1
|
Li Z, Ma J, Hong J, Yu H, Chen Y, Zhu L, Bao C. Sensitively detecting antigen of SARS-CoV-2 by a homogeneous immunoassay based on ortho-touch reaction and graphene oxide (GO) quenched acridine esterification chemiluminescence. Diagn Microbiol Infect Dis 2025; 112:116849. [PMID: 40273652 DOI: 10.1016/j.diagmicrobio.2025.116849] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2024] [Revised: 04/10/2025] [Accepted: 04/12/2025] [Indexed: 04/26/2025]
Abstract
In this study, a homogeneous immunoassay based on ortho-touch reaction and graphene oxide (GO) quenched acridine esterification chemiluminescence is developed for sensitive detection of SARS-CoV-2 antigen. The sensitivity and specificity of this method was further evaluated with viral protein, virus strains and clinical samples. Benefiting from strong chemiluminescence signal and good quenching performance of GO, this method allows enhanced signal-to-background ratio, and the limit of detection is down to 0.02 ng/ml of viral protein or equivalently 200 copies/ml of virus strains. In clinical evaluations, our approach demonstrated a high level of agreement with digital RT-PCR, achieving a positive coincidence rate of 90.87 %, a negative coincidence rate of 99.77 %, and an overall concordance of 96.53 %, while showing no cross-reactivity with other prevalent viruses. This method offers a promising, sensitive, rapid, and cost-effective platform for early SARS-CoV-2 diagnosis. Moreover, it can potentially be adapted for detecting other pathogens.
Collapse
Affiliation(s)
- Zhifeng Li
- Department of Acute Infectious Diseases Control and Prevention, Jiangsu Provincial Center for Disease Control and Prevention, Nanjing, Jiangsu Province 210009, China
| | - Juntao Ma
- Department of Laboratory Medicine, Nanjing Drum Tower Hospital Clinical College of Nanjing University of Chinese Medicine, Nanjing, Jiangsu Province 210009, China
| | - Jie Hong
- Department of Acute Infectious Diseases Control and Prevention, Jiangsu Provincial Center for Disease Control and Prevention, Nanjing, Jiangsu Province 210009, China
| | - Huiyan Yu
- Department of Acute Infectious Diseases Control and Prevention, Jiangsu Provincial Center for Disease Control and Prevention, Nanjing, Jiangsu Province 210009, China
| | - Yuxin Chen
- Department of Laboratory Medicine, Nanjing Drum Tower Hospital Clinical College of Nanjing University of Chinese Medicine, Nanjing, Jiangsu Province 210009, China
| | - Liguo Zhu
- Department of Acute Infectious Diseases Control and Prevention, Jiangsu Provincial Center for Disease Control and Prevention, Nanjing, Jiangsu Province 210009, China
| | - Changjun Bao
- Department of Acute Infectious Diseases Control and Prevention, Jiangsu Provincial Center for Disease Control and Prevention, Nanjing, Jiangsu Province 210009, China.
| |
Collapse
|
2
|
Hlekelele L, Setshedi K, Mandiwana V, Kalombo L, Lemmer Y, Chauke V, Maity A. Carboxy-PEG-thiol functionalized gold nanoparticle conjugates for the detection of SARS-CoV-2: Detection tools and analytical method development. J Virol Methods 2024; 330:115028. [PMID: 39236987 DOI: 10.1016/j.jviromet.2024.115028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2024] [Accepted: 08/30/2024] [Indexed: 09/07/2024]
Abstract
Addressing the need for accessible SARS-CoV-2 testing, carboxy-PEG 12-thiol functionalized gold nanoparticles conjugates were developed for rapid point-of-care (POC) detection against SARS-CoV-2 spike protein, pseudo-SARS-CoV-2, and authentic Beta SARS-CoV-2 virus particles. These conjugates leverage gold nanoparticles (AuNPs) as signal transducers, cross-linked to either angiotensin-converting enzyme 2 (ACE2) or SARS-CoV-2 spike protein receptor-binding domain (RBD) antibodies as bioreceptors and showed a distinct color shift from pink to blue. To assess their POC feasibility, the conjugates were integrated into facemasks and breathalyzers, wherein aerosolized SARS-CoV-2 antigens were successfully detected, producing a color change within 10 and 30 minutes for the breathalyzer and facemask prototypes, respectively. Furthermore, we explored quantitative analysis using varying concentrations of SARS-CoV-2 spike protein. Both conjugates demonstrated a linear relationship between blue color intensity and virus concentration, with linear ranges of 0.08-0.6 ng/mL and 0.04-0.5 ng/mL, respectively. Low limits of detection and quantification were also achieved. They exhibited specificity, responding solely to SARS-CoV-2 even in complex matrices containing diverse proteins, including the SARS-CoV-1 spike protein. Precision tests yielded coefficient of variations below 2 %, showcasing their remarkable reproducibility. This work presents a promising approach for rapid, sensitive, and specific POC detection of SARS-CoV-2 paving the way for improved pandemic response and management.
Collapse
Affiliation(s)
- Lerato Hlekelele
- Centre for Nanostructures and Advanced Materials, DSI-CSIR Nanotechnology Innovation Centre, Council for Scientific and Industrial Research, Pretoria 0001, South Africa.
| | - Katlego Setshedi
- Centre for Nanostructures and Advanced Materials, DSI-CSIR Nanotechnology Innovation Centre, Council for Scientific and Industrial Research, Pretoria 0001, South Africa
| | - Vusani Mandiwana
- Centre for Nanostructures and Advanced Materials, DSI-CSIR Nanotechnology Innovation Centre, Council for Scientific and Industrial Research, Pretoria 0001, South Africa
| | - Lonji Kalombo
- Centre for Nanostructures and Advanced Materials, DSI-CSIR Nanotechnology Innovation Centre, Council for Scientific and Industrial Research, Pretoria 0001, South Africa
| | - Yolandy Lemmer
- Next Generation Health, Council for Scientific and Industrial Research, Pretoria 0001, South Africa
| | - Vongani Chauke
- Centre for Nanostructures and Advanced Materials, DSI-CSIR Nanotechnology Innovation Centre, Council for Scientific and Industrial Research, Pretoria 0001, South Africa
| | - Arjun Maity
- Centre for Nanostructures and Advanced Materials, DSI-CSIR Nanotechnology Innovation Centre, Council for Scientific and Industrial Research, Pretoria 0001, South Africa; Department of Chemical Engineering, Faculty of Engineering, Built Environment and Information Technology, University of Pretoria, Pretoria, South Africa.
| |
Collapse
|
3
|
Adeniyi K, Oyinlola K, Achadu OJ, Menard H, Grillo F, Yang Z, Adegoke O. Molecularly Imprinted Viral Protein Integrated Zn-Cu-In-Se-P Quantum Dots Superlattice for Quantitative Ratiometric Electrochemical Detection of SARS-CoV-2 Spike Protein in Saliva. ACS APPLIED NANO MATERIALS 2024; 7:17630-17647. [PMID: 39144398 PMCID: PMC11320384 DOI: 10.1021/acsanm.4c02882] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/17/2024] [Revised: 07/17/2024] [Accepted: 07/18/2024] [Indexed: 08/16/2024]
Abstract
Solution-processable colloidal quantum dots (QDs) are promising materials for the development of rapid and low-cost, next-generation quantum-sensing diagnostic systems. In this study, we report on the synthesis of multinary Zn-Cu-In-Se-P (ZCISeP) QDs and the application of the QDs-modified electrode (QDs/SPCE) as a solid superlattice transducer interface for the ratiometric electrochemical detection of the SARS-CoV-2-S1 protein in saliva. The ZCISeP QDs were synthesized through the formation of In(Zn)PSe QDs from InP QDs, followed by the incorporation of Cu cations into the crystal lattice via cation exchange processes. A viral-protein-imprinted polymer film was deposited onto the QDs/SPCE for the specific binding of SARS-CoV-2. Molecular imprinting of the virus protein was achieved using a surface imprinting electropolymerization strategy to create the MIP@QDs/SPCE nanosensor. Characterization through spectroscopic, microscopic, and electrochemical techniques confirmed the structural properties and electronic-band state of the ZCISeP QDs. Cyclic voltammetry studies of the QDs/SPCE superlattice confirmed efficient electron transport properties and revealed an intraband gap energy state with redox peaks attributed to the Cu1+/2+ defects. Binding of SARS-CoV-2-S1 to the MIP@QDs/SPCE cavities induced a gating effect that modulated the Fe(CN)6 3-/4- and Cu1+/2+ redox processes at the nanosensor interface, producing dual off/on ratiometric electrical current signals. Under optimal assay conditions, the nanosensor exhibited a wide linear detection range (0.001-100 pg/mL) and a low detection limit (0.34 pg/mL, 4.6 fM) for quantitative detection of SARS-CoV-2-S1 in saliva. The MIP@QDs/SPCE nanosensor demonstrated excellent selectivity against nonspecific protein targets, and the integration with a smartphone-based potentiostat confirmed the potential for point-of-care applications.
Collapse
Affiliation(s)
- Kayode
Omotayo Adeniyi
- Leverhulme
Research Centre for Forensic Science, School of Science & Engineering, University of Dundee, Dundee DD1 4GH, U.K.
| | - Kayode Oyinlola
- Leverhulme
Research Centre for Forensic Science, School of Science & Engineering, University of Dundee, Dundee DD1 4GH, U.K.
| | - Ojodomo J. Achadu
- School
of Health and Life Sciences, and National Horizon Centre, Teesside University, Middlesbrough TS1 3BA, U.K.
| | - Herve Menard
- Leverhulme
Research Centre for Forensic Science, School of Science & Engineering, University of Dundee, Dundee DD1 4GH, U.K.
| | - Federico Grillo
- School
of Chemistry, University of St Andrews, St Andrews KY16 9ST, U.K.
| | - Zhugen Yang
- School
of Water, Energy and Environment, Cranfield
University, Cranfield MK43 0AL, U.K.
| | - Oluwasesan Adegoke
- Leverhulme
Research Centre for Forensic Science, School of Science & Engineering, University of Dundee, Dundee DD1 4GH, U.K.
| |
Collapse
|
4
|
Nisar S, Dastgeer G, Shazad ZM, Zulfiqar MW, Rasheed A, Iqbal MZ, Hussain K, Rabani I, Kim D, Irfan A, Chaudhry AR. 2D Materials in Advanced Electronic Biosensors for Point-of-Care Devices. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2401386. [PMID: 38894575 PMCID: PMC11336981 DOI: 10.1002/advs.202401386] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/06/2024] [Revised: 05/18/2024] [Indexed: 06/21/2024]
Abstract
Since two-dimensionalal (2D) materials have distinct chemical and physical properties, they are widely used in various sectors of modern technologies. In the domain of diagnostic biodevices, particularly for point-of-care (PoC) biomedical diagnostics, 2D-based field-effect transistor biosensors (bio-FETs) demonstrate substantial potential. Here, in this review article, the operational mechanisms and detection capabilities of biosensing devices utilizing graphene, transition metal dichalcogenides (TMDCs), black phosphorus, and other 2D materials are addressed in detail. The incorporation of these materials into FET-based biosensors offers significant advantages, including low detection limits (LOD), real-time monitoring, label-free diagnosis, and exceptional selectivity. The review also highlights the diverse applications of these biosensors, ranging from conventional to wearable devices, underscoring the versatility of 2D material-based FET devices. Additionally, the review provides a comprehensive assessment of the limitations and challenges faced by these devices, along with insights into future prospects and advancements. Notably, a detailed comparison of FET-based biosensors is tabulated along with various other biosensing platforms and their working mechanisms. Ultimately, this review aims to stimulate further research and innovation in this field while educating the scientific community about the latest advancements in 2D materials-based biosensors.
Collapse
Affiliation(s)
- Sobia Nisar
- Department of Electrical EngineeringSejong UniversitySeoul05006Republic of Korea
- Department of Convergence Engineering for Intelligent DroneSejong UniversitySeoul05006Republic of Korea
| | - Ghulam Dastgeer
- Department of Physics & AstronomySejong UniversitySeoul05006Republic of Korea
| | - Zafar Muhammad Shazad
- SKKU Advanced Institute of Nanotechnology (SAINT)Sungkyunkwan UniversitySuwon16419Republic of Korea
- Department of Chemical Polymer and Composite EngineeringUniversity of Engineering & TechnologyFaisalabad CampusLahore38000Pakistan
| | - Muhammad Wajid Zulfiqar
- Department of Electrical EngineeringSejong UniversitySeoul05006Republic of Korea
- Department of Semiconductor EngineeringSejong UniversitySeoul05006Republic of Korea
| | - Amir Rasheed
- School of Materials Science and EngineeringAnhui UniversityHefeiAnhui230601China
| | - Muhammad Zahir Iqbal
- Renewable Energy Research LaboratoryFaculty of Engineering SciencesGhulam Ishaq Khan Institute of Engineering Sciences and TechnologyTopiKhyber Pakhtunkhwa23640Pakistan
| | - Kashif Hussain
- THz Technical Research Center; Shenzhen Key Laboratory of Micro‐Nano Photonic Information Technology; Key Laboratory of Optoelectronic Devices and Systems, College of Physics and Optoelectronic EngineeringShenzhen UniversityShenzhenGuangdong Province518060China
- School of Materials Science and EngineeringCAPTPeking UniversityBeijing100871China
| | - Iqra Rabani
- Department of Nanotechnology and Advanced Materials EngineeringSejong UniversitySeoul05006Republic of Korea
| | - Deok‐kee Kim
- Department of Electrical EngineeringSejong UniversitySeoul05006Republic of Korea
- Department of Convergence Engineering for Intelligent DroneSejong UniversitySeoul05006Republic of Korea
- Department of Semiconductor EngineeringSejong UniversitySeoul05006Republic of Korea
| | - Ahmad Irfan
- Department of ChemistryCollege of ScienceKing Khalid UniversityP. O. Box 9004Abha61413Saudi Arabia
| | - Aijaz Rasool Chaudhry
- Department of PhysicsCollege of ScienceUniversity of BishaP.O. Box 551Bisha61922Saudi Arabia
| |
Collapse
|
5
|
Santos JF, del Rocío Silva-Calpa L, de Souza FG, Pal K. Central Countries' and Brazil's Contributions to Nanotechnology. CURRENT NANOMATERIALS 2024; 9:109-147. [DOI: 10.2174/2405461508666230525124138] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/07/2022] [Revised: 02/09/2023] [Accepted: 03/14/2023] [Indexed: 01/05/2025]
Abstract
Abstract:
Nanotechnology is a cornerstone of the scientific advances witnessed over the past few
years. Nanotechnology applications are extensively broad, and an overview of the main trends
worldwide can give an insight into the most researched areas and gaps to be covered. This document
presents an overview of the trend topics of the three leading countries studying in this area, as
well as Brazil for comparison. The data mining was made from the Scopus database and analyzed
using the VOSviewer and Voyant Tools software. More than 44.000 indexed articles published
from 2010 to 2020 revealed that the countries responsible for the highest number of published articles
are The United States, China, and India, while Brazil is in the fifteenth position. Thematic
global networks revealed that the standing-out research topics are health science, energy,
wastewater treatment, and electronics. In a temporal observation, the primary topics of research are:
India (2020), which was devoted to facing SARS-COV 2; Brazil (2019), which is developing promising
strategies to combat cancer; China (2018), whit research on nanomedicine and triboelectric
nanogenerators; the United States (2017) and the Global tendencies (2018) are also related to the
development of triboelectric nanogenerators. The collected data are available on GitHub. This study
demonstrates the innovative use of data-mining technologies to gain a comprehensive understanding
of nanotechnology's contributions and trends and highlights the diverse priorities of nations in
this cutting-edge field.
Collapse
Affiliation(s)
- Jonas Farias Santos
- Programa de Engenharia da Nanotecnologia, COPPE, Centro de Tecnologia-Cidade Universitária, Universidade
Federal do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Leydi del Rocío Silva-Calpa
- Programa de Engenharia da Nanotecnologia, COPPE, Centro de Tecnologia-Cidade Universitária, Universidade
Federal do Rio de Janeiro, Rio de Janeiro, Brazil
| | - Fernando Gomes de Souza
- Programa de Engenharia da Nanotecnologia, COPPE, Centro de Tecnologia-Cidade Universitária, Universidade
Federal do Rio de Janeiro, Rio de Janeiro, Brazil
- Instituto de Macromoléculas Professora Eloisa Mano, Centro de
Tecnologia-Cidade Universitária, Universidade Federal de Rio de Janeiro, Rio de Janeiro, Brazil
| | - Kaushik Pal
- University Center
for Research and Development (UCRD), Department of Physics, Chandigarh University, Ludhiana - Chandigarh State
Hwy, Mohali, Gharuan, 140413 Punjab, India
| |
Collapse
|
6
|
Shen Y, Yang CT, Li W, Zhou X. Single-virus-sensitive barcode qPCR mediated by the aggregation of gold nanoparticle probes. Analyst 2024; 149:2556-2560. [PMID: 38587837 DOI: 10.1039/d4an00121d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/09/2024]
Abstract
Herein, we developed a gold nanoparticle (GNP)-mediated barcode qPCR strategy with a sensitivity for a single virus particle per reaction for the detection of influenza virus H3N2. The analysis of the results for pure virus and real virus samples show that GNP-mediated barcode qPCR is ∼16 times more sensitive than conventional qPCR, demonstrating the potential to reduce false negatives and improve early diagnosis of viral infections.
Collapse
Affiliation(s)
- Yuanzhao Shen
- College of Veterinary Medicine, Institute of Comparative Medicine, Joint International Research Laboratory of Agriculture and Agri-Product Safety, The Ministry of Education of China, Jiangsu Co-Innovation Center for Prevention and Control of Important Animal Infectious Diseases and Zoonoses, Yangzhou University, Yangzhou 225009, China.
| | - Chih-Tsung Yang
- Future Industries Institute, University of South Australia, Mawson Lakes Blvd, Mawson Lakes, South Australia 5095, Australia
| | - Weiwei Li
- Institute of Pediatrics, Children's Hospital of Fudan University, Fudan University, Shanghai 201102, China.
| | - Xin Zhou
- College of Veterinary Medicine, Institute of Comparative Medicine, Joint International Research Laboratory of Agriculture and Agri-Product Safety, The Ministry of Education of China, Jiangsu Co-Innovation Center for Prevention and Control of Important Animal Infectious Diseases and Zoonoses, Yangzhou University, Yangzhou 225009, China.
| |
Collapse
|
7
|
Léguillier V, Heddi B, Vidic J. Recent Advances in Aptamer-Based Biosensors for Bacterial Detection. BIOSENSORS 2024; 14:210. [PMID: 38785684 PMCID: PMC11117931 DOI: 10.3390/bios14050210] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/14/2024] [Revised: 04/09/2024] [Accepted: 04/19/2024] [Indexed: 05/25/2024]
Abstract
The rapid and sensitive detection of pathogenic bacteria is becoming increasingly important for the timely prevention of contamination and the treatment of infections. Biosensors based on nucleic acid aptamers, integrated with optical, electrochemical, and mass-sensitive analytical techniques, have garnered intense interest because of their versatility, cost-efficiency, and ability to exhibit high affinity and specificity in binding bacterial biomarkers, toxins, and whole cells. This review highlights the development of aptamers, their structural characterization, and the chemical modifications enabling optimized recognition properties and enhanced stability in complex biological matrices. Furthermore, recent examples of aptasensors for the detection of bacterial cells, biomarkers, and toxins are discussed. Finally, we explore the barriers to and discuss perspectives on the application of aptamer-based bacterial detection.
Collapse
Affiliation(s)
- Vincent Léguillier
- INRAE, AgroParisTech, Micalis Institut, Université Paris-Saclay, UMR 1319, 78350 Jouy-en-Josas, France;
- ENS Paris-Saclay, Laboratoire de Biologie et Pharmacologie Appliquée (LBPA), UMR8113 CNRS, 91190 Gif-sur-Yvette, France
| | - Brahim Heddi
- ENS Paris-Saclay, Laboratoire de Biologie et Pharmacologie Appliquée (LBPA), UMR8113 CNRS, 91190 Gif-sur-Yvette, France
| | - Jasmina Vidic
- INRAE, AgroParisTech, Micalis Institut, Université Paris-Saclay, UMR 1319, 78350 Jouy-en-Josas, France;
| |
Collapse
|
8
|
Valerio TL, Anastácio R, da Silva SS, de Oliveira CC, Vidotti M. An overview of electrochemical biosensors used for COVID-19 detection. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2024; 16:2164-2176. [PMID: 38536084 DOI: 10.1039/d3ay02042h] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/19/2024]
Abstract
This short review presents the latest advances in the field of electrochemical biosensors, focusing particularly on impedimetric biosensors for the direct measurement of analytes. As a source of study we have chosen to describe these advances in the latest global health crisis originated from the COVID-19 pandemic, initiated by the SARS-CoV-2 virus. In this period, the necessity for swift and precise detection methods has grown rapidly due to an imminent need for the development of an analytical method to identify and isolate infected patients as an attempt to control the spreading of the disease. Traditional approaches such as the enzyme-linked immunosorbent assay (ELISA), were extensively used during the SARS-CoV-2 pandemic, but their drawbacks, including slow response time, became evident. In this context, the potential of electrochemical biosensors as an alternative for COVID-19 detection was emphasized. These biosensors merge electrochemical technology with bioreceptors, offering benefits such as rapidity, accuracy, portability, and real-time result provision. Additionally, we present instances of electrochemical biosensors modified with conductive polymers, eliminating the necessity for an electrochemical probe. The adaptability of the developed materials and devices facilitated the prompt production of electrochemical biosensors during the pandemic, creating opportunities for broader applications in infectious disease diagnosis.
Collapse
Affiliation(s)
- Tatiana Lima Valerio
- Grupo de Pesquisa em Macromoléculas e Interfaces, Universidade Federal Do Paraná (UFPR), 81531-980, Curitiba, PR, Brazil.
| | - Raquel Anastácio
- Grupo de Pesquisa em Macromoléculas e Interfaces, Universidade Federal Do Paraná (UFPR), 81531-980, Curitiba, PR, Brazil.
| | - Stella Schuster da Silva
- Laboratório de Células Inflamatórias e Neoplásicas (LCIN) e Laboratório de Investigação de Polissacarídeos Sulfatados (LIPS), Universidade Federal Do Paraná (UFPR), 81531-980, Curitiba, PR, Brazil
| | - Carolina Camargo de Oliveira
- Laboratório de Células Inflamatórias e Neoplásicas (LCIN) e Laboratório de Investigação de Polissacarídeos Sulfatados (LIPS), Universidade Federal Do Paraná (UFPR), 81531-980, Curitiba, PR, Brazil
| | - Marcio Vidotti
- Grupo de Pesquisa em Macromoléculas e Interfaces, Universidade Federal Do Paraná (UFPR), 81531-980, Curitiba, PR, Brazil.
| |
Collapse
|
9
|
Lu Y, Ning Y, Li B, Liu B. Dual-Signal Imaging Mode Based on Fluorescence and Electrochemiluminescence for Ultrasensitive Visualization of SARS-CoV-2 Spike Protein. Anal Chem 2024; 96:463-470. [PMID: 38116596 DOI: 10.1021/acs.analchem.3c04535] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2023]
Abstract
Accurate and reliable detection of SARS-CoV-2 is critical for the effective prevention and rapid containment of COVID-19. Current approaches suffer from complex procedures or a single signal readout, resulting in an increased risk of false negatives and low sensitivity. Here, we developed a fluorescence (FL) and electrochemiluminescence (ECL) dual-mode imaging platform based on a self-powered DNAzyme walker to achieve accurate surveillance of SARS-CoV-2 spike protein at the single-molecule level. The specific activation of the DNAzyme walker by the target protein provides the power for the system's continuous running, enabling the simultaneous recording of the reduction in fluorescence spots and the appearance of ECL spots generated by the Ru-doped metal-organic framework (MOF) emitter. Therefore, the constructed imaging platform can achieve dual-mode detection of spike protein via reverse dual-signal feedback, which could effectively eliminate false-positive or false-negative signals and improve the detection accuracy and sensitivity with a low detection limit. In particular, the dual-mode accuracy of spike protein diagnosis in samples has been significantly improved compared to single-signal output means. In addition, this dual-mode imaging platform may become a prospective diagnostic device for other infectious viruses.
Collapse
Affiliation(s)
- Yanwei Lu
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers, Institutes of Biomedical Sciences, Fudan University, Shanghai 200438, China
| | - Yujun Ning
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers, Institutes of Biomedical Sciences, Fudan University, Shanghai 200438, China
| | - Binxiao Li
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers, Institutes of Biomedical Sciences, Fudan University, Shanghai 200438, China
| | - Baohong Liu
- Department of Chemistry, Shanghai Stomatological Hospital, State Key Laboratory of Molecular Engineering of Polymers, Institutes of Biomedical Sciences, Fudan University, Shanghai 200438, China
| |
Collapse
|
10
|
Lin C, Liu Z, Fang F, Zhao S, Li Y, Xu M, Peng Y, Chen H, Yuan F, Zhang W, Zhang X, Teng Z, Xiao R, Yang Y. Next-Generation Rapid and Ultrasensitive Lateral Flow Immunoassay for Detection of SARS-CoV-2 Variants. ACS Sens 2023; 8:3733-3743. [PMID: 37675933 DOI: 10.1021/acssensors.3c01019] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/08/2023]
Abstract
The coronavirus disease 2019 (COVID-19) pandemic highlighted the need for rapid and accurate viral detection at the point-of-care testing (POCT). Compared with nucleic acid detection, lateral flow immunoassay (LFIA) is a rapid and flexible method for POCT detection. However, the sensitivity of LFIA limits its use for early identification of patients with COVID-19. Here, an innovative surface-enhanced Raman scattering (SERS)-LFIA platform based on two-dimensional black phosphorus decorated with Ag nanoparticles as important antigen-capturing and Raman-signal-amplification unit was developed for detection of SARS-CoV-2 variants within 5-20 min. The novel SERS-LFIA platform realized a limit of detection of 0.5 pg/mL and 100 copies/mL for N protein and SARS-CoV-2, demonstrating 1000 times more sensitivity than the commercial LFIA strips. It could reliably detect seven different SARS-CoV-2 variants with cycle threshold (Ct) < 38, with sensitivity and specificity of 97 and 100%, respectively, exhibiting the same sensitivity with q-PCR. Furthermore, the detection results for 48 SARS-CoV-2-positive nasopharyngeal swabs (Ct = 19.8-38.95) and 96 negative nasopharyngeal swabs proved the reliability of the strips in clinical application. The method also had good specificity in double-blind experiments involving several other coronaviruses, respiratory viruses, and respiratory medications. The results showed that the innovative SERS-LFIA platform is expected to be the next-generation antigen detection technology. The inexpensive amplification-free assay combines the advantages of rapid low-cost POCT and highly sensitive nucleic acid detection, and it is suitable for rapid detection of SARS-CoV-2 variants and other pathogens. Thus, it could replace existing antigens and nucleic acids to some extent.
Collapse
Affiliation(s)
- Chenglong Lin
- State Key Laboratory of High-Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050, People's Republic of China
- Graduate School of the Chinese Academy of Sciences, No.19(A) Yuquan Road, Beijing 100049, People's Republic of China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
| | - Zhenzhen Liu
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, No.20 Dongdajie, Fengtai District, Beijing 100101, People's Republic of China
| | - Fanghao Fang
- Shanghai Municipal Centre for Disease Control and Prevention, No. 1380, Zhongshan West Road, Shanghai 200336, People's Republic of China
| | - Shuai Zhao
- State Key Laboratory of High-Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050, People's Republic of China
- Graduate School of the Chinese Academy of Sciences, No.19(A) Yuquan Road, Beijing 100049, People's Republic of China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
| | - Yanyan Li
- State Key Laboratory of High-Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050, People's Republic of China
- Graduate School of the Chinese Academy of Sciences, No.19(A) Yuquan Road, Beijing 100049, People's Republic of China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
| | - Meimei Xu
- State Key Laboratory of High-Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050, People's Republic of China
- Graduate School of the Chinese Academy of Sciences, No.19(A) Yuquan Road, Beijing 100049, People's Republic of China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
| | - Yusi Peng
- State Key Laboratory of High-Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050, People's Republic of China
- Graduate School of the Chinese Academy of Sciences, No.19(A) Yuquan Road, Beijing 100049, People's Republic of China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
| | - Hongyou Chen
- Shanghai Municipal Centre for Disease Control and Prevention, No. 1380, Zhongshan West Road, Shanghai 200336, People's Republic of China
| | - Fang Yuan
- Shanghai Municipal Centre for Disease Control and Prevention, No. 1380, Zhongshan West Road, Shanghai 200336, People's Republic of China
| | - Wanju Zhang
- Shanghai Municipal Centre for Disease Control and Prevention, No. 1380, Zhongshan West Road, Shanghai 200336, People's Republic of China
| | - Xi Zhang
- Shanghai Municipal Centre for Disease Control and Prevention, No. 1380, Zhongshan West Road, Shanghai 200336, People's Republic of China
| | - Zheng Teng
- Shanghai Municipal Centre for Disease Control and Prevention, No. 1380, Zhongshan West Road, Shanghai 200336, People's Republic of China
| | - Rui Xiao
- State Key Laboratory of Pathogen and Biosecurity, Beijing Institute of Microbiology and Epidemiology, No.20 Dongdajie, Fengtai District, Beijing 100101, People's Republic of China
| | - Yong Yang
- State Key Laboratory of High-Performance Ceramics and Superfine Microstructures, Shanghai Institute of Ceramics, Chinese Academy of Sciences, 1295 Dingxi Road, Shanghai 200050, People's Republic of China
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, People's Republic of China
| |
Collapse
|
11
|
Uzunoglu A, Gunes Altuntas E, Huseyin Ipekci H, Ozoglu O. Two-Dimensional (2D) materials in the detection of SARS-CoV-2. Microchem J 2023; 193:108970. [PMID: 37342763 PMCID: PMC10265934 DOI: 10.1016/j.microc.2023.108970] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/20/2023] [Revised: 06/10/2023] [Accepted: 06/10/2023] [Indexed: 06/23/2023]
Abstract
The SARS-CoV-2 pandemic has resulted in a devastating effect on human health in the last three years. While tremendous effort has been devoted to the development of effective treatment and vaccines against SARS-CoV-2 and controlling the spread of it, collective health challenges have been encountered along with the concurrent serious economic impacts. Since the beginning of the pandemic, various detection methods like PCR-based methods, isothermal nucleic acid amplification-based (INAA) methods, serological methods or antibody tests, and evaluation of X-ray chest results have been exploited to diagnose SARS-CoV-2. PCR-based detection methods in these are considered gold standards in the current stage despite their drawbacks, including being high-cost and time-consuming procedures. Furthermore, the results obtained from the PCR tests are susceptible to sample collection methods and time. When the sample is not collected properly, obtaining a false result may be likely. The use of specialized lab equipment and the need for trained people for the experiments pose additional challenges in PCR-based testing methods. Also, similar problems are observed in other molecular and serological methods. Therefore, biosensor technologies are becoming advantageous with their quick response, high specificity and precision, and low-cost characteristics for SARS-CoV-2 detection. In this paper, we critically review the advances in the development of sensors for the detection of SARS-CoV-2 using two-dimensional (2D) materials. Since 2D materials including graphene and graphene-related materials, transition metal carbides, carbonitrides, and nitrides (MXenes), and transition metal dichalcogenides (TMDs) play key roles in the development of novel and high-performance electrochemical (bio)sensors, this review pushes the sensor technologies against SARS-CoV-2 detection forward and highlights the current trends. First, the basics of SARS-CoV-2 detection are described. Then the structure and the physicochemical properties of the 2D materials are explained, which is followed by the development of SARS-CoV-2 sensors by exploiting the exceptional properties of the 2D materials. This critical review covers most of the published papers in detail from the beginning of the outbreak.
Collapse
Affiliation(s)
- Aytekin Uzunoglu
- Faculty of Engineering, Metallurgical & Materials Engineering, Necmettin Erbakan University, Konya 42090, Turkey
| | - Evrim Gunes Altuntas
- Ankara University, Biotechnology Institute, Gumusdere Campus, 06135, Ankara, Turkey
| | - Hasan Huseyin Ipekci
- Faculty of Engineering, Metallurgical & Materials Engineering, Necmettin Erbakan University, Konya 42090, Turkey
| | - Ozum Ozoglu
- Department of Food Engineering, Faculty of Agriculture, Bursa Uludag University, 16059 Bursa, Turkey
| |
Collapse
|
12
|
Aloraij Y, Suaifan GARY, Shibl A, Al-Kattan K, Zourob MM. Development of Rapid Aptamer-Based Screening Assay for the Detection of Covid-19 Variants. ACS OMEGA 2023; 8:32877-32883. [PMID: 37720766 PMCID: PMC10500687 DOI: 10.1021/acsomega.3c04137] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/11/2023] [Accepted: 08/16/2023] [Indexed: 09/19/2023]
Abstract
The development of a colorimetric severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) detection assay with the WHO published ASSURED criteria is reported, in which the biosensor should have the following characteristics of (i) being affordable for low-income communities, (ii) sensitive, (iii) specific, (iv) user-friendly to be used by non-skilled personnel, (v) rapid and robust, (vi) equipment-free, and (vii) delivered to the end-users as a simple and easy to use point-of-care tool. Early viral infection detection prevents virus spread and controls the epidemic. We herein report the development of a colorimetric assay in which SARS-COV-2 variants can be detected by colorimetric observation of color on the sensing cotton swab surface. Using the developed biosensor assay, it is possible to discriminate between the various SARS-CoV-2 variants with a LOD of 100 ng/mL within 4 min including sample preconcentration and incubation step. The results illustrated the development of a SARS-CoV-2 colorimetric biosensor that can be mass produced, with low-reagent cost, and can be read-out visually in the field by nonskilled personnel.
Collapse
Affiliation(s)
- Yumna
M. Aloraij
- Department
of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi
Rd, Riyadh 11533, Saudi Arabia
| | - Ghadeer A. R. Y. Suaifan
- Department
of Pharmaceutical Sciences, Faculty of Pharmacy, The University of Jordan, Amman 11942, Jordan
| | - Atef Shibl
- College
of Medicine, Alfaisal University, Al Zahrawi Street, Al Maather, Al
Takhassusi Rd, Riyadh 11533, Saudi Arabia
| | - Khaled Al-Kattan
- College
of Medicine, Alfaisal University, Al Zahrawi Street, Al Maather, Al
Takhassusi Rd, Riyadh 11533, Saudi Arabia
| | - Mohammed M. Zourob
- Department
of Chemistry, Alfaisal University, Al Zahrawi Street, Al Maather, AlTakhassusi
Rd, Riyadh 11533, Saudi Arabia
| |
Collapse
|
13
|
Tsounidi D, Angelopoulou M, Petrou P, Raptis I, Kakabakos S. Simultaneous Detection of SARS-CoV-2 Nucleoprotein and Receptor Binding Domain by a Multi-Area Reflectance Spectroscopy Sensor. BIOSENSORS 2023; 13:865. [PMID: 37754099 PMCID: PMC10526254 DOI: 10.3390/bios13090865] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/04/2023] [Revised: 08/22/2023] [Accepted: 08/30/2023] [Indexed: 09/28/2023]
Abstract
The COVID-19 pandemic has emphasized the urgent need for point-of-care methods suitable for the rapid and reliable diagnosis of viral infections. To address this demand, we report the rapid, label-free simultaneous determination of two SARS-CoV-2 proteins, namely, the nucleoprotein and the receptor binding domain peptide of S1 protein, by implementing a bioanalytical device based on Multi Area Reflectance Spectroscopy. Simultaneous detection of these two proteins is achieved by using silicon chips with adjacent areas of different silicon dioxide thickness on top, each of which is modified with an antibody specific to either the nucleoprotein or the receptor binding domain of SARS-CoV-2. Both areas were illuminated by a single probe that also collected the reflected light, directing it to a spectrometer. The online conversion of the combined reflection spectra from the two silicon dioxide areas into the respective adlayer thickness enabled real-time monitoring of immunoreactions taking place on the two areas. Several antibodies have been tested to define the pair, providing the higher specific signal following a non-competitive immunoassay format. Biotinylated secondary antibodies and streptavidin were used to enhance the specific signal. Both proteins were detected in less than 12 min, with detection limits of 1.0 ng/mL. The assays demonstrated high repeatability with intra- and inter-assay coefficients of variation lower than 10%. Moreover, the recovery of both proteins from spiked samples prepared in extraction buffer from a commercial self-test kit for SARS-CoV-2 collection from nasopharyngeal swabs ranged from 90.0 to 110%. The short assay duration in combination with the excellent analytical performance and the compact instrument size render the proposed device and assay suitable for point-of-care applications.
Collapse
Affiliation(s)
- Dimitra Tsounidi
- Immunoassays-Immunosensors Lab, Institute of Nuclear and Radiological Sciences and Technology, Energy and Safety, NCSR “Demokritos”, 15341 Aghia Paraskevi, Greece; (D.T.); (M.A.); (P.P.)
| | - Michailia Angelopoulou
- Immunoassays-Immunosensors Lab, Institute of Nuclear and Radiological Sciences and Technology, Energy and Safety, NCSR “Demokritos”, 15341 Aghia Paraskevi, Greece; (D.T.); (M.A.); (P.P.)
| | - Panagiota Petrou
- Immunoassays-Immunosensors Lab, Institute of Nuclear and Radiological Sciences and Technology, Energy and Safety, NCSR “Demokritos”, 15341 Aghia Paraskevi, Greece; (D.T.); (M.A.); (P.P.)
| | - Ioannis Raptis
- Institute of Nanoscience and Nanotechnology, NCSR “Demokritos”, 15341 Aghia Paraskevi, Greece;
| | - Sotirios Kakabakos
- Immunoassays-Immunosensors Lab, Institute of Nuclear and Radiological Sciences and Technology, Energy and Safety, NCSR “Demokritos”, 15341 Aghia Paraskevi, Greece; (D.T.); (M.A.); (P.P.)
| |
Collapse
|
14
|
Laleh S, Ibarlucea B, Stadtmüller M, Cuniberti G, Medina-Sánchez M. Portable microfluidic impedance biosensor for SARS-CoV-2 detection. Biosens Bioelectron 2023; 236:115362. [PMID: 37300901 DOI: 10.1016/j.bios.2023.115362] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2023] [Revised: 04/24/2023] [Accepted: 04/27/2023] [Indexed: 06/12/2023]
Abstract
Pandemics as the one we are currently facing, where fast-spreading viruses present a threat to humanity, call for simple and reliable methods to perform early diagnosis, enabling detection of very low pathogen loads even before symptoms start showing in the host. So far, standard polymerase chain reaction (PCR) is the most reliable method for doing so, but it is rather slow and needs specialized reagents and trained personnel to operate it. Additionally, it is expensive and not easily accessible. Therefore, developing miniaturized and portable sensors which perform early detection of pathogens with high reliability is necessary to not only prevent the spreading of the disease but also to monitor the effectiveness of the developed vaccines and the appearance of new pathogenic variants. Thus, in this work we develop a sensitive microfluidic impedance biosensor for the direct detection of SARS-CoV-2, towards a mobile point-of-care (POC) platform. The operational parameters are optimized with the aid of design-of-experiment (DoE), for an accurate detection of the viral antigens using electrochemical impedance spectroscopy (EIS). We perform the biodetection of buffer samples spiked with fM concentration levels and validate the biosensor in a clinical context of relevance by analyzing 15 real patient samples up to a Ct value (cycle threshold) of 27. Finally, we demonstrate the versatility of the developed platform using different settings, including a small portable potentiostat, using multiple channels for self-validation, as well as with single biosensors for a smartphone-based readout. This work contributes to the rapid and reliable diagnostics of COVID-19 and can be extended to other infectious diseases, allowing the monitoring of viral load in vaccinated and unvaccinated people to anticipate a potential relapse of the disease.
Collapse
Affiliation(s)
- Soroush Laleh
- Micro- and NanoBiomedical Engineering Group (MNBE), Institute for Emerging Electronic Technologies, Leibniz Institute for Solid State and Materials Research (Leibniz IFW Dresden), 01069, Dresden, Germany; Chair of Micro- and NanoSystems, Center for Molecular Bioengineering (B CUBE), Dresden University of Technology, 01062, Dresden, Germany
| | - Bergoi Ibarlucea
- Institute for Materials Science and Max Bergmann Center for Biomaterials, Dresden University of Technology, Dresden, Germany.
| | | | - Gianaurelio Cuniberti
- Institute for Materials Science and Max Bergmann Center for Biomaterials, Dresden University of Technology, Dresden, Germany; Dresden Center for Computational Materials Science (DCMS), Dresden University of Technology, Dresden, Germany
| | - Mariana Medina-Sánchez
- Micro- and NanoBiomedical Engineering Group (MNBE), Institute for Emerging Electronic Technologies, Leibniz Institute for Solid State and Materials Research (Leibniz IFW Dresden), 01069, Dresden, Germany; Chair of Micro- and NanoSystems, Center for Molecular Bioengineering (B CUBE), Dresden University of Technology, 01062, Dresden, Germany.
| |
Collapse
|
15
|
Yu Q, Trinh HD, Lee Y, Kang T, Chen L, Yoon S, Choo J. SERS-ELISA using silica-encapsulated Au core-satellite nanotags for sensitive detection of SARS-CoV-2. SENSORS AND ACTUATORS. B, CHEMICAL 2023; 382:133521. [PMID: 36818494 PMCID: PMC9927800 DOI: 10.1016/j.snb.2023.133521] [Citation(s) in RCA: 16] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 01/30/2023] [Accepted: 02/13/2023] [Indexed: 06/12/2023]
Abstract
The sensitive detection of viruses is key to preventing the spread of infectious diseases. In this study, we develop a silica-encapsulated Au core-satellite (CS@SiO2) nanotag, which produces a strong and reproducible surface-enhanced Raman scattering (SERS) signal. The combination of SERS from the CS@SiO2 nanotags with enzyme-linked immunosorbent assay (ELISA) achieves a highly sensitive detection of SARS-CoV-2. The CS@SiO2 nanotag is constructed by assembling 32 nm Au nanoparticles (AuNPs) on a 75 nm AuNP. Then the core-satellite particles are encapsulated with SiO2 for facile surface modification and stability. The SERS-ELISA technique using the CS@SiO2 nanotags provides a great sensitivity, yielding a detection limit of 8.81 PFU mL-1, which is 10 times better than conventional ELISA and 100 times better than lateral flow assay strip method. SERS-ELISA is applied to 30 SARS-CoV-2 clinical samples and achieved 100% and 55% sensitivities for 15 and 9 positive samples with cycle thresholds < 30 and > 30, respectively. This new CS@SiO2-SERS-ELISA method is an innovative technique that can significantly reduce the false-negative diagnostic rate for SARS-CoV-2 and thereby contribute to overcoming the current pandemic crisis.
Collapse
Affiliation(s)
- Qian Yu
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea
| | - Hoa Duc Trinh
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea
| | - Yeonji Lee
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea
| | - Taejoon Kang
- Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon 34141, South Korea
- School of Pharmacy, Sungkyunkwan University, Suwon 16419, South Korea
| | - Lingxin Chen
- Key Laboratory of Coastal Environmental Processes and Ecological Remediation, Yantai Institute of Coastal Zone Research, Chinese Academy of Sciences, Yantai 264003, China
| | - Sangwoon Yoon
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea
| | - Jaebum Choo
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea
| |
Collapse
|
16
|
Chen S, Sun Y, Fan X, Xu Y, Chen S, Zhang X, Man B, Yang C, Du J. Review on two-dimensional material-based field-effect transistor biosensors: accomplishments, mechanisms, and perspectives. J Nanobiotechnology 2023; 21:144. [PMID: 37122015 PMCID: PMC10148958 DOI: 10.1186/s12951-023-01898-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Accepted: 04/16/2023] [Indexed: 05/02/2023] Open
Abstract
Field-effect transistor (FET) is regarded as the most promising candidate for the next-generation biosensor, benefiting from the advantages of label-free, easy operation, low cost, easy integration, and direct detection of biomarkers in liquid environments. With the burgeoning advances in nanotechnology and biotechnology, researchers are trying to improve the sensitivity of FET biosensors and broaden their application scenarios from multiple strategies. In order to enable researchers to understand and apply FET biosensors deeply, focusing on the multidisciplinary technical details, the iteration and evolution of FET biosensors are reviewed from exploring the sensing mechanism in detecting biomolecules (research direction 1), the response signal type (research direction 2), the sensing performance optimization (research direction 3), and the integration strategy (research direction 4). Aiming at each research direction, forward perspectives and dialectical evaluations are summarized to enlighten rewarding investigations.
Collapse
Affiliation(s)
- Shuo Chen
- School of Physics and Electronics, Shandong Normal University, Jinan, 250014, People's Republic of China
| | - Yang Sun
- Beijing Key Laboratory for Bioengineering and Sensing Technology, School of Chemistry and Biological Engineering, University of Science and Technology, 30 Xueyuan Road, Haidian District, Beijing, 100083, People's Republic of China
| | - Xiangyu Fan
- School of Physics and Electronics, Shandong Normal University, Jinan, 250014, People's Republic of China
| | - Yazhe Xu
- School of Physics and Electronics, Shandong Normal University, Jinan, 250014, People's Republic of China
| | - Shanshan Chen
- School of Physics and Electronics, Shandong Normal University, Jinan, 250014, People's Republic of China
| | - Xinhao Zhang
- School of Physics and Electronics, Shandong Normal University, Jinan, 250014, People's Republic of China
| | - Baoyuan Man
- School of Physics and Electronics, Shandong Normal University, Jinan, 250014, People's Republic of China
| | - Cheng Yang
- School of Physics and Electronics, Shandong Normal University, Jinan, 250014, People's Republic of China.
| | - Jun Du
- School of Physics and Electronics, Shandong Normal University, Jinan, 250014, People's Republic of China.
| |
Collapse
|
17
|
Jiang C, Mu X, Liu S, Liu Z, Liu B, Du B, Tong Z. A Study of the Detection of SARS-CoV-2 by the Use of Electrochemiluminescent Biosensor Based on Asymmetric Polymerase Chain Reaction Amplification Strategy. IEEE SENSORS JOURNAL 2023; 23:8094-8100. [PMID: 37216192 PMCID: PMC10168129 DOI: 10.1109/jsen.2022.3201507] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 05/29/2022] [Revised: 07/27/2022] [Accepted: 08/20/2022] [Indexed: 05/24/2023]
Abstract
A new and reliable method has been constructed for detecting severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) open reading frames 1ab (ORF1ab) gene via highly sensitive electrochemiluminescence (ECL) biosensor technology based on highly efficient asymmetric polymerase chain reaction (asymmetric PCR) amplification strategy. This method uses magnetic particles coupled with biotin-labeled one complementary nucleic acid sequence of the SARS-CoV-2 ORF1ab gene as the magnetic capture probes, and [Formula: see text]-labeled amino-modified another complementary nucleic acid sequence as the luminescent probes, and then a detection model of magnetic capture probes-asymmetric PCR amplification nucleic acid products-[Formula: see text]-labeled luminescent probes is formed, which combines the advantages of highly efficient asymmetric PCR amplification strategy and highly sensitive ECL biosensor technology, enhancing the method sensitivity of detecting the SARS-CoV-2 ORF1ab gene. The method enables the rapid and sensitive detection of the ORF1ab gene and has a linear range of 1-[Formula: see text] copies/[Formula: see text], a regression equation of [Formula: see text] = [Formula: see text] + 2919.301 ([Formula: see text] = 0.9983, [Formula: see text] = 7), and a limit of detection (LOD) of 1 copy/[Formula: see text]. In summary, it can meet the analytical requirements for simulated saliva and urine samples and has the benefits of easy operation, reasonable reproducibility, high sensitivity, and anti-interference abilities, which can provide a reference for developing efficient field detection methods for SARS-CoV-2.
Collapse
Affiliation(s)
- Chunying Jiang
- State Key Laboratory of NBC Protection for CivilianBeijing102205China
| | - Xihui Mu
- State Key Laboratory of NBC Protection for CivilianBeijing102205China
| | - Shuai Liu
- State Key Laboratory of NBC Protection for CivilianBeijing102205China
| | - Zhiwei Liu
- State Key Laboratory of NBC Protection for CivilianBeijing102205China
| | - Bing Liu
- State Key Laboratory of NBC Protection for CivilianBeijing102205China
| | - Bin Du
- State Key Laboratory of NBC Protection for CivilianBeijing102205China
| | - Zhaoyang Tong
- State Key Laboratory of NBC Protection for CivilianBeijing102205China
| |
Collapse
|
18
|
Chen H, Hou ZY, Chen D, Li T, Wang YM, De Lima MA, Yang Y, Guo ZZ. Highly Sensitive Poly-N-isopropylacrylamide Microgel-based Electrochemical Biosensor for the Detection of SARS-COV-2 Spike Protein. BIOMEDICAL AND ENVIRONMENTAL SCIENCES : BES 2023; 36:269-278. [PMID: 37005080 PMCID: PMC10080711 DOI: 10.3967/bes2023.029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Subscribe] [Scholar Register] [Received: 10/20/2022] [Accepted: 10/27/2022] [Indexed: 06/19/2023]
Abstract
Objective Late 2019 witnessed the outbreak and widespread transmission of coronavirus disease 2019 (COVID-19), a new, highly contagious disease caused by novel severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Consequently, considerable attention has been paid to the development of new diagnostic tools for the early detection of SARS-CoV-2. Methods In this study, a new poly-N-isopropylacrylamide microgel-based electrochemical sensor was explored to detect the SARS-CoV-2 spike protein (S protein) in human saliva. The microgel was composed of a copolymer of N-isopropylacrylamide and acrylic acid, and gold nanoparticles were encapsulated within the microgel through facile and economical fabrication. The electrochemical performance of the sensor was evaluated through differential pulse voltammetry. Results Under optimal experimental conditions, the linear range of the sensor was 10 -13-10 -9 mg/mL, whereas the detection limit was 9.55 fg/mL. Furthermore, the S protein was instilled in artificial saliva as the infected human saliva model, and the sensing platform showed satisfactory detection capability. Conclusion The sensing platform exhibited excellent specificity and sensitivity in detecting spike protein, indicating its potential application for the time-saving and inexpensive detection of SARS-CoV-2.
Collapse
Affiliation(s)
- Hao Chen
- Department of Anaesthesiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, Hubei, China
| | - Zhi Yuan Hou
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, Wuhan University of Science and Technology, Wuhan 430065, Hubei, China;Department of Pharmacy, Medical College, Wuhan University of Science and Technology Wuhan 430065, Hubei, China
| | - Die Chen
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, Wuhan University of Science and Technology, Wuhan 430065, Hubei, China;Department of Pharmacy, Medical College, Wuhan University of Science and Technology Wuhan 430065, Hubei, China
| | - Ting Li
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, Wuhan University of Science and Technology, Wuhan 430065, Hubei, China;Department of Pharmacy, Medical College, Wuhan University of Science and Technology Wuhan 430065, Hubei, China
| | - Yi Ming Wang
- School of Public Health, Medical College, Wuhan University of Science and Technology Wuhan 430065, Hubei, China
| | | | - Ying Yang
- School of Pharmacy and Bioengineering, Keele University, Staffordshire ST4 7QB, UK
| | - Zhen Zhong Guo
- Hubei Province Key Laboratory of Occupational Hazard Identification and Control, Wuhan University of Science and Technology, Wuhan 430065, Hubei, China
| |
Collapse
|
19
|
Popescu M, Ungureanu C. Biosensors in Food and Healthcare Industries: Bio-Coatings Based on Biogenic Nanoparticles and Biopolymers. COATINGS 2023; 13:486. [DOI: 10.3390/coatings13030486] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
Abstract
Biosensors use biological materials, such as enzymes, antibodies, or DNA, to detect specific analytes. These devices have numerous applications in the health and food industries, such as disease diagnosis, food safety monitoring, and environmental monitoring. However, the production of biosensors can result in the generation of chemical waste, which is an environmental concern for the developed world. To address this issue, researchers have been exploring eco-friendly alternatives for immobilising biomolecules on biosensors. One solution uses bio-coatings derived from nanoparticles synthesised via green chemistry and biopolymers. These materials offer several advantages over traditional chemical coatings, such as improved sensitivity, stability, and biocompatibility. In conclusion, the use of bio-coatings derived from green-chemistry synthesised nanoparticles and biopolymers is a promising solution to the problem of chemical waste generated from the production of biosensors. This review provides an overview of these materials and their applications in the health and food industries, highlighting their potential to improve the performance and sustainability of biosensors.
Collapse
Affiliation(s)
- Melania Popescu
- National Institute for Research and Development in Microtechnologies—IMT Bucharest, 126A Erou Iancu Nicolae Street, 077190 Bucharest, Romania
| | - Camelia Ungureanu
- General Chemistry Department, University “Politehnica” of Bucharest, Gheorghe Polizu Street, 1-7, 011061 Bucharest, Romania
| |
Collapse
|
20
|
Yang Y, Li H, Jones L, Murray J, Haverstick J, Naikare HK, Mosley YYC, Tripp RA, Ai B, Zhao Y. Rapid Detection of SARS-CoV-2 RNA in Human Nasopharyngeal Specimens Using Surface-Enhanced Raman Spectroscopy and Deep Learning Algorithms. ACS Sens 2023; 8:297-307. [PMID: 36563081 PMCID: PMC9797020 DOI: 10.1021/acssensors.2c02194] [Citation(s) in RCA: 18] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2022] [Accepted: 12/14/2022] [Indexed: 12/24/2022]
Abstract
A rapid and cost-effective method to detect the infection of SARS-CoV-2 is fundamental to mitigating the current COVID-19 pandemic. Herein, a surface-enhanced Raman spectroscopy (SERS) sensor with a deep learning algorithm has been developed for the rapid detection of SARS-CoV-2 RNA in human nasopharyngeal swab (HNS) specimens. The SERS sensor was prepared using a silver nanorod array (AgNR) substrate by assembling DNA probes to capture SARS-CoV-2 RNA. The SERS spectra of HNS specimens were collected after RNA hybridization, and the corresponding SERS peaks were identified. The RNA detection range was determined to be 103-109 copies/mL in saline sodium citrate buffer. A recurrent neural network (RNN)-based deep learning model was developed to classify 40 positive and 120 negative specimens with an overall accuracy of 98.9%. For the blind test of 72 specimens, the RNN model gave a 97.2% accuracy prediction for positive specimens and a 100% accuracy for negative specimens. All the detections were performed in 25 min. These results suggest that the DNA-functionalized AgNR array SERS sensor combined with a deep learning algorithm could serve as a potential rapid point-of-care COVID-19 diagnostic platform.
Collapse
Affiliation(s)
- Yanjun Yang
- School of Electrical and Computer Engineering, College
of Engineering, The University of Georgia, Athens,
Georgia30602, United States
| | - Hao Li
- School of Microelectronics and Communication
Engineering, Chongqing Key Laboratory of Bio-perception & Intelligent Information
Processing, Chongqing University, Chongqing400044, P.
R. China
| | - Les Jones
- Department of Infectious Diseases, College of Veterinary
Medicine, The University of Georgia, Athens, Georgia30602,
United States
| | - Jackelyn Murray
- Department of Infectious Diseases, College of Veterinary
Medicine, The University of Georgia, Athens, Georgia30602,
United States
| | - James Haverstick
- Department of Physics and Astronomy, The
University of Georgia, Athens, Georgia30602, United
States
| | - Hemant K. Naikare
- Department of Infectious Diseases, College of Veterinary
Medicine, The University of Georgia, Athens, Georgia30602,
United States
- Tifton Veterinary Diagnostic and Investigational
Laboratory, The University of Georgia, Athens, Georgia30602,
United States
| | - Yung-Yi C. Mosley
- Department of Infectious Diseases, College of Veterinary
Medicine, The University of Georgia, Athens, Georgia30602,
United States
- Tifton Veterinary Diagnostic and Investigational
Laboratory, The University of Georgia, Athens, Georgia30602,
United States
| | - Ralph A. Tripp
- Department of Infectious Diseases, College of Veterinary
Medicine, The University of Georgia, Athens, Georgia30602,
United States
| | - Bin Ai
- School of Microelectronics and Communication
Engineering, Chongqing Key Laboratory of Bio-perception & Intelligent Information
Processing, Chongqing University, Chongqing400044, P.
R. China
| | - Yiping Zhao
- Department of Physics and Astronomy, The
University of Georgia, Athens, Georgia30602, United
States
| |
Collapse
|
21
|
Gu MM, Guan PC, Xu SS, Li HM, Kou YC, Lin XD, Kathiresan M, Song Y, Zhang YJ, Jin SZ, Li JF. Ultrasensitive detection of SARS-CoV-2 S protein with aptamers biosensor based on surface-enhanced Raman scattering. J Chem Phys 2023; 158:024203. [PMID: 36641419 DOI: 10.1063/5.0130011] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
A rapid and accurate diagnostic modality is essential to prevent the spread of SARS-CoV-2. In this study, we proposed a SARS-CoV-2 detection sensor based on surface-enhanced Raman scattering (SERS) to achieve rapid and ultrasensitive detection. The sensor utilized spike protein deoxyribonucleic acid aptamers with strong affinity as the recognition entity to achieve high specificity. The spherical cocktail aptamers-gold nanoparticles (SCAP) SERS substrate was used as the base and Au nanoparticles modified with the Raman reporter molecule that resonates with the excitation light and spike protein aptamers were used as the SERS nanoprobe. The SCAP substrate and SERS nanoprobes were used to target and capture the SARS-CoV-2 S protein to form a sandwich structure on the Au film substrate, which can generate ultra-strong "hot spots" to achieve ultrasensitive detection. Analysis of SARS-CoV-2 S protein was performed by monitoring changes in SERS peak intensity on a SCAP SERS substrate-based detection platform. This assay detects S protein with a LOD of less than 0.7 fg mL-1 and pseudovirus as low as 0.8 TU mL-1 in about 12 min. The results of the simulated oropharyngeal swab system in this study indicated the possibility of it being used for clinical detection, providing a potential option for rapid and accurate diagnosis and more effective control of SARS-CoV-2 transmission.
Collapse
Affiliation(s)
- Man-Man Gu
- Key Laboratory for Modern Measurement Technology and Instruments of Zhejiang Province, China Jiliang University, Hangzhou 310018, China
| | - Peng-Cheng Guan
- State Key Laboratory for Physical Chemistry of Solid Surfaces, iChEM, MOE Key Laboratory of Spectrochemical Analysis and Instrumentation, College of Chemistry and Chemical Engineering, College of Energy, College of Materials, Xiamen University, Xiamen 361005, China
| | - Shan-Shan Xu
- State Key Laboratory for Physical Chemistry of Solid Surfaces, iChEM, MOE Key Laboratory of Spectrochemical Analysis and Instrumentation, College of Chemistry and Chemical Engineering, College of Energy, College of Materials, Xiamen University, Xiamen 361005, China
| | - Hong-Mei Li
- State Key Laboratory for Physical Chemistry of Solid Surfaces, iChEM, MOE Key Laboratory of Spectrochemical Analysis and Instrumentation, College of Chemistry and Chemical Engineering, College of Energy, College of Materials, Xiamen University, Xiamen 361005, China
| | - Yi-Chuan Kou
- State Key Laboratory for Physical Chemistry of Solid Surfaces, iChEM, MOE Key Laboratory of Spectrochemical Analysis and Instrumentation, College of Chemistry and Chemical Engineering, College of Energy, College of Materials, Xiamen University, Xiamen 361005, China
| | - Xiao-Dong Lin
- State Key Laboratory for Physical Chemistry of Solid Surfaces, iChEM, MOE Key Laboratory of Spectrochemical Analysis and Instrumentation, College of Chemistry and Chemical Engineering, College of Energy, College of Materials, Xiamen University, Xiamen 361005, China
| | - Murugavel Kathiresan
- Electro-Organic Division, CSIR-Central Electrochemical Research Institute, Karaikudi 630003, India
| | - Yanling Song
- State Key Laboratory for Physical Chemistry of Solid Surfaces, iChEM, MOE Key Laboratory of Spectrochemical Analysis and Instrumentation, College of Chemistry and Chemical Engineering, College of Energy, College of Materials, Xiamen University, Xiamen 361005, China
| | - Yue-Jiao Zhang
- State Key Laboratory for Physical Chemistry of Solid Surfaces, iChEM, MOE Key Laboratory of Spectrochemical Analysis and Instrumentation, College of Chemistry and Chemical Engineering, College of Energy, College of Materials, Xiamen University, Xiamen 361005, China
| | - Shang-Zhong Jin
- Key Laboratory for Modern Measurement Technology and Instruments of Zhejiang Province, China Jiliang University, Hangzhou 310018, China
| | - Jian-Feng Li
- Key Laboratory for Modern Measurement Technology and Instruments of Zhejiang Province, China Jiliang University, Hangzhou 310018, China
| |
Collapse
|
22
|
Singh CK, Sodhi KK. The emerging significance of nanomedicine-based approaches to fighting COVID-19 variants of concern: A perspective on the nanotechnology’s role in COVID-19 diagnosis and treatment. FRONTIERS IN NANOTECHNOLOGY 2023. [DOI: 10.3389/fnano.2022.1084033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023] Open
Abstract
COVID-19, one of the worst-hit pandemics, has quickly spread like fire across nations with very high mortality rates. Researchers all around the globe are making consistent efforts to address the main challenges faced due to COVID-19 infection including prompt diagnosis and therapeutics to reduce mortality. Conventional medical technology does not effectively contain the havoc caused by deadly COVID-19. This signals a crucial mandate for innovative and novel interventions in diagnostics and therapeutics to combat this ongoing pandemic and counter its successor or disease if it were ever to arise. The expeditious solutions can spring from promising areas such as nanomedicine and nanotechnology. Nanomedicine is a dominant tool that has a huge potential to alleviate the disease burden by providing nanoparticle-based vaccines and carriers. Nanotechnology encompasses multidisciplinary aspects including artificial intelligence, chemistry, biology, material science, physical science, and medicine. Nanoparticles offer many advantages compared to larger particles, including better magnetic properties and a multiplied surface-to-volume ratio. Given this, the present review focuses on promising nanomedicine-based solutions to combat COVID-19 and their utility to control a broad range of pathogens and viruses, along with understanding their role in the therapy, diagnosis, and prevention of COVID-19. Various studies, reports, and recent research and development from the nanotechnology perspective are discussed in this article.
Collapse
|
23
|
Zhu Z, Liang A, Haotian R, Tang S, Liu M, Xie B, Luo A. Application of Biosensors in the Detection of SARS-CoV-2. ACTA CHIMICA SINICA 2023. [DOI: 10.6023/a22120483] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/03/2023]
|
24
|
Ma T, Zhang J, Zhang L, Zhang Q, Xu X, Xiong Y, Ying Y, Fu Y. Recent advances in determination applications of emerging films based on nanomaterials. Adv Colloid Interface Sci 2023; 311:102828. [PMID: 36587470 DOI: 10.1016/j.cis.2022.102828] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2022] [Revised: 12/12/2022] [Accepted: 12/22/2022] [Indexed: 12/28/2022]
Abstract
Sensitive and facile detection of analytes is crucial in various fields such as agriculture production, food safety, clinical diagnosis and therapy, and environmental monitoring. However, the synergy of complicated sample pretreatment and detection is an urgent challenge. By integrating the inherent porosity, processability and flexibility of films and the diversified merits of nanomaterials, nanomaterial-based films have evolved as preferred candidates to meet the above challenge. Recent years have witnessed the flourishment of films-based detection technologies due to their unique porous structures and integrated physical/chemical merits, which favors the separation/collection and detection of analytes in a rapid, efficient and facile way. In particular, films based on nanomaterials consisting of 0D metal-organic framework particles, 1D nanofibers and carbon nanotubes, and 2D graphene and analogs have drawn increasing attention due to incorporating new properties from nanomaterials. This paper summarizes the progress of the fabrication of emerging films based on nanomaterials and their detection applications in recent five years, focusing on typical electrochemical and optical methods. Some new interesting applications, such as point-of-care testing, wearable devices and detection chips, are proposed and emphasized. This review will provide insights into the integration and processability of films based on nanomaterials, thus stimulate further contributions towards films based on nanomaterials for high-performance analytical-chemistry-related applications.
Collapse
Affiliation(s)
- Tongtong Ma
- College of Biosystems Engineering and Food Science, Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Zhejiang University, Hangzhou 310058, China
| | - Jie Zhang
- College of Biosystems Engineering and Food Science, Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Zhejiang University, Hangzhou 310058, China
| | - Lin Zhang
- College of Biosystems Engineering and Food Science, Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Zhejiang University, Hangzhou 310058, China
| | - Qi Zhang
- College of Biosystems Engineering and Food Science, Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Zhejiang University, Hangzhou 310058, China
| | - Xiahong Xu
- State Key Laboratory for Managing Biotic and Chemical Threats to the Quality and Safety of Agro-products, Institute of Agro-product Safety and Nutrition, Zhejiang Academy of Agricultural Sciences, Hangzhou 310021, China.
| | - Yonghua Xiong
- State Key Laboratory of Food Science and Technology, School of Food Science and Technology, Nanchang University, Nanchang 330047, China
| | - Yibin Ying
- College of Biosystems Engineering and Food Science, Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Zhejiang University, Hangzhou 310058, China
| | - Yingchun Fu
- College of Biosystems Engineering and Food Science, Key Laboratory of Intelligent Equipment and Robotics for Agriculture of Zhejiang Province, Zhejiang University, Hangzhou 310058, China.
| |
Collapse
|
25
|
Szczerska M, Wityk P, Listewnik P. The SARS-CoV-2 specific IgG antibodies biophotonic sensor. JOURNAL OF BIOPHOTONICS 2023; 16:e202200172. [PMID: 36222282 PMCID: PMC9874777 DOI: 10.1002/jbio.202200172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 09/23/2022] [Accepted: 09/28/2022] [Indexed: 06/16/2023]
Abstract
In this paper, we present the design and the principle of operation of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) specific immunoglobulin G (IgG) biophotonic sensor, which is based on the single-mode telecommunication fiber. We fabricated the sensor head at the face of the single mode fiber-28. Due to the process of bio-functionalization, our sensor has the ability to selectively detect the SARS-CoV-2 specific IgG antibodies. The results of preliminary tests allowed us to correctly determine the presence of antibodies in less than 1 min in 5 μl in a volume sample of concentration of 10 μg/ml, which according to studies, corresponds to the concentration of IgG antibodies in human serum. Additionally, the tested sample can be smaller than 5 μl in volume.
Collapse
Affiliation(s)
- Małgorzata Szczerska
- Department of Metrology and Optoelectronics, Faculty of Electronics, Telecommunications and InformaticsGdańsk University of TechnologyGdańskPoland
| | - Paweł Wityk
- Department of Biopharmaceutics and PharmacodynamicsMedical University of GdańskGdańskPoland
| | - Paulina Listewnik
- Department of Metrology and Optoelectronics, Faculty of Electronics, Telecommunications and InformaticsGdańsk University of TechnologyGdańskPoland
| |
Collapse
|
26
|
Pushpa S, Sukumaran RK, Savithri S. Robustness of FTIR-Based Ultrarapid COVID-19 Diagnosis Using PLS-DA. ACS OMEGA 2022; 7:47357-47371. [PMID: 36570187 PMCID: PMC9773962 DOI: 10.1021/acsomega.2c06786] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Accepted: 11/29/2022] [Indexed: 06/17/2023]
Abstract
The World Health Organization (WHO) declared the Omicron variant (B.1.1.529) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the pathogen responsible for the Coronavirus disease 2019 (COVID-19) pandemic, as a variant of concern on 26 November 2021. By this time, 42% of the world's population had received at least one dose of the vaccine against COVID-19. As on 1 October 2022, only 68% of the world population got the first dose of the vaccine. Although the vaccination is incredibly protective against severe complications of the disease and death, the highly contagious Omicron variant, compared to the Delta variant (B.1.617.2), has led the whole world into more chaotic situations. Furthermore, the virus has a high mutation rate, and hence, the possibility of a new variant of concern in the future cannot be ruled out. To face such a challenging situation, paramount importance should be given to rapid diagnosis and isolation of the infected patient. Current diagnosis methods, including reverse transcription-polymerase chain reaction and rapid antigen tests, face significant burdens during a COVID-19 wave. However, studies reported ultrarapid, reagent-free, cost-efficient, and non-destructive diagnosis methods based on chemometrics for COVID-19 and COVID-19 severity diagnosis. These studies used a smaller sample cohort to construct the diagnosis model and failed to discuss the robustness of the model. The current study systematically evaluated the robustness of the diagnosis models trained using smaller (real and augmented spectra) and larger (augmented spectra) datasets. The Monte Carlo cross-validation and permutation test results suggest that diagnosis using models trained by larger datasets was accurate and statistically significant (Q 2 > 99% and AUROC = 100%).
Collapse
Affiliation(s)
- Sreejith
Remanan Pushpa
- Material
Science and Technology Division, CSIR-National
Institute for Interdisciplinary Science and Technology, Industrial Estate P.O., Thiruvananthapuram695019, Kerala, India
- Academy
of Scientific and Innovative Research (AcSIR), Ghaziabad201002, India
| | - Rajeev Kumar Sukumaran
- Microbial
Processes and Technology Division, CSIR-National
Institute for Interdisciplinary Science and Technology, Industrial Estate P.O., Thiruvananthapuram695019, Kerala, India
- Academy
of Scientific and Innovative Research (AcSIR), Ghaziabad201002, India
| | - Sivaraman Savithri
- Material
Science and Technology Division, CSIR-National
Institute for Interdisciplinary Science and Technology, Industrial Estate P.O., Thiruvananthapuram695019, Kerala, India
- Academy
of Scientific and Innovative Research (AcSIR), Ghaziabad201002, India
| |
Collapse
|
27
|
Bannur Nanjunda S, Seshadri VN, Krishnan C, Rath S, Arunagiri S, Bao Q, Helmerson K, Zhang H, Jain R, Sundarrajan A, Srinivasan B. Emerging nanophotonic biosensor technologies for virus detection. NANOPHOTONICS (BERLIN, GERMANY) 2022; 11:5041-5059. [PMID: 39634299 PMCID: PMC11501160 DOI: 10.1515/nanoph-2022-0571] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/20/2022] [Revised: 11/09/2022] [Accepted: 11/13/2022] [Indexed: 12/07/2024]
Abstract
Highly infectious viral diseases are a serious threat to mankind as they can spread rapidly among the community, possibly even leading to the loss of many lives. Early diagnosis of a viral disease not only increases the chance of quick recovery, but also helps prevent the spread of infections. There is thus an urgent need for accurate, ultrasensitive, rapid, and affordable diagnostic techniques to test large volumes of the population to track and thereby control the spread of viral diseases, as evidenced during the COVID-19 and other viral pandemics. This review paper critically and comprehensively reviews various emerging nanophotonic biosensor mechanisms and biosensor technologies for virus detection, with a particular focus on detection of the SARS-CoV-2 (COVID-19) virus. The photonic biosensing mechanisms and technologies that we have focused on include: (a) plasmonic field enhancement via localized surface plasmon resonances, (b) surface enhanced Raman scattering, (c) nano-Fourier transform infrared (nano-FTIR) near-field spectroscopy, (d) fiber Bragg gratings, and (e) microresonators (whispering gallery modes), with a particular emphasis on the emerging impact of nanomaterials and two-dimensional materials in these photonic sensing technologies. This review also discusses several quantitative issues related to optical sensing with these biosensing and transduction techniques, notably quantitative factors that affect the limit of detection (LoD), sensitivity, specificity, and response times of the above optical biosensing diagnostic technologies for virus detection. We also review and analyze future prospects of cost-effective, lab-on-a-chip virus sensing solutions that promise ultrahigh sensitivities, rapid detection speeds, and mass manufacturability.
Collapse
Affiliation(s)
- Shivananju Bannur Nanjunda
- Department of Electrical Engineering, Centre of Excellence in Biochemical Sensing and Imaging (CenBioSIm), Indian Institute of Technology Madras, Chennai, India
| | - Venkatesh N. Seshadri
- Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India
- Department of Life Science, Indian Academy, Bangalore, India
| | - Chitra Krishnan
- School of Electronics Engineering, Vellore Institute of Technology, Chennai, India
| | - Sweta Rath
- Department of Electrical Engineering, Centre of Excellence in Biochemical Sensing and Imaging (CenBioSIm), Indian Institute of Technology Madras, Chennai, India
| | | | - Qiaoliang Bao
- Department of Materials Science and Engineering, and ARC Centre of Excellence in Future Low Energy Electronics Technologies (FLEET), Monash University, Clayton, VIC, Australia
| | - Kristian Helmerson
- School of Physics and Astronomy, ARC Centre of Excellence in Future Low-Energy Electronics Technologies (FLEET), Monash University, Clayton, VIC3800, Australia
| | - Han Zhang
- International Collaborative Laboratory of 2D Materials for Optoelectronics Science, College of Physics and Optoelectronic Engineering, Shenzhen University, Shenzhen518060, China
| | - Ravi Jain
- Optical Science and Engineering Program, Center for High Technology Materials, Departments of ECE, Physics Astronomy, and Nanoscience Microsystems, University of New Mexico, Albuquerque, NM87106, USA
| | - Asokan Sundarrajan
- Department of Instrumentation and Applied Physics, Indian Institute of Science, Bangalore, India
| | - Balaji Srinivasan
- Department of Electrical Engineering, Centre of Excellence in Biochemical Sensing and Imaging (CenBioSIm), Indian Institute of Technology Madras, Chennai, India
| |
Collapse
|
28
|
Preethi M, Roy L, Lahkar S, Borse V. Outlook of various diagnostics and nanodiagnostic techniques for COVID-19. BIOSENSORS & BIOELECTRONICS: X 2022; 12:100276. [PMID: 36345412 PMCID: PMC9632232 DOI: 10.1016/j.biosx.2022.100276] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 10/15/2022] [Accepted: 10/26/2022] [Indexed: 05/06/2023]
Abstract
The sudden outbreak of the coronavirus disease 2019 (COVID-19) pandemic has brought to the fore the existing threat of disease-causing pathogens that affect public health all over the world. It has left the best healthcare systems struggling to contain the spread of disease and its consequences. Under challenging circumstances, several innovative technologies have emerged that facilitated quicker diagnosis and treatment. Nanodiagnostic devices are biosensing platforms developed using nanomaterials such as nanoparticles, nanotubes, nanowires, etc. These devices have the edge over conventional techniques such as reverse transcription-polymerase chain reaction (RT-PCR) because of their ease of use, quicker analysis, possible miniaturization, and scope for use in point-of-care (POC) treatment. This review discusses the techniques currently used for COVID-19 diagnosis, emphasizing nanotechnology-based diagnostic devices. The commercialized nanodiagnostic devices in various research and development stages are also reviewed. The advantages of nanodiagnostic devices over other techniques are discussed, along with their limitations. Additionally, the important implications of the utility of nanodiagnostic devices in COVID-19, their prospects for future development for use in clinical and POC settings, and personalized healthcare are also discussed.
Collapse
Affiliation(s)
- Mosam Preethi
- NanoBioSens Lab, Department of Medical Devices, National Institute of Pharmaceutical Education & Research (NIPER) Hyderabad, Hyderabad, 500037, Telangana, India
| | - Lavanika Roy
- NanoBioSens Lab, Department of Medical Devices, National Institute of Pharmaceutical Education & Research (NIPER) Hyderabad, Hyderabad, 500037, Telangana, India
| | - Sukanya Lahkar
- NanoBioSens Lab, Department of Medical Devices, National Institute of Pharmaceutical Education & Research (NIPER) Hyderabad, Hyderabad, 500037, Telangana, India
| | - Vivek Borse
- NanoBioSens Lab, Department of Medical Devices, National Institute of Pharmaceutical Education & Research (NIPER) Hyderabad, Hyderabad, 500037, Telangana, India
| |
Collapse
|
29
|
Tian C, Zhao L, Qi G, Zhu J, Zhang S. One-pot and rapid detection of SARS-CoV-2 viral particles in environment using SERS aptasensor based on a locking amplifier. SENSORS AND ACTUATORS. B, CHEMICAL 2022; 371:132445. [PMID: 35919746 PMCID: PMC9335397 DOI: 10.1016/j.snb.2022.132445] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 07/26/2022] [Accepted: 07/28/2022] [Indexed: 05/07/2023]
Abstract
With the frequent detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) in dwellings and wastewater, the risk of transmission of environmental contaminants is of great concern. Fast, simple and sensitive sensors are essential for timely detecting infection and controlling transmission through environment fomites. Herein, we developed a Surface Enhanced Raman Scattering (SERS) aptasensor, which can realize ultrasensitive and rapid assay of SARS-CoV-2 viral particles. In this strategy, we designed a novel locking amplifier which is activated only in the presence of virus by aptamer recognition. The reaction process was carried out though one-pot method at 37 °C, which can save time and resources. In addition, magnetic beads used in reaction system can simplify operation, as well as provide ideas for developing biosensing robots via magnetic field. This SERS aptasensor can detect SARS-CoV-2 virus with a LOD of 260 TU/µL within 40 min in the linear range of 625-10,000 TU/µL. Therefore, this convenience, speediness, sensitivity, and selectivity of detection has great prospects in analyzing SARS-CoV-2 viral particles or other viruses in environment as well as monitoring of environmental virus sources.
Collapse
Affiliation(s)
- Cheng Tian
- Shandong Provincial Key Laboratory of Detection Technology for Tumor Markers, Collaborative Innovation Center of Tumor Marker Detection Technology, Equipment and Diagnosis-Therapy Integration in Universities of Shandong, College of Chemistry and Chemical Engineering, Linyi University, Linyi 276005, PR China
| | - Lei Zhao
- Shandong Provincial Key Laboratory of Detection Technology for Tumor Markers, Collaborative Innovation Center of Tumor Marker Detection Technology, Equipment and Diagnosis-Therapy Integration in Universities of Shandong, College of Chemistry and Chemical Engineering, Linyi University, Linyi 276005, PR China
| | - Guoliang Qi
- Shandong Provincial Key Laboratory of Detection Technology for Tumor Markers, Collaborative Innovation Center of Tumor Marker Detection Technology, Equipment and Diagnosis-Therapy Integration in Universities of Shandong, College of Chemistry and Chemical Engineering, Linyi University, Linyi 276005, PR China
| | - Jin Zhu
- Department of Polymer Science and Engineering, School of Chemistry and Chemical Engineering, State Key Laboratory of Coordination Chemistry, Nanjing National Laboratory of Microstructures, Collaborative Innovation Center of Chemistry for Life Sciences, Nanjing University, Nanjing 210023, PR China
| | - Shusheng Zhang
- Shandong Provincial Key Laboratory of Detection Technology for Tumor Markers, Collaborative Innovation Center of Tumor Marker Detection Technology, Equipment and Diagnosis-Therapy Integration in Universities of Shandong, College of Chemistry and Chemical Engineering, Linyi University, Linyi 276005, PR China
| |
Collapse
|
30
|
Alsalameh S, Alnajjar K, Makhzoum T, Al Eman N, Shakir I, Mir TA, Alkattan K, Chinnappan R, Yaqinuddin A. Advances in Biosensing Technologies for Diagnosis of COVID-19. BIOSENSORS 2022; 12:898. [PMID: 36291035 PMCID: PMC9599206 DOI: 10.3390/bios12100898] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Revised: 10/11/2022] [Accepted: 10/14/2022] [Indexed: 06/16/2023]
Abstract
The COVID-19 pandemic has severely impacted normal human life worldwide. Due to its rapid community spread and high mortality statistics, the development of prompt diagnostic tests for a massive number of samples is essential. Currently used traditional methods are often expensive, time-consuming, laboratory-based, and unable to handle a large number of specimens in resource-limited settings. Because of its high contagiousness, efficient identification of SARS-CoV-2 carriers is crucial. As the advantages of adopting biosensors for efficient diagnosis of COVID-19 increase, this narrative review summarizes the recent advances and the respective reasons to consider applying biosensors. Biosensors are the most sensitive, specific, rapid, user-friendly tools having the potential to deliver point-of-care diagnostics beyond traditional standards. This review provides a brief introduction to conventional methods used for COVID-19 diagnosis and summarizes their advantages and disadvantages. It also discusses the pathogenesis of COVID-19, potential diagnostic biomarkers, and rapid diagnosis using biosensor technology. The current advancements in biosensing technologies, from academic research to commercial achievements, have been emphasized in recent publications. We covered a wide range of topics, including biomarker detection, viral genomes, viral proteins, immune responses to infection, and other potential proinflammatory biomolecules. Major challenges and prospects for future application in point-of-care settings are also highlighted.
Collapse
Affiliation(s)
| | - Khalid Alnajjar
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
| | - Tariq Makhzoum
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
| | - Noor Al Eman
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
| | - Ismail Shakir
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
| | - Tanveer Ahmad Mir
- Laboratory of Tissue/Organ Bioengineering and BioMEMS, Organ Transplant Centre of Excellence, Transplant Research and Innovation Department, King Faisal Specialist Hospital and Research Centre, Riyadh 11211, Saudi Arabia
| | - Khaled Alkattan
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
| | - Raja Chinnappan
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
| | - Ahmed Yaqinuddin
- College of Medicine, Alfaisal University, Riyadh 11533, Saudi Arabia
| |
Collapse
|
31
|
Park S, Su Jeon C, Choi N, Moon JI, Min Lee K, Hyun Pyun S, Kang T, Choo J. Sensitive and reproducible detection of SARS-CoV-2 using SERS-based microdroplet sensor. CHEMICAL ENGINEERING JOURNAL (LAUSANNE, SWITZERLAND : 1996) 2022; 446:137085. [PMID: 35611066 PMCID: PMC9121656 DOI: 10.1016/j.cej.2022.137085] [Citation(s) in RCA: 25] [Impact Index Per Article: 8.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/01/2022] [Revised: 05/13/2022] [Accepted: 05/17/2022] [Indexed: 05/08/2023]
Abstract
Surface-enhanced Raman scattering (SERS)-based assays have been recently developed to overcome the low detection sensitivity of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). SERS-based assays using magnetic beads in microtubes slightly improved the limit of detection (LoD) for SARS-CoV-2. However, the sensitivity and reproducibility of the method are still insufficient for reliable SARS-CoV-2 detection. In this study, we developed a SERS-based microdroplet sensor to dramatically improve the LoD and reproducibility of SARS-CoV-2 detection. Raman signals were measured for SERS nanotags in 140 droplets passing through a laser focal volume fixed at the center of the channel for 15 s. A comparison of the Raman signals of SERS nanotags measured in a microtube with those measured for multiple droplets in the microfluidic channel revealed that the LoD and coefficient of variation significantly improved from 36 to 0.22 PFU/mL and 21.2% to 1.79%, respectively. This improvement resulted from the ensemble average effects because the signals were measured for SERS nanotags in multiple droplets. Moreover, the total assay time decreased from 30 to 10 min. A clinical test was performed on patient samples to evaluate the clinical efficacy of the SERS-based microdroplet sensor. The assay results agreed well with those measured by the reverse transcription-polymerase chain reaction (RT-PCR) method. The proposed SERS-based microdroplet sensor is expected to be used as a new point-of-care diagnostic platform for quick and accurate detection of SARS-CoV-2 in the field.
Collapse
Affiliation(s)
- Sohyun Park
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea
| | - Chang Su Jeon
- R&D Center, Speclipse Inc., Seongnam 13461, South Korea
| | - Namhyun Choi
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea
| | - Joung-Il Moon
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea
| | - Kang Min Lee
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea
| | | | - Taejoon Kang
- Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology (KRIBB), Daejeon 34141, South Korea
| | - Jaebum Choo
- Department of Chemistry, Chung-Ang University, Seoul 06974, South Korea
| |
Collapse
|
32
|
Shahdeo D, Roberts A, Archana GJ, Shrikrishna NS, Mahari S, Nagamani K, Gandhi S. Label free detection of SARS CoV-2 Receptor Binding Domain (RBD) protein by fabrication of gold nanorods deposited on electrochemical immunosensor (GDEI). Biosens Bioelectron 2022; 212:114406. [PMID: 35635976 PMCID: PMC9121652 DOI: 10.1016/j.bios.2022.114406] [Citation(s) in RCA: 38] [Impact Index Per Article: 12.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/15/2022] [Accepted: 05/17/2022] [Indexed: 12/18/2022]
Abstract
Coronavirus Disease 2019 (COVID-19) pandemic has shown the need for early diagnosis to manage infectious disease outbreaks. Here, we report a label free electrochemical Fluorine-Doped Tin Oxide (FTO) Immunosensor coupled with gold nanorods (GNRs) as an electron carrier for ultrasensitive detection of the Receptor Binding Domain (RBD) of SARS CoV-2 Spike protein. The RBD gene was cloned, and expressed in-house with confirmed molecular weight of ∼31 kDa via Sodium Dodecyl Sulphate-Polyacrylamide Gel Electrophoresis (SDS-PAGE) and Matrix-Assisted Laser Desorption/Ionization-Time of Flight (MALDI-TOF). RBD antibodies (Ab) were generated to be used as a bioreceptor for sensor fabrication, and characterized using SDS-PAGE, Western Blot, and Enzyme-Linked Immunosorbent Assay (ELISA). GNRs were fabricated on the electrode surface, followed by immobilization of RBD Ab. The conjugation steps were confirmed by UV-Vis Spectroscopy, Dynamic Light Scattering (DLS), Atomic Force Microscopy (AFM), Transmission Electron Microscopy (TEM), Cyclic Voltammetry (CV), and Differential Pulse Voltammetry (DPV). The fabricated electrode was further optimized for maximum efficiency and output. The detection limit of the developed electrode was determined as 0.73 fM for RBD antigen (Ag). Furthermore, the patient nasopharyngeal samples were collected in Viral Transport Media (VTM), and tested on the sensor surface that resulted in detection of SARS CoV-2 within 30 s, which was further validated via Reverse Transcription-Polymerase Chain Reaction (RT-PCR). Moreover, the immunosensor showed good repeatability, storage stability, and minimal cross reactivity against Middle East Respiratory Syndrome (MERS) spike protein. Along with ease of fabrication, the electrodes show future miniaturization potential for extensive and rapid screening of populations for COVID-19.
Collapse
Affiliation(s)
- Deepshikha Shahdeo
- DBT- National Institute of Animal Biotechnology (NIAB), Hyderabad, 500032, Telangana, India
| | - Akanksha Roberts
- DBT- National Institute of Animal Biotechnology (NIAB), Hyderabad, 500032, Telangana, India
| | - G J Archana
- Department of Microbiology, Gandhi Medical College, Gandhi Hospital, Hyderabad, 500025, Telangana, India
| | | | - Subhasis Mahari
- DBT- National Institute of Animal Biotechnology (NIAB), Hyderabad, 500032, Telangana, India
| | - K Nagamani
- Department of Microbiology, Gandhi Medical College, Gandhi Hospital, Hyderabad, 500025, Telangana, India
| | - Sonu Gandhi
- DBT- National Institute of Animal Biotechnology (NIAB), Hyderabad, 500032, Telangana, India.
| |
Collapse
|
33
|
Castrejón-Jiménez NS, García-Pérez BE, Reyes-Rodríguez NE, Vega-Sánchez V, Martínez-Juárez VM, Hernández-González JC. Challenges in the Detection of SARS-CoV-2: Evolution of the Lateral Flow Immunoassay as a Valuable Tool for Viral Diagnosis. BIOSENSORS 2022; 12:bios12090728. [PMID: 36140114 PMCID: PMC9496238 DOI: 10.3390/bios12090728] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/30/2022] [Revised: 09/02/2022] [Accepted: 09/02/2022] [Indexed: 12/11/2022]
Abstract
SARS-CoV-2 is an emerging infectious disease of zoonotic origin that caused the coronavirus disease in late 2019 and triggered a pandemic that has severely affected human health and caused millions of deaths. Early and massive diagnosis of SARS-CoV-2 infected patients is the key to preventing the spread of the virus and controlling the outbreak. Lateral flow immunoassays (LFIA) are the simplest biosensors. These devices are clinical diagnostic tools that can detect various analytes, including viruses and antibodies, with high sensitivity and specificity. This review summarizes the advantages, limitations, and evolution of LFIA during the SARS-CoV-2 pandemic and the challenges of improving these diagnostic devices.
Collapse
Affiliation(s)
- Nayeli Shantal Castrejón-Jiménez
- Área Académica de Medicina Veterinaria y Zootecnia, Instituto de Ciencias Agropecuarias, Universidad Autónoma del Estado de Hidalgo, Av. Universidad km 1 Exhacienda de Aquetzalpa A.P. 32, Tulancingo 43600, Mexico
| | - Blanca Estela García-Pérez
- Department of Microbiology, Instituto Politécnico Nacional, Escuela Nacional de Ciencias Biológicas Prolongación de Carpio y Plan de Ayala S/N, Col. Santo Tomás, México City 11340, Mexico
| | - Nydia Edith Reyes-Rodríguez
- Área Académica de Medicina Veterinaria y Zootecnia, Instituto de Ciencias Agropecuarias, Universidad Autónoma del Estado de Hidalgo, Av. Universidad km 1 Exhacienda de Aquetzalpa A.P. 32, Tulancingo 43600, Mexico
| | - Vicente Vega-Sánchez
- Área Académica de Medicina Veterinaria y Zootecnia, Instituto de Ciencias Agropecuarias, Universidad Autónoma del Estado de Hidalgo, Av. Universidad km 1 Exhacienda de Aquetzalpa A.P. 32, Tulancingo 43600, Mexico
| | - Víctor Manuel Martínez-Juárez
- Área Académica de Medicina Veterinaria y Zootecnia, Instituto de Ciencias Agropecuarias, Universidad Autónoma del Estado de Hidalgo, Av. Universidad km 1 Exhacienda de Aquetzalpa A.P. 32, Tulancingo 43600, Mexico
| | - Juan Carlos Hernández-González
- Área Académica de Medicina Veterinaria y Zootecnia, Instituto de Ciencias Agropecuarias, Universidad Autónoma del Estado de Hidalgo, Av. Universidad km 1 Exhacienda de Aquetzalpa A.P. 32, Tulancingo 43600, Mexico
- Correspondence: ; Tel.: +52-775-756-0308
| |
Collapse
|
34
|
Xu M, Lin L, Jin G, Lin Y, Zhang K. Two-in-one: Portable piezoelectric and plasmonic exciton effect-based co-enhanced photoelectrochemical biosensor for point-of-care testing of low-abundance cancer markers. Biosens Bioelectron 2022; 211:114413. [DOI: 10.1016/j.bios.2022.114413] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2022] [Revised: 05/01/2022] [Accepted: 05/18/2022] [Indexed: 11/02/2022]
|
35
|
Naikoo GA, Arshad F, Hassan IU, Awan T, Salim H, Pedram MZ, Ahmed W, Patel V, Karakoti AS, Vinu A. Nanomaterials-based sensors for the detection of COVID-19: A review. Bioeng Transl Med 2022; 7:e10305. [PMID: 35599642 PMCID: PMC9110902 DOI: 10.1002/btm2.10305] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2021] [Revised: 02/07/2022] [Accepted: 02/08/2022] [Indexed: 12/13/2022] Open
Abstract
With the threat of increasing SARS-CoV-2 cases looming in front of us and no effective and safest vaccine available to curb this pandemic disease due to its sprouting variants, many countries have undergone a lockdown 2.0 or planning a lockdown 3.0. This has upstretched an unprecedented demand to develop rapid, sensitive, and highly selective diagnostic devices that can quickly detect coronavirus (COVID-19). Traditional techniques like polymerase chain reaction have proven to be time-inefficient, expensive, labor intensive, and impracticable in remote settings. This shifts the attention to alternative biosensing devices that can be successfully used to sense the COVID-19 infection and curb the spread of coronavirus cases. Among these, nanomaterial-based biosensors hold immense potential for rapid coronavirus detection because of their noninvasive and susceptible, as well as selective properties that have the potential to give real-time results at an economical cost. These diagnostic devices can be used for mass COVID-19 detection to understand the rapid progression of the infection and give better-suited therapies. This review provides an overview of existing and potential nanomaterial-based biosensors that can be used for rapid SARS-CoV-2 diagnostics. Novel biosensors employing different detection mechanisms are also highlighted in different sections of this review. Practical tools and techniques required to develop such biosensors to make them reliable and portable have also been discussed in the article. Finally, the review is concluded by presenting the current challenges and future perspectives of nanomaterial-based biosensors in SARS-CoV-2 diagnostics.
Collapse
Affiliation(s)
- Gowhar A. Naikoo
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahSultanate of Oman
| | - Fareeha Arshad
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahSultanate of Oman
| | - Israr U. Hassan
- College of Engineering, Dhofar UniversitySalalahSultanate of Oman
| | - Tasbiha Awan
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahSultanate of Oman
| | - Hiba Salim
- Department of Mathematics and SciencesCollege of Arts and Applied Sciences, Dhofar UniversitySalalahSultanate of Oman
| | - Mona Z. Pedram
- Faculty of Mechanical Engineering‐Energy DivisionK.N. Toosi University of TechnologyTehranIran
| | - Waqar Ahmed
- School of Mathematics and Physics, College of ScienceUniversity of LincolnLincolnUK
| | - Vaishwik Patel
- Global Innovative Center for Advanced NanomaterialsCollege of Engineering, Science and Environment, The University of NewcastleCallaghanAustralia
| | - Ajay S. Karakoti
- Global Innovative Center for Advanced NanomaterialsCollege of Engineering, Science and Environment, The University of NewcastleCallaghanAustralia
| | - Ajayan Vinu
- Global Innovative Center for Advanced NanomaterialsCollege of Engineering, Science and Environment, The University of NewcastleCallaghanAustralia
| |
Collapse
|
36
|
Shim JE, Kim YJ, Choe JH, Lee TG, You EA. Single-Nanoparticle-Based Digital SERS Sensing Platform for the Accurate Quantitative Detection of SARS-CoV-2. ACS APPLIED MATERIALS & INTERFACES 2022; 14:38459-38470. [PMID: 35951983 PMCID: PMC9396967 DOI: 10.1021/acsami.2c07497] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 08/01/2022] [Indexed: 06/15/2023]
Abstract
To prevent the ongoing spread of the highly infectious severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), accurate and early detection based on a rapid, ultrasensitive, and highly reliable sensing method is crucially important. Here, we present a bumpy core-shell surface-enhanced Raman spectroscopy (SERS) nanoprobe-based sensing platform with single-nanoparticle (SNP)-based digital SERS analysis. The tailorable bumpy core-shell SERS nanoprobe with an internal self-assembled monolayer of 4-nitrobenzenethiol Raman reporters, synthesized using HEPES biological buffer, generates a strong, uniform, and reproducible SERS signal with an SNP-level sensitive and narrowly distributed enhancement factor (2.1 × 108 to 2.2 × 109). We also propose an SNP-based digital SERS analysis method that provides direct visualization of SNP detection at ultralow concentrations and reliable quantification over a wide range of concentrations. The bumpy core-shell SERS nanoprobe-based sensing platform with SNP-based digital SERS analysis achieves the ultrasensitive and quantitative detection of the SARS-CoV-2 spike protein with a limit of detection of 7.1 × 10-16 M over a wide dynamic range from 3.7 × 10-15 to 3.7 × 10-8 M, far outperforming the conventional enzyme-linked immunosorbent assay method for the target protein. Furthermore, it can detect mutated spike proteins from the SARS-CoV-2 variants, representing the key mutations of Alpha, Beta, Gamma, Delta, and Omicron variants. Therefore, this sensing platform can be effectively and efficiently used for the accurate and early detection of SARS-CoV-2 and be adapted for the ultrasensitive and reliable detection of other highly infectious diseases.
Collapse
Affiliation(s)
- Jae-Eul Shim
- Nanobiosensor
Team, Korea Research Institute of Standards
and Science, Daejeon 34113, Republic of Korea
| | - Young Jun Kim
- Nanobiosensor
Team, Korea Research Institute of Standards
and Science, Daejeon 34113, Republic of Korea
| | - Jong-Ho Choe
- Department
of Physics, Korea University, Seoul 02841, Republic of Korea
| | - Tae Geol Lee
- Nanobiosensor
Team, Korea Research Institute of Standards
and Science, Daejeon 34113, Republic of Korea
| | - Eun-Ah You
- Nanobiosensor
Team, Korea Research Institute of Standards
and Science, Daejeon 34113, Republic of Korea
| |
Collapse
|
37
|
Białobrzeska W, Ficek M, Dec B, Osella S, Trzaskowski B, Jaramillo-Botero A, Pierpaoli M, Rycewicz M, Dashkevich Y, Łęga T, Malinowska N, Cebula Z, Bigus D, Firganek D, Bięga E, Dziąbowska K, Brodowski M, Kowalski M, Panasiuk M, Gromadzka B, Żołędowska S, Nidzworski D, Pyrć K, Goddard WA, Bogdanowicz R. Performance of electrochemical immunoassays for clinical diagnostics of SARS-CoV-2 based on selective nucleocapsid N protein detection: Boron-doped diamond, gold and glassy carbon evaluation. Biosens Bioelectron 2022; 209:114222. [PMID: 35430407 PMCID: PMC8989705 DOI: 10.1016/j.bios.2022.114222] [Citation(s) in RCA: 26] [Impact Index Per Article: 8.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2021] [Revised: 03/17/2022] [Accepted: 03/24/2022] [Indexed: 01/09/2023]
Abstract
The 21st century has already brought us a plethora of new threats related to viruses that emerge in humans after zoonotic transmission or drastically change their geographic distribution or prevalence. Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) was first spotted at the end of 2019 to rapidly spread in southwest Asia and later cause a global pandemic, which paralyzes the world since then. We have designed novel immunosensors targeting conserved protein sequences of the N protein of SARS-CoV-2 based on lab-produced and purified anti-SARS-CoV-2 nucleocapsid antibodies that are densely grafted onto various surfaces (diamond/gold/glassy carbon). Titration of antibodies shows very strong reactions up to 1:72 900 dilution. Next, we showed the mechanism of interactions of our immunoassay with nucleocapsid N protein revealing molecular recognition by impedimetric measurements supported by hybrid modeling results with both density functional theory and molecular dynamics methods. Biosensors allowed for a fast (in less than 10 min) detection of SARS-CoV-2 virus with a limit of detection from 0.227 ng/ml through 0.334 ng/ml to 0.362 ng/ml for glassy carbon, boron-doped diamond, and gold surfaces, respectively. For all tested surfaces, we obtained a wide linear range of concentrations from 4.4 ng/ml to 4.4 pg/ml. Furthermore, our sensor leads to a highly specific response to SARS-CoV-2 clinical samples versus other upper respiratory tract viruses such as influenza, respiratory syncytial virus, or Epstein-Barr virus. All clinical samples were tested simultaneously on biosensors and real-time polymerase chain reactions.
Collapse
|
38
|
Wei H, Zhang C, Du X, Zhang Z. Research progress of biosensors for detection of SARS-CoV-2 variants based on ACE2. Talanta 2022; 251:123813. [PMID: 35952504 PMCID: PMC9356646 DOI: 10.1016/j.talanta.2022.123813] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 07/30/2022] [Accepted: 08/02/2022] [Indexed: 11/12/2022]
Abstract
Currently, the coronavirus disease 2019 (COVID-19) pandemic is ravaging the world, causing serious crisis in economy and human health. The top priority is the detection and drug development of the novel coronavirus. The gold standard for real-time diagnosis of coronavirus disease is the reverse transcription-polymerase chain reaction (RT-PCR), which is usually operatively complex and time-consuming. Biosensors are known for their low cost and rapid detection, which are developing rapidly in detecting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). The current study showed that the spike protein of SARS-CoV-2 will bind to angiotensin-converting hormone 2 (ACE2) to mediate the entry of the virus into cells. Interestingly, the affinity between ACE2 and SARS-CoV-2 spike protein increases with the mutation of the virus. Using ACE2 as a biosensor recognition receptor to detect SARS-CoV-2 will effectively avoid the decline of detection accuracy and false negative caused by variants. In fact, due to the variation of the virus, it may even lead to enhanced detection performance. In addition, ACE2-specific drugs to prevent SARS-CoV-2 from entering cells will be effectively evaluated using the biosensors even with virus mutations. Here, we reviewed the biosensors for rapid detection of SARS-CoV-2 by ACE2 and discussed the advantages of ACE2 as an antibody for the detection of SARS-CoV-2 variants. The review also discussed the value of ACE2-based biosensors for screening for drugs that modulate the interaction between ACE2 and SARS-CoV-2.
Collapse
|
39
|
Ayala-Charca G, Salahandish R, Khalghollah M, Sadighbayan D, Haghayegh F, Sanati-Nezhad A, Ghafar-Zadeh E. A Low-Cost Handheld Impedimetric Biosensing System for Rapid Diagnostics of SARS-CoV-2 Infections. IEEE SENSORS JOURNAL 2022; 22:15673-15682. [PMID: 36346096 PMCID: PMC9454264 DOI: 10.1109/jsen.2022.3181580] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/03/2022] [Accepted: 05/25/2022] [Indexed: 06/12/2023]
Abstract
Current laboratory diagnostic approaches for virus detection give reliable results, but they require a lengthy procedure, trained personnel, and expensive equipment and reagents; hence, they are not a suitable choice for home monitoring purposes. This paper addresses this challenge by developing a portable impedimetric biosensing system for the identification of COVID-19 patients. This sensing system has two main parts: a throwaway two-working electrode (2-WE) strip and a novel read-out circuit, specifically designed for simultaneous signal acquisition from both working electrodes. Highly reliable electrochemical signal tracking from multiplex immunosensors provides a potential for flexible and portable multi-biomarker detection. The electrodes' surfaces were functionalized with SARS-CoV-2 Nucleocapsid Antibody enabling the selective detection of Nucleocapsid protein (N-protein) along with self-validation in the clinical nasopharyngeal swab specimens. The proposed programmable highly sensitive impedance read-out system allows for a wide dynamic detection range, which makes the sensor capable of detecting N-protein concentrations between 0.116 and 10,000 pg/mL. This lightweight and economical read-out arrangement is an ideal prospect for being mass-produced, especially during urgent pandemic situations. Also, such an impedimetric sensing platform has the potential to be redesigned for targeting not only other infectious diseases but also other critical disorders.
Collapse
Affiliation(s)
- Giancarlo Ayala-Charca
- Biologically Inspired Sensors and ActuatorsDepartment of Electrical Engineering and Computer Science, Lassonde School of EngineeringYork UniversityTorontoONM3J1P3Canada
| | - Razieh Salahandish
- BioMEMS and Bioinspired Microfluidic LaboratoryDepartment of Mechanical and Manufacturing EngineeringUniversity of CalgaryCalgaryABT2N 1N4Canada
- Center for Bioengineering Research and EducationUniversity of CalgaryCalgaryABT2N 1N4Canada
| | - Mahmood Khalghollah
- BioMEMS and Bioinspired Microfluidic LaboratoryDepartment of Mechanical and Manufacturing EngineeringUniversity of CalgaryCalgaryABT2N 1N4Canada
- Department of Electrical and Software EngineeringUniversity of CalgaryCalgaryABT2N 1N4Canada
| | - Deniz Sadighbayan
- Biologically Inspired Sensors and ActuatorsDepartment of Electrical Engineering and Computer Science, Lassonde School of EngineeringYork UniversityTorontoONM3J1P3Canada
| | - Fatemeh Haghayegh
- BioMEMS and Bioinspired Microfluidic LaboratoryDepartment of Mechanical and Manufacturing EngineeringUniversity of CalgaryCalgaryABT2N 1N4Canada
| | - Amir Sanati-Nezhad
- BioMEMS and Bioinspired Microfluidic LaboratoryDepartment of Mechanical and Manufacturing EngineeringUniversity of CalgaryCalgaryABT2N 1N4Canada
- Center for Bioengineering Research and EducationUniversity of CalgaryCalgaryABT2N 1N4Canada
- Biomedical Engineering Graduate ProgramUniversity of CalgaryCalgaryABT2N 1N4Canada
| | - Ebrahim Ghafar-Zadeh
- Biologically Inspired Sensors and ActuatorsDepartment of Electrical Engineering and Computer Science, Lassonde School of EngineeringYork UniversityTorontoONM3J1P3Canada
| |
Collapse
|
40
|
Liu Q, Chen S, Wang L, Duan Z, Xie F, Zhao G, Hou Y, Luo D. MOPCS: next-generation nucleic acid molecular bio-sensor. Natl Sci Rev 2022; 9:nwac149. [PMID: 36128455 PMCID: PMC9477196 DOI: 10.1093/nsr/nwac149] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2022] [Accepted: 07/27/2022] [Indexed: 11/23/2022] Open
Affiliation(s)
- Quan Liu
- Laboratory Medicine Center, Huazhong University of Science and Technology Union Shenzhen Hospital (Nanshan Hospital) , Shenzhen 518000 , China
| | - Shang Chen
- Laboratory Medicine Center, Huazhong University of Science and Technology Union Shenzhen Hospital (Nanshan Hospital) , Shenzhen 518000 , China
| | - Li Wang
- Laboratory Medicine Center, Huazhong University of Science and Technology Union Shenzhen Hospital (Nanshan Hospital) , Shenzhen 518000 , China
| | - Zhaojun Duan
- National Institute For Viral Disease Control and Prevention, China Center for Disease Control and Prevention , Beijing 102206 , China
| | - Fuquan Xie
- Department of Laboratory Medicine, Shenzhen Children's Hospital , Shenzhen 518038 , China
| | - Guojun Zhao
- The Sixth Affiliated Hospital of Guangzhou Medical University, Qingyuan City People's Hospital , Qingyuan 511518 , China
| | - Yunde Hou
- National Institute For Viral Disease Control and Prevention, China Center for Disease Control and Prevention , Beijing 102206 , China
| | - Dixian Luo
- Laboratory Medicine Center, Huazhong University of Science and Technology Union Shenzhen Hospital (Nanshan Hospital) , Shenzhen 518000 , China
| |
Collapse
|
41
|
Fortunati S, Giannetto M, Giliberti C, Bolchi A, Ferrari D, Locatelli M, Bianchi V, Boni A, De Munari I, Careri M. Smart Immunosensors for Point-of-Care Serological Tests Aimed at Assessing Natural or Vaccine-Induced SARS-CoV-2 Immunity. SENSORS (BASEL, SWITZERLAND) 2022; 22:5463. [PMID: 35891142 PMCID: PMC9325165 DOI: 10.3390/s22145463] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/16/2022] [Revised: 07/15/2022] [Accepted: 07/19/2022] [Indexed: 06/15/2023]
Abstract
Innovative and highly performing smart voltammetric immunosensors for rapid and effective serological tests aimed at the determination of SARS-CoV-2 antibodies were developed and validated in human serum matrix. Two immunosensors were developed for the determination of immunoglobulins directed against either the nucleocapsid or the spike viral antigen proteins. The immunosensors were realized using disposable screen-printed electrodes modified with nanostructured materials for the immobilization of the antigens. Fast quantitative detection was achieved, with analysis duration being around 1 h. Signal readout was carried out through a smart, compact and battery-powered potentiostat, based on a Wi-Fi protocol and devised for the Internet of Things (IoT) paradigm. This device is used for the acquisition, storage and sharing of clinical data. Outstanding immunosensors' sensitivity, specificity and accuracy (100%) were assessed, according to the diagnostic guidelines for epidemiological data. The overall performance of the sensing devices, combined with the portability of the IoT-based device, enables their suitability as a high-throughput diagnostic tool. Both of the immunosensors were validated using clinical human serum specimens from SARS-CoV-2 infected patients, provided by IRCCS Ospedale San Raffaele.
Collapse
Affiliation(s)
- Simone Fortunati
- Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Università di Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy; (S.F.); (C.G.); (A.B.); (D.F.)
| | - Marco Giannetto
- Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Università di Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy; (S.F.); (C.G.); (A.B.); (D.F.)
| | - Chiara Giliberti
- Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Università di Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy; (S.F.); (C.G.); (A.B.); (D.F.)
| | - Angelo Bolchi
- Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Università di Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy; (S.F.); (C.G.); (A.B.); (D.F.)
| | - Davide Ferrari
- Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Università di Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy; (S.F.); (C.G.); (A.B.); (D.F.)
| | | | - Valentina Bianchi
- Dipartimento di Ingegneria e Architettura, Università di Parma, Parco Area delle Scienze 181/A, 43124 Parma, Italy; (V.B.); (A.B.); (I.D.M.)
| | - Andrea Boni
- Dipartimento di Ingegneria e Architettura, Università di Parma, Parco Area delle Scienze 181/A, 43124 Parma, Italy; (V.B.); (A.B.); (I.D.M.)
| | - Ilaria De Munari
- Dipartimento di Ingegneria e Architettura, Università di Parma, Parco Area delle Scienze 181/A, 43124 Parma, Italy; (V.B.); (A.B.); (I.D.M.)
| | - Maria Careri
- Dipartimento di Scienze Chimiche, della Vita e della Sostenibilità Ambientale, Università di Parma, Parco Area delle Scienze 17/A, 43124 Parma, Italy; (S.F.); (C.G.); (A.B.); (D.F.)
| |
Collapse
|
42
|
Abstract
Rapid and early diagnosis of lethal coronavirus disease-19 (COVID-19) caused by the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is an important issue considering global human health, economy, education, and other activities. The advancement of understanding of the chemistry/biochemistry and the structure of the SARS-CoV-2 virus has led to the development of low-cost, efficient, and reliable methods for COVID-19 diagnosis over “gold standard” real-time reverse transcription-polymerase chain reaction (RT-PCR) due to its several limitations. This led to the development of electrochemical sensors/biosensors for rapid, fast, and low-cost detection of the SARS-CoV-2 virus from the patient’s biological fluids by detecting the components of the virus, including structural proteins (antigens), nucleic acid, and antibodies created after COVID-19 infection. This review comprehensively summarizes the state-of-the-art research progress of electrochemical biosensors for COVID-19 diagnosis. They include the detection of spike protein, nucleocapsid protein, whole virus, nucleic acid, and antibodies. The review also outlines the structure of the SARS-CoV-2 virus, different detection methods, and design strategies of electrochemical SARS-CoV-2 biosensors by highlighting the current challenges and future perspectives.
Collapse
|
43
|
Mei Y, Lin X, He C, Zeng W, Luo Y, Liu C, Liu Z, Yang M, Kuang Y, Huang Q. Recent Progresses in Electrochemical DNA Biosensors for SARS-CoV-2 Detection. Front Bioeng Biotechnol 2022; 10:952510. [PMID: 35910031 PMCID: PMC9335408 DOI: 10.3389/fbioe.2022.952510] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Accepted: 06/10/2022] [Indexed: 12/16/2022] Open
Abstract
Coronavirus disease 19 (COVID-19) is still a major public health concern in many nations today. COVID-19 transmission is now controlled mostly through early discovery, isolation, and therapy. Because of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is the contributing factor to COVID-19, establishing timely, sensitive, accurate, simple, and budget detection technologies for the SARS-CoV-2 is urgent for epidemic prevention. Recently, several electrochemical DNA biosensors have been developed for the rapid monitoring and detection of SARS-CoV-2. This mini-review examines the latest improvements in the detection of SARS-COV-2 utilizing electrochemical DNA biosensors. Meanwhile, this mini-review summarizes the problems faced by the existing assays and puts an outlook on future trends in the development of new assays for SARS-CoV-2, to provide researchers with a borrowing role in the generation of different assays.
Collapse
Affiliation(s)
- Yanqiu Mei
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases, Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Public Health and Health Management, School of Medical and Information Engineering, Gannan Medical University, Ganzhou, China
| | - Xiaofeng Lin
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases, Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Public Health and Health Management, School of Medical and Information Engineering, Gannan Medical University, Ganzhou, China
- Oil-Tea in Medical Health Care and Functional Product Development Engineering Research Center in Jiangxi, The Science Research Center, School of Pharmacy, Gannan Medical University, Ganzhou, China
| | - Chen He
- Oil-Tea in Medical Health Care and Functional Product Development Engineering Research Center in Jiangxi, The Science Research Center, School of Pharmacy, Gannan Medical University, Ganzhou, China
| | - Weijia Zeng
- Oil-Tea in Medical Health Care and Functional Product Development Engineering Research Center in Jiangxi, The Science Research Center, School of Pharmacy, Gannan Medical University, Ganzhou, China
| | - Yan Luo
- Oil-Tea in Medical Health Care and Functional Product Development Engineering Research Center in Jiangxi, The Science Research Center, School of Pharmacy, Gannan Medical University, Ganzhou, China
| | - Chenghao Liu
- Oil-Tea in Medical Health Care and Functional Product Development Engineering Research Center in Jiangxi, The Science Research Center, School of Pharmacy, Gannan Medical University, Ganzhou, China
| | - Zhehao Liu
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases, Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Public Health and Health Management, School of Medical and Information Engineering, Gannan Medical University, Ganzhou, China
- Oil-Tea in Medical Health Care and Functional Product Development Engineering Research Center in Jiangxi, The Science Research Center, School of Pharmacy, Gannan Medical University, Ganzhou, China
| | - Min Yang
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases, Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Public Health and Health Management, School of Medical and Information Engineering, Gannan Medical University, Ganzhou, China
- Oil-Tea in Medical Health Care and Functional Product Development Engineering Research Center in Jiangxi, The Science Research Center, School of Pharmacy, Gannan Medical University, Ganzhou, China
| | - Ying Kuang
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases, Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Public Health and Health Management, School of Medical and Information Engineering, Gannan Medical University, Ganzhou, China
- Oil-Tea in Medical Health Care and Functional Product Development Engineering Research Center in Jiangxi, The Science Research Center, School of Pharmacy, Gannan Medical University, Ganzhou, China
| | - Qitong Huang
- Key Laboratory of Prevention and Treatment of Cardiovascular and Cerebrovascular Diseases, Ministry of Education, Key Laboratory of Biomaterials and Biofabrication in Tissue Engineering of Jiangxi Province, Key Laboratory of Biomedical Sensors of Ganzhou, School of Public Health and Health Management, School of Medical and Information Engineering, Gannan Medical University, Ganzhou, China
- Oil-Tea in Medical Health Care and Functional Product Development Engineering Research Center in Jiangxi, The Science Research Center, School of Pharmacy, Gannan Medical University, Ganzhou, China
| |
Collapse
|
44
|
Xu L, Ramadan S, Rosa BG, Zhang Y, Yin T, Torres E, Shaforost O, Panagiotopoulos A, Li B, Kerherve G, Kim DK, Mattevi C, Jiao LR, Petrov PK, Klein N. On-chip integrated graphene aptasensor with portable readout for fast and label-free COVID-19 detection in virus transport medium. SENSORS & DIAGNOSTICS 2022; 1:719-730. [PMID: 35923775 PMCID: PMC9280445 DOI: 10.1039/d2sd00076h] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 06/10/2022] [Indexed: 01/12/2023]
Abstract
Graphene field-effect transistor (GFET) biosensors exhibit high sensitivity due to a large surface-to-volume ratio and the high sensitivity of the Fermi level to the presence of charged biomolecules near the surface. For most reported GFET biosensors, bulky external reference electrodes are used which prevent their full-scale chip integration and contribute to higher costs per test. In this study, GFET arrays with on-chip integrated liquid electrodes were employed for COVID-19 detection and functionalized with either antibody or aptamer to selectively bind the spike proteins of SARS-CoV-2. In the case of the aptamer-functionalized GFET (aptasensor, Apt-GFET), the limit-of-detection (LOD) achieved was about 103 particles per mL for virus-like particles (VLPs) in clinical transport medium, outperforming the Ab-GFET biosensor counterpart. In addition, the aptasensor achieved a LOD of 160 aM for COVID-19 neutralizing antibodies in serum. The sensors were found to be highly selective, fast (sample-to-result within minutes), and stable (low device-to-device signal variation; relative standard deviations below 0.5%). A home-built portable readout electronic unit was employed for simultaneous real-time measurements of 12 GFETs per chip. Our successful demonstration of a portable GFET biosensing platform has high potential for infectious disease detection and other health-care applications.
Collapse
Affiliation(s)
- Lizhou Xu
- Department of Materials, Imperial College LondonLondonSW7 2AZUK,ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang UniversityHangzhou311200China
| | - Sami Ramadan
- Department of Materials, Imperial College LondonLondonSW7 2AZUK
| | | | - Yuanzhou Zhang
- Department of Materials, Imperial College LondonLondonSW7 2AZUK
| | - Tianyi Yin
- Department of Materials, Imperial College LondonLondonSW7 2AZUK
| | - Elias Torres
- Graphenea SemiconductorPaseo Mikeletegi 83San Sebastián20009Spain
| | - Olena Shaforost
- Department of Materials, Imperial College LondonLondonSW7 2AZUK
| | | | - Bing Li
- Department of Brain Sciences, Imperial College LondonLondonW12 0BZUK,Care Research & Technology Centre, UK Dementia Research InstituteW12 0BZUK,Institute for Materials Discovery, University College LondonRoberts BuildingLondonWC1E 7JEUK
| | | | - Dong Kuk Kim
- Department of Materials, Imperial College LondonLondonSW7 2AZUK
| | - Cecilia Mattevi
- Department of Materials, Imperial College LondonLondonSW7 2AZUK
| | - Long R. Jiao
- Department of Hepatobiliary Surgery, Division of Surgery & Cancer, Imperial College LondonHammersmith Hospital Campus, Du Cane RoadLondonW12 0NNUK
| | - Peter K. Petrov
- Department of Materials, Imperial College LondonLondonSW7 2AZUK
| | - Norbert Klein
- Department of Materials, Imperial College LondonLondonSW7 2AZUK
| |
Collapse
|
45
|
Sheta SM, El-Sheikh SM. Nanomaterials and metal-organic frameworks for biosensing applications of mutations of the emerging viruses. Anal Biochem 2022; 648:114680. [PMID: 35429447 PMCID: PMC9007753 DOI: 10.1016/j.ab.2022.114680] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2022] [Revised: 03/26/2022] [Accepted: 04/01/2022] [Indexed: 12/15/2022]
Abstract
The world today lives in a state of terrible fear due to the mutation of the emerging COVID-19. With the continuation of this pandemic, there is an urgent need for fast, accurate testing devices to detect the emerging SARS-CoV-2 pandemic in terms of biosensors and point-of-care testing. Besides, the urgent development in personal defense tools, anti-viral surfaces and wearables, and smartphones open the door for simplifying the self-diagnosis process everywhere. This review introduces a quick COVID-19 overview: definition, transmission, pathophysiology, the identification and diagnosis, mutation and transformation, and the global situation. It also focuses on an overview of the rapidly advanced technologies based on nanomaterials and MOFs for biosensing, diagnosing, and viral control of the SARS-CoV-2 pandemic. Finally, highlight the latest technologies, applications, existing achievements, and preventive diagnostic strategies to control this epidemic and combat the emerging coronavirus. This humble effort aims to provide a helpful survey that can be used to develop a creative solution and to lay down the future vision of diagnosis against COVID-19.
Collapse
Affiliation(s)
- Sheta M Sheta
- Department of Inorganic Chemistry, National Research Centre, 33 El-Behouth St., Dokki, Giza, 12622, Egypt.
| | - Said M El-Sheikh
- Department of Nanomaterials and Nanotechnology, Central Metallurgical R & D Institute, Cairo, 11421, Egypt.
| |
Collapse
|
46
|
Sivaparthipan CB, Muthu BA, Fathima G, Kumar PM, Alazab M, Díaz VG. Blockchain Assisted Disease Identification of COVID-19 Patients with the Help of IDA-DNN Classifier. WIRELESS PERSONAL COMMUNICATIONS 2022; 126:2597-2620. [PMID: 35789579 PMCID: PMC9243874 DOI: 10.1007/s11277-022-09831-7] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Accepted: 05/28/2022] [Indexed: 06/15/2023]
Abstract
Globally, millions of people were affected by the Corona-virus disease-2019 (COVID-19) causing loads of deaths. Most COVID-19 affected people recover in a few spans of weeks. However, certain people even those with a milder variant of the disease persist in experiencing symptoms subsequent to their initial recuperation. Here, a novel Block-Chain (BC)-assisted optimized deep learning algorithm, explicitly improved dragonfly algorithm based Deep Neural Network (IDA-DNN), is proposed for detecting the different diseases of the COVID-19 patients. Initially, the input data of the COVID-19 recovered patients are gathered centered on their post symptoms and their data is amassed as a BC for rendering security to the patient's data. After that, the disease identification of the patient's data is performed with the aid of system training. The training includes '4' disparate datasets for data collection, and then, performs preprocessing, Feature Extraction (FE), Feature Reduction (FR), along with classification utilizing ID-DNN on the gathered inputted data. The IDA-DNN classifies '2' classes (presence of disease and absence of disease) for every type of data. The proposed method's outcomes are examined as well as contrasted with the other prevailing techniques to corroborate that the proposed IDA-DNN detects the COVID-19 more efficiently.
Collapse
Affiliation(s)
- C. B. Sivaparthipan
- Department of Computer Science, Adhiyamaan College of Engineering, Hosur, India
| | - Bala Anand Muthu
- Department of Computer Science, Adhiyamaan College of Engineering, Hosur, India
| | - G. Fathima
- Department of Computer Science, Adhiyamaan College of Engineering, Hosur, India
| | | | - Mamoun Alazab
- IT and Environment, Charles Darwin University, Darwin, Australia
| | | |
Collapse
|
47
|
Cho H, Shim S, Cho WW, Cho S, Baek H, Lee SM, Shin DS. Electrochemical Impedance-Based Biosensors for the Label-Free Detection of the Nucleocapsid Protein from SARS-CoV-2. ACS Sens 2022; 7:1676-1684. [PMID: 35653260 PMCID: PMC9211059 DOI: 10.1021/acssensors.2c00317] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2022] [Accepted: 05/19/2022] [Indexed: 02/06/2023]
Abstract
Diagnosis of coronavirus disease (COVID-19) is important because of the emergence and global spread of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). Real-time polymerase chain reaction (PCR) is widely used to diagnose COVID-19, but it is time-consuming and requires sending samples to test centers. Thus, the need to detect antigens for rapid on-site diagnosis rather than PCR is increasing. We quantified the nucleocapsid (N) protein in SARS-CoV-2 using an electro-immunosorbent assay (El-ISA) and a multichannel impedance analyzer with a 96-interdigitated microelectrode sensor (ToAD). The El-ISA measures impedance signals from residual detection antibodies after sandwich assays and thus offers highly specific, label-free detection of the N protein with low cross-reactivity. The ToAD sensor enables the real-time electrochemical detection of multiple samples in conventional 96-well plates. The limit of detection for the N protein was 0.1 ng/mL with a detection range up to 10 ng/mL. This system did not detect signals for the S protein. While this study focused on detecting the N protein in SARS-CoV-2, our system can also be widely applicable to detecting various biomolecules involved in antigen-antibody interactions.
Collapse
Affiliation(s)
- Hana Cho
- Department
of Chemical and Biological Engineering, Sookmyung Women’s University, Yongsan-gu, Seoul 04310, Republic of Korea
- Industry
Collaboration Center, Sookmyung Women’s
University, Yongsan-gu, Seoul 04310, Republic
of Korea
| | - Suhyun Shim
- Department
of Chemical and Biological Engineering, Sookmyung Women’s University, Yongsan-gu, Seoul 04310, Republic of Korea
| | - Won Woo Cho
- Cantis
Inc., Ansan-si, Gyeonggi-do 15588, Republic of Korea
| | - Sungbo Cho
- Department
of Electronics Engineering, Gachon University, Seongnam-si, Gyeonggi-do 13120, Republic of Korea
| | - Hanseung Baek
- Comprehensive
Dental Care Center, Purme Nexon Children
Rehabilitation Hospital, Mapo-gu, Seoul 03918, Republic
of Korea
| | - Sang-Myung Lee
- Cantis
Inc., Ansan-si, Gyeonggi-do 15588, Republic of Korea
| | - Dong-Sik Shin
- Department
of Chemical and Biological Engineering, Sookmyung Women’s University, Yongsan-gu, Seoul 04310, Republic of Korea
- Industry
Collaboration Center, Sookmyung Women’s
University, Yongsan-gu, Seoul 04310, Republic
of Korea
| |
Collapse
|
48
|
Kong J, Li W, Hu J, Zhao S, Yue T, Li Z, Xia Y. The Safety of Cold-Chain Food in Post-COVID-19 Pandemic: Precaution and Quarantine. Foods 2022; 11:1540. [PMID: 35681292 PMCID: PMC9180738 DOI: 10.3390/foods11111540] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 05/03/2022] [Accepted: 05/20/2022] [Indexed: 02/04/2023] Open
Abstract
Since the outbreak of coronavirus disease-19 (COVID-19), cold-chain food contamination caused by the pathogenic severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) has attracted huge concern. Cold-chain foods provide a congenial environment for SARS-CoV-2 survival, which presents a potential risk for public health. Strengthening the SARS-CoV-2 supervision of cold-chain foods has become the top priority in many countries. Methodologically, the potential safety risks and precaution measures of SARS-CoV-2 contamination on cold-chain food are analyzed. To ensure the safety of cold-chain foods, the advances in SARS-CoV-2 detection strategies are summarized based on technical principles and target biomarkers. In particular, the techniques suitable for SARS-CoV-2 detection in a cold-chain environment are discussed. Although many quarantine techniques are available, the field-based quarantine technique on cold-chain food with characteristics of real-time, sensitive, specific, portable, and large-scale application is urgently needed.
Collapse
Affiliation(s)
- Jia Kong
- College of Food Science and Engineering, Northwest A&F University, Xianyang 712100, China; (J.K.); (W.L.); (J.H.); (S.Z.); (T.Y.); (Z.L.)
| | - Wenxin Li
- College of Food Science and Engineering, Northwest A&F University, Xianyang 712100, China; (J.K.); (W.L.); (J.H.); (S.Z.); (T.Y.); (Z.L.)
| | - Jinyao Hu
- College of Food Science and Engineering, Northwest A&F University, Xianyang 712100, China; (J.K.); (W.L.); (J.H.); (S.Z.); (T.Y.); (Z.L.)
| | - Shixuan Zhao
- College of Food Science and Engineering, Northwest A&F University, Xianyang 712100, China; (J.K.); (W.L.); (J.H.); (S.Z.); (T.Y.); (Z.L.)
| | - Tianli Yue
- College of Food Science and Engineering, Northwest A&F University, Xianyang 712100, China; (J.K.); (W.L.); (J.H.); (S.Z.); (T.Y.); (Z.L.)
- Laboratory of Quality & Safety Risk Assessment for Agro-Products, Ministry of Agriculture, Xianyang 712100, China
| | - Zhonghong Li
- College of Food Science and Engineering, Northwest A&F University, Xianyang 712100, China; (J.K.); (W.L.); (J.H.); (S.Z.); (T.Y.); (Z.L.)
- Laboratory of Quality & Safety Risk Assessment for Agro-Products, Ministry of Agriculture, Xianyang 712100, China
| | - Yinqiang Xia
- College of Food Science and Engineering, Northwest A&F University, Xianyang 712100, China; (J.K.); (W.L.); (J.H.); (S.Z.); (T.Y.); (Z.L.)
| |
Collapse
|
49
|
Sadighbayan D, Minhas-Khan A, Ghafar-Zadeh E. Laser-Induced Graphene-Functionalized Field-Effect Transistor-Based Biosensing: A Potent Candidate for COVID-19 Detection. IEEE Trans Nanobioscience 2022; 21:232-245. [PMID: 34648455 PMCID: PMC9088816 DOI: 10.1109/tnb.2021.3119996] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Revised: 07/30/2021] [Accepted: 09/29/2021] [Indexed: 11/26/2022]
Abstract
Speedy and on-time detection of coronavirus disease 2019 (COVID-19) is of high importance to control the pandemic effectively and stop its disastrous consequences. A widely available, reliable, label-free, and rapid test that can recognize tiny amounts of specific biomarkers might be the solution. Nanobiosensors are one of the most attractive candidates for this purpose. Integration of graphene with biosensing devices shifts the performance of these systems to an incomparable level. Between the various arrangements using this wonder material, field-effect transistors (FETs) display a precise detection even in complex samples. The emergence of pioneering biosensors for detecting a wide range of diseases especially COVID-19 created the incentive to prepare a review of the recent graphene-FET biosensing platforms. However, the graphene fabrication and transfer to the surface of the device is an imperative factor for researchers to take into account. Therefore, we also reviewed the common methods of manufacturing graphene for biosensing applications and discuss their advantages and disadvantages. One of the most recent synthesizing techniques - laser-induced graphene (LIG) - is attracting attention owing to its extraordinary benefits which are thoroughly explained in this article. Finally, a conclusion highlighting the current challenges is presented.
Collapse
Affiliation(s)
- Deniz Sadighbayan
- Biologically Inspired Sensors and Actuators Laboratory (BioSA)York UniversityTorontoONM3J 1P3Canada
| | - Aamir Minhas-Khan
- Biologically Inspired Sensors and Actuators Laboratory (BioSA)York UniversityTorontoONM3J 1P3Canada
| | - Ebrahim Ghafar-Zadeh
- Biologically Inspired Sensors and Actuators Laboratory (BioSA)York UniversityTorontoONM3J 1P3Canada
| |
Collapse
|
50
|
Zhang W, Liu N, Zhang J. Functional nucleic acids as modular components against SARS-CoV-2: From diagnosis to therapeutics. Biosens Bioelectron 2022; 201:113944. [PMID: 35026546 PMCID: PMC8718887 DOI: 10.1016/j.bios.2021.113944] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 11/28/2021] [Accepted: 12/28/2021] [Indexed: 01/05/2023]
Abstract
Coronavirus Disease 2019 (COVID-19), which poses an extremely serious global impact on human public healthcare, represents a high transmission and disease-causing viral infection caused by Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) that is expanding at a rapid pace. Therefore, it is urgent for researchers to establish effective platforms for the assay and treatment of SARS-CoV-2. Functional nucleic acids (FNAs), comprising aptamers and nucleases, are of primary concern within the biological and medical communities owing of the distinctive properties of their target recognition and catalysis. This review will concentrate on the essential aspects of insights regarding FNAs and their technological expertise for the diagnostic and therapeutic utilization against COVID-19. We first offer a historical perspective of the COVID-19 pandemics, its clinical characteristics and potential biomarkers. Then, we briefly discuss the current diagnostic and therapeutic methodology towards COVID-19, highlighting the superiorities and existing shortcomings. After that, we introduce the key features of FNAs, and summarize recent progress of in vitro selection of FNAs for SARS-CoV-2 specific proteins and RNAs, followed by highlighting the general concept of translating FNAs into functional probes for diagnostic and therapeutic purposes. Then, we critically review the emerging FNAs-based diagnostic and therapeutic strategies that are fast, precise, efficient, and highly specific to fight COVID-19. Finally, we identify remaining challenges and offer future outlook of this emerging field.
Collapse
Affiliation(s)
- Wenxian Zhang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Chemistry and Biomedicine Innovation Center (ChemBIC), Nanjing University, Nanjing, 210023, China
| | - Na Liu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Chemistry and Biomedicine Innovation Center (ChemBIC), Nanjing University, Nanjing, 210023, China
| | - Jingjing Zhang
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Chemistry and Biomedicine Innovation Center (ChemBIC), Nanjing University, Nanjing, 210023, China.
| |
Collapse
|