1
|
Alkindi S, Hamdoon Z, Aziz AM. Effect of different impression coping and scan body designs on the accuracy of conventional versus digital implant impressions: An in vitro study. J Dent 2024; 146:105045. [PMID: 38714241 DOI: 10.1016/j.jdent.2024.105045] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 04/15/2024] [Accepted: 05/02/2024] [Indexed: 05/09/2024] Open
Abstract
OBJECTIVES This in vitro study compared the accuracy of conventional versus digital impression techniques for angulated and straight implants using two different impression coping and scan body designs. METHODS Two implant systems were used: Straumann and Dentegris. Two implants were placed for each system, straight and angulated at 15 degrees mesiodistally. Conventional impressions were made using the splinted open-tray technique using narrow impression coping (NIC) and wide impression coping (WIC). The stone casts produced from the conventional impression were digitized with a lab scanner (3Shape D2000). Digital impressions were made using four intraoral scanners (IOS): 3Shape Trios 3, Medit i700, Cerec Omnicam, and Emerald Planmeca using short scanbodies (SSB) and long scanbodies (LSB). The scanning was repeated ten times to generate the Standard Tessellation Language (STL) files. The distance and angle deviations between impression copings and scanbodies were measured in reference to the master model. RESULTS The trueness and precision of SSB and WIC were significantly better than LSB and NIC (p<0.001). The range trueness of the platform deviation was better with SSB (37.1 to 51.9) than LSB (89.6 to 127.9 μm) and for WIC than NIC in conventional impressions (58.2 and 75.1 μm, respectively). The trueness of the angle deviation of digital scans with SSB (0.11 to 0.25 degrees) was significantly better than scans with LSB (0.31 to 0.57 degrees) and for WIC than NIC (0.21 and 0.52 degrees, respectively). The precision of the platform deviation of digital scans with SSB (12.4 to 34.5 μm) was higher than other scans and conventional impressions (42.9 to 71.4 μm). The precision of the angle deviation of Medit i700 and Trios 3 with SSB (0.17 and 0.20 degrees, respectively) was higher than other scans with SSB and conventional impressions (0.54 to 1.63 degrees). CONCLUSIONS Digital scans with SSB were more accurate than conventional splinted open-tray impressions. The type of impression coping and scanbody significantly affected the impression accuracy. CLINICAL SIGNIFICANCE The use of a short scanbody can increase the accuracy of digital impressions, and wide impression coping can increase the accuracy of conventional impressions, resulting in improved clinical outcomes.
Collapse
Affiliation(s)
| | - Zaid Hamdoon
- Department of Oral and Craniofacial Health Sciences, College of Dental Medicine, University of Sharjah, Sharjah, UAE
| | - Ahmed M Aziz
- Department of Restorative Dentistry, College of Dental Medicine, University of Sharjah, Sharjah, UAE.
| |
Collapse
|
2
|
Ashry A, Abdelhamid AM, Ezzelarab S, Khamis MM. Effect of using scan body accessories and inter-implant distances on the accuracy of complete arch implant digital impressions: An in vitro study. J Prosthodont 2024. [PMID: 38594949 DOI: 10.1111/jopr.13856] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2023] [Accepted: 03/23/2024] [Indexed: 04/11/2024] Open
Abstract
PURPOSE To introduce a novel design for scan body accessory parts that are reusable, easy to attach and detach without permanent change of the scan body, and can be used with different inter-implant distances to enhance the accuracy of complete arch implant scans. MATERIALS AND METHODS A maxillary polymethylmethacrylate (PMMA) model with a soft tissue replica was fabricated with four implant analogs located at tooth positions 17, 13, 22, and 27 with 18, 25, and 30 mm inter-implant distances. Four scan bodies (SBs) were attached to the implants. The model was scanned with a laboratory scanner to be used as a reference scan. A total of 40 scans were made with the same intraoral scanner and they were divided equally into two groups. Group A: Complete arch implant scans without scan body accessories (n = 20), and Group B: Complete arch implant scans with scan body accessories (n = 20). Intraoral scans were exported and superimposed on the reference scan using reverse engineering inspection software to be evaluated for 3D deviations, angular deviations, and linear deviations. Statistical analysis was performed with student t-test and analysis of variance (ANOVA) with repeated measures followed by post hoc adjusted Bonferroni test. The level of significance was set at P = 0.05. RESULTS The scan body accessories decreased both the 3D and linear deviations, with a statistically significant difference at SB4 for the 3D deviation (P = 0.043) and the linear inter-implant discrepancies between SB1-SB2 and SB3-SB4 (P = 0.029 and < 0.001), respectively. However, there was no statistically significant difference in angular deviation between the study groups. Implant positions had significant differences within each group. CONCLUSIONS A significant improvement in the accuracy of the complete arch implant digital impression was achieved by using the scan body accessories, particularly in reducing the 3D and linear deviations at the most distant implant positions.
Collapse
Affiliation(s)
- Amal Ashry
- Department of Prosthodontics, Faculty of Dentistry, Damanhour University, El-Behaira, Egypt
- Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Ahmed M Abdelhamid
- Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Salah Ezzelarab
- Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| | - Mohamed Moataz Khamis
- Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Alexandria, Egypt
| |
Collapse
|
3
|
Kropfeld J, Berger L, Adler W, Schulz KL, Motel C, Wichmann M, Matta RE. Impact of Scanbody Geometry and CAD Software on Determining 3D Implant Position. Dent J (Basel) 2024; 12:94. [PMID: 38668006 PMCID: PMC11049057 DOI: 10.3390/dj12040094] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2024] [Revised: 03/28/2024] [Accepted: 03/31/2024] [Indexed: 04/28/2024] Open
Abstract
The implementation of CAD software in the digital production of implant prosthetics stands as a pivotal aspect of clinical dentistry, necessitating high precision in the alignment of implant scanbodies. This study investigates the influence of scanbody geometry and the method of superimposing in CAD software when determining 3D implant position. A standardized titanium model with three bone-level implants was digitized to create reference STL files, and 10 intraoral scans were performed on Medentika and NT-Trading scanbodies. To determine implant position, the generated STL files were imported into the Exocad CAD software and superimposed-automatically and manually-with the scanbody geometries stored within the software's shape library. Position accuracy was determined by a comparison of the 3D-defined scanbody points from the STL matching files with those from the reference STL files. The R statistical software was used for the evaluation of the data. In addition, mixed linear models and a significance level of 0.05 were applied to calculate the p-values. The manual overlay method was significantly more accurate than the automatic overlays for both scanbody types. The Medentika scanbodies showed slightly superior precision compared to the NT-Trading scanbodies. Both scanbody geometry and the type of alignment in the CAD software significantly affect digital workflow accuracy. Manual verification and adjustment of the automatic alignment process are essential for precise implant positioning.
Collapse
Affiliation(s)
- Judith Kropfeld
- Department of Prosthodontics, University Hospital Erlangen, Glückstrasse 11, 91054 Erlangen, Germany; (J.K.); (L.B.); (C.M.); (M.W.)
| | - Lara Berger
- Department of Prosthodontics, University Hospital Erlangen, Glückstrasse 11, 91054 Erlangen, Germany; (J.K.); (L.B.); (C.M.); (M.W.)
| | - Werner Adler
- Institute of Medical Informatics, Biometry and Epidemiology (IMBE) of the Friedrich-Alexander-University, Erlangen-Nuremberg, Waldstrasse 6, 91054 Erlangen, Germany;
| | - Katja Leonie Schulz
- Department of Oral and Cranio-Maxillofacial Surgery, University Hospital Erlangen, Glückstrasse 11, 91054 Erlangen, Germany;
| | - Constantin Motel
- Department of Prosthodontics, University Hospital Erlangen, Glückstrasse 11, 91054 Erlangen, Germany; (J.K.); (L.B.); (C.M.); (M.W.)
| | - Manfred Wichmann
- Department of Prosthodontics, University Hospital Erlangen, Glückstrasse 11, 91054 Erlangen, Germany; (J.K.); (L.B.); (C.M.); (M.W.)
| | - Ragai Edward Matta
- Department of Prosthodontics, University Hospital Erlangen, Glückstrasse 11, 91054 Erlangen, Germany; (J.K.); (L.B.); (C.M.); (M.W.)
| |
Collapse
|
4
|
Palantza E, Sykaras N, Zoidis P, Kourtis S. In vitro comparison of accuracy between conventional and digital impression using elastomeric materials and two intra-oral scanning devices. J ESTHET RESTOR DENT 2024. [PMID: 38534043 DOI: 10.1111/jerd.13227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/22/2023] [Revised: 03/08/2024] [Accepted: 03/14/2024] [Indexed: 03/28/2024]
Abstract
AIM The aim of this study was to compare the accuracy of full-arch conventional implant impressions using two different materials (A-silicone and polyether) to full-arch digital implant impressions produced from two intraoral scanning devices. MATERIALS AND METHODS A master model was fabricated representing an edentulous mandible with four implants with internal connection placed at the sites of canines and first molars. The anterior implants were parallel to the residual ridge, while the two posterior implants had an angulation of 15° to the distal and 15° to the lingual respectively. The conventional technique was performed with open-tray of non-splinted impression copings. Two different impression materials were used, A-silicone and polyether at monophase medium body consistencies. The digital impressions were obtained with the use of two different intraoral scanners, after the connection of scan bodies. A total of 10 impressions were produced for each of the four experimental groups. The conventional models as well as the master model were digitized using a high-resolution laboratory scanner. The STL files of the models and of the intraoral impressions were imported in a powerful superimposition software, for the conduction of measurements in pairs of files. The software calculated the 3D deviations, as well as the linear and angular displacements among scan bodies at the digital files. For "trueness" measurements every STL file of each experimental group was superimposed to the digital master model, while for "precision" measurements all STL files of each experimental group were superimposed to each other. RESULTS AND CONCLUSIONS The accuracy of full arch mandibular implant impressions was influenced both by the impression technique used (conventional vs. digital) and the impression material used (A-silicone vs. polyether) or the intraoral scanner used (Trios vs. Heron). In terms of "trueness," A-silicone showed the highest impression accuracy with the lowest deviation values, followed by polyether and Trios, but the differences between the three groups were in the majority not statistically significant. Heron showed statistically lower accuracy results in all measurements compared to the other groups. In terms of "precision", conventional impressions with the use of A-Silicone or polyether were statistically significantly superior to digital impressions with either scanner. A-Silicone and polyether showed no statistically significant difference between them.
Collapse
Affiliation(s)
- Eirini Palantza
- Department of Prosthodontics, Dental School, National and Kapodistrian University of Athens, Athens, Greece
| | - Nikitas Sykaras
- Department of Prosthodontics, Dental School, National and Kapodistrian University of Athens, Athens, Greece
| | - Panagiotis Zoidis
- Division Prosthodontics, Department of Restorative Dentistry, College of Dentistry, University of Florida, Gainsville, Florida, USA
| | - Stefanos Kourtis
- Department of Prosthodontics, Dental School, National and Kapodistrian University of Athens, Athens, Greece
| |
Collapse
|
5
|
Revilla-León M, Barmak AB, Lanis A, Kois JC. Influence of connected and nonconnected calibrated frameworks on the accuracy of complete arch implant scans obtained by using four intraoral scanners, a desktop scanner, and a photogrammetry system. J Prosthet Dent 2024:S0022-3913(24)00048-9. [PMID: 38443245 DOI: 10.1016/j.prosdent.2024.01.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2023] [Revised: 01/17/2024] [Accepted: 01/19/2024] [Indexed: 03/07/2024]
Abstract
STATEMENT OF PROBLEM Different techniques have been proposed for increasing the accuracy of complete arch implant scans obtained by using intraoral scanners (IOSs), including a calibrated metal framework (IOSFix); however, its accuracy remains uncertain. PURPOSE The purpose of this in vitro study was to compare the accuracy of complete arch scans obtained with connecting and non-connecting the implant scan bodies (ISBs) recorded using intraoral scanners (IOSs), a laboratory scanner (LBS), and photogrammetry (PG). MATERIAL AND METHODS A cast with 6 implant abutment analogs was obtained. Six groups were created: TRIOS 4, i700, iTero, CS3800, LBS, and PG groups. The IOSs and LBS groups were divided into 3 subgroups: nonconnected ISBs (ISB), splinted ISBs (SSB), and calibrated framework (CF), (n=15). For the ISB subgroups, an ISB was positioned on each implant abutment analog. For the SSB subgroups, a printed framework was used to connect the ISBs. For the CF subgroups, a calibrated framework (IOSFix) was used to connect the ISBs. For the PG group, scans were captured using a PG (PIC Camera). Implant positions of the reference cast were measured using a coordinate measurement machine, and Euclidean distances were used as a reference to calculate the discrepancies using the same distances obtained on each experimental scan. Wilcoxon squares 2-way ANOVA and pairwise multiple comparisons were used to analyze trueness (α=.05). The Levene test was used to analyze precision (α=.05). RESULTS Linear and angular discrepancies were found among the groups (P<.001) and subgroups (P<.001). Linear (P=.008) and angular (P<.001) precision differences were found among the subgroups. CONCLUSIONS The digitizing method and technique impacted the trueness and precision of the implant scans. The photogrammetry and calibrated framework groups obtained the best accuracy. Except for TRIOS 4, the calibrated framework method improved the accuracy of the scans obtained by using the IOSs tested.
Collapse
Affiliation(s)
- Marta Revilla-León
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash.; Faculty and Director, Research and Digital Dentistry, Kois Center, Seattle, Wash.; and Adjunct Professor, Graduate Prosthodontics, Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Mass.
| | - Abdul B Barmak
- Assistant Professor, Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY
| | - Alejandro Lanis
- Director, Advanced Graduate Education in Implant Dentistry, Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Mass
| | - John C Kois
- Founder and Director, Kois Center, Seattle, Wash; Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, University of Washington, Seattle, Wash; and Private practice, Seattle, Wash
| |
Collapse
|
6
|
Michelinakis G, Apostolakis D, Nikolidakis D, Blum IR. A comprehensive review and update on the current state of computer-assisted rehabilitation in implant dentistry. Prim Dent J 2024; 13:64-73. [PMID: 38424692 DOI: 10.1177/20501684241231672] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/02/2024]
Abstract
AIM This paper provides a comprehensive review of the established concepts and newer developments related to computer-assisted implant rehabilitation. METHODS Two independent researchers searched the English literature published to 31st December 2023 in the PubMed/Medline database for primary and secondary research and related publications on computer-assisted implant planning, computer-assisted implant placement and computer-assisted implant restoration. RESULTS A total of 58,923 papers were identified, 198 relevant papers were read in full text and 110 studies were finally included. Computer-assisted implant rehabilitation was found to result in more precise implant positioning than freehand placement. Advantages include reduced trauma and surgery time; disadvantages include reduced primary implant stability and higher cost. CONCLUSION Computer-assisted surgery is particularly indicated in cases of critical anatomy, but may encounter limitations in terms of cost, restricted mouth opening, visibility and adjustment of the surgical guides and the need for prior familiarisation with the procedure. Nonetheless, this surgical technique reduces the post-implant placement complication rate.
Collapse
Affiliation(s)
- George Michelinakis
- George Michelinakis DDS, MSc, MPhil Prosthodontist, Crete Implants Private Dental Practice, Heraklion, Crete, Greece
- Dimitrios Apostolakis DDS, MSc, MSc Radiologist, Dental Radiology in Crete, Heraklion, Crete, Greece
- Dimitrios Nikolidakis DDS, MSc, PhD Periodontist, Clinic Perio, Private Dental Practice, Heraklion, Crete, Greece
- Igor R. Blum DDS, PhD, Dr Med Dent, MSc, MA (Educ), MFDS RCS (Eng), MFDS RCS (Edin), FDS (Rest Dent) RCS (Eng), FFDRCSI, FCGDent, PGCHE, FHEA, FICD, LLM (Medico-Legal Law) Professor/Consultant & Specialist in Restorative Dentistry, Faculty of Dentistry, Oral & Craniofacial Sciences, King's College London, London, UK
| | - Dimitrios Apostolakis
- George Michelinakis DDS, MSc, MPhil Prosthodontist, Crete Implants Private Dental Practice, Heraklion, Crete, Greece
- Dimitrios Apostolakis DDS, MSc, MSc Radiologist, Dental Radiology in Crete, Heraklion, Crete, Greece
- Dimitrios Nikolidakis DDS, MSc, PhD Periodontist, Clinic Perio, Private Dental Practice, Heraklion, Crete, Greece
- Igor R. Blum DDS, PhD, Dr Med Dent, MSc, MA (Educ), MFDS RCS (Eng), MFDS RCS (Edin), FDS (Rest Dent) RCS (Eng), FFDRCSI, FCGDent, PGCHE, FHEA, FICD, LLM (Medico-Legal Law) Professor/Consultant & Specialist in Restorative Dentistry, Faculty of Dentistry, Oral & Craniofacial Sciences, King's College London, London, UK
| | - Dimitrios Nikolidakis
- George Michelinakis DDS, MSc, MPhil Prosthodontist, Crete Implants Private Dental Practice, Heraklion, Crete, Greece
- Dimitrios Apostolakis DDS, MSc, MSc Radiologist, Dental Radiology in Crete, Heraklion, Crete, Greece
- Dimitrios Nikolidakis DDS, MSc, PhD Periodontist, Clinic Perio, Private Dental Practice, Heraklion, Crete, Greece
- Igor R. Blum DDS, PhD, Dr Med Dent, MSc, MA (Educ), MFDS RCS (Eng), MFDS RCS (Edin), FDS (Rest Dent) RCS (Eng), FFDRCSI, FCGDent, PGCHE, FHEA, FICD, LLM (Medico-Legal Law) Professor/Consultant & Specialist in Restorative Dentistry, Faculty of Dentistry, Oral & Craniofacial Sciences, King's College London, London, UK
| | - Igor R Blum
- George Michelinakis DDS, MSc, MPhil Prosthodontist, Crete Implants Private Dental Practice, Heraklion, Crete, Greece
- Dimitrios Apostolakis DDS, MSc, MSc Radiologist, Dental Radiology in Crete, Heraklion, Crete, Greece
- Dimitrios Nikolidakis DDS, MSc, PhD Periodontist, Clinic Perio, Private Dental Practice, Heraklion, Crete, Greece
- Igor R. Blum DDS, PhD, Dr Med Dent, MSc, MA (Educ), MFDS RCS (Eng), MFDS RCS (Edin), FDS (Rest Dent) RCS (Eng), FFDRCSI, FCGDent, PGCHE, FHEA, FICD, LLM (Medico-Legal Law) Professor/Consultant & Specialist in Restorative Dentistry, Faculty of Dentistry, Oral & Craniofacial Sciences, King's College London, London, UK
| |
Collapse
|
7
|
Saaedi TMASE, Thabet YG. Customized scan bodies to facilitate intraoral scanning for full arch implant prosthesis: A dental technique. J Prosthodont 2024; 33:297-300. [PMID: 37435784 DOI: 10.1111/jopr.13728] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/26/2023] [Accepted: 06/29/2023] [Indexed: 07/13/2023] Open
Abstract
This article presents the design of customized resin scan bodies with different forms and their use to facilitate intraoral scanning of a maxillary full arch implant case with five implants. The aim is to limit the distance between the scan bodies and to create definite landmarks to facilitate the scanning process in full arch implant cases.
Collapse
Affiliation(s)
| | - Yasmine Galaleldin Thabet
- Oral and Maxillofacial Prosthodontics Department, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| |
Collapse
|
8
|
Zhang T, Yang B, Ge R, Zhang C, Zhang H, Wang Y. Effect of a Novel 'Scan Body' on the In Vitro Scanning Accuracy of Full-Arch Implant Impressions. Int Dent J 2024:S0020-6539(24)00039-X. [PMID: 38368235 DOI: 10.1016/j.identj.2024.01.015] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2023] [Revised: 01/18/2024] [Accepted: 01/22/2024] [Indexed: 02/19/2024] Open
Abstract
OBJECTIVE This in vitro study aimed to determine whether a newly designed arcuate scan body can improve intraoral scanning accuracy for implant rehabilitation of edentulous jaws. MATERIAL AND METHODS A master model containing 4 implant abutment replicas was fabricated and digitized with different scan bodies using an intraoral scanner. Four types of scan bodies were evaluated: original scan bodies (group OS), computer-aided design and computer-aided manufacturing (CAD/CAM) scan bodies without extension (group CS), CAD/CAM scan bodies with straight extension (group CSS), and CAD/CAM scan bodies with arcuate extension (group CSA). Conventional splinted open-tray impressions (group CI) were used as controls. The master model and the poured casts were digitized using a laboratory scanner. Impressions were repeated 10 times each in 5 groups. Scans in standard tessellation language format were exported to reverse engineering software and root mean square (RMS) values were used for trueness and precision assessments. In each group, 45 RMS values were acquired for precision evaluation and 10 RMS values were obtained for trueness assessment. Statistical evaluation was performed with the Kruskal-Wallis test and Dunn-Bonferroni test (α = 0.05). RESULTS The median trueness values were 41.40, 55.95, 39.80, 39.75, and 22.30 μm for group OS, CS, CSS, CSA, and CI, respectively. CI showed better trueness than OS (P = .020), CS (P < .001), and CSS (P = .035). The median precisions for group OS, CS, CSS, CSA, and CI were 47.40, 51.50, 43.90, 25.20, and 24.60 μm. respectively. The precision of CSA and CI were higher than OS (P < .001), CS (P < .001), and CSS (P < .001). Between CI and CSA, there was no significant difference (P = 1.000). CONCLUSIONS For full-arch implant rehabilitation, the scan body with arcuate extension could improve the intraoral scanning precision and showed similar 3-dimensional discrepancy compared to conventional splinted open-tray impressions.
Collapse
Affiliation(s)
- Tingting Zhang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangdong Provincial Clinical Research Center of Oral Diseases, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, Guangdong, China
| | - Bo Yang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangdong Provincial Clinical Research Center of Oral Diseases, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, Guangdong, China
| | - Ruihan Ge
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangdong Provincial Clinical Research Center of Oral Diseases, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, Guangdong, China
| | | | - Hui Zhang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangdong Provincial Clinical Research Center of Oral Diseases, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, Guangdong, China.
| | - Yan Wang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-sen University, Guangdong Provincial Clinical Research Center of Oral Diseases, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou, Guangdong, China.
| |
Collapse
|
9
|
Marshaha NJ, Azhari AA, Assery MK, Ahmed WM. Evaluation of the trueness and precision of conventional impressions versus digital scans for the all-on-four treatment in the maxillary arch: An in vitro study. J Prosthodont 2024; 33:171-179. [PMID: 36811911 DOI: 10.1111/jopr.13666] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/21/2022] [Revised: 01/07/2023] [Accepted: 02/05/2023] [Indexed: 02/24/2023] Open
Abstract
PURPOSE To compare the accuracy of digitizing conventional impressions to intraoral surface scans for all-on-four treatment in the maxillary arch. MATERIALS AND METHODS An edentulous maxillary arch model with four implants placed in an all-on-four design was fabricated. Intraoral surface scans (n = 10) were obtained using an intraoral scanner after scan body insertion. For conventional polyvinylsiloxane impressions of the model, implant copings were inserted into the implant fixation for implant level, opened tray impressions (n = 10). The model and conventional impressions were digitized to obtain digital files. A reference file was created using a laboratory-scanned conventional standard tessellation language (STL) file with analog to scan the body using exocad software. STL datasets from the two digital and conventional impression groups were superimposed with reference files to assess the 3D deviations. Two-way ANOVA and paired-samples t-test was performed to assess the difference in trueness and examine the effects of impression technique and implant angulation on the deviation amount. RESULTS No significant differences were found between the conventional impression and intraoral surface scan groups F(1, 76) = 2.705, p = 0.104. No significant differences were found between conventional straight and digital straight implants and between conventional and digital tilted implants F(1, 76) = .041, p = 0.841. No significant differences were found between conventional straight and conventional tilted implants p = 0.07 and between digital straight and digital tilted implants p = 0.08. CONCLUSION Digital scans were more accurate than conventional impressions. The digital straight implants were more accurate than the conventional straight implants, and the digital tilted implants were more accurate than the conventional tilted implants, with higher accuracy for digital straight implants.
Collapse
Affiliation(s)
- Nour Jamal Marshaha
- Graduate Prosthodontics, Prosthodontics, Faculty of Dentistry, Riyadh Elm University, Riyadh, Saudi Arabia
| | - Amr Ahmed Azhari
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| | - Mansour K Assery
- Department of Prosthodontics, College of Dentistry, Riyadh Elm University, Riyadh, Saudi Arabia
| | - Walaa Magdy Ahmed
- Department of Restorative Dentistry, Faculty of Dentistry, King Abdulaziz University, Jeddah, Saudi Arabia
| |
Collapse
|
10
|
Rutkunas V, Dirse J, Kules D, Mischitz I, Larsson C, Janda M. Misfit simulation on implant prostheses with different combinations of engaging and nonengaging titanium bases. Part 2: Screw resistance test. J Prosthet Dent 2024; 131:262-271. [PMID: 35981927 DOI: 10.1016/j.prosdent.2022.04.027] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2021] [Revised: 04/24/2022] [Accepted: 04/25/2022] [Indexed: 11/19/2022]
Abstract
STATEMENT OF PROBLEM Prosthesis fit is 1 of the main factors influencing the success and survival of an implant-supported screw-retained restoration. However, scientific validation of the performance of engaging and nonengaging components in a fixed partial denture (FPD) and the effect of their combinations on the fit of FPDs is lacking. The screw resistance test has been used for the fit assessment of screw-retained FPDs. However, objective assessments by using analog and digital devices are now available. PURPOSE The purpose of this in vitro study was to investigate the effect of engaging and nonengaging components on the fit of screw-retained frameworks, supported by 2 conical connection implants with simulated vertical and horizontal misfits, by performing 2 different screw resistance tests (analog and digital). MATERIAL AND METHODS Thirty 2-implant-supported bar-shaped zirconia frameworks cemented on two 2-mm titanium bases were fabricated and divided into 3 groups (n=10) according to different abutment combinations: both engaging, engaging and nonengaging, both nonengaging. The fit of each framework was tested on the control cast and on 6 definitive casts simulating 50-, 100-, and 150-μm vertical and 35-, 70-, and 100-μm horizontal misfit levels. The abutment screws were tightened on each implant, and the screw rotation angle was measured both digitally, with a custom-made digital torque wrench and a computer software program, and conventionally, with an analog torque wrench and protractor. Clearly ill-fitting specimens were excluded. The data were statistically analyzed by 1-way analysis of variance (ANOVA) and the Tukey post hoc test (α=.05). RESULTS Both engaging specimens on the 100-μm horizontal misfit group and on all vertical misfit groups were clearly ill-fitting and excluded. Statistically significant differences among groups with different combinations of abutments were found (P<.05). The engaging abutments had a higher angle of rotation than the nonengaging abutments on all casts. In the horizontal misfit group, both engaging specimens had the highest angle of rotation, followed by engaging and nonengaging and both engaging specimens. In the vertical misfit group, the engaging and nonengaging specimens had the highest angle of rotation on the side of the engaging abutment. The angle of rotation increased with the increasing level of misfit. CONCLUSIONS Both nonengaging frameworks showed superiority in misfit tolerance, as the angle of rotation was lower than that of the engaging and nonengaging and both engaging frameworks. Conventional and digital torque wrenches showed similar results.
Collapse
Affiliation(s)
- Vygandas Rutkunas
- Professor, Department of Prosthodontics, Faculty of Medicine, Institute of Odontology, Vilnius University, Vilnius, Lithuania
| | - Julius Dirse
- Postgraduate student, Faculty of Medicine, Institute of Odontology, Vilnius University, Vilnius, Lithuania
| | - Daniel Kules
- Undergraduate student, Faculty of Medicine, Institute of Odontology, Vilnius University, Vilnius, Lithuania
| | - Ingrida Mischitz
- Dental Research Assistant, Department of Dental Medicine and Oral Health, Medical University of Graz, Graz, Austria
| | - Christel Larsson
- Associate Professor, Faculty of Odontology, Malmö University, Malmö, Sweden
| | - Martin Janda
- Assistant Professor, Faculty of Odontology, Malmö University, Malmö, Sweden.
| |
Collapse
|
11
|
Pozzi A, Agliardi E, Lio F, Nagy K, Nardi A, Arcuri L. Accuracy of intraoral optical scan versus stereophotogrammetry for complete-arch digital implant impression: An in vitro study. J Prosthodont Res 2024; 68:172-180. [PMID: 37574278 DOI: 10.2186/jpr.jpr_d_22_00251] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/15/2023]
Abstract
PURPOSE To assess and compare the accuracies of intraoral scanners (IOS) and stereophotogrammetry (SPG) devices for complete-arch digital implant impressions. METHODS A 4-analog model was digitized using a desk scanner to obtain a reference file. Thirty test scans were conducted using the investigated IOS device, while an additional 30 scans were performed using the SPG device. Using the best-fit algorithm, the resulting 60 test files were aligned with the reference file. Linear (ΔX, ΔY, and ΔZ-axis) and angular deviations (ΔANGLE) were evaluated. Three-dimensional (3D) deviation was calculated based on the Euclidean distance (ΔEUC). The analysis was stratified according to the scanning device and implant position. Fisher's F and t-tests were used to compare the variances and expected values of the two scanning systems. RESULTS IOS expressed a higher 3D (ΔEUC) mean deviation than SPG (52.8 µm vs. 33.4 µm, P < 0.0001), with extreme measurements up to 181.9 µm. A significantly higher standard deviation (SD) was associated with IOS (37.1 µm vs. 17.7 µm, P < 0.0001). Considering angular deviations, the IOS showed slightly higher angular mean deviations (ΔANGLE) than the SPG (0.28° vs. 0.24°, P = 0.0022), with extreme measurements of up to 0.73°. The SPG SD values were significantly lower than the IOS SD values (0.14° vs. 0.04°, P < 0.0001). CONCLUSIONS The SPG showed significantly higher 3D and angular accuracies for complete arch implant impressions, with consistent repeatability. IOS scanning revealed significantly higher extreme deviations exceeding the acceptable threshold value. Despite study limitations, SPG appears more feasible than IOS for complete-arch digital implant impressions.
Collapse
Affiliation(s)
- Alessandro Pozzi
- Goldstein Center for Esthetic and Implant Dentistry, Department of Restorative Sciences, Augusta University, Augusta, USA
- Department of Clinical Sciences and Translational Medicine, School of Dentistry, University of Tor Vergata, Rome, Italy
| | - Enrico Agliardi
- Dentistry Department, Vita e Salute San Raffaele University, Milan, Italy
| | - Fabrizio Lio
- Department of Chemical Science and Technologies, Materials for Health, Environment and Energy - Dentistry, University of Tor Vergata, Rome, Italy
| | - Katalin Nagy
- Department of Oral Surgery, University of Szeged, Szeged, Hungary
| | - Alessandra Nardi
- Department of Mathematics, University of Rome Tor Vergata, Rome, Italy
| | - Lorenzo Arcuri
- Department of Odontostomatological and Maxillofacial Sciences, Sapienza University, Rome, Italy
| |
Collapse
|
12
|
Wu HK, Chen G, Wang J, Zhang Z, Huang X, Lin X, Deng F, Li Y. Effect of prefabricated auxiliary devices and scanning patterns on the accuracy of complete-arch implant digital impressions. J Dent 2024; 140:104788. [PMID: 37992957 DOI: 10.1016/j.jdent.2023.104788] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/18/2023] [Revised: 11/15/2023] [Accepted: 11/19/2023] [Indexed: 11/24/2023] Open
Abstract
OBJECTIVES This study aimed to evaluate the impact of prefabricated auxiliary devices (PAD) and scanning patterns on the accuracy of complete-arch implant digital impressions. METHODS An edentulous maxillary model was inserted with four parallel implant analogs and four PAD. The model was scanned with D2000 dental laboratory scanner as the reference scans. Test scans were obtained by 8 different scanning patterns (SP), which including SPA, SPB, SPC, SPD, SPE, SPF, SPG and SPH, with (test group) or without (control group) using the PAD by an intraoral scanner (Aoralscan 3, 3DShining). SPA was the scanning pattern recommended by the manufacturer. Each scanning time was recorded. The related files were imported into inspection software for assessment. Aligned Ranks Transformation ANOVA, Kruskal-Wallis and Mann-Whitney tests were used to evaluate the values. The level of significance was set at α = 0.05. RESULTS The scanning patterns significantly influenced the linear accuracy in the test group and the scanning time for both groups. Lower linear trueness in the test group was found in SPF (p<0.05) and SPG (p<0.05). Longer scanning time was found in SPB and SPG for both groups. The test group demonstrated linear accuracy enhancement in all the scanning patterns; angular trueness enhancement was seen in SPA (p<0.05), SPC (p<0.01) and SPH (p<0.01). Significant longer scanning time was found in SPB (p<0.05), SPF (p<0.05), SPG (p<0.05) and SPH (p<0.05) when using PAD. CONCLUSION The scanning patterns impact the accuracy differently depending on the PAD's existence. The scanning time can be significantly influenced by the scanning patterns and the PAD. CLINICAL SIGNIFICANCE In daily clinical practice, selecting a suitable scanning pattern is significant in achieving accurate digital impressions. The PAD demonstrated effective linear accuracy enhancement in all the scanning patterns tested.
Collapse
Affiliation(s)
- Hio Kuan Wu
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China
| | - Guanhui Chen
- Department of Stomatology, the Seventh Affiliated Hospital, Sun Yat-sen University, Shenzhen, Guangdong 518107, PR China
| | - Jing Wang
- YangHe Dental Clinic, Guangzhou 510055, PR China
| | - Zhengchuan Zhang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China
| | - Xiaoqiong Huang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China
| | - Xiaoxuan Lin
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China
| | - Feilong Deng
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China
| | - Yiming Li
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, PR China.
| |
Collapse
|
13
|
Meneghetti PC, Li J, Borella PS, Mendonça G, Burnett LH. Influence of scanbody design and intraoral scanner on the trueness of complete arch implant digital impressions: An in vitro study. PLoS One 2023; 18:e0295790. [PMID: 38113200 PMCID: PMC10729975 DOI: 10.1371/journal.pone.0295790] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Accepted: 11/28/2023] [Indexed: 12/21/2023] Open
Abstract
This study aimed to compare the accuracy of full-arch digital implant impressions using seven different scanbodies and four intraoral scanners. A 3D-printed maxillary model with six implants and their respective multi-unit abutments was used for this study. Seven scanbodies (SB1, SB2, SB3, SB4, SB5, SB6, and SB7) and four intraoral scanners (Primescan®, Omnican®, Trios 3®, and Trios 4®) were assessed. Each combination group was scanned ten times and a dental lab scanner (D2000, 3Shape) was used as a reference. All scans were exported as STL files, imported into Convince software (3Shape) for alignment, and later into Blender software, where their 3D positions were analyzed using a Python script. The 3D deviation, angular deviation, and linear distance between implants #3 and #14 were also measured. Accuracy was measured in terms of "trueness" (scanbody 3D deviation between intraoral scan and desktop scan). Kruskal-Wallis followed by the Bonferroni correction was used to analyze the data (⍺ = .05). The study found statistically significant differences in digital impression accuracy among the scanners and scanbodies (p<0.001). When comparing different intraoral scanners, the Primescan system showed the smallest 3D deviation (median 110.59 μm) and differed statistically from the others, while Trios 4 (median 122.35 μm) and Trios 3 (median 130.62 μm) did not differ from each other (p = .284). No differences were found in the linear distance between implants #3 and #14 between Trios 4, Primescan, and Trios 3 systems. When comparing different scanbodies, the lowest median values for 3D deviation were obtained by SB2 (72.27μm) and SB7 (93.31μm), and they did not differ from each other (p = .116). The implant scanbody and intraoral scanner influenced the accuracy of digital impressions on completely edentulous arches.
Collapse
Affiliation(s)
- Priscila Ceolin Meneghetti
- School of Health and Life Sciences, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
- Department of Biological and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Michigan, United States of America
| | - Junying Li
- Department of Biological and Materials Sciences & Prosthodontics, University of Michigan School of Dentistry, Ann Arbor, Michigan, United States of America
| | - Paulo Sérgio Borella
- Department of General Practice, Virginia Commonwealth University School of Dentistry, Richmond, Virginia, United States of America
- Department of Occlusion, Fixed Prosthodontics, and Dental Materials, Federal University of Uberlândia, Uberlândia, Minas Gerais, Brazil
| | - Gustavo Mendonça
- Department of General Practice, Virginia Commonwealth University School of Dentistry, Richmond, Virginia, United States of America
| | - Luiz Henrique Burnett
- School of Health and Life Sciences, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, Rio Grande do Sul, Brazil
| |
Collapse
|
14
|
Gómez-Polo M, Donmez MB, Çakmak G, Yilmaz B, Revilla-León M. Influence of implant scan body design (height, diameter, geometry, material, and retention system) on intraoral scanning accuracy: A systematic review. J Prosthodont 2023; 32:165-180. [PMID: 37771200 DOI: 10.1111/jopr.13774] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2023] [Revised: 09/20/2023] [Accepted: 09/23/2023] [Indexed: 09/30/2023] Open
Abstract
PURPOSE To evaluate the influence of implant scan body (ISB) design (height, diameter, geometry, material, and retention system) on the accuracy of digital implant scans. MATERIAL AND METHODS A literature search was completed in five databases: PubMed/Medline, Scopus, Embase, World of Science, and Cochrane. A manual search was also conducted. Studies reporting the evaluation of ISB design on the accuracy of digital scans obtained by using IOSs were included. Two investigators evaluated the studies independently by applying the Joanna Briggs Institute critical appraisal. A third examiner was consulted to resolve any lack of consensus. Articles were classified based on the ISB features of height, geometry, material, and retention system. RESULTS Twenty articles were included. Among the reviewed studies, 11 investigations analyzed the influence of different ISB geometries, 1 study assessed the impact of ISB diameter, 4 studies investigated the effect of ISB splinting, 2 articles evaluated ISB height, and 2 studies focused on the effect of ISB material on scan accuracy. In addition, 8 studies involved ISBs fabricated with different materials (1- and 2-piece polyetheretherketone and 1-piece titanium ISBs), and all of the reviewed articles tested screw-retained ISBs, except for 3 in vitro studies. CONCLUSIONS The findings did not enable concrete conclusions regarding the optimal ISB design, whether there is a relationship between IOS technology and a specific ISB design, or the clinical condition that maximizes intraoral scanning accuracy. Research efforts are needed to identify the optimal ISB design and its possible relationship with the IOS selected for acquiring intraoral digital implant scans.
Collapse
Affiliation(s)
- Miguel Gómez-Polo
- Department of Prosthetic Dentistry, Faculty of Dentistry, Complutense University of Madrid, Madrid, Spain
| | - Mustafa Borga Donmez
- Department of Prosthodontics, Faculty of Dentistry, Istinye Univeristy, İstanbul, Turkey
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio, USA
| | - Marta Revilla-León
- Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA
- Kois Center, University of Washington, Seattle, Washington, USA
- Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Massachusetts, USA
| |
Collapse
|
15
|
Revilla-León M, Lanis A, Yilmaz B, Kois JC, Gallucci GO. Intraoral digital implant scans: Parameters to improve accuracy. J Prosthodont 2023; 32:150-164. [PMID: 37586762 DOI: 10.1111/jopr.13749] [Citation(s) in RCA: 10] [Impact Index Per Article: 10.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/02/2023] [Accepted: 07/06/2023] [Indexed: 08/18/2023] Open
Abstract
PURPOSE To report the means to maximize the predictability and accuracy of intraoral digital implant scans through the evaluation of operator and patient-related factors. MATERIALS AND METHODS A search of published articles related to factors that can decrease the scanning accuracy of intraoral digital implant scans was completed in four data sources:MEDLINE, EMBASE, EBSCO, and Web of Science. All studies related to variables that can influence the accuracy of intraoral digital implant scans obtained by using intraoral scanners (IOSs) were considered. These variables included ambient lighting, scanning pattern, implant scan body (ISB) design, techniques for splinting ISBs, arch location, implant position, and inter-implant distance. RESULTS Among operator-related factors, ambient lighting conditions, scanning pattern, and ISB design (material, geometry, and retention design) can impact the accuracy of intraoral digital implant scans. The optimal ISB for maximizing IOS accuracy is unclear; however, polymer ISB can wear with multiple reuse and sterilization methods. Among patient-related factors, additional variables should be considered, namely arch (maxillary vs. mandibular arch), implant position in the arch, inter-implant distance, implant depth, and angulation. CONCLUSIONS Ambient lighting conditions should be established based on the IOS selected to optimize the accuracy of intraoral digital implant scans. The optimal scanning pattern may vary based on the IOS, clinical situation, and the number of implants. The optimal ISB design may vary depending on the IOS used. Metallic implant scan bodies are preferred over polymer ISB designs to minimize wear due to multiple use and sterilization distortion. Among patient-related factors, additional variables should be considered namely the arch scanned, implant position in the arch, inter-implant distance, implant depth, and angulation. The impact of these factors may vary depending on the IOS selected.
Collapse
Affiliation(s)
- Marta Revilla-León
- Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA
- Kois Center, Seattle, Washington, USA
- Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Massachusetts, USA
| | - Alejandro Lanis
- Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, Bern, Switzerland
- Department of Restorative, Preventive and Pediatric Dentistry, School of Dental Medicine, University of Bern, Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, Ohio, USA
| | - John C Kois
- Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA
- Kois Center, Seattle, Washington, USA
- Private Practice, Seattle, Washington, USA
| | - German O Gallucci
- Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA
| |
Collapse
|
16
|
Ashraf Y, Abo El Fadl A, Hamdy A, Ebeid K. Effect of different intraoral scanners and scanbody splinting on accuracy of scanning implant-supported full arch fixed prosthesis. J ESTHET RESTOR DENT 2023; 35:1257-1263. [PMID: 37310208 DOI: 10.1111/jerd.13070] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2023] [Revised: 05/30/2023] [Accepted: 05/31/2023] [Indexed: 06/14/2023]
Abstract
OBJECTIVE This study evaluated the accuracy of different intraoral scanners (IOS) for scanning of implant-supported full arch fixed prosthesis with different implant angulations with and without scanbodies splinting. MATERIALS AND METHODS Two maxillary models were designed and fabricated to receive an all-on-four implant retained. The models were divided into two groups according to the angulation of the posterior implant (Group 1; 30 and Group 2; 45). Each group was then divided into three subgroups according to the type of IOS used: Subgroup C; Primescan, subgroup T; Trios4, and subgroup M; Medit i600. Then each subgroup was divided into two divisions according to scanning technique; division S: splinted and division N: nonsplinted. Ten scans were made by each scanner for every division. Trueness and precision were analyzed using Geomagic controlX analysis software. RESULTS Angulation had no significant effect on both the trueness (p = 0.854) and precision (p = 0.347). Splinting had a significant effect on trueness and precision (p < 0.001). Scanner type had a significant effect on trueness (p < 0.001) and precision (p < 0.001). There was no significant difference between trueness of Trios 4 (112.15 ± 12.85) and Primescan (106.75 ± 22.58). However, there was a significant difference when compared to trueness of Medit i600 (158.50 ± 27.65). For the precision results Cerec Primescan showed the highest precision (95.45 ± 33.21). There was a significant difference between the three scanners, precision of Trios4 (109.72 ± 19.24) and Medit i600 (121.21 ± 17.26). CONCLUSION Cerec Primescan has higher trueness and precision than Trios 4 and Medit i600 in full arch implants scanning. Splinting the scanbodies improve the accuracy of full arch implants scanning. CLINICAL SIGNIFICANCE Cerec Primescan and 3Shape Trios 4 can be used for scanning of All-on-four implant supported prosthesis when scanbodies are splinted using a modular chain device.
Collapse
Affiliation(s)
- Yasmine Ashraf
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Ahmad Abo El Fadl
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Amina Hamdy
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Kamal Ebeid
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| |
Collapse
|
17
|
Talesara V, Bennani V, Aarts J, Ratnayake J, Khurshid Z, Brunton P. Accuracy of digitally coded healing abutments: A systematic review. Saudi Dent J 2023; 35:891-903. [PMID: 38107040 PMCID: PMC10724348 DOI: 10.1016/j.sdentj.2023.08.006] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Revised: 08/10/2023] [Accepted: 08/13/2023] [Indexed: 12/19/2023] Open
Abstract
The aim of this systematic review was to evaluate the in vitro accuracy of dental implant impressions taken using digitally coded healing abutments (CHAs) compared with impressions taken with conventional techniques (CI) and/or within the CHA group at varying degrees of angulations for multiple implant units. Two independent reviewers conducted a systematic electronic search in the MedLine, PubMed, Google Scholar, Cochrane Library, Web of Science, and Scopus databases. Some of the employed key terms, combined with the help of Boolean operators, were: "digitally coded healing abutments", "encode healing abutment", "dental implants", "impression accuracy", "digital impression", and "conventional impression". Publication dates ranged from January 2010 to November 2022. A total of 7 articles fulfilled the inclusion criteria: 6 studies compared the accuracy of CHA with conventional pick-up impression techniques, and one study only used CHAs at different angulations and heights to compare accuracy within the group. The results were divided into Group A (elastomeric impression of CHA) and Group B (CHA + Intraoral scanner). According to the results of this systematic review, elastomeric impression of CHA performed poorly when compared to CI for multiple implants, although an intraoral scan of CHA appears to be more accurate. Within the CHA group, the angulation and visible height of CHA play a significant role in impression accuracy. However, more studies are needed before CHA can be recommended for all non-parallel multiple implant-supported restorations.
Collapse
Affiliation(s)
- Vaibhav Talesara
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, Dunedin 9016, New Zealand
| | - Vincent Bennani
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, Dunedin 9016, New Zealand
| | - John Aarts
- Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, Dunedin 9016, New Zealand
| | - Jithendra Ratnayake
- Department of Oral Science, Faculty of Dentistry, University of Otago, Dunedin 9016, New Zealand
| | - Zohaib Khurshid
- Department of Prosthodontics and Dental Implantology, College of Dentistry, King Faisal University, Saudi Arabia
| | | |
Collapse
|
18
|
Gómez-Polo M, Barmak AB, Ortega R, Rutkunas V, Kois JC, Revilla-León M. Accuracy, scanning time, and patient satisfaction of stereophotogrammetry systems for acquiring 3D dental implant positions: A systematic review. J Prosthodont 2023; 32:208-224. [PMID: 37591510 DOI: 10.1111/jopr.13751] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2023] [Revised: 06/17/2023] [Accepted: 06/25/2023] [Indexed: 08/19/2023] Open
Abstract
PURPOSE To evaluate accuracy, scanning time, and patient satisfaction of photogrammetry (PG) systems for recording the 3D position of dental implants. MATERIAL AND METHODS A literature search was completed in five databases: PubMed/Medline, Scopus, Embase, World of Science, and Cochrane. A manual search was also conducted. Studies reporting the use of commercially available PG systems were included. Two investigators evaluated the studies independently by applying the Joanna Briggs Institute critical appraisal. A third examiner was consulted to resolve any lack of consensus. RESULTS A total of 14 articles were included: 3 in vivo, 6 in vitro, and 6 case report manuscripts. One clinical study evaluated trueness, another one tested precision, and the third one assessed impression time and patient and operator satisfaction. All the in vitro studies evaluated the trueness and precision of a PG system. Additionally, all the reviewed studies investigated completely edentulous conditions with multiple implants. The number of placed implants per arch among the reviewed clinical studies varied from 4 to 8 implants, while the number of implants placed on the reference casts included 4, 5, 6, or 8 implants. Not all the studies compared the accuracy of PG systems with conventional impression methods, using intraoral scanners as additional experimental groups. For the PIC system, trueness ranged from 10 to 49 μm and precision ranged from 5 to 65 μm. For the iCam4D system, trueness ranged from 24 to 77 μm and the precision value ranged from 2 to 203 μm. CONCLUSIONS PG systems may provide a reliable alternative for acquiring the 3D position of dental implants. However, this conclusion should be interpreted carefully, as one study reported a mean precision value of one PG system higher than the clinically acceptable discrepancy. Lower scanning time and higher patient and operator satisfaction have been reported when compared with conventional techniques. Further studies are needed to increase the evidence regarding the accuracy, scanning time, and patient and operator satisfaction of the commercially available PG systems.
Collapse
Affiliation(s)
- Miguel Gómez-Polo
- Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain
| | - Abdul B Barmak
- Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, New York, USA
| | - Rocío Ortega
- Department of Prosthetic Dentistry, School of Dentistry, European University of Madrid, Madrid, Spain
| | - Vygandas Rutkunas
- Digitorum Research Center, Vilnius, Lithuania
- Department of Prosthodontics, Institute of Odontology, Faculty of Medicine, Vilnius University, Vilnius, Lithuania
| | - John C Kois
- Kois Center, Seattle, Washington, USA
- Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA
- Private Practice, Seattle, Washington, USA
| | - Marta Revilla-León
- Kois Center, Seattle, Washington, USA
- Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA
- Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Massachusetts, USA
| |
Collapse
|
19
|
De Rubertis C, Ferrante F, Stefanelli N, Friuli M, Madaghiele M, Demitri C, Palermo A. The accuracy of intra-oral scanners in full arch implant rehabilitation: a narrative review. Br Dent J 2023; 235:887-891. [PMID: 38066152 DOI: 10.1038/s41415-023-6550-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2022] [Revised: 05/24/2023] [Accepted: 05/29/2023] [Indexed: 12/18/2023]
Abstract
This narrative review aims to study the accuracy of different intra-oral scanner (IOS) devices already available on the market. The accuracy emerged during in vitro, in vivo and ex vivo studies made with IOS devices during the scan of a full arch implant rehabilitation that have been analysed to evaluate which device may be the most suitable in this clinical situation. The literature review was performed by searching topics and keywords using the PubMed and Medline databases, for example, 'digital workflow', 'full arch', 'full arch implant rehabilitation' and 'accuracy of IOS'. Inclusion and exclusion criteria for studies were: correct IMRAD (introduction, methods, results and discussion) structure; article with clear and detailed objectives; consistency of the articles with the purpose of the review; two-year range from the year of publication of the article; reproducible materials and methods; and correct follow-up. Most of the intra-oral scanners employed in vitro provided acceptable accuracy (below a threshold of 150 μm). The main parameters identified for their influence on precision were interim plant distance, body scan design, scanning pattern and operator experience. Even though literature is limited, significant differences emerged between the different models of intra-oral scanners evaluated in the studies considered within this review.
Collapse
Affiliation(s)
| | - Franco Ferrante
- Specialist in Oral Surgery, Private Practitioner, Lecce, Italy
| | | | - Marco Friuli
- Department of Engineering for Innovation, University of Salento, Lecce 73100, Italy.
| | - Marta Madaghiele
- Department of Engineering for Innovation, University of Salento, Lecce 73100, Italy
| | - Christian Demitri
- Department of Engineering for Innovation, University of Salento, Lecce 73100, Italy
| | - Andrea Palermo
- College of Medicine and Dentistry, Birmingham, B4 6BN, United Kingdom
| |
Collapse
|
20
|
Pachiou A, Zervou E, Tsirogiannis P, Sykaras N, Tortopidis D, Kourtis S. Characteristics of intraoral scan bodies and their influence on impression accuracy: A systematic review. J ESTHET RESTOR DENT 2023; 35:1205-1217. [PMID: 37381677 DOI: 10.1111/jerd.13074] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2023] [Revised: 06/07/2023] [Accepted: 06/08/2023] [Indexed: 06/30/2023]
Abstract
OBJECTIVE The aim of this systematic review was to evaluate the influence of the characteristics of intraoral scan bodies (ISBs) on the accuracy of intraoral scanning. MATERIALS AND METHODS An electronic search was conducted through PubMed (MEDLINE), Scopus and Cochrane Library, up to March 2023. The literature search intended to retrieve all relevant clinical and in vitro studies about the effect that the various properties of ISBs may have on the accuracy (trueness and precision) of intraoral scanning. Only publications in English language were selected with animal studies, case reports, case series, technique presentation articles and expert opinions being excluded. RESULTS A total of 28 studies met the inclusion criteria and were included in this systematic review. They were published between 2019 and 2023 and were all in vitro studies. Among the parameters described, the scan body material, position, geometry, height, diameter, and fixation torque were evaluated. The most common materials used for ISBs were polyetheretherketone (PEEK) and titanium alloys. The diameter and position of ISBs seemed to affect the trueness of implant impressions. Subgingival implant position and decreased ISB height affected negatively the trueness of scanning. Geometrical characteristics of ISBs also affect the implant impression accuracy, especially the bevel location and the types of designing modifications. CONCLUSIONS The characteristics of the currently used ISBs vary widely and the available scientific evidence is not yet conclusive about the optimal design of ISB. The implant impression accuracy achieved by any of the studied parameters is encouraging. Clinical studies are however necessary for more concrete conclusions. CLINICAL SIGNIFICANCE ISBs play a vital role in the digital workflow and influence significantly the accuracy and fit of implant restorations. More clinical trials are needed in order to conclude to the optimal characteristics of ISBs which would further enhance the success of the restorations.
Collapse
Affiliation(s)
- Aspasia Pachiou
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Evangelia Zervou
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Panagiotis Tsirogiannis
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Nikitas Sykaras
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| | - Dimitrios Tortopidis
- Department of Prosthodontics, School of Dentistry, Aristotle University of Thessaloniki, Thessaloniki, Greece
| | - Stefanos Kourtis
- Department of Prosthodontics, School of Dentistry, National and Kapodistrian University of Athens, Athens, Greece
| |
Collapse
|
21
|
Hardan L, Bourgi R, Lukomska-Szymanska M, Hernández-Cabanillas JC, Zamarripa-Calderón JE, Jorquera G, Ghishan S, Cuevas-Suárez CE. Effect of scanning strategies on the accuracy of digital intraoral scanners: a meta-analysis of in vitro studies. J Adv Prosthodont 2023; 15:315-332. [PMID: 38205120 PMCID: PMC10774636 DOI: 10.4047/jap.2023.15.6.315] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 11/28/2023] [Accepted: 12/15/2023] [Indexed: 01/12/2024] Open
Abstract
PURPOSE This study aimed to investigate whether the accuracy of intraoral scanners is influenced by different scanning strategies in an in vitro setting, through a systematic review and meta-analysis. MATERIALS AND METHODS This review was conducted in accordance with the PRISMA 2020 standard. The following PICOS approach was used: population, tooth impressions; intervention, the use of intraoral scanners with scanning strategies different from the manufacturer's instructions; control, the use of intraoral scanners following the manufacturers' requirements; outcome, accuracy of intraoral scanners; type of studies, in vitro. A comprehensive literature search was conducted across various databases including Embase, SciELO, PubMed, Scopus, and Web of Science. The inclusion criteria were based on in vitro studies that reported the accuracy of digital impressions using intraoral scanners. Analysis was performed using Review Manager software (version 5.3.5; Cochrane Collaboration, Copenhagen, Denmark). Global comparisons were made using a standardized mean difference based on random-effect models, with a significance level of α = 0.05. RESULTS The meta-analysis included 15 articles. Digital impression accuracy significantly improved under dry conditions (P < 0.001). Moreover, trueness and precision were enhanced when artificial landmarks were used (P ≤ 0.02) and when an S-shaped pattern was followed (P ≤ 0.01). However, the type of light used did not have a significant impact on the accuracy of the digital intraoral scanners (P ≥ 0.16). CONCLUSION The accuracy of digital intraoral scanners can be enhanced by employing scanning processes using artificial landmarks and digital impressions under dry conditions.
Collapse
Affiliation(s)
- Louis Hardan
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut, Lebanon
| | - Rim Bourgi
- Department of Restorative Dentistry, School of Dentistry, Saint-Joseph University, Beirut, Lebanon
- Department of Biomaterials and Bioengineering, INSERM UMR_S 1121, University of Strasbourg, Strasbourg, France
| | | | - Juan Carlos Hernández-Cabanillas
- Health Sciences Faculty, Autonomous University of Baja California, Blvd Universitario 1000 Valle de Las Palmas, Tijuana, B.C. Mexico
| | - Juan Eliezer Zamarripa-Calderón
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, San Agustín Tlaxiaca, Mexico
| | - Gilbert Jorquera
- Department of Prosthodontics, Universidad de los Andes, Santiago, Chile
| | | | - Carlos Enrique Cuevas-Suárez
- Dental Materials Laboratory, Academic Area of Dentistry, Autonomous University of Hidalgo State, San Agustín Tlaxiaca, Mexico
| |
Collapse
|
22
|
El Ebiary SO, Atef M, Abdelaziz MS, Khashaba M. Guided immediate implant with and without using a mixture of autogenous and xeno bone grafts in the dental esthetic zone. A randomized clinical trial. BMC Res Notes 2023; 16:331. [PMID: 37957760 PMCID: PMC10644537 DOI: 10.1186/s13104-023-06612-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2023] [Accepted: 11/03/2023] [Indexed: 11/15/2023] Open
Abstract
PURPOSE This in vivo study aims to assess the pink esthetic score in the anterior maxilla after computer-guided immediate implant installation and fully digital immediate temporalization with and without grafting the jumping gap with a mixture of 1:1 autogenous and xenograft particulates. MATERIALS AND METHODS Twenty-four patients with non-restorable upper anterior teeth in the aesthetic zone have undergone a traumatic extraction for the non-restorable tooth followed by immediate implant placement using a 3D-printed surgical guide according to prosthetically driven implant placement. The patients were divided into two groups. The study group received the dental implant after grafting the jumping gap with 1:1 autogenous and xenograft particulates, while the control group received the dental implant without grafting the jumping gap. Each patient received a digitally fabricated, immediate, nonfunctional temporary prosthesis. The esthetic outcome was compared between the two groups using the pink esthetic score at implant insertion and after 6 months of follow-up. Statistical comparisons were carried out between the studied groups using the Mann-Whitney U test. RESULTS Immediately postoperatively, there was no statistically significant difference between the median PES in the two groups (P-value = 0.746). After six months, the study group showed a statistically significantly higher median PES than the control group (P-value = 0.048). CONCLUSIONS Grafting the jumping distance in the immediate implant protocol helps achieve a better esthetic outcome. CLINICAL RELEVANCE The use of immediate guided implant placement along with grafting the jumping gap followed by immediate digital temporalization guarantees a better esthetic outcome while preserving time, cost, and the number of clinical visits. TRIAL REGISTRATION The study was registered on clinicaltrials.gov with registration number NCT04096209. (19/9/2019).
Collapse
Affiliation(s)
- Sherine Osama El Ebiary
- Department of Prosthodontics, Faculty of Oral and Dental Medicine, Cairo University, Giza, Egypt
| | - Mohammed Atef
- Department of Oral and Maxillofacial Surgery, Faculty of Oral and Dental Medicine, Cairo University, Giza, Egypt
| | - Medhat Sameh Abdelaziz
- Department of Prosthodontics, Faculty of Oral and Dental Medicine, Future University in Egypt, Fifth Settlement, End of 90 street, New Cairo, Cairo, Egypt.
| | - Mohammed Khashaba
- Department of Oral and Maxillofacial Surgery, Faculty of Oral and Dental Medicine, Cairo University, Giza, Egypt
| |
Collapse
|
23
|
Wu HK, Chen G, Huang X, Deng F, Li Y. Accuracy of single-implant digital impression with various scanbody exposure levels at anterior and posterior regions. J Dent 2023; 138:104641. [PMID: 37516339 DOI: 10.1016/j.jdent.2023.104641] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2023] [Revised: 07/25/2023] [Accepted: 07/27/2023] [Indexed: 07/31/2023] Open
Abstract
OBJECTIVES This in vitro study aimed to evaluate the effect of the exposure heights of the scanbody on the accuracy of digital implant impressions at different positions. METHODS Four maxillary master models with one analog at the anterior and posterior region were fabricated by a 3-dimensional (3D) printer. The analogs were submerged from the gingival margin to ensure four exposure heights of the scanbody: 10, 8, 6, and 4 mm. . The master models were then scanned with D2000 dental laboratory scanner as the reference models. An intraoral scanner obtained ten test models for each group. After aligning the scanbody library file, the related files were imported into inspection software for superimposition by a local fit algorithm based on the adjacent teeth. RESULTS 3D trueness was significantly decreased at 6 and 4 mm scanbody exposure at the anterior region. In comparison, a significant decrease was only seen at 4 mm scanbody exposure at the posterior region. 3D precision was significantly decreased at 4 mm scanbody exposure at both anterior and posterior regions. CONCLUSION The exposure height of the scanbody influenced the accuracy of the digital implant impression, according to the implant positions. Scanbody exposure of less than 6 mm at the anterior region and 4 mm scanbody exposure at the posterior region could lead to increased deviations, but still in the tolerance range. CLINICAL SIGNIFICANCE The scanbody exposure height less than 6 mm at the anterior region and 4 mm scanbody exposure height at the posterior region could lead to significantly increased deviations. Though these deviations may be still in the clinically acceptable range, caution should be taken.
Collapse
Affiliation(s)
- Hio Kuan Wu
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China
| | - Guanhui Chen
- Department of Stomatology, The Seventh Affiliated Hospital, Sun Yat-Sen University, Shenzhen, Guangdong 518107, China
| | - Xiaoqiong Huang
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China
| | - Feilong Deng
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China.
| | - Yiming Li
- Hospital of Stomatology, Guanghua School of Stomatology, Sun Yat-Sen University, Guangdong Provincial Key Laboratory of Stomatology, Guangzhou 510055, China.
| |
Collapse
|
24
|
Revilla-León M, Gohil A, Barmak AB, Gómez-Polo M, Pérez-Barquero JA, Att W, Kois JC. Influence of ambient temperature changes on intraoral scanning accuracy. J Prosthet Dent 2023; 130:755-760. [PMID: 35210107 DOI: 10.1016/j.prosdent.2022.01.012] [Citation(s) in RCA: 53] [Impact Index Per Article: 53.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/28/2021] [Revised: 12/31/2021] [Accepted: 01/04/2022] [Indexed: 11/20/2022]
Abstract
STATEMENT OF PROBLEM Different variables that decrease the accuracy of intraoral scanners (IOSs) have been identified. Ambient temperature changes can occur in the dental environment, but the impact of ambient temperature changes on intraoral scanning accuracy is unknown. PURPOSE The purpose of this in vitro study was to assess the impact of ambient temperature changes on the accuracy (trueness and precision) of an IOS. MATERIAL AND METHODS A complete arch maxillary dentate Type IV stone cast was obtained. Four 6-mm-diameter gauge balls were added to the maxillary cast to aid future evaluation measurements. The maxillary cast was digitized by using an industrial scanner (GOM Atos Q 3D 12M). The manufacturer's recommendations were followed in obtaining a reference scan. Then, the maxillary cast was digitized by using an IOS (TRIOS 4) according to the scanning protocol recommended by the manufacturer. Four groups were created depending on the ambient temperature change assessed: 24 °C or room temperature (24-D or control group), 19 °C or a 5-degree temperature drop (19-D group), 15 °C or a 9-degree temperature drop (15-D group), and 29 °C or a 5-degree temperature rise (29-D group). The Shapiro-Wilk and Kolmogorov-Smirnov tests revealed that the data were not normally distributed (P<.05). For trueness, the nonparametric Kruskal-Wallis followed by the Dwass-Steel-Critchlow-Fligner pairwise comparison tests were used. Precision analysis was obtained by using the Levene test based on the comparison of the standard deviations of the 4 groups with 95% Bonferroni confidence intervals for standard deviations (α=.05). RESULTS The Kruskal-Wallis test revealed significant differences in the trueness values among all 4 groups (P<.001). Furthermore, significant differences between the linear discrepancy medians between the control and 19-D groups (P<.001), control and 15-D groups (P=.002), control and 29-D groups (P<.001), 19-D and 29-D groups (P=.003), and 15-D and 29-D groups (P<.001) were found. The Levene test for the comparison of the variances among the 4 groups did not detect a significant difference (P>.999), indicating that precision wise the 4 groups were not significantly different from each other. CONCLUSIONS Ambient temperature changes had a detrimental effect on the accuracy (trueness and precision) of the IOS tested. Ambient temperature changes significantly decreased the scanning accuracy of the IOS system tested. Increasing the ambient temperature has a greater influence on the intraoral scanning accuracy of the IOS selected when compared with decreasing the ambient temperature.
Collapse
Affiliation(s)
- Marta Revilla-León
- Affiliate Assistant Professor Graduate Prosthodontics, Department of Restorative Dentistry, School of Density, University of Washington, Seattle, Wash; Director of Research and Digital Dentistry, Kois Center, Seattle, Wash; Adjunct Professor Graduate Prosthodontics, Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, Mass.
| | - Aishwa Gohil
- Predoctoral student, College of Dentistry, Texas A&M University, Dallas, Texas
| | - Abdul B Barmak
- Assistant Professor Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY
| | - Miguel Gómez-Polo
- Associate Professor, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain
| | - Jorge Alonso Pérez-Barquero
- Associate Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | - Wael Att
- Professor and Chair Department of Prosthodontics, Tuff University School of Dental Medicine, Boston, Mass
| | - John C Kois
- Founder and Director, Kois Center, Seattle, Wash; Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Private practice, Seattle, Wash
| |
Collapse
|
25
|
Shely A, Lugassy D, Rosner O, Zanziper E, Nissan J, Rachmiel S, Khoury Y, Ben-Izhack G. The Influence of Laboratory Scanner versus Intra-Oral Scanner on Determining Axes and Distances between Three Implants in a Straight Line by Using Two Different Intraoral Scan Bodies: A Pilot In Vitro Study. J Clin Med 2023; 12:6644. [PMID: 37892783 PMCID: PMC10607023 DOI: 10.3390/jcm12206644] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 10/13/2023] [Accepted: 10/18/2023] [Indexed: 10/29/2023] Open
Abstract
BACKGROUND The purpose of this in vitro study was to compare the inter-implant distance, inter-implant axis, and intra-implant axis of three implants in a straight line by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS) with two different intra-oral scan bodies (ISBs). METHODS A 3D model was printed with internal hex implant analogs of three implants in positions 15#, 16#, and 17#. Two standard intra-oral scan bodies (ISBs) were used: MIS ISB (two-piece titanium) and Zirkonzhan ISB (two-piece titanium). Both ISBs were scanned using 7 Series dental wings (LBS) and 30 times using Primescan (IOS). For each scan, a stereolithography (STL) file was created and a comparison between all the scans was performed through superimposition of the STL files by using 3D analysis software (PolyWorks® 2020; InnovMetric, Québec, QC, Canada). A Kolmogorov-Smirnov test was performed followed by a Mann-Whitney test (p < 0.05). RESULTS The change in inter-implant distance for the MIS ISB was significantly lower compared to the ZZ (p < 0.05). The change in intra-implant angle was significantly lower for the ZZ ISB compared to MIS (p < 0.05). The changes in inter-implant angle between the mesial and middle and between the middle and distal were significantly lower for MIS compared to ZZ in contrast to mesial to distal, which was significantly higher (p < 0.05). CONCLUSIONS Both ISBs showed differences in all the parameters between the LBS and the IOS. The geometry of the scan abutment had an impact on the inter-implant distance as the changes in the inter-implant distance were significantly lower for the MIS ISB. The changes in the intra-implant angle were significantly lower for the ZZ ISB. There is a need for further research examining the influence of geometry, material, and scan abutment parts on the trueness.
Collapse
Affiliation(s)
- Asaf Shely
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (A.S.); (O.R.); (E.Z.); (J.N.); (S.R.); (Y.K.)
| | - Diva Lugassy
- Department of Orthodontics, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel;
| | - Ophir Rosner
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (A.S.); (O.R.); (E.Z.); (J.N.); (S.R.); (Y.K.)
| | - Eran Zanziper
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (A.S.); (O.R.); (E.Z.); (J.N.); (S.R.); (Y.K.)
| | - Joseph Nissan
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (A.S.); (O.R.); (E.Z.); (J.N.); (S.R.); (Y.K.)
| | - Shir Rachmiel
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (A.S.); (O.R.); (E.Z.); (J.N.); (S.R.); (Y.K.)
| | - Yara Khoury
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (A.S.); (O.R.); (E.Z.); (J.N.); (S.R.); (Y.K.)
| | - Gil Ben-Izhack
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (A.S.); (O.R.); (E.Z.); (J.N.); (S.R.); (Y.K.)
| |
Collapse
|
26
|
Pozzi A, Carosi P, Gallucci GO, Nagy K, Nardi A, Arcuri L. Accuracy of complete-arch digital implant impression with intraoral optical scanning and stereophotogrammetry: An in vivo prospective comparative study. Clin Oral Implants Res 2023; 34:1106-1117. [PMID: 37485737 DOI: 10.1111/clr.14141] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/11/2023] [Revised: 07/04/2023] [Accepted: 07/13/2023] [Indexed: 07/25/2023]
Abstract
OBJECTIVES To assess accuracy of intraoral optical scanning (IOS) and stereophotogrammetry (SPG), complete-arch digital implant impressions in vivo. MATERIALS AND METHODS Consecutive patients needing implant-supported screw-retained zirconia complete-arch fixed-dental prostheses (ISZ-FDP) were recruited. For each patient, three impressions were taken: IOS, SPG (tests), and open-tray plaster (reference). Linear (ΔX, ΔY, and ΔZ), three-dimensional (ΔEUC), and angular deviations (ΔANGLE) were evaluated and stratified according to scanning technology for each implant. Potential effects of impression device (IOS and SPG), arch (maxilla and mandible), and implant number (4 and 6) were evaluated through multivariable analysis. Significance level was set at .05. RESULTS A total of 11 complete arches (5 maxillae, 6 mandibles) in 11 patients were rehabilitated with ISZ-FDPs supported by 4 (n = 8) and 6 implants (n = 3). A total of 50 implants and 100 implant positions were captured by two investigated devices and compared to respective reference (mean ΔEUC IOS 137.2, SPG 87.6 μm; mean ΔANGLE 0.79, 0.38°). Differences between measurements (SPG-IOS) were computed for each implant, with negative values indicating better SPG accuracy. Significant mean ΔEUC difference of -49.60 μm (p = .0143; SD 138.15) and mean ΔANGLE difference of -0.40° (p < .0001; SD 0.65) were observed in favor of SPG. Multivariable analysis showed significant effect on ΔEUC (p = .0162) and ΔANGLE (p = .0001) only for impression devices, with SPG performing better. CONCLUSIONS SPG experienced significantly higher linear and angular accuracy. No effect of type of arch or implant number was detected. Higher extreme deviations were experienced for IOS. SPG can be feasible for complete-arch digital impressions with caution, and rigid prototype try-in is recommended before screw-retained prosthesis manufacturing.
Collapse
Affiliation(s)
- Alessandro Pozzi
- Department of Clinical Sciences and Translational Medicine, School of Dentistry, University of Tor Vergata, Rome, Italy
- Departement of Restorative Sciences, Dental College of Georgia, Augusta University, Augusta, USA
| | - Paolo Carosi
- Department of Chemical Science and Technologies, PhD in Materials for Health, Environment and Energy - Dentistry, University of Rome Tor Vergata, Rome, Italy
| | - German O Gallucci
- Department of Restorative Dentistry and Biomaterials Sciences, Harvard School of Dental Medicine, Boston, Massachusetts, USA
| | - Katalin Nagy
- Department of Oral Surgery, Faculty of Dentistry, University of Szeged Tisza L. Krt, Szeged, Hungary
| | - Alessandra Nardi
- Department of Mathematics, University of Rome Tor Vergata, Rome, Italy
| | - Lorenzo Arcuri
- Department of Odontostomatological and Maxillofacial Sciences, Sapienza University of Rome, Rome, Italy
| |
Collapse
|
27
|
Yan Y, Lin X, Yue X, Geng W. Accuracy of 2 direct digital scanning techniques-intraoral scanning and stereophotogrammetry-for complete arch implant-supported fixed prostheses: A prospective study. J Prosthet Dent 2023; 130:564-572. [PMID: 35667889 DOI: 10.1016/j.prosdent.2022.03.033] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 03/01/2022] [Accepted: 03/02/2022] [Indexed: 10/18/2022]
Abstract
STATEMENT OF PROBLEM Conventional impression techniques for complete arch implant-supported prostheses are technique-sensitive. Stereophotogrammetry (SPG) and intraoral scanning (IOS) may offer an alternative to conventional impression making. PURPOSE The purpose of this prospective study was to compare the accuracy of IOS and SPG for complete arch implant scans and to evaluate the passive fit of frameworks fabricated with SPG. MATERIAL AND METHODS Laboratory scanning of gypsum casts, SPG, and IOS were performed for all participants. The data regarding the abutment platform were superimposed to calculate the 3D deviation of SPG and IOS compared with that of laboratory scanning as an evaluation of accuracy. The effect of implant position and number on accuracy was analyzed. The more accurate technique between SPG and IOS was used to fabricate the titanium frameworks, as was laboratory scanning. The passive fit of the frameworks was assessed by clinical examination, the Sheffield test, and panoramic radiography. RESULTS Seventeen participants (21 arches, 120 implants) were included. The accuracy of SPG ranged from 2.70 μm to 92.80 μm, with a median (Q1, Q3) of 17.00 (11.68, 22.50) μm, which was significantly more accurate than that of IOS, ranging from 21.30 μm to 815.60 μm, with a median (Q1, Q3) of 48.95 (34.78, 75.88) μm. No significant correlation was found between position or number of implants and 3D deviation in the SPG group. A weak positive correlation was found between implant number and 3D deviation in the IOS group. SPG and laboratory scanning were used to fabricate titanium frameworks. The passive fit between the frameworks and abutment platforms was confirmed. CONCLUSIONS SPG, which was not affected by position or number of implants, was more accurate than IOS and comparable with laboratory scanning. The frameworks fabricated based on SPG and laboratory scanning were comparable in their passive fit. The SPG technique may be an alternative to laboratory scanning for complete arch implant scans.
Collapse
Affiliation(s)
- Yuwei Yan
- Graduate student, Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing, PR China
| | - Xiao Lin
- Attending physician, Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing, PR China
| | - Xinxin Yue
- Attending physician, Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing, PR China
| | - Wei Geng
- Professor, Department of Dental Implant Center, Beijing Stomatological Hospital, School of Stomatology, Capital Medical University, Beijing, PR China.
| |
Collapse
|
28
|
Gómez-Polo M, Immorlano MG, Cascos-Sánchez R, Ortega R, Barmak AB, Kois JC, Revilla-León M. Influence of the dental arch and number of cutting-off and rescanning mesh holes on the accuracy of implant scans in partially edentulous situations. J Dent 2023; 137:104667. [PMID: 37595865 DOI: 10.1016/j.jdent.2023.104667] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/23/2022] [Revised: 08/03/2023] [Accepted: 08/16/2023] [Indexed: 08/20/2023] Open
Abstract
OBJECTIVES To evaluate the influence of the dental arch and cutting-off and rescanning procedures on the accuracy of complete-arch implant scans in partially edentulous arches. MATERIAL AND METHODS A maxillary and a mandibular partially edentulous typodont with implant abutment analogs placed in the right and left first molar and right central incisor sites were digitized to create reference models by using an industrial optical scanner (7 Series Desktop Scanner; Dentalwings). Two experimental groups were scanned using an intraoral scanner (IOS) (TRIOS 4; 3Shape A/S): the Maxillary group (Mx) and the Mandibular group (Mb). Four subgroups were generated depending on the number of rescanned mesh holes: No holes (Mx-G0, Mb-G0), 1 hole (Mx-G1, Mb-G1), 2 holes (Mx-G2, Mb-G2) and 3 holes (Mx-G3, Mb-G3). A 3-dimensional metrology software (Geomagic Control X; 3D Systems) was used to measure the difference between the reference and the experimental scans computing the root mean square (RMS) error calculation. Two-way ANOVA and a post-hoc Tukey test were used to analyze the trueness data (α=0.05). Levene test was used to evaluate the prevision (α=0.05). RESULTS The Mx group obtained a trueness mean value of 54 ± 17 µm and a mean precision value of 54 ± 17 µm, while the Mb group presented a trueness mean value of 67 ± 23 µm and a mean precision value of 66 ± 22 µm. The Mx group demonstrated significantly better trueness than the Mb group (P<.001). The G0 and G1 subgroups had the highest trueness values among the subgroups tested. No significant difference was observed between G0 and G1, G1 and G2, and G2 and G3 subgroups in trueness and precision. However, the G0 had significantly better trueness and precision values compared to G2 and G3 subgroups. In addition, the G1 had significantly better trueness values than the G3 subgroup. However, the Levene test revealed no difference in the precision mean values among the subgroups tested. CONCLUSIONS Implant scanning trueness was affected by the dental arch and the number of rescanned mesh holes using the IOS tested. A higher number of rescanned mesh holes decreased the scanning trueness. The stitching algorithm of the IOS software tested after the mesh hole scan demonstrated a significant error, especially when multiples mesh holes are involved in the same arch. CLINICAL SIGNIFICANCE Given that cutting-off and rescanning techniques can reduce trueness, clinicians should consider whether these techniques are necessary in complete digital workflows. This is particularly important when fabricating multiple single implant-supported restorations in the same arch.
Collapse
Affiliation(s)
- Miguel Gómez-Polo
- Associate Professor Department of Conservative Dentistry and Prosthodontics, Director of postgraduate program of Advanced in Implant-Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain.
| | - Marina García Immorlano
- Postgraduate Specialist in Advanced-Prosthodontics. Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain
| | - Rocío Cascos-Sánchez
- Postgraduate Specialist in Advanced in Implant-Prosthodontics, Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain
| | - Rocío Ortega
- Adjunct Professor Department of Prosthetic Dentistry, School of Dentistry, European University of Madrid, Madrid, Spain
| | - Abdul B Barmak
- Assistant Professor Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY USA
| | - John C Kois
- Founder and Director Kois Center, Seattle, WA; Affiliate Professor, Graduate Prosthodontics, Department of Restorative Dentistry, University of Washington, Seattle, WA; and Private Practice, Seattle, WA USA
| | - Marta Revilla-León
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA; Faculty and Director of Research and Digital Dentistry, Kois Center, Seattle, WA; and Adjunct Professor, Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, MA USA
| |
Collapse
|
29
|
Hussein MO. Photogrammetry technology in implant dentistry: A systematic review. J Prosthet Dent 2023; 130:318-326. [PMID: 34801243 DOI: 10.1016/j.prosdent.2021.09.015] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2021] [Revised: 09/22/2021] [Accepted: 09/22/2021] [Indexed: 11/28/2022]
Abstract
STATEMENT OF PROBLEM Photogrammetry technology may be useful in implant dentistry, but a systematic review is lacking and is indicated before routine use in clinical practice. PURPOSE The purpose of this systematic review was to assess the role of the photogrammetry technology used in implant dentistry and determine its validity as an accurate tool with clinical applications. MATERIAL AND METHODS Four major databases, PubMed MEDLINE, Google Scholar, Scopus, and Web of Science, were selected to retrieve articles published from January 2011 to February 2021 based on custom criteria. The search was augmented by a manual search. After screening of the collected articles, data, including study design and setting, type of application, digitizer used, reference body, method of evaluation, and overall outcomes, were extracted. RESULTS Twenty articles were included based on the selection criteria. Most of the articles confirmed that the use of photogrammetry was promising as an implant coordinate transfer system. However, few articles showed its use for 3-dimensional scanning, which might require more development. CONCLUSIONS The initial reports of using photogrammetry technology considered this method as a valid and reliable clinical tool in implant dentistry. More studies to develop the photogrammetry technology and to assess the results with evidence-based research are recommended to enhance its application in different clinical situations.
Collapse
Affiliation(s)
- Mostafa Omran Hussein
- Associate Professor of Prosthodontics, Department of Prosthodontic Sciences, College of Dentistry in Ar Rass, Qassim University, El-Qassim, Saudi Arabia.
| |
Collapse
|
30
|
Emam NS, Khamis MM, Abdelhamid AM, Ezzelarab S. Digitization accuracy and scannability of different prosthodontic materials: An in vitro trial. J Prosthet Dent 2023; 130:252.e1-252.e8. [PMID: 37468368 DOI: 10.1016/j.prosdent.2023.05.032] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/19/2023] [Revised: 05/23/2023] [Accepted: 05/24/2023] [Indexed: 07/21/2023]
Abstract
STATEMENT OF PROBLEM Digital scanning of different prosthodontic materials is commonplace in contemporary practice. However, the scannability of prosthodontic materials has not been thoroughly investigated. PURPOSE The purpose of this in vitro study was to evaluate the scanning accuracy and measure the unscanned area in a preset time limit of commonly used framework materials. MATERIAL AND METHODS A mandibular acrylic resin reference dental typodont with 3 teeth, with the central one prepared for a complete coverage crown, was digitized by using a desktop scanner. A complete coverage crown was generated in standard tessellation language (STL) format. Three groups were created from the digital design according to the crown material: milled polyetheretherketone (PEEK), milled airborne-particle abraded titanium, and milled polymethylmethacrylate (PMMA). They were scanned with the desktop scanner to be used as reference files for each group. The intraoral scanner Medit i700 was used to digitize each specimen 10 times (n=10). Using a nonmetrology grade software program, the deviations between the test STL file of the intraoral scanner and the reference STL file of the desktop scanner were assessed by using the RMS values. The unscanned surface area in a preset time limit of 6 seconds (scannability) was assessed. Groups were compared by using 1-way ANOVA followed by the Tukey post hoc test with Bonferroni correction when the results were significant. All tests were 2-tailed (α=0.05). RESULTS Regarding deviation analysis, RMS discrepancies were computed, and significant differences in trueness were found (P<.001) among the 3 studied groups. The titanium group had the highest trueness followed by the PEEK and PMMA groups, which were statistically similar (P>.05). Precision differed significantly among the 3 studied groups (P<.001). PEEK was the most precisely scanned material followed by titanium, and the PMMA group had the least precision. Regarding scannability, there were overall significant differences (P<.001). Titanium was the most scannable, followed by PEEK and then PMMA. CONCLUSIONS Airborne-particle abraded titanium had better trueness and scannability than PEEK and PMMA. However, PEEK was the most precisely scanned material.
Collapse
Affiliation(s)
- Nourhan Samy Emam
- Assistant Lecturer, Department of Prosthodontics, Faculty of Dentistry, El-Zagazig University, Zagazig, Sharqia Governorate, Egypt; and PhD Researcher, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Bab Sharqi, Alexandria Governorate, Egypt.
| | - Mohamed Moataz Khamis
- Professor and Chairman, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Bab Sharqi, Alexandria Governorate, Egypt
| | - Ahmed Mohamed Abdelhamid
- Professor, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Bab Sharqi, Alexandria Governorate, Egypt
| | - Salah Ezzelarab
- Professor, Department of Prosthodontics, Faculty of Dentistry, Alexandria University, Bab Sharqi, Alexandria Governorate, Egypt
| |
Collapse
|
31
|
Luo T, Xie C, Wu J, Zhu J, Yu H. A digital strategy for intraoperative acquisition of actual drill position and rapid assessment of bony preparation accuracy using an intraoral scanner. Heliyon 2023; 9:e18004. [PMID: 37483804 PMCID: PMC10362229 DOI: 10.1016/j.heliyon.2023.e18004] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/03/2022] [Revised: 07/02/2023] [Accepted: 07/05/2023] [Indexed: 07/25/2023] Open
Abstract
A digital workflow to acquire actual position of the drill and assess bony preparation accuracy intraoperatively was described. Based on the widely used intraoral scanner, this digital workflow was a relatively practical and economical option for digital intraoperative measurement. As a result, it could help the clinician in accurate verification and immediate correction of the drill position and consequently facilitating the accurate implant placement in implant surgery.
Collapse
Affiliation(s)
- Tian Luo
- State Key Laboratory of Oral Disease, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Chenyang Xie
- Department of Dental Technology, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Jiacheng Wu
- Department of Dental Technology, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Jiakang Zhu
- State Key Laboratory of Oral Disease, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| | - Haiyang Yu
- State Key Laboratory of Oral Disease, National Clinical Research Center for Oral Diseases, West China Hospital of Stomatology, Sichuan University, Chengdu, China
| |
Collapse
|
32
|
Torres A, Dierickx M, Coucke W, Pedano MS, Lambrechts P, Jacobs R. Ex-vivo and in-vivo validation of a novel measuring protocol for guided endodontics. J Dent 2023:104566. [PMID: 37263407 DOI: 10.1016/j.jdent.2023.104566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2022] [Revised: 05/23/2023] [Accepted: 05/27/2023] [Indexed: 06/03/2023] Open
Abstract
OBJECTIVES To (1) validate the use of a post-operative intraoral scan (IOS) versus Cone Beam Computed Tomography (CBCT), gold standard, on its ability to measure the accuracy of guided endodontics, and (2) present clinical data on the accuracy of guided endodontics. METHODS Four models, including 10 extracted teeth each, were created. Forty guided access cavities were planned on dentin to simulate pulp canal obliteration (PCO). Two operators performed guided access cavities. A post-operative CBCT and IOS were acquired. The deviation coronally, apically, and angular deviation was measured with CBCT and IOS. Clinical accuracy was measured using an IOS acquired immediately after drilling the access cavity with the aid of a guide. Data analysis was performed using multiway Anova and corrected for simultaneous hypothesis testing according to Tukey. P ≤ 0.05 was considered statistically significant. Descriptive statistics on the clinical accuracy of guided endodontics were performed. RESULTS Thirty-eight cavities were assessed with a mean length of 13.8 mm. No statistical difference between operators and methods was found for all parameters (P > 0.05). Thirty-three patients were treated with guided endodontics and measured using an IOS. Results show an average coronal, apical, and angular deviation of 0.2 mm, 0.45 mm, and 1.91° respectively. The average length of the access cavities was 12.5 mm. CONCLUSIONS An IOS can be used to measure the accuracy of guided endodontics. Clinical data showed high accuracy of guided endodontics with a mean apical deviation smaller than 0.5 mm and a mean angular deviation of less than 2°. CLINICAL SIGNIFICANCE The use of an IOS does not involve additional radiation exposure. A safety margin of at least 1 mm around the planned trajectory should be respected when planning the case to minimize the possibility of root perforation.
Collapse
Affiliation(s)
- A Torres
- OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, and Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium; Department of Oral Health Sciences, Endodontology, University Hospitals Leuven, KU Leuven, Leuven, Belgium.
| | - M Dierickx
- Department of Oral Health Sciences, Endodontology, University Hospitals Leuven, KU Leuven, Leuven, Belgium.
| | - W Coucke
- Certified Freelance Statistician, Heverlee, Belgium.
| | - M S Pedano
- Department of Oral Health Sciences, Endodontology, University Hospitals Leuven, KU Leuven, Leuven, Belgium.
| | - P Lambrechts
- Department of Oral Health Sciences, Endodontology, University Hospitals Leuven, KU Leuven, Leuven, Belgium.
| | - R Jacobs
- OMFS-IMPATH Research Group, Department of Imaging and Pathology, Faculty of Medicine, University of Leuven, and Department of Oral and Maxillofacial Surgery, University Hospitals Leuven, Leuven, Belgium; Department of Dental Medicine, Karolinska Institutet, Stockholm, Sweden.
| |
Collapse
|
33
|
Drancourt N, Auduc C, Mouget A, Mouminoux J, Auroy P, Veyrune JL, El Osta N, Nicolas E. Accuracy of Conventional and Digital Impressions for Full-Arch Implant-Supported Prostheses: An In Vitro Study. J Pers Med 2023; 13:jpm13050832. [PMID: 37241002 DOI: 10.3390/jpm13050832] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/27/2023] [Revised: 05/11/2023] [Accepted: 05/12/2023] [Indexed: 05/28/2023] Open
Abstract
Both conventional and digital impressions aim to record the spatial position of implants in the dental arches. However, there is still a lack of data to justify the use of intraoral scanning over conventional impressions for full-arch implant-supported prostheses. The objective of the in vitro study was to compare the trueness and precision of conventional and digital impressions obtained with four intra-oral scanners: Trios 4 from 3Shape®, Primescan from Dentsply Sirona®, CS3600 from Carestream® and i500 from Medit®. This study focused on the impression of an edentulous maxilla in which five implants were placed for implant-supported complete prosthesis. The digital models were superimposed on a digital reference model using dimensional control and metrology software. Angular and distance deviations from the digital reference model were calculated to assess trueness. Dispersion of the values around their mean for each impression was also calculated for precision. The mean distance deviation in absolute value and the direction of the distance deviation were smaller for conventional impressions (p-value < 0.001). The I-500 had the best results regarding angular measurements, followed by Trios 4 and CS3600 (p < 0.001). The conventional and I-500 digital impressions showed the lowest dispersion of values around the mean (p-value < 0.001). Within the limitations of our study, our results revealed that the conventional impression was more accurate than the digital impression, but further clinical studies are needed to confirm these findings.
Collapse
Affiliation(s)
- Noemie Drancourt
- UFR d'Odontologie, Centre de Recherche en Odontologie Clinique (CROC), Université Clermont Auvergne, CROC, F-63000 Clermont-Ferrand, France
- CHU Clermont-Ferrand, Service d'Odontologie, F-63003 Clermont-Ferrand, France
| | - Chantal Auduc
- CHU Clermont-Ferrand, Service d'Odontologie, F-63003 Clermont-Ferrand, France
| | - Aymeric Mouget
- CHU Clermont-Ferrand, Service d'Odontologie, F-63003 Clermont-Ferrand, France
| | - Jean Mouminoux
- CHU Clermont-Ferrand, Service d'Odontologie, F-63003 Clermont-Ferrand, France
| | - Pascal Auroy
- UFR d'Odontologie, Centre de Recherche en Odontologie Clinique (CROC), Université Clermont Auvergne, CROC, F-63000 Clermont-Ferrand, France
- CHU Clermont-Ferrand, Service d'Odontologie, F-63003 Clermont-Ferrand, France
| | - Jean-Luc Veyrune
- UFR d'Odontologie, Centre de Recherche en Odontologie Clinique (CROC), Université Clermont Auvergne, CROC, F-63000 Clermont-Ferrand, France
- CHU Clermont-Ferrand, Service d'Odontologie, F-63003 Clermont-Ferrand, France
| | - Nada El Osta
- UFR d'Odontologie, Centre de Recherche en Odontologie Clinique (CROC), Université Clermont Auvergne, CROC, F-63000 Clermont-Ferrand, France
| | - Emmanuel Nicolas
- UFR d'Odontologie, Centre de Recherche en Odontologie Clinique (CROC), Université Clermont Auvergne, CROC, F-63000 Clermont-Ferrand, France
- CHU Clermont-Ferrand, Service d'Odontologie, F-63003 Clermont-Ferrand, France
| |
Collapse
|
34
|
Agustín-Panadero R, Moreno DM, Pérez-Barquero JA, Fernández-Estevan L, Gómez-Polo M, Revilla-León M. Influence of type of restorative materials and surface wetness conditions on intraoral scanning accuracy. J Dent 2023; 134:104521. [PMID: 37061118 DOI: 10.1016/j.jdent.2023.104521] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2022] [Revised: 03/26/2023] [Accepted: 04/12/2023] [Indexed: 04/17/2023] Open
Abstract
OBJECTIVES To assess the influence of different restorative materials and surface wetness on intraoral scanning accuracy. METHODS Reference casts with an extracted second premolar and first and second molar were digitized (L2). Four groups were established according to the material of the first molar: natural tooth (control), zirconia (Z), lithium disilicate (LD), and nanoceramic resin crown (NC). Four subgroups were developed: dry, low-, mild-, and high-wetness subgroups (n=15). All the scans were completed by using an intraoral scanner (TRIOS 3). In the control-dry subgroup, the reference cast was dry. In the control-low subgroup, artificial saliva was sprayed with a 1 mL/min volumetric flow for 4 seconds. In the control-mild and control-high subgroups, the same procedures as in the control-low subgroup were performed, but with a volumetric flow of 4 and of 8 mL/min, respectively. In the Z, LD and NC groups, each crown was fabricated with its respective material. Trueness was analyzed using 2-way ANOVA and Bonferroni tests. The Levene and Bonferroni tests were used to assess precision (α=.05). RESULTS Material (P<.001) and wetness (P<.001) significantly influenced trueness and precision. The mild and high subgroups revealed lower trueness and precision compared with the dry and low subgroups. The control, Z, and LD groups under dry and low wetness conditions showed better trueness compared with the NC group, but the materials tested had no significant precision discrepancies. Under mild wetness conditions, all the materials showed no significant trueness discrepancies. Under high wetness conditions, the LD group demonstrated the best trueness and precision. CONCLUSIONS The restorative materials and surface wetness tested influenced scanning trueness and precision of the IOS assessed. CLINICAL SIGNIFICANCE Dried surfaces are recommended to maximize the scanning accuracy values of the IOS tested. Overall, the presence of saliva can reduce the performance of the IOS tested.
Collapse
Affiliation(s)
- Rubén Agustín-Panadero
- Associate Professor Department of Stomatology, School of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | | | - Jorge Alonso Pérez-Barquero
- Adjunt Professor, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | - Lucía Fernández-Estevan
- Associate Lecturer, Department of Dental Medicine, Faculty of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | - Miguel Gómez-Polo
- Associate Professor Department of Conservative Dentistry and Prosthodontics, Director of postgraduate program of Advanced in Implant-Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain.
| | - Marta Revilla-León
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA; Director of Research and Digital Dentistry, Kois Center, Seattle, WA; and Adjunct Professor, Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, MA
| |
Collapse
|
35
|
Zingari F, Meglioli M, Gallo F, Macaluso GM, Tagliaferri S, Toffoli A, Ghezzi B, Lumetti S. Predictability of intraoral scanner error for full-arch implant-supported rehabilitation. Clin Oral Investig 2023:10.1007/s00784-023-05011-4. [PMID: 37041271 DOI: 10.1007/s00784-023-05011-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2022] [Accepted: 03/28/2023] [Indexed: 04/13/2023]
Abstract
OBJECTIVES The present study aimed to analyze the behaviors of three intraoral scanners (IOSs): evaluating the interdistance and axial inclination discrepancies in full-arch scans, predictable errors were searched. MATERIALS AND METHODS Six edentulous sample models with variable numbers of dental implants were used; reference data were obtained with a coordinate-measuring machine (CMM). Each IOS (i.e., Primescan, CS3600, and Trios3) performed 10 scans per model (180 total scans). The origin of each scan body was used as a reference point to measure interdistance lengths and axial inclinations. Precision and trueness of interdistance measurements and axial inclinations were evaluated to address error predictability. Bland-Altman analysis, followed by linear regression analysis and Friedman's test (plus Dunn's post hoc correction), was performed to evaluate the precision and trueness. RESULTS Regarding interdistance, Primescan showed the best precision (mean ± SD: 0.047 ± 0.020 mm), while Trios3 underestimated the reference value more than the others (p < 0.001) and had the worst performance (mean ± SD: -0.079 ± 0.048 mm). Concerning the inclination angle, Primescan and Trios3 tended to overestimate angle values, while CS3600 underestimated them. Primescan had fewer inclination angle outliers, but it tended to add 0.4-0.6° to the measurements. CONCLUSIONS IOSs showed predictable errors: they tended to overestimate or underestimate linear measurements and axial inclinations of scan bodies, one added 0.4-0.6° to the angle inclination values. In particular, they showed heteroscedasticity, a behavior probably related to the software or the device itself. CLINICAL SIGNIFICANCE IOSs showed predictable errors that could affect clinical success. When performing a scan or choosing a scanner, clinicians should clearly know their behaviors.
Collapse
Affiliation(s)
- Francesco Zingari
- Center of Dental Medicine, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy
- Department of Maxillofacial Surgery, Galeazzi Hospital, Milan, Italy
- Department of Biomedical, Surgical and Dental Sciences, School of Dentistry, University of Milan, Milan, Italy
| | - Matteo Meglioli
- Center of Dental Medicine, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy
| | - Francesco Gallo
- Department of Biomedical, Surgical and Dental Sciences, School of Dentistry, University of Milan, Milan, Italy
- Department of Maxillofacial Surgery, Italian Stomatologic Institute, Milan, Italy
| | - Guido Maria Macaluso
- Center of Dental Medicine, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy.
- IMEM-CNR, Parco Area delle Scienze 37/A, 43124, Parma, Italy.
| | - Sara Tagliaferri
- Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy
- CERT, Center of Excellence for Toxicological Research, University of Parma, Parma, Italy
| | - Andrea Toffoli
- Center of Dental Medicine, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy
| | - Benedetta Ghezzi
- Center of Dental Medicine, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy
| | - Simone Lumetti
- Center of Dental Medicine, Department of Medicine and Surgery, University of Parma, Via Gramsci 14, 43126, Parma, Italy
| |
Collapse
|
36
|
Sicilia E, Lagreca G, Papaspyridakos P, Finkelman M, Cobo J, Att W, Revilla-León M. Effect of supramucosal height of a scan body and implant angulation on the accuracy of intraoral scanning: An in vitro study. J Prosthet Dent 2023:S0022-3913(23)00060-4. [PMID: 36828728 DOI: 10.1016/j.prosdent.2023.01.018] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2022] [Revised: 01/15/2023] [Accepted: 01/18/2023] [Indexed: 02/25/2023]
Abstract
STATEMENT OF PROBLEM Intraoral scanners (IOSs) provide a digital alternative to conventional implant impression techniques. However, the effect of the supramucosal height of the scan body and implant angulation on the accuracy of IOSs remains unclear. PURPOSE The purpose of this in vitro study was to measure the impact of the supramucosal height of the scan body and implant angulation on the accuracy (trueness and precision) of intraoral digital implant scans in partially edentulous models. MATERIAL AND METHODS Two maxillary partially edentulous casts with 4 implant analogs were fabricated, 1 with 4 parallel implants (P-groups) and 1 with 2 implants distally inclined 18 degrees (A-groups). An implant scan body was positioned on each implant analog (CARES RC Mono Scanbody). For each cast, 3 subgroups were determined based on the soft tissue moulage fabricated for each reference cast exposing 3 mm (P-3 and A-3 subgroups), 5 mm (P-5 and A-5 subgroups), and 7 mm (P-7 and A-7 subgroups) of the implant scan bodies. The 2 reference casts were registered by using a coordinate measurement machine and desktop scanner (7 Series Dental Wings) and then scanned using an IOS (TRIOS 4) (n=15). Linear and angular discrepancy values and root mean square (RMS) error values between the implant scan bodies measured on the reference and experimental scans were computed with an inspection software program (Geomagic). Mann-Whitney U tests with Bonferroni correction were applied for planned comparisons (α=.05/9 ≈ .006). RESULTS For linear discrepancies, statistically significant differences were found between groups P-3 and A-3 (P=.004) and between P-7 and A-7 (P=.005). For angular discrepancies, statistically significant differences were found between groups A-3 and A-5 (P=.002) and between P-7 and A-7 (P=.003). The RMS error analysis found no statistically significant differences among the groups. CONCLUSIONS Implant angulation of 18 degrees did not significantly affect the accuracy of the intraoral scans in terms of 6 of the 9 planned comparisons, although the angled groups had lower mean values. Also, the supramucosal height of the scan body did not significantly affect the accuracy of the intraoral scans in terms of 17 of the 18 planned comparisons. Results may vary with different implant scan body designs.
Collapse
Affiliation(s)
- Elena Sicilia
- PhD Candidate, Department of Prosthodontics and Occlusion, School of Dentistry, University of Oviedo, Oviedo, Spain.
| | - Gabriela Lagreca
- Assistant Professor, Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Mass
| | - Panos Papaspyridakos
- Associate Professor, Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Mass
| | - Matthew Finkelman
- Associate Professor, Department of Public Health and Community Service, Tufts University School of Dental Medicine, Boston, Mass
| | - Juan Cobo
- Director of Orthodontics, Department of Surgery and Medical-Surgical Specialties, Area of Orthodontics, Medical and Dental School, Instituto Asturiano de Odontologia, University of Oviedo, Oviedo, Spain
| | - Wael Att
- Department Chair, Department of Prosthodontics, Tufts University School of Dental Medicine, Boston, Mass
| | | |
Collapse
|
37
|
Tohme H, Lawand G, Chmielewska M, Makhzoume J. Comparison between stereophotogrammetric, digital, and conventional impression techniques in implant-supported fixed complete arch prostheses: An in vitro study. J Prosthet Dent 2023; 129:354-362. [PMID: 34112521 DOI: 10.1016/j.prosdent.2021.05.006] [Citation(s) in RCA: 25] [Impact Index Per Article: 25.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 05/07/2021] [Accepted: 05/07/2021] [Indexed: 11/26/2022]
Abstract
STATEMENT OF PROBLEM Conventional impressions and digital intraoral scanning for implant-supported fixed complete arch prostheses still have many problems that influence accuracy. Although stereophotogrammetry may offer a reliable alternative to other techniques, it has seldom been investigated. PURPOSE The purpose of this in vitro study was to measure and compare the intraoral scan body deviations of the reference cast with the intraoral scan body distortions obtained by conventional, digital, and stereophotogrammetric techniques. MATERIALS AND METHODS An edentulous maxillary "all-on-four" cast was prepared with 2 straight and two 17-degree angled screw-retained abutments screwed on the implant. Three capture techniques were compared: the conventional impression technique (CI group) using impression plaster (IP), the digital intraoral scanning (DIS group) technique, and the stereophotogrammetry (SPG group) technique. A calibrated extraoral scanner was used to digitize the definitive cast to compare its intraoral scan body positions with those of the other techniques in terms of global angular distortion and 3D deviations of the whole scan body and flat angled surface alone by using an inspection and metrology software program and the best fit alignment technique. The Kolmogorov-Smirnov and Shapiro-Wilk tests showed normal distribution of the quantitative variables. Thus, the repeated measures analyses of variance followed by univariate analysis and Bonferroni multiple comparison tests were performed to analyze the data (α=.05). RESULTS Significant global angular discrepancies and 3D deviations of the whole scan body and flat angled surface were found among the CI, DI, and SPG groups for both trueness (P<.001) and precision (P<.001). CONCLUSIONS The stereophotogrammetry capture technique reported the highest accuracy in terms of trueness and precision for the intraoral scan bodies of all the techniques evaluated. However, at the flat angled surface region of the scan body, higher trueness was detected with the digital technique. Conventional impressions showed better trueness results than the digital ones, but the opposite was true of precision.
Collapse
Affiliation(s)
- Hani Tohme
- Clinical Director of Postgraduate Program, Department of Removable Prosthodontics, Faculty of Dental Medicine, Saint Joseph University, Beirut, Lebanon.
| | - Ghida Lawand
- Post graduate student, Department of Prosthodontics and Esthetic Dentistry, Faculty of Dental Medicine, Saint Joseph University, Beirut, Lebanon
| | | | - Joseph Makhzoume
- Professor and Dean, Department of Removable Prosthodontics, Faculty of Dental Medicine, Saint Joseph University, Beirut, Lebanon
| |
Collapse
|
38
|
Gracis S, Appiani A, Noè G. Digital workflow in implant prosthodontics: The critical aspects for reliable accuracy. J ESTHET RESTOR DENT 2023; 35:250-261. [PMID: 36606714 DOI: 10.1111/jerd.13004] [Citation(s) in RCA: 7] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/24/2022] [Revised: 12/13/2022] [Accepted: 12/14/2022] [Indexed: 01/07/2023]
Abstract
INTRODUCTION This paper is a comprehensive treaty about the variables that influence the transfer of the position of an implant to the laboratory when using a digital workflow. OBJECTIVE The aim is to provide operators and manufacturers with a guide on how to improve certain aspects of the digital workflow specific to the fabrication of implant-supported restorations. OVERVIEW It addresses intraoral scanning issues and CAD software issues. In the former, the variables that play a part in the quality of the scan file are investigated: the implant scan body, the IOS and the operator. For the latter, instead, the focus is on those aspects that still today may create inaccuracies in the workflow and in the final product being fabricated: the identification of the specific implant placed in the patient and the generation of a virtual model with the representation of that implant platform correctly positioned in the three dimensions of space. Suggestions and recommendations are given to improve the control on the quality of the digital workflow's output. CONCLUSION In a digital workflow for the fabrication of an implant-supported restoration, the selection and use of the implant scan body, the use of an effective scan strategy and the appropriateness of the best fit function in the CAD software, that is, the procedure of superimposing the library of geometric shapes of the ISB linked to the implant with the shape acquired intraorally, are variables that can influence the positional precision of the FDP. CLINICAL SIGNIFICANCE Fully understanding the importance of the information enclosed in the ISBs themselves can be crucial in the digital workflow. A proper ISB's selection, a correct scan of the ISB's shape and an accurate CAD superimposition of the ISB's library can lead the clinician to reduce the variables that affect the final result in daily practice.
Collapse
|
39
|
Revilla-León M, Kois DE, Kois JC. A guide for maximizing the accuracy of intraoral digital scans: Part 2-Patient factors. J ESTHET RESTOR DENT 2023; 35:241-249. [PMID: 36639916 DOI: 10.1111/jerd.12993] [Citation(s) in RCA: 31] [Impact Index Per Article: 31.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/12/2022] [Revised: 10/31/2022] [Accepted: 11/14/2022] [Indexed: 01/15/2023]
Abstract
OBJECTIVES To describe the factors related to patient intraoral conditions that impact the scanning accuracy of intraoral scanners (IOSs). A new classification for these influencing factors is proposed to facilitate dental professionals' decision-making and maximize the accuracy and reliability of intraoral digital scans. OVERVIEW Variables related to intraoral conditions of the patient that can influence the scanning accuracy of IOSs include tooth type, presence of interdental spaces, arch width variations, palate characteristics, wetness, existing restorations, characteristics of the surface being digitized, edentulous areas, interimplant distance, position, angulation, and depth of existing implants, and implant scan body selection. CONCLUSIONS The knowledge and understanding of the patient's intraoral conditions that can impact the scanning accuracy of IOSs is a fundamental element for maximizing the accuracy of IOSs. CLINICAL SIGNIFICANCE The patient's intraoral conditions, or patient factors, can significantly impact intraoral scanning accuracy. Dental professionals must know and understand these influencing patient factors to maximize the accuracy of IOSs.
Collapse
Affiliation(s)
- Marta Revilla-León
- Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Washington, USA.,Research and Digital Dentistry, Kois Center, Seattle, Washington, USA.,Department of Prosthodontics, Tufts University, Boston, Massachusetts, USA
| | - Dean E Kois
- Kois Center, Seattle, Washington, USA.,Private Practice, Seattle, Washington, USA
| | - John C Kois
- Kois Center, Seattle, Washington, USA.,Private Practice, Seattle, Washington, USA.,Department of Restorative Dentistry, University of Washington, Seattle, Washington, USA
| |
Collapse
|
40
|
Kaya G, Bilmenoglu C. Accuracy of 14 intraoral scanners for the All-on-4 treatment concept: a comparative in vitro study. J Adv Prosthodont 2022; 14:388-398. [PMID: 36685788 PMCID: PMC9832143 DOI: 10.4047/jap.2022.14.6.388] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 11/23/2022] [Accepted: 12/01/2022] [Indexed: 12/28/2022] Open
Abstract
PURPOSE This in vitro study aimed to evaluate the accuracy of 14 different intraoral scanners for the All-on-4 treatment concept. MATERIALS AND METHODS Four implants were placed in regions 13, 16, 23, and 26 of an edentulous maxillary model that was poured with scannable Type 4 gypsum to imitate the All-on-4 concept. The cast was scanned 10 times for each of 14 intraoral scanners (Primescan, iTero 2, iTero 5D, Virtuo Vivo, Trios 3, Trios 4, CS3600, CS3700, Emerald, Emerald S, Medit i500, BenQ BIS-I, Heron IOS, and Aadva IOS 100P) after the polyether ether ketone scanbody was placed. For the control group, the gypsum model was scanned 10 times with an industrial scanner. The first of the 10 virtual models obtained from the industrial model was chosen as the reference model. For trueness, the data of the 14 dental scanners were superimposed with the reference model; for precision, the data of all 14 scanners were superimposed within the groups. Statistical analyses were performed using the Kolmogorov-Smirnov, Shapiro-Wilks, and Dunn's tests. RESULTS Primescan showed the highest trueness and precision values (P < .005), followed by the iTero 5D scanner (P < .005). CONCLUSION Some of these digital scanners can be used to make impressions within the All-on-4 concept. However, the possibility of data loss due to artifacts, reflections, and the inability to combine the data should be considered.
Collapse
Affiliation(s)
- Gözde Kaya
- Department of Prosthodontics, Faculty of Dentistry, Trakya University, Edirne, Turkey
| | - Caglar Bilmenoglu
- Department of Prosthodontics, Faculty of Dentistry, Trakya University, Edirne, Turkey
| |
Collapse
|
41
|
Gómez-Polo M, Ortega R, Sallorenzo A, Agustín-Panadero R, Barmak AB, Kois JC, Revilla-León M. Influence of the surface humidity, implant angulation, and interimplant distance on the accuracy and scanning time of complete-arch implant scans. J Dent 2022; 127:104307. [PMID: 36162637 DOI: 10.1016/j.jdent.2022.104307] [Citation(s) in RCA: 14] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/25/2022] [Revised: 08/22/2022] [Accepted: 09/22/2022] [Indexed: 12/14/2022] Open
Abstract
OBJECTIVES To assess the influence of implant angulation, humidity, and interimplant distance on the accuracy and scanning time of complete-arch implant scans. METHODS A definitive cast with 4 parallel implant abutment analogs (P group), and another cast with 4 angulated (up to 30 degrees) implant abutment analogs (NP group) were digitized by using a scanner (7Series) (reference scans). Two subgroups were created: dry (D subgroup) and wet (W subgroup). For the D subgroup, the casts were digitized without altering the surface humidity by using an intraoral scanner (IOS) (TRIOS 3). For the W subgroup, the cast surface was humidified with artificial saliva and digitized by using the same IOS. The interimplant distance discrepancies were assessed by computing linear and angular measurements. Trueness data was analyzed using 3-way ANOVA followed by the pairwise comparison Tukey tests. The Bartlett test, followed by the pairwise comparison tests, was used to assess the precision (α=.05). RESULTS Regarding the trueness, implant angulation (P<.001) and inter-implant distance measurement (P<.001) influenced the linear discrepancies. Implant angulation (P=.002), humidity conditions (P<.001), and inter-implant distance (P=.001) influenced the angular discrepancies. Regarding the precision, significant differences in the variance of linear and angular measurements and inter-implant distances were found. Humidity conditions (P<.001) influenced the scanning time. CONCLUSIONS Implant angulation, humidity, and interimplant distance influenced the accuracy and scanning time of complete-arch implant scans. Parallel implants resulted in higher trueness and precision values. Dry conditions resulted in slightly higher scanning trueness and precision and shorter scanning time. CLINICAL SIGNIFICANCE Drying the surface being scanned increases intraoral scanning accuracy and decreases intraoral scanning time.
Collapse
Affiliation(s)
- Miguel Gómez-Polo
- Associate Professor Department of Conservative Dentistry and Prosthodontics, Director of postgraduate program of Advanced in Implant-Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain
| | - Rocío Ortega
- Adjunct Professor Department of Prosthetic Dentistry, School of Dentistry, European University of Madrid, Madrid, Spain
| | - Alessandro Sallorenzo
- Postgraduate Specialist in Advanced-Prosthodontics. Department of Conservative Dentistry and Prosthodontics, School of Dentistry, Complutense University of Madrid, Madrid, Spain
| | - Rubén Agustín-Panadero
- Associate Professor Department of Stomatology, School of Medicine and Dentistry, University of Valencia, Valencia, Spain
| | - Abdul B Barmak
- Assistant Professor Clinical Research and Biostatistics, Eastman Institute of Oral Health, University of Rochester Medical Center, Rochester, NY, USA
| | - John C Kois
- Founder and Director Kois Center, Seattle, WA, USA; Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, University of Washington, Seattle, WA, USA; Private Practice, Seattle, WA, USA
| | - Marta Revilla-León
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, WA, USA; Faculty and Director of Research and Digital Dentistry, Kois Center, Seattle, WA, USA; Adjunct Professor, Department of Prosthodontics, School of Dental Medicine, Tufts University, Boston, MA, USA.
| |
Collapse
|
42
|
Dohiem MM, Abdelaziz MS, Abdalla MF, Fawzy AM. Digital assessment of the accuracy of implant impression techniques in free end saddle partially edentulous patients. A controlled clinical trial. BMC Oral Health 2022; 22:486. [PMID: 36371189 DOI: 10.1186/s12903-022-02505-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/03/2022] [Accepted: 10/11/2022] [Indexed: 11/15/2022] Open
Abstract
Abstract
Objectives
This in vivo study aims to assess the accuracy of the digital intraoral implant impression technique, the conventional closed-tray impression technique, and open-tray impression techniques in a standardized method of data segmentation along with the best-fit algorithm to overcome the inconsistency of results of previous studies regarding implant impression techniques.
Materials and methods
Sixteen implants were placed in eight patients. Each patient has undergone four impression techniques: direct intraoral scanning of the stock abutment, intraoral scanning using a scan body, conventional closed tray impression technique, and the conventional open tray impression technique. The conventional impressions were poured into stone casts with analogues and stock abutments and scanned using a desktop scanner. In intraoral scanning of the scan body, computer-aided design software was used for the replacement of the scan body with a custom-made abutment that is identical to the stock abutment, allowing comparison with the other impression techniques. The deviation in implant position between the groups was measured using special 3D inspection and metrology software. Statistical comparisons were carried out between the studied groups using a one-way analysis of variance (ANOVA) test.
Results
The total deviation between groups was compared to the reference group represented by the intraoral scanning of the abutment. The total deviation was statistically significantly different (P = 0.000) among the different studied groups. The mean deviation was recorded as 21.45 ± 3.3 μm, 40.04 ± 4.1 μm, and 47.79 ± 4.6 μm for the intraoral scanning of the scan body, the conventional closed, and open tray, respectively.
Conclusion
For implant impressions in partially edentulous patients, intraoral oral scanning using a scan body significantly improves scanning and overall accuracy. Regarding conventional impressions, the closed-tray impression techniques showed more accuracy than conventional open-tray impressions.
Clinical relevance
Intraoral digital implant impression using scan body offers more accuracy than conventional implant impression techniques for recording posterior implant position in free-end saddle partially edentulous patients.
Collapse
|
43
|
Kato T, Yasunami N, Furuhashi A, Sanda K, Ayukawa Y. Effects of Autoclave Sterilization and Multiple Use on Implant Scanbody Deformation In Vitro. MATERIALS (BASEL, SWITZERLAND) 2022; 15:7717. [PMID: 36363311 PMCID: PMC9655283 DOI: 10.3390/ma15217717] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/12/2022] [Revised: 10/26/2022] [Accepted: 10/27/2022] [Indexed: 06/16/2023]
Abstract
In the intraoral scanner (IOS) impression technique for dental implants, a scanbody (SB) is connected to the implant and scanned. Poly(ether-ether-ketone) (PEEK) is a widely used material for SBs and it is recommended for single use. However, from the perspective of the Sustainable Development Goals, it is desirable to use these products multiple times. As SBs are used in patients' mouths, proper sterilization is necessary for multiple uses. In the present study, the effect of autoclave treatment and connection/disconnection on SB deformation was investigated. The SB was connected to the implant and stereolithography (STL) data were obtained. Then, the SB was disconnected and underwent autoclave treatment, or was connected and disconnected multiple times, or underwent a combination of both processes. The results showed that there were significant differences in the distance and angle when comparing SBs before and after the autoclave treatment, but repeated connections with or without autoclave treatment had no significant impact on the measured values. The surface texture, observed with scanning electron microscopy, showed that a groove was observed on the surface of the SB, but the groove did not show major changes after 10 connection/autoclave processes. These results indicate that autoclave sterilization has some impact on SB deformation but connection/disconnection itself may not have a huge impact on SB deformation.
Collapse
|
44
|
Bi C, Wang X, Tian F, Qu Z, Zhao J. Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluations. J Adv Prosthodont 2022; 14:236-249. [PMID: 36105881 PMCID: PMC9444482 DOI: 10.4047/jap.2022.14.4.236] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/06/2022] [Revised: 06/15/2022] [Accepted: 07/29/2022] [Indexed: 11/12/2022] Open
Abstract
PURPOSE The present study compared the accuracy between digital and conventional implant impressions. MATERIALS AND METHODS The experimental models were divided into six groups depending on the implant location and the scanning span. Digital impressions were captured using the intraoral optical scanner TRIOS (3Shape, Copenhagen, Denmark). Conventional impressions were taken with the monophase impression material based on addition-cured silicones, Honigum-Mono (DMG, Hamburg, Germany). A high-precision laboratory scanner D900 (3Shape, Copenhagen, Denmark) was used to obtain digital data of resin models and stone casts. Surface tessellation language (STL) datasets from scanner were imported into the analysis software Geomagic Qualify 14 (3D Systems, Rock Hill, SC, USA), and scan body deviations were determined through two-dimensional and three-dimensional analyses. Each scan body was measured five times. The Sidak t test was used to analyze the experimental data. RESULTS Implant position and scanning distance affected the impression accuracy. For a unilateral arch implant and the mandible models with two implants, no significant difference was observed in the accuracy between the digital and conventional implant impressions on scan bodies; however, the corresponding differences for trans-arch implants and mandible with six implants were extremely significant (P<.001). CONCLUSION For short-span scanning, the accuracy of digital and conventional implant impressions did not differ significantly. For long-span scanning, the precision of digital impressions was significantly inferior to that of the traditional impressions.
Collapse
Affiliation(s)
- Chuang Bi
- Dalian Stomatological Hospital, Dalian, Liaoning Province, China
| | - Xingyu Wang
- Dalian Medical University, Dalian, Liaoning Province, China
| | - Fangfang Tian
- Dalian Medical University, Dalian, Liaoning Province, China
| | - Zhe Qu
- Dalian Stomatological Hospital, Dalian, Liaoning Province, China
| | - Jiaming Zhao
- Dalian Stomatological Hospital, Dalian, Liaoning Province, China
| |
Collapse
|
45
|
Lawand G, Ismail Y, Revilla-León M, Tohme H. Effect of implant scan body geometric modifications on the trueness and scanning time of complete arch intraoral implant digital scans: An in vitro study. J Prosthet Dent 2022:S0022-3913(22)00378-X. [PMID: 35864021 DOI: 10.1016/j.prosdent.2022.06.004] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/18/2022] [Revised: 06/07/2022] [Accepted: 06/08/2022] [Indexed: 11/22/2022]
Abstract
STATEMENT OF PROBLEM The effect of the surface geometry of implant scan bodies (ISBs) on the accuracy and scanning time of complete-arch implant digital scans remains uncertain. PURPOSE The purpose of this in vitro study was to evaluate whether geometric modifications on implant scan bodies (nonmodified, subtractively modified, and additively modified ISBs) affect the trueness and scanning time of complete-arch intraoral implant digital scans. MATERIAL AND METHODS A completely edentulous maxillary cast with 2 anterior parallel and two 17-degree posteriorly tilted implant abutment analogs was prepared. A digitized reference was created from this cast with polyetheretherketone (PEEK) (CARES Mono Scanbody for screw-retained abutment) ISBs by using a desktop scanner (E3). Three different groups were created: nonmodified (NM group), subtractively modified (SM group), and additively modified (AM group). For the NM group, no modifications were made to the ISBs. For the SM group, 4 round-shaped grooves were created on the buccal, lingual, mesial, and distal sides. For the AM group, PEEK beads were printed and cemented on the same areas of the ISB of the SM group. Fifteen consecutive scans were captured with an intraoral scanner (TRIOS 3) for each group, and the scanning time was recorded. By using a metrology software program, scans of each group were superimposed on the reference file to determine the 3D surface, linear, and angular position discrepancies of each ISB. Repeated-measures analyses of variance followed by univariate analysis and Bonferroni multiple comparison tests were performed to analyze the data (α=.05). To compare the mean time among groups, 1-way analysis of variance was performed followed by the Tukey post hoc tests. RESULTS Significant 3D surface, linear, and angular position discrepancies were found when measuring trueness among the NM, SM, and AM groups (P<.001). Discrepancies in 3D surface deviation were highest for the AM group (0.266 ±0.030 mm), and the lowest mean angular deviation values were for the SM group (0.993 ±0.062 degrees). However, the mean scanning time was not significantly different among the groups tested (P=.237). CONCLUSIONS For complete-arch intraoral implant digital scans, subtractive modifications on ISBs enhanced scanning trueness, while additive modifications on ISBs decreased scanning trueness. However, implant scan body geometric modifications did not affect scanning time.
Collapse
Affiliation(s)
- Ghida Lawand
- Resident, Department of Prosthodontics and Esthetic Dentistry, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon.
| | - Yara Ismail
- Resident, Department of Prosthodontics and Esthetic Dentistry, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| | - Marta Revilla-León
- Affiliate Assistant Professor, Graduate Prosthodontics, Department of Restorative Dentistry, School of Dentistry, University of Washington, Seattle, Wash; Director of Research and Digital Dentistry, Kois Center, Seattle, Wash; Adjunct Professor, Department of Prosthodontics, Tufts University, Boston, Mass
| | - Hani Tohme
- Founder and Head of Digital Dentistry Unit, Postgraduate Program Director, Department of Removable Prosthodontics, Faculty of Dental Medicine, Saint Joseph University of Beirut, Beirut, Lebanon
| |
Collapse
|
46
|
Marques VR, Çakmak G, Yilmaz H, Abou-Ayash S, Donmez MB, Yilmaz B. Effect of Scanned Area and Operator on the Accuracy of Dentate Arch Scans with a Single Implant. J Clin Med 2022; 11:jcm11144125. [PMID: 35887889 PMCID: PMC9320255 DOI: 10.3390/jcm11144125] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2022] [Revised: 07/13/2022] [Accepted: 07/13/2022] [Indexed: 11/26/2022] Open
Abstract
Studies have shown the effect of the operator and scanned areas on the accuracy of single implant scans. However, the knowledge on the scan accuracy of the remaining dental arch during single implant scans, which may affect the occlusion, is limited. The aim of this study was to investigate the effect of scanned areas and the operator on the scan accuracy of a dentate arch while scanning a single implant. A dentate model with an anterior implant was digitized with a laboratory scanner (reference scan). Three operators with similar experience performed 10 complete- and 10 partial-arch scans (left 2nd molar to right canine) with an intraoral scanner (TRIOS 3), and these scans were superimposed over the reference. The accuracy was analyzed at 22 points in complete-arch and at 16 points in partial-arch scans on 2nd molars and incisors. Data were evaluated with 2-way ANOVA and Tukey HSD tests (α = 0.05). The trueness of the total scanned area was higher in partial- than in complete-arch scans (p < 0.001). The trueness and precision of the scans were higher in the anterior site compared with the posterior in complete- (trueness: p ≤ 0.022, precision: p ≤ 0.003) and partial-arch (trueness: p ≤ 0.016, precision: p ≤ 0.016) scans of each operator and when the operator scan data were pooled. The complete-arch scan’s precision was not influenced by the operator (p ≥ 0.029), whereas the partial-arch scans of operator 1 and 2 were significantly different (p = 0.036). Trueness was higher in partial- compared with complete-arch scans, but their precision was similar. Accuracy was higher in the anterior site regardless of the scan being a partial- or a complete-arch. The operator’s effect on the accuracy of partial- and complete-arch scans was small.
Collapse
Affiliation(s)
- Vinicius Rizzo Marques
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland; (V.R.M.); (G.Ç.); (S.A.-A.); (B.Y.)
| | - Gülce Çakmak
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland; (V.R.M.); (G.Ç.); (S.A.-A.); (B.Y.)
| | - Hakan Yilmaz
- İkon Oral and Dental Health Center, Istanbul 34275, Turkey;
| | - Samir Abou-Ayash
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland; (V.R.M.); (G.Ç.); (S.A.-A.); (B.Y.)
| | - Mustafa Borga Donmez
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland; (V.R.M.); (G.Ç.); (S.A.-A.); (B.Y.)
- Department of Prosthodontics, Faculty of Dentistry, Istinye University, Istanbul 34010, Turkey
- Correspondence:
| | - Burak Yilmaz
- Department of Reconstructive Dentistry and Gerodontology, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland; (V.R.M.); (G.Ç.); (S.A.-A.); (B.Y.)
- Department of Restorative, Preventive, and Pediatric Dentistry, School of Dental Medicine, University of Bern, 3012 Bern, Switzerland
- Division of Restorative and Prosthetic Dentistry, The Ohio State University, Columbus, OH 43210, USA
| |
Collapse
|
47
|
Misfit simulation on implant prostheses with different combinations of engaging and nonengaging titanium bases. Part 1: Stereomicroscopic assessment of the active and passive fit. J Prosthet Dent 2022; 129:589-596. [PMID: 35527068 DOI: 10.1016/j.prosdent.2022.04.009] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2021] [Revised: 04/13/2022] [Accepted: 04/14/2022] [Indexed: 11/23/2022]
Abstract
STATEMENT OF PROBLEM Little is known about whether the misfit level of implant-supported screw-retained prostheses can be tolerated when different combinations of engaging and nonengaging titanium bases are used. PURPOSE The purpose of this in vitro study was to simulate prosthetic workflow distortions (horizontal and vertical) and to evaluate the fit (passive and active) of 2-implant-supported screw-retained zirconia frameworks with 3 different combinations of abutments: both engaging, engaging and nonengaging, and both nonengaging. MATERIAL AND METHODS The fit of both engaging (n=10), engaging and nonengaging (n=10), and both nonengaging (n=10) 2-implant-supported zirconia frameworks was evaluated on control and definitive casts simulating 50-, 100-, and 150-μm vertical and 35-, 70-, 100-μm horizontal misfit levels. Stereomicroscopy was used to assess the passive fit (1 screw tightened) and active fit (both screws tightened) of the zirconia frameworks. Vertical deviations in the implant and abutment connection (the implant-abutment gap measured vertically) between the implant platform and reference line on the titanium base were measured. The Kruskal-Wallis and Mann-Whitney U tests (α=.05) were used to compare different implant-supported zirconia specimens on each definitive cast. RESULTS When 1 screw was tightened, both engaging specimens had higher vertical deviations (ranging from 40.1 to 131.1 μm) in 35- and 70-μm horizontal misfit levels, as compared with engaging and nonengaging (19.8 to 85.1 μm) and both nonengaging (6.6 to 14.3 μm) specimens. Comparing medians of the 100-μm misfit in horizontal (engaging and nonengaging 140.4 μm; both nonengaging 151.6 μm) and vertical (engaging and nonengaging 49.8 μm; both nonengaging 42.6 μm) directions, the horizontal misfits caused larger vertical deviations. When both screws were tightened in 50-, 100-, and 150-μm vertical misfit groups, the vertical gap increase in the engaging and nonengaging specimens was significantly higher than that in both the nonengaging specimens (P<.001). CONCLUSIONS As the level of simulated misfit increased, the vertical gap between the implant and abutment increased. Horizontal misfits were less tolerated than vertical ones and may be more detrimental. Both nonengaging 2-implant-supported zirconia frameworks were found to tolerate the different misfit levels better, followed by engaging and nonengaging and both engaging frameworks.
Collapse
|
48
|
Ebeid K, Nouh I, Ashraf Y, Cesar PF. Accuracy of different laboratory scanners for scanning of implant-supported full arch fixed prosthesis. J ESTHET RESTOR DENT 2022; 34:843-848. [PMID: 35441805 DOI: 10.1111/jerd.12918] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/02/2021] [Revised: 04/04/2022] [Accepted: 04/09/2022] [Indexed: 11/27/2022]
Abstract
OBJECTIVE This study evaluated the accuracy of different laboratory scanners (LS) for scanning of implant-supported full arch fixed prosthesis with different implant angulations. MATERIALS AND METHODS Two maxillary models that are designed to receive an all-on-four implant retained prosthesis were fabricated then scanned using five different LS. The models were divided into two groups according to the angulation of the posterior implant (Group 1; 30° and group 2; 45°). Each group was then subdivided into five subgroups according to the type of LS, subgroup T; Medit T710, subgroup I; IneosX5, subgroup E; 3ShapeE4, subgroup A; Autoscan DS-Mix, and subgroup M; Ceramill Map600. An industrial 3D scanner was used as reference scanner, then each model was scanned with 5 LS 10 times. Trueness and precision were analyzed using Geomagic 3D analysis software. RESULTS Both scanner type and implant angle had a significant effect on the trueness (p < 0.001). Significant interaction was found between the scanner type and implant angle (p < 0.001). For scanner type tukeys post hoc test revealed highest trueness with the 3Shape E4 (21.3 ± 2.1) and the medit T710 (22.6 ± 2.1) and least trueness with the shining 3D autoscan ds-mix (33.8 ± 3.0). Significantly better trueness was observed with the 30° than the 45° angle. Regarding precision, two-way ANOVA revealed significant effect of the scanner type only (p < 0.001). There were no significant differences between the 3Shape E4, medit T710, Ineos X5, and the Ceramill map600. However, all showed significantly higher precision values when compared to shining 3D autoscan ds-mix. CONCLUSIONS All tested scanners showed results within the clinically acceptable range with 3ShapeE4 and Medit T710 showing the highest accuracy. CLINICAL SIGNIFICANCE Tested scanners can be used for scanning of All-on-four implant supported prosthesis.
Collapse
Affiliation(s)
- Kamal Ebeid
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Ingy Nouh
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Yasmine Ashraf
- Department of Fixed Prosthodontics, Faculty of Dentistry, Ain Shams University, Cairo, Egypt
| | - Paulo F Cesar
- Department of Biomaterials and Oral Biology, Faculty of Dentistry, University of São Paulo, São Paulo, Brazil
| |
Collapse
|
49
|
Influence of the implant scan body geometry bevel feature position, implant angulation, and position on intraoral scanning accuracy: An in vitro study. J Dent 2022; 121:104122. [PMID: 35395345 DOI: 10.1016/j.jdent.2022.104122] [Citation(s) in RCA: 21] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/08/2021] [Revised: 03/31/2022] [Accepted: 04/03/2022] [Indexed: 11/21/2022] Open
Abstract
PURPOSE To assess the influence of the scan body geometry bevel position and implant angulation and position of complete-arch implant digital scans. MATERIAL AND METHODS Two definitive casts with 4 implant analogs placed parallel (P group) or angulated up to 30 degrees (NP group) were fabricated. Five subgroups were created based on the scan body geometry bevel position: facial, mesial, distal, lingual, or random (F, M, D, L, and R subgroup). Casts were digitized using a laboratory scanner (reference) (7Series Desktop Scanner) and an intraoral scanner (TRIOS 3). The implant position discrepancies between the reference and experimental scans were calculated. Data was analyzed using 3-way ANOVA and Tukey tests (α=.05). RESULTS The scan body geometry bevel position (P<.001) and the inter-implant distance (P<.001) were shown as significant predictors of the linear discrepancies obtained. The L subgroup had a significantly lower discrepancy compared with the other subgroups. Implant angulation (P<.001), the scan body geometry bevel position (P<.001), and the inter-implant distance (P<.001) were all significant predictors on the angular discrepancies obtained. CONCLUSIONS The scan body geometry bevel feature position and implant angulation and position influenced the accuracy of the IOS tested. The lingual orientation obtained significantly better accuracy values compared with the other positions. The parallel implant analog position obtained better accuracy than the angulated positions. Lastly, the implant positioned in the dental arch where the intraoral digital scan was started obtained significantly higher distortion than the contralateral implant.
Collapse
|
50
|
Arieli A, Adawi M, Masri M, Weinberg E, Beitlitum I, Pilo R, Levartovsky S. The Accuracy of Open-Tray vs. Snap on Impression Techniques in A 6-Implant Model: An In Vitro 3D Study. MATERIALS 2022; 15:ma15062103. [PMID: 35329555 PMCID: PMC8950925 DOI: 10.3390/ma15062103] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2022] [Revised: 03/04/2022] [Accepted: 03/09/2022] [Indexed: 02/04/2023]
Abstract
To compare the three-dimensional accuracy of an open-tray and two snap on impression techniques (with and without connecting the plastic caps of the snap on impression transfers) in a full arch 6-implant model, a reference acrylic resin model of the maxilla with six implants was fabricated. Prominent geometrical triangles, in the palate area, served as reference points for a digital overlap between scans. Three impression transfer techniques were evaluated and compared: open-tray direct impression (DI), snap on impression (SpO), and connected snap on impression (SpOC). Polyether impression material was used to make 30 impressions (n = 10), and the master model and all casts were digitally scanned with a laboratory optical scanner. The obtained 3D data were converted and recorded as STL files, which were imported to a 3D inspection software program. Angular deviations (buccal, occlusal and interproximal planes) between the study casts and the reference model were measured. Data were analyzed using one-way analysis of variance (ANOVA) and Tukey post hoc test, with 0.05 used as the level of significance. The 3D angular deviations from the master model revealed no significant differences between the DI and SpO impression groups, but there were significant differences in the SpOC impression group, particularly in the buccal and occlusal planes. In all groups, the 3D angular deviation between the most distal scan abutments on each side of the model was significantly different from all other areas when compared to the master model. Within the limits of this study, it is possible to conclude that the indirect closed tray snap on impression technique with unconnected plastic caps exhibited the same three-dimensional accuracies as the direct open tray technique. The indirect closed tray snap on impression technique with connected plastic caps was less accurate than either the indirect closed tray snap on impression technique with unconnected plastic caps or the direct open tray technique. In the case of full arch implant supported prostheses, inaccuracies may be expected in the most distal implants for all the three impression techniques evaluated in this study. Further in vitro and in vivo research is required.
Collapse
Affiliation(s)
- Adi Arieli
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (A.A.); (M.A.); (M.M.)
| | - Maram Adawi
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (A.A.); (M.A.); (M.M.)
| | - Mahmoud Masri
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (A.A.); (M.A.); (M.M.)
| | - Evgeny Weinberg
- Department of Periodontology and Dental Implantology, Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (E.W.); (I.B.)
- Department of Oral Biology, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel;
| | - Ilan Beitlitum
- Department of Periodontology and Dental Implantology, Maurice and Gabriela Goldschleger School of Dental Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (E.W.); (I.B.)
| | - Raphael Pilo
- Department of Oral Biology, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel;
| | - Shifra Levartovsky
- Department of Oral Rehabilitation, The Maurice and Gabriela Goldschleger School of Dental Medicine, Sackler Faculty of Medicine, Tel Aviv University, Tel Aviv 6997801, Israel; (A.A.); (M.A.); (M.M.)
- Correspondence: ; Tel.: +972-52-3515403
| |
Collapse
|