattavelli D, Schreiber A, Taboni S, Ferrari E, Rampinelli V, Belotti F, Piazza C, Fontanella MM, Nicolai P, Doglietto F. Hybrid Robotics for Endoscopic Transnasal Skull Base Surgery: Single-Centre Case Series. Oper Neurosurg (Hagerstown) 2021; 21:426-435. [PMID: 34624091 DOI: 10.1093/ons/opab327] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Accepted: 07/18/2021] [Indexed: 11/13/2022] Open
Abstract
BACKGROUND Only preclinical studies and case reports have described robotic surgery for endoscopic transnasal skull base surgery. OBJECTIVE To evaluate the role of a novel robotic endoscope holder, developed for transsphenoidal surgery. METHODS Patients were prospectively enrolled for 3 mo at the Neurosurgery Unit of Brescia. Endoscope Robot® was used to assist during the sphenoidal phase of the approach, tumor removal, and skull base reconstruction. A Likert scale questionnaire was given to all surgeons after each procedure. Patients who underwent robotic-assisted surgery were matched with nonrobotic ones for pathology and type of procedure. All surgical videos were evaluated during bimanual phases. RESULTS Twenty-one patients underwent robot-assisted, endoscopic transsphenoidal surgery for different pathologies (16 pituitary adenomas, 3 chordomas, 1 craniopharyngioma, 1 pituitary exploration for Cushing disease) for a total of 23 procedures (1 patient underwent 2 endoscopic revisions of a skull base reconstruction). Subjective advantages reported by surgeons included smoothness of movement, image steadiness, and improvement of maneuvers in narrow spaces and with angled endoscopes; as the main limitation, Endoscope Robot® appeared to be relatively heavy during the initial endoscope positioning. A comparative analysis with a historical matched cohort documented similar clinical outcomes, while endoscope lens cleaning and position readjustments were significantly less frequent in robotic procedures. CONCLUSION Although confirmation in larger studies is needed, Endoscope Robot® was a safe and effective tool, especially advantageous in lengthy interventions through deep and narrow corridors.
Collapse
Affiliation(s)
- Francesca Zappa
- Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy
| | - Alba Madoglio
- Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy
| | - Marco Ferrari
- Otorhinolaryngology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy.,Section of Otorhinolaryngology-Head and Neck Surgery, Department of Neurosciences, University of Padua, Padua, Italy
| | - Davide Mattavelli
- Otorhinolaryngology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy
| | - Alberto Schreiber
- Otorhinolaryngology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy
| | - Stefano Taboni
- Otorhinolaryngology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy.,Section of Otorhinolaryngology-Head and Neck Surgery, Department of Neurosciences, University of Padua, Padua, Italy
| | - Erika Ferrari
- Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy
| | - Vittorio Rampinelli
- Otorhinolaryngology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy
| | - Francesco Belotti
- Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy
| | - Cesare Piazza
- Otorhinolaryngology, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy
| | - Marco Maria Fontanella
- Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy
| | - Piero Nicolai
- Section of Otorhinolaryngology-Head and Neck Surgery, Department of Neurosciences, University of Padua, Padua, Italy
| | - Francesco Doglietto
- Neurosurgery, Department of Medical and Surgical Specialties, Radiological Sciences and Public Health, University of Brescia, Brescia, Italy
| |
Collapse
|
6
|
Ball T, González-Martínez J, Zemmar A, Sweid A, Chandra S, VanSickle D, Neimat JS, Jabbour P, Wu C. Robotic Applications in Cranial Neurosurgery: Current and Future. Oper Neurosurg (Hagerstown) 2021; 21:371-379. [PMID: 34192764 DOI: 10.1093/ons/opab217] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Accepted: 05/16/2021] [Indexed: 12/19/2022] Open
Abstract
Robotics applied to cranial surgery is a fast-moving and fascinating field, which is transforming the practice of neurosurgery. With exponential increases in computing power, improvements in connectivity, artificial intelligence, and enhanced precision of accessing target structures, robots are likely to be incorporated into more areas of neurosurgery in the future-making procedures safer and more efficient. Overall, improved efficiency can offset upfront costs and potentially prove cost-effective. In this narrative review, we aim to translate a broad clinical experience into practical information for the incorporation of robotics into neurosurgical practice. We begin with procedures where robotics take the role of a stereotactic frame and guide instruments along a linear trajectory. Next, we discuss robotics in endoscopic surgery, where the robot functions similar to a surgical assistant by holding the endoscope and providing retraction, supplemental lighting, and correlation of the surgical field with navigation. Then, we look at early experience with endovascular robots, where robots carry out tasks of the primary surgeon while the surgeon directs these movements remotely. We briefly discuss a novel microsurgical robot that can perform many of the critical operative steps (with potential for fine motor augmentation) remotely. Finally, we highlight 2 innovative technologies that allow instruments to take nonlinear, predetermined paths to an intracranial destination and allow magnetic control of instruments for real-time adjustment of trajectories. We believe that robots will play an increasingly important role in the future of neurosurgery and aim to cover some of the aspects that this field holds for neurosurgical innovation.
Collapse
Affiliation(s)
- Tyler Ball
- Department of Neurosurgery, University of Louisville, Louisville, Kentucky, USA
| | | | - Ajmal Zemmar
- Department of Neurosurgery, University of Louisville, Louisville, Kentucky, USA.,Department of Neurosurgery, People's Hospital of Zhengzhou University, Henan Provincial People's Hospital, Henan University People's Hospital, Henan University School of Medicine, Zhengzhou, China
| | - Ahmad Sweid
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Sarat Chandra
- Department of Neurosurgery, All India Institute of Medical Science, New Delhi, India
| | | | - Joseph S Neimat
- Department of Neurosurgery, University of Louisville, Louisville, Kentucky, USA
| | - Pascal Jabbour
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| | - Chengyuan Wu
- Department of Neurosurgery, Thomas Jefferson University, Philadelphia, Pennsylvania, USA
| |
Collapse
|
7
|
Lim A, Schonewille A, Forbrigger C, Looi T, Drake J, Diller E. Design and Comparison of Magnetically-Actuated Dexterous Forceps Instruments for Neuroendoscopy. IEEE Trans Biomed Eng 2021; 68:846-856. [PMID: 32746054 DOI: 10.1109/tbme.2020.3007581] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Robot-assisted minimally invasive surgical (MIS) techniques offer improved instrument precision and dexterity, reduced patient trauma and risk, and promise to lessen the skill gap among surgeons. These approaches are common in general surgery, urology, and gynecology. However, MIS techniques remain largely absent for surgical applications within narrow, confined workspaces, such as neuroendoscopy. The limitation stems from a lack of small yet dexterous robotic tools. In this work, we present the first instance of a surgical robot with a direct magnetically-driven end effector capable of being deployed through a standard neuroendoscopic working channel (3.2 mm outer diameter) and operate at the neuroventricular scale. We propose a physical model for the gripping performance of three unique end-effector magnetization profiles and mechanical designs. Rates of blocking force per external magnetic flux density magnitude were 0.309 N/T, 0.880 N/T, and 0.351 N/T for the three designs which matched the physical model's prediction within 14.9% error. The rate of gripper closure per external magnetic flux density had a mean percent error of 11.2% compared to the model. The robot's performance was qualitatively evaluated during a pineal region tumor resection on a tumor analogue in a silicone brain phantom. These results suggest that wireless magnetic actuation may be feasible for dexterously manipulating tissue during minimally invasive neurosurgical procedures.
Collapse
|
8
|
Xu C, Lin L, Aung ZM, Chen X, Sun M, Chai G, Xie L. A Preliminary Study on Animal Experiments of Robot-Assisted Craniotomy. World Neurosurg 2021; 149:e748-e757. [PMID: 33540095 DOI: 10.1016/j.wneu.2021.01.108] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2020] [Revised: 01/21/2021] [Accepted: 01/22/2021] [Indexed: 10/22/2022]
Abstract
BACKGROUND Traditional craniotomy relies on the surgeon's experience and can be complicated owing to excessive skull bone removal, undesirable brain tissue penetration, or severe bleeding. For craniotomy, we developed a robot system based on intraoperative cone-beam computed tomography image guidance and human-robot cooperative interaction, aiming to improve the safety and accuracy of surgery and reduce the labor-intensiveness of the procedure. METHODS Intraoperative cone-beam computed tomography image guidance was adopt to improve the accuracy in our experiment. Craniotomy was performed using an interactive method based on human-robot collaboration, which could achieve a natural interactive method in accordance with surgeons' operating habits. The frequency-based method of contact distinction and the method of torque estimation were used to improve the safety of the designed robot. RESULTS An animal experiment was conducted to verify the effectiveness of the robot system. During the drilling process, the position error was 0.92 ± 0.17 mm (upper surface) and 0.97 ± 0.11 mm (lower surface), and the angle error was 3.37 ± 1.43°. During the milling process, the position error was 1.06 ± 0.13 mm (upper surface) and 1.09 ± 0.09 mm (lower surface). The results showed that the system had sufficient precision and could better complete craniotomy with human-robot collaboration. In addition, with the feedback of multisensor information, the robot system could achieve a sufficient level of safety. CONCLUSIONS The robot system can achieve accurate positioning and safe user-friendly human-robot interaction, which solves problems encountered in the drilling and milling of craniotomy, meets clinical needs, and provides a new method for robot-assisted craniotomy.
Collapse
Affiliation(s)
- Cheng Xu
- Institute of Forming Technology & Equipment, Shanghai, China
| | - Li Lin
- Institute of Forming Technology & Equipment, Shanghai, China
| | - Zin Mar Aung
- Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Xiaojun Chen
- Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Mengzhe Sun
- Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Gang Chai
- Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China
| | - Le Xie
- Institute of Forming Technology & Equipment, Shanghai, China; Institute of Medical Robotics, Shanghai Jiao Tong University, Shanghai, China.
| |
Collapse
|
9
|
Faraji AH, Remick M, Abel TJ. Contributions of Robotics to the Safety and Efficacy of Invasive Monitoring With Stereoelectroencephalography. Front Neurol 2020; 11:570010. [PMID: 33391145 PMCID: PMC7772229 DOI: 10.3389/fneur.2020.570010] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2020] [Accepted: 11/09/2020] [Indexed: 12/19/2022] Open
Abstract
The purpose of this review is to provide a discussion of the history and utility of robotics in invasive monitoring for epilepsy surgery using stereoelectroencephalography (sEEG). The authors conducted a literature review of available sources to describe how the advent of surgical robotics has improved the efficacy and ease of performing sEEG surgery. The sEEG method integrates anatomic, electrographic, and clinical information to test hypotheses regarding the localization of the epileptogenic zone (EZ) and has been used in Europe since the 1950s. One of the primary benefits of robot-assisted sEEG implantation techniques is the ability to seamlessly transition between both orthogonal and oblique trajectory types using a single technique. Based on available information, it is our view that, when applied appropriately, robotic sEEG can have a low rate of complications and many advantages over both non-robotic sEEG implantation and traditional craniotomy-based invasive monitoring methods.
Collapse
Affiliation(s)
- Amir H Faraji
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX, United States.,Department of Neurological Surgery, University of Pittsburgh, Pittsburgh, PA, United States
| | - Madison Remick
- Department of Neurological Surgery, University of Pittsburgh, Pittsburgh, PA, United States
| | - Taylor J Abel
- Department of Neurological Surgery, University of Pittsburgh, Pittsburgh, PA, United States.,Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA, United States
| |
Collapse
|
10
|
Picard F, Deakin AH, Riches PE, Deep K, Baines J. Computer assisted orthopaedic surgery: Past, present and future. Med Eng Phys 2020; 72:55-65. [PMID: 31554577 DOI: 10.1016/j.medengphy.2019.08.005] [Citation(s) in RCA: 33] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2019] [Accepted: 08/23/2019] [Indexed: 12/19/2022]
Abstract
Computer technology is ubiquitous and relied upon in virtually all professional activities including neurosurgery, which is why it is surprising that it is not the case for orthopaedic surgery with fewer than 5% of surgeons using available computer technology in their procedures. In this review, we explore the evolution and background of Computer Assisted Orthopaedic Surgery (CAOS), delving into the basic principles behind the technology and the changes in the discussion on the subject throughout the years and the impact these discussions had on the field. We found evidence that industry had an important role in driving the discussion at least in knee arthroplasty-a leading field of CAOS-with the ratio between patents and publications increased from approximately 1:10 in 2004 to almost 1:3 in 2014. The adoption of CAOS is largely restrained by economics and ergonomics with sceptics challenging the accuracy and precision of navigation during the early years of CAOS moving to patient functional improvements and long term survivorship. Nevertheless, the future of CAOS remains positive with the prospect of new technologies such as improvements in image-guided surgery, enhanced navigation systems, robotics and artificial intelligence.
Collapse
Affiliation(s)
- Frederic Picard
- Golden Jubilee National Hospital, Agamemnon Street, Clydebank, G81 4DY, UK; Department of Biomedical Engineering, University of Strathclyde, Wolfson Centre, 106 Rottenrow, Glasgow, G4 0NW, UK.
| | | | - Philip E Riches
- Department of Biomedical Engineering, University of Strathclyde, Wolfson Centre, 106 Rottenrow, Glasgow, G4 0NW, UK
| | - Kamal Deep
- Golden Jubilee National Hospital, Agamemnon Street, Clydebank, G81 4DY, UK
| | - Joseph Baines
- Golden Jubilee National Hospital, Agamemnon Street, Clydebank, G81 4DY, UK
| |
Collapse
|
11
|
Kim LH, Feng AY, Ho AL, Parker JJ, Kumar KK, Chen KS, Grant GA, Henderson JM, Halpern CH. Robot-assisted versus manual navigated stereoelectroencephalography in adult medically-refractory epilepsy patients. Epilepsy Res 2019; 159:106253. [PMID: 31855826 DOI: 10.1016/j.eplepsyres.2019.106253] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2019] [Revised: 10/14/2019] [Accepted: 12/07/2019] [Indexed: 10/25/2022]
Abstract
OBJECTIVE Stereoelectroencephalography (SEEG) has experienced a recent growth in adoption for epileptogenic zone (EZ) localization. Advances in robotics have the potential to improve the efficiency and safety of this intracranial seizure monitoring method. We present our institutional experience employing robot-assisted SEEG and compare its operative efficiency, seizure reduction outcomes, and direct hospital costs with SEEG performed without robotic assistance using navigated stereotaxy. METHODS We retrospectively identified 50 consecutive adult SEEG cases at our institution in this IRB-approved study, of which 25 were navigated with image guidance (hereafter referred to as "navigated") (02/2014-10/2016) and 25 were robot-assisted (09/2016-12/2017). A thorough review of medical/surgical history and operative records with imaging and trajectory plans was done for each patient. Direct inpatient costs related to each technique were compared. RESULTS Most common seizure etiologies for patients undergoing navigated and robot-assisted SEEG included non-lesional and benign temporal lesions. Despite having a higher mean number of leads-per-patient (10.2 ± 3.5 versus 7.2 ± 2.6, P = 0.002), robot-assisted cases had a significantly shorter mean operative time than navigated cases (125.5±48.5 versus 173.4±84.3 min, P = 0.02). Comparison of robot-assisted cases over the study interval revealed no significant difference in mean operative time (136.4±51.4 min for the first ten cases versus 109.9±75.8 min for the last ten cases, P = 0.25) and estimated operative time-per-lead (13.4±6.0 min for the first ten cases versus 12.9±7.7 min for the last ten cases, P = 0.86). The mean depth, radial, target, and entry point errors for robot-assisted cases were 2.12±1.89, 1.66±1.58, 3.05±2.02 mm, and 1.39 ± 0.75 mm, respectively. The two techniques resulted in equivalent EZ localization rate (navigated 88 %, robot-assisted 96 %, P = 0.30). Common types of epilepsy surgery performed consisted of implantation of responsive neurostimulation (RNS) device (56 %), resection (19.1 %), and laser ablation (23.8 %) for navigated SEEG. For robot-assisted SEEG, either RNS implantation (68.2 %) or laser ablation (22.7 %) were performed or offered. A majority of navigated and robot-assisted patients who underwent epilepsy surgery achieved either Engel Class I (navigated 36.8 %, robot-assisted 31.6 %) or II (navigated 36.8 %, robot-assisted 15.8 %) outcome with no significant difference between the groups (P = 0.14). Direct hospital cost for robot-assisted SEEG was 10 % higher than non-robotic cases. CONCLUSION This single-institutional study suggests that robotic assistance can enhance efficiency of SEEG without compromising safety or precision when compared to image guidance only. Adoption of this technique with uniform safety and efficacy over a short period of time is feasible with favorable epilepsy outcomes.
Collapse
Affiliation(s)
- Lily H Kim
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Austin Y Feng
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Allen L Ho
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Jonathon J Parker
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Kevin K Kumar
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Kevin S Chen
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Gerald A Grant
- Department of Neurosurgery, Stanford University School of Medicine, United States; Division of Pediatric Neurosurgery, Lucile Packard Children's Hospital Stanford, United States
| | - Jaimie M Henderson
- Department of Neurosurgery, Stanford University School of Medicine, United States
| | - Casey H Halpern
- Division of Pediatric Neurosurgery, Lucile Packard Children's Hospital Stanford, United States.
| |
Collapse
|
12
|
Sayari AJ, Pardo C, Basques BA, Colman MW. Review of robotic-assisted surgery: what the future looks like through a spine oncology lens. ANNALS OF TRANSLATIONAL MEDICINE 2019; 7:224. [PMID: 31297389 DOI: 10.21037/atm.2019.04.69] [Citation(s) in RCA: 29] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Recent advancements in medical technology have led to the emergence of robotic-assisted surgery with the hope of creating a safer and more efficient surgical environment for the patient and surgical team. Spine surgery and spine tumor surgery involve challenging anatomy and demand highly precise surgical maneuvers, creating an important niche for robotic systems. While still in its infancy, robotics in spine surgery have proven successful in pedicle screw placement. Similarly, robotics has begun to be used for accurate resections and surgical planning in tumor surgery. As future studies are published and robotics systems continue to evolve, we can expect more tactile haptic feedback and implementation of useful instruments to improve preoperative planning, resection guidance, and reconstruction during spine tumor surgery.
Collapse
Affiliation(s)
- Arash J Sayari
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Coralie Pardo
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Bryce A Basques
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Matthew W Colman
- Department of Orthopaedic Surgery, Rush University Medical Center, Chicago, IL, USA
| |
Collapse
|
13
|
Candela S, Vanegas MI, Darling A, Ortigoza-Escobar JD, Alamar M, Muchart J, Climent A, Ferrer E, Rumià J, Pérez-Dueñas B. Frameless robot-assisted pallidal deep brain stimulation surgery in pediatric patients with movement disorders: precision and short-term clinical results. J Neurosurg Pediatr 2018; 22:416-425. [PMID: 30028274 DOI: 10.3171/2018.5.peds1814] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
OBJECTIVE The purpose of this study was to verify the safety and accuracy of the Neuromate stereotactic robot for use in deep brain stimulation (DBS) electrode implantation for the treatment of hyperkinetic movement disorders in childhood and describe the authors' initial clinical results. METHODS A prospective evaluation of pediatric patients with dystonia and other hyperkinetic movement disorders was carried out during the 1st year after the start-up of a pediatric DBS unit in Barcelona. Electrodes were implanted bilaterally in the globus pallidus internus (GPi) using the Neuromate robot without the stereotactic frame. The authors calculated the distances between the electrodes and their respective planned trajectories, merging the postoperative CT with the preoperative plan using VoXim software. Clinical outcome was monitored using validated scales for dystonia and myoclonus preoperatively and at 1 month and 6 months postoperatively and by means of a quality-of-life questionnaire for children, administered before surgery and at 6 months' follow-up. We also recorded complications derived from the implantation technique, "hardware," and stimulation. RESULTS Six patients aged 7 to 16 years and diagnosed with isolated dystonia ( DYT1 negative) (3 patients), choreo-dystonia related to PDE2A mutation (1 patient), or myoclonus-dystonia syndrome SGCE mutations (2 patients) were evaluated during a period of 6 to 19 months. The average accuracy in the placement of the electrodes was 1.24 mm at the target point. At the 6-month follow-up, patients showed an improvement in the motor (65%) and functional (48%) components of the Burke-Fahn-Marsden Dystonia Rating Scale. Patients with myoclonus and SGCE mutations also showed an improvement in action myoclonus (95%-100%) and in functional tests (50%-75%) according to the Unified Motor-Rating Scale. The Neuro-QOL score revealed inconsistent results, with improvement in motor function and social relationships but worsening in anxiety, cognitive function, and pain. The only surgical complication was medial displacement of the first electrode, which limited intensity of stimulation in the lower contacts, in one case. CONCLUSIONS The Neuromate stereotactic robot is an accurate and safe tool for the placement of GPi electrodes in children with hyperkinetic movement disorders.
Collapse
Affiliation(s)
- Santiago Candela
- Departments of1Neurosurgery.,6Pediatric Movement Disorders Unit, Sant Joan de Déu Barcelona Children's Hospital, Universitat de Barcelona
| | - María Isabel Vanegas
- 2Neuropediatrics, and.,6Pediatric Movement Disorders Unit, Sant Joan de Déu Barcelona Children's Hospital, Universitat de Barcelona.,7Vall d'Hebron Research Institute (VHIR), Universitat Autònoma de Barcelona, Barcelona, Catalonia, Spain
| | - Alejandra Darling
- 2Neuropediatrics, and.,6Pediatric Movement Disorders Unit, Sant Joan de Déu Barcelona Children's Hospital, Universitat de Barcelona
| | - Juan Darío Ortigoza-Escobar
- 2Neuropediatrics, and.,6Pediatric Movement Disorders Unit, Sant Joan de Déu Barcelona Children's Hospital, Universitat de Barcelona
| | - Mariana Alamar
- Departments of1Neurosurgery.,6Pediatric Movement Disorders Unit, Sant Joan de Déu Barcelona Children's Hospital, Universitat de Barcelona
| | - Jordi Muchart
- 3Diagnostic Imaging.,6Pediatric Movement Disorders Unit, Sant Joan de Déu Barcelona Children's Hospital, Universitat de Barcelona
| | - Alejandra Climent
- Departments of1Neurosurgery.,2Neuropediatrics, and.,4Intraoperative Neurophysiology Unit, and.,6Pediatric Movement Disorders Unit, Sant Joan de Déu Barcelona Children's Hospital, Universitat de Barcelona
| | - Enrique Ferrer
- Departments of1Neurosurgery.,5Department of Neurosurgery, Hospital Clinic de Barcelona, Universitat de Barcelona; and.,6Pediatric Movement Disorders Unit, Sant Joan de Déu Barcelona Children's Hospital, Universitat de Barcelona
| | - Jordi Rumià
- Departments of1Neurosurgery.,5Department of Neurosurgery, Hospital Clinic de Barcelona, Universitat de Barcelona; and.,6Pediatric Movement Disorders Unit, Sant Joan de Déu Barcelona Children's Hospital, Universitat de Barcelona
| | - Belén Pérez-Dueñas
- 2Neuropediatrics, and.,6Pediatric Movement Disorders Unit, Sant Joan de Déu Barcelona Children's Hospital, Universitat de Barcelona.,7Vall d'Hebron Research Institute (VHIR), Universitat Autònoma de Barcelona, Barcelona, Catalonia, Spain
| |
Collapse
|
14
|
Ross WA, Hill WM, Hoang KB, Laarakker AS, Mann BP, Codd PJ. Automating neurosurgical tumor resection surgery: Volumetric laser ablation of cadaveric porcine brain with integrated surface mapping. Lasers Surg Med 2018; 50:1017-1024. [DOI: 10.1002/lsm.23000] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 06/21/2018] [Indexed: 11/08/2022]
Affiliation(s)
- Weston A. Ross
- Department of Mechanical Engineering and Materials Science; Duke University; Durham North Carolina
| | - Westin M. Hill
- Department of Mechanical Engineering and Materials Science; Duke University; Durham North Carolina
| | - Kimberly B. Hoang
- Department of Neurosurgery; University of Colorado Denver; Aurora Colorado
| | - Avra S. Laarakker
- Department of Neurosurgery; University of Colorado Denver; Aurora Colorado
| | - Brian P. Mann
- Department of Mechanical Engineering and Materials Science; Duke University; Durham North Carolina
| | - Patrick J. Codd
- Department of Neurosurgery; Duke University School of Medicine; Durham North Carolina
| |
Collapse
|
15
|
Amirabdollahian F, Livatino S, Vahedi B, Gudipati R, Sheen P, Gawrie-Mohan S, Vasdev N. Prevalence of haptic feedback in robot-mediated surgery: a systematic review of literature. J Robot Surg 2017; 12:11-25. [PMID: 29196867 DOI: 10.1007/s11701-017-0763-4] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2017] [Accepted: 11/07/2017] [Indexed: 01/27/2023]
Abstract
With the successful uptake and inclusion of robotic systems in minimally invasive surgery and with the increasing application of robotic surgery (RS) in numerous surgical specialities worldwide, there is now a need to develop and enhance the technology further. One such improvement is the implementation and amalgamation of haptic feedback technology into RS which will permit the operating surgeon on the console to receive haptic information on the type of tissue being operated on. The main advantage of using this is to allow the operating surgeon to feel and control the amount of force applied to different tissues during surgery thus minimising the risk of tissue damage due to both the direct and indirect effects of excessive tissue force or tension being applied during RS. We performed a two-rater systematic review to identify the latest developments and potential avenues of improving technology in the application and implementation of haptic feedback technology to the operating surgeon on the console during RS. This review provides a summary of technological enhancements in RS, considering different stages of work, from proof of concept to cadaver tissue testing, surgery in animals, and finally real implementation in surgical practice. We identify that at the time of this review, while there is a unanimous agreement regarding need for haptic and tactile feedback, there are no solutions or products available that address this need. There is a scope and need for new developments in haptic augmentation for robot-mediated surgery with the aim of improving patient care and robotic surgical technology further.
Collapse
Affiliation(s)
| | - Salvatore Livatino
- School of Engineering, University of Hertfordshire, Hatfield, AL10 9AB, UK
| | - Behrad Vahedi
- School of Engineering, University of Hertfordshire, Hatfield, AL10 9AB, UK
| | - Radhika Gudipati
- School of Computer Science, University of Hertfordshire, Hatfield, AL10 9AB, UK
| | - Patrick Sheen
- School of Engineering, University of Hertfordshire, Hatfield, AL10 9AB, UK
| | | | - Nikhil Vasdev
- Department of Urology, Hertfordshire and Bedfordshire Urological Cancer Centre, Lister Hospital, Stevenage, SG1 4AB, UK.,School of Life and Medical Sciences, University of Hertfordshire, Hatfield, Hertfordshire, AL10 9AB, UK
| |
Collapse
|
16
|
Menaker SA, Shah SS, Snelling BM, Sur S, Starke RM, Peterson EC. Current applications and future perspectives of robotics in cerebrovascular and endovascular neurosurgery. J Neurointerv Surg 2017; 10:78-82. [DOI: 10.1136/neurintsurg-2017-013284] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2017] [Revised: 07/25/2017] [Accepted: 07/26/2017] [Indexed: 11/04/2022]
Abstract
Advances in robotic medicine have been adopted by various surgical subspecialties as the benefits of this technology become more readily apparent: precision in narrow operative windows, tremor controlled movements, and modestly improved outcomes, among others. Vascular neurosurgery, in particular, remains open to newer and more cutting edge treatment options for complex pathologies, and robotics may be on the horizon for such advances. We seek to provide a broad overview of these innovations in vascular neurosurgery for both practitioners well acquainted with robotics and those seeking to become more familiar. Technologies under development for cerebrovascular and endovascular neurosurgery include robot assisted angiography, guided operative microscopes, coil insertion systems, and endoscopic clipping devices. Additionally, robotic systems in the fields of interventional cardiology and radiology have potential applications to endovascular neurosurgery but require proper modifications to navigate complex intracerebral vasculature. Robotic technology is not without drawbacks, as broad implementation may lead to increased cost, training time, and potential delays in emergency situations. Further cultivation of current multidisciplinary technologies and investment into newer systems is necessary before robotics can make a sizable impact in clinical practice.
Collapse
|
17
|
De Benedictis A, Trezza A, Carai A, Genovese E, Procaccini E, Messina R, Randi F, Cossu S, Esposito G, Palma P, Amante P, Rizzi M, Marras CE. Robot-assisted procedures in pediatric neurosurgery. Neurosurg Focus 2017; 42:E7. [DOI: 10.3171/2017.2.focus16579] [Citation(s) in RCA: 104] [Impact Index Per Article: 13.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVEDuring the last 3 decades, robotic technology has rapidly spread across several surgical fields due to the continuous evolution of its versatility, stability, dexterity, and haptic properties. Neurosurgery pioneered the development of robotics, with the aim of improving the quality of several procedures requiring a high degree of accuracy and safety. Moreover, robot-guided approaches are of special interest in pediatric patients, who often have altered anatomy and challenging relationships between the diseased and eloquent structures. Nevertheless, the use of robots has been rarely reported in children. In this work, the authors describe their experience using the ROSA device (Robotized Stereotactic Assistant) in the neurosurgical management of a pediatric population.METHODSBetween 2011 and 2016, 116 children underwent ROSA-assisted procedures for a variety of diseases (epilepsy, brain tumors, intra- or extraventricular and tumor cysts, obstructive hydrocephalus, and movement and behavioral disorders). Each patient received accurate preoperative planning of optimal trajectories, intraoperative frameless registration, surgical treatment using specific instruments held by the robotic arm, and postoperative CT or MR imaging.RESULTSThe authors performed 128 consecutive surgeries, including implantation of 386 electrodes for stereo-electroencephalography (36 procedures), neuroendoscopy (42 procedures), stereotactic biopsy (26 procedures), pallidotomy (12 procedures), shunt placement (6 procedures), deep brain stimulation procedures (3 procedures), and stereotactic cyst aspiration (3 procedures). For each procedure, the authors analyzed and discussed accuracy, timing, and complications.CONCLUSIONSTo the best their knowledge, the authors present the largest reported series of pediatric neurosurgical cases assisted by robotic support. The ROSA system provided improved safety and feasibility of minimally invasive approaches, thus optimizing the surgical result, while minimizing postoperative morbidity.
Collapse
Affiliation(s)
| | - Andrea Trezza
- 1Department of Neuroscience and Neurosurgical Unit and
- 2Neurosurgery, Department of Surgery and Translational Medicine, Milan Center for Neuroscience, University of Milano-Bicocca, San Gerardo Hospital, Monza
| | - Andrea Carai
- 1Department of Neuroscience and Neurosurgical Unit and
| | - Elisabetta Genovese
- 3Enterprise Risk Management, Medical Physics Department, Bambino Gesù Children’s Hospital, IRCCS, Rome
| | | | | | - Franco Randi
- 1Department of Neuroscience and Neurosurgical Unit and
| | - Silvia Cossu
- 1Department of Neuroscience and Neurosurgical Unit and
| | | | - Paolo Palma
- 1Department of Neuroscience and Neurosurgical Unit and
| | | | - Michele Rizzi
- 4“Claudio Munari” Center for Epilepsy Surgery, Niguarda Hospital, Milan; and
- 5Department of Neuroscience, University of Parma, Italy
| | | |
Collapse
|
18
|
|
19
|
Abstract
SUMMARYIn this paper, we study the kinematic effects of number of legs in 6-DOF UPS parallel manipulators. A group of 3-, 4-, and 6-legged mechanisms are evaluated in terms of the kinematic performance indices, workspace, singular configurations, and forward kinematic solutions. Results show that the optimum number of legs varies due to priorities in kinematic measures in different applications. The non-symmetric Wide-Open mechanism enjoys the largest workspace, while the well-known Gough–Stewart (3–3) platform retains the highest dexterity. Especially, the redundantly actuated 4-legged mechanism has several important advantages over its non-redundant counterparts and different architectures of Gough–Stewart platform. It has dramatically less singular configurations, a higher manipulability, and at the same time less sensitivity. It is also shown that the forward kinematic problem has 40, 16, and 1 solution(s), respectively for the 6-, 3-, and the 4-legged mechanisms. Superior capabilities of the 4-legged mechanism make it a perfect candidate to be used in more challenging 6-DOF applications in assembly, manufacturing, biomedical, and space technologies.
Collapse
|
20
|
Ueda H, Suzuki R, Nakazawa A, Kurose Y, Marinho MM, Shono N, Nakatomi H, Saito N, Watanabe E, Morita A, Harada K, Sugita N, Mitsuishi M. Toward Autonomous Collision Avoidance for Robotic Neurosurgery in Deep and Narrow Spaces in the Brain. ACTA ACUST UNITED AC 2017. [DOI: 10.1016/j.procir.2017.04.027] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
21
|
Seung S, Choi H, Jang J, Kim YS, Park JO, Park S, Ko SY. Virtual wall-based haptic-guided teleoperated surgical robotic system for single-port brain tumor removal surgery. Proc Inst Mech Eng H 2016; 231:3-19. [PMID: 27856790 DOI: 10.1177/0954411916676218] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
This article presents a haptic-guided teleoperation for a tumor removal surgical robotic system, so-called a SIROMAN system. The system was developed in our previous work to make it possible to access tumor tissue, even those that seat deeply inside the brain, and to remove the tissue with full maneuverability. For a safe and accurate operation to remove only tumor tissue completely while minimizing damage to the normal tissue, a virtual wall-based haptic guidance together with a medical image-guided control is proposed and developed. The virtual wall is extracted from preoperative medical images, and the robot is controlled to restrict its motion within the virtual wall using haptic feedback. Coordinate transformation between sub-systems, a collision detection algorithm, and a haptic-guided teleoperation using a virtual wall are described in the context of using SIROMAN. A series of experiments using a simplified virtual wall are performed to evaluate the performance of virtual wall-based haptic-guided teleoperation. With haptic guidance, the accuracy of the robotic manipulator's trajectory is improved by 57% compared to one without. The tissue removal performance is also improved by 21% ( p < 0.05). The experiments show that virtual wall-based haptic guidance provides safer and more accurate tissue removal for single-port brain surgery.
Collapse
Affiliation(s)
- Sungmin Seung
- 1 Department of Mechanical Engineering, Chonnam National University, Gwangju, Korea
| | - Hongseok Choi
- 1 Department of Mechanical Engineering, Chonnam National University, Gwangju, Korea
| | - Jongseong Jang
- 2 Institute of Innovative Surgical Technology, Hanyang University, Seoul, Korea
| | - Young Soo Kim
- 3 Department of Neurosurgery, School of Medicine, Hanyang University, Seoul, Korea
| | - Jong-Oh Park
- 1 Department of Mechanical Engineering, Chonnam National University, Gwangju, Korea.,4 Robot Research Initiative, Chonnam National University, Gwangju, Korea
| | - Sukho Park
- 1 Department of Mechanical Engineering, Chonnam National University, Gwangju, Korea.,4 Robot Research Initiative, Chonnam National University, Gwangju, Korea
| | - Seong Young Ko
- 1 Department of Mechanical Engineering, Chonnam National University, Gwangju, Korea.,4 Robot Research Initiative, Chonnam National University, Gwangju, Korea
| |
Collapse
|
22
|
Experimental new automatic tools for robotic stereotactic neurosurgery: towards “no hands” procedure of leads implantation into a brain target. J Neural Transm (Vienna) 2016; 123:737-750. [DOI: 10.1007/s00702-016-1575-9] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2016] [Accepted: 05/10/2016] [Indexed: 11/30/2022]
|
23
|
González-Martínez J, Bulacio J, Thompson S, Gale J, Smithason S, Najm I, Bingaman W. Technique, Results, and Complications Related to Robot-Assisted Stereoelectroencephalography. Neurosurgery 2015; 78:169-80. [DOI: 10.1227/neu.0000000000001034] [Citation(s) in RCA: 209] [Impact Index Per Article: 20.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022] Open
Abstract
ABSTRACT
BACKGROUND:
Robot-assisted stereoelectroencephalography (SEEG) may represent a simplified, precise, and safe alternative to the more traditional SEEG techniques.
OBJECTIVE:
To report our clinical experience with robotic SEEG implantation and to define its utility in the management of patients with medically refractory epilepsy.
METHODS:
The prospective observational analyses included all patients with medically refractory focal epilepsy who underwent robot-assisted stereotactic placement of depth electrodes for extraoperative brain monitoring between November 2009 and May 2013. Technical nuances of the robotic implantation technique are presented, as well as an analysis of demographics, time of planning and procedure, seizure outcome, in vivo accuracy, and procedure-related complications.
RESULTS:
One hundred patients underwent 101 robot-assisted SEEG procedures. Their mean age was 33.2 years. In total, 1245 depth electrodes were implanted. On average, 12.5 electrodes were implanted per patient. The time of implantation planning was 30 minutes on average (range, 15-60 minutes). The average operative time was 130 minutes (range, 45-160 minutes). In vivo accuracy (calculated in 500 trajectories) demonstrated a median entry point error of 1.2 mm (interquartile range, 0.78-1.83 mm) and a median target point error of 1.7 mm (interquartile range, 1.20-2.30 mm). Of the group of patients who underwent resective surgery (68 patients), 45 (66.2%) gained seizure freedom status. Mean follow-up was 18 months. The total complication rate was 4%.
CONCLUSION:
The robotic SEEG technique and method were demonstrated to be safe, accurate, and efficient in anatomically defining the epileptogenic zone and subsequently promoting sustained seizure freedom status in patients with difficult-to-localize seizures.
Collapse
Affiliation(s)
- Jorge González-Martínez
- Epilepsy Center and Neurological Institute, Cleveland Clinic, Cleveland, Ohio
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| | - Juan Bulacio
- Epilepsy Center and Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| | - Susan Thompson
- Epilepsy Center and Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| | - John Gale
- Epilepsy Center and Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| | - Saksith Smithason
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| | - Imad Najm
- Epilepsy Center and Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| | - William Bingaman
- Epilepsy Center and Neurological Institute, Cleveland Clinic, Cleveland, Ohio
- Department of Neurosurgery, Neurological Institute, Cleveland Clinic, Cleveland, Ohio
| |
Collapse
|
24
|
Ho M, Kim Y, Cheng SS, Gullapalli R, Desai JP. Design, development, and evaluation of an MRI-guided SMA spring-actuated neurosurgical robot. Int J Rob Res 2015; 34:1147-1163. [PMID: 26622075 PMCID: PMC4662428 DOI: 10.1177/0278364915579069] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In this paper, we present our work on the development of a magnetic resonance imaging (MRI)-compatible Minimally Invasive Neurosurgical Intracranial Robot (MINIR) comprising of shape memory alloy (SMA) spring actuators and tendon-sheath mechanism. We present the detailed modeling and analysis along with experimental results of the characterization of SMA spring actuators. Furthermore, to demonstrate image-feedback control, we used the images obtained from a camera to control the motion of the robot so that eventually continuous MR images could be used in the future to control the robot motion. Since the image tracking algorithm may fail in some situations, we also developed a temperature feedback control scheme which served as a backup controller for the robot. Experimental results demonstrated that both image feedback and temperature feedback can be used to control the motion of MINIR. A series of MRI compatibility tests were performed on the robot and the experimental results demonstrated that the robot is MRI compatible and no significant visual image distortion was observed in the MR images during robot operation.
Collapse
Affiliation(s)
- Mingyen Ho
- Robotics, Automation, and Medical Systems (RAMS) Laboratory, Department of Mechanical Engineering, University of Maryland, College Park, MD, USA
| | - Yeongjin Kim
- Robotics, Automation, and Medical Systems (RAMS) Laboratory, Department of Mechanical Engineering, University of Maryland, College Park, MD, USA
| | - Shing Shin Cheng
- Robotics, Automation, and Medical Systems (RAMS) Laboratory, Department of Mechanical Engineering, University of Maryland, College Park, MD, USA
| | - Rao Gullapalli
- University of Maryland School of Medicine, Baltimore, MD, USA
| | - Jaydev P Desai
- Robotics, Automation, and Medical Systems (RAMS) Laboratory, Department of Mechanical Engineering, University of Maryland, College Park, MD, USA
| |
Collapse
|
25
|
von Langsdorff D, Paquis P, Fontaine D. In vivo measurement of the frame-based application accuracy of the Neuromate neurosurgical robot. J Neurosurg 2015; 122:191-4. [DOI: 10.3171/2014.9.jns14256] [Citation(s) in RCA: 65] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT
The application accuracy of the Neuromate neurosurgical robot has been validated in vitro but has not been evaluated in vivo for deep brain stimulation (DBS) electrode implantations. The authors conducted a study to evaluate this application accuracy in routine frame-based DBS procedures, with an independent system of measurement.
METHODS
The Euclidian distance was measured between the point theoretically targeted by the robot and the point actually reached, based on their respective stereotactic coordinates. The coordinates of the theoretical target were given by the robot's dedicated targeting software. The coordinates of the point actually reached were recalculated using the Stereoplan localizer system. This experiment was performed in vitro, with the frame fixed in the robot space without a patient, for 21 points spatially distributed. The in vivo accuracy was then measured in 30 basal ganglia targets in 17 consecutive patients undergoing DBS for movement disorders.
RESULTS
The mean in vitro application accuracy was 0.44 ± 0.23 mm. The maximal localization error was 1.0 mm. The mean (± SD) in vivo application accuracy was 0.86 ± 0.32 mm (Δx = 0.37 ± 0.34 mm, Δy = 0.32 ± 0.24 mm, Δz = 0.58 ± 0.31 mm). The maximal error was 1.55 mm.
CONCLUSIONS
The in vivo application accuracy of the Neuromate neurosurgical robot, measured with a system independent from the robot, in frame-based DBS procedures was better than 1 mm. This accuracy is at least similar to the accuracy of stereotactic frame arms and is compatible with the accuracy required in DBS procedures.
Collapse
Affiliation(s)
| | - Philippe Paquis
- 1Department of Neurosurgery, Centre Hospitalier Universitaire de Nice; and
| | - Denys Fontaine
- 1Department of Neurosurgery, Centre Hospitalier Universitaire de Nice; and
- 2IGCN-EA 7282 (Image-Guided Clinical Neuroscience and Connectomics), UMR 6284 ISIT, Université d'Auvergne, Clermont-Ferrand, France
| |
Collapse
|
26
|
Talibi SS, Talibi SS, Aweid B, Aweid O. Prospective therapies for high-grade glial tumours: A literature review. Ann Med Surg (Lond) 2014; 3:55-9. [PMID: 25568787 PMCID: PMC4284454 DOI: 10.1016/j.amsu.2014.04.003] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2013] [Revised: 04/16/2014] [Accepted: 04/18/2014] [Indexed: 11/24/2022] Open
Abstract
After three decades of intensive research, cytoreductive surgery remains the gold standard of treatment of malignant gliomas. Survivorship at both 1-year and 5-years has not drastically changed in the UK. Concomitant chemo- and radiotherapy has enhanced the efficiency of surgery, enabling more aggressive tumour resection whilst also preserving the surrounding healthy brain parenchyma. More accurate imaging techniques have also played a role in tumour identification, key to this has been pre- and intra-operative contrast enhancement and compounds that have a high affinity in binding to glioma cells. Intra-operative imaging has heralded the ability to give the operating surgeon continuous feedback to assess the completeness of resection. Research is shifting into investigating the complex cellular and molecular glial tumour-genesis, and has led to the development of efficacious chemotherapy agents and trial novel therapies. Oncolytic virotherapy has shown promise in clinical trials and gene therapy in-vitro studies. Surgery however remains the primary therapeutic option for the management of malignant gliomas removing the mass of proliferating malignant tumour cells and decompression of the space-occupying lesion.
Collapse
Affiliation(s)
- Sayed Samed Talibi
- University Hospital of North Staffordshire, Stoke-on-Trent, United Kingdom
| | | | | | - Osama Aweid
- West Suffolk Hospital, Bury St Edmunds, Trauma and Orthopaedics ST3, United Kingdom
| |
Collapse
|
27
|
Affiliation(s)
- Jay Shah
- College of Human Medicine, Michigan State University, 1200 East Michigan Avenue, Suite 655, Lansing, MI 48912
| | - Arpita Vyas
- Assistant Professor, Department of Pediatrics, Adjunct Professor, Institute of International Health, College of Human Medicine, Michigan State University, 1200 East Michigan Avenue, Suite 655, Lansing, MI 48912
| | - Dinesh Vyas
- Assistant Professor, Department of Surgery, Advanced Robotic and GI Surgeon, Adjunct Professor, Institute of International Health, Director, MS Surgery Clerkship, College of Human Medicine, Michigan State University, 1200 East Michigan Avenue, Suite 655, Lansing, MI 48912,
| |
Collapse
|
28
|
Azar AT, Eljamel MS. Medical Robotics. ROBOTICS 2013. [DOI: 10.4018/978-1-4666-4607-0.ch054] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
Abstract
Medical robotics is an interdisciplinary field that focuses on developing electromechanical devices for clinical applications. The goal of this field is to enable new medical techniques by providing new capabilities to the physician or by providing assistance during surgical procedures. Medical robotics is a relatively young field, as the first recorded medical application occurred in 1985 for a brain biopsy. It has tremendous potential for improving the precision and capabilities of physicians when performing surgical procedures, and it is believed that the field will continue to grow as improved systems become available. This chapter offers a comprehensive overview about medical robotics field and its applications. It begins with an introduction to robotics, followed by a historical review of their use in medicine. Clinical applications in several different medical specialties are discusssed. The chapter concludes with a discussion of technology challenges and areas for future research.
Collapse
|
29
|
Abstract
Medical robotics is an interdisciplinary field that focuses on developing electromechanical devices for clinical applications. The goal of this field is to enable new medical techniques by providing new capabilities to the physician or by providing assistance during surgical procedures. Medical robotics is a relatively young field, as the first recorded medical application occurred in 1985 for a brain biopsy. It has tremendous potential for improving the precision and capabilities of physicians when performing surgical procedures, and it is believed that the field will continue to grow as improved systems become available. This chapter offers a comprehensive overview about medical robotics field and its applications. It begins with an introduction to robotics, followed by a historical review of their use in medicine. Clinical applications in several different medical specialties are discusssed. The chapter concludes with a discussion of technology challenges and areas for future research.
Collapse
|
30
|
Telerobotic contact transscleral cyclophotocoagulation of the ciliary body with the diode laser. J Robot Surg 2013; 8:49-55. [PMID: 27637239 DOI: 10.1007/s11701-013-0424-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2013] [Accepted: 07/15/2013] [Indexed: 10/26/2022]
Abstract
To assess the feasibility of using the Robotic Slave Micromanipulator Unit (RSMU) to remotely photocoagulate the ciliary body for the treatment of glaucoma with the diode laser. In fresh unoperated enucleated human eyes, the ciliary body was destroyed either with a standard contact transscleral cyclophotocoagulation 'by hand' diode laser technique, or remotely using the RSMU. The treated sections were fixed in formalin, paraffin-embedded, and stained with hematoxylin and eosin. Histological evaluation was performed by a masked observer using a standardized grading system based on the amount of damage to the ciliary body to evaluate effectiveness of treatment. Both methods of contact transscleral cyclophotocoagulation showed therapeutic tissue disruption of the ciliary processes and both the non-pigmented and pigmented ciliary epithelium. Histology examination of remote robotic contact transscleral cyclophotocoagulation and "by hand" technique produced similar degrees of ciliary body tissue disruption. Remote diode laser contact transscleral cyclophotocoagulation of the ciliary body in fresh enucleated human eyes is possible with the RSMU. Therapeutic tissue disruption of the ciliary body was achieved. Additional study is necessary to determine the safety and efficacy of robotically-delivered cyclophotocoagulation in live eyes.
Collapse
|
31
|
Vaccarella A, Enquobahrie A, Ferrigno G, Momi ED. Modular multiple sensors information management for computer-integrated surgery. Int J Med Robot 2012; 8:253-60. [PMID: 22407822 DOI: 10.1002/rcs.1412] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/07/2011] [Indexed: 12/17/2022]
Abstract
BACKGROUND In the past 20 years, technological advancements have modified the concept of modern operating rooms (ORs) with the introduction of computer-integrated surgery (CIS) systems, which promise to enhance the outcomes, safety and standardization of surgical procedures. With CIS, different types of sensor (mainly position-sensing devices, force sensors and intra-operative imaging devices) are widely used. Recently, the need for a combined use of different sensors raised issues related to synchronization and spatial consistency of data from different sources of information. METHODS In this study, we propose a centralized, multi-sensor management software architecture for a distributed CIS system, which addresses sensor information consistency in both space and time. The software was developed as a data server module in a client-server architecture, using two open-source software libraries: Image-Guided Surgery Toolkit (IGSTK) and OpenCV. The ROBOCAST project (FP7 ICT 215190), which aims at integrating robotic and navigation devices and technologies in order to improve the outcome of the surgical intervention, was used as the benchmark. An experimental protocol was designed in order to prove the feasibility of a centralized module for data acquisition and to test the application latency when dealing with optical and electromagnetic tracking systems and ultrasound (US) imaging devices. RESULTS Our results show that a centralized approach is suitable for minimizing synchronization errors; latency in the client-server communication was estimated to be 2 ms (median value) for tracking systems and 40 ms (median value) for US images. CONCLUSION The proposed centralized approach proved to be adequate for neurosurgery requirements. Latency introduced by the proposed architecture does not affect tracking system performance in terms of frame rate and limits US images frame rate at 25 fps, which is acceptable for providing visual feedback to the surgeon in the OR.
Collapse
Affiliation(s)
- Alberto Vaccarella
- NearLab, Dipartimento di Bioingegneria, Politecnico di Milano, Milano, Italy.
| | | | | | | |
Collapse
|
32
|
Butler EJ, Hammond-Oakley R, Chawarski S, Gosline AH, Codd P, Anor T, Madsen JR, Dupont PE, Lock J. Robotic Neuro-Endoscope with Concentric Tube Augmentation. PROCEEDINGS OF THE ... IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS. IEEE/RSJ INTERNATIONAL CONFERENCE ON INTELLIGENT ROBOTS AND SYSTEMS 2012:10.1109/IROS.2012.6386022. [PMID: 24232193 PMCID: PMC3825412 DOI: 10.1109/iros.2012.6386022] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/12/2023]
Abstract
Surgical robots are gaining favor in part due to their capacity to reach remote locations within the body. Continuum robots are especially well suited for accessing deep spaces such as cerebral ventricles within the brain. Due to the entry point constraints and complicated structure, current techniques do not allow surgeons to access the full volume of the ventricles. The ability to access the ventricles with a dexterous robot would have significant clinical implications. This paper presents a concentric tube manipulator mated to a robotically controlled flexible endoscope. The device adds three degrees of freedom to the standard neuroendoscope and roboticizes the entire package allowing the operator to conveniently manipulate the device. To demonstrate the improved functionality, we use an in-silica virtual model as well as an ex-vivo anatomic model of a patient with a treatable form of hydrocephalus. In these experiments we demonstrate that the augmented and roboticized endoscope can efficiently reach critical regions that a manual scope cannot.
Collapse
Affiliation(s)
| | | | | | - Andrew H. Gosline
- Cardiovascular Surgery, Children’s Hospital Boston, Harvard Medical School, Boston MA 02115 USA
| | - Patrick Codd
- Neurosurgery, Children’s Hospital Boston, Harvard Medical School, Boston MA 02115 USA
| | - Tomer Anor
- Neurosurgery, Children’s Hospital Boston, Harvard Medical School, Boston MA 02115 USA
| | - Joseph R. Madsen
- Neurosurgery, Children’s Hospital Boston, Harvard Medical School, Boston MA 02115 USA
| | - Pierre E. Dupont
- Cardiovascular Surgery, Children’s Hospital Boston, Harvard Medical School, Boston MA 02115 USA
| | - Jesse Lock
- Sterling Point Research LLC, Winchester MA 01890 USA
| |
Collapse
|
33
|
Advances in Haptics, Tactile Sensing, and Manipulation for Robot-Assisted Minimally Invasive Surgery, Noninvasive Surgery, and Diagnosis. JOURNAL OF ROBOTICS 2012. [DOI: 10.1155/2012/412816] [Citation(s) in RCA: 28] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The developments of medical practices and medical technologies have always progressed concurrently. The relatively recent developments in endoscopic technologies have allowed the realization of the “minimally invasive” form of surgeries. The advancements in robotics facilitate precise surgeries that are often integrated with medical image guidance capability. This in turn has driven the further development of technology to compensate for the unique complexities engendered by this new format and to improve the performance and broaden the scope of the procedures that can be performed. Medical robotics has been a central component of this development due to the highly suitable characteristics that a robotic system can purport, including highly optimizable mechanical conformation and the ability to program assistive functions in medical robots for surgeons to perform safe and accurate minimally invasive surgeries. In addition, combining the robot-assisted interventions with touch-sensing and medical imaging technologies can greatly improve the available information and thus help to ensure that minimally invasive surgeries continue to gain popularity and stay at the focus of modern medical technology development. This paper presents a state-of-the-art review of robotic systems for minimally invasive and noninvasive surgeries, precise surgeries, diagnoses, and their corresponding technologies.
Collapse
|
34
|
Colen RR, Kekhia H, Jolesz FA. Multimodality intraoperative MRI for brain tumor surgery. Expert Rev Neurother 2011; 10:1545-58. [PMID: 20945538 DOI: 10.1586/ern.10.145] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Intraoperative MRI has already fundamentally changed the way current brain tumor surgery is performed. The ability to integrate high-field MRI into the operating room has allowed intraoperative MRI to emerge as an important adjunct to CNS tumor treatment. Furthermore, the ability of MRI to successfully couple with molecular imaging (PET and/or optical imaging), neuroendoscopy and therapeutic devices, such as focused ultrasound, will allow it to emerge as an important image-guidance modality for improving brain tumor therapy and outcomes.
Collapse
Affiliation(s)
- Rivka R Colen
- Department of Radiology, Brigham and Women's Hospital, Harvard Medical School, 75 Francis Street, Boston, MA 02115, USA
| | | | | |
Collapse
|
35
|
Brodie J, Eljamel S. Evaluation of a neurosurgical robotic system to make accurate burr holes. Int J Med Robot 2011; 7:101-6. [DOI: 10.1002/rcs.376] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 12/12/2010] [Indexed: 11/09/2022]
|
36
|
Haegelen C, Touzet G, Reyns N, Maurage CA, Ayachi M, Blond S. Stereotactic robot-guided biopsies of brain stem lesions: Experience with 15 cases. Neurochirurgie 2010; 56:363-7. [DOI: 10.1016/j.neuchi.2010.05.006] [Citation(s) in RCA: 30] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2007] [Accepted: 04/09/2010] [Indexed: 10/19/2022]
|
37
|
Frasson L, Ko SY, Turner A, Parittotokkaporn T, Vincent JF, Rodriguez y Baena F. STING: a soft-tissue intervention and neurosurgical guide to access deep brain lesions through curved trajectories. Proc Inst Mech Eng H 2010; 224:775-88. [PMID: 20608494 DOI: 10.1243/09544119jeim663] [Citation(s) in RCA: 52] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Current trends in surgical intervention favour a minimally invasive approach, in which complex procedures are performed through very small incisions. Specifically, in neurosurgery there is a need for minimally invasive keyhole access, which conflicts with the lack of manoeuvrability of conventional rigid instruments. In an attempt to address this shortcoming, the current state of progress is reported on a soft-tissue intervention and neurosurgical guide (STING) to access deep brain lesions through curved trajectories. The underlying mechanism of motion, based on the reciprocal movement of interlocked probe segments, is biologically inspired and was designed around the unique features of the ovipositor of certain parasitic wasps. Work to date has focused on probe development, low- and high-level control, and trajectory planning. These aspects are described, together with results on each aspect of the work, including biomimetic microtexturing of the probe surface. Progress is very encouraging and demonstrates that forward motion into soft tissue through a reciprocating mechanism is indeed viable and can be achieved through a suitable combination of microtexturing and microfabrication techniques.
Collapse
Affiliation(s)
- L Frasson
- Department of Mechanical Engineering, Imperial College London, London, UK
| | | | | | | | | | | |
Collapse
|
38
|
Alric M, Chapelle F, Lemaire JJ, Gogu G. Potential applications of medical and non-medical robots for neurosurgical applications. MINIM INVASIV THER 2010; 18:193-216. [PMID: 19548175 DOI: 10.1080/13645700903053584] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
Abstract
The objective of the paper is to review the state-of-the-art in medical robotic systems used for different surgical applications, and to position and evaluate their concepts according to the design requirements of an innovative, robotized neurosurgical system, capable of performing tumor ablation or electrode positioning. A few other non-medical systems, which have interesting concepts, will also be discussed. The overall aim is to determine the robotic concept (structure, actuation, etc.) most applicable to specific tasks in neurosurgery. The first section of the article describes the requirements of the task and each important aspect is expressed by an evaluation criterion. Then, 59 systems are described, according to the fields of medical applications and the robotic concepts. An evaluation of the different systems is conducted, based on the five most significant criteria. However, the main characteristic assessed is the deployment capability of the system i.e. extension and retraction. The final section presents an overview of concepts transferable to neurosurgical applications. Continuum concepts, such as "elephant trunks", seem to be the most adapted solutions, utilizing pneumatic and/or spring and/or cable actuations. Pneumatics offer deployment forces and cables can control and guide the deployment. The design of a new neurosurgical device should take into account these observations as a base.
Collapse
Affiliation(s)
- Matthieu Alric
- Laboratoire de Mécaniqueet Ingénieries (LaMI), Université Blaise Pascal & Institut Français de Mécanique Avancée (IFMA), Campus de Clermont-Ferrand, Les Cézeaux, Aubière, France.
| | | | | | | |
Collapse
|
39
|
Omar EAZ, Bamber MA. Orthognathic model surgery by using of a passive Robot Arm. Saudi Dent J 2010; 22:47-55. [PMID: 24227912 DOI: 10.1016/j.sdentj.2010.02.006] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2009] [Revised: 06/16/2009] [Accepted: 07/08/2009] [Indexed: 11/28/2022] Open
Abstract
PURPOSE The possibility of using a passive Robot Arm (3D method) in model surgery and comparing with manual technique model surgery. PATIENTS AND METHODS Seventeen patients undergoing orthognathic surgery gave consent for this study. Model surgery was performed by using a manual technique and using the Robot Arm. The model surgery that was performed by using the manual technique named group A and the one performed by the Robot Arm named group B. Patients' maxillary casts were measured before and after model surgery, and results were compared with those for the original treatment plan in the horizontal (X-axis), vertical (Y-axis), and transverse (Z-axis) planes. RESULTS Statistical analysis using Mann-Whitney U test for X- and Y-axis and independent sample t test for Z-axis have shown significant differences between both groups in X-axis (P = .026) and Y-axis (P = .021) but not in Z-axis (P = .762). CONCLUSIONS Model surgery performed with a Robot Arm is more accurate in all dimensions X, Y, and Z than the manual model surgery.
Collapse
Affiliation(s)
- Esam Ahmad Z Omar
- Oral and Maxillofacial Surgery, College of Dentistry, Taibah University, Al-Madinah, Saudi Arabia
| | | |
Collapse
|
40
|
Abstract
Neurosurgical diagnosis and intervention has evolved through improved neuroimaging, allowing better visualization of anatomy and pathology. This article discusses the various systems that have been designed over the last decade to meet the requirements of neurosurgical patients and opines on the potential future developments in the technology and application of intraoperative MRI. Because the greatest amount of experience with intraoperative MRI comes from its use in brain tumor resection, this article focuses on the origins of intraoperative MRI in relation to this field.
Collapse
|
41
|
Joskowicz L, Shamir R, Freiman M, Shoham M, Zehavi E, Umansky F, Shoshan Y. Image-guided system with miniature robot for precise positioning and targeting in keyhole neurosurgery. ACTA ACUST UNITED AC 2010; 11:181-93. [PMID: 17038306 DOI: 10.3109/10929080600909351] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/13/2022]
Abstract
This paper describes a novel image-guided system for precise automatic targeting in minimally invasive keyhole neurosurgery. The system consists of the MARS miniature robot fitted with a mechanical guide for needle, probe or catheter insertion. Intraoperatively, the robot is directly affixed to a head clamp or to the patient's skull. It automatically positions itself with respect to predefined targets in a preoperative CT/MRI image following an anatomical registration with an intraoperative 3D surface scan of the patient's facial features and registration jig. We present the system architecture, surgical protocol, custom hardware (targeting and registration jig), and software modules (preoperative planning, intraoperative execution, 3D surface scan processing, and three-way registration). We also describe a prototype implementation of the system and in vitro registration experiments. Our results indicate a system-wide target registration error of 1.7 mm (standard deviation = 0.7 mm), which is close to the required 1.0-1.5 mm clinical accuracy in many keyhole neurosurgical procedures.
Collapse
Affiliation(s)
- L Joskowicz
- School of Engineering and Computer Science, The Hebrew University of Jerusalem, Jerusalem, Israel.
| | | | | | | | | | | | | |
Collapse
|
42
|
|
43
|
Abstract
SUMMARYIn the past years a large number of new surgical devices have been developed to improve the operation outcomes and reduce the patient's trauma. Nevertheless, the dexterity and accuracy required in positioning the surgical tools are often unreachable if the surgeons are not assisted by a suitable system. Since a medical robot works in an operating room, close to the patient and the medical staff, it has to satisfy much stricter requirements with respect to an industrial one. From a kinematic point of view, the robot must reach any target position in the patient's body, being as less invasive as possible for the surgeon's workspace. In order to meet such requirements, the right robot structure has to be chosen by means of the definition of suitable kinematic performance indices.In this paper some task-based indices based on the robot workspace and stiffness are presented and discussed. The indices will be used in a multiobjective optimization problem to evaluate best robot kinematic structure for a given neurosurgical task.
Collapse
|
44
|
Image-guided robotic neurosurgery—an in vitro and in vivo point accuracy evaluation experimental study. ACTA ACUST UNITED AC 2009; 71:640-7, discussion 647-8. [DOI: 10.1016/j.surneu.2008.06.008] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2007] [Accepted: 06/12/2008] [Indexed: 11/21/2022]
|
45
|
Abstract
Neurosurgical diagnosis and intervention has evolved through improved neuroimaging, allowing better visualization of anatomy and pathology. This article discusses the various systems that have been designed over the last decade to meet the requirements of neurosurgical patients and opines on the potential future developments in the technology and application of intraoperative MRI. Because the greatest amount of experience with intraoperative MRI comes from its use in brain tumor resection, this article focuses on the origins of intraoperative MRI in relation to this field.
Collapse
Affiliation(s)
- John M.K. Mislow
- Department of Neurosurgery, Harvard Medical School, Brigham and Women's Hospital, 75 Francis Street, Boston, MA 02115, USA
| | - Alexandra J. Golby
- Department of Neurosurgery, Harvard Medical School, Brigham and Women's Hospital, 75 Francis Street, Boston, MA 02115, USA
| | - Peter M. Black
- Department of Neurosurgery, Harvard Medical School, Brigham and Women's Hospital, 75 Francis Street, Boston, MA 02115, USA
| |
Collapse
|
46
|
Moche M, Trampel R, Kahn T, Busse H. Navigation concepts for MR image-guided interventions. J Magn Reson Imaging 2008; 27:276-91. [DOI: 10.1002/jmri.21262] [Citation(s) in RCA: 49] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022] Open
|
47
|
Sukovich W, Brink-Danan S, Hardenbrook M. Miniature robotic guidance for pedicle screw placement in posterior spinal fusion: early clinical experience with the SpineAssist. Int J Med Robot 2007; 2:114-22. [PMID: 17520622 DOI: 10.1002/rcs.86] [Citation(s) in RCA: 77] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
BACKGROUND Spinal fusion is a commonly performed procedure for a variety of conditions. Pedicle screw fixation has become the standard of care for stabilization of the thoracic and lumbar spine. Precise screw placement is essential to avoid injury to adjacent neural structures. Patients with severe deformity or prior surgery present a challenge to the accurate placement of pedicle screws. Additionally, minimally invasive and percutaneous surgical techniques also present a greater challenge to accurate screw placement and require heavier reliance on intraoperative fluoroscopic imaging, which presents an occupational hazard for the surgeon and the operating-room (OR) staff. The purpose of this paper is to introduce the SpineAssist, a miniature robotic guidance system, developed to assist spine surgeons in the accurate placement of pedicle screws. METHODS The operative technique is described, as is the experience and results with 14 patients during a 6 month period during which this system was used. RESULTS The SpineAssist performed successfully in 93% of the cases in which it was used. 96% of the screws placed were determined to be within 1 mm of their planned trajectory. CONCLUSIONS Difficulties encountered with use of the SpineAssist, while minimal, will be described and suggestions made for future improvements.
Collapse
Affiliation(s)
- W Sukovich
- Spinal Surgery Associates, Charlottesville, VA, USA.
| | | | | |
Collapse
|
48
|
Woerdeman PA, Willems PWA, Noordmans HJ, van der Sprenkel JWB. The analysis of intraoperative neurosurgical instrument movement using a navigation log-file. Int J Med Robot 2007; 2:139-45. [PMID: 17520624 DOI: 10.1002/rcs.91] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
BACKGROUND The purpose of this study was to define the technical requirements of future (tele)robotic neurosurgical systems. We aimed to analyse the movements of surgical instruments during neurosurgical procedures. METHODS A commercially available neuronavigation system (StealthStation TREON(plus), Medtronic, USA) was used to determine the position and orientation of the surgical instrument. A custom-made log-mode was implemented in the software to file instrument coordinates intraoperatively. Data was collected during the debulking of malignant primary brain tumours, temporal epilepsy surgery and skull base tumour surgery. RESULTS Maximum tip displacement velocity varied, per procedure, in the range 6.6-12.7 cm/s and maximum rotational speed 21-40 degrees/s. Maximum instrument orientation differences within the volume of movement varied. The largest differences were detected during temporal epilepsy surgery (73 degrees and 52 degrees in the coronal and axial planes, respectively), while the smallest differences were detected in the debulking of an intraventricular tumour. CONCLUSIONS In this study, we have demonstrated the feasibility of motion analysis in image-guided neurosurgery. To mimic ordinary open neurosurgery, future neurosurgical (tele)robotic systems should at least support translational speeds up to 12.7 cm/s, rotational speeds up to 40 degrees/s and differences in instrument orientation of up to 73 degrees.
Collapse
Affiliation(s)
- P A Woerdeman
- Rudolf Magnus Institute of Neuroscience, Department of Neurosurgery, University Medical Center Utrecht, The Netherlands.
| | | | | | | |
Collapse
|
49
|
Dimaio SP, Archip N, Hata N, Talos IF, Warfield SK, Majumdar A, Mcdannold N, Hynynen K, Morrison PR, Wells WM, Kacher DF, Ellis RE, Golby AJ, Black PM, Jolesz FA, Kikinis R. Image-guided neurosurgery at Brigham and Women's Hospital. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE : THE QUARTERLY MAGAZINE OF THE ENGINEERING IN MEDICINE & BIOLOGY SOCIETY 2006; 25:67-73. [PMID: 17020201 DOI: 10.1109/memb.2006.1705749] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Simon P Dimaio
- Harvard Medical School, Brigham and Women's Hospital, Boston, Massachusetts, USA.
| | | | | | | | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|