1
|
Hu YJ, Yu YE, Cooper HJ, Shah RP, Geller JA, Lu XL, Shane E, Bathon J, Lane NE, Guo XE. Mechanical and structural properties of articular cartilage and subchondral bone in human osteoarthritic knees. J Bone Miner Res 2024; 39:1120-1131. [PMID: 38887013 DOI: 10.1093/jbmr/zjae094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/19/2023] [Revised: 05/20/2024] [Accepted: 06/13/2024] [Indexed: 06/20/2024]
Abstract
Knee osteoarthritis (OA), characterized by multiple joint tissue degenerations, remains a significant clinical challenge. Recent evidence suggests that crosstalk within the osteochondral unit may drive OA progression. Although structural-biomechanical properties of bone and cartilage have been studied, potential interaction within the osteochondral unit in the context of OA has yet to be investigated. We performed comprehensive structural and biomechanical quantification of the cartilage, subchondral bone plate (SBP), and subchondral trabecular bone (STB) using 101 osteochondral cores collected from tibial plateaus of 12 control human cadavers (CT, 5 male/7 female) and 19 patients undergoing total knee replacement (OA, 6 male/13 female). For each sample, we quantified SBP microstructure, plate-and-rod morphological properties of the STB using individual trabecula segmentation, and morphological and compositional properties of the articular cartilage. We also performed indentation testing on each compartment of the osteochondral unit to extract the respective structural-mechanical properties. Cartilage thickness was lower in moderate and severe OA regions, while Osteoarthritis Research Society International score was higher only in severe OA regions. GAG content did not change in any OA region. Aggregate and shear moduli were lower only in severe OA regions, while permeability was lower only in moderate OA regions. In the SBP, thickness and tissue mineral density were higher in moderate and severe OA regions. Tissue modulus of STB was lower in moderate OA regions despite a thicker and more mineralized SBP; this deterioration was not observed in severe OA regions. Regression analysis revealed strong correlations between cartilage and STB properties in CT; these correlations were also found in moderate OA regions but were not observed in severe OA regions. In summary, our findings comprehensively characterize the human OA osteochondral unit. Importantly, uncoupling cartilage and subchondral bone structural-mechanical properties may be a hallmark of OA.
Collapse
Affiliation(s)
- Yizhong Jenny Hu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY 10027, United States
| | - Y Eric Yu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY 10027, United States
| | - Herbert J Cooper
- Department of Orthopaedic Surgery, Columbia University Medical Center, New York, NY 10032, United States
| | - Roshan P Shah
- Department of Orthopaedic Surgery, Columbia University Medical Center, New York, NY 10032, United States
| | - Jeffrey A Geller
- Department of Orthopaedic Surgery, Columbia University Medical Center, New York, NY 10032, United States
| | - X Lucas Lu
- Department of Mechanical Engineering, University of Delaware, Newark, DE 19716, United States
| | - Elizabeth Shane
- Division of Endocrinology, Department of Medicine, Columbia University Irving Medical Center, Vagelos College of Physicians and Surgeons, New York, NY 10032, United States
| | - Joan Bathon
- Division of Rheumatology, Department of Medicine, New York-Presbyterian/Columbia University Irving Medical Center, New York, NY 10032, United States
| | - Nancy E Lane
- Division of Rheumatology, Department of Medicine, University of California Davis, Davis, CA 95817, United States
| | - X Edward Guo
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY 10027, United States
| |
Collapse
|
2
|
Koria L, Farndon M, Jones E, Mengoni M, Brockett C. Changes in subchondral bone morphology with osteoarthritis in the ankle. PLoS One 2024; 19:e0290914. [PMID: 38889162 PMCID: PMC11185451 DOI: 10.1371/journal.pone.0290914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Accepted: 02/27/2024] [Indexed: 06/20/2024] Open
Abstract
Significant alterations to subchondral trabecular bone microarchitecture are observed in late-stage osteoarthritis (OA). However, detailed investigation of these changes to bone in the ankle are under-reported. This study aimed to fully characterise the trabecular morphology in OA ankle bone specimens compared to non-diseased (ND) controls using both standard and individual-trabecular segmentation-based (ITS) analyses. Ten ND tibial bone specimens were extracted from three cadaveric ankles, as well as five OA bone specimens from patients undergoing total ankle arthroplasty surgery. Each specimen was scanned using microcomputed tomography from which a 4 mm cuboidal volume was extracted for analysis. Morphological parameters for the subchondral trabecular bone were measured using BoneJ (NIH ImageJ) and 3D ITS for whole volumes and at each depth level in 1 mm increments. The results show an overall increase in bone volume fraction (p<0.01) and trabecular thickness (p<0.001) with OA, with a decrease in anisotropy (p<0.05). ITS analysis showed OA bone was composed of more rod-like trabeculae and plate-like trabeculae compared to ND bone. Numerous properties were depth dependent, but the results demonstrated that towards the subchondral bone plate, both rod- and plate-like trabeculae were thicker, rods were longer and plates had increased surface area. Overall, this study has verified key microstructural alterations to ankle subchondral bone that are found in other OA lower-limb joints. Depth-based analysis has highlighted differences of interest for further evaluation into the remodelling mechanisms that occur with OA, which is critical to understanding the role of subchondral bone microarchitecture in the progression of the disease.
Collapse
Affiliation(s)
- Lekha Koria
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
| | - Mark Farndon
- Harrogate and District NHS Foundation Trust, Harrogate, United Kingdom
| | - Elena Jones
- Leeds Institute of Rheumatic and Musculoskeletal Medicine, School of Medicine, University of Leeds, Leeds, United Kingdom
| | - Marlène Mengoni
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
| | - Claire Brockett
- Institute of Medical and Biological Engineering, School of Mechanical Engineering, University of Leeds, Leeds, United Kingdom
| |
Collapse
|
3
|
Zhou Y, Isaksson P, Persson C. An improved trabecular bone model based on Voronoi tessellation. J Mech Behav Biomed Mater 2023; 148:106172. [PMID: 37852087 DOI: 10.1016/j.jmbbm.2023.106172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 09/17/2023] [Accepted: 10/09/2023] [Indexed: 10/20/2023]
Abstract
BACKGROUND AND OBJECTIVE Accurate numerical and physical models of trabecular bone, correctly representing its complexity and variability, could be highly advantageous in the development of e.g. new bone-anchored implants due to the limited availability of real bone. Several Voronoi tessellation-based porous models have been reported in the literature, attempting to mimic the trabecular bone. However, these models have been limited to lattice rod-like structures, which are only structurally representative of very high-porosity trabecular bone. The objective of this study was to provide an improved model, more representative of trabecular bone of different porosity. METHODS Boolean operations were utilized to merge scaled Voronoi cells, thereby introducing different structural patterns, controlling porosity and to some extent anisotropy. The mechanical properties of the structures were evaluated using analytical estimations, numerical simulations, and experimental compression tests of 3D-printed versions of the structures. The capacity of the developed models to represent trabecular bone was assessed by comparing some key geometric features with trabecular bone characterized in previous studies. RESULTS The models gave the possibility to provide pore interconnectivity at relatively low porosities as well as both plate- and rod-like structures. The mechanical properties of the generated models were predictable with numerical simulations as well as an analytical approach. The permeability was found to be better than Sawbones at the same porosity. The models also showed the capability of matching e.g. some vertebral structures for key geometric features. CONCLUSIONS An improved numerical model for mimicking trabecular bone structures was successfully developed using Voronoi tessellation and Boolean operations. This is expected to benefit both computational and experimental studies by providing a more diverse and representative structure of trabecular bone.
Collapse
Affiliation(s)
- Yijun Zhou
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Box 35, Uppsala, 75121, Sweden.
| | - Per Isaksson
- Division of Applied Mechanics, Department of Materials Science and Engineering, Uppsala University, Box 35, Uppsala, 75121, Sweden.
| | - Cecilia Persson
- Division of Biomedical Engineering, Department of Materials Science and Engineering, Uppsala University, Box 35, Uppsala, 75121, Sweden.
| |
Collapse
|
4
|
Bredella MA, Fazeli PK, Bourassa J, Rosen CJ, Bouxsein ML, Klibanski A, Miller KK. The effect of short-term high-caloric feeding and fasting on bone microarchitecture. Bone 2022; 154:116214. [PMID: 34571202 PMCID: PMC8671292 DOI: 10.1016/j.bone.2021.116214] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/02/2021] [Revised: 09/15/2021] [Accepted: 09/20/2021] [Indexed: 01/03/2023]
Abstract
BACKGROUND States of chronic overnutrition and undernutrition are both associated with impaired bone health and increased fracture risk but there are no data on bone microarchitecture following short-term controlled nutritional challenges. OBJECTIVE The purpose of our study was to evaluate the impact of short-term high-caloric feeding and fasting on bone microarchitecture. We hypothesized that both high-caloric feeding and fasting would have negative effects on microarchitecture. MATERIALS AND METHODS We recruited 23 adult healthy subjects (13 males, 10 females, mean age 33.2 ± 1.4 years, mean BMI 26.0 ± 1.5 kg/m2). Subjects underwent an in-patient 10-day high-caloric visit (caloric intake with goal to achieve 7% weight gain), after which they went home to resume a normal diet for 13-18 days (stabilization period), and were then readmitted for a 10-day in-patient fasting stay (no caloric intake). All subjects underwent HRpQCT (XtremeCT, Scanco Medical AG, Brüttisellen, Switzerland) of the distal tibia and distal radius after each visit to assess volumetric bone mineral density (vBMD), trabecular and cortical microarchitecture, and strength estimates. The Wilcoxon signed rank test was used to perform within group comparisons. RESULTS During the high-caloric period, there was a mean increase in weight by 6.3 + 1.7% (p < 0.0001). There were no significant changes in bone parameters in the distal tibia or distal radius (p > 0.05). During the stabilization period there was a significant reduction in weight by -2.7 + 1.9% (p < 0.0001) but no change in bone parameters (p > 0.05). During the fasting period there was a further reduction in weight by -8.8 + 1.2% (p < 0.0001). In the distal tibia, there was a significant increase in total and cortical vBMD, trabecular and cortical parameters as well as strength estimates (p < 0.05). In the distal radius there was an increase in total and trabecular vBMD (p < 0.05), while there were no changes in other microarchitecture parameters or strengths estimates. CONCLUSION Short-term fasting after high-caloric feeding improves vBMD, bone microarchitecture and strength estimates of the distal tibia, while short-term high-caloric feeding does not change vBMD or microarchitecture. These results suggest that short-term fasting after high-caloric feeding in healthy individuals improves bone health and that these changes can be detected using HRpQCT in-vivo.
Collapse
Affiliation(s)
- Miriam A Bredella
- Division of Musculoskeletal Imaging and Intervention, Department of Radiology, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, United States of America.
| | - Pouneh K Fazeli
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, United States of America
| | - Jenna Bourassa
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, United States of America
| | - Clifford J Rosen
- Maine Medical Center Research Institute, Scarborough, ME, United States of America
| | - Mary L Bouxsein
- Department of Orthopedic Surgery, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, United States of America
| | - Anne Klibanski
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, United States of America
| | - Karen K Miller
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, Boston, MA 02114, United States of America
| |
Collapse
|
5
|
Hu YJ, Chines A, Shi Y, Seeman E, Guo XE. The effect of denosumab and alendronate on trabecular plate and rod microstructure at the distal tibia and radius: A post-hoc HR-pQCT study. Bone 2022; 154:116187. [PMID: 34530172 DOI: 10.1016/j.bone.2021.116187] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2021] [Revised: 09/02/2021] [Accepted: 09/09/2021] [Indexed: 01/23/2023]
Abstract
BACKGROUND Age-related trabecular microstructural deterioration and conversion from plate-like trabeculae to rod-like trabeculae occur because of unbalanced rapid remodeling. As denosumab achieves greater remodeling suppression and lower cortical porosity than alendronate, we hypothesized that denosumab might also preserve trabecular plate microstructure, bone stiffness and strength more effectively than alendronate. METHODS In this post hoc analysis of a phase 2 study, postmenopausal women randomized to placebo (P, n = 74), denosumab (D, n = 72), or alendronate (A, n = 68). HR-pQCT scans of the distal radius and tibia were performed at baseline and Month-12 (M12). Trabecular compartment was subjected to Individual Trabecula Segmentation while finite element analysis was performed to estimate stiffness and strength. Percent change from baseline at M12 of each parameter was compared between patient groups. RESULTS At the distal tibia, in the placebo group, plate surface area (pTb.S, -1.3%) decreased while rod bone volume fraction (rBV/TV, +4.5%) and number (rTb.N, +2.1%) increased. These changes were prevented by denosumab but persisted despite alendronate therapy (pTb.S: -1.7%; rBV/TV: +6.9%; rTb.N: +3.0%). Both treatments improved whole bone stiffness (D: +3.1%; A: +1.8%) and failure load (D: +3.0%; A: +2.2%); improvements using denosumab was significant compared to placebo (stiffness: p = 0.004; failure load: p = 0.003). At the distal radius, denosumab increased total trabecular bone volume fraction (BV/TV, +3.4%) and whole bone failure load (+4.0%), significantly different from placebo (BV/TV: p = 0.044; failure load: p = 0.046). Significantly different effects of either drug on plate and rod microstructure were not detected. CONCLUSIONS Denosumab preserved trabecular plate microstructure. Alendronate did not. However, estimated strength did not differ between denosumab and alendronate treated groups.
Collapse
Affiliation(s)
- Yizhong Jenny Hu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | | | | | - Ego Seeman
- Departments of Endocrinology and Medicine, Austin Health, University of Melbourne, Melbourne, Australia; Mary MacKillop Institute of Healthy Aging, Australian Catholic University, Melbourne, Australia
| | - X Edward Guo
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| |
Collapse
|
6
|
Robinson ST, Shyu PT, Guo XE. Mechanical loading and parathyroid hormone effects and synergism in bone vary by site and modeling/remodeling regime. Bone 2021; 153:116171. [PMID: 34492358 PMCID: PMC8499476 DOI: 10.1016/j.bone.2021.116171] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Revised: 08/01/2021] [Accepted: 08/31/2021] [Indexed: 01/22/2023]
Abstract
Intermittent injections of parathyroid hormone (PTH) and mechanical loading are both known to effect a net increase in bone mass. Fundamentally, bone metabolism can be divided into modeling (uncoupled formation or resorption) and remodeling (subsequent formation biologically coupled to resorption in space and time). Methods to delineate the bone response between these regimes are scant but have garnered recent attention and acceptance, and will be critical tools to properly assess short- and long-term efficacy of osteoporosis treatments. To this end, we employ a time-lapse micro-computed tomography strategy to quantify and localize modeling and remodeling volumes over 4 weeks of concurrent PTH treatment and mechanical loading. Modeled and remodeled volumes are probed for differences with respect to treatment, loading, and interactions thereof in trabecular and cortical bone compartments, which were further separated by plate/rod microarchitecture and periosteal/endosteal surfaces, respectively. Loading effects are further considered independently with regard to localized strain environments. Our findings indicate that in trabecular bone, PTH and loading stimulate anabolic modeling additively, and remodeling synergistically. PTH tends to lead to bone accumulation indiscriminate of trabecular microarchitecture, whereas loading tends to more strongly affect plates than rods. The cortical surfaces responded uniquely to PTH and loading, with synergistic effects on the periosteal surface for anabolic modeling, and on the endosteal surface for catabolic modeling. The increase in catabolic modeling due to loading, which is enhanced by PTH, is concentrated to areas of the endosteal surface under low strain and to our knowledge has not previously been reported. Taken together, the effects of PTH, loading, and their interactions, are shown to be dependent on the specific bone compartment and metabolic regime; this may explain some discrepancies in previously-reported findings.
Collapse
Affiliation(s)
- Samuel T Robinson
- Bone Bioengineering Laboratory, 351 Engineering Terrace, Department of Biomedical Engineering, Columbia University, 1210 Amsterdam Avenue, New York, NY 10027, USA.
| | - Peter T Shyu
- Bone Bioengineering Laboratory, 351 Engineering Terrace, Department of Biomedical Engineering, Columbia University, 1210 Amsterdam Avenue, New York, NY 10027, USA.
| | - X Edward Guo
- Bone Bioengineering Laboratory, 351 Engineering Terrace, Department of Biomedical Engineering, Columbia University, 1210 Amsterdam Avenue, New York, NY 10027, USA.
| |
Collapse
|
7
|
Yu YE, Hu YJ, Zhou B, Wang J, Guo XE. Microstructure Determines Apparent-Level Mechanics Despite Tissue-Level Anisotropy and Heterogeneity of Individual Plates and Rods in Normal Human Trabecular Bone. J Bone Miner Res 2021; 36:1796-1807. [PMID: 33989436 DOI: 10.1002/jbmr.4338] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/08/2021] [Revised: 04/20/2021] [Accepted: 05/09/2021] [Indexed: 11/08/2022]
Abstract
Trabecular plates and rods determine apparent elastic modulus and yield strength of trabecular bone, serving as important indicators of bone's mechanical integrity in health and disease. Although trabecular bone's apparent-level mechanical properties have been widely reported, tissue mechanical properties of individual trabeculae have not been fully characterized. We systematically measured tissue mineral density (TMD)-dependent elastic modulus of individual trabeculae using microindentation and characterized its anisotropy as a function of trabecular type (plate or rod), trabecular orientation in the global coordinate (longitudinal, oblique, or transverse along the anatomic loading axis), and indentation direction along the local trabecular coordinate (axial or lateral). Human trabecular bone samples were scanned by micro-computed tomography for TMD and microstructural measurements. Individual trabecula segmentation was used to decompose trabecular network into individual trabeculae, where trabecular type and orientation were determined. We performed precise, selective indentation of trabeculae in each category using a custom-built, microscope-coupled microindentation device. Co-localization of TMD at each indentation site was performed to obtain TMD-to-modulus correlations. We found significantly higher TMD and tissue modulus in trabecular plates than rods. Regardless of trabecular type and orientation, axial tissue modulus was consistently higher than lateral tissue modulus, with ratios ranging from 1.13 to 1.41. Correlations between TMD and tissue modulus measured from axial and lateral indentations were strong but distinct: axial correlation predicted higher tissue modulus than lateral correlation at the same TMD level. To assess the contribution of experimentally measured anisotropic tissue properties of individual trabeculae to apparent-level mechanics, we constructed non-linear micro-finite element models using a new set of trabecular bone samples and compared model predictions to mechanical testing measurements. Heterogeneous anisotropic models accurately predicted apparent elastic modulus but were no better than a simple homogeneous isotropic model. Variances in tissue-level properties may therefore contribute nominally to apparent-level mechanics in normal human trabecular bone. © 2021 American Society for Bone and Mineral Research (ASBMR).
Collapse
Affiliation(s)
- Y Eric Yu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.,Department of Medical Imaging, Suzhou Institute of Biomedical Engineering and Technology, Chinese Academy of Sciences, Suzhou, China
| | - Yizhong Jenny Hu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Bin Zhou
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - Ji Wang
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA
| | - X Edward Guo
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA
| |
Collapse
|
8
|
Sacher S, Hernandez CJ, Donnelly E. Characterization of Ultralow Density Cellular Solids: Lessons from 30 years of Bone Biomechanics Research. ADVANCED ENGINEERING MATERIALS 2021; 23:2100206. [PMID: 34456625 PMCID: PMC8389487 DOI: 10.1002/adem.202100206] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/16/2021] [Indexed: 06/13/2023]
Abstract
Advances in additive manufacturing techniques have enabled the development of micro-architectured materials displaying a combination of low-density and lightweight structures with high specific strength and toughness. The mechanical performance of micro-architectured materials can be assessed using standard techniques; however, when studying low- and ultralow density micro-architectured materials, standard characterization techniques can be subject to experimental artifacts. Additionally, quantitative assessment and comparisons of microarchitectures with distinct lattice patterns is not always straightforward. Cancellous bone is a natural, ultralow density (porosity often exceeding 90%), irregular, cellular solid that has been thoroughly characterized in terms of micro-architecture and mechanical performance over the past 30 years. However, most the literature on cancellous bone mechanical properties and micro-structure-function relationships is in the medical literature and is not immediately accessible to materials designers. Here we provide a brief review of state-of-the-art approaches for characterizing the micro-architecture and mechanical performance of ultralow density cancellous bone, including methods of addressing experimental artifacts during mechanical characterization of ultralow density cellular solids, methods of quantifying microarchitecture, and currently understood structure-function relationships.
Collapse
Affiliation(s)
- Sara Sacher
- Department of Materials Science and Engineering, Cornell University, Ithaca, NY
| | - Christopher J Hernandez
- Research Division, Hospital for Special Surgery, New York, NY
- Sibley School of Mechanical and Aerospace Engineering, Cornell University, Ithaca, NY
| | - Eve Donnelly
- Department of Materials Science and Engineering, Cornell University, Ithaca, NY
- Research Division, Hospital for Special Surgery, New York, NY
| |
Collapse
|
9
|
Fluid-structure interaction (FSI) modeling of bone marrow through trabecular bone structure under compression. Biomech Model Mechanobiol 2021; 20:957-968. [PMID: 33547975 DOI: 10.1007/s10237-021-01423-x] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2020] [Accepted: 01/10/2021] [Indexed: 10/22/2022]
Abstract
The present study has sought to investigate the fluid characteristic and mechanical properties of trabecular bone using fluid-structure interaction (FSI) approach under different trabecular bone orientations. This method imposed on trabecular bone structure at both longitudinal and transverse orientations to identify effects on shear stress, permeability, stiffness and stress regarded to the trabeculae. Sixteen FSI models were performed on different range trabecular cubes of 27 mm3 with eight models developed for each longitudinal and transverse direction. Results show that there was a moderate correlation between permeability and porosity, and surface area in the longitudinal and transverse orientations. For the longitudinal orientation, the permeability values varied between 3.66 × 10-8 and 1.9 × 10-7 and the sheer stress values varied between 0.05 and 1.8 Pa, whilst for the transverse orientation, the permeability values varied between 5.95 × 10-10 and 1.78 × 10-8 and the shear stress values varied between 0.04 and 3.1 Pa. Here, transverse orientation limits the fluid flow from passing through the trabeculae due to high shear stress disturbance generated within the trabecular bone region. Compared to physiological loading direction (longitudinal orientation), permeability is higher within the range known to trigger a response in bone cells. Additionally, shear stresses also increase with bone surface area. This study suggests the shear stress within bone marrow in real trabecular architecture could provide the mechanical signal to marrow cells that leads to bone anabolism and can depend on trabecular orientation.
Collapse
|
10
|
Brasinika D, Koumoulos EP, Kyriakidou K, Gkartzou E, Kritikou M, Karoussis IK, Charitidis CA. Mechanical Enhancement of Cytocompatible 3D Scaffolds, Consisting of Hydroxyapatite Nanocrystals and Natural Biomolecules, Through Physical Cross-Linking. Bioengineering (Basel) 2020; 7:bioengineering7030096. [PMID: 32825042 PMCID: PMC7552716 DOI: 10.3390/bioengineering7030096] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2020] [Revised: 08/12/2020] [Accepted: 08/15/2020] [Indexed: 11/16/2022] Open
Abstract
Bioinspired scaffolds mimicking natural bone-tissue properties holds great promise in tissue engineering applications towards bone regeneration. Within this work, a way to reinforce mechanical behavior of bioinspired bone scaffolds was examined by applying a physical crosslinking method. Scaffolds consisted of hydroxyapatite nanocrystals, biomimetically synthesized in the presence of collagen and l-arginine. Scaffolds were characterized by X-ray diffraction, Fourier transform infrared spectroscopy, scanning electron microscopy (SEM), microcomputed tomography, and nanoindentation. Results revealed scaffolds with bone-like nanostructure and composition, thus an inherent enhanced cytocompatibility. Evaluation of porosity proved the development of interconnected porous network with bimodal pore size distribution. Mechanical reinforcement was achieved through physical crosslinking with riboflavin irradiation, and nanoindentation tests indicated that within the experimental conditions of 45% humidity and 37 °C, photo-crosslinking led to an increase in the scaffold’s mechanical properties. Elastic modulus and hardness were augmented, and specifically elastic modulus values were doubled, approaching equivalent values of trabecular bone. Cytocompatibility of the scaffolds was assessed using MG63 human osteosarcoma cells. Cell viability was evaluated by double staining and MTT assay, while attachment and morphology were investigated by SEM. The results suggested that scaffolds provided a cell friendly environment with high levels of viability, thus supporting cell attachment, spreading and proliferation.
Collapse
Affiliation(s)
- Despoina Brasinika
- BioG3D–New 3D printing technologies, 1 Lavriou Str., Technological & Cultural Park of Lavrion, 19500 Lavrion, Greece;
| | - Elias P. Koumoulos
- School of Chemical Engineering, National Technical University of Athens, 9 Iroon Polytechniou Str., Zografou Campus, 15780 Athens, Greece; (E.P.K.); (E.G.); (M.K.)
| | - Kyriaki Kyriakidou
- School of Dentistry, National and Kapodistrian University of Athens, 2 Thivon Str., Goudi, 11527 Athens, Greece; (K.K.); (I.K.K.)
| | - Eleni Gkartzou
- School of Chemical Engineering, National Technical University of Athens, 9 Iroon Polytechniou Str., Zografou Campus, 15780 Athens, Greece; (E.P.K.); (E.G.); (M.K.)
| | - Maria Kritikou
- School of Chemical Engineering, National Technical University of Athens, 9 Iroon Polytechniou Str., Zografou Campus, 15780 Athens, Greece; (E.P.K.); (E.G.); (M.K.)
| | - Ioannis K. Karoussis
- School of Dentistry, National and Kapodistrian University of Athens, 2 Thivon Str., Goudi, 11527 Athens, Greece; (K.K.); (I.K.K.)
| | - Costas A. Charitidis
- School of Chemical Engineering, National Technical University of Athens, 9 Iroon Polytechniou Str., Zografou Campus, 15780 Athens, Greece; (E.P.K.); (E.G.); (M.K.)
- Correspondence: ; Tel.: +30-2107724046
| |
Collapse
|
11
|
Dai C, Jia J, Kot A, Liu X, Liu L, Jiang M, Lane NE, Wise BL, Yao W. Selective inhibition of progesterone receptor in osteochondral progenitor cells, but not in mature chondrocytes, modulated subchondral bone structures. Bone 2020; 132:115196. [PMID: 31863959 PMCID: PMC7006606 DOI: 10.1016/j.bone.2019.115196] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/16/2019] [Revised: 12/16/2019] [Accepted: 12/17/2019] [Indexed: 01/12/2023]
Abstract
OBJECTIVE The presence or relative proportion of progesterone nuclear receptors (PR) in different tissues may contribute to sexual dimorphism in these tissues. PR is expressed in chondrocytes, but its function is mostly unknown. We hypothesized that the PR may regulate chondrocyte metabolism and affect subchondral bone structure. METHODS We utilized genetic fate mapping and immunohistochemistry to elucidate PR expression in and effect on cartilage. To define sex-dependent and chondrocyte-specific effects of the PR on subchondral bone, we selectively deleted PR in osteochondrogenic progenitor cells marked by Prx1 (Prx1; PRcKO) and Collagen 2 (Col2; PRcKO), or in matured chondrocytes marked by aggrecan (Acan; PRcKO) and evaluated subchondral bone structure at 4 months of age. Chondrocyte aging was monitored by anti-senescence marker p16INK4a, and MMP13, one of the Senescence-Associated Secretary Phenotype (SASP) components. RESULTS Compared to wild-type (WT) mice, the female Prx1; PRcKO and the Col2; PRcKO mice had greater total subchondral bone volume and greater subchondral cortical bone thickness, with increased estimated subchondral bone stiffness and failure load in both female and male Col2; PRcKO mice. Moreover, Col2; PRcKO mice from both sexes had greater bone formation and bone strength at the femurs. In contrast, we did not observe any subchondral bone changes in Acan; PRcKO mice other than higher work-to-failure observed in the male Acan; PRcKO mice. Despite no detected difference in articular cartilage between the WT and the PR; chondrocyte conditional deletion mice, there were greater numbers of senescent chondrocytes and increased MMP13 expression, especially in the male mutant mice. CONCLUSION These findings suggest that selective inhibition of PR in osteoprogenitor cells, but not in terminally differentiated chondrocytes, induced an increased subchondral bone phenotype and high estimated subchondral bone strength, which might be associated with the development of osteoarthritis in older age.
Collapse
Affiliation(s)
- Chenlin Dai
- Center for Musculoskeletal Health, Department of Internal Medicine, University of California, Davis Medical Center, Sacramento, CA 95817, USA
| | - Junjing Jia
- Center for Musculoskeletal Health, Department of Internal Medicine, University of California, Davis Medical Center, Sacramento, CA 95817, USA
| | - Alexander Kot
- Center for Musculoskeletal Health, Department of Internal Medicine, University of California, Davis Medical Center, Sacramento, CA 95817, USA
| | - Xueping Liu
- Center for Musculoskeletal Health, Department of Internal Medicine, University of California, Davis Medical Center, Sacramento, CA 95817, USA
| | - Lixian Liu
- Center for Musculoskeletal Health, Department of Internal Medicine, University of California, Davis Medical Center, Sacramento, CA 95817, USA
| | - Min Jiang
- Center for Musculoskeletal Health, Department of Internal Medicine, University of California, Davis Medical Center, Sacramento, CA 95817, USA
| | - Nancy E Lane
- Center for Musculoskeletal Health, Department of Internal Medicine, University of California, Davis Medical Center, Sacramento, CA 95817, USA
| | - Barton L Wise
- Center for Musculoskeletal Health, Department of Internal Medicine, University of California, Davis Medical Center, Sacramento, CA 95817, USA; Department of Orthopaedic Surgery, University of California, Davis Medical Center, Sacramento, CA 95817, USA
| | - Wei Yao
- Center for Musculoskeletal Health, Department of Internal Medicine, University of California, Davis Medical Center, Sacramento, CA 95817, USA.
| |
Collapse
|
12
|
Shi Q, Shui H, Chen Q, Li ZY. How does mechanical stimulus affect the coupling process of the scaffold degradation and bone formation: An in silico approach. Comput Biol Med 2020; 117:103588. [DOI: 10.1016/j.compbiomed.2019.103588] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2019] [Revised: 12/03/2019] [Accepted: 12/17/2019] [Indexed: 01/31/2023]
|
13
|
Singhal V, Bose A, Liang Y, Srivastava G, Goode S, Stanford FC, Misra M, Bredella MA. Marrow adipose tissue in adolescent girls with obesity. Bone 2019; 129:115103. [PMID: 31622774 PMCID: PMC6842661 DOI: 10.1016/j.bone.2019.115103] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/09/2019] [Revised: 09/26/2019] [Accepted: 10/06/2019] [Indexed: 02/04/2023]
Abstract
BACKGROUND Marrow adipose tissue (MAT) is increasingly recognized as an active and dynamic endocrine organ that responds to changes in nutrition and environmental milieu. Compared to normal weight controls, adolescent girls with anorexia nervosa have higher MAT content, which is associated with impaired skeletal integrity, but data are limited regarding MAT content in adolescents with obesity and how this interacts with bone endpoints. OBJECTIVE To evaluate (i) MAT content in adolescents with obesity compared to normal-weight controls, (ii) the association of MAT with bone endpoints, and (iii) whether these associations of MAT are affected by body weight. METHODS We assessed MAT, bone endpoints, and body composition in 60 adolescent girls 14-21 years old: 45 with obesity (OB) and 15 normal-weight controls (NW-C). We used (i) DXA to assess areal bone mineral density (aBMD) at the lumbar spine and total hip, and total body fat and lean mass, (ii) proton magnetic resonance spectroscopy (1H-MRS) to assess MAT at the 4th lumbar vertebra and femur, and MRI to assess visceral (VAT) and subcutaneous adipose tissue (SAT), (iii) high resolution peripheral quantitative CT (HR-pQCT) to assess volumetric BMD (vBMD), (iv) individual trabeculae segmentation to evaluate trabecular bone (plate-rod morphology), and (v) finite element analysis to assess stiffness (a strength estimate) at the distal radius and tibia. RESULTS Groups did not differ for age or height. Weight, BMI, and areal BMD Z-scores at all sites were higher in the OB group (p<0.0001). MAT was lower in OB at the femoral diaphysis (p= <0.0001) and the lumbar spine (p=0.0039). For the whole group, MAT at the lumbar spine and femoral diaphysis was inversely associated with BMI, total fat mass, lean mass, and VAT. Even after controlling for body weight, independent inverse associations were observed of femoral diaphyseal and lumbar MAT with total tibial vBMD, and of lumbar MAT with radial trabecular vBMD. CONCLUSION Adolescent girls with obesity have lower MAT than normal-weight controls despite having an excess of total body fat. These findings confirm that MAT is regulated uniquely from other adipose depots in obesity. MAT was inversely associated with vBMD, emphasizing an inverse relationship between MAT and bone even in adolescent girls with obesity.
Collapse
Affiliation(s)
- Vibha Singhal
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States; Division of Pediatric Endocrinology, Massachusetts General Hospital for Children and Harvard Medical School, United States; Massachusetts General Hospital Weight Center, United States
| | - Amita Bose
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States
| | - Yini Liang
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States
| | - Gitanjali Srivastava
- Department of Medicine, Section on Endocrinology, Diabetes, Nutrition & Weight Management, Boston Medical Center, United States; Department of Medicine, Division of Diabetes, Endocrinology & Metabolism, Vanderbilt University School of Medicine, United States; Department of Pediatrics, Vanderbilt University School of Medicine, United States
| | - Susan Goode
- Division of Pediatric Gastroenterology, Massachusetts General Hospital for Children and Harvard Medical School, United States
| | - Fatima Cody Stanford
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States; Division of Pediatric Endocrinology, Massachusetts General Hospital for Children and Harvard Medical School, United States; Massachusetts General Hospital Weight Center, United States
| | - Madhusmita Misra
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States; Division of Pediatric Endocrinology, Massachusetts General Hospital for Children and Harvard Medical School, United States
| | - Miriam A Bredella
- Department of Radiology, Massachusetts General Hospital and Harvard Medical School, United States.
| |
Collapse
|
14
|
Abstract
Microarchitectured materials achieve superior mechanical properties through geometry rather than composition. Although ultralightweight microarchitectured materials can have high stiffness and strength, application to durable devices will require sufficient service life under cyclic loading. Naturally occurring materials provide useful models for high-performance materials. Here, we show that in cancellous bone, a naturally occurring lightweight microarchitectured material, resistance to fatigue failure is sensitive to a microarchitectural trait that has negligible effects on stiffness and strength-the proportion of material oriented transverse to applied loads. Using models generated with additive manufacturing, we show that small increases in the thickness of elements oriented transverse to loading can increase fatigue life by 10 to 100 times, far exceeding what is expected from the associated change in density. Transversely oriented struts enhance resistance to fatigue by acting as sacrificial elements. We show that this mechanism is also present in synthetic microlattice structures, where fatigue life can be altered by 5 to 9 times with only negligible changes in density and stiffness. The effects of microstructure on fatigue life in cancellous bone and lattice structures are described empirically by normalizing stress in traditional stress vs. life (S-N) curves by √ψ, where ψ is the proportion of material oriented transverse to load. The mechanical performance of cancellous bone and microarchitectured materials is enhanced by aligning structural elements with expected loading; our findings demonstrate that this strategy comes at the cost of reduced fatigue life, with consequences to the use of microarchitectured materials in durable devices and to human health in the context of osteoporosis.
Collapse
|
15
|
Schorr M, Fazeli PK, Bachmann KN, Faje AT, Meenaghan E, Kimball A, Singhal V, Ebrahimi S, Gleysteen S, Mickley D, Eddy KT, Misra M, Klibanski A, Miller KK. Differences in Trabecular Plate and Rod Structure in Premenopausal Women Across the Weight Spectrum. J Clin Endocrinol Metab 2019; 104:4501-4510. [PMID: 31219580 PMCID: PMC6735760 DOI: 10.1210/jc.2019-00843] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/08/2019] [Accepted: 06/12/2019] [Indexed: 12/21/2022]
Abstract
CONTEXT Premenopausal women with anorexia nervosa (AN) and obesity (OB) have elevated fracture risk. More plate-like and axially aligned trabecular bone, assessed by individual trabeculae segmentation (ITS), is associated with higher estimated bone strength. Trabecular plate and rod structure has not been reported across the weight spectrum. OBJECTIVE To investigate trabecular plate and rod structure in premenopausal women. DESIGN Cross-sectional study. SETTING Clinical research center. PARTICIPANTS A total of 105 women age 21 to 46 years: (i) women with AN (n = 46), (ii) eumenorrheic lean healthy controls (HCs) (n = 29), and (iii) eumenorrheic women with OB (n = 30). MEASURES Trabecular microarchitecture by ITS. RESULTS Mean age (±SD) was similar (28.9 ± 6.3 years) and body mass index differed (16.7 ± 1.8 vs 22.6 ± 1.4 vs 35.1 ± 3.3 kg/m2; P < 0.0001) across groups. Bone was less plate-like and axially aligned in AN (P ≤ 0.01) and did not differ between OB and HC. After controlling for weight, plate and axial bone volume fraction and plate number density were lower in OB vs HC; some were lower in OB than AN (P < 0.05). The relationship between weight and plate variables was quadratic (R = 0.39 to 0.70; P ≤ 0.0006) (i.e., positive associations were attenuated at high weight). Appendicular lean mass and IGF-1 levels were positively associated with plate variables (R = 0.27 to 0.67; P < 0.05). Amenorrhea was associated with lower radial plate variables than eumenorrhea in AN (P < 0.05). CONCLUSIONS In women with AN, trabecular bone is less plate-like. In women with OB, trabecular plates do not adapt to high weight. This is relevant because trabecular plates are associated with greater estimated bone strength. Higher muscle mass and IGF-1 levels may mitigate some of the adverse effects of low weight or excess adiposity on bone.
Collapse
Affiliation(s)
- Melanie Schorr
- Neuroendocrine Unit, Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School, Boston, Massachusetts
- Correspondence and Reprint Requests: Melanie Schorr, MD, Neuroendocrine Unit, Massachusetts General Hospital, 55 Fruit Street, Bulfinch 457B, Boston, Massachusetts 02114. E-mail:
| | - Pouneh K Fazeli
- Neuroendocrine Unit, Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School, Boston, Massachusetts
| | - Katherine N Bachmann
- Neuroendocrine Unit, Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School, Boston, Massachusetts
| | - Alexander T Faje
- Neuroendocrine Unit, Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School, Boston, Massachusetts
| | - Erinne Meenaghan
- Neuroendocrine Unit, Massachusetts General Hospital, Boston, Massachusetts
| | - Allison Kimball
- Neuroendocrine Unit, Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School, Boston, Massachusetts
| | - Vibha Singhal
- Neuroendocrine Unit, Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School, Boston, Massachusetts
- Pediatric Endocrine Unit, Massachusetts General Hospital, Boston, Massachusetts
| | - Seda Ebrahimi
- Cambridge Eating Disorder Center, Cambridge, Massachusetts
| | - Suzanne Gleysteen
- Harvard Medical School, Boston, Massachusetts
- Beth Israel Deaconess Medical Center, Boston, Massachusetts
| | - Diane Mickley
- Wilkins Center for Eating Disorders, Greenwich, Connecticut
| | - Kamryn T Eddy
- Harvard Medical School, Boston, Massachusetts
- Eating Disorders Clinical and Research Program, Massachusetts General Hospital, Boston, Massachusetts
| | - Madhusmita Misra
- Neuroendocrine Unit, Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School, Boston, Massachusetts
- Pediatric Endocrine Unit, Massachusetts General Hospital, Boston, Massachusetts
| | - Anne Klibanski
- Neuroendocrine Unit, Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School, Boston, Massachusetts
| | - Karen K Miller
- Neuroendocrine Unit, Massachusetts General Hospital, Boston, Massachusetts
- Harvard Medical School, Boston, Massachusetts
| |
Collapse
|
16
|
Singhal V, Sanchita S, Malhotra S, Bose A, Flores LPT, Valera R, Stanford FC, Slattery M, Rosenblum J, Goldstein MA, Schorr M, Ackerman KE, Miller KK, Klibanski A, Bredella MA, Misra M. Suboptimal bone microarchitecure in adolescent girls with obesity compared to normal-weight controls and girls with anorexia nervosa. Bone 2019; 122:246-253. [PMID: 30853658 PMCID: PMC6636859 DOI: 10.1016/j.bone.2019.03.007] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 03/05/2019] [Accepted: 03/06/2019] [Indexed: 12/13/2022]
Abstract
BACKGROUND Despite their higher areal bone mineral density (aBMD), adolescents with obesity (OB) have an increase in fracture risk, particularly of the extremities, compared with normal-weight controls. Whereas bone parameters that increase fracture risk are well characterized in anorexia nervosa (AN), the other end of nutritional spectrum, these data are lacking in adolescents with obesity. OBJECTIVE Our objective was to compare bone parameters in adolescent girls across the nutritional spectrum, to determine whether suboptimal bone adaptation to increased body weight may explain the increased fracture risk in OB. METHODS We assessed bone endpoints in 153 adolescent girls 14-21 years old: 50 OB, 48 controls and 55 AN. We used (i) DXA to assess aBMD at the lumbar spine, proximal femur and whole body, and body composition, (ii) high resolution peripheral quantitative CT (HRpQCT) to assess bone geometry, microarchitecture and volumetric BMD (vBMD), and (iii) finite element analysis to assess failure load (a strength estimate) at the distal radius and tibia. All aBMD, microarchitecture and FEA analyses were controlled for age and race. RESULTS Groups did not differ for age or height. Areal BMD Z-scores at all sites were highest in OB, intermediate in controls and lowest in AN (p < 0.0001). At the radius, cortical area and thickness were higher in OB compared to AN and control groups (p = 0.001) while trabecular area did not differ across groups. Compared to controls, OB had higher cortical porosity (p = 0.003), higher trabecular thickness (p = 0.024), and higher total, cortical and trabecular vBMD and rod BV/TV (p < 0.04). Plate BV/TV did not differ in OB vs. controls, but was higher than in AN (p = 0.001). At the tibia, total, cortical, and trabecular area and cortical thickness were higher in OB vs. controls and AN (p < 0.005). OB also had higher cortical porosity (p < 0.007) and lower trabecular thickness (p < 0.02) than the other two groups. Trabecular number, total and trabecular vBMD, and rod BV/TV were higher in OB vs. controls and AN (p < 0.02), while cortical vBMD and plate BV/TV did not differ in OB vs. the other two groups. Finally, failure load (a strength estimate) was higher in OB at the radius and tibia compared to controls and AN (p < 0.004 for all). However, after adjusting for body weight, failure load was lower in OB vs. controls at both sites (p < 0.05), and lower than in AN at the distal tibia. CONCLUSION Not all bone parameters demonstrate appropriate adaptation to higher body weight. Cortical porosity and plate BV/TV at the radius and tibia, and cortical vBMD and trabecular thickness at the tibia are particularly at risk. These effects may contribute to the higher risk for fracture reported in OB vs. controls.
Collapse
Affiliation(s)
- Vibha Singhal
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States of America; Division of Pediatric Endocrinology, Massachusetts General Hospital for Children, Harvard Medical School, United States of America; MGH Weight Center, United States of America.
| | - Smriti Sanchita
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Sonali Malhotra
- Division of Pediatric Endocrinology, Massachusetts General Hospital for Children, Harvard Medical School, United States of America
| | - Amita Bose
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Landy Paola Torre Flores
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Ruben Valera
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Fatima Cody Stanford
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States of America; MGH Weight Center, United States of America
| | - Meghan Slattery
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Jennifer Rosenblum
- Division of Adolescent Medicine, Massachusetts General Hospital for Children, Harvard Medical School, United States of America
| | - Mark A Goldstein
- Division of Adolescent Medicine, Massachusetts General Hospital for Children, Harvard Medical School, United States of America
| | - Melanie Schorr
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Kathryn E Ackerman
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States of America; Divison of Sports Medicine, Boston Children's Hospital, Harvard Medical School, United States of America
| | - Karen K Miller
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Anne Klibanski
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States of America
| | - Miriam A Bredella
- Department of Radiology, Massachusetts General Hospital, Harvard Medical School, United States of America
| | - Madhusmita Misra
- Neuroendocrine Unit, Massachusetts General Hospital and Harvard Medical School, United States of America; Division of Pediatric Endocrinology, Massachusetts General Hospital for Children, Harvard Medical School, United States of America
| |
Collapse
|
17
|
Ishimoto T, Yamada K, Takahashi H, Takahata M, Ito M, Hanawa T, Nakano T. Trabecular health of vertebrae based on anisotropy in trabecular architecture and collagen/apatite micro-arrangement after implantation of intervertebral fusion cages in the sheep spine. Bone 2018; 108:25-33. [PMID: 29241826 DOI: 10.1016/j.bone.2017.12.012] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/17/2017] [Revised: 12/07/2017] [Accepted: 12/10/2017] [Indexed: 11/22/2022]
Abstract
Healthy trabecular bone shows highly anisotropic trabecular architecture and the preferential orientation of collagen and apatite inside a trabecula, both of which are predominantly directed along the cephalocaudal axis. This makes trabecular bone stiff in the principally loaded direction (cephalocaudal axis). However, changes in these anisotropic trabecular characteristics after the insertion of implant devices remain unclear. We defined the trabecular architectural anisotropy and the preferential orientation of collagen and apatite as parameters of trabecular bone health. In the present study, we analyzed these parameters after the implantation of two types of intervertebral fusion cages, open and closed box-type cages, into sheep spines for 2 and 4months. Alteration and evolution of trabecular health around and inside the cages depended on the cage type and implantation duration. At the boundary region, the values of trabecular architectural anisotropy and apatite orientation for the closed-type cages were similar to those for isotropic conditions. In contrast, significantly larger anisotropy was found for open-type cages, indicating that the open-type cage tended to maintain trabecular anisotropy. Inside the open-type cage, trabecular architectural anisotropy and apatite orientation significantly increased with time after implantation. Assessing trabecular anisotropy might be useful for the evaluation of trabecular health and the validation and refinement of implant designs.
Collapse
Affiliation(s)
- Takuya Ishimoto
- Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, 2-1, Yamada-Oka, Suita, Osaka 565-0871, Japan
| | - Katsuhisa Yamada
- Department of Orthopedic Surgery, Graduate School of Medicine, Hokkaido University, North-15, West-7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan
| | - Hiroyuki Takahashi
- Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, 2-1, Yamada-Oka, Suita, Osaka 565-0871, Japan; Teijin Nakashima Medical Co., Ltd., 688-1 Joto-Kitagata, Higashi-ku, Okayama 709-0625, Japan
| | - Masahiko Takahata
- Department of Orthopedic Surgery, Graduate School of Medicine, Hokkaido University, North-15, West-7, Kita-ku, Sapporo, Hokkaido 060-8638, Japan
| | - Manabu Ito
- Department of Spine and Spinal Cord Disorders, National Hospital Organization, Hokkaido Medical Center, 5-7-1-1 Yamanote, Nishi-ku, Sapporo, Hokkaido 063-0005, Japan
| | - Takao Hanawa
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University, Kanda-surugadai, Chiyoda-ku, Tokyo 101-0062, Japan
| | - Takayoshi Nakano
- Division of Materials and Manufacturing Science, Graduate School of Engineering, Osaka University, 2-1, Yamada-Oka, Suita, Osaka 565-0871, Japan.
| |
Collapse
|
18
|
Gorgieva S, Girandon L, Kokol V. Mineralization potential of cellulose-nanofibrils reinforced gelatine scaffolds for promoted calcium deposition by mesenchymal stem cells. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2016; 73:478-489. [PMID: 28183635 DOI: 10.1016/j.msec.2016.12.092] [Citation(s) in RCA: 39] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/08/2016] [Revised: 10/30/2016] [Accepted: 12/19/2016] [Indexed: 11/20/2022]
Abstract
Cellulose-nanofibrils (CNFs) enriched gelatine (GEL) scaffolds were fabricated in-situ by the combined freeze-thawing process and carbodiimide crosslinking chemistry. The original- and variously surface anionised CNFs (carboxylated/CNF-COOH/, and phosphonated with 3-AminoPropylphosphoric Acid/CNF-COOH-ApA/) were used in order to tune the scaffolds' biomimetic structure towards a more intensive mineralization process. The pore size reduction (from 208±35μm to 91±35μm) after 50% v/v of CNFs addition to GEL was identified, while separated pore-walls' alignment vs. shorter, dense and elongated pores are observed when using 80% v/v of original-CNFs vs. anionised-CNFs, all of them possessed osteoid-like compressive strength (0.025-0.40MPa) and elasticity (0.04-0.15MPa). While randomly distributed Ca2+-deficient hydroxyapatite/HAp/(Ca/P≈1.4) aggregates were identified in the case of original-CNF prevalent scaffolds after four weeks of incubation in SBF, the more uniform and intensified deposition with HAp-like (Ca/P≈1.69) structures were established using CNF-COOH-Apa. The growth of Mesenchymal Stem Cells (MSCs) was observed on all CNF-containing scaffolds, resulting in more extensive Ca2+ deposition compared to the positive control or pure GEL scaffold. Among them, the scaffold prepared with the 50% v/v CNF-COOH-ApA showed significantly increased mineralization kinetic as well as the capacity for bone-like patterning in bone tissue regeneration.
Collapse
Affiliation(s)
- Selestina Gorgieva
- University of Maribor, Institute of Engineering Materials and Design, Maribor, Slovenia
| | | | - Vanja Kokol
- University of Maribor, Institute of Engineering Materials and Design, Maribor, Slovenia.
| |
Collapse
|
19
|
Ryan JW, Starczak Y, Tsangari H, Sawyer RK, Davey RA, Atkins GJ, Morris HA, Anderson PH. Sex-related differences in the skeletal phenotype of aged vitamin D receptor global knockout mice. J Steroid Biochem Mol Biol 2016; 164:361-368. [PMID: 26690785 DOI: 10.1016/j.jsbmb.2015.12.005] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2015] [Revised: 11/09/2015] [Accepted: 12/06/2015] [Indexed: 10/22/2022]
Abstract
The role of the vitamin D receptor (VDR) in maintaining skeletal health appears to be complex and dependent on the physiological context. Global Vdr deletion in a mouse model (Vdr-/-) results in hypocalcemia, secondary hyperparathyroidism and bone features typical of vitamin D-dependent rickets type II. When weanling Vdr-/- mice are fed a diet containing high levels of calcium, phosphorus and lactose, termed the rescue diet, normalisation of serum calcium, phosphate and parathyroid hormone levels results in prevention of rickets at 10 weeks of age. However, 17 week old male Vdr-/- mice, fed the rescue diet, have been reported as osteopenic due to a decrease in bone formation when compared to wild type mice. We now report confirmation of this finding with further data on the effect of the rescue diet on appendicular and axial skeletal structures in male and female Vdr-/- mice at 26 weeks of age compared to Vdr+/- controls. All Vdr-/- mice were normocalcemic with no evidence of any mineralization defect. However, male Vdr-/- mice exhibited significantly reduced mineral in femoral and vertebral bones when compared to control littermate Vdr+/- mice, consistent with the previously reported data. In contrast, 26-week-old female Vdr-/- mice demonstrated significantly increased femoral trabecular bone volume although there was decreased vertebral trabecular bone volume, similar to males, and femoral cortical bone volume was unchanged. Thus, the Vdr-/- mouse model displays sex- and site-specific differences in skeletal structures with long-term feeding of a rescue diet. Although the global Vdr-/- ablation does not permit the determination of skeletal mechanisms producing these differences, these data confirm skeletal changes even when fed the rescue diet.
Collapse
Affiliation(s)
- Jackson W Ryan
- School of Pharmacy and Medical Sciences, Sansom Institute, University of South Australia, Adelaide, SA 5001, Australia; Department of Medicine, Austin Health, University of Melbourne, Heidelberg, VIC, Australia; Centre for Orthopaedic and Trauma Research, School of Medicine, University of Adelaide, Adelaide, SA 5001, Australia
| | - Yolandi Starczak
- School of Pharmacy and Medical Sciences, Sansom Institute, University of South Australia, Adelaide, SA 5001, Australia; Department of Medicine, Austin Health, University of Melbourne, Heidelberg, VIC, Australia; Centre for Orthopaedic and Trauma Research, School of Medicine, University of Adelaide, Adelaide, SA 5001, Australia
| | - Helen Tsangari
- School of Pharmacy and Medical Sciences, Sansom Institute, University of South Australia, Adelaide, SA 5001, Australia; Department of Medicine, Austin Health, University of Melbourne, Heidelberg, VIC, Australia; Centre for Orthopaedic and Trauma Research, School of Medicine, University of Adelaide, Adelaide, SA 5001, Australia
| | - Rebecca K Sawyer
- School of Pharmacy and Medical Sciences, Sansom Institute, University of South Australia, Adelaide, SA 5001, Australia; Department of Medicine, Austin Health, University of Melbourne, Heidelberg, VIC, Australia; Centre for Orthopaedic and Trauma Research, School of Medicine, University of Adelaide, Adelaide, SA 5001, Australia
| | - Rachel A Davey
- School of Pharmacy and Medical Sciences, Sansom Institute, University of South Australia, Adelaide, SA 5001, Australia; Department of Medicine, Austin Health, University of Melbourne, Heidelberg, VIC, Australia; Centre for Orthopaedic and Trauma Research, School of Medicine, University of Adelaide, Adelaide, SA 5001, Australia
| | - Gerald J Atkins
- School of Pharmacy and Medical Sciences, Sansom Institute, University of South Australia, Adelaide, SA 5001, Australia; Department of Medicine, Austin Health, University of Melbourne, Heidelberg, VIC, Australia; Centre for Orthopaedic and Trauma Research, School of Medicine, University of Adelaide, Adelaide, SA 5001, Australia
| | - Howard A Morris
- School of Pharmacy and Medical Sciences, Sansom Institute, University of South Australia, Adelaide, SA 5001, Australia; Department of Medicine, Austin Health, University of Melbourne, Heidelberg, VIC, Australia; Centre for Orthopaedic and Trauma Research, School of Medicine, University of Adelaide, Adelaide, SA 5001, Australia,.
| | - Paul H Anderson
- School of Pharmacy and Medical Sciences, Sansom Institute, University of South Australia, Adelaide, SA 5001, Australia; Department of Medicine, Austin Health, University of Melbourne, Heidelberg, VIC, Australia; Centre for Orthopaedic and Trauma Research, School of Medicine, University of Adelaide, Adelaide, SA 5001, Australia
| |
Collapse
|
20
|
Wang J, Stein EM, Zhou B, Nishiyama KK, Yu YE, Shane E, Guo XE. Deterioration of trabecular plate-rod and cortical microarchitecture and reduced bone stiffness at distal radius and tibia in postmenopausal women with vertebral fractures. Bone 2016; 88:39-46. [PMID: 27083398 PMCID: PMC4899124 DOI: 10.1016/j.bone.2016.04.003] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/14/2015] [Revised: 03/07/2016] [Accepted: 04/04/2016] [Indexed: 10/21/2022]
Abstract
Postmenopausal women with vertebral fractures have abnormal bone microarchitecture at the distal radius and tibia by HR-pQCT, independent of areal BMD. However, whether trabecular plate and rod microarchitecture is altered in women with vertebral fractures is unknown. This study aims to characterize the abnormalities of trabecular plate and rod microarchitecture, cortex, and bone stiffness in postmenopausal women with vertebral fractures. HR-pQCT images of distal radius and tibia were acquired from 45 women with vertebral fractures and 45 control subjects without fractures. Trabecular and cortical compartments were separated by an automatic segmentation algorithm and subjected to individual trabecula segmentation (ITS) analysis for measuring trabecular plate and rod morphology and cortical bone evaluation for measuring cortical thickness and porosity, respectively. Whole bone and trabecular bone stiffness were estimated by finite element analysis. Fracture and control subjects did not differ according to age, race, body mass index, osteoporosis risk factors, or medication use. Women with vertebral fractures had thinner cortices, and larger trabecular area compared to the control group. By ITS analysis, fracture subjects had fewer trabecular plates, less axially aligned trabeculae and less trabecular connectivity at both the radius and the tibia. Fewer trabecular rods were observed at the radius. Whole bone stiffness and trabecular bone stiffness were 18% and 22% lower in women with vertebral fractures at the radius, and 19% and 16% lower at the tibia, compared with controls. The estimated failure load of the radius and tibia were also reduced in the fracture subjects by 13% and 14%, respectively. In summary, postmenopausal women with vertebral fractures had both trabecular and cortical microstructural deterioration at the peripheral skeleton, with a preferential loss of trabecular plates and cortical thinning. These microstructural deficits translated into lower whole bone and trabecular bone stiffness at the radius and tibia. Our results suggest that abnormalities in trabecular plate and rod microstructure may be important mechanisms of vertebral fracture in postmenopausal women.
Collapse
Affiliation(s)
- Ji Wang
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| | - Emily M Stein
- Department of Medicine, College of Physicians and Surgeons, Columbia University, New York, NY, USA.
| | - Bin Zhou
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| | - Kyle K Nishiyama
- Department of Medicine, College of Physicians and Surgeons, Columbia University, New York, NY, USA.
| | - Y Eric Yu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| | - Elizabeth Shane
- Department of Medicine, College of Physicians and Surgeons, Columbia University, New York, NY, USA.
| | - X Edward Guo
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| |
Collapse
|
21
|
Wen XX, Xu C, Zong CL, Feng YF, Ma XY, Wang FQ, Yan YB, Lei W. Relationship between sample volumes and modulus of human vertebral trabecular bone in micro-finite element analysis. J Mech Behav Biomed Mater 2016; 60:468-475. [PMID: 26999702 DOI: 10.1016/j.jmbbm.2016.03.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2016] [Revised: 03/04/2016] [Accepted: 03/07/2016] [Indexed: 01/24/2023]
Abstract
Micro-finite element (μFE) models have been widely used to assess the biomechanical properties of trabecular bone. How to choose a proper sample volume of trabecular bone, which could predict the real bone biomechanical properties and reduce the calculation time, was an interesting problem. Therefore, the purpose of this study was to investigate the relationship between different sample volumes and apparent elastic modulus (E) calculated from μFE model. 5 Human lumbar vertebral bodies (L1-L5) were scanned by micro-CT. Cubic concentric samples of different lengths were constructed as the experimental groups and the largest possible volumes of interest (VOI) were constructed as the control group. A direct voxel-to-element approach was used to generate μFE models and steel layers were added to the superior and inferior surface to mimic axial compression tests. A 1% axial strain was prescribed to the top surface of the model to obtain the E values. ANOVA tests were performed to compare the E values from the different VOIs against that of the control group. Nonlinear function curve fitting was performed to study the relationship between volumes and E values. The larger cubic VOI included more nodes and elements, and more CPU times were needed for calculations. E values showed a descending tendency as the length of cubic VOI decreased. When the volume of VOI was smaller than (7.34mm(3)), E values were significantly different from the control group. The fit function showed that E values approached an asymptotic values with increasing length of VOI. Our study demonstrated that apparent elastic modulus calculated from μFE models were affected by the sample volumes. There was a descending tendency of E values as the length of cubic VOI decreased. Sample volume which was not smaller than (7.34mm(3)) was efficient enough and timesaving for the calculation of E.
Collapse
Affiliation(s)
- Xin-Xin Wen
- Department of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi׳an, Shaanxi 710032, China
| | - Chao Xu
- Department of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi׳an, Shaanxi 710032, China
| | - Chun-Lin Zong
- State Key Laboratory of Military Stomatology, Department of Oral and Maxillofacial Surgery, School of Stomatology, Fourth Military Medical University, Xi'an, China
| | - Ya-Fei Feng
- Department of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi׳an, Shaanxi 710032, China
| | - Xiang-Yu Ma
- Department of Orthopedics, 463 Hospital of PLA, Shenyang, China
| | - Fa-Qi Wang
- Department of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi׳an, Shaanxi 710032, China
| | - Ya-Bo Yan
- Department of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi׳an, Shaanxi 710032, China.
| | - Wei Lei
- Department of Orthopedics, Xijing Hospital, Fourth Military Medical University, Xi׳an, Shaanxi 710032, China.
| |
Collapse
|
22
|
Wang J, Zhou B, Liu XS, Fields AJ, Sanyal A, Shi X, Adams M, Keaveny TM, Guo XE. Trabecular plates and rods determine elastic modulus and yield strength of human trabecular bone. Bone 2015; 72:71-80. [PMID: 25460571 PMCID: PMC4282941 DOI: 10.1016/j.bone.2014.11.006] [Citation(s) in RCA: 72] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/19/2014] [Revised: 11/10/2014] [Accepted: 11/12/2014] [Indexed: 10/24/2022]
Abstract
The microstructure of trabecular bone is usually perceived as a collection of plate-like and rod-like trabeculae, which can be determined from the emerging high-resolution skeletal imaging modalities such as micro-computed tomography (μCT) or clinical high-resolution peripheral quantitative CT (HR-pQCT) using the individual trabecula segmentation (ITS) technique. It has been shown that the ITS-based plate and rod parameters are highly correlated with elastic modulus and yield strength of human trabecular bone. In the current study, plate-rod (PR) finite element (FE) models were constructed completely based on ITS-identified individual trabecular plates and rods. We hypothesized that PR FE can accurately and efficiently predict elastic modulus and yield strength of human trabecular bone. Human trabecular bone cores from proximal tibia (PT), femoral neck (FN) and greater trochanter (GT) were scanned by μCT. Specimen-specific ITS-based PR FE models were generated for each μCT image and corresponding voxel-based FE models were also generated in comparison. Both types of specimen-specific models were subjected to nonlinear FE analysis to predict the apparent elastic modulus and yield strength using the same trabecular bone tissue properties. Then, mechanical tests were performed to experimentally measure the apparent modulus and yield strength. Strong linear correlations for both elastic modulus (r(2) = 0.97) and yield strength (r(2) = 0.96) were found between the PR FE model predictions and experimental measures, suggesting that trabecular plate and rod morphology adequately captures three-dimensional (3D) microarchitecture of human trabecular bone. In addition, the PR FE model predictions in both elastic modulus and yield strength were highly correlated with the voxel-based FE models (r(2) = 0.99, r(2) = 0.98, respectively), resulted from the original 3D images without the PR segmentation. In conclusion, the ITS-based PR models predicted accurately both elastic modulus and yield strength determined experimentally across three distinct anatomic sites. Trabecular plates and rods accurately determine elastic modulus and yield strength of human trabecular bone.
Collapse
Affiliation(s)
- Ji Wang
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| | - Bin Zhou
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| | - X Sherry Liu
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA; McKay Orthopaedic Research Laboratory, Department of Orthopaedic Surgery, University of Pennsylvania, Philadelphia, PA, USA.
| | - Aaron J Fields
- Department of Orthopaedic Surgery, University of California San Francisco, San Francisco, CA, USA; Department of Mechanical Engineering, University of California Berkeley, Berkeley, CA, USA.
| | - Arnav Sanyal
- Department of Mechanical Engineering, University of California Berkeley, Berkeley, CA, USA.
| | - Xiutao Shi
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| | - Mark Adams
- Department of Applied Physics and Applied Mathematics, Columbia University, New York, NY, USA.
| | - Tony M Keaveny
- Department of Mechanical Engineering, University of California Berkeley, Berkeley, CA, USA.
| | - X Edward Guo
- Bone Bioengineering Laboratory, Department of Biomedical Engineering, Columbia University, New York, NY, USA.
| |
Collapse
|
23
|
Altman AR, de Bakker CMJ, Tseng WJ, Chandra A, Qin L, Liu XS. Enhanced individual trabecular repair and its mechanical implications in parathyroid hormone and alendronate treated rat tibial bone. J Biomech Eng 2014; 137:1918234. [PMID: 25321622 DOI: 10.1115/1.4028823] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/16/2014] [Accepted: 10/16/2014] [Indexed: 12/12/2022]
Abstract
Combined parathyroid hormone (PTH) and bisphosphonate (alendronate-ALN) therapy has recently been shown to increase bone volume fraction and plate-like trabecular structure beyond either monotherapy. To identify the mechanism through which plate-like structure was enhanced, we used in vivo microcomputed tomography (μCT) of the proximal tibia metaphysis and individual trabecular dynamics (ITD) analysis to quantify connectivity repair (incidences of rod connection and plate perforation filling) and deterioration (incidences of rod disconnection and plate perforation). Three-month-old female, intact rats were scanned before and after a 12 day treatment period of vehicle (Veh, n = 5), ALN (n = 6), PTH (n = 6), and combined (PTH+ALN, n = 6) therapy. Additionally, we used computational simulation and finite element (FE) analysis to delineate the contributions of connectivity repair or trabecular thickening to trabecular bone stiffness. Our results showed that the combined therapy group had greater connectivity repair (5.8 ± 0.5% connected rods and 2.0 ± 0.3% filled plates) beyond that of the Veh group, resulting in the greatest net gain in connectivity. For all treatment groups, increases in bone volume due to thickening (5-31%) were far greater than those due to connectivity repair (2-3%). Newly formed bone contributing only to trabecular thickening caused a 10%, 41%, and 69% increase in stiffness in the ALN, PTH, and PTH+ALN groups, respectively. Moreover, newly formed bone that led to connectivity repair resulted in an additional improvement in stiffness, with the highest in PTH+ALN (by an additional 12%), which was significantly greater than either PTH (5.6%) or ALN (4.5%). An efficiency ratio was calculated as the mean percent increase in stiffness divided by mean percent increase in BV for either thickening or connectivity repair in each treatment. For all treatments, the efficiency ratio of connectivity repair (ALN: 2.9; PTH: 3.4; PTH+ALN: 4.4) was higher than that due to thickening (ALN: 2.0; PTH: 1.7; PTH+ALN: 2.2), suggesting connectivity repair required less new bone formation to induce larger gains in stiffness. We conclude that through rod connection and plate perforation filling PTH+ALN combination therapy improved bone stiffness in a more efficient and effective manner than either monotherapy.
Collapse
|
24
|
Stauber M, Nazarian A, Müller R. Limitations of global morphometry in predicting trabecular bone failure. J Bone Miner Res 2014; 29:134-41. [PMID: 23761214 DOI: 10.1002/jbmr.2006] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/21/2013] [Revised: 05/10/2013] [Accepted: 06/03/2013] [Indexed: 11/07/2022]
Abstract
Efforts in finding independent measures for accurate and reliable prediction of trabecular bone failure have led to the development of a number of morphometric indices characterizing trabecular bone microstructure. Generally, these indices assume a high homogeneity within the bone specimen. However, in the present study we found that the variance in bone volume fraction (BV/TV) in a single bone specimen can be relatively large (CV = 9.07% to 28.23%). To assess the limitations of morphometric indices in the prediction of bone failure for specimens in which the assumption of homogeneity is not met, we harvested 13 cadaveric samples from a single human spine. We tested these cylindrical samples using image-guided failure assessment (IGFA), a technique combining stepwise microcompression and time-lapsed micro-computed tomography (µCT). Additionally, we computed morphometric indices for the entire sample as well as for 10 equal subregions along the anatomical axis. We found that ultimate strength was equally well predicted by BV/TV of the entire sample (R(2) = 0.55) and BV/TV of the weakest subregion (R(2) = 0.57). Investigating three-dimensional animations of structural bone failure, we showed that two main failure mechanisms determine the competence of trabecular bone samples; in homogeneous, isotropic trabecular bone samples, competence is determined by a whole set of trabecular elements, whereas in inhomogeneous, anisotropic bone samples a single or a missing trabeculae may induce catastrophic failure. The latter failure mechanism cannot be described by conventional morphometry, indicating the need for novel morphometric indices also applicable to the prediction of failure in inhomogeneous bone samples.
Collapse
Affiliation(s)
- Martin Stauber
- Institute for Biomechanics, Eidgenössische Technische Hochschule (ETH) Zurich, Zurich, Switzerland; b-cube AG, Brüttisellen, Switzerland
| | | | | |
Collapse
|
25
|
Cosmi F, Mazzoleni G. Evaluation of the structural quality of bone in a case of progressive osteoporosis complicating a Complex Regional Pain Syndrome (CRPS) of the upper limb. J Mech Behav Biomed Mater 2014; 29:517-28. [DOI: 10.1016/j.jmbbm.2013.08.006] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/11/2013] [Revised: 07/08/2013] [Accepted: 08/04/2013] [Indexed: 01/07/2023]
|
26
|
Thomsen JS, Niklassen AS, Ebbesen EN, Brüel A. Age-related changes of vertical and horizontal lumbar vertebral trabecular 3D bone microstructure is different in women and men. Bone 2013; 57:47-55. [PMID: 23899636 DOI: 10.1016/j.bone.2013.07.025] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/09/2013] [Revised: 07/15/2013] [Accepted: 07/16/2013] [Indexed: 11/28/2022]
Abstract
The study presents a 3D method for subdividing a trabecular network into horizontal and vertical oriented bone. This method was used to investigate the age related changes of the bone volume fraction and thickness of horizontal and vertical trabeculae in human lumbar vertebral bone estimated with unbiased 3D methods in women and men over a large age-range. The study comprised second lumbar vertebral body bone samples from 40 women (aged 21.7-96.4years, median 56.6years) and 39 men (aged 22.6-94.6years, median 55.6years). The bone samples were μCT scanned and the 3D microstructure was quantified. A voxel based algorithm inspecting the local neighborhood is presented and used to segment the trabecular network into horizontal and vertical oriented bone. For both women and men BV/TV decreased significantly with age, Tb.Th* was independent of age, while SMI increased significantly with age. Vertical (BV.vert/TV) and horizontal (BV.horz/TV) bone volume fraction decreased significantly with age for both sexes. BV.vert/TV decreased significantly faster with age for women than for men. Vertical (Tb.Th*.vert) and horizontal (Tb.Th*.horz) trabecular thickness were independent of age, while Tb.Th*.horz/Tb.Th*.vert decreased significantly with age for both sexes. Additionally, the 95th percentile of the trabecular thickness distribution increased significantly with age for vertical trabeculae in women, whereas it was independent of age in men. In conclusion, we have shown that vertical and horizontal oriented bone density decreases with age in both women and men, and that vertical oriented bone is lost more quickly in women than in men. Furthermore, vertical and horizontal trabecular thickness were independent of age, whereas the horizontal to vertical trabecular thickness ratio decreased significantly with age indicating a relatively more pronounced thinning of horizontal trabeculae. Finally, the age-related loss of trabecular elements appeared to result in a compensatory hypertrophy of vertical trabeculae in women, but not in men.
Collapse
|
27
|
A 3D elastic micropolar model of vertebral trabecular bone from lattice homogenization of the bone microstructure. Biomech Model Mechanobiol 2013; 13:53-83. [DOI: 10.1007/s10237-013-0486-z] [Citation(s) in RCA: 68] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2012] [Accepted: 03/16/2013] [Indexed: 10/27/2022]
|
28
|
Wang H, Sherry Liu X, Zhou B, Wang J, Ji B, Huang Y, Hwang KC, Edward Guo X. Accuracy of individual trabecula segmentation based plate and rod finite element models in idealized trabecular bone microstructure. J Biomech Eng 2013; 135:044502. [PMID: 24231904 PMCID: PMC3705952 DOI: 10.1115/1.4023983] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2012] [Revised: 01/14/2013] [Indexed: 11/08/2022]
Abstract
Currently, specimen-specific micro finite element (μFE) analysis based micro computed tomography (μCT) images have become a major computational tool for the assessment of the mechanical properties of human trabecular bone. Despite the fine characterization of the three-dimensional (3D) trabecular microstructure based on high-resolution μCT images, conventional μFE models with each voxel converted to an element are not efficient in predicting the nonlinear failure behavior of bone due to a prohibitive computational cost. Recently, a highly efficient individual trabecula segmentation (ITS)-based plate and rod (PR) modeling technique has been developed by substituting individual plates and rods with shell and beam elements, respectively. In this technical brief, the accuracy of novel PR μFE models was examined in idealized microstructure models over a broad range of trabecular thicknesses. The Young's modulus and yield strength predicted by simplified PR models strongly correlated with those of voxel models at various voxel sizes. The conversion from voxel models to PR models resulted in an ∼762-fold reduction in the largest model size and significantly accelerated the nonlinear FE analysis. The excellent predictive power of the PR μFE models, demonstrated in an idealized trabecular microstructure, provided a quantitative mechanical basis for this promising tool for an accurate and efficient assessment of trabecular bone mechanics and fracture risk.
Collapse
Affiliation(s)
- Hong Wang
- Department of Engineering Mechanics,School of Aerospace Engineering,Tsinghua University,Beijing 100084, PRCe-mail:
| | - X. Sherry Liu
- McKay Orthopaedic Research Laboratory,University of Pennsylvania,Philadelphia, PA 19104e-mail:
| | | | - Ji Wang
- e-mail: Bone Bioengineering Laboratory,Department of Biomedical Engineering,Columbia University,New York, NY 10027
| | - Baohua Ji
- Biomechanics and Biomaterials Laboratory,School of Aerospace Engineering,Beijing Institute of Technology,Beijing 100081, PRCe-mail:
| | - Yonggang Huang
- Department of Civil and Environmental Engineering,Northwestern University,Evanston, IL 60208e-mail:
| | - Keh-Chih Hwang
- Department of Engineering Mechanics,School of Aerospace Engineering,Tsinghua University,Beijing 100084, PRCe-mail:
| | - X. Edward Guo
- Bone Bioengineering Laboratory,Department of Biomedical Engineering,Columbia University,New York, NY 10027e-mail:
| |
Collapse
|
29
|
Dumont M, Laurin M, Jacques F, Pellé E, Dabin W, de Buffrénil V. Inner architecture of vertebral centra in terrestrial and aquatic mammals: A two-dimensional comparative study. J Morphol 2013; 274:570-84. [DOI: 10.1002/jmor.20122] [Citation(s) in RCA: 36] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2012] [Revised: 11/12/2012] [Accepted: 12/10/2012] [Indexed: 11/06/2022]
|
30
|
Vanderoost J, van Lenthe GH. The effect of resorption cavities on bone stiffness is site dependent. Comput Methods Biomech Biomed Engin 2013; 17:1483-91. [PMID: 23282095 DOI: 10.1080/10255842.2012.753065] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
Abstract
Resorption cavities formed during the bone remodelling cycle change the structure and thus the mechanical properties of trabecular bone. We tested the hypotheses that bone stiffness loss due to resorption cavities depends on anatomical location, and that for identical eroded bone volumes, cavities would cause more stiffness loss than homogeneous erosion. For this purpose, we used beam-shell finite element models. This new approach was validated against voxel-based FE models. We found an excellent agreement for the elastic stiffness behaviour of individual trabeculae in axial compression (R(2) = 1.00) and in bending (R(2)>0.98), as well as for entire trabecular bone samples to which resorption cavities were digitally added (R(2) = 0.96, RMSE = 5.2%). After validation, this new method was used to model discrete cavities, with dimensions taken from a statistical distribution, on a dataset of 120 trabecular bone samples from three anatomical sites (4th lumbar vertebra, femoral head, iliac crest). Resorption cavities led to significant reductions in bone stiffness. The largest stiffness loss was found for samples from the 4th lumbar vertebra, the lowest for femoral head samples. For all anatomical sites, resorption cavities caused significantly more stiffness loss than homogeneous erosion did. This novel technique can be used further to evaluate the impact of resorption cavities, which are known to change in several metabolic bone diseases and due to treatment, on bone competence.
Collapse
Affiliation(s)
- Jef Vanderoost
- a Biomechanics Section, Department of Mechanical Engineering , KU Leuven , Leuven , Belgium
| | | |
Collapse
|
31
|
Parkinson IH, Badiei A, Stauber M, Codrington J, Müller R, Fazzalari NL. Vertebral body bone strength: the contribution of individual trabecular element morphology. Osteoporos Int 2012; 23:1957-65. [PMID: 22086309 DOI: 10.1007/s00198-011-1832-6] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/14/2011] [Accepted: 08/30/2011] [Indexed: 10/15/2022]
Abstract
SUMMARY Although the amount of bone explains the largest amount of variability in bone strength, there is still a significant proportion unaccounted for. The morphology of individual bone trabeculae explains a further proportion of the variability in bone strength and bone elements that contribute to bone strength depending on the direction of loading. INTRODUCTION Micro-CT imaging enables measurement of bone microarchitecture and subsequently mechanical strength of the same sample. It is possible using micro-CT data to perform morphometric analysis on individual rod and plate bone trabeculae using a volumetric spatial decomposition algorithm and hence determine their contribution to bone strength. METHODS Twelve pairs of vertebral bodies (T12/L1 or L4/L5) were harvested from human cadavers, and bone cubes (10 × 10 × 10 mm) were obtained. After micro-CT imaging, a volumetric spatial decomposition algorithm was applied, and measures of individual trabecular elements were obtained. Bone strength was measured in compression, where one bone specimen from each vertebral segment was tested supero-inferiorly (SI) and the paired specimen was tested antero-posteriorly (AP). RESULTS Bone volume fraction was the strongest individual determinant of SI strength (r(2) = 0.77, p < 0.0001) and AP (r(2) = 0.54, p < 0.0001). The determination of SI strength was improved to r(2) = 0.87 with the addition of mean rod length and relative plate bone volume fraction. The determination of AP strength was improved to r(2) = 0.85 with the addition of mean rod volume and relative rod bone volume fraction. CONCLUSIONS Microarchitectural measures of individual trabeculae that contribute to bone strength have been identified. In addition to the contribution of BV/TV, trabecular rod morphology increased the determination of AP strength by 57%, whereas measures of trabecular plate and rod morphology increased determination of SI strength by 13%. Decomposing vertebral body bone architecture into its constituent morphological elements shows that trabecular element morphology has specific functional roles to assist in maintaining skeletal integrity.
Collapse
Affiliation(s)
- I H Parkinson
- Bone and Joint Research Laboratory, SA Pathology and Hanson Institute, Frome Road, Adelaide, South Australia, 5000, Australia.
| | | | | | | | | | | |
Collapse
|
32
|
Liu XS, Ardeshirpour L, VanHouten JN, Shane E, Wysolmerski JJ. Site-specific changes in bone microarchitecture, mineralization, and stiffness during lactation and after weaning in mice. J Bone Miner Res 2012; 27:865-75. [PMID: 22189918 DOI: 10.1002/jbmr.1503] [Citation(s) in RCA: 63] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Despite the dramatic bone loss that occurs during lactation, bone mineral density rapidly recovers after offspring are weaned and milk production stops. The goal of this study is to quantify site-specific changes in bone quantity and quality during and after lactation in a mouse model. We used micro computed tomography (µCT), individual trabecula segmentation (ITS), digital topological analysis (DTA)-based tissue mineral density (TMD) analysis, and micro finite element analysis (µFEA) to quantify the effects of lactation and weaning on bone microarchitecture, mineralization, and stiffness at the spine, tibia, and femur. We found a significant decrease in trabecular plate microarchitecture, tissue mineralization of the trabecular surface, trabecular central skeleton, and intervening envelopes, and whole bone stiffness in lactating versus nulliparous mice at all three sites. In recovered mice, all these different aspects of bone quality were comparable to nulliparous mice at the spine. In contrast, trabecular plate microarchitecture and whole bone stiffness at the tibia and femur in recovered mice were lower than nulliparous mice, as were central trabecular tissue mineralization and cortical structure at the femur. These findings are consistent with clinical observations of partial recovery of femoral bone mineral density BMD after lactation in humans. The observed differences in trabecular surface tissue mineralization in nulliparous, lactating, and recovered mice are consistent with prior observations that maternal bone turnover shifts from resorption to formation at the time of pup weaning. The significant differences in trabecular central tissue mineralization during these three states suggest that osteocytes may contribute to the reversible loss of mineral during and after lactation. Future studies are necessary to determine whether differing functions of various bone cells at individual skeletal sites cause site-specific skeletal changes during and after lactation.
Collapse
Affiliation(s)
- X Sherry Liu
- Division of Endocrinology, Department of Medicine, College of Physicians and Surgeons, Columbia University, New York, NY, USA.
| | | | | | | | | |
Collapse
|
33
|
Garrison JG, Gargac JA, Niebur GL. Shear strength and toughness of trabecular bone are more sensitive to density than damage. J Biomech 2011; 44:2747-54. [PMID: 21945570 DOI: 10.1016/j.jbiomech.2011.09.002] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2011] [Revised: 09/02/2011] [Accepted: 09/05/2011] [Indexed: 11/25/2022]
Abstract
Microdamage occurs in trabecular bone under normal loading, which impairs the mechanical properties. Architectural degradation associated with osteoporosis increases damage susceptibility, resulting in a cumulative negative effect on the mechanical properties. Treatments for osteoporosis could be targeted toward increased bone mineral density, improved architecture, or repair and prevention of microdamage. Delineating the relative roles of damage and architectural degradation on trabecular bone strength will provide insight into the most beneficial targets. In this study, damage was induced in bovine trabecular bone samples by axial compression, and the effects on the mechanical properties in shear were assessed. The damaged shear modulus, shear yield stress, ultimate shear stress, and energy to failure all depended on induced damage and decreased as the architecture became more rod-like. The changes in ultimate shear strength and toughness were proportional to the decrease in shear modulus, consistent with an effective decrease in the cross-section of trabeculae based on cellular solid analysis. For typical ranges of bone volume fraction in human bone, the strength and toughness were much more sensitive to decreased volume fraction than to induced mechanical damage. While ultimately repairing or avoiding damage to the bone structure and increasing bone density both improve mechanical properties, increasing bone density is the more important contributor to bone strength.
Collapse
Affiliation(s)
- Jacqueline G Garrison
- Tissue Mechanics Laboratory, Bioengineering Graduate Program and Department of Aerospace and Mechanical Engineering, University of Notre Dame, 147 Multidisciplinary Research, Notre Dame, IN 46556, USA
| | | | | |
Collapse
|
34
|
Liu XS, Shane E, McMahon DJ, Guo XE. Individual trabecula segmentation (ITS)-based morphological analysis of microscale images of human tibial trabecular bone at limited spatial resolution. J Bone Miner Res 2011; 26:2184-93. [PMID: 21557311 DOI: 10.1002/jbmr.420] [Citation(s) in RCA: 51] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Individual trabecula segmentation (ITS), a rigorous model-independent 3D morphological analysis, has been developed to assess trabecular plate and rod microstructure separately based on micro-computed tomographic (µCT) images. We examined the influence of the limited spatial resolution, noise, and artifact of high-resolution peripheral quantitative CT (HR-pQCT) on ITS measurements of human tibial trabecular bone. In comparison with measurements from "gold standard" µCT images (25 µm), decreased spatial resolution (40, 60, and 80 µm) of µCT had minimal influence on the correlations of the scale of trabecular plates (ie, plate bone volume fraction, thickness, and surface area) and the orientation (ie, axial bone volume fraction) and structural type (ie, plate tissue fraction) of the trabecular network. ITS measurements of HR-pQCT images correlated significantly with those of µCT images at a similar voxel size (80 µm, r = 0.71-0.94); correlations were stronger for plate-related parameters, suggesting that measurements of trabecular rods are more subject to noise and artifact associated with HR-pQCT imaging technology. In comparison with measurements of "gold standard" µCT images, the percent absolute errors of HR-pQCT measurements such as axial and plate bone volume fraction, plate number and tissue fraction, and plate and rod thickness (3.5% to 10.3%) were comparable with those of bone volume fraction (9.3%). For both HR-pQCT and µCT images, measurements of the scale and junction densities of trabecular plates and orientation and structural type were strong and positive indicators of the elastic modulus of trabecular bone (r = 0.59-0.95). We conclude that ITS measurements of HR-pQCT images are highly reflective of trabecular bone microarchitecture from a biomechanical perspective.
Collapse
Affiliation(s)
- X Sherry Liu
- Division of Endocrinology, Department of Medicine, Columbia University, New York, NY 10027, USA
| | | | | | | |
Collapse
|
35
|
Relationship between architectural parameters and sample volume of human cancellous bone in micro-CT scanning. Med Eng Phys 2011; 33:764-9. [DOI: 10.1016/j.medengphy.2011.01.014] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/11/2010] [Revised: 01/27/2011] [Accepted: 01/27/2011] [Indexed: 11/18/2022]
|
36
|
Ruffoni D, Müller R, van Lenthe GH. Mechanisms of reduced implant stability in osteoporotic bone. Biomech Model Mechanobiol 2011; 11:313-23. [DOI: 10.1007/s10237-011-0312-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2010] [Accepted: 04/26/2011] [Indexed: 10/18/2022]
|
37
|
Alwood JS, Yumoto K, Mojarrab R, Limoli CL, Almeida EAC, Searby ND, Globus RK. Heavy ion irradiation and unloading effects on mouse lumbar vertebral microarchitecture, mechanical properties and tissue stresses. Bone 2010; 47:248-55. [PMID: 20466089 DOI: 10.1016/j.bone.2010.05.004] [Citation(s) in RCA: 55] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/07/2010] [Revised: 05/03/2010] [Accepted: 05/04/2010] [Indexed: 11/18/2022]
Abstract
Astronauts are exposed to both musculoskeletal disuse and heavy ion radiation in space. Disuse alters the magnitude and direction of forces placed upon the skeleton causing bone remodeling, while energy deposited by ionizing radiation causes free radical formation and can lead to DNA strand breaks and oxidative damage to tissues. Radiation and disuse each result in a net loss of mineralized tissue in the adult, although the combined effects, subsequent consequences for mechanical properties and potential for recovery may differ. First, we examined how a high dose (2 Gy) of heavy ion radiation ((56)Fe) causes loss of mineralized tissue in the lumbar vertebrae of skeletally mature (4 months old), male, C57BL/6 mice using microcomputed tomography and determined the influence of structural changes on mechanical properties using whole bone compression tests and finite element analyses. Next, we tested if a low dose (0.5 Gy) of heavy particle radiation prevents skeletal recovery from a 14-day period of hindlimb unloading. Irradiation with a high dose of (56)Fe (2 Gy) caused bone loss (-14%) in the cancellous-rich centrum of the fourth lumbar vertebra (L4) 1 month later, increased trabecular stresses (+27%), increased the propensity for trabecular buckling and shifted stresses to the cortex. As expected, hindlimb unloading (14 days) alone adversely affected microarchitectural and mechanical stiffness of lumbar vertebrae, although the reduction in yield force was not statistically significant (-17%). Irradiation with a low dose of (56)Fe (0.5 Gy) did not affect vertebrae in normally loaded mice, but significantly reduced compressive yield force in vertebrae of unloaded mice relative to sham-irradiated controls (-24%). Irradiation did not impair the recovery of trabecular bone volume fraction that occurs after hindlimb unloaded mice are released to ambulate normally, although microarchitectural differences persisted 28 days later (96% increase in ratio of rod- to plate-like trabeculae). In summary, (56)Fe irradiation (0.5 Gy) of unloaded mice contributed to a reduction in compressive strength and partially prevented recovery of cancellous microarchitecture from adaptive responses of lumbar vertebrae to skeletal unloading. Thus, irradiation with heavy ions may accelerate or worsen the loss of skeletal integrity triggered by musculoskeletal disuse.
Collapse
Affiliation(s)
- J S Alwood
- Department of Aeronautics and Astronautics, 496 Lomita Mall, Stanford University, Stanford, CA 94305, USA.
| | | | | | | | | | | | | |
Collapse
|
38
|
Rantalainen T, Nikander R, Heinonen A, Multanen J, Häkkinen A, Jämsä T, Kiviranta I, Linnamo V, Komi PV, Sievänen H. Neuromuscular performance and body mass as indices of bone loading in premenopausal and postmenopausal women. Bone 2010; 46:964-9. [PMID: 20064632 DOI: 10.1016/j.bone.2010.01.002] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/12/2009] [Revised: 12/22/2009] [Accepted: 01/05/2010] [Indexed: 12/31/2022]
Abstract
The strong association between body mass and skeletal robusticity has been attributed to increasing skeletal loading with increasing mass. However, it is unclear whether body mass is merely a coarse substitute for bone loading rather than a true independent predictor of bone strength. As indices of neuromuscular performance, impulse and peak power were determined from vertical ground reaction force during a maximal counter movement jump test in 221 premenopausal and 82 postmenopausal women. Bone compressive (BSI(d) g(2)/cm(4)) and bending (SSImax(mid) mm(3)) strength indices were measured with peripheral quantitative computed tomography (pQCT) at the distal ((d)) and midshaft ((mid)) sites of the tibia. A two-step forced regression model for predicting bone strength indices was constructed. Age, height and body mass were entered first, followed by impulse as an indicator of skeletal loading. The basic model explained 14% (P<0.001) of the variance in BSI(d) in the premenopausal group and 16% (P=0.004) in the postmenopausal group, and 32% (P<0.001) and 25% (P<0.001) of the variance in SSImax(nud) respectively. Entering impulse into the model increased the explanatory power by 9% (P<0.001) and 7% (P<0.001) for BSI(d) and by 8% (P<0.001) and 12% (P<0.001) for SSImax(mid). Furthermore, impulse replaced body mass as an independent significant factor explaining the variance in bone strength. These results indicate that neuromuscular performance should be measured and preferred over body mass in models predicting skeletal robusticity.
Collapse
Affiliation(s)
- Timo Rantalainen
- Department of Biology of Physical Activity, University of Jyväskylä, Finland.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
39
|
Parkinson IH, Forbes D, Sutton-Smith P, Fazzalari NL. Model-Independent 3D Descriptors of Vertebral Cancellous Bone Architecture. J Osteoporos 2009; 2010:641578. [PMID: 20975775 PMCID: PMC2957160 DOI: 10.4061/2010/641578] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/26/2009] [Revised: 09/07/2009] [Accepted: 10/13/2009] [Indexed: 11/20/2022] Open
Abstract
High-resolution micro computed tomography has enabled measurement of bone architecture derived from 3D representations of cancellous bone. Twenty-eight vertebral bodies were obtained from four embalmed male cadavers. From 3D anaglyphs, trabecular rod thickness and length were measured and the trabecular rod Buckling index was calculated. From 3D voxel-based datasets, bone volume density, trabecular thickness, and trabecular separation were measured. Also, trabecular bone pattern factor, structural model index, connectivity density, and degree of anisotropy were calculated. Bone volume density alone explains 59% of the variability in trabecular rod Buckling index. The addition of connectivity density, trabecular separation, and structural model index, in a multiple regression statistical model, improves the explanatory power to 77%. The relationships between measures of cancellous bone architecture and a derived measure of trabecular rod strength were investigated. Morphological descriptors of cancellous bone provide a composite explanatory model of trabecular rod strength.
Collapse
Affiliation(s)
- Ian H. Parkinson
- Bone and Joint Research Laboratory, SA Pathology and Hanson Institute, Discipline of Pathology, University of Adelaide, Adelaide, South Australia 5000, Australia,*Ian H. Parkinson:
| | - Danielle Forbes
- Bone and Joint Research Laboratory, SA Pathology and Hanson Institute, Discipline of Pathology, University of Adelaide, Adelaide, South Australia 5000, Australia
| | - Peter Sutton-Smith
- Bone and Joint Research Laboratory, SA Pathology and Hanson Institute, Discipline of Pathology, University of Adelaide, Adelaide, South Australia 5000, Australia
| | - Nicola L. Fazzalari
- Bone and Joint Research Laboratory, SA Pathology and Hanson Institute, Discipline of Pathology, University of Adelaide, Adelaide, South Australia 5000, Australia
| |
Collapse
|
40
|
Rantalainen T, Sievänen H, Linnamo V, Hoffrén M, Ishikawa M, Kyröläinen H, Avela J, Selänne H, Komi PV, Heinonen A. Bone rigidity to neuromuscular performance ratio in young and elderly men. Bone 2009; 45:956-63. [PMID: 19631780 DOI: 10.1016/j.bone.2009.07.014] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/23/2009] [Revised: 06/23/2009] [Accepted: 07/15/2009] [Indexed: 11/15/2022]
Abstract
Given the adaptation of bone to prevalent loading, bone loss should follow, but lag behind, the decline in physical performance during aging. Furthermore, bone responsiveness to load-induced strains is believed to decrease with aging. However, the relationship between bone and lean body ( approximately muscle) mass appears to remain rather constant throughout adulthood. The purpose of this study was to examine the association between age and bone to neuromuscular performance ratio. Young (N=20, age 24 SD+/-2 years, body mass 77+/-11 kg, height 178+/-6 cm) and elderly (N=25, 72+/-4 years, 75+/-9 kg, 172+/-5 cm) men served as subjects. Bone structural traits were measured at the right distal tibia and tibial mid-shaft with peripheral quantitative computed tomography (pQCT). Maximal section modulus (Z(max50)), total area (ToA(d)), cortical area (CoA(50)), total density (ToD(d)) and cortical density (CoD(50)) were determined from the pQCT images. Neuromuscular performance was measured by recording vertical ground reaction force (GRF) in maximal bilateral hopping. Load-induced strains were estimated by calculating appropriate indices for compressive and tensile loading that took into account both the bone structure and apparent biomechanics of the given bone site. Young subjects had significantly higher maximal GRF compared to older men (4260+/-800 N vs. 3080+/-600 N, P<0.001). They also had smaller ToA(d) (1100+/-170 mm(2) vs. 1200+/-100 mm(2), P=0.028) while their ToD(d) was higher (370+/-46 g/cm(3) vs. 330+/-22 g/cm(3), P=0.002). The Z(max50) did not differ significantly between young (1660+/-320 mm(3)) and elderly men (1750+/-320 mm(3)) (P=0.224). Compressive (0.484+/-0.102 vs. 0.399+/-0.078, P=0.016) and tensile (0.107+/-0.016 vs. 0.071+/-0.018, P<0.001) strain indices were significantly higher in the younger group. In conclusion, the difference in bone to loading ratio at the tibial mid-shaft is bigger than expected from the delay in bone adaptation alone. Potential candidates to explain this phenomenon include a decrease in mechanosensitivity with aging, inability of maximal physical performance to adequately represent the bone loading environment, or the need to maintain constant safety factors to functional strains.
Collapse
Affiliation(s)
- T Rantalainen
- Neuromuscular Research Centre, Department of Biology of Physical Activity, University of Jyväskylä, Finland.
| | | | | | | | | | | | | | | | | | | |
Collapse
|