1
|
Taghlabi KM, Cruz-Garza JG, Hassan T, Potnis O, Bhenderu LS, Guerrero JR, Whitehead RE, Wu Y, Luan L, Xie C, Robinson JT, Faraji AH. Clinical outcomes of peripheral nerve interfaces for rehabilitation in paralysis and amputation: a literature review. J Neural Eng 2024; 21:011001. [PMID: 38237175 DOI: 10.1088/1741-2552/ad200f] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/03/2023] [Accepted: 01/18/2024] [Indexed: 02/02/2024]
Abstract
Peripheral nerve interfaces (PNIs) are electrical systems designed to integrate with peripheral nerves in patients, such as following central nervous system (CNS) injuries to augment or replace CNS control and restore function. We review the literature for clinical trials and studies containing clinical outcome measures to explore the utility of human applications of PNIs. We discuss the various types of electrodes currently used for PNI systems and their functionalities and limitations. We discuss important design characteristics of PNI systems, including biocompatibility, resolution and specificity, efficacy, and longevity, to highlight their importance in the current and future development of PNIs. The clinical outcomes of PNI systems are also discussed. Finally, we review relevant PNI clinical trials that were conducted, up to the present date, to restore the sensory and motor function of upper or lower limbs in amputees, spinal cord injury patients, or intact individuals and describe their significant findings. This review highlights the current progress in the field of PNIs and serves as a foundation for future development and application of PNI systems.
Collapse
Affiliation(s)
- Khaled M Taghlabi
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
| | - Jesus G Cruz-Garza
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
| | - Taimur Hassan
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- School of Medicine, Texas A&M University, Bryan, TX 77807, United States of America
| | - Ojas Potnis
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- School of Engineering Medicine, Texas A&M University, Houston, TX 77030, United States of America
| | - Lokeshwar S Bhenderu
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- School of Medicine, Texas A&M University, Bryan, TX 77807, United States of America
| | - Jaime R Guerrero
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
| | - Rachael E Whitehead
- Department of Academic Affairs, Houston Methodist Academic Institute, Houston, TX 77030, United States of America
| | - Yu Wu
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Lan Luan
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Chong Xie
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Jacob T Robinson
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| | - Amir H Faraji
- Department of Neurological Surgery, Houston Methodist Hospital, Houston, TX 77030, United States of America
- Center for Neural Systems Restoration, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Clinical Innovations Laboratory, Houston Methodist Research Institute, Houston, TX 77030, United States of America
- Rice Neuroengineering Initiative, Rice University, Houston, TX 77005, United States of America
- Department of Electrical and Computer Engineering, Rice University, Houston, TX 77005, United States of America
| |
Collapse
|
2
|
Pellot-Cestero JE, Herring EZ, Graczyk EL, Memberg WD, Kirsch RF, Ajiboye AB, Miller JP. Implanted Electrodes for Functional Electrical Stimulation to Restore Upper and Lower Extremity Function: History and Future Directions. Neurosurgery 2023; 93:965-970. [PMID: 37288972 DOI: 10.1227/neu.0000000000002561] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/28/2023] [Accepted: 04/03/2023] [Indexed: 06/09/2023] Open
Abstract
Functional electrical stimulation (FES) to activate nerves and muscles in paralyzed extremities has considerable promise to improve outcome after neurological disease or injury, especially in individuals who have upper motor nerve dysfunction due to central nervous system pathology. Because technology has improved, a wide variety of methods for providing electrical stimulation to create functional movements have been developed, including muscle stimulating electrodes, nerve stimulating electrodes, and hybrid constructs. However, in spite of decades of success in experimental settings with clear functional improvements for individuals with paralysis, the technology has not yet reached widespread clinical translation. In this review, we outline the history of FES techniques and approaches and describe future directions in evolution of the technology.
Collapse
Affiliation(s)
- Joel E Pellot-Cestero
- Department of Neurosurgery, School of Medicine, Case Western Reserve University, Cleveland , Ohio , USA
- Department of Neurosurgery, The Neurological Institute, University Hospital Cleveland Medical Center, Cleveland , Ohio , USA
| | - Eric Z Herring
- Department of Neurosurgery, School of Medicine, Case Western Reserve University, Cleveland , Ohio , USA
- Department of Neurosurgery, The Neurological Institute, University Hospital Cleveland Medical Center, Cleveland , Ohio , USA
| | - Emily L Graczyk
- Department of Neurosurgery, School of Medicine, Case Western Reserve University, Cleveland , Ohio , USA
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland , Ohio , USA
- Louis Stokes Cleveland Department of Veterans Affairs Medical Center, FES Center of Excellence, Rehab. R&D Service, Cleveland , Ohio , USA
| | - William D Memberg
- Department of Neurosurgery, School of Medicine, Case Western Reserve University, Cleveland , Ohio , USA
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland , Ohio , USA
- Louis Stokes Cleveland Department of Veterans Affairs Medical Center, FES Center of Excellence, Rehab. R&D Service, Cleveland , Ohio , USA
| | - Robert F Kirsch
- Department of Neurosurgery, School of Medicine, Case Western Reserve University, Cleveland , Ohio , USA
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland , Ohio , USA
- Louis Stokes Cleveland Department of Veterans Affairs Medical Center, FES Center of Excellence, Rehab. R&D Service, Cleveland , Ohio , USA
| | - A Bolu Ajiboye
- Department of Neurosurgery, School of Medicine, Case Western Reserve University, Cleveland , Ohio , USA
- Department of Biomedical Engineering, Case Western Reserve University, Cleveland , Ohio , USA
- Louis Stokes Cleveland Department of Veterans Affairs Medical Center, FES Center of Excellence, Rehab. R&D Service, Cleveland , Ohio , USA
| | - Jonathan P Miller
- Department of Neurosurgery, School of Medicine, Case Western Reserve University, Cleveland , Ohio , USA
- Department of Neurosurgery, The Neurological Institute, University Hospital Cleveland Medical Center, Cleveland , Ohio , USA
- Louis Stokes Cleveland Department of Veterans Affairs Medical Center, FES Center of Excellence, Rehab. R&D Service, Cleveland , Ohio , USA
| |
Collapse
|
3
|
Akouissi O, Lacour SP, Micera S, DeSimone A. A finite element model of the mechanical interactions between peripheral nerves and intrafascicular implants. J Neural Eng 2022; 19. [PMID: 35861557 DOI: 10.1088/1741-2552/ac7d0e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2021] [Accepted: 06/29/2022] [Indexed: 11/11/2022]
Abstract
Objective.Intrafascicular peripheral nerve implants are key components in the development of bidirectional neuroprostheses such as touch-enabled bionic limbs for amputees. However, the durability of such interfaces is hindered by the immune response following the implantation. Among the causes linked to such reaction, the mechanical mismatch between host nerve and implant is thought to play a decisive role, especially in chronic settings.Approach.Here we focus on modeling mechanical stresses induced on the peripheral nerve by the implant's micromotion using finite element analysis. Through multiple parametric sweeps, we analyze the role of the implant's material, geometry (aspect-ratio and shape), and surface coating, deriving a set of parameters for the design of better-integrated implants.Main results.Our results indicate that peripheral nerve implants should be designed and manufactured with smooth edges, using materials at most three orders of magnitude stiffer than the nerve, and with innovative geometries to redistribute micromotion-associated loads to less delicate parts of the nerve such as the epineurium.Significance.Overall, our model is a useful tool for the peripheral nerve implant designer that is mindful of the importance of implant mechanics for long term applications.
Collapse
Affiliation(s)
- Outman Akouissi
- Bertarelli Foundation Chair in Neuroprosthetic Technology, Laboratory for Soft Bioelectronic Interfaces, Neuro-X Institute, Ecole Polytechnique Fédérale de Lausanne (EPFL), Geneva, 1202, Switzerland.,Bertarelli Foundation Chair in Translational Neuroengineering, Translational Neural Engineering Laboratory, Neuro-X Institute, Ecole Polytechnique Fédérale de Lausanne (EPFL), Geneva, 1202, Switzerland
| | - Stéphanie P Lacour
- Bertarelli Foundation Chair in Neuroprosthetic Technology, Laboratory for Soft Bioelectronic Interfaces, Neuro-X Institute, Ecole Polytechnique Fédérale de Lausanne (EPFL), Geneva, 1202, Switzerland
| | - Silvestro Micera
- Bertarelli Foundation Chair in Translational Neuroengineering, Translational Neural Engineering Laboratory, Neuro-X Institute, Ecole Polytechnique Fédérale de Lausanne (EPFL), Geneva, 1202, Switzerland.,The Biorobotics Institute and Department of Excellence in Robotics & AI, Health Science Interdisciplinary Center, Scuola Superiore Sant'Anna, Pisa, Italy
| | - Antonio DeSimone
- The Biorobotics Institute and Department of Excellence in Robotics & AI, Health Science Interdisciplinary Center, Scuola Superiore Sant'Anna, Pisa, Italy.,SISSA-International School for Advanced Studies, 34136 Trieste, Italy
| |
Collapse
|
4
|
Tringides CM, Mooney DJ. Materials for Implantable Surface Electrode Arrays: Current Status and Future Directions. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2107207. [PMID: 34716730 DOI: 10.1002/adma.202107207] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/10/2021] [Revised: 10/26/2021] [Indexed: 06/13/2023]
Abstract
Surface electrode arrays are mainly fabricated from rigid or elastic materials, and precisely manipulated ductile metal films, which offer limited stretchability. However, the living tissues to which they are applied are nonlinear viscoelastic materials, which can undergo significant mechanical deformation in dynamic biological environments. Further, the same arrays and compositions are often repurposed for vastly different tissues rather than optimizing the materials and mechanical properties of the implant for the target application. By first characterizing the desired biological environment, and then designing a technology for a particular organ, surface electrode arrays may be more conformable, and offer better interfaces to tissues while causing less damage. Here, the various materials used in each component of a surface electrode array are first reviewed, and then electrically active implants in three specific biological systems, the nervous system, the muscular system, and skin, are described. Finally, the fabrication of next-generation surface arrays that overcome current limitations is discussed.
Collapse
Affiliation(s)
- Christina M Tringides
- Harvard Program in Biophysics, Harvard University, Cambridge, MA, 02138, USA
- Harvard-MIT Division in Health Sciences and Technology, Massachusetts Institute of Technology, Cambridge, MA, 02139, USA
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA, 02138, USA
| | - David J Mooney
- Wyss Institute for Biologically Inspired Engineering, Harvard University, Cambridge, MA, 02138, USA
- John A. Paulson School of Engineering and Applied Sciences, Harvard University, Cambridge, MA, 02138, USA
| |
Collapse
|
5
|
Jabban L, Dupan S, Zhang D, Ainsworth B, Nazarpour K, Metcalfe BW. Sensory Feedback for Upper-Limb Prostheses: Opportunities and Barriers. IEEE Trans Neural Syst Rehabil Eng 2022; 30:738-747. [PMID: 35290188 DOI: 10.1109/tnsre.2022.3159186] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
The addition of sensory feedback to upper-limb prostheses has been shown to improve control, increase embodiment, and reduce phantom limb pain. However, most commercial prostheses do not incorporate sensory feedback due to several factors. This paper focuses on the major challenges of a lack of deep understanding of user needs, the unavailability of tailored, realistic outcome measures and the segregation between research on control and sensory feedback. The use of methods such as the Person-Based Approach and co-creation can improve the design and testing process. Stronger collaboration between researchers can integrate different prostheses research areas to accelerate the translation process.
Collapse
|
6
|
Welle EJ, Woods JE, Jiman AA, Richie JM, Bottorff EC, Ouyang Z, Seymour JP, Patel PR, Bruns TM, Chestek CA. Sharpened and Mechanically Durable Carbon Fiber Electrode Arrays for Neural Recording. IEEE Trans Neural Syst Rehabil Eng 2021; 29:993-1003. [PMID: 34014825 PMCID: PMC8459724 DOI: 10.1109/tnsre.2021.3082056] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
Bioelectric medicine treatments target disorders of the nervous system unresponsive to pharmacological methods. While current stimulation paradigms effectively treat many disorders, the underlying mechanisms are relatively unknown, and current neuroscience recording electrodes are often limited in their specificity to gross averages across many neurons or axons. Here, we develop a novel, durable carbon fiber electrode array adaptable to many neural structures for precise neural recording. Carbon fibers ( [Formula: see text] diameter) were sharpened using a reproducible blowtorchmethod that uses the reflection of fibers against the surface of a water bath. The arrays were developed by partially embedding carbon fibers in medical-grade silicone to improve durability. We recorded acute spontaneous electrophysiology from the rat cervical vagus nerve (CVN), feline dorsal root ganglia (DRG), and rat brain. Blowtorching resulted in fibers of 72.3 ± 33.5-degree tip angle with [Formula: see text] exposed carbon. Observable neural clusters were recorded using sharpened carbon fiber electrodes fromrat CVN ( [Formula: see text]), feline DRG ( [Formula: see text]), and rat brain ( [Formula: see text]). Recordings from the feline DRG included physiologically relevant signals from increased bladder pressure and cutaneous brushing. These results suggest that this carbon fiber array is a uniquely durable and adaptable neural recordingdevice. In the future, this device may be useful as a bioelectric medicine tool for diagnosis and closed-loop neural control of therapeutic treatments and monitoring systems.
Collapse
|
7
|
Iwasa SN, Shi HH, Hong SH, Chen T, Marquez-Chin M, Iorio-Morin C, Kalia SK, Popovic MR, Naguib HE, Morshead CM. Novel Electrode Designs for Neurostimulation in Regenerative Medicine: Activation of Stem Cells. Bioelectricity 2020; 2:348-361. [PMID: 34471854 PMCID: PMC8370381 DOI: 10.1089/bioe.2020.0034] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Neural stem and progenitor cells (i.e., neural precursors) are found within specific regions in the central nervous system and have great regenerative capacity. These cells are electrosensitive and their behavior can be regulated by the presence of electric fields (EFs). Electrical stimulation is currently used to treat neurological disorders in a clinical setting. Herein we propose that electrical stimulation can be used to enhance neural repair by regulating neural precursor cell (NPC) kinetics and promoting their migration to sites of injury or disease. We discuss how intrinsic and extrinsic factors can affect NPC migration in the presence of an EF and how this impacts electrode design with the goal of enhancing tissue regeneration. We conclude with an outlook on future clinical applications of electrical stimulation and highlight technological advances that would greatly support these applications.
Collapse
Affiliation(s)
- Stephanie N Iwasa
- The KITE Research Institute, Toronto Rehabilitation Institute-University Health Network, Toronto, Canada
- CRANIA, University Health Network and University of Toronto, Toronto, Canada
| | - HaoTian H Shi
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada
| | - Sung Hwa Hong
- Department of Chemical Engineering and Applied Chemistry, University of Toronto, Toronto, Canada
| | - Tianhao Chen
- Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
| | - Melissa Marquez-Chin
- The KITE Research Institute, Toronto Rehabilitation Institute-University Health Network, Toronto, Canada
- Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
| | - Christian Iorio-Morin
- Department of Neurosurgery, University Health Network, University of Toronto, Toronto, Canada
| | - Suneil K Kalia
- The KITE Research Institute, Toronto Rehabilitation Institute-University Health Network, Toronto, Canada
- CRANIA, University Health Network and University of Toronto, Toronto, Canada
- Department of Neurosurgery, University Health Network, University of Toronto, Toronto, Canada
- Krembil Research Institute, Toronto, Canada
| | - Milos R Popovic
- The KITE Research Institute, Toronto Rehabilitation Institute-University Health Network, Toronto, Canada
- CRANIA, University Health Network and University of Toronto, Toronto, Canada
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada
- Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
| | - Hani E Naguib
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada
- Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
- Department of Materials Science & Engineering, University of Toronto, Toronto, Canada
| | - Cindi M Morshead
- The KITE Research Institute, Toronto Rehabilitation Institute-University Health Network, Toronto, Canada
- CRANIA, University Health Network and University of Toronto, Toronto, Canada
- Department of Mechanical and Industrial Engineering, University of Toronto, Toronto, Canada
- Institute of Biomedical Engineering, University of Toronto, Toronto, Canada
- Department of Surgery, University of Toronto, Toronto, Canada
| |
Collapse
|
8
|
Lee MT, Chen YH, Mackie K, Chiou LC. Median Nerve Stimulation as a Nonpharmacological Approach to Bypass Analgesic Tolerance to Morphine: A Proof-of-Concept Study in Mice. THE JOURNAL OF PAIN 2020; 22:300-312. [PMID: 33069869 DOI: 10.1016/j.jpain.2020.09.003] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 09/23/2020] [Accepted: 09/25/2020] [Indexed: 02/06/2023]
Abstract
Analgesic tolerance to opioids contributes to the opioid crisis by increasing the quantity of opioids prescribed and consumed. Thus, there is a need to develop non-opioid-based pain-relieving regimens as well as strategies to circumvent opioid tolerance. Previously, we revealed a non-opioid analgesic mechanism induced by median nerve electrostimulation at the overlaying PC6 (Neiguan) acupoint (MNS-PC6). Here, we further examined the efficacy of MNS-PC6 in morphine-tolerant mice with neuropathic pain induced by chronic constriction injury (CCI) of the sciatic nerve. Daily treatments of MNS-PC6 (2 Hz, 2 mA), but not electrostimulation at a nonmedian nerve-innervated location, for a week post-CCI induction significantly suppressed established mechanical allodynia in CCI-mice in an orexin-1 (OX1) and cannabinoid-1 (CB1) receptor-dependent fashion. This antiallodynic effect induced by repeated MNS-PC6 was comparable to that induced by repeated gabapentin (50 mg/kg, i.p.) or single morphine (10 mg/kg, i.p.) treatments, but without tolerance, unlike repeated morphine-induced analgesia. Furthermore, single and repeated MNS-PC6 treatments remained fully effective in morphine-tolerant CCI-mice, also in an OX1 and CB1 receptor-dependent fashion. In CCI-mice receiving escalating doses of morphine for 21 days (10, 20 and 50 mg/kg), single and repeated MNS-PC6 treatments remained fully effective. Therefore, repeated MNS-PC6 treatments induce analgesia without tolerance, and retain efficacy in opioid-tolerant mice via a mechanism that involves OX1 and CB1 receptors. This study suggests that MNS-PC6 is an alternative pain management strategy that maybe useful for combatting the opioid epidemic, and opioid-tolerant patients receiving palliative care. PERSPECTIVE: Median nerve stimulation relieves neuropathic pain in mice without tolerance and retains efficacy even in mice with analgesic tolerance to escalating doses of morphine, via an opioid-independent, orexin-endocannabinoid-mediated mechanism. This study provides a proof of concept for utilizing peripheral nerve stimulating devices for pain management in opioid-tolerant patients.
Collapse
Affiliation(s)
- Ming Tatt Lee
- Graduate Institute of Pharmacology, College of Medicine, National Taiwan University, Taipei, Taiwan; Graduate Institute of Brain and Mind Sciences, College of Medicine, National Taiwan University, Taipei, Taiwan; Faculty of Pharmaceutical Sciences, UCSI University, Kuala Lumpur, Malaysia
| | - Yi-Hung Chen
- Graduate Institute of Acupuncture Science, China Medical University, Taichung, Taiwan; Chinese Medicine Research Center, China Medical University, Taichung, Taiwan
| | - Ken Mackie
- Gill Center for Biomolecular Research, Indiana University, Bloomington, Indiana; Department of Psychological and Brain Sciences, Indiana University, Bloomington, Indiana
| | - Lih-Chu Chiou
- Graduate Institute of Pharmacology, College of Medicine, National Taiwan University, Taipei, Taiwan; Graduate Institute of Brain and Mind Sciences, College of Medicine, National Taiwan University, Taipei, Taiwan; Graduate Institute of Acupuncture Science, China Medical University, Taichung, Taiwan.
| |
Collapse
|
9
|
Adaptive self-healing electronic epineurium for chronic bidirectional neural interfaces. Nat Commun 2020; 11:4195. [PMID: 32826916 PMCID: PMC7442836 DOI: 10.1038/s41467-020-18025-3] [Citation(s) in RCA: 37] [Impact Index Per Article: 9.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2019] [Accepted: 07/31/2020] [Indexed: 12/21/2022] Open
Abstract
Realizing a clinical-grade electronic medicine for peripheral nerve disorders is challenging owing to the lack of rational material design that mimics the dynamic mechanical nature of peripheral nerves. Electronic medicine should be soft and stretchable, to feasibly allow autonomous mechanical nerve adaptation. Herein, we report a new type of neural interface platform, an adaptive self-healing electronic epineurium (A-SEE), which can form compressive stress-free and strain-insensitive electronics-nerve interfaces and enable facile biofluid-resistant self-locking owing to dynamic stress relaxation and water-proof self-bonding properties of intrinsically stretchable and self-healable insulating/conducting materials, respectively. Specifically, the A-SEE does not need to be sutured or glued when implanted, thereby significantly reducing complexity and the operation time of microneurosurgery. In addition, the autonomous mechanical adaptability of the A-SEE to peripheral nerves can significantly reduce the mechanical mismatch at electronics-nerve interfaces, which minimizes nerve compression-induced immune responses and device failure. Though a small amount of Ag leaked from the A-SEE is observed in vivo (17.03 ppm after 32 weeks of implantation), we successfully achieved a bidirectional neural signal recording and stimulation in a rat sciatic nerve model for 14 weeks. In view of our materials strategy and in vivo feasibility, the mechanically adaptive self-healing neural interface would be considered a new implantable platform for a wide range application of electronic medicine for neurological disorders in the human nervous system. Electronic implantable devices should be soft and stretchable, such that nerves can adapt mechanically and autonomously. Here, the authors present an adaptive self-healing electronic epineurium which can form compressive stress-free and strain-insensitive electronics-nerve interfaces.
Collapse
|
10
|
Interfacing with the Peripheral Nervous System. J Neurosci Methods 2020; 340:108745. [DOI: 10.1016/j.jneumeth.2020.108745] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|