1
|
Mohsenvand K, Carnicer A, Marmiroli B, Moradi AR. 3D integral imaging of acoustically trapped objects. Sci Rep 2024; 14:28. [PMID: 38168597 PMCID: PMC10761982 DOI: 10.1038/s41598-023-50662-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/15/2023] [Accepted: 12/22/2023] [Indexed: 01/05/2024] Open
Abstract
3D imaging provides crucial details about the objects and scenes that may not be obtained via 2D imaging methods. However, there are several applications in which the object to be 3D-imaged requires to be immobilized. The integrated digital holographic microscopy (DHM) and optical trapping (OT) system is a useful solution for such a task, but both DHM and OT are mostly suitable for microscopic specimens. Here, for the first time to the best of our knowledge and as an analogy to the DHM-OT system, we introduce integral imaging (InIm) and acoustic trapping (AT) integrated system for 3D imaging of immobilized mesoscopic and macroscopic objects. Post-processing of InIm data enables reconstructing the scene at any arbitrary plane, therefore, it re-focuses any particular depth of the object, which is a curtail task, especially when the object is trapped by AT. We demonstrate the capability of our system by simultaneous trapping and 3D imaging of single and multiple irregularly shaped objects with mm sizes.
Collapse
Affiliation(s)
- Kooshan Mohsenvand
- Department of Physics, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, 45137-66731, Iran
| | - Artur Carnicer
- Departament de Física Aplicada, Universitat de Barcelona (UB), 08028, Barcelona, Spain
| | - Benedetta Marmiroli
- Institute of Inorganic Chemistry, Graz University of Technology, 8010, Graz, Austria
| | - Ali-Reza Moradi
- Department of Physics, Institute for Advanced Studies in Basic Sciences (IASBS), Zanjan, 45137-66731, Iran.
- School of Nano Science, Institute for Research in Fundamental Sciences (IPM), Tehran, 19395-5531, Iran.
| |
Collapse
|
2
|
Rasouli R, Villegas KM, Tabrizian M. Acoustofluidics - changing paradigm in tissue engineering, therapeutics development, and biosensing. LAB ON A CHIP 2023; 23:1300-1338. [PMID: 36806847 DOI: 10.1039/d2lc00439a] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
For more than 70 years, acoustic waves have been used to screen, diagnose, and treat patients in hundreds of medical devices. The biocompatible nature of acoustic waves, their non-invasive and contactless operation, and their compatibility with wide visualization techniques are just a few of the many features that lead to the clinical success of sound-powered devices. The development of microelectromechanical systems and fabrication technologies in the past two decades reignited the spark of acoustics in the discovery of unique microscale bio applications. Acoustofluidics, the combination of acoustic waves and fluid mechanics in the nano and micro-realm, allowed researchers to access high-resolution and controllable manipulation and sensing tools for particle separation, isolation and enrichment, patterning of cells and bioparticles, fluid handling, and point of care biosensing strategies. This versatility and attractiveness of acoustofluidics have led to the rapid expansion of platforms and methods, making it also challenging for users to select the best acoustic technology. Depending on the setup, acoustic devices can offer a diverse level of biocompatibility, throughput, versatility, and sensitivity, where each of these considerations can become the design priority based on the application. In this paper, we aim to overview the recent advancements of acoustofluidics in the multifaceted fields of regenerative medicine, therapeutic development, and diagnosis and provide researchers with the necessary information needed to choose the best-suited acoustic technology for their application. Moreover, the effect of acoustofluidic systems on phenotypic behavior of living organisms are investigated. The review starts with a brief explanation of acoustofluidic principles, the different working mechanisms, and the advantages or challenges of commonly used platforms based on the state-of-the-art design features of acoustofluidic technologies. Finally, we present an outlook of potential trends, the areas to be explored, and the challenges that need to be overcome in developing acoustofluidic platforms that can echo the clinical success of conventional ultrasound-based devices.
Collapse
Affiliation(s)
- Reza Rasouli
- Department of Biomedical Engineering, Faculty of Medicine and Health Sciences, McGill University, Montreal, Quebec, Canada.
| | - Karina Martinez Villegas
- Department of Biomedical Engineering, Faculty of Medicine and Health Sciences, McGill University, Montreal, Quebec, Canada.
| | - Maryam Tabrizian
- Department of Biomedical Engineering, Faculty of Medicine and Health Sciences, McGill University, Montreal, Quebec, Canada.
- Faculty of Dental Medicine and Oral Health Sciences, McGill University, Montreal, Quebec, Canada
| |
Collapse
|
3
|
Hammarström B, Skov NR, Olofsson K, Bruus H, Wiklund M. Acoustic trapping based on surface displacement of resonance modes. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2021; 149:1445. [PMID: 33765798 DOI: 10.1121/10.0003600] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/16/2020] [Accepted: 02/08/2021] [Indexed: 06/12/2023]
Abstract
Acoustic trapping is a promising technique for aligning particles in two-dimensional arrays, as well as for dynamic manipulation of particles individually or in groups. The actuating principles used in current systems rely on either cavity modes in enclosures or complex arrangements for phase control. Therefore, available systems either require high power inputs and costly peripheral equipment or sacrifice flexibility. This work presents a different concept for acoustic trapping of particles and cells that enables dynamically defined trapping patterns inside a simple and inexpensive setup. Here, dynamic operation and dexterous trapping are realized through the use of a modified piezoelectric transducer in direct contact with the liquid sample. Physical modeling shows how the transducer induces an acoustic force potential where the conventional trapping in the axial direction is supplemented by surface displacement dependent lateral trapping. The lateral field is a horizontal array of pronounced potential minima with frequency-dependent locations. The resulting system enables dynamic arraying of levitated trapping sites at low power and can be manufactured at ultra-low cost, operated using low-cost electronics, and assembled in less than 5 min. We demonstrate dynamic patterning of particles and biological cells and exemplify potential uses of the technique for cell-based sample preparation and cell culture.
Collapse
Affiliation(s)
- Björn Hammarström
- Department of Applied Physics, KTH Royal Institute of Technology, Roslagstullsbacken 21, SE-114 21 Stockholm, Sweden
| | - Nils R Skov
- Department of Physics, Technical University of Denmark, DTU Physics Building 309, DK-2800 Kongens Lyngby, Denmark
| | - Karl Olofsson
- Department of Applied Physics, KTH Royal Institute of Technology, Roslagstullsbacken 21, SE-114 21 Stockholm, Sweden
| | - Henrik Bruus
- Department of Physics, Technical University of Denmark, DTU Physics Building 309, DK-2800 Kongens Lyngby, Denmark
| | - Martin Wiklund
- Department of Applied Physics, KTH Royal Institute of Technology, Roslagstullsbacken 21, SE-114 21 Stockholm, Sweden
| |
Collapse
|
4
|
Olofsson K, Hammarström B, Wiklund M. Ultrasonic Based Tissue Modelling and Engineering. MICROMACHINES 2018; 9:E594. [PMID: 30441752 PMCID: PMC6266922 DOI: 10.3390/mi9110594] [Citation(s) in RCA: 20] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/19/2018] [Revised: 11/06/2018] [Accepted: 11/07/2018] [Indexed: 12/19/2022]
Abstract
Systems and devices for in vitro tissue modelling and engineering are valuable tools, which combine the strength between the controlled laboratory environment and the complex tissue organization and environment in vivo. Device-based tissue engineering is also a possible avenue for future explant culture in regenerative medicine. The most fundamental requirements on platforms intended for tissue modelling and engineering are their ability to shape and maintain cell aggregates over long-term culture. An emerging technology for tissue shaping and culture is ultrasonic standing wave (USW) particle manipulation, which offers label-free and gentle positioning and aggregation of cells. The pressure nodes defined by the USW, where cells are trapped in most cases, are stable over time and can be both static and dynamic depending on actuation schemes. In this review article, we highlight the potential of USW cell manipulation as a tool for tissue modelling and engineering.
Collapse
Affiliation(s)
- Karl Olofsson
- Department of Applied Physics, KTH Royal Institute of Technology, SE-106 91 Stockholm, Sweden.
| | - Björn Hammarström
- Department of Applied Physics, KTH Royal Institute of Technology, SE-106 91 Stockholm, Sweden.
| | - Martin Wiklund
- Department of Applied Physics, KTH Royal Institute of Technology, SE-106 91 Stockholm, Sweden.
| |
Collapse
|
5
|
Liu HC, Li Y, Chen R, Jung H, Shung KK. Single-Beam Acoustic Trapping of Red Blood Cells and Polystyrene Microspheres in Flowing Red Blood Cell Saline and Plasma Suspensions. ULTRASOUND IN MEDICINE & BIOLOGY 2017; 43:852-859. [PMID: 28236533 DOI: 10.1016/j.ultrasmedbio.2016.12.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2016] [Revised: 12/01/2016] [Accepted: 12/09/2016] [Indexed: 06/06/2023]
Abstract
Single-beam acoustic tweezers (SBATs) represent a new technology for particle and cell trapping. The advantages of SBATs are their deep penetration into tissues, reduction of tissue damage and ease of application to in vivo studies. The use of these tools for applications in drug delivery in vivo must meet the following conditions: large penetration depth, strong trapping force and tissue safety. A reasonable penetration depth for SBATs in the development of in vivo applications was established in a previous study conducted in water with zero velocity. However, capturing objects in flowing fluid can provide more meaningful results. In this study, we investigated the capability of SBATs to trap red blood cells (RBCs) and polystyrene microspheres in flowing RBC suspensions. Two different types of RBC suspension were prepared in this work: an RBC phosphate-buffered saline (PBS) suspension and an RBC plasma suspension. The results indicated that SBATs successfully trapped RBCs and polystyrene microspheres in a flowing RBC PBS suspension with an average steady velocity of 1.6 cm/s in a 2-mm-diameter polyimide. Furthermore, SBATs were found able to trap RBCs in a flowing RBC PBS suspension at speeds as high as 7.9 cm/s in a polyimide tube, which is higher than the velocity in capillaries (0.03 cm/s) and approaches the velocity in arterioles and venules. Moreover, the results also indicated that polystyrene microspheres can be trapped in an RBC plasma suspension, where aggregation is observed. This work represents a step forward in using this tool in actual in vivo experimentation.
Collapse
Affiliation(s)
- Hsiao-Chuan Liu
- Department of Biomedical Engineering and NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, California, USA; Hematology and Oncology, Children's Hospital Los Angeles, Los Angeles, California, USA
| | - Ying Li
- Department of Biomedical Engineering and NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, California, USA.
| | - Ruimin Chen
- Department of Biomedical Engineering and NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, California, USA
| | - Hayong Jung
- Department of Biomedical Engineering and NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, California, USA
| | - K Kirk Shung
- Department of Biomedical Engineering and NIH Ultrasonic Transducer Resource Center, University of Southern California, Los Angeles, California, USA.
| |
Collapse
|
6
|
|
7
|
Mishra P, Hill M, Glynne-Jones P. Deformation of red blood cells using acoustic radiation forces. BIOMICROFLUIDICS 2014; 8:034109. [PMID: 25379070 PMCID: PMC4162412 DOI: 10.1063/1.4882777] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/07/2014] [Accepted: 05/29/2014] [Indexed: 05/08/2023]
Abstract
Acoustic radiation forces have been used to manipulate cells and bacteria in a number of recent microfluidic applications. The net force on a cell has been subject to careful investigation over a number of decades. We demonstrate that the radiation forces also act to deformcells. An ultrasonic standing wave field is created in a 0.1 mm glass capillary at a frequency of 7.9 MHz. Using osmotically swollen red-blood cells, we show observable deformations up to an aspect ratio of 1.35, comparable to deformations created by optical tweezing. In contrast to optical technologies, ultrasonic devices are potentially capable of deforming thousands of cells simultaneously. We create a finite element model that includes both the acoustic environment of the cell, and a model of the cell membrane subject to forces resulting from the non-linear aspects of the acoustic field. The model is found to give reasonable agreement with the experimental results, and shows that the deformation is the result of variation in an acoustic force that is directed outwards at all points on the cell membrane. We foresee applications in diagnostic devices, and in the possibility of mechanically stimulating cells to promote differentiation and physiological effects.
Collapse
Affiliation(s)
- Puja Mishra
- Engineering Sciences, University of Southampton , Southampton SO17 1BJ, United Kingdom
| | - Martyn Hill
- Engineering Sciences, University of Southampton , Southampton SO17 1BJ, United Kingdom
| | - Peter Glynne-Jones
- Engineering Sciences, University of Southampton , Southampton SO17 1BJ, United Kingdom
| |
Collapse
|
8
|
Bryan N, Birch P, Stanley C, Bond D, Hunt JA. The use of acoustic force capture to ultra-purify lymphocyte subpopulations from human adult whole blood. J Tissue Eng Regen Med 2013; 7:812-8. [PMID: 22438176 DOI: 10.1002/term.1474] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2011] [Revised: 07/28/2011] [Accepted: 01/13/2012] [Indexed: 11/11/2022]
Abstract
Pre-analytical enrichment of cell populations prior to therapeutic delivery is of paramount interest throughout the fields of regenerative medicine and clinical interventional therapies. Enrichment of a cell population typically involves two aspects: (a) the increase in concentration of particular subpopulation of the total cell fraction by means of removal of other cells of no interest to the particular interrogation; and (b) improvement of resolution of signal by removal of 'noise' mostly arising from cellular debris in the treated sample. In this research, leukocyte populations were obtained from erythrocyte-depleted primary whole blood from human adults and subjected to flow through acoustic fields within the ultrasound range to remove cellular debris. It was possible to demonstrate aggregation and holding of leukocytes by using ultrasound within the frequency range 11.448-11.483 MHz, which facilitated removal of cellular debris by washing under continuous perfusion. The T-lymphocyte population were phenotypically characterized using CD4/CD8 (T(h)/T(c)) immunocytochemistry by flow cytometry and demonstrated a significant decrease in 'false-positive' events during cellular analysis, due to the efficient eradication of non-specifically reactive cells and tissue debris from the cell populations of interest. Therefore, it was possible to conclude that flow through an ultrasonic acoustic system was capable of providing a non-destructive method for the hyper-purification of primary derived cell populations, with potential exploitations throughout the fields of cellular research, medical diagnostics and clinical therapies.
Collapse
Affiliation(s)
- Nicholas Bryan
- Clinical Engineering, UKCTE, UKBioTEC, University of Liverpool, UK
| | | | | | | | | |
Collapse
|
9
|
Glynne-Jones P, Mishra PP, Boltryk RJ, Hill M. Efficient finite element modeling of radiation forces on elastic particles of arbitrary size and geometry. THE JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA 2013; 133:1885-93. [PMID: 23556558 DOI: 10.1121/1.4794393] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
A finite element based method is presented for calculating the acoustic radiation force on arbitrarily shaped elastic and fluid particles. Importantly for future applications, this development will permit the modeling of acoustic forces on complex structures such as biological cells, and the interactions between them and other bodies. The model is based on a non-viscous approximation, allowing the results from an efficient, numerical, linear scattering model to provide the basis for the second-order forces. Simulation times are of the order of a few seconds for an axi-symmetric structure. The model is verified against a range of existing analytical solutions (typical accuracy better than 0.1%), including those for cylinders, elastic spheres that are of significant size compared to the acoustic wavelength, and spheroidal particles.
Collapse
Affiliation(s)
- Peter Glynne-Jones
- Engineering Sciences, Faculty of Engineering and the Environment, University of Southampton, Southampton, SO17 1BJ, United Kingdom.
| | | | | | | |
Collapse
|
10
|
Hoyos M, Castro A. Controlling the acoustic streaming by pulsed ultrasounds. ULTRASONICS 2013; 53:70-6. [PMID: 22560802 DOI: 10.1016/j.ultras.2012.03.015] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/02/2011] [Revised: 03/29/2012] [Accepted: 03/30/2012] [Indexed: 05/06/2023]
Abstract
We propose a technique based on pulsed ultrasounds for controlling, reducing to a minimum observable value the acoustic streaming in closed ultrasonic standing wave fluidic resonators. By modifying the number of pulses and the repetition time it is possible to reduce the velocity of the acoustic streaming with respect to the velocity generated by the continuous ultrasound mode of operation. The acoustic streaming is observed at the nodal plane where a suspension of 800nm latex particles was focused by primary radiation force. A mixture of 800nm and 15μm latex particles has been also used for showing that the acoustic streaming is hardly reduced while primary and secondary forces continue to operate. The parameter we call "pulse mode factor" i.e. the time of applied ultrasound divided by the duty cycle, is found to be the adequate parameter that controls the acoustic streaming. We demonstrate that pulsed ultrasound is more efficient for controlling the acoustic streaming than the variation of the amplitude of the standing waves.
Collapse
Affiliation(s)
- Mauricio Hoyos
- Laboratoire de Physique et Mécanique des Milieux Hétérogènes, UMR7636 CNRS, Ecole Supérieure de Physique et Chimie Industrielles, ESPCI, 10 rue Vauquelin, 75231 Paris Cedex 05, France.
| | | |
Collapse
|
11
|
Evander M, Nilsson J. Acoustofluidics 20: applications in acoustic trapping. LAB ON A CHIP 2012; 12:4667-76. [PMID: 23047553 DOI: 10.1039/c2lc40999b] [Citation(s) in RCA: 45] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
This part of the Acoustofluidics tutorial series reviews applications in acoustic trapping of micron-sized particles and cells in microfluidic systems. Acoustic trapping enables non-invasive and non-contact immobilisation of cells and particles in microfluidic systems. Acoustic trapping has been used for reducing the time needed to create 3D cell clusters, enhance particle-based bioassays and facilitated interaction studies of both cells and particles. An area that is increasingly interesting is the use of acoustic trapping for enriching low concentration samples and the washing or fractioning of cell populations prior to sensitive detection methods (MALDI-MS, PCR etc.) The main focus of the review is systems where particles can be retained against a flow while applications in which particles are positioned in a stationary fluid will be addressed in part 21 of the Acoustofluidics tutorial series (M. Wiklund, S. Radel and J. J. Hawkes, Lab Chip, 2012, 12, ).
Collapse
Affiliation(s)
- Mikael Evander
- Department of Measurement Technology and Industrial Electrical Engineering, Division of Nanobiotechnology, Lund University, Lund, Sweden.
| | | |
Collapse
|
12
|
Bazou D, Castro A, Hoyos M. Controlled cell aggregation in a pulsed acoustic field. ULTRASONICS 2012; 52:842-850. [PMID: 22534062 DOI: 10.1016/j.ultras.2012.01.005] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/07/2011] [Revised: 01/16/2012] [Accepted: 01/16/2012] [Indexed: 05/31/2023]
Abstract
Cell aggregation in ultrasonic resonators can be obtained in a few seconds. Hundreds even thousands of cells can be levitated in suspension and generate 2D or 3D aggregates. Nevertheless, the aggregation rate and the 2D or 3D configurations of the resultant aggregates are very difficult to control. This work reports on a novel way of generating and controlling particle and cell aggregates using pulsed ultrasound. This technique specifically explores (in addition to the ultrasound wave, frequency and amplitude) the time of ultrasound application, i.e. the number of pulses as well as the pulse repetition frequency. We demonstrate that with pulsed ultrasound, particles and/or cells levitate in suspension, as with continuous ultrasound, and the aggregation rate can be modified in a controlled manner. By carefully tuning the number of pulses and the repetition frequency, the 3-D and 2-D configurations of the aggregates can be selectively generated. In addition, pulsed ultrasound limits transducer heating, thus allowing for higher acoustic energies than those currently employed with continuous ultrasound.
Collapse
Affiliation(s)
- Despina Bazou
- Centre for Research on Adaptive Nanostructures and Nanodevices (CRANN), Trinity College, Dublin, Ireland
| | | | | |
Collapse
|
13
|
Lenshof A, Magnusson C, Laurell T. Acoustofluidics 8: applications of acoustophoresis in continuous flow microsystems. LAB ON A CHIP 2012; 12:1210-23. [PMID: 22362021 DOI: 10.1039/c2lc21256k] [Citation(s) in RCA: 183] [Impact Index Per Article: 15.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
This acoustofluidics tutorial focuses on continuous flow-based half wavelength resonator systems operated in the transversal mode, where the direction of the primary acoustic force acts in plane with the microchip. The transversal actuation mode facilitates integration with up- and downstream microchannel networks as well as visual control of the acoustic focusing experiment. Applications of particle enrichment in an acoustic half wavelength resonator are discussed as well as clarification of the carrier fluid from undesired particles. Binary separation of particle/vesicle/cell mixtures into two subpopulations is outlined based on the different polarities of the acoustic contrast factor. Furthermore, continuous flow separation of different particle/cell types is described where both Free Flow Acoustophoresis (FFA) and binary acoustophoresis are utilized. By capitalizing on the laminar flow regime, acoustophoresis has proven especially successful in performing bead/cell translations between different buffer systems. Likewise, the ability to controllably translate particulate matter across streamlines has opened a route to valving of cells/particles without any moving parts, where event triggered cell sorting is becoming an increasing area of activity. Recent developments now also enable measurements of fundamental cell properties such as density and compressibility by means of acoustophoresis. General aspects on working with live cells in acoustophoresis systems are discussed as well as available means to quantify the outcome of cell and particle separation experiments performed by acoustophoresis.
Collapse
Affiliation(s)
- Andreas Lenshof
- Dept. Measurement Technology and Industrial Electrical Engineering, Div. Nanobiotechnology Lund University, Sweden.
| | | | | |
Collapse
|
14
|
Lenshof A, Evander M, Laurell T, Nilsson J. Acoustofluidics 5: Building microfluidic acoustic resonators. LAB ON A CHIP 2012; 12:684-95. [PMID: 22246532 DOI: 10.1039/c1lc20996e] [Citation(s) in RCA: 118] [Impact Index Per Article: 9.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Acoustophoresis is getting more attention as an effective and gentle non-contact method of manipulating cells and particles in microfluidic systems. A key to a successful assembly of an acoustophoresis system is a proper design of the acoustic resonator where aspects of fabrication techniques, material choice, thickness matching of involved components, as well as strategies of actuation, all have to be considered. This tutorial covers some of the basics in designing and building microfluidic acoustic resonators and will hopefully be a comprehensive and advisory document to assist the interested reader in creating a successful acoustophoretic device.
Collapse
Affiliation(s)
- A Lenshof
- Dept. of Measurement Technology and Industrial Electrical Engineering, Div. of Nanobiotechnology, Lund University, Lund, Sweden
| | | | | | | |
Collapse
|
15
|
Movia D, Prina-Mello A, Bazou D, Volkov Y, Giordani S. Screening the cytotoxicity of single-walled carbon nanotubes using novel 3D tissue-mimetic models. ACS NANO 2011; 5:9278-9290. [PMID: 22017733 DOI: 10.1021/nn203659m] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/31/2023]
Abstract
Single-walled carbon nanotubes (SWNTs) are promising candidates for a wide range of biomedical applications due to their fascinating properties. However, safety concerns are raised on their potential human toxicity and on the techniques that need to be used to assess such toxicity. Here, we integrate for the first time 3D tissue-mimetic models in the cytotoxicity assessment of purified (p-) and oxidized (o-) SWNTs. An established ultrasound standing wave trap was used to generate the 3D cell aggregates, and results were compared with traditional 2D cell culture models. Protein-based (bovine serum albumin) and surfactant-based (Pluronic F68) nanotube dispersions were tested and compared to a reference suspension in dimethyl sulfoxide. Our results indicated that p- and o-SWNTs were not toxic in the 3D cellular model following a 24 h exposure. In contrast, 2D cell cultures were significantly affected by exposure to p- and o-SWNTs after 24 h, as assessed by high-content screening and analysis (HCSA). Finally, cytokine (IL-6 and TNF-α) secretion levels were elevated in the 2D but remained essentially unchanged in the 3D cell models. Our results strongly indicate that 3D cell aggregates can be used as alternative in vitro models providing guidance on nanomaterial toxicity in a tissue-mimetic manner, thus offering future cost-effective solutions for toxicity screening assays under the experimental conditions more closely related to the physiological scenario in 3D tissue microenvironments.
Collapse
Affiliation(s)
- Dania Movia
- Centre for Research on Adaptive Nanostructures and Nanodevices (CRANN), Trinity College Dublin, Ireland
| | | | | | | | | |
Collapse
|
16
|
Choudhury D, Mo X, Iliescu C, Tan LL, Tong WH, Yu H. Exploitation of physical and chemical constraints for three-dimensional microtissue construction in microfluidics. BIOMICROFLUIDICS 2011; 5:22203. [PMID: 21799710 PMCID: PMC3145229 DOI: 10.1063/1.3593407] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/13/2011] [Accepted: 05/02/2011] [Indexed: 05/06/2023]
Abstract
There are a plethora of approaches to construct microtissues as building blocks for the repair and regeneration of larger and complex tissues. Here we focus on various physical and chemical trapping methods for engineering three-dimensional microtissue constructs in microfluidic systems that recapitulate the in vivo tissue microstructures and functions. Advances in these in vitro tissue models have enabled various applications, including drug screening, disease or injury models, and cell-based biosensors. The future would see strides toward the mesoscale control of even finer tissue microstructures and the scaling of various designs for high throughput applications. These tools and knowledge will establish the foundation for precision engineering of complex tissues of the internal organs for biomedical applications.
Collapse
|
17
|
Bazou D, Kearney R, Mansergh F, Bourdon C, Farrar J, Wride M. Gene expression analysis of mouse embryonic stem cells following levitation in an ultrasound standing wave trap. ULTRASOUND IN MEDICINE & BIOLOGY 2011; 37:321-30. [PMID: 21208732 PMCID: PMC3032046 DOI: 10.1016/j.ultrasmedbio.2010.10.019] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/08/2010] [Revised: 09/01/2010] [Accepted: 10/15/2010] [Indexed: 05/04/2023]
Abstract
In the present paper, gene expression analysis of mouse embryonic stem (ES) cells levitated in a novel ultrasound standing wave trap (USWT) (Bazou et al. 2005a) at variable acoustic pressures (0.08-0.85 MPa) and times (5-60 min) was performed. Our results showed that levitation of ES cells at the highest employed acoustic pressure for 60 min does not modify gene expression and cells maintain their pluripotency. Embryoid bodies (EBs) also expressed the early and late neural differentiation markers, which were also unaffected by the acoustic field. Our results suggest that the ultrasound trap microenvironment is minimally invasive as the biologic consequences of ES cell replication and EB differentiation proceed without significantly affecting gene expression. The technique holds great promise in safe cell manipulation techniques for a variety of applications including tissue engineering and regenerative medicine.
Collapse
Affiliation(s)
- Despina Bazou
- Centre for Research on Adaptive Nanostructures and Nanodevices (CRANN), Trinity College Dublin, Dublin, Ireland.
| | | | | | | | | | | |
Collapse
|
18
|
Mazzoccoli JP, Feke DL, Baskaran H, Pintauro PN. Development of multilayered cell-hydrogel composites using an acoustic focusing technique. Biotechnol Prog 2010; 26:600-5. [PMID: 19938043 DOI: 10.1002/btpr.332] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Multilayered composites, composed of mammalian cells arranged in a hydrogel, have been prepared using an acoustic focusing technique. Acoustic focusing is a simple, nonchemical technique that allows for the fast arrangement of cells in matrices where the control of cell geometry is beneficial. Breast cancer cells (MDA-MB231) were dispersed in a 30 wt % solution of poly(ethylene glycol) diacrylate (PEGDA) of molecular weight 400 at a density of 5 x 10(6) cells/mL of PEGDA solution. An ultrasonic field was used to organize the cells before polymerization of PEGDA. Disk-shaped hydrogel composites, typically 1 cm in diameter and 2-mm thick were prepared based on a PEGDA solution volume of 130 microL. At an acoustic frequency of 2.32 MHz, composites having cells positioned within concentric cylindrical shells interspersed with zones of cell-free hydrogel were produced. The cells were located in annuli approximately 80-microm thick and about 300 microm apart. The structure and viability of the cells within these constructs were studied using a fluorescent LIVE/DEAD assay. The viability of the cells was on the order of 50%. For the conditions used in this study, cell death was primarily attributed to exposure of cells to the PEGDA solution prior to polymerization, rather than adverse effects of polymerization or the sound field itself.
Collapse
Affiliation(s)
- Jason P Mazzoccoli
- Dept. of Chemical Engineering, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, OH 44106, USA
| | | | | | | |
Collapse
|
19
|
Kuznetsova LA, Bazou D, Edwards GO, Coakley WT. Multiple three-dimensional mammalian cell aggregates formed away from solid substrata in ultrasound standing waves. Biotechnol Prog 2009; 25:834-41. [PMID: 19399828 DOI: 10.1002/btpr.164] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Single and multiple three-dimensional cell aggregates of human red blood cells (RBCs) and HepG2 cells were formed rapidly in low mega-Hertz ultrasound standing wave fields of different geometries. A single discoid aggregate was formed in a half-wavelength pathlength resonator at a cell concentration sufficient to produce a 3D structure. Multiple cell aggregates were formed on the axis of a cylindrical resonator with a plane transducer (discoid aggregates); in a resonator with a tubular transducer and in the cross-fields of plane and tubular transducers and two plane orthogonal transducers (all cylindrical aggregates). Mechanically strong RBC aggregates were obtained by crosslinking with wheat germ agglutinin (WGA, a lectin). Scanning electron microscopy showed aggregate surface porous structures when RBCs were mixed with WGA before sonication and tighter packing when ultrasonically preformed aggregates were subsequently exposed to a flow containing WGA. HepG2 cell aggregates showed strong accumulation of F-actin at sites of cell-cell contact consistent with increased mechanical stability. The aggregates had a porous surface, and yet confocal microscopy revealed a tight packing of cells in the aggregate's inner core.
Collapse
|
20
|
Bazou D, Davies G, Jiang WG, Coakley T. Rapid Molecular and Morphological Responses of Prostate Cell Lines to Cell–Cell Contact. ACTA ACUST UNITED AC 2009; 13:279-94. [PMID: 17162670 DOI: 10.1080/15419060601077909] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Cell-cell adhesion in 2-D PZ-HPV-7 prostate epithelial and DU-145 prostate cancer cell aggregates (monolayers), synchronously and rapidly (within 30 s) formed in suspension in an ultrasound trap has been examined over 60 min. The intracellular distributions of the cadherin/catenin complex components for both cell lines were time-dependent and were clearly identifiable as early as 150 s following cell-cell contact in the trap, while equilibrium positions were reached within 60 min following cell-cell contact. The accumulation of E-cadherin at the cell-cell interface was greater for PZ-HPV-7 than for DU-145 cells over 60 min in the trap, with the apparent formation of adherens junctions over that time scale in PZ-HPV-7 but not in DU-145 cells. The amounts of F-actin, alpha-, beta-, and gamma-catenins recruited to the cell-cell interface of PZ-HPV-7 cells were on average 2.4 times higher than those of DU-145 cells. The ability of different cell types to spread along neighboring cells was 1.5-fold greater for the PZ-HPV-7 than for the DU-145 cells. These results, discussed also in the context of earlier studies of cell adhesion in an ultrasound trap, characterize a reduced adhesiveness of DU-145 cells compared to PZ-HPV-7 cells.
Collapse
Affiliation(s)
- Despina Bazou
- Cardiff School of Biosciences, Cardiff University, Cardiff, UK
| | | | | | | |
Collapse
|
21
|
Edwards GO, Bazou D, Kuznetsova LA, Coakley WT. Cell Adhesion Dynamics and Actin Cytoskeleton Reorganization in HepG2 Cell Aggregates. ACTA ACUST UNITED AC 2009; 14:9-20. [PMID: 17453827 DOI: 10.1080/15419060701224849] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Abstract
The temporal dependence of cytoskeletal remodelling on cell-cell contact in HepG2 cells has been established here. Cell-cell contact occurred in an ultrasound standing wave trap designed to form and levitate a 2-D cell aggregate, allowing intercellular adhesive interactions to proceed, free from the influences of solid substrata. Membrane spreading at the point of contact and change in cell circularity reached 50% of their final values within 2.2 min of contact. Junctional F-actin increased at the interface but lagged behind membrane spreading, reaching 50% of its final value in 4.4 min. Aggregates had good mechanical stability after 15 min in the trap. The implication of this temporal dependence on the sequential progress of adhesion processes is discussed. These results provide insight into how biomimetic cell aggregates with some liver cell functions might be assembled in a systematic, controlled manner in a 3-D ultrasound trap.
Collapse
Affiliation(s)
- Gareth Owain Edwards
- Cardiff School of Biosciences, Main Building, Cardiff University, Cardiff, Wales, UK.
| | | | | | | |
Collapse
|
22
|
Bazou D, Blain EJ, Terence Coakley W, Bazou D, Blain EJ, Terence Coakley W. NCAM and PSA-NCAM dependent membrane spreading and F-actin reorganization in suspended adhering neural cells. Mol Membr Biol 2009; 25:102-14. [DOI: 10.1080/09687680701618365] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Despina Bazou
- School of Biosciences, Cardiff University, Cardiff, Wales, UK
| | - Emma J. Blain
- School of Biosciences, Cardiff University, Cardiff, Wales, UK
| | | | - Despina Bazou
- School of Biosciences, Cardiff University, Cardiff, Wales, UK
| | - Emma J. Blain
- School of Biosciences, Cardiff University, Cardiff, Wales, UK
| | | |
Collapse
|
23
|
Bazou D, Foster GA, Ralphs JR, Coakley WT. Molecular adhesion development in a neural cell monolayer forming in an ultrasound trap. Mol Membr Biol 2009; 22:229-40. [PMID: 16096265 DOI: 10.1080/09687860500093396] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
A 2-dimensional aggregate of C6 neural cells was formed rapidly (within 30 s) in suspension in a recently developed 1.5 MHz ultrasound standing wave trap. A typical 1 mm diameter aggregate contained about 3,500 cells. Spreading of membrane occurred between the aggregated cells. The rate of spreading of the tangentially developing intercellular contact area was 0.19 microm/min. The form of the suspended aggregate changed from one of a hexagonal arrangement of cells to one of a cell-monolayer-like continuous sheet of mostly quadrilateral and pentagonal cells as in a cell monolayer on a solid substratum. A range of fluorescent indicators showed that the >99% viability of the cells did not change during 1 h exposures; therefore cell viability was not compromised during the monolayer development. The average integral intensities from stained actin filaments at the spreading cell-cell interfaces after 1, 8 and 30 min were 14, 25 and 46 microm(2) respectively. The cells in this work progressed from physical aggregation, through molecular adhesion, to displaying the intracellular consequences of receptor interactions. The ability to form mechanically strong confluent monolayer structures that can be monitored in situ or harvested from the trap provides a technique with general potential for monitoring the synchronous development of cell responses to receptor-triggered adhesion.
Collapse
Affiliation(s)
- Despina Bazou
- Cardiff School of Biosciences, Cardiff University, Cardiff CF10 3TL, Wales, UK
| | | | | | | |
Collapse
|
24
|
Bazou D. Biochemical properties of encapsulated high-density 3-D HepG2 aggregates formed in an ultrasound trap for application in hepatotoxicity studies. Cell Biol Toxicol 2009; 26:127-41. [DOI: 10.1007/s10565-009-9123-0] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2008] [Accepted: 03/11/2009] [Indexed: 12/24/2022]
|
25
|
Bazou D, Coakley W, Hayes A, Jackson S. Long-term viability and proliferation of alginate-encapsulated 3-D HepG2 aggregates formed in an ultrasound trap. Toxicol In Vitro 2008; 22:1321-31. [DOI: 10.1016/j.tiv.2008.03.014] [Citation(s) in RCA: 64] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/23/2007] [Revised: 03/28/2008] [Accepted: 03/29/2008] [Indexed: 11/27/2022]
|
26
|
Kuznetsova LA, Bazou D, Coakley WT. Stability of 2-D colloidal particle aggregates held against flow stress in an ultrasound trap. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2007; 23:3009-16. [PMID: 17286416 DOI: 10.1021/la062164k] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
The formation of a two-dimensional aggregate of 25 microm latex particles in a 1.5 MHz ultrasound standing wave (USW) field and its disintegration in a flow were studied. The aggregate was held in the pressure node plane, which allowed continuous microscope observation and video recording of the processes. The trajectories and velocities of the particles approaching the formation site were analyzed by particle image velocimetry (PIV). Since the direct radiation force on the particles dominated the drag due to acoustic streaming, the acoustic pressure profile in the vicinity of the aggregate was quantifiable. The drag coefficients D(coef) for 2- to 485-particle aggregates were estimated from the balance of the drag force FD and the buoyancy-corrected gravitational force during sedimentation on termination of the ultrasound when the long axis of the aggregate was in the vertical plane. D(coef) were calculated from FD as proportional to the aggregate velocity. Experiments on particle detachment by flow (in-plane velocity measured by PIV) from horizontal aggregates suspended in deionized water and CaCl2 solution of different concentrations showed that the mechanical strength of the aggregates depended on the acoustic pressure amplitude P0 and ionic strength of the solution. In deionized water the flow velocity required to detach the first single particle from an aggregate increased from 1 mm s-1 at P0 = 0.6 MPa to 4.2 mm s-1 at P0 = 1.4 MPa. The balance of forces acting on particles in a USW trap is discussed. The magnitude of the shear stress employed ( approximately 0.05 Pa) and separation forces suggests that this technique can be applied to studying the mechanical responses of cell aggregates to hydrodynamic flow, where cell-cell interaction can be separated from the effects of solid substrata.
Collapse
Affiliation(s)
- Larisa A Kuznetsova
- School of Biosciences, Cardiff University, Park Place, Cardiff CF10 3TL, United Kingdom.
| | | | | |
Collapse
|
27
|
Bazou D, Dowthwaite GP, Khan IM, Archer CW, Ralphs JR, Coakley WT. Gap junctional intercellular communication and cytoskeletal organization in chondrocytes in suspension in an ultrasound trap. Mol Membr Biol 2006; 23:195-205. [PMID: 16754362 DOI: 10.1080/09687860600555906] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
Abstract
Particles or cells suspended in an appropriately designed ultrasound standing wave field can be aggregated at a node to form a single monolayer in a plane that can be interrogated microscopically. The approach is applied here to investigate the temporal development of F-actin and Cx43 distribution and of gap junctional intercellular communication in 2-D chondrocyte aggregates (monolayers) rapidly and synchronously formed and held in suspension in an ultrasound trap. Development of the F-actin cytoskeleton in the confluent single layer of 'cuboidal' cells forming the aggregate was completed within 1 h. Chondrocytes levitated in the trap synchronously formed functional gap junctions (as assessed by CMFDA dye transfer assays) in less than 1 h of initiation of cell-cell contact in the trap. It was shown that Cx43 gene expression was retained in isolated chondrocytes in suspension. Preincubation of cells with the protein synthesis inhibitor cycloheximide caused a six-fold decrease in Cx43 accumulation (as assessed by immunofluorescence) at the interfaces of chondrocytes in the aggregate. It is shown that the ultrasound trap provides an approach to studying the early stages of cytoskeletal and gap junction development as cells progress from physical aggregation, through molecular adhesion, to display the intracellular consequences of receptor interactions.
Collapse
Affiliation(s)
- Despina Bazou
- Cardiff University, School of Biosciences, Cardiff, Wales, UK
| | | | | | | | | | | |
Collapse
|
28
|
Bazou D, Kuznetsova LA, Coakley WT. Physical enviroment of 2-D animal cell aggregates formed in a short pathlength ultrasound standing wave trap. ULTRASOUND IN MEDICINE & BIOLOGY 2005; 31:423-30. [PMID: 15749566 DOI: 10.1016/j.ultrasmedbio.2004.12.007] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/16/2004] [Revised: 11/23/2004] [Accepted: 12/02/2004] [Indexed: 05/10/2023]
Abstract
2-D mammalian cell aggregates can be formed and levitated in a 1.5 MHz single half wavelength ultrasound standing wave trap. The physical environment of cells in such a trap has been examined. Attention was paid to parameters such as temperature, acoustic streaming, cavitation and intercellular forces. The extent to which these factors might be intrusive to a neural cell aggregate levitated in the trap was evaluated. Neural cells were exposed to ultrasound at a pressure amplitude of 0.54 MPa for 30 s; a small aggregate had been formed at the center of the trap. The pressure amplitude was then decreased to 0.27 MPa for 2 min, at which level the aggregation process continued at a slower rate. The pressure amplitude was then decreased to 0.06 MPa for 1 h. Temperature measurements that were conducted in situ with a 200 microm thermocouple over a 30 min period showed that the maximum temperature rise was less than 0.5 K. Acoustic streaming was measured by the particle image velocimetry method (PIV). It was shown that the hydrodynamic stress imposed on cells by acoustic streaming is less than that imposed by gentle preparative centrifugation procedures. Acoustic spectrum analysis showed that cavitation activity does not occur in the cell suspensions sonicated at the above pressures. White noise was detected only at a pressure amplitude of 1.96 MPa. Finally, it was shown that the attractive acoustic force between ultrasonically agglomerated cells is small compared with the normal attractive van der Waals force that operates at close cell surface separations. It is concluded that the standing wave trap operates only to concentrate cells locally, as in tissue, and does not modify the in vitro expression of surface receptor interactions.
Collapse
Affiliation(s)
- Despina Bazou
- Cardiff School of Biosciences, Cardiff University, Cardiff, United Kingdom
| | | | | |
Collapse
|