1
|
Flores G, Lago BV, Caetano AR, Silva J, Marques V, Brandão-Mello CE, Amendola-Pires M, Pilotto J, Lewis-Ximenez L, Villar LM. Dried blood spot as alternative specimen for molecular epidemiology studies among HCV/HIV coinfected patients. Braz J Infect Dis 2025; 29:104512. [PMID: 39985934 PMCID: PMC11893293 DOI: 10.1016/j.bjid.2025.104512] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/30/2024] [Revised: 12/23/2024] [Accepted: 01/17/2025] [Indexed: 02/24/2025] Open
Abstract
BACKGROUND Immunodeficiency Virus (HIV) and Hepatitis C Virus (HCV) share the same routes of transmission, therefore, co-infection by both viruses represents a challenge to the goal of eliminating viral hepatitis as a public health threat. There are an estimated 2.3 million people living with HIV/HCV worldwide. Most of these cases affect vulnerable populations located in places with low infrastructure. Because of this, the use of alternative samples such as Dried Blood on Spot (DBS) would facilitate access to diagnosis and HCV treatment. The aim of this study is to evaluate the HCV genetic variability in HIV/HCV individuals by correlating paired serum and DBS samples. METHODS A total of 14 HIV/HCV individuals, recruited from reference outpatient clinics in the city of Rio de Janeiro/Brazil, were included. From them, 64 % were man, mean of age 54±7. HCV RNA from both serum and DBS samples was RT-PCR amplified and sequenced with HCV NS5B-specific oligonucleotides. All positive samples were submitted to phylogenetic analysis. RESULTS Serum mean HCV load was 6.2 ± 0.5 log IU/mL. All patients presented undetectable HIV RNA. The distribution of HCV genotypes/subgenotypes was 1a (4/14); 1b (5/14); 3a (4/14); and 4d (1/14). Most paired serum and DBS samples showed concordant results (genetic distance: 0.0 to 0.16). One individual showed discordance in the subtypes between serum and DBS. Three individuals presented the 316 N Resistance Associated Mutation (RAS) in both serum and DBS. CONCLUSION Our results demonstrate the applicability of DBS for HCV molecular tracking in HIV/HCV coinfected patients for viral genomic surveillance in key and vulnerable populations.
Collapse
Affiliation(s)
- Geane Flores
- Instituto Oswaldo Cruz (Fiocruz), Laboratório de Hepatites Virais, Rio de Janeiro, RJ, Brazil
| | - Barbara Vieira Lago
- Instituto Oswaldo Cruz (Fiocruz), Laboratório de Hepatites Virais, Rio de Janeiro, RJ, Brazil; Instituto de Tecnologia Imunobiológica (Biomanguinhos), Rio de Janeiro, RJ, Brazil.
| | - Amanda R Caetano
- Instituto Oswaldo Cruz (Fiocruz), Laboratório de Hepatites Virais, Rio de Janeiro, RJ, Brazil
| | - Jessica Silva
- Instituto Oswaldo Cruz (Fiocruz), Laboratório de Hepatites Virais, Rio de Janeiro, RJ, Brazil
| | - Vanessa Marques
- Instituto Oswaldo Cruz (Fiocruz), Laboratório de Hepatites Virais, Rio de Janeiro, RJ, Brazil
| | | | - Marcia Amendola-Pires
- Universidade Federal do Rio de Janeiro State, Hospital Gaffree and Guinle, Rio de Janeiro, RJ, Brazil
| | - Jose Pilotto
- Instituto Oswaldo Cruz (Fiocruz), Laboratório de AIDS e Imunologia Molecular, Rio de Janeiro, RJ, Brazil
| | - Lia Lewis-Ximenez
- Instituto Oswaldo Cruz (Fiocruz), Laboratório de Hepatites Virais, Rio de Janeiro, RJ, Brazil
| | - Livia Melo Villar
- Instituto Oswaldo Cruz (Fiocruz), Laboratório de Hepatites Virais, Rio de Janeiro, RJ, Brazil
| |
Collapse
|
2
|
Babigumira JB, Karichu JK, Clark S, Cheng MM, Garrison LP, Maniecki MB, Hamid SS. Assessing the potential cost-effectiveness of centralised versus point-of-care testing for hepatitis C virus in Pakistan: a model-based comparison. BMJ Open 2023; 13:e066770. [PMID: 37142306 PMCID: PMC10163545 DOI: 10.1136/bmjopen-2022-066770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 05/06/2023] Open
Abstract
OBJECTIVES Pakistan has a hepatitis C virus (HCV) infection prevalence of 6%-9% and aims to achieve World Health Organisation (WHO) targets for elimination of HCV by the year 2030. We aim to evaluate the potential cost-effectiveness of a reference laboratory-based (centralised laboratory testing; CEN) confirmatory testing approach versus a molecular near-patient point-of-care (POC) confirmatory approach to screen the general population for HCV in Pakistan. STUDY DESIGN We used a decision tree-analytic model from a governmental (formal healthcare sector) perspective. STUDY SETTING Individuals were assumed to be initially screened with an anti-HCV test at home, followed by POC nucleic acid test (NAT) at nearby district hospitals or followed by NAT at centralised laboratories. PARTICIPANTS We included the general testing population for chronic HCV in Pakistan. INTERVENTION Screening with an anti-HCV antibody test (Anti-HCV) followed by either POC NAT (Anti-HCV-POC), or reference laboratory NAT (Anti-HCV-CEN), was compared, using data from published literature and the Pakistan Ministry of Health. MEASURES Outcome measures included: number of HCV infections identified per year, percentage of individuals correctly classified, total costs, average costs per individual tested, and cost-effectiveness (assessed as cost per additional HCV infection identified). Sensitivity analysis was also performed. RESULTS At a national level (25 million annual screening tests), the Anti-HCV-CEN strategy would identify 142 406 more HCV infections in 1 year and increase correct classification of individuals by 0.57% compared with the Anti-HCV-POC strategy. The total annual cost of HCV testing was reduced using the Anti-HCV-CEN strategy by US$7.68 million (US$0.31/person). Thus, incrementally, the Anti-HCV-CEN strategy costs less and identifies more HCV infections than Anti-HCV-POC. The incremental difference in HCV infections identified was most sensitive to the probability of loss to follow-up (for POC confirmatory NAT). CONCLUSIONS Anti-HCV-CEN would provide the best value for money when scaling up HCV testing in Pakistan.
Collapse
Affiliation(s)
- Joseph B Babigumira
- Saw Swee Hock School of Public Health, National University of Singapore, Singapore
| | | | - Samantha Clark
- The Comparative Health Outcomes, Policy, and Economics (CHOICE) Institute, University of Washington Seattle Campus, Seattle, Washington, USA
| | - Mindy M Cheng
- Roche Molecular Systems Inc, Pleasanton, California, USA
| | - Louis P Garrison
- The Comparative Health Outcomes, Policy, and Economics (CHOICE) Institute, University of Washington Seattle Campus, Seattle, Washington, USA
- VeriTech Corporation, Mercer Island, Washington, USA
| | | | | |
Collapse
|
3
|
Villar LM, de Lima MP, Cruz HM, de Paula VS, Scalioni LDP, Flores GL, Carvalho-Costa FA, Parente CC, Coelho MRCD, de Albuquerque ACC, Milagres FAP, Cruz MS, Andrade TM, Motta-Castro ARC, da Mota JC, Lewis-Ximenez LL, Bastos FI. Feasibility of dried blood spot for hepatitis C diagnosis in vulnerable subjects and people living in remote areas from Brazil. BMC Infect Dis 2022; 22:804. [PMID: 36303137 PMCID: PMC9615222 DOI: 10.1186/s12879-022-07717-4] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2021] [Accepted: 09/01/2022] [Indexed: 11/10/2022] Open
Abstract
Background Agile, accessible and cheap diagnosis of hepatitis C virus (HCV) infection is essential to achieve the elimination of this infection, worldwide, as mandated by the World Health Organzation as part of its strategy for 2030. Dried blood spots (DBS) can be an attractive alternative for sample collection among people living in remote areas and vulnerable populations due to the less invasive collection, its biosafety, and storage & transportation of samples at room temperature.
Design This study aims to estimate the usefulness of dried blood spot samples for the diagnosis and the assessment of HCV infection rates in three different settings in Brazil. Cross-sectional analysis of a sample collection from different populations, aiming to assess the performance of the testing algorithms and respective procedures among different populations with diverse background infection rates. Methods We reported the evaluation of DBS as alternative samples for detecting anti-HCV in different groups in real life conditions: (I) Vulnerable subjects living in remote areas of Southeast, North and Northeast Brazil (n = 1464); (II) Beauticians (n = 288); (III) People who use non-injectable drugs (n = 201); (IV) patients referred to outpatient care (n = 275). Results General assay accuracy was 99%, with a weighted kappa value of 0.9, showing an excellent performance. Sensitivities ranged from 87.5% to 100.0% between groups and specificities were above 99.2%. A total of 194 individuals had HCV RNA in serum and concordance of anti-HCV detection in DBS was 98.4%. Conclusions DBS samples could be used for anti-HCV detection in different populations recruited in real life conditions and ambulatory settings, with a high overall sensitivity and specificity. Supplementary Information The online version contains supplementary material available at 10.1186/s12879-022-07717-4.
Collapse
Affiliation(s)
- Livia Melo Villar
- Laboratory of Viral Hepatitis, Oswaldo Cruz Institute, FIOCRUZ, Helio and Peggy Pereira Pavillion, Ground Floor, Room B09, v. Brasil, 4365, Manguinhos, Rio de Janeiro, RJ, 210360-040, Brazil.
| | - Marjorie Parra de Lima
- Laboratory of Viral Hepatitis, Oswaldo Cruz Institute, FIOCRUZ, Helio and Peggy Pereira Pavillion, Ground Floor, Room B09, v. Brasil, 4365, Manguinhos, Rio de Janeiro, RJ, 210360-040, Brazil
| | - Helena Medina Cruz
- Laboratory of Viral Hepatitis, Oswaldo Cruz Institute, FIOCRUZ, Helio and Peggy Pereira Pavillion, Ground Floor, Room B09, v. Brasil, 4365, Manguinhos, Rio de Janeiro, RJ, 210360-040, Brazil.,Estácio de Sá University, Resende, Rio de Janeiro, Brazil
| | | | - Leticia de Paula Scalioni
- Laboratory of Viral Hepatitis, Oswaldo Cruz Institute, FIOCRUZ, Helio and Peggy Pereira Pavillion, Ground Floor, Room B09, v. Brasil, 4365, Manguinhos, Rio de Janeiro, RJ, 210360-040, Brazil
| | - Geane Lopes Flores
- Laboratory of Viral Hepatitis, Oswaldo Cruz Institute, FIOCRUZ, Helio and Peggy Pereira Pavillion, Ground Floor, Room B09, v. Brasil, 4365, Manguinhos, Rio de Janeiro, RJ, 210360-040, Brazil
| | | | | | | | | | | | - Marcelo Santos Cruz
- Institute of Psychiatry, Federal University of Rio de Janeiro, Rio de Janeiro, Brazil
| | - Tarcisio Matos Andrade
- Department of Community and Family Health, Federal University of Bahia, SalvadorBahia, 40110-100, Brazil
| | | | - Jurema Corrêa da Mota
- Institute of Communication and Scientific Information and Technology for Health, Oswaldo Cruz Foundation, Rio de Janeiro, Brazil
| | - Lia Laura Lewis-Ximenez
- Laboratory of Viral Hepatitis, Oswaldo Cruz Institute, FIOCRUZ, Helio and Peggy Pereira Pavillion, Ground Floor, Room B09, v. Brasil, 4365, Manguinhos, Rio de Janeiro, RJ, 210360-040, Brazil
| | - Francisco Inácio Bastos
- Institute of Communication and Scientific Information and Technology for Health, Oswaldo Cruz Foundation, Rio de Janeiro, Brazil
| |
Collapse
|
4
|
da Fonseca Mendonça AC, Portilho MM, da Silva JC, Caetano AR, Lewis-Ximenez LL, Melo Villar L. Optimization of a real time PCR methodology for HCV RNA quantification in saliva samples. J Virol Methods 2022; 302:114470. [PMID: 35063589 DOI: 10.1016/j.jviromet.2022.114470] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 01/11/2022] [Accepted: 01/17/2022] [Indexed: 11/17/2022]
Abstract
Saliva may be an alternative biological specimen to expand HCV detection. This study aims to evaluate an in-house quantitative RT-PCR for HCV RNA quantification in saliva. A total of 80 individuals (56 anti-HCV/HCV RNA + and 24 negative controls) donated serum and saliva, that were tested using an in-house quantitative PCR for HCV RNA. The median viral load was 4.77 log10 copies/mL (1.04-7.0 log10 copies/mL) in serum and 2.31 log10 copies/mL (1.0-3.84 log10 copies/mL) in saliva. A sensitivity and specificity of 80 % was observed for HCV detection in saliva, which demonstrates the usefulness of in-house real-time PCR to quantify HCV RNA in saliva samples, which might increase the access of molecular diagnosis of HCV in laboratories that lack complex infrastructures for molecular testing and in individuals with poor venous access.
Collapse
Affiliation(s)
| | | | | | | | | | - Livia Melo Villar
- Viral Hepatitis Laboratory, Oswaldo Cruz Institute, Fiocruz, Rio de Janeiro, Brazil.
| |
Collapse
|
5
|
Adeboyejo K, Grosche VR, José DP, Ferreira GM, Shimizu JF, King BJ, Tarr AW, Soares MMCN, Ball JK, McClure CP, Jardim ACG. Simultaneous determination of HCV genotype and NS5B resistance associated substitutions using dried serum spots from São Paulo state, Brazil. Access Microbiol 2022; 4:000326. [PMID: 35693474 PMCID: PMC9175972 DOI: 10.1099/acmi.0.000326] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/10/2021] [Accepted: 12/30/2021] [Indexed: 11/26/2022] Open
Abstract
Hepatitis C virus (HCV) is responsible for more than 180 million infections worldwide, and about 80 % of infections are reported in Low and Middle-income countries (LMICs). Therapy is based on the administration of interferon (INF), ribavirin (RBV) or more recently Direct-Acting Antivirals (DAAs). However, amino acid substitutions associated with resistance (RAS) have been extensively described and can contribute to treatment failure, and diagnosis of RAS requires considerable infrastructure, not always locally available. Dried serum spots (DSS) sampling is an alternative specimen collection method, which embeds drops of serum onto filter paper to be transported by posting to a centralized laboratory. Here, we assessed feasibility of genotypic analysis of HCV from DSS in a cohort of 80 patients from São Paulo state Brazil. HCV RNA was detected on DSS specimens in 83 % of samples of HCV infected patients. HCV genotypes 1a, 1b, 2a, 2c and 3a were determined using the sequence of the palm domain of NS5B region, and RAS C316N/Y, Q309R and V321I were identified in HCV 1b samples. Concerning therapy outcome, 75 % of the patients who used INF +RBV as a previous protocol of treatment did not respond to DAAs, and 25 % were end-of-treatment responders. It suggests that therapy with INF plus RBV may contribute for non-response to a second therapeutic protocol with DAAs. One patient that presented RAS (V321I) was classified as non-responder, and combination of RAS C316N and Q309R does not necessarily imply in resistance to treatment in this cohort of patients. Data presented herein highlights the relevance of studying circulating variants for a better understanding of HCV variability and resistance to the therapy. Furthermore, the feasibility of carrying out genotyping and RAS phenotyping analysis by using DSS card for the potential of informing future treatment interventions could be relevant to overcome the limitations of processing samples in several location worldwide, especially in LMICs.
Collapse
Affiliation(s)
- Kazeem Adeboyejo
- NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK.,School of Life Sciences, University of Nottingham, Nottingham, UK
| | - Victória Riquena Grosche
- Institute of Biomedical Sciences, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.,Institute of Bioscience, Language and Exact Sciences, São Paulo State University, São José do Rio Preto, São Paulo, Brazil
| | | | - Giulia Magalhães Ferreira
- Institute of Biomedical Sciences, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
| | - Jacqueline Farinha Shimizu
- Institute of Biomedical Sciences, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.,Institute of Bioscience, Language and Exact Sciences, São Paulo State University, São José do Rio Preto, São Paulo, Brazil
| | - Barnabas J King
- NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK.,School of Life Sciences, University of Nottingham, Nottingham, UK.,MRC/EPSRC Nottingham Molecular Pathology Node, University of Nottingham, Nottingham, UK
| | - Alexander W Tarr
- NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK.,School of Life Sciences, University of Nottingham, Nottingham, UK.,MRC/EPSRC Nottingham Molecular Pathology Node, University of Nottingham, Nottingham, UK
| | | | - Jonathan K Ball
- NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK.,School of Life Sciences, University of Nottingham, Nottingham, UK.,MRC/EPSRC Nottingham Molecular Pathology Node, University of Nottingham, Nottingham, UK
| | - C Patrick McClure
- NIHR Nottingham Biomedical Research Centre, Nottingham University Hospitals NHS Trust and the University of Nottingham, Nottingham, UK.,School of Life Sciences, University of Nottingham, Nottingham, UK.,MRC/EPSRC Nottingham Molecular Pathology Node, University of Nottingham, Nottingham, UK
| | - Ana Carolina Gomes Jardim
- Institute of Biomedical Sciences, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil.,Institute of Bioscience, Language and Exact Sciences, São Paulo State University, São José do Rio Preto, São Paulo, Brazil
| |
Collapse
|
6
|
Carty PG, McCarthy M, O'Neill SM, De Gascun CF, Harrington P, O'Neill M, Smith SM, Teljeur C, Ryan M. Laboratory-based testing for hepatitis C infection using dried blood spot samples: A systematic review and meta-analysis of diagnostic accuracy. Rev Med Virol 2021; 32:e2320. [PMID: 34957630 DOI: 10.1002/rmv.2320] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/25/2021] [Revised: 12/11/2021] [Accepted: 12/13/2021] [Indexed: 11/10/2022]
Abstract
The use of dried blood spot (DBS) samples can facilitate the implementation of reflex testing by circumventing the need for centrifugation and freezing of venous blood samples. This systematic review assessed the accuracy of using DBS samples to diagnose chronic hepatitis C virus (HCV) infection. A comprehensive search was undertaken to identify articles published up to July 2020 evaluating the diagnostic accuracy of anti-HCV, HCV-RNA and HCV core antigen tests using DBS. Screening, data extraction, quality appraisal and Grading of Recommendations, Assessment, Development and Evaluations certainty of the evidence assessment were performed independently by two reviewers. Meta-analysis, meta-regression and sensitivity analyses were conducted. The evidence demonstrates that laboratory-based anti-HCV and HCV-RNA tests using DBS samples have high diagnostic accuracy. All comparisons were between DBS and venous samples. For the detection of anti-HCV, sensitivity was 95% (95% CI: 92%-97%) and specificity was 99% ([95% CI: 98%-99%]; n = 25; I2 = 81%; moderate certainty). For the detection of HCV-RNA, the sensitivity was 95% (95% CI: 93%-97%) and specificity was 97% ([95% CI: 94%-98%]; n = 20; I2 = 52%; moderate certainty). The sensitivity of HCV core antigen tests was 86% (95% CI: 79%-91%) and specificity was 98% ([95% CI: 94%-99%]; n = 5; I2 = 37%; low certainty) compared with HCV-RNA (the gold standard for detecting chronic HCV). DBS samples could facilitate diagnosis of chronic HCV infection as the necessary sequential tests (anti-HCV and then HCV-RNA or HCV core antigen) can be undertaken using the same blood sample. This could reduce loss of patient follow-up and support international efforts towards HCV elimination in both high and low prevalence settings.
Collapse
Affiliation(s)
- Paul G Carty
- Faculty of Medicine & Health Sciences, RCSI University of Medicine and Health Sciences, Dublin, Ireland.,Health Information and Quality Authority, Dublin, Ireland
| | | | | | - Cillian F De Gascun
- National Virus Reference Laboratory, University College Dublin, Dublin, Ireland
| | | | | | - Susan M Smith
- Department of General Practice, Health Research Board Centre for Primary Care Research, Royal College of Surgeons in Ireland, Dublin, Ireland
| | - Conor Teljeur
- Health Information and Quality Authority, Dublin, Ireland
| | - Mairin Ryan
- Health Information and Quality Authority, Dublin, Ireland.,Department of Pharmacology & Therapeutics, Trinity College Dublin, Trinity Health Sciences, St James's Hospital, Dublin, Ireland
| |
Collapse
|
7
|
De Vitis E, Ricci S, Nieddu F, Moriondo M, Cortimiglia M, Casini A, Lodi L, Indolfi G, Azzari C. Real-time polymerase chain reaction on filter paper spotted samples: a gateway to molecular diagnosis of invasive bacterial diseases for rural areas in low-income countries. Trans R Soc Trop Med Hyg 2021; 116:233-241. [PMID: 34328186 DOI: 10.1093/trstmh/trab107] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2020] [Revised: 12/25/2020] [Accepted: 07/14/2021] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Bacterial culture is the gold standard for the diagnosis of invasive bacterial diseases (IBDs) but molecular methods are more specific and sensitive. Fresh liquid samples (FLSs) show patent limitations for shipping and storage. We aimed to evaluate the sensitivity and specificity of real-time polymerase chain reaction (PCR) performed on dried sample spots (DSSs) obtained from different biological fluids compared with real-time PCR or culture performed on FLSs. METHODS FLSs positive for Streptococcus pneumoniae, Neisseria meningitidis, Haemophilus influenzae, Escherichia coli, Streptococcus pyogenes, Staphylococcus aureus, Bordetella pertussis and/or Pseudomonas aeruginosa were spotted on filter paper. Real-time PCR was performed on both FLSs and DSSs and results were compared. The stability of the DSS results over time was evaluated. RESULTS Real-time PCR performed on 114 DSSs showed a specificity of 99.1% and a sensitivity of 91.2% for IBD diagnosis. A positive correlation was found between FLS cycle threshold (Ct) and DSS Ct (r=0.84; r2=0.71) with the Pearson statistical test and Bland-Altman analysis showing that 95% of the specimens were within agreeable limits. Although we observed a trend towards signal reduction over time in the DSSs, there was no statistical evidence of an increase in Ct values. Real-time PCR on DSSs was 2.2 times more sensitive than culture. CONCLUSIONS Real-time PCR applied to DSSs may be a useful approach in different situations, such as IBD diagnosis, both for rural areas of low-income countries and family practitioners in various settings.
Collapse
Affiliation(s)
- Elisa De Vitis
- Department of Health Sciences, University of Florence and Meyer Children's University Hospital, Florence, Italy
| | - Silvia Ricci
- Department of Health Sciences, University of Florence and Meyer Children's University Hospital, Florence, Italy
| | - Francesco Nieddu
- Department of Health Sciences, University of Florence and Meyer Children's University Hospital, Florence, Italy
| | - Maria Moriondo
- Department of Health Sciences, University of Florence and Meyer Children's University Hospital, Florence, Italy
| | - Martina Cortimiglia
- Department of Health Sciences, University of Florence and Meyer Children's University Hospital, Florence, Italy
| | - Arianna Casini
- Department of Health Sciences, University of Florence and Meyer Children's University Hospital, Florence, Italy
| | - Lorenzo Lodi
- Department of Health Sciences, University of Florence and Meyer Children's University Hospital, Florence, Italy
| | - Giuseppe Indolfi
- Department of Paediatrics, Meyer Children's University Hospital, Florence, Italy
| | - Chiara Azzari
- Department of Health Sciences, University of Florence and Meyer Children's University Hospital, Florence, Italy
| |
Collapse
|
8
|
Aguilera A, Alados JC, Alonso R, Eiros JM, García F. Current position of viral load versus hepatitis C core antigen testing. Enferm Infecc Microbiol Clin 2021; 38 Suppl 1:12-18. [PMID: 32111360 DOI: 10.1016/j.eimc.2020.02.003] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Quantification of hepatitis C virus (HCV) RNA (viral load) is the most widely used marker to diagnose and confirm active HCV infection. The HCV core antigen forms part of the internal structure of the virus and, like HCV RNA, its detection also indicates viral replication and presents certain advantages over viral load testing such as its lower cost, the greater stability of the target, the possibility of working with the same primary tube as that used for HCV serology, and the rapidity of obtaining results, since there is no need to work in batches, unlike the situation with most viral load platforms. Although the core antigen has lower analytical sensitivity than HCV RNA for the detection of low viremia levels, several studies and guidelines have already shown their utility in the identification of patients with active HCV infection. This article summarises current platforms for viral load determination, including point-of-care systems, and also reviews the indications attributed to this marker by the main HCV treatment guidelines. The article also reviews the characteristics of HCV core antigen, the available platforms for its determination, its correlation with viral load determination, and the indications for this marker in the distinct guidelines.
Collapse
Affiliation(s)
- Antonio Aguilera
- Servicio de Microbiología, Complejo Hospitalario Universitario de Santiago de Compostela y Departamento de Microbiología de la Universidad de Santiago de Compostela, Santiago de Compostela, A Coruña, España
| | - Juan Carlos Alados
- Servicio de Microbiología, Hospital Universitario de Jerez, Jerez, Cádiz, España
| | - Roberto Alonso
- Servicio de Microbiología, Hospital Universitario Gregorio Marañón, Madrid, España
| | - José María Eiros
- Servicio de Microbiología, Hospital Universitario Río Hortega, Valladolid, España
| | - Federico García
- Servicio de Microbiología, Hospital Universitario San Cecilio, Granada, España; Instituto de Investigación Biosanitaria Ibs.Granada, Granada, España.
| |
Collapse
|
9
|
Prospective evaluation of hepatitis C virus antibody detection in whole blood collected on dried blood spots with the INNOTEST® HCV Ab IV enzyme immunoassay. J Clin Virol 2021; 137:104783. [PMID: 33711695 DOI: 10.1016/j.jcv.2021.104783] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/28/2020] [Revised: 02/25/2021] [Accepted: 02/28/2021] [Indexed: 12/18/2022]
Abstract
INTRODUCTION Dried blood spots (DBS) have potential to improve access to screening for antibodies to hepatitis C virus (HCV). However, although several studies on off-label use of DBS have been performed, to date no HCV antibody serology test is formally approved for use with DBS. This study evaluated the performance of the INNOTEST® HCV Ab IV enzyme immunoassay in paired DBS and plasma samples, to determine whether DBS may be added to the intended use. METHODS Adults with no history of HCV treatment were prospectively enrolled from two sites in Ukraine. DBS were prepared from fingerstick whole blood (fDBS) and venous whole blood (vDBS) samples. Undiluted and serially diluted DBS and plasma samples were tested. RESULTS Samples from 149 HCV positive and 151 HCV negative participants were included. Sensitivity and specificity of the INNOTEST® HCV Ab IV assay were both 100 % (95 % confidence intervals 95.7-100) for samples collected on fDBS or vDBS compared with plasma as the reference standard. In all undiluted samples, negative and positive percentage agreement and overall rate of agreement were 100 % between all sample types (Cohen's kappa coefficient of 1). In serially diluted samples, agreement was high (>95 %) between fDBS and vDBS, and as expected, positive percentage agreement between both DBS sample types and plasma was lower (>66 %). CONCLUSIONS Performance of the INNOTEST® HCV Ab IV assay in DBS was acceptable, thus whole blood collected on DBS may represent an alternative sample type for this assay in settings where venous blood collection is not possible.
Collapse
|
10
|
Epidemiology of hepatitis B and C virus infection in Central West Argentina. Arch Virol 2020; 165:913-922. [PMID: 32078045 DOI: 10.1007/s00705-020-04540-7] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2019] [Accepted: 12/30/2019] [Indexed: 02/07/2023]
Abstract
Little information is available regarding the prevalence of viral hepatitis in Central West Argentina. This study aims to give new information regarding HBV and HCV prevalence, genotypes, and risk factors in Central West Argentina and the suitability of dried blood spot (DBS) sampling for HBV and HCV screening. METHODS A total of 622 individuals were included; the mean age was 36.6 ± 14.3 years and 55.4% were females. HBV and HCV markers were detected using serological and molecular analysis, and risk factors were evaluated using statistical analysis. RESULTS Using serum samples, the HBsAg prevalence was 1.8%, the rate of HBV exposure (anti-HBc positivity) was 5.3%, and the rate of HBV immunity was 34.9%. HBV DNA was found in four out of 11 HBsAg+ samples, and the viruses in three of these samples were classified as genotypes A1, A2 and F2a. Multivariate analysis showed that anti-HBs positivity was associated with the level of schooling and history of HBV vaccination. The anti-HCV prevalence was 2.6%, and HCV RNA was found in 11 samples, seven of which contained viruses of genotypes 1a (n = 2), 1b (n = 3) and 2 (n = 2). The sensitivity of the DBS assay for HBsAg, anti-HBc, and anti-HCV was 100%, 66.6%, and 75%, respectively, and the specificity was above 98% for all markers when compared to serum. CONCLUSION A low rate of HBV immunity was observed, demonstrating the importance of HBV vaccination. High HCV prevalence was found, and HCV 1b was closely related to other Argentinian isolates. Finally, the performance of DBS testing in this population needs more optimization to increase its sensitivity and specificity.
Collapse
|
11
|
Ranjan J, Ponnuvel S, Fletcher GJ, Anantharam R, Radhakrishnan K, Jeyaseelan V, Abraham P. Evaluation of dried blood spots as a feasible alternative to plasma for the detection and quantification of hepatitis c virus in a tropical setting: A pilot study. Indian J Med Microbiol 2019; 37:60-66. [PMID: 31424012 DOI: 10.4103/ijmm.ijmm_19_12] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/05/2023]
Abstract
Introduction Confirmatory diagnosis of hepatitis C virus (HCV) infection (HCV RNA detection) is essential before start of the therapy. HCV RNA detection is not available in many parts of India. Shipment of plasma from distant places to referral laboratories may affect HCV RNA titres. Dried blood spots (DBS) provide an easy alternative for transporting samples to centres where HCV RNA testing is done. Aim Evaluation of DBS as a feasible alternative to plasma for HCV diagnosis. Methods In this cross-sectional study, 40 consecutive patients' blood samples were collected from patients referred from the Liver Clinic. Whole blood was spotted onto two Whatman 903TM cards. One card was incubated at ≥37°C and other at 4°C for 15 days, after drying. DBS was eluted and run in Abbott RealTime HCV assay. HCV was also quantified using the Abbott ARCHITECT HCV core antigen assay for 29 of the study patients. Results were compared with normal plasma values. Results The median log HCV RNA value (in log10IU/mL) of plasma was 5.74, with normalised DBS it was 4.92 (≥37°C) and 4.66 (4°C); difference in plasma and DBS median log values was 0.82 (≥37°C) and 1.08 (4°C) logs, respectively. Interclass correlation values were 0.943, P < 0.0001 (≥37°C) and 0.950, P < 0.0001 (4°C), showing high agreement. The median HCV core antigen value (in fmol/L) for plasma was 325.35, whereas it was 4.77 (≥37°C) and 4.64 (4°C) for DBS samples. Conclusions DBS can be used for sampling patients from distant resource-limited settings as an alternative to plasma for HCV RNA estimation. Larger studies are required to evaluate the feasibility of DBS in the Indian subcontinent, especially for HCV core antigen estimation.
Collapse
Affiliation(s)
- Jai Ranjan
- Department of Clinical Virology, Christian Medical College, Vellore, Tamil Nadu, India
| | - Suresh Ponnuvel
- Department of Clinical Virology, Christian Medical College, Vellore, Tamil Nadu, India
| | | | | | | | | | - Priya Abraham
- Department of Clinical Virology, Christian Medical College, Vellore, Tamil Nadu, India
| |
Collapse
|
12
|
Fourati S, Feld JJ, Chevaliez S, Luhmann N. Approaches for simplified HCV diagnostic algorithms. J Int AIDS Soc 2019; 21 Suppl 2:e25058. [PMID: 29633561 PMCID: PMC5978654 DOI: 10.1002/jia2.25058] [Citation(s) in RCA: 41] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2017] [Accepted: 12/24/2017] [Indexed: 12/16/2022] Open
Abstract
Introduction In the light of the advances in HCV antiviral therapy, global control of HCV infection becomes feasible but depends on the capacity of countries to identify infected people and to offer them treatment. To achieve the WHO goal which targets a diagnosis rate of 90% by 2030, simplification of screening and diagnosis will be crucial. Methods Published literature, unpublished data and expert consensus were used to determine key parameters, including point‐of‐care, rapid diagnostic testing, screening, the use of HCV core Ag and dried blood spots; starting from 2008 until November 2017. In addition, a manual search was undertaken to detect relevant papers or websites related to specific data from countries which underwent or are planning a programme of HCV elimination. Results Several strategies have been developed and evaluated these last years to simplify and facilitate access to screening and diagnosis, the development of reliable HCV core antigen tests and new nucleic acid amplification technologies for use in decentralized settings. In high prevalence settings, a one‐step screening and diagnosis strategy could simplify diagnostic algorithms provided the cost is reduced. Finally, genotyping may no longer be required in the context of availability of pangenotypic antiviral therapy. Conclusions Despite relevant advances in HCV screening and diagnosis, the overall diagnosis package is still too expensive today and efforts must be made to allow generalized implementation of reliable tests in low and middle income countries. These efforts will be key factors to foster a real public health approach to HCV elimination.
Collapse
Affiliation(s)
- Slim Fourati
- Department of Virology, Henri Mondor Hospital, National Reference Center for Viral Hepatitis B, C and delta D, INSERMU955, Créteil, France
| | - Jordan J Feld
- Toronto Centre for Liver Disease, Sandra Rotman Centre for Global Health, University of Toronto, Toronto, Canada
| | - Stéphane Chevaliez
- Department of Virology, Henri Mondor Hospital, National Reference Center for Viral Hepatitis B, C and delta D, INSERMU955, Créteil, France
| | | |
Collapse
|
13
|
Vázquez-Morón S, Ardizone Jiménez B, Jiménez-Sousa MA, Bellón JM, Ryan P, Resino S. Evaluation of the diagnostic accuracy of laboratory-based screening for hepatitis C in dried blood spot samples: A systematic review and meta-analysis. Sci Rep 2019; 9:7316. [PMID: 31086259 PMCID: PMC6514168 DOI: 10.1038/s41598-019-41139-8] [Citation(s) in RCA: 32] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Accepted: 02/27/2019] [Indexed: 12/25/2022] Open
Abstract
The dried blood spot (DBS) is increasingly used for the hepatitis C virus (HCV) screening. Our objective was to perform a meta-analysis of the methodology for HCV screening in DBS samples, particularly in the type of diagnostic assay used. We performed a meta-analysis of all eligible studies published to date (March 2018). The literature search revealed 26 studies: 21 for detection of anti-HCV antibodies and 10 for detection of HCV-RNA. Statistical analyses were performed using Meta-DiSc and STATA (MIDAS module). For detection of HCV antibodies, pooled diagnostic accuracy measures were as follows: sensitivity 96.1%, specificity 99.2%, positive likelihood ratio (PLR) 105, negative likelihood ratio (NLR) 0.04, diagnostic odds ratio (DOR) 2692.9, and summary receiver operating characteristic (SROC) 0.997 ± 0.001. For detection of HCV-RNA, the pooled diagnostic accuracy measures were as follows: sensitivity 97.8%, specificity 99.2%, PLR 44.8, NLR 0.04, DOR 1966.9, and SROC 0.996 ± 0.013. Similar values of pooled diagnostic accuracy measures were found according to the type of anti-HCV antibody detection assay (enzyme-linked immunosorbent assay, rapid diagnostic test, and chemiluminescence assays) and HCV-RNA detection assay (real-time polymerase chain reaction and transcription-mediated amplification). The analysis of external validity showed a high negative predicted value (NPV) for both approaches, but a low positive predicted value (PPV) when prevalence was < 10%, particularly in HCV-RNA tests. Finally, this meta-analysis is subject to limitations, especially publication bias and significant heterogeneity between studies. In conclusion, HCV screening in DBS samples has an outstanding diagnostic performance, with no relevant differences between the techniques used. However, external validity may be limited when the HCV prevalence is low.
Collapse
Affiliation(s)
- Sonia Vázquez-Morón
- Unidad de Infección Viral e Inmunidad. Centro Nacional de Microbiología - Instituto de Salud Carlos III, Majadahonda, Spain
| | - Beatriz Ardizone Jiménez
- Unidad de Infección Viral e Inmunidad. Centro Nacional de Microbiología - Instituto de Salud Carlos III, Majadahonda, Spain
| | - María A Jiménez-Sousa
- Unidad de Infección Viral e Inmunidad. Centro Nacional de Microbiología - Instituto de Salud Carlos III, Majadahonda, Spain
| | - José M Bellón
- Hospital General Universitario Gregorio Marañón, Madrid, Spain.,Instituto de Investigación Sanitaria Gregorio Marañón (IiSGM), Madrid, Spain
| | - Pablo Ryan
- Hospital Universitario Infanta Leonor (HUIL). Vallecas, Madrid, Spain
| | - Salvador Resino
- Unidad de Infección Viral e Inmunidad. Centro Nacional de Microbiología - Instituto de Salud Carlos III, Majadahonda, Spain.
| |
Collapse
|
14
|
Mahajan S, Choudhary MC, Kumar G, Gupta E. Evaluation of dried blood spot as an alternative sample collection method for hepatitis C virus RNA quantitation and genotyping using a commercial system. Virusdisease 2018; 29:141-146. [PMID: 29911146 PMCID: PMC6003055 DOI: 10.1007/s13337-018-0441-9] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2017] [Accepted: 02/26/2018] [Indexed: 01/05/2023] Open
Abstract
Dried blood spot (DBS) is a minimally invasive sampling method suitable for sample collection, storage and transportation in resource limited areas. Aim of this study was to compare the diagnostic utility of DBS with plasma sample for HCV RNA quantitation and genotyping using commercial systems. Plasma and DBS card spotted samples were collected from 95 HCV seropositive patients. Both types of samples were subjected to HCV RNA by real-time PCR (Abbott m2000rt, USA). Genotyping was performed using Abbott HCV genotype II kit (Abbott diagnostics, USA) in samples with viral load > 3 log10 IU/ml. In both plasma and DBS, 14 (14.7%) samples were negative and 81 (85.3%) were positive for HCV RNA. Median viral load in plasma (3.78; range 0-7.43) log10 IU/ml was comparable to DBS (3.93; range 0-7.24) log10 IU/ml. DBS demonstrated sensitivity and specificity of 97.5 and 85.7% respectively, with positive predictive value (PPV) of 97.5% and negative predictive value (NPV) of 85.7%. DBS showed good correlation (r2 = 0.866) and agreement (93.5%) with plasma. Genotyping in 20 patients showed 100% concordance between DBS and plasma samples. DBS showed good sensitivity and specificity as a sampling method for HCV RNA quantitation and genotyping.
Collapse
Affiliation(s)
- Supriya Mahajan
- Department of Clinical Virology, Institute of Liver and Biliary Sciences, D – 1, Vasant Kunj, New Delhi, 110070 India
| | - Manish Chandra Choudhary
- Department of Clinical Virology, Institute of Liver and Biliary Sciences, D – 1, Vasant Kunj, New Delhi, 110070 India
| | - Guresh Kumar
- Department of Clinical Research, Institute of Liver and Biliary Sciences, New Delhi, India
| | - Ekta Gupta
- Department of Clinical Virology, Institute of Liver and Biliary Sciences, D – 1, Vasant Kunj, New Delhi, 110070 India
| |
Collapse
|
15
|
Saludes V, Folch C, Morales-Carmona A, Ferrer L, Fernàndez-López L, Muñoz R, Jiménez M, Loureiro E, Fernández-Dávila P, Bascuñana E, Casabona J, Martró E. Community-based screening of hepatitis C with a one-step RNA detection algorithm from dried-blood spots: Analysis of key populations in Barcelona, Spain. J Viral Hepat 2018; 25:236-244. [PMID: 29053912 DOI: 10.1111/jvh.12809] [Citation(s) in RCA: 25] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/04/2017] [Accepted: 08/15/2017] [Indexed: 12/30/2022]
Abstract
Alternative strategies are required to enhance the diagnosis of silent hepatitis C virus (HCV) infections in key populations at risk. Among them, HCV prevalence and bio-behavioural data are scarce for HIV-negative men who have sex with men (MSM) and men and trans-women sex workers. We sought to describe and assess the potential benefits of a community-based one-step HCV screening and confirmatory strategy for these populations in Barcelona. The screening strategy based on a real-time RT-PCR assay for HCV-RNA detection in dried-blood spots (DBS) was validated and implemented in addition to an antibody point-of-care test in a community centre. HCV prevalence was assessed, and bio-behavioural data were collected. The molecular assay was precise, reproducible, sensitive and specific. Four HIV-negative MSM reported being currently infected (0.75% HCV self-reported prevalence). Implementation of DBS testing was easy, and acceptability was >95%, but no silent HCV case was diagnosed (N = 580). High-risk sexual practices and drug use for sex were reported frequently. HIV prevalence was 4.7% in MSM and 10% in sex workers. Self-reported prevalence of other STIs ranged from 11.3% to 36.2%. In conclusion, HCV-RNA testing in DBS showed a good performance, but the assessed one-step strategy does not seem beneficial in this setting. Although no silent HCV infections were detected, the observed high-risk behaviours and prevalence of other STIs suggest that HCV spread should be periodically monitored among these populations in Barcelona by means of behavioural surveillance, rapid antibody testing and molecular confirmation in DBS.
Collapse
Affiliation(s)
- V Saludes
- Microbiology Service, Germans Trias i Pujol University Hospital, Germans Trias i Pujol Health Sciences Research Institute (IGTP), Badalona, Spain.,Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain
| | - C Folch
- Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain.,Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain
| | | | - L Ferrer
- Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain.,Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain
| | - L Fernàndez-López
- Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain.,Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain
| | - R Muñoz
- Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain
| | - M Jiménez
- Microbiology Service, Germans Trias i Pujol University Hospital, Germans Trias i Pujol Health Sciences Research Institute (IGTP), Badalona, Spain
| | - E Loureiro
- Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain.,Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain
| | - P Fernández-Dávila
- Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain.,Research Department, Stop Sida, Barcelona, Spain
| | - E Bascuñana
- Microbiology Service, Germans Trias i Pujol University Hospital, Germans Trias i Pujol Health Sciences Research Institute (IGTP), Badalona, Spain
| | - J Casabona
- Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain.,Centre d'Estudis Epidemiològics sobre les Infeccions de Transmissió Sexual i Sida de Catalunya (CEEISCAT), Departament de Salut, Generalitat de Catalunya, Badalona, Spain
| | - E Martró
- Microbiology Service, Germans Trias i Pujol University Hospital, Germans Trias i Pujol Health Sciences Research Institute (IGTP), Badalona, Spain.,Centro de Investigación Biomédica en Red en Epidemiología y Salud Pública (CIBERESP), Instituto de Salud Carlos III, Madrid, Spain
| |
Collapse
|
16
|
Vázquez-Morón S, Ryan P, Ardizone-Jiménez B, Martín D, Troya J, Cuevas G, Valencia J, Jimenez-Sousa MA, Avellón A, Resino S. Evaluation of dried blood spot samples for screening of hepatitis C and human immunodeficiency virus in a real-world setting. Sci Rep 2018; 8:1858. [PMID: 29382904 PMCID: PMC5789840 DOI: 10.1038/s41598-018-20312-5] [Citation(s) in RCA: 30] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2017] [Accepted: 01/15/2018] [Indexed: 01/05/2023] Open
Abstract
Both hepatitis C virus (HCV) infection and human immunodeficiency virus (HIV) infection are underdiagnosed, particularly in low-income countries and in difficult-to-access populations. Our aim was to develop and evaluate a methodology for the detection of HCV and HIV infection based on capillary dry blood spot (DBS) samples taken under real-world conditions. We carried out a cross-sectional study of 139 individuals (31 healthy controls, 68 HCV-monoinfected patients, and 40 HCV/HIV-coinfected patients). ELISA was used for anti-HCV and anti-HIV antibody detection; and SYBR Green RT-PCR was used for HCV-RNA detection. The HIV serological analysis revealed 100% sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV). The HCV serological analysis revealed a sensitivity of 92.6%, specificity of 100%, PPV of 100%, and NPV of 79.5%. Finally, the HCV-RNA detection test revealed a detection limit of 5 copies/µl with an efficiency of 100% and sensitivity of 99.1%, specificity of 100%, PPV of 100%, and NPV of 96.9%. In conclusion, our methodology was able to detect both HCV infection and HIV infection from the same DBS sample with good diagnostic performance. Screening for HCV and HIV using DBS might be a key strategy in the implementation of national programs for the control of both infections.
Collapse
Affiliation(s)
- Sonia Vázquez-Morón
- Laboratorio de Referencia e Investigación en Hepatitis Víricas, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain.
| | - Pablo Ryan
- Hospital Universitario Infanta Leonor (HUIL), Vallecas, Madrid, Spain
| | - Beatriz Ardizone-Jiménez
- Laboratorio de Referencia e Investigación en Hepatitis Víricas, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain
| | | | - Jesus Troya
- Hospital Universitario Infanta Leonor (HUIL), Vallecas, Madrid, Spain
| | - Guillermo Cuevas
- Hospital Universitario Infanta Leonor (HUIL), Vallecas, Madrid, Spain
| | | | - María A Jimenez-Sousa
- Laboratorio de Referencia e Investigación en Hepatitis Víricas, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain
| | - Ana Avellón
- Laboratorio de Referencia e Investigación en Hepatitis Víricas, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain
| | - Salvador Resino
- Laboratorio de Referencia e Investigación en Hepatitis Víricas, Centro Nacional de Microbiología, Instituto de Salud Carlos III, Majadahonda, Madrid, Spain
| |
Collapse
|
17
|
Lange B, Cohn J, Roberts T, Camp J, Chauffour J, Gummadi N, Ishizaki A, Nagarathnam A, Tuaillon E, van de Perre P, Pichler C, Easterbrook P, Denkinger CM. Diagnostic accuracy of serological diagnosis of hepatitis C and B using dried blood spot samples (DBS): two systematic reviews and meta-analyses. BMC Infect Dis 2017; 17:700. [PMID: 29143672 PMCID: PMC5688450 DOI: 10.1186/s12879-017-2777-y] [Citation(s) in RCA: 67] [Impact Index Per Article: 8.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022] Open
Abstract
BACKGROUND Dried blood spots (DBS) are a convenient tool to enable diagnostic testing for viral diseases due to transport, handling and logistical advantages over conventional venous blood sampling. A better understanding of the performance of serological testing for hepatitis C (HCV) and hepatitis B virus (HBV) from DBS is important to enable more widespread use of this sampling approach in resource limited settings, and to inform the 2017 World Health Organization (WHO) guidance on testing for HBV/HCV. METHODS We conducted two systematic reviews and meta-analyses on the diagnostic accuracy of HCV antibody (HCV-Ab) and HBV surface antigen (HBsAg) from DBS samples compared to venous blood samples. MEDLINE, EMBASE, Global Health and Cochrane library were searched for studies that assessed diagnostic accuracy with DBS and agreement between DBS and venous sampling. Heterogeneity of results was assessed and where possible a pooled analysis of sensitivity and specificity was performed using a bivariate analysis with maximum likelihood estimate and 95% confidence intervals (95%CI). We conducted a narrative review on the impact of varying storage conditions or limits of detection in subsets of samples. The QUADAS-2 tool was used to assess risk of bias. RESULTS For the diagnostic accuracy of HBsAg from DBS compared to venous blood, 19 studies were included in a quantitative meta-analysis, and 23 in a narrative review. Pooled sensitivity and specificity were 98% (95%CI:95%-99%) and 100% (95%CI:99-100%), respectively. For the diagnostic accuracy of HCV-Ab from DBS, 19 studies were included in a pooled quantitative meta-analysis, and 23 studies were included in a narrative review. Pooled estimates of sensitivity and specificity were 98% (CI95%:95-99) and 99% (CI95%:98-100), respectively. Overall quality of studies and heterogeneity were rated as moderate in both systematic reviews. CONCLUSION HCV-Ab and HBsAg testing using DBS compared to venous blood sampling was associated with excellent diagnostic accuracy. However, generalizability is limited as no uniform protocol was applied and most studies did not use fresh samples. Future studies on diagnostic accuracy should include an assessment of impact of environmental conditions common in low resource field settings. Manufacturers also need to formally validate their assays for DBS for use with their commercial assays.
Collapse
Affiliation(s)
- Berit Lange
- Division of Infectious Diseases, Department of Medicine II, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, Freiburg, Germany. .,Centre for Chronic Immunodeficiency, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, Freiburg, Germany.
| | - Jennifer Cohn
- Department of Infectious Diseases, University of Pennsylvania, PA, Philadelphia, USA
| | | | - Johannes Camp
- Division of Infectious Diseases, Department of Medicine II, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Germany, Freiburg, Germany
| | | | - Nina Gummadi
- School of Medicine, Boston University, Boston, USA
| | - Azumi Ishizaki
- Global Hepatitis Programme, HIV Department, World Health Organization, Geneva, Switzerland
| | | | - Edouard Tuaillon
- Pathogenesis and Control of Chronic Infections UMR 1058 INSERM/Université Montpellier/Etablissement Français du Sang, INSERM, 34394, Montpellier Cedex 5, France.,Centre Hospitalier Universitaire (CHU) de Montpellier, Département de bactériologie-virologie, Montpellier, France
| | - Philippe van de Perre
- Pathogenesis and Control of Chronic Infections UMR 1058 INSERM/Université Montpellier/Etablissement Français du Sang, INSERM, 34394, Montpellier Cedex 5, France.,Centre Hospitalier Universitaire (CHU) de Montpellier, Département de bactériologie-virologie, Montpellier, France
| | - Christine Pichler
- Department of Medicine II, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Philippa Easterbrook
- Global Hepatitis Programme, HIV Department, World Health Organization, Geneva, Switzerland
| | | |
Collapse
|
18
|
Lange B, Roberts T, Cohn J, Greenman J, Camp J, Ishizaki A, Messac L, Tuaillon E, van de Perre P, Pichler C, Denkinger CM, Easterbrook P. Diagnostic accuracy of detection and quantification of HBV-DNA and HCV-RNA using dried blood spot (DBS) samples - a systematic review and meta-analysis. BMC Infect Dis 2017; 17:693. [PMID: 29143616 PMCID: PMC5688458 DOI: 10.1186/s12879-017-2776-z] [Citation(s) in RCA: 68] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
BACKGROUND The detection and quantification of hepatitis B (HBV) DNA and hepatitis C (HCV) RNA in whole blood collected on dried blood spots (DBS) may facilitate access to diagnosis and treatment of HBV and HCV infection in resource-poor settings. We evaluated the diagnostic performance of DBS compared to venous blood samples for detection and quantification of HBV-DNA and HCV-RNA in two systematic reviews and meta-analyses on the diagnostic accuracy of HBV DNA and HCV RNA from DBS compared to venous blood samples. METHODS We searched MEDLINE, Embase, Global Health, Web of Science, LILAC and Cochrane library for studies that assessed diagnostic accuracy with DBS. Heterogeneity was assessed and where appropriate pooled estimates of sensitivity and specificity were generated using bivariate analyses with maximum likelihood estimates and 95% confidence intervals. We also conducted a narrative review on the impact of varying storage conditions or different cut-offs for detection from studies that undertook this in a subset of samples. The QUADAS-2 tool was used to assess risk of bias. RESULTS In the quantitative synthesis for diagnostic accuracy of HBV-DNA using DBS, 521 citations were identified, and 12 studies met the inclusion criteria. Overall quality of studies was rated as low. The pooled estimate of sensitivity and specificity for HBV-DNA was 95% (95% CI: 83-99) and 99% (95% CI: 53-100), respectively. In the two studies that reported on cut-offs and limit of detection (LoD) - one reported a sensitivity of 98% for a cut-off of ≥2000 IU/ml and another reported a LoD of 914 IU/ml using a commercial assay. Varying storage conditions for individual samples did not result in a significant variation of results. In the synthesis for diagnostic accuracy of HCV-RNA using DBS, 15 studies met the inclusion criteria, and this included six additional studies to a previously published review. The pooled sensitivity and specificity was 98% (95% CI:95-99) and 98% (95% CI:95-99.0), respectively. Varying storage conditions resulted in a decrease in accuracy for quantification but not for reported positivity. CONCLUSIONS These findings show a high level of diagnostic performance for the use of DBS for HBV-DNA and HCV-RNA detection. However, this was based on a limited number and quality of studies. There is a need for development of standardized protocols by manufacturers on the use of DBS with their assays, as well as for larger studies on use of DBS conducted in different settings and with varying storage conditions.
Collapse
Affiliation(s)
- Berit Lange
- Division of Infectious Diseases, Department of Medicine II, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
- Centre for Chronic Immunodeficiency, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
| | | | - Jennifer Cohn
- Department of Infectious Diseases, University of Pennsylvania, Philadelphia, PA, USA
| | - Jamie Greenman
- Department of Infectious Diseases, University of Pennsylvania, Philadelphia, PA, USA
| | - Johannes Camp
- Division of Infectious Diseases, Department of Medicine II, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | - Azumi Ishizaki
- Global Hepatitis Programme, HIV Department, World Health Organization, Geneva, Switzerland
| | - Luke Messac
- Department of Infectious Diseases, University of Pennsylvania, Philadelphia, PA, USA
| | - Edouard Tuaillon
- Pathogenesis and Control of Chronic Infections UMR 1058, INSERM/Université Montpellier/Etablissement Français du Sang, INSERM, 34394, Cedex 5, Montpellier, France
- Centre Hospitalier Universitaire (CHU) de Montpellier, département de bactériologie-virologie, Montpellier, France
| | - Philippe van de Perre
- Pathogenesis and Control of Chronic Infections UMR 1058, INSERM/Université Montpellier/Etablissement Français du Sang, INSERM, 34394, Cedex 5, Montpellier, France
- Centre Hospitalier Universitaire (CHU) de Montpellier, département de bactériologie-virologie, Montpellier, France
| | - Christine Pichler
- Division of Infectious Diseases, Department of Medicine II, Medical Center - University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany
| | | | - Philippa Easterbrook
- Global Hepatitis Programme, HIV Department, World Health Organization, Geneva, Switzerland
| |
Collapse
|
19
|
Hepatitis C Virus (HCV) RNA screening and sequencing using dry plasma spots. J Clin Virol 2017; 97:18-21. [PMID: 29080433 DOI: 10.1016/j.jcv.2017.10.012] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2017] [Revised: 10/01/2017] [Accepted: 10/20/2017] [Indexed: 12/17/2022]
Abstract
BACKGROUND HCV RNA screening of large sample repositories provides data on HCV epidemic patterns that may help guide control policies. In resource-limited settings, shipment of frozen samples to molecular laboratory facilities and testing of individual samples may be prohibitively expensive. OBJECTIVE Our aim was to detect and sequence HCV RNA in a large HIV-positive cohort from Kumasi, Ghana, using pooled and individual dried plasma spots (DPS) produced from samples stored at -80°C. STUDY DESIGN In the validation phase, replicate DPS were prepared with six dilutions (500-10,000 IU/ml) of the 4th International Standard for HCV and tested in three independent experiments. In the testing phase, DPS prepared with plasma samples from 875 HIV-positive subjects were pooled for screening, followed by testing of individual DPS of positive pools. Input from individual DPS was two 6mm punches; pools comprised two punches from each of five DPS. Genotypes were determined by Sanger sequencing of HCV core and NS5B. RESULTS With the dilution series, sensitivity of HCV RNA detection was ≥2500 IU/ml. Replicate DPS gave intra-assay and inter-assay coefficients of variation ≤1.4%. With the stored samples, HCV RNA was detected in 5/175 DPS pools and in one DPS from each positive pool, yielding a HCV RNA prevalence of 5/875 (0.57%; 95% confidence interval 0.07-1.07%). The five samples were sequenced as HCV genotypes 2l and 2r. DISCUSSION DPS allowed reproducible HCV RNA detection, and pooling effectively contained the cost and labour of screening a previously untested, low-prevalence cohort. DPS were also suitable for HCV sequencing.
Collapse
|
20
|
Muzembo BA, Mbendi NC, Nakayama SF. Systematic review with meta-analysis: performance of dried blood spots for hepatitis C antibodies detection. Public Health 2017; 153:128-136. [PMID: 29035801 DOI: 10.1016/j.puhe.2017.08.008] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/10/2017] [Revised: 07/10/2017] [Accepted: 08/21/2017] [Indexed: 12/30/2022]
Abstract
OBJECTIVES Dried blood spots (DBS) specimens can be used for hepatitis C virus (HCV) infection screening in cases where serum specimens are difficult to obtain. However, uncertainties surround the sensitivity and specificity of DBS for HCV antibodies (anti-HCV) serology testing. We aimed to evaluate the accuracy of DBS use to screen for HCV infection. STUDY DESIGN We carried out a systematic review and meta-analysis. METHODS Medline and EMBASE databases were searched for articles published between 1989 and November 2016. We included studies comparing DBS to plasma/serum specimens to detect anti-HCV in adults. Two authors extracted data and assessed the quality of the studies using an adapted standards for reporting diagnostic accuracy studies (STARD) and independently checked the data for accuracy. Meta-analysis was computed with the bivariate and the hierarchical summary receiver-operating characteristic models. RESULTS Twelve studies (3307 specimens) were analyzed, where 11 of them evaluated the anti-HCV using enzyme immunoassays (EIAs), and the remaining one used rapid diagnostic tests. The studies were mostly case-controls (83.3%) and from developed countries (66.7%). The overall pooled sensitivity (95% confidence interval; CI) and specificity (95% CI) of DBS to detect anti-HCV was 98.1% (96.1-99.1%) and 99.7% (98.9-99.9%), respectively. In studies using EIAs, the pooled sensitivity and specificity were 97.3% (94.3-98.8%) and 99.6% (98.5-99.9%), respectively. Considering only studies using EIAs, sensitivity analysis excluding one study carried out in people who inject drugs showed the pooled sensitivity of 97.8% (96.2-98.8%) and specificity of 99.5% (98.5-99.9%). CONCLUSIONS In testing for anti-HCV by means of EIAs, the efficacy of DBS is found to be similar or slightly lower than that of serum specimens. However, the risk of finding negative and positive results that are both false when using DBS remains present. Therefore, further work including optimal storage and processing methodologies are recommended. This is to help establish consensus guidelines for use of DBS specimens for anti-HCV screening.
Collapse
Affiliation(s)
- B A Muzembo
- Center for Health and Environmental Risk Research, National Institute for Environmental Studies, Tsukuba, Japan.
| | - N C Mbendi
- Gastroenterology Department, Kinshasa University, Kinshasa, DR Congo
| | - S F Nakayama
- Center for Health and Environmental Risk Research, National Institute for Environmental Studies, Tsukuba, Japan
| |
Collapse
|