1
|
Sun R, Yin Z, Stevens MM, Li M, Mann S. Cytomimetic calcification in chemically self-regulated prototissues. Nat Commun 2025; 16:4138. [PMID: 40319022 PMCID: PMC12049547 DOI: 10.1038/s41467-025-59251-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2024] [Accepted: 04/16/2025] [Indexed: 05/07/2025] Open
Abstract
The fabrication of cytomimetic materials capable of orchestrated and adaptive functions remains a significant challenge in bottom-up synthetic biology. Inspired by the cell/matrix integration of living bone, here we covalently tether distributed single populations of alkaline phosphatase-containing inorganic protocells (colloidosomes) onto a crosslinked organic network to establish viscoelastic tissue-like micro-composites. The prototissues are endogenously calcified with site-specific mineralization modalities involving selective intra-protocellular calcification, matrix-specific extra-protocellular calcification or gradient calcification. To mirror the interplay between osteoblasts and osteoclasts, we prepare integrated prototissues comprising a binary population of enzymatically active colloidosomes capable of endogenous calcification and decalcification and utilize chemical inputs to induce structural remodelling. Overall, our methodology opens a route to the chemically self-regulated calcification of homogeneous and gradient tissue-like mineral-matrix composites, advances the development of bottom-up synthetic biology in chemical materials research, and could provide potential opportunities in bioinspired tissue engineering, hydrogel technologies and bone biomimetics.
Collapse
Affiliation(s)
- Rui Sun
- Centre for Protolife Research and Centre for Organized Matter Chemistry, School of Chemistry, University of Bristol, Bristol, UK
- Department of Medical Biochemistry and Biophysics, Karolinska Institute, Stockholm, Sweden
| | - Zhuping Yin
- Centre for Protolife Research and Centre for Organized Matter Chemistry, School of Chemistry, University of Bristol, Bristol, UK
| | - Molly M Stevens
- Department of Medical Biochemistry and Biophysics, Karolinska Institute, Stockholm, Sweden
- Department of Physiology, Anatomy and Genetics, Department of Engineering Science, Kavli Institute for Nanoscience Discovery, University of Oxford, Oxford, UK
| | - Mei Li
- Centre for Protolife Research and Centre for Organized Matter Chemistry, School of Chemistry, University of Bristol, Bristol, UK.
| | - Stephen Mann
- Centre for Protolife Research and Centre for Organized Matter Chemistry, School of Chemistry, University of Bristol, Bristol, UK.
- Max Planck-Bristol Centre for Minimal Biology, School of Chemistry, University of Bristol, Bristol, UK.
| |
Collapse
|
2
|
García-Vilana S, Sánchez-Molina D. Statistical mechanics of bone damage: a constitutive model. EUROPEAN BIOPHYSICS JOURNAL : EBJ 2025; 54:185-200. [PMID: 40317307 DOI: 10.1007/s00249-025-01749-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2024] [Revised: 03/28/2025] [Accepted: 04/06/2025] [Indexed: 05/07/2025]
Abstract
After the elastic regime is surpassed, cortical bone exhibits significant microcracking in its post-elastic mechanical behavior. This work develops a thermodynamically consistent, nonlinear constitutive model based on statistical mechanics, designed to predict the stress-strain relationship and the progression of inter-osteon microcracking. To assess the model's sufficiency, precise tensile and bending tests were performed in comparison to empirical curves that illustrated theoretical predictions of constitutive relationships. Moreover, entropy increases were quantitatively assessed using model parameters refined through experimental data. A large-size sample was utilized, comprising 51 dog-bone-shaped cortical bone specimens from the 4th ribs of various subjects for uniaxial tensile tests, and 15 complete fourth ribs for bending tests. Displacement and strain fields were meticulously recorded using digital image correlation and video analysis. The model demonstrated robustness, accurately fitting the data from all experimental specimens and revealing correlations between constitutive parameters and anthropometric variables. Entropy calculations provide insights into the behavior of the bone under varying strains: microcracking is minimal at low strains with stress nearly proportional to strain, escalating significantly beyond a critical threshold, thus challenging the linear relationship between stress and strain.
Collapse
Affiliation(s)
- S García-Vilana
- UPC, EEBE-GIES, Eduard Maristany, 14, 08019, Barcelona, Spain
| | | |
Collapse
|
3
|
Bavil AY, Eghan-Acquah E, Diamond LE, Barrett R, Bade D, Carty CP, Feih S, Saxby DJ. Effect of Postoperative Neck-Shaft and Anteversion Angles on Biomechanical Outcomes in Proximal Femoral Osteotomy: An In Silico Study. J Orthop Res 2025; 43:842-852. [PMID: 39810480 DOI: 10.1002/jor.26043] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/30/2024] [Revised: 11/27/2024] [Accepted: 12/24/2024] [Indexed: 01/16/2025]
Abstract
Effective surgical planning is crucial for maximizing patient outcomes following complex orthopedic procedures such as proximal femoral osteotomy. In silico simulations can be used to assess how surgical variations in proximal femur geometry, such as femur neck-shaft and anteversion angles, affect postoperative system mechanics. This study investigated the sensitivity of femur mechanics to postoperative neck-shaft angles, anteversion angles, and osteotomy contact areas using patient-specific finite element analysis informed by neuromusculoskeletal models. A sequential neuromusculoskeletal modeling and finite element analysis pipeline was used to simulate postoperative mechanics in three pediatric patients with varying demographic and anatomic features. Nine surgical configurations derived from permutations of the clinical envelope of neck-shaft angles and anteversion angles were simulated for the stance phase of gait. The outcome mechanics assessed were peak von Mises stresses on the bone-implant contact surfaces as well as interfragmentary movement and strain on the osteotomy location. Peak von Mises stress and interfragmentary movement and strain were on average 38% more sensitive to surgical variation in neck-shaft angle compared to anteversion angle. A significant negative correlation was detected between contact area and interfragmentary movement (r = -0.90, p < 0.0001) and strain (r = -0.45, p = 0.017). Overall findings suggest neck-shaft angle significantly influences postoperative femur mechanics and highlight the importance of maximizing contact area to limit interfragmentary motion and foster an optimal mechanical environment for bone healing and callus formation following proximal femoral osteotomy. Between-patient variation in sensitivity to proximal femoral geometry reinforced the importance of patient-specific surgical planning.
Collapse
Affiliation(s)
- Alireza Y Bavil
- Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Emmanuel Eghan-Acquah
- Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Laura E Diamond
- Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
| | - Rod Barrett
- Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
| | - David Bade
- Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Gold Coast, Australia
- Department of Orthopaedics, Children's Health Queensland Hospital and Health Service, South Brisbane, Australia
| | - Christopher P Carty
- Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
- Department of Orthopaedics, Children's Health Queensland Hospital and Health Service, South Brisbane, Australia
- School of Medicine and Dentistry, Griffith University, Gold Coast, Australia
| | - Stefanie Feih
- Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
- School of Engineering and Build Environment, Griffith University, Gold Coast, Australia
| | - David J Saxby
- Australian Centre for Precision Health and Technology (PRECISE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
| |
Collapse
|
4
|
Xu Y, Brüling J, Carman L, Yeung T, Besier TF, Choisne J. A statistical shape and density model can accurately predict bone morphology and regional femoral bone mineral density variation in children. Bone 2025; 193:117419. [PMID: 39892636 DOI: 10.1016/j.bone.2025.117419] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/08/2024] [Revised: 01/22/2025] [Accepted: 01/29/2025] [Indexed: 02/04/2025]
Abstract
Finite element analysis (FEA) is a widely used tool to predict bone biomechanics in orthopaedics for prevention, treatment, and implant design. Subject-specific FEA models are more accurate than generic adult-scaled models, especially for a paediatric population, due to significant differences in bone geometry and bone mineral density. However, creating these models can be time-consuming, costly and requires medical imaging. To address these limitations, population-based models have been successful in characterizing bone shape and density variation in adults. However, children are not small adults and need their own population-based model to generate accurate and accessible musculoskeletal geometry and bone mineral density in a paediatric population. Therefore, this study aimed to create a biomechanical research tool to predict the personalized shape and density of the paediatric femur using a statistical shape and density model for a population of children aged from 4 to 18 years old. Femur morphology and bone mineral density were extracted from 330 CT scans of children. Variations in shape and density were captured using Principal Component Analysis (PCA). Principal components were correlated to demographic and linear bone measurements to create a predictive statistical shape-density model, which was used to predict femoral shape and density. A leave-one-out analysis showed that the shape-density model can predict the femur geometry with a root mean square error (RMSE) of 1.78 ± 0.46 mm and the bone mineral density with a normalized RMSE ranging from 8.9 % to 13.5 % across various femoral regions. These results underscore the model's potential to reflect real-world physiological variations in the paediatric femur. This statistical shape and density model has the potential for clinical application in rapidly generating personalized computational models using partial or no medical imaging data.
Collapse
Affiliation(s)
- Yidan Xu
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Jannes Brüling
- Department of Engineering Science and Biomedical Engineering, The University of Auckland, Auckland, New Zealand
| | - Laura Carman
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Ted Yeung
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand
| | - Thor F Besier
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand; Department of Engineering Science and Biomedical Engineering, The University of Auckland, Auckland, New Zealand
| | - Julie Choisne
- Auckland Bioengineering Institute, The University of Auckland, Auckland, New Zealand.
| |
Collapse
|
5
|
di Laura Frattura G, Cochard B, De Marco G, Vazquez O, Dayer R, Ceroni D. Femoral fractures in non-accidental trauma and child abuse: biomechanical perspective and insights. Front Pediatr 2025; 13:1484920. [PMID: 40070603 PMCID: PMC11893828 DOI: 10.3389/fped.2025.1484920] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/22/2024] [Accepted: 02/03/2025] [Indexed: 03/14/2025] Open
Abstract
Physical abuse remains a global problem that affects children in every country, from every ethnic group, and of all social backgrounds. The fracture of an infant's femur should constitute a red flag to a pediatrician; it must be recognized, recorded, investigated, and potentially result in measures to protect that child. Certain confounding factors, such as the reported mechanism of trauma, could negatively influence the physician's appropriate and unbiased judgment. Indeed, some physically abusive parents may try to explain a femoral fracture as the result of an accidental fall from a changing table or the child's leg getting stuck in bed barriers. This narrative review aimed to provide an overview of this topic and discuss the currently available scientific evidence to better understand the biomechanical mechanisms of femur fractures in infants, thereby definitively putting an end to some popular misconceptions.
Collapse
Affiliation(s)
- Giorgio di Laura Frattura
- Pediatric Orthopedics Unit, Pediatric Surgery Service, University Hospitals of Geneva, Genève, Switzerland
| | - Blaise Cochard
- Pediatric Orthopedics Unit, Pediatric Surgery Service, University Hospitals of Geneva, Genève, Switzerland
| | - Giacomo De Marco
- Pediatric Orthopedics Unit, Pediatric Surgery Service, University Hospitals of Geneva, Genève, Switzerland
| | - Oscar Vazquez
- Pediatric Orthopedics Unit, Pediatric Surgery Service, University Hospitals of Geneva, Genève, Switzerland
- Division of Orthopedics and Trauma Surgery, Geneva University Hospitals, Geneva, Switzerland
| | - Romain Dayer
- Pediatric Orthopedics Unit, Pediatric Surgery Service, University Hospitals of Geneva, Genève, Switzerland
| | - Dimitri Ceroni
- Pediatric Orthopedics Unit, Pediatric Surgery Service, University Hospitals of Geneva, Genève, Switzerland
| |
Collapse
|
6
|
Kalsi S, Singh J, Saini KV, Sharma NK. Orientation effect and locational variation in elastic-plastic compressive properties of bovine cortical bone. Proc Inst Mech Eng H 2025; 239:72-82. [PMID: 39785362 DOI: 10.1177/09544119241308056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/12/2025]
Abstract
Bone is a highly heterogeneous and anisotropic material with a hierarchical structure. The effect of diaphysis locations and directions of loading on elastic-plastic compressive properties of bovine femoral cortical bone was examined in this study. The impact of location and loading directions on elastic-plastic compressive properties of cortical bone was found to be statistically insignificant in this study. The variances of most of the compressive properties were also observed to be location and directionality independent except for the locational differences in modulus of resilience (distal to central for longitudinal loading) and plastic work (central to distal for transverse loading) as well as differences in variances of the modulus of resilience and elastic modulus values for two directions of loading. The micro-mechanisms of cortical bone failure for longitudinal and transverse directions of loading were considered to be responsible for the difference in variances in the later properties values as well as for the maximum and minimum coefficient of variation (CV) obtained for compressive properties in two directions of loading. The representative cubical volume at the tested hierarchical level contained all unique microstructural features of the plexiform bone and therefore produced the homogeneous and isotropic elastic-plastic compressive properties of cortical bone. It is expected that the outcome of this study may be helpful in the area of bone tissue engineering and finite element simulation of cortical bone.
Collapse
Affiliation(s)
- Sachin Kalsi
- Department of Mechanical Engineering, Chandigarh University, Mohali, Punjab, India
| | - Jagjit Singh
- Department of Mechanical Engineering, Chandigarh University, Mohali, Punjab, India
| | - Karan Vir Saini
- Department of Chemical and Biomolecular Engineering, University of Pennsylvania, Philadelphia, PA, USA
| | - Nitin Kumar Sharma
- Department of Mechanical Engineering, Chandigarh University, Mohali, Punjab, India
- Department of Mechanical Engineering, University of Saskatchewan, Saskatoon, SK, Canada
| |
Collapse
|
7
|
Lu YH, Tai CL, Lee WC, Wang SY, Mao CY, Yang WE, Chang CH, Kao HK. Biomechanical assessment of Kirschner wires integrated with a novel external fixation device for treatment of pediatric supracondylar humeral fracture: a finite element analysis. Front Bioeng Biotechnol 2024; 12:1480298. [PMID: 39703794 PMCID: PMC11655205 DOI: 10.3389/fbioe.2024.1480298] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2024] [Accepted: 11/25/2024] [Indexed: 12/21/2024] Open
Abstract
Background Pediatric supracondylar humeral fractures present considerable surgical challenges due to the difficulty of achieving proper fracture alignment and stable fixation while avoiding injury to the ulnar nerve. This study assesses the biomechanical performance of a novel Kirschner wire (K-wire) fixation device (KFD), designed to enhance stability and reduce complications linked to traditional K-wire configurations. Methods Using finite element analysis (FEA), we evaluated four fixation strategies for treatment of pediatric supracondylar humeral simple transverse fractures: crossed pin fixation, crossed pin fixation with KFD, two lateral pin fixation, and two lateral pin fixation with KFD, under various mechanical loads. The analysis focused on the stress and strain experienced by the K-wires at the fracture site during torsional and bending forces. Results FEA revealed that the KFD significantly reduced the stress and strain on the K-wires in all configurations. In both crossed pin and two lateral pin fixation methods, the addition of the KFD showed lower stress and strain levels compared to setups without the KFD. Conclusion This study demonstrates the potential of the KFD to enhance fracture stability and reduce mechanical stress at the fracture site, suggesting a promising improvement in the treatment of pediatric supracondylar humeral fractures. This innovation may contribute to safer and more reliable outcomes in pediatric orthopedic surgery.
Collapse
Affiliation(s)
- Yu-Hsin Lu
- Department of General Medicine, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
| | - Ching-Lung Tai
- Department of Biomedical Engineering, Chang Gung University, Taoyuan, Taiwan
- Bone and Joint Research Center, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
| | - Wei-Chun Lee
- Bone and Joint Research Center, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
- Division of Pediatric Orthopaedics, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
| | - Si-Yao Wang
- Bone and Joint Research Center, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
- Division of Pediatric Orthopaedics, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
| | - Chi-Yu Mao
- Department of Biomedical Engineering, Chang Gung University, Taoyuan, Taiwan
| | - Wen-E. Yang
- Bone and Joint Research Center, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
- Division of Pediatric Orthopaedics, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
| | - Chia-Hsieh Chang
- Bone and Joint Research Center, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
- Division of Pediatric Orthopaedics, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
| | - Hsuan-Kai Kao
- Bone and Joint Research Center, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
- Division of Pediatric Orthopaedics, Department of Orthopaedic Surgery, Chang Gung Memorial Hospital at Linkou, Taoyuan, Taiwan
- College of Medicine, Chang Gung University, Taoyuan, Taiwan
| |
Collapse
|
8
|
Wong I, Zhang Z, Dang X, Yu X, Lin X, Li Y, Deng F, Xu R. Single missing molar with wide mesiodistal length restored using a single or double implant-supported crown: A self-controlled case report and 3D finite element analysis. J Prosthodont Res 2024; 68:658-666. [PMID: 38644231 DOI: 10.2186/jpr.jpr_d_23_00278] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/23/2024]
Abstract
PURPOSE Based on a self-controlled case, this study evaluated the finite element analysis (FEA) results of a single missing molar with wide mesiodistal length (MDL) restored by a single or double implant-supported crown. METHODS A case of a missing bilateral mandibular first molar with wide MDL was restored using a single or double implant-supported crown. The implant survival and peri-implant bone were compared. FEA was conducted in coordination with the case using eight models with different MDLs (12, 13, 14, and 15 mm). Von Mises stress was calculated in the FEA to evaluate the biomechanical responses of the implants under increasing vertical and lateral loading, including the stress values of the implant, abutment, screw, crown, and cortical bone. RESULTS The restorations on the left and right sides supported by double implants have been used for 6 and 12 years, respectively, and so far have shown excellent osseointegration radiographically.The von Mises stress calculated in the FEA showed that when the MDL was >14 mm, both the bone and prosthetic components bore more stress in the single implant-supported strategy. The strength was 188.62-201.37 MPa and 201.85-215.9 MPa when the MDL was 14 mm and 15 mm, respectively, which significantly exceeded the allowable yield stress (180 MPa). CONCLUSIONS Compared with the single implant-supported crown, the double implant-supported crown reduced peri-implant bone stress and produced a more appropriate stress transfer model at the implant-bone interface when the MDL of the single missing molar was ≥14 mm.
Collapse
Affiliation(s)
- Iohong Wong
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Zhengchuan Zhang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Xiaobing Dang
- Guangdong Janus Biotechnology Co., Ltd., Guangzhou, China
- Guangdong CAS Angels Biotechnology Co., Ltd., Foshan, China
| | - Xiaoran Yu
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Xiaoxuan Lin
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Yiming Li
- Department of Stomatology, the Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, China
| | - Feilong Deng
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| | - Ruogu Xu
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, China
| |
Collapse
|
9
|
Bavil AY, Eghan-Acquah E, Diamond LE, Barrett R, Carty CP, Barzan M, Nasseri A, Lloyd DG, Saxby DJ, Feih S. Effect of different constraining boundary conditions on simulated femoral stresses and strains during gait. Sci Rep 2024; 14:10808. [PMID: 38734763 PMCID: PMC11088641 DOI: 10.1038/s41598-024-61305-x] [Citation(s) in RCA: 8] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Accepted: 05/03/2024] [Indexed: 05/13/2024] Open
Abstract
Finite element analysis (FEA) is commonly used in orthopaedic research to estimate localised tissue stresses and strains. A variety of boundary conditions have been proposed for isolated femur analysis, but it remains unclear how these assumed constraints influence FEA predictions of bone biomechanics. This study compared the femoral head deflection (FHD), stresses, and strains elicited under four commonly used boundary conditions (fixed knee, mid-shaft constraint, springs, and isostatic methods) and benchmarked these mechanics against the gold standard inertia relief method for normal and pathological femurs (extreme anteversion and retroversion, coxa vara, and coxa valga). Simulations were performed for the stance phase of walking with the applied femoral loading determined from patient-specific neuromusculoskeletal models. Due to unrealistic biomechanics observed for the commonly used boundary conditions, we propose a novel biomechanical constraint method to generate physiological femur biomechanics. The biomechanical method yielded FHD (< 1 mm), strains (approaching 1000 µε), and stresses (< 60 MPa), which were consistent with physiological observations and similar to predictions from the inertia relief method (average coefficient of determination = 0.97, average normalized root mean square error = 0.17). Our results highlight the superior performance of the biomechanical method compared to current methods of constraint for both healthy and pathological femurs.
Collapse
Affiliation(s)
- Alireza Y Bavil
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Emmanuel Eghan-Acquah
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Laura E Diamond
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Rod Barrett
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Christopher P Carty
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Martina Barzan
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - Azadeh Nasseri
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - David G Lloyd
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia
| | - David J Saxby
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia.
- School of Health Sciences and Social Work, Griffith University, Gold Coast, Australia.
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia.
| | - Stefanie Feih
- Griffith Centre of Biomedical and Rehabilitation Engineering (GCORE), Griffith University, Gold Coast, Australia.
- Advanced Design and Prototyping Technologies (ADaPT) Institute, Griffith University, Gold Coast, Australia.
- School of Engineering and Built Environment, Griffith University, Gold Coast, Australia.
| |
Collapse
|
10
|
Baleani M, Erani P, Acciaioli A, Schileo E. Tensile Yield Strain of Human Cortical Bone from the Femoral Diaphysis Is Constant among Healthy Adults and across the Anatomical Quadrants. Bioengineering (Basel) 2024; 11:395. [PMID: 38671816 PMCID: PMC11048186 DOI: 10.3390/bioengineering11040395] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 04/12/2024] [Accepted: 04/16/2024] [Indexed: 04/28/2024] Open
Abstract
The literature suggests that the yield strain of cortical bone is invariant to its stiffness (elastic modulus) and strength (yield stress). However, data about intra-individual variations, e.g., the influence of different collagen/mineral organisations observed in bone aspects withstanding different habitual loads, are lacking. The hypothesis that the yield strain of human cortical bone tissue, retrieved from femoral diaphyseal quadrants subjected to different habitual loads, is invariant was tested. Four flat dumbbell-shaped specimens were machined from each quadrant of the proximal femoral diaphysis of five adult donors for a total of 80 specimens. Two extensometers attached to the narrow specimen region were used to measure deformation during monotonic tensile testing. The elastic modulus (linear part of the stress-strain curve) and yield strain/stress at a 0.2% offset were obtained. Elastic modulus and yield stress values were, respectively, in the range of 12.2-20.5 GPa and 75.9-136.6 MPa and exhibited a positive linear correlation. All yield strain values were in the narrow range of 0.77-0.87%, regardless of the stiffness and strength of the tissue and the anatomical quadrant. In summary, the results corroborate the hypothesis that tensile yield strain in cortical bone is invariant, irrespective also of the anatomical quadrant. The mean yield strain value found in this study is similar to what was reported by inter-species and evolution studies but slightly higher than previous reports in humans, possibly because of the younger age of our subjects. Further investigations are needed to elucidate a possible dependence of yield strain on age.
Collapse
Affiliation(s)
- Massimiliano Baleani
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (P.E.); (A.A.)
| | - Paolo Erani
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (P.E.); (A.A.)
| | - Alice Acciaioli
- Laboratorio di Tecnologia Medica, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy; (P.E.); (A.A.)
| | - Enrico Schileo
- Laboratorio di Bioingegneria Computazionale, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, Italy;
| |
Collapse
|
11
|
Majcher KB, Kontulainen SA, Leswick DA, Dolovich AT, Johnston JD. Magnetic resonance imaging based finite element modelling of the proximal femur: a short-term in vivo precision study. Sci Rep 2024; 14:7029. [PMID: 38528237 DOI: 10.1038/s41598-024-57768-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Accepted: 03/21/2024] [Indexed: 03/27/2024] Open
Abstract
Proximal femoral fractures are a serious life-threatening injury with high morbidity and mortality. Magnetic resonance (MR) imaging has potential to non-invasively assess proximal femoral bone strength in vivo through usage of finite element (FE) modelling (a technique referred to as MR-FE). To precisely assess bone strength, knowledge of measurement error associated with different MR-FE outcomes is needed. The objective of this study was to characterize the short-term in vivo precision errors of MR-FE outcomes (e.g., stress, strain, failure loads) of the proximal femur for fall and stance loading configurations using 13 participants (5 males and 8 females; median age: 27 years, range: 21-68), each scanned 3 times. MR-FE models were generated, and mean von Mises stress and strain as well as principal stress and strain were calculated for 3 regions of interest. Similarly, we calculated the failure loads to cause 5% of contiguous elements to fail according to the von Mises yield, Brittle Coulomb-Mohr, normal principal, and Hoffman stress and strain criteria. Precision (root-mean squared coefficient of variation) of the MR-FE outcomes ranged from 3.3% to 11.8% for stress and strain-based mechanical outcomes, and 5.8% to 9.0% for failure loads. These results provide evidence that MR-FE outcomes are a promising non-invasive technique for monitoring femoral strength in vivo.
Collapse
Affiliation(s)
- Kadin B Majcher
- Department of Mechanical Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK, S7N 5A9, Canada
| | - Saija A Kontulainen
- College of Kinesiology, University of Saskatchewan, 87 Campus Drive, Saskatoon, SK, S7N 0W6, Canada.
- Division of Biomedical Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK, S7N 5A9, Canada.
| | - David A Leswick
- Department of Medical Imaging, University of Saskatchewan, 103 Hospital Drive, Saskatoon, SK, S7N 0W8, Canada
| | - Allan T Dolovich
- Department of Mechanical Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK, S7N 5A9, Canada
- Division of Biomedical Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK, S7N 5A9, Canada
| | - James D Johnston
- Department of Mechanical Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK, S7N 5A9, Canada.
- Division of Biomedical Engineering, University of Saskatchewan, 57 Campus Drive, Saskatoon, SK, S7N 5A9, Canada.
| |
Collapse
|
12
|
Skedros JG, Dayton MR, Bloebaum RD, Bachus KN, Cronin JT. Strain-mode-specific mechanical testing and the interpretation of bone adaptation in the deer calcaneus. J Anat 2024; 244:411-423. [PMID: 37953064 PMCID: PMC10862189 DOI: 10.1111/joa.13971] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2023] [Revised: 10/18/2023] [Accepted: 10/21/2023] [Indexed: 11/14/2023] Open
Abstract
The artiodactyl (deer and sheep) calcaneus is a model that helps in understanding how many bones achieve anatomical optimization and functional adaptation. We consider how the dorsal and plantar cortices of these bones are optimized in quasi-isolation (the conventional view) versus in the context of load sharing along the calcaneal shaft by "tension members" (the plantar ligament and superficial digital flexor tendon). This load-sharing concept replaces the conventional view, as we have argued in a recent publication that employs an advanced analytical model of habitual loading and fracture risk factors of the deer calcaneus. Like deer and sheep calcanei, many mammalian limb bones also experience prevalent bending, which seems problematic because the bone is weaker and less fatigue-resistant in tension than compression. To understand how bones adapt to bending loads and counteract deleterious consequences of tension, it is important to examine both strain-mode-specific (S-M-S) testing (compression testing of bone habitually loaded in compression; tension testing of bone habitually loaded in tension) and non-S-M-S testing. Mechanical testing was performed on individually machined specimens from the dorsal "compression cortex" and plantar "tension cortex" of adult deer calcanei and were independently tested to failure in one of these two strain modes. We hypothesized that the mechanical properties of each cortex region would be optimized for its habitual strain mode when these regions are considered independently. Consistent with this hypothesis, energy absorption parameters were approximately three times greater in S-M-S compression testing in the dorsal/compression cortex when compared to non-S-M-S tension testing of the dorsal cortex. However, inconsistent with this hypothesis, S-M-S tension testing of the plantar/tension cortex did not show greater energy absorption compared to non-S-M-S compression testing of the plantar cortex. When compared to the dorsal cortex, the plantar cortex only had a higher elastic modulus (in S-M-S testing of both regions). Therefore, the greater strength and capacity for energy absorption of the dorsal cortex might "protect" the weaker plantar cortex during functional loading. However, this conventional interpretation (i.e., considering adaptation of each cortex in isolation) is rejected when critically considering the load-sharing influences of the ligament and tendon that course along the plantar cortex. This important finding/interpretation has general implications for a better understanding of how other similarly loaded bones achieve anatomical optimization and functional adaptation.
Collapse
Affiliation(s)
- John G Skedros
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
| | - Michael R Dayton
- Department of Orthopedics, University of Colorado, Aurora, Colorado, USA
| | - Roy D Bloebaum
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
| | - Kent N Bachus
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
- Research Service, Veterans Affair Medical Center, Salt Lake City, Utah, USA
| | - John T Cronin
- Department of Orthopaedics, University of Utah, Salt Lake City, Utah, USA
| |
Collapse
|
13
|
Aitken HD, Yen YM, Kiapour AM, Sailer WM, Holt JB, Goetz JE, Scott EJ. The Effects of Residual Femoral Deformity on Computed Contact Mechanics in Patients Treated With In Situ Fixation for Slipped Capital Femoral Epiphysis. J Pediatr Orthop 2024; 44:e218-e225. [PMID: 38108380 DOI: 10.1097/bpo.0000000000002596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
OBJECTIVE In situ fixation for treatment of slipped capital femoral epiphysis (SCFE) can stabilize the epiphysis and prevent further joint deformation but often leaves residual deformity that may adversely affect intra-articular contact mechanics. The purpose of this study was to investigate the relationship between residual deformity and contact mechanics in the post-SCFE hip. METHODS Patient-specific hip models were created for 19 patients with SCFE treated with in situ fixation. For each model, discrete element analysis was used to compute cumulative acetabular and femoral contact stress exposure during a walking gait cycle. Slip severity was evaluated for each patient using the two-dimensional Southwick angle and a novel three-dimensional (3D) assessment of multiplanar femoral deformity (3D slip angle). RESULTS Of the SCFE cases, 2/7 mild (Southwick angle ≤30 degrees) had peak cumulative femoral exposures equivalent to that of severe (Southwick angle ≥60 degrees) cases. Severe SCFE cases had higher peak ( P = 0.015) and mean ( P = 0.028) femoral contact stress exposure and lower cumulative femoral contact area ( P = 0.003) than mild (Southwick angle ≤30 degrees) SCFE cases. Mean femoral contact stress exposure was also higher in severe SCFE cases than in moderate SCFE cases ( P = 0.027). Acetabular and femoral contact mechanics metrics typically demonstrated stronger correlations with 3D slip angle than two-dimensional Southwick angle. CONCLUSIONS Increased slip severity adversely impacts intra-articular femoral contact mechanics. Contact mechanics metrics demonstrate higher correlations with 3D slip angle, indicating that this novel measurement may better describe global deformity and its relationship to intra-articular mechanics; however, the modest strength of these correlations may also imply that global impingement-generating deformity is not the primary factor driving contact mechanics in the post-SCFE hip. CLINICAL RELEVANCE Greater slip severity adversely impacts contact mechanics in the post-SCFE hip. However, focal regions of high contact stress were seen even in mild SCFE deformities, suggesting some type of deformity correction should be considered even for mild slips to alleviate secondary impingement, address focal incongruities, and reduce osteoarthritis development/progression.
Collapse
Affiliation(s)
| | - Yi-Meng Yen
- Department of Orthopaedic Surgery and Sports Medicine, Boston Children's Hospital, Boston, MA
| | - Ata M Kiapour
- Department of Orthopaedic Surgery and Sports Medicine, Boston Children's Hospital, Boston, MA
| | | | | | - Jessica E Goetz
- Department of Orthopedics and Rehabilitation
- Department of Biomedical Engineering, University of Iowa, Iowa City, IA
| | | |
Collapse
|
14
|
Incze-Bartha Z, Incze-Bartha S, Simon-Szabó Z, Feier AM, Vunvulea V, Nechifor-Boila AI, Pastorello Y, Denes L. Finite Element Analysis of Various Osteotomies Used in the Treatment of Developmental Hip Dysplasia in Children. J Pers Med 2024; 14:189. [PMID: 38392622 PMCID: PMC10889920 DOI: 10.3390/jpm14020189] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Revised: 01/21/2024] [Accepted: 02/03/2024] [Indexed: 02/24/2024] Open
Abstract
Late-discovered developmental hip dysplasia deformities often necessitate complex surgical treatments and meticulous preoperative planning. The selection of osteotomies is contingent upon the patient's age and the specific structural deformity of the hip. In our anatomical hip model, derived from the data of a 12-year-old patient, we performed virtual osteotomies that are commonly recommended for such cases. We precisely constructed geometric models for various osteotomies, including the Dega, Pemberton, Tönnis, Ganz, Chiari pelvic, and Pauwels femoral osteotomies. We employed Autodesk Inventor for the finite element analysis of the hip joint and the corrective osteotomies. In comparing one-stage osteotomies, we noted that the Dega and Ganz pelvic osteotomies, especially when combined with the Pauwels femoral osteotomy, yielded the most favorable outcomes. These combinations led to enhanced femoral head coverage and reduced intra-articular pressure. Furthermore, we calculated the femoral head-to-acetabulum volume ratio for both the Dega and Pauwels osteotomies. The encouraging results we obtained advocate for the integration of finite element analysis in virtual osteotomies of the pelvis and femur as a preoperative tool in the management of developmental hip dysplasia.
Collapse
Affiliation(s)
- Zsuzsanna Incze-Bartha
- Department of Anatomy, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Sandor Incze-Bartha
- Department of Orthopedics and Traumatology, "Fogolyan Kristof" County Hospital Sfantu Gheorghe, 520064 Covasna, Romania
| | - Zsuzsánna Simon-Szabó
- Department of Pathophysiology, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Andrei Marian Feier
- Department of Orthopaedics and Traumatology, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540142 Targu Mures, Romania
| | - Vlad Vunvulea
- Department of Anatomy, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Alin Ioan Nechifor-Boila
- Department of Anatomy, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Ylenia Pastorello
- Department of Anatomy, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
| | - Lorand Denes
- Department of Anatomy, "George Emil Palade" University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania
| |
Collapse
|
15
|
Aghajanzadeh MS, Imani R, Nazarpak MH, McInnes SJP. Augmented physical, mechanical, and cellular responsiveness of gelatin-aldehyde modified xanthan hydrogel through incorporation of silicon nanoparticles for bone tissue engineering. Int J Biol Macromol 2024; 259:129231. [PMID: 38185310 DOI: 10.1016/j.ijbiomac.2024.129231] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2023] [Revised: 12/20/2023] [Accepted: 01/02/2024] [Indexed: 01/09/2024]
Abstract
Bioactive scaffolds fabricated from a combination of organic and inorganic biomaterials are a promising approach for addressing defects in bone tissue engineering. In the present study, a self-crosslinked nanocomposite hydrogel, composed of gelatin/aldehyde-modified xanthan (Gel-AXG) is successfully developed by varying concentrations of porous silicon nanoparticles (PSiNPs). The effect of PSiNPs incorporation on physical, mechanical, and biological performance of the nanocomposite hydrogel is evaluated. Morphological analysis reveals formation of highly porous 3D microstructures with interconnected pores in all nanocomposite hydrogels. Increased content of PSiNPs results in a lower swelling ratio, reduced porosity and pore size, which in turn impeded media penetration and slowed down the degradation process. In addition, remarkable enhancements in dynamic mechanical properties are observed in Gel-AXG-8%Si (compressive strength: 0.6223 MPa at 90 % strain and compressive modulus: 0.054 MPa), along with improved biomineralization ability via hydroxyapatite formation after immersion in simulated body fluid (SBF). This optimized nanocomposite hydrogel provides a sustained release of Si ions at safe dose levels. Furthermore, in-vitro cytocompatibility studies using MG-63 cells exhibited remarkable performance in terms of cell attachment, proliferation, and ALP activity for Gel-AXG-8%Si. These findings suggest that the prepared nanocomposite hydrogel holds promising potential as a scaffold for bone tissue engineering.
Collapse
Affiliation(s)
| | - Rana Imani
- Department of Biomedical Engineering, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran.
| | - Masoumeh Haghbin Nazarpak
- New Technologies Research Center, Amirkabir University of Technology (Tehran Polytechnic), Tehran, Iran
| | - Steven J P McInnes
- UniSA STEM, Mawson Lakes Campus, University of South Australia, Mawson Lakes, South Australia, Australia
| |
Collapse
|
16
|
Abdulaziz D, Anastasiou AD, Panagiotopoulou V, Raif EM, Giannoudis PV, Jha A. Physiologically engineered porous titanium/brushite scaffolds for critical-size bone defects: A design and manufacturing study. J Mech Behav Biomed Mater 2023; 148:106223. [PMID: 37976684 DOI: 10.1016/j.jmbbm.2023.106223] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2023] [Revised: 10/31/2023] [Accepted: 11/03/2023] [Indexed: 11/19/2023]
Abstract
Repairing critical-size bone defects still represents a critical clinical challenge in the field of trauma surgery. This study focuses on a physiological design and manufacturing of porous composite scaffold (titanium Ti with 10 % mole iron doped brushite DCPD-Fe3+) which can mimic the biomechanical properties of natural cortical bone, specifically for the purpose of repairing critical-size defects. To achieve this, the principle of design of experiments (DOE) was applied for investigating the impact of sintering temperature, mineral ratio, and volume fraction of porosity on the mechanical properties of the fabricated scaffolds. The fabricated scaffolds had open porosity up to 60 %, with pore size approximately between 100 μm and 850 μm. The stiffness of the porous composite scaffolds varied between 3.30 GPa and 20.50 GPa, while the compressive strength ranged from approximately 130 MPa-165 MPa at sintering temperatures equal to or exceeding 1000 °C. Scaffolds with higher porosity and mineral content demonstrated lower stiffness values, resembling natural bone. Numerical simulation was employed by Ansys Workbench to investigate the stress and strain distribution of a critical size defect in mid-shaft femur which was designed to be replaced with the fabricated scaffold. The fabricated scaffolds showed flexible biomechanical behaviour at the bone/scaffold interface, generating lower stress levels and indicating a better match with the femoral shaft stiffness. The experimental and numerical findings demonstrated promising applications for manufacturing a patient-specific bone scaffold for critical and potentially large defects for reducing stress shielding and minimizing non-union risk.
Collapse
Affiliation(s)
- Dina Abdulaziz
- School of Chemical and Process Engineering, University of Leeds, Leeds, LS2 9JT, UK.
| | - Antonios D Anastasiou
- Department of Chemical Engineering, University of Manchester, Manchester, M1 3AL, UK
| | | | - El Mostafa Raif
- Faculty of Medicine and Health, School of Dentistry, University of Leeds, Leeds, LS2 9JT, UK
| | - Peter V Giannoudis
- Academic Department of Trauma and Orthopaedic Surgery, School of Medicine, University of Leeds, Leeds, LS2 9JT, UK
| | - Animesh Jha
- School of Chemical and Process Engineering, University of Leeds, Leeds, LS2 9JT, UK
| |
Collapse
|
17
|
Incze-Bartha Z, Incze-Bartha S, Simon Szabó Z, Feier AM, Vunvulea V, Nechifor-Boilă IA, Pastorello Y, Szasz D, Dénes L. Finite Element Analysis of Normal and Dysplastic Hip Joints in Children. J Pers Med 2023; 13:1593. [PMID: 38003908 PMCID: PMC10672490 DOI: 10.3390/jpm13111593] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Revised: 11/07/2023] [Accepted: 11/08/2023] [Indexed: 11/26/2023] Open
Abstract
From a surgical point of view, quantification cannot always be achieved in the developmental deformity in hip joints, but finite element analysis can be a helpful tool to compare normal joint architecture with a dysplastic counterpart. CT scans from the normal right hip of an 8-year-old boy and the dysplastic left hip of a 12-year-old girl were used to construct our geometric models. In a three-dimensional model construction, distinctions were made between the cortical bone, trabecular bone, cartilage, and contact nonlinearities of the hip joint. The mathematical model incorporated the consideration of the linear elastic and isotropic properties of bony tissue in children, separately for the cortical bone, trabecular bone, and articular cartilage. Hexahedral elements were used in Autodesk Inventor software version 2022 ("Ren") for finite element analysis of the two hips in the boundary conditions of the single-leg stance. In the normal hip joint on the cartilaginous surfaces of the acetabulum, we found a kidney-shaped stress distribution in a 471,672 mm2 area. The measured contact pressure values were between 3.0 and 4.3 MPa. In the dysplastic pediatric hip joint on a patch of 205,272 mm2 contact area, the contact pressure values reached 8.5 MPa. Furthermore, the acetabulum/femur head volume ratio was 20% higher in the dysplastic hip joint. We believe that the knowledge gained from the normal and dysplastic pediatric hip joints can be used to develop surgical treatment methods and quantify and compare the efficiency of different surgical treatments used in children with hip dysplasia.
Collapse
Affiliation(s)
- Zsuzsánna Incze-Bartha
- Department of Anatomy, “George Emil Palade” University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania; (Z.I.-B.)
| | - Sandor Incze-Bartha
- Department of Orthopedics and Traumatology, “Fogolyan Kristof” County Hospital Sfantu Gheorghe, 520064 Covasna, Romania
| | - Zsuzsánna Simon Szabó
- Department of Anatomy, “George Emil Palade” University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania; (Z.I.-B.)
| | - Andrei Marian Feier
- Department of Orthopaedics and Traumatology, “George Emil Palade” University of Medicine, Pharmacy, Science, and Technology of Targu Mures, 540142 Targu Mures, Romania
| | - Vlad Vunvulea
- Department of Anatomy, “George Emil Palade” University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania; (Z.I.-B.)
| | - Ioan Alin Nechifor-Boilă
- Department of Anatomy, “George Emil Palade” University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania; (Z.I.-B.)
| | - Ylenia Pastorello
- Department of Anatomy, “George Emil Palade” University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania; (Z.I.-B.)
| | - Dezso Szasz
- Department of Orthopedics and Traumatology, “Fogolyan Kristof” County Hospital Sfantu Gheorghe, 520064 Covasna, Romania
| | - Lóránd Dénes
- Department of Anatomy, “George Emil Palade” University of Medicine, Pharmacy, Science and Technology of Targu Mures, 540139 Targu Mures, Romania; (Z.I.-B.)
| |
Collapse
|
18
|
Soltanihafshejani N, Peroni F, Toniutti S, Bitter T, Tanck E, Eggermont F, Verdonschot N, Janssen D. The application of an isotropic crushable foam model to predict the femoral fracture risk. PLoS One 2023; 18:e0288776. [PMID: 37498946 PMCID: PMC10374151 DOI: 10.1371/journal.pone.0288776] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Accepted: 07/03/2023] [Indexed: 07/29/2023] Open
Abstract
For biomechanical simulations of orthopaedic interventions, it is imperative to implement a material model that can realistically reproduce the nonlinear behavior of the bone structure. However, a proper material model that adequately combines the trabecular and cortical bone response is not yet widely identified. The current paper aims to investigate the possibility of using an isotropic crushable foam (ICF) model dependent on local bone mineral density (BMD) for simulating the femoral fracture risk. The elastoplastic properties of fifty-nine human femoral trabecular cadaveric bone samples were determined and combined with existing cortical bone properties to characterize two forms of the ICF model, a continuous and discontinuous model. Subsequently, the appropriateness of this combined material model was evaluated by simulating femoral fracture experiments, and a comparison with earlier published results of a softening Von-Mises (sVM) material model was made. The obtained mechanical properties of the trabecular bone specimens were comparable to previous findings. Furthermore, the ultimate failure load predicted by the simulations of femoral fractures was on average 79% and 90% for the continuous and discontinuous forms of the ICF model and 82% of the experimental value for the sVM material model. Also, the fracture locations predicted by ICF models were comparable to the experiments. In conclusion, a nonlinear material model dependent on BMD was characterized for human femoral bone. Our findings indicate that the ICF model could predict the femoral bone strength and reproduce the variable fracture locations in the experiments.
Collapse
Affiliation(s)
- Navid Soltanihafshejani
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Laboratory, Nijmegen, The Netherlands
| | - Federica Peroni
- Polytechnic University of Milan, Department of Biomedical Engineering, Milan, Italy
| | - Sara Toniutti
- Polytechnic University of Milan, Department of Biomedical Engineering, Milan, Italy
| | - Thom Bitter
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Laboratory, Nijmegen, The Netherlands
| | - Esther Tanck
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Laboratory, Nijmegen, The Netherlands
| | - Florieke Eggermont
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Laboratory, Nijmegen, The Netherlands
| | - Nico Verdonschot
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Laboratory, Nijmegen, The Netherlands
- University of Twente, Laboratory for Biomechanical Engineering, Faculty of Engineering Technology, Enschede, The Netherlands
| | - Dennis Janssen
- Radboud University Medical Center, Radboud Institute for Health Sciences, Orthopaedic Research Laboratory, Nijmegen, The Netherlands
| |
Collapse
|
19
|
Hu X, Zhang Z, Wu H, Yang S, Zhao W, Che L, Wang Y, Cao J, Li K, Qian Z. Progress in the application of 3D-printed sodium alginate-based hydrogel scaffolds in bone tissue repair. BIOMATERIALS ADVANCES 2023; 152:213501. [PMID: 37321007 DOI: 10.1016/j.bioadv.2023.213501] [Citation(s) in RCA: 24] [Impact Index Per Article: 12.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/21/2022] [Revised: 05/21/2023] [Accepted: 06/05/2023] [Indexed: 06/17/2023]
Abstract
In recent years, hydrogels have been widely used in the biomedical field as materials with excellent bionic structures and biological properties. Among them, the excellent comprehensive properties of natural polymer hydrogels represented by sodium alginate have attracted the great attention of researchers. At the same time, by physically blending sodium alginate with other materials, the problems of poor cell adhesion and mechanical properties of sodium alginate hydrogels were directly improved without chemical modification of sodium alginate. The composite blending of multiple materials can also improve the functionality of sodium alginate hydrogels, and the prepared composite hydrogel also has a larger application field. In addition, based on the adjustable viscosity of sodium alginate-based hydrogels, sodium alginate-based hydrogels can be loaded with cells to prepare biological ink, and the scaffold can be printed out by 3D printing technology for the repair of bone defects. This paper first summarizes the improvement of the properties of sodium alginate and other materials after physical blending. Then, it summarizes the application progress of sodium alginate-based hydrogel scaffolds for bone tissue repair based on 3D printing technology in recent years. Moreover, we provide relevant opinions and comments to provide a theoretical basis for follow-up research.
Collapse
Affiliation(s)
- Xulin Hu
- Clinical Medical College and Affiliated Hospital of Chengdu University, School of Mechanical Engineering of Chengdu University, Chengdu 610081, China; State Key Laboratory of Biotherapy, West China Hospital, West China Medical School, Sichuan University, Chengdu 610041, China
| | - Zhen Zhang
- Clinical Medical College and Affiliated Hospital of Chengdu University, School of Mechanical Engineering of Chengdu University, Chengdu 610081, China
| | - Haoming Wu
- Clinical Medical College and Affiliated Hospital of Chengdu University, School of Mechanical Engineering of Chengdu University, Chengdu 610081, China
| | - Shuhao Yang
- Clinical Medical College and Affiliated Hospital of Chengdu University, School of Mechanical Engineering of Chengdu University, Chengdu 610081, China
| | - Weiming Zhao
- Clinical Medical College and Affiliated Hospital of Chengdu University, School of Mechanical Engineering of Chengdu University, Chengdu 610081, China
| | - Lanyu Che
- Clinical Medical College and Affiliated Hospital of Chengdu University, School of Mechanical Engineering of Chengdu University, Chengdu 610081, China
| | - Yao Wang
- Clinical Medical College and Affiliated Hospital of Chengdu University, School of Mechanical Engineering of Chengdu University, Chengdu 610081, China
| | - Jianfei Cao
- School of Materials and Environmental Engineering, Chengdu Technological University, Chengdu 610031, China
| | - Kainan Li
- Clinical Medical College and Affiliated Hospital of Chengdu University, School of Mechanical Engineering of Chengdu University, Chengdu 610081, China
| | - Zhiyong Qian
- State Key Laboratory of Biotherapy, West China Hospital, West China Medical School, Sichuan University, Chengdu 610041, China.
| |
Collapse
|
20
|
He L, Yin J, Gao X. Additive Manufacturing of Bioactive Glass and Its Polymer Composites as Bone Tissue Engineering Scaffolds: A Review. Bioengineering (Basel) 2023; 10:672. [PMID: 37370603 DOI: 10.3390/bioengineering10060672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2023] [Revised: 05/20/2023] [Accepted: 05/25/2023] [Indexed: 06/29/2023] Open
Abstract
Bioactive glass (BG) and its polymer composites have demonstrated great potential as scaffolds for bone defect healing. Nonetheless, processing these materials into complex geometry to achieve either anatomy-fitting designs or the desired degradation behavior remains challenging. Additive manufacturing (AM) enables the fabrication of BG and BG/polymer objects with well-defined shapes and intricate porous structures. This work reviewed the recent advancements made in the AM of BG and BG/polymer composite scaffolds intended for bone tissue engineering. A literature search was performed using the Scopus database to include publications relevant to this topic. The properties of BG based on different inorganic glass formers, as well as BG/polymer composites, are first introduced. Melt extrusion, direct ink writing, powder bed fusion, and vat photopolymerization are AM technologies that are compatible with BG or BG/polymer processing and were reviewed in terms of their recent advances. The value of AM in the fabrication of BG or BG/polymer composites lies in its ability to produce scaffolds with patient-specific designs and the on-demand spatial distribution of biomaterials, both contributing to effective bone defect healing, as demonstrated by in vivo studies. Based on the relationships among structure, physiochemical properties, and biological function, AM-fabricated BG or BG/polymer composite scaffolds are valuable for achieving safer and more efficient bone defect healing in the future.
Collapse
Affiliation(s)
- Lizhe He
- Center for Medical and Engineering Innovation, The First Affiliated Hospital of Ningbo University, Ningbo 315010, China
- The State Key Laboratory of Fluid Power Transmission and Control Systems, Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, School of Mechanical Engineering, Zhejiang University, Hangzhou 310028, China
| | - Jun Yin
- The State Key Laboratory of Fluid Power Transmission and Control Systems, Key Laboratory of 3D Printing Process and Equipment of Zhejiang Province, School of Mechanical Engineering, Zhejiang University, Hangzhou 310028, China
| | - Xiang Gao
- Department of Neurosurgery, The First Affiliated Hospital of Ningbo University, Ningbo 315010, China
| |
Collapse
|
21
|
Wang Y, Yang D, Zhao L, Xiao B, Ma Q, Dong L, Li X, Zhang Y, Zhang Z, Luo Y. Finite Element Analysis of Mechanical Characteristics of Internal Fixation for Treatment of Proximal Femoral Osteolytic Lesions in Children. Orthop Surg 2023; 15:628-638. [PMID: 36597674 PMCID: PMC9891963 DOI: 10.1111/os.13591] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/29/2022] [Revised: 10/13/2022] [Accepted: 10/19/2022] [Indexed: 01/05/2023] Open
Abstract
OBJECTIVES Clinically, it is very difficult to prevent pathological fracture caused by high recurrence rate of osteolytic disease of proximal femur in children. At present, there is no consensus in clinical studies of which internal fixation method can significantly reduce the probability of recurrence of pathological fracture. The study aims to research the mechanical properties of different internal fixations in the treatment of osteolytic lesions of proximal femur in children by finite element analysis, and to find out the optimal treatment. METHODS Based on finite element analysis, the osteolytic disease models of the femoral neck and intertrochanter in a child (8-year-old, boy) were established respectively, and different internal fixation models (plate and titanium elastic intramedullary nails, TENs) were assembled. For the osteolytic lesion of the femoral neck: model A1 was assembled with a plate; model A2 with two TENs crossing the physis; model A3 with two TENs without crossing the physis. And for pertrochanteric osteolytic lesion: model B1 was assembled with a plate, model B2 with two TENs crossing the physis and model B3 with two TENs without crossing the physis. The Eccentric bearing load, torsional restraintal restraint of calcar femorale and composite load were analyzed for each models. RESULTS When the yield strain of each model is reached, the stress concentration points are located in the proximal and distal femoral calcar. In the model of femoral neck lesions, the failure load of model A1 and model A2 are the same (1250 N), and the failure load of model A3 (980 N) is significantly lower than that of the former two; in the model of intertrochanteric lesions, the failure load of model B2 is the largest (1350 N), and the failure load of model B1 (1220 N) is lower than that of model B3 (1260 N), but both are smaller than that of model B2. CONCLUSION Through finite element analysis, TENs through the epiphyseal plate, is found to be the better internal fixation method for femoral neck lesions and intertrochanteric lesions under two different working conditions. The results of clinical correlation study provide new biomechanical information for orthopedic doctors to consider different treatment options for osteolytic lesions of proximal femur.
Collapse
Affiliation(s)
- Yi‐chen Wang
- Department of Orthopedics, Shanghai Children's Hospital, School of medicineShanghai Jiao Tong UniversityShanghaiChina
| | - Dan Yang
- Department of Orthopedics, Shanghai Children's Hospital, School of medicineShanghai Jiao Tong UniversityShanghaiChina
| | - Li‐hua Zhao
- Department of Orthopedics, Shanghai Children's Hospital, School of medicineShanghai Jiao Tong UniversityShanghaiChina
| | - Bo Xiao
- Department of Orthopedics, Shanghai Children's Hospital, School of medicineShanghai Jiao Tong UniversityShanghaiChina
| | - Qi‐chao Ma
- Department of Orthopedics, Shanghai Children's Hospital, School of medicineShanghai Jiao Tong UniversityShanghaiChina
| | - Liang‐chao Dong
- Department of Orthopedics, Shanghai Children's Hospital, School of medicineShanghai Jiao Tong UniversityShanghaiChina
| | - Xiang Li
- School of Mechanical EngineeringShanghai Jiao Tong UniversityShanghaiChina
| | - Yu‐guo Zhang
- Department of Orthopedics, Shanghai Children's Hospital, School of medicineShanghai Jiao Tong UniversityShanghaiChina
| | - Zi‐ming Zhang
- Department of Orthopedics, Shanghai Children's Hospital, School of medicineShanghai Jiao Tong UniversityShanghaiChina
| | - Yi Luo
- Department of Orthopedics, Shanghai Children's Hospital, School of medicineShanghai Jiao Tong UniversityShanghaiChina
| |
Collapse
|
22
|
Bulut E, Güçlü ZA. Evaluation of primary teeth affected by dental trauma in patients visiting a university clinic, part 2: dental injury types, treatment strategies, and complications. Clin Oral Investig 2023; 27:727-737. [PMID: 36502510 DOI: 10.1007/s00784-022-04820-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Accepted: 11/26/2022] [Indexed: 12/14/2022]
Abstract
OBJECTIVES This article focuses on treatments and complications in patients presenting dental trauma in primary teeth. Treatment alternatives begin with the decision of performing a procedure under clinical settings or pharmacological techniques (PC) in young children. Correct diagnosis and treatment are crucial to maximize the chances of a favorable outcome. MATERIALS AND METHODS The files of 320 patients aged 0-9 years who presented to the Erciyes University Faculty of Dentistry Department for dental trauma management in primary teeth were evaluated in between 2018 and 2021 for 3-year period. The following information were extracted from patients' records: injury type, affected teeth, caries condition of the teeth, treatment preferences of the dentists. Additionally postoperative complications and their management were evaluated. RESULTS While 63.1% of the traumatized teeth were caries-free, 35.8% of the teeth had caries. The most frequent dental injuries was simple crown fractures (42.9%), followed by complicated crown fractures (38.5%). Treatments were mostly done in clinical conditions (67.9%) and mostly patients attend regularly to follow-up visits (85.6%). Clinicians prefer more radical treatments under sedation or GA (92.4% extraction of injured tooth). Coronal discoloration was the most common complication, and 35.3% had pulp necrosis for longer term results. CONCLUSION Follow-up decisions made after concussion in the primary teeth might be appropriate for the patient. Examination of the complication status of primary teeth with simple crown fracture injury revealed that 59.5% of patients did not have any complications. Follow-up decisions were found to be appropriate for crowns with coloration alone. CLINICAL RELEVANCE All options should be considered to provide the best care for children after primary tooth trauma; this can be achieved by being informed about the treatment and its consequences, and if necessary, a positive prognosis can be achieved with an interdisciplinary approach.
Collapse
Affiliation(s)
- Esra Bulut
- Department of Pediatric Dentistry, Faculty of Dentistry and Hospitals, Erciyes University, Melikgazi, Kayseri, 38039, Turkey
| | - Zeynep Aslı Güçlü
- Department of Pediatric Dentistry, Faculty of Dentistry and Hospitals, Erciyes University, Melikgazi, Kayseri, 38039, Turkey.
| |
Collapse
|
23
|
Dudle A, Gugler Y, Pretterklieber M, Ferrari S, Lippuner K, Zysset P. 2D-3D reconstruction of the proximal femur from DXA scans: Evaluation of the 3D-Shaper software. Front Bioeng Biotechnol 2023; 11:1111020. [PMID: 36937766 PMCID: PMC10014626 DOI: 10.3389/fbioe.2023.1111020] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/29/2022] [Accepted: 02/15/2023] [Indexed: 03/05/2023] Open
Abstract
Introduction: Osteoporosis is currently diagnosed based on areal bone mineral density (aBMD) computed from 2D DXA scans. However, aBMD is a limited surrogate for femoral strength since it does not account for 3D bone geometry and density distribution. QCT scans combined with finite element (FE) analysis can deliver improved femoral strength predictions. However, non-negligible radiation dose and high costs prevent a systematic usage of this technique for screening purposes. As an alternative, the 3D-Shaper software (3D-Shaper Medical, Spain) reconstructs the 3D shape and density distribution of the femur from 2D DXA scans. This approach could deliver a more accurate estimation of femoral strength than aBMD by using FE analysis on the reconstructed 3D DXA. Methods: Here we present the first independent evaluation of the software, using a dataset of 77 ex vivo femora. We extend a prior evaluation by including the density distribution differences, the spatial correlation of density values and an FE analysis. Yet, cortical thickness is left out of this evaluation, since the cortex is not resolved in our FE models. Results: We found an average surface distance of 1.16 mm between 3D DXA and QCT images, which shows a good reconstruction of the bone geometry. Although BMD values obtained from 3D DXA and QCT correlated well (r 2 = 0.92), the 3D DXA BMD were systematically lower. The average BMD difference amounted to 64 mg/cm3, more than one-third of the 3D DXA BMD. Furthermore, the low correlation (r 2 = 0.48) between density values of both images indicates a limited reconstruction of the 3D density distribution. FE results were in good agreement between QCT and 3D DXA images, with a high coefficient of determination (r 2 = 0.88). However, this correlation was not statistically different from a direct prediction by aBMD. Moreover, we found differences in the fracture patterns between the two image types. QCT-based FE analysis resulted mostly in femoral neck fractures and 3D DXA-based FE in subcapital or pertrochanteric fractures. Discussion: In conclusion, 3D-Shaper generates an altered BMD distribution compared to QCT but, after careful density calibration, shows an interesting potential for deriving a standardized femoral strength from a DXA scan.
Collapse
Affiliation(s)
- Alice Dudle
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
- *Correspondence: Alice Dudle, ; Yvan Gugler,
| | - Yvan Gugler
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
- *Correspondence: Alice Dudle, ; Yvan Gugler,
| | - Michael Pretterklieber
- Division of Anatomy, Gottfried Schatz Research Center, Medical University of Graz, Graz, Austria
- Division of Anatomy, Center for Anatomy and Cell Biology, Medical University of Vienna, Vienna, Austria
| | - Serge Ferrari
- Division of Bone Diseases, Geneva University Hospitals (HUG), Geneva, Switzerland
| | - Kurt Lippuner
- Department of Osteoporosis, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland
| | - Philippe Zysset
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| |
Collapse
|
24
|
Thread shape, cortical bone thickness, and magnitude and distribution of stress caused by the loading of orthodontic miniscrews: finite element analysis. Sci Rep 2022; 12:12367. [PMID: 35859046 PMCID: PMC9300621 DOI: 10.1038/s41598-022-16662-w] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Accepted: 07/13/2022] [Indexed: 11/16/2022] Open
Abstract
Cortical bone thickness is assumed to be a major factor regulating miniscrew stability. We investigated stress distribution in two miniscrews with different thread shapes (type A and B) and in cortical bone of three different thicknesses using three-dimensional (3D) finite element (FE) models. More specifically, 3D FE models of two different miniscrews were created and placed obliquely or vertically into a cylindrical bone model representing different cortical bone thicknesses. When force was applied to the miniscrew, the stress distribution on the screw surface and in the peri-implant bone was assessed using FE methodology. Miniscrew safety was evaluated using a modified Soderberg safety factor. Screw head displacement increased with a decrease in cortical bone thickness, irrespective of screw type. The smallest minimum principal stresses on the screw surfaces remained constant in type A miniscrews on changes in cortical bone thickness. Minimum principal stresses also appeared on the cortical bone surface. Lower absolute values of minimum principal stresses were seen in type A miniscrews when placed vertically and with upward traction in obliquely placed type B miniscrews. Both miniscrews had acceptable safety factor values. Taken together, orthodontists should select and use the suitable miniscrew for each patient in consideration of bone properties.
Collapse
|
25
|
Predicting pullout strength of pedicle screws in broken bones from X-ray images. J Mech Behav Biomed Mater 2022; 134:105366. [PMID: 35870229 DOI: 10.1016/j.jmbbm.2022.105366] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2022] [Revised: 06/23/2022] [Accepted: 07/09/2022] [Indexed: 12/19/2022]
Abstract
Pedicle screw fixation is one of the most common procedures used in spinal fusion surgery. The screw loosening is a major concern, which may be caused by broken pedicles. In vitro pullout tests or insertion torque are the main approaches for assessing the stability of the screw; however, direct evidence was lacking for clinical human spines. Here, we aim to provide a model that can predict the pullout strengths of pedicle screws in various pedicle conditions from X-ray images. A weighted embedded bone volume (EBV) model is proposed for pullout strengths prediction by considering the bone heterogeneity and confinement of the screw. We showed that the pullout strength is proportional to the EBV for homogeneous bone and the weighted EBV for layered composite bone. The proposed weighted EBV model is validated with in vitro Sawbones® pullout experiments. The results show that the model has better accuracy than the simple EBV model, with a coefficient of determination of 0.94. The proposed weighted EBV model can help assess the stability of a pedicle screw in a broken pedicle by simply examining 2D X-ray images.
Collapse
|
26
|
Al-Barqawi MO, Church B, Thevamaran M, Thoma DJ, Rahman A. Experimental Validation and Evaluation of the Bending Properties of Additively Manufactured Metallic Cellular Scaffold Structures for Bone Tissue Engineering. MATERIALS (BASEL, SWITZERLAND) 2022; 15:3447. [PMID: 35629475 PMCID: PMC9143386 DOI: 10.3390/ma15103447] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/24/2022] [Revised: 04/11/2022] [Accepted: 04/29/2022] [Indexed: 01/27/2023]
Abstract
The availability of additive manufacturing enables the fabrication of cellular bone tissue engineering scaffolds with a wide range of structural and architectural possibilities. The purpose of bone tissue engineering scaffolds is to repair critical size bone defects due to extreme traumas, tumors, or infections. This research study presented the experimental validation and evaluation of the bending properties of optimized bone scaffolds with an elastic modulus that is equivalent to the young's modulus of the cortical bone. The specimens were manufactured using laser powder bed fusion technology. The morphological properties of the manufactured specimens were evaluated using both dry weighing and Archimedes techniques, and minor variations in the relative densities were observed in comparison with the computer-aided design files. The bending modulus of the cubic and diagonal scaffolds were experimentally investigated using a three-point bending test, and the results were found to agree with the numerical findings. A higher bending modulus was observed in the diagonal scaffold design. The diagonal scaffold was substantially tougher, with considerably higher energy absorption before fracture. The shear modulus of the diagonal scaffold was observed to be significantly higher than the cubic scaffold. Due to bending, the pores at the top side of the diagonal scaffold were heavily compressed compared to the cubic scaffold due to the extensive plastic deformation occurring in diagonal scaffolds and the rapid fracture of struts in the tension side of the cubic scaffold. The failure in struts in tension showed signs of ductility as necking was observed in fractured struts. Moreover, the fractured surface was observed to be rough and dull as opposed to being smooth and bright like in brittle fractures. Dimple fracture was observed using scanning electron microscopy as a result of microvoids emerging in places of high localized plastic deformation. Finally, a comparison of the mechanical properties of the studied BTE scaffolds with the cortical bone properties under longitudinal and transverse loading was investigated. In conclusion, we showed the capabilities of finite element analysis and additive manufacturing in designing and manufacturing promising scaffold designs that can replace bone segments in the human body.
Collapse
Affiliation(s)
- Mohammad O. Al-Barqawi
- Department of Civil and Environmental Engineering, University of Wisconsin, Milwaukee, WI 53211, USA;
| | - Benjamin Church
- Department of Material Science and Engineering, University of Wisconsin, Milwaukee, WI 53211, USA;
| | - Mythili Thevamaran
- Department of Material Science and Engineering, University of Wisconsin, Madison, WI 53706, USA; (M.T.); (D.J.T.)
| | - Dan J. Thoma
- Department of Material Science and Engineering, University of Wisconsin, Madison, WI 53706, USA; (M.T.); (D.J.T.)
| | - Adeeb Rahman
- Department of Civil and Environmental Engineering, University of Wisconsin, Milwaukee, WI 53211, USA;
| |
Collapse
|
27
|
Abe S, Kouhia R, Nikander R, Narra N, Hyttinen J, Sievänen H. Effect of fall direction on the lower hip fracture risk in athletes with different loading histories: A finite element modeling study in multiple sideways fall configurations. Bone 2022; 158:116351. [PMID: 35131487 DOI: 10.1016/j.bone.2022.116351] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 02/01/2022] [Accepted: 02/01/2022] [Indexed: 11/24/2022]
Abstract
Physical loading makes bones stronger through structural adaptation. Finding effective modes of exercise to improve proximal femur strength has the potential to decrease hip fracture risk. Previous proximal femur finite element (FE) modeling studies have indicated that the loading history comprising impact exercises is associated with substantially higher fracture load. However, those results were limited only to one specified fall direction. It remains thus unclear whether exercise-induced higher fracture load depends on the fall direction. To address this, using magnetic resonance images of proximal femora from 91 female athletes (mean age 24.7 years with >8 years competitive career) and their 20 non-athletic but physically active controls (mean age 23.7 years), proximal femur FE models were created in 12 different sideways fall configurations. The athletes were divided into five groups by typical loading patterns of their sports: high-impact (H-I: 9 triple- and 10 high-jumpers), odd-impact (O-I: 9 soccer and 10 squash players), high-magnitude (H-M: 17 powerlifters), repetitive-impact (R-I: 18 endurance runners), and repetitive non-impact (R-NI: 18 swimmers). Compared to the controls, the FE models showed that the H-I and R-I groups had significantly (p < 0.05) higher fracture loads, 11-17% and 22-28% respectively, in all fall directions while the O-I group had significantly 10-11% higher fracture loads in four fall directions. The H-M and R-NI groups did not show significant benefit in any direction. Also, the analyses of the minimum fall strength (MFS) among these multiple fall configurations confirmed significantly 15%, 11%, and 14% higher MFSs in these impact groups, respectively, compared to the controls. These results suggest that the lower hip fracture risk indicated by higher fracture loads in athletes engaged in high impact or repetitive impact sports is independent of fall direction whereas the lower fracture risk attributed to odd-impact exercise is more modest and specific to the fall direction. Moreover, in concordance with the literature, the present study also confirmed that the fracture risk increases if the impact is imposed on the more posterolateral aspect of the hip. The present results highlight the importance of engaging in the impact exercises to prevent hip fractures and call for retrospective studies to investigate whether specific impact exercise history in adolescence and young adulthood is also associated with lower incidence of hip fractures in later life.
Collapse
Affiliation(s)
- Shinya Abe
- Structural Mechanics, Faculty of Built Environment, Tampere University, Tampere, Finland.
| | - Reijo Kouhia
- Structural Mechanics, Faculty of Built Environment, Tampere University, Tampere, Finland
| | - Riku Nikander
- Gerontology Research Center, Faculty of Sports Sciences, University of Jyväskylä, Jyväskylä, Finland; Central Hospital of Central Finland, Jyväskylä, Finland
| | - Nathaniel Narra
- BioMediTech Unit, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Jari Hyttinen
- BioMediTech Unit, Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
| | - Harri Sievänen
- The UKK Institute for Health Promotion Research, Tampere, Finland
| |
Collapse
|
28
|
Yang Harmony TC, Yusof N, Ramalingam S, Baharin R, Syahrom A, Mansor A. Deep-Freezing Temperatures During Irradiation Preserves the Compressive Strength of Human Cortical Bone Allografts: A Cadaver Study. Clin Orthop Relat Res 2022; 480:407-418. [PMID: 34491235 PMCID: PMC8747490 DOI: 10.1097/corr.0000000000001968] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/15/2020] [Accepted: 08/16/2021] [Indexed: 02/03/2023]
Abstract
BACKGROUND Gamma irradiation, which minimizes the risk of infectious disease transmission when human bone allograft is used, has been found to negatively affect its biomechanical properties. However, in those studies, the deep-freezing temperature during irradiation was not necessarily maintained during transportation and sterilization, which may have affected the findings. Prior reports have also suggested that controlled deep freezing may mitigate the detrimental effects of irradiation on the mechanical properties of bone allograft. QUESTION/PURPOSE Does a controlled deep-freezing temperature during irradiation help preserve the compressive mechanical properties of human femoral cortical bone allografts? METHODS Cortical bone cube samples, each measuring 64 mm3, were cut from the mid-diaphyseal midshaft of five fresh-frozen cadaver femurs (four male donors, mean [range] age at procurement 42 years [42 to 43]) and were allocated via block randomization into one of three experimental groups (with equal numbers of samples from each donor allocated into each group). Each experimental group consisted of 20 bone cube samples. Samples irradiated in dry ice were subjected to irradiation doses ranging from 26.7 kGy to 27.1 kGy (mean 26.9 kGy) at a deep-freezing temperature below -40°C (the recommended long-term storage temperature for allografts). Samples irradiated in gel ice underwent irradiation doses ranging from 26.2 kGy and 26.4 kGy (mean 26.3 kGy) in a freezing temperature range between -40°C and 0°C. Acting as controls, samples in a third group were not subjected to gamma irradiation. The mechanical properties (0.2% offset yield stress, ultimate compression stress, toughness, and the Young modulus) of samples from each group were subsequently evaluated via axial compression loading to failure along the long axis of the bone. The investigators were blinded to sample group during compression testing. RESULTS The mean ultimate compression stress (84 ± 27 MPa versus 119 ± 31 MPa, mean difference 35 [95% CI 9 to 60]; p = 0.005) and toughness (3622 ± 1720 kJ/m3 versus 5854 ± 2900 kJ/m3, mean difference 2232 [95% CI 70 to 4394]; p = 0.009) of samples irradiated at a higher temperature range (-40°C to 0°C) were lower than in those irradiated at deep-freezing temperatures (below -40°C). The mean 0.2% offset yield stress (73 ± 28 MPa versus 109 ± 38 MPa, mean difference 36 [95% CI 11 to 60]; p = 0.002) and ultimate compression stress (84 ± 27 MPa versus 128 ± 40 MPa, mean difference 44 [95% CI 17 to 69]; p < 0.001) of samples irradiated at a higher temperature range (-40°C to 0°C) were lower than the nonirradiated control group samples. The mean 0.2% offset yield stress (73 ± 28 MPa versus 101 ± 28 MPa, mean difference 28 [95% CI 3 to 52]; p = 0.02; effect size = 1.0 [95% CI 0.8 to 1.2]) of samples irradiated at higher temperature range (-40°C to 0°C) were no different with the numbers available to those irradiated at deep-freezing temperature. The mean toughness (3622 ± 1720 kJ/m3 versus 6231 ± 3410 kJ/m3, mean difference 2609 [95% CI 447 to 4771]; p = 0.02; effect size = 1.0 [95% CI 0.8 to 1.2]) of samples irradiated at higher temperature range (-40°C to 0°C) were no different with the numbers available to the non-irradiated control group samples. The mean 0.2% offset yield stress, ultimate compression stress, and toughness of samples irradiated in deep-freezing temperatures (below -40°C) were not different with the numbers available to the non-irradiated control group samples. The Young modulus was not different with the numbers available among the three groups. CONCLUSION In this study, maintenance of a deep-freezing temperature below -40°C, using dry ice as a cooling agent, consistently mitigated the adverse effects of irradiation on the monotonic-compression mechanical properties of human cortical bone tissue. Preserving the mechanical properties of a cortical allograft, when irradiated in a deep-freezing temperature, may have resulted from attenuation of the deleterious, indirect effects of gamma radiation on its collagen architecture in a frozen state. Immobilization of water molecules in this state prevents radiolysis and the subsequent generation of free radicals. This hypothesis was supported by an apparent loss of the protective effect when a range of higher freezing temperatures was used during irradiation. CLINICAL RELEVANCE Deep-freezing temperatures below -40°C during gamma irradiation may be a promising approach to better retain the native mechanical properties of cortical bone allografts. A further study of the effect of deep-freezing during gamma radiation sterilization on sterility and other important biomechanical properties of cortical bone (such as, tensile strength, fracture toughness, and fatigue) is needed to confirm these findings.
Collapse
Affiliation(s)
- Tan Chern Yang Harmony
- Ministry of Health Malaysia, Federal Government Administrative Centre, Putrajaya, Malaysia
| | - Norimah Yusof
- Bone Bank, National Orthopaedic Centre of Excellence in Research and Learning, Kuala Lumpur, Malaysia
- Department of Orthopaedic Surgery, University of Malaya, Kuala Lumpur, Malaysia
- Jalan Universiti, Kuala Lumpur, Malaysia
| | - Saravana Ramalingam
- Bone Bank, National Orthopaedic Centre of Excellence in Research and Learning, Kuala Lumpur, Malaysia
- Department of Orthopaedic Surgery, University of Malaya, Kuala Lumpur, Malaysia
- Jalan Universiti, Kuala Lumpur, Malaysia
| | | | - Ardiyansyah Syahrom
- Medical Device Technology Center, Institute of Human Centered Engineering, Skudai Johor, Malaysia
- Faculty of Engineering, Universiti Teknologi Malaysia, Skudai Johor, Malaysia
| | - Azura Mansor
- Bone Bank, National Orthopaedic Centre of Excellence in Research and Learning, Kuala Lumpur, Malaysia
- Department of Orthopaedic Surgery, University of Malaya, Kuala Lumpur, Malaysia
- Jalan Universiti, Kuala Lumpur, Malaysia
| |
Collapse
|
29
|
Baron C, Follet H, Pithioux M, Payan C, Lasaygues P. Assessing the Elasticity of Child Cortical Bone. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2022; 1364:297-318. [DOI: 10.1007/978-3-030-91979-5_14] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 10/18/2022]
|
30
|
Szabo E, Rimnac C. Biomechanics of immature human cortical bone: A systematic review. J Mech Behav Biomed Mater 2021; 125:104889. [PMID: 34736022 DOI: 10.1016/j.jmbbm.2021.104889] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 09/10/2021] [Accepted: 10/06/2021] [Indexed: 12/31/2022]
Abstract
The whole bone geometry, microstructure, and mechanical properties of mature human bone are widely reported; however, immature bone (0-18 years) has not been similarly robustly characterized. There is an interest in analyzing and predicting the mechanical loading conditions associated with long bone diaphyseal fractures attributed to trauma in children. Thus, understanding the mechanical properties of immature bone in a temporal reference frame is an essential first step to understand diaphyseal fractures of pediatric long bones. The purpose of this systematic review was to ask, what is the state of knowledge regarding the 1) evolution of whole bone geometry and microstructure of immature pediatric bone as a function of maturation and 2) cortical bone density and experimental quasi-static mechanical properties at the tissue level in the diaphyseal region of immature pediatric long bones? The systematic search yielded 36 studies of the whole bone geometry, microstructure, and mechanical properties of immature pediatric long bones. The elastic modulus, yield stress, and ultimate stress were shown to generally increase with maturation, whereas the yield strain was approximately invariant; however, the specific year-to-year progression of these properties could not be characterized from the limited studies available. The results of this systematic search indicate there is a dearth of knowledge associated with the biomechanics of cortical bone from immature pediatric long bones; it also provides a basis for computational studies of immature human long bones. Additional biomechanical studies of immature human bone are necessary to develop a robust catalogue, which can be used in broad applications to understand fracture mechanics, bone pathologies, and athletic injury in the pediatric setting.
Collapse
Affiliation(s)
- Emily Szabo
- Case Western Reserve University, Department of Mechanical and Aerospace Engineering, 2123 Martin Luther King Jr Dr, Cleveland, OH, 44106, USA.
| | - Clare Rimnac
- Case Western Reserve University, Department of Mechanical and Aerospace Engineering, 2123 Martin Luther King Jr Dr, Cleveland, OH, 44106, USA.
| |
Collapse
|
31
|
Schileo E, Feltri P, Taddei F, di Settimi M, Di Martino A, Filardo G. A taper-fit junction to improve long bone reconstruction: A parametric In Silico model. J Mech Behav Biomed Mater 2021; 124:104790. [PMID: 34530302 DOI: 10.1016/j.jmbbm.2021.104790] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/23/2021] [Revised: 07/26/2021] [Accepted: 08/21/2021] [Indexed: 12/24/2022]
Abstract
PURPOSE Critical size long bone defects represent a clinical challenge in orthopaedic surgery. Various grafting techniques have been developed through the years, but they all present several downsides. A key requirement of all grafting techniques is the achievement of a continuous interface between host bone and graft to enhance both biological processes and mechanical stability. This study used a parametric in silico model to quantify the biomechanical effect of the inaccuracies inherent to current osteotomy techniques, and to test a new concept of accurate taper-fit junction that may improve the biomechanical parameters of the reconstruction under load. METHODS A population-based in-silico 3D model of the reconstruction of a long bone defect was built to represent a defect of the femoral mid-diaphysis. To fix the reconstruction a titanium plate was placed on the lateral aspect of the reconstruction. The model was modified to (i) quantify the biomechanical consequences of actual inaccuracies in the realization of a flat host-graft interface, (ii) compare the contact behaviour and bone strains among different taper angles of the new design and the current host-graft flat interface, (iii) evaluate the robustness of the taper-fit design to inter-subject variability in bone geometry and defect length. RESULTS The influence of 2° single-plane misalignments of the host-graft interface is highly dependent on the misalignment orientation with respect to the metal plate. For some misalignment orientations, tangential micromotions of contact interfaces exceeded alert thresholds. When the angle of the taper-fit host-graft junction is changed from 10° to 30° and the results obtained are compared with the planar case, the overall stiffness is almost preserved, the bone strains are almost unchanged with safety factors higher than five, and full contact closure around the host-graft junction is achieved at 20°. Similarly, contact pressures decrease almost linearly with a 20% decrease at 30°. The host-graft micro motions are almost unchanged in both value and distribution up to 20° and never exceed the warning threshold of 50 μm. CONCLUSIONS The present in silico study developed quantitative biomechanical evidence that an osteotomy performed with attention to the perpendicularity of the cut planes is needed to reduce the risk of mismatch and possible complications of long bone reconstructions, and that a new concept of a taper-fit junction may improve the biomechanical environment of the interface between the graft and the host bone. The optimal taper-fit configuration is suggested to be around a 20° taper angle. These results will serve as an input to conduct exvivo experiments to further corroborate the proposed taper-fit junction concept and to refine its surgical implementation.
Collapse
Affiliation(s)
- Enrico Schileo
- Bioengineering and Computing Laboratory, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, IT, Italy
| | - Pietro Feltri
- Orthopaedic and Traumatology Unit, Ospedale Regionale di Lugano, EOC, 6900 Lugano, CH Switzerland.
| | - Fulvia Taddei
- Bioengineering and Computing Laboratory, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, IT, Italy
| | | | - Alessandro Di Martino
- Second Orthopaedic and Traumatologic Clinic, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, IT, Italy
| | - Giuseppe Filardo
- Applied and Translational Research Center, IRCCS Istituto Ortopedico Rizzoli, 40136 Bologna, IT, Italy
| |
Collapse
|
32
|
Wu Y, Loaiza J, Banerji R, Blouin O, Morgan E. Structure-function relationships of the human vertebral endplate. JOR Spine 2021; 4:e1170. [PMID: 34611592 PMCID: PMC8479528 DOI: 10.1002/jsp2.1170] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/27/2021] [Revised: 07/30/2021] [Accepted: 08/19/2021] [Indexed: 11/23/2022] Open
Abstract
BACKGROUND Although deformation and fracture of the vertebral endplate have been implicated in spinal conditions such as vertebral fracture and disc degeneration, few biomechanical studies of this structure are available. The goal of this study was to quantify the mechanical behavior of the vertebral endplate. METHODS Eight-five rectangular specimens were dissected from the superior and/or inferior central endplates of human lumbar spine segments L1 to L4. Micro-computed tomography (μCT) imaging, four-point-bend testing, and ashing were performed to quantify the apparent elastic modulus and yield stress (modulus and yield stress, respectively, of the porous vertebral endplate), tissue yield stress (yield stress of the tissue of the vertebral endplate, excluding pores), ultimate strain, fracture strain, bone volume fraction (BV/TV), bone mineral density (BMD), and various measures of tissue density and composition (tissue mineral density, ash fraction, and ash density). Regression was used to assess the dependence of mechanical properties on density and composition. RESULTS Wide variations in elastic and failure properties, and in density and tissue composition, were observed. BMD and BV/TV were good predictors of many of the apparent-level mechanical properties, including modulus, yield stress, and in the case of the inferior vertebral endplate, failure strains. Similar values of the mechanical properties were noted between superior and inferior vertebral endplates. In contrast to the dependence of apparent stiffness and strength on BMD and BV/TV, none of the mechanical properties depended on any of the tissue-level density measurements. CONCLUSION The dependence of many of the mechanical properties of the vertebral endplate on BV/TV and BMD suggests possibilities for noninvasive assessment of how this region of the spine behaves during habitual and injurious loading. Further study of the nonmineral components of the endplate tissue is required to understand how the composition of this tissue may influence the overall mechanical behavior of the vertebral endplate.
Collapse
Affiliation(s)
- Yuanqiao Wu
- Department of Mechanical EngineeringBoston UniversityBostonMassachusettsUSA
| | - Johnfredy Loaiza
- Department of Mechanical EngineeringBoston UniversityBostonMassachusettsUSA
| | - Rohin Banerji
- Department of Biomedical EngineeringBoston UniversityBostonMassachusettsUSA
| | - Olivia Blouin
- Department of Biomedical EngineeringBoston UniversityBostonMassachusettsUSA
| | - Elise Morgan
- Department of Mechanical EngineeringBoston UniversityBostonMassachusettsUSA
- Department of Biomedical EngineeringBoston UniversityBostonMassachusettsUSA
| |
Collapse
|
33
|
Jambon-Puillet E, Piéchaud MR, Brun PT. Elastic amplification of the Rayleigh-Taylor instability in solidifying melts. Proc Natl Acad Sci U S A 2021; 118:e2020701118. [PMID: 33619177 PMCID: PMC7958244 DOI: 10.1073/pnas.2020701118] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
Abstract
The concomitant mechanical deformation and solidification of melts are relevant to a broad range of phenomena. Examples include the preparation of cotton candy, the atomization of metals, the manufacture of glass fibers, and the formation of elongated structures in volcanic eruptions known as Pele's hair. Usually, solid-like deformations during solidification are neglected as the melt is much more malleable in its initial liquid-like form. Here we demonstrate how elastic deformations in the midst of solidification, i.e., while the melt responds as a very soft solid ([Formula: see text] Pa), can lead to the formation of previously unknown periodic structures. Namely, we generate an array of droplets on a thin layer of liquid elastomer melt coated on the outside of a rotating cylinder through the Rayleigh-Taylor instability. Then, as the melt cures and goes through its gelation point, the rotation speed is increased and the drops stretch into hairs. The ongoing solidification eventually hardens the material, permanently "freezing" these elastic deformations into a patterned solid. Using experiments, simulation, and theory, we demonstrate that the formation of our two-step patterns can be rationalized when combining the tools from fluid mechanics, elasticity, and statistics. Our study therefore provides a framework to analyze multistep pattern formation processes and harness them to assemble complex materials.
Collapse
Affiliation(s)
- Etienne Jambon-Puillet
- Department of Chemical and Biological Engineering, Princeton University, Princeton, NJ 08540
| | - Matthieu Royer Piéchaud
- Department of Chemical and Biological Engineering, Princeton University, Princeton, NJ 08540
| | - P-T Brun
- Department of Chemical and Biological Engineering, Princeton University, Princeton, NJ 08540
| |
Collapse
|
34
|
Peralta L, Maeztu Redin JD, Fan F, Cai X, Laugier P, Schneider J, Raum K, Grimal Q. Bulk Wave Velocities in Cortical Bone Reflect Porosity and Compression Strength. ULTRASOUND IN MEDICINE & BIOLOGY 2021; 47:799-808. [PMID: 33341302 DOI: 10.1016/j.ultrasmedbio.2020.11.012] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/21/2020] [Revised: 11/16/2020] [Accepted: 11/16/2020] [Indexed: 06/12/2023]
Abstract
The goal of this study was to evaluate whether ultrasonic velocities in cortical bone can be considered as a proxy for mechanical quality of cortical bone tissue reflected by porosity and compression strength. Micro-computed tomography, compression mechanical testing and resonant ultrasound spectroscopy were used to assess, respectively, porosity, strength and velocity of bulk waves of both shear and longitudinal polarisations propagating along and perpendicular to osteons, in 92 cortical bone specimens from tibia and femur of elderly human donors. All velocities were significantly associated with strength (r = 0.65-0.83) and porosity (r = -0.64 to -0.77). Roughly, according to linear regression models, a decrease in velocity of 100 m/s corresponded to a loss of 20 MPa in strength (which is approximately 10% of the largest strength value) and to an increase in porosity of 5%. These results provide a rationale for the in vivo measurement of one or several velocities for the diagnosis of bone fragility.
Collapse
Affiliation(s)
- Laura Peralta
- Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France; Department of Biomedical Engineering, School of Biomedical Engineering & Imaging Sciences, Kings College London, London, United Kingdom.
| | - Juan Deyo Maeztu Redin
- Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France
| | - Fan Fan
- Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France; Beijing Advanced Innovation Center for Biomedical Engineering, School of Biological Science and Medical Engineering, Beihang University, Beijing, China
| | - Xiran Cai
- Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France
| | - Pascal Laugier
- Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France
| | - Johannes Schneider
- Berlin-Brandenburg School for Regenerative Therapies, Charit-Universittsmedizin Berlin, Berlin, Germany
| | - Kay Raum
- Berlin-Brandenburg School for Regenerative Therapies, Charit-Universittsmedizin Berlin, Berlin, Germany
| | - Quentin Grimal
- Sorbonne Universite, INSERM, CNRS, Laboratoire d'lmagerie Biomedicale, LIB, F-75006 Paris, France
| |
Collapse
|
35
|
Eden E, Buldur B, Duruk G, Ezberci S. Web-based dental trauma database using Eden Baysal dental trauma index: a turkish multicenter study. Eur Oral Res 2021; 55:21-27. [PMID: 33937758 PMCID: PMC8055256 DOI: 10.26650/eor.20210077] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Abstract
Purpose To describe the prevalence and pattern of traumatic dental injuries (TDIs) among Turkish children in a web-based and multicenter design using Eden Baysal Dental Trauma Index (EBDTI). Materials and methods The study sample consisted dental trauma patients aging 1-15 years and a webbased form was developed and used to record the information of the patients' clinical and radiographic findings including EBDTI. The obtained data also included patient gender, age at the initial date of trauma, date of trauma, cause of injury and emergency treatment. Data were analyzed using Pearson Chi-square and Fisher's exact tests. Results A total of 280 traumatized teeth in 252 patients were evaluated. Dental trauma was seen more in boys and 7-10 years age group (p<0.05). There were significant differences between permanent and deciduous teeth with regard to uncomplicated and complicated crown fracture rate (p<0.05). The root fractures were mostly located at the apical third of the root in both dentitions. Conclusion TDI was associated with age, gender, and type of dental trauma. EDBTI provided easy and proper recording of multiple dental injuries and maturity of the apex and it was found to be a very useful tool to facilitate online recordings of dental injuries.
Collapse
Affiliation(s)
- Ece Eden
- Department of Pediatric Dentistry, Faculty of Dentistry,Ege University, İzmir, Turkey
| | - Burak Buldur
- Department of Pediatric Dentistry, Faculty of Dentistry,Cumhuriyet University, Sivas,Turkey
| | - Gulsum Duruk
- Department of Pediatric Dentistry, Faculty of Dentistry,Inonu University, Malatya,Turkey
| | - Sibel Ezberci
- Department of Pediatric Dentistry, Faculty of Dentistry,Uşak University, Uşak,Turkey
| |
Collapse
|
36
|
Paknahad A, Goudarzi M, Kucko NW, Leeuwenburgh SC, Sluys LJ. Calcium phosphate cement reinforced with poly (vinyl alcohol) fibers: An experimental and numerical failure analysis. Acta Biomater 2021; 119:458-471. [PMID: 33164819 DOI: 10.1016/j.actbio.2020.10.014] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 10/07/2020] [Accepted: 10/09/2020] [Indexed: 10/23/2022]
Abstract
Calcium phosphate cements (CPCs) have been widely used during the past decades as biocompatible bone substitution in maxillofacial, oral and orthopedic surgery. CPCs are injectable and are chemically resemblant to the mineral phase of native bone. Nevertheless, their low fracture toughness and high brittleness reduce their clinical applicability to weakly loaded bones. Reinforcement of CPC matrix with polymeric fibers can overcome these mechanical drawbacks and significantly enhance their toughness and strength. Such fiber-reinforced calcium phosphate cements (FRCPCs) have the potential to act as advanced bone substitute in load-bearing anatomical sites. This work achieves integrated experimental and numerical characterization of the mechanical properties of FRCPCs under bending and tensile loading. To this end, a 3-D numerical gradient enhanced damage model combined with a dimensionally-reduced fiber model are employed to develop a computational model for material characterization and to simulate the failure process of fiber-reinforced CPC matrix based on experimental data. In addition, an advanced interfacial constitutive law, derived from micromechanical pull-out tests, is used to represent the interaction between the polymeric fiber and CPC matrix. The presented computational model is successfully validated with the experimental results and offers a firm basis for further investigations on the development of numerical and experimental analysis of fiber-reinforced bone cements.
Collapse
|
37
|
McKinsey K, Thompson A, Bertocci G. Investigation of femur fracture potential in common pediatric falls using finite element analysis. Comput Methods Biomech Biomed Engin 2020; 24:517-526. [PMID: 33115286 DOI: 10.1080/10255842.2020.1837119] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/23/2022]
Abstract
A finite element (FE) model of an 11-month-old child's femur was developed to evaluate fracture risk in short-distance feet-first falls and bed falls. Pediatric material properties were applied to the FE model. Femur loading was derived from previously conducted fall experiments using a child surrogate where fall conditions (e.g., fall height, impact surface) were varied. Fracture thresholds based on principal stress and strain were used to examine potential for fracture. Peak stress/strain were significantly greater for feet-first falls from greater heights and onto harder impact surfaces. Feet-first falls exceeded some, but not all fracture thresholds. Bed falls did not exceed any fracture thresholds.
Collapse
Affiliation(s)
- Keyonna McKinsey
- Department of Bioengineering, University of Louisville, Louisville, KY, USA
| | - Angela Thompson
- Department of Engineering Fundamentals, University of Louisville, Louisville, KY, USA
| | - Gina Bertocci
- Department of Bioengineering, University of Louisville, Louisville, KY, USA
| |
Collapse
|
38
|
Yong KW, Choi JR, Choi JY, Cowie AC. Recent Advances in Mechanically Loaded Human Mesenchymal Stem Cells for Bone Tissue Engineering. Int J Mol Sci 2020; 21:5816. [PMID: 32823645 PMCID: PMC7461207 DOI: 10.3390/ijms21165816] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2020] [Revised: 08/06/2020] [Accepted: 08/12/2020] [Indexed: 12/14/2022] Open
Abstract
Large bone defects are a major health concern worldwide. The conventional bone repair techniques (e.g., bone-grafting and Masquelet techniques) have numerous drawbacks, which negatively impact their therapeutic outcomes. Therefore, there is a demand to develop an alternative bone repair approach that can address the existing drawbacks. Bone tissue engineering involving the utilization of human mesenchymal stem cells (hMSCs) has recently emerged as a key strategy for the regeneration of damaged bone tissues. However, the use of tissue-engineered bone graft for the clinical treatment of bone defects remains challenging. While the role of mechanical loading in creating a bone graft has been well explored, the effects of mechanical loading factors (e.g., loading types and regime) on clinical outcomes are poorly understood. This review summarizes the effects of mechanical loading on hMSCs for bone tissue engineering applications. First, we discuss the key assays for assessing the quality of tissue-engineered bone grafts, including specific staining, as well as gene and protein expression of osteogenic markers. Recent studies of the impact of mechanical loading on hMSCs, including compression, perfusion, vibration and stretching, along with the potential mechanotransduction signalling pathways, are subsequently reviewed. Lastly, we discuss the challenges and prospects of bone tissue engineering applications.
Collapse
Affiliation(s)
- Kar Wey Yong
- Department of Surgery, Faculty of Medicine & Dentistry, University of Alberta, Edmonton, AB T6G 2R3, Canada
| | - Jane Ru Choi
- Department of Mechanical Engineering, University of British Columbia, 2054-6250 Applied Science Lane, Vancouver, BC V6T 1Z4, Canada
- Centre for Blood Research, Life Sciences Centre, University of British Columbia, 2350 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
| | - Jean Yu Choi
- Ninewells Hospital & Medical School, Dundee, Scotland DD1 5EH, UK; (J.Y.C.); (A.C.C.)
| | - Alistair C. Cowie
- Ninewells Hospital & Medical School, Dundee, Scotland DD1 5EH, UK; (J.Y.C.); (A.C.C.)
| |
Collapse
|
39
|
Falcinelli C, Whyne C. Image-based finite-element modeling of the human femur. Comput Methods Biomech Biomed Engin 2020; 23:1138-1161. [PMID: 32657148 DOI: 10.1080/10255842.2020.1789863] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Fracture is considered a critical clinical endpoint in skeletal pathologies including osteoporosis and bone metastases. However, current clinical guidelines are limited with respect to identifying cases at high risk of fracture, as they do not account for many mechanical determinants that contribute to bone fracture. Improving fracture risk assessment is an important area of research with clear clinical relevance. Patient-specific numerical musculoskeletal models generated from diagnostic images are widely used in biomechanics research and may provide the foundation for clinical tools used to quantify fracture risk. However, prior to clinical translation, in vitro validation of predictions generated from such numerical models is necessary. Despite adopting radically different models, in vitro validation of image-based finite element (FE) models of the proximal femur (predicting strains and failure loads) have shown very similar, encouraging levels of accuracy. The accuracy of such in vitro models has motivated their application to clinical studies of osteoporotic and metastatic fractures. Such models have demonstrated promising but heterogeneous results, which may be explained by the lack of a uniform strategy with respect to FE modeling of the human femur. This review aims to critically discuss the state of the art of image-based femoral FE modeling strategies, highlighting principal features and differences among current approaches. Quantitative results are also reported with respect to the level of accuracy achieved from in vitro evaluations and clinical applications and are used to motivate the adoption of a standardized approach/workflow for image-based FE modeling of the femur.
Collapse
Affiliation(s)
- Cristina Falcinelli
- Orthopaedic Biomechanics Laboratory, Sunnybrook Research Institute, Toronto, Canada
| | - Cari Whyne
- Orthopaedic Biomechanics Laboratory, Sunnybrook Research Institute, Toronto, Canada
| |
Collapse
|
40
|
Schileo E, Pitocchi J, Falcinelli C, Taddei F. Cortical bone mapping improves finite element strain prediction accuracy at the proximal femur. Bone 2020; 136:115348. [PMID: 32240847 DOI: 10.1016/j.bone.2020.115348] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 09/23/2019] [Revised: 03/17/2020] [Accepted: 03/27/2020] [Indexed: 11/28/2022]
Abstract
Despite evidence of the biomechanical role of cortical bone, current state of the art finite element models of the proximal femur built from clinical CT data lack a subject-specific representation of the bone cortex. Our main research hypothesis is that the subject-specific modelling of cortical bone layer from CT images, through a deconvolution procedure known as Cortical Bone Mapping (CBM, validated for cortical thickness and density estimates) can improve the accuracy of CT-based FE models of the proximal femur, currently limited by partial volume artefacts. Our secondary hypothesis is that a careful choice of cortical-specific density-elasticity relationship may improve model accuracy. We therefore: (i) implemented a procedure to include subject-specific CBM estimates of both cortical thickness and density in CT-based FE models. (ii) defined alternative models that included CBM estimates and featured a cortical-specific or an independently optimised density-elasticity relationship. (iii) tested our hypotheses in terms of elastic strain estimates and failure load and location prediction, by comparing with a published cohort of 14 femurs, where strain and strength in stance and fall loading configuration were experimentally measured, and estimated through reference FE models that did not explicitly model the cortical compartment. Our findings support the main hypothesis: an explicit modelling of the proximal femur cortical bone layer including CBM estimates of cortical bone thickness and density increased the FE strains prediction, mostly by reducing peak errors (average error reduced by 30%, maximum error and 95th percentile of error distribution halved) and especially when focusing on the femoral neck locations (all error metrics at least halved). We instead rejected the secondary hypothesis: changes in cortical density-elasticity relationship could not improve validation performances. From these improved baseline strain estimates, further work is needed to achieve accurate strength predictions, as models incorporating cortical thickness and density produced worse estimates of failure load and equivalent estimates of failure location when compared to reference models. In summary, we recommend including local estimates of cortical thickness and density in FE models to estimate bone strains in physiological conditions, and especially when designing exercise studies to promote bone strength.
Collapse
Affiliation(s)
- Enrico Schileo
- Bioengineering and Computing Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy.
| | - Jonathan Pitocchi
- Materialise N.V., Heverlee, Belgium; Multiscale in Mechanical and Biological Engineering (M2BE), University of Zaragoza, Zaragoza, Spain; Biomechanics Section, KU Leuven, Leuven, Belgium
| | | | - Fulvia Taddei
- Bioengineering and Computing Laboratory, IRCCS Istituto Ortopedico Rizzoli, Bologna, Italy
| |
Collapse
|
41
|
Fleps I, Bahaloo H, Zysset PK, Ferguson SJ, Pálsson H, Helgason B. Empirical relationships between bone density and ultimate strength: A literature review. J Mech Behav Biomed Mater 2020; 110:103866. [PMID: 32957183 DOI: 10.1016/j.jmbbm.2020.103866] [Citation(s) in RCA: 30] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2020] [Revised: 05/06/2020] [Accepted: 05/17/2020] [Indexed: 02/02/2023]
Abstract
INTRODUCTION Ultimate strength-density relationships for bone have been reported with widely varying results. Reliable bone strength predictions are crucial for many applications that aim to assess bone failure. Bone density and bone morphology have been proposed to explain most of the variance in measured bone strength. If this holds true, it could lead to the derivation of a single ultimate strength-density-morphology relationship for all anatomical sites. METHODS All relevant literature was reviewed. Ultimate strength-density relationships derived from mechanical testing of human bone tissue were included. The reported relationships were translated to ultimate strength-apparent density relationships and normalized with respect to strain rate. Results were grouped based on bone tissue type (cancellous or cortical), anatomical site, and loading mode (tension vs. compression). When possible, the relationships were compared to existing ultimate strength-density-morphology relationships. RESULTS Relationships that considered bone density and morphology covered the full spectrum of eight-fold inter-study difference in reported compressive ultimate strength-density relationships for trabecular bone. This was true for studies that tested specimens in different loading direction and tissue from different anatomical sites. Sparse data was found for ultimate strength-density relationships in tension and for cortical bone properties transverse to the main loading axis of the bone. CONCLUSIONS Ultimate strength-density-morphology relationships could explain measured strength across anatomical sites and loading directions. We recommend testing of bone specimens in other directions than along the main trabecular alignment and to include bone morphology in studies that investigate bone material properties. The lack of tensile strength data did not allow for drawing conclusions on ultimate strength-density-morphology relationships. Further studies are needed. Ideally, these studies would investigate both tensile and compressive strength-density relationships, including morphology, to close this gap and lead to more accurate evaluation of bone failure.
Collapse
Affiliation(s)
- Ingmar Fleps
- Institute for Biomechanics, ETH-Zürich, Zürich, Switzerland.
| | - Hassan Bahaloo
- Faculty of Industrial Engineering, Mechanical Engineering and Computer Science, School of Engineering and Natural Sciences, University of Iceland, Reykjavik, Iceland
| | - Philippe K Zysset
- ARTORG Center for Biomedical Engineering Research, University of Bern, Bern, Switzerland
| | | | - Halldór Pálsson
- Faculty of Industrial Engineering, Mechanical Engineering and Computer Science, School of Engineering and Natural Sciences, University of Iceland, Reykjavik, Iceland
| | | |
Collapse
|
42
|
Epidemiology and Imaging Classification of Pediatric Cervical Spine Injuries: 12-Year Experience at a Level 1 Trauma Center. AJR Am J Roentgenol 2020; 214:1359-1368. [DOI: 10.2214/ajr.19.22095] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
43
|
Nouri F, Ghasemi SH, Lee JY. System reliability analysis of the scoliosis disorder. BMC Musculoskelet Disord 2020; 21:199. [PMID: 32234029 PMCID: PMC7110658 DOI: 10.1186/s12891-020-03230-4] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/14/2019] [Accepted: 03/24/2020] [Indexed: 08/24/2023] Open
Abstract
BACKGROUND Scoliosis is a spine abnormal deviation, which is an idiopathic disorder among children and adolescents. As a matter of the fact, distribution of loads on the patient's spine and load-carrying capacity of the vertebral column are both random variables. Therefore, the probabilistic approach may consider as a sophisticated method to deal with this problem. METHOD Reliability analysis is a probabilistic-based approach to consider the uncertainties of load and resistance of the vertebral column. The main contribution of this paper is to compare the reliability level of a normal and scoliosis spinal. To do so, the numerical analyses associated with the inherent random parameters of bones and applied load are performed. Then, the reliability indices for all vertebrae and discs are determined. Accordingly, as the main innovation of this paper, the system reliability indices of the spinal column for both normal and damaged backbone systems are represented. RESULTS Based on the required reliability index for normal spinal curvature the target system reliability level for scoliosis disorder is proposed. CONCLUSION Since the proposed target reliability index is based on the strength limit state of the vertebral column, it can be considered as a reliability level for any proposed treatment approaches.
Collapse
Affiliation(s)
- Fatemeh Nouri
- Department of Civil Engineering, Qazvin Branch, Islamic Azad University, Qazvin, 14778-93855, Iran
| | - S Hooman Ghasemi
- Department of Civil Engineering, Qazvin Branch, Islamic Azad University, Qazvin, 14778-93855, Iran. .,Department of Civil and Environmental Engineering, Washington State University, Pullman, USA.
| | - Ji Yun Lee
- Department of Civil and Environmental Engineering, Washington State University, Pullman, USA
| |
Collapse
|
44
|
Loundagin LL, Haider IT, Cooper DM, Edwards WB. Association between intracortical microarchitecture and the compressive fatigue life of human bone: A pilot study. Bone Rep 2020; 12:100254. [PMID: 32258250 PMCID: PMC7110329 DOI: 10.1016/j.bonr.2020.100254] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/29/2019] [Revised: 02/26/2020] [Accepted: 03/02/2020] [Indexed: 11/18/2022] Open
Abstract
Many mechanical properties of cortical bone are largely governed by the underlying microarchitecture; however, the influence of microarchitecture on the fatigue life of bone is poorly understood. Furthermore, imaging-based studies investigating intracortical microarchitecture may expose bone samples to large doses of radiation that may compromise fatigue resistance. The purpose of this pilot study was to 1) investigate the relationship between intracortical microarchitecture and the fatigue life of human bone in compression and 2) examine the effects of synchrotron irradiation on fatigue life measurements. Cortical samples were prepared from the femoral and tibial shafts of three cadaveric donors. A subset of samples was imaged using synchrotron X-ray microCT to quantify microarchitecture, including porosity, canal diameter, lacunar density, lacunar volume, and lacunar orientation. A second group of control samples was not imaged and used only for mechanical testing. Fatigue life was quantified by cyclically loading both groups in zero-compression until failure. Increased porosity and larger canal diameter were both logarithmically related to a shorter fatigue life, whereas lacunar density demonstrated a positive linear relationship with fatigue life (r2 = 45–73%, depending on measure). Irradiation from microCT scanning reduced fatigue life measurements by 91%, but relationships with microarchitecture measurements remained. Additional research is needed to support the findings of this pilot study and fully establish the relationship between intracortical microarchitecture and the compressive fatigue life of bone. Increased porosity and larger canal diameters were associated with a shorter compressive fatigue life. A higher lacunar density was related to a longer compressive fatigue life. Irradiation from synchrotron X-ray microCT scanning reduced fatigue life by 91%. The influence of microarchitecture on fatigue life exhibited similar trends for both irradiated and non-irradiated bone.
Collapse
Affiliation(s)
- Lindsay L. Loundagin
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, 2500 University Drive NW, Calgary, AB T2N 1N4, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, 3280 Hospital Dr NW, Calgary, AB T2N 4Z6, Canada
- Corresponding author at: Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, 2500 University Drive NW, Calgary, AB T2N 1N4, Canada.
| | - Ifaz T. Haider
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, 2500 University Drive NW, Calgary, AB T2N 1N4, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, 3280 Hospital Dr NW, Calgary, AB T2N 4Z6, Canada
| | - David M.L. Cooper
- Department of Anatomy, Physiology and Pharmacology, University of Saskatchewan, 105 Administration Place, Saskatoon, SK S7N 5A2, Canada
| | - W. Brent Edwards
- Human Performance Laboratory, Faculty of Kinesiology, University of Calgary, 2500 University Drive NW, Calgary, AB T2N 1N4, Canada
- McCaig Institute for Bone and Joint Health, University of Calgary, 3280 Hospital Dr NW, Calgary, AB T2N 4Z6, Canada
| |
Collapse
|
45
|
3D-printed PLA/HA composite structures as synthetic trabecular bone: A feasibility study using fused deposition modeling. J Mech Behav Biomed Mater 2019; 103:103608. [PMID: 32090935 DOI: 10.1016/j.jmbbm.2019.103608] [Citation(s) in RCA: 54] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/27/2019] [Revised: 12/16/2019] [Accepted: 12/25/2019] [Indexed: 11/22/2022]
Abstract
Additive manufacturing has significant advantages, in the biomedical field, allowing for customized medical products where complex architectures can be achieved directly. While additive manufacturing can be used to fabricate synthetic bone models, this approach is limited by the printing resolution, at the level of the trabecular bone architecture. Therefore, the aim of this study was to evaluate the possibilities of using fused deposition modeling (FDM) to this end. To better mimic real bone, both in terms of mechanical properties and biodegradability, a composite of degradable polymer, poly(lactic acid) (PLA), and hydroxyapatite (HA) was used as the filament. Three PLA/HA composite formulations with 5-10-15 wt% HA were evaluated, and scaled up human trabecular bone models were printed using these materials. Morphometric and mechanical properties of the printed models were evaluated by micro-computed tomography, compression and screw pull out tests. It was shown that the trabecular architecture could be reproduced with FDM and PLA by applying a scaling factor of 2-4. The incorporation of HA particles reduced the printing accuracy, with respect to morphology, but showed potential for enhancement of the mechanical properties. The scaled-up models displayed comparable, or slightly enhanced, strength compared to the commonly used polymeric foam synthetic bone models (i.e. Sawbones). Reproducing the trabecular morphology by 3D printed PLA/HA composites appears to be a promising strategy for synthetic bone models, when high printed resolution can be achieved.
Collapse
|
46
|
Lefèvre E, Farlay D, Bala Y, Subtil F, Wolfram U, Rizzo S, Baron C, Zysset P, Pithioux M, Follet H. Compositional and mechanical properties of growing cortical bone tissue: a study of the human fibula. Sci Rep 2019; 9:17629. [PMID: 31772277 PMCID: PMC6879611 DOI: 10.1038/s41598-019-54016-1] [Citation(s) in RCA: 26] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Accepted: 10/08/2019] [Indexed: 01/28/2023] Open
Abstract
Human cortical bone contains two types of tissue: osteonal and interstitial tissue. Growing bone is not well-known in terms of its intrinsic material properties. To date, distinctions between the mechanical properties of osteonal and interstitial regions have not been investigated in juvenile bone and compared to adult bone in a combined dataset. In this work, cortical bone samples obtained from fibulae of 13 juveniles patients (4 to 18 years old) during corrective surgery and from 17 adult donors (50 to 95 years old) were analyzed. Microindentation was used to assess the mechanical properties of the extracellular matrix, quantitative microradiography was used to measure the degree of bone mineralization (DMB), and Fourier transform infrared microspectroscopy was used to evaluate the physicochemical modifications of bone composition (organic versus mineral matrix). Juvenile and adult osteonal and interstitial regions were analyzed for DMB, crystallinity, mineral to organic matrix ratio, mineral maturity, collagen maturity, carbonation, indentation modulus, indicators of yield strain and tissue ductility using a mixed model. We found that the intrinsic properties of the juvenile bone were not all inferior to those of the adult bone. Mechanical properties were also differently explained in juvenile and adult groups. The study shows that different intrinsic properties should be used in case of juvenile bone investigation.
Collapse
Affiliation(s)
- Emmanuelle Lefèvre
- Aix-Marseille Univ., CNRS, ISM Inst Movement Sci, Marseille, France.,Department of Orthopaedics and Traumatology, Institute for Locomotion, APHM, Sainte-Marguerite Hospital, Marseille, France
| | - Delphine Farlay
- Univ Lyon, Université Claude Bernard Lyon 1, INSERM, Lyos UMR1033, F69622, Lyon, France
| | - Yohann Bala
- Univ Lyon, Université Claude Bernard Lyon 1, INSERM, Lyos UMR1033, F69622, Lyon, France.,Laboratoire Vibrations Acoustique, INSA Lyon, Campus LyonTech la Doua, F69621, Villeurbanne Cedex, France
| | - Fabien Subtil
- Univ Lyon, Université Claude Bernard Lyon 1, Equipe Biostatistique Santé - LBBE, F69003, Lyon, France
| | - Uwe Wolfram
- School of Engineering and Physical Science, Heriot-Watt University, Edinburgh, United Kingdom
| | - Sébastien Rizzo
- Univ Lyon, Université Claude Bernard Lyon 1, INSERM, Lyos UMR1033, F69622, Lyon, France
| | - Cécile Baron
- Aix-Marseille Univ., CNRS, ISM Inst Movement Sci, Marseille, France.,Department of Orthopaedics and Traumatology, Institute for Locomotion, APHM, Sainte-Marguerite Hospital, Marseille, France
| | - Philippe Zysset
- ARTORG Center for biomedical engineering research, University of Bern, Bern, Switzerland
| | - Martine Pithioux
- Aix-Marseille Univ., CNRS, ISM Inst Movement Sci, Marseille, France.,Department of Orthopaedics and Traumatology, Institute for Locomotion, APHM, Sainte-Marguerite Hospital, Marseille, France
| | - Hélène Follet
- Univ Lyon, Université Claude Bernard Lyon 1, INSERM, Lyos UMR1033, F69622, Lyon, France.
| |
Collapse
|
47
|
Zhong G, Vaezi M, Mei X, Liu P, Yang S. Strategy for Controlling the Properties of Bioactive Poly-Ether-Ether-Ketone/Hydroxyapatite Composites for Bone Tissue Engineering Scaffolds. ACS OMEGA 2019; 4:19238-19245. [PMID: 31763547 PMCID: PMC6868901 DOI: 10.1021/acsomega.9b02572] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 08/11/2019] [Accepted: 10/23/2019] [Indexed: 06/10/2023]
Abstract
A strategy for the preparation of bioactive poly-ether-ether-ketone/hydroxyapatite (PEEK/HA) composites was proposed in this study with the aim of controlling the biological and mechanical properties of different parts of the composites. The strategy integrated solvent-based extrusion freeforming 3D printing technology in order to print high-resolution HA scaffolds and compression molding processes for the production of bioactive PEEK/HA composites. To this end, an optimized model, established using response surface methodology, was employed to optimize the extrusion process parameters on the basis of accurate characterization of the extrusion pressure, and the effects of the filament/pore sizes on the PEEK infiltration depth into the HA scaffold were investigated. The results of scanning electron microscopy and computed tomography analyses revealed that the PEEK/HA composites exhibited a uniform microstructure and a good interface between the HA filaments and the PEEK matrix following the optimization of the process parameters. The HA scaffolds were fully infiltrated by PEEK in both vertical and lateral directions with an infiltration depth of 3 mm while maintaining the HA network structure and uniformity. The biological and mechanical performance test results validated that the PEEK/HA composites possessed excellent biocompatibility as well as yields and compressive strengths within the range of human cortical bone suitable for load-bearing applications.
Collapse
Affiliation(s)
- Gaoyan Zhong
- College
of Engineering, Nanjing Agricultural University, Nanjing 210031, Jiangsu, China
- Faculty
of Engineering and the Environment, University
of Southampton, Southampton SO17 1BJ, Hampshire, U.K.
- State
Key Laboratory of Materials Processing and Die & Mould Technology, Huazhong University of Science and Technology, Wuhan 430074, Hubei, China
| | - Mohammad Vaezi
- Faculty
of Engineering and the Environment, University
of Southampton, Southampton SO17 1BJ, Hampshire, U.K.
- Department
of Mechanical Engineering and Marine Technology, University of Rostock, Rostock 18059, Germany
- Department
of Mechanical Engineering, Babol Noshirvani
University of Technology, Babol 4714871167, Mazandaran, Iran
| | - Xinliang Mei
- College
of Engineering, Nanjing Agricultural University, Nanjing 210031, Jiangsu, China
| | - Ping Liu
- College
of Engineering, Nanjing Agricultural University, Nanjing 210031, Jiangsu, China
| | - Shoufeng Yang
- College
of Engineering, Nanjing Agricultural University, Nanjing 210031, Jiangsu, China
- Faculty
of Engineering and the Environment, University
of Southampton, Southampton SO17 1BJ, Hampshire, U.K.
| |
Collapse
|
48
|
The status and challenges of replicating the mechanical properties of connective tissues using additive manufacturing. J Mech Behav Biomed Mater 2019; 103:103544. [PMID: 32090944 DOI: 10.1016/j.jmbbm.2019.103544] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/14/2019] [Revised: 10/29/2019] [Accepted: 11/16/2019] [Indexed: 01/23/2023]
Abstract
The ability to fabricate complex structures via precise and heterogeneous deposition of biomaterials makes additive manufacturing (AM) a leading technology in the creation of implants and tissue engineered scaffolds. Connective tissues (CTs) remain attractive targets for manufacturing due to their "simple" tissue compositions that, in theory, are replicable through choice of biomaterial(s) and implant microarchitecture. Nevertheless, characterisation of the mechanical and biological functions of 3D printed constructs with respect to their host tissues is often limited and remains a restriction towards their translation into clinical practice. This review aims to provide an update on the current status of AM to mimic the mechanical properties of CTs, with focus on arterial tissue, articular cartilage and bone, from the perspective of printing platforms, biomaterial properties, and topological design. Furthermore, the grand challenges associated with the AM of CT replacements and their subsequent regulatory requirements are discussed to aid further development of reliable and effective implants.
Collapse
|
49
|
Benca E, Synek A, Amini M, Kainberger F, Hirtler L, Windhager R, Mayr W, Pahr DH. QCT-based finite element prediction of pathologic fractures in proximal femora with metastatic lesions. Sci Rep 2019; 9:10305. [PMID: 31311994 PMCID: PMC6635505 DOI: 10.1038/s41598-019-46739-y] [Citation(s) in RCA: 27] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/29/2018] [Accepted: 07/04/2019] [Indexed: 11/17/2022] Open
Abstract
Predicting pathologic fractures in femora with metastatic lesions remains a clinical challenge. Currently used guidelines are inaccurate, especially to predict non-impeding fractures. This study evaluated the ability of a nonlinear quantitative computed tomography (QCT)-based homogenized voxel finite element (hvFE) model to predict patient-specific pathologic fractures. The hvFE model was generated highly automated from QCT images of human femora. The femora were previously loaded in a one-legged stance setup in order to assess stiffness, failure load, and fracture location. One femur of each pair was tested in its intact state, while the contralateral femur included a simulated lesion on either the superolateral- or the inferomedial femoral neck. The hvFE model predictions of the stiffness (0.47 < R2 < 0.94), failure load (0.77 < R2 < 0.98), and exact fracture location (68%) were in good agreement with the experimental data. However, the model underestimated the failure load by a factor of two. The hvFE models predicted significant differences in stiffness and failure load for femora with superolateral- and inferomedial lesions. In contrast, standard clinical guidelines predicted identical fracture risk for both lesion sites. This study showed that the subject-specific QCT-based hvFE model could predict the effect of metastatic lesions on the biomechanical behaviour of the proximal femur with moderate computational time and high level of automation and could support treatment strategy in patients with metastatic bone disease.
Collapse
Affiliation(s)
- Emir Benca
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, 1090, Vienna, Austria.
| | - Alexander Synek
- Institute for Lightweight Design and Structural Biomechanics, TU Wien, 1060, Vienna, Austria
| | - Morteza Amini
- Institute for Lightweight Design and Structural Biomechanics, TU Wien, 1060, Vienna, Austria
| | - Franz Kainberger
- Department of Radiology, Medical University of Vienna, 1090, Vienna, Austria
| | - Lena Hirtler
- Division of Anatomy, Center for Anatomy and Cell Biology, Medical University of Vienna, 1090, Vienna, Austria
| | - Reinhard Windhager
- Department of Orthopedics and Trauma Surgery, Medical University of Vienna, 1090, Vienna, Austria
| | - Winfried Mayr
- Center for Medical Physics and Biomedical Engineering, Medical University of Vienna, 1090, Vienna, Austria
| | - Dieter H Pahr
- Institute for Lightweight Design and Structural Biomechanics, TU Wien, 1060, Vienna, Austria
| |
Collapse
|
50
|
Bunyamin A, Björkman K, Kawalilak C, Hosseinitabatabaei S, Teare A, Johnston J, Kontulainen S. Reliability of Annual Changes and Monitoring Time Intervals for Bone Strength, Size, Density, and Microarchitectural Development at the Distal Radius and Tibia in Children: A 1-Year HR-pQCT Follow-Up. J Bone Miner Res 2019; 34:1297-1305. [PMID: 30730590 DOI: 10.1002/jbmr.3693] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/06/2018] [Revised: 10/05/2018] [Accepted: 01/02/2019] [Indexed: 11/07/2022]
Abstract
High-resolution peripheral quantitative computed tomography (HR-pQCT) imaging, together with computational finite element analysis (FEA), offers an attractive, noninvasive tool to quantify bone strength development in pediatric studies. Evidence of annual changes and errors in repeated HR-pQCT measures is limited, and time intervals required to reliably capture changes in children's bone strength or microarchitecture have not yet been defined. Our objectives were: (1) to quantify annual changes in bone strength and microarchitectural properties; (2) to define precision errors for pediatric bone strength outcomes; (3) to characterize annual changes in contrast to pediatric precision errors; and (4) to estimate monitoring time intervals (MTIs) required to reliably characterize bone development at the distal radius and tibia. We obtained distal radius (7% of ulnar length) and tibia (8%) bone properties using HR-pQCT and FEA from 38 follow-up study participants (21 girls) at baseline (mean age 10.6 years, SD 1.7 years) and after 1 year; and from 32 precision study participants (16 girls) at baseline (mean age 11.3 years, SD 1.6 years) and after 1 week. We characterized mean annual changes (paired t tests) contrasted to pediatric precision errors (CV%RMS ) and estimated MTIs. Annual increases in bone strength, total area, cortical thickness, and density ranged between 3.0% and 25.3% and 2.4% and 15.6% at the distal radius and tibia, respectively. Precision errors for all bone strength outcomes were ≤6.8% and ≤5.1% at the distal radius and tibia, respectively, and appeared lower than annual gains in bone strength at both sites. Cortical porosity decreased 19.6% at the distal radius and 6.6% at the distal tibia; these changes exceeded respective precision errors, indicating cortical bone consolidation. MTIs ranged between 0.5 years and infinity at the distal radius and 0.5 and 5.9 years at the distal tibia. Estimated MTIs suggest that pediatric bone strength, cortical bone density, and porosity development can be reliably monitored with annual measurements. © 2019 American Society for Bone and Mineral Research.
Collapse
Affiliation(s)
- Amy Bunyamin
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK, Canada
| | - Kelsey Björkman
- College of Kinesiology, University of Saskatchewan, Saskatoon, SK, Canada
| | - Chantal Kawalilak
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK, Canada
| | | | - Adrian Teare
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK, Canada
| | - James Johnston
- Department of Mechanical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK, Canada.,Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK, Canada
| | - Saija Kontulainen
- College of Kinesiology, University of Saskatchewan, Saskatoon, SK, Canada.,Division of Biomedical Engineering, College of Engineering, University of Saskatchewan, Saskatoon, SK, Canada
| |
Collapse
|