1
|
El-Tanani M, Rabbani SA, Babiker R, El-Tanani Y, Satyam SM, Porntaveetus T. Emerging Multifunctional Biomaterials for Addressing Drug Resistance in Cancer. BIOLOGY 2025; 14:497. [PMID: 40427686 DOI: 10.3390/biology14050497] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/25/2025] [Revised: 04/27/2025] [Accepted: 04/29/2025] [Indexed: 05/29/2025]
Abstract
Drug resistance remains a major barrier to effective cancer treatment, contributing to poor patient outcomes. Multifunctional biomaterials integrating electrical and catalytic properties offer a transformative strategy to target diverse resistance mechanisms. This review explores their ability to modulate cellular processes, remodel the tumor microenvironment (TME), and enhance drug delivery. Electrically active biomaterials enhance drug uptake and apoptotic sensitivity by altering membrane potentials, ion channels, and intracellular signaling, synergizing with chemotherapy. Catalytic biomaterials generate reactive oxygen species (ROS), activate prodrugs, reprogram hypoxic and acidic TME, and degrade the extracellular matrix (ECM) to improve drug penetration. Hybrid nanomaterials (e.g., conductive hydrogels, electrocatalytic nanoparticles), synergize electrical and catalytic properties for localized, stimuli-responsive therapy and targeted drug release, minimizing systemic toxicity. Despite challenges in biocompatibility and scalability, future integration with immunotherapy, personalized medicine, and intelligent self-adaptive systems capable of real-time tumor response promises to accelerate clinical translation. The development of these adaptive biomaterials, alongside advancements in nanotechnology and AI-driven platforms, represents the next frontier in precision oncology. This review highlights the potential of multifunctional biomaterials to revolutionize cancer therapy by addressing multidrug resistance at cellular, genetic, and microenvironmental levels, offering a roadmap to improve therapeutic outcomes and reshape oncology practice.
Collapse
Affiliation(s)
- Mohamed El-Tanani
- RAK College of Pharmacy, RAK Medical and Health Sciences University, Ras Al Khaimah 11172, United Arab Emirates
| | - Syed Arman Rabbani
- RAK College of Pharmacy, RAK Medical and Health Sciences University, Ras Al Khaimah 11172, United Arab Emirates
| | - Rasha Babiker
- RAK College of Medical Sciences, RAK Medical and Health Sciences University, Ras Al Khaimah 11172, United Arab Emirates
| | | | - Shakta Mani Satyam
- RAK College of Medical Sciences, RAK Medical and Health Sciences University, Ras Al Khaimah 11172, United Arab Emirates
| | - Thantrira Porntaveetus
- Center of Excellence in Precision Medicine and Digital Health, Department of Physiology, Faculty of Dentistry, Chulalongkorn University, Bangkok 10330, Thailand
| |
Collapse
|
2
|
Subawickrama Mallika Widanaarachchige N, Paul A, Banga IK, Bhide A, Muthukumar S, Prasad S. Advancements in Breathomics: Special Focus on Electrochemical Sensing and AI for Chronic Disease Diagnosis and Monitoring. ACS OMEGA 2025; 10:4187-4196. [PMID: 39959047 PMCID: PMC11822511 DOI: 10.1021/acsomega.4c10008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2024] [Revised: 01/04/2025] [Accepted: 01/08/2025] [Indexed: 02/18/2025]
Abstract
This Review examines the potential of breathomics in enhancing disease monitoring and diagnostic precision when integrated with artificial intelligence (AI) and electrochemical sensing techniques. It discusses breathomics' potential for early and noninvasive disease diagnosis with a focus on chronic kidney disease (CKD), chronic obstructive pulmonary disease (COPD), and lung cancer, which have been well studied in the context of VOC association with diseases. The noninvasive nature of exhaled breath analysis can be advantageous compared to traditional diagnostic methods for CKD, which often rely on blood and urine testing. VOC analysis can enhance spirometry and imaging methods used in COPD diagnosis, providing a more comprehensive picture of the disease's progression. Breathomics could also provide a less intrusive and potentially earlier diagnostic approach for lung cancer, which is now dependent on imaging and biopsy. The combination of breathomics, electrochemical sensing, and AI could lead to more personalized and successful treatment plans for chronic illnesses using AI algorithms to decipher complicated VOC patterns. This Review assesses the viability and effectiveness of combining breathomics with electrochemical sensors and artificial intelligence by synthesizing recent research findings and technological developments.
Collapse
Affiliation(s)
| | - Anirban Paul
- Department
of Bioengineering, University of Texas at
Dallas, Richardson, Texas 75080, United States
| | - Ivneet Kaur Banga
- Department
of Bioengineering, University of Texas at
Dallas, Richardson, Texas 75080, United States
| | - Ashlesha Bhide
- Department
of Bioengineering, University of Texas at
Dallas, Richardson, Texas 75080, United States
| | - Sriram Muthukumar
- Department
of Materials Science and Engineering, University
of Texas at Dallas, Richardson, Texas 75080, United States
- EnLiSense
LLC, 1813 Audubon Pondway, Allen, Texas 75013, United States
| | - Shalini Prasad
- Department
of Bioengineering, University of Texas at
Dallas, Richardson, Texas 75080, United States
| |
Collapse
|
3
|
Sk MS, Mwangomo R, Daniel L, Gilmore J. Solution Blow Spinning: An Emerging Nanomaterials-Based Wound-Care Technology. J Biomed Mater Res B Appl Biomater 2025; 113:e35513. [PMID: 39854136 DOI: 10.1002/jbm.b.35513] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2024] [Revised: 09/09/2024] [Accepted: 11/10/2024] [Indexed: 01/26/2025]
Abstract
Application of one-dimensional nanofibers have witnessed exponential growth over the past few decades and are still emerging with their excellent physicochemical and electrical properties. The driving force behind this intriguing transition lies in their unique high surface-to-volume ratio, ubiquitous nanodomains, improved tensile strength, and flexibility to incorporate deliberate functionalities required for specific and advanced applications. Besides numerous benefits, nanomaterials may adversely interact with biological tissues and potentially be cytotoxic and carcinogenic. However, precisely engineered design can outperform the risk with myriad benefits. Wound care technologies are evolving, and products involved in wound care management have a yearly market value of $15-22 billion. Solution blow spinning (SBS) is a facile technique to synthesize biocompatible nanofibers with scalable processing variables for multidirectional biomedical applications. SBS is feasible for a wide range of thermoplastic polymers and nanomaterials to fabricate nanocomposites. This review will focus on the relevance of SBS technology for wound care, including dressings, drug delivery, tissue engineering scaffolds, and sensors.
Collapse
Affiliation(s)
- Md Salauddin Sk
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
| | - Ruth Mwangomo
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
| | - Luke Daniel
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
| | - Jordon Gilmore
- Department of Bioengineering, Clemson University, Clemson, South Carolina, USA
| |
Collapse
|
4
|
Kong Z, Wang Y, Wang Z, Li X, Yang H, Miao M, Guo L. Electrochemical aptasensor based on a dual signal amplification strategy of 1-AP-CNHs and ROP for highly sensitive detection of ERα. Bioelectrochemistry 2024; 160:108793. [PMID: 39128408 DOI: 10.1016/j.bioelechem.2024.108793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Revised: 07/22/2024] [Accepted: 08/05/2024] [Indexed: 08/13/2024]
Abstract
Estrogen receptor alpha (ERα) serves as a crucial biomarker for early breast cancer diagnosis. In this study, we proposed an electrochemical aptasensor with nanomaterial carbon nanohorns/gold nanoparticle composites (1-AP-CNHs/AuNPs) as the substrate, and the primary amine groups on the antibody initiated the ring-opening polymerization (ROP) of monomer amino acid-ferrocene (NCA-Fc) on the electrode surface for ultrasensitive detection of ERα. The composite of 1-AP-CNHs/AuNPs not only possessed more active sites, but also increased the specific surface area of the electrode and allowed a large amount of ferrocene polymer long chains to be grafted onto the electrode surface to achieve signal amplification. Under optimal conditions, the detection limit of the method was 11.995 fg mL-1 with a detection range of 100 fg mL-1-100 ng mL-1. In addition, the biotin-streptavidin system was used to further improve the sensitivity of the sensor. Importantly, this approach could be applied for the practical detection of ERα in real samples.
Collapse
Affiliation(s)
- Ziyan Kong
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China
| | - Yilong Wang
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China
| | - Zhendong Wang
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China
| | - Xiaofei Li
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China
| | - Huaixia Yang
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China.
| | - Mingsan Miao
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China; Collaborative Innovation Center of Research and Development on the Whole Industry Chain of Yu-Yao, Henan Province, PR China.
| | - Liang Guo
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China.
| |
Collapse
|
5
|
An J, Zhang M, Fu Y, Zhang Q, Si Y, Zhang Y, Fang Y, Zhang D. Emerging electrochemical biosensors for lung cancer-associated protein biomarker and miRNA detection. Int J Biol Macromol 2024; 280:135972. [PMID: 39322139 DOI: 10.1016/j.ijbiomac.2024.135972] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2024] [Revised: 09/09/2024] [Accepted: 09/22/2024] [Indexed: 09/27/2024]
Abstract
Lung cancer remains a major driver of global morbidity and mortality, and diagnosing lung tumors early in their development is vital to maximizing treatment efficacy and patient survival. Several biomarkers, including CYFRA 21-1, NSE, ProGRP, CEA, and miRNA, have been identified as reliable indicators for early lung cancer detection and monitoring treatment progress. However, the minute changes in the levels of these biomarkers during the early stages of disease necessitate advanced detection platforms. In this space, electrochemical biosensors have currently emerged as robust tools for early lung cancer screening and diagnosis owing to their low costs, rapid responses, and superior sensitivity and selectivity. This review provides an up-to-date overview of the application of electrochemiluminescence, photoelectrochemical, and other electrochemical analytical strategies for detecting lung cancer-associated protein biomarkers, and miRNA. This review compares these techniques to provide a concise overview of the principles underlying these electrochemical analytical methods, the preparation of their components, and the performance of the resulting biosensors. Lastly, a discussion of the challenges and opportunities associated with electrochemical biosensors detection of lung cancer-associated biomarkers are provided.
Collapse
Affiliation(s)
- Jiaying An
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, PR China
| | - Miao Zhang
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, PR China
| | - Yu Fu
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, PR China
| | - Qingxiang Zhang
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, PR China
| | - Yuxin Si
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, PR China
| | - Youlin Zhang
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, PR China
| | - Yuxin Fang
- Research Center of Experimental Acupuncture Science, College of Acumox and Tuina, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, PR China; National Clinical Research Center for Chinese Medicine Acupuncture and Moxibustion, Tianjin 301617, PR China; Tianjin Key Laboratory of Modern Chinese Medicine Theory of Innovation and Application, School of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, PR China; State Key Laboratory of Chinese Medicine Modernization, Tianjin 301617, PR China.
| | - Di Zhang
- College of Pharmaceutical Engineering of Traditional Chinese Medicine, Tianjin University of Traditional Chinese Medicine, Tianjin 301617, PR China; Tianjin Key Laboratory of Intelligent and Green Pharmaceuticals for Traditional Chinese Medicine, Tianjin 301617, PR China; State Key Laboratory of Chinese Medicine Modernization, Tianjin 301617, PR China.
| |
Collapse
|
6
|
Zheng Z, Zhu R, Peng I, Xu Z, Jiang Y. Wearable and implantable biosensors: mechanisms and applications in closed-loop therapeutic systems. J Mater Chem B 2024; 12:8577-8604. [PMID: 39138981 DOI: 10.1039/d4tb00782d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/15/2024]
Abstract
This review article examines the current state of wearable and implantable biosensors, offering an overview of their biosensing mechanisms and applications. We also delve into integrating these biosensors with therapeutic systems, discussing their operational principles and incorporation into closed-loop devices. Biosensing strategies are broadly categorized into chemical sensing for biomarker detection, physical sensing for monitoring physiological conditions such as pressure and temperature, and electrophysiological sensing for capturing bioelectrical activities. The discussion extends to recent developments in drug delivery and electrical stimulation devices to highlight their significant role in closed-loop therapy. By integrating with therapeutic devices, biosensors enable the modulation of treatment regimens based on real-time physiological data. This capability enhances the patient-specificity of medical interventions, an essential aspect of personalized healthcare. Recent innovations in integrating biosensors and therapeutic devices have led to the introduction of closed-loop wearable and implantable systems capable of achieving previously unattainable therapeutic outcomes. These technologies represent a significant leap towards dynamic, adaptive therapies that respond in real-time to patients' physiological states, offering a level of accuracy and effectiveness that is particularly beneficial for managing chronic conditions. This review also addresses the challenges associated with biosensor technologies. We also explore the prospects of these technologies to address their potential to transform disease management with more targeted and personalized treatment solutions.
Collapse
Affiliation(s)
- Zeyuan Zheng
- Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA.
| | - Runjin Zhu
- Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA.
| | - Ian Peng
- Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA.
| | - Zitong Xu
- Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA.
| | - Yuanwen Jiang
- Department of Materials Science and Engineering, University of Pennsylvania, Philadelphia, PA 19104, USA.
| |
Collapse
|
7
|
Ramanathan S, Lau WJ, Goh PS, Gopinath SCB, Rawindran H, Omar MF, Ismail AF, Breadmore MC, See HH. Tailoring molecularly imprinted polymer on titanium-multiwalled carbon nanotube functionalized gold electrode for enhanced chlorophyll determination in microalgae health assessment. Mikrochim Acta 2024; 191:586. [PMID: 39251454 DOI: 10.1007/s00604-024-06662-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2024] [Accepted: 08/27/2024] [Indexed: 09/11/2024]
Abstract
A unique method for determining chlorophyll content in microalgae is devised employing a gold interdigitated electrode (G-IDE) with a 10-µm gap, augmented by a nano-molecularly imprinted polymer (nano-MIP) and a titanium dioxide/multiwalled carbon nanotube (TiO2/MWCNT) nanocomposite. The nano-MIP, produced using chlorophyll template voids, successfully trapped chlorophyll, while the TiO2/MWCNT nanocomposite, synthesized by the sol-gel technique, exhibited a consistent distribution and anatase crystalline structure. The rebinding of procured chlorophyll powder, which was used as a template for nano-MIP synthesis, was identified with a high determination coefficient (R2 = 0.9857). By combining the TiO2/MWCNT nanocomposite with nano-MIP, the G-IDE sensing method achieved a slightly better R2 value of 0.9892 for detecting chlorophyll in microalgae. The presented G-IDE sensor showed a significant threefold enhancement in chlorophyll detection compared with commercially available chlorophyll powder. It had a detection limit of 0.917 mL (v/v) and a linear range that spanned from 10-6 to 1 mL. The effectiveness of the sensor in detecting chlorophyll in microalgae was confirmed through validation of its repeatability and reusability.
Collapse
Affiliation(s)
- Santheraleka Ramanathan
- Department of Chemical and Petroleum Engineering, Faculty of Engineering, Technology and Built Environment, UCSI University, Kuala Lumpur, Malaysia.
| | - Woei Jye Lau
- Faculty of Chemical and Energy Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| | - Pei Sean Goh
- Faculty of Chemical and Energy Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| | - Subash C B Gopinath
- Center for Global Health Research, Saveetha Medical College & Hospital, Saveetha Institute of Medical and Technical Sciences (SIMATS), Thandalam, Chennai-602 105, Tamil Nadu, India
- Faculty of Chemical Engineering & Technology, Universiti Malaysia Perlis (UniMAP), 02600, Arau, Perlis, Malaysia
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, 01000, Malaysia
- Department of Technical Sciences, Western Caspian University, Baku, AZ, 1075, Azerbaijan
| | - Hemamalini Rawindran
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| | - Muhammad Firdaus Omar
- Department of Physics, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| | - Ahmad Fauzi Ismail
- Faculty of Chemical and Energy Engineering, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
- Advanced Membrane Technology Research Centre (AMTEC), Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| | - Michael C Breadmore
- Australian Centre for Research On Separation Science (ACROSS), School of Natural Sciences, University of Tasmania, Hobart, TAS, 7001, Australia
| | - Hong Heng See
- Department of Chemistry, Faculty of Science, Universiti Teknologi Malaysia, 81310 UTM Johor Bahru, Johor, Malaysia
| |
Collapse
|
8
|
López L, Martínez LM, Caicedo JR, Fernández-Vega L, Cunci L. Measurement of Neuropeptide Y in Aptamer-Modified Planar Electrodes. Electrochim Acta 2024; 488:144243. [PMID: 38654828 PMCID: PMC11034791 DOI: 10.1016/j.electacta.2024.144243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/26/2024]
Abstract
Electrochemical impedance spectroscopy (EIS) is a powerful technique for studying the interaction at electrode/solution interfaces. The adoption of EIS for obtaining analytical signals in biosensors based on aptamers is gaining popularity because of its advantageous characteristics for molecular recognition. Neuropeptide Y (NPY), the most abundant neuropeptide in the body, plays a crucial role with its stress-relieving properties. Quantitative measurement of NPY is imperative for understanding its role in these and other biological processes. Although aptamer-modified electrodes for NPY detection using EIS present a promising alternative, the correlation between the data obtained and the adsorption process on the electrodes is not fully understood. Various studies utilize the change in charge transfer resistance when employing an active redox label. In contrast, label-free measurement relies on changes in capacitance. To address these challenges, we focused on the interaction between aptamer-modified planar electrodes and their target, NPY. We proposed utilizing -ω*Zimag as the analytical signal, which facilitated the analysis of the adsorption process using an analogous Langmuir isotherm equation. This approach differs from implantable microelectrodes, which adhere to the Freundlich adsorption isotherm. Notably, our method obviates the need for a redox label and enables the detection of NPY at concentrations as low as 20 pg/mL. This methodology demonstrated exceptional selectivity, exhibiting a signal difference of over 20-to-1 against potential interfering molecules.
Collapse
Affiliation(s)
- Luis López
- Department of Chemistry, University of Puerto Rico – Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, Puerto Rico 00931, United States
| | - Lyza M. Martínez
- Department of Chemistry, Universidad Ana G. Méndez – Gurabo, Carr. 189, Km 3.3, Gurabo, Puerto Rico 00778, United States
| | - Jaileen R. Caicedo
- Department of Chemistry, University of Puerto Rico – Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, Puerto Rico 00931, United States
| | - Lauren Fernández-Vega
- Department of Chemistry, Universidad Ana G. Méndez – Gurabo, Carr. 189, Km 3.3, Gurabo, Puerto Rico 00778, United States
- Department of Chemistry, Universidad Ana G. Méndez – Cupey, 1399 Ave Ana G Mendez, Cupey, Puerto Rico 00925, United States
| | - Lisandro Cunci
- Department of Chemistry, University of Puerto Rico – Rio Piedras, 17 Ave Universidad Ste 1701, San Juan, Puerto Rico 00931, United States
| |
Collapse
|
9
|
Khanwalker M, Hatada M, LaBelle JT, Sode K. Development of an electrochemical impedance spectroscopy immunosensor for insulin monitoring employing pyrroloquinoline quinone as an ingestible redox probe. Biosens Bioelectron 2024; 250:116049. [PMID: 38290381 DOI: 10.1016/j.bios.2024.116049] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2023] [Revised: 01/03/2024] [Accepted: 01/17/2024] [Indexed: 02/01/2024]
Abstract
Contemporary electrochemical impedance spectroscopy (EIS)-based biosensors face limitations in their applicability for in vivo measurements, primarily due to the necessity of using a redox probe capable of undergoing oxidation and reduction reactions in solution. Although previous investigations have demonstrated the effectiveness of EIS-based biosensors in detecting various target analytes using potassium ferricyanide as a redox probe, its unsuitability for blood or serum measurements, attributed to its inherent toxicity, poses a significant challenge. In response to this challenge, our study adopted a unique approach, focusing on the use of ingestible materials, by exploring naturally occurring substances within the body, with a specific emphasis on pyrroloquinoline quinone (PQQ). Following an assessment of PQQ's electrochemical attributes, we conducted a comprehensive series of EIS measurements. This involved the thorough characterization of the sensor's evolution, starting from the bare electrode and progressing to the immobilization of antibodies. The sensor's performance was then evaluated through the quantification of insulin concentrations ranging from 1 pM to 100 nM. A single frequency was identified for insulin measurements, offering a pathway for potential in vivo applications by combining PQQ as a redox probe with EIS measurements. This innovative approach holds promise for advancing the field of in vivo biosensing based on the EIS method.
Collapse
Affiliation(s)
- Mukund Khanwalker
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC27599, USA
| | - Mika Hatada
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC27599, USA
| | - Jeffery T LaBelle
- Department of Bioengineering, College of Engineering Science and Technology, Grand Canyon University, Phoenix, AZ, AZ85017, USA
| | - Koji Sode
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC27599, USA.
| |
Collapse
|
10
|
Yu L, Ma X, Cao X, Zhao J. Nanostructured Polyoxometalate-Based Heterogeneous Electrode Materials for Electrochemical Sensing of Glucose. Inorg Chem 2024; 63:5952-5960. [PMID: 38497726 DOI: 10.1021/acs.inorgchem.3c04596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/19/2024]
Abstract
We exploited a tactic to obtain a low-cost, high-efficiency, pollution-free, and stable nonenzymatic polyoxometalate-based heterogeneous electrode material for electrochemical sensing of glucose. It is first followed by the countercation exchange of K2Na8[Cu4(H2O)2(PW9O34)2] (CuPOM) using cesium chloride to prepare an insoluble CuPOM (Cs-CuPOM), which exhibits a uniform and perfect claviform shape with smooth surface. Further, it was mixed with graphite powder to prepare Cs-CuPOM-modified carbon paste electrode (Cs-CuPOM/CPE) with the Cs-CuPOM content between 15% and 50% in weight. This obtained electrode material Cs-CuPOM shows a better electrochemical sensor activity than Cs-MnPOM, Cs-FePOM, and other reported POM-based electrode materials for glucose oxidation on account of their quicker electron transfer kinetics, which also exhibits conspicuous characteristics with a wide linear range of 5-1500 μM. It also possesses a high sensitivity of 16.3 A M-1 cm-2 and a low limit of detection (LOD) of 0.99 × 10-6 M at the signal-to-noise ratio of 3. The conspicuous sensing feature, low cost, and liable synthetic method can make Cs-CuPOM a promising candidate for the exploitation of a preeminent glucose sensor.
Collapse
Affiliation(s)
- Li Yu
- College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, Henan 464000, China
| | - Xiaocai Ma
- College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, Henan 464000, China
| | - Xinhua Cao
- College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, Henan 464000, China
- Hebei Provincial Key Laboratory of Photoelectric Control on Surface and Interface, Hebei University of Science and Technology, Yuhua Road 70, Shijiazhuang 050080, China
| | - Junwei Zhao
- Henan Key Laboratory of Polyoxometalate Chemistry, College of Chemistry and Molecular Sciences, Henan University, Kaifeng, Henan 475004, China
| |
Collapse
|
11
|
Sun S, Ma Q, Sheng Q, Huang S, Wu C, Liu J, Xu J. Amyloid-β Oligomer-Induced Electrophysiological Mechanisms and Electrical Impedance Changes in Neurons. SENSORS (BASEL, SWITZERLAND) 2024; 24:1211. [PMID: 38400369 PMCID: PMC10892449 DOI: 10.3390/s24041211] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Revised: 02/04/2024] [Accepted: 02/10/2024] [Indexed: 02/25/2024]
Abstract
Amyloid plays a critical role in the pathogenesis of Alzheimer's disease (AD) and can aggregate to form oligomers and fibrils in the brain. There is increasing evidence that highly toxic amyloid-β oligomers (AβOs) lead to tau protein aggregation, hyperphosphorylation, neuroinflammation, neuronal loss, synaptic loss, and dysfunction. Although the effects of AβOs on neurons have been investigated using conventional biochemical experiments, there are no established criteria for electrical evaluation. To this end, we explored electrophysiological changes in mouse hippocampal neurons (HT22) following exposure to AβOs and/or naringenin (Nar, a flavonoid compound) using electrical impedance spectroscopy (EIS). AβO-induced HT22 showed a decreased impedance amplitude and increased phase angle, and the addition of Nar reversed these changes. The characteristic frequency was markedly increased with AβO exposure, which was also reversed by Nar. The AβOs decreased intranuclear and cytoplasmic resistance and increased nucleus resistance and extracellular capacitance. Overall, the innovative construction of the eight-element CPE-equivalent circuit model further reflects that the pseudo-capacitance of the cell membrane and cell nucleus was increased in the AβO-induced group. This study conclusively revealed that AβOs induce cytotoxic effects by disrupting the resistance characteristics of unit membranes. The results further support that EIS is an effective technique for evaluating AβO-induced neuronal damage and microscopic electrical distinctions in the sub-microscopic structure of reactive cells.
Collapse
Affiliation(s)
- Shimeng Sun
- Department of Physiology and Pharmacology, Health Science Center, Ningbo University, Ningbo 315211, China; (S.S.); (Q.M.); (Q.S.); (S.H.); (C.W.)
| | - Qing Ma
- Department of Physiology and Pharmacology, Health Science Center, Ningbo University, Ningbo 315211, China; (S.S.); (Q.M.); (Q.S.); (S.H.); (C.W.)
| | - Qiyu Sheng
- Department of Physiology and Pharmacology, Health Science Center, Ningbo University, Ningbo 315211, China; (S.S.); (Q.M.); (Q.S.); (S.H.); (C.W.)
| | - Shangwei Huang
- Department of Physiology and Pharmacology, Health Science Center, Ningbo University, Ningbo 315211, China; (S.S.); (Q.M.); (Q.S.); (S.H.); (C.W.)
| | - Chenxia Wu
- Department of Physiology and Pharmacology, Health Science Center, Ningbo University, Ningbo 315211, China; (S.S.); (Q.M.); (Q.S.); (S.H.); (C.W.)
| | - Junsong Liu
- State Key Laboratory of Superhard Materials, College of Physics, Jilin University, Changchun 130012, China
| | - Jia Xu
- Department of Physiology and Pharmacology, Health Science Center, Ningbo University, Ningbo 315211, China; (S.S.); (Q.M.); (Q.S.); (S.H.); (C.W.)
| |
Collapse
|
12
|
Sitkov N, Ryabko A, Moshnikov V, Aleshin A, Kaplun D, Zimina T. Hybrid Impedimetric Biosensors for Express Protein Markers Detection. MICROMACHINES 2024; 15:181. [PMID: 38398911 PMCID: PMC10890403 DOI: 10.3390/mi15020181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 01/22/2024] [Accepted: 01/23/2024] [Indexed: 02/25/2024]
Abstract
Impedimetric biosensors represent a powerful and promising tool for studying and monitoring biological processes associated with proteins and can contribute to the development of new approaches in the diagnosis and treatment of diseases. The basic principles, analytical methods, and applications of hybrid impedimetric biosensors for express protein detection in biological fluids are described. The advantages of this type of biosensors, such as simplicity and speed of operation, sensitivity and selectivity of analysis, cost-effectiveness, and an ability to be integrated into hybrid microfluidic systems, are demonstrated. Current challenges and development prospects in this area are analyzed. They include (a) the selection of materials for electrodes and formation of nanostructures on their surface; (b) the development of efficient methods for biorecognition elements' deposition on the electrodes' surface, providing the specificity and sensitivity of biosensing; (c) the reducing of nonspecific binding and interference, which could affect specificity; (d) adapting biosensors to real samples and conditions of operation; (e) expanding the range of detected proteins; and, finally, (f) the development of biosensor integration into large microanalytical system technologies. This review could be useful for researchers working in the field of impedimetric biosensors for protein detection, as well as for those interested in the application of this type of biosensor in biomedical diagnostics.
Collapse
Affiliation(s)
- Nikita Sitkov
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
- Engineering Centre for Microtechnology and Diagnostics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| | - Andrey Ryabko
- Laboratory of Nonequilibrium Processes in Semiconductors, Ioffe Institute, 26 Politekhnicheskaya, 194021 Saint Petersburg, Russia;
| | - Vyacheslav Moshnikov
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
| | - Andrey Aleshin
- Laboratory of Nonequilibrium Processes in Semiconductors, Ioffe Institute, 26 Politekhnicheskaya, 194021 Saint Petersburg, Russia;
| | - Dmitry Kaplun
- Artificial Intelligence Research Institute, China University of Mining and Technology, 1 Daxue Road, Xuzhou 221116, China;
- Department of Automation and Control Processes, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| | - Tatiana Zimina
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
- Engineering Centre for Microtechnology and Diagnostics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| |
Collapse
|
13
|
Al-Qaoud KM, Obeidat YM, Al-Omari T, Okour M, Al-Omari MM, Ahmad MI, Alshadfan R, Rawashdeh AM. The development of an electrochemical immunosensor utilizing chicken IgY anti-spike antibody for the detection of SARS-CoV-2. Sci Rep 2024; 14:748. [PMID: 38185704 PMCID: PMC10772103 DOI: 10.1038/s41598-023-50501-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2023] [Accepted: 12/20/2023] [Indexed: 01/09/2024] Open
Abstract
This paper introduces a novel approach for detecting the SARS-CoV-2 recombinant spike protein combining a label free electrochemical impedimetric immunosensor with the use of purified chicken IgY antibodies. The sensor employs three electrodes and is functionalized with an anti-S IgY antibody, ELISA and immunoblot assays confirmed the positive response of chicken immunized with SARS-CoV2 S antigen. The developed immunosensor is effective in detecting SARS-CoV-2 in nasopharyngeal clinical samples from suspected cases. The key advantage of this biosensor is its remarkable sensitivity, and its capability of detecting very low concentrations of the target analyte, with a detection limit of 5.65 pg/mL. This attribute makes it highly suitable for practical point-of-care (POC) applications, particularly in low analyte count clinical scenarios, without requiring amplification. Furthermore, the biosensor has a wide dynamic range of detection, spanning from 11.56 to 740 ng/mL, which makes it applicable for sample analysis in a typical clinical setting.
Collapse
Affiliation(s)
- Khaled M Al-Qaoud
- Department of Biological Sciences, Faculty of Science, Yarmouk University, Irbid, Jordan
| | - Yusra M Obeidat
- Department of Electronics Engineering, Hijjawi Faculty for Engineering Technology, Yarmouk University, Irbid, Jordan.
| | - Tareq Al-Omari
- Department of Biological Sciences, Faculty of Science, Yarmouk University, Irbid, Jordan
| | - Mohammad Okour
- Department of Biological Sciences, Faculty of Science, Yarmouk University, Irbid, Jordan
| | - Mariam M Al-Omari
- Department of Basic Medical Sciences, Faculty of Medicine, Yarmouk University, Irbid, Jordan
| | - Mohammad I Ahmad
- Rawgene Biotech, Umm Khelad St. 33, Amman, Jordan
- Atlas Medical, Sahab Industrial Area, Amman, Jordan
- Department of Chemical Sciences, Faculty of Pharmacy, University of Porto, Porto, Portugal
| | - Raed Alshadfan
- Rawgene Biotech, Umm Khelad St. 33, Amman, Jordan
- Atlas Medical, Sahab Industrial Area, Amman, Jordan
| | | |
Collapse
|
14
|
Kim Y, Kang D, Kim S, Hong E, Jang M. Capacitance Contribution of NIH/3T3 Cells Existing on and between Electrodes of an Impedance Biosensor. BIOSENSORS 2023; 13:970. [PMID: 37998145 PMCID: PMC10669850 DOI: 10.3390/bios13110970] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 10/31/2023] [Accepted: 11/02/2023] [Indexed: 11/25/2023]
Abstract
In this study, an impedance biosensor capable of real-time monitoring of the growth and drug reactions using NIH/3T3 cells was fabricated through a semiconductor process. With the fabricated impedance biosensor, the cell growth and drug reaction states are monitored in real-time, showing the validness of the developed biosensor. By using the developed impedance biosensor, we have investigated the capacitance contribution of NIH/3T3 cells existing on electrodes and between electrodes. To compare the capacitance value contributions of the cells on and between electrodes, wide- and narrow-gap electrode patterns are manufactured with 3.7 and 0.3 mm electrode gap spacings, respectively. From the detailed analysis, the capacitance contributions of NIH/3T3 cells existing on electrodes are estimated around less than 20 percent compared to the cells existing between electrodes. In other words, a minimized electrode area with maximized electrode spacing is the promising impedance biosensor design guide for accurate cell capacitance measurements.
Collapse
Affiliation(s)
- Yeeun Kim
- School of Semiconductor & Display Technology, Hallym University, Chuncheon 24252, Republic of Korea; (Y.K.); (D.K.); (S.K.)
| | - Dahyun Kang
- School of Semiconductor & Display Technology, Hallym University, Chuncheon 24252, Republic of Korea; (Y.K.); (D.K.); (S.K.)
| | - Seokgyu Kim
- School of Semiconductor & Display Technology, Hallym University, Chuncheon 24252, Republic of Korea; (Y.K.); (D.K.); (S.K.)
| | - Eunchae Hong
- Department of Life Science, Hallym University, Chuncheon 24252, Republic of Korea;
| | - Moongyu Jang
- School of Semiconductor & Display Technology, Hallym University, Chuncheon 24252, Republic of Korea; (Y.K.); (D.K.); (S.K.)
- Center of Nano Convergence Technology, Hallym University, Chuncheon 24252, Republic of Korea
| |
Collapse
|
15
|
Yadav A, Patil R, Dutta S. Advanced Self-Powered Biofuel Cells with Capacitor and Nanogenerator for Biomarker Sensing. ACS APPLIED BIO MATERIALS 2023; 6:4060-4080. [PMID: 37787456 DOI: 10.1021/acsabm.3c00640] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
Self-powered biofuel cells (BFCs) have evolved for highly sensitive detection of biomarkers such as noncodon micro ribonucleic acids (miRNAs) in the presence of interfering substrates. Self-charging supercapacitive BFCs for in vivo and in vitro cellular microenvironments represent the most prevalent sensing mechanism for diagnosis. Therefore, self-powered biosensing (SPB) with a capacitor and contact separation with a triboelectric nanogenerator (TENG) offers electrochemical and colorimetric dual-mode detection via improved electrical signal intensity. In this review, we discuss three major components: stretchable self-powered BFC design, miRNA sensing, and impedance spectroscopy. A specific focus is given to 1) assembling of sensors for biomarkers, 2) electrical output signal intensification, and 3) role of supercapacitors and nanogenerators in SPBs. We outline the key features of stretchable SPBs and the sequence of miRNA sensing by SPBs. We have emphasized the need of a supercapacitor and nanogenerator for SPBs in the context of advanced assembly of the sensing unit. Finally, we outline the role of impedance spectroscopy in the detection and estimation of biomarkers. We highlight key challenges in SPBs for biomarker sensing, which needs improved sensing accuracy, integration strategies of electrochemical biosensing for in vitro and in vivo microenvironments, and the impact of miRNA sensing on cancer diagnostics. This article attempts a specific focus on the accuracy and limitations of sensing unit for miRNA biomarkers and associated tool for boosting electrical signal intensity for a potential big step further.
Collapse
Affiliation(s)
- Anubha Yadav
- Electrochemical Energy & Sensor Research Laboratory Amity Institute of Click Chemistry Research & Studies, Amity University, Sector 125, Noida 201301, Uttar Pradesh, India
| | - Rahul Patil
- Electrochemical Energy & Sensor Research Laboratory Amity Institute of Click Chemistry Research & Studies, Amity University, Sector 125, Noida 201301, Uttar Pradesh, India
| | - Saikat Dutta
- Electrochemical Energy & Sensor Research Laboratory Amity Institute of Click Chemistry Research & Studies, Amity University, Sector 125, Noida 201301, Uttar Pradesh, India
| |
Collapse
|
16
|
Saeidi M, Chenani H, Orouji M, Adel Rastkhiz M, Bolghanabadi N, Vakili S, Mohamadnia Z, Hatamie A, Simchi A(A. Electrochemical Wearable Biosensors and Bioelectronic Devices Based on Hydrogels: Mechanical Properties and Electrochemical Behavior. BIOSENSORS 2023; 13:823. [PMID: 37622909 PMCID: PMC10452289 DOI: 10.3390/bios13080823] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/30/2023] [Revised: 07/20/2023] [Accepted: 08/04/2023] [Indexed: 08/26/2023]
Abstract
Hydrogel-based wearable electrochemical biosensors (HWEBs) are emerging biomedical devices that have recently received immense interest. The exceptional properties of HWEBs include excellent biocompatibility with hydrophilic nature, high porosity, tailorable permeability, the capability of reliable and accurate detection of disease biomarkers, suitable device-human interface, facile adjustability, and stimuli responsive to the nanofiller materials. Although the biomimetic three-dimensional hydrogels can immobilize bioreceptors, such as enzymes and aptamers, without any loss in their activities. However, most HWEBs suffer from low mechanical strength and electrical conductivity. Many studies have been performed on emerging electroactive nanofillers, including biomacromolecules, carbon-based materials, and inorganic and organic nanomaterials, to tackle these issues. Non-conductive hydrogels and even conductive hydrogels may be modified by nanofillers, as well as redox species. All these modifications have led to the design and development of efficient nanocomposites as electrochemical biosensors. In this review, both conductive-based and non-conductive-based hydrogels derived from natural and synthetic polymers are systematically reviewed. The main synthesis methods and characterization techniques are addressed. The mechanical properties and electrochemical behavior of HWEBs are discussed in detail. Finally, the prospects and potential applications of HWEBs in biosensing, healthcare monitoring, and clinical diagnostics are highlighted.
Collapse
Affiliation(s)
- Mohsen Saeidi
- Department of Materials Science and Engineering, Sharif University of Technology, Tehran 14588-89694, Iran; (H.C.); (M.O.); (M.A.R.); (N.B.)
| | - Hossein Chenani
- Department of Materials Science and Engineering, Sharif University of Technology, Tehran 14588-89694, Iran; (H.C.); (M.O.); (M.A.R.); (N.B.)
| | - Mina Orouji
- Department of Materials Science and Engineering, Sharif University of Technology, Tehran 14588-89694, Iran; (H.C.); (M.O.); (M.A.R.); (N.B.)
| | - MahsaSadat Adel Rastkhiz
- Department of Materials Science and Engineering, Sharif University of Technology, Tehran 14588-89694, Iran; (H.C.); (M.O.); (M.A.R.); (N.B.)
| | - Nafiseh Bolghanabadi
- Department of Materials Science and Engineering, Sharif University of Technology, Tehran 14588-89694, Iran; (H.C.); (M.O.); (M.A.R.); (N.B.)
| | - Shaghayegh Vakili
- Polymer Research Laboratory, Department of Chemistry, Faculty of Science, University of Zanjan, Zanjan 45371-38791, Iran;
| | - Zahra Mohamadnia
- Department of Chemistry, Institute for Advanced Studies in Basic Science (IASBS), Gava Zang, Zanjan 45137-66731, Iran;
| | - Amir Hatamie
- Department of Chemistry, Institute for Advanced Studies in Basic Science (IASBS), Gava Zang, Zanjan 45137-66731, Iran;
- Department of Chemistry and Molecular Biology, University of Gothenburg, 405 30 Gothenburg, Sweden
| | - Abdolreza (Arash) Simchi
- Department of Materials Science and Engineering, Sharif University of Technology, Tehran 14588-89694, Iran; (H.C.); (M.O.); (M.A.R.); (N.B.)
- Institute for Nanoscience and Nanotechnology, Sharif University of Technology, Tehran 14588-89694, Iran
| |
Collapse
|
17
|
Hao Z, Sun X, Chen J, Zhou X, Zhang Y. Recent Progress and Challenges in Faradic Capacitive Desalination: From Mechanism to Performance. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2300253. [PMID: 37093194 DOI: 10.1002/smll.202300253] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/10/2023] [Revised: 02/16/2023] [Indexed: 05/03/2023]
Abstract
Due to substantial consumption and widespread contamination of the available freshwater resources, green, economical, and sustainable water recycling technologies are urgently needed. Recently, Faradic capacitive deionization (CDI), an emerging desalination technology, has shown great desalination potential due to its high salt removal ability, low consumption, and hardly any co-ion exclusion effect. However, the ion removal mechanisms and structure-property relationships of Faradic CDI are still unclear. Therefore, it is necessary to summarize the current research progress and challenges of Faradic CDI. In this review, the recent progress of Faradic CDI from five aspects is systematically reviewed: cell architectures, desalination mechanisms, evaluation indicators, operation modes, and electrode materials. The working mechanisms of Faradic CDI are classified as insertion reaction, conversion reaction, ion-redox species interaction, and ion-redox couple interaction in the electrolytes. The intrinsic and desalination properties of a series of Na+ and Cl- capturing materials are described in detail in terms of design concepts, structural analysis, and synthesis modulation. In addition, the effects of different cell architectures, operation modes, and electrode materials on the desalination performance of Faradic CDI are also investigated. Finally, the work summarizes the challenges remaining in Faradic CDI and provides the prospects and directions for future development.
Collapse
Affiliation(s)
- Zewei Hao
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Xiaoqi Sun
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Jiabin Chen
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Xuefei Zhou
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Yalei Zhang
- State Key Laboratory of Pollution Control and Resources Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| |
Collapse
|
18
|
Yunus G, Singh R, Raveendran S, Kuddus M. Electrochemical biosensors in healthcare services: bibliometric analysis and recent developments. PeerJ 2023; 11:e15566. [PMID: 37397018 PMCID: PMC10312160 DOI: 10.7717/peerj.15566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2023] [Accepted: 05/24/2023] [Indexed: 07/04/2023] Open
Abstract
Biosensors are nowadays being used in various fields including disease diagnosis and clinical analysis. The ability to detect biomolecules associated with disease is vital not only for accurate diagnosis of disease but also for drug discovery and development. Among the different types of biosensors, electrochemical biosensor is most widely used in clinical and health care services especially in multiplex assays due to its high susceptibility, low cost and small in size. This article includes comprehensive review of biosensors in medical field with special emphasis on electrochemical biosensors for multiplex assays and in healthcare services. Also, the publications on electrochemical biosensors are increasing rapidly; therefore, it is crucial to be aware of any latest developments or trends in this field of research. We used bibliometric analyses to summarize the progress of this research area. The study includes global publication counts on electrochemical biosensors for healthcare along with various bibliometric data analyses by VOSviewer software. The study also recognizes the top authors and journals in the related area, and determines proposal for monitoring research.
Collapse
Affiliation(s)
- Ghazala Yunus
- Department of Basic Science, University of Hail, Hail, Saudi Arabia
| | - Rachana Singh
- Amity Institute of Biotechnology, Amity University Uttar Pradesh, Lucknow, Uttar Pradesh, India
| | - Sindhu Raveendran
- Department of Food Technology, TKM Institute of Technology, Kollam, Kerala, India
| | - Mohammed Kuddus
- Department of Biochemistry, College of Medicine, University of Ha’il, Hail, Saudi Arabia
| |
Collapse
|
19
|
Wang C, Liu A, Chen J, Liu S, Wei W. Sensitive detection of PARP-1 activity by electrochemical impedance spectroscopy based on biomineralization. Anal Chim Acta 2023; 1249:340937. [PMID: 36868772 DOI: 10.1016/j.aca.2023.340937] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2023] [Revised: 01/27/2023] [Accepted: 02/02/2023] [Indexed: 02/08/2023]
Abstract
Poly(ADP)ribose polymerase-1 (PARP-1) has attracted much attention as a tumor marker in recent years. Based on the large negative charge and hyperbranched structure of PARP-1 amplified products (PAR), many detection methods have been established. Herein, we proposed a label-free electrochemical impedance detection method based on the large amount of phosphate groups (PO43-) on the surface of PAR. Although EIS method has high sensitivity, it is not sensitive enough to discern PAR effectively. Therefore, biomineralization was incorporated to increase the resistance value (Rct) distinctly because of the poor electrical conductivity of CaP. During biomineralization process, plentiful Ca2+ was captured by PO43- of PAR through electrostatic interaction, resulting in an increasing Rct of modified ITO electrode. In contrast, when PRAP-1 was absent, only a little Ca2+ was adsorbed on the phosphate backbone of the activating dsDNA. As a result, the biomineralization effect was slight and only a negligible Rct change occurred. Experiment results showed that Rct was associated closely with the activity of PARP-1. There was a linear correlation between them when the activity value was in the range of 0.005-1.0 U. The calculated detection limit was 0.003 U. Results of real samples detection and the recovery experiments were satisfactory, indicating the method has an excellent application prospect.
Collapse
Affiliation(s)
- Chenchen Wang
- Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, State Key Laboratory of Bioelectronics, Key Laboratory of Environmental Medicine Engineering of Ministry of Education, School of Chemistry and Chemical Engineering, Southeast University, Nanjing, 211189, China
| | - Anran Liu
- Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, State Key Laboratory of Bioelectronics, Key Laboratory of Environmental Medicine Engineering of Ministry of Education, School of Chemistry and Chemical Engineering, Southeast University, Nanjing, 211189, China
| | - Jin Chen
- The Key Laboratory of Modern Toxicology of Ministry of Education, Nanjing Medical University, Nanjing, 211166, Jiangsu, China
| | - Songqin Liu
- Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, State Key Laboratory of Bioelectronics, Key Laboratory of Environmental Medicine Engineering of Ministry of Education, School of Chemistry and Chemical Engineering, Southeast University, Nanjing, 211189, China
| | - Wei Wei
- Jiangsu Engineering Laboratory of Smart Carbon-Rich Materials and Device, State Key Laboratory of Bioelectronics, Key Laboratory of Environmental Medicine Engineering of Ministry of Education, School of Chemistry and Chemical Engineering, Southeast University, Nanjing, 211189, China.
| |
Collapse
|
20
|
Kumar RR, Kumar A, Chuang CH, Shaikh MO. Recent Advances and Emerging Trends in Cancer Biomarker Detection Technologies. Ind Eng Chem Res 2023. [DOI: 10.1021/acs.iecr.2c04097] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/05/2023]
Affiliation(s)
- Rajkumar Rakesh Kumar
- Institute of Medical Science and Technology, National Sun Yat-sen University, Kaohsiung 80424, Taiwan
| | - Amit Kumar
- Institute of Medical Science and Technology, National Sun Yat-sen University, Kaohsiung 80424, Taiwan
| | - Cheng-Hsin Chuang
- Institute of Medical Science and Technology, National Sun Yat-sen University, Kaohsiung 80424, Taiwan
| | - Muhammad Omar Shaikh
- Sustainability Science and Management, Tunghai University, Taichung 407224, Taiwan
| |
Collapse
|
21
|
Didier CM, Orrico JF, Cepeda Torres OS, Castro JM, Baksh A, Rajaraman S. Microfabricated polymer-metal biosensors for multifarious data collection from electrogenic cellular models. MICROSYSTEMS & NANOENGINEERING 2023; 9:22. [PMID: 36875634 PMCID: PMC9974480 DOI: 10.1038/s41378-023-00488-1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 12/19/2022] [Accepted: 01/09/2023] [Indexed: 05/28/2023]
Abstract
Benchtop tissue cultures have become increasingly complex in recent years, as more on-a-chip biological technologies, such as microphysiological systems (MPS), are developed to incorporate cellular constructs that more accurately represent their respective biological systems. Such MPS have begun facilitating major breakthroughs in biological research and are poised to shape the field in the coming decades. These biological systems require integrated sensing modalities to procure complex, multiplexed datasets with unprecedented combinatorial biological detail. In this work, we expanded upon our polymer-metal biosensor approach by demonstrating a facile technology for compound biosensing that was characterized through custom modeling approaches. As reported herein, we developed a compound chip with 3D microelectrodes, 3D microfluidics, interdigitated electrodes (IDEs) and a microheater. The chip was subsequently tested using the electrical/electrochemical characterization of 3D microelectrodes with 1 kHz impedance and phase recordings and IDE-based high-frequency (~1 MHz frequencies) impedimetric analysis of differential localized temperature recordings, both of which were modeled through equivalent electrical circuits for process parameter extraction. Additionally, a simplified antibody-conjugation strategy was employed for a similar IDE-based analysis of the implications of a key analyte (l-glutamine) binding to the equivalent electrical circuit. Finally, acute microfluidic perfusion modeling was performed to demonstrate the ease of microfluidics integration into such a polymer-metal biosensor platform for potential complimentary localized chemical stimulation. Overall, our work demonstrates the design, development, and characterization of an accessibly designed polymer-metal compound biosensor for electrogenic cellular constructs to facilitate comprehensive MPS data collection.
Collapse
Affiliation(s)
- Charles M. Didier
- NanoScience Technology Center, University of Central Florida, 4353 Scorpius Street, Research I, Suite 231, FL 32816 Orlando, USA
- Burnett School of Biomedical Sciences, University of Central Florida, 6900 Lake Nona Blvd, FL 32827 Orlando, USA
| | - Julia F. Orrico
- NanoScience Technology Center, University of Central Florida, 4353 Scorpius Street, Research I, Suite 231, FL 32816 Orlando, USA
| | - Omar S. Cepeda Torres
- NanoScience Technology Center, University of Central Florida, 4353 Scorpius Street, Research I, Suite 231, FL 32816 Orlando, USA
- Department of Biomedical Engineering, Polytechnic University of Puerto Rico, 377, 00918, Ponce de Leon, San Juan, Puerto Rico
| | - Jorge Manrique Castro
- NanoScience Technology Center, University of Central Florida, 4353 Scorpius Street, Research I, Suite 231, FL 32816 Orlando, USA
- Department of Electrical and Computer Engineering, University of Central Florida, 4238 Scorpius Street, FL 32816 Orlando, USA
| | - Aliyah Baksh
- NanoScience Technology Center, University of Central Florida, 4353 Scorpius Street, Research I, Suite 231, FL 32816 Orlando, USA
| | - Swaminathan Rajaraman
- NanoScience Technology Center, University of Central Florida, 4353 Scorpius Street, Research I, Suite 231, FL 32816 Orlando, USA
- Burnett School of Biomedical Sciences, University of Central Florida, 6900 Lake Nona Blvd, FL 32827 Orlando, USA
- Department of Electrical and Computer Engineering, University of Central Florida, 4238 Scorpius Street, FL 32816 Orlando, USA
- Department of Materials Science and Engineering, University of Central Florida, 12760 Pegasus Drive, Engineering I, Suite 207, FL 32816 Orlando, USA
| |
Collapse
|
22
|
Redox-labelled detection probe enabled immunoassay for simultaneous detection of multiple cancer biomarkers. Mikrochim Acta 2023; 190:86. [PMID: 36757491 DOI: 10.1007/s00604-023-05663-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Accepted: 01/15/2023] [Indexed: 02/10/2023]
Abstract
Some of the cancer biomarkers often lack specificity and sensitivity; thus, simultaneous detection of multiple biomarkers can make the diagnosis more accurate. Also, simple sensing system without utilization of extra reagents like mediator or substrate during detection event is desirable for point-of-care testing. To address this, mediator and substrate-free amperometric biosensor for simultaneous detection of cancer biomarkers carcinoembryonic antigen (CEA) and alpha-fetoprotein (AFP) have been demonstrated by designing two different redox-labelled detection probes. Colloidal nanoparticles of polyaniline-pectin conjugated with AFP antibody along with ferrocene and silver nanoparticles conjugated with CEA antibody along with anthraquinone were used as redox probes to bind with AFP and CEA during the detection event. Sensor constructed using carboxylic acid tethered polyaniline as immobilization matrix displayed 5 times wider linear range than conventional polyaniline for AFP and CEA detection by sandwich electrochemical assay. The detection limit was 30 pg mL-1 for AFP and 80 pg mL-1 for CEA. The biosensor displayed appropriate sensitivity, good specificity, and negligible cross-reactivity between the two targets. The proposed sensor was used to determine APF and CEA in human blood serum. The strategy demonstrated can be further extended for detection of panel of cancer biomarkers by designing appropriate redox probes.
Collapse
|
23
|
Olean-Oliveira A, Trevizan HF, Cardoso CX, Teixeira MF. Impedimetric study of the electrocatalytic oxidation of alcohols by nickel-Schiff base metallopolymer: Potential application for forensic identification of alcoholic beverage contaminants by multivariate data analysis. Talanta 2023. [DOI: 10.1016/j.talanta.2022.124029] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
24
|
Dong T, Matos Pires NM, Yang Z, Jiang Z. Advances in Electrochemical Biosensors Based on Nanomaterials for Protein Biomarker Detection in Saliva. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2023; 10:e2205429. [PMID: 36585368 PMCID: PMC9951322 DOI: 10.1002/advs.202205429] [Citation(s) in RCA: 35] [Impact Index Per Article: 17.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/19/2022] [Revised: 11/20/2022] [Indexed: 06/02/2023]
Abstract
The focus on precise medicine enhances the need for timely diagnosis and frequent monitoring of chronic diseases. Moreover, the recent pandemic of severe acute respiratory syndrome coronavirus 2 poses a great demand for rapid detection and surveillance of viral infections. The detection of protein biomarkers and antigens in the saliva allows rapid identification of diseases or disease changes in scenarios where and when the test response at the point of care is mandated. While traditional methods of protein testing fail to provide the desired fast results, electrochemical biosensors based on nanomaterials hold perfect characteristics for the detection of biomarkers in point-of-care settings. The recent advances in electrochemical sensors for salivary protein detection are critically reviewed in this work, with emphasis on the role of nanomaterials to boost the biosensor analytical performance and increase the reliability of the test in human saliva samples. Furthermore, this work identifies the critical factors for further modernization of the nanomaterial-based electrochemical sensors, envisaging the development and implementation of next-generation sample-in-answer-out systems.
Collapse
Affiliation(s)
- Tao Dong
- Department of Microsystems‐ IMSFaculty of TechnologyNatural Sciences and Maritime SciencesUniversity of South‐Eastern Norway‐USNP.O. Box 235Kongsberg3603Norway
| | - Nuno Miguel Matos Pires
- Chongqing Key Laboratory of Micro‐Nano Systems and Intelligent TransductionCollaborative Innovation Center on Micro‐Nano Transduction and Intelligent Eco‐Internet of ThingsChongqing Key Laboratory of Colleges and Universities on Micro‐Nano Systems Technology and Smart TransducingNational Research Base of Intelligent Manufacturing ServiceChongqing Technology and Business UniversityNan'an DistrictChongqing400067China
| | - Zhaochu Yang
- Chongqing Key Laboratory of Micro‐Nano Systems and Intelligent TransductionCollaborative Innovation Center on Micro‐Nano Transduction and Intelligent Eco‐Internet of ThingsChongqing Key Laboratory of Colleges and Universities on Micro‐Nano Systems Technology and Smart TransducingNational Research Base of Intelligent Manufacturing ServiceChongqing Technology and Business UniversityNan'an DistrictChongqing400067China
| | - Zhuangde Jiang
- Chongqing Key Laboratory of Micro‐Nano Systems and Intelligent TransductionCollaborative Innovation Center on Micro‐Nano Transduction and Intelligent Eco‐Internet of ThingsChongqing Key Laboratory of Colleges and Universities on Micro‐Nano Systems Technology and Smart TransducingNational Research Base of Intelligent Manufacturing ServiceChongqing Technology and Business UniversityNan'an DistrictChongqing400067China
- State Key Laboratory for Manufacturing Systems EngineeringInternational Joint Laboratory for Micro/Nano Manufacturing and Measurement TechnologyXi'an Jiaotong UniversityXi'an710049China
| |
Collapse
|
25
|
Construction of lncRNA TYMSOS/hsa-miR-101-3p/CEP55 and TYMSOS/hsa-miR-195-5p/CHEK1 Axis in Non-small Cell Lung Cancer. Biochem Genet 2022; 61:995-1014. [DOI: 10.1007/s10528-022-10299-0] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Accepted: 10/21/2022] [Indexed: 11/10/2022]
|
26
|
Li J, Wang Y, Wang B, Lou J, Ni P, Jin Y, Chen S, Duan G, Zhang R. Application of CRISPR/Cas Systems in the Nucleic Acid Detection of Infectious Diseases. Diagnostics (Basel) 2022; 12:2455. [PMID: 36292145 PMCID: PMC9600689 DOI: 10.3390/diagnostics12102455] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2022] [Revised: 09/21/2022] [Accepted: 10/04/2022] [Indexed: 11/24/2022] Open
Abstract
The CRISPR/Cas system is a protective adaptive immune system against attacks from foreign mobile genetic elements. Since the discovery of the excellent target-specific sequence recognition ability of the CRISPR/Cas system, the CRISPR/Cas system has shown excellent performance in the development of pathogen nucleic-acid-detection technology. In combination with various biosensing technologies, researchers have made many rapid, convenient, and feasible innovations in pathogen nucleic-acid-detection technology. With an in-depth understanding and development of the CRISPR/Cas system, it is no longer limited to CRISPR/Cas9, CRISPR/Cas12, and other systems that had been widely used in the past; other CRISPR/Cas families are designed for nucleic acid detection. We summarized the application of CRISPR/Cas-related technology in infectious-disease detection and its development in SARS-CoV-2 detection.
Collapse
Affiliation(s)
- Junwei Li
- International School of Public Health and One Health, First Affiliated Hospital of Hainan Medical University, Haikou 570102, China
- Department of Epidemiology, College of Public Health, Zhengzhou University, Zhengzhou 450001, China
| | - Yuexia Wang
- Department of Epidemiology, College of Public Health, Zhengzhou University, Zhengzhou 450001, China
| | - Bin Wang
- Department of Epidemiology, College of Public Health, Zhengzhou University, Zhengzhou 450001, China
| | - Juan Lou
- Department of Epidemiology, College of Public Health, Zhengzhou University, Zhengzhou 450001, China
| | - Peng Ni
- Department of Epidemiology, College of Public Health, Zhengzhou University, Zhengzhou 450001, China
| | - Yuefei Jin
- Department of Epidemiology, College of Public Health, Zhengzhou University, Zhengzhou 450001, China
| | - Shuaiyin Chen
- Department of Epidemiology, College of Public Health, Zhengzhou University, Zhengzhou 450001, China
| | - Guangcai Duan
- Department of Epidemiology, College of Public Health, Zhengzhou University, Zhengzhou 450001, China
| | - Rongguang Zhang
- International School of Public Health and One Health, First Affiliated Hospital of Hainan Medical University, Haikou 570102, China
- Department of Epidemiology, College of Public Health, Zhengzhou University, Zhengzhou 450001, China
| |
Collapse
|
27
|
da Silva Junior AG, Frias IAM, Lima-Neto RG, Franco OL, Oliveira MDL, Andrade CAS. Electrochemical detection of gram-negative bacteria through mastoparan-capped magnetic nanoparticle. Enzyme Microb Technol 2022; 160:110088. [PMID: 35777193 DOI: 10.1016/j.enzmictec.2022.110088] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2022] [Revised: 05/09/2022] [Accepted: 06/16/2022] [Indexed: 12/29/2022]
Abstract
The increasing number of multidrug resistance microorganisms is an alarming threat, and their rapid detection is essential to prevent nosocomial, foodborne, or waterborne infections. Many peptides derived from the venom of wasp Synoeca surinama have antimicrobial activity against Gram-positive and Gram-negative bacteria. Synoeca-MP, an antimicrobial peptide (AMP) from mastoparan family, seems to increase bacterial membrane permeability, promoting cytotoxicity and membrane disruption. Here Synoeca-MP was evaluated as biorecognition element tethered over chitosan-coated magnetic nanoparticles (Fe3O4-Chit). The transducing layer of the biosensor was developed from the self-assembling of 4-mercaptobenzoic acid (4-MBA) monolayer onto gold substrate. Atomic force microscopy (AFM) analyses confirmed the biointeraction between AMP and different pathogens membranes. The fabrication and performance of the biosensing assembly were characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Detection of Enterococcus faecalis (G+), Klebsiella pneumoniae (G-), Pseudomonas aeruginosa (G-), and Candida tropicalis was assessed in a recognition range from 101 to 105 CFU.mL-1. An instrumental limit of detection of 10 CFU.mL-1 was obtained for each specimen. However, the device presented a preferential selectivity towards Gram-negative bacteria. The proposed biosensor is a sensitive, fast, and straightforward platform for microbial detection in aqueous samples, envisaged for environmental monitoring applications.
Collapse
Affiliation(s)
- Alberto G da Silva Junior
- Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil; Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil
| | - Isaac A M Frias
- Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil; Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil
| | - Reginaldo G Lima-Neto
- Centro de Ciências da Saúde, Departamento de Medicina Tropical, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil
| | - Octávio L Franco
- Centro de Análises Proteômicas e Bioquímicas de Brasília, Pos-Graduação em Ciências Genômicas e Biotecnologia, Universidade Católica de Brasília, Brasília, DF, Brazil; S-Inova Biotech, Pos-Graduação em Biotecnologia, Universidade Católica Dom Bosco, MS, Brazil
| | - Maria D L Oliveira
- Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil; Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil
| | - César A S Andrade
- Programa de Pós-Graduação em Inovação Terapêutica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil; Laboratório de Biodispositivos Nanoestruturados, Departamento de Bioquímica, Universidade Federal de Pernambuco, 50670-901 Recife, PE, Brazil.
| |
Collapse
|
28
|
Role of anion size in the electrochemical performance of a Poly(thionine) redox conductive polymer using electrochemical impedance spectroscopy. POLYMER 2022. [DOI: 10.1016/j.polymer.2022.125291] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
|
29
|
Wang H, Wang X, Cheng J. Bionic Enzyme-Assisted Ion-Selective Amperometric Biosensor Based on 3D Porous Conductive Matrix for Point-of-Care Nitrite Testing. ACS NANO 2022; 16:14849-14859. [PMID: 36099397 DOI: 10.1021/acsnano.2c05752] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Nitrite plays a critical role in a variety of physiological processes and maintaining the nitrite level in an appropriate range is vital to keep healthy. Current nitrite analysis methods lack sensitivity and require tedious operations, which could not meet the need of point-of-care (POC) nitrite detection in precision medicine. Here we present a cyanocobalamin (VB12) bionic enzyme-assisted ion-selective amperometric biosensor based on 3D porous conductive matrix (PCM), which can facilitate rapid and accurate POC nitrite monitoring in complex biofluids. The experimental findings quantitatively demonstrate that the biosensor has a sensitivity of 64.08 μA/(mM·cm2), a wide linear range of 0.025-45 mM, and low limit of detection of 1 nM. Moreover, the developed VB12/BSA-PCM biosensor shows outstanding stability after 21 days with 2% decline in current signal, and high repeatability between batches with RSD of only 1.29%. Real salivary nitrite detection has been evaluated, and the results match well with the commercial nitrite analyzer. Thus, the bionic enzyme-assisted ion-selective amperometric biosensor proposed herein has potential utility as an affordable tool for POC detection and home-based healthcare.
Collapse
Affiliation(s)
- Han Wang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
| | - Xueqi Wang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
| | - Jing Cheng
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, 100084, China
- National Engineering Research Center for Beijing Biochip Technology, Beijing, 102206, China
| |
Collapse
|
30
|
Construction of electrochemiluminescence biosensor via click chemistry and ARGET-ATRP for detecting tobacco mosaic virus RNA. Anal Biochem 2022; 655:114834. [DOI: 10.1016/j.ab.2022.114834] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 06/21/2022] [Accepted: 07/22/2022] [Indexed: 11/17/2022]
|
31
|
Ma Y, Li M, Pang K, Zhao M. Dual-Modulated Heterojunctions for Anti-Interference Sensing of Heavy Metals in Seawater. Anal Chem 2022; 94:10183-10191. [PMID: 35776919 DOI: 10.1021/acs.analchem.2c01644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
Abstract
Trace analyte detection in a complex environment such as in seawater is usually challenging for classic redox-based electrochemical sensors since the matrix effect of high salinity and various interfering species with similar redox properties can generate false positive/negative signals, thus impacting the sensitivity and specificity of the sensors. In this work, unlike redox-based approaches, we propose a novel sensing mode that relies on dual-modulated interfacial energy barriers of heterojunctions. By constructing the hierarchical structure of Ni/TiO2/porous-reduced graphene oxide/chitosan (CS), we introduce interfacial energy barriers of Schottky junctions into the electrochemical sensors for Cu2+. Most importantly, we found that two factors, light and the electrostatic interactions between the heterojunctions and Cu2+, can be coupled to regulate the height of the interfacial energy barrier and at last exponentially magnify the sensing signals in response to Cu2+. Since the electrostatic interaction is inert to redox, the proposed sensor is robust against most interfering species even in seawater. Illumination further enhances its sensitivity by 6.23 times and endows it a limit of detection of 0.22 nM. Such a dual-modulated sensing mode is also valid in other heterojunctions such as in the p-n junctions of Ni/NiO/MoS2/CS, demonstrating its potential in more universal applications.
Collapse
Affiliation(s)
- Ye Ma
- School of Material Science and Engineering, Ocean University of China, 238 Songling Road, Qingdao, Shandong 266100, China
| | - Ming Li
- School of Material Science and Engineering, Ocean University of China, 238 Songling Road, Qingdao, Shandong 266100, China
| | - Kun Pang
- School of Material Science and Engineering, Ocean University of China, 238 Songling Road, Qingdao, Shandong 266100, China
| | - Minggang Zhao
- School of Material Science and Engineering, Ocean University of China, 238 Songling Road, Qingdao, Shandong 266100, China
| |
Collapse
|
32
|
Wang WJ, Chou MC, Lee YJ, Hsu WL, Wang GJ. A simple electrochemical immunosensor based on a gold nanoparticle monolayer electrode for neutrophil gelatinase-associated lipocalin detection. Talanta 2022; 246:123530. [DOI: 10.1016/j.talanta.2022.123530] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 04/23/2022] [Accepted: 05/04/2022] [Indexed: 01/23/2023]
|
33
|
Zhang Y, Li P, Hou M, Chen L, Wang J, Yang H, Feng W. An electrochemical biosensor based on ARGET ATRP with DSN-assisted target recycling for sensitive detection of tobacco mosaic virus RNA. Bioelectrochemistry 2022; 144:108037. [PMID: 34906819 DOI: 10.1016/j.bioelechem.2021.108037] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Revised: 12/04/2021] [Accepted: 12/06/2021] [Indexed: 11/26/2022]
Abstract
Herein, an electrochemical biosensor for detecting tobacco mosaic virus (TMV) RNA is constructed by activator regenerated by electron transfer atom transfer radical polymerization (ARGET ATRP) combined with duplex-specific nuclease (DSN)-assisted target recycling. First, the captured DNA (cDNA) is self-assembled on the electrode surface and hybridizes with the TMV RNA (tRNA) to form cDNA/tRNA hybrids. And then the initiator of ARGET ATRP (α-bromoisobutyric acid, BMP) is attached to the cDNA via an amide bond and later triggers ARGET ATRP. Many electroactive monomers (ferrocenylmethyl methacrylate, FMMA) are polymerized and a remarkable electrical signal response of ferrocene (Fc) is obtained. However, with the present of DSN, DSN cleaves the cDNA/tRNA hybrid and releases tRNA to hybridize with another cDNA, thereby causing significant shortening of the length of the cDNA. The number of polymer chains on the electrode surface is drastically reduced, which is followed by a noticeable reduction in the signal of Fc. The method shows high sensitivity, superior selectivity, excellent stability and good reproducibility under optimal conditions with the limit of detection (LOD) of 2.9 fM. Furthermore, the biosensor showed satisfactory applicability in detecting tRNA in real samples, thereby demonstrating the potential of the method for practical TMV RNA detection.
Collapse
Affiliation(s)
- Yaping Zhang
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China
| | - Peipei Li
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China
| | - Mengyuan Hou
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China
| | - Luyao Chen
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China
| | - Jianfeng Wang
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China.
| | - Huaixia Yang
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China.
| | - Weisheng Feng
- Pharmacy College, Henan University of Chinese Medicine, Zhengzhou 450046, PR China.
| |
Collapse
|
34
|
Piedimonte P, Sola L, Cretich M, Gori A, Chiari M, Marchisio E, Borga P, Bertacco R, Melloni A, Ferrari G, Sampietro M. Differential Impedance Sensing platform for high selectivity antibody detection down to few counts: A case study on Dengue Virus. Biosens Bioelectron 2022; 202:113996. [DOI: 10.1016/j.bios.2022.113996] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 01/03/2022] [Accepted: 01/10/2022] [Indexed: 11/02/2022]
|
35
|
Sabzehmeidani MM, Kazemzad M. Quantum dots based sensitive nanosensors for detection of antibiotics in natural products: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2022; 810:151997. [PMID: 34848263 DOI: 10.1016/j.scitotenv.2021.151997] [Citation(s) in RCA: 31] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/24/2021] [Revised: 11/09/2021] [Accepted: 11/23/2021] [Indexed: 05/18/2023]
Abstract
Residual antibiotics in food products originated from administration of the antibiotics to animals may be accumulated through food metabolism in the human body and endanger safety and health. Thus, developing a prompt and accurate way for detection of antibiotics is a crucial issue. The zero-dimensional fluorescent probes including metals based, carbon and graphene quantum dots (QDs), are highly sensitive materials to use for the detection of a wide range of antibiotics in natural products. These QDs demonstrate unique optical properties like tunable photoluminescence (PL) and excitation-wavelength dependent emission. This study investigates the trends related to carbon and metal based QDs preparation and modification, and their diverse detection application. We discuss the performance of QDs based sensors application in various detection systems such as photoluminescence, photoelectrochemical, chemiluminescence, electrochemiluminescence, colorimetric, as well as describing their working principles in several samples. The detecting mechanism of a QDs-based sensor is dependent on its properties and specific interactions with particular antibiotics. This review also tries to describe environmental application and future perspective of QDs for antibiotics detection.
Collapse
Affiliation(s)
| | - Mahmood Kazemzad
- Department of Energy, Materials and Energy Research Center, Tehran 14155-477, Iran.
| |
Collapse
|
36
|
Brett CMA. Electrochemical Impedance Spectroscopy in the Characterisation and Application of Modified Electrodes for Electrochemical Sensors and Biosensors. Molecules 2022; 27:1497. [PMID: 35268599 PMCID: PMC8911593 DOI: 10.3390/molecules27051497] [Citation(s) in RCA: 58] [Impact Index Per Article: 19.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 02/19/2022] [Accepted: 02/21/2022] [Indexed: 01/06/2023] Open
Abstract
Electrochemical impedance spectroscopy is finding increasing use in electrochemical sensors and biosensors, both in their characterisation, including during successive phases of sensor construction, and in application as a quantitative determination technique. Much of the published work continues to make little use of all the information that can be furnished by full physical modelling and analysis of the impedance spectra, and thus does not throw more than a superficial light on the processes occurring. Analysis is often restricted to estimating values of charge transfer resistances without interpretation and ignoring other electrical equivalent circuit components. In this article, the important basics of electrochemical impedance for electrochemical sensors and biosensors are presented, focussing on the necessary electrical circuit elements. This is followed by examples of its use in characterisation and in electroanalytical applications, at the same time demonstrating how fuller use can be made of the information obtained from complete modelling and analysis of the data in the spectra, the values of the circuit components and their physical meaning. The future outlook for electrochemical impedance in the sensing field is discussed.
Collapse
|
37
|
Ramanathan S, Gopinath SCB, Ismail ZH, Md Arshad MK, Poopalan P. Aptasensing nucleocapsid protein on nanodiamond assembled gold interdigitated electrodes for impedimetric SARS-CoV-2 infectious disease assessment. Biosens Bioelectron 2022; 197:113735. [PMID: 34736114 PMCID: PMC8550887 DOI: 10.1016/j.bios.2021.113735] [Citation(s) in RCA: 49] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/17/2021] [Accepted: 10/25/2021] [Indexed: 12/11/2022]
Abstract
In an aim of developing portable biosensor for SARS-CoV-2 pandemic, which facilitates the point-of-care aptasensing, a strategy using 10 μm gap-sized gold interdigitated electrode (AuIDE) is presented. The silane-modified AuIDE surface was deposited with ∼20 nm diamond and enhanced the detection of SARS-CoV-2 nucleocapsid protein (NCP). The characteristics of chemically modified diamond were evidenced by structural analyses, revealing the cubic crystalline nature at (220) and (111) planes as observed by XRD. XPS analysis denotes a strong interaction of carbon element, composed ∼95% as seen in EDS analysis. The C-C, CC, CO, CN functional groups were well-refuted from XPS spectra of carbon and oxygen elements in diamond. The interrelation between elements through FTIR analysis indicates major intrinsic bondings at 2687-2031 cm-1. The aptasensing was evaluated through electrochemical impedance spectroscopy measurements, using NCP spiked human serum. With a good selectivity the lower detection limit was evidenced as 0.389 fM, at a linear detection range from 1 fM to 100 pM. The stability, and reusability of the aptasensor were demonstrated, showing ∼30% and ∼33% loss of active state, respectively, after ∼11 days. The detection of NCP was evaluated by comparing anti-NCP aptamer and antibody as the bioprobes. The determination coefficients of R2 = 0.9759 and R2 = 0.9772 were obtained for aptamer- and antibody-based sensing, respectively. Moreover, the genuine interaction of NCP aptamer and protein was validated by enzyme linked apta-sorbent assay. The aptasensing strategy proposed with AuIDE/diamond enhanced sensing platform is highly recommended for early diagnosis of SARS-CoV-2 infection.
Collapse
Affiliation(s)
- Santheraleka Ramanathan
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), 01000, Kangar, Perlis, Malaysia
| | - Subash C B Gopinath
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), 01000, Kangar, Perlis, Malaysia; Faculty of Chemical Engineering Technology, Universiti Malaysia Perlis (UniMAP), 02600, Arau, Perlis, Malaysia.
| | - Zool Hilmi Ismail
- Centre for Artificial Intelligence and Robotics, Universiti Teknologi Malaysia, Jalan Sultan Yahya Petra, 54100, Kuala Lumpur, Malaysia.
| | - M K Md Arshad
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), 01000, Kangar, Perlis, Malaysia; Faculty of Electronic Engineering Technology, Universiti Malaysia Perlis (UniMAP), 02600, Arau, Pauh Putra, Perlis, Malaysia
| | - Prabakaran Poopalan
- Faculty of Electronic Engineering Technology, Universiti Malaysia Perlis (UniMAP), 02600, Arau, Pauh Putra, Perlis, Malaysia
| |
Collapse
|
38
|
Lasserre P, Balansethupathy B, Vezza VJ, Butterworth A, Macdonald A, Blair EO, McAteer L, Hannah S, Ward AC, Hoskisson PA, Longmuir A, Setford S, Farmer ECW, Murphy ME, Flynn H, Corrigan DK. SARS-CoV-2 Aptasensors Based on Electrochemical Impedance Spectroscopy and Low-Cost Gold Electrode Substrates. Anal Chem 2022; 94:2126-2133. [PMID: 35043638 PMCID: PMC8790822 DOI: 10.1021/acs.analchem.1c04456] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2021] [Accepted: 12/24/2021] [Indexed: 02/07/2023]
Abstract
SARS-CoV-2 diagnostic practices broadly involve either quantitative polymerase chain reaction (qPCR)-based nucleic amplification of viral sequences or antigen-based tests such as lateral flow assays (LFAs). Reverse transcriptase-qPCR can detect viral RNA and is the gold standard for sensitivity. However, the technique is time-consuming and requires expensive laboratory infrastructure and trained staff. LFAs are lower in cost and near real time, and because they are antigen-based, they have the potential to provide a more accurate indication of a disease state. However, LFAs are reported to have low real-world sensitivity and in most cases are only qualitative. Here, an antigen-based electrochemical aptamer sensor is presented, which has the potential to address some of these shortfalls. An aptamer, raised to the SARS-CoV-2 spike protein, was immobilized on a low-cost gold-coated polyester substrate adapted from the blood glucose testing industry. Clinically relevant detection levels for SARS-CoV-2 are achieved in a simple, label-free measurement format using sample incubation times as short as 15 min on nasopharyngeal swab samples. This assay can readily be optimized for mass manufacture and is compatible with a low-cost meter.
Collapse
Affiliation(s)
- Perrine Lasserre
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | | | - Vincent J. Vezza
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | - Adrian Butterworth
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | - Alexander Macdonald
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | - Ewen O. Blair
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | - Liam McAteer
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | - Stuart Hannah
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| | - Andrew C. Ward
- Department
of Civil and Environmental Engineering, University of Strathclyde, 75 Montrose Street, Glasgow G1 1XJ, U.K.
| | - Paul A. Hoskisson
- Strathclyde
Institute of Pharmacy and Biomedical Sciences (SIPBS), University of Strathclyde, 161 Cathedral Street, Glasgow G4 0RE, U.K.
| | - Alistair Longmuir
- LifeScan
Scotland Ltd, Beechwood Park North, Inverness IV2 3ED, U.K.
| | - Steven Setford
- LifeScan
Scotland Ltd, Beechwood Park North, Inverness IV2 3ED, U.K.
| | - Eoghan C. W. Farmer
- NHS GGC,
Department of Microbiology, Glasgow Royal
Infirmary, NEW Lister Building, Glasgow G31 2ER, United Kingdom
| | - Michael E. Murphy
- NHS GGC,
Department of Microbiology, Glasgow Royal
Infirmary, NEW Lister Building, Glasgow G31 2ER, United Kingdom
- School
of Medicine, Dentistry & Nursing, College of Medical Veterinary
& Life Sciences, University of Glasgow, Glasgow G12 8QQ, United Kingdom
| | - Harriet Flynn
- Aptamer
Group, Suite 2.78−2.91,
Bio Centre, Innovation Way, Heslington, York YO10 5NY, U.K.
- Department
of Pure and Applied Chemistry, University
of Strathclyde, 295 Cathedral
Street, Glasgow, G1 1XL, United Kingdom
| | - Damion K. Corrigan
- Department
of Biomedical Engineering, University of
Strathclyde, 106 Rottenrow East, Glasgow G4 0NW, U.K.
| |
Collapse
|
39
|
Tabish TA, Hayat H, Abbas A, Narayan RJ. Graphene Quantum Dots-Based Electrochemical Biosensing Platform for Early Detection of Acute Myocardial Infarction. BIOSENSORS 2022; 12:77. [PMID: 35200338 PMCID: PMC8869523 DOI: 10.3390/bios12020077] [Citation(s) in RCA: 28] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/30/2021] [Revised: 12/27/2021] [Accepted: 01/26/2022] [Indexed: 05/15/2023]
Abstract
Heart failure resulting from acute myocardial infarction (AMI) is an important global health problem. Treatments of heart failure and AMI have improved significantly over the past two decades; however, the available diagnostic tests only give limited insights into these heterogeneous conditions at a reversible stage and are not precise enough to evaluate the status of the tissue at high risk. Innovative diagnostic tools for more accurate, more reliable, and early diagnosis of AMI are urgently needed. A promising solution is the timely identification of prognostic biomarkers, which is crucial for patients with AMI, as myocardial dysfunction and infarction lead to more severe and irreversible changes in the cardiovascular system over time. The currently available biomarkers for AMI detection include cardiac troponin I (cTnI), cardiac troponin T (cTnT), myoglobin, lactate dehydrogenase, C-reactive protein, and creatine kinase and myoglobin. Most recently, electrochemical biosensing technologies coupled with graphene quantum dots (GQDs) have emerged as a promising platform for the identification of troponin and myoglobin. The results suggest that GQDs-integrated electrochemical biosensors can provide useful prognostic information about AMI at an early, reversible, and potentially curable stage. GQDs offer several advantages over other nanomaterials that are used for the electrochemical detection of AMI such as strong interactions between cTnI and GQDs, low biomarker consumption, and reusability of the electrode; graphene-modified electrodes demonstrate excellent electrochemical responses due to the conductive nature of graphene and other features of GQDs (e.g., high specific surface area, π-π interactions with the analyte, facile electron-transfer mechanisms, size-dependent optical features, interplay between bandgap and photoluminescence, electrochemical luminescence emission capability, biocompatibility, and ease of functionalization). Other advantages include the presence of functional groups such as hydroxyl, carboxyl, carbonyl, and epoxide groups, which enhance the solubility and dispersibility of GQDs in a wide variety of solvents and biological media. In this perspective article, we consider the emerging knowledge regarding the early detection of AMI using GQDs-based electrochemical sensors and address the potential role of this sensing technology which might lead to more efficient care of patients with AMI.
Collapse
Affiliation(s)
- Tanveer A. Tabish
- Department of Materials and London Centre for Nanotechnology, Imperial College London, London SW7 2AZ, UK;
| | - Hasan Hayat
- College of Engineering, Swansea University, Wales SA1 8EN, UK;
| | - Aumber Abbas
- School of Engineering, Newcastle University, Newcastle upon Tyne NE1 7RU, UK;
| | - Roger J. Narayan
- Joint Department of Biomedical Engineering, North Carolina and North Carolina State University, Raleigh, NC 27695-7907, USA
| |
Collapse
|
40
|
Deenin W, Yakoh A, Kreangkaiwal C, Chailapakul O, Patarakul K, Chaiyo S. Integrated Lateral Flow Electrochemical Strip for Leptospirosis Diagnosis. Anal Chem 2022; 94:2554-2560. [PMID: 35089007 DOI: 10.1021/acs.analchem.1c04440] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
LipL32 is an outer membrane protein present only on pathogenic Leptospira species, which is the causative agent of leptospirosis. Leptospirosis symptoms are often misdiagnosed with other febrile illnesses as the clinical manifestations are non-specific. Therefore, an accurate diagnostic tool for leptospirosis is indeed critical for proper and prompt treatment. Typical diagnosis via serological assays is generally performed to assess the antibodies produced against Leptospira. However, their delayed antibody response and complicated procedure undoubtedly limit the practical utilization especially in a primary care setting. Here, we demonstrate for the first time an early-stage detection of LipL32 by an integrated lateral-flow immunoassay with an electrochemical readout (eLFIA). A ferrocene trace tag was monitored via differential pulse voltammetry operated on a smartphone-based device, thus allowing for on-field testing. A superior performance in terms of the lowest detectable limit of detection of 8.53 pg/mL and broad linear dynamic range (5 orders of magnitude) among other sensors available thus far was established. Additionally, the developed test strip provided a straightforward yet sensitive approach for diagnosis of leptospirosis using the collected human sera from patients, in which the results were comparable to the real-time polymerase chain reaction technique.
Collapse
Affiliation(s)
- Wanwisa Deenin
- Program in Biotechnology, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand.,Institute of Biotechnology and Genetic Engineering, Chulalongkorn University, Bangkok 10330, Thailand
| | - Abdulhadee Yakoh
- Institute of Biotechnology and Genetic Engineering, Chulalongkorn University, Bangkok 10330, Thailand.,Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand
| | - Chahya Kreangkaiwal
- Department of Microbiology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand
| | - Orawon Chailapakul
- Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand
| | - Kanitha Patarakul
- Department of Microbiology, Faculty of Medicine, Chulalongkorn University, Bangkok 10330, Thailand
| | - Sudkate Chaiyo
- Institute of Biotechnology and Genetic Engineering, Chulalongkorn University, Bangkok 10330, Thailand.,Electrochemistry and Optical Spectroscopy Center of Excellence (EOSCE), Department of Chemistry, Faculty of Science, Chulalongkorn University, Bangkok 10330, Thailand.,Food Risk Hub, Research Unit of Chulalongkorn University, Bangkok 10330, Thailand
| |
Collapse
|
41
|
Sun Q, Liu X, Tang H, Qian Y, Gu H, He H. A Sandwich‐type Electrochemical Immunosensor for the Sensitive Determination of
Salmonella
Typhimurium in Food. ELECTROANAL 2022. [DOI: 10.1002/elan.202100561] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Affiliation(s)
- Qiaoling Sun
- School of Public Health Nantong University 226019 Nantong P. R. China
| | - Xiaojun Liu
- Jiangyin Center for Disease Control and Prevention 214431 Wuxi P. R. China
| | - Haowen Tang
- School of Public Health Nantong University 226019 Nantong P. R. China
| | - Yuying Qian
- School of Public Health Nantong University 226019 Nantong P. R. China
| | - Haiying Gu
- School of Public Health Nantong University 226019 Nantong P. R. China
| | - Hong He
- Affiliated Hospital Nantong University 226001 Nantong P. R. China
| |
Collapse
|
42
|
Ge R, Zhu Y, Wang H, Gu S. Methods and Application of Absolute Configuration Assignment for Chiral Compounds. CHINESE J ORG CHEM 2022. [DOI: 10.6023/cjoc202108047] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
43
|
Flauzino JMR, Nguyen EP, Yang Q, Rosati G, Panáček D, Brito-Madurro AG, Madurro JM, Bakandritsos A, Otyepka M, Merkoçi A. Label-free and reagentless electrochemical genosensor based on graphene acid for meat adulteration detection. Biosens Bioelectron 2022; 195:113628. [PMID: 34543917 DOI: 10.1016/j.bios.2021.113628] [Citation(s) in RCA: 27] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Revised: 08/31/2021] [Accepted: 09/09/2021] [Indexed: 12/25/2022]
Abstract
With the increased demand for beef in emerging markets, the development of quality-control diagnostics that are fast, cheap and easy to handle is essential. Especially where beef must be free from pork residues, due to religious, cultural or allergic reasons, the availability of such diagnostic tools is crucial. In this work, we report a label-free impedimetric genosensor for the sensitive detection of pork residues in meat, by leveraging the biosensing capabilities of graphene acid - a densely and selectively functionalized graphene derivative. A single stranded DNA probe, specific for the pork mitochondrial genome, was immobilized onto carbon screen-printed electrodes modified with graphene acid. It was demonstrated that graphene acid improved the charge transport properties of the electrode, following a simple and rapid electrode modification and detection protocol. Using non-faradaic electrochemical impedance spectroscopy, which does not require any electrochemical indicators or redox pairs, the detection of pork residues in beef was achieved in less than 45 min (including sample preparation), with a limit of detection of 9% w/w pork content in beef samples. Importantly, the sample did not need to be purified or amplified, and the biosensor retained its performance properties unchanged for at least 4 weeks. This set of features places the present pork DNA sensor among the most attractive for further development and commercialization. Furthermore, it paves the way for the development of sensitive and selective point-of-need sensing devices for label-free, fast, simple and reliable monitoring of meat purity.
Collapse
Affiliation(s)
- José M R Flauzino
- Institute of Biotechnology, Federal University of Uberlândia, 38405-319, Uberlândia, MG, Brazil; Catalan Institute of Nanoscience and Nanotechnology, Autonomous University of Barcelona, 08193, Bellaterra, Barcelona, Spain
| | - Emily P Nguyen
- Catalan Institute of Nanoscience and Nanotechnology, Autonomous University of Barcelona, 08193, Bellaterra, Barcelona, Spain
| | - Qiuyue Yang
- Catalan Institute of Nanoscience and Nanotechnology, Autonomous University of Barcelona, 08193, Bellaterra, Barcelona, Spain
| | - Giulio Rosati
- Catalan Institute of Nanoscience and Nanotechnology, Autonomous University of Barcelona, 08193, Bellaterra, Barcelona, Spain
| | - David Panáček
- Catalan Institute of Nanoscience and Nanotechnology, Autonomous University of Barcelona, 08193, Bellaterra, Barcelona, Spain; Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute (CATRIN), Palacký University Olomouc, Šlechtitelů 241/27, 783 71, Olomouc, Czech Republic; Department of Physical Chemistry, Faculty of Science, Palacký University Olomouc, 17. listopadu 1192/12, 771 46, Olomouc, Czech Republic
| | - Ana G Brito-Madurro
- Institute of Biotechnology, Federal University of Uberlândia, 38405-319, Uberlândia, MG, Brazil
| | - João M Madurro
- Institute of Biotechnology, Federal University of Uberlândia, 38405-319, Uberlândia, MG, Brazil; Institute of Chemistry, Federal University of Uberlândia, 38400-902, Uberlândia, MG, Brazil
| | - Aristides Bakandritsos
- Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute (CATRIN), Palacký University Olomouc, Šlechtitelů 241/27, 783 71, Olomouc, Czech Republic; Nanotechnology Centre, Centre of Energy and Environmental Technologies, VŠB-Technical University of Ostrava, 17. listopadu 2172/15, 708 00, Ostrava-Poruba, Czech Republic
| | - Michal Otyepka
- Regional Centre of Advanced Technologies and Materials, Czech Advanced Technology and Research Institute (CATRIN), Palacký University Olomouc, Šlechtitelů 241/27, 783 71, Olomouc, Czech Republic; IT4Innovations, VŠB-Technical University of Ostrava, 17. listopadu 2172/15, 708 00, Ostrava-Poruba, Czech Republic
| | - Arben Merkoçi
- Catalan Institute of Nanoscience and Nanotechnology, Autonomous University of Barcelona, 08193, Bellaterra, Barcelona, Spain.
| |
Collapse
|
44
|
Cao L, Zhang W, Lu S, Guo C, Wang P, Zhang D, Ma W. A Label-Free Electrochemical Immunosensor for CEA Detection on a Novel Signal Amplification Platform of Cu 2S/Pd/CuO Nanocomposites. Front Bioeng Biotechnol 2021; 9:767717. [PMID: 34957069 PMCID: PMC8702859 DOI: 10.3389/fbioe.2021.767717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/31/2021] [Accepted: 11/15/2021] [Indexed: 11/24/2022] Open
Abstract
Carcinoembryonic antigen (CEA) is regarded as one of the crucial tumor markers for colorectal cancer. In this study, we developed the snowflake Cu2S/Pd/CuO nanocomposite to construct an original label-free electrochemical immunosensor for the ultrasensitive detection of CEA levels. The nanocomposite of cuprous sulfide (Cu2S) with Pd nanoparticles (Pd NPs) was synthesized through an in situ formation of Pd NPs on the Cu2S. Cuprous sulfide (Cu2S) and CuO can not only be used as a carrier to increase the reaction area but also catalyze the substrate to generate current signal. Palladium nanoparticles (Pd NPs) have excellent catalytic properties and good biocompatibility, as well as the ability of excellent electron transfer. The immunosensor was designed using 5 mmol/L H2O2 as the active substrate by optimizing the conditions with a detection range from 100 fg/ml to 100 ng/ml and a minimum detection limit of 33.11 fg/ml. The human serum was detected by electrochemical immunoassay, and the results were consistent with those of the commercial electrochemical immunosensor. Therefore, the electrochemical immunosensor can be used for the detection of human serum samples and have potential value for clinical application.
Collapse
Affiliation(s)
- Linlin Cao
- Department of Laboratory Medicine, Shandong Provincial Qianfoshan Hospital, Shandong University, Jinan, China.,Department of Clinical Laboratory, Zibo Central Hospital, Shandong University, Zibo, China
| | - Wen Zhang
- Department of Clinical Laboratory, Zibo Central Hospital, Shandong University, Zibo, China
| | - Sumei Lu
- Department of Laboratory Medicine, Shandong Provincial Qianfoshan Hospital, Shandong University, Jinan, China.,Department of Laboratory Medicine, The First Affiliated Hospital of Shandong First Medical University, Jinan, China
| | - Chengjie Guo
- Department of Clinical Laboratory, Zibo Central Hospital, Shandong University, Zibo, China
| | - Peijun Wang
- Department of Laboratory Medicine, Shandong Provincial Qianfoshan Hospital, Shandong University, Jinan, China
| | - Dantong Zhang
- Department of Laboratory Medicine, The First Affiliated Hospital of Shandong First Medical University, Jinan, China
| | - Wanshan Ma
- Department of Laboratory Medicine, Shandong Provincial Qianfoshan Hospital, Shandong University, Jinan, China.,Department of Laboratory Medicine, The First Affiliated Hospital of Shandong First Medical University, Jinan, China
| |
Collapse
|
45
|
Khanwalker M, Fujita R, Lee J, Wilson E, Ito K, Asano R, Ikebukuro K, LaBelle J, Sode K. Development of a POCT type insulin sensor employing anti-insulin single chain variable fragment based on faradaic electrochemical impedance spectroscopy under single frequency measurement. Biosens Bioelectron 2021; 200:113901. [PMID: 34968857 DOI: 10.1016/j.bios.2021.113901] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 12/15/2021] [Accepted: 12/16/2021] [Indexed: 11/24/2022]
Abstract
To improve glycemic control managed through insulin administration, recent studies have focused on developing hand-held point-of-care testing (POCT) electrochemical biosensors for insulin measurement. Amongst them, anti-insulin IgG-based sensors show promise in detecting insulin with high specificity and sensitivity. However, fabrication of electrochemical sensors with IgG antibodies can prove challenging because of their larger molecular size. To overcome these limitations, this study focuses on utilizing the anti-insulin single chain variable fragment (scFv) as a biosensing molecule with single-frequency faradaic electrochemical impedance spectroscopy (EIS). By comparing two different immobilization methods, covalent conjugation via succinimidyl ester and non-covalent poly-histidine chelation, we demonstrated effective modification of the electrode surface with anti-insulin scFv, while retaining its specific recognition toward insulin. Sensor performance was confirmed via the concentration-dependent faradaic electrochemical impedance change using potassium ferricyanide as a redox probe. The optimal frequency for measurement was determined to be the peak slope of the calculated impedance correlation with respect to frequency. Based on the identified optimized frequency, we performed single-frequency measurement of insulin within a concentration range of 10 pM-100 nM. This study can aid in developing a future point-of-care sensor which rapidly and sensitively measures insulin across a dynamic range of physiological concentrations, with label-free detection.
Collapse
Affiliation(s)
- Mukund Khanwalker
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC27599, USA
| | - Rinko Fujita
- Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo, 184-8588, Japan
| | - Jinhee Lee
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC27599, USA
| | - Ellie Wilson
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC27599, USA
| | - Kohei Ito
- Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo, 184-8588, Japan
| | - Ryutaro Asano
- Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo, 184-8588, Japan
| | - Kazunori Ikebukuro
- Department of Biotechnology and Life Science, Graduate School of Engineering, Tokyo University of Agriculture and Technology, 2-24-16 Naka-cho, Koganei, Tokyo, 184-8588, Japan
| | - Jeffrey LaBelle
- Department of Bioengineering, College of Engineering Science and Technology, Grand Canyon University, Phoenix, AZ, AZ85017, USA
| | - Koji Sode
- Joint Department of Biomedical Engineering, The University of North Carolina at Chapel Hill and North Carolina State University, Chapel Hill, NC27599, USA.
| |
Collapse
|
46
|
|
47
|
Anthi J, Kolivoška V, Holubová B, Vaisocherová-Lísalová H. Probing polymer brushes with electrochemical impedance spectroscopy: a mini review. Biomater Sci 2021; 9:7379-7391. [PMID: 34693954 DOI: 10.1039/d1bm01330k] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
Abstract
Polymer brushes are frequently used as surface-tethered antifouling layers in biosensors to improve sensor surface-analyte recognition in the presence of abundant non-target molecules in complex biological samples by suppressing nonspecific interactions. However, because brushes are complex systems highly responsive to changes in their surrounding environment, studying their properties remains a challenge. Electrochemical impedance spectroscopy (EIS) is an emerging method in this context. In this mini review, we aim to elucidate the potential of EIS for investigating the physicochemical properties and structural aspects of polymer brushes. The application of EIS in brush-based biosensors is also discussed. Most common principles employed in these biosensors are presented, as well as interpretation of EIS data obtained in such setups. Overall, we demonstrate that the EIS-polymer brush pairing has a considerable potential for providing new insights into brush functionalities and designing highly sensitive and specific biosensors.
Collapse
Affiliation(s)
- Judita Anthi
- Institute of Physics of the CAS, Na Slovance 2, 182 21 Prague, Czech Republic. .,Department of Biochemistry and Microbiology, University of Chemistry and Technology Prague, Technická 3, 16628 Prague, Czech Republic
| | - Viliam Kolivoška
- J. Heyrovský Institute of Physical Chemistry of the Czech Academy of Sciences, Dolejškova 3, 182 23 Prague, Czech Republic.
| | - Barbora Holubová
- Department of Biochemistry and Microbiology, University of Chemistry and Technology Prague, Technická 3, 16628 Prague, Czech Republic
| | | |
Collapse
|
48
|
Chellachamy Anbalagan A, Sawant SN. Carboxylic acid-tethered polyaniline as a generic immobilization matrix for electrochemical bioassays. Mikrochim Acta 2021; 188:403. [PMID: 34731317 DOI: 10.1007/s00604-021-05059-7] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/19/2021] [Accepted: 10/11/2021] [Indexed: 10/19/2022]
Abstract
Polyaniline (PANI) was functionalized by thiol-ene click chemistry to obtain carboxylic acid-tethered polyaniline (PCOOH). The versatility of PCOOH as an immobilization matrix was demonstrated by constructing four different biosensors for detection of metabolites and cancer biomarker. Immobilization efficiency of PCOOH was investigated by surface plasmon resonance and fluorescence microscopic analysis which revealed dense immobilization of biomolecules on PCOOH as compared to conventional PANI. A sandwich electrochemical biosensor was constructed using PCOOH for detection of liver cancer biomarker, α-fetoprotein (AFP). The sensor displayed sensitivity of 15.24 µA (ng mL-1)-1 cm-2, with good specificity, reproducibility (RSD 3.4%), wide linear range (0.25-40 ng mL-1) at - 0.1 V (vs. Ag/AgCl), and a low detection limit of 2 pg mL-1. The sensor was validated by estimating AFP in human blood serum samples where the AFP concentrations obtained are consistent with the values estimated using ELISA. Furthermore, utilization of PCOOH for construction of enzymatic biosensor was demonstrated by covalent immobilization of glucose oxidase, uricase, and horseradish peroxidase (HRP) for detection of glucose, uric acid, and H2O2, respectively. The biosensors displayed reasonable sensitivity (50, 148, 127 µA mM-1 cm-2), and linear ranges (0.1-5, 0.1-6, 0.1-7 mM) with a detection limit of 10, 1, and 8 µM for glucose, uric acid, and H2O2, respectively. The present study demonstrates the capability of PCOOH to support and enable oxidation of H2O2 generated by oxidase enzymes as well as HRP enzyme catalyzed reduction of H2O2. Thus, PCOOH offers a great promise as an immobilization matrix for development of high-performance biosensors to quantify a variety of other disease biomarkers. Carboxylic acid-tethered polyaniline synthesized by thiol-ene click chemistry was used as matrix to construct four different electrochemical biosensors for detection of cancer biomarker α-fetoprotein, glucose, uric acid, and H2O2.
Collapse
Affiliation(s)
| | - Shilpa N Sawant
- Chemistry Division, Bhabha Atomic Research Centre, Trombay, Mumbai, 400085, India. .,Homi Bhabha National Institute, Anushaktinagar, Mumbai, 400094, India.
| |
Collapse
|
49
|
Diaz-Armas GG, Cervantes-Gonzalez AP, Martinez-Duarte R, Perez-Gonzalez VH. Electrically driven microfluidic platforms for exosome manipulation and characterization. Electrophoresis 2021; 43:327-339. [PMID: 34717000 DOI: 10.1002/elps.202100202] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/29/2021] [Revised: 10/06/2021] [Accepted: 10/25/2021] [Indexed: 01/15/2023]
Abstract
Exosomes are small extracellular vesicles that can be obtained from several body fluids such as blood and urine. Since these vesicles can carry biomarkers and other cargo, they have application in healthcare diagnostics and therapeutics, such as liquid biopsies and drug delivery. Yet, their identification and separation from a sample remain challenging due to their high degree of heterogeneity and their co-existence with other bioparticles. In this contribution, we review the state-of-the-art on electrical techniques and methods to displace, selectively trap/isolate, and detect/characterize exosomes in microfluidic devices. Although there are many reviews focused on exosome separation using benchtop equipment, such as ultracentrifugation, there are limited reviews focusing on the use of electrical phenomena in microfluidic devices for exosome manipulation and detection. Here, we highlight contributions published during the past decade and present perspectives for this research field for the near future, outlining challenges to address in years to come.
Collapse
Affiliation(s)
- Gladys G Diaz-Armas
- Tecnologico de Monterrey, School of Engineering and Sciences, Monterrey, Mexico
| | | | - Rodrigo Martinez-Duarte
- Multiscale Manufacturing Laboratory, Department of Mechanical Engineering, Clemson University, Clemson, South Carolina, USA
| | | |
Collapse
|
50
|
Li J, Wang Y, Li R, Lu B, Yuan Y, Gao H, Song S, Zhou S, Zang J. Amorphous Carbon Film with Self‐modified Carbon Nanoparticles Synthesized by Low Temperature Carbonization of Phenolic Resin for Simultaneous Sensing of Dopamine and Uric Acid. ELECTROANAL 2021. [DOI: 10.1002/elan.202100182] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Jilong Li
- State Key Laboratory of Metastable Materials Science and Technology, School of Materials Science and Engineering Yanshan University Qinhuangdao 066004 PR China
| | - Yanhui Wang
- State Key Laboratory of Metastable Materials Science and Technology, School of Materials Science and Engineering Yanshan University Qinhuangdao 066004 PR China
| | - Rushuo Li
- Beijing Advanced Innovation Center for Materials Genome Engineering, Beijing Key Laboratory of Function Materials for Molecule & Structure Construction, School of Materials Science and Engineering University of Science and Technology Beijing Beijing 100083 PR China
| | - Bowen Lu
- State Key Laboratory of Metastable Materials Science and Technology, School of Materials Science and Engineering Yanshan University Qinhuangdao 066004 PR China
| | - Yungang Yuan
- State Key Laboratory of Metastable Materials Science and Technology, School of Materials Science and Engineering Yanshan University Qinhuangdao 066004 PR China
| | - Hongwei Gao
- State Key Laboratory of Metastable Materials Science and Technology, School of Materials Science and Engineering Yanshan University Qinhuangdao 066004 PR China
| | - Shiwei Song
- State Key Laboratory of Metastable Materials Science and Technology, School of Materials Science and Engineering Yanshan University Qinhuangdao 066004 PR China
| | - Shuyu Zhou
- State Key Laboratory of Metastable Materials Science and Technology, School of Materials Science and Engineering Yanshan University Qinhuangdao 066004 PR China
| | - Jianbing Zang
- State Key Laboratory of Metastable Materials Science and Technology, School of Materials Science and Engineering Yanshan University Qinhuangdao 066004 PR China
| |
Collapse
|