1
|
Tang L, Li D, Liu W, Tang Y, Zhang R, Tian Y, Tan R, Yang X, Sun L. Microneedle electrochemical sensor based on disposable stainless-steel wire for real-time analysis of indole-3-acetic acid and salicylic acid in tomato leaves infected by Pst DC3000 in situ. Anal Chim Acta 2024; 1316:342875. [PMID: 38969433 DOI: 10.1016/j.aca.2024.342875] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2024] [Revised: 06/07/2024] [Accepted: 06/13/2024] [Indexed: 07/07/2024]
Abstract
BACKGROUND Indole-3-acetic acid (IAA) and salicylic acid (SA), pivotal regulators in plant growth, are integral to a variety of plant physiological activities. The ongoing and simultaneous monitoring of these hormones in vivo enhances our comprehension of their interactive and regulatory roles. Traditional detection methods, such as liquid chromatography-mass spectrometry, cannot obtain precise and immediate information on IAA and SA due to the complexity of sample processing. In contrast, the electrochemical detection method offers high sensitivity, rapid response times, and compactness, making it well-suited for in vivo or real-time detection applications. RESULTS A microneedle electrochemical sensor system crafted from disposable stainless steel (SS) wire was specifically designed for the real-time assessment of IAA and SA in plant in situ. This sensor system included a SS wire (100 μm diameter) coated with carbon cement and multi-walled carbon nanotubes, a plain platinum wire (100 μm diameter), and an Ag/AgCl wire (100 μm diameter). Differential pulse voltammetry and amperometry were adopted for detecting SA and IAA within the range of 0.1-20 μM, respectively. This sensor was applied to track IAA and SA fluctuations in tomato leaves during PstDC3000 infection, offering continuous data. Observations indicated an uptick in SA levels following infection, while IAA production was suppressed. The newly developed disposable SS wire-based microneedle electrochemical sensor system is economical, suitable for mass production, and inflicts minimal damage during the monitoring of SA and IAA in plant tissues. SIGNIFICANCE This disposable microneedle electrochemical sensor facilitates in vivo detection of IAA and SA in smaller plant tissues and allows for long-time monitoring of their concentrations, which not only propels research into the regulatory and interaction mechanisms of IAA and SA but also furnishes essential tools for advancing precision agriculture.
Collapse
Affiliation(s)
- Lingjuan Tang
- School of Life Sciences, Nantong University, 9 Seyuan Road, Nantong, Jiangsu, 226019, China; Analysis and Testing Center, Nantong University, 9 Seyuan Road, Nantong, Jiangsu, 226019, China
| | - Daodong Li
- School of Life Sciences, Nantong University, 9 Seyuan Road, Nantong, Jiangsu, 226019, China
| | - Wei Liu
- School of Life Sciences, Nantong University, 9 Seyuan Road, Nantong, Jiangsu, 226019, China
| | - Yihui Tang
- School of Life Sciences, Nantong University, 9 Seyuan Road, Nantong, Jiangsu, 226019, China
| | - Rongcheng Zhang
- School of Life Sciences, Nantong University, 9 Seyuan Road, Nantong, Jiangsu, 226019, China
| | - Yiran Tian
- School of Life Sciences, Nantong University, 9 Seyuan Road, Nantong, Jiangsu, 226019, China
| | - Rong Tan
- School of Life Sciences, Nantong University, 9 Seyuan Road, Nantong, Jiangsu, 226019, China
| | - Xiaolong Yang
- School of Life Sciences, Nantong University, 9 Seyuan Road, Nantong, Jiangsu, 226019, China.
| | - Lijun Sun
- School of Life Sciences, Nantong University, 9 Seyuan Road, Nantong, Jiangsu, 226019, China.
| |
Collapse
|
2
|
Sotoudeh Bagha P, Paternoster C, Khakbiz M, Sheibani S, Gholami N, Mantovani D. Surface Modification of an Absorbable Bimodal Fe-Mn-Ag Alloy by Nitrogen Plasma Immersion Ion Implantation. MATERIALS (BASEL, SWITZERLAND) 2023; 16:1048. [PMID: 36770055 PMCID: PMC9919902 DOI: 10.3390/ma16031048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 01/11/2023] [Accepted: 01/16/2023] [Indexed: 06/18/2023]
Abstract
Recently, Fe-Mn-based alloys have been increasingly catching the attention of the scientific community, because of their tunable and outstanding mechanical properties, and suitable degradation behavior for biomedical applications. In spite of these assets, their corrosion rate (CR) is, in general, too low to satisfy the requirements that need to be met for cardiovascular device applications, such as stents. In fact, the CR is not always the same for all of the degradation stages of the material, and in addition, a finely tuned release rate, especially during the first steps of the corrosion pattern, is often demanded. In this work, a resorbable bimodal multi-phase alloy Fe-3Mn-1Ag was designed by mechanical alloying and spark plasma sintering (SPS) to accelerate the corrosion rate. The presence of several phases, for example α-Fe, α-Mn, γ-FeMn and Ag, provided the material with excellent mechanical properties (tensile strength UTS = 722 MPa, tensile strain A = 38%) and a higher corrosion rate (CR = 3.2 ± 0.2 mm/year). However, higher corrosion rates, associated with an increased release of degradation elements, could also raise toxicity concerns, especially at the beginning of the corrosion pattern. In this study, The focus of the present work was the control of the CR by surface modification, with nitrogen plasma immersion ion implantation (N-PIII) treatment that was applied to mechanically polished (MP) samples. This plasma treatment (PT) improved the corrosion resistance of the material, assessed by static degradation immersion tests (SDITs), especially during the first degradation stages. Twenty-eight days later, the degradation rate reached the same value of the MP condition. Nitrogen compounds on the surface of the substrate played an important role in the corrosion mechanism and corrosion product formation. The degradation analysis was carried out also by potentiodynamic tests in modified Hanks' balanced salt solution (MHBSS), and Dulbecco's phosphate buffered saline solution (DPBSS). The corrosion rate was higher in MHBSS for both conditions. However, there was no significant difference between the corrosion rate of the PT in DPBSS (CR = 1.9 ± 0.6 mm/year) and in MHBSS (CR = 2 ± 1.4 mm/year). The cell viability was assessed with human vein endothelial cells (HUVECs) via an indirect metabolic activity test (MTT assay). Due to the lower ion release of the PT condition, the cell viability increased significantly. Thus, nitrogen implantation can control the in vitro corrosion rate starting from the very first stage of the implantation, improving cell viability.
Collapse
Affiliation(s)
- Pedram Sotoudeh Bagha
- BiionixTM (Bionic Materials, Implants & Interfaces) Cluster, Department of Medicine, University of Central Florida College of Medicine, Orlando, FL 32827, USA
| | - Carlo Paternoster
- Lab Biomaterials and Bioengineering, CRC-I, Department of Mining, Metallurgical and Materials Engineering & CHU de Quebec Research Center, Regenerative Medicine, Laval University, Quebec City, QC G1V 0A6, Canada
| | - Mehrdad Khakbiz
- Department of Chemical and Biochemical Engineering, Rutgers, The State University of New Jersey, Piscataway, NJ 088854, USA
- Division of Biomedical Engineering, Faculty of New Sciences and Technologies, University of Tehran, Tehran 14395-1561, Iran
| | - Saeed Sheibani
- School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, Tehran 11155-4563, Iran
| | - Navid Gholami
- Department of Tissue Engineering and Applied Cell Sciences, School of Advanced Technologies in Medicine, Tehran University of Medical Sciences, Tehran 14177-55469, Iran
| | - Diego Mantovani
- Lab Biomaterials and Bioengineering, CRC-I, Department of Mining, Metallurgical and Materials Engineering & CHU de Quebec Research Center, Regenerative Medicine, Laval University, Quebec City, QC G1V 0A6, Canada
| |
Collapse
|
3
|
Sun L, Xu S, Tang Y, Zhou Y, Wang M, Tian Y, Li G, Zhu X, Bao N, Sun L. Disposable stainless steel working electrodes for sensitive and simultaneous detection of indole-3-acetic acid and salicylic acid in Arabidopsis thaliana leaves under biotic stresses. Anal Bioanal Chem 2022; 414:7721-7730. [PMID: 36068347 DOI: 10.1007/s00216-022-04303-0] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2022] [Revised: 08/21/2022] [Accepted: 08/23/2022] [Indexed: 11/30/2022]
Abstract
The detection of phytohormones in real time has attracted increasing attention because of their critical roles in regulating the development and signaling of plants, especially in defense against biotic stresses. Herein, stainless steel sheet electrodes modified with carbon cement were coupled with paper-based analysis devices for direct and simultaneous detection of salicylic acid (SA) and indole-3-acetic acid (IAA) in plants. We demonstrated that the excellent conductivity of stainless steel sheet electrodes enabled us to simultaneously differentiate IAA and SA at a level of 10 nM. With our approach, the content of IAA and SA in Arabidopsis thaliana leaves infected or not infected with Pst DC3000 could be rapidly quantified at the same time. Our experimental results on differentiation of IAA and SA at different time points showed that there were antagonistic interactions between the IAA and SA after infection of Arabidopsis leaves with Pst DC3000. By offering a cost-effective approach for rapid and sensitive detection of IAA and SA, this study suggests that electrochemical detection can be used in the study and development of precision agriculture technology.
Collapse
Affiliation(s)
- Ling Sun
- School of Life Sciences, Nantong University, 9 Seyuan Rd, Nantong, 226019, Jiangsu, China
| | - Songzhi Xu
- School of Life Sciences, Nantong University, 9 Seyuan Rd, Nantong, 226019, Jiangsu, China
| | - Yihui Tang
- School of Life Sciences, Nantong University, 9 Seyuan Rd, Nantong, 226019, Jiangsu, China
| | - Yuhang Zhou
- School of Life Sciences, Nantong University, 9 Seyuan Rd, Nantong, 226019, Jiangsu, China
| | - Meng Wang
- School of Life Sciences, Nantong University, 9 Seyuan Rd, Nantong, 226019, Jiangsu, China
| | - Yiran Tian
- School of Life Sciences, Nantong University, 9 Seyuan Rd, Nantong, 226019, Jiangsu, China
| | - Guangxi Li
- School of Life Sciences, Nantong University, 9 Seyuan Rd, Nantong, 226019, Jiangsu, China
| | - Xinyu Zhu
- School of Life Sciences, Nantong University, 9 Seyuan Rd, Nantong, 226019, Jiangsu, China.
| | - Ning Bao
- School of Public Health, Nantong University, 9 Seyuan Rd, Nantong, 226019, Jiangsu, China.
| | - Lijun Sun
- School of Life Sciences, Nantong University, 9 Seyuan Rd, Nantong, 226019, Jiangsu, China.
| |
Collapse
|
4
|
Ryu G, Park K, Kim H. Interfacial properties of liquid metal immersed in various liquids. J Colloid Interface Sci 2022; 621:285-294. [DOI: 10.1016/j.jcis.2022.04.037] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 03/29/2022] [Accepted: 04/06/2022] [Indexed: 11/15/2022]
|
5
|
Fischer D, Cheng KY, Neto MQ, Hall D, Bijukumar D, Orías AAE, Pourzal R, van Arkel RJ, Mathew MT. Corrosion Behavior of Selective Laser Melting (SLM) Manufactured Ti6Al4V Alloy in Saline and BCS Solution. JOURNAL OF BIO- AND TRIBO-CORROSION 2022; 8:63. [PMID: 37736215 PMCID: PMC10512820 DOI: 10.1007/s40735-022-00657-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 02/16/2022] [Accepted: 03/08/2022] [Indexed: 09/23/2023]
Abstract
The frequency of surgeries involving the use of metal implants in orthopedic medicine to replace degenerative or fractured joints is increasing, and it is therefore important to optimize the lifespan and quality of these implants. Advances in additive manufacturing (AM), or 3D printing, are creating new opportunities to personalize implants in ways that reduce mechanical stress at the joint implant interface and improve bone ingrowth and implant stability; however, it is not well understood if and to what degree the AM process alters the corrosion behavior of the materials it produces. In this study, six Ti6Al4V prints manufactured via a selective laser melting (SLM) method were examined regarding their corrosion behavior in both saline and bovine calf serum (BCS) solutions. Ecorr and Icorr values were comparable between the CM-Ti6Al4V control and SLM-EDM surfaces; however, SLM surfaces were found to have more narrow passivation behavior evidenced by significant decreases in Epass values relative to CM-Ti6Al4V. We believe this is a consequence of microstructural differences between CM-Ti6Al4V and SLM-Ti6Al4V. Specifically, the SLM-Ti6Al4V demonstrated a dominant α' martensitic microstructure and decreased vanadium-rich β-phase. BCS solution had a detrimental effect on potential parameters, Ecorr and OCP, decreasing these values relative to their saline counterparts. Increased surface roughness of the SLM-printed surface seemed to amplify the effects of the BCS solution. Furthermore, modest decreases in Epass and Ipass were observed in BCS solution, suggesting that the presence of protein may also interfere with passivation behavior. These findings have implications for how SLM-Ti6Al4V implants will perform in vivo and could possibly influence implant longevity and performance.
Collapse
Affiliation(s)
- David Fischer
- Department of Biomedical Science, University of Illinois College of Medicine Rockford, Rockford, IL, USA
| | - Kai-yuan Cheng
- Department of Biomedical Science, University of Illinois College of Medicine Rockford, Rockford, IL, USA
| | - Mozart Queiroz Neto
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Deborah Hall
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | - Divya Bijukumar
- Department of Biomedical Science, University of Illinois College of Medicine Rockford, Rockford, IL, USA
| | | | - Robin Pourzal
- Department of Orthopedic Surgery, Rush University Medical Center, Chicago, IL, USA
| | | | - Mathew T. Mathew
- Department of Biomedical Science, University of Illinois College of Medicine Rockford, Rockford, IL, USA
| |
Collapse
|
6
|
Chen C, Wang Y, Zhang D, Zhang Z. 316 stainless steel wire mesh for visual detection of H 2O 2, glutathione and glucose based on the peroxidase-like activity. ANAL SCI 2022; 38:941-948. [PMID: 35482234 DOI: 10.1007/s44211-022-00115-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2022] [Accepted: 04/03/2022] [Indexed: 11/30/2022]
Abstract
Stainless steel is a frequently used and cost-effective material. In this study, we discovered for the first time that fresh 316ss possessed an intrinsic peroxidase (POD) catalytic activity, which can catalyze the substrate of POD-like reaction 3,3',5,5'-tetramethylbenzidine (TMB) changing to a blue-colored product, oxidation of TMB, in the presence of hydrogen peroxide (H2O2). Subsequently, a rapid method was conducted to enable the active composites of the 316ss with reused POD activity for 25 circles at least. Based on this finding, the method exhibits a highly sensitive and selective application for H2O2, glutathione (GSH), and Glucose determination. The linear range of glucose detection was 5-100 μM and the detection limit was 3 μM. Finally, this method was further used for detection of glucose in human serum. This work finds a new function of 316ss and develops its novel application, which promotes the potential application of nanozyme in nanoscience and nanotechnology. Schematic representation of the enzyme mimic activities of 316ss wire mesh for the colorimetric detection of hydrogen peroxide H2O2 and GSH with a superior reusability for more than 25 cycles. Based on this, the colorimetric detection of glucose can be constructed combined with GOx.
Collapse
Affiliation(s)
- Chao Chen
- CAS Key Laboratory of Marine Environmental Corrosion and Bio-Fouling, Institute of Oceanology, Chinese Academy of Sciences, 7 Nanhai Road, Qingdao, 266071, China.,Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), 1 Wenhai Road, Qingdao, 266237, China
| | - Yi Wang
- CAS Key Laboratory of Marine Environmental Corrosion and Bio-Fouling, Institute of Oceanology, Chinese Academy of Sciences, 7 Nanhai Road, Qingdao, 266071, China. .,Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), 1 Wenhai Road, Qingdao, 266237, China.
| | - Dun Zhang
- CAS Key Laboratory of Marine Environmental Corrosion and Bio-Fouling, Institute of Oceanology, Chinese Academy of Sciences, 7 Nanhai Road, Qingdao, 266071, China. .,Open Studio for Marine Corrosion and Protection, Pilot National Laboratory for Marine Science and Technology (Qingdao), 1 Wenhai Road, Qingdao, 266237, China.
| | - Zhihao Zhang
- CAS Key Laboratory of Marine Environmental Corrosion and Bio-Fouling, Institute of Oceanology, Chinese Academy of Sciences, 7 Nanhai Road, Qingdao, 266071, China
| |
Collapse
|
7
|
Pujol Pozo AA, Monroy-Guzmán F, Gómora- Herrera DR, Navarrete-Bolaños J, Bustos Bustos E. Radioactive decontamination of metal surfaces using peelable films made from chitosan gels and chitosan/magnetite nanoparticle composites. PROGRESS IN NUCLEAR ENERGY 2022. [DOI: 10.1016/j.pnucene.2021.104088] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/04/2023]
|
8
|
Moon CH, Yasmeen S, Park K, Gaiji H, Chung C, Kim H, Moon HS, Choi JW, Lee HBR. Icephobic Coating through a Self-Formed Superhydrophobic Surface Using a Polymer and Microsized Particles. ACS APPLIED MATERIALS & INTERFACES 2022; 14:3334-3343. [PMID: 34981919 DOI: 10.1021/acsami.1c22404] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Icephobic coatings have been extensively studied for decades to overcome the potential damage associated with ice formation in various devices that are operated under harsh weather conditions. Superhydrophobic surface coatings have been applied for icephobic coating applications owing to their low surface energy. In this study, an icephobic coating of a self-formed superhydrophobic surface using polydimethylsiloxane (PDMS) and SiO2 powder was investigated. The effect of superhydrophobicity on icephobicity was determined by varying the experimental parameters. Polyvinylidene fluoride (PVDF) was added to the PDMS solution to improve the mechanical properties of the icephobic layer. The PDMS-PVDF solution also showed a self-formation behavior into a superhydrophobic surface. In addition, the icephobicity and mechanical properties of the PDMS-PVDF mixture coating improved because of the multilevel nanostructure formed by physical and chemical interactions between the mixture and SiO2 powder. We believe that the proposed approach will be a suitable candidate for various practical applications of icephobicity and a model system to understand the correlation between superhydrophobicity and icephobicity.
Collapse
Affiliation(s)
- Chan Hui Moon
- Department of Materials Science & Engineering, Incheon National University, Incheon 22012, South Korea
| | - Sumaira Yasmeen
- Department of Materials Science & Engineering, Incheon National University, Incheon 22012, South Korea
| | - Kiho Park
- School of Chemical and Biological Engineering, Seoul National University, Seoul 08826, South Korea
| | - Houda Gaiji
- Department of Materials Science & Engineering, Incheon National University, Incheon 22012, South Korea
| | - Changhyun Chung
- Office of Technology Development & Service, Korea Polar Research Institute, Incheon 21990, South Korea
| | - Hyoungkwon Kim
- Office of Technology Development & Service, Korea Polar Research Institute, Incheon 21990, South Korea
| | - Hyoung-Seok Moon
- Energy Plant R&D Group, Korea Institute of Industrial Technology, Busan 31056, South Korea
| | - Jang Wook Choi
- School of Chemical and Biological Engineering, Seoul National University, Seoul 08826, South Korea
| | - Han-Bo-Ram Lee
- Department of Materials Science & Engineering, Incheon National University, Incheon 22012, South Korea
| |
Collapse
|
9
|
Talha M, Ma Y, Lin Y, Mandal AK, Sinha OP, Kong X. Corrosion performance of various deformed surfaces of implant steel for coronary stent applications: Effect of protein concentration. Colloids Surf B Biointerfaces 2020; 197:111407. [PMID: 33113491 DOI: 10.1016/j.colsurfb.2020.111407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 10/05/2020] [Accepted: 10/06/2020] [Indexed: 12/01/2022]
Abstract
This work was done to systematically elucidate the corrosion behavior of austenitic stainless steel subjected to various degree of cold deformation (10 %, 20 % & 30 %). The experiments were performed in phosphate buffer saline (PBS) solution having different concentrations of bovine serum albumin (0.2, 0.5, 1.0, 2.0, 4.0 g L-1). Potentiodynamic polarization tests and electrochemical impedance spectroscopy (EIS) analysis were performed to obtain the corrosion parameters. Scanning electron microscopy with energy dispersive X-ray (SEM-EDX), atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) were used to determine the surface morphologies and chemical compositions of the surface films. Contact angle analysis was also used to detect the hydrophilic character of sample surfaces. The BSA had a considerable effect of inhibition on the corrosion of SSs in annealed as well as in deformed state due to its adsorption on surface of steel. For annealed samples, at 4.0 g L-1BSA concentration, the corrosion resistance was drastically decreased but interestingly not for sample with more than 10 % deformation and the concentration effect of BSA is also not very significant after 0.5 g L-1 for deformed surfaces. The breakdown potential for 30 % deformed sample is quite higher in presence of BSA even at 4.0 g L-1 while it is lowest for annealed samples in the same condition. The variation in contact angle with deformation is very less after adsorption of BSA. On the basis of the obtained results, mechanism aspect for corrosion of steel in presence of protein is also deliberated.
Collapse
Affiliation(s)
- Mohd Talha
- School of New Energy and Materials, Southwest Petroleum University, Chengdu, 610500, Sichuan, PR China; State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University, Chengdu, 610500, Sichuan, PR China
| | - Yucong Ma
- School of New Energy and Materials, Southwest Petroleum University, Chengdu, 610500, Sichuan, PR China
| | - Yuanhua Lin
- School of New Energy and Materials, Southwest Petroleum University, Chengdu, 610500, Sichuan, PR China; State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University, Chengdu, 610500, Sichuan, PR China.
| | - A K Mandal
- Department of Metallurgical and Materials Engineering, National Institute of Technology, Durgapur, 713209, West Bengal, India
| | - O P Sinha
- Department of Metallurgical Engineering, Indian Institute of Technology (BHU), Varanasi, 221005, UP, India
| | - Xiangwei Kong
- School of Petroleum Engineering, Yangtze University, Wuhan, 434023, Hubei, China
| |
Collapse
|
10
|
Klok O, Igual Munoz A, Mischler S. An Overview of Serum Albumin Interactions with Biomedical Alloys. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E4858. [PMID: 33138286 PMCID: PMC7662596 DOI: 10.3390/ma13214858] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2020] [Revised: 10/25/2020] [Accepted: 10/27/2020] [Indexed: 01/23/2023]
Abstract
Understanding the interactions between biomedical alloys and body fluids is of importance for the successful and safe performance of implanted devices. Albumin, as the first protein that comes in contact with an implant surface, can determine the biocompatibility of biomedical alloys. The interaction of albumin with biomedical alloys is a complex process influenced by numerous factors. This literature overview aims at presenting the current understanding of the mechanisms of serum albumin (both Bovine Serum Albumin, BSA, and Human Serum Albumin, HSA) interactions with biomedical alloys, considering only those research works that present a mechanistic description of the involved phenomena. Widely used biomedical alloys, such as 316L steel, CoCrMo and Titanium alloys are specifically addressed in this overview. Considering the literature analysis, four albumin-related phenomena can be distinguished: adsorption, reduction, precipitation, and protein-metal binding. The experimental techniques used to understand and quantify those phenomena are described together with the studied parameters influencing them. The crucial effect of the electrochemical potential on those phenomena is highlighted. The effect of the albumin-related phenomena on corrosion behavior of biomedical materials also is discussed.
Collapse
Affiliation(s)
- Oksana Klok
- Tribology and Interfacial Chemistry Group, Ecole Polytechnique Fédérale de Lausanne (EPFL), 1015 Lausanne, Switzerland; (A.I.M.); (S.M.)
| | | | | |
Collapse
|
11
|
Atapour M, Wang X, Färnlund K, Odnevall Wallinder I, Hedberg Y. Corrosion and metal release investigations of selective laser melted 316L stainless steel in a synthetic physiological fluid containing proteins and in diluted hydrochloric acid. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2020.136748] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
12
|
Tiongson JKA, Aganda KCC, Bruzon DAV, Guevara AP, Basilia BA, Tapang GA, Martinez IS. Exploring the corrosion inhibition capability of FAP-based ionic liquids on stainless steel. ROYAL SOCIETY OPEN SCIENCE 2020; 7:200580. [PMID: 32874649 PMCID: PMC7428245 DOI: 10.1098/rsos.200580] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Accepted: 05/27/2020] [Indexed: 06/11/2023]
Abstract
Corrosion is clearly one of the more common causes of materials failure in stainless steel. To manage corrosion, chemical inhibitors are often used for prevention and control. Ionic liquids due to their hydrophobic and corrosion-resistant property are being explored as alternative protective coatings and anti-corrosion materials. In this particular study, ionic liquids containing functionalized imidazolium cations and tris(pentafluoroethyl)trifluorophosphate (FAP) anions were investigated for their ability to inhibit corrosion on stainless steel surfaces in acidic environment. Using surface characterization techniques, specifically scanning electron microscopy and energy-dispersive X-ray (EDX), the morphology and the elemental composition of the steel surfaces before and after corrosion were determined. Contact angle measurements were also performed to determine how these ionic liquids were able to wet the stainless steel surface. In addition, potentiodynamic studies were carried out to ensure that corrosion inhibition has occurred. Results show that these ionic liquids were able to inhibit corrosion on the stainless steel surfaces. This indicates promise in the use of these FAP-based ionic liquids for corrosion management in stainless steel.
Collapse
Affiliation(s)
- Julius Kim A. Tiongson
- Natural Sciences Research Institute, University of the Philippines Diliman, Quezon City 1101, Philippines
| | - Kim Christopher C. Aganda
- Advanced Device and Materials Testing Laboratory, Department of Science and Technology Compound, Gen. Santos Avenue, Bicutan, Taguig City 1631, Philippines
| | - Dwight Angelo V. Bruzon
- National Institute of Physics, University of the Philippines Diliman, Quezon City 1101, Philippines
| | - Albert P. Guevara
- Advanced Device and Materials Testing Laboratory, Department of Science and Technology Compound, Gen. Santos Avenue, Bicutan, Taguig City 1631, Philippines
| | - Blessie A. Basilia
- Advanced Device and Materials Testing Laboratory, Department of Science and Technology Compound, Gen. Santos Avenue, Bicutan, Taguig City 1631, Philippines
| | - Giovanni A. Tapang
- National Institute of Physics, University of the Philippines Diliman, Quezon City 1101, Philippines
| | - Imee Su Martinez
- Natural Sciences Research Institute, University of the Philippines Diliman, Quezon City 1101, Philippines
- Institute of Chemistry, University of the Philippines Diliman, Quezon City 1101, Philippines
| |
Collapse
|
13
|
Wang X, Odnevall Wallinder I, Hedberg Y. Bioaccessibility of Nickel and Cobalt Released from Occupationally Relevant Alloy and Metal Powders at Simulated Human Exposure Scenarios. Ann Work Expo Health 2020; 64:659-675. [PMID: 32320011 PMCID: PMC7328476 DOI: 10.1093/annweh/wxaa042] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/10/2019] [Revised: 02/29/2020] [Accepted: 04/02/2020] [Indexed: 11/12/2022] Open
Abstract
Nickel (Ni) and cobalt (Co) release from chromium-alloy powders (different stainless steels and a nickel-based Inconel alloy) compared with Ni and Co metal powders was investigated at simulated human exposure scenarios (ingestion, skin contact, and inhalation) between 2 and 168 h. All investigated powders consisted of particles sized within the respirable range. The powder particles and their surface reactivity were studied by means of nitrogen adsorption and electrochemical, spectroscopic (X-ray photoelectron spectroscopy and atomic absorption spectroscopy), light scattering, and microscopic techniques. The release of both Ni and Co was highest in the acidic and complexing fluids simulating the gastric environment and an inhalation scenario of small powders (artificial lysosomal fluid). Relatively high corrosion resistance and lower levels of released Ni and Co were observed in all fluids for all alloy powders compared with the corresponding pure metals. The extent of released metals was low for powders with a passive surface oxide. This study strongly emphasizes the importance of considering alloying effects in toxicological classification and/or regulation of Ni and Co in alloys and metals.
Collapse
Affiliation(s)
- Xuying Wang
- KTH Royal Institute of Technology, School of Engineering Sciences in Chemistry, Biotechnology and Health, Department of Chemistry, Division of Surface and Corrosion Science, Drottning Kristinas v. 51, Stockholm, Sweden
| | - Inger Odnevall Wallinder
- KTH Royal Institute of Technology, School of Engineering Sciences in Chemistry, Biotechnology and Health, Department of Chemistry, Division of Surface and Corrosion Science, Drottning Kristinas v. 51, Stockholm, Sweden
| | - Yolanda Hedberg
- KTH Royal Institute of Technology, School of Engineering Sciences in Chemistry, Biotechnology and Health, Department of Chemistry, Division of Surface and Corrosion Science, Drottning Kristinas v. 51, Stockholm, Sweden
| |
Collapse
|
14
|
Yavrukova VI, Shandurkov DN, Marinova KG, Kralchevsky PA, Ung YW, Petkov JT. Cleaning Ability of Mixed Solutions of Sulfonated Fatty Acid Methyl Esters. J SURFACTANTS DETERG 2020. [DOI: 10.1002/jsde.12393] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Affiliation(s)
- Veronika I. Yavrukova
- Department of Chemical and Pharmaceutical Engineering, Faculty of Chemistry and PharmacySofia University Sofia 1164 Bulgaria
| | - Dimitar N. Shandurkov
- Department of Chemical and Pharmaceutical Engineering, Faculty of Chemistry and PharmacySofia University Sofia 1164 Bulgaria
| | - Krastanka G. Marinova
- Department of Chemical and Pharmaceutical Engineering, Faculty of Chemistry and PharmacySofia University Sofia 1164 Bulgaria
| | - Peter A. Kralchevsky
- Department of Chemical and Pharmaceutical Engineering, Faculty of Chemistry and PharmacySofia University Sofia 1164 Bulgaria
| | - Yee W. Ung
- KLK OLEO, KL‐Kepong Oleomas Sdn Bhd, Menara KLK, Jalan PJU 7/6, Mutiara Damansara Petaling Jaya 47810 Selangor Dalur Ehsan Malaysia
| | - Jordan T. Petkov
- KLK OLEO, KL‐Kepong Oleomas Sdn Bhd, Menara KLK, Jalan PJU 7/6, Mutiara Damansara Petaling Jaya 47810 Selangor Dalur Ehsan Malaysia
| |
Collapse
|
15
|
Gaifulina R, Caruana DJ, Oukrif D, Guppy NJ, Culley S, Brown R, Bell I, Rodriguez-Justo M, Lau K, Thomas GMH. Rapid and complete paraffin removal from human tissue sections delivers enhanced Raman spectroscopic and histopathological analysis. Analyst 2020; 145:1499-1510. [PMID: 31894759 PMCID: PMC7677988 DOI: 10.1039/c9an01030k] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2019] [Accepted: 12/14/2019] [Indexed: 12/29/2022]
Abstract
Incomplete removal of paraffin and organic contaminants from tissues processed for diagnostic histology has been a profound barrier to the introduction of Raman spectroscopic techniques into clinical practice. We report a route to rapid and complete paraffin removal from a range of formalin-fixed paraffin embedded tissues using super mirror stainless steel slides. The method is equally effective on a range of human and animal tissues, performs equally well with archived and new samples and is compatible with standard pathology lab procedures. We describe a general enhancement of the Raman scatter and enhanced staining with antibodies used in immunohistochemistry for clinical diagnosis. We conclude that these novel slide substrates have the power to improve diagnosis through anatomical pathology by facilitating the simultaneous combination of improved, more sensitive immunohistochemical staining and simplified, more reliable Raman spectroscopic imaging, analysis and signal processing.
Collapse
Affiliation(s)
- Riana Gaifulina
- Department of Cell and Developmental Biology
, University College London
,
UK
.
; Tel: +44 (0)20 7679 6098
- Department of Chemistry
, University College London
,
UK
| | | | - Dahmane Oukrif
- Research Department of Pathology
, University College London
,
UK
| | - Naomi J. Guppy
- UCL Advanced Diagnostics
, University College Hospital
,
UK
| | - Siân Culley
- Department of Cell and Developmental Biology
, University College London
,
UK
.
; Tel: +44 (0)20 7679 6098
- MRC Laboratory for Molecular Cell Biology
, University College London
,
UK
| | - Robert Brown
- Spectroscopy Products Division
,
Renishaw plc
, UK
.
| | - Ian Bell
- Spectroscopy Products Division
,
Renishaw plc
, UK
.
| | - Manuel Rodriguez-Justo
- Department of Gastrointestinal Pathology
, University College Hospital and Department of Research Pathology/Cancer Institute
,
UCL
, UK
| | - Katherine Lau
- Spectroscopy Products Division
,
Renishaw plc
, UK
.
| | - Geraint M. H. Thomas
- Department of Cell and Developmental Biology
, University College London
,
UK
.
; Tel: +44 (0)20 7679 6098
| |
Collapse
|
16
|
Stainless steel in simulated milk and whey protein solutions – Influence of grade on corrosion and metal release. Electrochim Acta 2020. [DOI: 10.1016/j.electacta.2019.135428] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
17
|
Xu H, Hu T, Wang M, Zheng Y, Qin H, Cao H, An Z. Degradability and biocompatibility of magnesium-MAO: The consistency and contradiction between in-vitro and in-vivo outcomes. ARAB J CHEM 2020. [DOI: 10.1016/j.arabjc.2018.07.010] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022] Open
|
18
|
Atapour M, Wei Z, Chaudhary H, Lendel C, Odnevall Wallinder I, Hedberg Y. Metal release from stainless steel 316L in whey protein - And simulated milk solutions under static and stirring conditions. Food Control 2019. [DOI: 10.1016/j.foodcont.2019.02.031] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/27/2022]
|
19
|
Chekotu JC, Groarke R, O'Toole K, Brabazon D. Advances in Selective Laser Melting of Nitinol Shape Memory Alloy Part Production. MATERIALS 2019; 12:ma12050809. [PMID: 30857231 PMCID: PMC6427257 DOI: 10.3390/ma12050809] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/09/2019] [Revised: 02/27/2019] [Accepted: 02/28/2019] [Indexed: 11/16/2022]
Abstract
Nitinol (nickel-titanium or Ni-Ti) is the most utilized shape memory alloy due to its good superelasticity, shape memory effect, low stiffness, damping, biocompatibility, and corrosion resistance. Various material characteristics, such as sensitivity to composition and production thermal gradients, make conventional methods ineffective for the manufacture of high quality complex Nitinol components. These issues can be resolved by modern additive manufacturing (AM) methods which can produce net or near-net shape parts with highly precise and complex Nitinol structures. Compared to Laser Engineered Net Shape (LENS), Selective Laser Melting (SLM) has the benefit of more easily creating a high quality local inert atmosphere which protects chemically-reactive Nitinol powders to a higher degree. In this paper, the most recent publications related to the SLM processing of Nitinol are reviewed to identify the various influential factors involved and process-related issues. It is reported how powder quality and material composition have a significant effect on the produced microstructures and phase transformations. The effect of heat treatments after SLM fabrication on the functional and mechanical properties are noted. Optimization of several operating parameters were found to be critical in fabricating Nitinol parts of high density. The importance of processing parameters and related thermal cooling gradient which are crucial for obtaining the correct phase structure for shape memory capabilities are also presented. The paper concludes by presenting the significant findings and areas of prospective future research in relation to the SLM processing of Nitinol.
Collapse
Affiliation(s)
- Josiah Cherian Chekotu
- School of Mechanical & Manufacturing Engineering, Dublin City University, Dublin 9, Ireland.
- Advanced Processing Technology Research Centre, APT, Dublin City University, Dublin 9, Ireland.
- I-Form Advanced Manufacturing Research Centre, Dublin City University, Dublin 9, Ireland.
| | - Robert Groarke
- School of Mechanical & Manufacturing Engineering, Dublin City University, Dublin 9, Ireland.
- Advanced Processing Technology Research Centre, APT, Dublin City University, Dublin 9, Ireland.
- I-Form Advanced Manufacturing Research Centre, Dublin City University, Dublin 9, Ireland.
| | - Kevin O'Toole
- Exergyn, DCU Alpha, Old Finglas Road, Glasnevin, Dublin 11, Ireland.
| | - Dermot Brabazon
- School of Mechanical & Manufacturing Engineering, Dublin City University, Dublin 9, Ireland.
- Advanced Processing Technology Research Centre, APT, Dublin City University, Dublin 9, Ireland.
- I-Form Advanced Manufacturing Research Centre, Dublin City University, Dublin 9, Ireland.
| |
Collapse
|
20
|
Meier C, Weissbach R, Weinberg J, Wall WA, John Hart A. Modeling and characterization of cohesion in fine metal powders with a focus on additive manufacturing process simulations. POWDER TECHNOL 2019. [DOI: 10.1016/j.powtec.2018.11.072] [Citation(s) in RCA: 67] [Impact Index Per Article: 11.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
21
|
Talha M, Ma Y, Kumar P, Lin Y, Singh A. Role of protein adsorption in the bio corrosion of metallic implants - A review. Colloids Surf B Biointerfaces 2019; 176:494-506. [PMID: 30690385 DOI: 10.1016/j.colsurfb.2019.01.038] [Citation(s) in RCA: 69] [Impact Index Per Article: 11.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 12/14/2018] [Accepted: 01/19/2019] [Indexed: 11/15/2022]
Abstract
Implants are exposed to a complex physiological environment that contains various organic compounds, especially proteins. The adsorption of proteins has an immense influence on the corrosion, biocompatibility and wear properties of implantable metals. Proteins engage in multiple processes that could potentially inhibit or promote metal degradation, depending on the type of proteins, their concentration and the properties of the implant material. In the bio corrosion process, proteins are denatured and transform into a film on the metal surface, inhibiting corrosion. This film is found on many retrieved artificial joints, especially on worn areas, and can protect the passive film from scrapping due to its lubricating effect, thus decreasing tribocorroion. On the other hand, the interactions of metal ions with proteins (and amino acids) create colloidal organometallic complexes. Transport of the complex compounds away from the interface increases dissolution rates; thus, it accelerates the corrosion of metallic implants. The influence of protein adsorption on the corrosion behaviour of metallic biomaterials is presented in this review. Biocompatible metals that are favourably used as implants such as stainless steel, Co-Cr alloys, Ti alloys and biodegradable Mg and Fe alloys are specifically addressed. We have highlighted the adsorption phenomenon of protein on metallic implants, the interaction of proteins with metallic implants and the role of protein adsorption on implant biocorrosion behaviour as well as their wear resistance.
Collapse
Affiliation(s)
- Mohd Talha
- State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University, Chengdu, 610500, Sichuan, China; School of Materials Science and Engineering, Southwest Petroleum University, Chengdu, 610500, Sichuan, China
| | - Yucong Ma
- School of Materials Science and Engineering, Southwest Petroleum University, Chengdu, 610500, Sichuan, China
| | - Pardeep Kumar
- Department of Physics, Guru Jambheshwar University of Science and Technology, Hisar, 125001, Haryana, India
| | - Yuanhua Lin
- State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University, Chengdu, 610500, Sichuan, China; School of Materials Science and Engineering, Southwest Petroleum University, Chengdu, 610500, Sichuan, China.
| | - Ambrish Singh
- State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University, Chengdu, 610500, Sichuan, China; School of Materials Science and Engineering, Southwest Petroleum University, Chengdu, 610500, Sichuan, China
| |
Collapse
|
22
|
Kitte SA, Li S, Nsabimana A, Gao W, Lai J, Liu Z, Xu G. Stainless steel electrode for simultaneous stripping analysis of Cd(II), Pb(II), Cu(II) and Hg(II). Talanta 2019; 191:485-490. [DOI: 10.1016/j.talanta.2018.08.066] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/05/2018] [Revised: 08/19/2018] [Accepted: 08/27/2018] [Indexed: 10/28/2022]
|
23
|
Talha M, Ma Y, Lin Y, Singh A, Liu W, Kong X. Corrosion behaviour of austenitic stainless steels in phosphate buffer saline solution: synergistic effects of protein concentration, time and nitrogen. NEW J CHEM 2019; 43:1943-1955. [DOI: 10.1039/c8nj04670k] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
Adsorption of protein on a steel surface decreases the corrosion rate, while the formation of metal–protein complexes followed by detachment enhances the corrosion rate.
Collapse
Affiliation(s)
- Mohd Talha
- State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University
- Chengdu 610500
- China
- School of Materials Science and Engineering, Southwest Petroleum University
- Chengdu
| | - Yucong Ma
- School of Materials Science and Engineering, Southwest Petroleum University
- Chengdu
- China
| | - Yuanhua Lin
- State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University
- Chengdu 610500
- China
- School of Materials Science and Engineering, Southwest Petroleum University
- Chengdu
| | - Ambrish Singh
- State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation, Southwest Petroleum University
- Chengdu 610500
- China
- School of Materials Science and Engineering, Southwest Petroleum University
- Chengdu
| | - Wanying Liu
- School of Materials Science and Engineering, Southwest Petroleum University
- Chengdu
- China
| | - Xiangwei Kong
- School of Petroleum Engineering, Yangtze University
- Wuhan
- China
| |
Collapse
|
24
|
Ma Y, Talha M, Lin Y, Ituen E, Wang X, Liu W, Kong X. Eliminating the negative effect of cold deformation on the corrosion resistance of austenitic stainless steel in the presence of a protein. NEW J CHEM 2019; 43:13857-13862. [DOI: 10.1039/c9nj02058f] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
Interaction of proteins with stainless steel subjected to cold deformation. The presence of a protein overcomes the negative effect of martensite formation on corrosion due to its adsorption.
Collapse
Affiliation(s)
- Yucong Ma
- School of Materials Science and Engineering
- Southwest Petroleum University
- Chengdu
- China
| | - Mohd Talha
- School of Materials Science and Engineering
- Southwest Petroleum University
- Chengdu
- China
- State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation
| | - Yuanhua Lin
- School of Materials Science and Engineering
- Southwest Petroleum University
- Chengdu
- China
- State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation
| | - Ekemini Ituen
- School of Materials Science and Engineering
- Southwest Petroleum University
- Chengdu
- China
- State Key Laboratory of Oil and Gas Reservoir Geology and Exploitation
| | - Xiaohong Wang
- School of Materials Science and Engineering
- Southwest Petroleum University
- Chengdu
- China
| | - Wanying Liu
- School of Materials Science and Engineering
- Southwest Petroleum University
- Chengdu
- China
| | - Xiangwei Kong
- School of Petroleum Engineering
- Yangtze University
- Wuhan
- China
| |
Collapse
|
25
|
Hedberg YS, Žnidaršič M, Herting G, Milošev I, Odnevall Wallinder I. Mechanistic insight on the combined effect of albumin and hydrogen peroxide on surface oxide composition and extent of metal release from Ti6Al4V. J Biomed Mater Res B Appl Biomater 2018; 107:858-867. [PMID: 30102828 PMCID: PMC6586049 DOI: 10.1002/jbm.b.34182] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2018] [Revised: 05/03/2018] [Accepted: 05/28/2018] [Indexed: 11/06/2022]
Abstract
The titanium-aluminium (6 wt%)-vanadium (4 wt%) (Ti6Al4V) alloy is widely used as an orthopedic and dental implant material due to its high corrosion resistance in such environments. The corrosion resistance is usually determined by means of electrochemical methods, which may not be able to detect other chemical surface reactions. Literature findings report a synergistic effect of the combination of the abundant protein albumin and hydrogen peroxide (H2 O2 ) on the extent of metal release and corrosion of Ti6Al4V. The objectives of this study were to gain further mechanistic insight on the interplay of H2 O2 and albumin on the metal release process of Ti6Al4V with special focus on (1) kinetics and (2) H2 O2 and albumin concentrations. This was accomplished mainly by metal release and surface oxide composition investigations, which confirmed the combined effect of H2 O2 and albumin on the metal release process, although not detectable by electrochemical open circuit potential measurements. A concentration of 30 mM H2 O2 induced substantial changes in the surface oxide characteristics, an oxide which became thicker and enriched in aluminum. Bovine serum albumin (BSA) seemed to be able to deplete this aluminum content from the outermost surface or at least to delay its surface enrichment. This effect increased with increased BSA concentration, and for time periods longer than 24 h. This study hence suggests that short-term (accelerated) corrosion resistance measurements are not sufficient to predict potential health effects of Ti6Al4V alloys since also chemical dissolution mechanisms play a large role for metal release, possibly in a synergistic way. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 107B: 855-867, 2019.
Collapse
Affiliation(s)
- Yolanda S Hedberg
- Department of Chemistry, Division of Surface and Corrosion Science, KTH Royal Institute of Technology, Drottning Kristinas väg 51, SE-10044, Stockholm, Sweden
| | - Monika Žnidaršič
- Department of Chemistry, Division of Surface and Corrosion Science, KTH Royal Institute of Technology, Drottning Kristinas väg 51, SE-10044, Stockholm, Sweden.,Faculty of Chemistry and Chemical Technology, University of Ljubljana, Večna pot 113, SI-1000, Ljubljana, Slovenia
| | - Gunilla Herting
- Department of Chemistry, Division of Surface and Corrosion Science, KTH Royal Institute of Technology, Drottning Kristinas väg 51, SE-10044, Stockholm, Sweden
| | - Ingrid Milošev
- Department of Physical and Organic Chemistry, Jožef Stefan Institute, Jamova c. 39, SI-1000, Ljubljana, Slovenia
| | - Inger Odnevall Wallinder
- Department of Chemistry, Division of Surface and Corrosion Science, KTH Royal Institute of Technology, Drottning Kristinas väg 51, SE-10044, Stockholm, Sweden
| |
Collapse
|
26
|
Kitte SA, Zafar MN, Zholudov YT, Ma X, Nsabimana A, Zhang W, Xu G. Determination of Concentrated Hydrogen Peroxide Free from Oxygen Interference at Stainless Steel Electrode. Anal Chem 2018; 90:8680-8685. [PMID: 29923395 DOI: 10.1021/acs.analchem.8b02038] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
H2O2 is frequently used at high concentrations in various applications. It is very challenging to detect high concentrations of H2O2 and to eliminate oxygen interference for H2O2 detection through electrochemical reduction. In the present investigation, the electrochemistry of H2O2 at stainless steel electrode has been carried out for the first time. A cathodic peak for H2O2 reduction was observed at about -0.40 V, and no cathodic peak for dissolved oxygen reduction was observed on type 304 stainless steel electrode. Amperometric determination of H2O2 on type 304 stainless steel electrode displayed a linear range from 0.05 up to 733 mM with a detection limit of 0.02 mM (S/N = 3) and a sensitivity of 16.7 μA mM-1 cm-2. The type 304 stainless steel electrode not only shows much higher upper limit than other reported electrodes for the detection of concentrated H2O2 but also is free from oxygen interference, which is of great importance for practical applications. This method could detect H2O2 in wound wash and lake water with excellent recoveries. Moreover, we successfully applied the stainless steel electrode to determine glucose using glucose oxidase to catalyze the oxidation of glucose to generate hydrogen peroxide. The linear range for glucose is between 0.5 and 25 mM, which covers clinically important blood glucose concentrations well.
Collapse
Affiliation(s)
- Shimeles Addisu Kitte
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China.,University of Chinese Academy of Sciences , Beijing , 100049 , P.R. China.,Department of Chemistry, College of Natural Sciences , Jimma University , P.O. Box 378, Jimma , Ethiopia
| | - Muhammad Nadeem Zafar
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China.,Department of Chemistry , University of Gujrat , Gujrat , Punjab 50700 Pakistan
| | - Yuriy T Zholudov
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China.,Laboratory of Analytical Optochemotronics , Kharkiv National University of Radio Electronics , 14 Nauka Ave. , Kharkiv , 61166 , Ukraine
| | - Xiangui Ma
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China.,University of Chinese Academy of Sciences , Beijing , 100049 , P.R. China
| | - Anaclet Nsabimana
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China.,University of Chinese Academy of Sciences , Beijing , 100049 , P.R. China
| | - Wei Zhang
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China
| | - Guobao Xu
- State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry , Chinese Academy of Sciences , 5625 Renmin Street , Changchun , Jilin 130022 , P.R. China
| |
Collapse
|
27
|
Kim WJ, Jeong KO, Kang DH. Inhibition of Initial Attachment of Injured Salmonella Typhimurium onto Abiotic Surfaces. J Food Prot 2018; 81:37-42. [PMID: 29257724 DOI: 10.4315/0362-028x.jfp-17-209] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Following sanitation interventions in food processing facilities, sublethally injured bacterial cells can remain on food contact surfaces. We investigated whether injured Salmonella Typhimurium cells can attach onto abiotic surfaces, which is the initial stage for further biofilm development. We utilized heat, UV, hydrogen peroxide, and lactic acid treatments, which are widely utilized by the food industry. Our results showed that heat, UV, and hydrogen peroxide did not effectively change populations of attached Salmonella Typhimurium. Cells treated with hydrogen peroxide had a slightly higher tendency to adhere to abiotic surfaces, although there was no significant difference between the populations of control and hydrogen peroxide-treated cells. However, lactic acid effectively reduced the number of Salmonella Typhimurium cells attached to stainless steel. We also compared physicochemical changes of Salmonella Typhimurium after application of lactic acid and used hydrogen peroxide as a positive control because only lactic acid showed a decreased tendency for attachment and hydrogen peroxide induced slightly higher numbers of attached bacteria cells. Extracellular polymeric substance produced by Salmonella Typhimurium was not detected in any treatment. Significant differences in hydrophobicity were not observed. Surface charges of cell membranes did not show relevant correlation with numbers of attached cells, whereas autoaggregation showed a positive correlation with attachment to stainless steel. Our results highlight that when lactic acid is applied in a food processing facility, it can effectively interfere with adhesion of injured Salmonella Typhimurium cells onto food contact surfaces.
Collapse
Affiliation(s)
- Woo-Ju Kim
- 1 Department of Food and Animal Biotechnology, Department of Agricultural Biotechnology, Center for Food and Bioconvergence, and Research Institute for Agricultural and Life Sciences, Seoul National University, Seoul 08826, Republic of Korea; and
| | - Ki-Ok Jeong
- 1 Department of Food and Animal Biotechnology, Department of Agricultural Biotechnology, Center for Food and Bioconvergence, and Research Institute for Agricultural and Life Sciences, Seoul National University, Seoul 08826, Republic of Korea; and
| | - Dong-Hyun Kang
- 1 Department of Food and Animal Biotechnology, Department of Agricultural Biotechnology, Center for Food and Bioconvergence, and Research Institute for Agricultural and Life Sciences, Seoul National University, Seoul 08826, Republic of Korea; and.,2 Institutes of Green Bio Science and Technology, Seoul National University, Pyeongchang-gun, Gangwon-do, 25354, Republic of Korea
| |
Collapse
|
28
|
Kitte SA, Gao W, Zholudov YT, Qi L, Nsabimana A, Liu Z, Xu G. Stainless Steel Electrode for Sensitive Luminol Electrochemiluminescent Detection of H2O2, Glucose, and Glucose Oxidase Activity. Anal Chem 2017; 89:9864-9869. [DOI: 10.1021/acs.analchem.7b01939] [Citation(s) in RCA: 130] [Impact Index Per Article: 16.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Affiliation(s)
- Shimeles Addisu Kitte
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin 130022, People’s Republic of China
- University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| | - Wenyue Gao
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin 130022, People’s Republic of China
- University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| | - Yuriy T. Zholudov
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin 130022, People’s Republic of China
- Laboratory
of Analytical Optochemotronics, Kharkiv National University of Radio Electronics, 14 Nauka Avenue, Kharkiv 61166, Ukraine
| | - Liming Qi
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin 130022, People’s Republic of China
- University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| | - Anaclet Nsabimana
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin 130022, People’s Republic of China
- University of Chinese Academy of Sciences, Beijing 100049, People’s Republic of China
| | - Zhongyuan Liu
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin 130022, People’s Republic of China
| | - Guobao Xu
- State
Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin 130022, People’s Republic of China
| |
Collapse
|
29
|
Biofilm Formation on Stainless Steel by Streptococcus thermophilus UC8547 in Milk Environments Is Mediated by the Proteinase PrtS. Appl Environ Microbiol 2017; 83:AEM.02840-16. [PMID: 28159787 DOI: 10.1128/aem.02840-16] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Accepted: 01/26/2017] [Indexed: 11/20/2022] Open
Abstract
In Streptococcus thermophilus, gene transfer events and loss of ancestral traits over the years contribute to its high level of adaptation to milk environments. Biofilm formation capacity, a phenotype that is lost in the majority of strains, plays a role in persistence in dairy environments, such as milk pasteurization and cheese manufacturing plants. To investigate this property, we have studied S. thermophilus UC8547, a fast-acidifying dairy starter culture selected for its high capacity to form biofilm on stainless steel under environmental conditions resembling the dairy environment. Using a dynamic flow cell apparatus, it was shown that S. thermophilus UC8547 biofilm formation on stainless steel depends on the presence of milk proteins. From this strain, which harbors the prtS gene for the cell wall protease and shows an aggregative phenotype, spontaneous mutants with impaired biofilm capacity can be isolated at high frequency. These mutants lack the PrtS expendable island, as confirmed by comparison of the genome sequence of UC8547Δ3 with that of the parent strain. The prtS island excision occurs between two 26-bp direct repeats located in the two copies of the ISSth1 flanking this genomic island. The central role of PrtS was confirmed by analyzing the derivative strain UC8547Δ16, whose prtS gene was interrupted by an insertional mutation, thereby making it incapable of biofilm formation. PrtS, acting as a binding substance between the milk proteins adhered to stainless steel and S. thermophilus cell envelopes, mediates biofilm formation in dairy environments. This feature provides S. thermophilus with an ecological benefit for its survival and persistence in this environment.IMPORTANCE The increased persistence of S. thermophilus biofilm has consequences in the dairy environment: if, on the one hand, the release of this microorganism from biofilm can promote the fermentation of artisanal cheeses, under industrial conditions it may lead to undesirable contamination of dairy products. The study of the molecular mechanism driving S. thermophilus biofilm formation provides increased knowledge on how an ancestral trait affects relevant phenotypes, such as persistence in the environment and efficiency of growth in milk. This study provides insight into the genetic factors affecting biofilm formation at dairy plants.
Collapse
|
30
|
Abdolvahabi A, Shi Y, Rasouli S, Croom CM, Chuprin A, Shaw BF. How Do Gyrating Beads Accelerate Amyloid Fibrillization? Biophys J 2017; 112:250-264. [PMID: 28122213 PMCID: PMC5266089 DOI: 10.1016/j.bpj.2016.12.004] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2016] [Revised: 11/22/2016] [Accepted: 12/05/2016] [Indexed: 01/21/2023] Open
Abstract
The chemical and physical mechanisms by which gyrating beads accelerate amyloid fibrillization in microtiter plate assays are unclear. Identifying these mechanisms will help optimize high-throughput screening assays for molecules and mutations that modulate aggregation and might explain why different research groups report different rates of aggregation for identical proteins. This article investigates how the rate of superoxide dismutase-1 (SOD1) fibrillization is affected by 12 different beads with a wide range of hydrophobicity, mass, stiffness, and topology but identical diameter. All assays were performed on D90A apo-SOD1, which is a stable and wild-type-like variant of SOD1. The most significant and uniform correlation between any material property of each bead and that bead's effect on SOD1 fibrillization rate was with regard to bead mass. A linear correlation existed between bead mass and rate of fibril elongation (R2 = 0.7): heavier beads produced faster rates and shorter fibrils. Nucleation rates (lag time) also correlated with bead mass, but only for non-polymeric beads (i.e., glass, ceramic, metallic). The effect of bead mass on fibrillization correlated (R2 = 0.96) with variations in buoyant forces and contact forces (between bead and microplate well), and was not an artifact of residual momentum during intermittent gyration. Hydrophobic effects were observed, but only for polymeric beads: lag times correlated negatively with contact angle of water and degree of protein adhesion (surface adhesion and hydrophobic effects were negligible for non-polymeric beads). These results demonstrate that contact forces (alone) explain kinetic variation among non-polymeric beads, whereas surface hydrophobicity and contact forces explain kinetic variation among polymeric beads. This study also establishes conditions for high-throughput amyloid assays of SOD1 that enable the control over fibril morphologies and produce eightfold faster lag times and fourfold less stochasticity than in previous studies.
Collapse
Affiliation(s)
| | - Yunhua Shi
- Department of Chemistry and Biochemistry, Baylor University, Waco, Texas
| | - Sanaz Rasouli
- Department of Chemistry and Biochemistry, Baylor University, Waco, Texas; Institute of Biomedical Studies, Baylor University, Waco, Texas
| | - Corbin M Croom
- Department of Chemistry and Biochemistry, Baylor University, Waco, Texas
| | - Aleksandra Chuprin
- Department of Chemistry and Biochemistry, Baylor University, Waco, Texas
| | - Bryan F Shaw
- Department of Chemistry and Biochemistry, Baylor University, Waco, Texas.
| |
Collapse
|
31
|
Rezaei B, Shams-Ghahfarokhi L, Havakeshian E, Ensafi AA. An electrochemical biosensor based on nanoporous stainless steel modified by gold and palladium nanoparticles for simultaneous determination of levodopa and uric acid. Talanta 2016; 158:42-50. [DOI: 10.1016/j.talanta.2016.04.061] [Citation(s) in RCA: 58] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/01/2016] [Revised: 04/22/2016] [Accepted: 04/29/2016] [Indexed: 11/25/2022]
|
32
|
Metal release from stainless steel in biological environments: A review. Biointerphases 2016; 11:018901. [DOI: 10.1116/1.4934628] [Citation(s) in RCA: 77] [Impact Index Per Article: 8.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
|
33
|
da Silva Domingues JF, Roest S, Wang Y, van der Mei HC, Libera M, van Kooten TG, Busscher HJ. Macrophage phagocytic activity toward adhering staphylococci on cationic and patterned hydrogel coatings versus common biomaterials. Acta Biomater 2015; 18:1-8. [PMID: 25752975 DOI: 10.1016/j.actbio.2015.02.028] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2014] [Revised: 01/30/2015] [Accepted: 02/27/2015] [Indexed: 02/06/2023]
Abstract
Biomaterial-associated-infection causes failure of biomaterial implants. Many new biomaterials have been evaluated for their ability to inhibit bacterial colonization and stimulate tissue-cell-integration, but neglect the role of immune cells. This paper compares macrophage phagocytosis of adhering Staphylococcus aureus on cationic-coatings and patterned poly(ethylene)glycol-hydrogels versus common biomaterials and stainless steel in order to identify surface conditions that promote clearance of adhering bacteria. Staphylococci were allowed to adhere and grow on the materials in a parallel-plate-flow-chamber, after which murine macrophages were introduced. From the decrease in the number of adhering staphylococci, phagocytosis-rates were calculated, and total macrophage displacements during an experiment determined. Hydrophilic surfaces had the lowest phagocytosis-rates, while common biomaterials had intermediate phagocytosis-rates. Patterning of poly(ethylene)glycol-hydrogel coatings increased phagocytosis-rates to the level of common biomaterials, while on cationic-coatings phagocytosis-rates remained relatively low. Likely, phagocytosis-rates on cationic coatings are hampered relative to common biomaterials through strong electrostatic binding of negatively-charged macrophages and staphylococci. On polymeric biomaterials and glass, phagocytosis-rates increased with macrophage displacement, while both parameters increased with biomaterial surface hydrophobicity. Thus hydrophobicity is a necessary surface condition for effective phagocytosis. Concluding, next-generation biomaterials should account for surface effects on phagocytosis in order to enhance the ability of these materials to resist biomaterial-associated-infection.
Collapse
|
34
|
Wagener V, Faltz AS, Killian MS, Schmuki P, Virtanen S. Protein interactions with corroding metal surfaces: comparison of Mg and Fe. Faraday Discuss 2015; 180:347-60. [DOI: 10.1039/c4fd00253a] [Citation(s) in RCA: 49] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
The influence of bovine serum albumin (BSA) on the electrochemical behaviour of pure Mg and Fe was studied in simulated body fluid (SBF), in view of the possible application of these materials as biodegradable metals. Results indicate a different trend for the BSA-effect on corrosion for the two metals: for Mg, a strong corrosion-inhibiting effect is observed in the presence of BSA in solution, especially for short-term exposure, whereas for Fe only a slight acceleration of corrosion is caused by the addition of BSA to the solution. For both metals, the protein-effect on the electrochemical behaviour shows a complex time-dependence. Surface analysis indicates that stronger BSA adsorption takes place on Mg than on Fe. Moreover, adsorption experiments with BSA and a second protein (lysozyme) were conducted. The results are discussed in view of electrostatic interactions between differently charged metal oxide/hydroxide surfaces and proteins.
Collapse
Affiliation(s)
- Victoria Wagener
- Institute for Surface Science and Corrosion
- University of Erlangen-Nuremberg
- 91058 Erlangen
- Germany
| | - Anne-Sophie Faltz
- Institute for Surface Science and Corrosion
- University of Erlangen-Nuremberg
- 91058 Erlangen
- Germany
| | - Manuela S. Killian
- Institute for Surface Science and Corrosion
- University of Erlangen-Nuremberg
- 91058 Erlangen
- Germany
| | - Patrik Schmuki
- Institute for Surface Science and Corrosion
- University of Erlangen-Nuremberg
- 91058 Erlangen
- Germany
| | - Sannakaisa Virtanen
- Institute for Surface Science and Corrosion
- University of Erlangen-Nuremberg
- 91058 Erlangen
- Germany
| |
Collapse
|