1
|
Bilal M, Syed NN, Jamil Y, Tariq A, Khan HR. Powering the future: Exploring self-charging cardiac implantable electronic devices and the Qi revolution. Pacing Clin Electrophysiol 2024; 47:542-550. [PMID: 38407386 DOI: 10.1111/pace.14955] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/21/2023] [Revised: 01/23/2024] [Accepted: 02/08/2024] [Indexed: 02/27/2024]
Abstract
The incidence and prevalence of cardiovascular diseases (CVD) have risen over the last few decades worldwide, resulting in a cost burden to healthcare systems and increasingly complex procedures. Among many strategies for treating heart diseases, treating arrhythmias using cardiac implantable electronic devices (CIEDs) has been shown to improve quality of life and reduce the incidence of sudden cardiac death. The battery-powered CIEDs have the inherent challenge of regular battery replacements depending upon energy usage for their programmed tasks. Nanogenerator-based energy harvesters have been extensively studied, developed, and optimized continuously in recent years to overcome this challenge owing to their merits of self-powering abilities and good biocompatibility. Although these nanogenerators and others currently used in energy harvesters, such as biofuel cells (BFCs) exhibit an infinite spectrum of uses for this novel technology, their demerits should not be dismissed. Despite the emergence of Qi wireless power transfer (WPT) has revolutionized the technological world, its application in CIEDs has yet to be studied well. This review outlines the working principles and applications of currently employed energy harvesters to provide a preliminary exploration of CIEDs based on Qi WPT, which may be a promising technology for the next generation of functionalized CIEDs.
Collapse
Affiliation(s)
- Maham Bilal
- Dow University of Health Sciences, Karachi, Pakistan
| | | | - Yumna Jamil
- Dow University of Health Sciences, Karachi, Pakistan
| | - Areesha Tariq
- Dow University of Health Sciences, Karachi, Pakistan
| | - Habib Rehman Khan
- Division of Cardiology, London Health Sciences, Schulich Medical School, Western University, London, Ontario, Canada
| |
Collapse
|
2
|
Bhatia A, Hanna J, Stuart T, Kasper KA, Clausen DM, Gutruf P. Wireless Battery-free and Fully Implantable Organ Interfaces. Chem Rev 2024; 124:2205-2280. [PMID: 38382030 DOI: 10.1021/acs.chemrev.3c00425] [Citation(s) in RCA: 6] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/23/2024]
Abstract
Advances in soft materials, miniaturized electronics, sensors, stimulators, radios, and battery-free power supplies are resulting in a new generation of fully implantable organ interfaces that leverage volumetric reduction and soft mechanics by eliminating electrochemical power storage. This device class offers the ability to provide high-fidelity readouts of physiological processes, enables stimulation, and allows control over organs to realize new therapeutic and diagnostic paradigms. Driven by seamless integration with connected infrastructure, these devices enable personalized digital medicine. Key to advances are carefully designed material, electrophysical, electrochemical, and electromagnetic systems that form implantables with mechanical properties closely matched to the target organ to deliver functionality that supports high-fidelity sensors and stimulators. The elimination of electrochemical power supplies enables control over device operation, anywhere from acute, to lifetimes matching the target subject with physical dimensions that supports imperceptible operation. This review provides a comprehensive overview of the basic building blocks of battery-free organ interfaces and related topics such as implantation, delivery, sterilization, and user acceptance. State of the art examples categorized by organ system and an outlook of interconnection and advanced strategies for computation leveraging the consistent power influx to elevate functionality of this device class over current battery-powered strategies is highlighted.
Collapse
Affiliation(s)
- Aman Bhatia
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Jessica Hanna
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Tucker Stuart
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Kevin Albert Kasper
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - David Marshall Clausen
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
| | - Philipp Gutruf
- Department of Biomedical Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Department of Electrical and Computer Engineering, The University of Arizona, Tucson, Arizona 85721, United States
- Bio5 Institute, The University of Arizona, Tucson, Arizona 85721, United States
- Neuroscience Graduate Interdisciplinary Program (GIDP), The University of Arizona, Tucson, Arizona 85721, United States
| |
Collapse
|
3
|
Kausaite-Minkstimiene A, Kaminskas A, Gayda G, Ramanaviciene A. Towards a Self-Powered Amperometric Glucose Biosensor Based on a Single-Enzyme Biofuel Cell. BIOSENSORS 2024; 14:138. [PMID: 38534245 DOI: 10.3390/bios14030138] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/09/2024] [Revised: 02/20/2024] [Accepted: 03/05/2024] [Indexed: 03/28/2024]
Abstract
This paper describes the study of an amperometric glucose biosensor based on an enzymatic biofuel cell consisting of a bioanode and a biocathode modified with the same enzyme-glucose oxidase (GOx). A graphite rod electrode (GRE) was electrochemically modified with a layer of Prussian blue (PB) nanoparticles embedded in a poly(pyrrole-2-carboxylic acid) (PPCA) shell, and an additional layer of PPCA and was used as the cathode. A GRE modified with a nanocomposite composed of poly(1,10-phenanthroline-5,6-dione) (PPD) and gold nanoparticles (AuNPs) entrapped in a PPCA shell was used as an anode. Both electrodes were modified with GOx by covalently bonding the enzyme to the carboxyl groups of PPCA. The developed biosensor exhibited a wide linear range of 0.15-124.00 mM with an R2 of 0.9998 and a sensitivity of 0.16 μA/mM. The limit of detection (LOD) and quantification (LOQ) were found to be 0.07 and 0.23 mM, respectively. The biosensor demonstrated exceptional selectivity to glucose and operational stability throughout 35 days, as well as good reproducibility, repeatability, and anti-interference ability towards common interfering substances. The studies on human serum demonstrate the ability of the newly designed biosensor to determine glucose in complex real samples at clinically relevant concentrations.
Collapse
Affiliation(s)
- Asta Kausaite-Minkstimiene
- NanoTechnas-Center of Nanotechnology and Materials Science, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT-03225 Vilnius, Lithuania
| | - Algimantas Kaminskas
- NanoTechnas-Center of Nanotechnology and Materials Science, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT-03225 Vilnius, Lithuania
| | - Galina Gayda
- Department of Analytical Biotechnology, Institute of Cell Biology National Academy of Sciences of Ukraine (ICB NASU), Dragomanov St. 14/16, 79005 Lviv, Ukraine
| | - Almira Ramanaviciene
- NanoTechnas-Center of Nanotechnology and Materials Science, Institute of Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, Naugarduko St. 24, LT-03225 Vilnius, Lithuania
| |
Collapse
|
4
|
Yue O, Wang X, Xie L, Bai Z, Zou X, Liu X. Biomimetic Exogenous "Tissue Batteries" as Artificial Power Sources for Implantable Bioelectronic Devices Manufacturing. ADVANCED SCIENCE (WEINHEIM, BADEN-WURTTEMBERG, GERMANY) 2024; 11:e2307369. [PMID: 38196276 PMCID: PMC10953594 DOI: 10.1002/advs.202307369] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/04/2023] [Revised: 11/27/2023] [Indexed: 01/11/2024]
Abstract
Implantable bioelectronic devices (IBDs) have gained attention for their capacity to conformably detect physiological and pathological signals and further provide internal therapy. However, traditional power sources integrated into these IBDs possess intricate limitations such as bulkiness, rigidity, and biotoxicity. Recently, artificial "tissue batteries" (ATBs) have diffusely developed as artificial power sources for IBDs manufacturing, enabling comprehensive biological-activity monitoring, diagnosis, and therapy. ATBs are on-demand and designed to accommodate the soft and confining curved placement space of organisms, minimizing interface discrepancies, and providing ample power for clinical applications. This review presents the near-term advancements in ATBs, with a focus on their miniaturization, flexibility, biodegradability, and power density. Furthermore, it delves into material-screening, structural-design, and energy density across three distinct categories of TBs, distinguished by power supply strategies. These types encompass innovative energy storage devices (chemical batteries and supercapacitors), power conversion devices that harness power from human-body (biofuel cells, thermoelectric nanogenerators, bio-potential devices, piezoelectric harvesters, and triboelectric devices), and energy transfer devices that receive and utilize external energy (radiofrequency-ultrasound energy harvesters, ultrasound-induced energy harvesters, and photovoltaic devices). Ultimately, future challenges and prospects emphasize ATBs with the indispensability of bio-safety, flexibility, and high-volume energy density as crucial components in long-term implantable bioelectronic devices.
Collapse
Affiliation(s)
- Ouyang Yue
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- National Demonstration Center for Experimental Light Chemistry Engineering EducationShaanxi University of Science &TechnologyXi'anShaanxi710021China
| | - Xuechuan Wang
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- College of Chemistry and Chemical EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
| | - Long Xie
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- College of Chemistry and Chemical EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
| | - Zhongxue Bai
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- National Demonstration Center for Experimental Light Chemistry Engineering EducationShaanxi University of Science &TechnologyXi'anShaanxi710021China
| | - Xiaoliang Zou
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- National Demonstration Center for Experimental Light Chemistry Engineering EducationShaanxi University of Science &TechnologyXi'anShaanxi710021China
| | - Xinhua Liu
- College of Bioresources Chemical and Materials EngineeringShaanxi University of Science & TechnologyXi'anShaanxi710021China
- National Demonstration Center for Experimental Light Chemistry Engineering EducationShaanxi University of Science &TechnologyXi'anShaanxi710021China
| |
Collapse
|
5
|
Zhou J, Zhou S, Fan P, Li X, Ying Y, Ping J, Pan Y. Implantable Electrochemical Microsensors for In Vivo Monitoring of Animal Physiological Information. NANO-MICRO LETTERS 2023; 16:49. [PMID: 38087121 PMCID: PMC10716106 DOI: 10.1007/s40820-023-01274-4] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Accepted: 10/24/2023] [Indexed: 10/11/2024]
Abstract
In vivo monitoring of animal physiological information plays a crucial role in promptly alerting humans to potential diseases in animals and aiding in the exploration of mechanisms underlying human diseases. Currently, implantable electrochemical microsensors have emerged as a prominent area of research. These microsensors not only fulfill the technical requirements for monitoring animal physiological information but also offer an ideal platform for integration. They have been extensively studied for their ability to monitor animal physiological information in a minimally invasive manner, characterized by their bloodless, painless features, and exceptional performance. The development of implantable electrochemical microsensors for in vivo monitoring of animal physiological information has witnessed significant scientific and technological advancements through dedicated efforts. This review commenced with a comprehensive discussion of the construction of microsensors, including the materials utilized and the methods employed for fabrication. Following this, we proceeded to explore the various implantation technologies employed for electrochemical microsensors. In addition, a comprehensive overview was provided of the various applications of implantable electrochemical microsensors, specifically in the monitoring of diseases and the investigation of disease mechanisms. Lastly, a concise conclusion was conducted on the recent advancements and significant obstacles pertaining to the practical implementation of implantable electrochemical microsensors.
Collapse
Affiliation(s)
- Jin Zhou
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China
| | - Shenghan Zhou
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China
| | - Peidi Fan
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China
| | - Xunjia Li
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311200, People's Republic of China
| | - Yibin Ying
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311200, People's Republic of China
| | - Jianfeng Ping
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China.
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311200, People's Republic of China.
| | - Yuxiang Pan
- Laboratory of Agricultural Information Intelligent Sensing, College of Biosystems Engineering and Food Science, Zhejiang University, Hangzhou, 310058, People's Republic of China.
- ZJU-Hangzhou Global Scientific and Technological Innovation Center, Zhejiang University, Hangzhou, 311200, People's Republic of China.
| |
Collapse
|
6
|
Garland NT, Kaveti R, Bandodkar AJ. Biofluid-Activated Biofuel Cells, Batteries, and Supercapacitors: A Comprehensive Review. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2023; 35:e2303197. [PMID: 37358398 DOI: 10.1002/adma.202303197] [Citation(s) in RCA: 15] [Impact Index Per Article: 7.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/05/2023] [Revised: 06/06/2023] [Indexed: 06/27/2023]
Abstract
Recent developments in wearable and implanted devices have resulted in numerous, unprecedented capabilities that generate increasingly detailed information about a user's health or provide targeted therapy. However, options for powering such systems remain limited to conventional batteries which are large and have toxic components and as such are not suitable for close integration with the human body. This work provides an in-depth overview of biofluid-activated electrochemical energy devices, an emerging class of energy sources judiciously designed for biomedical applications. These unconventional energy devices are composed of biocompatible materials that harness the inherent chemistries of various biofluids to produce useable electrical energy. This work covers examples of such biofluid-activated energy devices in the form of biofuel cells, batteries, and supercapacitors. Advances in materials, design engineering, and biotechnology that form the basis for high-performance, biofluid-activated energy devices are discussed. Innovations in hybrid manufacturing and heterogeneous integration of device components to maximize power output are also included. Finally, key challenges and future scopes of this nascent field are provided.
Collapse
Affiliation(s)
- Nate T Garland
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27606, USA
- Center for Advanced Self-Powered Systems of Integrated Sensors and Technologies (ASSIST), North Carolina State University, Raleigh, NC, 27606, USA
| | - Rajaram Kaveti
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27606, USA
- Center for Advanced Self-Powered Systems of Integrated Sensors and Technologies (ASSIST), North Carolina State University, Raleigh, NC, 27606, USA
| | - Amay J Bandodkar
- Department of Electrical and Computer Engineering, North Carolina State University, Raleigh, NC, 27606, USA
- Center for Advanced Self-Powered Systems of Integrated Sensors and Technologies (ASSIST), North Carolina State University, Raleigh, NC, 27606, USA
| |
Collapse
|
7
|
Kosugi M, Tatara R, Fujii Y, Komaba S. Surfactant-Free Formate/O 2 Biofuel Cell with Electropolymerized Phenothiazine Derivative-Modified Enzymatic Bioanode. ACS APPLIED BIO MATERIALS 2023; 6:4304-4313. [PMID: 37750824 PMCID: PMC10583231 DOI: 10.1021/acsabm.3c00502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2023] [Accepted: 09/06/2023] [Indexed: 09/27/2023]
Abstract
A formate (HCOO-) bioanode was developed by utilizing a phenothiazine-based electropolymerized layer deposited on sucrose-derived carbon. The electrode modified with NAD-dependent formate dehydrogenase and the electropolymerized layer synergistically catalyzed the oxidation of the coenzyme (NADH) and fuel (HCOO-) to achieve efficient electron transfer. Further, the replacement of carbon nanotubes with water-dispersible sucrose-derived carbon used as the electrode base allowed the fabrication of a surfactant-free bioanode delivering a maximum current density of 1.96 mA cm-2 in the fuel solution. Finally, a separator- and surfactant-free HCOO-/O2 biofuel cell featuring the above bioanode and a gas-diffusion biocathode modified with bilirubin oxidase and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonate) was fabricated, delivering a maximum power density of 70 μW cm-2 (at 0.24 V) and an open-circuit voltage of 0.59 V. Thus, this study demonstrates the potential of formic acid as a fuel and possibilities for the application of carbon materials in bioanodes.
Collapse
Affiliation(s)
- Motohiro Kosugi
- Department of Applied Chemistry, Tokyo University of Science, Shinjuku, Tokyo 162-8601, Japan
| | - Ryoichi Tatara
- Department of Applied Chemistry, Tokyo University of Science, Shinjuku, Tokyo 162-8601, Japan
| | - Yuki Fujii
- Department of Applied Chemistry, Tokyo University of Science, Shinjuku, Tokyo 162-8601, Japan
| | - Shinichi Komaba
- Department of Applied Chemistry, Tokyo University of Science, Shinjuku, Tokyo 162-8601, Japan
| |
Collapse
|
8
|
Ma Z, Zhao J, Yu L, Yan M, Liang L, Wu X, Xu M, Wang W, Yan S. A Review of Energy Supply for Biomachine Hybrid Robots. CYBORG AND BIONIC SYSTEMS 2023; 4:0053. [PMID: 37766796 PMCID: PMC10521967 DOI: 10.34133/cbsystems.0053] [Citation(s) in RCA: 12] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2023] [Accepted: 09/02/2023] [Indexed: 09/29/2023] Open
Abstract
Biomachine hybrid robots have been proposed for important scenarios, such as wilderness rescue, ecological monitoring, and hazardous area surveying. The energy supply unit used to power the control backpack carried by these robots determines their future development and practical application. Current energy supply devices for control backpacks are mainly chemical batteries. To achieve self-powered devices, researchers have developed solar energy, bioenergy, biothermal energy, and biovibration energy harvesters. This review provides an overview of research in the development of chemical batteries and self-powered devices for biomachine hybrid robots. Various batteries for different biocarriers and the entry points for the design of self-powered devices are outlined in detail. Finally, an overview of the future challenges and possible directions for the development of energy supply devices used to biomachine hybrid robots is provided.
Collapse
Affiliation(s)
- Zhiyun Ma
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, P. R. China
| | - Jieliang Zhao
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, P. R. China
| | - Li Yu
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, P. R. China
| | - Mengdan Yan
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, P. R. China
| | - Lulu Liang
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, P. R. China
| | - Xiangbing Wu
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, P. R. China
| | - Mengdi Xu
- Department of Mechanical Engineering, Carnegie Mellon University, Pittsburgh, PA 15213, USA
| | - Wenzhong Wang
- School of Mechanical Engineering, Beijing Institute of Technology, Beijing 100081, P. R. China
| | - Shaoze Yan
- Department of Mechanical Engineering, Tsinghua University, Beijing 100084, P. R. China
| |
Collapse
|
9
|
Huang W, Zulkifli MYB, Chai M, Lin R, Wang J, Chen Y, Chen V, Hou J. Recent advances in enzymatic biofuel cells enabled by innovative materials and techniques. EXPLORATION (BEIJING, CHINA) 2023; 3:20220145. [PMID: 37933234 PMCID: PMC10624391 DOI: 10.1002/exp.20220145] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Accepted: 03/21/2023] [Indexed: 11/08/2023]
Abstract
The past few decades have seen increasingly rapid advances in the field of sustainable energy technologies. As a new bio- and eco-friendly energy source, enzymatic biofuel cells (EBFCs) have garnered significant research interest due to their capacity to power implantable bioelectronics, portable devices, and biosensors by utilizing biomass as fuel under mild circumstances. Nonetheless, numerous obstacles impeded the commercialization of EBFCs, including their relatively modest power output and poor long-term stability of enzymes. To depict the current progress of EBFC and address the challenges it faces, this review traces back the evolution of EBFC and focuses on contemporary advances such as newly emerged multi or single enzyme systems, various porous framework-enzyme composites techniques, and innovative applications. Besides emphasizing current achievements in this field, from our perspective part we also introduced novel electrode and cell design for highly effective EBFC fabrication. We believe this review will assist readers in comprehending the basic research and applications of EBFCs as well as potentially spark interdisciplinary collaboration for addressing the pressing issues in this field.
Collapse
Affiliation(s)
- Wengang Huang
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
| | - Muhammad Yazid Bin Zulkifli
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
- School of Chemical EngineeringThe University of New South WalesSydneyNew South WalesAustralia
| | - Milton Chai
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
| | - Rijia Lin
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
| | - Jingjing Wang
- Australian Institute for Bioengineering and NanotechnologyThe University of QueenslandSaint LuciaQueenslandAustralia
| | - Yuelei Chen
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
| | - Vicki Chen
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
| | - Jingwei Hou
- School of Chemical EngineeringThe University of QueenslandSaint LuciaQueenslandAustralia
| |
Collapse
|
10
|
Ramanaiah SV, Chandrasekhar K, Cordas CM, Potoroko I. Bioelectrochemical systems (BESs) for agro-food waste and wastewater treatment, and sustainable bioenergy-A review. ENVIRONMENTAL POLLUTION (BARKING, ESSEX : 1987) 2023; 325:121432. [PMID: 36907238 DOI: 10.1016/j.envpol.2023.121432] [Citation(s) in RCA: 6] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/19/2022] [Revised: 02/09/2023] [Accepted: 03/09/2023] [Indexed: 06/18/2023]
Abstract
Producing food by farming and subsequent food manufacturing are central to the world's food supply, accounting for more than half of all production. Production is, however, closely related to the creation of large amounts of organic wastes or byproducts (agro-food waste or wastewater) that negatively impact the environment and the climate. Global climate change mitigation is an urgent need that necessitates sustainable development. For that purpose, proper agro-food waste and wastewater management are essential, not only for waste reduction but also for resource optimization. To achieve sustainability in food production, biotechnology is considered as key factor since its continuous development and broad implementation will potentially benefit ecosystems by turning polluting waste into biodegradable materials; this will become more feasible and common as environmentally friendly industrial processes improve. Bioelectrochemical systems are a revitalized, promising biotechnology integrating microorganisms (or enzymes) with multifaceted applications. The technology can efficiently reduce waste and wastewater while recovering energy and chemicals, taking advantage of their biological elements' specific redox processes. In this review, a consolidated description of agro-food waste and wastewater and its remediation possibilities, using different bioelectrochemical-based systems is presented and discussed together with a critical view of the current and future potential applications.
Collapse
Affiliation(s)
- S V Ramanaiah
- Food and Biotechnology Research Lab, South Ural State University (National Research University), 454080, Chelyabinsk, Russian Federation.
| | - K Chandrasekhar
- School of Civil and Environmental Engineering, Yonsei University, 50 Yonsei-ro, Seoul, 03722, Republic of Korea
| | - Cristina M Cordas
- Laboratório Associado para a Química Verde | Associated Laboratory for Green Chemistry (LAQV) of the Network of Chemistry and Technology (REQUIMTE), Department of Chemistry, NOVA School of Science and Technology, Universidade Nova de Lisboa, 2829-516, Caparica, Portugal
| | - Irina Potoroko
- Food and Biotechnology Research Lab, South Ural State University (National Research University), 454080, Chelyabinsk, Russian Federation
| |
Collapse
|
11
|
Berezovska A, Meiller A, Marinesco S, Nedellec Y, Giroud F, Gross AJ, Cosnier S. Chlorhexidine digluconate exerts bactericidal activity vs. gram positive Staphylococci with bioelectrocatalytic compatibility: High level disinfection for implantable biofuel cells. Bioelectrochemistry 2023; 152:108435. [PMID: 37099859 DOI: 10.1016/j.bioelechem.2023.108435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 03/17/2023] [Accepted: 04/01/2023] [Indexed: 04/08/2023]
Abstract
Implanted devices destined for contact with sterile body tissues, vasculature or fluids should be free of any microbial contamination that could lead to disease transmission. The disinfection and sterilisation of implantable biofuel cells is a challenging and largely overlooked subject due to the incompatibility of fragile biocatalytic components with classical treatments. Here we report the development of a convenient "soft" chemical treatment based on immersion of enzymatic bioelectrodes and biofuel cells in dilute aqueous chlorhexidine digluconate (CHx). We show that immersion treatment in a 0.5 % solution of CHx for 5 min is sufficient to remove 10-6 log colony forming units of Staphylococcus hominis after 26 h while shorter treatments are less effective. Treatments with 0.2 % CHx solutions were ineffective. Bioelectrocatalytic half-cell voltammetry revealed no loss in activity at the bioanode after the bactericidal treatment, while the cathode was less tolerant. A maximum power output loss of ca. 10 % for the glucose/O2 biofuel cell was observed following the 5 min CHx treatment, while the dialysis bag had a significant negative impact on the power output. Finally, we report a proof-of-concept in vivo operation for 4 days of a CHx-treated biofuel cell with a 3D printed holder and additional porous surgical tissue interface. Further assessments are necessary to rigorously validate sterilisation, biocompatibility and tissue response performance.
Collapse
Affiliation(s)
- Anastasiia Berezovska
- Département de Chimie Moléculaire (DCM), Univ. Grenoble Alpes - CNRS 570 rue de la Chimie, 38041 Grenoble, France
| | - Anne Meiller
- Lyon Neuroscience Research Center, Team TIGER, BELIV technological platform, Univ. of Lyon, CNRS UMR5292, Inserm U1028, Lyon, France Centre Hospitalier Le Vinatier, Bat Neurocampus, 95 Bd Pinel, 69675 Bron cedex, France
| | - Stéphane Marinesco
- Lyon Neuroscience Research Center, Team TIGER, BELIV technological platform, Univ. of Lyon, CNRS UMR5292, Inserm U1028, Lyon, France Centre Hospitalier Le Vinatier, Bat Neurocampus, 95 Bd Pinel, 69675 Bron cedex, France
| | - Yannig Nedellec
- Département de Chimie Moléculaire (DCM), Univ. Grenoble Alpes - CNRS 570 rue de la Chimie, 38041 Grenoble, France
| | - Fabien Giroud
- Département de Chimie Moléculaire (DCM), Univ. Grenoble Alpes - CNRS 570 rue de la Chimie, 38041 Grenoble, France
| | - Andrew J Gross
- Département de Chimie Moléculaire (DCM), Univ. Grenoble Alpes - CNRS 570 rue de la Chimie, 38041 Grenoble, France.
| | - Serge Cosnier
- Département de Chimie Moléculaire (DCM), Univ. Grenoble Alpes - CNRS 570 rue de la Chimie, 38041 Grenoble, France.
| |
Collapse
|
12
|
Won SM, Cai L, Gutruf P, Rogers JA. Wireless and battery-free technologies for neuroengineering. Nat Biomed Eng 2023; 7:405-423. [PMID: 33686282 PMCID: PMC8423863 DOI: 10.1038/s41551-021-00683-3] [Citation(s) in RCA: 128] [Impact Index Per Article: 64.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2020] [Accepted: 12/28/2020] [Indexed: 12/16/2022]
Abstract
Tethered and battery-powered devices that interface with neural tissues can restrict natural motions and prevent social interactions in animal models, thereby limiting the utility of these devices in behavioural neuroscience research. In this Review Article, we discuss recent progress in the development of miniaturized and ultralightweight devices as neuroengineering platforms that are wireless, battery-free and fully implantable, with capabilities that match or exceed those of wired or battery-powered alternatives. Such classes of advanced neural interfaces with optical, electrical or fluidic functionality can also combine recording and stimulation modalities for closed-loop applications in basic studies or in the practical treatment of abnormal physiological processes.
Collapse
Affiliation(s)
- Sang Min Won
- Department of Electrical and Computer Engineering, Sungkyunkwan University, Suwon, South Korea
| | - Le Cai
- Biomedical Engineering, College of Engineering, The University of Arizona, Tucson, AZ, USA
| | - Philipp Gutruf
- Biomedical Engineering, College of Engineering, The University of Arizona, Tucson, AZ, USA.
- Bio5 Institute and Neuroscience GIDP, University of Arizona, Tucson, AZ, USA.
- Department of Electrical and Computer Engineering, University of Arizona, Tucson, AZ, USA.
| | - John A Rogers
- Department of Materials Science and Engineering, Northwestern University, Evanston, IL, USA.
- Center for Bio-Integrated Electronics, Northwestern University, Evanston, IL, USA.
- Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA.
- Center for Advanced Molecular Imaging, Northwestern University, Evanston, IL, USA.
- Department of Mechanical Engineering, Northwestern University, Evanston, IL, USA.
- Department of Chemistry, Northwestern University, Evanston, IL, USA.
- Department of Neurological Surgery, Northwestern University, Evanston, IL, USA.
- Department of Electrical and Computer Engineering, Northwestern University, Evanston, IL, USA.
- Simpson Querrey Institute for BioNanotechnology, Northwestern University, Evanston, IL, USA.
| |
Collapse
|
13
|
Ghodhbane M, Menassol G, Beneventi D, Chaussy D, Dubois L, Zebda A, Belgacem MN. Flexible doctor blade-coated abiotic cathodes for implantable glucose/oxygen biofuel cells. RSC Adv 2023; 13:3877-3889. [PMID: 36756603 PMCID: PMC9890629 DOI: 10.1039/d2ra03471a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2022] [Accepted: 11/21/2022] [Indexed: 01/28/2023] Open
Abstract
Implantable devices powered by batteries have been used for sixty years. In recent devices, lithium-based batteries are the most widely used power source. However, lithium batteries have many disadvantages in terms of safety, reliability, and longevity and require regular monitoring and substitution. Implantable glucose biofuel cells (BFCs) are increasingly seen as a potential future technology for replacing lithium-based batteries because they do not require surgical replacement after 8-10 years and have a theoretically unlimited lifetime thanks to the continued recovery of glucose and oxygen present in the human body. This paper shows the fabrication of flexible implantable abiotic cathodes, based on a nitrogen/iron-doped graphene catalyst, for glucose/oxygen biofuel cell application. An ink, based on nitrogen-iron doped graphene as the abiotic catalyst and chitosan as a binder, was prepared and coated on a flexible teflonated gas diffusion layer using doctor blade coating. The characterization of the biocathode shows an open potential circuit corresponding to the potential of the abiotic catalyst and a high oxygen reduction current density of up to 66 μA cm-2 under physiological conditions. Those cathodes remain stable for up to two years with a current density loss of only 25%. The flexible abiotic electrode cytotoxicity was evaluated by cell culture experiments showing living cells' high tolerance on the biocathode surface. This work demonstrates that this abiotic catalyst can be a promising alternative for the development of implantable glucose BFCs due to its stability and its cytocompatibility.
Collapse
Affiliation(s)
- Myriam Ghodhbane
- Univ. Grenoble Alpes, CNRS, Grenoble INP, Institute of Engineering Univ. Grenoble Alpes, LGP2Grenoble 38000France,Univ. Grenoble Alpes/CNRS/INSERM/TIMC-IMAG UMR 5525Grenoble38000France
| | - Gauthier Menassol
- Univ. Grenoble Alpes/CNRS/INSERM/TIMC-IMAG UMR 5525Grenoble38000France,Univ. Grenoble Alpes, CEA, CNRS, IRIG-SyMMESGrenoble 38000France
| | - Davide Beneventi
- Univ. Grenoble Alpes, CNRS, Grenoble INP, Institute of Engineering Univ. Grenoble Alpes, LGP2Grenoble 38000France
| | - Didier Chaussy
- Univ. Grenoble Alpes, CNRS, Grenoble INP, Institute of Engineering Univ. Grenoble Alpes, LGP2Grenoble 38000France
| | - Lionel Dubois
- Univ. Grenoble Alpes, CEA, CNRS, IRIG-SyMMESGrenoble 38000France
| | - Abdelkader Zebda
- Univ. Grenoble Alpes/CNRS/INSERM/TIMC-IMAG UMR 5525Grenoble38000France
| | - Mohamed Naceur Belgacem
- Univ. Grenoble Alpes, CNRS, Grenoble INP, Institute of Engineering Univ. Grenoble Alpes, LGP2Grenoble 38000France
| |
Collapse
|
14
|
Menassol G, Dubois L, Nadolska M, Vadgama P, Martin D, Zebda A. A biocompatible iron doped graphene based cathode for an implantable glucose biofuel cell. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2022.141627] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/03/2022]
|
15
|
Plekhanova YV, Reshetilov AN. Nanomaterials for Controlled Adjustment of the Parameters of Electrochemical Biosensors and Biofuel Cells. BIOL BULL+ 2022. [DOI: 10.1134/s1062359022040124] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
16
|
Moerke C, Wolff A, Ince H, Ortak J, Öner A. New strategies for energy supply of cardiac implantable devices. Herzschrittmacherther Elektrophysiol 2022; 33:224-231. [PMID: 35377021 PMCID: PMC9177465 DOI: 10.1007/s00399-022-00852-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/25/2022] [Accepted: 03/01/2022] [Indexed: 11/04/2022]
Abstract
BACKGROUND Heart disease and atrial fibrillation are the leading causes of death worldwide. Patient morbidity and mortality associated with cardiovascular disease can be reduced by more accurate and continuous diagnostic and therapeutic tools provided by cardiovascular implantable electronic devices (CIEDs). OBJECTIVES Long-term operation of CIEDs continues to be a challenge due to limited battery life and the associated risk of device failure. To overcome this issue, new approaches for autonomous battery supply are being investigated. RESULTS Here, the state of the art in CIED power supply is presented and an overview of current strategies for autonomous power supply in the cardiovascular field is given, using the body as a sustainable energy source. Finally, future challenges and potentials as well as advanced features for CIEDs are discussed. CONCLUSION CIEDs need to fulfil more requirements for diagnostic and telemetric functions, which leads to higher energy requirements. Ongoing miniaturization and improved sensor technologies will help in the development of new devices.
Collapse
Affiliation(s)
- Caroline Moerke
- Department of Cardiology, Rostock University Medical Center, Rostock, Germany
| | - Anne Wolff
- Department of Cardiology, Rostock University Medical Center, Rostock, Germany
| | - Hüseyin Ince
- Department of Cardiology, Rostock University Medical Center, Rostock, Germany
| | - Jasmin Ortak
- Department of Cardiology, Rostock University Medical Center, Rostock, Germany
| | - Alper Öner
- Department of Cardiology, Rostock University Medical Center, Rostock, Germany.
| |
Collapse
|
17
|
Guo Y, Chen C, Feng J, Wang L, Wang J, Tang C, Sun X, Peng H. An Anti-Biofouling Flexible Fiber Biofuel Cell Working in the Brain. SMALL METHODS 2022; 6:e2200142. [PMID: 35322598 DOI: 10.1002/smtd.202200142] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/30/2022] [Revised: 03/09/2022] [Indexed: 06/14/2023]
Abstract
Biofuel cell (BFC) that transfers chemical energy into electricity is a promising candidate as an energy-harvesting device for implantable electronics. However, there still remain major challenges for implantable BFCs, including bulky and rigid device structure mismatching with soft tissues such as the brain, and the power output decreases due to the fouling process in a biological environment. Here, a flexible and anti-biofouling fiber BFC working in the brain chronically is developed. The fiber BFC is based on a carbon nanotube fiber electrode to possess small size and flexibility. A hydrophilic zwitterionic anti-biofouling polydopamine-2-methacryloyloxyethyl phosphorylcholine layer is designed on the surface of fiber BFC to resist the nonspecific protein adsorption in a complex biological environment. After implantation, the fiber BFC can achieve a stable device/tissue interface, along with a negligible immune response. The fiber BFC has first realized power generation in the mouse brain for over a month, exhibiting its promising prospect as an energy-harvesting device in vivo.
Collapse
Affiliation(s)
- Yue Guo
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai, 200438, China
| | - Chuanrui Chen
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai, 200438, China
| | - Jianyou Feng
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai, 200438, China
| | - Liyuan Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai, 200438, China
| | - Jiajia Wang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai, 200438, China
| | - Chengqiang Tang
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai, 200438, China
| | - Xuemei Sun
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai, 200438, China
| | - Huisheng Peng
- State Key Laboratory of Molecular Engineering of Polymers, Department of Macromolecular Science, and Laboratory of Advanced Materials, Fudan University, Shanghai, 200438, China
| |
Collapse
|
18
|
Zhang T, Liang H, Wang Z, Qiu C, Peng YB, Zhu X, Li J, Ge X, Xu J, Huang X, Tong J, Ou-Yang J, Yang X, Li F, Zhu B. Piezoelectric ultrasound energy-harvesting device for deep brain stimulation and analgesia applications. SCIENCE ADVANCES 2022; 8:eabk0159. [PMID: 35427156 PMCID: PMC9012468 DOI: 10.1126/sciadv.abk0159] [Citation(s) in RCA: 53] [Impact Index Per Article: 17.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/25/2021] [Accepted: 02/28/2022] [Indexed: 06/14/2023]
Abstract
Supplying wireless power is a challenging technical problem of great importance for implantable biomedical devices. Here, we introduce a novel implantable piezoelectric ultrasound energy-harvesting device based on Sm-doped Pb(Mg1/3Nb2/3)O3-PbTiO3 (Sm-PMN-PT) single crystal. The output power density of this device can reach up to 1.1 W/cm2 in vitro, which is 18 times higher than the previous record (60 mW/cm2). After being implanted in the rat brain, under 1-MHz ultrasound with a safe intensity of 212 mW/cm2, the as-developed device can produce an instantaneous effective output power of 280 μW, which can immediately activate the periaqueductal gray brain area. The rat electrophysiological experiments under anesthesia and behavioral experiments demonstrate that our wireless-powered device is well qualified for deep brain stimulation and analgesia applications. These encouraging results provide new insights into the development of implantable devices in the future.
Collapse
Affiliation(s)
- Tao Zhang
- School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Huageng Liang
- Department of Urology, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Zhen Wang
- Department of Psychology, University of Texas at Arlington, Arlington, TX 76019, USA
| | - Chaorui Qiu
- Electronic Materials Research Lab, Key Lab of Education Ministry/International Center for Dielectric Research, School of Electronic and Information Engineering, State Key Laboratory for Mechanical Behavior of Materials, Xi’an Jiaotong University, Xi’an 710049, China
| | - Yuan Bo Peng
- Department of Psychology, University of Texas at Arlington, Arlington, TX 76019, USA
| | - Xinyu Zhu
- School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Jiapu Li
- School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Xu Ge
- School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Jianbo Xu
- School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Xian Huang
- Department of Urology, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Junwei Tong
- Department of Urology, Union Hospital of Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430022, China
| | - Jun Ou-Yang
- School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Xiaofei Yang
- School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China
| | - Fei Li
- Electronic Materials Research Lab, Key Lab of Education Ministry/International Center for Dielectric Research, School of Electronic and Information Engineering, State Key Laboratory for Mechanical Behavior of Materials, Xi’an Jiaotong University, Xi’an 710049, China
| | - Benpeng Zhu
- School of Optical and Electronic Information, Huazhong University of Science and Technology, Wuhan 430074, China
| |
Collapse
|
19
|
Serag E, El-Maghraby A, El Nemr A. Recent developments in the application of carbon-based nanomaterials in implantable and wearable enzyme-biofuel cells. CARBON LETTERS 2022; 32:395-412. [DOI: 10.1007/s42823-021-00299-2] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2021] [Revised: 10/15/2021] [Accepted: 10/20/2021] [Indexed: 01/12/2025]
|
20
|
da Silva RTP, Ribeiro de Barros H, Sandrini DMF, Córdoba de Torresi SI. Stimuli-Responsive Regulation of Biocatalysis through Metallic Nanoparticle Interaction. Bioconjug Chem 2022; 33:53-66. [PMID: 34914373 DOI: 10.1021/acs.bioconjchem.1c00515] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Abstract
The remote control of biocatalytic processes in an extracellular medium is an exciting idea to deliver innovative solutions in the biocatalysis field. With this purpose, metallic nanoparticles (NPs) are great candidates, as their inherent thermal, electric, magnetic, and plasmonic properties can readily be manipulated upon external stimuli. Exploring the unique NP properties beyond an anchoring platform for enzymes brings up the opportunity to extend the efficiency of biocatalysts and modulate their activity through triggered events. In this review, we discuss a set of external stimuli, such as light, electricity, magnetism, and temperature, as tools for the regulation of nanobiocatalysis, including the challenges and perspectives regarding their use. In addition, we elaborate on the use of combined stimuli that create a more refined framework in terms of a multiresponsive system. Finally, we envision this review might instigate researchers in this field of study with a set of promising opportunities in the near future.
Collapse
Affiliation(s)
- Rafael T P da Silva
- Instituto de Química, Universidade de São Paulo, São Paulo (SP), 05508-000, Brazil
| | | | | | | |
Collapse
|
21
|
Yang SY, Sencadas V, You SS, Jia NZX, Srinivasan SS, Huang HW, Ahmed AE, Liang JY, Traverso G. Powering Implantable and Ingestible Electronics. ADVANCED FUNCTIONAL MATERIALS 2021; 31:2009289. [PMID: 34720792 PMCID: PMC8553224 DOI: 10.1002/adfm.202009289] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Indexed: 05/28/2023]
Abstract
Implantable and ingestible biomedical electronic devices can be useful tools for detecting physiological and pathophysiological signals, and providing treatments that cannot be done externally. However, one major challenge in the development of these devices is the limited lifetime of their power sources. The state-of-the-art of powering technologies for implantable and ingestible electronics is reviewed here. The structure and power requirements of implantable and ingestible biomedical electronics are described to guide the development of powering technologies. These powering technologies include novel batteries that can be used as both power sources and for energy storage, devices that can harvest energy from the human body, and devices that can receive and operate with energy transferred from exogenous sources. Furthermore, potential sources of mechanical, chemical, and electromagnetic energy present around common target locations of implantable and ingestible electronics are thoroughly analyzed; energy harvesting and transfer methods befitting each energy source are also discussed. Developing power sources that are safe, compact, and have high volumetric energy densities is essential for realizing long-term in-body biomedical electronics and for enabling a new era of personalized healthcare.
Collapse
Affiliation(s)
- So-Yoon Yang
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Vitor Sencadas
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; School of Mechanical, Materials & Mechatronics Engineering, University of Wollongong, Wollongong, NSW 2522, Australia
| | - Siheng Sean You
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Neil Zi-Xun Jia
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA
| | - Shriya Sruthi Srinivasan
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Hen-Wei Huang
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Abdelsalam Elrefaey Ahmed
- Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Jia Ying Liang
- Koch Institute for Integrative Cancer Research, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| | - Giovanni Traverso
- Department of Mechanical Engineering, Massachusetts Institute of Technology, Cambridge, MA 02139, USA; Division of Gastroenterology, Hepatology and Endoscopy, Department of Medicine, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA
| |
Collapse
|
22
|
Turner BL, Senevirathne S, Kilgour K, McArt D, Biggs M, Menegatti S, Daniele MA. Ultrasound-Powered Implants: A Critical Review of Piezoelectric Material Selection and Applications. Adv Healthc Mater 2021; 10:e2100986. [PMID: 34235886 DOI: 10.1002/adhm.202100986] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2021] [Revised: 06/15/2021] [Indexed: 12/14/2022]
Abstract
Ultrasound-powered implants (UPIs) represent cutting edge power sources for implantable medical devices (IMDs), as their powering strategy allows for extended functional lifetime, decreased size, increased implant depth, and improved biocompatibility. IMDs are limited by their reliance on batteries. While batteries proved a stable power supply, batteries feature relatively large sizes, limited life spans, and toxic material compositions. Accordingly, energy harvesting and wireless power transfer (WPT) strategies are attracting increasing attention by researchers as alternative reliable power sources. Piezoelectric energy scavenging has shown promise for low power applications. However, energy scavenging devices need be located near sources of movement, and the power stream may suffer from occasional interruptions. WPT overcomes such challenges by more stable, on-demand power to IMDs. Among the various forms of WPT, ultrasound powering offers distinct advantages such as low tissue-mediated attenuation, a higher approved safe dose (720 mW cm-2 ), and improved efficiency at smaller device sizes. This study presents and discusses the state-of-the-art in UPIs by reviewing piezoelectric materials and harvesting devices including lead-based inorganic, lead-free inorganic, and organic polymers. A comparative discussion is also presented of the functional material properties, architecture, and performance metrics, together with an overview of the applications where UPIs are being deployed.
Collapse
Affiliation(s)
- Brendan L. Turner
- Joint Department of Biomedical Engineering North Carolina State University and University of North Carolina Chapel Hill, 911 Oval Dr. Raleigh NC 27695 USA
| | - Seedevi Senevirathne
- The Patrick G Johnston Centre for Cancer Research Queen's University 97 Lisburn Rd Belfast BT9 7AE UK
| | - Katie Kilgour
- Department of Chemical and Biomolecular Engineering North Carolina State University Raleigh NC 27695 USA
| | - Darragh McArt
- The Patrick G Johnston Centre for Cancer Research Queen's University 97 Lisburn Rd Belfast BT9 7AE UK
| | - Manus Biggs
- Centre for Research in Medical Devices National University of Ireland Newcastle Road Galway H91 W2TY Ireland
| | - Stefano Menegatti
- Department of Chemical and Biomolecular Engineering North Carolina State University Raleigh NC 27695 USA
| | - Michael A. Daniele
- Joint Department of Biomedical Engineering North Carolina State University and University of North Carolina Chapel Hill, 911 Oval Dr. Raleigh NC 27695 USA
- Department of Electrical and Computer Engineering North Carolina State University 890 Oval Dr. Raleigh NC 27695 USA
| |
Collapse
|
23
|
Kim KK, Choi J, Ko SH. Energy Harvesting Untethered Soft Electronic Devices. Adv Healthc Mater 2021; 10:e2002286. [PMID: 33929767 DOI: 10.1002/adhm.202002286] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 04/11/2021] [Indexed: 12/24/2022]
Abstract
Advances in wearable and stretchable electronic technologies have yielded a wide range of electronic devices that can be conformably worn by, or implanted in humans to measure physiological signals. Moreover, various cutting-edge technologies for battery-free electronic devices have led to advances in healthcare devices that can continuously measure long-term biosignals for advanced human-machine interface and clinical diagnostics. This report presents the recent progress in battery-less, wearable devices using a wide range of energy harvesting sources, such as electromagnetic energy, mechanical energy, and biofuels. Additionally, this report also discusses the principles and working mechanisms of near/far-field communications, triboelectric, thermoelectric, and biofuel technologies.
Collapse
Affiliation(s)
- Kyun Kyu Kim
- Applied Nano and Thermal Science Lab Department of Mechanical Engineering Seoul National University 1 Gwanak‐ro, Gwanak‐gu Seoul 151‐742 Korea
| | - Joonhwa Choi
- Applied Nano and Thermal Science Lab Department of Mechanical Engineering Seoul National University 1 Gwanak‐ro, Gwanak‐gu Seoul 151‐742 Korea
| | - Seung Hwan Ko
- Applied Nano and Thermal Science Lab Department of Mechanical Engineering Seoul National University 1 Gwanak‐ro, Gwanak‐gu Seoul 151‐742 Korea
- Institute of Advanced Machines and Design Seoul National University Seoul 08826 Korea
- Institute of Engineering Research Seoul National University Seoul 08826 Korea
| |
Collapse
|
24
|
Wang L, Wu X, Su BSQ, Song R, Zhang JR, Zhu JJ. Enzymatic Biofuel Cell: Opportunities and Intrinsic Challenges in Futuristic Applications. ADVANCED ENERGY AND SUSTAINABILITY RESEARCH 2021. [DOI: 10.1002/aesr.202100031] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/16/2022]
Affiliation(s)
- Linlin Wang
- State Key Laboratory of Analytical Chemistry for Life Science and Collaborative Innovation Center of Chemistry for Life Sciences School of Chemistry and Chemical Engineering Nanjing University Nanjing 210093 China
| | - Xiaoge Wu
- Environment Science and Engineering College Yangzhou University Yangzhou 225009 China
| | - B. S. Qi‐wen Su
- State Key Laboratory of Analytical Chemistry for Life Science and Collaborative Innovation Center of Chemistry for Life Sciences School of Chemistry and Chemical Engineering Nanjing University Nanjing 210093 China
| | - Rongbin Song
- State Key Laboratory of Analytical Chemistry for Life Science and Collaborative Innovation Center of Chemistry for Life Sciences School of Chemistry and Chemical Engineering Nanjing University Nanjing 210093 China
| | - Jian-Rong Zhang
- State Key Laboratory of Analytical Chemistry for Life Science and Collaborative Innovation Center of Chemistry for Life Sciences School of Chemistry and Chemical Engineering Nanjing University Nanjing 210093 China
| | - Jun-Jie Zhu
- State Key Laboratory of Analytical Chemistry for Life Science and Collaborative Innovation Center of Chemistry for Life Sciences School of Chemistry and Chemical Engineering Nanjing University Nanjing 210093 China
| |
Collapse
|
25
|
Wu Z, Li Z, Li G, Zheng X, Su Y, Yang Y, Liao Y, Hu Z. DNA derived N-doped 3D conductive network with enhanced electrocatalytic activity and stability for membrane-less biofuel cells. Anal Chim Acta 2021; 1165:338546. [PMID: 33975693 DOI: 10.1016/j.aca.2021.338546] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2021] [Revised: 03/30/2021] [Accepted: 04/19/2021] [Indexed: 11/15/2022]
Abstract
Enzymes are promising electrocatalysts in many biological processes. We proposed two strategies, co-immobilization and three-dimensional (3D) space design, to strengthen electron transfer (ET). In this research, DNA base and CNT were mixed in an aqueous solution; then the mixture was dried and ground. Finally, the powder was annealed in N2 to obtain DNA derived N-doped 3D conductive network (N-G@CNT). N-G@CNT immobilized mediators on itself through adsorption. Such 3D space structure shows high activity toward a set of critical electrochemical reactions and high-performance in enzymatic biofuel cells (EBFCs). It is found that N-G@CNT conductive network possesses an interconnected porous structure and well-developed porosity. As a result, the membrane-less EBFCs equipped with enzyme/mediator co-immobilization N-G@CNT bioelectrodes were measured in a model 5 mM glucose-containing aqueous solution, human serum, and rabbit whole blood, respectively, which can generate 0.34, 0.078, and 0.15 mW cm-2 power density, respectively. The constant-current discharge method carried out in a model 5 mM glucose-containing aqueous solution shows that the discharge time reached 19 h at a discharge current density of 0.01 mA cm-2. The membrane EBFCs can deliver a high open circuit voltage of 0.68 V, a short-circuit current density of 2 mA cm-2, and a maximum power density of 0.5 mW cm-2.
Collapse
Affiliation(s)
- Zhongdong Wu
- College of Materials Science and Engineering, Central South University of Forestry and Technology, Changsha, 410004, PR China; Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Zihan Li
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China
| | - Gangyong Li
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China; State Key Laboratory of Advanced Metallurgy, University of Science and Technology Beijing, Beijing, 100083, PR China
| | - Xuchao Zheng
- State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha, Hunan, 410082, PR China
| | - Yuhe Su
- School of Life Sciences, University of Liverpool, Crown Street, Liverpool, L69 7ZB, United Kingdom
| | - Yan Yang
- College of Materials Science and Engineering, Central South University of Forestry and Technology, Changsha, 410004, PR China.
| | - Youwei Liao
- College of Materials Science and Engineering, Central South University of Forestry and Technology, Changsha, 410004, PR China.
| | - Zongqian Hu
- Beijing Institute of Radiation Medicine, Beijing, 100850, PR China.
| |
Collapse
|
26
|
Andriukonis E, Celiesiute-Germaniene R, Ramanavicius S, Viter R, Ramanavicius A. From Microorganism-Based Amperometric Biosensors towards Microbial Fuel Cells. SENSORS (BASEL, SWITZERLAND) 2021; 21:2442. [PMID: 33916302 PMCID: PMC8038125 DOI: 10.3390/s21072442] [Citation(s) in RCA: 16] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/28/2021] [Revised: 03/25/2021] [Accepted: 03/29/2021] [Indexed: 02/06/2023]
Abstract
This review focuses on the overview of microbial amperometric biosensors and microbial biofuel cells (MFC) and shows how very similar principles are applied for the design of both types of these bioelectronics-based devices. Most microorganism-based amperometric biosensors show poor specificity, but this drawback can be exploited in the design of microbial biofuel cells because this enables them to consume wider range of chemical fuels. The efficiency of the charge transfer is among the most challenging and critical issues during the development of any kind of biofuel cell. In most cases, particular redox mediators and nanomaterials are applied for the facilitation of charge transfer from applied biomaterials towards biofuel cell electrodes. Some improvements in charge transfer efficiency can be achieved by the application of conducting polymers (CPs), which can be used for the immobilization of enzymes and in some particular cases even for the facilitation of charge transfer. In this review, charge transfer pathways and mechanisms, which are suitable for the design of biosensors and in biofuel cells, are discussed. Modification methods of the cell-wall/membrane by conducting polymers in order to enhance charge transfer efficiency of microorganisms, which can be potentially applied in the design of microbial biofuel cells, are outlined. The biocompatibility-related aspects of conducting polymers with microorganisms are summarized.
Collapse
Affiliation(s)
- Eivydas Andriukonis
- NanoTechnas-Center of Nanotechnology and Material Science, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania; (E.A.); (R.C.-G.); (S.R.)
- Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania
- Laboratory of Nanotechnology, State Research Institute Center for Physical Sciences and Technology, LT-10257 Vilnius, Lithuania
| | - Raimonda Celiesiute-Germaniene
- NanoTechnas-Center of Nanotechnology and Material Science, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania; (E.A.); (R.C.-G.); (S.R.)
- Laboratory of Bioelectrics, State Research Institute Center for Physical Sciences and Technology, LT-10257 Vilnius, Lithuania
| | - Simonas Ramanavicius
- NanoTechnas-Center of Nanotechnology and Material Science, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania; (E.A.); (R.C.-G.); (S.R.)
- Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania
- Laboratory of Nanotechnology, State Research Institute Center for Physical Sciences and Technology, LT-10257 Vilnius, Lithuania
| | - Roman Viter
- NanoTechnas-Center of Nanotechnology and Material Science, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania; (E.A.); (R.C.-G.); (S.R.)
- Center for Collective Use of Scientific Equipment, Sumy State University, 40018 Sumy, Ukraine
- Institute of Atomic Physics and Spectroscopy, University of Latvia, LV-1004 Riga, Latvia
| | - Arunas Ramanavicius
- NanoTechnas-Center of Nanotechnology and Material Science, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania; (E.A.); (R.C.-G.); (S.R.)
- Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Vilnius University, LT-03225 Vilnius, Lithuania
- Laboratory of Nanotechnology, State Research Institute Center for Physical Sciences and Technology, LT-10257 Vilnius, Lithuania
| |
Collapse
|
27
|
Cai L, Gutruf P. Soft, Wireless and subdermally implantable recording and neuromodulation tools. J Neural Eng 2021; 18. [PMID: 33607646 DOI: 10.1088/1741-2552/abe805] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2020] [Accepted: 02/19/2021] [Indexed: 12/14/2022]
Abstract
Progress in understanding neuronal interaction and circuit behavior of the central and peripheral nervous system strongly relies on the advancement of tools that record and stimulate with high fidelity and specificity. Currently, devices used in exploratory research predominantly utilize cables or tethers to provide pathways for power supply, data communication, stimulus delivery and recording, which constrains the scope and use of such devices. In particular, the tethered connection, mechanical mismatch to surrounding soft tissues and bones frustrate the interface leading to irritation and limitation of motion of the subject, which in the case of fundamental and preclinical studies, impacts naturalistic behaviors of animals and precludes the use in experiments involving social interaction and ethologically relevant three-dimensional environments, limiting the use of current tools to mostly rodents and exclude species such as birds and fish. This review explores the current state-of-the-art in wireless, subdermally implantable tools that quantitively expand capabilities in analysis and perturbation of the central and peripheral nervous system by removing tethers and externalized features of implantable neuromodulation and recording tools. Specifically, the review explores power harvesting strategies, wireless communication schemes, and soft materials and mechanics that enable the creation of such devices and discuss their capabilities in the context of freely-behaving subjects. Highlights of this class of devices includes wireless battery-free and fully implantable operation with capabilities in cell specific recording, multimodal neural stimulation and electrical, optogenetic and pharmacological neuromodulation capabilities. We conclude with discussion on translation of such technologies which promises routes towards broad dissemination.
Collapse
Affiliation(s)
- Le Cai
- Biomedical Engineering, University of Arizona, 1230 N Cherry Ave., Tucson, Arizona, 85719, UNITED STATES
| | - Philipp Gutruf
- Biomedical Engineering, University of Arizona, 1230 N Cherry Ave., Tucson, Arizona, 85719, UNITED STATES
| |
Collapse
|
28
|
Ramanavicius S, Ramanavicius A. Charge Transfer and Biocompatibility Aspects in Conducting Polymer-Based Enzymatic Biosensors and Biofuel Cells. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:371. [PMID: 33540587 PMCID: PMC7912793 DOI: 10.3390/nano11020371] [Citation(s) in RCA: 74] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/31/2020] [Revised: 01/23/2021] [Accepted: 01/24/2021] [Indexed: 02/06/2023]
Abstract
Charge transfer (CT) is a very important issue in the design of biosensors and biofuel cells. Some nanomaterials can be applied to facilitate the CT in these bioelectronics-based devices. In this review, we overview some CT mechanisms and/or pathways that are the most frequently established between redox enzymes and electrodes. Facilitation of indirect CT by the application of some nanomaterials is frequently applied in electrochemical enzymatic biosensors and biofuel cells. More sophisticated and still rather rarely observed is direct charge transfer (DCT), which is often addressed as direct electron transfer (DET), therefore, DCT/DET is also targeted and discussed in this review. The application of conducting polymers (CPs) for the immobilization of enzymes and facilitation of charge transfer during the design of biosensors and biofuel cells are overviewed. Significant attention is paid to various ways of synthesis and application of conducting polymers such as polyaniline, polypyrrole, polythiophene poly(3,4-ethylenedioxythiophene). Some DCT/DET mechanisms in CP-based sensors and biosensors are discussed, taking into account that not only charge transfer via electrons, but also charge transfer via holes can play a crucial role in the design of bioelectronics-based devices. Biocompatibility aspects of CPs, which provides important advantages essential for implantable bioelectronics, are discussed.
Collapse
Affiliation(s)
- Simonas Ramanavicius
- Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Institute of Chemistry, Vilnius University, Naugarduko 24, LT-03225 Vilnius, Lithuania
| | - Arunas Ramanavicius
- Department of Physical Chemistry, Faculty of Chemistry and Geosciences, Institute of Chemistry, Vilnius University, Naugarduko 24, LT-03225 Vilnius, Lithuania
| |
Collapse
|
29
|
Berezovska A, Nedellec Y, Giroud F, Gross AJ, Cosnier S. Freestanding biopellet electrodes based on carbon nanotubes and protein compression for direct and mediated bioelectrocatalysis. Electrochem commun 2021. [DOI: 10.1016/j.elecom.2020.106895] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
|
30
|
Buaki-Sogó M, García-Carmona L, Gil-Agustí M, Zubizarreta L, García-Pellicer M, Quijano-López A. Enzymatic Glucose-Based Bio-batteries: Bioenergy to Fuel Next-Generation Devices. Top Curr Chem (Cham) 2020; 378:49. [PMID: 33125588 DOI: 10.1007/s41061-020-00312-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2018] [Accepted: 10/05/2020] [Indexed: 11/26/2022]
Abstract
This article consists of a review of the main concepts and paradigms established in the field of biological fuel cells or biofuel cells. The aim is to provide an overview of the current panorama, basic concepts, and methodologies used in the field of enzymatic biofuel cells, as well as the applications of these bio-systems in flexible electronics and implantable or portable devices. Finally, the challenges needing to be addressed in the development of biofuel cells capable of supplying power to small size devices with applications in areas related to health and well-being or next-generation portable devices are analyzed. The aim of this study is to contribute to biofuel cell technology development; this is a multidisciplinary topic about which review articles related to different scientific areas, from Materials Science to technology applications, can be found. With this article, the authors intend to reach a wide readership in order to spread biofuel cell technology for different scientific profiles and boost new contributions and developments to overcome future challenges.
Collapse
Affiliation(s)
- Mireia Buaki-Sogó
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain.
| | - Laura García-Carmona
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain
| | - Mayte Gil-Agustí
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain
| | - Leire Zubizarreta
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain
| | - Marta García-Pellicer
- Instituto Tecnológico de la Energía (ITE), Avenida Juan de la Cierva, 24, 46980, Paterna, Valencia, Spain
| | - Alfredo Quijano-López
- ITE Universitat Politécnica de València, Camino de Vera s/n edificio 6C, 46022, Valencia, Spain
| |
Collapse
|
31
|
Ohayon D, Inal S. Organic Bioelectronics: From Functional Materials to Next-Generation Devices and Power Sources. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2020; 32:e2001439. [PMID: 32691880 DOI: 10.1002/adma.202001439] [Citation(s) in RCA: 52] [Impact Index Per Article: 10.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/28/2020] [Revised: 05/03/2020] [Indexed: 05/23/2023]
Abstract
Conjugated polymers (CPs) possess a unique set of features setting them apart from other materials. These properties make them ideal when interfacing the biological world electronically. Their mixed electronic and ionic conductivity can be used to detect weak biological signals, deliver charged bioactive molecules, and mechanically or electrically stimulate tissues. CPs can be functionalized with various (bio)chemical moieties and blend with other functional materials, with the aim of modulating biological responses or endow specificity toward analytes of interest. They can absorb photons and generate electronic charges that are then used to stimulate cells or produce fuels. These polymers also have catalytic properties allowing them to harvest ambient energy and, along with their high capacitances, are promising materials for next-generation power sources integrated with bioelectronic devices. In this perspective, an overview of the key properties of CPs and examination of operational mechanism of electronic devices that leverage these properties for specific applications in bioelectronics is provided. In addition to discussing the chemical structure-functionality relationships of CPs applied at the biological interface, the development of new chemistries and form factors that would bring forth next-generation sensors, actuators, and their power sources, and, hence, advances in the field of organic bioelectronics is described.
Collapse
Affiliation(s)
- David Ohayon
- Organic Bioelectronics Laboratory, Biological and Environmental Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Sahika Inal
- Organic Bioelectronics Laboratory, Biological and Environmental Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| |
Collapse
|
32
|
Lee DY, Yun JH, Park YB, Hyeon JS, Jang Y, Choi YB, Kim HH, Kang TM, Ovalle R, Baughman RH, Kim SM, Kee CW, Kim SJ. Two-Ply Carbon Nanotube Fiber-Typed Enzymatic Biofuel Cell Implanted in Mice. IEEE Trans Nanobioscience 2020; 19:333-338. [PMID: 32603292 DOI: 10.1109/tnb.2020.2995143] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Implantable devices have emerged as a promising industry. It is inevitable that these devices will require a power source to operate in vivo. Thus, to power implantable medical devices, biofuel cells (BFCs) that generate electricity using glucose without an external power supply have been considered. Although implantable BFCs have been developed for application in vivo, they are limited by their bulky electrodes and low power density. In the present study, we attempted to apply to living mice an implantable enzymatic BFC (EBFC) that was previously reported to be a high-power EBFC comprising carbon nanotube yarn electrodes. To improve their mechanical properties and for convenient implantation, the electrodes were coated with Nafion and twisted into a micro-sized, two-ply, one-body system. When the two-ply EBFC system was implanted in the abdominal cavity of mice, it provided a high-power density of 0.3 mW/cm2. The two-ply EBFC system was injected through a needle using a syringe without surgery and the inflammatory response in vivo initially induced by the injection of the EBFC system was attenuated after 7 days, indicating the biocompatibility of the system in vivo.
Collapse
|
33
|
The biocompatibility of biofuel cells operating inside the body. Biochem Soc Trans 2020; 48:867-879. [PMID: 32539103 DOI: 10.1042/bst20190618] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/03/2020] [Revised: 05/01/2020] [Accepted: 05/12/2020] [Indexed: 11/17/2022]
Abstract
In 1968 Wolfson et al. published the concept for producing energy inside the body using catalytic electrodes exposed to the body fluid as an electrolyte and utilising naturally occurring fuels such as glucose. Since then, the technology has advanced to enhance the levels of power using enzymes immobilised within three-dimensional bioelectrodes that are nanostructured. Current research in the field of enzymatic fuel cells is directed toward applying electrochemical and nanostructural expertise to increase the energy density, to increase the power density, to increase the operational stability, and to increase the voltage output. Nonetheless, biocompatibility remains the major challenge for increasing the life-time for implanted enzymatic biofuel cells. Here, we discuss the current issues for biocompatibility and suggest directions to enhance the design of biofuel cells so as to increase the life-time of implantation whilst maintaining sufficient performance to provide power for implanted medical devices.
Collapse
|
34
|
Challenges for the Implantation of Symbiotic Nanostructured Medical Devices. APPLIED SCIENCES-BASEL 2020. [DOI: 10.3390/app10082923] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/09/2023]
Abstract
We discuss the perspectives of designing implantable medical devices that have the criterion of being symbiotic. Our starting point was whether the implanted device is intended to have any two-way (“duplex”) communication of energy or materials with the body. Such duplex communication extends the existing concepts of a biomaterial and biocompatibility to include the notion that it is important to consider the intended functional use of the implanted medical device. This demands a biomimetic approach to design functional symbiotic implantable medical devices that can be more efficient in mimicking what is happening at the molecular and cellular levels to create stable interfaces that allow for the unfettered exchanges of molecules between an implanted device and a body. Such a duplex level of communication is considered to be a necessary characteristic of symbiotic implanted medical devices that are designed to function for long periods of time inside the body to restore and assist the function of the body. We illustrate these perspectives with experience gained from implanting functional enzymatic biofuel cells.
Collapse
|
35
|
Tang J, Yan X, Engelbrekt C, Ulstrup J, Magner E, Xiao X, Zhang J. Development of graphene-based enzymatic biofuel cells: A minireview. Bioelectrochemistry 2020; 134:107537. [PMID: 32361268 DOI: 10.1016/j.bioelechem.2020.107537] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/14/2020] [Revised: 04/15/2020] [Accepted: 04/15/2020] [Indexed: 12/24/2022]
Abstract
Enzymatic biofuel cells (EBFCs) have attracted increasing attention due to their potential to harvest energy from a wide range of fuels under mild conditions. Fabrication of effective bioelectrodes is essential for the practical application of EBFCs. Graphene possesses unique physiochemical properties making it an attractive material for the construction of EBFCs. Despite these promising properties, graphene has not been used for EBFCs as frequently as carbon nanotubes, another nanoscale carbon allotrope. This review focuses on current research progress in graphene-based electrodes, including electrodes modified with graphene derivatives and graphene composites, as well as free-standing graphene electrodes. Particular features of graphene-based electrodes such as high conductivity, mechanical flexibility and high porosity for bioelectrochemical applications are highlighted. Reports on graphene-based EBFCs from the last five years are summarized, and perspectives for graphene-based EBFCs are offered.
Collapse
Affiliation(s)
- Jing Tang
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark
| | - Xiaomei Yan
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark
| | - Christian Engelbrekt
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark
| | - Jens Ulstrup
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark; Kazan National Research Technological University, K. Marx Str., 68, 420015 Kazan, Republic of Tatarstan, Russian Federation
| | - Edmond Magner
- Department of Chemical Sciences and Bernal Institute, University of Limerick, Limerick V94 T9PX, Ireland
| | - Xinxin Xiao
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark.
| | - Jingdong Zhang
- Department of Chemistry, Technical University of Denmark, Kongens Lyngby 2800, Denmark.
| |
Collapse
|
36
|
Conghaile PÓ, Kumar R, Ferrer ML, Leech D. Glucose oxidation by enzyme electrodes using genipin to crosslink chitosan, glucose oxidase and amine-containing osmium redox complexes. Electrochem commun 2020. [DOI: 10.1016/j.elecom.2020.106703] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022] Open
|
37
|
Jang Y, Kim SM, Kim KJ, Sim HJ, Kim BJ, Park JW, Baughman RH, Ruhparwar A, Kim SJ. Self-Powered Coiled Carbon-Nanotube Yarn Sensor for Gastric Electronics. ACS Sens 2019; 4:2893-2899. [PMID: 31525897 DOI: 10.1021/acssensors.9b01180] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
The strong peristaltic contraction of the stomach facilitates mixing and emptying of ingested food, which occurs rhythmically at approximately 3 cycles/min (cpm) in humans. Generally, most patients with gastroparesis show gastric electrical dysrhythmia that is disrupted electrical signals controlling gastric contractions. For treatment of gastric electrical dysrhythmia, in vivo electrical impulses to the stomach via an implanted gastric stimulator have been known to restore these gastric deformations. Nevertheless, improved sensors to monitor gastric contractions are still needed in current gastric stimulators. Recently, we have developed a new technology converting mechanical motion to electrical energy by using stretch-induced capacitance changes of a coiled carbon-nanotube (CNT) yarn. For its potential use as a gastric deformation sensor, the performance of a coiled CNT yarn was evaluated in several biological fluids. For a sinusoidal stretch to 30%, the peak-to-peak open-circuit voltage (OCV) was consistently generated at frequencies below 0.1 Hz. This sinusoidal variation in OCV augmented as the strain increased from 10 to 30%. In an in vitro artificial gastric system, the OCV was approximately linearly proportional to the balloon volume, which can monitor periodic deformations of the balloon at 2, 3, and 4 cpm as shown for human gastric deformations. Moreover, stretchy coiled yarns generate the peak electrical voltage and power when deformed. The present study shows that a self-powered CNT yarn sensor can not only monitor the changes in frequency and amplitude of volumetric change but also generate electrical power by periodic deformations of the balloon. Therefore, it seems possible to automatically deliver accurate electrical impulses according to real-time evaluation of a patient's gastric deformation based on information on the frequency, amplitude, and rate of the OCV from CNT yarn.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Ray H. Baughman
- Alan G. MacDiarmid NanoTech Institute, University of Texas at Dallas, Richardson, Texas 75083, United States
| | - Arjang Ruhparwar
- Department of Cardiac Surgery, Heart Center, University Hospital Heidelberg, Heidelberg 69120, Germany
| | | |
Collapse
|
38
|
Challenges and Opportunities of Carbon Nanomaterials for Biofuel Cells and Supercapacitors: Personalized Energy for Futuristic Self-Sustainable Devices. C — JOURNAL OF CARBON RESEARCH 2019. [DOI: 10.3390/c5040062] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Various carbon allotropes are fundamental components in electrochemical energy-conversion and energy-storage devices, e.g., biofuel cells (BFCs) and supercapacitors. Recently, biodevices, particularly wearable and implantable devices, are of distinct interest in biomedical, fitness, academic, and industrial fields due to their new fascinating capabilities for personalized applications. However, all biodevices require a sustainable source of energy, bringing widespread attention to energy research. In this review, we detail the progress in BFCs and supercapacitors attributed to carbon materials. Self-powered biosensors for futuristic biomedical applications are also featured. To develop these energy devices, many challenges needed to be addressed. For this reason, there is a need to: optimize the electron transfer between the enzymatic site and electrode; enhance the power efficiency of the device in fluctuating oxygen conditions; strengthen the efficacy of enzymatic reactions at the carbon-based electrodes; increase the electrochemically accessible surface area of the porous electrode materials; and refine the flexibility of traditional devices by introducing a mechanical resiliency of electrochemical devices to withstand daily multiplexed movements. This article will also feature carbon nanomaterial research alongside opportunities to enhance energy technology and address the challenges facing the field of personalized applications. Carbon-based energy devices have proved to be sustainable and compatible energy alternatives for biodevices within the human body, serving as attractive options for further developing diverse domains, including individual biomedical applications.
Collapse
|
39
|
Bollella P, Lee I, Blaauw D, Katz E. A Microelectronic Sensor Device Powered by a Small Implantable Biofuel Cell. Chemphyschem 2019; 21:120-128. [DOI: 10.1002/cphc.201900700] [Citation(s) in RCA: 31] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2019] [Revised: 08/12/2019] [Indexed: 12/15/2022]
Affiliation(s)
- Paolo Bollella
- Department of Chemistry and Biomolecular ScienceClarkson University Potsdam NY 13699–5810 USA
| | - Inhee Lee
- Department of Electrical Engineering and Computer ScienceUniversity of Michigan Ann Arbor MI 48109 USA
| | - David Blaauw
- Department of Electrical Engineering and Computer ScienceUniversity of Michigan Ann Arbor MI 48109 USA
| | - Evgeny Katz
- Department of Chemistry and Biomolecular ScienceClarkson University Potsdam NY 13699–5810 USA
| |
Collapse
|
40
|
Xiao X, Xia HQ, Wu R, Bai L, Yan L, Magner E, Cosnier S, Lojou E, Zhu Z, Liu A. Tackling the Challenges of Enzymatic (Bio)Fuel Cells. Chem Rev 2019; 119:9509-9558. [PMID: 31243999 DOI: 10.1021/acs.chemrev.9b00115] [Citation(s) in RCA: 200] [Impact Index Per Article: 33.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
Abstract
The ever-increasing demands for clean and sustainable energy sources combined with rapid advances in biointegrated portable or implantable electronic devices have stimulated intensive research activities in enzymatic (bio)fuel cells (EFCs). The use of renewable biocatalysts, the utilization of abundant green, safe, and high energy density fuels, together with the capability of working at modest and biocompatible conditions make EFCs promising as next generation alternative power sources. However, the main challenges (low energy density, relatively low power density, poor operational stability, and limited voltage output) hinder future applications of EFCs. This review aims at exploring the underlying mechanism of EFCs and providing possible practical strategies, methodologies and insights to tackle these issues. First, this review summarizes approaches in achieving high energy densities in EFCs, particularly, employing enzyme cascades for the deep/complete oxidation of fuels. Second, strategies for increasing power densities in EFCs, including increasing enzyme activities, facilitating electron transfers, employing nanomaterials, and designing more efficient enzyme-electrode interfaces, are described. The potential of EFCs/(super)capacitor combination is discussed. Third, the review evaluates a range of strategies for improving the stability of EFCs, including the use of different enzyme immobilization approaches, tuning enzyme properties, designing protective matrixes, and using microbial surface displaying enzymes. Fourth, approaches for the improvement of the cell voltage of EFCs are highlighted. Finally, future developments and a prospective on EFCs are envisioned.
Collapse
Affiliation(s)
- Xinxin Xiao
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China.,Department of Chemical Sciences and Bernal Institute , University of Limerick , Limerick V94 T9PX , Ireland
| | - Hong-Qi Xia
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China
| | - Ranran Wu
- Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences , 32 West seventh Road, Tianjin Airport Economic Area , Tianjin 300308 , China
| | - Lu Bai
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China
| | - Lu Yan
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China
| | - Edmond Magner
- Department of Chemical Sciences and Bernal Institute , University of Limerick , Limerick V94 T9PX , Ireland
| | - Serge Cosnier
- Université Grenoble-Alpes , DCM UMR 5250, F-38000 Grenoble , France.,Département de Chimie Moléculaire , UMR CNRS, DCM UMR 5250, F-38000 Grenoble , France
| | - Elisabeth Lojou
- Aix Marseille Univ, CNRS, BIP, Bioénergétique et Ingénierie des Protéines UMR7281 , Institut de Microbiologie de la Méditerranée, IMM , FR 3479, 31, chemin Joseph Aiguier 13402 Marseille , Cedex 20 , France
| | - Zhiguang Zhu
- Tianjin Institute of Industrial Biotechnology, Chinese Academy of Sciences , 32 West seventh Road, Tianjin Airport Economic Area , Tianjin 300308 , China
| | - Aihua Liu
- Institute for Biosensing, and College of Life Sciences , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China.,College of Chemistry & Chemical Engineering , Qingdao University , 308 Ningxia Road , Qingdao 266071 , China.,School of Pharmacy, Medical College , Qingdao University , Qingdao 266021 , China
| |
Collapse
|
41
|
Romano D, Donati E, Benelli G, Stefanini C. A review on animal-robot interaction: from bio-hybrid organisms to mixed societies. BIOLOGICAL CYBERNETICS 2019; 113:201-225. [PMID: 30430234 DOI: 10.1007/s00422-018-0787-5] [Citation(s) in RCA: 81] [Impact Index Per Article: 13.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2017] [Accepted: 10/19/2018] [Indexed: 05/28/2023]
Abstract
Living organisms are far superior to state-of-the-art robots as they have evolved a wide number of capabilities that far encompass our most advanced technologies. The merging of biological and artificial world, both physically and cognitively, represents a new trend in robotics that provides promising prospects to revolutionize the paradigms of conventional bio-inspired design as well as biological research. In this review, a comprehensive definition of animal-robot interactive technologies is given. They can be at animal level, by augmenting physical or mental capabilities through an integrated technology, or at group level, in which real animals interact with robotic conspecifics. Furthermore, an overview of the current state of the art and the recent trends in this novel context is provided. Bio-hybrid organisms represent a promising research area allowing us to understand how a biological apparatus (e.g. muscular and/or neural) works, thanks to the interaction with the integrated technologies. Furthermore, by using artificial agents, it is possible to shed light on social behaviours characterizing mixed societies. The robots can be used to manipulate groups of living organisms to understand self-organization and the evolution of cooperative behaviour and communication.
Collapse
Affiliation(s)
- Donato Romano
- The BioRobotics Institute, Sant'Anna School of Advanced Studies, Viale Rinaldo Piaggio 34, 56025, Pontedera, PI, Italy.
| | - Elisa Donati
- The Institute of Neuroinformatics, University of Zurich/ETH, Winterthurerstrasse 190, 8057, Zurich, Switzerland
| | - Giovanni Benelli
- The BioRobotics Institute, Sant'Anna School of Advanced Studies, Viale Rinaldo Piaggio 34, 56025, Pontedera, PI, Italy
- Department of Agriculture, Food and Environment, University of Pisa, Via del Borghetto 80, 56124, Pisa, Italy
| | - Cesare Stefanini
- The BioRobotics Institute, Sant'Anna School of Advanced Studies, Viale Rinaldo Piaggio 34, 56025, Pontedera, PI, Italy
- HEIC Center, BME Department, Khalifa University, PO Box 127788, Abu Dhabi, UAE
| |
Collapse
|
42
|
Challenges for successful implantation of biofuel cells. Bioelectrochemistry 2018; 124:57-72. [DOI: 10.1016/j.bioelechem.2018.05.011] [Citation(s) in RCA: 121] [Impact Index Per Article: 17.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/20/2017] [Revised: 05/11/2018] [Accepted: 05/25/2018] [Indexed: 01/09/2023]
|
43
|
Hasan MQ, Kuis R, Narayanan JS, Slaughter G. Fabrication of highly effective hybrid biofuel cell based on integral colloidal platinum and bilirubin oxidase on gold support. Sci Rep 2018; 8:16351. [PMID: 30397324 PMCID: PMC6218521 DOI: 10.1038/s41598-018-34740-w] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2018] [Accepted: 10/22/2018] [Indexed: 11/09/2022] Open
Abstract
A hybrid biofuel cell (HBFC) is explored as a low-cost alternative to abiotic and enzymatic biofuel cells. Here the HBFC provides an enzymeless approach for the fabrication of the anodic electrode while employing an enzymatic approach for the fabrication of the cathodic electrode to develop energy harvesting platform to power bioelectronic devices. The anode employed 250 μm braided gold wire modified with colloidal platinum (Au-co-Pt) and bilirubin oxidase (BODx) modified gold coated Buckypaper (BP-Au-BODx) cathode. The functionalization of the gold coated multi-walled carbon nanotube (MWCNT) structures of the BP electrodes is achieved by 3-mercaptopropionic acid surface modification to possess negatively charged carboxylic groups and subsequently followed by EDC/Sulfo-NHS (1-Ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride and N-Hydroxysulfosuccinimide) crosslinking with BODx. The integration of the BODx and gold coated MWCNTs is evaluated for bioelectrocatalytic activity. The Au-co-Pt and BP-Au-BODx exhibited excellent electrocatalytic activity towards glucose oxidation with a linear dynamic range up to 20 mM glucose and molecular oxygen reduction, respectively. The HBFC demonstrated excellent performance with the largest open circuit voltages of 0.735 V and power density of 46.31 μW/cm2 in 3 mM glucose. In addition, the HBFC operating on 3 mM glucose exhibited excellent uninterrupted operational stability while continuously powering a small electronic device. These results provide great opportunities for implementing this simple but efficient HBFC to harvest the biochemical energy of target fuel(s) in diverse medical and environmental applications.
Collapse
Affiliation(s)
- Md Qumrul Hasan
- University of Maryland Baltimore County and Bioelectronics Laboratory, Department of Computer Science and Electrical Engineering, Maryland, USA
| | - Robinson Kuis
- University of Maryland Baltimore County and Bioelectronics Laboratory, Department of Computer Science and Electrical Engineering, Maryland, USA
| | - J Shankara Narayanan
- University of Maryland Baltimore County and Bioelectronics Laboratory, Department of Computer Science and Electrical Engineering, Maryland, USA
| | - Gymama Slaughter
- University of Maryland Baltimore County and Bioelectronics Laboratory, Department of Computer Science and Electrical Engineering, Maryland, USA.
| |
Collapse
|
44
|
Applications of Emerging Bioelectrochemical Technologies in Agricultural Systems: A Current Review. ENERGIES 2018. [DOI: 10.3390/en11112951] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
Abstract
Background: Bioelectrochemical systems (BESs) are emerging energy-effective and environment-friendly technologies. Different applications of BESs are able to effectively minimize wastes and treat wastewater while simultaneously recovering electricity, biohydrogen and other value-added chemicals via specific redox reactions. Although there are many studies that have greatly advanced the performance of BESs over the last decade, research and reviews on agriculture-relevant applications of BESs are very limited. Considering the increasing demand for food, energy and water due to human population expansion, novel technologies are urgently needed to promote productivity and sustainability in agriculture. Methodology: This review study is based on an extensive literature search regarding agriculture-related BES studies mainly in the last decades (i.e., 2009–2018). The databases used in this review study include Scopus, Google Scholar and Web of Science. The current and future applications of bioelectrochemical technologies in agriculture have been discussed. Findings/Conclusions: BESs have the potential to recover considerable amounts of electric power and energy chemicals from agricultural wastes and wastewater. The recovered energy can be used to reduce the energy input into agricultural systems. Other resources and value-added chemicals such as biofuels, plant nutrients and irrigation water can also be produced in BESs. In addition, BESs may replace unsustainable batteries to power remote sensors or be designed as biosensors for agricultural monitoring. The possible applications to produce food without sunlight and remediate contaminated soils using BESs have also been discussed. At the same time, agricultural wastes can also be processed into construction materials or biochar electrodes/electrocatalysts for reducing the high costs of current BESs. Future studies should evaluate the long-term performance and stability of on-farm BES applications.
Collapse
|
45
|
Alcaraz JP, Cinquin P, Martin DK. Tackling the Concept of Symbiotic Implantable Medical Devices with Nanobiotechnologies. Biotechnol J 2018; 13:e1800102. [PMID: 30367543 DOI: 10.1002/biot.201800102] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2018] [Revised: 09/17/2018] [Indexed: 12/21/2022]
Abstract
This review takes an approach to implanted medical devices that considers whether the intention of the implanted device is to have any communication of energy or materials with the body. The first part describes some specific examples of three different classes of implants, analyzed with regards to the type of signal sent to cells. Through several examples, the authors describe that a one way signaling to the body leads to encapsulation or degradation. In most cases, those phenomena do not lead to major problems. However, encapsulation or degradation are critical for new kinds of medical devices capable of duplex communication, which are defined in this review as symbiotic devices. The concept the authors propose is that implanted medical devices that need to be symbiotic with the body also need to be designed with an intended duplex communication of energy and materials with the body. This extends the definition of a biocompatible system to one that requires stable exchange of materials between the implanted device and the body. Having this novel concept in mind will guide research in a new field between medical implant and regenerative medicine to create actual symbiotic devices.
Collapse
Affiliation(s)
- Jean-Pierre Alcaraz
- Univverity Grenoble Alpes, CNRS, Grenoble INP, TIMC-IMAG, F-38000 Grenoble, France.,SyNaBi, Pavillon Taillefer, Domaine de la Merci, La Tronche 38706, Grenoble, France
| | - Philippe Cinquin
- Univverity Grenoble Alpes, CNRS, Grenoble INP, TIMC-IMAG, F-38000 Grenoble, France.,SyNaBi, Pavillon Taillefer, Domaine de la Merci, La Tronche 38706, Grenoble, France
| | - Donald K Martin
- Univverity Grenoble Alpes, CNRS, Grenoble INP, TIMC-IMAG, F-38000 Grenoble, France.,SyNaBi, Pavillon Taillefer, Domaine de la Merci, La Tronche 38706, Grenoble, France
| |
Collapse
|
46
|
Pankratov D, Shen F, Ortiz R, Toscano MD, Thormann E, Zhang J, Gorton L, Chi Q. Fuel-independent and membrane-less self-charging biosupercapacitor. Chem Commun (Camb) 2018; 54:11801-11804. [DOI: 10.1039/c8cc06688d] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/29/2023]
Abstract
A fuel-independent self-charging biosupercapacitor consisting of an enzymatic biocathode and a bioelectrode employing supercapacitive features of immobilized myoglobin is described.
Collapse
Affiliation(s)
- Dmitry Pankratov
- Department of Chemistry
- Technical University of Denmark
- DK-2800 Kongens Lyngby
- Denmark
| | - Fei Shen
- Department of Chemistry
- Technical University of Denmark
- DK-2800 Kongens Lyngby
- Denmark
| | - Roberto Ortiz
- Department of Chemistry
- Technical University of Denmark
- DK-2800 Kongens Lyngby
- Denmark
| | | | - Esben Thormann
- Department of Chemistry
- Technical University of Denmark
- DK-2800 Kongens Lyngby
- Denmark
| | - Jingdong Zhang
- Department of Chemistry
- Technical University of Denmark
- DK-2800 Kongens Lyngby
- Denmark
| | - Lo Gorton
- Department of Biochemistry and Structural Biology
- Lund University
- SE-22100 Lund
- Sweden
| | - Qijin Chi
- Department of Chemistry
- Technical University of Denmark
- DK-2800 Kongens Lyngby
- Denmark
| |
Collapse
|