1
|
Yang W, Gong Y, Li W. A Review: Electrode and Packaging Materials for Neurophysiology Recording Implants. Front Bioeng Biotechnol 2020; 8:622923. [PMID: 33585422 PMCID: PMC7873964 DOI: 10.3389/fbioe.2020.622923] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/29/2020] [Accepted: 12/10/2020] [Indexed: 01/28/2023] Open
Abstract
To date, a wide variety of neural tissue implants have been developed for neurophysiology recording from living tissues. An ideal neural implant should minimize the damage to the tissue and perform reliably and accurately for long periods of time. Therefore, the materials utilized to fabricate the neural recording implants become a critical factor. The materials of these devices could be classified into two broad categories: electrode materials as well as packaging and substrate materials. In this review, inorganic (metals and semiconductors), organic (conducting polymers), and carbon-based (graphene and carbon nanostructures) electrode materials are reviewed individually in terms of various neural recording devices that are reported in recent years. Properties of these materials, including electrical properties, mechanical properties, stability, biodegradability/bioresorbability, biocompatibility, and optical properties, and their critical importance to neural recording quality and device capabilities, are discussed. For the packaging and substrate materials, different material properties are desired for the chronic implantation of devices in the complex environment of the body, such as biocompatibility and moisture and gas hermeticity. This review summarizes common solid and soft packaging materials used in a variety of neural interface electrode designs, as well as their packaging performances. Besides, several biopolymers typically applied over the electrode package to reinforce the mechanical rigidity of devices during insertion, or to reduce the immune response and inflammation at the device-tissue interfaces are highlighted. Finally, a benchmark analysis of the discussed materials and an outlook of the future research trends are concluded.
Collapse
Affiliation(s)
- Weiyang Yang
- Microtechnology Lab, Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, United States
| | - Yan Gong
- Microtechnology Lab, Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, United States
| | - Wen Li
- Microtechnology Lab, Department of Electrical and Computer Engineering, Michigan State University, East Lansing, MI, United States
| |
Collapse
|
2
|
Pardo-Figuerez M, Martin NRW, Player DJ, Roach P, Christie SDR, Capel AJ, Lewis MP. Controlled Arrangement of Neuronal Cells on Surfaces Functionalized with Micropatterned Polymer Brushes. ACS OMEGA 2018; 3:12383-12391. [PMID: 30411006 PMCID: PMC6217525 DOI: 10.1021/acsomega.8b01698] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/18/2018] [Accepted: 09/17/2018] [Indexed: 05/03/2023]
Abstract
Conventional in vitro cultures are useful to represent simplistic neuronal behavior; however, the lack of organization results in random neurite spreading. To overcome this problem, control over the directionality of SH-SY5Y cells was attained, utilizing photolithography to pattern the cell-repulsive anionic brush poly(potassium 3-sulfopropyl methacrylate) (PKSPMA) into tracks of 20, 40, 80, and 100 μm width. These data validate the use of PKSPMA brush coatings for a long-term culture of the SH-SY5Y cells, as well as providing a methodology by which the precise deposition of PKSPMA can be utilized to achieve a targeted control over the SH-SY5Y cells. Specifically, the PKSPMA brush patterns prevented cell attachment, allowing the SH-SY5Y cells to grow only on noncoated glass (gaps of 20, 50, 75, and 100 μm width) at different cell densities (5000, 10 000, and 15 000 cells/cm2). This research demonstrates the importance of achieving cell directionality in vitro, while these simplistic models could provide new platforms to study complex neuron-neuron interactions.
Collapse
Affiliation(s)
- Maria Pardo-Figuerez
- National
Centre for Sport and Exercise Medicine (NCSEM), School of
Sport, Exercise and Health Sciences, and Department of Chemistry, School
of Science, Loughborough University, Loughborough LE11 3TU, U.K.
| | - Neil R. W. Martin
- National
Centre for Sport and Exercise Medicine (NCSEM), School of
Sport, Exercise and Health Sciences, and Department of Chemistry, School
of Science, Loughborough University, Loughborough LE11 3TU, U.K.
| | - Darren J. Player
- National
Centre for Sport and Exercise Medicine (NCSEM), School of
Sport, Exercise and Health Sciences, and Department of Chemistry, School
of Science, Loughborough University, Loughborough LE11 3TU, U.K.
- Institute
of Orthopaedics and Musculoskeletal Science, University College London, Stanmore HA7 4LP, U.K.
| | - Paul Roach
- National
Centre for Sport and Exercise Medicine (NCSEM), School of
Sport, Exercise and Health Sciences, and Department of Chemistry, School
of Science, Loughborough University, Loughborough LE11 3TU, U.K.
| | - Steven D. R. Christie
- National
Centre for Sport and Exercise Medicine (NCSEM), School of
Sport, Exercise and Health Sciences, and Department of Chemistry, School
of Science, Loughborough University, Loughborough LE11 3TU, U.K.
| | - Andrew J. Capel
- National
Centre for Sport and Exercise Medicine (NCSEM), School of
Sport, Exercise and Health Sciences, and Department of Chemistry, School
of Science, Loughborough University, Loughborough LE11 3TU, U.K.
| | - Mark P. Lewis
- National
Centre for Sport and Exercise Medicine (NCSEM), School of
Sport, Exercise and Health Sciences, and Department of Chemistry, School
of Science, Loughborough University, Loughborough LE11 3TU, U.K.
| |
Collapse
|
3
|
Selective PEGylation of Parylene-C/SiO 2 Substrates for Improved Astrocyte Cell Patterning. Sci Rep 2018; 8:2754. [PMID: 29426929 PMCID: PMC5807449 DOI: 10.1038/s41598-018-21135-0] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Accepted: 01/17/2018] [Indexed: 11/23/2022] Open
Abstract
Controlling the spatial distribution of glia and neurons in in vitro culture offers the opportunity to study how cellular interactions contribute to large scale network behaviour. A recently developed approach to cell-patterning uses differential adsorption of animal-serum protein on parylene-C and SiO2 surfaces to enable patterning of neurons and glia. Serum, however, is typically poorly defined and generates reproducibility challenges. Alternative activation methods are highly desirable to enable patterning without relying on animal serum. We take advantage of the innate contrasting surface chemistries of parylene-C and SiO2 to enable selective bonding of polyethylene glycol SiO2 surfaces, i.e. PEGylation, rendering them almost completely repulsive to cell adhesion. As the reagents used in the PEGylation protocol are chemically defined, the reproducibility and batch-to-batch variability complications associated with the used of animal serum are avoided. We report that PEGylated parylene-C/SiO2 substrates achieve a contrast in astrocyte density of 65:1 whereas the standard serum-immersion protocol results in a contrast of 5.6:1. Furthermore, single-cell isolation was significantly improved on PEGylated substrates when astrocytes were grown on close-proximity parylene-C nodes, whereas isolation was limited on serum-activated substrates due tolerance for cell adhesion on serum-adsorbed SiO2 surfaces.
Collapse
|
4
|
Zhu G, Du L, Jin L, Offenhäusser A. Effects of Morphology Constraint on Electrophysiological Properties of Cortical Neurons. Sci Rep 2016; 6:23086. [PMID: 27052791 PMCID: PMC4823731 DOI: 10.1038/srep23086] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2015] [Accepted: 02/26/2016] [Indexed: 11/08/2022] Open
Abstract
There is growing interest in engineering nerve cells in vitro to control architecture and connectivity of cultured neuronal networks or to build neuronal networks with predictable computational function. Pattern technologies, such as micro-contact printing, have been developed to design ordered neuronal networks. However, electrophysiological characteristics of the single patterned neuron haven't been reported. Here, micro-contact printing, using polyolefine polymer (POP) stamps with high resolution, was employed to grow cortical neurons in a designed structure. The results demonstrated that the morphology of patterned neurons was well constrained, and the number of dendrites was decreased to be about 2. Our electrophysiological results showed that alterations of dendritic morphology affected firing patterns of neurons and neural excitability. When stimulated by current, though both patterned and un-patterned neurons presented regular spiking, the dynamics and strength of the response were different. The un-patterned neurons exhibited a monotonically increasing firing frequency in response to injected current, while the patterned neurons first exhibited frequency increase and then a slow decrease. Our findings indicate that the decrease in dendritic complexity of cortical neurons will influence their electrophysiological characteristics and alter their information processing activity, which could be considered when designing neuronal circuitries.
Collapse
Affiliation(s)
- Geng Zhu
- Institute of Complex Systems, Bioelectronics (PGI-8/ICS-8), Forschungszentrum Jülich, JARA – FIT, Jülich D-52425, Germany
- Bio-X Institutes, Key Laboratory for the Genetics of Development and Neuropsychiatric Disorders (Ministry of Education), and Shanghai Key Laboratory of Psychotic Disorders, Brain Science and Technology Research Center, Shanghai Jiao Tong University, 800 Dongchuan Road, Shanghai 200240, China
| | - Liping Du
- Institute of Complex Systems, Bioelectronics (PGI-8/ICS-8), Forschungszentrum Jülich, JARA – FIT, Jülich D-52425, Germany
- Department of Biomedical Engineering, Zhejiang University, Hangzhou 310027, China
| | - Lei Jin
- Institute of Complex Systems, Bioelectronics (PGI-8/ICS-8), Forschungszentrum Jülich, JARA – FIT, Jülich D-52425, Germany
| | - Andreas Offenhäusser
- Institute of Complex Systems, Bioelectronics (PGI-8/ICS-8), Forschungszentrum Jülich, JARA – FIT, Jülich D-52425, Germany
| |
Collapse
|
5
|
Integrated Circuit-Based Biofabrication with Common Biomaterials for Probing Cellular Biomechanics. Trends Biotechnol 2016; 34:171-186. [DOI: 10.1016/j.tibtech.2015.11.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2015] [Revised: 11/03/2015] [Accepted: 11/18/2015] [Indexed: 01/10/2023]
|
6
|
Du X, Wu L, Cheng J, Huang S, Cai Q, Jin Q, Zhao J. Graphene microelectrode arrays for neural activity detection. J Biol Phys 2015; 41:339-47. [PMID: 25712492 DOI: 10.1007/s10867-015-9382-3] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2014] [Accepted: 01/22/2015] [Indexed: 10/23/2022] Open
Abstract
We demonstrate a method to fabricate graphene microelectrode arrays (MEAs) using a simple and inexpensive method to solve the problem of opaque electrode positions in traditional MEAs, while keeping good biocompatibility. To study the interface differences between graphene-electrolyte and gold-electrolyte, graphene and gold electrodes with a large area were fabricated. According to the simulation results of electrochemical impedances, the gold-electrolyte interface can be described as a classical double-layer structure, while the graphene-electrolyte interface can be explained by a modified double-layer theory. Furthermore, using graphene MEAs, we detected the neural activities of neurons dissociated from Wistar rats (embryonic day 18). The signal-to-noise ratio of the detected signal was 10.31 ± 1.2, which is comparable to those of MEAs made with other materials. The long-term stability of the MEAs is demonstrated by comparing differences in Bode diagrams taken before and after cell culturing.
Collapse
Affiliation(s)
- Xiaowei Du
- State Key Laboratory of Transducer Technology, Shanghai Institute of Microsystem and Information Technology, Chinese Academy of Sciences, Shanghai, 200050, China
| | | | | | | | | | | | | |
Collapse
|
7
|
Schröter A, Franzka S, Hartmann N. Photothermal laser fabrication of micro- and nanostructured chemical templates for directed protein immobilization. LANGMUIR : THE ACS JOURNAL OF SURFACES AND COLLOIDS 2014; 30:14841-14848. [PMID: 25397891 DOI: 10.1021/la503814n] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Photothermal patterning of poly(ethylene glycol) terminated organic monolayers on surface-oxidized silicon substrates is carried out using a microfocused beam of a CW laser operated at a wavelength of 532 nm. Trichlorosilane and trimethoxysilane precursors are used for coating. Monolayers from trimethoxysilane precursors show negligible unspecific protein adsorption in the background, i.e., provide platforms of superior protein repellency. Laser patterning results in decomposition of the monolayers and yields chemical templates for directed immobilization of proteins at predefined positions. Characterization is carried out via complementary analytical methods including fluorescence microscopy, atomic force microscopy, and scanning electron microscopy. Appropriate labeling techniques (fluorescent markers and gold clusters) and substrates (native and thermally oxidized silicon substrates) are chosen in order to facilitate identification of protein adsorption and ensure high sensitivity and selectivity. Variation of the laser parameters at a 1/e(2) spot diameter of 2.8 μm allows for fabrication of protein binding domains with diameters on the micrometer and nanometer length scale. Minimum domain sizes are about 300 nm. In addition to unspecific protein adsorption on as-patterned monolayers, biotin-streptavidin coupling chemistry is exploited for specific protein binding. This approach represents a novel facile laser-based means for fabrication of protein micro- and nanopatterns. The routine is readily applicable to femtosecond laser processing of glass substrates for the fabrication of transparent templates.
Collapse
Affiliation(s)
- Anja Schröter
- Fakultät für Chemie, Universität Duisburg-Essen , 45117 Essen, Germany
| | | | | |
Collapse
|
8
|
Santoro F, Panaitov G, Offenhäusser A. Defined patterns of neuronal networks on 3D thiol-functionalized microstructures. NANO LETTERS 2014; 14:6906-9. [PMID: 25415470 DOI: 10.1021/nl502922b] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
It is very challenging to study the behavior of neuronal cells in a network due to the multiple connections between the cells. Our idea is then to simplify such a network with a configuration where cells can have just a fixed number of connections in order to create a well-defined and ordered network. Here, we report about guiding primary cortical neurons with three-dimensional gold microspines selectively functionalized with an amino-terminated molecule.
Collapse
Affiliation(s)
- Francesca Santoro
- Institute of Bioelectronics ICS-8/PGI-8, Forschungszentrum Jülich , 52425 Jülich, Germany
| | | | | |
Collapse
|
9
|
Kim R, Joo S, Jung H, Hong N, Nam Y. Recent trends in microelectrode array technology for in vitro neural interface platform. Biomed Eng Lett 2014. [DOI: 10.1007/s13534-014-0130-6] [Citation(s) in RCA: 73] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
|
10
|
Santoro F, Schnitker J, Panaitov G, Offenhäusser A. On chip guidance and recording of cardiomyocytes with 3D mushroom-shaped electrodes. NANO LETTERS 2013; 13:5379-5384. [PMID: 24088026 DOI: 10.1021/nl402901y] [Citation(s) in RCA: 47] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/02/2023]
Abstract
The quality of the recording and stimulation capabilities of multielectrode arrays (MEAs) substantially depends on the interface properties and the coupling of the cell with the underlying electrode area. The purpose of this work was the investigation of a three-dimensional nanointerface, enabling simultaneous guidance and recording of electrogenic cells (HL-1) by utilizing nanostructures with a mushroom shape on MEAs.
Collapse
Affiliation(s)
- Francesca Santoro
- Institute of Bioelectronics ICS-8/PGI-8, Forschungszentrum Jülich D-52425 Jülich, Germany
| | | | | | | |
Collapse
|
11
|
Cell adhesion promotion strategies for signal transduction enhancement in microelectrode array in vitro electrophysiology: An introductory overview and critical discussion. Curr Opin Colloid Interface Sci 2013. [DOI: 10.1016/j.cocis.2013.07.005] [Citation(s) in RCA: 67] [Impact Index Per Article: 6.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/23/2023]
|