1
|
Hidaka T, Miyamoto S, Furuse K, Fukunaga Y, Oshima A, Matsuura K, Higashino T. Evaluation of aesthetic outcomes of mandibular reconstruction using artificial intelligence. Head Neck 2024; 46:2699-2708. [PMID: 38698733 DOI: 10.1002/hed.27797] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Revised: 04/16/2024] [Accepted: 04/23/2024] [Indexed: 05/05/2024] Open
Abstract
BACKGROUND Although vascularized bone graft (VBG) transfer is the current standard for mandibular reconstruction, reconstruction with a mandibular reconstruction plate (MRP) and with a soft-tissue flap (STF) alone remain crucial options for patients with poor general conditions. However, objective aesthetic outcome evaluations for these methods are limited. METHODS In a retrospective analysis of 65 patients (VBG, 33; MRP, 19; and STF, 13), mandibular asymmetry value was calculated for each patient's photograph using facial recognition AI, with a higher value indicating worse asymmetry. RESULTS The MRP group had a value comparable to the VBG group regardless of mandibular defect types. The STF group had a significantly higher value than the VBG group. CONCLUSIONS Regarding cosmesis, STF was inferior to VBG, whereas MRP was comparable to VBG, even for anterior defects for which rigid reconstruction is mandatory. However, MRP's risks of plate-related complications limit its use to cases where VBG is contraindicated or with poor prognosis. LEVEL OF EVIDENCE: 4
Collapse
Affiliation(s)
- Takeaki Hidaka
- Department of Plastic and Reconstructive Surgery, National Cancer Center Hospital East, Kashiwa, Japan
| | - Shimpei Miyamoto
- Department of Plastic, Reconstructive and Aesthetic Surgery, Graduate School of Medicine, The University of Tokyo, Hongo, Japan
| | - Kiichi Furuse
- Department of Plastic and Reconstructive Surgery, National Cancer Center Hospital East, Kashiwa, Japan
| | - Yutaka Fukunaga
- Department of Plastic Surgery, Naruto Hospital, Naruto, Japan
| | - Azusa Oshima
- Department of Plastic and Reconstructive Surgery, National Cancer Center Hospital East, Kashiwa, Japan
| | - Kazuto Matsuura
- Department of Head and Neck Surgery, National Cancer Center Hospital East, Kashiwa, Japan
| | - Takuya Higashino
- Department of Plastic and Reconstructive Surgery, National Cancer Center Hospital East, Kashiwa, Japan
| |
Collapse
|
2
|
Tapan M, İsler VC, Akman RF, Özkan Ö, Özkan Ö. An Oroauricular Fistula After Mandibular Osteosarcoma Resection. HANDCHIR MIKROCHIR P 2023; 55:462-465. [PMID: 37678410 DOI: 10.1055/a-2125-0407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/09/2023] Open
Abstract
Bone tumors are rare malignancies and osteosarcoma is the most common malignant bone tumor. However, only 6% of all osteosarcomas occur in the mandible and maxilla 1. The location of these tumors also presents a unique set of challenges during resection and repair when compared to long bone tumors.
Collapse
|
3
|
Kämmerer PW, Al-Nawas B. Bone reconstruction of extensive maxillomandibular defects in adults. Periodontol 2000 2023; 93:340-357. [PMID: 37650475 DOI: 10.1111/prd.12499] [Citation(s) in RCA: 13] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 05/21/2023] [Accepted: 05/26/2023] [Indexed: 09/01/2023]
Abstract
Reconstruction of significant maxillomandibular defects is a challenge that has been much discussed over the last few decades. Fundamental principles were developed decades ago (bone bed viability, graft immobilization). Clinical decision-making criteria are highly relevant, including local/systemic factors and incision designs, the choice of material, grafting technique, and donor site morbidity. Stabilizing particulated grafts for defined defects-that is, via meshes or shells-might allow significant horizontal and vertical augmentation; the alternatives are onlay and inlay techniques. More significant defects might require extra orally harvested autologous bone blocks. The anterior iliac crest is often used for nonvascularized augmentation, whereas more extensive defects often require microvascular reconstruction. In those cases, the free fibula flap has become the standard of care. The development of alternatives is still ongoing (i.e., alloplastic reconstruction, zygomatic implants, obturators, distraction osteogenesis). Especially for these complex procedures, three-dimensional planning tools enable facilitated planning and a surgical workflow.
Collapse
Affiliation(s)
- Peer W Kämmerer
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Mainz, Germany
| | - Bilal Al-Nawas
- Department of Oral and Maxillofacial Surgery, University Medical Center Mainz, Mainz, Germany
| |
Collapse
|
4
|
Bräuer C, Ullmann K, Lauer G, Franke A, McLeod NMH, Leonhardt H. Alloplastic reconstruction of the mandible after subtotal mandibulectomy for medication-related osteonecrosis of the jaw: An update of the method. Head Neck 2023; 45:2638-2648. [PMID: 37622613 DOI: 10.1002/hed.27489] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 07/04/2023] [Accepted: 07/27/2023] [Indexed: 08/26/2023] Open
Abstract
BACKGROUND Reconstruction of continuity defects following osteonecrosis in multimorbid patients is challenging. In all cases of the predescribed palliative treatment method for alloplastic mandible reconstruction, plate fractures were detected in follow-up. We hypothesized that a modification could avoid these fractures, leading to stable long-term results. METHODS This retrospective study compares the original method with a modification using single, laser-sintered CAD-CAM plates instead of manually bent miniplates. The predescribed shuttering technique was used to reconstruct the mandible in its original shape with bone cement. RESULTS Uneventful wound healing was observed in 86% of the cases after modification of the method. No implant or plate fracture occurred. CONCLUSIONS The presented method should be considered as a treatment option for mandible reconstruction in elderly, multimorbid patients in palliative situations. The results of this study suggest that the modification of the method leads to significantly improved long-term stability. Donor site morbidity is avoided with this method of palliative surgery.
Collapse
Affiliation(s)
- Christian Bräuer
- Department of Oral & Maxillofacial Surgery, Dresden University Hospital, Dresden, Germany
- Department of Oral & Maxillofacial Surgery, Facial Plastic Surgery, Universitätsmedizin Rostock, Rostock, Germany
| | - Katrin Ullmann
- Department of Prosthodontics, Dresden University Hospital, Dresden, Germany
| | - Günter Lauer
- Department of Oral & Maxillofacial Surgery, Dresden University Hospital, Dresden, Germany
| | - Adrian Franke
- Department of Oral & Maxillofacial Surgery, Dresden University Hospital, Dresden, Germany
| | - Niall M H McLeod
- Department of Oral & Maxillofacial Surgery, University Hospitals of Leicester, NHS TRUST, Leicester, UK
| | - Henry Leonhardt
- Department of Oral & Maxillofacial Surgery, Dresden University Hospital, Dresden, Germany
| |
Collapse
|
5
|
Molteni G, Gazzini L, Sacchetto A, Nocini R, Comini LV, Arietti V, Locatello LG, Mannelli G. Mandibular reconstruction in head and neck cancer: which is the gold standard? Eur Arch Otorhinolaryngol 2023; 280:3953-3965. [PMID: 37269408 DOI: 10.1007/s00405-023-08050-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2023] [Accepted: 05/30/2023] [Indexed: 06/05/2023]
Abstract
INTRODUCTION The aim of this study is to perform a systematic review to compare the outcomes of the different surgical options for mandibular reconstruction in head and neck cancer. MATERIAL AND METHODS 93 articles were selected. Four groups were identified: titanium plate without flaps, titanium plate covered by soft tissue flap, bone tissue flaps and double flaps. We compared patients' characteristics, site of mandibulectomy, type of reconstruction and complications. RESULTS 4697 patients were reported. The groups were not homogeneous regarding the type of defect and the treatment history. A significant difference in terms of post-operative complications was found between group 1 and group 2 (p < 0.00001), and between group 2 and group 3 (p < 0.00001). Total complications rate for group 4 was significantly higher when compared to group 3 (p < 0.00001), but no significant difference was found with group 2. CONCLUSION These results suggest that mandibular reconstruction using a microvascular bone flap is the best surgical option in patients without significant comorbidities.
Collapse
Affiliation(s)
- Gabriele Molteni
- Young Confederation of European ORL-HNS, Y-CEORL-HNS, Vienna, Austria
- Head and Neck Department, University Hospital of Verona, Verona, Italy
- Department of Surgery, Dentistry and Pediatrics, University of Verona, Verona, Italy
| | - Luca Gazzini
- Young Confederation of European ORL-HNS, Y-CEORL-HNS, Vienna, Austria
- Otorhinolaryngology-Head and Neck Surgery Department, San Maurizio Hospital, Bolzano, Italy
| | - Andrea Sacchetto
- Young Confederation of European ORL-HNS, Y-CEORL-HNS, Vienna, Austria.
- Department of Otolaryngology, Ospedale San Bortolo, AULSS 8 Berica, Vicenza, Italy.
| | - Riccardo Nocini
- Young Confederation of European ORL-HNS, Y-CEORL-HNS, Vienna, Austria
- Department of Surgery, Dentistry and Pediatrics, University of Verona, Verona, Italy
| | - Lara Valentina Comini
- Young Confederation of European ORL-HNS, Y-CEORL-HNS, Vienna, Austria
- Otorhinolaryngology Unit, Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| | - Valerio Arietti
- Young Confederation of European ORL-HNS, Y-CEORL-HNS, Vienna, Austria
- Department of Surgery, Dentistry and Pediatrics, University of Verona, Verona, Italy
| | - Luca Giovanni Locatello
- Young Confederation of European ORL-HNS, Y-CEORL-HNS, Vienna, Austria
- Department of Otorhinolaryngology, Sant'Antonio Abate Hospital, Azienda Sanitaria Universitaria Friuli Centrale, Tolmezzo, Italy
| | - Giuditta Mannelli
- Young Confederation of European ORL-HNS, Y-CEORL-HNS, Vienna, Austria
- Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy
| |
Collapse
|
6
|
Gielisch MW, Siegberg F, Thiem DGE, Blatt S, Heimes D, Kämmerer PW. A novel alloplastic grid reconstruction plate for the mandible - Retrospective comparative clinical analysis of failure rates and specific complications. J Craniomaxillofac Surg 2023; 51:448-453. [PMID: 37550114 DOI: 10.1016/j.jcms.2023.07.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2023] [Revised: 05/25/2023] [Accepted: 07/30/2023] [Indexed: 08/09/2023] Open
Abstract
PURPOSE This study aimed to investigate the effect of three different osteosynthesis plate systems on failure rates and complications after continuity-interrupting mandibular resections with alloplastic reconstructions. MATERIALS AND METHODS Records of respective patients from 2010 to 2020 were analyzed retrospectively. The analyses included the osteosynthesis plate type (2.4 MANDIBULAR (RP1: MANDIBULAR [Medicon®, Tuttlingen, Germany]; RP2: Modus® Reco 2.5 [Medartis®, Basel, Switzerland]; and RP3: Modus 2 Mandible [Medartis®, Basel, Switzerland]), extent & location of the defect, age, sex, radiotherapy, and nicotine abuse. In case of failure, timepoint, and the problem, namely oral/extraoral dehiscence, screw loosening, and plate fractures that led to removal, were analyzed. Complications were classified according to Clavien-Dindo system. RESULTS A total of 136 patients were included. The mean follow-up time was 18 ± 26 months. Survival rates after 1, 2, and 5 years were 69.9%, 66.9%, and 64.7%, respectively. Although survival was not significantly associated with the reconstruction system, the most frequent complications were seen in cases of RP1 & RP2 when compared to RP3 (p = 0.033). In brief, dehiscences were seen significantly less often in cases of RP3 (12.5%) when compared to RP1 (44.7%) and RP2 (26.9%; p = 0.024). Fractures of the osteosynthesis systems occurred in 3 of 4 cases (75%) with RP1, in 1 of 4 cases (25%) using RP2, and in no single case using the RP3 system (p = 0.03). Most of the observed complications occurred up to 12 months postoperatively. A total plate survival rate of 64.7% and a total plate complication rate of 47.8% were seen. CONCLUSION In conclusion, it seems that RP3 should be preferred over RP1 and RP2 regarding failure rates and complications.
Collapse
Affiliation(s)
- Matthias W Gielisch
- Department of Oral and Maxillofacial Surgery - Plastic Operations, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Fabia Siegberg
- Department of Oral and Maxillofacial Surgery - Plastic Operations, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Daniel G E Thiem
- Department of Oral and Maxillofacial Surgery - Plastic Operations, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Sebastian Blatt
- Department of Oral and Maxillofacial Surgery - Plastic Operations, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Diana Heimes
- Department of Oral and Maxillofacial Surgery - Plastic Operations, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany
| | - Peer W Kämmerer
- Department of Oral and Maxillofacial Surgery - Plastic Operations, University Medical Center Mainz, Augustusplatz 2, 55131, Mainz, Germany.
| |
Collapse
|
7
|
Schottey O, Huys SE, van Lenthe G, Mommaerts MY, Sloten JV. Development of a topologically optimized patient-specific mandibular reconstruction implant for a Brown class II defect. ANNALS OF 3D PRINTED MEDICINE 2023. [DOI: 10.1016/j.stlm.2023.100107] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/22/2023] Open
|
8
|
Paré A, Charbonnier B, Veziers J, Vignes C, Dutilleul M, De Pinieux G, Laure B, Bossard A, Saucet-Zerbib A, Touzot-Jourde G, Weiss P, Corre P, Gauthier O, Marchat D. Standardized and axially vascularized calcium phosphate-based implants for segmental mandibular defects: A promising proof of concept. Acta Biomater 2022; 154:626-640. [PMID: 36210043 DOI: 10.1016/j.actbio.2022.09.071] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 09/09/2022] [Accepted: 09/28/2022] [Indexed: 12/14/2022]
Abstract
The reconstruction of massive segmental mandibular bone defects (SMDs) remains challenging even today; the current gold standard in human clinics being vascularized bone transplantation (VBT). As alternative to this onerous approach, bone tissue engineering strategies have been widely investigated. However, they displayed limited clinical success, particularly in failing to address the essential problem of quick vascularization of the implant. Although routinely used in clinics, the insertion of intrinsic vascularization in bioengineered constructs for the rapid formation of a feeding angiosome remains uncommon. In a clinically relevant model (sheep), a custom calcium phosphate-based bioceramic soaked with autologous bone marrow and perfused by an arteriovenous loop was tested to regenerate a massive SMD and was compared to VBT (clinical standard). Animals did not support well the VBT treatment, and the study was aborted 2 weeks after surgery due to ethical and animal welfare considerations. SMD regeneration was successful with the custom vascularized bone construct. Implants were well osseointegrated and vascularized after only 3 months of implantation and totally entrapped in lamellar bone after 12 months; a healthy yellow bone marrow filled the remaining space. STATEMENT OF SIGNIFICANCE: Regenerative medicine struggles with the generation of large functional bone volume. Among them segmental mandibular defects are particularly challenging to restore. The standard of care, based on bone free flaps, still displays ethical and technical drawbacks (e.g., donor site morbidity). Modern engineering technologies (e.g., 3D printing, digital chain) were combined to relevant surgical techniques to provide a pre-clinical proof of concept, investigating for the benefits of such a strategy in bone-related regenerative field. Results proved that a synthetic-biologics-free approach is able to regenerate a critical size segmental mandibular defect of 15 cm3 in a relevant preclinical model, mimicking real life scenarii of segmental mandibular defect, with a full physiological regeneration of the defect after 12 months.
Collapse
Affiliation(s)
- Arnaud Paré
- INSERM, U 1229, Laboratory of Regenerative Medicine and Skeleton, RMeS, Nantes Université, 1 Place Alexis Ricordeau, Nantes 44042, France; Department of Maxillofacial and Plastic surgery, Burn Unit, University Hospital of Tours, Trousseau Hospital, Avenue de la République, Chambray lès Tours 37170, France
| | - Baptiste Charbonnier
- INSERM, U 1229, Laboratory of Regenerative Medicine and Skeleton, RMeS, Nantes Université, 1 Place Alexis Ricordeau, Nantes 44042, France; Mines Saint-Étienne, Univ Jean Monnet, INSERM, U 1059 Sainbiose, 42023, Saint-Étienne, France
| | - Joëlle Veziers
- INSERM, U 1229, Laboratory of Regenerative Medicine and Skeleton, RMeS, Nantes Université, 1 Place Alexis Ricordeau, Nantes 44042, France
| | - Caroline Vignes
- INSERM, U 1229, Laboratory of Regenerative Medicine and Skeleton, RMeS, Nantes Université, 1 Place Alexis Ricordeau, Nantes 44042, France
| | - Maeva Dutilleul
- INSERM, U 1229, Laboratory of Regenerative Medicine and Skeleton, RMeS, Nantes Université, 1 Place Alexis Ricordeau, Nantes 44042, France
| | - Gonzague De Pinieux
- Department of Pathology, University Hospital of Tours, Trousseau Hospital, Avenue de la République, Chambray lès Tours 37170, France
| | - Boris Laure
- Department of Maxillofacial and Plastic surgery, Burn Unit, University Hospital of Tours, Trousseau Hospital, Avenue de la République, Chambray lès Tours 37170, France
| | - Adeline Bossard
- ONIRIS Nantes-Atlantic College of Veterinary Medicine, Research Center of Preclinical Invesitagtion (CRIP), Site de la Chantrerie, 101 route de Gachet, Nantes 44307, France
| | - Annaëlle Saucet-Zerbib
- ONIRIS Nantes-Atlantic College of Veterinary Medicine, Research Center of Preclinical Invesitagtion (CRIP), Site de la Chantrerie, 101 route de Gachet, Nantes 44307, France
| | - Gwenola Touzot-Jourde
- INSERM, U 1229, Laboratory of Regenerative Medicine and Skeleton, RMeS, Nantes Université, 1 Place Alexis Ricordeau, Nantes 44042, France; ONIRIS Nantes-Atlantic College of Veterinary Medicine, Research Center of Preclinical Invesitagtion (CRIP), Site de la Chantrerie, 101 route de Gachet, Nantes 44307, France
| | - Pierre Weiss
- INSERM, U 1229, Laboratory of Regenerative Medicine and Skeleton, RMeS, Nantes Université, 1 Place Alexis Ricordeau, Nantes 44042, France
| | - Pierre Corre
- INSERM, U 1229, Laboratory of Regenerative Medicine and Skeleton, RMeS, Nantes Université, 1 Place Alexis Ricordeau, Nantes 44042, France; Clinique de Stomatologie et Chirurgie Maxillo-Faciale, Nantes University Hospital, 1 Place Alexis Ricordeau, Nantes 44042, France
| | - Olivier Gauthier
- INSERM, U 1229, Laboratory of Regenerative Medicine and Skeleton, RMeS, Nantes Université, 1 Place Alexis Ricordeau, Nantes 44042, France; ONIRIS Nantes-Atlantic College of Veterinary Medicine, Research Center of Preclinical Invesitagtion (CRIP), Site de la Chantrerie, 101 route de Gachet, Nantes 44307, France
| | - David Marchat
- Mines Saint-Étienne, Univ Jean Monnet, INSERM, U 1059 Sainbiose, 42023, Saint-Étienne, France.
| |
Collapse
|
9
|
Lee UL, Yun S, Lee H, Cao HL, Woo SH, Jeong YH, Jung TG, Kim CM, Choung PH. Osseointegration of 3D-printed titanium implants with surface and structure modifications. Dent Mater 2022; 38:1648-1660. [PMID: 36075761 DOI: 10.1016/j.dental.2022.08.003] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2022] [Revised: 08/13/2022] [Accepted: 08/18/2022] [Indexed: 11/03/2022]
Abstract
BACKGROUND The purpose of this study was to establish a mechanical and histological basis for the development of biocompatible maxillofacial reconstruction implants by combining 3D-printed porous titanium structures and surface treatment. Improved osseointegration of 3D-printed titanium implants for reconstruction of maxillofacial segmental bone defect could be advantageous in not only quick osseointegration into the bone tissue but also in stabilizing the reconstruction. METHODS Various macro-mesh titanium scaffolds were fabricated by 3D-printing. Human mesenchymal stem cells were used for cell attachment and proliferation assays. Osteogenic differentiation was confirmed by quantitative polymerase chain reaction analysis. The osseointegration rate was measured using micro computed tomography imaging and histological analysis. RESULTS In three dimensional-printed scaffold, globular microparticle shape was observed regardless of structure or surface modification. Cell attachment and proliferation rates increased according to the internal mesh structure and surface modification. However, osteogenic differentiation in vitro and osseointegration in vivo revealed that non-mesh structure/non-surface modified scaffolds showed the most appropriate treatment effect. CONCLUSION 3D-printed solid structure is the most suitable option for maxillofacial reconstruction. Various mesh structures reduced osteogenesis of the mesenchymal stem cells and osseointegration compared with that by the solid structure. Surface modification by microarc oxidation induced cell proliferation and increased the expression of some osteogenic genes partially; however, most of the markers revealed that the non-anodized solid scaffold was the most suitable for maxillofacial reconstruction.
Collapse
Affiliation(s)
- Ui-Lyong Lee
- Department of Oral & Maxillofacial Surgery, Chung-Ang University Hospital, Seoul 06973, South Korea; Department of Oral & Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, Seoul 03080, South Korea.
| | - Seokhwan Yun
- Research Institute, Sphebio Co., Ltd., Pohang-si, Gyeongsanbuk 37666, South Korea
| | - Ho Lee
- Department of Oral and Maxillofacial Surgery, Section of Dentistry, Seoul Metropolitan Government - Seoul National University Boramae Medical Center, Seoul, South Korea
| | - Hua-Lian Cao
- Department of Oral & Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, Seoul 03080, South Korea
| | - Su-Heon Woo
- R&D Center, Medyssey Co, Ltd, Jechon, Chungcheongbuk-do 27159, South Korea
| | - Yong-Hoon Jeong
- Biomaterial Team, Dept. of Research & Development, Medical Device Development Center/Osong Medical Innovation Foundation, Cheongju, Chungcheongbuk-do 28160, South Korea
| | - Tae-Gon Jung
- Biomaterial Team, Dept. of Research & Development, Medical Device Development Center/Osong Medical Innovation Foundation, Cheongju, Chungcheongbuk-do 28160, South Korea
| | - Chul Min Kim
- Department of Mechatronics, Gyeongsang National University, Jinju-si, Gyeongsangnam-do 52828, South Korea
| | - Pill-Hoon Choung
- Department of Oral & Maxillofacial Surgery, Dental Research Institute, School of Dentistry, Seoul National University, Seoul 03080, South Korea
| |
Collapse
|
10
|
van Kootwijk A, Moosabeiki V, Saldivar MC, Pahlavani H, Leeflang MA, Kazemivand Niar S, Pellikaan P, Jonker BP, Ahmadi SM, Wolvius EB, Tümer N, Mirzaali MJ, Zhou J, Zadpoor AA. Semi-automated digital workflow to design and evaluate patient-specific mandibular reconstruction implants. J Mech Behav Biomed Mater 2022; 132:105291. [PMID: 35660552 DOI: 10.1016/j.jmbbm.2022.105291] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2022] [Revised: 05/18/2022] [Accepted: 05/19/2022] [Indexed: 12/31/2022]
Abstract
The reconstruction of large mandibular defects with optimal aesthetic and functional outcomes remains a major challenge for maxillofacial surgeons. The aim of this study was to design patient-specific mandibular reconstruction implants through a semi-automated digital workflow and to assess the effects of topology optimization on the biomechanical performance of the designed implants. By using the proposed workflow, a fully porous implant (LA-implant) and a topology-optimized implant (TO-implant) both made of Ti-6Al-4V ELI were designed and additively manufactured using selective laser melting. The mechanical performance of the implants was predicted by performing finite element analysis (FEA) and was experimentally assessed by conducting quasi-static and cyclic biomechanical tests. Digital image correlation (DIC) was used to validate the FE model by comparing the principal strains predicted by the FEM model with the measured distribution of the same type of strain. The numerical predictions were in good agreement with the DIC measurements and the predicted locations of specimen failure matched the actual ones. No statistically significant differences (p < 0.05) in the mean stiffness, mean ultimate load, or mean ultimate displacement were detected between the LA- and TO-implant groups. No implant failures were observed during quasi-static or cyclic testing under masticatory loads that were substantially higher (>1000 N) than the average maximum biting force of healthy individuals. Given its relatively lower weight (16.5%), higher porosity (17.4%), and much shorter design time (633.3%), the LA-implant is preferred for clinical application. This study clearly demonstrates the capability of the proposed workflow to develop patient-specific implants with high precision and superior mechanical performance, which will greatly facilitate cost- and time-effective pre-surgical planning and is expected to improve the surgical outcome.
Collapse
Affiliation(s)
- A van Kootwijk
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - V Moosabeiki
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands.
| | - M Cruz Saldivar
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - H Pahlavani
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - M A Leeflang
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - S Kazemivand Niar
- Department of Mechanical Engineering, Tarbiat Modares University, Tehran, Iran
| | - P Pellikaan
- Amber Implants BV, Prinses Margrietplantsoen 33, 2595 AM, The Hague, the Netherlands
| | - B P Jonker
- Department of Oral and Maxillofacial Surgery, Erasmus University Medical Center, Doctor Molewaterplein 40, 3015 GE, Rotterdam, the Netherlands
| | - S M Ahmadi
- Amber Implants BV, Prinses Margrietplantsoen 33, 2595 AM, The Hague, the Netherlands
| | - E B Wolvius
- Department of Oral and Maxillofacial Surgery, Erasmus University Medical Center, Doctor Molewaterplein 40, 3015 GE, Rotterdam, the Netherlands
| | - N Tümer
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - M J Mirzaali
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - J Zhou
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| | - A A Zadpoor
- Department of Biomechanical Engineering, Faculty of Mechanical, Maritime and Materials Engineering, Delft University of Technology (TU Delft), Mekelweg 2, 2628 CD, Delft, the Netherlands
| |
Collapse
|
11
|
Chen CF, Chen CM, Chen HS, Huang WC, Chen YC, Chang HC, Liu SH, Yang TL, Wang LL, Chen PH. The Use of Customized Three-Dimensionally Printed Mandible Prostheses with a Pressure-Reducing Device: A Finite Element Analysis in Different Chewing Positions, Biomechanical Testing, and In Vivo Animal Study Using Lanyu Pigs. BIOMED RESEARCH INTERNATIONAL 2022; 2022:9880454. [PMID: 35342763 PMCID: PMC8942632 DOI: 10.1155/2022/9880454] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/28/2021] [Revised: 02/06/2022] [Accepted: 02/11/2022] [Indexed: 01/05/2023]
Abstract
Segmental bony defects of the mandible constitute a complete loss of the regional part of the mandible. Although several types of customized three-dimension-printed mandible prostheses (CMPs) have been developed, this technique has yet to be widely used. We used CMP with a pressure-reducing device (PRD) to investigate its clinical applicability. First, we used the finite element analysis (FEA). We designed four models of CMP (P1 to P4), and the result showed that CMP with posterior PRD deployment (P4 group) had the maximum total deformation in the protrusion and right excursion positions, and in clenching and left excursion positions, posterior screws had the minimum von Mises stress. Second, the P4 CMP-PRD was produced using LaserCUSING from titanium alloy (Ti-6Al-4V). The fracture test result revealed that the maximum static pressure that could be withstood was 189 N, and a fatigue test was conducted for 5,000,000 cycles. Third, animal study was conducted on five male 4-month-old Lanyu pigs. Four animals completed the experiment. Two animals had CMP exposure in the oral cavity, but there was no significant inflammation, and one animal had a rear wing fracture. According to a CT scan, the lingual cortex of the mandible crawled along the CMP surface, and a bony front-to-back connection was noted in one animal. A histological examination indicated that CMP was significantly less reactive than control materials (p = 0.0170). Adequate PRD deployment in CMP may solve a challenge associated with CMP, thus promoting its use in clinical practice.
Collapse
Affiliation(s)
- Chun-Feng Chen
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
- Department of Oral and Maxillofacial Surgery, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan
- Dental Laboratory Technology, Shu Zen College of Medicine and Management, Kaohsiung, Taiwan
| | - Chun-Ming Chen
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| | - Han-Sheng Chen
- Dental Department, Kaohsiung Municipal Siaogang Hospital, Kaohsiung, Taiwan
| | - Wei-Chin Huang
- Laser and Additive Manufacturing Technology Center, Industrial Technology Research Institute, Taiwan
| | - Yung-Chung Chen
- School of Dentistry and Institute of Oral Medicine, College of Medicine, National Cheng Kung University, Tainan, Taiwan
| | - Hung-Chih Chang
- Department of biomedical engineering, Hungkuang University, Taichung, Taiwan
| | - Sung-Ho Liu
- Laser and Additive Manufacturing Technology Center, Industrial Technology Research Institute, Taiwan
| | - Tsung-Lung Yang
- KSVGH Originals & Enterprises, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan
| | - Ling-Lin Wang
- KSVGH Originals & Enterprises, Kaohsiung Veterans General Hospital, Kaohsiung, Taiwan
| | - Ping-Ho Chen
- School of Dentistry, College of Dental Medicine, Kaohsiung Medical University, Kaohsiung, Taiwan
| |
Collapse
|
12
|
Risk factors for reconstruction plate exposure after surgery in oral cancer patients. A retrospective cohort study. Clin Oral Investig 2022; 26:4127-4136. [DOI: 10.1007/s00784-022-04382-4] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Accepted: 01/11/2022] [Indexed: 11/03/2022]
|
13
|
Demir E, Yalçın G, Kalaycı A, Sağlam H. Biomechanical evaluation of caudally and buccally screwed customised reconstruction plates for lateral segmental defects of mandible. Br J Oral Maxillofac Surg 2021; 59:928-934. [PMID: 34454776 DOI: 10.1016/j.bjoms.2020.10.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2020] [Accepted: 10/23/2020] [Indexed: 10/23/2022]
Abstract
The aim of this study was to compare locking reconstruction plates with caudobuccally screwed custom mandibular reconstruction plates in bridging lateral mandibular segmental defects. The in vitro study was conducted on 13 polyurethane mandibles. A total of 7 mandibles with lateral segmental defects were bridged with locking reconstruction plates in group I, 6 mandibles with the same standard defect were bridged with caudobuccally screwed customised reconstruction plates in group II. Mean yield displacement, yield load, and displacement at 80 N (Newtons), 100 N, 200 N, 300 N loading were compared among the 2 groups. The mean (SD) displacement for Group I was 11.27 (3.6) mm, Group II was 21.08 (2.5) mm. Group II had significantly greater (p=0.0001) displacement when compared with Group I. The mean (SD) force before failure for Group I was 638.4 N (127.2), Group II was 1398. 3 N (162.7). Group II withstood significantly greater force than Group I (p=0.0001). The study reveals that the caudobuccally screwed custom reconstruction plates can significantly enhance yield load as preserving the preoperative shape of the face and mandible.
Collapse
Affiliation(s)
- E Demir
- Department of Oral and Maxillofacial Surgery, Selçuk University Faculty of Dentistry, Konya, Turkey.
| | - G Yalçın
- Department of Mechanics of Materials, Selçuk University Faculty of Technology, Konya, Turkey
| | - A Kalaycı
- Department of Oral and Maxillofacial Surgery, Selçuk University Faculty of Dentistry, Konya, Turkey
| | - H Sağlam
- Department of Mechanics of Materials, Selçuk University Faculty of Technology, Konya, Turkey
| |
Collapse
|
14
|
Wu K, Li S, Wu H, Zhang S. Evaluating the use of anterolateral thigh flaps to prevent reconstruction plate exposure in patients with oral cancer. Oral Surg Oral Med Oral Pathol Oral Radiol 2021; 133:277-281. [PMID: 34511352 DOI: 10.1016/j.oooo.2021.06.018] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 06/08/2021] [Accepted: 06/28/2021] [Indexed: 10/20/2022]
Abstract
OBJECTIVE Plate exposure remains one of the most serious complications of oromandibular reconstruction. The purpose of this study was to investigate the effect of wrapping reconstruction plates with anterolateral thigh (ALT) free flaps as a way to prevent plate exposure. STUDY DESIGN A total of 91 patients with composite oromandibular defects who underwent surgical reconstruction using a reconstruction plate in conjunction with an ALT musculocutaneous flap were recruited. The participants were divided into 2 groups, based on whether the plate was wrapped with or covered by the ALT flap. RESULTS The incidence of plate exposure in the experimental group (17%) was significantly lower than that of the control group (43.1%; P < .0001). The mean time from reconstruction until plate exposure in the experimental group was 19.4 ± 23.6 months, whereas the mean time in the control group was 12.3 ± 9.1 months. In the logistic regression model for the occurrence of plate exposure, the only factor found to be associated with plate exposure was how the ALT flap was used (P = .026). CONCLUSIONS The results of the present study indicate that wrapping the reconstruction plate with an ALT flap decreased the incidence of plate exposure in patients with oromandibular defects.
Collapse
Affiliation(s)
- Kun Wu
- Department of Oral and Maxillofacial Surgery, Second Xiangya Hospital of Central South University, Changsha, Hunan, China
| | - Sainan Li
- Department of Oral and Maxillofacial Surgery, Second Xiangya Hospital of Central South University, Changsha, Hunan, China
| | - Hanjiang Wu
- Department of Oral and Maxillofacial Surgery, Second Xiangya Hospital of Central South University, Changsha, Hunan, China
| | - Sheng Zhang
- Department of Oral and Maxillofacial Surgery, Second Xiangya Hospital of Central South University, Changsha, Hunan, China.
| |
Collapse
|
15
|
Song IS, Ryu JJ, Choi YJ, Lee UL. Pre-contoured reconstruction plate fabricated via three-dimensional printed bending support. J Korean Assoc Oral Maxillofac Surg 2021; 47:233-236. [PMID: 34187965 PMCID: PMC8249193 DOI: 10.5125/jkaoms.2021.47.3.233] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 02/22/2021] [Accepted: 02/23/2021] [Indexed: 11/12/2022] Open
Abstract
A mandibular continuity defect can be repaired using either a prosthetic device or autogenous bone. A titanium reconstruction plate can be used with a localized or vascularized flap over the defect of the mandible. Unfortunately, the plate may fail due to plate exposure, screw loosening, fracture, or infection, and will need to be removed. Plate exposure though the skin or mucosa is one of the main reasons for failure. In the present work, the authors introduced a lingually positioned reconstruction plate fabricated via three-dimensional printed bending support. This custom reconstruction plate can avoid plate re-exposure as well as reduce surgical errors and operation time.
Collapse
Affiliation(s)
- In-Seok Song
- Department of Dentistry, Korea University Anam Hospital, Seoul, Korea
| | - Jae-Jun Ryu
- Department of Dentistry, Korea University Anam Hospital, Seoul, Korea
| | - Young-Jun Choi
- Department of Oral and Maxillofacial Surgery, Chung-Ang University School of Medicine, Seoul, Korea.,Department of Oral and Maxillofacial Surgery, Dental Center, Chung-Ang University Hospital, Seoul, Korea
| | - Ui-Lyong Lee
- Department of Oral and Maxillofacial Surgery, Dental Center, Chung-Ang University Hospital, Seoul, Korea
| |
Collapse
|
16
|
Uchiyama Y, Sasai T, Nakatani A, Shimamoto H, Tsujimoto T, Kreiborg S, Murakami S. Distant metastasis from oral cavity-correlation between histopathology results and primary site. Oral Radiol 2021; 37:167-179. [PMID: 32468449 DOI: 10.1007/s11282-020-00440-3] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2019] [Accepted: 04/19/2020] [Indexed: 12/16/2022]
Abstract
OBJECTIVES Oral cancer is the eighth most common type of cancer worldwide and a significant contributor to the global burden caused by this disease. The principal parameters considered to influence prognosis, and thus treatment selection, are size and location of the primary tumor, as well as assessment of the presence and extent of lymph node and distant metastasis (DM). However, no known report regarding the relationship between the primary site and DM has been presented. For effective treatment selection and good prognosis, the correlation of DM with anatomic site and histopathology results of the primary malignancy is important. In the present study, we performed a systematic review of published reports in an effort to determine the relationship between the anatomic site of various types of oral cavity cancer and DM. METHODS A systematic review of articles published until the end of 2018 was performed using PubMed/MEDLINE. RESULTS A total of 150 studies were selected for this review. The percentage of all cases reported with DM was 6.3%, ranging from 0.6% to 33.1% in the individual studies. The rate of incidence of tongue occurrence was 9.3%. A frequent DM site was the lungs, with adenoid cystic carcinoma the most commonly involved histopathological factor. Malignant melanoma was most frequent (43.4%) in all histopathology findings, whereas there were no cases with an acinic cell carcinoma or cystadenocarcinoma. CONCLUSIONS We found that the occurrence of DM from the primary site as well as rate of incidence was dependent on histopathological factors.
Collapse
Affiliation(s)
- Yuka Uchiyama
- Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan.
| | - Tadashi Sasai
- Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Atsutoshi Nakatani
- Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Hiroaki Shimamoto
- Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Tomomi Tsujimoto
- Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
| | - Sven Kreiborg
- Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
- 3D Craniofacial Image Research Laboratory, University of Copenhagen, Copenhagen, Denmark
| | - Shumei Murakami
- Department of Oral and Maxillofacial Radiology, Osaka University Graduate School of Dentistry, 1-8 Yamadaoka, Suita, Osaka, 565-0871, Japan
- 3D Craniofacial Image Research Laboratory, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
17
|
KARGARNEJAD SAHAND, GHALICHI FARZAN, POURGOL-MOHAMMAD MOHAMMAD, OSKUI IZ, GARAJEI ATA. BIOMECHANICAL EVALUATION OF RECONSTRUCTED EXTENSIVE MANDIBULAR DEFECTS BY DIFFERENT MODELS USING FINITE ELEMENT METHOD. J MECH MED BIOL 2020. [DOI: 10.1142/s0219519420500530] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Rehabilitation of major mandibular defects after tumor resection has become a serious challenge for surgeons. In this research, four various models were designed to repair a critical mandibular lateral defect. Biomechanical behavior of the models was assessed by Finite Element Method. These models are including Fibular-Free Flap (FFF), Customized Prosthesis (CP), Tray Implant without Bone Graft (TI-wo-BG), and Tray Implant with Bone Graft (TI-w-BG). FFF is a subset of microvascular free flap technique in which some segments of patient’s fibula bone are used to restore mandibular defects. CP is a hollow and light prosthesis which is fabricated using Additive Manufacturing technology from Ti alloy powder. TI-wo-BG is similar to a crib which is designed according to the geometry of the patient’s mandible. TI-w-BG, in fact, is a TI-wo-BG which is filled with small cortico-cancellous chips in order to benefit potential profit of bone grafting. The chewing operation and loading on the mandible was simulated considering the three mandibular muscular forces including masseter, medial pterygoid, and temporalis. The result of FEM analysis of TI-wo-BG and TI-w-BG showed that in both models, screw number 6 endured a strain of 5684 and 2852[Formula: see text][Formula: see text]m/m which exceeded pathological and mild overload risk, respectively. This may increase the probability of screw loosening and system failure. The results proved the stability of the FFF and CP models. In addition, it can be concluded that stress and strain on the screw’s interfaces can decrease by improving the plate and increasing the friction at the interface of plate, bone and screw.
Collapse
Affiliation(s)
- SAHAND KARGARNEJAD
- Faculty of Biomedical Engineering, Sahand University of Technology, P.O. Box: 51335/1996, Sahand New Town, Tabriz, Iran
| | - FARZAN GHALICHI
- Faculty of Biomedical Engineering, Sahand University of Technology, P.O. Box: 51335/1996, Sahand New Town, Tabriz, Iran
| | - MOHAMMAD POURGOL-MOHAMMAD
- Mechanical Engineering Department, Sahand University of Technology, P.O. Box: 51335/1996, Sahand New Town, Tabriz, Iran
| | - I. Z. OSKUI
- Faculty of Biomedical Engineering, Sahand University of Technology, P.O. Box: 51335/1996, Sahand New Town, Tabriz, Iran
| | - ATA GARAJEI
- Department of Oral and Maxillofacial Surgery, School of Dentistry, Tehran, Iran
- The Cancer Institute, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran
- The Cancer Institute, Imam Hospital Complex, Keshavarz Blvd., Tehran, Iran
| |
Collapse
|
18
|
Lee UL, Lim JY, Park SN, Choi BH, Kang H, Choi WC. A Clinical Trial to Evaluate the Efficacy and Safety of 3D Printed Bioceramic Implants for the Reconstruction of Zygomatic Bone Defects. MATERIALS 2020; 13:ma13204515. [PMID: 33053855 PMCID: PMC7601564 DOI: 10.3390/ma13204515] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/16/2020] [Revised: 10/06/2020] [Accepted: 10/09/2020] [Indexed: 11/16/2022]
Abstract
The purpose of this study was to evaluate the clinical efficacy and safety of patient-specific additive-manufactured CaOSiO2-P2O5-B2O3 glass-ceramic (BGS-7) implants for reconstructing zygomatic bone defects at a 6-month follow-up. A prospective, single-arm, single-center, clinical trial was performed on patients with obvious zygoma defects who needed and wanted reconstruction. The primary outcome variable was a bone fusion between the implant and the bone evaluated by computed tomography (CT) at 6 months post surgery. Secondary outcomes, including implant immobilization, satisfaction assessment, osteolysis, subsidence of the BGS-7 implant, and safety, were assessed. A total of eight patients were enrolled in the study. Two patients underwent simultaneous reconstruction of the left and right malar defects using a BGS-7 3D printed implant. Cone beam CT analysis showed that bone fusion at 6 months after surgery was 100%. We observed that the average fusion rate was 76.97%. Osteolysis around 3D printed BGS-7 implants was not observed. The mean distance displacement of all 10 implants was 0.4149 mm. Our study showed no adverse event in any of the cases. The visual analog scale score for satisfaction was 9. All patients who enrolled in this trial were aesthetically and functionally satisfied with the surgical results. In conclusion, this study demonstrates the safety and promising value of patient-specific 3D printed BGS-7 implants as a novel facial bone reconstruction method.
Collapse
Affiliation(s)
- Ui-Lyong Lee
- Department of Oral and Maxillofacial Surgery, Chung-Ang University Hospital, Soeul 06973, Korea
- Chung-Ang 3D Craniofacial Research Society, Chun-Ang University, Seoul 06974, Korea
- Correspondence: (U.-L.L.); (W.-C.C.)
| | - Jun-Young Lim
- CGbio 3D Innovation Center, Seongnam-si 13211, Korea; (J.-Y.L.); (S.-N.P.); (B.-H.C.)
| | - Sung-Nam Park
- CGbio 3D Innovation Center, Seongnam-si 13211, Korea; (J.-Y.L.); (S.-N.P.); (B.-H.C.)
| | - Byoung-Hun Choi
- CGbio 3D Innovation Center, Seongnam-si 13211, Korea; (J.-Y.L.); (S.-N.P.); (B.-H.C.)
| | - Hyun Kang
- Department of Anesthesiology and Pain Medicine, Chung-Ang University College of Medicine, Seoul 06974, Korea;
| | - Won-Cheul Choi
- Chung-Ang 3D Craniofacial Research Society, Chun-Ang University, Seoul 06974, Korea
- Department of Orthodontics, Chung-Ang University Hospital, Seoul 06974, Korea
- Correspondence: (U.-L.L.); (W.-C.C.)
| |
Collapse
|
19
|
Kasper R, Winter K, Pietzka S, Schramm A, Wilde F. Biomechanical In Vitro Study on the Stability of Patient-Specific CAD/CAM Mandibular Reconstruction Plates: A Comparison Between Selective Laser Melted, Milled, and Hand-Bent Plates. Craniomaxillofac Trauma Reconstr 2020; 14:135-143. [PMID: 33995834 DOI: 10.1177/1943387520952684] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
Study Design An experimental in vitro study. Objective Plate fractures are a recurrent problem in alloplastic mandibular reconstruction. Hypothetically it can be assumed that computer-aided design (CAD)/computer-aided manufacturing (CAM) reconstruction plates have a higher stability than conventional hand-bent plates. The aim of the study was to compare additive and subtractive fabricated CAD/CAM mandibular reconstruction plates as well as conventional plates with regard to their biomechanical properties. Methods In a chewing simulator, plates of 2 conventional locking plate systems and 2 CAD/CAM-fabricated plate systems were compared. The plates were loaded in a fatigue test. The maximum number of cycles until plate fracture and the plate stiffness were compared. Results While all conventional plates fractured at a maximum load between 150 and 210 N (Newton) after a number of cycles between 40 000 and 643 000, none of the CAD/CAM plates broke despite a nearly doubled load of 330 N and 2 million cycles. Both CAD/CAM systems proved to be significantly superior to the hand-bent plates. There was no difference between the 2 CAD/CAM systems. Conclusions Concerning the risk of plate fracture, patient-specific CAD/CAM reconstruction plates appear to have a significant advantage over conventional hand-bent plates in alloplastic mandibular reconstruction.
Collapse
Affiliation(s)
- Robin Kasper
- Department of Oral and Maxillofacial Surgery, University Hospital Ulm, Ulm, Germany
| | - Karsten Winter
- Institute of Anatomy, Medical Faculty, Leipzig University, Leipzig, Germany
| | - Sebastian Pietzka
- Department of Oral and Maxillofacial Surgery, University Hospital Ulm, Ulm, Germany.,Department of Oral and Plastic Maxillofacial Surgery, Military Hospital Ulm, Ulm, Germany
| | - Alexander Schramm
- Department of Oral and Maxillofacial Surgery, University Hospital Ulm, Ulm, Germany.,Department of Oral and Plastic Maxillofacial Surgery, Military Hospital Ulm, Ulm, Germany
| | - Frank Wilde
- Department of Oral and Maxillofacial Surgery, University Hospital Ulm, Ulm, Germany.,Department of Oral and Plastic Maxillofacial Surgery, Military Hospital Ulm, Ulm, Germany
| |
Collapse
|
20
|
Bauer E, Mazul A, Zenga J, Graboyes EM, Jackson R, Puram SV, Doering M, Pipkorn P. Complications After Soft Tissue With Plate vs Bony Mandibular Reconstruction: A Systematic Review and Meta-analysis. Otolaryngol Head Neck Surg 2020; 164:501-511. [PMID: 32838614 DOI: 10.1177/0194599820949223] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
OBJECTIVE Mandibular reconstruction for segmental defects is a well-studied topic. However, there are conflicting data on the risks of delayed plate-related complications. The objective of this systematic review and meta-analysis was to assess long-term plate-related complications following reconstruction of the mandible with soft tissue and a plate as compared with immediate vascularized bony reconstruction. DATA SOURCES A medical librarian created search strategies with a combination of keywords and controlled vocabulary in Ovid Medline (1946-), Embase (1947-), Scopus (1960-), Cochrane Central Register of Controlled Trials, Cochrane Database of Systematic Reviews, and Clinicaltrials.gov. REVIEW METHODS Candidate articles were independently reviewed by 2 authors. Inclusion/exclusion criteria were uniformly applied. Articles were considered eligible if they included adequate reporting of plate extrusion and/or fracture and had follow-up ≥12 months. RESULTS A total of 2379 patients were included. The risk of plate fracture was low in cases of soft tissue with a plate (5%; 95% CI, 0.03-0.08) and osseous reconstruction (1%). The risk of extrusion following soft tissue and plate reconstruction was 20% (95% CI, 0.15-0.27). In the osseous reconstruction group, the risk of extrusion was 10% (95% CI, 0.06-0.18). Revision surgery was performed twice as often following soft tissue with a plate as compared with vascularized bony reconstruction (32% [95% CI, 0.25-0.40] vs 14% [95% CI, 0.09-0.21], respectively). CONCLUSION Delayed plate-related complications remain a significant problem following segmental defect reconstruction. Soft tissue and plate reconstruction techniques may increase the risk of plate removal and revision surgery.
Collapse
Affiliation(s)
- Eric Bauer
- Department of Otolaryngology-Head and Neck Surgery, Washington University, St Louis, Missouri, USA
| | - Angela Mazul
- Department of Otolaryngology-Head and Neck Surgery, Washington University, St Louis, Missouri, USA
| | - Joseph Zenga
- Department of Otolaryngology-Head and Neck Surgery, Medical College of Wisconsin, Milwaukee, Wisconsin, USA
| | - Evan M Graboyes
- Department of Otolaryngology-Head and Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Ryan Jackson
- Department of Otolaryngology-Head and Neck Surgery, Washington University, St Louis, Missouri, USA
| | - Sidharth V Puram
- Department of Otolaryngology-Head and Neck Surgery, Washington University, St Louis, Missouri, USA
| | - Michelle Doering
- Bernard Becker Medical Library, School of Medicine, Washington University, St Louis, Missouri, USA
| | - Patrik Pipkorn
- Department of Otolaryngology-Head and Neck Surgery, Washington University, St Louis, Missouri, USA
| |
Collapse
|
21
|
Peters F, Kniha K, Möhlhenrich SC, Bock A, Hölzle F, Modabber A. Evaluation of a novel osteosynthesis plate system for mandibular defects. Br J Oral Maxillofac Surg 2020; 58:e109-e114. [PMID: 32800607 DOI: 10.1016/j.bjoms.2020.07.018] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2020] [Accepted: 07/16/2020] [Indexed: 11/17/2022]
Abstract
Continuity defects of the jaw can be reconstructed with titanium plates or microvascular bone flaps; osteosynthesis plates are necessary for both. In this study we performed a retrospective review of patients treated with Medartis MODUS® Mandible Trauma/Reco 2.0-2.5, TriLock bridging plates, mandibulectomy and soft tissue free flap or reconstruction with a bony free flap and TriLock mandibular plates from the same system from January 2015 to August 2019. The variables recorded were sex, age, diagnosis, radiotherapy, date of implantation, date of explantation or death of patient, size of mandibular defect, Jewer classification of defect, number of screws used, segments of bony reconstruction, screws per segment, plate exposure, plate breakage, and pseudarthrosis. The bridging plate group consisted of 41 patients, while the mandibular plate group consisted of 24 patients. The percentage of plate exposure was 17.07% for the bridging plate group and 4.17% for the mandibular plate group. Plate breakage was 0 in both groups. Pseudarthrosis was 4.17% in the mandibular plate group. In the bridging plate group, an anterolateral thigh flap covered all exposures. Of 7 plate exposures, 4 were found in a C defect. The complication rate of the investigated plates was lower than the complication rates of other plate systems.
Collapse
Affiliation(s)
- F Peters
- Department of Oral, Maxillofacial and Facial Plastic Surgery, School of Medicine, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074 Aachen Germany.
| | - K Kniha
- Department of Oral, Maxillofacial and Facial Plastic Surgery, School of Medicine, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074 Aachen Germany
| | - S C Möhlhenrich
- Department of Orthodontics, University Witten/Herdecke, Private Universität Witten/Herdecke GmbH, Alfred-Herrhausen-Straße 45, 58448 Witten, Germany
| | - A Bock
- Department of Oral, Maxillofacial and Facial Plastic Surgery, School of Medicine, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074 Aachen Germany
| | - F Hölzle
- Department of Oral, Maxillofacial and Facial Plastic Surgery, School of Medicine, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074 Aachen Germany
| | - A Modabber
- Department of Oral, Maxillofacial and Facial Plastic Surgery, School of Medicine, University Hospital RWTH Aachen, Pauwelsstraße 30, 52074 Aachen Germany
| |
Collapse
|
22
|
Almansoori AA, Choung HW, Kim B, Park JY, Kim SM, Lee JH. Fracture of Standard Titanium Mandibular Reconstruction Plates and Preliminary Study of Three-Dimensional Printed Reconstruction Plates. J Oral Maxillofac Surg 2020; 78:153-166. [DOI: 10.1016/j.joms.2019.07.016] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2019] [Revised: 06/21/2019] [Accepted: 07/21/2019] [Indexed: 10/26/2022]
|
23
|
Hirohata H, Yanagawa T, Takaoka S, Yamagata K, Sasaki K, Shibuya Y, Uchida F, Fukuzawa S, Tabuchi K, Hasegawa S, Ishibashi-Kanno N, Sekido M, Bukawa H. A small number of residual teeth after the mandibular resection of oral cancer is associated with titanium reconstruction plate exposure. Clin Exp Dent Res 2019; 5:469-475. [PMID: 31687179 PMCID: PMC6820575 DOI: 10.1002/cre2.208] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2019] [Revised: 04/24/2019] [Accepted: 05/18/2019] [Indexed: 12/03/2022] Open
Abstract
Objective Reconstruction plates are used to treat patients with a segmental mandibular defect after oral cancer surgery. Reconstruction plate failure analysis has rarely focused on occlusion, which conducts a mechanical force to the mandible and the plate. To determine the prognostic factors, we retrospectively evaluated patients who underwent reconstruction of a mandibular segmental defect with a reconstruction plate and assessed the number of residual paired teeth. Material and Methods From among 390 patients with oral cancer who visited University of Tsukuba Hospital (Tsukuba, Japan) between 2007 and 2017, we selected and analyzed the data of 37 patients who underwent segmental resection of the mandible and reconstruction with reconstruction plates. Prognostic factors evaluated were patient age, sex, TNM classification, plate manufacturer, treatment with radiotherapy or chemotherapy, whether the patient had diabetes or smoked, and whether the patient had a small number of residual paired teeth, plate length, and use of a fibular‐free flap. Among these 37 patients, eight reconstruction plates had intraoral or extraoral exposure and were removed in 5 years. Results Kaplan–Meier and log‐rank analyses revealed that the prognosis for the 5‐year plate exposure‐free rate was significantly poorer for patients with a small number of residual teeth than for patients with no teeth or those with a large number of residual teeth (.01). Univariate Cox regression analysis revealed that a small number of residual teeth was a significant prognostic factor in the loss of a reconstruction plate (hazard ratio: 5.63; 95% confidence interval [1.10, 25.85]; .04). Conclusions A small number of residual teeth after the segmental resection of oral cancer is significantly involved in reconstruction plate survival and may be important in predicting reconstruction plate prognosis.
Collapse
Affiliation(s)
- Hiromi Hirohata
- Oral and Maxillofacial Surgery, Clinical Sciences, Graduate School of Comprehensive Human Sciences University of Tsukuba Tsukuba Japan.,Department of Oral and Maxillofacial Surgery Tsukuba Central Hospital Ushiku Japan
| | - Toru Yanagawa
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine University of Tsukuba Tsukuba Japan.,Department of Oral and Maxillofacial Surgery Ibaraki Prefectural Central Hospital Kasama Japan
| | - Shohei Takaoka
- Oral and Maxillofacial Surgery, Clinical Sciences, Graduate School of Comprehensive Human Sciences University of Tsukuba Tsukuba Japan
| | - Kenji Yamagata
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine University of Tsukuba Tsukuba Japan
| | - Kaoru Sasaki
- Department of Plastic and Reconstruction Surgery, Faculty of Medicine University of Tsukuba Tsukuba Japan
| | - Yoichiro Shibuya
- Department of Plastic and Reconstruction Surgery, Faculty of Medicine University of Tsukuba Tsukuba Japan
| | - Fumihiko Uchida
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine University of Tsukuba Tsukuba Japan
| | - Satoshi Fukuzawa
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine University of Tsukuba Tsukuba Japan
| | - Katsuhiko Tabuchi
- Department of Neurohealth Innovation, Institute for Biomedical Sciences Interdisciplinary Cluster for Cutting Edge Research, Department of Molecular & Cellular Physiology Shinshu University School of Medicine Matsumoto Japan
| | - Shogo Hasegawa
- Department of Oral and Maxillofacial Surgery, Department of Maxillofacial Surgery, School of Dentistry Aichi Gakuin University Nagoya Japan
| | - Naomi Ishibashi-Kanno
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine University of Tsukuba Tsukuba Japan
| | - Mitsuru Sekido
- Department of Plastic and Reconstruction Surgery, Faculty of Medicine University of Tsukuba Tsukuba Japan
| | - Hiroki Bukawa
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine University of Tsukuba Tsukuba Japan
| |
Collapse
|
24
|
Gruichev D, Yovev T, Kniha K, Möhlhenrich S, Goloborodko E, Lethaus B, Hölzle F, Modabber A. Evaluation of alloplastic mandibular reconstruction combined with a radial forearm flap compared with a vastus lateralis myocutaneous flap as the first approach to two-stage rehabilitation in advanced oral cancer. Br J Oral Maxillofac Surg 2019; 57:435-441. [DOI: 10.1016/j.bjoms.2019.03.020] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2018] [Accepted: 03/29/2019] [Indexed: 11/26/2022]
|
25
|
Awad ME, Altman A, Elrefai R, Shipman P, Looney S, Elsalanty M. The use of vascularized fibula flap in mandibular reconstruction; A comprehensive systematic review and meta-analysis of the observational studies. J Craniomaxillofac Surg 2019; 47:629-641. [PMID: 30782453 DOI: 10.1016/j.jcms.2019.01.037] [Citation(s) in RCA: 42] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2018] [Revised: 12/11/2018] [Accepted: 01/25/2019] [Indexed: 11/17/2022] Open
Abstract
BACKGROUND Vascularized fibular flaps are considered the gold standard for the reconstruction of segmental defects in the mandible. This review compares the complication and success rates of these techniques between primary and secondary reconstruction, as well as between lateral and antero-lateral defects. TYPE OF STUDIES REVIEWED A systematic review and meta-analysis were conducted according to PRISMA protocol and the Cochrane Handbook for Systematic Reviews of Interventions. The authors performed an independent comprehensive search using PubMed, Ovid MEDLINE, Web of Science, the Cochrane Central Register of Controlled Trials, ClinicalTrials.gov and COS Conference Papers Index according to established inclusion and exclusion criteria. The methodological index for nonrandomized studies (MINORS) was used to assess the quality of the included studies. Meta-analysis was conducted to compare the type of reconstruction and location of the defect. RESULTS Seventy-eight studies, involving 2461 patients, were eligible. 83.7% of the included patient received primary reconstruction with vascularized fibular flap. The overall flap success rate was 93%. There was improvement in MINORS quality score over time with positive correlation with the publication year (r = 0.5549, P < 0.0001, CI 0.3693 to 0.6979). Meta-analysis indicated no significant association in flap success between primary and secondary reconstruction, or lateral and antero-lateral defects. CONCLUSION Based on the available studies, this review found no evidence of difference in success or complication rates between primary and secondary reconstruction or between lateral and anterolateral defects. High-quality clinical studies are required to analyze the outcome of these techniques, especially regarding the impact of chemotherapy, radiation therapy, implant-supported dental prostheses, and preoperative planning, on the outcome of reconstruction.
Collapse
Affiliation(s)
- Mohamed E Awad
- Oral Biology Department, Dental College of Georgia, Augusta University, Augusta, GA, USA
| | - Amara Altman
- Dental College of Georgia, Augusta University, Augusta, GA, USA
| | | | - Peter Shipman
- Robert B. Greenblatt M.D. Library, Augusta University, Augusta, GA, USA
| | - Stephen Looney
- Department of Biostatistics, Augusta University, Augusta, GA, USA
| | - Mohammed Elsalanty
- Oral Biology Department, Dental College of Georgia, Augusta University, Augusta, GA, USA.
| |
Collapse
|
26
|
Prevention of Mandible Reconstruction Plate Exposure by Costal Cartilage Wrapping. PLASTIC AND RECONSTRUCTIVE SURGERY-GLOBAL OPEN 2017; 5:e1438. [PMID: 28894659 PMCID: PMC5585432 DOI: 10.1097/gox.0000000000001438] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2017] [Accepted: 06/13/2017] [Indexed: 11/26/2022]
Abstract
After mandibulectomy in cancer surgery, reconstruction is often performed with a reconstruction plate covered with a soft-tissue free flap in patients in poor condition. However, the rate of complications for mandibular reconstruction is higher with a reconstruction plate than with vascularized bone grafts. We have developed a costal cartilage wrapping method to prevent exposure of the mandible reconstruction plate. The eighth costal cartilage was removed and split into 2 pieces to wrap around the reconstruction plate. In our case, the artificial plate wrapped with costal cartilage graft was not exposed and the skin over the plate did not become atrophic over 27 months follow-up even after irradiation. Wrapping around an artificial reconstruction plate with autologous costal cartilage grafts may be more effective than using only a flap covering to prevent exposure of the plate after tumor ablation and radiation therapy.
Collapse
|
27
|
Gutwald R, Jaeger R, Lambers FM. Customized mandibular reconstruction plates improve mechanical performance in a mandibular reconstruction model. Comput Methods Biomech Biomed Engin 2016; 20:426-435. [PMID: 27887036 PMCID: PMC5359746 DOI: 10.1080/10255842.2016.1240788] [Citation(s) in RCA: 49] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
The purpose of this paper was to analyze the biomechanical performance of customized mandibular reconstruction plates with optimized strength. The best locations for increasing bar widths were determined with a sensitivity analysis. Standard and customized plates were mounted on mandible models and mechanically tested. Maximum stress in the plate could be reduced from 573 to 393 MPa (−31%) by increasing bar widths. The median fatigue limit was significantly greater (p < 0.001) for customized plates (650 ± 27 N) than for standard plates (475 ± 27 N). Increasing bar widths at case-specific locations was an effective strategy for increasing plate fatigue performance.
Collapse
Affiliation(s)
- Ralf Gutwald
- a Department of Oral and Maxillofacial Surgery , University Hospital of Freiburg , Freiburg , Germany
| | - Raimund Jaeger
- b Fraunhofer Institute for Mechanics of Materials IWM , Polymer Tribology & Biomedical Materials - Group , Freiburg , Germany
| | | |
Collapse
|
28
|
Computer-Assisted Designed and Manufactured Procedures Facilitate the Lingual Application of Mandible Reconstruction Plates. J Oral Maxillofac Surg 2016; 74:1879-95. [DOI: 10.1016/j.joms.2016.03.015] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2015] [Revised: 02/29/2016] [Accepted: 03/14/2016] [Indexed: 11/23/2022]
|
29
|
Lee UL, Kwon JS, Woo SH, Choi YJ. Simultaneous Bimaxillary Surgery and Mandibular Reconstruction With a 3-Dimensional Printed Titanium Implant Fabricated by Electron Beam Melting: A Preliminary Mechanical Testing of the Printed Mandible. J Oral Maxillofac Surg 2016; 74:1501.e1-1501.e15. [DOI: 10.1016/j.joms.2016.02.031] [Citation(s) in RCA: 27] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2015] [Revised: 02/26/2016] [Accepted: 02/26/2016] [Indexed: 11/25/2022]
|
30
|
Reitemeier B, Schöne C, Lesche R, Lauer G, Schulz MC, Markwardt J. Contour identical implants to bridge mandibular continuity defects--individually generated by LaserCUSING®--A feasibility study in animal cadavers. Head Face Med 2016; 12:17. [PMID: 27066830 PMCID: PMC4827175 DOI: 10.1186/s13005-016-0114-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2015] [Accepted: 03/30/2016] [Indexed: 11/10/2022] Open
Abstract
Background Ablative tumor surgery often results in continuity defects of the mandible. When an immediate reconstruction using autologous bone grafts is not possible the bridging of the defects with a variety of bridging plates might be achieved. However, those bridging plates have the risk of plate fractures or exposure. Customized titanium implants manufactured using CAD/CAM and the LaserCUSING® technique might be an alternative. Methods In the present study, computed tomographies (CT) of porcine cadaver mandibles were generated and transferred into DICOM data. Following, different continuity defects were surgically created in the mandibles. Based on the DICOM data customized titanium implants were manufactured using CAD/CAM procedures and the LaserCUSING® technique. The implants were fixed to the remaining stumps with screws. Subsequently, the accuracy of the reconstructed mandibles was tested using plaster casts. Results The workflow from the CT to the application of the customized implants was proved to be practicable. Furthermore, a stable fixation of the customized implant to the remaining stumps could be achieved. The control of the accuracy showed no frictions or obstacles. Conclusion The customized titanium implant seems to be a promising approach to bridge continuity defects of the mandible whenever an immediate reconstruction with autologous bone is not possible.
Collapse
Affiliation(s)
- Bernd Reitemeier
- Department of Prosthetic Dentistry, Faculty of Medicine "Carl Gustav Carus", Technische Universität Dresden, Fetscherstr. 74, 01307, Dresden, Germany
| | - Christine Schöne
- Department of Design Engineering/CAD, Institute of Machine Elements and Machine, Technische Universität Dresden, George-Bähr-Str. 3c, 01069, Dresden, Germany
| | - Raoul Lesche
- H&E Produktentwicklung GmbH, Hofmann und Engel, Kunzer Marktweg 13, 01468, Moritzburg, Germany
| | - Günter Lauer
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine "Carl Gustav Carus", Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Matthias C Schulz
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine "Carl Gustav Carus", Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany
| | - Jutta Markwardt
- Department of Oral and Maxillofacial Surgery, Faculty of Medicine "Carl Gustav Carus", Technische Universität Dresden, Fetscherstraße 74, 01307, Dresden, Germany.
| |
Collapse
|
31
|
Fanzio PM, Chang KP, Chen HH, Hsu HH, Gorantla V, Solari MG, Kao HK. Plate Exposure After Anterolateral Thigh Free-Flap Reconstruction in Head and Neck Cancer Patients With Composite Mandibular Defects. Ann Surg Oncol 2015; 22:3055-3060. [DOI: 10.1245/s10434-014-4322-1] [Citation(s) in RCA: 29] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/30/2023]
|
32
|
Fang SL, Wang YY, Chen WL, Zhang DM. Use of Extended Vertical Lower Trapezius Island Myocutaneous Flaps to Cover Exposed Reconstructive Plates. J Oral Maxillofac Surg 2014; 72:2092.e1-7. [DOI: 10.1016/j.joms.2014.06.420] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/26/2014] [Revised: 06/02/2014] [Accepted: 06/05/2014] [Indexed: 10/25/2022]
|
33
|
Markwardt J, Weber T, Modler N, Sembdner P, Lesche R, Schulz MC, Reitemeier B. One vs. two piece customized implants to reconstruct mandibular continuity defects: A preliminary study in pig cadavers. J Craniomaxillofac Surg 2014; 42:790-5. [DOI: 10.1016/j.jcms.2013.11.013] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/12/2013] [Revised: 08/24/2013] [Accepted: 11/04/2013] [Indexed: 10/26/2022] Open
|
34
|
Chung JH, Yoon ES, Park SH, Lee BI, Kim HS, You HJ. Comparison of Mechanical Stability between Fibular Free Flap Reconstruction versus Locking Mandibular Reconstruction Plate Fixation. Arch Craniofac Surg 2014; 15:75-81. [PMID: 28913195 PMCID: PMC5556818 DOI: 10.7181/acfs.2014.15.2.75] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2014] [Revised: 07/20/2014] [Accepted: 08/01/2014] [Indexed: 12/02/2022] Open
Abstract
Background The fibular free flap has been used as the standard methods of segmental mandibular reconstruction. The objective of mandibular reconstruction not only includes restored continuity of the mandible but also the recovery of optimal function. This paper emphasizes the advantage of the fibular free flap reconstruction over that of locking mandibular reconstruction plate fixation. Methods The hospital charts of all patients (n=20) who had a mandibular reconstruction between 1994 and 2013 were retrospectively reviewed. Eight patients had plate-only fixation of the mandible, and the remaining 12 had vascularized fibular free flap reconstruction. Complications and outcomes were reviewed and compared between the 2 groups via statistical analysis. Results Overall complication rates were significantly lower in the fibular flap group (8.3%) than in the plate fixation group (87.5%; p =0.001). Most (7/8) patients in the plate fixation group had experienced plate-related late complications, including plate fracture or exposure. In the fibular flap group, no complications were observed, except for a single case of donor-site wound dehiscence (1/12). Conclusion The fibular free flap provides a more stable support and additional soft tissue support for the plate, thereby minimizing the risk of plate-related complications. Fibular free flap is the most reliable option for mandibular reconstruction, and we believe that the flap should be performed primarily whenever possible.
Collapse
Affiliation(s)
- Jae-Hyun Chung
- Department of Plastic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea
| | - Eul-Sik Yoon
- Department of Plastic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea
| | - Seung-Ha Park
- Department of Plastic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea
| | - Byung-Il Lee
- Department of Plastic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea
| | - Hyon-Surk Kim
- Department of Plastic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea
| | - Hi-Jin You
- Department of Plastic Surgery, Korea University Anam Hospital, Korea University College of Medicine, Seoul, Korea
| |
Collapse
|
35
|
Local and systemic risk factors influencing the long-term success of angular stable alloplastic reconstruction plates of the mandible. J Craniomaxillofac Surg 2014; 42:e271-6. [DOI: 10.1016/j.jcms.2013.10.004] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2013] [Revised: 07/27/2013] [Accepted: 10/08/2013] [Indexed: 11/17/2022] Open
|
36
|
Li P, Shen L, Li J, Liang R, Tian W, Tang W. Optimal design of an individual endoprosthesis for the reconstruction of extensive mandibular defects with finite element analysis. J Craniomaxillofac Surg 2014; 42:73-8. [DOI: 10.1016/j.jcms.2013.02.005] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2012] [Revised: 02/18/2013] [Accepted: 02/19/2013] [Indexed: 10/27/2022] Open
|
37
|
Markwardt J, Sembdner P, Lesche R, Jung R, Spekl K, Mai R, Schulz M, Reitemeier B. Experimental findings on customized mandibular implants in Göttingen minipigs – A pilot study. Int J Surg 2014; 12:60-6. [DOI: 10.1016/j.ijsu.2013.10.011] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2013] [Revised: 10/13/2013] [Accepted: 10/24/2013] [Indexed: 11/28/2022]
|
38
|
Alloplastic mandibular reconstruction: a systematic review and meta-analysis of the current century case series. Plast Reconstr Surg 2013; 132:413e-427e. [PMID: 23985653 DOI: 10.1097/prs.0b013e31829ad0d9] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
BACKGROUND Alloplastic mandibular reconstruction remains insufficiently predictable, with no systematic reviews to assess its scope and limitations. METHODS The PubMed, CINAHL, EMBASE, and Web of Science databases were searched for English study reports, published in the current century, of mere alloplastic surgical reconstruction of mandibular ablative defects. RESULTS In 14 articles, there were 944 patients, with a median age of 58.7 years (interquartile range, 53.2 to 62 years); 58.7 percent (interquartile range, 66.7 to 78.6 percent) were male. Cases of squamous cell carcinoma per study constituted 93.5 percent (interquartile range, 81.5 to 100 percent). Defects were mostly lateral (Boyd classification) (60.5 percent; interquartile range, 56.2 to 62 percent) and received mostly conventional bridging plates (in 64.3 percent of the studies) and pedicled flaps (45.3 percent; interquartile range, 37.1 to 58.3 percent); 60.7 percent (interquartile range, 53.5 to 58.8 percent) received adjuvant therapy. At 32-month follow-up, the complication and failure rates were 40.1 percent (interquartile range, 26.7 to 58.6 percent) and 30.8 percent (interquartile range, 11.7 to 48.1 percent), respectively. The overall survival rate was 55 percent (interquartile range, 27.8 to 74 percent). Radiotherapy seemed to be a relative risk factor for complications (1.387; p = 0.014) and plate loss (1.585; p = 0.006). Crossing the midline seemed to be a relative risk factor for plate exposure (1.533; p = 0.000) and overall complications (1.385; p = 0.002). CONCLUSIONS The results should be generalized cautiously. Alloplastic reconstructive surgery faces a remarkable lack of evidence. Relatively high complication and failure rates are areas of further concern.
Collapse
|
39
|
Li P, Tang Y, Li J, Shen L, Tian W, Tang W. Establishment of sequential software processing for a biomechanical model of mandibular reconstruction with custom-made plate. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2013; 111:642-649. [PMID: 23810232 DOI: 10.1016/j.cmpb.2013.05.024] [Citation(s) in RCA: 19] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/01/2013] [Revised: 05/27/2013] [Accepted: 05/29/2013] [Indexed: 06/02/2023]
Abstract
The aim of this study is to describe the sequential software processing of computed tomography (CT) dataset for reconstructing the finite element analysis (FEA) mandibular model with custom-made plate, and to provide a theoretical basis for clinical usage of this reconstruction method. A CT scan was done on one patient who had mandibular continuity defects. This CT dataset in DICOM format was imported into Mimics 10.0 software in which a three-dimensional (3-D) model of the facial skeleton was reconstructed and the mandible was segmented out. With Geomagic Studio 11.0, one custom-made plate and nine virtual screws were designed. All parts of the reconstructed mandible were converted into NURBS and saved as IGES format for importing into pro/E 4.0. After Boolean operation and assembly, the model was switched to ANSYS Workbench 12.0. Finally, after applying the boundary conditions and material properties, an analysis was performed. As results, a 3-D FEA model was successfully developed using the softwares above. The stress-strain distribution precisely indicated biomechanical performance of the reconstructed mandible on the normal occlusion load, without stress concentrated areas. The Von-Mises stress in all parts of the model, from the maximum value of 50.9MPa to the minimum value of 0.1MPa, was lower than the ultimate tensile strength. In conclusion, the described strategy could speedily and successfully produce a biomechanical model of a reconstructed mandible with custom-made plate. Using this FEA foundation, the custom-made plate may be improved for an optimal clinical outcome.
Collapse
Affiliation(s)
- Peng Li
- Department of Oral and Maxillofacial Surgery, West China College of Stomatology, Sichuan University, No. 14, 3rd Section, Renmin South Road, Chengdu 610041, PR China
| | | | | | | | | | | |
Collapse
|
40
|
The modular endoprosthesis for mandibular body replacement. Part 2: Finite element analysis of endoprosthesis reconstruction of the mandible. J Craniomaxillofac Surg 2012; 40:e487-97. [DOI: 10.1016/j.jcms.2012.03.010] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2011] [Revised: 03/12/2012] [Accepted: 03/12/2012] [Indexed: 11/24/2022] Open
|
41
|
Prevention points for plate exposure in the mandibular reconstruction. J Craniomaxillofac Surg 2012; 40:e310-4. [DOI: 10.1016/j.jcms.2012.01.013] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2011] [Revised: 01/30/2012] [Accepted: 01/30/2012] [Indexed: 11/23/2022] Open
|
42
|
|
43
|
Irjala H, Kinnunen I, Aitasalo K. Mandibular reconstruction using free bone flap after preoperative chemoradiation. Eur Arch Otorhinolaryngol 2011; 269:1513-8. [DOI: 10.1007/s00405-011-1795-4] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2011] [Accepted: 09/16/2011] [Indexed: 11/28/2022]
|