1
|
Ozdogan A, Tosun B. Effects of repetitive firings on mechanical, optical, and phase formation changes of ceramic materials. J Prosthet Dent 2024; 132:230-240. [PMID: 36889999 DOI: 10.1016/j.prosdent.2023.02.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2022] [Revised: 02/02/2023] [Accepted: 02/02/2023] [Indexed: 03/09/2023]
Abstract
STATEMENT OF PROBLEM Studies are sparse on how rapid heating and cooling negatively affect optical properties, including color and transparency, and mechanical properties, including hardness and durability, that affect esthetics and shorten the clinical usage period of the ceramics. PURPOSE The purpose of this in vitro study was to determine the effects of repeated firing on the color difference, mechanical properties, and phase formation of different ceramic materials. MATERIAL AND METHODS A total of 160 disks (12×1.35 mm) were produced from 4 different ceramic materials: lithium disilicate glass-ceramic, zirconia-reinforced lithium silicate ceramic, zirconia core, and monolithic zirconia. Specimens from all groups were divided into 4 groups (n=10) with a different number of veneer porcelain firings (1 to 4) by simple randomization. After the firings, color measurement, X-ray diffraction analysis, environmental scanning electron micrograph analysis, surface roughness evaluation, Vickers hardness evaluation, and biaxial flexural strength tests were performed. Data were analyzed with analysis of variance (2-way ANOVA) (α=.05). RESULTS Repeated firing did not affect the flexural strength of the specimens in any of the groups (P>.05), while the color, surface roughness, and surface hardness were significantly affected (P<.05). The specimens fired 4 times showed the highest mean Vickers hardness and ΔE00 values but the lowest mean surface roughness values. Zirconia core specimens showed the highest mean ΔE00 and flexural strength values, and lithium disilicate glass-ceramic specimens had the highest mean Vickers hardness values. CONCLUSIONS The increase in the number of firings affected the color, mechanical properties, and phase formation of the specimens; this change differed according to the ceramic tested.
Collapse
Affiliation(s)
- Alper Ozdogan
- Associate Professor, Department of Prosthodontics, Faculty of Dentistry, Atatürk University, Erzurum, Turkey.
| | - Büsra Tosun
- Assistant Professor, Department of Prosthodontics, Faculty of Dentistry, Bolu Abant İzzet Baysal University, Bolu, Turkey
| |
Collapse
|
2
|
Hoffmann M, Coldea A, Dönmez MB, Meinen J, Stawarczyk B. Mechanical Properties of High- and Low-Fusing Zirconia Veneering Ceramics Fired on Different Trays and Substrates. MATERIALS (BASEL, SWITZERLAND) 2024; 17:2261. [PMID: 38793327 PMCID: PMC11123089 DOI: 10.3390/ma17102261] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2024] [Revised: 04/30/2024] [Accepted: 04/30/2024] [Indexed: 05/26/2024]
Abstract
This study aimed to evaluate the effect of ceramic type, firing tray, and firing substrate on the density, shrinkage, biaxial flexural strength, Martens' hardness, and elastic indentation modulus of zirconia veneering ceramics. Disk-shaped specimens were fabricated from a high-fusing (HFZ) and a low-fusing (STR) zirconia veneering ceramic. These specimens were then divided into 10 groups according to firing trays (round, small honeycomb-shaped, cordierite [RSC]; round, large honeycomb-shaped, aluminum oxide [RLA]; rectangular, plane, silicon nitride [RCPS]; round, plane, silicon nitride [RPS]; and rectangular, plane, calcium silicate [RCPC]) and firing substrates (firing cotton and platinum foil) used (n = 12). The density, shrinkage, biaxial flexural strength, Martens' hardness, and indentation modulus were measured, and analyzed with generalized linear model analysis (α = 0.05). The interaction between the ceramic type and firing substrate affected density (p < 0.001), and the other outcomes were affected by the interaction among all main factors (p ≤ 0.045). Higher density was observed with HFZ or platinum foil (p ≤ 0.007). RSC and RLA led to a higher density than RCPS within HFZ and led to the lowest density within STR (p ≤ 0.046). STR had a higher shrinkage (p < 0.001). RSC mostly led to a lower shrinkage of HFZ (p ≤ 0.045). The effect of ceramic type and firing substrates on the biaxial flexural strength, Martens' hardness, and indentation modulus was minimal while there was no clear trend on the effect of firing tray on these properties. Ceramic type, firing tray, and firing substrate affected the mechanical properties of the tested zirconia veneering ceramics. Firing the tested zirconia veneering ceramics over a round and small honeycomb-shaped cordierite firing tray with firing cotton mostly led to improved mechanical properties.
Collapse
Affiliation(s)
- Moritz Hoffmann
- Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, 80336 Munich, Germany; (M.H.); (A.C.); (J.M.); (B.S.)
| | - Andrea Coldea
- Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, 80336 Munich, Germany; (M.H.); (A.C.); (J.M.); (B.S.)
| | - Mustafa Borga Dönmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3010 Bern, Switzerland
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul 34010, Turkey
| | - John Meinen
- Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, 80336 Munich, Germany; (M.H.); (A.C.); (J.M.); (B.S.)
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, 80336 Munich, Germany; (M.H.); (A.C.); (J.M.); (B.S.)
| |
Collapse
|
3
|
Katada H, Inokoshi M, Kamijo S, Liu H, Xu K, Kawashita M, Yokoi T, Shimabukuro M, Minakuchi S. Effects of multiple firings on the translucency, crystalline phase, and mechanical strength of highly translucent zirconia. Dent Mater J 2024; 43:294-302. [PMID: 38432949 DOI: 10.4012/dmj.2023-255] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/05/2024]
Abstract
This study aimed to clarify the effects of multiple firings on the translucency, crystal structure, and mechanical strength of highly translucent zirconia. Four types of highly translucent zirconia (LAVA Esthetic, LAVA Plus, KATANA Zirconia STML, and KATANA Zirconia HTML) were fired three times at three different temperatures, and the translucency, crystal structure, and flexural strength were evaluated before and after firing. The translucency was statistically compared using repeated-measures analysis of variance; the zirconia phase composition was assessed using X-ray diffraction followed by Rietveld analysis; and the biaxial flexural strength was assessed using Weibull analysis. The translucency of LAVA Esthetic and KATANA Zirconia HTML decreased significantly after firing, and the crystal composition of LAVA Plus and KATANA Zirconia HTML changed after multiple firings, whereas multiple firings did not affect the biaxial flexural strength of any samples. Thus, multiple firings may affect the optical properties of highly translucent zirconia.
Collapse
Affiliation(s)
- Haruko Katada
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Masanao Inokoshi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Singo Kamijo
- Basic Oral Health Engineering, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Hengyi Liu
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Kaiqi Xu
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| | - Masakazu Kawashita
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University
| | - Taishi Yokoi
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University
| | - Masaya Shimabukuro
- Institute of Biomaterials and Bioengineering, Tokyo Medical and Dental University
| | - Shunsuke Minakuchi
- Department of Gerodontology and Oral Rehabilitation, Graduate School of Medical and Dental Sciences, Tokyo Medical and Dental University
| |
Collapse
|
4
|
Coldea A, Donmez MB, Stawarczyk B. Effect of final temperature and heating rate on the mechanical and optical properties of a zirconia veneering ceramic. J Mech Behav Biomed Mater 2024; 149:106235. [PMID: 37976995 DOI: 10.1016/j.jmbbm.2023.106235] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 11/07/2023] [Accepted: 11/08/2023] [Indexed: 11/19/2023]
Abstract
PURPOSE To evaluate the effect of firing temperature and heating rate on the volumetric shrinkage, translucency, flexural strength, hardness, and fracture toughness of a zirconia veneering ceramic. MATERIAL AND METHODS Zirconia veneering ceramic specimens (N = 45) with varying final temperatures (730 °C, 750 °C, and 770 °C) and heating rates (70 °C/min, 55 °C/min, and 40 °C/min) were fabricated (n = 5). Each specimen's shrinkage, translucency, flexural strength, hardness, and fracture toughness were determined. Two-way analysis of variance, Scheffé test, and Pearson's correlation analysis were used to evaluate data (α = 0.05). RESULTS The shrinkage (44.9 ± 3.1-47.5 ± 1.6 vol%) and flexural strength (74.1 ± 17.4-107.0 ± 27.1 MPa) were not affected by tested parameters (P ≥ 0.288). The interaction between the main factors affected the translucency, hardness, and fracture toughness of the specimens (P ≤ 0.007). Specimens with 770 °C final temperature and 70 °C/min heating rate had the lowest (21.8 ± 3.2 %) translucency (P ≤ 0.039). The hardness ranged between 4.98 ± 0.51 GPa (730 °C; 70 °C/min) and 5.60 ± 0.37 GPa (770 °C; 70 °C/min). Fracture toughness ranged between 0.54 ± 0.04 MPa√m and 0.67 ± 0.08 MPa√m with the highest values for specimens fired at 730 °C with 70 °C/min (P ≤ 0.001). There was a positive correlation between translucency and hardness (r = 0.335, P = 0.012), and a negative correlation between fracture toughness and all parameters other than shrinkage (translucency: r = -0.693/P < 0.001, flexural strength: r = -0.258/P = 0.046, hardness: r = -0.457/P < 0.001). CONCLUSIONS Heating rate and final temperature should be considered while fabricating veneered zirconia restorations with tested ceramic as they affected the translucency, hardness, and fracture toughness.
Collapse
Affiliation(s)
- Andrea Coldea
- Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, Munich, Germany
| | - Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul, Turkey; Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Bogna Stawarczyk
- Department of Prosthetic Dentistry, Dental School, Ludwig-Maximilians-Universität München, Munich, Germany
| |
Collapse
|
5
|
Subaşı MG, Çakmak G, Sert M, Yilmaz B. Effect of multiple firings on surface roughness and flexural strength of CAD-CAM ceramics. J Prosthet Dent 2022; 128:216.e1-216.e8. [PMID: 35788273 DOI: 10.1016/j.prosdent.2022.05.021] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/05/2021] [Revised: 05/23/2022] [Accepted: 05/24/2022] [Indexed: 10/17/2022]
Abstract
STATEMENT OF PROBLEM Knowledge on the effect of multiple firings on surface roughness and the flexural strength of different types of monolithic computer-aided design and computer-aided manufacturing (CAD-CAM) ceramics is limited. PURPOSE The purpose of this in vitro study was to evaluate the effect of multiple firings on the surface roughness and flexural strength of 4 different CAD-CAM ceramics after thermocycling. MATERIAL AND METHODS Four different CAD-CAM ceramics (Lava All Zirconia 3-mol yttria tetragonal zirconia polycrystal [3-YTZP] [Z], VITA SUPRINITY [S], IPS e.max CAD [EX], IPS Empress CAD [E]) (n=33) were wet-sectioned to form rectangular 18×4×1.2-mm specimens. After glaze application, the specimens were divided into 3 subgroups according to the number of firings (1, 2, and 4) (n=11). The specimens were thermocycled (10 000 cycles), and surface roughness and flexural strength values were measured (n=10). One additional specimen from each group was analyzed by using scanning electron microscopy (SEM). Data were analyzed by 2-way analysis of variance (ANOVA) and the Tukey honestly significance difference (HSD) test (α=.05). RESULTS According to the 2-way ANOVA, the material, number of firings, and the interaction between the material and number of firings affected the surface roughness (P<.001). For flexural strength, material (P<.001) and number of firings (P<.039) were found significant. Multiple firings (2 or 4 firings) affected the surface roughness of E (P<.001). Regardless of the number of firings, the Z material had the highest flexural strength (P<.001). Four firings affected the flexural strength values only for the Z material (P≤.005). CONCLUSIONS CAD-CAM ceramic type affected the surface roughness and flexural strength values. The surface roughness of E was lower when fired 2 or 4 times than when fired once. The flexural strength of Z was lower when fired 4 times than when fired once.
Collapse
Affiliation(s)
- Meryem Gülce Subaşı
- Associate Professor, Department of Prosthodontics, Kutahya Saglik Bilimleri University, Faculty of Dentistry, Kütahya, Turkey
| | - Gülce Çakmak
- Senior Research Associate, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland.
| | - Murat Sert
- Assistant Professor, Department of Medical Laboratory Techniques, Ankara Yildirim Beyazit University, Ankara, Turkey
| | - Burak Yilmaz
- Associate Professor, Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland; Associate Professor, Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland; Adjunct Professor, Division of Restorative and Prosthetic Dentistry, The Ohio State University University College of Dentistry, Columbus, Ohio
| |
Collapse
|
6
|
Hensel J, Reise M, Liebermann A, Buser R, Stawarczyk B. Impact of multiple firings on fracture load of veneered zirconia restorations. J Mech Behav Biomed Mater 2022; 130:105213. [DOI: 10.1016/j.jmbbm.2022.105213] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2022] [Revised: 03/23/2022] [Accepted: 03/26/2022] [Indexed: 11/17/2022]
|
7
|
Hensel J, Reise M, Liebermann A, Buser R, Stawarczyk B. Impact of multiple firings on thermal properties and bond strength of veneered zirconia restorations. J Mech Behav Biomed Mater 2022; 128:105134. [DOI: 10.1016/j.jmbbm.2022.105134] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2021] [Revised: 02/09/2022] [Accepted: 02/13/2022] [Indexed: 10/19/2022]
|
8
|
Al-Surkhi O, Hamad Z. Influence of firing temperature and duration on the hardness of dental zirconia for optimum selection of sintering conditions. J Appl Biomater Funct Mater 2022; 20:22808000221114218. [PMID: 35876066 DOI: 10.1177/22808000221114218] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022] Open
Abstract
OBJECTIVE In order to optimize the properties of dental zirconia, the sintering process involves firing zirconia to elevated temperatures for an extended time that can take several hours. The aim of this study is to investigate the effect of firing temperature and firing duration on the hardness of dental zirconia to indicate the optimum sintering conditions. METHODS Thirty-six zirconia specimens in shape of bars were randomly assigned to nine groups. The zirconia specimen groups were sintered using a sintering furnace with different firing temperatures (900°C, 1200°C, and 1800°C) and firing durations (6, 9, and 12 h). A total of 108 hardness measurements were conducted for all specimens (12 hardness readings per group). For each of the specimen groups, micro Vickers hardness test was performed using a load of 1 Kgf (9.807 N) and the Vickers hardness number was computed. Statistical analysis using Kruskal-Wallis test was conducted to examine the significant differences on Vickers hardness number HV among the specimen groups according to the firing parameters with 0.005 p-value used as an indicator. RESULTS Results suggest that there is an association between the increase in the hardness number and the increase in firing duration at a given firing temperature. The results also indicate that there is an association between the increase in the hardness number and increase in firing temperature at a given firing duration. CONCLUSIONS The greatest rate of hardness increase with time is associated with groups of firing temperature 1200°C. The highest rate of hardness increase with temperature happened during the first 6 h of sintering process. On the other hand, there is no significant increase in the hardness number when increasing the firing temperature beyond 1200°C.
Collapse
Affiliation(s)
- Omar Al-Surkhi
- Faculty of Engineering, Al-Quds University, Jerusalem, Palestine
| | - Zeina Hamad
- Faculty of Engineering, Al-Quds University, Jerusalem, Palestine
| |
Collapse
|
9
|
Shelar P, Abdolvand H, Butler S. On the behaviour of zirconia-based dental materials: A review. J Mech Behav Biomed Mater 2021; 124:104861. [PMID: 34600431 DOI: 10.1016/j.jmbbm.2021.104861] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 09/23/2021] [Accepted: 09/24/2021] [Indexed: 11/28/2022]
Abstract
Zirconia-based dental materials are extensively used in clinical practice due to their tooth-like appearance, biofunctionality, biocompatibility, and affordability. However, premature clinical failures of veneering porcelains raise a concern about their integrity. Extensive studies have been performed over a decade to resolve this issue, but it is challenging to reference all information effectively. A single source identifying the significance of potential parameters on material performance has not previously been available. An evidence-based meta-narrative review technique was used to review the characteristic parameters that can affect the overall behaviour of zirconia-based materials. Keywords were chosen to assess manuscripts based on scientific coherence with this paper's research objective. Online keyword searches were carried out on ScienceDirect, PubMed, and SAGE databases for relevant published manuscripts from year 1985-2020.261 out of 3170 identified manuscripts were included. A total of 10 parameters were identified and classified into the material, manufacturing, and geometric aspects. The effect of every parameter was reviewed on the performance of the material. A discrepancy in findings was observed and is attributed to the fact that there is no standard methodology. This review acts as a single source that summarizes various parameters' contribution to zirconia-based dental materials' performance. This review facilitates manufacturing improvements by accounting for every parameter's effect on overall performance.
Collapse
Affiliation(s)
- Prashant Shelar
- Department of Mechanical & Materials Engineering, Western University, London, Ontario, Canada
| | - Hamidreza Abdolvand
- Department of Mechanical & Materials Engineering, Western University, London, Ontario, Canada
| | - Sheila Butler
- Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada.
| |
Collapse
|
10
|
Machado PS, Pereira GKR, Rodrigues CDS, Guilardi LF, Valandro LF, Rippe MP. Fatigue behavior and colorimetric differences of a porcelain-veneered zirconia: effect of quantity and position of specimens during firing. J Prosthodont Res 2020; 65:202-207. [PMID: 33028795 DOI: 10.2186/jpr.jpor_2019_336] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
PURPOSE To evaluate the influence of quantity and positioning of veneered zirconia specimens during firing of porcelain on their fatigue performance and colorimetric differences. METHODS Bilayer discs (Ø=15 mm) were made, following ISO 6872 guidelines, using a Y-TZP core (yttria-stabilized tetragonal zirconia polycrystal ceramic; VITA In-Ceram YZ) and a feldspathic veneering material (VITA VM9), being both layers with 0.7 mm thickness. Y-TZP discs were sintered, the veneering material was applied over it, and the bilayer specimens were fired according to two factors (n=20): 'quantity' (1 or 5 samples per firing cycle; G1 and G5 groups respectively) and 'positioning' of the specimens inside the furnace (center or periphery of the refractory tray; G5C and G5P groups, respectively). The CIEL*a*b* parameters were recorded with a spectrophotometer and the color difference (ΔE 00 ) and translucency (TP 00 ) were calculated using CIEDE2000 equations. The step-stress fatigue test was performed with the veneer facing down (region of tensile stress concentration), 10 Hz frequency, initial tension of 20 MPa for 5,000 cycles, followed by steps of 10,000 cycles using a step size of 10 MPa, up to 100 MPa; data from strength and number of cycles for failure were recorded for statistical analysis. RESULTS Unacceptable color differences (ΔE 00 >1.8) were observed comparing G5C vs. G1 (quantity) and G5C vs. G5P (positioning), meanwhile translucency parameters were not affected. Besides, only the 'quantity' factor influenced the fatigue performance (G1>G5C). None of the tested specimens survived beyond 90N and/or 75000 cycles. CONCLUSIONS The quantity and position of the specimens during firing influence the final color of porcelain-veneered zirconia, and firing one specimen per cycle improved the fatigue performance of the bilayer system.
Collapse
Affiliation(s)
- Pablo Soares Machado
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria
| | - Gabriel Kalil Rocha Pereira
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria
| | - Camila da Silva Rodrigues
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria
| | - Luís Felipe Guilardi
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria
| | - Luiz Felipe Valandro
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria
| | - Marília Pivetta Rippe
- Post-Graduate Program in Oral Sciences (Prosthodontics Units), Faculty of Odontology, Federal University of Santa Maria (UFSM), Santa Maria
| |
Collapse
|
11
|
Zarone F, Di Mauro MI, Ausiello P, Ruggiero G, Sorrentino R. Current status on lithium disilicate and zirconia: a narrative review. BMC Oral Health 2019; 19:134. [PMID: 31272441 PMCID: PMC6610968 DOI: 10.1186/s12903-019-0838-x] [Citation(s) in RCA: 204] [Impact Index Per Article: 34.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2019] [Accepted: 06/27/2019] [Indexed: 01/28/2023] Open
Abstract
Background The introduction of the new generation of particle-filled and high strength ceramics, hybrid composites and technopolymers in the last decade has offered an extensive palette of dental materials broadening the clinical indications in fixed prosthodontics, in the light of minimally invasive dentistry dictates. Moreover, last years have seen a dramatic increase in the patients’ demand for non-metallic materials, sometimes induced by metal-phobia or alleged allergies. Therefore, the attention of scientific research has been progressively focusing on such materials, particularly on lithium disilicate and zirconia, in order to shed light on properties, indications and limitations of the new protagonists of the prosthetic scene. Methods This article is aimed at providing a narrative review regarding the state-of-the-art in the field of these popular ceramic materials, as to their physical-chemical, mechanical and optical properties, as well as to the proper dental applications, by means of scientific literature analysis and with reference to the authors’ clinical experience. Results A huge amount of data, sometimes conflicting, is available today. Both in vitro and in vivo studies pointed out the outstanding peculiarities of lithium disilicate and zirconia: unparalleled optical and esthetic properties, together with high biocompatibility, high mechanical resistance, reduced thickness and favorable wear behavior have been increasingly orientating the clinicians’ choice toward such ceramics. Conclusions The noticeable properties and versatility make lithium disilicate and zirconia materials of choice for modern prosthetic dentistry, requiring high esthetic and mechanical performances combined with a minimal invasive approach, so that the utilization of such metal-free ceramics has become more and more widespread over time.
Collapse
Affiliation(s)
- Fernando Zarone
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy
| | - Maria Irene Di Mauro
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy.
| | - Pietro Ausiello
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy
| | - Gennaro Ruggiero
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy
| | - Roberto Sorrentino
- Department of Neurosciences, Reproductive and Odontostomatological Sciences, University "Federico II" of Naples, Viale Pansini, 5 -, 80131, Naples, Italy
| |
Collapse
|
12
|
Do thermal treatments affect the mechanical behavior of porcelain-veneered zirconia? A systematic review and meta-analysis. Dent Mater 2019; 35:807-817. [PMID: 30846374 DOI: 10.1016/j.dental.2019.02.016] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Accepted: 02/13/2019] [Indexed: 11/21/2022]
Abstract
OBJECTIVES A systematic review of in vitro studies was conducted to assess the effect of thermal treatments on flexural strength or critical load to failure of porcelain-veneered zirconia (PVZ). SOURCES Literature searches were performed up to June 2018 in PubMed/MEDLINE, Scopus and Web of Science databases, with no publication year or language limits. DATA From 393 relevant studies, 21 were selected for full-text analysis, from which 7 failed to meet the inclusion criteria. The 14 remaining papers were included in the systematic review: 8 for meta-analysis and 6 restricted to descriptive analyses. Hand searching of reference lists resulted in no additional papers. STUDY SELECTION In vitro studies using PVZ specimens testing the influence of thermal treatments on the fracture resistance to monotonic or cyclic loading. Papers evaluating cooling rate were divided into those applying fast cooling from above the porcelain glass transition temperature (Tg), or from below it. Meta-analyses were performed separately for flexural strength and critical load to failure, using random effects at a 5% significance level. CONCLUSIONS Delaying furnace opening at a temperature below the porcelain Tg is advised for PVZ restorations, in order to improve their fracture resistance. Additional information is required to confirm the apparent beneficial effect of self-glaze and repeated veneer firings on the mechanical properties of these restorations. Finally, in order to obtain conclusive and relevant evidence regarding thermal treatments and the fracture resistance of PVZs, future studies should concentrate on anatomically-correct crown specimens.
Collapse
|
13
|
Lee HS, Kwon TY. The Application of a Novel Ceramic Liner Improves Bonding between Zirconia and Veneering Porcelain. MATERIALS 2017; 10:ma10091023. [PMID: 28869512 PMCID: PMC5615678 DOI: 10.3390/ma10091023] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/18/2017] [Revised: 08/29/2017] [Accepted: 08/31/2017] [Indexed: 11/16/2022]
Abstract
The adhesion of porcelain to zirconia is a key factor in the success of bilayered restorations. In this study, the efficacy of a novel experimental liner (EL) containing zirconia for improved bonding between zirconia and veneering porcelain was tested. Four ELs containing various concentrations (0, 3.0, 6.0, and 9.0 wt %) of zirconia were prepared. Testing determined the most effective EL (EL3 containing 3.0 wt % zirconia) in terms of shear bond strength value (n = 15). Three different bar-shaped zirconia/porcelain bilayer specimens were prepared for a three-point flexural strength (TPFS) test (n = 15): no-liner (NL), commercial liner (CL), and EL3. Specimens were tested for TPFS with the porcelain under tension and the maximum load was measured at the first sign of fracture. The strength data were analyzed using one-way ANOVA and Tukey's test (α = 0.05) as well as Weibull distribution. When compared to NL, the CL application had no effect, while the EL3 application had a significant positive effect (p < 0.001) on the flexural strength. Weibull analysis also revealed the highest shape and scale parameters for group EL3. Within the limitations of this study, the novel ceramic liner containing 3.0 wt % zirconia (EL3) significantly enhanced the zirconia/porcelain interfacial bonding.
Collapse
Affiliation(s)
- Hee-Sung Lee
- Department of Dental Science, Graduate School, Kyungpook National University, 2-188-1 Samduk-dong, Jung-gu, Daegu 700-412, Korea.
| | - Tae-Yub Kwon
- Department of Dental Biomaterials, School of Dentistry and Institute for Biomaterials Research & Development, Kyungpook National University, 2-188-1 Samduk-dong, Jung-gu, Daegu 700-412, Korea.
| |
Collapse
|