1
|
Mesny E, Leporq B, Chapet O, Beuf O. Intravoxel incoherent motion magnetic resonance imaging to assess early tumor response to radiation therapy: Review and future directions. Magn Reson Imaging 2024; 108:129-137. [PMID: 38354843 DOI: 10.1016/j.mri.2024.02.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2023] [Revised: 02/08/2024] [Accepted: 02/10/2024] [Indexed: 02/16/2024]
Abstract
Early prediction of radiation response by imaging is a dynamic field of research and it can be obtained using a variety of noninvasive magnetic resonance imaging methods. Recently, intravoxel incoherent motion (IVIM) has gained interest in cancer imaging. IVIM carries both diffusion and perfusion information, making it a promising tool to assess tumor response. Here, we briefly introduced the basics of IVIM, reviewed existing studies of IVIM in various type of tumors during radiotherapy in order to show whether IVIM is a useful technique for an early assessment of radiation response. 31/40 studies reported an increase of IVIM parameters during radiotherapy compared to baseline. In 27 studies, this increase was higher in patients with good response to radiotherapy. Future directions including implementation of IVIM on MR-Linac and its limitation are discussed. Obtaining new radiologic biomarkers of radiotherapy response could open the way for a more personalized, biology-guided radiation therapy.
Collapse
Affiliation(s)
- Emmanuel Mesny
- Radiation Oncology Department, Center Hospitalier Lyon Sud, Pierre Benite, France; Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1294, Lyon F-69100, France.
| | - Benjamin Leporq
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1294, Lyon F-69100, France
| | - Olivier Chapet
- Radiation Oncology Department, Center Hospitalier Lyon Sud, Pierre Benite, France
| | - Olivier Beuf
- Univ Lyon, INSA-Lyon, Université Claude Bernard Lyon 1, CNRS, Inserm, CREATIS UMR 5220, U1294, Lyon F-69100, France
| |
Collapse
|
2
|
Sample C, Wu J, Clark H. Image denoising and model-independent parameterization for IVIM MRI. Phys Med Biol 2024; 69:105001. [PMID: 38604177 DOI: 10.1088/1361-6560/ad3db8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2023] [Accepted: 04/11/2024] [Indexed: 04/13/2024]
Abstract
Objective. To improve intravoxel incoherent motion imaging (IVIM) magnetic resonance Imaging quality using a new image denoising technique and model-independent parameterization of the signal versusb-value curve.Approach. IVIM images were acquired for 13 head-and-neck patients prior to radiotherapy. Post-radiotherapy scans were also acquired for five of these patients. Images were denoised prior to parameter fitting using neural blind deconvolution, a method of solving the ill-posed mathematical problem of blind deconvolution using neural networks. The signal decay curve was then quantified in terms of several area under the curve (AUC) parameters. Improvements in image quality were assessed using blind image quality metrics, total variation (TV), and the correlations between parameter changes in parotid glands with radiotherapy dose levels. The validity of blur kernel predictions was assessed by the testing the method's ability to recover artificial 'pseudokernels'. AUC parameters were compared with monoexponential, biexponential, and triexponential model parameters in terms of their correlations with dose, contrast-to-noise (CNR) around parotid glands, and relative importance via principal component analysis.Main results. Image denoising improved blind image quality metrics, smoothed the signal versusb-value curve, and strengthened correlations between IVIM parameters and dose levels. Image TV was reduced and parameter CNRs generally increased following denoising.AUCparameters were more correlated with dose and had higher relative importance than exponential model parameters.Significance. IVIM parameters have high variability in the literature and perfusion-related parameters are difficult to interpret. Describing the signal versusb-value curve with model-independent parameters like theAUCand preprocessing images with denoising techniques could potentially benefit IVIM image parameterization in terms of reproducibility and functional utility.
Collapse
Affiliation(s)
- Caleb Sample
- Department of Physics and Astronomy, Faculty of Science, University of British Columbia, Vancouver, BC, CA, Canada
- Department of Medical Physics, BC Cancer, Surrey, BC, CA, Canada
| | - Jonn Wu
- Department of Radiation Oncology, BC Cancer, Vancouver, BC, CA, Canada
- Department of Surgery, Faculty of Medicine, University of British Columbia, Vancouver, BC, CA, Canada
| | - Haley Clark
- Department of Physics and Astronomy, Faculty of Science, University of British Columbia, Vancouver, BC, CA, Canada
- Department of Medical Physics, BC Cancer, Surrey, BC, CA, Canada
- Department of Surgery, Faculty of Medicine, University of British Columbia, Vancouver, BC, CA, Canada
| |
Collapse
|
3
|
Jiang YL, Li J, Zhang PF, Fan FX, Zou J, Yang P, Wang PF, Wang SY, Zhang J. Staging liver fibrosis with various diffusion-weighted magnetic resonance imaging models. World J Gastroenterol 2024; 30:1164-1176. [PMID: 38577177 PMCID: PMC10989501 DOI: 10.3748/wjg.v30.i9.1164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Revised: 01/15/2024] [Accepted: 02/07/2024] [Indexed: 03/06/2024] Open
Abstract
BACKGROUND Diffusion-weighted imaging (DWI) has been developed to stage liver fibrosis. However, its diagnostic performance is inconsistent among studies. Therefore, it is worth studying the diagnostic value of various diffusion models for liver fibrosis in one cohort. AIM To evaluate the clinical potential of six diffusion-weighted models in liver fibrosis staging and compare their diagnostic performances. METHODS This prospective study enrolled 59 patients suspected of liver disease and scheduled for liver biopsy and 17 healthy participants. All participants underwent multi-b value DWI. The main DWI-derived parameters included Mono-apparent diffusion coefficient (ADC) from mono-exponential DWI, intravoxel incoherent motion model-derived true diffusion coefficient (IVIM-D), diffusion kurtosis imaging-derived apparent diffusivity (DKI-MD), stretched exponential model-derived distributed diffusion coefficient (SEM-DDC), fractional order calculus (FROC) model-derived diffusion coefficient (FROC-D) and FROC model-derived microstructural quantity (FROC-μ), and continuous-time random-walk (CTRW) model-derived anomalous diffusion coefficient (CTRW-D) and CTRW model-derived temporal diffusion heterogeneity index (CTRW-α). The correlations between DWI-derived parameters and fibrosis stages and the parameters' diagnostic efficacy in detecting significant fibrosis (SF) were assessed and compared. RESULTS CTRW-D (r = -0.356), CTRW-α (r = -0.297), DKI-MD (r = -0.297), FROC-D (r = -0.350), FROC-μ (r = -0.321), IVIM-D (r = -0.251), Mono-ADC (r = -0.362), and SEM-DDC (r = -0.263) were significantly correlated with fibrosis stages. The areas under the ROC curves (AUCs) of the combined index of the six models for distinguishing SF (0.697-0.747) were higher than each of the parameters alone (0.524-0.719). The DWI models' ability to detect SF was similar. The combined index of CTRW model parameters had the highest AUC (0.747). CONCLUSION The DWI models were similarly valuable in distinguishing SF in patients with liver disease. The combined index of CTRW parameters had the highest AUC.
Collapse
Affiliation(s)
- Yan-Li Jiang
- Department of Magnetic Resonance Imaging, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
- Second Clinical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
- Gansu Province Clinical Research Center for Functional and Molecular Imaging, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
| | - Juan Li
- Department of Hepatology, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
| | - Peng-Fei Zhang
- Department of Magnetic Resonance Imaging, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
- Second Clinical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
| | - Feng-Xian Fan
- Department of Magnetic Resonance Imaging, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
- Gansu Province Clinical Research Center for Functional and Molecular Imaging, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
| | - Jie Zou
- Department of Magnetic Resonance Imaging, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
- Gansu Province Clinical Research Center for Functional and Molecular Imaging, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
| | - Pin Yang
- Department of Magnetic Resonance Imaging, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
- Gansu Province Clinical Research Center for Functional and Molecular Imaging, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
| | - Peng-Fei Wang
- Department of Magnetic Resonance Imaging, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
- Gansu Province Clinical Research Center for Functional and Molecular Imaging, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
| | - Shao-Yu Wang
- MR Scientific Marketing, Siemens Healthineers, Xi’an 710065, Shaanxi Province, China
| | - Jing Zhang
- Department of Magnetic Resonance Imaging, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
- Gansu Province Clinical Research Center for Functional and Molecular Imaging, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu Province, China
| |
Collapse
|
4
|
Vasquez JA, Brown M, Woolsey M, Abdul-Ghani M, Katabathina V, Deng S, Blangero J, Clarke GD. Reproducibility and Repeatability of Intravoxel Incoherent Motion MRI Acquisition Methods in Liver. J Magn Reson Imaging 2024. [PMID: 38240167 DOI: 10.1002/jmri.29249] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2023] [Revised: 01/08/2024] [Accepted: 01/09/2024] [Indexed: 02/07/2024] Open
Abstract
BACKGROUND Intravoxel incoherent motion (IVIM) diffusion weighted MRI (DWI) has potential for evaluating hepatic fibrosis but image acquisition technique influence on diffusion parameter estimation bears investigation. PURPOSE To minimize variability and maximize repeatably in abdominal DWI in terms of IVIM parameter estimates. STUDY TYPE Prospective test-retest and image quality comparison. SUBJECTS Healthy volunteers (3F/7M, 29.9 ± 12.9 years) and Family Study subjects (18F/12M, 51.7 ± 16.7 years), without and with liver steatosis. FIELD STRENGTH/SEQUENCE Abdominal single-shot echo-planar imaging (EPI) and simultaneous multi-slice (SMS) DWI sequences with respiratory triggering (RT), breath-holding (BH), and navigator echo (NE) at 3 Tesla. ASSESSMENT SMS-BH, EPI-NE, and SMS-RT data from twice-scanned healthy volunteers were analyzed using 6 × b-values (0-800 s⋅mm-2 ) and lower (LO) and higher (HI) b-value ranges. Family Study subjects were scanned using SMS and standard EPI sequences. The biexponential IVIM model was used to estimate fast-diffusion coefficient (Df ), fraction of fast diffusion (f), and slow-diffusion coefficient (Ds ). Scan time, estimated signal-to-noise ratio (eSNR), eSNR per acquisition, and distortion ratio were compared. STATISTICAL TESTS Coefficients of variation (CoV) and Bland Altman analyses were performed for test-retest repeatability. Interclass correlation coefficient (ICC) assessed interobserver agreement with P < 0.05 deemed significant. RESULTS Within-subject CoVs among volunteers (N = 10) for f and Ds were lowest in EPI-NE-LO (11.6%) and SMS-RT-HI (11.1%). Inter-observer ICCs for f and Ds were highest for EPI-NE-LO (0.63) and SMS-RT-LO (0.76). Df could not be estimated for most subjects. Estimated eSNR (EPI = 21.9, SMS = 4.7) and eSNR time (EPI = 6.7, SMS = 16.6) were greater for SMS, with less distortion in the liver region (DR-PE: EPI = 23.6, SMS = 13.1). DATA CONCLUSION Simultaneous multislice acquisitions had significantly less variability and higher ICCs of Ds , higher eSNR, less distortion, and reduced scan time compared to EPI. EVIDENCE LEVEL 2 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Juan A Vasquez
- Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
- Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| | - Marissa Brown
- Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
- Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| | - Mary Woolsey
- Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| | - Mohammad Abdul-Ghani
- Diabetes Division, Department of Medicine, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| | - Venkata Katabathina
- Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| | - Shengwen Deng
- Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| | - John Blangero
- Department of Human Genetics, School of Medicine, The University of Texas Rio Grande Valley, Brownsville, Texas, USA
| | - Geoffrey D Clarke
- Department of Radiology, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
- Research Imaging Institute, University of Texas Health Science Center at San Antonio, San Antonio, Texas, USA
| |
Collapse
|
5
|
Sharifzadeh Javidi S, Shirazinodeh A, Saligheh Rad H. Intravoxel Incoherent Motion Quantification Dependent on Measurement SNR and Tissue Perfusion: A Simulation Study. J Biomed Phys Eng 2023; 13:555-562. [PMID: 38148961 PMCID: PMC10749416 DOI: 10.31661/jbpe.v0i0.2102-1281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2020] [Accepted: 03/28/2021] [Indexed: 12/28/2023]
Abstract
Background The intravoxel incoherent motion (IVIM) model extracts both functional and structural information of a tissue using motion-sensitizing gradients. Objective The Objective of the present work is to investigate the impact of signal to noise ratio (SNR) and physiologic conditions on the validity of IVIM parameters. Material and Methods This study is a simulation study, modeling IVIM at a voxel, and also done 10,000 times for every single simulation. Complex noises with various standard deviations were added to signal in-silico to investigate SNR effects on output validity. Besides, some blood perfusion situations for different tissues were considered based on their physiological range to explore the impacts of blood fraction at each voxel on the validity of the IVIM outputs. Coefficient variation (CV) and bias of the estimations were computed to assess the validity of the IVIM parameters. Results This study has shown that the validity of IVIM output parameters highly depends on measurement SNR and physiologic characteristics of the studied organ. Conclusion IVIM imaging could be useful if imaging parameters are correctly selected for each specific organ, considering hardware limitations.
Collapse
Affiliation(s)
- Sam Sharifzadeh Javidi
- Department of Medical Physics and Biomedical Engineering, Medicine School, Tehran University of Medical Sciences, Tehran, Iran
- Quantitative Medical Imaging Systems Group, Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran
| | - Alireza Shirazinodeh
- Department of Medical Physics and Biomedical Engineering, Medicine School, Tehran University of Medical Sciences, Tehran, Iran
| | - Hamidreza Saligheh Rad
- Department of Medical Physics and Biomedical Engineering, Medicine School, Tehran University of Medical Sciences, Tehran, Iran
- Quantitative Medical Imaging Systems Group, Research Center for Molecular and Cellular Imaging, Tehran University of Medical Sciences, Tehran, Iran
| |
Collapse
|
6
|
Obara M, Kwon J, Yoneyama M, Ueda Y, Cauteren MV. Technical Advancements in Abdominal Diffusion-weighted Imaging. Magn Reson Med Sci 2023; 22:191-208. [PMID: 36928124 PMCID: PMC10086402 DOI: 10.2463/mrms.rev.2022-0107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/18/2023] Open
Abstract
Since its first observation in the 18th century, the diffusion phenomenon has been actively studied by many researchers. Diffusion-weighted imaging (DWI) is a technique to probe the diffusion of water molecules and create a MR image with contrast based on the local diffusion properties. The DWI pixel intensity is modulated by the hindrance the diffusing water molecules experience. This hindrance is caused by structures in the tissue and reflects the state of the tissue. This characteristic makes DWI a unique and effective tool to gain more insight into the tissue's pathophysiological condition. In the past decades, DWI has made dramatic technical progress, leading to greater acceptance in clinical practice. In the abdominal region, however, acquiring DWI with good quality is challenging because of several reasons, such as large imaging volume, respiratory and other types of motion, and difficulty in achieving homogeneous fat suppression. In this review, we discuss technical advancements from the past decades that help mitigate these problems common in abdominal imaging. We describe the use of scan acceleration techniques such as parallel imaging and compressed sensing to reduce image distortion in echo planar imaging. Then we compare techniques developed to mitigate issues due to respiratory motion, such as free-breathing, respiratory-triggering, and navigator-based approaches. Commonly used fat suppression techniques are also introduced, and their effectiveness is discussed. Additionally, the influence of the abovementioned techniques on image quality is demonstrated. Finally, we discuss the current and future clinical applications of abdominal DWI, such as whole-body DWI, simultaneous multiple-slice excitation, intravoxel incoherent motion, and the use of artificial intelligence. Abdominal DWI has the potential to develop further in the future, thanks to scan acceleration and image quality improvement driven by technological advancements. The accumulation of clinical proof will further drive clinical acceptance.
Collapse
Affiliation(s)
| | | | | | - Yu Ueda
- MR Clinical Science, Philips Japan Ltd
| | | |
Collapse
|
7
|
Zhou Y, Zheng J, Yang C, Peng J, Liu N, Yang L, Zhang XM. Application of intravoxel incoherent motion diffusion-weighted imaging in hepatocellular carcinoma. World J Gastroenterol 2022; 28:3334-3345. [PMID: 36158259 PMCID: PMC9346463 DOI: 10.3748/wjg.v28.i27.3334] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2021] [Revised: 04/26/2022] [Accepted: 06/26/2022] [Indexed: 02/06/2023] Open
Abstract
The morbidity and mortality of hepatocellular carcinoma (HCC) rank 6th and 4th, respectively, among malignant tumors worldwide. Traditional diffusion-weighted imaging (DWI) uses the apparent diffusion coefficient (ADC) obtained by applying the monoexponential model to reflect water molecule diffusion in active tissue; however, the value of ADC is affected by microcirculation perfusion. Using a biexponential model, intravoxel incoherent motion (IVIM)-DWI quantitatively measures information related to pure water molecule diffusion and microcirculation perfusion, thus compensating for the shortcomings of DWI. The number of studies examining the application of IVIM-DWI in patients with HCC has gradually increased over the last few years, and many results show that IVIM-DWI has vital value for HCC differentiation, pathological grading, and predicting and evaluating the treatment response. The present study principally reviews the principle of IVIM-DWI and its research progress in HCC differentiation, pathological grading, predicting and evaluating the treatment response, predicting postoperative recurrence and predicting gene expression prediction.
Collapse
Affiliation(s)
- Yi Zhou
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Medical Research Center, The Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
- Department of Radiology, People's Hospital of Deyang City, Deyang 618000, Sichuan Province, China
| | - Jing Zheng
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Medical Research Center, The Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Cui Yang
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Medical Research Center, The Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
- Department of Radiology, Panzhihua Central Hospital, Panzhihua 617000, Sichuan Province, China
| | - Juan Peng
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Medical Research Center, The Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
- Department of Radiology, Sichuan Provincial People's Hospital Jinniu Hospital, Chengdu Jinniu District People's Hospital, Chengdu 610007, Sichuan Province, China
| | - Ning Liu
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Medical Research Center, The Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Lin Yang
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Medical Research Center, The Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Xiao-Ming Zhang
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Medical Research Center, The Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| |
Collapse
|
8
|
Value of Intravoxel Incoherent Motion (IVIM) Imaging for Differentiation between Intrahepatic Cholangiocarcinoma and Hepatocellular Carcinoma. CONTRAST MEDIA & MOLECULAR IMAGING 2022; 2022:1504463. [PMID: 35615729 PMCID: PMC9113914 DOI: 10.1155/2022/1504463] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2022] [Revised: 03/21/2022] [Accepted: 04/22/2022] [Indexed: 12/19/2022]
Abstract
Efficient noninvasive imaging techniques in the differentiation of intrahepatic cholangiocarcinoma (ICC) and hepatocellular carcinoma (HCC) are very important because of their different management and prognosis. Our purpose was to evaluate the difference of parameters extracted from intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) between the two groups and their performance for the differentiation, as well as the significance of perfusion information. IVIM studies (9 b-values) in 41 patients with either ICC or HCC were reviewed retrospectively by two observers. Diffusion coefficient (D), pseudodiffusion coefficient (D∗), perfusion fraction (f), ADC, and the mean percentage of parenchymal enhancement (MPPE) at 30 s after contrast-enhancement were calculated and compared between ICC and HCC. The relationship between D∗, f values, and MPPE was evaluated by Spearman's correlation test. The diagnostic efficacy of all parameters was analyzed by the receiver operating characteristic (ROC) curve. Interobserver and intraobserver agreements were analyzed. The parameters (D and ADC) of ICC were distinctly higher than those of HCC; whereas the parameters (f and MPPE of arterial phase) were distinctly lower (all false discovery rate [FDR]-corrected P < 0.05). The metric D∗ value of ICC was slightly higher than that of HCC (71.44 vs 69.41) with FDR-corrected P > 0.05. Moreover, the value of parameter D was significantly lower than that of ADC (FDR-corrected P < 0.05). The parameters (D and f values) extracted from IVIM showed excellent diagnostic efficiency in the identification, and the diagnostic efficiency of D value was significantly higher than that of the ADC. There were positive correlations between perfusion-related parameters (D∗, f values) and MPPE. Interobserver and intraobserver agreements were excellent or perfect in measurements of all parameters. Parameters derived from IVIM were valuable for distinguishing ICC and HCC. Moreover, the D value showed better diagnostic efficiency for the differential diagnosis than monoexponential fitting-derived ADC value. Meanwhile, the significant correlation between perfusion-related parameters and MPPE demonstrates that specific IVIM metrics may serve as a noninvasive indicator for the vascular perfusion information of ICC and HCC.
Collapse
|
9
|
Egnell L, Jerome NP, Andreassen MMS, Bathen TF, Goa PE. Effects of echo time on IVIM quantifications of locally advanced breast cancer in clinical diffusion-weighted MRI at 3 T. NMR IN BIOMEDICINE 2022; 35:e4654. [PMID: 34967468 DOI: 10.1002/nbm.4654] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 09/21/2021] [Accepted: 10/10/2021] [Indexed: 06/14/2023]
Abstract
PURPOSE The purpose of this study was to investigate the effects of echo time dependence in IVIM quantification of the pseudo-diffusion fraction in breast cancer and whether correcting for the echo time dependence offers added clinical value. MATERIALS AND METHODS Fifteen patients with biopsy-proven breast cancer underwent a 3 T MRI examination with an extended DWI protocol at two different echo times (TE = 53 ms, b = 0, 50 s/mm2 ; TE = 77 ms, b = 0, 50, 120, 200, 400, 700 s/mm2 ). Volumes of interest were delineated around the tumors. In addition, simulated MRI data were generated for different levels of signal-to-noise ratio and two values for the blood T2 relaxation time (T2p = 100 ms and 150 ms). The pseudo-diffusion signal fraction was estimated from the simulated and in vivo tumor data using both the standard IVIM model and an extended IVIM model that accounts for the echo time dependence arising from distinct transverse relaxation times. RESULTS Simulations showed that the standard IVIM model overestimated the pseudo-diffusion fraction by 25% (T2p = 100 ms) and 60 % (T2p = 150 ms) (p < 0.0001 at SNR = 50). In vivo, the estimated apparent T2 value at b = 50 s/mm2 was around 8% lower than at b = 0 s/mm2 (p = 0.01) demonstrating a removal of the signal contribution from blood with long T2 associated with pseudo-diffusion. Using two different fixed values for T2p = 100, 150 ms, the pseudo-diffusion fraction was 15% and 46% higher in the standard model compared with the echo-time-corrected model (p < 0.01). CONCLUSION The standard IVIM model was found to overestimate the pseudo-diffusion fraction by 15% to 46% compared with the echo-time-corrected model in breast tumor DWI data acquired at 3 T. Our results suggest that a corrected model may give more accurate results in terms of signal fractions, but may not justify the added time needed to acquire the additional data in terms of clinical value.
Collapse
Affiliation(s)
- Liv Egnell
- Department of Physics, NTNU-Norwegian University of Science and Technology, Trondheim, Norway
- Clinic of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway
| | - Neil P Jerome
- Clinic of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway
- Department of Circulation and Medical Imaging, NTNU-Norwegian University of Science and Technology, Trondheim, Norway
| | - Maren M S Andreassen
- Department of Circulation and Medical Imaging, NTNU-Norwegian University of Science and Technology, Trondheim, Norway
| | - Tone F Bathen
- Clinic of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway
- Department of Circulation and Medical Imaging, NTNU-Norwegian University of Science and Technology, Trondheim, Norway
| | - Pål Erik Goa
- Department of Physics, NTNU-Norwegian University of Science and Technology, Trondheim, Norway
- Clinic of Radiology and Nuclear Medicine, St. Olav's University Hospital, Trondheim, Norway
| |
Collapse
|
10
|
Granata V, Fusco R, Belli A, Borzillo V, Palumbo P, Bruno F, Grassi R, Ottaiano A, Nasti G, Pilone V, Petrillo A, Izzo F. Conventional, functional and radiomics assessment for intrahepatic cholangiocarcinoma. Infect Agent Cancer 2022; 17:13. [PMID: 35346300 PMCID: PMC8961950 DOI: 10.1186/s13027-022-00429-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Accepted: 03/18/2022] [Indexed: 02/08/2023] Open
Abstract
Background This paper offers an assessment of diagnostic tools in the evaluation of Intrahepatic Cholangiocarcinoma (ICC). Methods Several electronic datasets were analysed to search papers on morphological and functional evaluation in ICC patients. Papers published in English language has been scheduled from January 2010 to December 2021.
Results We found that 88 clinical studies satisfied our research criteria. Several functional parameters and morphological elements allow a truthful ICC diagnosis. The contrast medium evaluation, during the different phases of contrast studies, support the recognition of several distinctive features of ICC. The imaging tool to employed and the type of contrast medium in magnetic resonance imaging, extracellular or hepatobiliary, should change considering patient, departement, and regional features. Also, Radiomics is an emerging area in the evaluation of ICCs. Post treatment studies are required to evaluate the efficacy and the safety of therapies so as the patient surveillance. Conclusions Several morphological and functional data obtained during Imaging studies allow a truthful ICC diagnosis.
Collapse
|
11
|
Simchick G, Geng R, Zhang Y, Hernando D. b value and first-order motion moment optimized data acquisition for repeatable quantitative intravoxel incoherent motion DWI. Magn Reson Med 2022; 87:2724-2740. [PMID: 35092092 DOI: 10.1002/mrm.29165] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2021] [Revised: 01/03/2022] [Accepted: 01/04/2022] [Indexed: 12/12/2022]
Abstract
PURPOSE To design a b value and first-order motion moment (M1 ) optimized data acquisition for repeatable intravoxel incoherent motion (IVIM) quantification in the liver. METHODS Cramer-Rao lower bound optimization was performed to determine optimal monopolar and optimal 2D samplings of the b-M1 space based on noise performance. Monte Carlo simulations were used to evaluate the bias and variability in estimates obtained using the proposed optimal samplings and conventional monopolar sampling. Diffusion MRI of the liver was performed in 10 volunteers using 3 IVIM acquisitions: conventional monopolar, optimized monopolar, and b-M1 -optimized gradient waveforms (designed based on the optimal 2D sampling). IVIM parameter maps of diffusion coefficient, perfusion fraction, and blood velocity SD were obtained using nonlinear least squares fitting. Noise performance (SDs), stability (outlier percentage), and test-retest or scan-rescan repeatability (intraclass correlation coefficients) were evaluated and compared across acquisitions. RESULTS Cramer-Rao lower bound and Monte Carlo simulations demonstrated improved noise performance of the optimal 2D sampling in comparison to monopolar samplings. Evaluating the designed b-M1 -optimized waveforms in healthy volunteers, significant decreases (p < 0.05) in the SDs and outlier percentages were observed for measurements of diffusion coefficient, perfusion fraction, and blood velocity SD in comparison to measurements obtained using monopolar samplings. Good-to-excellent repeatability (intraclass correlation coefficients ≥ 0.77) was observed for all 3 parameters in both the right and left liver lobes using the b-M1 -optimized waveforms. CONCLUSIONS 2D b-M1 -optimized data acquisition enables repeatable IVIM quantification with improved noise performance. 2D acquisitions may advance the establishment of IVIM quantitative biomarkers for liver diseases.
Collapse
Affiliation(s)
- Gregory Simchick
- Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Ruiqi Geng
- Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Yuxin Zhang
- Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| | - Diego Hernando
- Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin, USA.,Radiology, University of Wisconsin-Madison, Madison, Wisconsin, USA
| |
Collapse
|
12
|
Epstein SC, Bray TJP, Hall-Craggs MA, Zhang H. Task-driven assessment of experimental designs in diffusion MRI: A computational framework. PLoS One 2021; 16:e0258442. [PMID: 34624064 PMCID: PMC8500429 DOI: 10.1371/journal.pone.0258442] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Accepted: 09/27/2021] [Indexed: 11/23/2022] Open
Abstract
This paper proposes a task-driven computational framework for assessing diffusion MRI experimental designs which, rather than relying on parameter-estimation metrics, directly measures quantitative task performance. Traditional computational experimental design (CED) methods may be ill-suited to experimental tasks, such as clinical classification, where outcome does not depend on parameter-estimation accuracy or precision alone. Current assessment metrics evaluate experiments’ ability to faithfully recover microstructural parameters rather than their task performance. The method we propose addresses this shortcoming. For a given MRI experimental design (protocol, parameter-estimation method, model, etc.), experiments are simulated start-to-finish and task performance is computed from receiver operating characteristic (ROC) curves and associated summary metrics (e.g. area under the curve (AUC)). Two experiments were performed: first, a validation of the pipeline’s task performance predictions against clinical results, comparing in-silico predictions to real-world ROC/AUC; and second, a demonstration of the pipeline’s advantages over traditional CED approaches, using two simulated clinical classification tasks. Comparison with clinical datasets validates our method’s predictions of (a) the qualitative form of ROC curves, (b) the relative task performance of different experimental designs, and (c) the absolute performance (AUC) of each experimental design. Furthermore, we show that our method outperforms traditional task-agnostic assessment methods, enabling improved, more useful experimental design. Our pipeline produces accurate, quantitative predictions of real-world task performance. Compared to current approaches, such task-driven assessment is more likely to identify experimental designs that perform well in practice. Our method is not limited to diffusion MRI; the pipeline generalises to any task-based quantitative MRI application, and provides the foundation for developing future task-driven end-to end CED frameworks.
Collapse
Affiliation(s)
- Sean C. Epstein
- Department of Computer Science & Centre for Medical Image Computing, University College London, London, United Kingdom
- * E-mail:
| | - Timothy J. P. Bray
- Centre for Medical Imaging, University College London, London, United Kingdom
| | | | - Hui Zhang
- Department of Computer Science & Centre for Medical Image Computing, University College London, London, United Kingdom
| |
Collapse
|
13
|
Signal to noise and b-value analysis for optimal intra-voxel incoherent motion imaging in the brain. PLoS One 2021; 16:e0257545. [PMID: 34555054 PMCID: PMC8459980 DOI: 10.1371/journal.pone.0257545] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2021] [Accepted: 09/06/2021] [Indexed: 11/28/2022] Open
Abstract
Intravoxel incoherent motion (IVIM) is a method that can provide quantitative information about perfusion in the human body, in vivo, and without contrast agent. Unfortunately, the IVIM perfusion parameter maps are known to be relatively noisy in the brain, in particular for the pseudo-diffusion coefficient, which might hinder its potential broader use in clinical applications. Therefore, we studied the conditions to produce optimal IVIM perfusion images in the brain. IVIM imaging was performed on a 3-Tesla clinical system in four healthy volunteers, with 16 b values 0, 10, 20, 40, 80, 110, 140, 170, 200, 300, 400, 500, 600, 700, 800, 900 s/mm2, repeated 20 times. We analyzed the noise characteristics of the trace images as a function of b-value, and the homogeneity of the IVIM parameter maps across number of averages and sub-sets of the acquired b values. We found two peaks of noise of the trace images as function of b value, one due to thermal noise at high b-value, and one due to physiological noise at low b-value. The selection of b value distribution was found to have higher impact on the homogeneity of the IVIM parameter maps than the number of averages. Based on evaluations, we suggest an optimal b value acquisition scheme for a 12 min scan as 0 (7), 20 (4), 140 (19), 300 (9), 500 (19), 700 (1), 800 (4), 900 (1) s/mm2.
Collapse
|
14
|
Granata V, Grassi R, Fusco R, Belli A, Cutolo C, Pradella S, Grazzini G, La Porta M, Brunese MC, De Muzio F, Ottaiano A, Avallone A, Izzo F, Petrillo A. Diagnostic evaluation and ablation treatments assessment in hepatocellular carcinoma. Infect Agent Cancer 2021; 16:53. [PMID: 34281580 PMCID: PMC8287696 DOI: 10.1186/s13027-021-00393-0] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2021] [Accepted: 07/06/2021] [Indexed: 02/07/2023] Open
Abstract
This article provides an overview of diagnostic evaluation and ablation treatment assessment in Hepatocellular Carcinoma (HCC). Only studies, in the English language from January 2010 to January 202, evaluating the diagnostic tools and assessment of ablative therapies in HCC patients were included. We found 173 clinical studies that satisfied the inclusion criteria.HCC may be noninvasively diagnosed by imaging findings. Multiphase contrast-enhanced imaging is necessary to assess HCC. Intravenous extracellular contrast agents are used for CT, while the agents used for MRI may be extracellular or hepatobiliary. Both gadoxetate disodium and gadobenate dimeglumine may be used in hepatobiliary phase imaging. For treatment-naive patients undergoing CT, unenhanced imaging is optional; however, it is required in the post treatment setting for CT and all MRI studies. Late arterial phase is strongly preferred over early arterial phase. The choice of modality (CT, US/CEUS or MRI) and MRI contrast agent (extracelllar or hepatobiliary) depends on patient, institutional, and regional factors. MRI allows to link morfological and functional data in the HCC evaluation. Also, Radiomics is an emerging field in the assessment of HCC patients.Postablation imaging is necessary to assess the treatment results, to monitor evolution of the ablated tissue over time, and to evaluate for complications. Post- thermal treatments, imaging should be performed at regularly scheduled intervals to assess treatment response and to evaluate for new lesions and potential complications.
Collapse
Affiliation(s)
- Vincenza Granata
- Division of Radiology, Istituto Nazionale Tumori IRCCS Fondazione Pascale - IRCCS di Napoli, Naples, Italy
| | - Roberta Grassi
- Division of Radiology, Università degli Studi della Campania Luigi Vanvitelli, Naples, Italy
- Italian Society of Medical and Interventional Radiology SIRM, SIRM Foundation, Milan, Italy
| | | | - Andrea Belli
- Division of Hepatobiliary Surgical Oncology, Istituto Nazionale Tumori IRCCS Fondazione Pascale - IRCCS di Napoli, Naples, Italy
| | - Carmen Cutolo
- Department of Medicine, Surgery and Dentistry, University of Salerno, Salerno, Italy
| | - Silvia Pradella
- Radiology Division, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | - Giulia Grazzini
- Radiology Division, Azienda Ospedaliero-Universitaria Careggi, Florence, Italy
| | | | - Maria Chiara Brunese
- Department of Medicine and Health Sciences "Vincenzo Tiberio", University of Molise, Campobasso, Italy
| | - Federica De Muzio
- Department of Medicine and Health Sciences "Vincenzo Tiberio", University of Molise, Campobasso, Italy
| | - Alessandro Ottaiano
- Abdominal Oncology Division, Istituto Nazionale Tumori IRCCS Fondazione Pascale - IRCCS di Napoli, Naples, Italy
| | - Antonio Avallone
- Abdominal Oncology Division, Istituto Nazionale Tumori IRCCS Fondazione Pascale - IRCCS di Napoli, Naples, Italy
| | - Francesco Izzo
- Division of Hepatobiliary Surgical Oncology, Istituto Nazionale Tumori IRCCS Fondazione Pascale - IRCCS di Napoli, Naples, Italy
| | - Antonella Petrillo
- Division of Radiology, Istituto Nazionale Tumori IRCCS Fondazione Pascale - IRCCS di Napoli, Naples, Italy
| |
Collapse
|
15
|
Alyami AS, Williams HG, Argyriou K, Gunn D, Wilkinson-Smith V, White JR, Alyami J, Gowland PA, Moran GW, Hoad CL. Test-retest assessment of non-contrast MRI sequences to characterise and quantify the small bowel wall in healthy participants. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2021; 34:791-804. [PMID: 34089407 PMCID: PMC8578109 DOI: 10.1007/s10334-021-00931-2] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/15/2021] [Revised: 05/10/2021] [Accepted: 05/18/2021] [Indexed: 11/08/2022]
Abstract
Objective Quantitative Magnetic Resonance Imaging sequences have been investigated as objective imaging biomarkers of fibrosis and inflammation in Crohn’s disease. Aim To determine the repeatability and inter- and intra-observer agreement of these measures in the prepared small bowel wall. Methods Ten healthy participants were scanned at 3 T on 2 separate occasions using T1 and T2 relaxometry, IVIM-DWI and MT sequences. Test–retest repeatability was assessed using the coefficient of variation (CoV) and intra-class correlation coefficients (ICCs) were used to evaluate the intra- and inter-observer agreement Results Test–retest repeatability in the bowel wall was excellent for apparent diffusion coefficient (ADC), magnetisation transfer ratio (MTR), T1, and diffusion coefficient D (CoV 5%, 7%, 8%, and 10%, respectively), good for perfusion fraction (PF) (CoV 20%) and acceptable for T2 (CoV 21%). Inter-observer agreement was good for the T2, D and ADC (ICC = 0.89, 0.86, 0.76, respectively) and moderate for T1 (ICC = 0.55). Intra-observer agreement was similar to inter-observer agreement. Discussion This study showed variable results between the different parameters measured. Test–retest repeatability was at least acceptable for all parameters except pseudo-diffusion coefficient D*. Good inter- and intra-observer agreement was obtained for T2, ADC and D, with these parameters performing best in this technical validation study.
Collapse
Affiliation(s)
- Ali S Alyami
- Faculty of Applied Medical Sciences, Diagnostic Radiology, Jazan University, Jazan, Saudi Arabia.,School of Medicine, University of Nottingham, Nottingham, UK.,Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | - Hannah G Williams
- School of Medicine, University of Nottingham, Nottingham, UK.,Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK
| | - Konstantinos Argyriou
- National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK
| | - David Gunn
- School of Medicine, University of Nottingham, Nottingham, UK.,National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK
| | - Victoria Wilkinson-Smith
- School of Medicine, University of Nottingham, Nottingham, UK.,National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK
| | - Jonathan R White
- School of Medicine, University of Nottingham, Nottingham, UK.,National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK
| | - Jaber Alyami
- Diagnostic Radiology Department, Faculty of Applied Medical Sciences, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Penny A Gowland
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK.,National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK
| | - Gordon W Moran
- School of Medicine, University of Nottingham, Nottingham, UK.,National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK
| | - Caroline L Hoad
- Sir Peter Mansfield Imaging Centre, School of Physics and Astronomy, University of Nottingham, Nottingham, UK. .,National Institute for Health Research (NIHR) Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK.
| |
Collapse
|
16
|
A study of the correlations between IVIM-DWI parameters and the histologic differentiation of hepatocellular carcinoma. Sci Rep 2021. [PMID: 34001962 DOI: 10.1038/s41598-021-89784-2.pmid:] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/08/2023] Open
Abstract
The present study aimed to investigate the value of intravoxel incoherent motion diffusion weighted imaging (IVIM-DWI) in the preoperative prediction of the histologic differentiation of hepatocellular carcinoma (HCC). Seventy HCC patients were scanned with a 3.0 T magnetic resonance scanner. The values of apparent diffusion coefficient (ADC), slow apparent diffusion coefficient (D), fast apparent diffusion coefficient (D*), and the fraction of the fast apparent diffusion coefficient (f) were measured. Analysis of variance was used to compare the differences in parameters between groups with different degrees of histologic differentiation. p < 0.05 was considered statistically significant. Receiver operating characteristic (ROC) curves were used to analyse the efficacy of IVIM-DWI parameters for predicting the histologic differentiation of HCC. The ADC and D values for well, moderately and poorly differentiated HCC were 1.35 ± 0.17 × 10-3 mm2/s, 1.16 ± 0.17 × 10-3 mm2/s, 0.98 ± 0.21 × 10-3 mm2/s, and 1.06 ± 0.15 × 10-3 mm2/s, 0.88 ± 0.16 × 10-3 mm2/s, 0.76 ± 0.18 × 10-3 mm2/s, respectively, and all differences were significant. The D* and f values of the three groups were 32.87 ± 14.70 × 10-3 mm2/s, 41.68 ± 17.90 × 10-3 mm2/s, 34.54 ± 18.60 × 10-3 mm2/s and 0.22 ± 0.07, 0.23 ± 0.08, 0.18 ± 0.07, respectively, with no significant difference. When the cut-off values of ADC and D were 1.25 × 10-3 mm2/s and 0.97 × 10-3 mm2/s, respectively, their diagnostic sensitivities and specificities for distinguishing well differentiated HCC from moderately differentiated and poorly differentiated HCC were 73.3%, 85.5%, 86.7%, and 78.2%, and their areas under the ROC curve were 0.821 and 0.841, respectively. ADC and D values can be used preoperatively to predict the degree of histologic differentiation in HCC, and the D value has better diagnostic value.
Collapse
|
17
|
Zhou Y, Yang G, Gong XQ, Tao YY, Wang R, Zheng J, Yang C, Peng J, Yang L, Li JD, Zhang XM. A study of the correlations between IVIM-DWI parameters and the histologic differentiation of hepatocellular carcinoma. Sci Rep 2021; 11:10392. [PMID: 34001962 PMCID: PMC8129092 DOI: 10.1038/s41598-021-89784-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2021] [Accepted: 04/30/2021] [Indexed: 02/07/2023] Open
Abstract
The present study aimed to investigate the value of intravoxel incoherent motion diffusion weighted imaging (IVIM-DWI) in the preoperative prediction of the histologic differentiation of hepatocellular carcinoma (HCC). Seventy HCC patients were scanned with a 3.0 T magnetic resonance scanner. The values of apparent diffusion coefficient (ADC), slow apparent diffusion coefficient (D), fast apparent diffusion coefficient (D*), and the fraction of the fast apparent diffusion coefficient (f) were measured. Analysis of variance was used to compare the differences in parameters between groups with different degrees of histologic differentiation. p < 0.05 was considered statistically significant. Receiver operating characteristic (ROC) curves were used to analyse the efficacy of IVIM-DWI parameters for predicting the histologic differentiation of HCC. The ADC and D values for well, moderately and poorly differentiated HCC were 1.35 ± 0.17 × 10−3 mm2/s, 1.16 ± 0.17 × 10−3 mm2/s, 0.98 ± 0.21 × 10−3 mm2/s, and 1.06 ± 0.15 × 10−3 mm2/s, 0.88 ± 0.16 × 10−3 mm2/s, 0.76 ± 0.18 × 10−3 mm2/s, respectively, and all differences were significant. The D* and f values of the three groups were 32.87 ± 14.70 × 10−3 mm2/s, 41.68 ± 17.90 × 10−3 mm2/s, 34.54 ± 18.60 × 10−3 mm2/s and 0.22 ± 0.07, 0.23 ± 0.08, 0.18 ± 0.07, respectively, with no significant difference. When the cut-off values of ADC and D were 1.25 × 10−3 mm2/s and 0.97 × 10−3 mm2/s, respectively, their diagnostic sensitivities and specificities for distinguishing well differentiated HCC from moderately differentiated and poorly differentiated HCC were 73.3%, 85.5%, 86.7%, and 78.2%, and their areas under the ROC curve were 0.821 and 0.841, respectively. ADC and D values can be used preoperatively to predict the degree of histologic differentiation in HCC, and the D value has better diagnostic value.
Collapse
Affiliation(s)
- Yi Zhou
- Medical Imaging Key Laboratory of Sichuan Province, Medical Research Center, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, Sichuan, People's Republic of China.,Department of Radiology, People's Hospital of Deyang City, Deyang, 618000, Sichuan, People's Republic of China
| | - Gang Yang
- Institute of Hepato-Biliary-Intestinal Disease, Department of Hepatobiliary Surgery, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, Sichuan, People's Republic of China
| | - Xue-Qin Gong
- Medical Imaging Key Laboratory of Sichuan Province, Medical Research Center, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, Sichuan, People's Republic of China
| | - Yun-Yun Tao
- Medical Imaging Key Laboratory of Sichuan Province, Medical Research Center, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, Sichuan, People's Republic of China
| | - Ran Wang
- Medical Imaging Key Laboratory of Sichuan Province, Medical Research Center, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, Sichuan, People's Republic of China
| | - Jing Zheng
- Medical Imaging Key Laboratory of Sichuan Province, Medical Research Center, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, Sichuan, People's Republic of China
| | - Cui Yang
- Medical Imaging Key Laboratory of Sichuan Province, Medical Research Center, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, Sichuan, People's Republic of China
| | - Juan Peng
- Medical Imaging Key Laboratory of Sichuan Province, Medical Research Center, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, Sichuan, People's Republic of China
| | - Lin Yang
- Medical Imaging Key Laboratory of Sichuan Province, Medical Research Center, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, Sichuan, People's Republic of China.
| | - Jing-Dong Li
- Institute of Hepato-Biliary-Intestinal Disease, Department of Hepatobiliary Surgery, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, Sichuan, People's Republic of China
| | - Xiao-Ming Zhang
- Medical Imaging Key Laboratory of Sichuan Province, Medical Research Center, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, 637000, Sichuan, People's Republic of China
| |
Collapse
|
18
|
Association between IVIM parameters and treatment response in locally advanced squamous cell cervical cancer treated by chemoradiotherapy. Eur Radiol 2021; 31:7845-7854. [PMID: 33786654 DOI: 10.1007/s00330-021-07817-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2020] [Revised: 01/07/2021] [Accepted: 02/19/2021] [Indexed: 12/21/2022]
Abstract
OBJECTIVE To examine the associations of intravoxel incoherent motion (IVIM) parameters with treatment response in cervical cancer following concurrent chemoradiotherapy (CCRT). MATERIALS AND METHODS Forty-five patients, median age of 58 years (range: 28-82), with pre-CCRT and post-CCRT MRI, were retrospectively analysed. The IVIM parameters pure diffusion coefficient (D) and perfusion fraction (f) were estimated using the full b-value distribution (BVD) as well as an optimised subsample BVD. Dice similarity coefficient (DSC) and intraclass correlation coefficient (ICC) were used to measure observer repeatability in tumour delineation at both time points. Treatment response was determined by the response evaluation criteria in solid tumour (RECIST) 1.1 between MRI examinations. Mann-Whitney U tests were used to test for significant differences in IVIM parameters between treatment response groups. RESULTS Pre-CCRT tumour delineation repeatability was good (DSC = 0.81) while post-CCRT delineation repeatability was moderate (DSC = 0.67). Values of D and f had good repeatability at both time points (ICC > 0.80). Pre-CCRT f estimated using the full BVD and optimised subsample BVD were found to be significantly higher in patients with partial response compared to those with stable disease or disease progression (p = 0.01 and 95% CI = -0.02-0.00 for both cases). CONCLUSION Pre-CCRT f was associated with treatment response in cervical cancer with good observer repeatability. Similar discriminative ability was also observed in estimated pre-CCRT f from an optimised subsample BVD. KEY POINTS • Pre-treatment tumour delineation and IVIM parameters had good observer repeatability. • Post-treatment tumour delineation was worse than at pre-treatment, but IVIM parameters retained good ICC. • Pre-treatment perfusion fraction estimated from all b-values and an optimised subsample of b-values were associated with treatment response.
Collapse
|
19
|
Lee W, Kim B, Park H. Quantification of intravoxel incoherent motion with optimized b-values using deep neural network. Magn Reson Med 2021; 86:230-244. [PMID: 33594783 DOI: 10.1002/mrm.28708] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/09/2020] [Revised: 01/12/2021] [Accepted: 01/13/2021] [Indexed: 12/17/2022]
Abstract
PURPOSE To develop a framework for quantifying intravoxel incoherent motion (IVIM) parameters, where a neural network for quantification and b-values for diffusion-weighted imaging are simultaneously optimized. METHOD A deep neural network (DNN) method is proposed for accurate quantification of IVIM parameters from multiple diffusion-weighted images. In addition, optimal b-values are selected to acquire the multiple diffusion-weighted images. The proposed framework consists of an MRI signal generation part and an IVIM parameter quantification part. Monte-Carlo (MC) simulations were performed to evaluate the accuracy of the IVIM parameter quantification and the efficacy of b-value optimization. In order to analyze the effect of noise on the optimized b-values, simulations were performed with five different noise levels. For in vivo data, diffusion images were acquired with the b-values from four b-values selection methods for five healthy volunteers at 3T MRI system. RESULTS Experiment results showed that both the optimization of b-values and the training of DNN were simultaneously performed to quantify IVIM parameters. We found that the accuracies of the perfusion coefficient (Dp ) and perfusion fraction (f) were more sensitive to b-values than the diffusion coefficient (D) was. Furthermore, when the noise level changed, the optimized b-values also changed. Therefore, noise level has to be considered when optimizing b-values for IVIM quantification. CONCLUSION The proposed scheme can simultaneously optimize b-values and train DNN to minimize quantification errors of IVIM parameters. The trained DNN can quantify IVIM parameters from the diffusion-weighted images obtained with the optimized b-values.
Collapse
Affiliation(s)
- Wonil Lee
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - Byungjai Kim
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| | - HyunWook Park
- Department of Electrical Engineering, Korea Advanced Institute of Science and Technology, Daejeon, Republic of Korea
| |
Collapse
|
20
|
Zheng J, Gong XQ, Tao YY, Wang R, Yang G, Li JD, Ren T, Li ZM, Yang C, Wang WC, Yang L, Zhang XM. A Correlative Study Between IVIM-DWI Parameters and the Expression Levels of Ang-2 and TKT in Hepatocellular Carcinoma. Front Oncol 2021; 10:594366. [PMID: 33520706 PMCID: PMC7845759 DOI: 10.3389/fonc.2020.594366] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Accepted: 11/23/2020] [Indexed: 02/05/2023] Open
Abstract
Background Noninvasive evaluation of the expression of angiopoietin-2 (Ang-2) and transketolase (TKT) in hepatocellular carcinoma (HCC) is of great significance for the clinical development of individualized treatment plans. However, the correlation between intravoxel incoherent motion diffusion weighted imaging (IVIM-DWI) and the expression of Ang-2 and TKT has not been reported. We sought to investigate the correlations between IVIM-DWI parameters and Ang-2 and TKT expression levels in HCCs. Methods Conventional non-enhanced magnetic resonance imaging (MRI) and IVIM-DWI and dynamic contrast MRI were performed for 61 patients with HCC before surgical treatment. Various IVIM-DWI parameters, such as apparent diffusion coefficient (ADC), slow apparent diffusion coefficient (D), fast apparent diffusion coefficient (D*) and fraction of fast apparent diffusion coefficient (f), were calculated using Function-MADC software. Expression levels of Ang-2 and TKT in HCC were detected via immunohistochemical staining and classified into two grades. Independent sample t tests were used to compare differences in parameters between the two groups. The Spearman rank correlation test was used to analyze the correlations between IVIM-DWI parameters and Ang-2 and TKT expression levels in HCCs. Results The D* and f values were significantly higher in the high Ang-2 group than in the low Ang-2 group; there were no obvious between-group differences in ADC and D. Ang-2 expression was positively correlated with D* and f but not with ADC and D. The ADC and D values were significantly lower in the high TKT group than in the low TKT group, whereas the between-group differences for D* and f were not significant. TKT expression was negatively correlated with ADC and D but not with D* and f. Conclusions IVIM-DWI can be used to evaluate Ang-2 and TKT expression in HCC.
Collapse
Affiliation(s)
- Jing Zheng
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Xue Qin Gong
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Yun Yun Tao
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Ran Wang
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Gang Yang
- Institute of Hepato-Biliary-Intestinal Disease, Department of Hepatobiliary Surgery, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Jing Dong Li
- Institute of Hepato-Biliary-Intestinal Disease, Department of Hepatobiliary Surgery, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Tian Ren
- Department of Medical Record Statistics, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Zu Mao Li
- Department of Pathology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Cui Yang
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Wei Cheng Wang
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Lin Yang
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| | - Xiao Ming Zhang
- Medical Imaging Key Laboratory of Sichuan Province, Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, China
| |
Collapse
|
21
|
Perucho JAU, Chang HCC, Vardhanabhuti V, Wang M, Becker AS, Wurnig MC, Lee EYP. B-Value Optimization in the Estimation of Intravoxel Incoherent Motion Parameters in Patients with Cervical Cancer. Korean J Radiol 2020; 21:218-227. [PMID: 31997597 PMCID: PMC6992446 DOI: 10.3348/kjr.2019.0232] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2019] [Accepted: 10/30/2019] [Indexed: 12/25/2022] Open
Abstract
Objective This study aimed to find the optimal number of b-values for intravoxel incoherent motion (IVIM) imaging analysis, using simulated and in vivo data from cervical cancer patients. Materials and Methods Simulated data were generated using literature pooled means, which served as reference values for simulations. In vivo data from 100 treatment-naïve cervical cancer patients with IVIM imaging (13 b-values, scan time, 436 seconds) were retrospectively reviewed. A stepwise b-value fitting algorithm calculated optimal thresholds. Feed forward selection determined the optimal subsampled b-value distribution for biexponential IVIM fitting, and simplified IVIM modeling using monoexponential fitting was attempted. IVIM parameters computed using all b-values served as reference values for in vivo data. Results In simulations, parameters were accurately estimated with six b-values, or three b-values for simplified IVIM, respectively. In vivo data showed that the optimal threshold was 40 s/mm2 for patients with squamous cell carcinoma and a subsampled acquisition of six b-values (scan time, 198 seconds) estimated parameters were not significantly different from reference parameters (individual parameter error rates of less than 5%). In patients with adenocarcinoma, the optimal threshold was 100 s/mm2, but an optimal subsample could not be identified. Irrespective of the histological subtype, only three b-values were needed for simplified IVIM, but these parameters did not retain their discriminative ability. Conclusion Subsampling of six b-values halved the IVIM scan time without significant losses in accuracy and discriminative ability. Simplified IVIM is possible with only three b-values, at the risk of losing diagnostic information.
Collapse
Affiliation(s)
| | | | | | - Mandi Wang
- Department of Diagnostic Radiology, The University of Hong Kong, Hong Kong
| | - Anton Sebastian Becker
- Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, Switzerland
| | - Moritz Christoph Wurnig
- Institute of Diagnostic and Interventional Radiology, University Hospital of Zurich, Switzerland
| | | |
Collapse
|
22
|
Tao YY, Zhou Y, Wang R, Gong XQ, Zheng J, Yang C, Yang L, Zhang XM. Progress of intravoxel incoherent motion diffusion-weighted imaging in liver diseases. World J Clin Cases 2020; 8:3164-3176. [PMID: 32874971 PMCID: PMC7441263 DOI: 10.12998/wjcc.v8.i15.3164] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/26/2020] [Revised: 06/11/2020] [Accepted: 07/14/2020] [Indexed: 02/05/2023] Open
Abstract
Traditional magnetic resonance (MR) diffusion-weighted imaging (DWI) uses a single exponential model to obtain the apparent diffusion coefficient to quantitatively reflect the diffusion motion of water molecules in living tissues, but it is affected by blood perfusion. Intravoxel incoherent motion (IVIM)-DWI utilizes a double-exponential model to obtain information on pure water molecule diffusion and microcirculatory perfusion-related diffusion, which compensates for the insufficiency of traditional DWI. In recent years, research on the application of IVIM-DWI in the diagnosis and treatment of hepatic diseases has gradually increased and has achieved considerable progress. This study mainly reviews the basic principles of IVIM-DWI and related research progress in the diagnosis and treatment of hepatic diseases.
Collapse
Affiliation(s)
- Yun-Yun Tao
- Sichuan Key Laboratory of Medical Imaging, Department of Radiology and Medical Research Center of Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Yi Zhou
- Sichuan Key Laboratory of Medical Imaging, Department of Radiology and Medical Research Center of Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Ran Wang
- Sichuan Key Laboratory of Medical Imaging, Department of Radiology and Medical Research Center of Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Xue-Qin Gong
- Sichuan Key Laboratory of Medical Imaging, Department of Radiology and Medical Research Center of Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Jing Zheng
- Sichuan Key Laboratory of Medical Imaging, Department of Radiology and Medical Research Center of Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Cui Yang
- Sichuan Key Laboratory of Medical Imaging, Department of Radiology and Medical Research Center of Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Lin Yang
- Sichuan Key Laboratory of Medical Imaging, Department of Radiology and Medical Research Center of Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| | - Xiao-Ming Zhang
- Sichuan Key Laboratory of Medical Imaging, Department of Radiology and Medical Research Center of Affiliated Hospital of North Sichuan Medical College, Nanchong 637000, Sichuan Province, China
| |
Collapse
|
23
|
Ye Z, Wei Y, Chen J, Yao S, Song B. Value of intravoxel incoherent motion in detecting and staging liver fibrosis: A meta-analysis. World J Gastroenterol 2020; 26:3304-3317. [PMID: 32684744 PMCID: PMC7336331 DOI: 10.3748/wjg.v26.i23.3304] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/30/2019] [Revised: 03/26/2020] [Accepted: 05/28/2020] [Indexed: 02/06/2023] Open
Abstract
BACKGROUND Liver fibrosis (LF) is a common pathological feature of all chronic liver diseases. With the accumulation of extracellular matrix in the fibrotic liver, true molecular water diffusion and perfusion-related diffusion are restricted. Intravoxel incoherent motion (IVIM) can capture the information on tissue diffusivity and microcapillary perfusion separately and reflect the fibrotic severity with diffusion coefficients.
AIM To investigate the diagnostic performance of IVIM in detecting and staging LF with histology as a reference standard.
METHODS A comprehensive literature search was conducted to identify studies on the diagnostic accuracy of IVIM for assessment of histologically proven LF. The stages of LF were classified as F0 (no fibrosis), F1 (portal fibrosis without septa), F2 (periportal fibrosis with few septa), F3 (septal fibrosis), and F4 (cirrhosis) according to histopathological findings. Data were extracted to calculate the pooled sensitivity, specificity, positive and negative likelihood ratios, and diagnostic odds ratio, as well as the area under the summary receiver operating characteristic curve (AUC) in each group.
RESULTS A total of 12 studies with 923 subjects were included in this meta-analysis with 5 studies (n = 465) for LF ≥ F1, 9 studies (n = 757) for LF ≥ F2, 4 studies (n = 413) for LF ≥ F3, and 6 studies (n = 562) for LF = F4. The pooled sensitivity and specificity were estimated to be 0.78 (95% confidence interval: 0.73-0.82) and 0.81 (0.74-0.86) for LF ≥ F1 detection with IVIM; 0.82 (0.79-0.86) and 0.80 (0.75-0.84) for staging F2 fibrosis; 0.85 (0.79-0.90) and 0.83 (0.77-0.87) for staging F3 fibrosis, and 0.90 (0.84-0.94) and 0.75 (0.70-0.79) for detecting F4 cirrhosis, respectively. The AUCs for LF ≥ F1, F2, F3, F4 detection were 0.862 (0.811-0.914), 0.883 (0.856-0.909), 0.886 (0.865-0.907), and 0.899 (0.866-0.932), respectively. Moderate to substantial heterogeneity was observed with inconsistency index (I2) ranging from 0% to 77.9%. No publication bias was detected.
CONCLUSION IVIM is a noninvasive tool with good diagnostic performance in detecting and staging LF. Optimized and standardized IVIM protocols are needed to further improve its diagnostic accuracy in clinical practice.
Collapse
Affiliation(s)
- Zheng Ye
- West China School of Medicine, Sichuan University, Chengdu 610041, Sichuan Province, China
| | - Yi Wei
- West China School of Medicine, Sichuan University, Chengdu 610041, Sichuan Province, China
| | - Jie Chen
- West China School of Medicine, Sichuan University, Chengdu 610041, Sichuan Province, China
| | - Shan Yao
- West China School of Medicine, Sichuan University, Chengdu 610041, Sichuan Province, China
| | - Bin Song
- Department of Radiology, West China Hospital, Sichuan University, Chengdu 610041, Sichuan Province, China
| |
Collapse
|
24
|
Peng J, Zheng J, Yang C, Wang R, Zhou Y, Tao YY, Gong XQ, Wang WC, Zhang XM, Yang L. Intravoxel incoherent motion diffusion-weighted imaging to differentiate hepatocellular carcinoma from intrahepatic cholangiocarcinoma. Sci Rep 2020. [DOI: doi.org/10.1038/s41598-020-64804-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022] Open
Abstract
AbstractThe present study aimed to explore the value of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) in differentiating hepatocellular carcinoma (HCC) from intrahepatic cholangiocarcinoma (ICC). This study included 65 patients with malignant hepatic nodules (55 with HCC, 10 with ICC), and 17 control patients with normal livers. All patients underwent IVIM-DWI scans on a 3.0 T magnetic resonance imaging (MRI) scanner. The standard apparent diffusion coefficient (ADC), pure diffusion coefficient (Dslow), pseudo-diffusion coefficient (Dfast), and perfusion fraction (f) were obtained. Differences in the parameters among the groups were analysed using one-way ANOVA, with p < 0.05 indicating statistical significance. Receiver operating characteristic (ROC) curve analysis was used to compare the efficacy of each parameter in differentiating HCC from ICC. ADC, Dslow, Dfast, f significantly differed among the three groups. ADC and Dslow were significantly lower in the HCC group than in the ICC group, while Dfast was significantly higher in the HCC group than in the ICC group; f did not significantly differ between the HCC and ICC groups. When the cut-off values of ADC, Dslow, and Dfast were 1.27 × 10−3 mm2/s, 0.81 × 10−3 mm2/s, and 26.04 × 10−3 mm2/s, respectively, their diagnostic sensitivities for differentiating HCC from ICC were 98.18%, 58.18%, and 94.55%, their diagnostic specificities were 50.00%, 80.00%, and 80.00%, and their areas under the ROC curve (AUCs) were 0.687, 0.721, and 0.896, respectively. Dfast displayed the largest AUC value. IVIM-DWI can be used to differentiate HCC from ICC.
Collapse
|
25
|
Intravoxel incoherent motion diffusion-weighted imaging to differentiate hepatocellular carcinoma from intrahepatic cholangiocarcinoma. Sci Rep 2020; 10:7717. [PMID: 32382050 PMCID: PMC7206040 DOI: 10.1038/s41598-020-64804-9] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2019] [Accepted: 04/20/2020] [Indexed: 02/08/2023] Open
Abstract
The present study aimed to explore the value of intravoxel incoherent motion diffusion-weighted imaging (IVIM-DWI) in differentiating hepatocellular carcinoma (HCC) from intrahepatic cholangiocarcinoma (ICC). This study included 65 patients with malignant hepatic nodules (55 with HCC, 10 with ICC), and 17 control patients with normal livers. All patients underwent IVIM-DWI scans on a 3.0 T magnetic resonance imaging (MRI) scanner. The standard apparent diffusion coefficient (ADC), pure diffusion coefficient (Dslow), pseudo-diffusion coefficient (Dfast), and perfusion fraction (f) were obtained. Differences in the parameters among the groups were analysed using one-way ANOVA, with p < 0.05 indicating statistical significance. Receiver operating characteristic (ROC) curve analysis was used to compare the efficacy of each parameter in differentiating HCC from ICC. ADC, Dslow, Dfast, f significantly differed among the three groups. ADC and Dslow were significantly lower in the HCC group than in the ICC group, while Dfast was significantly higher in the HCC group than in the ICC group; f did not significantly differ between the HCC and ICC groups. When the cut-off values of ADC, Dslow, and Dfast were 1.27 × 10−3 mm2/s, 0.81 × 10−3 mm2/s, and 26.04 × 10−3 mm2/s, respectively, their diagnostic sensitivities for differentiating HCC from ICC were 98.18%, 58.18%, and 94.55%, their diagnostic specificities were 50.00%, 80.00%, and 80.00%, and their areas under the ROC curve (AUCs) were 0.687, 0.721, and 0.896, respectively. Dfast displayed the largest AUC value. IVIM-DWI can be used to differentiate HCC from ICC.
Collapse
|
26
|
Diffusion kurtosis imaging in liver: a preliminary reproducibility study in healthy volunteers. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2020; 33:877-883. [PMID: 32377906 DOI: 10.1007/s10334-020-00846-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Revised: 04/07/2020] [Accepted: 04/16/2020] [Indexed: 12/29/2022]
Abstract
OBJECTIVES To systematically test the reproducibility of DKI technique in normal liver and report a complete set of DKI measurement data. MATERIALS AND METHODS Thirty-two healthy volunteers were examined with liver DKI twice on the GE 3.0 T MRI scanner and reviewed by three professional experts. DKI-derived parameters fractional anisotropy of kurtosis (FAk), mean diffusivity (Md), axial diffusivity (Da), radial diffusivity (Dr), mean kurtosis (Mk), axial kurtosis (Ka), and radial kurtosis (Kr) in eight segments divided by Couinaud octagonal method were collected. Inter-class correlation coefficient (ICC) was used to assess the agreement between three experts. For each expert, the reproducibility of twice scans was evaluated by Bland-Altman method. Multivariate analysis of variance was to explore the regional distribution characteristics of DKI-derived parameters, and showed with box-plot graph. RESULTS Using ICC analysis, except for FAk (ICC 0.312, 0.307), other DKI metric values showed high reproducibility (0.716 < ICC < 0.907) between three experts for each of two DKI measurements. With Bland-Altman method, liver segment 5 (S5) showed the best reproducibility between two DKI measurement, and the reproducibility of segment 4 (S4) was the worst. The reproducibility of the right lobe was significantly higher than the left lobe. The values of diffusion metrics (Md, Da, and Dr) and kurtosis metrics (Mk, Ka, and Kr) existed significantly difference between the right and left hepatic lobes. CONCLUSION DKI has shown excellent reproducibility in liver imaging. The range of values for multiple DKI parameters, derived from the normal liver, was reported, and may provide data reference for further clinical DKI applications. Additionally, DKI technique is a non-invasive method to reflect the perfusion or structural differences between the left and right hepatic lobes from the molecular level.
Collapse
|
27
|
Jang M, Jin S, Kang M, Han S, Cho H. Pattern recognition analysis of directional intravoxel incoherent motion MRI in ischemic rodent brains. NMR IN BIOMEDICINE 2020; 33:e4268. [PMID: 32067300 DOI: 10.1002/nbm.4268] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/23/2019] [Revised: 01/14/2020] [Accepted: 01/17/2020] [Indexed: 06/10/2023]
Abstract
This study aimed to demonstrate a reliable automatic segmentation method for independently separating reduced diffusion and decreased perfusion areas in ischemic stroke brains using constrained nonnegative matrix factorization (cNMF) pattern recognition in directional intravoxel incoherent motion MRI (IVIM-MRI). First, the feasibility of cNMF-based segmentation of IVIM signals was investigated in both simulations and in vivo experiments. The cNMF analysis was independently performed for S0 -normalized and scaled (by the difference between the maximum and minimum) IVIM signals, respectively. Segmentations of reduced diffusion (from S0 -normalized IVIM signals) and decreased perfusion (from scaled IVIM signals) areas were performed using the corresponding cNMF pattern weight maps. Second, Monte Carlo simulations were performed for directional IVIM signals to investigate the relationship between the degree of vessel alignment and the direction of the diffusion gradient. Third, directional IVIM-MRI experiments (x, y and z diffusion-gradient directions, 20 b values at 7 T) were performed for normal (n = 4), sacrificed (n = 1, no flow) and ischemic stroke models (n = 4, locally reduced flow). The results showed that automatic segmentation of the hypoperfused lesion using cNMF analysis was more accurate than segmentation using the conventional double-exponential fitting. Consistent with the simulation, the double-exponential pattern of the IVIM signals was particularly strong in white matter and ventricle regions when the directional flows were aligned with the applied diffusion-gradient directions. cNMF analysis of directional IVIM signals allowed robust automated segmentation of white matter, ventricle, vascular and hypoperfused regions in the ischemic brain. In conclusion, directional IVIM signals were simultaneously sensitive to diffusion and aligned flow and were particularly useful for automatically segmenting ischemic lesions via cNMF-based pattern recognition.
Collapse
Affiliation(s)
- MinJung Jang
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
| | - Seokha Jin
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
| | - MungSoo Kang
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
| | - SoHyun Han
- Center for Neuroscience Imaging Research, Institute of Basic Science (IBS), Suwon, South Korea
| | - HyungJoon Cho
- Department of Biomedical Engineering, Ulsan National Institute of Science and Technology, Ulsan, South Korea
| |
Collapse
|
28
|
Doudou NR, Liu Y, Kampo S, Zhang K, Dai Y, Wang S. Optimization of intravoxel incoherent motion (IVIM): variability of parameters measurements using a reduced distribution of b values for breast tumors analysis. MAGMA (NEW YORK, N.Y.) 2020; 33:273-281. [PMID: 31571014 DOI: 10.1007/s10334-019-00779-7] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/14/2019] [Revised: 09/13/2019] [Accepted: 09/17/2019] [Indexed: 06/10/2023]
Abstract
OBJECTIVES This study aimed to examine the variability of intravoxel incoherent motion measurements acquired from reduced distributions of b values for breast tumors analysis. MATERIALS AND METHODS The investigations were carried out on twenty-four patients with diagnosed breast tumors. A conventional unenhanced MRI and various IVIM series preset with different distributions of b values (0-1000 s/mm2) were performed. We assessed the variability in Dslow, Dfast, and PF measurements for different distributions of 9 to 4 b values compared with the IVIM metrics for 10 b values using Wilcoxon-Signed rank test. The data was statistically significant at P < 0.05. RESULTS The results showed no significant variation in the estimations of IVIM parameters in patients. However, the measurements acquired with the combination of 5 b values Showed some variation in Dfast (P = 0.028) compared with 10 b values. The data showed high wCVs in the measurements acquired using the reduced set of 6 b values for Dslow and PF and with the combination of 7 b values for Dfast. There were inconsistencies noticed in the measurements acquired from malignant tumors using reduced distributions of b values (9 b values-4 b values). However, the set of 4 b values displayed the lowest wCVs for both benign and malignant datasets. We also observed unsystematic correlations among different combinations of b values in the categories of IVIM parameters. CONCLUSION There was no relevant variation in the parameters measurements irrespective of the number of b values used. Reduced distributions of b values may find use in estimations of IVIM parameters for breast lesions analysis.
Collapse
Affiliation(s)
- Natacha Raissa Doudou
- Department of Radiology, Dalian Medical University, Dalian, China
- Department of Radiology, The Second Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Yajie Liu
- Department of Radiology, The Second Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Sylvanus Kampo
- Department of Anesthesiology, Dalian Medical University, Dalian, China
| | - Kai Zhang
- Department of Radiology, The Second Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Yue Dai
- Department of Radiology, The Second Affiliated Hospital of Dalian Medical University, Dalian, China
| | - Shaowu Wang
- Department of Radiology, Dalian Medical University, Dalian, China.
- Department of Radiology, The Second Affiliated Hospital of Dalian Medical University, Dalian, China.
| |
Collapse
|
29
|
Gurney‐Champion OJ, Rauh SS, Harrington K, Oelfke U, Laun FB, Wetscherek A. Optimal acquisition scheme for flow-compensated intravoxel incoherent motion diffusion-weighted imaging in the abdomen: An accurate and precise clinically feasible protocol. Magn Reson Med 2020; 83:1003-1015. [PMID: 31566262 PMCID: PMC6899942 DOI: 10.1002/mrm.27990] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Revised: 08/14/2019] [Accepted: 08/17/2019] [Indexed: 12/16/2022]
Abstract
PURPOSE Flow-compensated (FC) diffusion-weighted MRI (DWI) for intravoxel-incoherent motion (IVIM) modeling allows for a more detailed description of tissue microvasculature than conventional IVIM. The long acquisition time of current FC-IVIM protocols, however, has prohibited clinical application. Therefore, we developed an optimized abdominal FC-IVIM acquisition with a clinically feasible scan time. METHODS Precision and accuracy of the FC-IVIM parameters were assessed by fitting the FC-IVIM model to signal decay curves, simulated for different acquisition schemes. Diffusion-weighted acquisitions were added subsequently to the protocol, where we chose the combination of b-value, diffusion time and gradient profile (FC or bipolar) that resulted in the largest improvement to its accuracy and precision. The resulting two optimized FC-IVIM protocols with 25 and 50 acquisitions (FC-IVIMopt25 and FC-IVIMopt50 ), together with a complementary acquisition consisting of 50 diffusion-weighting (FC-IVIMcomp ), were acquired in repeated abdominal free-breathing FC-IVIM imaging of seven healthy volunteers. Intersession and intrasession within-subject coefficient of variation of the FC-IVIM parameters were compared for the liver, spleen, and kidneys. RESULTS Simulations showed that the performance of FC-IVIM improved in tissue with larger perfusion fraction and signal-to-noise ratio. The scan time of the FC-IVIMopt25 and FC-IVIMopt50 protocols were 8 and 16 min. The best in vivo performance was seen in FC-IVIMopt50 . The intersession within-subject coefficients of variation of FC-IVIMopt50 were 11.6%, 16.3%, 65.5%, and 36.0% for FC-IVIM model parameters diffusivity, perfusion fraction, characteristic time and blood flow velocity, respectively. CONCLUSIONS We have optimized the FC-IVIM protocol, allowing for clinically feasible scan times (8-16 min).
Collapse
Affiliation(s)
- Oliver J. Gurney‐Champion
- Joint Department of PhysicsThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Susanne S. Rauh
- Joint Department of PhysicsThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
- Institute of RadiologyUniversity Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU)ErlangenGermany
| | - Kevin Harrington
- Targeted Therapy teamThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Uwe Oelfke
- Joint Department of PhysicsThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| | - Frederik B. Laun
- Institute of RadiologyUniversity Hospital Erlangen, Friedrich‐Alexander‐Universität Erlangen‐Nürnberg (FAU)ErlangenGermany
| | - Andreas Wetscherek
- Joint Department of PhysicsThe Institute of Cancer Research and The Royal Marsden NHS Foundation TrustLondonUnited Kingdom
| |
Collapse
|
30
|
Hu YC, Yan LF, Han Y, Duan SJ, Sun Q, Li GF, Wang W, Wei XC, Zheng DD, Cui GB. Can the low and high b-value distribution influence the pseudodiffusion parameter derived from IVIM DWI in normal brain? BMC Med Imaging 2020; 20:14. [PMID: 32041549 PMCID: PMC7011602 DOI: 10.1186/s12880-020-0419-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/11/2019] [Accepted: 01/30/2020] [Indexed: 12/28/2022] Open
Abstract
Background Our study aims to reveal whether the low b-values distribution, high b-values upper limit, and the number of excitation (NEX) influence the accuracy of the intravoxel incoherent motion (IVIM) parameter derived from multi-b-value diffusion-weighted imaging (DWI) in the brain. Methods This prospective study was approved by the local Ethics Committee and informed consent was obtained from each participant. The five consecutive multi-b DWI with different b-value protocols (0–3500 s/mm2) were performed in 22 male healthy volunteers on a 3.0-T MRI system. The IVIM parameters from normal white matter (WM) and gray matter (GM) including slow diffusion coefficient (D), fast perfusion coefficient (D*) and perfusion fraction (f) were compared for differences among defined groups with different IVIM protocols by one-way ANOVA. Results The D* and f value of WM or GM in groups with less low b-values distribution (less than or equal to 5 b-values) were significantly lower than ones in any other group with more low b-values distribution (all P < 0.05), but no significant differences among groups with more low b-values distribution (P > 0.05). In addition, no significant differences in the D, D* and f value of WM or GM were found between group with one and more NEX of low b-values distribution (all P > 0.05). IVIM parameters in normal WM and GM strongly depended on the choice of the high b-value upper limit. Conclusions Metrics of IVIM parameters can be affected by low and high b value distribution. Eight low b-values distribution with high b-value upper limit of 800–1000 s/mm2 may be the relatively proper set when performing brain IVIM studies.
Collapse
Affiliation(s)
- Yu-Chuan Hu
- Department of Radiology and Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Air Force Medical University (Fourth Military Medical University), Xi'an, 710038, Shaanxi, People's Republic of China
| | - Lin-Feng Yan
- Department of Radiology and Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Air Force Medical University (Fourth Military Medical University), Xi'an, 710038, Shaanxi, People's Republic of China
| | - Yu Han
- Department of Radiology and Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Air Force Medical University (Fourth Military Medical University), Xi'an, 710038, Shaanxi, People's Republic of China
| | - Shi-Jun Duan
- Department of Radiology and Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Air Force Medical University (Fourth Military Medical University), Xi'an, 710038, Shaanxi, People's Republic of China
| | - Qian Sun
- Department of Radiology and Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Air Force Medical University (Fourth Military Medical University), Xi'an, 710038, Shaanxi, People's Republic of China
| | - Gang-Feng Li
- Department of Radiology and Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Air Force Medical University (Fourth Military Medical University), Xi'an, 710038, Shaanxi, People's Republic of China
| | - Wen Wang
- Department of Radiology and Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Air Force Medical University (Fourth Military Medical University), Xi'an, 710038, Shaanxi, People's Republic of China
| | - Xiao-Cheng Wei
- MR Research China, GE Healthcare China, Beijing, 100176, China
| | - Dan-Dan Zheng
- MR Research China, GE Healthcare China, Beijing, 100176, China
| | - Guang-Bin Cui
- Department of Radiology and Functional and Molecular Imaging Key Lab of Shaanxi Province, Tangdu Hospital, Air Force Medical University (Fourth Military Medical University), Xi'an, 710038, Shaanxi, People's Republic of China.
| |
Collapse
|
31
|
Paudyal R, Konar AS, Obuchowski NA, Hatzoglou V, Chenevert TL, Malyarenko DI, Swanson SD, LoCastro E, Jambawalikar S, Liu MZ, Schwartz LH, Tuttle RM, Lee N, Shukla-Dave A. Repeatability of Quantitative Diffusion-Weighted Imaging Metrics in Phantoms, Head-and-Neck and Thyroid Cancers: Preliminary Findings. ACTA ACUST UNITED AC 2020; 5:15-25. [PMID: 30854438 PMCID: PMC6403035 DOI: 10.18383/j.tom.2018.00044] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
The aim of this study was to establish the repeatability measures of quantitative Gaussian and non-Gaussian diffusion metrics using diffusion-weighted imaging (DWI) data from phantoms and patients with head-and-neck and papillary thyroid cancers. The Quantitative Imaging Biomarker Alliance (QIBA) DWI phantom and a novel isotropic diffusion kurtosis imaging phantom were scanned at 3 different sites, on 1.5T and 3T magnetic resonance imaging systems, using standardized multiple b-value DWI acquisition protocol. In the clinical component of this study, a total of 60 multiple b-value DWI data sets were analyzed for test–retest, obtained from 14 patients (9 head-and-neck squamous cell carcinoma and 5 papillary thyroid cancers). Repeatability of quantitative DWI measurements was assessed by within-subject coefficient of variation (wCV%) and Bland–Altman analysis. In isotropic diffusion kurtosis imaging phantom vial with 2% ceteryl alcohol and behentrimonium chloride solution, the mean apparent diffusion (Dapp × 10−3 mm2/s) and kurtosis (Kapp, unitless) coefficient values were 1.02 and 1.68 respectively, capturing in vivo tumor cellularity and tissue microstructure. For the same vial, Dapp and Kapp mean wCVs (%) were ≤1.41% and ≤0.43% for 1.5T and 3T across 3 sites. For pretreatment head-and-neck squamous cell carcinoma, apparent diffusion coefficient, D, D*, K, and f mean wCVs (%) were 2.38%, 3.55%, 3.88%, 8.0%, and 9.92%, respectively; wCVs exhibited a higher trend for papillary thyroid cancers. Knowledge of technical precision and bias of quantitative imaging metrics enables investigators to properly design and power clinical trials and better discern between measurement variability versus biological change.
Collapse
Affiliation(s)
- Ramesh Paudyal
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
| | | | - Nancy A Obuchowski
- Department of Quantitative Health Sciences, Cleveland Clinic Foundation, Cleveland, OH
| | - Vaios Hatzoglou
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY
| | | | | | - Scott D Swanson
- Department of Radiology, University of Michigan, Ann Arbor, MI
| | - Eve LoCastro
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Sachin Jambawalikar
- Department of Radiology, Columbia University Irving Medical Center, and New York Presbyterian Hospital, New York, NY
| | - Michael Z Liu
- Department of Radiology, Columbia University Irving Medical Center, and New York Presbyterian Hospital, New York, NY
| | - Lawrence H Schwartz
- Department of Radiology, Columbia University Irving Medical Center, and New York Presbyterian Hospital, New York, NY
| | | | - Nancy Lee
- Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, NY
| | - Amita Shukla-Dave
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, NY.,Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, NY
| |
Collapse
|
32
|
Chen F, Chen YL, Chen TW, Li R, Pu Y, Zhang XM, Li HJ, Tang S, Cao JM, Yang JQ. Liver lobe based intravoxel incoherent motion diffusion weighted imaging in hepatitis B related cirrhosis: Association with child-pugh class and esophageal and gastric fundic varices. Medicine (Baltimore) 2020; 99:e18671. [PMID: 31914057 PMCID: PMC6959964 DOI: 10.1097/md.0000000000018671] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/26/2022] Open
Abstract
Liver cirrhosis is a common chronic progressive liver disease in clinical practice, and intravoxel incoherent motion (IVIM) is a promising magnetic resonance method to assess liver cirrhosis, so our purpose was to investigate association of liver-lobe-based IVIM-derived parameters with hepatitis-B-related cirrhosis and its severity, and esophageal and gastric fundic varices. Seventy-four patients with hepatitis-B-related cirrhotic and 25 healthy volunteers were enrolled and underwent upper abdominal IVIM diffusion-weighted imaging with b-values of 0, 20, 50, 80, 100, 200, 400, 600, and 800 s/mm. IVIM-derived parameters (D, pure molecular diffusion; D, pseudo diffusion; and f, perfusion fraction) of left lateral lobe (LLL), left medial lobe (LML), right lobe (RL), and caudate lobe (CL) were assessed statistically to show their associations with cirrhosis and its severity, and esophageal and gastric fundic varices. In this research, we found that D, D, and f values of LLL, LML, RL, and CL were lower in cirrhotic liver than in normal liver (all P-values <.05). D, D, and f values of LLL, LML, RL, and CL were inversely correlated with Child-Pugh class of cirrhosis (r = -0.236 to -0.606, all P-values <.05). D of each liver lobe, D of LLL and CL, and f of LLL, LML, and CL in patients with esophageal and gastric fundic varices were lower than without the varices (all P-values <.05). D values of RL and CL could best identify cirrhosis, and identify esophageal and gastric fundic varices with areas under receiver-operating characteristic curve of 0.857 and 0.746, respectively. We concluded that liver-lobe-based IVIM-derived parameters can be associated with cirrhosis, and esophageal and gastric fundic varices.
Collapse
Affiliation(s)
- Fan Chen
- Sichuan Key Laboratory of Medical Imaging, and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, Sichuan
- Department of Radiology, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing
| | - Yan-li Chen
- Sichuan Key Laboratory of Medical Imaging, and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, Sichuan
- Department of Radiology, Southwest Hospital, Army Medical University (Third Military Medical University), Chongqing
| | - Tian-wu Chen
- Sichuan Key Laboratory of Medical Imaging, and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, Sichuan
| | - Rui Li
- Sichuan Key Laboratory of Medical Imaging, and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, Sichuan
| | - Yu Pu
- Sichuan Key Laboratory of Medical Imaging, and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, Sichuan
| | - Xiao-ming Zhang
- Sichuan Key Laboratory of Medical Imaging, and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, Sichuan
| | - Hong-jun Li
- Department of Radiology, Beijing YouAn Hospital, Capital Medical University, Beijing, China
| | - Sun Tang
- Sichuan Key Laboratory of Medical Imaging, and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, Sichuan
| | - Jin-ming Cao
- Sichuan Key Laboratory of Medical Imaging, and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, Sichuan
| | - Jian-qiong Yang
- Sichuan Key Laboratory of Medical Imaging, and Department of Radiology, Affiliated Hospital of North Sichuan Medical College, Nanchong, Sichuan
| |
Collapse
|
33
|
Öz A, Server S, Koyuncu Sökmen B, Namal E, İnan N, Balcı NC. Intravoxel Incoherent Motion of Colon Cancer Liver Metastases for the Assessment of Response to Antiangiogenic Treatment: Results from a Pilot Study. Med Princ Pract 2020; 29:429-435. [PMID: 31914438 PMCID: PMC7511688 DOI: 10.1159/000505814] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/22/2019] [Accepted: 01/08/2020] [Indexed: 01/21/2023] Open
Abstract
OBJECTIVE This study was aimed at evaluating the intravoxel incoherent motion (IVIM) parameter alterations of liver metastases of colorectal carcinoma (CRC) during antiangiogenic bevacizumab combination therapy. METHODS Twenty-five patients with CRC liver metastases treated with bevacizumab in combination with FOLFOX-or-FOLFIRI protocols were enrolled in the study. MRI was performed using a 1.5-tesla scanner pre-treatment (PT) and at 3, 6, and 9 months of therapy. Routine abdominal MRI sequences and an IVIM-DWI (diffusion-weighted imaging) sequence were obtained. The IVIM-DWI sequence was executed with 16 b-values varying from 0 to 1,400 s/mm2. The mean values of apparent diffusion coefficient (ADC), true diffusion (D), pseudodiffusion (D*), and perfusion fraction (f) of each metastasis were obtained for all b-values, and the time-related changes were recorded to analyze the chronologic responses to antiangiogenic therapy. The RECIST 1.1 criteria were used for the evaluation of treatment response. RESULTS The diameters of the metastases diminished significantly at 9 months when compared with PT (p = 0.03). The D (p = 0.10) and ADC (p = 0.21) values of the metastases increased at 9 months of therapy. D* was the highest at 3 months (p =0.24); it decreased at 6 (p =0.97) and 9 months (p =0.87) of therapy. The f value had peaked at 3 months (p =0.51) and started to decrease thereafter. At 6 months, f decreased to the lowest values (p =0.12). CONCLUSION IVIM parameters, particularly the perfusion fraction, may quantitatively reflect the response to antiangiogenic treatment. The antiangiogenic response manifests after 3 months of therapy before the RECIST-related response.
Collapse
Affiliation(s)
- Ayşegül Öz
- Department of Radiology, Faculty of Medicine, Istanbul Bilim University, Istanbul, Turkey,
| | - Sadık Server
- Department of Radiology, Faculty of Medicine, Istanbul Bilim University, Istanbul, Turkey
| | - Bedriye Koyuncu Sökmen
- Department of Radiology, Faculty of Medicine, Istanbul Bilim University, Istanbul, Turkey
| | - Esat Namal
- Department of Medical Oncology, Faculty of Medicine, Istanbul Bilim University, Istanbul, Turkey
| | - Nagihan İnan
- Department of Radiology, Faculty of Medicine, Istanbul Bilim University, Istanbul, Turkey
| | - Numan Cem Balcı
- Department of Radiology, Cleveland Clinic, Lerner School of Medicine, Abu Dhabi, United Arab Emirates
| |
Collapse
|
34
|
Chabert S, Verdu J, Huerta G, Montalba C, Cox P, Riveros R, Uribe S, Salas R, Veloz A. Impact of b-Value Sampling Scheme on Brain IVIM Parameter Estimation in Healthy Subjects. Magn Reson Med Sci 2019; 19:216-226. [PMID: 31611542 PMCID: PMC7553810 DOI: 10.2463/mrms.mp.2019-0061] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/23/2022] Open
Abstract
Purpose: Intravoxel incoherent motion (IVIM) analysis has attracted the interest of the clinical community due to its close relationship with microperfusion. Nevertheless, there is no clear reference protocol for its implementation; one of the questions being which b-value distribution to use. This study aimed to stress the importance of the sampling scheme and to show that an optimized b-value distribution decreases the variance associated with IVIM parameters in the brain with respect to a regular distribution in healthy volunteers. Methods: Ten volunteers were included in this study; images were acquired on a 1.5T MR scanner. Two distributions of 16 b-values were used: one considered ‘regular’ due to its close association with that used in other studies, and the other considered ‘optimized’ according to previous studies. IVIM parameters were adjusted according to the bi-exponential model, using two-step method. Analysis was undertaken in ROI defined using in the Automated Anatomical Labeling atlas, and parameters distributions were compared in a total of 832 ROI. Results: Maps with fewer speckles were obtained with the ‘optimized’ distribution. Coefficients of variation did not change significantly for the estimation of the diffusion coefficient D but decreased by approximately 39% for the pseudo-diffusion coefficient estimation and by 21% for the perfusion fraction. Distributions of adjusted parameters were found significantly different in 50% of the cases for the perfusion fraction, in 80% of the cases for the pseudo-diffusion coefficient and 17% of the cases for the diffusion coefficient. Observations across brain areas show that the range of average values for IVIM parameters is smaller in the ‘optimized’ case. Conclusion: Using an optimized distribution, data are sampled in a way that the IVIM signal decay is better described and less variance is obtained in the fitted parameters. The increased precision gained could help to detect small variations in IVIM parameters.
Collapse
Affiliation(s)
- Stéren Chabert
- CINGS Centro de Investigación y Desarrollo de Ingeniería para la Salud, Universidad de Valparaíso.,Escuela de Ingenieria Civil Biomedica, Universidad de Valparaíso.,Millennium Nucleus for Cardiovascular Magnetic Resonance
| | - Jorge Verdu
- Escuela de Ingenieria Civil Biomedica, Universidad de Valparaíso.,Universidad Politécnica de Valencia
| | - Gamaliel Huerta
- Escuela de Ingenieria Civil Biomedica, Universidad de Valparaíso
| | - Cristian Montalba
- Center for Biomedical Imaging, Pontificia Universidad Católica de Chile
| | - Pablo Cox
- Servicio de Imagenología, Hospital Carlos van Buren
| | - Rodrigo Riveros
- Servicio de Imagenología, Hospital Carlos van Buren.,Facultad de Medicina, Universidad de Valparaíso
| | - Sergio Uribe
- Millennium Nucleus for Cardiovascular Magnetic Resonance.,Center for Biomedical Imaging, Pontificia Universidad Católica de Chile.,Radiology Department, Pontificia Universidad Católica de Chile
| | - Rodrigo Salas
- CINGS Centro de Investigación y Desarrollo de Ingeniería para la Salud, Universidad de Valparaíso.,Escuela de Ingenieria Civil Biomedica, Universidad de Valparaíso
| | - Alejandro Veloz
- CINGS Centro de Investigación y Desarrollo de Ingeniería para la Salud, Universidad de Valparaíso.,Escuela de Ingenieria Civil Biomedica, Universidad de Valparaíso
| |
Collapse
|
35
|
Effect of combination and number of b values in IVIM analysis with post-processing methodology: simulation and clinical study. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2019; 32:519-527. [DOI: 10.1007/s10334-019-00764-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/08/2019] [Revised: 05/10/2019] [Accepted: 06/04/2019] [Indexed: 01/24/2023]
|
36
|
Jalnefjord O, Montelius M, Starck G, Ljungberg M. Optimization of b-value schemes for estimation of the diffusion coefficient and the perfusion fraction with segmented intravoxel incoherent motion model fitting. Magn Reson Med 2019; 82:1541-1552. [PMID: 31148264 PMCID: PMC6772171 DOI: 10.1002/mrm.27826] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2018] [Revised: 05/03/2019] [Accepted: 05/05/2019] [Indexed: 01/01/2023]
Abstract
PURPOSE Intravoxel incoherent motion (IVIM) modeling for estimation of the diffusion coefficient (D) and perfusion fraction (f) is increasingly popular, but no consensus on standard protocols exists. This study provides a framework for optimization of b-value schemes for reduced estimation uncertainty of D and f from segmented model fitting. THEORY Analytical expressions for uncertainties of D and f from segmented model fitting were derived as Cramer-Rao lower bounds (CRLBs). METHODS Optimized b-value schemes were obtained for 3 to 12 acquisitions and in the limit of infinitely many acquisitions through constrained minimization of the CRLBs, with b-values constrained to be 0 or 200 to 800 s/mm2 . The optimized b-value scheme with eight acquisitions was compared with b-values linearly distributed in the allowed range using simulations and in vivo liver data from seven healthy volunteers. RESULTS All optimized b-value schemes contained exactly three unique b-values regardless of the total number of acquisitions (0, 200, and 800 s/mm2 ) with repeated acquisitions distributed approximately as 1:2:2. Compared with linearly distributed b-values, the variability of estimates of D and f was reduced by approximately 30% as seen both in simulations and in repeated in vivo measurements. CONCLUSION The uncertainty of IVIM D and f estimates can be reduced by the use of optimized b-value schemes.
Collapse
Affiliation(s)
- Oscar Jalnefjord
- Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Mikael Montelius
- Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden
| | - Göran Starck
- Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| | - Maria Ljungberg
- Department of Radiation Physics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden.,Department of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gothenburg, Sweden
| |
Collapse
|
37
|
Gurney-Champion OJ, Collins DJ, Wetscherek A, Rata M, Klaassen R, van Laarhoven HWM, Harrington KJ, Oelfke U, Orton MR. Principal component analysis fosr fast and model-free denoising of multi b-value diffusion-weighted MR images. Phys Med Biol 2019; 64:105015. [PMID: 30965296 PMCID: PMC7655121 DOI: 10.1088/1361-6560/ab1786] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2018] [Revised: 03/18/2019] [Accepted: 04/09/2019] [Indexed: 02/08/2023]
Abstract
Despite the utility of tumour characterisation using quantitative parameter maps from multi-b-value diffusion-weighted MRI (DWI), clinicians often prefer the use of the image with highest diffusion-weighting (b-value), for instance for defining regions of interest (ROIs). However, these images are typically degraded by noise, as they do not utilize the information from the full acquisition. We present a principal component analysis (PCA) approach for model-free denoising of DWI data. PCA-denoising was compared to synthetic MRI, where a diffusion model is fitted for each voxel and a denoised image at a given b-value is generated from the model fit. A quantitative comparison of systematic and random errors was performed on data simulated using several diffusion models (mono-exponential, bi-exponential, stretched-exponential and kurtosis). A qualitative visual comparison was also performed for in vivo images in six healthy volunteers and three pancreatic cancer patients. In simulations, the reduction in random errors from PCA-denoising was substantial (up to 55%) and similar to synthetic MRI (up to 53%). Model-based synthetic MRI denoising resulted in substantial (up to 29% of signal) systematic errors, whereas PCA-denoising was able to denoise without introducing systematic errors (less than 2%). In vivo, the signal-to-noise ratio (SNR) and sharpness of PCA-denoised images were superior to synthetic MRI, resulting in clearer tumour boundaries. In the presence of motion, PCA-denoising did not cause image blurring, unlike image averaging or synthetic MRI. Multi-b-value MRI can be denoised model-free with our PCA-denoising strategy that reduces noise to a level similar to synthetic MRI, but without introducing systematic errors associated with the synthetic MRI method.
Collapse
Affiliation(s)
- Oliver J Gurney-Champion
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom
| | - David J Collins
- Cancer Research UK Cancer Imaging Centre,
The Institute of Cancer Research and The
Royal Marsden NHS Foundation Trust, London, United
Kingdom
| | - Andreas Wetscherek
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom
| | - Mihaela Rata
- Cancer Research UK Cancer Imaging Centre,
The Institute of Cancer Research and The
Royal Marsden NHS Foundation Trust, London, United
Kingdom
| | - Remy Klaassen
- Department of Medical Oncology, Cancer Center
Amsterdam, Amsterdam UMC, University of
Amsterdam, Amsterdam, The Netherlands
| | - Hanneke W M van Laarhoven
- Department of Medical Oncology, Cancer Center
Amsterdam, Amsterdam UMC, University of
Amsterdam, Amsterdam, The Netherlands
| | - Kevin J Harrington
- Targeted Therapy Team, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom
| | - Uwe Oelfke
- Joint Department of Physics, The Institute of Cancer Research and The Royal Marsden
NHS Foundation Trust, London, United
Kingdom
| | - Matthew R Orton
- Cancer Research UK Cancer Imaging Centre,
The Institute of Cancer Research and The
Royal Marsden NHS Foundation Trust, London, United
Kingdom
| |
Collapse
|
38
|
Chiang CW, Lin SY, Cho KH, Wu KJ, Wang Y, Kuo LW. Effects of signal averaging, gradient encoding scheme, and spatial resolution on diffusion kurtosis imaging: An empirical study using 7T MRI. J Magn Reson Imaging 2019; 50:1593-1603. [PMID: 30990956 DOI: 10.1002/jmri.26755] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2019] [Accepted: 04/04/2019] [Indexed: 11/11/2022] Open
Abstract
BACKGROUND Although diffusion gradient directions and b-values have been optimized for diffusion kurtosis imaging (DKI), little is known about the effect of signal averaging on DKI reliability. PURPOSE To evaluate how signal averaging influences the reliability of DKI indices using two gradient encoding schemes with three spatial resolutions. STUDY TYPE Prospective. ANIMAL MODEL Fifteen naïve Sprague-Dawley rats. FIELD STRENGTH/SEQUENCE DKI was performed at 7T using two schemes (30 directions with three b-values [30d-3b] and six directions with 15 b-values [6d-15b]), three resolutions, and eight repetitions. ASSESSMENT DKI reliability was assessed using voxelwise relative error (σ) and test-retest error of fractional anisotropy (FA), mean diffusivity (MD), and mean kurtosis (MK) within gray matter (GM) and white matter (WM). The number of excitations (NEX) was optimized by considering DKI reliability. The influence of the partial volume effect (PVE) was also assessed. STATISTICAL TEST One-way analysis of variance. RESULTS The 30d-3b scheme, compared with the 6d-15b scheme, exhibited apparently smaller σFA and σMK (eg, at NEX 1, in GM, for three resolutions, σFA : 19.9-38.2% vs. 34.2-61.4%, σMK : 6.9-11.4% vs. 14.1-15.4%) and similar σMD (all differences between two schemes <1.6%). The optimal NEX was determined as 2 for enabling a reliable measurement of DKI-derived indices. The PVE at the lowest resolution apparently increased σFA for both schemes (19.9% for 30d-3b and 34.2% for 6d-15b) and σMK for the 6d-15b scheme (14.7%) in GM, and exerted lower effects on MK values for the 30d-3b scheme (P > 0.05). DATA CONCLUSION A higher number of diffusion directions would benefit FA and MK estimation. A higher spatial resolution helps to reduce PVE. By using the 30d-3b scheme, MK is considered a robust index to reflect microstructural changes in GM and WM. We propose a systematic approach to determine the optimal DKI protocols for appropriate preclinical settings. LEVEL OF EVIDENCE 2 Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;50:1593-1603.
Collapse
Affiliation(s)
- Chia-Wen Chiang
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes (NHRI), Miaoli, Taiwan
| | - Shih-Yen Lin
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes (NHRI), Miaoli, Taiwan.,Department of Computer Science, National Chiao Tung University, Hsinchu, Taiwan
| | - Kuan-Hung Cho
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes (NHRI), Miaoli, Taiwan
| | - Kuo-Jen Wu
- Center for Neuropsychiatric Research, NHRI, Miaoli, Taiwan
| | - Yun Wang
- Center for Neuropsychiatric Research, NHRI, Miaoli, Taiwan
| | - Li-Wei Kuo
- Institute of Biomedical Engineering and Nanomedicine, National Health Research Institutes (NHRI), Miaoli, Taiwan.,Institute of Medical Device and Imaging, National Taiwan University College of Medicine, Taipei, Taiwan
| |
Collapse
|
39
|
Can IVIM help predict HCC recurrence after hepatectomy? Eur Radiol 2019; 29:5791-5803. [PMID: 30972544 DOI: 10.1007/s00330-019-06180-1] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2018] [Revised: 01/30/2019] [Accepted: 02/08/2019] [Indexed: 12/16/2022]
Abstract
PURPOSE To determine the diagnostic performance of intravoxel incoherent motion (IVIM) parameters to predict tumor recurrence after hepatectomy in patients with hepatitis B virus (HBV)-related hepatocellular carcinoma (HCC). MATERIALS AND METHODS One hundred and fifty-seven patients (mean age 52.54 ± 11.32 years, 87% male) with surgically and pathologically confirmed HCC were included. Regions of interests were drawn including the tumors by two independent radiologists. ADC and IVIM-derived parameters (true diffusion coefficient [D]; pseudodiffusion coefficient [D*]; pseudodiffusion fraction [f]) were obtained preoperatively. The Cox proportional hazards model was used to analyze the predictors associated with tumor recurrence after hepatectomy. RESULTS Forty-seven of 157 (29.9%) patients experienced tumor recurrence. The multivariate Cox proportional hazards model revealed that a D value < 0.985 × 10-3 mm2/s (hazard ratio (HR), 0.190; p = 0.023) was a risk factor for tumor recurrence. Additional risk factors included younger age (HR, 0.328; p = 0.034) and higher serum alpha-fetoprotein (AFP) level (HR, 2.079; p = 0.013). Further, receiver operating characteristic (ROC) analysis showed that the area under the curve (AUC) of the obtained Cox regression model improved from 0.68 for the combination of AFP and age alone to 0.724 for the combination of D value, AFP, and age. CONCLUSION The D value derived from the IVIM model is a potential biomarker for the preoperative prediction of recurrence after hepatectomy in patients with HCC. When combined with age and AFP levels, D can improve the predictive performance for tumor recurrence. KEY POINTS • The recurrence rate of HCC after hepatectomy was higher in patients with ADC, D, and f values that were lower than the optimal cutoff values. • The optimal cutoff values of ADC, D, D*, and f for predicting recurrence in HBV associated HCC were 0.858 × 10-3 mm2/s, 0.985 × 10-3 mm2/s, 12.5 × 10-3 mm2/s, and 23.4%, respectively. • The D value derived from IVIM diffusion-weighted imaging may be a useful biomarker for preoperative prediction of recurrence after hepatectomy in patients with HCC. When combined with age and AFP levels, D can improve the predictive performance for tumor recurrence.
Collapse
|
40
|
Zhang Y, Peña-Nogales Ó, Holmes JH, Hernando D. Motion-robust and blood-suppressed M1-optimized diffusion MR imaging of the liver. Magn Reson Med 2019; 82:302-311. [PMID: 30859628 DOI: 10.1002/mrm.27735] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2018] [Revised: 02/10/2019] [Accepted: 02/20/2019] [Indexed: 12/11/2022]
Abstract
PURPOSE To develop motion-robust, blood-suppressed diffusion-weighted imaging (DWI) of the liver with optimized diffusion encoding waveforms and evaluate the accuracy and reproducibility of quantitative apparent diffusion coefficient (ADC) measurements. METHODS A novel approach for the design of diffusion weighting waveforms, termed M1-optimized diffusion imaging (MODI), is proposed. MODI includes an echo time-optimized motion-robust diffusion weighting gradient waveform design, with a small nonzero first-moment motion sensitivity (M1) value to enable blood signal suppression. Experiments were performed in eight healthy volunteers and five patient volunteers. In each case, DW images and ADC maps were compared between acquisitions using standard monopolar waveforms, motion moment-nulled (M1-nulled and M1-M2-nulled) waveforms, and the proposed MODI approach. RESULTS Healthy volunteer experiments using MODI showed no significant ADC bias in the left lobe relative to the right lobe (p < .05) demonstrating robustness to cardiac motion, and no significant ADC bias with respect to monopolar-based ADC measured in the right lobe (p < .05), demonstrating blood signal suppression. In contrast, monopolar-based ADC showed significant bias in the left lobe relative to the right lobe (p < .01) due to its sensitivity to motion, and both M1-nulled and M1-M2-nulled-based ADC showed significant bias (p < .01) due to the lack of blood suppression. Preliminary patient results also suggest MODI may enable improved visualization and quantitative assessment of lesions throughout the entire liver. CONCLUSIONS This novel method for diffusion gradient waveform design enables DWI of the liver with high robustness to motion and suppression of blood signals, overcoming the limitations of conventional monopolar waveforms and moment-nulled waveforms, respectively.
Collapse
Affiliation(s)
- Yuxin Zhang
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin.,Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin
| | - Óscar Peña-Nogales
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin.,Laboratorio de Procesado de Imagen, Universidad de Valladolid, Valladolid, Spain
| | - James H Holmes
- Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin
| | - Diego Hernando
- Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin.,Department of Radiology, University of Wisconsin-Madison, Madison, Wisconsin
| |
Collapse
|
41
|
Wáng YXJ. Living tissue intravoxel incoherent motion (IVIM) diffusion MR analysis without b=0 image: an example for liver fibrosis evaluation. Quant Imaging Med Surg 2019; 9:127-133. [PMID: 30976535 PMCID: PMC6414775 DOI: 10.21037/qims.2019.01.07] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2019] [Accepted: 01/25/2019] [Indexed: 12/19/2022]
Affiliation(s)
- Yì Xiáng J Wáng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, Prince of Wales Hospital, Shatin, New Territories, Hong Kong, China
| |
Collapse
|
42
|
Lin CC, Ou HY, Chuang YH, Chiang HJ, Yu CC, Lazo M, Tsang LLC, Huang TL, Lin CC, Chen CL, Cheng YF. Diffusion-Weighted Magnetic Resonance Imaging in Liver Graft Rejection. Transplant Proc 2018; 50:2675-2678. [PMID: 30401375 DOI: 10.1016/j.transproceed.2018.04.018] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2018] [Revised: 03/22/2018] [Accepted: 04/06/2018] [Indexed: 01/24/2023]
Abstract
OBJECTIVE The purpose of this study is to evaluate the use of diffusion-weighted magnetic resonance imaging (DWMRI) in the assessment of graft rejection after liver transplantation (LT). METHODS From June 2017 to January 2018, 32 patients were included in the study with a mean age of 52.3 years. All patients underwent LT. The DWMRI was performed using the apparent diffusion coefficient map and measuring the different b-values (b-400, b-600, b-800, and b-1000). These measurements were compared with the histopathology results. Statistical analysis included t test, analysis of variance, and area under the curve for receiver operating characteristic (ROC). RESULTS There were 17 patients without rejection and 15 patients with liver graft rejection diagnosed by histopathology. The mean (SD) results between the nonrejection and rejection groups were as follows: b-400 = 1.568 (0.265) vs 1.519 (0.119) (P = .089), b-600 = 1.380 (0.181) vs 1.284 (0.106) (P = .039), b-800 = 1.262 (0.170) vs 1.170 (0.086) (P = .035), b-1000 = 1.109 (0.129) vs 1.098 (0.078) (P = .095); B-values × 10-3 mm2/s. Only b-600 (P = .04) and b-800 (P = .04) values have significant differences between the 2 groups. B-600 showed 90.48% sensitivity and 83.33% specificity (ROC area under the curve = 0.784; P < .001), and b-800 showed 90.38% sensitivity and 83.03% specificity (ROC area under the curve = 0.816; P < .001). The values obtained with the apparent diffusion coefficient in b-800 were clearly differentiated between the mild, moderate, and severe degrees of rejection (P < .001). CONCLUSION Measurement of b-600 and b-800 values using DWMRI may be used for the diagnosis of graft rejection after LT.
Collapse
Affiliation(s)
- C-C Lin
- Department of Diagnostic Radiology, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - H-Y Ou
- Department of Diagnostic Radiology, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Y-H Chuang
- Department of Diagnostic Radiology, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - H-J Chiang
- Department of Diagnostic Radiology, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - C-C Yu
- Department of Diagnostic Radiology, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - M Lazo
- Department of Diagnostic Radiology, St. Luke's Medical Center-Global City, Metro Malila, Philippines
| | - L L-C Tsang
- Department of Diagnostic Radiology, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - T-L Huang
- Department of Diagnostic Radiology, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - C-C Lin
- Liver Transplantation Program and Departments of Surgery, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - C-L Chen
- Liver Transplantation Program and Departments of Surgery, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan
| | - Y-F Cheng
- Department of Diagnostic Radiology, Kaohsiung Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Kaohsiung, Taiwan.
| |
Collapse
|
43
|
Chevallier O, Zhou N, He J, Loffroy R, Wáng YXJ. Removal of evidential motion-contaminated and poorly fitted image data improves IVIM diffusion MRI parameter scan-rescan reproducibility. Acta Radiol 2018; 59:1157-1167. [PMID: 29430937 DOI: 10.1177/0284185118756949] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Background It has been reported that intravoxel incoherent motion (IVIM) diffusion magnetic resonance imaging (MRI) scan-rescan reproducibility is unsatisfactory. Purpose To study IVIM MRI parameter reproducibility for liver parenchyma after the removal of motion-contaminated and/or poorly fitted image data. Material and Methods Eighteen healthy volunteers had liver scans twice in the same session to assess scan-rescan repeatability, and again in another session after an average interval of 13 days to assess reproducibility. Diffusion-weighted images were acquired with a 3-T scanner using respiratory-triggered echo-planar sequence and 16 b-values (0-800 s/mm2). Measurement was performed on the right liver with segment-unconstrained least square fitting. Image series with evidential anatomical mismatch, apparent artifacts, and poorly fitted signal intensity vs. b-value curve were excluded. A minimum of three slices was deemed necessary for IVIM parameter estimation. Results With a total 54 examinations, six did not satisfy inclusion criteria, leading to a success rate of 89%, and 14 volunteers were finally included for the repeatability/reproducibility study. A total of 3-10 slices per examination (mean = 5.3 slices, median = 5 slices) were utilized for analysis. Using threshold b-value = 80 s/mm2, the coefficient of variation and within-subject coefficient of variation for repeatability were 2.86% and 3.36% for Dslow, 3.81% and 4.24% for perfusion fraction (PF), 18.16% and 24.88% for Dfast; and those for reproducibility were 2.48% and 3.24% for Dslow, 4.91% and 5.38% for PF, and 21.18% and 30.89% for Dfast. Conclusion Removal of motion-contaminated and/or poorly fitted image data improves IVIM parameter reproducibility.
Collapse
Affiliation(s)
- Olivier Chevallier
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, New Territories, Hong Kong SAR
- Department of Vascular and Interventional Radiology, University of Bourgogne/Franche-Comté, François-Mitterrand Teaching Hospital, Dijon Cedex, France
| | - Nan Zhou
- Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, PR China
| | - Jian He
- Department of Radiology, Nanjing Drum Tower Hospital, The Affiliated Hospital of Nanjing University Medical School, Nanjing, PR China
| | - Romaric Loffroy
- Department of Vascular and Interventional Radiology, University of Bourgogne/Franche-Comté, François-Mitterrand Teaching Hospital, Dijon Cedex, France
| | - Yì Xiáng J Wáng
- Department of Imaging and Interventional Radiology, Faculty of Medicine, The Chinese University of Hong Kong, New Territories, Hong Kong SAR
| |
Collapse
|
44
|
Reproducibility of intravoxel incoherent motion of liver on a 3.0T scanner: free-breathing and respiratory-triggered sequences acquired with different numbers of excitations. Pol J Radiol 2018; 83:e437-e445. [PMID: 30655921 PMCID: PMC6334093 DOI: 10.5114/pjr.2018.79651] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2018] [Accepted: 05/29/2018] [Indexed: 12/31/2022] Open
Abstract
Purpose To optimise the intravoxel incoherent motion (IVIM) imaging of the liver on a 3.0T scanner by assessing parameter reproducibility on free-breathing (FB) and respiratory-triggered (RT) sequences acquired with different numbers of signal averages (NSA). Material and methods In this prospective study 20 subjects (M/F: 10/10; age: 25-62 years, mean: 39 years) underwent IVIM magnetic resonance imaging (MRI) on a 3.0T scanner using an 18-channel phase-arrayed coil and four different echo-planar sequences, each with 10 b values: 0, 10, 30, 50, 75, 100, 150, 200, 500, and 900 s/mm2. Images were acquired with FB and RT with NSA = 1-4 (FBNSA1-4, RTNSA1-4) and with NSA = 3-6 (FBNSA3-6, RTNSA3-6). Subsequently, for the assessment of reproducibility of IVIM-derived parameters (f, D, D*), each subject was scanned again with an identical protocol during the same session. IVIM parameters were calculated. The distribution of IVIM-parameters for each DWI sequence were given as the median value with first and third quartile. Inter-scan reproducibility for each IVIM parameter was evaluated using coefficient of variance and Bland-Altman difference. Differences between FB sequence and RT sequence were tested using non-parametric Wilcoxon signed-rank test. Results Mean coefficient of variance (%) for f, D, and D* ranged from 60 to 64, from 58 to 84, and from 82 to 99 for FBNSA1-4 sequence; from 50 to 69, from 41 to 97, and from 80 to 82 for RTNSA1-4 sequence; from 22 to 27, 15, and from 70 to 80 for FBNSA3-6 sequence; and from 21 to 32, from 12 to, and from 50 to 80 for RTNSA3-6 sequence, respectively. Conclusions Increasing the number of signal averages for IVIM acquisitions allows us to improve the reproducibility of IVIM-derived parameters. The sequence acquired during free-breathing with NSA = 3-6 was optimal in terms of reproducibility and acquisition time.
Collapse
|
45
|
Aumann EK, Server S, Koyuncu Sokmen B, Oz A, Namal E, Gurcan NI, Balci NC, Tokat Y. Diagnostic performances of intravoxel incoherent motion and conventional diffusion-weighted imaging in the differential diagnosis of benign and malignant portal vein thrombus. Abdom Radiol (NY) 2018; 43:2270-2276. [PMID: 29411058 DOI: 10.1007/s00261-018-1467-6] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
PURPOSE To evaluate the diagnostic accuracy of intravoxel incoherent motion (IVIM) and diffusion-weighted imaging (DWI) parameters in the differential diagnosis of portal vein thrombus (PVT). METHODOLOGY Thirty-five patients with PVT were enrolled in this retrospective study. Precontrast axial in-phase and out-of-phase T1-weighted (W) turbo field echo (TFE), axial and coronal T2-W single-shot turbo spin echo, IVIM with b values between 0 and 1300 s/mm2 and conventional DWI with b factors of 50, 400, and 800 s/mm2 with single-shot echo-planar imaging, and postcontrast dynamic T1-W volumetric interpolated breath-hold examination images obtained with 1.5 T MR unit were evaluated. For quantitative analysis of conventional DWI, an ADC map was reconstructed from conventional DWI using all b values. For quantitative evaluation of IVIM, the SI was calculated from each b value. A specific software program was applied to calculate D (true diffusion coefficient), D* (pseudodiffusion coefficient associated with blood flow), and f (perfusion fraction). The differentiation between benign and malignant PVT was based on the criteria outlined in the study by Catalano et al. (Radiology 254:154-162, 2010). RESULTS The ADC values of the malignant PVT were significantly lower than those of benign PVTs (p = 0.005). Malignant PVTs had a tendency to show higher f values in comparison with benign PVTs without statistical significance (p = 0.750). The best discriminative parameter was ADC values, which demonstrated a sensitivity of 80.0% and a specificity of 72.7% with cut-off value of 1.00 × 10-3 mm2/s. CONCLUSION ADC values might be more superior tool than IVIM parameters in differentiation between malignant and benign PVT.
Collapse
|
46
|
Sun H, Liu K, Liu H, Ji Z, Yan Y, Jiang L, Zhou J. Comparison of bi-exponential and mono-exponential models of diffusion-weighted imaging for detecting active sacroiliitis in ankylosing spondylitis. Acta Radiol 2018; 59:468-477. [PMID: 28741366 DOI: 10.1177/0284185117722811] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
Background There has been a growing need for a sensitive and effective imaging method for the differentiation of the activity of ankylosing spondylitis (AS). Purpose To compare the performances of intravoxel incoherent motion (IVIM)-derived parameters and the apparent diffusion coefficient (ADC) for distinguishing AS-activity. Material and Methods One hundred patients with AS were divided into active (n = 51) and non-active groups (n = 49) and 21 healthy volunteers were included as control. The ADC, diffusion coefficient ( D), pseudodiffusion coefficient ( D*), and perfusion fraction ( f) were calculated for all groups. Kruskal-Wallis tests and receiver operator characteristic (ROC) curve analysis were performed for all parameters. Results There was good reproducibility of ADC /D and relatively poor reproducibility of D*/f. ADC, D, and f were significantly higher in the active group than in the non-active and control groups (all P < 0.0001, respectively). D* was slightly but significant lower in the active group than in the non-active and control group ( P = 0.0064, 0.0215). There was no significant difference in any parameter between the non-active group and the control group (all P > 0.050). In the ROC analysis, ADC had the largest AUC for distinguishing between the active group and the non-active group (0.988) and between the active and control groups (0.990). Multivariate logistic regression analysis models showed no diagnostic improvement. Conclusion ADC provided better diagnostic performance than IVIM-derived parameters in differentiating AS activity. Therefore, a straightforward and effective mono-exponential model of diffusion-weighted imaging may be sufficient for differentiating AS activity in the clinic.
Collapse
Affiliation(s)
- Haitao Sun
- Department of Radiology, Zhongshan Hospital, Fudan University and Shanghai Medical Imaging Institute, Department of Medical Imaging, Shanghai Medical School of Fudan University, Shanghai, PR China
| | - Kai Liu
- Department of Radiology, Zhongshan Hospital, Fudan University and Shanghai Medical Imaging Institute, Department of Medical Imaging, Shanghai Medical School of Fudan University, Shanghai, PR China
| | - Hao Liu
- Department of Radiology, Zhongshan Hospital, Fudan University and Shanghai Medical Imaging Institute, Department of Medical Imaging, Shanghai Medical School of Fudan University, Shanghai, PR China
| | - Zongfei Ji
- Department of Rheumatology, Zhongshan Hospital, Fudan University, Shanghai, PR China
| | - Yan Yan
- Department of Rheumatology, Zhongshan Hospital, Fudan University, Shanghai, PR China
| | - Lindi Jiang
- Department of Rheumatology, Zhongshan Hospital, Fudan University, Shanghai, PR China
| | - Jianjun Zhou
- Department of Radiology, Zhongshan Hospital, Fudan University and Shanghai Medical Imaging Institute, Department of Medical Imaging, Shanghai Medical School of Fudan University, Shanghai, PR China
| |
Collapse
|
47
|
Luo M, Zhang L, Jiang XH, Zhang WD. Intravoxel incoherent motion: application in differentiation of hepatocellular carcinoma and focal nodular hyperplasia. Diagn Interv Radiol 2018; 23:263-271. [PMID: 28703102 DOI: 10.5152/dir.2017.16595] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
PURPOSE We aimed to explore whether intravoxel incoherent motion (IVIM)-related parameters of hepatocellular carcinoma (HCC) and focal nodular hyperplasia (FNH) demonstrate differences that could be used to differentiate and improve diagnostic efficiency. METHODS A total of 27 patients, including 22 with HCC and 5 with FNH, underwent liver 3.0 T magnetic resonance imaging for routine sequences. They were concurrently examined by IVIM diffusion-weighted imaging (DWI) scanning with 11 different b values (0-800 s/mm2). IVIM-derived parameters, such as pure diffusion coefficient (D), pseudo-diffusion coefficient (D*), perfusion fraction (f), and apparent diffusion coefficient (ADCtotal), were quantified automatically by post-processing software and compared between HCC and FNH groups. A receiver operating characteristic (ROC) curve was then created to predict their diagnostic value. RESULTS D* was weak in terms of reproducibility among the other parameters. ADCtotal, D, and D* were significantly lower in the HCC group than in the FNH group, while f did not show a significant difference. ADCtotal and D had the largest area under the curve values (AUC; 0.915 and 0.897, respectively) and similarly high efficacy to differentiate the two conditions. CONCLUSION IVIM provides a new modality to differentiate the HCC and FNH. ADCtotal and D demonstrated outstanding and comparable diagnosing utility.
Collapse
Affiliation(s)
- Ma Luo
- Department of Radiology, Sun Yat-sen University Cancer Center, State Key Laboratory of Oncology in South China, Collaborative Innovation Center for Cancer Medicine, Guangzhou, Guangdong, China.
| | | | | | | |
Collapse
|
48
|
Hu F, Yang R, Huang Z, Wang M, Zhang H, Yan X, Song B. Liver fibrosis: in vivo evaluation using intravoxel incoherent motion-derived histogram metrics with histopathologic findings at 3.0 T. Abdom Radiol (NY) 2017. [PMID: 28624925 DOI: 10.1007/s00261-017-1208-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Abstract
PURPOSE To retrospectively determine the feasibility of intravoxel incoherent motion (IVIM) imaging based on histogram analysis for the staging of liver fibrosis (LF) using histopathologic findings as the reference standard. METHODS 56 consecutive patients (14 men, 42 women; age range, 15-76, years) with chronic liver diseases (CLDs) were studied using IVIM-DWI with 9 b-values (0, 25, 50, 75, 100, 150, 200, 500, 800 s/mm2) at 3.0 T. Fibrosis stage was evaluated using the METAVIR scoring system. Histogram metrics including mean, standard deviation (Std), skewness, kurtosis, minimum (Min), maximum (Max), range, interquartile (Iq) range, and percentiles (10, 25, 50, 75, 90th) were extracted from apparent diffusion coefficient (ADC), true diffusion coefficient (D), pseudo-diffusion coefficient (D*), and perfusion fraction (f) maps. All histogram metrics among different fibrosis groups were compared using one-way analysis of variance or nonparametric Kruskal-Wallis test. For significant parameters, receivers operating characteristic curve (ROC) analyses were further performed for the staging of LF. RESULTS Based on their METAVIR stage, the 56 patients were reclassified into three groups as follows: F0-1 group (n = 25), F2-3 group (n = 21), and F4 group (n = 10). The mean, Iq range, percentiles (50, 75, and 90th) of D* maps between the groups were significant differences (all P < 0.05). Area under the ROC curve (AUC) of the mean, Iq range, 50, 75, and 90th percentile of D* maps for identifying significant LF (≥F2 stage) was 0.901, 0.859, 0.876, 0.943, and 0.886 (all P < 0.0001), respectively; for diagnosing severe fibrosis or cirrhosis (F4), AUC was 0.917, 0.922, 0.943, 0.985, and 0.939 (all P < 0.0001), respectively. The histogram metrics of ADC, D, and f maps demonstrated no significant difference among the groups (all P > 0.05). CONCLUSION Histogram analysis of D* map derived from IVIM can be used to stage liver fibrosis in patients with CLDs and provide more quantitative information beyond the mean value.
Collapse
Affiliation(s)
- Fubi Hu
- Department of Radiology, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan, China
- Department of Radiology, The First Affiliated Hospital of Chengdu Medical College, 278# Baoguang Road, Xindu District, Chengdu, Sichuan, China
| | - Ru Yang
- Department of Radiology, The First Affiliated Hospital of Chengdu Medical College, 278# Baoguang Road, Xindu District, Chengdu, Sichuan, China
| | - Zixing Huang
- Department of Radiology, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan, China
| | - Min Wang
- Department of Radiology, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan, China
| | - Hanmei Zhang
- Department of Radiology, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan, China
| | - Xu Yan
- Siemens Healthcare, MR Collaborations NE Asia, Shanghai, China
| | - Bin Song
- Department of Radiology, West China Hospital, Sichuan University, 37# Guoxue Road, Chengdu, Sichuan, China.
| |
Collapse
|
49
|
Lecler A, Savatovsky J, Balvay D, Zmuda M, Sadik JC, Galatoire O, Charbonneau F, Bergès O, Picard H, Fournier L. Repeatability of apparent diffusion coefficient and intravoxel incoherent motion parameters at 3.0 Tesla in orbital lesions. Eur Radiol 2017; 27:5094-5103. [PMID: 28677061 PMCID: PMC5674133 DOI: 10.1007/s00330-017-4933-6] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2017] [Revised: 06/06/2017] [Accepted: 06/07/2017] [Indexed: 02/07/2023]
Abstract
OBJECTIVES To evaluate repeatability of intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) parameters in the orbit. METHODS From December 2015 to March 2016, 22 patients were scanned twice using an IVIM sequence with 15b values (0-2,000 s/mm2) at 3.0T. Two readers independently delineated regions of interest in an orbital mass and in different intra-orbital and extra-orbital structures. Short-term test-retest repeatability and inter-observer agreement were assessed using the intra-class correlation coefficient (ICC), the coefficient of variation (CV) and Bland-Altman limits of agreements (BA-LA). RESULTS Test-retest repeatability of IVIM parameters in the orbital mass was satisfactory for ADC and D (mean CV 12% and 14%, ICC 95% and 93%), poor for f and D*(means CV 43% and 110%, ICC 90% and 65%). Inter-observer repeatability agreement was almost perfect in the orbital mass for all the IVIM parameters (ICC = 95%, 93%, 94% and 90% for ADC, D, f and D*, respectively). CONCLUSIONS IVIM appeared to be a robust tool to measure D in orbital lesions with good repeatability, but this approach showed a poor repeatability of f and D*. KEY POINTS • IVIM technique is feasible in the orbit. • IVIM has a good-acceptable repeatability of D (CV range 12-25 %). • IVIM interobserver repeatability agreement is excellent (ICC range 90-95 %). • f or D* provide higher test-retest and interobserver variabilities.
Collapse
Affiliation(s)
- Augustin Lecler
- Department of Radiology, Fondation Ophtalmologique Adolphe de Rothschild, 29 rue Manin, 75019, Paris, France.
- Université Paris Descartes Sorbonne Paris Cité, INSERM UMR-S970, Cardiovascular Research Centre - PARCC, Paris, France.
| | - Julien Savatovsky
- Department of Radiology, Fondation Ophtalmologique Adolphe de Rothschild, 29 rue Manin, 75019, Paris, France
| | - Daniel Balvay
- Université Paris Descartes Sorbonne Paris Cité, INSERM UMR-S970, Cardiovascular Research Centre - PARCC, Paris, France
| | - Mathieu Zmuda
- Department of Orbitopalpebral Surgery, Fondation Ophtalmologique Adolphe de Rothschild, Paris, France
| | - Jean-Claude Sadik
- Department of Radiology, Fondation Ophtalmologique Adolphe de Rothschild, 29 rue Manin, 75019, Paris, France
| | - Olivier Galatoire
- Department of Orbitopalpebral Surgery, Fondation Ophtalmologique Adolphe de Rothschild, Paris, France
| | - Frédérique Charbonneau
- Department of Radiology, Fondation Ophtalmologique Adolphe de Rothschild, 29 rue Manin, 75019, Paris, France
| | - Olivier Bergès
- Department of Radiology, Fondation Ophtalmologique Adolphe de Rothschild, 29 rue Manin, 75019, Paris, France
| | - Hervé Picard
- Clinical Research Unit, Fondation Ophtalmologique Adolphe de Rothschild, Paris, France
| | - Laure Fournier
- Université Paris Descartes Sorbonne Paris Cité, INSERM UMR-S970, Cardiovascular Research Centre - PARCC, Paris, France
- Assistance Publique-Hôpitaux de Paris, Hôpital Européen Georges Pompidou, Radiology Department, Université Paris Descartes Sorbonne Paris Cité, Paris, France
| |
Collapse
|
50
|
Federau C. Intravoxel incoherent motion MRI as a means to measure in vivo perfusion: A review of the evidence. NMR IN BIOMEDICINE 2017; 30. [PMID: 28885745 DOI: 10.1002/nbm.3780] [Citation(s) in RCA: 57] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/03/2017] [Revised: 06/19/2017] [Accepted: 07/07/2017] [Indexed: 05/07/2023]
Abstract
The idea that in vivo intravoxel incoherent motion magnetic resonance signal is influenced by blood motion in the microvasculature is exciting, because it suggests that local and quantitative perfusion information can be obtained in a simple and elegant way from a few diffusion-weighted images, without contrast injection. When the method was proposed in the late 1980s some doubts appeared as to its feasibility, and, probably because the signal to noise and image quality at the time was not sufficient, no obvious experimental evidence could be produced to alleviate them. Helped by the tremendous improvements seen in the last three decades in MR hardware, pulse design, and post-processing capabilities, an increasing number of encouraging reports on the value of intravoxel incoherent motion perfusion imaging have emerged. The aim of this article is to review the current published evidence on the feasibility of in vivo perfusion imaging with intravoxel incoherent motion MRI.
Collapse
Affiliation(s)
- Christian Federau
- Division of Diagnostic and Interventional Neuroradiology, Department of Radiology, University Hospital Basel, Petersgraben, Basle, Switzerland
| |
Collapse
|