1
|
Vamos M, Zsigmond EJ, Biffi M, Gausz FD, Keller N, Kupo P, Szili-Torok T, Ziacchi M, Benz AP, Spittler R, Vagvolgyi A. Efficacy and safety of the subcutaneous implantable cardioverter-defibrillator in patients with and without obesity: A meta-analysis. Heart Rhythm 2025; 22:375-387. [PMID: 39019386 DOI: 10.1016/j.hrthm.2024.07.021] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/03/2024] [Revised: 06/25/2024] [Accepted: 07/11/2024] [Indexed: 07/19/2024]
Abstract
BACKGROUND The subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as an alternative to transvenous systems for prevention of sudden cardiac death. However, concerns have been raised regarding its efficacy and safety in obese individuals. OBJECTIVE The purpose of this study was to perform a meta-analysis to evaluate the efficacy and safety of the S-ICD in patients with obesity by assessing the relationship between body mass index (BMI) and clinical outcomes. METHODS A comprehensive search of multiple databases was conducted for English-language peer-reviewed studies reporting clinical outcomes in S-ICD recipients with (BMI ≥30 kg/m2) and without obesity (BMI <30 kg/m2). Data on preimplantation screening failure, defibrillation testing, complications, appropriate and inappropriate shocks, and survival were analyzed using standard, random-effects, meta-analytical techniques. RESULTS Twenty-nine studies involving 20,486 patients were included. There was no statistically significant difference in mean BMI values of patients with failed or successful preimplantation screening (mean difference -0.60 kg/m2; 95% confidence interval [CI] -2.06 to 0.86). Obesity was associated with higher rates of failed defibrillation testing at ≤65 J (odds ratio [OR] 2.16; 95% CI 1.39-3.35), and malpositioning/suboptimal positioning occurred more frequently in obese compared to nonobese patients (OR 3.37; 95% CI 1.76-6.44). Increased BMI as a continuous variable (per increase in 1 kg/m2 BMI) was associated with elevated defibrillation thresholds (OR 1.05; 95% CI 1.03-1.08); higher risk of complications (hazard ratio [HR] 1.04; 95% CI 1.02-1.05); a trend toward an increased number of appropriate shocks (HR 1.02; 95% CI 1.00-1.04); and no significant increase in the risk of inappropriate shocks (HR 1.01; 95% CI 0.99-1.03). CONCLUSION This meta-analysis underscores the importance of considering obesity in S-ICD implantation decisions. Although S-ICD remains effective in obese patients, attention to potential technical challenges and higher complication rates is warranted.
Collapse
Affiliation(s)
- Mate Vamos
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, Szeged, Hungary.
| | - Elod-Janos Zsigmond
- Central Hospital of Northern Pest-Military Hospital, Budapest, Hungary; Doctoral School of Clinical Medicine, University of Szeged, Szeged, Hungary
| | - Mauro Biffi
- Department of Cardiology, IRCCS Azienda Ospedaliero Universitaria di Bologna, Bologna, Italy
| | - Flora Diana Gausz
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, Szeged, Hungary
| | - Nora Keller
- Central Pharmacy, Albert Szent-Györgyi Medical Centre, University of Szeged, Szeged, Hungary
| | - Peter Kupo
- Heart Institute, Medical School, University of Pecs, Pecs, Hungary
| | - Tamas Szili-Torok
- Cardiac Electrophysiology Division, Cardiology Center, Department of Internal Medicine, University of Szeged, Szeged, Hungary
| | - Matteo Ziacchi
- Department of Cardiology, IRCCS Azienda Ospedaliero Universitaria di Bologna, Bologna, Italy
| | - Alexander P Benz
- Department of Cardiology, University Medical Center Mainz, Johannes Gutenberg-University, Mainz, Germany; Population Health Research Institute, McMaster University, Hamilton, Canada
| | - Raphael Spittler
- Department of Cardiology, University Medical Center Mainz, Johannes Gutenberg-University, Mainz, Germany
| | - Anna Vagvolgyi
- Endocrinology and Diabetology Center, Department of Internal Medicine, University of Szeged, Szeged, Hungary
| |
Collapse
|
2
|
Schulman PM, Stecker EC. Perioperative Implantable Cardioverter Defibrillator Management: The Confusion and Controversary Continues. A A Pract 2025; 19:e01914. [PMID: 39898543 DOI: 10.1213/xaa.0000000000001914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2025]
Affiliation(s)
- Peter M Schulman
- From the Department of Anesthesiology and Perioperative Medicine, Oregon Health & Science University, Portland, Oregon
| | - Eric C Stecker
- Department of Medicine, Division of Cardiology, Knight Cardiovascular Institute, Oregon Health & Science University, Portland, Oregon
| |
Collapse
|
3
|
Carroll SL, Mondésert B, Krahn AD, Bashir JG, Fisher K, Nair K, Healey JS. Device-specific quality of life: results from the ATLAS trial-avoid transvenous leads in appropriate subjects. Eur J Cardiovasc Nurs 2024; 23:877-885. [PMID: 38695087 DOI: 10.1093/eurjcn/zvae067] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/01/2024] [Revised: 04/05/2024] [Accepted: 04/28/2024] [Indexed: 12/17/2024]
Abstract
AIMS Patient-reported outcomes (PROs) provide important insights into patients' acceptance of their medical devices. Avoid Transvenous Leads in Appropriate Subjects (ATLAS), a randomized, multi-centre, open-label clinical trial, recently reported fewer perioperative complications in subcutaneous implantable cardioverter defibrillator (S-ICD) compared with transvenous ICD (TV-ICD) patients. This study reports PROs, including device-specific and generic quality of life (QOL), from the ATLAS trial. METHODS AND RESULTS Device-specific QOL was the primary PRO using the Florida Patient Acceptance Survey (FPAS) at 1 and 6 months' post-implantation. Secondary outcomes included generic QOL using the Medical Outcomes Survey (SF-36) pre-implant and 6 months' post-implantation. The FPAS and SF-36 were analysed using analysis of covariance. Pain measured using a Numeric Rating Scale, at 1 and 6 months, anaesthetic, body mass index, and within/between differences were analysed using descriptive statistics and mixed-effects linear models. Of the 503 patients randomized in ATLAS, 404 had complete FPAS data to be included in this analysis. Participant characteristics were balanced. There were no significant differences between S-ICD and TV-ICD for the FPAS or SF-36, across time points. Mean total FPAS scores increased from 73.73 (16.09) to 77.05 (16.13) and 74.43 (15.35) to 78.25 (15.88) for S-ICD and TV-ICD, respectively (P < 0.001). Patient-reported outcomes suggested that both devices were associated with good QOL. CONCLUSION Device-specific and generic QOL were similar between S-ICD and TV-ICD groups up to 6 months' post-implantation, indicating that regardless of device type, both groups reported good device-specific QOL in ATLAS patients. Subcutaneous ICD patients reported higher pain scores at implant, but pain decreased by 6 months. The findings offer evidence that can be included during shared decision-making. The inclusion of patient partners in ATLAS provided an opportunity to measure PROs that were deemed important to patients. REGISTRATION ClinialTrials.gov: NCT02881255.
Collapse
Affiliation(s)
- Sandra L Carroll
- School of Nursing, McMaster University, 1280 Main Street West, HSC 2J17, Hamilton, ON, Canada L8S 4K1
- Population Health Research Institute, 237 Barton Street East, Hamilton, ON L8L 2X2, Canada
| | - Blandine Mondésert
- Montreal Heart Institute, 5000 Rue Bélanger, Montréal, QC H1T 1C8, Canada
| | - Andrew D Krahn
- Division of Cardiology, University of British Columbia, 2775 Laurel St, 9th Floor, Vancouver, BC V5Z 1M9, Canada
| | - Jamil G Bashir
- Faculty of Medicine, University of British Columbia, 317-2194 Health Sciences Mall, Vancouver, BC V6T 1Z3, Canada
| | - Kathryn Fisher
- School of Nursing, McMaster University, 1280 Main Street West, HSC 2J17, Hamilton, ON, Canada L8S 4K1
| | - Kalpana Nair
- School of Nursing, McMaster University, 1280 Main Street West, HSC 2J17, Hamilton, ON, Canada L8S 4K1
| | - Jeff S Healey
- Population Health Research Institute, 237 Barton Street East, Hamilton, ON L8L 2X2, Canada
| |
Collapse
|
4
|
Kloppe A, Winter J, Prull M, Aweimer A, El-Battrawy I, Hanefeld C, O'Connor S, Mügge A, Schiedat F. Subcutaneous cardioverter defibrillator implanted intermuscularly in patients with end-stage renal disease requiring hemodialysis: 5-year follow-up. J Interv Card Electrophysiol 2024:10.1007/s10840-024-01767-1. [PMID: 38383674 DOI: 10.1007/s10840-024-01767-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 11/15/2023] [Accepted: 02/01/2024] [Indexed: 02/23/2024]
Abstract
BACKGROUND The aim of the present study was to evaluate the long-term safety and effectiveness of the subcutaneous implantable cardioverter defibrillator (S-ICD) when implanted intermuscularly in patients with end-stage renal disease and hemodialysis. METHODS This study is a retrospective analysis of 21 consecutive patients implanted with S-ICDs at three experienced centers in Germany with comorbid renal insufficiency requiring hemodialysis, as well as being at risk of sudden cardiac death. The S-ICD was placed intermuscularly in all patients. Follow-ups (FUs) were performed every 6 months. RESULTS The mean ± standard deviation FU duration was 60.0 ± 11.4 months, with a range of 39 to 78 months. There were no deaths due to arrhythmia, or device-associated infections and complications. Four patients (19.1%) died during FU due to respiratory insufficiency during dialysis, systolic heart failure, septic infection of the urogenital tract, and colorectal cancer, respectively. There were six non-device-related hospitalizations with a duration of 12.7 ± 5.1 days and a hospitalization rate of 4.1 per 100 patient years. CONCLUSIONS In the long-term FU of this small population of seriously compromised hemodialysis patients at risk of sudden cardiac death, the intermuscularly implanted S-ICD system was safe and effective. No arrhythmic complications, device-associated infections, or complications compromised survival. These data are encouraging and support testing in a larger group of similarly compromised patients.
Collapse
Affiliation(s)
- Axel Kloppe
- Department of Cardiology, Intensive Medicine and Angiology, Marienhospital Gelsenkirchen, Academic Hospital of the Ruhr University Bochum, Virchowstraße 122, 45886, Gelsenkirchen, Germany
- Department of Cardiology and Angiology, University Hospital Bergmannsheil Bochum, Ruhr University Bochum, Bochum, Germany
| | - Joachim Winter
- Department of Cardiovascular Surgery, Heinrich Heine University, Dusseldorf, Germany
| | - Magnus Prull
- Department of Cardiology, Augusta Hospital Bochum, Bochum, Germany
| | - Assem Aweimer
- Department of Cardiology and Angiology, University Hospital Bergmannsheil Bochum, Ruhr University Bochum, Bochum, Germany
| | - Ibrahim El-Battrawy
- Department of Cardiology and Angiology, University Hospital Bergmannsheil Bochum, Ruhr University Bochum, Bochum, Germany
- Department of Molecular and Experimental Cardiology, Institut Für Forschung Und Lehre (IFL), Ruhr University Bochum, Bochum, Germany
| | - Christoph Hanefeld
- Department of Cardiology, Katholische Kliniken Bochum, Ruhr University Bochum, Bochum, Germany
| | - Stephen O'Connor
- Department of Biomedical Engineering, City, University of London, London, UK
| | - Andreas Mügge
- Department of Cardiology and Angiology, University Hospital Bergmannsheil Bochum, Ruhr University Bochum, Bochum, Germany
- Department of Cardiology, Katholische Kliniken Bochum, Ruhr University Bochum, Bochum, Germany
| | - Fabian Schiedat
- Department of Cardiology, Intensive Medicine and Angiology, Marienhospital Gelsenkirchen, Academic Hospital of the Ruhr University Bochum, Virchowstraße 122, 45886, Gelsenkirchen, Germany.
- Department of Cardiology and Angiology, University Hospital Bergmannsheil Bochum, Ruhr University Bochum, Bochum, Germany.
| |
Collapse
|
5
|
Coletta F, Schettino F, Tomasello A, Sala C, Pisanti M, Villani R. Serratus anterior plane block and postoperative pain control in obese patients undergoing S-ICD implantation: A case series and literature analysis. Clin Case Rep 2024; 12:e8374. [PMID: 38173891 PMCID: PMC10762328 DOI: 10.1002/ccr3.8374] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2023] [Revised: 11/01/2023] [Accepted: 11/27/2023] [Indexed: 01/05/2024] Open
Abstract
We report five case series of obese patients with severe left ventricular ejection fraction impairment undergoing Serratus Anterior Plane Block during S-ICD Implantation. This anesthesia approach has a reduced impact on the patient's hemodynamics and adequately manages postprocedural pain. Abstract Subcutaneous implantable cardioverter-defibrillator (S-ICD) procedures are frequently performed under analgosedation or general anesthesia, leading to prolonged postoperative hospital stays and increased costs. This anesthetic technique may also have a greater hemodynamic impact, particularly in obese and cardiac patients. However, an alternative anesthetic technique can be employed: ultrasound-guided serratus anterior plane block (US-SAPB). We analyzed the anesthetic clinical course in 5 patients, 3 males and 2 females, who were obese (BMI ≥ 30) and underwent S-ICD implantation for primary prevention using a two-incision intermuscular technique and ultrasound-guided serratus anterior plane block. All patients had a left ventricular ejection fraction less than or equal to 35%. It significantly facilitated pain control during the procedure and, especially, in the postoperative phase. However, the data available in the literature are mostly derived from case reports and small comparative studies. Therefore, further studies with a larger sample size and direct comparison with general anesthesia or deep sedation are needed.
Collapse
Affiliation(s)
- Francesco Coletta
- Anesthesia, Emergency and Burn Intensive Care Unit, Emergency and Acceptance DepartmentCardarelli HospitalNaplesItaly
| | - Francesca Schettino
- Anesthesia, Emergency and Burn Intensive Care Unit, Emergency and Acceptance DepartmentCardarelli HospitalNaplesItaly
| | - Antonio Tomasello
- Anesthesia, Emergency and Burn Intensive Care Unit, Emergency and Acceptance DepartmentCardarelli HospitalNaplesItaly
| | - Crescenzo Sala
- Anesthesia, Emergency and Burn Intensive Care Unit, Emergency and Acceptance DepartmentCardarelli HospitalNaplesItaly
| | - Massimo Pisanti
- Anesthesia, Emergency and Burn Intensive Care Unit, Emergency and Acceptance DepartmentCardarelli HospitalNaplesItaly
| | - Romolo Villani
- Anesthesia, Emergency and Burn Intensive Care Unit, Emergency and Acceptance DepartmentCardarelli HospitalNaplesItaly
| |
Collapse
|
6
|
Guarracini F, Preda A, Bonvicini E, Coser A, Martin M, Quintarelli S, Gigli L, Baroni M, Vargiu S, Varrenti M, Forleo GB, Mazzone P, Bonmassari R, Marini M, Droghetti A. Subcutaneous Implantable Cardioverter Defibrillator: A Contemporary Overview. Life (Basel) 2023; 13:1652. [PMID: 37629509 PMCID: PMC10455445 DOI: 10.3390/life13081652] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 07/23/2023] [Accepted: 07/25/2023] [Indexed: 08/27/2023] Open
Abstract
The difference between subcutaneous implantable cardioverter defibrillators (S-ICDs) and transvenous ICDs (TV-ICDs) concerns a whole extra thoracic implantation, including a defibrillator coil and pulse generator, without endovascular components. The improved safety profile has allowed the S-ICD to be rapidly taken up, especially among younger patients. Reports of its role in different cardiac diseases at high risk of SCD such as hypertrophic and arrhythmic cardiomyopathies, as well as channelopathies, is increasing. S-ICDs show comparable efficacy, reliability, and safety outcomes compared to TV-ICD. However, some technical issues (i.e., the inability to perform anti-bradycardia pacing) strongly limit the employment of S-ICDs. Therefore, it still remains only an alternative to the traditional ICD thus far. This review aims to provide a contemporary overview of the role of S-ICDs compared to TV-ICDs in clinical practice, including technical aspects regarding device manufacture and implantation techniques. Newer outlooks and future perspectives of S-ICDs are also brought up to date.
Collapse
Affiliation(s)
- Fabrizio Guarracini
- Department of Cardiology, S. Chiara Hospital, 38122 Trento, Italy; (E.B.); (A.C.); (M.M.); (S.Q.); (R.B.); (M.M.)
| | - Alberto Preda
- Electrophysiology Unit, Cardio-Thoraco-Vascular Department, ASST Grande Ospedale Metropolitano Niguarda, 20162 Milan, Italy; (A.P.); (L.G.); (M.B.); (S.V.); (M.V.); (P.M.)
| | - Eleonora Bonvicini
- Department of Cardiology, S. Chiara Hospital, 38122 Trento, Italy; (E.B.); (A.C.); (M.M.); (S.Q.); (R.B.); (M.M.)
| | - Alessio Coser
- Department of Cardiology, S. Chiara Hospital, 38122 Trento, Italy; (E.B.); (A.C.); (M.M.); (S.Q.); (R.B.); (M.M.)
| | - Marta Martin
- Department of Cardiology, S. Chiara Hospital, 38122 Trento, Italy; (E.B.); (A.C.); (M.M.); (S.Q.); (R.B.); (M.M.)
| | - Silvia Quintarelli
- Department of Cardiology, S. Chiara Hospital, 38122 Trento, Italy; (E.B.); (A.C.); (M.M.); (S.Q.); (R.B.); (M.M.)
| | - Lorenzo Gigli
- Electrophysiology Unit, Cardio-Thoraco-Vascular Department, ASST Grande Ospedale Metropolitano Niguarda, 20162 Milan, Italy; (A.P.); (L.G.); (M.B.); (S.V.); (M.V.); (P.M.)
| | - Matteo Baroni
- Electrophysiology Unit, Cardio-Thoraco-Vascular Department, ASST Grande Ospedale Metropolitano Niguarda, 20162 Milan, Italy; (A.P.); (L.G.); (M.B.); (S.V.); (M.V.); (P.M.)
| | - Sara Vargiu
- Electrophysiology Unit, Cardio-Thoraco-Vascular Department, ASST Grande Ospedale Metropolitano Niguarda, 20162 Milan, Italy; (A.P.); (L.G.); (M.B.); (S.V.); (M.V.); (P.M.)
| | - Marisa Varrenti
- Electrophysiology Unit, Cardio-Thoraco-Vascular Department, ASST Grande Ospedale Metropolitano Niguarda, 20162 Milan, Italy; (A.P.); (L.G.); (M.B.); (S.V.); (M.V.); (P.M.)
| | - Giovanni Battista Forleo
- Department of Thoracic Surgery, Candiolo Cancer Institute, FPO-IRCCS, Candiolo, 10060 Turin, Italy;
| | - Patrizio Mazzone
- Electrophysiology Unit, Cardio-Thoraco-Vascular Department, ASST Grande Ospedale Metropolitano Niguarda, 20162 Milan, Italy; (A.P.); (L.G.); (M.B.); (S.V.); (M.V.); (P.M.)
| | - Roberto Bonmassari
- Department of Cardiology, S. Chiara Hospital, 38122 Trento, Italy; (E.B.); (A.C.); (M.M.); (S.Q.); (R.B.); (M.M.)
| | - Massimiliano Marini
- Department of Cardiology, S. Chiara Hospital, 38122 Trento, Italy; (E.B.); (A.C.); (M.M.); (S.Q.); (R.B.); (M.M.)
| | - Andrea Droghetti
- Cardiology Unit, Luigi Sacco University Hospital, 20157 Milan, Italy;
| |
Collapse
|
7
|
Vio R, Forlin E, Čulić V, Themistoclakis S, Proietti R, China P. Systematic Review on S-ICD Lead Extraction. J Clin Med 2023; 12:3710. [PMID: 37297905 PMCID: PMC10254059 DOI: 10.3390/jcm12113710] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/24/2023] [Revised: 05/20/2023] [Accepted: 05/25/2023] [Indexed: 06/12/2023] Open
Abstract
BACKGROUND AND PURPOSE Subcutaneous implantable cardioverter defibrillators (S-ICDs) have emerged in recent years as a valid alternative to traditional transvenous ICDs (TV-ICDs). Therefore, the number of S-ICD implantations is rising, leading to a consequent increase in S-ICD-related complications sometimes requiring complete device removal. Thus, the aim of this systematic review is to gather all the available literature on S-ICD lead extraction (SLE), with particular reference to the type of indication, techniques, complications and success rate. METHODS Studies were identified by searching electronic databases (Medline via PubMed, Scopus and Web of Science) from inception to 21 November 2022. The search strategy adopted was developed using the following key words: subcutaneous, S-ICD, defibrillator, ICD, extraction, explantation. Studies were included if they met both of the following criteria: (1) inclusion of patients with S-ICD; (2) inclusion of patients who underwent SLE. RESULTS Our literature search identified 238 references. Based on the abstract evaluation, 38 of these citations were considered potentially eligible for inclusion, and their full texts were analyzed. We excluded 8 of these studies because no SLE was performed. Eventually, 30 studies were included, with 207 patients who underwent SLE. Overall, the majority of SLEs were performed for non-infective causes (59.90%). Infection of the device (affecting either the lead or the pocket) was the cause of SLE in 38.65% of cases. Indication data were not available in 3/207 cases. The mean dwelling time was 14 months. SLEs were performed using manual traction or with the aid of a tool designed for transvenous lead extraction (TLE), including either a rotational or non-powered mechanical dilator sheath. CONCLUSIONS SLE is performed mainly for non-infective causes. Techniques vary greatly across different studies. Dedicated tools for SLE might be developed in the future and standard approaches should be defined. In the meantime, authors are encouraged to share their experience and data to further refine the existing variegated approaches.
Collapse
Affiliation(s)
- Riccardo Vio
- Department of Cardiothoracic, Vascular Medicine and Intensive Care, Dell’Angelo Hospital, 30174 Mestre-Venice, Italy; (R.V.); (E.F.); (S.T.); (P.C.)
| | - Enrico Forlin
- Department of Cardiothoracic, Vascular Medicine and Intensive Care, Dell’Angelo Hospital, 30174 Mestre-Venice, Italy; (R.V.); (E.F.); (S.T.); (P.C.)
- Department of Cardiac, Thoracic and Vascular Sciences and Public Health, University of Padua, 35128 Padua, Italy
| | - Viktor Čulić
- School of Medicine, University of Split, 21000 Split, Croatia;
- Department of Cardiology and Angiology, University Hospital Centre Split, 21000 Split, Croatia
| | - Sakis Themistoclakis
- Department of Cardiothoracic, Vascular Medicine and Intensive Care, Dell’Angelo Hospital, 30174 Mestre-Venice, Italy; (R.V.); (E.F.); (S.T.); (P.C.)
| | - Riccardo Proietti
- Liverpool Centre for Cardiovascular Science, University of Liverpool and Liverpool Heart and Chest Hospital, Liverpool L8 7TX, UK
| | - Paolo China
- Department of Cardiothoracic, Vascular Medicine and Intensive Care, Dell’Angelo Hospital, 30174 Mestre-Venice, Italy; (R.V.); (E.F.); (S.T.); (P.C.)
| |
Collapse
|
8
|
Khan Z, Sethumadhavan D, Rayner T, Kyaw S. Inappropriate Shocks With Subcutaneous Implantable Cardioverter-Defibrillator in a Young Patient: A Case Report. Cureus 2023; 15:e34492. [PMID: 36874347 PMCID: PMC9983290 DOI: 10.7759/cureus.34492] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 02/01/2023] [Indexed: 02/04/2023] Open
Abstract
Implantable cardioverter-defibrillators (ICDs) are increasingly used for the primary and secondary prevention of sudden cardiac death (SCD). Currently, transvenous (TV) and subcutaneous (S) ICDs are the two different types used. Preservation of central venous vasculature, no risk of vascular or myocardial injury during implant, easier explantation, and lower risk of systemic infections have driven the increased use of S-ICDs. The shocks delivered by ICDs for non-life-threatening arrhythmias or because of oversensing T waves or noise are known as inappropriate shocks. Here, we present the case of a 33-year-old man who had an S-ICD implanted in 2019 for hypertrophic cardiomyopathy. He had a TV-ICD implanted in 2010 which was explanted in 2013 due to infective endocarditis, and the patient underwent a mechanical mitral valve replacement. He was at intermediate risk for SCD over the next five years. He had an S-ICD implanted in 2019 and had never received any shock before. Electrocardiogram showed normal sinus rhythm, left axis deviation, QRS 110 ms, hyperacute T waves in inferior leads, and T-wave inversion in lateral leads. He then began experiencing inappropriate shocks three years after S-ICD placement due to a drop in R wave amplitude secondary to noise oversensing in October 2022. Despite reprogramming the device from the primary vector to an alternate vector, the patient had further inappropriate shocks two months later due to noise oversensing. The patient was discussed in a multidisciplinary team meeting and the S-ICD was explanted according to the patient's wishes and a loop recorder was implanted.
Collapse
Affiliation(s)
- Zahid Khan
- Acute Medicine, Mid and South Essex NHS Foundation Trust, Southend-on-Sea, GBR.,Cardiology, Barts Heart Centre, London, GBR.,Cardiology and General Medicine, Barking, Havering and Redbridge University Hospitals NHS Trust, London, GBR.,Cardiology, Royal Free Hospital, London, GBR
| | | | - Tom Rayner
- Cardiology, Barts Heart Centre, London, GBR
| | - Sithu Kyaw
- Cardiology, Barts Heart Centre, London, GBR
| |
Collapse
|
9
|
Muacevic A, Adler JR. Effects and Complications of Subcutaneous Implantable Cardioverter-Defibrillator in the Prevention of Sudden Cardiac Death: A Narrative Review. Cureus 2022; 14:e30170. [PMID: 36397900 PMCID: PMC9648676 DOI: 10.7759/cureus.30170] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2022] [Accepted: 10/11/2022] [Indexed: 01/25/2023] Open
Abstract
An implantable cardioverter-defibrillator (ICD) is one of those devices that is a big boom for the prevention of sudden deaths due to heart failure. This particular device has been in use for just a couple of years, but its impact in the domain has brought about a considerable change in the way a specific issue of the cardiovascular system is tackled. Although subcutaneous or hypodermic implantable cardioverter-defibrillator (S-ICD) is considered to be a better alternative as far as transvenous implantable cardioverter-defibrillator (TV-ICD) is concerned, the former, being a newer introduction in the market, needs to be assessed in depth to clearly understand its effects and complications. Various types of research have been conducted on the efficacy of this device, and in most of the studies, the supremacy of this device is clearly evident when compared with other devices that are used for the same purpose. Better innovations in subcutaneous or hypodermic implantable cardioverter-defibrillators would enable them to be manufactured in a more efficient and cost-effective way so that a huge lot of people are benefited from this device. This review article is a whole peep into the various studies done in this domain, thereby providing adequate scientific insights about subcutaneous or hypodermic implantable cardioverter-defibrillators in a very simple and comprehensive manner.
Collapse
|
10
|
Müller J, Behnes M, Schupp T, Reiser L, Taton G, Reichelt T, Ellguth D, Borggrefe M, Engelke N, Bollow A, Kim SH, Weidner K, Ansari U, Mashayekhi K, Akin M, Halbfass P, Meininghaus DG, Akin I, Rusnak J. Clinical outcome of out-of-hospital vs. in-hospital cardiac arrest survivors presenting with ventricular tachyarrhythmias. Heart Vessels 2021; 37:828-839. [PMID: 34783873 PMCID: PMC8986738 DOI: 10.1007/s00380-021-01976-y] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/09/2021] [Accepted: 10/22/2021] [Indexed: 11/28/2022]
Abstract
Limited data regarding the prognostic impact of ventricular tachyarrhythmias related to out-of-hospital (OHCA) compared to in-hospital cardiac arrest (IHCA) is available. A large retrospective single-center observational registry with all patients admitted due to ventricular tachyarrhythmias was used including all consecutive patients with ventricular tachycardia (VT) and fibrillation (VF) on admission from 2002 to 2016. Survivors discharged after OHCA were compared to those after IHCA using multivariable Cox regression models and propensity-score matching for evaluation of the primary endpoint of long-term all-cause mortality at 2.5 years. Secondary endpoints were all-cause mortality at 6 months and cardiac rehospitalization at 2.5 years. From 2.422 consecutive patients with ventricular tachyarrhythmias, a total of 524 patients survived cardiac arrest and were discharged from hospital (OHCA 62%; IHCA 38%). In about 50% of all cases, acute myocardial infarction was the underlying disease leading to ventricular tachyarrhythmias with consecutive aborted cardiac arrest. Survivors of IHCA were associated with increased long-term all-cause mortality compared to OHCA even after multivariable adjustment (28% vs. 16%; log rank p = 0.001; HR 1.623; 95% CI 1.002-2.629; p = 0.049) and after propensity-score matching (28% vs. 19%; log rank p = 0.045). Rates of cardiac rehospitalization rates at 2.5 years were equally distributed between OHCA and IHCA survivors. In patients presenting with ventricular tachyarrhythmias, survivors of IHCA were associated with increased risk for all-cause mortality at 2.5 years compared to OHCA survivors.
Collapse
Affiliation(s)
- Julian Müller
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Michael Behnes
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Tobias Schupp
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Linda Reiser
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Gabriel Taton
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Thomas Reichelt
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Dominik Ellguth
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Martin Borggrefe
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Niko Engelke
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Armin Bollow
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Seung-Hyun Kim
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Kathrin Weidner
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Uzair Ansari
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Kambis Mashayekhi
- Department of Cardiology and Angiology II, University Heart Center Freiburg, Bad Krozingen, Germany
| | - Muharrem Akin
- Department of Cardiology and Angiology, Hannover Medical School, Hannover, Germany
| | - Philipp Halbfass
- Department of Interventional Electrophysiology, Heart Centre Bad, Neustadt, Germany
| | | | - Ibrahim Akin
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany
| | - Jonas Rusnak
- First Department of Medicine, Faculty of Medicine Mannheim, University Medical Centre Mannheim (UMM), European Centre for AngioSience (ECAS) and German Center for Cardiovascular Research (DZHK) Partner Site Heidelberg/Mannheim, Theodor-Kutzer-Ufer 1-3, 68167, Mannheim, Germany.
| |
Collapse
|
11
|
John LA, Karimianpour A, Gold MR. The Role of Subcutaneous ICDs in the Prevention of Sudden Cardiac Death. US CARDIOLOGY REVIEW 2021; 15:e19. [PMID: 39720500 PMCID: PMC11664769 DOI: 10.15420/usc.2021.01] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2021] [Accepted: 05/26/2021] [Indexed: 11/04/2022] Open
Abstract
The ICD is an important therapy in the prevention of sudden cardiac death. The transvenous-ICD (TV-ICD) has been the primary device used for this purpose. However, mechanical and infectious complications occur with traditional TV-ICDs increasing morbidity and mortality. The subcutaneous-ICD (S-ICD) system was developed to circumvent some of these complications, but S-ICDs have their inherent set of limitations as well. These include inappropriate shock delivery, lack of bradycardia, antitachycardia or CRT pacing therapy and shorter device longevity. The S-ICD is now included in guidelines as an acceptable alternative to TV-ICDs among patients without pacing indications. This review discusses the rationale for S-ICDs by reviewing studies including the PRAETORIAN, PAS, and UNTOUCHED trials.
Collapse
Affiliation(s)
- Leah A John
- Division of Cardiology, Medical University of South Carolina Charleston, SC
| | | | - Michael R Gold
- Division of Cardiology, Medical University of South Carolina Charleston, SC
| |
Collapse
|
12
|
Tonko JB, Rinaldi CA. Non-traditional implantable cardioverter-defibrillator configurations and insertion techniques: a review of contemporary options. Europace 2021; 24:181-192. [PMID: 34453529 PMCID: PMC8824518 DOI: 10.1093/europace/euab178] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2021] [Accepted: 07/01/2021] [Indexed: 11/14/2022] Open
Abstract
Implantable cardioverter-defibrillators (ICDs) have revolutionized the treatment of acquired or inherited cardiac diseases associated with a high risk of sudden cardiac death due to ventricular tachyarrhythmias. Contemporary ICD devices offer reliable arrhythmia detection and discrimination algorithms and deliver highly efficient tachytherapies. Percutaneously inserted transvenous defibrillator coils with pectoral generator placement are the first-line approach in the majority of adults due to their extensively documented clinical benefit and efficiency with comparably low periprocedural implantation risks as well as the option of providing pain-free tachycardia treatment via anti-tachycardia pacing (ATP), concomitant bradycardiaprotection, and incorporation in a cardiac resynchronization therapy if indicated. Yet, expanding ICD indications particularly among younger and more complex patient groups as well as the increasingly evident long-term consequences and complications associated with intravascular lead placements promoted the development of alternative ICD configurations. Most established in daily clinical practice is the subcutaneous ICD but other innovative extravascular approaches like epicardial, pericardial, extra-pleural, and most recently substernal defibrillator coil placements have been introduced as well to overcome shortcomings associated with traditional devices and allow for individualized treatment strategies tailored to the patients characteristics and needs. The review aims to provide practical solutions for common complications encountered with transvenous ICD systems including restricted venous access, high defibrillation/fibrillation thresholds (DFTs), and recurrent device infections. We summarize the contemporary options for non-traditional extravascular ICD configurations outlining indications, advantages, and disadvantages.
Collapse
Affiliation(s)
- Johanna B Tonko
- Department of Cardiology, St. Thomas' Hospital, Westminster Bridge Rd, London SE1 7EH, UK.,Department of Cardiovascular Imaging, Arrhythmia Research Group, King's College London, School of Biomedical Engineering & Imaging Sciences, London, UK
| | - Christopher A Rinaldi
- Department of Cardiology, St. Thomas' Hospital, Westminster Bridge Rd, London SE1 7EH, UK.,Department of Cardiovascular Imaging, Arrhythmia Research Group, King's College London, School of Biomedical Engineering & Imaging Sciences, London, UK
| |
Collapse
|
13
|
Narducci M, Scacciavillani R, Pinnacchio G, Bencardino G, Perna F, Comerci G, Campisi M, Ceccarelli I, Pavone C, Spera F, Bisignani A, Crea F, Pelargonio G. The potential impact of acute coronary syndromes on automatic sensing system in Subcutaneous-ICDs. IJC HEART & VASCULATURE 2021; 35:100841. [PMID: 34345651 PMCID: PMC8319739 DOI: 10.1016/j.ijcha.2021.100841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/13/2021] [Revised: 07/02/2021] [Accepted: 07/05/2021] [Indexed: 11/26/2022]
Abstract
BACKGROUND The Subcutaneous-ICD (S-ICD) is emerging as a suitable option for most ICD candidates, however some open issues regarding the sensing algorithm still remain. OBJECTIVES We aimed to examine the performance of the S-ICD sensing algorithm in patients hospitalized for ST elevation myocardial infarction (STEMI), non ST elevation acute coronary syndrome (NSTE-ACS) or chronic coronary syndrome (CCS), before and after revascularization. METHODS We performed a S-ICD automated screening on 75 patients, 21 hospitalized for STEMI, 23 for NSTE-ACS and 31 for CCS, before and after percutaneous revascularization, regardless their eligibility to ICD implantation. RESULTS Patients did not differ in clinical, electrocardiographic and echocardiographic parameters. Rates of screening pass were significantly lower in STEMI patients compared to NSTE-ACS and CCS (5% vs 56.7% vs 81% respectively, p < .0001). The viability of the primary vector was lower in STEMI patients compared to NSTE-ACS and CCS (33% vs 56% vs 71%, p .027 respectively). After revascularization, there were no more significant differences between groups. Pairing subjects at baseline and after revascularization, STEMI subjects percentages of screening success were respectively 5% and 81% (p < .001) and the rates of primary vector viability were 33% and 81% (p .002). STEMI was the only independent predictor of screening failure at multivariate logistic regression analysis (odds ratio 10.68 confidence interval 2.77-41.38, p = .001). CONCLUSION The performance of the S-ICD and possible malfunction detections in the context of an acute ischemic event deserve further evaluation. Adequate patient selection and the development of dynamic device programming are warranted.
Collapse
Affiliation(s)
- M.L. Narducci
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli, 8, Roma, Italy
| | - R. Scacciavillani
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli, 8, Roma, Italy
| | - G. Pinnacchio
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli, 8, Roma, Italy
| | - G. Bencardino
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli, 8, Roma, Italy
| | - F. Perna
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli, 8, Roma, Italy
| | - G. Comerci
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli, 8, Roma, Italy
| | - M. Campisi
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli, 8, Roma, Italy
| | - I. Ceccarelli
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli, 8, Roma, Italy
| | - C. Pavone
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli, 8, Roma, Italy
| | - F. Spera
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli, 8, Roma, Italy
| | - A. Bisignani
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli, 8, Roma, Italy
| | - F. Crea
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli, 8, Roma, Italy
- Cardiology Institute, Catholic University of Sacred Heart, Rome, Italy
| | - G. Pelargonio
- Department of Cardiovascular Sciences, Fondazione Policlinico Universitario Agostino Gemelli IRCCS, Largo Agostino Gemelli, 8, Roma, Italy
- Cardiology Institute, Catholic University of Sacred Heart, Rome, Italy
| |
Collapse
|
14
|
Karimianpour A, John L, Gold MR. The Subcutaneous ICD: A Review of the UNTOUCHED and PRAETORIAN Trials. Arrhythm Electrophysiol Rev 2021; 10:108-112. [PMID: 34401183 PMCID: PMC8353550 DOI: 10.15420/aer.2020.47] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Accepted: 02/17/2021] [Indexed: 11/05/2022] Open
Abstract
The ICD is an important part of the treatment and prevention of sudden cardiac death in many high-risk populations. Traditional transvenous ICDs (TV-ICDs) are associated with certain short- and long- term risks. The subcutaneous ICD (S-ICD) was developed in order to avoid these risks and complications. However, this system is associated with its own set of limitations and complications. First, patient selection is important, as S-ICDs do not provide pacing therapy currently. Second, pre-procedural screening is important to minimise T wave and myopotential oversensing. Finally, until recently, the S-ICD was primarily used in younger patients with fewer co-morbidities and less structural heart disease, limiting the general applicability of the device. S-ICDs achieve excellent rates of arrhythmia conversion and have demonstrated noninferiority to TV-ICDs in terms of complication rates in real-world studies. The objective of this review is to discuss the latest literature, including the UNTOUCHED and PRAETORIAN trials, and to address the risk of inappropriate shocks.
Collapse
Affiliation(s)
- Ahmadreza Karimianpour
- Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC, US
| | - Leah John
- Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC, US
| | - Michael R Gold
- Division of Cardiology, Department of Medicine, Medical University of South Carolina, Charleston, SC, US
| |
Collapse
|
15
|
Nakasuka K, Kitada S, Kawada Y, Kato M, Kikuchi S, Seo Y, Ohte N. Future bradyarrhythmia in patients with hypertrophic cardiomyopathy. IJC HEART & VASCULATURE 2021; 33:100735. [PMID: 33718587 PMCID: PMC7933266 DOI: 10.1016/j.ijcha.2021.100735] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Accepted: 02/03/2021] [Indexed: 10/26/2022]
Abstract
Background A few studies to evaluate an incidence of bradyarrhythmia in patients with hypertrophic cardiomyopathy (HCM) have been reported. Methods We enrolled 161 patients with HCM to evaluate their bradyarrhythmia risk, especially the risk of patients who were at risk for sudden cardiac death (SCD) and eligible for implantation of an implantable cardiac defibrillator (ICD). We defined symptomatic bradyarrhythmia requiring a pacing therapy as a bradyarrhythmia event and collected the data on an occurrence of the event after the time of diagnosis of HCM. The incidence of bradyarrhythmia events was compared between patients with ICD indications (ICD-candidate group) and those without (non-ICD-candidate group). Furthermore, we investigated the associated factors with bradyarrhythmia events using a Cox proportional-hazards model. Results During 5.5 ± 4.4 years follow-up, bradyarrhythmia events occurred in 8% (13 patients) of whole patients, and in 15% of the ICD-candidate group (n = 74). In contrast, only 2 events (2%) occurred in the non-ICD-candidate group. The incidence of bradyarrhythmia in the ICD-candidate group was significantly higher than that in the non-ICD-candidate group (log-rank p = 0.015). In the ICD-candidate group, a Cox proportional-hazards model demonstrated that lower heart rate at the time of diagnosis (HR: 1.072, 95%CI: 1.012 to 1.135, p = 0.018), and an eligibility of ICD implantation for secondary prevention of SCD (HR: 9.092, 95%CI: 2.644 to 31.258, p < 0.001) were significantly associated with future bradyarrhythmia. Conclusions HCM patients with eligibility for ICD implantation, especially for secondary prevention of SCD, more frequently suffered from bradyarrhythmia events.
Collapse
Affiliation(s)
- Kosuke Nakasuka
- Department of Cardiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Shuichi Kitada
- Department of Cardiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Yu Kawada
- Department of Cardiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Marina Kato
- Department of Cardiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Shohei Kikuchi
- Department of Cardiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Yoshihiro Seo
- Department of Cardiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| | - Nobuyuki Ohte
- Department of Cardiology, Nagoya City University Graduate School of Medical Sciences, Nagoya, Japan
| |
Collapse
|
16
|
|
17
|
Abstract
Cardiac implantable electronic devices (CIEDs) are essential for the management of a variety of cardiac conditions, including tachyarrhythmias, bradyarrhythmias, and medically refractory heart failure (HF). Recent advancements in CIED technology have led to innovative solutions that overcome shortcomings associated with traditional devices or address unmet needs. Leadless pacemakers, subcutaneous implantable cardioverter defibrillators (ICDs), and extravascular ICDs eliminate lead-related complications common with conventional pacemakers or ICDs. Conduction system pacing (His bundle pacing and left bundle branch pacing) is a more physiologic method of pacing and avoids the deleterious consequences associated with long-term right ventricular pacing. For HF-related devices, cardiac contractility modulation is an emerging therapy that bridges a gap for many patients ineligible for cardiac resynchronization therapy and has been shown to improve HF symptoms and decrease hospitalizations and mortality in select patients. Implantable pulmonary artery pressure monitors help guide HF management and reduce hospitalizations. Lastly, new phrenic nerve stimulating devices are being utilized to treat central sleep apnea, a common comorbidity associated with HF. While further long-term studies are still underway for many of these new technologies, it is anticipated that these devices will become indispensable therapeutics in the expanding cardiovascular armamentarium.
Collapse
|
18
|
Affiliation(s)
| | - Bogdan Enache
- Victor Babes University of Medicine and Pharmacy, Timisoara, Romania
| | - Rita F Redberg
- University of California, San Francisco, San Francisco, CA
| |
Collapse
|
19
|
Su L, Guo J, Hao Y, Tan H. Comparing the safety of subcutaneous versus transvenous ICDs: a meta-analysis. J Interv Card Electrophysiol 2021; 60:355-363. [PMID: 33432473 DOI: 10.1007/s10840-020-00929-1] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Accepted: 12/27/2020] [Indexed: 10/22/2022]
Abstract
PURPOSE The use of transvenous implantable cardioverter defibrillators (TV-ICDs) is associated with multiple risks related to the presence of the defibrillator leads within the venous system and right side of the heart, including endocarditis, venous occlusion, tricuspid regurgitation, and potential lead failure. The emergence of subcutaneous ICDs (S-ICDs) may potentially overcome the aforementioned disadvantages. However, evidence validating the safety of S-ICDs relative to TV-ICDs is limited. The present study aimed to synthesize and analyze available data from published studies to comprehensively compare transvenous and subcutaneous ICDs. METHODS Different databases were searched for full-text publications with a direct comparison of TV- and S-ICDs. Fixed effect models were applied to pooled data, and no study-to-study heterogeneity was detected. RESULTS Data from 7 studies totaling 1666 patients were pooled together. Compared to S-ICDs, the risk of suffering device-related complications was higher in patients with TV-ICDs (OR = 1.71; 95% CI: 1.23-2.38). The number of patients with an S-ICD who suffered inappropriate shocks (IS) was not significantly different than patients with a TV-ICD (OR = 0.92; 95% CI: 0.65-1.30). Subgroup analysis indicated that the TV-ICD group had a higher risk of IS due to supraventricular oversensing (OR = 3.29; 95% CI: 1.92-5.63) while T-wave oversensing tending to cause IS in the S-ICD group (OR = 0.09; 95% CI: 0.03-0.23). The risk of device-related infection in the S-ICD group was not any lower than that in the TV-ICD group (OR = 1.57; 95% CI: 0.67-3.68). The survival rate without any complications during a 1-year follow-up period was similar between the 2 groups (HR = 1.23; 95% CI: 0.81-1.86), although it was assumed that the trend leaned toward more complications in patients with a TV-ICD. CONCLUSION The present study verified the safety of S-ICDs based on pooled data. Although there were no differences between TV- and S-ICDs in the short term, fewer adverse events were found in patients with S-ICDs during long-term follow-up.
Collapse
Affiliation(s)
- Li Su
- The First Department of Gerontology, 960th Hospital of the People's Liberation Army, Jinan, 250001, China
| | - Jia Guo
- The First Department of Gerontology, 960th Hospital of the People's Liberation Army, Jinan, 250001, China
| | - Yingqun Hao
- The First Department of Gerontology, 960th Hospital of the People's Liberation Army, Jinan, 250001, China
| | - Hong Tan
- Department of Cardiology, 960th Hospital of the People's Liberation Army, No. 25 Shifan Road, Jinan, 250001, China.
| |
Collapse
|
20
|
Lai D, Fan X, Chen Q. A Numerical Evaluation of Multi-Lead Subcutaneous Implantable Cardioverter Defibrillator for Low Energy and Less Damage in Swine .. ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY. ANNUAL INTERNATIONAL CONFERENCE 2020; 2019:4889-4892. [PMID: 31946956 DOI: 10.1109/embc.2019.8856324] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
In the rescue of patients with sudden cardiac death, cardiac electric defibrillation is usually implemented, but the myocardial damage caused by exceeding defibrillation shock is irreversible. The aim of this study is to provide a numerically implanted optimization of a subcutaneous implantable cardioverter defibrillator (S-ICD) for low shock energy and less myocardial damage. In this paper, three anatomically realistic finite element models of swine were constructed for the evaluation study of six Can-Lead configurations with various number of leads at different placements. For each Can-Lead configuration, corresponding numerical modeling and simulation with the finite element method (FEM) were performed to pre-surgically assess quantitatively the efficiency of a certain defibrillation shock, besed on our previously reported multi-criteria evaluation of cardiac defibrillation. The results show that the outcome of an S-ICD shock depends on numbers of the implanted leads as well as the location of Can-Lead, and suggest that an S-ICD implantation with a left pectoral Can and two leads (located at the midline and at the left last ribs oblique upward) would possess the best efficiency of defibrillation, which could offer another option in clinical practice. In conclusion, on basis of the pre-surgical simulation of an S-ICD configuration, an individual optimization of cardiac defibrillation would be potentially useful for a lower energy and a less myocardial damage compared with current implantations with only the knowledge of clinical practices.
Collapse
|
21
|
Kaya E, Siebermair J, Vonderlin N, Hadjamu N, Azizy O, Rassaf T, Wakili R. Impact of diabetes as a risk factor in patients undergoing subcutaneous implantable cardioverter defibrillator implantation: A single-centre study. Diab Vasc Dis Res 2020; 17:1479164120911560. [PMID: 32292066 PMCID: PMC7510351 DOI: 10.1177/1479164120911560] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
INTRODUCTION Patients with diabetes mellitus are known to carry an increased risk for surgical site infections and perioperative complications. The subcutaneous implantable cardioverter defibrillator is an established treatment option in patients at risk for sudden cardiac death especially with an increased risk for infection over time. METHODS AND RESULTS Forty-eight patients (mean age = 55.0 ± 21.3 years, 31.3% patients with diabetes mellitus, 75% male) who underwent consecutive subcutaneous implantable cardioverter defibrillator surgery between February 2016 and May 2019 were retrospectively analysed. Overall adverse events including relevant bleeding complications, any surgical wound problems and infections requiring reoperation or device malfunction were evaluated as primary combined safety endpoint. Patients with diabetes mellitus tended to be older with a higher body mass index compared to non-diabetes mellitus. Procedure duration and postsurgery hospital days were not different in diabetes mellitus versus non-diabetes mellitus patients. Analysis of the primary combined endpoint showed no significant difference but a trend towards higher event rates in the diabetes mellitus group (diabetes mellitus vs non-diabetes mellitus: 20% vs 12.1%, p = 0.119). CONCLUSION Diabetes mellitus is a frequent and relevant variable in patients undergoing subcutaneous implantable cardioverter defibrillator implantation represented by 31.3% in this consecutive cohort. Our results suggest that diabetes mellitus is not associated with a prolonged hospital stay or increased rate of periprocedural adverse events.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Reza Wakili
- Reza Wakili, Department of Cardiology and Vascular Medicine, West German Heart and Vascular Center, University Hospital Essen, University of Duisburg–Essen, Essen, Hufelandstrasse 55, 45147 Essen, Germany.
| |
Collapse
|
22
|
Kaczmarek K, Kempa M, Grabowski M, Tajstra M, Sokal A, Cygankiewicz I, Zwoliński R, Michalak M, Kowara M, Budrejko S, Kurek A, Wranicz JK, Raczak G, Opolski G, Gąsior M, Kowalski O, Ptaszyński P. Multicentre early experience with totally subcutaneous cardioverter-defibrillators in Poland. Arch Med Sci 2020; 16:764-771. [PMID: 32542076 PMCID: PMC7286329 DOI: 10.5114/aoms.2019.83817] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/31/2018] [Accepted: 01/19/2019] [Indexed: 11/17/2022] Open
Abstract
INTRODUCTION Implantable cardioverter-defibrillators (ICD) have a strong position in the prevention of sudden death. Nowadays, the most commonly used high-energy cardiac devices are transvenous ICDs. A new technology of totally subcutaneous ICDs (S-ICD) was invented and recently introduced into clinical practice in order to reduce lead-related complications of conventional ICDs. The aim of this paper is to present early experience with this new technology implemented in a few centres in Poland. MATERIAL AND METHODS Medical records of patients who had S-ICD-related interventions in Poland were retrospectively analysed. RESULTS During the first year of S-ICD introduction into the Polish health system 18 patients underwent surgery connected with S-ICDs. Majority of them (17 patients) were implanted de novo. In one patient surgical revision of a device implanted abroad was performed. Most of patients (78%) had S-ICDs implanted for secondary prevention. Inability of transvenous system implantation due to venous access obstruction or high risk of infection related with transvenous leads accounted for 83% of indications for S-ICD. Only in three patients were S-ICDs implanted due to young age and active mode of life. The implantations of S-ICDs were performed without important early or late complications. During follow-up one patient had episodes of ventricular arrhythmia successfully terminated with high-energy shocks. One patient died due to progression of heart failure. CONCLUSIONS S-ICD implantation procedure has been successfully and safely introduced in Polish clinical routine. Nevertheless, despite clear indications in recent ESC guidelines, this therapy is not directly reimbursed in Poland and needs individual application for refund.
Collapse
Affiliation(s)
- Krzysztof Kaczmarek
- Department of Electrocardiology, Medical University of Lodz, Lodz, Poland
- Corresponding author: Krzysztof Kaczmarek MD, PhD, Department of Electrocardiology, Medical University of Lodz, 1/3 Sterlinga St, 91-425 Lodz, Poland, E-mail:
| | - Maciej Kempa
- Department of Cardiology and Electrotherapy, Medical University of Gdansk, Gdansk, Poland
| | - Marcin Grabowski
- 1 Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland
| | - Mateusz Tajstra
- 3 Chair and Department of Cardiology, Silesian Medical University, Katowice, Poland
| | - Adam Sokal
- Department of Cardiology, Congenital Heart Diseases and Electrotherapy, SIlesian Medical University, Katowice, Poland
| | - Iwona Cygankiewicz
- Department of Electrocardiology, Medical University of Lodz, Lodz, Poland
| | | | - Marcin Michalak
- 1 Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland
| | - Michal Kowara
- 1 Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland
| | - Szymon Budrejko
- Department of Cardiology and Electrotherapy, Medical University of Gdansk, Gdansk, Poland
| | - Anna Kurek
- 3 Chair and Department of Cardiology, Silesian Medical University, Katowice, Poland
| | - Jerzy K. Wranicz
- Department of Electrocardiology, Medical University of Lodz, Lodz, Poland
| | - Grzegorz Raczak
- Department of Cardiology and Electrotherapy, Medical University of Gdansk, Gdansk, Poland
| | - Grzegorz Opolski
- 1 Chair and Department of Cardiology, Medical University of Warsaw, Warsaw, Poland
| | - Mariusz Gąsior
- 3 Chair and Department of Cardiology, Silesian Medical University, Katowice, Poland
| | - Oskar Kowalski
- Department of Cardiology, Congenital Heart Diseases and Electrotherapy, SIlesian Medical University, Katowice, Poland
| | - Paweł Ptaszyński
- Department of Electrocardiology, Medical University of Lodz, Lodz, Poland
| |
Collapse
|
23
|
Letsas KP, Xydonas S, Karamichalakis N, Efremidis M, Manolatos D, Bazoukis G, Asvestas D, Vlachos K, Georgopoulos S, Saplaouras A, Winter J, Sideris A. Intermuscular implantation technique for subcutaneous cardioverter-defibrillators. Herz 2019; 44:541-545. [PMID: 29468258 DOI: 10.1007/s00059-018-4688-0] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Revised: 01/19/2018] [Accepted: 01/26/2018] [Indexed: 11/28/2022]
Abstract
BACKGROUND The conventional technique for subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation has been associated with pocket complications. The aim of this study was to evaluate the efficacy and safety of an alternative intermuscular technique for S‑ICD implantation. METHODS S-ICDs were implanted in ten consecutive patients (ten males, mean age: 46.8 ± 14.7 years). The pocket for the pulse generator was made above the serratus anterior muscular fascia and beneath the latissimus dorsi muscle by detaching the fibrous tissue between the muscles. Electrode implantation was performed using the three- (n = 4) or the two-incision technique (n = 6). RESULTS All S‑ICDs were successfully implanted in the absence of any procedure-related complications with a successful 65-J standard polarity defibrillation threshold testing, apart from one patient with Brugada syndrome who needed device repositioning more dorsally. During a mean follow-up of 16.5 ± 7.3 months, no major complications requiring surgical repair were encountered, while patients demonstrated high levels of comfort and satisfaction with the cosmetic result. One patient experienced an inappropriate shock due to noise detection, which was resolved after reprogramming to a different sensing vector. CONCLUSION The intermuscular technique is a safe and efficacious approach for S‑ICD implantation. This technique could lead to fewer pocket-related complications and better cosmetic results.
Collapse
Affiliation(s)
- K P Letsas
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Ipsilantou 47, 10676, Athens, Greece
| | - S Xydonas
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Ipsilantou 47, 10676, Athens, Greece
| | - N Karamichalakis
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Ipsilantou 47, 10676, Athens, Greece
| | - M Efremidis
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Ipsilantou 47, 10676, Athens, Greece
| | - D Manolatos
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Ipsilantou 47, 10676, Athens, Greece
| | - G Bazoukis
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Ipsilantou 47, 10676, Athens, Greece.
| | - D Asvestas
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Ipsilantou 47, 10676, Athens, Greece
| | - K Vlachos
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Ipsilantou 47, 10676, Athens, Greece
| | - S Georgopoulos
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Ipsilantou 47, 10676, Athens, Greece
| | - A Saplaouras
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Ipsilantou 47, 10676, Athens, Greece
| | - J Winter
- Division of Cardiac Surgery, University of Düsseldorf, 40225, Düsseldorf, Germany
| | - A Sideris
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Ipsilantou 47, 10676, Athens, Greece
| |
Collapse
|
24
|
Xiang K, Levine JD, Elayi SC, Su J, Hsu S, Kim R, Catanzaro JN. A novel bio envelope and suture orientation for stabilization of the subcutaneous implantable cardioverter-defibrillator generator to the chest wall. HeartRhythm Case Rep 2019; 5:430-432. [PMID: 31453096 PMCID: PMC6700997 DOI: 10.1016/j.hrcr.2019.05.003] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
|
25
|
Killu AM, Naksuk N, Stárek Z, DeSimone CV, Syed FF, Gaba P, Wolf J, Lehar F, Pesl M, Leinveber P, Crha M, Ladewig D, Powers J, Suddendorf S, Hodge DO, Satam G, Novák M, Kara T, Bruce CJ, Friedman PA, Asirvatham SJ. A Novel Defibrillation Tool: Percutaneously Delivered, Partially Insulated Epicardial Defibrillation. JACC Clin Electrophysiol 2019; 3:747-755. [PMID: 28736750 DOI: 10.1016/j.jacep.2016.12.025] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
Abstract
INTRODUCTION Epicardial defibrillation systems currently require surgical access. We aimed to develop a percutaneous defibrillation system with partially-insulated epicardial coils to focus electrical energy on the myocardium and prevent or minimize extra-cardiac stimulation. METHODS We tested 2 prototypes created for percutaneous introduction into the pericardial space via a steerable sheath. This included a partially-insulated defibrillation coil and a defibrillation mesh with a urethane balloon acting as an insulator to the face of the mesh not in contact with the epicardium. The average energy associated with a chance of successful defibrillation 75% of the time (ED75) was calculated for each experiment. RESULTS Of 16 animal experiments, 3 pig experiments had malfunctioning mesh prototypes such that results were unreliable; these were excluded. Therefore, 13 animal experiments were analyzed - 6 canines (29.8±4.0kg); 7 pigs (41.1±4.4kg). The overall ED75 was 12.8±6.7J (10.9±9.1J for canines; 14.4±3.9J in pigs [P=0.37]). The lowest ED75 obtained in canines was 2.5J while in pigs it was 9.5J. The lowest energy resulting in successful defibrillation was 2J in canines and 5J in pigs. There was no evidence of coronary vessel injury or trauma to extra-pericardial structures. CONCLUSION Percutaneous, epicardial defibrillation using a partially insulated coil is feasible and appears to be associated with low defibrillation thresholds. Focusing insulation may limit extra-cardiac stimulation and potentially lower energy requirements for efficient defibrillation.
Collapse
Affiliation(s)
- Ammar M Killu
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN
| | - Niyada Naksuk
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN
| | - Zdeněk Stárek
- Department of Cardiovascular Diseases, St Anne's University Hospital, Brno, Czech Republic
| | | | - Faisal F Syed
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN
| | | | - Jiří Wolf
- Department of Cardiovascular Diseases, St Anne's University Hospital, Brno, Czech Republic
| | - Frantisek Lehar
- Department of Cardiovascular Diseases, St Anne's University Hospital, Brno, Czech Republic
| | - Martin Pesl
- Department of Cardiovascular Diseases, St Anne's University Hospital, Brno, Czech Republic
| | - Pavel Leinveber
- Department of Cardiovascular Diseases, St Anne's University Hospital, Brno, Czech Republic
| | - Michal Crha
- University of Veterinary and Pharmaceutical Sciences Brno, Czech Republic
| | | | - Joanne Powers
- Department of Cardiovascular Surgery, Mayo Clinic, Rochester, MN
| | - Scott Suddendorf
- Department of Cardiovascular Surgery, Mayo Clinic, Rochester, MN
| | - David O Hodge
- Department of Health Science Research, Mayo Clinic, Jacksonville, FL
| | | | - Miroslav Novák
- Department of Cardiovascular Diseases, St Anne's University Hospital, Brno, Czech Republic
| | - Tomas Kara
- Department of Cardiovascular Diseases, St Anne's University Hospital, Brno, Czech Republic
| | - Charles J Bruce
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN
| | - Paul A Friedman
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN
| | - Samuel J Asirvatham
- Department of Cardiovascular Diseases, Mayo Clinic, Rochester, MN.,Department of Pediatrics and Adolescent Medicine, Mayo Clinic, Rochester, MN
| |
Collapse
|
26
|
van den Bruck JH, Sultan A, Plenge T, Seuthe K, Mödder T, Iliadis C, Stern D, Blankenheim T, Steven D, Lüker J. Incidence of myopotential induction in subcutaneous implantable cardioverter-defibrillator patients: Is the oversensing issue really solved? Heart Rhythm 2019; 16:1523-1530. [PMID: 31048064 DOI: 10.1016/j.hrthm.2019.04.044] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Indexed: 11/19/2022]
Abstract
BACKGROUND The subcutaneous implantable cardioverter-defibrillator (S-ICD) has established its role in the prevention of sudden cardiac death in a defined population. Inappropriate shocks and device malfunction in S-ICD therapy may be caused by myopotential (MP) oversensing. OBJECTIVE The purpose of this study was to systematically evaluate a cohort of consecutive S-ICD patients for MP inducibility. METHODS After S-ICD implantation, all vectors (primary [PrimV], secondary [SecV], alternative [AltV]) were analyzed during isometric chest press (ICP), lifting and holding a 20-kg weight, and side plank exercise (SPE), supporting the body weight on the left arm. When MPs were induced, signal classification was assessed: adequate noise detection, induced undersensing (R waves classified as noise), and oversensing (noise annotated as R waves). In case of noise induction in the current vector, device reprogramming to a noise-free vector was done. RESULTS We systematically assessed 41 patients. In nearly all patients (90.2%), MPs were inducible. ICP was the most potent inductor of MPs. Whereas SecV (70.7%) and AltV (75.6%) were most vulnerable during ICP, PrimV was most affected during SPE (51.2%). In only a few cases did the S-ICD software distinguish correctly between MPs and QRS. MPs predominantly led to undersensing (up to 65.9%), but in up to 22% of patients MP-induced oversensing occurred but did not lead to tachycardia detection. No relation was seen between S-ICD lead and generator position and MP inducibility. CONCLUSION Induction of MPs during physical exercise was observed frequently. Although in most cases MP noise led to undersensing, oversensing events were commonly observed.
Collapse
Affiliation(s)
- Jan-Hendrik van den Bruck
- University of Cologne, Department of Electrophysiology, University Hospital Cologne, Cologne, Germany.
| | - Arian Sultan
- University of Cologne, Department of Electrophysiology, University Hospital Cologne, Cologne, Germany
| | - Tobias Plenge
- University of Cologne, Department of Electrophysiology, University Hospital Cologne, Cologne, Germany
| | - Katharina Seuthe
- University of Cologne, Department of Electrophysiology, University Hospital Cologne, Cologne, Germany
| | - Tim Mödder
- University of Cologne, Department of Electrophysiology, University Hospital Cologne, Cologne, Germany
| | - Christos Iliadis
- University of Cologne, Department of Electrophysiology, University Hospital Cologne, Cologne, Germany
| | - Daniel Stern
- University of Cologne, Department of Electrophysiology, University Hospital Cologne, Cologne, Germany
| | - Tatjana Blankenheim
- University of Cologne, Department of Electrophysiology, University Hospital Cologne, Cologne, Germany
| | - Daniel Steven
- University of Cologne, Department of Electrophysiology, University Hospital Cologne, Cologne, Germany
| | - Jakob Lüker
- University of Cologne, Department of Electrophysiology, University Hospital Cologne, Cologne, Germany
| |
Collapse
|
27
|
Al-Ghamdi B. Subcutaneous Implantable Cardioverter Defibrillators: An Overview of Implantation Techniques and Clinical Outcomes. Curr Cardiol Rev 2019; 15:38-48. [PMID: 30014805 PMCID: PMC6367695 DOI: 10.2174/1573403x14666180716164740] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/12/2018] [Revised: 07/09/2018] [Accepted: 07/10/2018] [Indexed: 11/22/2022] Open
Abstract
Sudden Cardiac Death (SCD) is a significant health problem worldwide. Multiple randomized controlled trials have shown that Implantable Cardioverter Defibrillators (ICDs) are effective life-saving management option for individuals at risk of SCD in both primary and secondary prevention. Although the conventional transvenous ICDs (TV-ICDs) are safe and effective, there are potential complications associated with its use, including localized pocket or wound infection or systematic infection, a vascular access related complication such as pneumothorax, and venous thrombosis, and lead related complications such as dislodgement, malfunction, and perforation. Furthermore, transvenous leads placement may not be feasible in certain patients like those with venous anomaly or occlusion, or with the presence of intracardiac shunts. Transvenous leads extraction, when needed, is associated with considerable morbidity & mortality and requires significant skills and costs. Totally subcutaneous ICD (S-ICD) is designed to afford the same life-saving benefit of the conventional TV-ICDs while avoiding the shortcomings of the TV-leads and to simplify the implant techniques and hence expand the use of ICDs in clinical practice. It becomes commercially available after receiving CE mark in 2009, and its use increased significantly after its FDA approval in 2012. This review aims to give an overview of the S-ICD system components, implantation procedure, clinical indications, safety, efficacy, and future directions.
Collapse
Affiliation(s)
- Bandar Al-Ghamdi
- Heart Center, College of Medicine, King Faisal Specialist Hospital & Research Centre, Zahrawi St, Al Maather, Riyadh 12713, Saudi Arabia.,Alfaisal University, College of Medicine, King Faisal Specialist Hospital & Research Centre, Zahrawi St, Al Maather, Riyadh 12713, Saudi Arabia
| |
Collapse
|
28
|
Current Device Therapies for Sudden Cardiac Death Prevention – the ICD, Subcutaneous ICD and Wearable ICD. Heart Lung Circ 2019; 28:65-75. [DOI: 10.1016/j.hlc.2018.09.011] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2018] [Accepted: 09/23/2018] [Indexed: 02/06/2023]
|
29
|
Arias MA, Pachón M, Akerström F, Puchol A, Martín-Sierra C, Rodríguez-Padial L. Resultados agudos y a largo plazo tras implante contemporáneo de desfibrilador subcutáneo: experiencia en un centro. Rev Esp Cardiol 2018. [DOI: 10.1016/j.recesp.2017.08.020] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/16/2023]
|
30
|
Migliore F, Pelliccia F, Autore C, Bertaglia E, Cecchi F, Curcio A, Bontempi L, Curnis A, De Filippo P, D’Onofrio A, Francia P, Maurizi N, Musumeci B, Proclemer A, Zorzi A, Corrado D. Subcutaneous implantable cardioverter defibrillator in cardiomyopathies and channelopathies. J Cardiovasc Med (Hagerstown) 2018; 19:633-642. [DOI: 10.2459/jcm.0000000000000712] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
|
31
|
Sudden Death and Ventricular Arrhythmias in Athletes: Screening, De-Training and the Role of Catheter Ablation. Heart Lung Circ 2018; 28:155-163. [PMID: 30554599 DOI: 10.1016/j.hlc.2018.10.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2018] [Accepted: 10/05/2018] [Indexed: 01/29/2023]
Abstract
Athletes enjoy excellent health outcomes including greater longevity relative to non-athletic counterparts. Paradoxically, however, endurance athletic conditioning is associated with an increase in some arrhythmias. This review discusses the potential mechanisms for this paradox and strategies enabling early identification of potentially serious pathologies. Screening remains contentious due to the challenges of identifying relatively rare entities amongst a healthy cohort. The imperfect diagnostic accuracy of all current tests means that screening strategies have potential for harm through incorrect diagnoses as well as the potential for identification of important sub-clinical pathologies. Management of athletes at risk of ventricular arrhythmias and sudden cardiac death is similarly complex. There is much yet to learn about the specific patterns of ventricular arrhythmias in athletes, and the separation of benign from potentially life-threatening remains imperfect. There are some promising advances, however, such as specialised imaging modalities combined with improved electrophysiological diagnostics and therapeutics. Some unique clinical patterns are emerging to advance our understanding and management of athletes with ventricular arrhythmias, requiring specialised skillsets for evaluation and management.
Collapse
|
32
|
Kaya E, Jánosi RA, Azizy O, Wakili R, Rassaf T. Conscious sedation during subcutaneous implantable cardioverter-defibrillator implantation using the intermuscular technique. J Interv Card Electrophysiol 2018; 54:59-64. [DOI: 10.1007/s10840-018-0445-9] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/01/2018] [Accepted: 09/06/2018] [Indexed: 10/28/2022]
|
33
|
Diemberger I, Bonfiglioli R, Martignani C, Graziosi M, Biffi M, Lorenzetti S, Ziacchi M, Nanni C, Fanti S, Boriani G. Contribution of PET imaging to mortality risk stratification in candidates to lead extraction for pacemaker or defibrillator infection: a prospective single center study. Eur J Nucl Med Mol Imaging 2018; 46:194-205. [PMID: 30196365 DOI: 10.1007/s00259-018-4142-9] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2018] [Accepted: 08/19/2018] [Indexed: 11/28/2022]
Abstract
PURPOSE 18F-FDG PET/CT is an emerging technique for diagnosis of cardiac implantable electronic devices infection (CIEDI). Despite the improvements in transvenous lead extraction (TLE), long-term survival in patients with CIEDI is poor. The aim of the present study was to evaluate whether the extension of CIEDI at 18F-FDG PET/CT can improve prediction of survival after TLE. METHODS Prospective, monocentric observational study enrolling consecutive candidates to TLE for a diagnosis of CIEDI. 18F-FDG PET/CT was performed in all patients prior TLE. RESULTS There were 105 consecutive patients with confirmed CIEDI enrolled. An increased 18F-FDG uptake was limited to cardiac implantable electrical device (CIED) pocket in 56 patients, 40 patients had a systemic involvement. We had nine negative PET in patients undergoing prolonged antimicrobial therapy (22.5 ± 14.0 days vs. 8.6 ± 13.0 days; p = 0.005). Implementation of 18F-FDG PET/CT in modified Duke Criteria lead to reclassification of 23.8% of the patients. After a mean follow-up of 25.0 ± 9.0 months, 31 patients died (29.5%). Patients with CIED pocket involvement at 18F-FDG PET/CT presented a better survival independently of presence/absence of systemic involvement (HR 0.493, 95%CI 0.240-0.984; p = 0.048). After integration of 18F-FDG PET/CT data, absence of overt/hidden pocket involvement in CIEDI and a (glomerular filtration rate) GFR < 60 ml/min were the only independent predictors of mortality at long term. CONCLUSIONS Patient with CIEDI and a Cold Closed Pocket (i.e., a CIED pocket without skin erosion/perforation nor increased capitation at 18F-FDG PET/CT) present worse long-term survival. Patient management can benefit by systematic adoption of pre-TLE 18F-FDG PET/CT through improved identification of CIED related endocarditis (CIEDIE) and hidden involvement of CIED pocket.
Collapse
Affiliation(s)
- Igor Diemberger
- Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Via Massarenti n. 9, 40138, Bologna, Italy.
| | - Rachele Bonfiglioli
- Institute of Nuclear Medicine, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Bologna, Italy
| | - Cristian Martignani
- Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Via Massarenti n. 9, 40138, Bologna, Italy
| | - Maddalena Graziosi
- Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Via Massarenti n. 9, 40138, Bologna, Italy
| | - Mauro Biffi
- Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Via Massarenti n. 9, 40138, Bologna, Italy
| | - Stefano Lorenzetti
- Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Via Massarenti n. 9, 40138, Bologna, Italy
| | - Matteo Ziacchi
- Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Via Massarenti n. 9, 40138, Bologna, Italy
| | - Cristina Nanni
- Institute of Nuclear Medicine, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Bologna, Italy
| | - Stefano Fanti
- Institute of Nuclear Medicine, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Bologna, Italy
| | - Giuseppe Boriani
- Cardiology Division, Department of Diagnostics, Clinical and Public Health Medicine, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| |
Collapse
|
34
|
Diemberger I, Marazzi R, Casella M, Vassanelli F, Galimberti P, Luzi M, Borrelli A, Soldati E, Golzio PG, Fumagalli S, Francia P, Padeletti L, Botto G, Boriani G. The effects of gender on electrical therapies for the heart: procedural considerations, results and complications: A report from the XII Congress of the Italian Association on Arrhythmology and Cardiostimulation (AIAC). Europace 2018; 19:1911-1921. [PMID: 28520959 DOI: 10.1093/europace/eux034] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2016] [Accepted: 05/02/2017] [Indexed: 12/28/2022] Open
Abstract
Use of cardiac implantable devices and catheter ablation is steadily increasing in Western countries following the positive results of clinical trials. Despite the advances in scientific knowledge, tools development, and techniques improvement we still have some grey area in the field of electrical therapies for the heart. In particular, several reports highlighted differences both in medical behaviour and procedural outcomes between female and male candidates. Women are referred later for catheter ablation of supraventricular arrhythmias, especially atrial fibrillation, leading to suboptimal results. On the opposite females present greater response to cardiac resynchronization, while the benefit of implantable defibrillator in primary prevention seems to be less pronounced. Differences on aetiology, clinical profile, and development of myocardial scarring are the more plausible causes. This review will discuss all these aspects together with gender-related differences in terms of acute/late complications. We will also provide useful hints on plausible mechanisms and practical procedural aspects.
Collapse
Affiliation(s)
- Igor Diemberger
- Institute of Cardiology, Department of Experimental, Diagnostic and Specialty Medicine, University of Bologna, Policlinico S.Orsola-Malpighi, Via Massarenti n. 9, 40138, Bologna, Italy
| | - Raffaella Marazzi
- Department of Heart and Vessels, Ospedale di Circolo e Fondazione Macchi, University of Insubria, Varese, Italy
| | - Michela Casella
- Cardiac Arrhythmia Research Center, Centro Cardiologico Monzino IRCCS, Milan, Italy
| | - Francesca Vassanelli
- Chair and Unit of Cardiology, University of Brescia, Spedali Civili Hospital, Brescia, Italy
| | - Paola Galimberti
- Electrophysiology and Pacing Unit, Humanitas Clinical and Research Center, Rozzano-Milano, Italy
| | - Mario Luzi
- Cardiology Clinic, Marche Polytechnic University, Ancona, Italy
| | | | - Ezio Soldati
- Cardiac Thoracic and Vascular Department, University Hospital of Pisa, Italy
| | - Pier Giorgio Golzio
- Division of Cardiology, Department of Internal Medicine, Azienda Ospedaliero-Universitaria Città della Salute e della Scienza di Torino, Turin, Italy
| | - Stefano Fumagalli
- Intensive Care Unit, Geriatric Cardiology and Medicine Division, Experimental and Clinical Medicine Department, University of Florence and AOU Careggi, Florence, Italy
| | - Pietro Francia
- Cardiac Electrophysiology Unit, Cardiology, St. Andrea Hospital, University "Sapienza", Rome, Italy
| | - Luigi Padeletti
- University of Florence, Florence, Italy IRCCS MultiMedica, Sesto San Giovanni, Italy
| | - Gianluca Botto
- EP Unit, Department of Medicine, Sant'Anna Hospital, Como, Italy
| | - Giuseppe Boriani
- Cardiology Division, Department of Diagnostics, Clinical and Public Health Medicine, University of Modena and Reggio Emilia, Policlinico di Modena, Modena, Italy
| |
Collapse
|
35
|
Grabowski M, Gawałko M, Michalak M, Cacko A, Kowara M, Kołodzińska A, Januszkiewicz Ł, Balsam P, Vitali Serdoz L, Winter J, Opolski G. Initial experience with the subcutaneous implantable cardioverter-defibrillator with the real costs of hospitalization analysis in a single Polish center. Cardiol J 2018; 26:360-367. [PMID: 29611175 DOI: 10.5603/cj.a2018.0024] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/08/2017] [Revised: 02/11/2018] [Accepted: 02/12/2018] [Indexed: 11/25/2022] Open
Abstract
BACKGROUND The recent introduction of an entirely subcutaneous implantable cardioverter-defibril-lator (S-ICD) represents an important progress in the defibrillation technology towards a less invasive approach. This is a single-center observational study of S-ICD implantations in Poland. METHODS The S-ICD was implanted in 11 patients with standard indications for an ICD. Patients in whom the device was implanted were evaluated for adverse events and device function at hospital discharge. All hospitalization costs were calculated and summed up for all patients. Costs were divided into following categories: medical materials, pharmaceuticals, operating theatre staff, cardiology depart-ment staff, laboratory tests, non-laboratory tests and additional non-medical costs. RESULTS The mean age of patients was 51.6 ± 16.4 years, 9 were men and 2 were women. Four pa-tients had atrial fibrillation as the basal rhythm, 1 patient had atrial flutter and 6 patients had sinus rhythm. All patients had at least one condition that precluded the use of a traditional ICD system or the S-ICD was preferred due to other conditions, i.e. a history complicated transvenous ICD therapy (18%), anticipated higher risk of infection (27%), lack or difficult vascular access (18%), young age and anticipated high cumulated risk of lifetime device therapy (36%). The mean duration of the im-plantation procedure was 2 h. One patient developed a postoperative pocket hematoma. Mean total time of hospitalization was 28 (6-92) days. Average cost of hospitalization per patient was 21,014.29 EUR (minimal = 19,332.71 EUR and maximal = 24,824.14 EUR). CONCLUSIONS S-ICD implantation appears to provide a viable alternative to transvenous ICD, espe-cially for patients without pacing requirements.
Collapse
Affiliation(s)
- Marcin Grabowski
- 1st Department of Cardiology, Medical University of Warsaw, Poland.
| | - Monika Gawałko
- 1st Department of Cardiology, Medical University of Warsaw, Poland
| | - Marcin Michalak
- 1st Department of Cardiology, Medical University of Warsaw, Poland
| | - Andrzej Cacko
- 1st Department of Cardiology, Medical University of Warsaw, Poland
| | - Michał Kowara
- 1st Department of Cardiology, Medical University of Warsaw, Poland.,Chair and Department of Experimental and Clinical Pharmacology, Medical University of Warsaw, Poland
| | | | | | - Paweł Balsam
- 1st Department of Cardiology, Medical University of Warsaw, Poland
| | | | - Joachim Winter
- Division of Cardiac Surgery, University of Düsseldorf, Germany
| | - Grzegorz Opolski
- 1st Department of Cardiology, Medical University of Warsaw, Poland
| |
Collapse
|
36
|
Turnage TA, Kpaeyeh Jr JA, Gold MR. The Subcutaneous Implantable Cardioverter-Defibrillator: New Insights and Expanding Populations. US CARDIOLOGY REVIEW 2018. [DOI: 10.15420/usc.2017:37:1] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023] Open
Abstract
Implantable cardioverter defibrillators (ICDs) have become a mainstay of treatment in patients at risk for sudden cardiac death. The majority of contemporary ICDs are implanted transvenously; however, this approach carries acute procedural and long-term risks. The subcutaneous ICD (S-ICD) was developed, in part, to circumvent some of these adverse events or as an alternative option in patients unable to undergo transvenous implantation. Early promising trials evaluating the S-ICD were small and focused on niche populations. More recently, larger trials included broader populations with worse heart failure and co-morbidities that may be more representative of typical ICD recipients. These studies have consistently demonstrated positive results. This review describes the S-ICD system, implantation, and the safety and efficacy of the device.
Collapse
|
37
|
Konishi S, Minamiguchi H, Ozu K, Mizuno H, Hikoso S, Yamaguchi O, Sakata Y. Routine exercise testing could not predict T-wave oversensing in a patient after a subcutaneous implantable cardioverter-defibrillator implant. Clin Case Rep 2018; 6:309-313. [PMID: 29445468 PMCID: PMC5799622 DOI: 10.1002/ccr3.1345] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/04/2017] [Revised: 11/20/2017] [Accepted: 12/05/2017] [Indexed: 11/10/2022] Open
Abstract
Subcutaneous implantable cardioverter‐defibrillators (S‐ICDs) are susceptible to T‐wave oversensing (TWOS) caused by high rate‐dependent QRS–T morphology changes. We experienced an inappropriate S‐ICD shock due to TWOS, which could not be predicted by routine exercise testing. A newly available high‐pass filter might be effective for avoiding this.
Collapse
Affiliation(s)
- Shozo Konishi
- Department of Cardiovascular Medicine; Osaka Graduate School of Medicine; Suita Japan
| | - Hitoshi Minamiguchi
- Department of Cardiovascular Medicine; Osaka Graduate School of Medicine; Suita Japan
| | - Kentaro Ozu
- Department of Cardiovascular Medicine; Osaka Graduate School of Medicine; Suita Japan
| | - Hiroya Mizuno
- Department of Cardiovascular Medicine; Osaka Graduate School of Medicine; Suita Japan
| | - Shungo Hikoso
- Department of Cardiovascular Medicine; Osaka Graduate School of Medicine; Suita Japan
| | - Osamu Yamaguchi
- Department of Cardiovascular Medicine; Osaka Graduate School of Medicine; Suita Japan
| | - Yasushi Sakata
- Department of Cardiovascular Medicine; Osaka Graduate School of Medicine; Suita Japan
| |
Collapse
|
38
|
Arias MA, Pachón M, Akerström F, Puchol A, Martín-Sierra C, Rodríguez-Padial L. Acute and Long-term Results After Contemporary Subcutaneous Implantable Cardioverter-defibrillator Implantation: A Single-center Experience. ACTA ACUST UNITED AC 2017; 71:895-901. [PMID: 29221700 DOI: 10.1016/j.rec.2017.11.006] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2017] [Accepted: 09/11/2017] [Indexed: 01/13/2023]
Abstract
INTRODUCTION AND OBJECTIVES The subcutaneous implantable cardioverter-defibrillator (S-ICD) has emerged as an alternative to the transvenous defibrillator. The incidence of complications is similar, with inappropriate shocks (IS) being more frequent than those occurring with contemporary programming of transvenous defibrillators. Several improvements have been implemented after the S-ICD was approved for use in Europe in 2009. This study reports the results of S-ICD use in a single center, whose experience began late, at the end of 2013. METHODS Prospective observational study including consecutive patients with defibrillator indication and no indication for either permanent pacing or cardiac resynchronization who underwent S-ICD implantation. Implant data and long-term follow-up were analyzed. RESULTS An S-ICD was implanted in 50 patients who were deemed suitable after electrocardiographic screening. The mean age was 46.9±15 (range, 15-78) years and 72% were male. Thirty eight percent had left ventricular ejection fraction ≤ 35%. The most frequent heart disease was ischemic heart disease (34%), followed by hypertrophic cardiomyopathy (18%). The intermuscular technique was used, with 3 incisions in 10% and 2 incisions in the remaining 90%. Ventricular fibrillation was induced in 49 patients, with 100% effectiveness in their conversion. After a mean follow-up of 18.1 (range, 2.3-44.8) months, there were no late complications requiring surgical revision, the rate of IS was 0%, and 1 patient (2%) experienced appropriate shocks. CONCLUSIONS Improvements in technology, implant technique and device programming, along with appropriate patient selection, have led to outstanding acute and long-term results, especially regarding the absence of both IS and complications requiring surgical revision.
Collapse
Affiliation(s)
- Miguel A Arias
- Unidad de Arritmias y Electrofisiología Cardiaca, Servicio de Cardiología, Hospital Virgen de la Salud, Toledo, Spain.
| | - Marta Pachón
- Unidad de Arritmias y Electrofisiología Cardiaca, Servicio de Cardiología, Hospital Virgen de la Salud, Toledo, Spain
| | - Finn Akerström
- Unidad de Arritmias y Electrofisiología Cardiaca, Servicio de Cardiología, Hospital Virgen de la Salud, Toledo, Spain
| | - Alberto Puchol
- Unidad de Arritmias y Electrofisiología Cardiaca, Servicio de Cardiología, Hospital Virgen de la Salud, Toledo, Spain
| | - Cristina Martín-Sierra
- Unidad de Arritmias y Electrofisiología Cardiaca, Servicio de Cardiología, Hospital Virgen de la Salud, Toledo, Spain
| | - Luis Rodríguez-Padial
- Unidad de Arritmias y Electrofisiología Cardiaca, Servicio de Cardiología, Hospital Virgen de la Salud, Toledo, Spain
| |
Collapse
|
39
|
Letsas KP, Asvestas D, Baranchuk A, Liu T, Georgopoulos S, Efremidis M, Korantzopoulos P, Bazoukis G, Tse G, Sideris A, Takagi M, Ehrlich JR. Prognosis, risk stratification, and management of asymptomatic individuals with Brugada syndrome: A systematic review. Pacing Clin Electrophysiol 2017; 40:1332-1345. [PMID: 28994463 DOI: 10.1111/pace.13214] [Citation(s) in RCA: 31] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2017] [Revised: 08/30/2017] [Accepted: 09/10/2017] [Indexed: 12/17/2022]
Abstract
Brugada syndrome (BrS) is a primary electrical disease associated with increased risk of sudden cardiac death due to polymorphic ventricular arrhythmias. The prognosis, risk stratification, and management of asymptomatic individuals remain the most controversial issues in BrS. Furthermore, the decision to manage asymptomatic patients with an implantable cardioverter-defibrillator should be made after weighing the potential individual risk of future arrhythmic events against the risk of complications associated with the implant and follow-up of patients living with such devices, and the accompanying impairment of the quality of life. Several clinical, electrocardiographic, and electrophysiological markers have been proposed for risk stratification of subjects with BrS phenotype, but the majority have not yet been tested in a prospective manner in asymptomatic individuals. Recent data suggest that current risk factors are insufficient and cannot accurately predict sudden cardiac death events in this setting. This systematic review aims to discuss contemporary data regarding prognosis, risk stratification, and management of asymptomatic individuals with diagnosis of Brugada electrocardiogram pattern and to delineate the therapeutic approach in such cases.
Collapse
Affiliation(s)
- Konstantinos P Letsas
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Athens, Greece
| | - Dimitrios Asvestas
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Athens, Greece
| | - Adrian Baranchuk
- Division of Cardiology, Queen's University, Kingston General Hospital, Kingston, Ontario, Canada
| | - Tong Liu
- Department of Cardiology, Tianjin Institute of Cardiology, Second Hospital of Tianjin Medical University, Tianjin, P.R. China
| | - Stamatis Georgopoulos
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Athens, Greece
| | - Michael Efremidis
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Athens, Greece
| | | | - George Bazoukis
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Athens, Greece
| | - Gary Tse
- Department of Medicine and Therapeutics, Chinese University of Hong Kong, Hong Kong, SAR, P.R. China
- Li Ka Shing Institute of Health Sciences, Chinese University of Hong Kong, Hong Kong, SAR, P.R. China
| | - Antonios Sideris
- Second Department of Cardiology, Laboratory of Cardiac Electrophysiology, Evangelismos General Hospital of Athens, Athens, Greece
| | - Masahiko Takagi
- Department of Cardiovascular Medicine, Osaka City University Graduate School of Medicine, Osaka, Japan
| | | |
Collapse
|
40
|
Tachibana M, Nishii N, Morita H, Nakagawa K, Watanabe A, Nakamura K, Ito H. Exercise stress test reveals ineligibility for subcutaneous implantable cardioverter defibrillator in patients with Brugada syndrome. J Cardiovasc Electrophysiol 2017; 28:1454-1459. [DOI: 10.1111/jce.13315] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/04/2017] [Revised: 07/30/2017] [Accepted: 08/07/2017] [Indexed: 11/30/2022]
Affiliation(s)
- Motomi Tachibana
- Department of Cardiology; Sakakibara Heart Institute of Okayama; Okayama Japan
| | - Nobuhiro Nishii
- Department of Cardiovascular Therapeutics; Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences; Okayama Japan
| | - Hiroshi Morita
- Department of Cardiovascular Therapeutics; Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences; Okayama Japan
| | - Koji Nakagawa
- Department of Cardiovascular Medicine; Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences; Okayama Japan
| | - Atsuyuki Watanabe
- Department of Cardiovascular Medicine; Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences; Okayama Japan
| | - Kazufumi Nakamura
- Department of Cardiovascular Medicine; Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences; Okayama Japan
| | - Hiroshi Ito
- Department of Cardiovascular Medicine; Okayama University Graduate School of Medicine, Dentistry and Pharmaceutical Sciences; Okayama Japan
| |
Collapse
|
41
|
Nishii N, Tachibana M, Morimoto Y, Kawada S, Miyoshi A, Sugiyama H, Nakagawa K, Watanabe A, Nakamura K, Morita H, Ito H. Initial experience with the subcutaneous implantable cardioverter-defibrillator in a single Japanese center. J Arrhythm 2017; 33:338-341. [PMID: 28765769 PMCID: PMC5529595 DOI: 10.1016/j.joa.2017.02.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Revised: 01/23/2017] [Accepted: 02/19/2017] [Indexed: 11/24/2022] Open
Abstract
BACKGROUND The subcutaneous implantable cardioverter-defibrillator (S-ICD) is recognized as a viable alternative to the transvenous ICD. The safety and efficacy of this device has been demonstrated in Western countries, but studies with S-ICD implantation in Japanese patients have not been reported. METHODS AND RESULTS Twelve patients received an S-ICD implant in our institute between February and September 2016. All S-ICDs were successfully implanted without complications. One appropriate and one inappropriate therapy was identified. CONCLUSIONS S-ICD implantation appears to provide a viable alternative to transvenous ICD implantation for some Japanese patients. However, we should perform careful follow-up of patients to eliminate inappropriate therapy.
Collapse
Affiliation(s)
- Nobuhiro Nishii
- Department of Cardiovascular Therapeutics, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| | - Motomi Tachibana
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| | - Yoshimasa Morimoto
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| | - Satoshi Kawada
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| | - Akihito Miyoshi
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| | - Hiroyasu Sugiyama
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| | - Koji Nakagawa
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| | - Atsuyuki Watanabe
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| | - Kazufumi Nakamura
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| | - Hiroshi Morita
- Department of Cardiovascular Therapeutics, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| | - Hiroshi Ito
- Department of Cardiovascular Medicine, Okayama University Graduate School of Medicine, Dentistry, and Pharmaceutical Sciences, Okayama, Japan
| |
Collapse
|
42
|
Fuster V. Editor-in-Chief's Top Picks From 2016: Part Two. J Am Coll Cardiol 2017; 69:1010-1042. [PMID: 28231931 DOI: 10.1016/j.jacc.2017.01.005] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Each week, I record audio summaries for every article in JACC, as well as an issue summary. While this process has been incredibly time-consuming, I have become quite familiar with every paper that we publish. Thus, I personally select papers (both original investigations and review articles) from 15 distinct specialties each year for your review. In addition to my personal choices, I have included manuscripts that have been the most accessed or downloaded on our websites, as well as those selected by the JACC Editorial Board members. In order to present the full breadth of this important research in a consumable fashion, we will present these manuscripts in this issue of JACC. Part One included the sections: Basic & Translational Research, Cardiac Failure, Cardiomyopathies/Myocardial & Pericardial Diseases, Congenital Heart Disease, Coronary Disease & Interventions, and CVD Prevention & Health Promotion. Part Two includes the sections: CV Medicine & Society, Hypertension, Imaging, Metabolic & Lipid Disorders, Rhythm Disorders, Valvular Heart Disease, and Vascular Medicine (1-84).
Collapse
|
43
|
Liang J, Cha Y. Is hybrid subcutaneous implantable cardioverter-defibrillator and leadless pacemaker the future of device therapy? Int J Cardiol 2017; 235:201. [PMID: 28342500 DOI: 10.1016/j.ijcard.2017.02.132] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/13/2017] [Accepted: 02/24/2017] [Indexed: 10/19/2022]
Affiliation(s)
- Jinjun Liang
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan 430060, China; Cardiovascular Research Institute, Wuhan University, Wuhan 430060, China; Division of Cardiovascular Diseases, Mayo Clinic, Rochester, MN 55905, USA
| | - Yongmei Cha
- Division of Cardiovascular Diseases, Mayo Clinic, Rochester, MN 55905, USA.
| |
Collapse
|
44
|
Sideris S, Archontakis S, Gatzoulis KA, Anastasakis A, Sotiropoulos I, Arsenos P, Kasiakogias A, Terentes D, Trachanas K, Paschalidis E, Tousoulis D, Kallikazaros I. The subcutaneous ICD as an alternative to the conventional ICD system: Initial experience in Greece and a review of the literature. Hellenic J Cardiol 2017; 58:4-16. [PMID: 28163146 DOI: 10.1016/j.hjc.2017.01.010] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2015] [Accepted: 08/31/2016] [Indexed: 01/11/2023] Open
Abstract
The introduction of an implantable cardioverter defibrillator (ICD) in clinical practice has revolutionized our therapeutic approach for both primary and secondary prevention of sudden cardiac death (SCD), as it has proven to be superior to medical therapy in treating potentially life-threatening ventricular arrhythmias and has resulted in reduced mortality rates. However, implantation of a conventional ICD carries a non-negligible risk of periprocedural and long-term complications associated with the transvenous ICD leads. The entirely subcutaneous implantable cardioverter defibrillator (S-ICD) has recently emerged as a therapeutic alternative to the conventional ICD for patients with various cardiopathies and who are at high risk of SCD. The main advantage is the avoidance of vascular access and thus avoidance of complications associated with transvenous leads. Patients without pacing indications, such as bradycardia, a need for antitachycardia pacing or cardiac resynchronization, as well as those at higher risk of complications from transvenous lead implantation are perfect candidates for this novel technology. The subcutaneous ICD has proven to be equally safe and effective compared to transvenous ICD systems in early clinical trials. Further technical improvements of the system will likely lead to the expansion of indications and widespread use of this technology. In the present review, we discuss the indications for this system, summarize early clinical experiences and highlight the advantages and disadvantages of this novel technology. In addition, we present the first two cases of subcutaneous cardioverter defibrillator system implantation in Greece.
Collapse
Affiliation(s)
- Skevos Sideris
- State Department of Cardiology, Hippokration Hospital, 114 Vasilisis Sofias street, 11528, Athens, Greece.
| | - Stefanos Archontakis
- First Cardiology Division, University of Athens, Medical School, Hippokration Hospital, 114 Vasilisis Sofias street, 11528, Athens, Greece
| | - Konstantinos A Gatzoulis
- First Cardiology Division, University of Athens, Medical School, Hippokration Hospital, 114 Vasilisis Sofias street, 11528, Athens, Greece
| | - Aristotelis Anastasakis
- First Cardiology Division, University of Athens, Medical School, Hippokration Hospital, 114 Vasilisis Sofias street, 11528, Athens, Greece
| | - Ilias Sotiropoulos
- State Department of Cardiology, Hippokration Hospital, 114 Vasilisis Sofias street, 11528, Athens, Greece
| | - Petros Arsenos
- First Cardiology Division, University of Athens, Medical School, Hippokration Hospital, 114 Vasilisis Sofias street, 11528, Athens, Greece
| | - Alexandros Kasiakogias
- State Department of Cardiology, Hippokration Hospital, 114 Vasilisis Sofias street, 11528, Athens, Greece
| | - Dimitrios Terentes
- State Department of Cardiology, Hippokration Hospital, 114 Vasilisis Sofias street, 11528, Athens, Greece
| | - Konstantinos Trachanas
- State Department of Cardiology, Hippokration Hospital, 114 Vasilisis Sofias street, 11528, Athens, Greece
| | - Eleftherios Paschalidis
- State Department of Cardiology, Hippokration Hospital, 114 Vasilisis Sofias street, 11528, Athens, Greece
| | - Dimitrios Tousoulis
- First Cardiology Division, University of Athens, Medical School, Hippokration Hospital, 114 Vasilisis Sofias street, 11528, Athens, Greece
| | - Ioannis Kallikazaros
- State Department of Cardiology, Hippokration Hospital, 114 Vasilisis Sofias street, 11528, Athens, Greece
| |
Collapse
|
45
|
Sex-Specific Data for the Subcutaneous Implantable Cardioverter-Defibrillator. J Am Coll Cardiol 2016; 68:133. [PMID: 27364060 DOI: 10.1016/j.jacc.2016.02.085] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/12/2016] [Accepted: 02/16/2016] [Indexed: 11/23/2022]
|
46
|
Trivedi A, Knight BP. ICD Therapy for Primary Prevention in Hypertrophic Cardiomyopathy. Arrhythm Electrophysiol Rev 2016; 5:188-196. [PMID: 28116084 DOI: 10.15420/aer.2016:30:2] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 12/30/2022] Open
Abstract
Hypertrophic cardiomyopathy (HCM) is a common and heterogeneous disorder that increases an individual's risk of sudden cardiac death (SCD). This review article discusses the relevant factors that are involved in the challenge of preventing SCD in patients with HCM. The epidemiology of SCD in patients is reviewed as well as the structural and genetic basis behind ventricular arrhythmias in HCM. The primary prevention of SCD with implantable cardioverter-defibrillator (ICD) therapy is the cornerstone of modern treatment for individuals at high risk of SCD. The focus here is on the current and emerging predictors of SCD as well as risk stratification recommendations from both North American and European guidelines. Issues related to ICD implantation, such as programming, complications and inappropriate therapies, are discussed. The emerging role of the fully subcutaneous ICD and the data regarding its implantation are reviewed.
Collapse
Affiliation(s)
- Amar Trivedi
- Division of Cardiology, Department of Medicine, Northwestern University, Chicago, IL, USA
| | - Bradley P Knight
- Division of Cardiology, Department of Medicine, Northwestern University, Chicago, IL, USA
| |
Collapse
|