1
|
Labordère AL, Ruzickova P, Kamus LJ, Beauchamp G, Malo A, Richard H, Laverty S. Vascularity evaluation of the equine tarsocrural and proximal intertarsal joint septum, and comparative analysis of two arthroscopic transection techniques. Vet Surg 2024. [PMID: 38804260 DOI: 10.1111/vsu.14106] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2023] [Revised: 03/26/2024] [Accepted: 04/26/2024] [Indexed: 05/29/2024]
Abstract
OBJECTIVE To evaluate vascularity of the synovial membrane covered septum (SMS) separating the tarsocrural (TC) and proximal intertarsal (PIT) joints (Part 1) and compare two methods of transection, electrosurgical or Ferris Smith rongeur (FS rongeur) (Part 2). STUDY DESIGN Experimental study. SAMPLE POPULATION Part 1, 10 SMS (n = 5 horses). Part 2, six horses (n = 12 tarsi). METHODS In part 1, SMS harvested postmortem were each divided into eight regions of interest (ROIs), processed for histology, and immunostained with anti-α-actin antibody for blood vessel identification. Vascular density was calculated for each ROI. Data was compared within and between horses. In part 2, six horses underwent TC arthroscopy. Each limb was randomly assigned to undergo either electrosurgical or FS rongeur SMS transection. SMS transection and total operative time were recorded. Intraoperative hemorrhage was scored. Data was compared between both techniques. RESULTS Significant interindividual variations in SMS vascular density were detected (p = .02), but there were no differences among ROIs. No differences in the transection time were detected between electrosurgery (4.83 ± 0.54 min) and FS rongeur (4.33 ± 0.67 min). No differences were found in intraoperative hemorrhage scores between techniques. CONCLUSION Vascularity within the SMS varies among horses but not within its regions. Electrosurgical or FS rongeur transection of the medial SMS during tarsocrural arthroscopy is a rapid technique and improves surgical access to the dorsal compartment of the PIT.
Collapse
Affiliation(s)
- Alexandra L Labordère
- Comparative Orthopedic Research Laboratory, Department of Clinical Sciences, Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Quebec, Canada
| | - Pavlina Ruzickova
- Comparative Orthopedic Research Laboratory, Department of Clinical Sciences, Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Quebec, Canada
| | - Louis J Kamus
- Comparative Orthopedic Research Laboratory, Department of Clinical Sciences, Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Quebec, Canada
| | - Guy Beauchamp
- Comparative Orthopedic Research Laboratory, Department of Clinical Sciences, Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Quebec, Canada
| | - Alexia Malo
- Comparative Orthopedic Research Laboratory, Department of Clinical Sciences, Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Quebec, Canada
| | - Hélène Richard
- Comparative Orthopedic Research Laboratory, Department of Clinical Sciences, Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Quebec, Canada
| | - Sheila Laverty
- Comparative Orthopedic Research Laboratory, Department of Clinical Sciences, Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, Quebec, Canada
| |
Collapse
|
2
|
Guergan S, Boeer B, Fugunt R, Helms G, Roehm C, Solomianik A, Neugebauer A, Nuessle D, Schuermann M, Brunecker K, Jurjut O, Boehme KA, Dammeier S, Enderle MD, Bettio S, Gonzalez-Menendez I, Staebler A, Brucker SY, Kraemer B, Wallwiener D, Fend F, Hahn M. Optical Emission Spectroscopy for the Real-Time Identification of Malignant Breast Tissue. Diagnostics (Basel) 2024; 14:338. [PMID: 38337854 PMCID: PMC10855719 DOI: 10.3390/diagnostics14030338] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/03/2023] [Revised: 01/29/2024] [Accepted: 01/31/2024] [Indexed: 02/12/2024] Open
Abstract
Breast conserving resection with free margins is the gold standard treatment for early breast cancer recommended by guidelines worldwide. Therefore, reliable discrimination between normal and malignant tissue at the resection margins is essential. In this study, normal and abnormal tissue samples from breast cancer patients were characterized ex vivo by optical emission spectroscopy (OES) based on ionized atoms and molecules generated during electrosurgical treatment. The aim of the study was to determine spectroscopic features which are typical for healthy and neoplastic breast tissue allowing for future real-time tissue differentiation and margin assessment during breast cancer surgery. A total of 972 spectra generated by electrosurgical sparking on normal and abnormal tissue were used for support vector classifier (SVC) training. Specific spectroscopic features were selected for the classification of tissues in the included breast cancer patients. The average classification accuracy for all patients was 96.9%. Normal and abnormal breast tissue could be differentiated with a mean sensitivity of 94.8%, a specificity of 99.0%, a positive predictive value (PPV) of 99.1% and a negative predictive value (NPV) of 96.1%. For 66.6% patients all classifications reached 100%. Based on this convincing data, a future clinical application of OES-based tissue differentiation in breast cancer surgery seems to be feasible.
Collapse
Affiliation(s)
- Selin Guergan
- Department of Women’s Health, Tuebingen University Hospital, 72076 Tübingen, Germany; (B.B.); (R.F.); (G.H.); (C.R.); (A.S.); (S.Y.B.); (B.K.); (D.W.); (M.H.)
| | - Bettina Boeer
- Department of Women’s Health, Tuebingen University Hospital, 72076 Tübingen, Germany; (B.B.); (R.F.); (G.H.); (C.R.); (A.S.); (S.Y.B.); (B.K.); (D.W.); (M.H.)
| | - Regina Fugunt
- Department of Women’s Health, Tuebingen University Hospital, 72076 Tübingen, Germany; (B.B.); (R.F.); (G.H.); (C.R.); (A.S.); (S.Y.B.); (B.K.); (D.W.); (M.H.)
| | - Gisela Helms
- Department of Women’s Health, Tuebingen University Hospital, 72076 Tübingen, Germany; (B.B.); (R.F.); (G.H.); (C.R.); (A.S.); (S.Y.B.); (B.K.); (D.W.); (M.H.)
| | - Carmen Roehm
- Department of Women’s Health, Tuebingen University Hospital, 72076 Tübingen, Germany; (B.B.); (R.F.); (G.H.); (C.R.); (A.S.); (S.Y.B.); (B.K.); (D.W.); (M.H.)
| | - Anna Solomianik
- Department of Women’s Health, Tuebingen University Hospital, 72076 Tübingen, Germany; (B.B.); (R.F.); (G.H.); (C.R.); (A.S.); (S.Y.B.); (B.K.); (D.W.); (M.H.)
| | - Alexander Neugebauer
- Erbe Elektromedizin GmbH, Waldhoernlestr. 17, 72072 Tübingen, Germany; (A.N.); (D.N.); (M.S.); (O.J.); (K.A.B.); (S.D.); (M.D.E.)
| | - Daniela Nuessle
- Erbe Elektromedizin GmbH, Waldhoernlestr. 17, 72072 Tübingen, Germany; (A.N.); (D.N.); (M.S.); (O.J.); (K.A.B.); (S.D.); (M.D.E.)
| | - Mirjam Schuermann
- Erbe Elektromedizin GmbH, Waldhoernlestr. 17, 72072 Tübingen, Germany; (A.N.); (D.N.); (M.S.); (O.J.); (K.A.B.); (S.D.); (M.D.E.)
| | - Kristin Brunecker
- Erbe Elektromedizin GmbH, Waldhoernlestr. 17, 72072 Tübingen, Germany; (A.N.); (D.N.); (M.S.); (O.J.); (K.A.B.); (S.D.); (M.D.E.)
| | - Ovidiu Jurjut
- Erbe Elektromedizin GmbH, Waldhoernlestr. 17, 72072 Tübingen, Germany; (A.N.); (D.N.); (M.S.); (O.J.); (K.A.B.); (S.D.); (M.D.E.)
| | - Karen A. Boehme
- Erbe Elektromedizin GmbH, Waldhoernlestr. 17, 72072 Tübingen, Germany; (A.N.); (D.N.); (M.S.); (O.J.); (K.A.B.); (S.D.); (M.D.E.)
| | - Sascha Dammeier
- Erbe Elektromedizin GmbH, Waldhoernlestr. 17, 72072 Tübingen, Germany; (A.N.); (D.N.); (M.S.); (O.J.); (K.A.B.); (S.D.); (M.D.E.)
| | - Markus D. Enderle
- Erbe Elektromedizin GmbH, Waldhoernlestr. 17, 72072 Tübingen, Germany; (A.N.); (D.N.); (M.S.); (O.J.); (K.A.B.); (S.D.); (M.D.E.)
| | - Sabrina Bettio
- Institute of Pathology and Neuropathology, Tuebingen University Hospital, 72076 Tübingen, Germany; (S.B.); (I.G.-M.); (A.S.); (F.F.)
| | - Irene Gonzalez-Menendez
- Institute of Pathology and Neuropathology, Tuebingen University Hospital, 72076 Tübingen, Germany; (S.B.); (I.G.-M.); (A.S.); (F.F.)
| | - Annette Staebler
- Institute of Pathology and Neuropathology, Tuebingen University Hospital, 72076 Tübingen, Germany; (S.B.); (I.G.-M.); (A.S.); (F.F.)
| | - Sara Y. Brucker
- Department of Women’s Health, Tuebingen University Hospital, 72076 Tübingen, Germany; (B.B.); (R.F.); (G.H.); (C.R.); (A.S.); (S.Y.B.); (B.K.); (D.W.); (M.H.)
| | - Bernhard Kraemer
- Department of Women’s Health, Tuebingen University Hospital, 72076 Tübingen, Germany; (B.B.); (R.F.); (G.H.); (C.R.); (A.S.); (S.Y.B.); (B.K.); (D.W.); (M.H.)
| | - Diethelm Wallwiener
- Department of Women’s Health, Tuebingen University Hospital, 72076 Tübingen, Germany; (B.B.); (R.F.); (G.H.); (C.R.); (A.S.); (S.Y.B.); (B.K.); (D.W.); (M.H.)
| | - Falko Fend
- Institute of Pathology and Neuropathology, Tuebingen University Hospital, 72076 Tübingen, Germany; (S.B.); (I.G.-M.); (A.S.); (F.F.)
| | - Markus Hahn
- Department of Women’s Health, Tuebingen University Hospital, 72076 Tübingen, Germany; (B.B.); (R.F.); (G.H.); (C.R.); (A.S.); (S.Y.B.); (B.K.); (D.W.); (M.H.)
| |
Collapse
|
3
|
Elmore L, Minissale NJ, Israel L, Katz Z, Safran J, Barba A, Austin L, Schaer TP, Freeman TA. Evaluating the Healing Potential of J-Plasma Scalpel-Created Surgical Incisions in Porcine and Rat Models. Biomedicines 2024; 12:277. [PMID: 38397879 PMCID: PMC10886613 DOI: 10.3390/biomedicines12020277] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2023] [Revised: 01/16/2024] [Accepted: 01/20/2024] [Indexed: 02/25/2024] Open
Abstract
Cold atmospheric plasma devices generate reactive oxygen and nitrogen species that can be anti-microbial but also promote cell migration, differentiation, and tissue wound healing. This report investigates the healing of surgical incisions created using cold plasma generated by the J-Plasma scalpel (Precise Open handpiece, Apyx Medical, Inc.) compared to a steel scalpel in in vivo porcine and rat models. The J-Plasma scalpel is currently FDA approved for the delivery of helium plasma to cut, coagulate, and ablate soft tissue during surgical procedures. To our knowledge, this device has not been studied in creating surgical incisions but only during deeper dissection and hemostasis. External macroscopic and histologic grading by blinded reviewers revealed no significant difference in wound healing appearance or physiology in incisions created using the plasma scalpel as compared with a steel blade scalpel. Incisions created with the plasma scalpel also had superior hemostasis and a reduction in tissue and blood carryover. Scanning electron microscopy (SEM) and histology showed collagen fibril fusion occurred as the plasma scalpel incised through the tissue, contributing to a sealing effect. In addition, when bacteria were injected into the dermis before incision, the plasma scalpel disrupted the bacterial membrane as visualized in SEM images. External macroscopic and histologic grading by blinded reviewers revealed no significant difference in wound healing appearance or physiology. Based on these results, we propose additional studies to clinically evaluate the use of cold plasma in applications requiring hemostasis or when an increased likelihood of subdermal pathogen leakage could cause surgical site infection (i.e., sites with increased hair follicles).
Collapse
Affiliation(s)
- Lilith Elmore
- Department of Orthopaedic Research, Thomas Jefferson University, Philadelphia, PA 19107, USA (J.S.)
| | | | - Lauren Israel
- Department of Orthopaedic Research, Thomas Jefferson University, Philadelphia, PA 19107, USA (J.S.)
| | - Zoe Katz
- Department of Orthopaedic Research, Thomas Jefferson University, Philadelphia, PA 19107, USA (J.S.)
| | - Jordan Safran
- Department of Orthopaedic Research, Thomas Jefferson University, Philadelphia, PA 19107, USA (J.S.)
| | - Adriana Barba
- Department of Clinical Studies, New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA 19348, USA (T.P.S.)
| | - Luke Austin
- Rothman Orthopaedic Institute, Philadelphia, PA 19107, USA
| | - Thomas P. Schaer
- Department of Clinical Studies, New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA 19348, USA (T.P.S.)
| | - Theresa A. Freeman
- Department of Orthopaedic Research, Thomas Jefferson University, Philadelphia, PA 19107, USA (J.S.)
| |
Collapse
|
4
|
Ran J, El-Kebir H, Lee Y, Chamorro LP, Berlin R, Aguiluz Cornejo GM, Benedetti E, Giulianotti PC, Bhargava R, Bentsman J, Ostoja-Starzewski M. Heat conduction in live tissue during radiofrequency electrosurgery. J R Soc Interface 2024; 21:20230420. [PMID: 38228182 PMCID: PMC10791539 DOI: 10.1098/rsif.2023.0420] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/23/2023] [Accepted: 12/11/2023] [Indexed: 01/18/2024] Open
Abstract
In this paper, we propose a method to model radiofrequency electrosurgery to capture the phenomena at higher temperatures and present the methods for parameter estimation. Experimental data taken from our surgical trials performed on in vivo porcine liver show that a non-Fourier Maxwell-Cattaneo-type model can be suitable for this application when used in combination with an Arrhenius-type model that approximates the energy dissipation in physical and chemical reactions. The resulting model structure has the advantage of higher accuracy than existing ones, while reducing the computation time required.
Collapse
Affiliation(s)
- Junren Ran
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Hamza El-Kebir
- Department of Aerospace Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Yongseok Lee
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Leonardo P. Chamorro
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Richard Berlin
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Carle Foundation Hospital, Urbana, IL, USA
| | | | - Enrico Benedetti
- Department of Surgery, University of Illinois at Chicago, Chicago, IL, USA
| | | | - Rohit Bhargava
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Joseph Bentsman
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| | - Martin Ostoja-Starzewski
- Department of Mechanical Science and Engineering, University of Illinois at Urbana-Champaign, Urbana, IL, USA
- Beckman Institute for Advanced Science and Technology, University of Illinois at Urbana-Champaign, Urbana, IL, USA
| |
Collapse
|
5
|
Yao G, Wu F, Lucas M, Zheng L, Wang C, Gu H. Effect of longitudinal-bending elliptical ultrasonic vibration assistance on electrosurgical cutting and hemostasis. ULTRASONICS 2023; 135:107113. [PMID: 37517346 DOI: 10.1016/j.ultras.2023.107113] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/08/2022] [Revised: 06/24/2023] [Accepted: 07/18/2023] [Indexed: 08/01/2023]
Abstract
Electrosurgical devices are widely used for tissue cutting and hemostasis in minimally invasive surgery (MIS) for their high precision and low trauma. However, tissue adhesion and the resulting thermal injury can cause infection and impede the wound-healing process. This paper proposes a longitudinal-bending elliptical ultrasonic vibration-assisted (EUV-A) electrosurgical cutting system that incorporates an ultrasonic vibration in the direction of the cut by introducing an elliptical motion of the surgical tip. Compared with a solely longitudinal ultrasonic vibration-assisted (UV-A) electrosurgical device, the EUV-A electrode contacts the tissue intermittently, thus allowing for a cooler cut and preventing tissue accumulation. The experimental results reveal that the EUV-A electrode demonstrates better performance than the UV-A electrode for both anti-adhesion and thermal injury through in vitro experiments in porcine samples. The tissue removal mechanism of EUV-A electrosurgical cutting is modeled to investigate its anti-adhesion effect. In addition, lower adhesion, lower temperature, and faster cutting are demonstrated through in vivo experiments in rabbit samples. Results show that the EUV-A electrode causes lower thermal injury, indicative of faster postoperative healing. Finally, efficacy of the hemostatic effect of the EUV-A electrode is demonstrated in vivo for vessels up to 3.5 mm (equivalent to that of electrocautery). The study reveals that the EUV-A electrosurgical cutting system can achieve safe tissue incision and hemostasis.
Collapse
Affiliation(s)
- Guang Yao
- Guangdong Provincial Key Laboratory of Minimally Invasive Surgical Instruments and Manufacturing Technology, Guangdong University of Technology, Guangzhou 510006, China
| | - Fei Wu
- Guangdong Provincial Key Laboratory of Minimally Invasive Surgical Instruments and Manufacturing Technology, Guangdong University of Technology, Guangzhou 510006, China
| | - Margaret Lucas
- James Watt School of Engineering, University of Glasgow, Glasgow G12 8QQ, UK
| | - Lijuan Zheng
- Guangdong Provincial Key Laboratory of Minimally Invasive Surgical Instruments and Manufacturing Technology, Guangdong University of Technology, Guangzhou 510006, China
| | - Chengyong Wang
- Guangdong Provincial Key Laboratory of Minimally Invasive Surgical Instruments and Manufacturing Technology, Guangdong University of Technology, Guangzhou 510006, China.
| | - Heng Gu
- Guangdong Institute of Medical Instruments, Guangzhou 510500, China
| |
Collapse
|
6
|
Iwai S, Kobayashi S, Torai S, Kobayashi E. Development and application of a spray tip that enables electrocoagulation of a variety of tissues. Heliyon 2023; 9:e17771. [PMID: 37560677 PMCID: PMC10407041 DOI: 10.1016/j.heliyon.2023.e17771] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2022] [Revised: 06/26/2023] [Accepted: 06/27/2023] [Indexed: 08/11/2023] Open
Abstract
BACKGROUND Spray hemostasis is possible using a high-frequency power source from the tip of an electric scalpel; however, the difficulties regarding the uniformity and rapidity of the hemostasis surface remain. This study reports the development of a novel electrocoagulation device tip that can be used in endoscopic and robotic surgeries and can quickly coagulate and hemostat and easily adjust the extent of cauterization and hemostasis while minimizing the depth of thermal injury. METHODS The safety and efficacy of the hemostatic device were verified in a porcine model. A liver surface transection was conducted in vivo and the rapidity of the hemostatic effect of the device was observed. An extracted stomach, kidney, and liver were cauterized ex vivo by three operators with different surgical skills and the effects were analyzed pathologically. In addition, a sacrificed pig cadaver was used to achieve hemostasis at a renal transection site using the multi-spray endoscope tip. RESULTS An increase in the number of tip terminals expanded the cauterization surface and shortened the cauterization time. In parenchymatous organs, uniform cauterization was possible without increasing the depth of thermal injury. The cauterization depth did not depend on the operator's skill, and the spray coagulation was safe. The variable spray tip allowed for simple hemostasis during open and laparoscopic surgeries. CONCLUSIONS This novel electrocoagulation device tip can be developed as a forceps that can change the spray range and can be used during laparoscopic and robotic surgeries.
Collapse
Affiliation(s)
- Satomi Iwai
- Kitasato University School of Veterinary Medicine, Endowed Chair for the Promotion of Minipig Research, 35-1, Higashi 23, Towada City, Aomori, 034-8628, Japan
| | - Shou Kobayashi
- Kobayashi Regenerative Research Institute, LLC, 1 Chayanochou, Wakayama-shi, Wakayama-ken, 640-8263, Japan
| | - Shinji Torai
- Department of Kidney Regenerative Medicine, Industry-Academia Collaborative Department, The Jikei University School of Medicine, 3-25-8 Nishi-Shimbashi, Minato-ku, Tokyo, 105-8461, Japan
| | - Eiji Kobayashi
- Kitasato University School of Veterinary Medicine, Endowed Chair for the Promotion of Minipig Research, 35-1, Higashi 23, Towada City, Aomori, 034-8628, Japan
- Kobayashi Regenerative Research Institute, LLC, 1 Chayanochou, Wakayama-shi, Wakayama-ken, 640-8263, Japan
- Department of Kidney Regenerative Medicine, Industry-Academia Collaborative Department, The Jikei University School of Medicine, 3-25-8 Nishi-Shimbashi, Minato-ku, Tokyo, 105-8461, Japan
| |
Collapse
|
7
|
Comparison of Efficacy and Inflammatory Response to Thermoconjunctivoplasty Performed with Cautery or Pulsed 1460 nm Laser. Int J Mol Sci 2023; 24:ijms24065740. [PMID: 36982810 PMCID: PMC10053331 DOI: 10.3390/ijms24065740] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2023] [Revised: 03/12/2023] [Accepted: 03/15/2023] [Indexed: 03/19/2023] Open
Abstract
Conjunctivochalasis is a degenerative condition of the conjunctiva that disrupts tear distribution and causes irritation. Thermoreduction of the redundant conjunctiva is required if symptoms are not relieved with medical therapy. Near-infrared laser treatment is a more controlled method to shrink the conjunctiva than thermocautery. This study compared tissue shrinkage, histology, and postoperative inflammation in thermoconjunctivoplasty performed on the mouse conjunctiva using either thermocautery or pulsed 1460 nm near-infrared laser irradiation. Three sets of experiments were performed on female C57BL/6J mice (n = 72, 26 per treatment group and 20 control) to assess conjunctival shrinkage, wound histology, and inflammation 3 and 10 days after treatment. Both treatments effectively shrunk the conjunctiva, but thermocautery caused greater epithelial damage. Thermocautery caused greater infiltration of neutrophils on day 3 and neutrophils and CD11b+ myeloid cells on day 10. The thermocautery group had significantly higher conjunctival expression of IL-1β on day 3. Expression of chemokine CCL2 was higher in the conjunctiva on day 3 and tear concentrations were higher on day 7 in the laser group. These results suggest that pulsed laser treatment causes less tissue damage and postoperative inflammation than thermocautery while effectively addressing conjunctivochalasis.
Collapse
|
8
|
Scarano A, Di Giulio R, Gehrke SA, Tagariello G, Romano F, Lorusso F. Atmospheric Plasma Lingual Frenectomy Followed by Post Operative Tongue Exercises: A Case Series. CHILDREN (BASEL, SWITZERLAND) 2023; 10:children10010105. [PMID: 36670655 PMCID: PMC9857210 DOI: 10.3390/children10010105] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/21/2022] [Revised: 12/23/2022] [Accepted: 12/27/2022] [Indexed: 01/06/2023]
Abstract
The lingual frenulum is a submucosal component significantly involved in the mobility of the tongue. In the case of short lingual frenulum, different surgical approaches have been proposed. Atmospheric plasma is a thermal technique of vaporization or sublimation of the superficial tissues, without going deep, and the resulting fine carbonized layer avoids bleeding. The aim of the present investigation was to evaluate the effectiveness of atmospheric plasma (voltaic arc dermabrasion) for the frenectomy of a short lingual frenulum. A total of 30 patients with an age range between 6−11 years old and a class III/IV Kotlow’s ankyloglossia classification were included in the study. The Kotlow’s free-tongue, maximal interincisal mouth opening (MIO, mm) and interincisal mouth opening with tongue tip to maxillary incisive papillae at roof of mouth (MOTTIP, mm) were calculated at the baseline, immediately postoperatively (T0), at one week (T1), one month (T2) and two months (T3). A significant increase of Kotlow’s measurements, MOTTIP and MIO were detected when comparing the baseline and the T0 (p < 0.05). No significant difference was detected between the T0, T1 and T2 (p > 0.05). The atmospheric plasma demonstrated a very minimal invasive approach for frenectomy, without important or fibrotic complications and with very low recurrence rates.
Collapse
Affiliation(s)
- Antonio Scarano
- Department of Innovative Technologies in Medicine and Dentistry, University of Chieti–Pescara, 66100 Chieti, Italy
- Correspondence: ; Tel.: +39-08713554084; Fax: +39-08713554099
| | - Rosanna Di Giulio
- Department of Innovative Technologies in Medicine and Dentistry, University of Chieti–Pescara, 66100 Chieti, Italy
| | | | | | | | - Felice Lorusso
- Department of Innovative Technologies in Medicine and Dentistry, University of Chieti–Pescara, 66100 Chieti, Italy
| |
Collapse
|
9
|
Villamarín-Bello NM, Rodríguez AG, Torre EDRDL, Fonseca E. Electrosurgical epilation using acupuncture needles for unwanted white hairs after surgery. J Am Acad Dermatol 2022; 87:e215-e216. [PMID: 35551959 DOI: 10.1016/j.jaad.2022.05.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2022] [Revised: 04/27/2022] [Accepted: 05/03/2022] [Indexed: 11/29/2022]
Affiliation(s)
| | - Alba González Rodríguez
- Department of Plastic and Reconstructive Surgery, University Hospital of A Coruña, A Coruña, Spain
| | | | - Eduardo Fonseca
- Department of Dermatology, University Hospital of A Coruña, A Coruña, Spain
| |
Collapse
|
10
|
Tissue-Welding Device: Considerable Advantages for Spleen Surgery Based on Histological and Cardiorespiratory Investigation. Vet Med Int 2022; 2022:9270966. [PMID: 36250186 PMCID: PMC9553717 DOI: 10.1155/2022/9270966] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 08/29/2022] [Accepted: 09/02/2022] [Indexed: 11/29/2022] Open
Abstract
During splenic surgery, it is important to control blood loss and the potential risk of cardiac arrhythmia. The best way to prevent complications from surgery is to use the appropriate surgical devices; however, there is no guideline for the use of specific surgical devices for spleen incision. Therefore, the aim of this research was to compare the interactions of various surgical devices with spleen tissue, their cardiorespiratory effects during incision, and subsequent spleen surgical wound healing. A total of 75 rabbits were included in the study. CO2 laser (n = 15), radiofrequency device (n = 15), electrocoagulator (n = 15), tissue-welding device (n = 15), and scalpel (n = 15) were used to make incisions in rabbits' spleens. Spleen biopsies of the incision area were taken from each animal at the day 0, 7, and 14 after surgery. Contactless thermography was performed during surgery. Suturing was not used after incision with the tissue-welding device, but incisions made by other surgical devices were sutured. The results showed that the width of spleen necrosis differed significantly between the various surgical devices used on spleen tissues. There was a positive, strong, and linear association between necrosis width and the tissue temperature of cutting edges. Significant increases in the heart rate were observed during spleen surgery performed with laser, scalpel, and radiofrequency devices. In conclusion, the tissue-welding device confers a significant advantage in spleen surgery, as there is neither a need for sutures nor a significant deviation in the heart rate.
Collapse
|
11
|
Clancy C, Dunne SS, Baban C, Tormey S, Merrigan A, O'Connell NH, Coffey JC, Dunne CP. A hypothesis for association between electrical surgical incision techniques and surgical site infection. J Hosp Infect 2022; 128:36-38. [PMID: 35853544 DOI: 10.1016/j.jhin.2022.07.012] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2022] [Revised: 07/07/2022] [Accepted: 07/08/2022] [Indexed: 11/30/2022]
Affiliation(s)
- C Clancy
- School of Medicine, University of Limerick, Limerick, Ireland
| | - S S Dunne
- School of Medicine, University of Limerick, Limerick, Ireland
| | - C Baban
- School of Medicine, University of Limerick, Limerick, Ireland; Department of Surgery, University Hospital Limerick
| | - S Tormey
- School of Medicine, University of Limerick, Limerick, Ireland; Department of Surgery, University Hospital Limerick
| | - A Merrigan
- Department of Surgery, University Hospital Limerick
| | - N H O'Connell
- School of Medicine, University of Limerick, Limerick, Ireland; Department of Clinical Microbiology, University of Limerick Hospitals Group, Limerick, Ireland; Centre for Interventions in Infection, Inflammation & Immunity (4i), University of Limerick, Limerick, Ireland
| | - J C Coffey
- School of Medicine, University of Limerick, Limerick, Ireland; Department of Surgery, University Hospital Limerick; Centre for Interventions in Infection, Inflammation & Immunity (4i), University of Limerick, Limerick, Ireland
| | - C P Dunne
- School of Medicine, University of Limerick, Limerick, Ireland; Centre for Interventions in Infection, Inflammation & Immunity (4i), University of Limerick, Limerick, Ireland.
| |
Collapse
|
12
|
Gulfan MCB, Wanitphakdeedecha R, Wongdama S, Jantanapornchai N, Yan C, Rakchart S. Efficacy and Safety of Using Noninsulated Microneedle Radiofrequency Alone Versus in Combination with Polynucleotides for the Treatment of Melasma: A Pilot Study. Dermatol Ther (Heidelb) 2022; 12:1325-1336. [PMID: 35538360 PMCID: PMC9209614 DOI: 10.1007/s13555-022-00728-8] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2022] [Accepted: 04/08/2022] [Indexed: 11/30/2022] Open
Abstract
Introduction This split-face, double-blind, randomized controlled study investigated the efficacy and safety of using a microneedling radiofrequency (RF) device with polynucleotides (PN) versus RF alone for the treatment of melasma. Methods Thirty adult participants with melasma (Fitzpatrick skin types III–V) received three treatments with an invasive, bipolar, pulsed-type microneedling RF device on both sides of the face. The treatment sessions occurred once every 2 weeks. The hemifaces of each participant were designated for treatment and control with PN and normal saline solution (NSS), applied after treatment with RF. Measurements were made of melanin index (MI), erythema index (EI), skin roughness (by the Antera 3D system), modified melasma area severity index (mMASI) for each hemiface, and patients’ self-assessed improvement. These occurred at baseline and again following the final treatment (2 weeks and 1, 2, 3, and 6 months after). Mean values were obtained for MI, EI, skin roughness, and mMASI. A generalized estimating equation (GEE) was used to compare the obtained values for the outcome measures across all assessment points. Results All patients were women (mean age, 43.2 ± 7.0 years). Mixed melasma predominated (61.5%; n = 16), and the mean duration of melasma was 8.9 ± 6.5 years. Twenty-six participants were followed up to the 6-month assessment point. Significant improvements were observed from baseline in MI, skin roughness, and mMASI scores for both the PN and control sides at 6 months, with no statistically significant differences between sides. Patients’ self-assessed improvement scores also showed a positive trend. Melasma recurrence was observed in three patients at 2, 3, and 4 months after the last treatment session (10% recurrence rate). Conclusions The combination of an invasive, bipolar, pulsed-type microneedling RF with PN is not superior compared with microneedling RF alone in the treatment of melasma. Microneedling RF may be considered as safe and efficacious for the improvement of skin roughness, and as an adjunctive treatment option for melasma. Clinical Trial Registration This study was registered on ClinicalTrials.gov and assigned NCT number TCTR20210804002.
Collapse
Affiliation(s)
- Ma Christina B Gulfan
- Department of Dermatology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | | | - Supisara Wongdama
- Department of Dermatology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Nuttagarn Jantanapornchai
- Department of Dermatology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | - Chadakan Yan
- Department of Dermatology, Faculty of Medicine Siriraj Hospital, Mahidol University, Bangkok, Thailand
| | | |
Collapse
|
13
|
Amiri SA, Berckel PV, Lai M, Dankelman J, Hendriks BHW. Tissue-mimicking phantom materials with tunable optical properties suitable for assessment of diffuse reflectance spectroscopy during electrosurgery. BIOMEDICAL OPTICS EXPRESS 2022; 13:2616-2643. [PMID: 35774339 PMCID: PMC9203083 DOI: 10.1364/boe.449637] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/29/2021] [Revised: 02/08/2022] [Accepted: 02/09/2022] [Indexed: 06/15/2023]
Abstract
Emerging intraoperative tumor margin assessment techniques require the development of more complex and reliable organ phantoms to assess the performance of the technique before its translation into the clinic. In this work, electrically conductive tissue-mimicking materials (TMMs) based on fat, water and agar/gelatin were produced with tunable optical properties. The composition of the phantoms allowed for the assessment of tumor margins using diffuse reflectance spectroscopy, as the fat/water ratio served as a discriminating factor between the healthy and malignant tissue. Moreover, the possibility of using polyvinyl alcohol (PVA) or transglutaminase in combination with fat, water and gelatin for developing TMMs was studied. The diffuse spectral response of the developed phantom materials had a good match with the spectral response of porcine muscle and adipose tissue, as well as in vitro human breast tissue. Using the developed recipe, anatomically relevant heterogeneous breast phantoms representing the optical properties of different layers of the human breast were fabricated using 3D-printed molds. These TMMs can be used for further development of phantoms applicable for simulating the realistic breast conserving surgery workflow in order to evaluate the intraoperative optical-based tumor margin assessment techniques during electrosurgery.
Collapse
Affiliation(s)
- Sara Azizian Amiri
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology, The Netherlands
| | - Pieter Van Berckel
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology, The Netherlands
| | - Marco Lai
- Philips Research, IGT & US Devices and Systems Department, Eindhoven, The Netherlands
- Eindhoven University of Technology (TU/e), Eindhoven, The Netherlands
| | - Jenny Dankelman
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology, The Netherlands
| | - Benno H. W. Hendriks
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime, and Materials Engineering, Delft University of Technology, The Netherlands
- Philips Research, IGT & US Devices and Systems Department, Eindhoven, The Netherlands
| |
Collapse
|
14
|
Park BJ, Jung YJ, Ro YS, Chang SE, Kim JE. Therapeutic Effects of New Pulsed-Type Microneedling Radiofrequency for Refractory Facial Pigmentary Disorders. Dermatol Surg 2022; 48:327-333. [PMID: 34999602 DOI: 10.1097/dss.0000000000003367] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Numerous treatments for pigmentary disorders have been used with variable outcomes. Recently, a new radiofrequency (RF) device with minimal pulse duration has been introduced. OBJECTIVE The aim of this study was to evaluate the efficacy and safety of a pulsed-type microneedling RF device for treatment of facial pigmentary disorders. METHODS Forty-four patients diagnosed with facial melasma or Riehl melanosis received 5 treatments with RF at 2-week intervals, and evaluation was performed at each visits, including 4 and 8 weeks after the last treatment. Treatment outcomes were evaluated by investigator global assessment, patient global assessment score, and skin biophysical parameters of erythema index, melanin index (MI), and transepidermal water loss. Gene array and immunohistochemical staining including melan-A, Fontana silver, CD44, basic fibroblast growth factor (bFGF), and periodic acid-Schiff were performed. RESULTS Most of the patients showed clinical improvement. Erythema index, MI, and transepidermal water loss decreased after the first treatment. Histopathologic examination showed decrease of melanin pigment, melanophages, and blood vessel proliferation but thickened basement membrane after treatment. Expression of CD44 and b-FGF was decreased after treatment. There were no serious adverse events reported during the study. CONCLUSION Pulsed-type microneedling RF could be a treatment option for facial pigmentary disorders.
Collapse
Affiliation(s)
- Byeong Jin Park
- Department of Dermatology, Hanyang University College of Medicine, Seoul, Korea
| | - You Jin Jung
- Department of Dermatology, Hanyang University College of Medicine, Seoul, Korea
| | - Young Suck Ro
- Department of Dermatology, Hanyang University College of Medicine, Seoul, Korea
| | - Sung Eun Chang
- Department of Dermatology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Korea
| | - Jeong Eun Kim
- Department of Dermatology, Hanyang University College of Medicine, Seoul, Korea
| |
Collapse
|
15
|
Assorted Skin Procedures. Prim Care 2022; 49:47-62. [DOI: 10.1016/j.pop.2021.10.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
16
|
Wasserlauf J, Knight BP. Comparing the safety and effectiveness of dedicated radiofrequency transseptal wires to electrified metal guidewires. J Cardiovasc Electrophysiol 2022; 33:371-379. [PMID: 34978365 PMCID: PMC9303383 DOI: 10.1111/jce.15341] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2021] [Revised: 11/10/2021] [Accepted: 12/06/2021] [Indexed: 12/04/2022]
Abstract
Background Application of electrocautery to a metal guidewire is used by some operators to perform transseptal puncture (TSP). Commercially available dedicated radiofrequency (RF) guidewires may represent a better alternative. This study compares the safety and effectiveness of electrified guidewires to a dedicated RF wire. Methods TSP was performed on freshly excised porcine hearts using an electrified 0.014″ or 0.032″ guidewire under various power settings and was compared to TSP using a dedicated RF wire with 5 W power (0.035″ VersaCross RF System, Baylis Medical). The primary endpoint was the number of attempts required to achieve TSP. Secondary endpoints included the rate of TSP failure, TSP consistency, the effect of the distance between the tip of the guidewire and the tip of the dilator, and effect of RF power output level. Qualitative secondary endpoints included tissue puncture defect appearance, thermal damage to the TSP guidewire or dilator, and tissue temperature using thermal imaging. Results The RF wire required on average 1.10 ± 0.47 attempts to cross the septum. The 0.014″ electrified guidewire required an overall mean of 2.17 ± 2.36 attempts (2.0 times as many as the RF wire; p < .01), and the 0.032″ electrified guidewire required an overall mean of 3.90 ± 2.93 attempts (3.5 times as many as the RF wire; p < .01). Electrified guidewires had a higher rate of TSP failure, and caused larger defects and more tissue charring than the RF wire. Thermal analysis showed higher temperatures and a larger area of tissue heating with electrified guidewires than the RF wire. Conclusion Fewer RF applications were required to achieve TSP using a dedicated RF wire compared to an electrified guidewire. Smaller defects and lower tissue temperatures were also observed using the RF wire. Electrified guidewires required greater energy delivery and were associated with equipment damage and tissue charring, which may present a risk of thrombus, thermal injury, or scarring.
Collapse
Affiliation(s)
- Jeremiah Wasserlauf
- Department of Internal Medicine, Division of Cardiology, Rush University Medical Center, Chicago, Illinois, USA
| | - Bradley P Knight
- Division of Cardiology, Feinberg School of Medicine, Northwestern University, Chicago, Illinois, USA
| |
Collapse
|
17
|
Brinkmann F, Hüttner R, Mehner PJ, Henkel K, Paschew G, Herzog M, Martens N, Richter A, Hinz S, Groß J, Schafmayer C, Hampe J, Hendricks A, Schwandner F. Temperature profile and residual heat of monopolar laparoscopic and endoscopic dissection instruments. Surg Endosc 2022; 36:4507-4517. [PMID: 34708296 PMCID: PMC9085678 DOI: 10.1007/s00464-021-08804-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Accepted: 10/17/2021] [Indexed: 01/29/2023]
Abstract
BACKGROUND Endoscopic and laparoscopic electrosurgical devices (ED) are of great importance in modern medicine but can cause adverse events such as tissue injuries and burns from residual heat. While laparoscopic tools are well investigated, detailed insights about the temperature profile of endoscopic knives are lacking. Our aim is to investigate the temperature and the residual heat of laparoscopic and endoscopic monopolar instruments to increase the safety in handling ED. METHODS An infrared camera was used to measure the temperature of laparoscopic and endoscopic instruments during energy application and to determine the cooling time to below 50 °C at a porcine stomach. Different power levels and cutting intervals were studied to investigate their impact on the temperature profile. RESULTS During activation, the laparoscopic hook exceeded 120 °C regularly for an up to 10 mm shaft length. With regards to endoknives, only the Dual Tip Knife showed a shaft temperature of above 50 °C. The residual heat of the laparoscopic hook remained above 50 °C for at least 15 s after activation. Endoknives cooled to below 50 °C in 4 s. A higher power level and longer cutting duration significantly increased the shaft temperature and prolonged the cooling time (p < 0.001). CONCLUSION Residual heat and maximum temperature during energy application depend strongly on the chosen effect and cutting duration. To avoid potential injuries, the user should not touch any tissue with the laparoscopic hook for at least 15 s and with the endoknives for at least 4 s after energy application. As the shaft also heats up to over 120 °C, the user should be careful to avoid tissue contact during activation with the shaft. These results should be strongly considered for safety reasons when handling monopolar ED.
Collapse
Affiliation(s)
- Franz Brinkmann
- Department of Medicine I, University Hospital Dresden, Technische Universität Dresden (TU Dresden), Dresden, Germany ,Chair of Microsystems, Faculty of Electrical and Computer Engineering, Technische Universität Dresden (TU Dresden), Dresden, Germany ,Else Kröner Fresenius Center for Digital Health, Technische Universität Dresden (TU Dresden), Dresden, Germany ,Department of Medicine I, University Hospital Carl Gustav Carus, Technische Universität Dresden (TU Dresden), Fetscherstr. 74, 01307 Dresden, Germany
| | - Ronny Hüttner
- Chair of Microsystems, Faculty of Electrical and Computer Engineering, Technische Universität Dresden (TU Dresden), Dresden, Germany
| | - Philipp J. Mehner
- Chair of Microsystems, Faculty of Electrical and Computer Engineering, Technische Universität Dresden (TU Dresden), Dresden, Germany
| | - Konrad Henkel
- Chair of Microsystems, Faculty of Electrical and Computer Engineering, Technische Universität Dresden (TU Dresden), Dresden, Germany
| | - Georgi Paschew
- Chair of Microsystems, Faculty of Electrical and Computer Engineering, Technische Universität Dresden (TU Dresden), Dresden, Germany
| | - Moritz Herzog
- Department of Medicine I, University Hospital Dresden, Technische Universität Dresden (TU Dresden), Dresden, Germany ,Else Kröner Fresenius Center for Digital Health, Technische Universität Dresden (TU Dresden), Dresden, Germany
| | - Nora Martens
- Department of Medicine I, University Hospital Dresden, Technische Universität Dresden (TU Dresden), Dresden, Germany ,Else Kröner Fresenius Center for Digital Health, Technische Universität Dresden (TU Dresden), Dresden, Germany
| | - Andreas Richter
- Chair of Microsystems, Faculty of Electrical and Computer Engineering, Technische Universität Dresden (TU Dresden), Dresden, Germany ,Else Kröner Fresenius Center for Digital Health, Technische Universität Dresden (TU Dresden), Dresden, Germany
| | - Sebastian Hinz
- Department of General, Visceral, Vascular and Transplantation Surgery, University Medical Center Rostock, Rostock, Germany
| | - Justus Groß
- Department of General, Visceral, Vascular and Transplantation Surgery, University Medical Center Rostock, Rostock, Germany
| | - Clemens Schafmayer
- Department of General, Visceral, Vascular and Transplantation Surgery, University Medical Center Rostock, Rostock, Germany
| | - Jochen Hampe
- Department of Medicine I, University Hospital Dresden, Technische Universität Dresden (TU Dresden), Dresden, Germany ,Else Kröner Fresenius Center for Digital Health, Technische Universität Dresden (TU Dresden), Dresden, Germany
| | - Alexander Hendricks
- Department of General, Visceral, Vascular and Transplantation Surgery, University Medical Center Rostock, Rostock, Germany
| | - Frank Schwandner
- Department of General, Visceral, Vascular and Transplantation Surgery, University Medical Center Rostock, Rostock, Germany
| |
Collapse
|
18
|
Abstract
Electrosurgery applies high frequency alternating electrical currents to generate heat, thereby creating tissue damage required for cutting, hemostasis, or destruction. Electrosurgery can be delivered in a variety of different ways and can be tailored to achieve the desired clinical effect. Having a command of the underlying principles of electrosurgery will help dermatologic surgeons use the appropriate form of electrosurgery to safely achieve the desired results. We reviewed basic principles of electrosurgery, described the various techniques and devices, and delineated associated risks of electrosurgery for specific patient populations and providers. All modalities of electrosurgery present a risk of electromagnetic interference, which can negatively affect patients with implanted devices, such as pacemakers, defibrillators, cochlear implants, and deep brain stimulators. In particular, electrosurgery may create a smoke plume containing a number of volatile organic compounds potentially noxious; however, the risk of such exposure remains unknown.
Collapse
Affiliation(s)
- Ariana Eginli
- Center for Dermatology Research, Department of Dermatology, Wake Forest School of Medicine, Winston-Salem, North Carolina, USA.
| | - Wasim Haidari
- Center for Dermatology Research, Department of Dermatology, Wake Forest School of Medicine, Winston-Salem, North Carolina, USA
| | - Michael Farhangian
- Center for Dermatology Research, Department of Dermatology, Wake Forest School of Medicine, Winston-Salem, North Carolina, USA
| | - Phillip M Williford
- Center for Dermatology Research, Department of Dermatology, Wake Forest School of Medicine, Winston-Salem, North Carolina, USA
| |
Collapse
|
19
|
Zhong Y, Wei Y, Min N, Guan Q, Zhao J, Zhu J, Hu H, Geng R, Hong C, Ji Y, Li J, Zheng Y, Zhang Y, Li X. Comparative healing of swine skin following incisions with different surgical devices. ANNALS OF TRANSLATIONAL MEDICINE 2021; 9:1514. [PMID: 34790720 PMCID: PMC8576679 DOI: 10.21037/atm-21-3090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/15/2021] [Accepted: 08/05/2021] [Indexed: 11/06/2022]
Abstract
Background Electrosurgical technology is widely used in surgical dissection and hemostasis, but the generated heat creates thermal injury to adjacent tissues and delays wound healing. The plasma blade (PB) applies pulsed radiofrequency (RF) to generate electrical plasma along the edge of a thin, flat, insulated electrode, minimizing collateral tissue damage. This study aimed to evaluate wound healing in swine skin following incision with a new surgical system that applies low-temperature plasma (NTS-100), a foreign PB, conventional electrosurgery (ES), and a scalpel blade. Methods In vitro porcine skin and an in vivo porcine skin model were used in this study. Full-thickness skin incisions 3 cm in length were made on the dorsum of each animal for each of the 5 surgical procedures at 0, 21, 28, 35, and 42 days. The timing of the surgical procedures allowed for wound-healing data points at 1, 2, 3, and 6 weeks accordingly. Local operating temperature and blood loss were quantified. Wounds were harvested at designated time points, tested for wound tensile strength, and examined histologically for scar formation and tissue damage. Results Local operating temperature was reduced significantly with NTS-100 (cut mode 83.12±23.55 °C; coagulation mode 90.07±10.6 °C) compared with PB (cut mode 94.46±11.48 °C; coagulation mode 100.23±6.58 °C, P<0.05) and ES (cut mode 208.99±34.33 °C, P<0.01; coagulation mode 233.37±28.69 °C, P<0.01) in vitro. Acute thermal damage from NTS-100 was significantly less than ES incisions (cut mode: 247.345±42.274 versus 495.295±103.525 µm, P<0.01; coagulation mode: 351.419±127.948 versus 584.516±31.708 µm, P<0.05). Bleeding, histological scoring of injury, and wound strength were equivalent for the NTS-100 and PB incisions. Conclusions The local operating temperature of NTS-100 was lower than PB, and NTS-100 had similarly reliable safety and efficacy.
Collapse
Affiliation(s)
- Yuting Zhong
- Medical School of Chinese PLA, Beijing, China.,Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China
| | - Yufan Wei
- Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China.,School of Medicine, Nankai University, Tianjin, China
| | - Ningning Min
- Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China.,School of Medicine, Nankai University, Tianjin, China
| | - Qingyu Guan
- Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China.,School of Medicine, Nankai University, Tianjin, China
| | - Jin Zhao
- Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China
| | - Junyong Zhu
- Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China
| | - Huayu Hu
- Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China.,School of Medicine, Nankai University, Tianjin, China
| | - Rui Geng
- Medical School of Chinese PLA, Beijing, China.,Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China
| | - Chenyan Hong
- Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China.,School of Medicine, Nankai University, Tianjin, China
| | - Yashuang Ji
- Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China.,School of Medicine, Nankai University, Tianjin, China
| | - Jie Li
- Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China
| | - Yiqiong Zheng
- Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China
| | - Yanjun Zhang
- Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China
| | - Xiru Li
- Department of General Surgery, Chinese People's Liberation Army General Hospital, Beijing, China
| |
Collapse
|
20
|
Static Crow's Feet Treated with Voltaic Arc Dermabrasion (Atmospheric Plasma): Post-Operative Pain Assessment by Thermal Infrared Imaging. J Clin Med 2021; 10:jcm10143074. [PMID: 34300242 PMCID: PMC8305919 DOI: 10.3390/jcm10143074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Revised: 06/30/2021] [Accepted: 07/07/2021] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND In the literature, several strategies have been described for the treatment of unaesthetic marks on the face resulting from the aging processes. The atmospheric plasma procedure is a non-invasive, inexpensive technique proposed for the rejuvenation of facial tissues. The aim of this study was to evaluate the performance of voltaic arc dermabrasion (VAD) for the treatment of static crow's feet of the periorbital area. METHODS The crow's feet of 135 patients (127 female and 8 male) were treated using the VAD technique. The perioperative skin temperature measurement was assessed using an Infrared Temperature sensor. The pain was measured using the Visual Analogic Score (VAS) at 1 week, 1 month and 1 year. The patient's and surgeon's satisfaction were assessed using the Global Aesthetic Improvement Scale (GAIS) at 1 month and 1 year from the procedure. The severity of the crow's feet was rated using the Crow's Feet Grading Scale (CFGS). RESULTS A complete epidermal healing of all the subjects treated was evident at 7 days. The atmospheric plasma technique showed an efficient treatment for the removal of the crow's feet, with a good aesthetic outcome, high surgeon and patient satisfaction, without clinical complications. CONCLUSIONS The atmospheric plasma technique can be a useful modality in the cosmetic as well as therapeutic treatment of crow's feet.
Collapse
|
21
|
Kawamura A, Akiba Y, Nagasawa M, Takashima M, Arai Y, Uoshima K. Bone heating and implant removal using a high-frequency electrosurgical device: An in vivo experimental study. Clin Oral Implants Res 2021; 32:989-997. [PMID: 34107095 DOI: 10.1111/clr.13793] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 01/27/2021] [Accepted: 03/16/2021] [Indexed: 11/29/2022]
Abstract
OBJECTIVES Failed implant removal using a high-frequency electrosurgical device (HFED) has been reported to be less invasive than other surgical techniques. We sought to clarify the mechanism of removal torque reduction in an implant by heating with HFED. MATERIALS AND METHODS Sixty-eight Wistar rats received titanium implants on the maxillary bone 4 weeks after extraction of the first and second molars. The control group was sacrificed 6 weeks after implant installation. In the experimental group, the implant was heated by HFED for 10 s using three different power outputs, and samples were collected at 3, 7, and 14 days after heating. Removal torque measurement and histological analysis were performed in the control and experimental groups. Implant surfaces were observed using an electron-probe microanalyzer (EPMA). Data were analyzed using Mann-Whitney U test at a significance level of 5%. RESULTS The removal torque could not be measured in the control group due to fracture of the implant. After heating, the removal torque was measurable without fracture and decreased significantly at 14 days as compared with that at 3 days (p < .05). Heating with "min" power output resulted in a significantly smaller blank lacunae area and fewer osteoclasts at 14 days after heating (p < .05). EPMA revealed bone matrix adherence to outer surface of heated implant. CONCLUSIONS After heating, an enlarged area of blank lacunae around the implant and an increased number of osteoclasts into the bone marrow cavity were observed, which may have contributed to the reduction in removal torque.
Collapse
Affiliation(s)
- Atsushi Kawamura
- Oral Implant and Temporomandibular Joint Clinic, Medical and Dental Hospital, Niigata University, Niigata, Japan
| | - Yosuke Akiba
- Divisions of Bio-prosthodontics, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| | - Masako Nagasawa
- Divisions of Bio-prosthodontics, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| | - Makiko Takashima
- Oral Implant and Temporomandibular Joint Clinic, Medical and Dental Hospital, Niigata University, Niigata, Japan
| | - Yoshiaki Arai
- Oral Implant and Temporomandibular Joint Clinic, Medical and Dental Hospital, Niigata University, Niigata, Japan
| | - Katsumi Uoshima
- Divisions of Bio-prosthodontics, Niigata University Graduate School of Medical and Dental Sciences, Niigata, Japan
| |
Collapse
|
22
|
Boergens KM, Tadić A, Hopper MS, McNamara I, Fell D, Sahasrabuddhe K, Kong Y, Straka M, Sohal HS, Angle MR. Laser ablation of the pia mater for insertion of high-density microelectrode arrays in a translational sheep model. J Neural Eng 2021; 18. [PMID: 34038875 DOI: 10.1088/1741-2552/ac0585] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/20/2020] [Accepted: 05/26/2021] [Indexed: 01/03/2023]
Abstract
Objective. The safe insertion of high density intracortical electrode arrays has been a long-standing practical challenge for neural interface engineering and applications such as brain-computer interfaces (BCIs). However, the pia mater can be difficult to penetrate and causes deformation of underlying cortical tissue during insertion of high-density intracortical arrays. This can lead to neuron damage or failed insertions. The development of a method to ease insertion through the pia mater would represent a significant step toward inserting high density intracortical arrays.Approach. Here we describe a surgical procedure, inspired by laser corneal ablation, that can be used in translational models to thin the pia mater.Main results. We demonstrate that controlled pia removal with laser ablation over a small area of cortex allows for microelectrode arrays to be inserted into the cortex with less force, thus reducing deformation of underlying tissue during placement of the microelectrodes. This procedure allows for insertion of high-density electrode arrays and subsequent acute recordings of spiking neuron activity in sheep cortex. We also show histological and electrophysiological evidence that laser removal of the pia does not acutely affect neuronal viability in the region.Significance. Laser ablation of the pia reduces insertion forces of high-density arrays with minimal to no acute damage to cortical neurons. This approach suggests a promising new path for clinical BCI with high-density microelectrode arrays.
Collapse
Affiliation(s)
| | | | | | | | - Devin Fell
- Paradromics, Inc., Austin, TX, United States of America
| | | | - Yifan Kong
- Paradromics, Inc., Austin, TX, United States of America
| | | | | | | |
Collapse
|
23
|
Fuertes I, Cranston R, de Lazzari E, Rodriguez-Carunchio L, Blanco JL. Response factors associated with electrocautery treatment of intra-anal high-grade squamous intraepithelial lesions in a population of HIV-positive men who have sex with men. Int J STD AIDS 2021; 32:1052-1059. [PMID: 33978536 DOI: 10.1177/09564624211017005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
BACKGROUND Ablative treatment of anal high-grade squamous intraepithelial lesions (HSIL) reduces the risk of progression to anal squamous cell carcinoma. OBJECTIVES To identify factors that influence the response to treatment of anal HSIL by electrocautery ablation (ECA) in a population of HIV-positive men who have sex with men (MSM). DESIGN Retrospective study of ECA treatment response in a prospectively followed anal dysplasia cohort. HIV-positive MSM diagnosed with anal HSIL were included. Demographic and HIV data were recorded. Response to treatment was assessed by biopsy after at least 18 months of follow-up. RESULTS One hundred and twenty-eight HSILs in 91 men were included in this study. The overall response rate at 18 months was 70.3%. The number of electrocautery sessions required (2 ECA sessions vs 1: adjusted odds ratio [aOR] = 0.36 (95%CI 0.13-1.01); >=3 sessions vs 1: aOR = 0.10 (95%CI 0.04-0.29); p < 0.001]) and the history of previous HPV-related anal pathology (previous anal lesions vs no previous lesions AOR = 2.83 (95%CI 1.14-7.02), p = 0.024) were independently associated with response at 18 months. No serious adverse events were reported. CONCLUSIONS Consideration should be given to alternative therapies in patients with unresolved HSIL after 1 ECA treatment.
Collapse
Affiliation(s)
- Irene Fuertes
- Department of Dermatology, 16493Hospital Clinic of Barcelona, University of Barcelona, Barcelona, Spain
| | - Ross Cranston
- Department of Infectious Diseases, 16493Hospital Clinic of Barcelona, University of Barcelona, Barcelona, Spain
| | - Elisa de Lazzari
- Department of Infectious Diseases, 16493Hospital Clinic of Barcelona, University of Barcelona, Barcelona, Spain
| | | | - José L Blanco
- Department of Infectious Diseases, 16493Hospital Clinic of Barcelona, University of Barcelona, Barcelona, Spain
| |
Collapse
|
24
|
Cattoni M, Rotolo N, Nardecchia E, De Maio S, Dominioni L, Imperatori A. Energy devices safety and impact on video-assisted thoracoscopic lung lobectomy postoperative course: monopolar electrocautery versus ultrasonic dissector. J Cardiothorac Surg 2021; 16:40. [PMID: 33743749 PMCID: PMC7981968 DOI: 10.1186/s13019-021-01421-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Accepted: 03/11/2021] [Indexed: 11/25/2022] Open
Abstract
Background This study aims to compare safety and impact of monopolar electrocautery and ultrasonic dissector (Harmonic ACE Plus®) on postoperative short-term outcomes after video-assisted thoracoscopic (VATS) lobectomy and lymphadenectomy for lung cancer. Methods We analyzed the prospectively collected data of 140 consecutive patients [59% male; median age: 71(IQR:62–76) years] undergoing VATS lobectomy and lymphadenectomy in our institution between October 2016 and November 2019. Patients were divided in two groups based on device used: monopolar electric hook in 79 cases (Group A); ultrasonic dissector in 61(Group B). Energy instrument-related intraoperative accidents, hemothorax/chylothorax incidence, total pleural effusion volume at 48 postoperative hours and chest tube duration were compared between groups. Multivariable analysis was performed to test energy device as possible independent risk factor either for increased pleural effusion volume or for prolonged chest tube duration. Results No intraoperative accidents due to energy device occurred. No hemothorax was recorded. Postoperative chylothorax incidence was slightly higher in Group A (2.5% vs 0%; p-value = 0.21). Total pleural effusion volume at 48 h was significantly higher in Group B: 400 (285–500) vs 255 (150–459) ml (p-value = 0.005). Chest tube duration was similar in the two groups: 5 (3–9) vs 5 (3–8) days (p-value = 0.77). At multivariable analysis the energy device used was not associated with increased pleural effusion volume (p-value = 0.43) nor with prolonged chest tube duration (p-value = 0.28). Conclusions Monopolar electrocautery and Harmonic ACE Plus® were safe and had a similar impact on short-term outcomes after VATS lobectomy and lymphadenectomy, suggesting that energy devices choice could be left to surgeon’s preference.
Collapse
Affiliation(s)
- Maria Cattoni
- Center for Thoracic Surgery and Center for Minimally Invasive Surgery, Department of Medicine and Surgery, University of Insubria, Via Guicciardini 9, 21100, Varese, Italy
| | - Nicola Rotolo
- Center for Thoracic Surgery and Center for Minimally Invasive Surgery, Department of Medicine and Surgery, University of Insubria, Via Guicciardini 9, 21100, Varese, Italy
| | - Elisa Nardecchia
- Center for Thoracic Surgery and Center for Minimally Invasive Surgery, Department of Medicine and Surgery, University of Insubria, Via Guicciardini 9, 21100, Varese, Italy
| | - Silvia De Maio
- Center for Thoracic Surgery and Center for Minimally Invasive Surgery, Department of Medicine and Surgery, University of Insubria, Via Guicciardini 9, 21100, Varese, Italy
| | - Lorenzo Dominioni
- Center for Thoracic Surgery and Center for Minimally Invasive Surgery, Department of Medicine and Surgery, University of Insubria, Via Guicciardini 9, 21100, Varese, Italy
| | - Andrea Imperatori
- Center for Thoracic Surgery and Center for Minimally Invasive Surgery, Department of Medicine and Surgery, University of Insubria, Via Guicciardini 9, 21100, Varese, Italy.
| |
Collapse
|
25
|
Radmilović-Radjenović M, Sabo M, Radjenović B. Application of multi-component fluid model in studies of the origin of skin burns during electrosurgical procedures. Comput Methods Biomech Biomed Engin 2021; 24:1409-1418. [PMID: 33667151 DOI: 10.1080/10255842.2021.1890721] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/22/2022]
Abstract
This paper reports on safety challenges regarding spark created when the applied electric field exceeds the dielectric breakdown strength as a source of complication during electrosurgery. Despite the unquestionable benefits of electrosurgery, such as minimal chances of infection and fast recovery time, the interaction of the electrosurgical tool with the tissue may result in tissue damage and force feedback to the tool. Some risks of complications often depend on a surgeon's knowledge of instruments and safety aspects of technical equipment that can be eliminated by clarifying the causation and conditions of their development. Current trends in electrosurgery include computational algorithms and methods to control the effect of delivered energy to the patient. For this study, calculations were performed by using the COMSOL simulation package based on a multi-component plasma fluid model. The emphasis is put on conditions that lead to the breakdown of the dielectric medium. It was found that breakdown occurs most easily when both electrodes are cylindrical. For configurations with one or two spherical electrodes, breakdown voltages are higher up to 25% and 48%, respectively. With decreasing the cathode radius, the breakdown voltage may decrease even to 41%. On the other hand, the temperature increase lowers the breakdown voltage. Also, electrical asymmetries appear to be a response to the non-symmetry of the electric field between the electrodes causing differences in the breakdown voltage between 36% and 70%. The results presented here could be very useful for the design of surgical devices to prevent potential complications of electrosurgical procedures.
Collapse
Affiliation(s)
| | - Martin Sabo
- Faculty of Informatics and Information Technologies, Slovak University of Technology in Bratislava, Bratislava, Republic of Slovakia
| | - Branislav Radjenović
- Institute of Physics Belgrade, University of Belgrade, Pregrevica, Belgrade, Serbia
| |
Collapse
|
26
|
Strickler AG, Shah P, Bajaj S, Mizuguchi R, Nijhawan RI, Odueyungbo M, Rossi A, Ratner D. Preventing and managing complications in dermatologic surgery: Procedural and postsurgical concerns. J Am Acad Dermatol 2021; 84:895-903. [PMID: 33493570 DOI: 10.1016/j.jaad.2021.01.037] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Revised: 01/14/2021] [Accepted: 01/14/2021] [Indexed: 12/17/2022]
Abstract
The second article in this continuing medical education series reviews the evidence regarding the intraoperative and postoperative risks for patients and health care workers. We share the most up-to-date recommendations for risk management and postoperative complication management to ensure optimal surgical efficacy and patient safety.
Collapse
Affiliation(s)
- Allen G Strickler
- Department of Dermatology, Geisinger Medical Center of Geisinger Commonwealth School of Medicine, Danville, Pennsylvania; Department of Laboratory Medicine, Geisinger Medical Center of Geisinger Commonwealth School of Medicine, Danville, Pennsylvania.
| | - Payal Shah
- School of Medicine, New York University Langone Health, New York, New York
| | - Shirin Bajaj
- Department of Dermatology, New York University Langone Health, New York, New York
| | - Richard Mizuguchi
- Department of Dermatology, Mount Sinai Medical School, New York, New York
| | - Rajiv I Nijhawan
- Department of Dermatology, University of Texas Southwestern Medical Center, Dallas, Texas
| | | | - Anthony Rossi
- Weill Cornell Medical College, Memorial Sloan Kettering Cancer Center, New York, New York
| | - Désirée Ratner
- Department of Dermatology, New York University Langone Health, New York, New York
| |
Collapse
|
27
|
Scarano A, Carinci F, Candotto V, Lorusso F. Eradication of Benign Skin Lesions of the Face by Voltaic Arc Dermabrasion (Atmospheric Plasma): Postoperative Pain Assessment by Thermal Infrared Imaging. Aesthetic Plast Surg 2020; 44:2277-2285. [PMID: 32767038 PMCID: PMC7683462 DOI: 10.1007/s00266-020-01891-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2020] [Accepted: 07/19/2020] [Indexed: 11/04/2022]
Abstract
Objectives The face aging processes are associated with physiologic and biochemical alteration that produces wrinkles, skin pigmentation and benign growths. The aim of this study was to evaluate the clinical efficacy of voltaic arc dermabrasion with plasma to remove benign facial skin lesions. Study Design Voltaic arc dermabrasion plasma technique was used to remove the facial benign skin lesions. The study involved 45 patients (26 females;19 males) treated for benign facial skin lesions with voltaic arc dermabrasion also called plasma exeresis technique. The subjects age ranged between 43 and 65 years. The clinical observations and comparison of pretreatment and post-treatment photographs of the treated regions were performed by a joint examiner at each follow-up visit. Results During plasma irradiation, the average temperature of the skin was 290.3 ± 21.7 °C, while immediately after it was 90.6 ± 21.8 °C. Overall clinical improvement was 100% in six lesions with complete resolution of all lesions. Three patients observed a transient post-inflammatory pigmentation with a peak at 1 month after VAD treatment, gradually fading spontaneously over 2 to 3 months. Conclusions The voltaic arc dermabrasion technique (atmospheric plasma) should be considered for lesions, especially relatively superficial ones, and small lesions that are located on the face. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266.
Collapse
|
28
|
Lutfallah C, Looi T, Drake J. A Novel Bipolar Cautery Tool for Minimally-Invasive Neuroendoscopic Procedures. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2020:6062-6065. [PMID: 33019353 DOI: 10.1109/embc44109.2020.9176415] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Electrosurgery is used in the operating room on a daily basis as a means to cut tissue and maintain hemostasis. The principle of this technology lies in the transfer of electricity from an electrosurgical unit to the operating site on a patient's body and modifying the waveform of that electricity to achieve the desired surgical effect. Bipolar cautery uses two electrodes, an active and a return, both at the surgical site to perform electrosurgery. Bipolar cautery can be very useful in helping surgeons to operate; however, current designs are not well suited to a 2.1 mm working channel in endoscopic procedures due to their rigid structure, limited range of motion, and bulky design. This paper describes a novel approach to designing a minimally- invasive bipolar cautery tool suitable for flexible neuroendoscopy. The system features 1.9 mm diameter bipolar tips which resemble grasping forceps, making it easier for surgeons to hold tissue while performing electrosurgery. The electrode wires also function as the actuating cables used to open and close the tips, which require 2.10 mm to open the tips to 30.9 °. The results show that the tool can safely cauterize a porcine brain specimen at various settings on the electrosurgical unit, and increasing the setting increases the area of tissue affected by the electricity. Repeatability was demonstrated and exhaustion was reached after the tool was opened and closed 73 times. Future work will involve improving the current design to increase the number of cycles the tool can survive before losing function.
Collapse
|
29
|
Wootten S, Zawacki ZE, Rheins L, Meschter C, Draelos ZD. An evaluation of electrocoagulation and thermal diffusion following radiofrequency microneedling using an in vivo porcine skin model. J Cosmet Dermatol 2020; 20:1133-1139. [PMID: 32846042 PMCID: PMC8048620 DOI: 10.1111/jocd.13690] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Revised: 07/13/2020] [Accepted: 08/04/2020] [Indexed: 12/14/2022]
Abstract
BACKGROUND Few studies exist that examined the role of radiofrequency microneedling (RFMN) in skin electrocoagulation. This research utilized a porcine model to understand bipolar dermal delivery from an RFMN device. AIMS The objective of this study was to elucidate and compare the dermal thermal effects of a RFMN device producing 1 and 2 MHz signal amplitudes, with respective voltage and current gradients, utilizing noninsulated and insulated needles by examining the histologic effects on porcine skin. METHODS Two separate animal studies were conducted to evaluate the electrocoagulation and thermal diffusion effects using the RFMN device. The electrocoagulation effects were assessed histologically using hematoxylin and eosin (H&E) staining, and heating effects were assessed through thermal imaging. RESULTS Histology results of the thermal injury induced by insulated needles demonstrated that 2 MHz resulted in a narrow and concentrated coagulation zone as compared to 1 MHz. Further, the 1 MHz insulated needle resulted in ovular shaped tissue coagulation as compared to 2 MHz tissue coagulation that was columnar. Finally, full thermal diffusion occurs seconds after the set RF conduction time. CONCLUSION The findings showed that 1 MHz insulated needle produces larger coagulations with an increase in power level, the 1 MHz noninsulated array was comparable to the 2 MHz insulated array with similar histologic features, and heat dissipates seconds after the set conduction time.
Collapse
Affiliation(s)
- Shaun Wootten
- Department of Research and Development, Aesthetics Biomedical Inc., Phoenix, AZ, USA
| | - Zosia E Zawacki
- Department of Research Services, Comparative Biosciences Inc., Sunnyvale, CA, USA
| | - Lawrence Rheins
- Department of Research and Development, Aesthetics Biomedical Inc., Phoenix, AZ, USA
| | - Carol Meschter
- Department of Research Services, Comparative Biosciences Inc., Sunnyvale, CA, USA
| | | |
Collapse
|
30
|
Wernick BD, Furlough CL, Patel U, Samant S, Hoel AW, Rodriguez HE, Tomita TT, Eskandari MK. Contemporary management of carotid body tumors in a Midwestern academic center. Surgery 2020; 169:700-704. [PMID: 32868107 DOI: 10.1016/j.surg.2020.07.030] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 07/25/2020] [Accepted: 07/25/2020] [Indexed: 10/23/2022]
Abstract
BACKGROUND Carotid body tumors are rare, neurogenic tumors arising from the periadventitial chemoreceptive tissue of the carotid body. The purpose of this study is to ascertain the presentation and preoperative risk factors associated with surgical resection. METHODS A single-center retrospective review of 25 carotid body tumor resections from 2002 to 2019. Demographics, periprocedural details, and postoperative outcomes were analyzed using Stata (Stata Corporation, College Station, TX). RESULTS Among 25 patients, 64% were women, 84% were asymptomatic, and the mean age was 49 years (range 21-79). Forty-four percent of tumors were Shamblin III. Nine patients underwent preoperative embolization but did not correlate with decreased blood loss (299 cm3 vs 205 cm3, P = .35). The 30-day death, stroke, and cranial nerve injury rates were 0%, 8%, and 32%, respectively. Cranial nerve injuries included 20% vagus, 4% hypoglossal, 4% facial, and 4% glossopharyngeal, with permanent deficits in 4% (n = 1). Mean length of stay was 3.0 days (range 1-9 days). At a mean follow-up of 12 months (range 1-63 months), there has been no recurrence. CONCLUSION Although carotid body tumors are uncommon in the Midwest, complete surgical resection is curative of these typically hormonally inactive tumors. Preoperative embolization did not affect blood loss, and the incidence of death, stroke, and permanent cranial nerve injury rates remained very low.
Collapse
Affiliation(s)
- Brian Daniel Wernick
- Division of Vascular Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL
| | - Courtney L Furlough
- Division of Vascular Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL
| | - Urjeet Patel
- Department of Otolaryngology, Northwestern University Feinberg School of Medicine, Chicago, IL
| | - Sandeep Samant
- Department of Otolaryngology, Northwestern University Feinberg School of Medicine, Chicago, IL
| | - Andrew W Hoel
- Division of Vascular Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL
| | - Heron E Rodriguez
- Division of Vascular Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL
| | - Tadaki T Tomita
- Division of Vascular Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL
| | - Mark K Eskandari
- Division of Vascular Surgery, Northwestern University Feinberg School of Medicine, Chicago, IL.
| |
Collapse
|
31
|
Kim J, Kwon Y, Jun DK, Lee M, Shin D, Kim S, Jo D, Kim C, Kim H, Choi H. Bipolar or monopolar electrosurgery in blepharoplasty: A comparison of surgical outcomes and patient satisfaction. J Cosmet Dermatol 2020; 19:3331-3337. [PMID: 32692892 DOI: 10.1111/jocd.13478] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 04/27/2020] [Accepted: 05/04/2020] [Indexed: 11/28/2022]
Abstract
BACKGROUND An electrosurgery unit (ESU) is the mainstay of bleeding control in blepharoplasty. There are two different types of ESUs: monopolar (m-ESU) and bipolar (b-ESU). AIMS We used m- and b-ESUs in upper, lower, and combined blepharoplasty and compared their outcomes. PATIENTS/METHODS In this retrospective file review of 292 blepharoplasty patients, we excluded 14 who were lost to follow-up or had missing data; among the 278 enrolled patients, we recorded operative time, a surgeon panel's score for edema and ecchymosis on the third postoperative day, patients' scores of their satisfaction and inconvenience, and postoperative complications. RESULTS One hundred thirty-nine patients were included in the m-ESU and b-ESU group. Overall, 105 patients underwent upper blepharoplasty, 77 underwent lower blepharoplasty, and 96 underwent combined blepharoplasty. The total mean operative time in the m-ESU and b-ESU was 67.94 and 62.82 minutes, respectively. This difference was not significant (P > .05). The panel's edema and patient satisfaction and inconvenience scores were significantly better in the b-ESU group (P < .05). There were no significant differences in the panel's ecchymosis score and frequency as well as nature of complications between the m-ESU and b-ESU group (P > .05). CONCLUSIONS In this cohort of blepharoplasty patients, minimally invasive b-ESUs were efficient in obtaining reliable surgical results with higher satisfaction and lower inconvenience rates of patients than m-ESUs. We would like to recommend the use of b-ESUs in blepharoplasty, especially for plastic surgeons inexperienced in periorbital esthetic surgery.
Collapse
Affiliation(s)
- Jeenam Kim
- Department of Plastic and Reconstructive Surgery, Konkuk University School of Medicine, Seoul, Korea
| | - Yongseok Kwon
- Department of Plastic and Reconstructive Surgery, Konkuk University School of Medicine, Seoul, Korea
| | - Dong-Keun Jun
- Department of Plastic and Reconstructive Surgery, Konkuk University School of Medicine, Seoul, Korea
| | - Myungchul Lee
- Department of Plastic and Reconstructive Surgery, Konkuk University School of Medicine, Seoul, Korea
| | - Donghyeok Shin
- Department of Plastic and Reconstructive Surgery, Konkuk University School of Medicine, Seoul, Korea
| | - Soonheum Kim
- Department of Plastic and Reconstructive Surgery, Konkuk University School of Medicine, Seoul, Korea
| | - Dongin Jo
- Department of Plastic and Reconstructive Surgery, Konkuk University School of Medicine, Seoul, Korea
| | - Cheolkeun Kim
- Department of Plastic and Reconstructive Surgery, Konkuk University School of Medicine, Seoul, Korea
| | | | - Hyungon Choi
- Department of Plastic and Reconstructive Surgery, Konkuk University School of Medicine, Seoul, Korea
| |
Collapse
|
32
|
Kshirsagar RS, Hong EM, Pham TT, Wong BJF. Electrosurgery Turbinate Reduction Revisited: Can Comparable Volumetric Heating be Achieved Without Feedback Control? Lasers Surg Med 2020; 53:370-376. [PMID: 32644221 DOI: 10.1002/lsm.23293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2020] [Revised: 05/07/2020] [Accepted: 06/17/2020] [Indexed: 11/10/2022]
Abstract
BACKGROUND AND OBJECTIVES Temperature-controlled radiofrequency inferior turbinate ablation (TCRFA) uses a feedback system to control thermal injury and achieve precise volumetric heating to induce specific scar formation. However, it requires costly single-use proprietary consumables. Comparable volumetric tissue heating may be achieved for a fraction of the cost by adjusting the power settings on traditional monopolar electrosurgery devices that use low-cost needle tips. This pre-clinical study aims to determine the optimized power parameters to achieve electrosurgical coagulum volume similar to that of TCRFA. STUDY DESIGN/MATERIALS AND METHODS An electrosurgery submucosal diathermy (SMD) system (cut mode, 4-32 W, 5-120 seconds) and a temperature-controlled radiofrequency ablation system (standard clinical parameters for treating inferior turbinate hypertrophy) were used to coagulate egg white and chicken breast. Coagulum major and minor axis were measured, and lesion volume was approximated as prolate spheroid. RESULTS No significant difference in volume was found between the temperature-controlled system and the electrosurgery system at 8 W for 30 seconds, 8 W for 60 seconds, 16 W for 30 seconds, 32 W for 5 seconds, and 32 W for 15 seconds. The time to achieve equivalent lesion size was significantly less in the SMD system when compared to the temperature-controlled system (P < 0.05). CONCLUSION Electrosurgery handpieces may achieve similar lesion volume effects as the temperature feedback-controlled, single-use handpieces when set to the optimized parameters. SMD handpieces are significantly more cost and time effective than proprietary devices, and they are easily used in the office. SMD devices may be a more affordable alternative to temperature-controlled systems with comparable lesion volume effect and may be valuable for office-based therapy. Lasers Surg. Med. © 2020 Wiley Periodicals LLC.
Collapse
Affiliation(s)
- Rijul S Kshirsagar
- Department of Head and Neck Surgery, Kaiser Permanente Oakland Medical Center, 3600 Broadway, Oakland, California, 94611, USA
| | - Ellen M Hong
- Beckman Laser Institute, University of California, 1002 Health Sciences Rd, Irvine, California, 92612, USA
| | - Tiffany T Pham
- Beckman Laser Institute, University of California, 1002 Health Sciences Rd, Irvine, California, 92612, USA
| | - Brian J F Wong
- Beckman Laser Institute, University of California, 1002 Health Sciences Rd, Irvine, California, 92612, USA.,Department of Otolaryngology - Head and Neck Surgery, School of Medicine, University of California - Irvine, 101 The City Dr S, Orange, California, 92868, USA.,Department of Biomedical Engineering, University of California - Irvine, 402 E Peltason Dr, California, 92612, USA
| |
Collapse
|
33
|
Lin W, Dai Y, Niu J, Yang G, Li M, Wang F. Scalpel can achieve better clinical outcomes compared with electric cautery in primary total knee arthroplasty: a comparison study. BMC Musculoskelet Disord 2020; 21:409. [PMID: 32600294 PMCID: PMC7325273 DOI: 10.1186/s12891-020-03457-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Accepted: 06/24/2020] [Indexed: 11/13/2022] Open
Abstract
Background Whether using the scalpel can provide better and faster recovery after the primary total knee arthroplasty (TKA) is still controversial. The aim of this research was to compare the clinical outcomes of using the scalpel and the electric cautery in primary TKA. Methods From January 2016 to December 2017, a retrospective cohort study was conducted in 313 patients who underwent unilateral primary TKA by using the scalpel (group S). During this period, we selected 313 patients who underwent unilateral primary TKA by using the electric cautery (group E) for comparison. The tourniquet time, operative time, blood loss, wound complications, visual analog score for pain, range of motion, Knee Society Score were assessed between the two groups. The Forgotten Joint Score was used to analyze the ability to forget the joint. Results There were no significant differences in tourniquet time, operative time, blood loss between the two groups (p > 0.05). In the group S, the visual analog score for pain, range of motion, Knee Society Score were found better results at 1 week, 1 month, 3 months, 6 months, 12 months and 24 months after surgery (p < 0.05). Besides, during the follow-up period, the Forgotten Joint Score was significantly higher compared with group E (p < 0.05). Conclusion In this research, the patients who underwent TKA by using the scalpel could achieve better clinical outcomes. In addition, if forgotten artificial joint after TKA was the final goal, the patients who underwent TKA by using the scalpel would acquire better quality of life.
Collapse
Affiliation(s)
- Wei Lin
- Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China
| | - Yike Dai
- Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China
| | - Jinghui Niu
- Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China
| | - Guangmin Yang
- Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China
| | - Ming Li
- Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China
| | - Fei Wang
- Department of Orthopedic Surgery, Third Hospital of Hebei Medical University, No. 139 Ziqiang Road, Shijiazhuang, 050051, Hebei, People's Republic of China.
| |
Collapse
|
34
|
Zobel SM, Morlock MM, Huber G. Fatigue strength reduction of Ti-6Al-4V titanium alloy after contact with high-frequency cauterising instruments. Med Eng Phys 2020; 81:58-67. [PMID: 32513523 DOI: 10.1016/j.medengphy.2020.05.016] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2019] [Revised: 04/30/2020] [Accepted: 05/13/2020] [Indexed: 11/30/2022]
Abstract
Contact of implants with high-frequency cauterising instruments has serious implications for patient safety. Studies have reported a possible direct connection of fatigue failure of Ti-6Al-4V implants with electrocautery contact. Such contacts were observed at the polished neck of titanium hip stems, which are subjected to high-tension loads. Evidence of electrocautery contact has also been found on a retrieved spinal fixator with a rough surface; however, no fatigue failure related to electrocautery contact has been reported thus far. The influence of the heat-affected zone caused by flashover on the mechanical behaviour of the Ti-6Al-4V titanium alloy is not yet fully understood. Then, the aim of this study was to investigate whether the polished areas of Ti-6Al-4V implants are especially susceptible to fatigue failure after electrocautery contact. Flashovers caused by electrocautery contact were induced on titanium specimens with different surface roughnesses. These specimens were subjected to cyclic loading in a four-point-bending test setup, which represented the stress resulting from physiological loading activities (~861 MPa). In this test setup, electrocautery contact was found to reduce the fatigue strength of the titanium alloy significantly-by up to 96%-as revealed from the median value of the cycles to failure. Cycles to failure showed a dependence on the flashover duration, with a flashover for 40 ms leading to fatigue fracture. Despite the lower fatigue strength of a rough polished surface in the undamaged state, it is less prone to the damaging effect of flashover than a smooth polished surface.
Collapse
Affiliation(s)
- Sebastian M Zobel
- Institute of Biomechanics, TUHH Hamburg University of Technology, Hamburg, Germany.
| | - Michael M Morlock
- Institute of Biomechanics, TUHH Hamburg University of Technology, Hamburg, Germany.
| | - Gerd Huber
- Institute of Biomechanics, TUHH Hamburg University of Technology, Hamburg, Germany.
| |
Collapse
|
35
|
Scarano A, Petrini M, Inchingolo F, Lorusso F, Amuso D. A new technique for the treatment of nasal telangiectasia using atmospheric plasma (voltaic arc dermabrasion): Postoperative pain assessment by thermal infrared imaging. J Cosmet Dermatol 2020; 19:2912-2918. [PMID: 32367634 DOI: 10.1111/jocd.13414] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2020] [Revised: 03/19/2020] [Accepted: 03/24/2020] [Indexed: 12/15/2022]
Abstract
BACKGROUND Nasal telangiectasias are superficial, small vessels in the ala nasi and nasolabial crease with a varying origin. They represent an unaesthetic condition, frustrating patients who frequently request their removal. Microsclerotherapy, electrosurgery, different types of laser therapy, needle-assisted electrocoagulation, and TRASER therapy have been described for treating this condition. AIMS The aim of this study is to describe a novel technique that removes nasal telengectiasias using voltaic arc dermabrasion (VAD). PATIENTS/METHODS Voltaic arc dermabrasion treatment was used to remove nasal telangiectasia in 23 patients. The post-treatment condition was monitored by means of photographic records and the evaluation of erythema, pain score, patient and surgeon satisfaction, and skin temperature. The timing points were 1, 4, 6 days and 1 year after treatment. RESULTS Patients referred a moderate pain during the treatment that ceased at the end of the procedure. Moderate erythema and punctiform fine crusting were present in all patients that lasted until the 6th day after treatment. No other adverse effects were observed. After 1-year, the mean patient and surgeon satisfaction scores were 2.90 and 3.00 ± 0.3, respectively. A single treatment was effective in 85% of the patients and no recurrences were recorded for one year. The skin temperature increased about 18.2 ± 3.2°C during the treatment but returned to basal values in about 20 seconds in most of the patients. CONCLUSION Voltaic arc dermabrasion treatment is a viable, easy to use, and inexpensive tool for successful nasal telangiectasia removal, with minimal post-treatment discomfort.
Collapse
Affiliation(s)
- Antonio Scarano
- Department of Medical, Oral and Biotechnological Sciences and Center for Advanced Studies and Technology (CAST), University of Chieti-Pescara, Chieti, Italy.,Research staff at Zirconia Implant Research Group (Z.I.R.G), International Academy of Ceramic Implantology, Silver Spring, MD, USA
| | - Morena Petrini
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Chieti, Italy
| | - Francesco Inchingolo
- Department of Interdisciplinary Medicine, University of Bari "Aldo Moro", Bari, Italy
| | - Felice Lorusso
- Department of Medical, Oral and Biotechnological Sciences, University of Chieti-Pescara, Chieti, Italy
| | - Domenico Amuso
- Master of Techniques of Aesthetic Medicine and Wellness, University of Palermo, Palermo, Italy
| |
Collapse
|
36
|
de Jesus AO, Matias MDP, de Arruda JAA, Aires AV, Gomes IP, Souza LN, Abreu LG, Mesquita RA. Diode laser surgery versus electrocautery in the treatment of inflammatory fibrous hyperplasia: a randomized double-blind clinical trial. Clin Oral Investig 2020; 24:4325-4334. [PMID: 32356212 DOI: 10.1007/s00784-020-03296-3] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2019] [Accepted: 04/17/2020] [Indexed: 11/28/2022]
Abstract
OBJECTIVES To compare the efficacy and safety of diode laser and electrocautery techniques for inflammatory fibrous hyperplasia (IFH) removal. MATERIALS AND METHODS In this randomized double-blind clinical trial, 40 individuals were randomly allocated to two groups: group 1 (G1) consisted of 20 individuals assigned to treatment with diode laser and group 2 (G2) consisted of 20 individuals assigned to treatment with electrocautery. The following transoperative parameters were evaluated: bleeding, temperature, and surgical technique parameters (energy deposited on tissue, flow rate, and time of incision). The postoperative parameters evaluated were as follows: pain, functional alterations (chewing, speaking), analgesic medication intake, swelling, healing of the wound area, and patient satisfaction. RESULTS Among the 40 individuals included in the study, four (two in G1 and two in G2) did not complete the entire follow-up. Therefore, 36 individuals (18 in G1 and 18 in G2) participated. Participants in G1 and in G2 had similar demographic characteristics. No difference regarding the trans- or postoperative parameters evaluated was observed between G1 and G2 (p > 0.05). Also, no difference regarding the time for healing was observed between groups. CONCLUSIONS Diode laser seems to be as effective and safe as electrocautery when applied under similar conditions for IFH removal. CLINICAL RELEVANCE IFH corresponds to 65% of the lesions observed in denture wearers. This study shows that under similar conditions diode laser is as effective and safe as electrocautery for removal of IFH.
Collapse
Affiliation(s)
- Alessandro Oliveira de Jesus
- Department of Oral Surgery and Pathology, School of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil
| | - Michelle Danielle Porto Matias
- Department of Oral Surgery and Pathology, School of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil
| | - José Alcides Almeida de Arruda
- Department of Oral Surgery and Pathology, School of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil
| | - Amanda Vieira Aires
- Department of Oral Surgery and Pathology, School of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil
| | - Isadora Pereira Gomes
- Department of Oral Surgery and Pathology, School of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil
| | - Leandro Napier Souza
- Department of Oral Surgery and Pathology, School of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil
| | - Lucas Guimarães Abreu
- Department of Child's and Adolescent's Oral Health, School of Dentistry, Universidade Federal de Minas Gerais, Av. Pres. Antônio Carlos, 6627, room 3322, Pampulha, Belo Horizonte, MG, 31270-901, Brazil.
| | - Ricardo Alves Mesquita
- Department of Oral Surgery and Pathology, School of Dentistry, Universidade Federal de Minas Gerais, Belo Horizonte, MG, Brazil
| |
Collapse
|
37
|
Abstract
OBJECTIVE To determine the impact of radiofrequency (RF) and microwave (MW) energy compared to direct cautery on metatstatic colon cancer growth. BACKGROUND Hepatic ablation with MW and RF energy creates a temperature gradient around a target site with temperatures known to create tissue injury and cell death. In contrast, direct heat application (cautery) vaporizes tissue with a higher site temperature but reduced heat gradient on surrounding tissue. We hypothesize that different energy devices create variable zones of sublethal injury that may promote tumor recurrence. To test this hypothesis we applied MW, RF, and cautery to normal murine liver with a concomitant metastatic colon cancer challenge. METHODS C57/Bl6 mice received hepatic thermal injury with MW, RF, or cautery to create a superficial 3-mm lesion immediately after intrasplenic injection of 50K MC38 colon cancer cells. Thermal imaging recorded tissue temperature during ablation and for 10 seconds after energy cessation. Hepatic tumor location and volume was determined at day 7. RESULTS Cautery demonstrated the highest maximum tissue temperatures (129°C) with more rapid return to baseline compared to MW or RF energy. All mice had metastasis at the ablation site. Mean tumor volume was significantly greater in the MW (95.3 mm; P = 0.007) and RF (55.7 mm; P = 0.015) than cautery (7.13 mm). There was no difference in volume between MW and RF energy (P = 0.2). CONCLUSIONS Hepatic thermal ablation promotes colon cancer metastasis at the injury site. MV and RF energy result in greater metastatic volume than cautery. These data suggest that the method of energy delivery promotes local metastasis.
Collapse
|
38
|
Towards a Göttingen minipig model of adult onset growth hormone deficiency: evaluation of stereotactic electrocoagulation method. Heliyon 2019; 5:e02892. [PMID: 31844758 PMCID: PMC6895662 DOI: 10.1016/j.heliyon.2019.e02892] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Revised: 09/24/2019] [Accepted: 11/18/2019] [Indexed: 01/09/2023] Open
Abstract
Background Adult onset growth hormone (GH) deficiency (AGDH) is a potentially underdiagnosed condition, caused by damage to the pituitary gland. AGHD is treated with growth hormone replacement therapy. A large variety of clinical symptoms and changes in the metabolic homeostasis can be observed and quantified. New large animal models are needed for future drug development. New method In this study, we evaluate methods for a new large non-primate animal model of GH deficiency in post pubertal Göttingen Minipigs (minipig). Lesions in the pituitary gland were made by stereotaxic monopolar thermo-coagulation guided by magnetic resonance imaging (MRI), and pituitary function was evaluated using insulin tolerance test (ITT) with measurements of growth hormone secretion induced by hypoglycemia. Results Lesions were successfully applied to the pituitary gland without any damage to surrounding tissue including the hypothalamus, which was confirmed by post-operative MRI and post mortem histology. Plasma levels of GH during ITT showed no decrease in secreted levels one week after surgery compared to levels obtained before surgery. Comparison with existing methods Compared to other GH insufficiency models, eloquent brain tissue is spared. Furthermore, alternatively to rodent models, a large animal model would allow the use of human intended equipment to evaluate disease. Using the minipig avoids social, economical and ethical issues, compared with primates. Conclusion The lesions did not remove all GH production, but proof of concept is demonstrated. In addition, the ITT is presented as a safe and efficient method to diagnose GH deficiency in minipigs.
Collapse
|
39
|
Scarano A, Carinci F, Festa F, Candotto V, Amore R, Lorusso F. Periauricular wrinkles removed with voltaic arc dermabrasion (Atmospheric Plasma technique). J Cosmet Dermatol 2019; 19:1709-1714. [DOI: 10.1111/jocd.13204] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/23/2019] [Revised: 08/22/2019] [Accepted: 10/07/2019] [Indexed: 11/30/2022]
Affiliation(s)
- Antonio Scarano
- Department of Medical, Oral and Biotechnological Sciences University of Chieti‐Pescara Chieti Italy
- Master Program in Aesthetic Medicine University of Chieti‐Pescara Chieti Italy
| | - Francesco Carinci
- Master Program in Aesthetic Medicine University of Chieti‐Pescara Chieti Italy
| | - Felice Festa
- Department of Medical, Oral and Biotechnological Sciences University of Chieti‐Pescara Chieti Italy
| | - Valentina Candotto
- Medical‑Surgical Sciences of Communication and Behavior, Section of Maxillofacial and Plastic Surgery University of Ferrara Ferrara Italy
- Department of Biomedical, Surgical and Dental Sciences University of Milan Milan Italy
| | - Roberto Amore
- Master of Techniques of Aesthetic Medicine and Wellness University of Palermo Palermo Italy
| | - Felice Lorusso
- Department of Medical, Oral and Biotechnological Sciences University of Chieti‐Pescara Chieti Italy
| |
Collapse
|
40
|
Taheri A, Green C, Mansoori P. Controlling depth of electrosurgery after curettage of skin tumors-an in vitro study. Int J Dermatol 2019; 58:1472-1476. [PMID: 31531982 DOI: 10.1111/ijd.14631] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Revised: 06/11/2019] [Accepted: 08/08/2019] [Indexed: 11/28/2022]
Abstract
BACKGROUND Depth of tissue injury in electrosurgery depends on generator power, electrode size, speed of electrode movement on tissue, and current delivery method. We sought to evaluate the depth of tissue injury associated with different methods of electrocoagulation in an effort to make electrocoagulation more reproducible. METHODS A knife-shaped electrode was used to apply an electrosurgical current to the surface of a piece of bovine liver. Different electrosurgical methods were performed. Cross sections of the liver were then studied for tissue effect. RESULTS Fulguration provided only superficial coagulation. Contact electrocoagulation and electrodesiccation using the flat side of the electrode provided significantly deeper levels of coagulation and were associated with less smoke than fulguration. Desiccation provided the deepest tissue effect. CONCLUSIONS Electrofulguration can be used for superficial tissue destruction. For deeper coagulation, a relatively larger electrode can be used in contact mode. Slower movement of the electrode on tissue in contact mode is associated with desiccation and the deepest level of tissue destruction.
Collapse
Affiliation(s)
- Arash Taheri
- Vohra Wound Physicians, Atlanta, GA, USA.,Hyperbaric Physicians of Georgia, Atlanta, GA, USA
| | | | | |
Collapse
|
41
|
Sukhikh G, Chagovets V, Wang X, Rodionov V, Kometova V, Tokareva A, Kononikhin A, Starodubtseva N, Chingin K, Chen H, Frankevich V. Combination of Low-Temperature Electrosurgical Unit and Extractive Electrospray Ionization Mass Spectrometry for Molecular Profiling and Classification of Tissues. Molecules 2019; 24:molecules24162957. [PMID: 31443190 PMCID: PMC6720730 DOI: 10.3390/molecules24162957] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 08/07/2019] [Accepted: 08/12/2019] [Indexed: 11/17/2022] Open
Abstract
Real-time molecular navigation of tissue surgeries is an important goal at present. Combination of electrosurgical units and mass spectrometry (MS) to perform accurate molecular visualization of biological tissues has been pursued by many research groups. Determination of molecular tissue composition at a particular location by surgical smoke analysis is now of increasing interest for clinical use. However, molecular analysis of surgical smoke is commonly lacking molecular specificity and is associated with significant carbonization and chemical contamination, which are mainly related to the high temperature of smoke at which many molecules become unstable. Unlike traditional electrosurgical tools, low-temperature electrosurgical units allow tissue dissection without substantial heating. Here, we show that low-temperature electrosurgical units can be used for desorption of molecules from biological tissues without thermal degradation. The use of extractive electrospray ionization technique for the ionization of desorbed molecules allowed us to obtain mass spectra of healthy and pathological tissues with high degree of differentiation. Overall, the data indicate that the described approach has potential for intraoperative use.
Collapse
Affiliation(s)
- Gennady Sukhikh
- National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I.Kulakov of the Ministry of Healthcare of Russian Federation, Moscow 117997, Russia
- Department of Obstetrics, Gynecology, Perinatology and Reproductology, First Moscow State Medical University named after I.M. Sechenov, Moscow 119991, Russia
| | - Vitaliy Chagovets
- National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I.Kulakov of the Ministry of Healthcare of Russian Federation, Moscow 117997, Russia
| | - Xinchen Wang
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang 330013, China
| | - Valeriy Rodionov
- National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I.Kulakov of the Ministry of Healthcare of Russian Federation, Moscow 117997, Russia
| | - Vlada Kometova
- National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I.Kulakov of the Ministry of Healthcare of Russian Federation, Moscow 117997, Russia
| | - Alisa Tokareva
- Moscow Institute of Physics and Technology, Moscow 141701, Russia
| | - Alexey Kononikhin
- National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I.Kulakov of the Ministry of Healthcare of Russian Federation, Moscow 117997, Russia
- Moscow Institute of Physics and Technology, Moscow 141701, Russia
| | - Natalia Starodubtseva
- National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I.Kulakov of the Ministry of Healthcare of Russian Federation, Moscow 117997, Russia
- Moscow Institute of Physics and Technology, Moscow 141701, Russia
| | - Konstantin Chingin
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang 330013, China
| | - Huanwen Chen
- Jiangxi Key Laboratory for Mass Spectrometry and Instrumentation, East China University of Technology, Nanchang 330013, China
| | - Vladimir Frankevich
- National Medical Research Center for Obstetrics, Gynecology and Perinatology named after Academician V.I.Kulakov of the Ministry of Healthcare of Russian Federation, Moscow 117997, Russia.
| |
Collapse
|
42
|
Electrosurgery and clinical applications of electrosurgical devices in gynecologic procedures. Med J Islam Repub Iran 2019; 32:90. [PMID: 30788327 PMCID: PMC6377004 DOI: 10.14196/mjiri.32.90] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2017] [Indexed: 12/12/2022] Open
Abstract
Background: Electrosurgery is widely used in reproductive related surgeries and technological advancements to improve efficacy and reduce potential complications. However, some reports have indicated lack of sufficient knowledge and training about basic principles and technical aspects of electrosurgery among obstetricians and gynecologists.
Methods: In this paper we present a summary on basic concepts and principles of electrosurgery and review the recent evidence on the use of electrosurgical devices in gynecologic procedures including endometrial ablation, gynecologic malignancies, loop electrode excision procedure (LEEP), and infertility.
Result: Considering the extensive use of these technologies in reproductive related surgeries, procedures including laparoscopy, hysteroscopy, and loop procedures further highlights the importance of more detailed training in this field. Gynecologists must learn the basics in more detail and update their knowledge on the growing body of evidence regarding the advancements of these technologies to reduce potential complications and select the most cost-effective treatment options for each patient.
Conclusion: Try to understanding the underlying biophysical principles and more in-depth familiarity with various electrosurgical devices could lead to less complications and optimize evidence-based gynecological practice.
Collapse
|
43
|
Studer N, Vizcaíno Revés N, Rytz U, Iff I. Suspected electrically induced ventricular fibrillation during thoracoscopic partial pericardectomy in two dogs. VETERINARY RECORD CASE REPORTS 2019. [DOI: 10.1136/vetreccr-2018-000750] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
Affiliation(s)
- Nicole Studer
- Department of Anaesthesiology and Pain TherapyVetsuisse FacultyUniversity of BerneBernSwitzerland
| | | | - Ulrich Rytz
- Department of Small Animal SurgeryVetsuisse FacultyUniversity of BerneBernSwitzerland
| | - Isabelle Iff
- Department of Anaesthesiology and Pain TherapyVetsuisse FacultyUniversity of BerneBernSwitzerland
| |
Collapse
|
44
|
Abstract
The aging to the upper eyelid complex includes skin laxity, resulting in rhytids, orbicularis oculi hypertrophy, and pseudohermitian of orbital fat and nowadays a high number of patients seeking cosmetic surgery. Excess and laxity of upper eyelid skin affect more than 90% of women, the impact of these problems on the patient's self-esteem can become important enough to affect quality of life in psychological and sociocultural terms.The aim of the study was to evaluate the clinical efficacy of blepharoplasty with an electrosurgical technology for treatment of skin laxity of upper eyelid, which produced a lid retraction and an elevation of the upper lid without complications.This retrospective evaluation was conducted from October 2008 to July 2015, where 80 patients (56 female and 24 male) were treated for excess and laxity of upper eyelid skin with voltaic arc dermabrasion.The outcome was that all patients displayed some aspects of tissue contraction that stretched the lax skin of the upper eyelids, resulting in cosmetic improvement.In conclusion this technique was predictable and useful to remove the laxity of upper eyelid skin minimal recurrence rates, and acceptable aesthetics.
Collapse
|
45
|
Adank MW, Fleischer JC, Dankelman J, Hendriks BHW. Real-time oncological guidance using diffuse reflectance spectroscopy in electrosurgery: the effect of coagulation on tissue discrimination. JOURNAL OF BIOMEDICAL OPTICS 2018; 23:1-10. [PMID: 30447060 DOI: 10.1117/1.jbo.23.11.115004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2018] [Accepted: 10/15/2018] [Indexed: 05/15/2023]
Abstract
In breast surgery, a lack of knowledge about what is below the tissue surface may lead to positive tumor margins and iatrogenic damage. Diffuse reflectance spectroscopy (DRS) is a spectroscopic technique that can distinguish between healthy and tumor tissue making it a suitable technology for intraoperative guidance. However, because tumor surgeries are often performed with an electrosurgical knife, the effect of a coagulated tissue layer on DRS measurements must be taken into account. It is evaluated whether real-time DRS measurements obtained with a photonic electrosurgical knife could provide useful information of tissue properties also when tissue is coagulated and cut. The size of the coagulated area is determined and the effect of its presence on DR spectra is studied using ex vivo porcine adipose and muscle tissue. A coagulated tissue layer with a depth of 0.1 to 0.4 mm is observed after coagulating muscle with an electrosurgical knife. The results show that the effect of coagulating adipose tissue is negligible. Using the fat/water ratio's calculated from the measured spectra of the photonic electrosurgical knife, it was possible to determine the distance from the instrument tip to a tissue transition during cutting. In conclusion, the photonic electrosurgical knife can determine tissue properties of coagulated and cut tissue and has, therefore, the potential to provide real-time feedback about the presence of breast tumor margins during cutting, helping surgeons to establish negative margins and improve patient outcome.
Collapse
Affiliation(s)
- Maartje W Adank
- Delft University of Technology, Biomechanical Engineering Department, Delft, The Netherlands
| | - Julie C Fleischer
- Delft University of Technology, Biomechanical Engineering Department, Delft, The Netherlands
| | - Jenny Dankelman
- Delft University of Technology, Biomechanical Engineering Department, Delft, The Netherlands
| | - Benno H W Hendriks
- Delft University of Technology, Biomechanical Engineering Department, Delft, The Netherlands
- Philips Research, In-Body Systems Department, Eindhoven, The Netherlands
| |
Collapse
|
46
|
Electric cautery does not reduce blood loss in primary total knee arthroplasty compared with scalpel only surgery a double-blinded randomized controlled trial. INTERNATIONAL ORTHOPAEDICS 2018; 42:2755-2760. [PMID: 29968137 DOI: 10.1007/s00264-018-4048-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/18/2018] [Accepted: 06/25/2018] [Indexed: 10/28/2022]
Abstract
PURPOSE The purpose of this study was to systematically compare blood loss between the electric cautery and scalpel used in primary total knee arthroplasty (TKA). METHODS We performed a double-blind trial randomizing osteoarthritic knee patients undergoing unilateral TKA done by either using scalpel (group S) or cautery (group C). Primary outcomes were total blood loss calculated from maximum haemoglobin drop and blood loss collected in drain. Secondary outcomes were systemic inflammatory response (serum C-reactive protein), wound complications, and functional outcomes assessed over three months. RESULTS A total of 80 patients were recruited. Group S had similar calculated total blood loss compared to group C (1070 (S) vs 1128 (C) mL, 95% CI - 219 to 103, p = 0.47). There was no difference in the mean drain-collected blood loss between the two groups (443 (S) vs 486 (C) mL, 95% CI - 128 to 47, p = 0.36). Group C had higher serum C-reactive protein level at 48 hours after TKA compare to group S (105 vs 140 mg/dL, 95% CI - 66 to - 4, p = 0.03). Wound complications and functional outcomes at three months were also similar between the two groups. CONCLUSIONS Using electric cautery does not reduce total blood loss as we thought it would be in primary TKA compare to scalpel only surgery and it is also associated with a greater systemic inflammatory response. Cautery used in TKA which operated under tourniquet may not be worthwhile for the risk of hazardous smoke and the increasing cost.
Collapse
|
47
|
Sakes A, Hovland K, Smit G, Geraedts J, Breedveld P. Design of a Novel Three-Dimensional-Printed Two Degrees-of-Freedom Steerable Electrosurgical Grasper for Minimally Invasive Surgery. J Med Device 2018. [DOI: 10.1115/1.4038561] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022] Open
Abstract
In current bipolar electrosurgical instruments, a high frequency electrical sinusoidal wave is passed through the patient's body from an active electrode to the return electrode to cut, coagulate, or desiccate tissues. Even though current bipolar electrosurgical instruments have proven effective in minimizing blood loss, advancement is needed to allow for improved dexterity and adaptability. With current advances in three-dimensional (3D)-print processes and its integration in the medical field, it has become possible to manufacture patient-and operation-specific instruments. In this study, we introduce the first 3D-printed steerable bipolar grasper (◻ 5 mm) for use in minimal invasive surgery. The grasper significantly improves dexterity by the addition of two planar joints allowing for ±65 deg for sideways and ±85 deg for up- and downward movement. The joints enable a significantly higher bending stiffness, 4.0 N/mm for joint 1 and 4.4 N/mm for joint 2, than that of currently available steerable instruments. The tip consists of two metallic movable jaws that can be opened and closed with angles up to 170 deg and allows for grasping and coagulating of tissues; reaching tissue temperatures of over 75 °C for an activation time of ∼5 s, respectively. In order to actuate the joint, tip, and electrosurgical system, as well as to tension the steering cables, a ring handle was designed. In summary, the 3D-printed steerable bipolar grasper provides the surgeon with electrosurgical capabilities, improved dexterity, improved stiffness, and the versatility that is needed to provide patient- and operation-specific care.
Collapse
Affiliation(s)
- Aimée Sakes
- Department BioMechanical Engineering, Faculty Mechanical, Maritime, and Materials Engineering, Delft University of Technology, Mekelweg 2, Delft 2628 CD, The Netherlands e-mail:
| | - Kevin Hovland
- Department BioMechanical Engineering, Faculty Mechanical, Maritime, and Materials Engineering, Delft University of Technology, Mekelweg 2, Delft 2628 CD, The Netherlands e-mail:
| | - Gerwin Smit
- Department BioMechanical Engineering, Faculty Mechanical, Maritime, and Materials Engineering, Delft University of Technology, Mekelweg 2, Delft 2628 CD, The Netherlands e-mail:
| | - Jo Geraedts
- Department Design Engineering, Faculty Industrial Design Engineering, Delft University of Technology, Mekelweg 2, Delft 2628 CD, The Netherlands e-mail:
| | - Paul Breedveld
- Department BioMechanical Engineering, Faculty Mechanical, Maritime, and Materials Engineering, Delft University of Technology, Mekelweg 2, Delft 2628 CD, The Netherlands e-mail:
| |
Collapse
|
48
|
Cho SB, Na J, Zheng Z, Lim JM, Kang JS, Lee JH, Lee SE. In vivo skin reactions from pulsed-type, bipolar, alternating current radiofrequency treatment using invasive noninsulated electrodes. Skin Res Technol 2018; 24:318-325. [PMID: 29368439 DOI: 10.1111/srt.12433] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 01/01/2018] [Indexed: 01/29/2023]
Abstract
BACKGROUND Bipolar, alternating current radiofrequency (RF) conduction using invasive noninsulated electrodes consecutively generates independent tissue coagulation around each electrode and then, the converged coagulation columns. METHODS Two pulsed-type RF models at the on-time pulse width/pulse pack of 30 and 40 milliseconds were designed to amplify the early stage of RF-induced tissue reaction using hairless mouse skin in vivo. Then, structural and ultrastructural changes were evaluated in hairless mouse skin samples at baseline and immediately 1 day, 3 days, 7 days, and 14 days after treatment. RESULTS Immediately after pulsed-RF treatment, a few chrysanthemum-like zones of electrothermal coagulation and hypereosinophilic collagen fibers were found in the dermis and dermo-subcutaneous fat junction. Histochemical staining for periodic acid-Schiff and immunohistochemical staining for type IV collagen revealed marked thickening of basement membranes. Transmission electron microscopy demonstrated that pulsed-RF treatment resulted in higher electron-dense and remarkably thicker lamina densa, as well as increases in anchoring fibrils, compared with untreated control specimens. Furthermore, CD31-positive blood vessels were smaller in size with a slit-like luminal appearance, without excessive damage to endothelial cells. CONCLUSION Our data indicated that pulse-type, bipolar RF energy induces structural and ultrastructural changes in basement membranes and vascular components in hairless mouse skin.
Collapse
Affiliation(s)
- S B Cho
- Department of Dermatology and Cutaneous Biology Research Center, International St. Mary's Hospital, Catholic Kwandong University College of Medicine, Incheon, Korea.,Kangskin Dermatology Clinic, Seoul, Korea
| | - J Na
- Department of Anatomy, Soonchunhyang University College of Medicine, Cheonan, Korea
| | - Z Zheng
- Department of Dermatology and Cutaneous Biology Research Center, International St. Mary's Hospital, Catholic Kwandong University College of Medicine, Incheon, Korea.,Department of Dermatology, Yanbian University Hospital, Yanji, China
| | - J M Lim
- Department of Dermatology and Cutaneous Biology Research Institute, Yonsei University College of Medicine, Seoul, Korea
| | - J-S Kang
- Kangskin Dermatology Clinic, Seoul, Korea
| | - J H Lee
- Department of Dermatology and Cutaneous Biology Research Institute, Yonsei University College of Medicine, Seoul, Korea
| | - S E Lee
- Department of Dermatology and Cutaneous Biology Research Institute, Yonsei University College of Medicine, Seoul, Korea
| |
Collapse
|
49
|
Ishida T, Toyonaga T, Ohara Y, Nakashige T, Kitamura Y, Ariyoshi R, Takihara H, Baba S, Yoshizaki T, Kawara F, Tanaka S, Morita Y, Umegaki E, Hoshi N, Azuma T. Efficacy of forced coagulation with low high-frequency power setting during endoscopic submucosal dissection. World J Gastroenterol 2017; 23:5422-5430. [PMID: 28839443 PMCID: PMC5550792 DOI: 10.3748/wjg.v23.i29.5422] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 01/27/2017] [Revised: 03/31/2017] [Accepted: 06/19/2017] [Indexed: 02/07/2023] Open
Abstract
AIM To investigated the hemostatic ability of the S and F1-10 methods in clinical and ex vivo studies.
METHODS The hemostatic abilities of the two methods were analyzed retrospectively in all six gastric endoscopic submucosal dissection cases. The treated vessel diameter, compressed vessel frequency, and bleeding frequency after cutting the vessels were noted by the recorded videos. The coagulation mechanism of the two power settings was evaluated using the data recording program and histological examination on macro- and microscopic levels in the ex vivo experiments using porcine tissues.
RESULTS F1-10 method showed a significantly better hemostatic ability for vessels ≥ 2 mm in diameter and a trend of overall better coagulation effect, evaluated by the bleeding rate after cutting the vessels. F1-10 method could sustain electrical current longer and effectively coagulate the tissue wider and deeper than the S method in the porcine model.
CONCLUSION F1-10 method is suggested to achieve a stronger hemostatic effect than the S method in clinical procedures and ex vivo models.
Collapse
|
50
|
Evaluation Effectiveness of the Voltaic Arc Dermabrasion in Perioral Rhytides Eradication. J Craniofac Surg 2017; 27:1205-8. [PMID: 27300456 DOI: 10.1097/scs.0000000000002714] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
Perioral rhytides affect more than 90% of women, the impact of these problems on the patient's self-esteem can become important enough to affect quality of life in psychological and sociocultural terms. Basic science shows that skin rhytides are related to loss in quantity and function of dermal collagen fibers. An electrosurgical technology was used in this study for treatment of perioral rhytides. The authors treated 34 patients (26 women and 8 men) for perioral rhytides with voltaic arc dermabrasion technique. Patient ages ranged between 30 and 65 years and the majority (90%) of these perioral areas had class II and III wrinkle scores. Voltaic arc dermabrasion was used to remove the keratinized layer for point perioral area. Treatments are minimally painful and in the authors' experience require no anesthesia. No discomfort should be expected once the voltaic arc dermabrasion treatment is concluded. The perioral dermis appears as a pale, erythematous, dull surface. Bleeding is not seen unless excessive abrading occurs with the saline-moistened gauze. No hyperpigmentation, hypopigmentation, erythema, ecchymosis, pain, itching, outbreaks of herpes, infectious processes, and scarring were observed. All patients monitored for fine perioral rhytides showed a reduction in the treated area. Since skin-specific quality of life was significantly improved after "voltaic arc" treatment, this therapy can be recommended for patients with perioral rhytides skin wishing to improve their appearance.
Collapse
|