1
|
Bucak ÖF, Cinar C. The Role of ChatGPT in osteoporosis management: a comparative analysis with clinical expertise. Arch Osteoporos 2025; 20:51. [PMID: 40205011 DOI: 10.1007/s11657-025-01533-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 12/26/2024] [Accepted: 03/13/2025] [Indexed: 04/11/2025]
Abstract
This study evaluates the role of ChatGPT in osteoporosis management, demonstrating 91% diagnostic accuracy and significantly faster response times compared to clinicians. The findings highlight the potential for artificial intelligence (AI) to revolutionize clinical decision-making while emphasizing the critical need for professional oversight to ensure patient safety and comprehensive care. OBJECTIVE Osteoporosis is a progressive skeletal disease that is characterized by increased bone fragility and an increased risk of fracture. Early diagnosis and effective treatment can significantly reduce healthcare costs; however, limited access to clinical expertise represents a significant challenge to patient care. This study evaluates the diagnostic and treatment recommendations provided by natural language processing (NLP)-based AI models for osteoporosis management and compares them with those of healthcare professionals. METHODS A multicenter, cross-sectional study was conducted with the creation of 100 real scenarios from 206 patients with a diagnosis of osteoporosis. The data pertaining to bone mineral density (BMD) and the clinical parameters were subjected to analysis using ChatGPT-4.0. Thereafter, the recommendations proffered by this software were compared to those of five independent physiatrists. A statistical validation of the model's accuracy was conducted through the use of categorical distribution analysis. RESULTS ChatGPT exhibited a high degree of diagnostic accuracy, with 91% of responses being entirely accurate. It provided recommendations for both pharmacological and non-pharmacological interventions that were consistent with current clinical guidelines. Nevertheless, 8% of the responses were reported as incomplete. Furthermore, ChatGPT was able to produce diagnoses and treatment recommendations at a significantly faster rate than clinicians, while the mean answer time is 5.4 ± 2.45 min in clinicians and 2.3 ± 0.76 min in ChatGPT (p < 0.001). CONCLUSION These findings highlight the potential of AI tools like ChatGPT to improve efficiency in clinical decision-making while underscoring the necessity of collaboration with healthcare professionals to guarantee comprehensive patient care.
Collapse
Affiliation(s)
- Ömer Faruk Bucak
- Başakşehir Çam and Sakura City Hospital, Physical Medicine and Rehabilitation, University of Health Sciences, İstanbul, Turkey.
| | - Cigdem Cinar
- Department of Interventional Physiatry, Biruni University, Istanbul, Turkey
| |
Collapse
|
2
|
Xiao J, Zheng W, Wang W, Xia Q, Yan Z, Guo Q, Wang X, Nie S, Zhang S. Slice2Mesh: 3D Surface Reconstruction From Sparse Slices of Images for the Left Ventricle. IEEE TRANSACTIONS ON MEDICAL IMAGING 2025; 44:1541-1555. [PMID: 40030525 DOI: 10.1109/tmi.2024.3514869] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/05/2025]
Abstract
Cine MRI is a widely used technique to evaluate left ventricular function and motion, as it captures temporal information. However, due to the limited spatial resolution, cine MRI only provides a few sparse scans at regular positions and orientations, which poses challenges for reconstructing dense 3D cardiac structures, which is essential for better understanding the cardiac structure and motion in a dynamic 3D manner. In this study, we propose a novel learning-based 3D cardiac surface reconstruction method, Slice2Mesh, which directly predicts accurate and high-fidelity 3D meshes from sparse slices of cine MRI images under partial supervision of sparse contour points. Slice2Mesh leverages a 2D UNet to extract image features and a graph convolutional network to predict deformations from an initial template to various 3D surfaces, which enables it to produce topology-consistent meshes that can better characterize and analyze cardiac movement. We also introduce As Rigid As Possible energy in the deformation loss to preserve the intrinsic structure of the predefined template and produce realistic left ventricular shapes. We evaluated our method on 150 clinical test samples and achieved an average chamfer distance of 3.621 mm, outperforming traditional methods by approximately 2.5 mm. We also applied our method to produce 4D surface meshes from cine MRI sequences and utilized a simple SVM model on these 4D heart meshes to identify subjects with myocardial infarction, and achieved a classification sensitivity of 91.8% on 99 test subjects, including 49 abnormal patients, which implies great potential of our method for clinical use.
Collapse
|
3
|
Dou H, Virtanen S, Ravikumar N, Frangi AF. A Generative Shape Compositional Framework to Synthesize Populations of Virtual Chimeras. IEEE TRANSACTIONS ON NEURAL NETWORKS AND LEARNING SYSTEMS 2025; 36:4750-4764. [PMID: 38502618 DOI: 10.1109/tnnls.2024.3374121] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/21/2024]
Abstract
Generating virtual organ populations that capture sufficient variability while remaining plausible is essential to conduct in silico trials (ISTs) of medical devices. However, not all anatomical shapes of interest are always available for each individual in a population. The imaging examinations and modalities used can vary between subjects depending on their individualized clinical pathways. Different imaging modalities may have various fields of view and are sensitive to signals from other tissues/organs, or both. Hence, missing/partially overlapping anatomical information is often available across individuals. We introduce a generative shape model for multipart anatomical structures, learnable from sets of unpaired datasets, i.e., where each substructure in the shape assembly comes from datasets with missing or partially overlapping substructures from disjoint subjects of the same population. The proposed generative model can synthesize complete multipart shape assemblies coined virtual chimeras (VCs). We applied this framework to build VCs from databases of whole-heart shape assemblies that each contribute samples for heart substructures. Specifically, we propose a graph neural network-based generative shape compositional framework, which comprises two components, a part-aware generative shape model that captures the variability in shape observed for each structure of interest in the training population and a spatial composition network that assembles/composes the structures synthesized by the former into multipart shape assemblies (i.e., VCs). We also propose a novel self-supervised learning scheme that enables the spatial composition network to be trained with partially overlapping data and weak labels. We trained and validated our approach using shapes of cardiac structures derived from cardiac magnetic resonance (MR) images in the UK Biobank (UKBB). When trained with complete and partially overlapping data, our approach significantly outperforms a principal component analysis (PCA)-based shape model (trained with complete data) in terms of generalizability and specificity. This demonstrates the superiority of the proposed method, as the synthesized cardiac virtual populations are more plausible and capture a greater degree of shape variability than those generated by the PCA-based shape model.
Collapse
|
4
|
Nabavi S, Hashemi M, Ebrahimi Moghaddam M, Abin AA, Frangi AF. Automated cardiac coverage assessment in cardiovascular magnetic resonance imaging using an explainable recurrent 3D dual-domain convolutional network. Med Phys 2024; 51:8789-8803. [PMID: 39312585 DOI: 10.1002/mp.17411] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Revised: 07/30/2024] [Accepted: 09/01/2024] [Indexed: 09/25/2024] Open
Abstract
BACKGROUND Cardiovascular magnetic resonance (CMR) imaging has become a modality with superior power for the diagnosis and prognosis of cardiovascular diseases. One of the essential quality controls of CMR images is to investigate the complete cardiac coverage, which is necessary for the volumetric and functional assessment. PURPOSE This study examines the full cardiac coverage using a 3D dual-domain convolutional model and then improves this model using an innovative explainable salient region detection model and a recurrent architecture. METHODS Salient regions are extracted from the short-axis cine CMR stacks using a three-step proposed algorithm. Changing the architecture of the 3D dual-domain convolutional model to a recurrent one and taking advantage of the salient region detection model creates a kind of attention mechanism that leads to improved results. RESULTS The results obtained from the images of over 6200 participants of the UK Biobank population cohort study show the superiority of the proposed model over the previous studies. The dataset is the largest regarding the number of participants to control the cardiac coverage. The accuracies of the proposed model in identifying the presence/absence of basal/apical slices are 96.22% and 95.42%, respectively. CONCLUSION The proposed recurrent architecture of the 3D dual-domain convolutional model can force the model to focus on the most informative areas of the images using the extracted salient regions, which can help the model improve accuracy. The performance of the proposed fully automated model indicates that it can be used for image quality control in population cohort datasets and real-time post-imaging quality assessments. Codes are available at https://github.com/mohammadhashemii/CMR_Cardiac_Coverage_Control.
Collapse
Affiliation(s)
- Shahabedin Nabavi
- Faculty of Computer Science and Engineering, Shahid Beheshti University, Tehran, Iran
| | - Mohammad Hashemi
- Faculty of Computer Science and Engineering, Shahid Beheshti University, Tehran, Iran
| | | | - Ahmad Ali Abin
- Faculty of Computer Science and Engineering, Shahid Beheshti University, Tehran, Iran
| | - Alejandro F Frangi
- Christable Pankhurst Institute, Division of Informatics, Imaging and Data Sciences, School of Health Sciences, and Department of Computer Science, School of Engineering, The University of Manchester, Manchester, UK
- Medical Imaging Research Center (MIRC), Department of Electrical Engineering and Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium
- Alan Turing Institute, London, UK
| |
Collapse
|
5
|
Thomson RJ, Grafton‐Clarke C, Matthews G, Swoboda PP, Swift AJ, Frangi A, Petersen SE, Aung N, Garg P. Risk factors for raised left ventricular filling pressure by cardiovascular magnetic resonance: Prognostic insights. ESC Heart Fail 2024; 11:4148-4159. [PMID: 39132877 PMCID: PMC11631267 DOI: 10.1002/ehf2.15011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2024] [Revised: 06/19/2024] [Accepted: 07/15/2024] [Indexed: 08/13/2024] Open
Abstract
BACKGROUND Cardiovascular magnetic resonance (CMR) imaging shows promise in estimating pulmonary capillary wedge pressure (PCWP) non-invasively. At the population level, the prognostic role of CMR-modelled PCWP remains unknown. Furthermore, the relationship between CMR-modelled PCWP and established risk factors for cardiovascular disease has not been well characterized. OBJECTIVE The main aim of this study was to investigate the prognostic value of CMR-modelled PCWP at the population level. METHODS Employing data from the imaging substudy of the UK Biobank, a very large prospective population-based cohort study, CMR-modelled PCWP was calculated using a model incorporating left atrial volume, left ventricular mass and sex. Logistic regression explored the relationships between typical cardiovascular risk factors and raised CMR-modelled PCWP (≥15 mmHg). Cox regression was used to examine the impact of typical risk factors and CMR-modelled PCWP on heart failure (HF) and major adverse cardiovascular events (MACE). RESULTS Data from 39 163 participants were included in the study. Median age of all participants was 64 years (inter-quartile range: 58 to 70), and 47% were males. Clinical characteristics independently associated with raised CMR-modelled PCWP included hypertension [odds ratio (OR) 1.57, 95% confidence interval (CI) 1.44-1.70, P < 0.001], body mass index (BMI) [OR 1.57, 95% CI 1.52-1.62, per standard deviation (SD) increment, P < 0.001], male sex (OR 1.37, 95% CI 1.26-1.47, P < 0.001), age (OR 1.33, 95% CI 1.27-1.41, per decade increment, P < 0.001) and regular alcohol consumption (OR 1.10, 95% CI 1.02-1.19, P = 0.012). After adjusting for potential confounders, CMR-modelled PCWP was independently associated with incident HF [hazard ratio (HR) 2.91, 95% CI 2.07-4.07, P < 0.001] and MACE (HR 1.48, 95% CI 1.16-1.89, P = 0.002). CONCLUSIONS Raised CMR-modelled PCWP is an independent risk factor for incident HF and MACE. CMR-modelled PCWP should be incorporated into routine CMR reports to guide HF diagnosis and further management.
Collapse
Affiliation(s)
- Ross J. Thomson
- William Harvey Research Institute, NIHR Barts Biomedical Research CentreQueen Mary University of LondonLondonUK
- Barts Heart Centre, St Bartholomew's Hospital, Barts NHS Trust, West SmithfieldLondonUK
| | - Ciaran Grafton‐Clarke
- Norwich Medical SchoolUniversity of East AngliaNorwichUK
- Norfolk and Norwich University HospitalsNorwichUK
| | - Gareth Matthews
- Norwich Medical SchoolUniversity of East AngliaNorwichUK
- Norfolk and Norwich University HospitalsNorwichUK
| | - Peter P. Swoboda
- The Institute of Cardiovascular and Metabolic MedicineUniversity of LeedsLeedsUK
| | - Andrew J. Swift
- Department of Infection, Immunity and Cardiovascular DiseaseThe University of SheffieldSheffieldUK
| | | | - Steffen E. Petersen
- William Harvey Research Institute, NIHR Barts Biomedical Research CentreQueen Mary University of LondonLondonUK
- Barts Heart Centre, St Bartholomew's Hospital, Barts NHS Trust, West SmithfieldLondonUK
- Health Data Research UKLondonUK
- Alan Turing InstituteLondonUK
| | - Nay Aung
- William Harvey Research Institute, NIHR Barts Biomedical Research CentreQueen Mary University of LondonLondonUK
- Barts Heart Centre, St Bartholomew's Hospital, Barts NHS Trust, West SmithfieldLondonUK
| | - Pankaj Garg
- Barts Heart Centre, St Bartholomew's Hospital, Barts NHS Trust, West SmithfieldLondonUK
- Norwich Medical SchoolUniversity of East AngliaNorwichUK
- Norfolk and Norwich University HospitalsNorwichUK
| |
Collapse
|
6
|
Sanghvi MM, Lima JAC, Bluemke DA, Petersen SE. A history of cardiovascular magnetic resonance imaging in clinical practice and population science. Front Cardiovasc Med 2024; 11:1393896. [PMID: 38707888 PMCID: PMC11066259 DOI: 10.3389/fcvm.2024.1393896] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/29/2024] [Accepted: 04/08/2024] [Indexed: 05/07/2024] Open
Abstract
Cardiovascular magnetic resonance (CMR) imaging has become an invaluable clinical and research tool. Starting from the discovery of nuclear magnetic resonance, this article provides a brief overview of the key developments that have led to CMR as it is today, and how it became the modality of choice for large-scale population studies.
Collapse
Affiliation(s)
- Mihir M. Sanghvi
- William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
- Barts Heart Centre, Barts Health NHS Trust, London, United Kingdom
| | - João A. C. Lima
- Division of Cardiology, Department of Medicine, Johns Hopkins University, Baltimore, MD, United States
- Department of Radiology, Johns Hopkins University, Baltimore, MD, United States
| | - David A. Bluemke
- Department of Radiology, University of Wisconsin School of Medicine and Public Heath, Madison, WI, United States
| | - Steffen E. Petersen
- William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
- Barts Heart Centre, Barts Health NHS Trust, London, United Kingdom
| |
Collapse
|
7
|
Bonazzola R, Ferrante E, Ravikumar N, Xia Y, Keavney B, Plein S, Syeda-Mahmood T, Frangi AF. Unsupervised ensemble-based phenotyping enhances discoverability of genes related to left-ventricular morphology. NAT MACH INTELL 2024; 6:291-306. [PMID: 38523678 PMCID: PMC10957472 DOI: 10.1038/s42256-024-00801-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/07/2023] [Accepted: 01/25/2024] [Indexed: 03/26/2024]
Abstract
Recent genome-wide association studies have successfully identified associations between genetic variants and simple cardiac morphological parameters derived from cardiac magnetic resonance images. However, the emergence of large databases, including genetic data linked to cardiac magnetic resonance facilitates the investigation of more nuanced patterns of cardiac shape variability than those studied so far. Here we propose a framework for gene discovery coined unsupervised phenotype ensembles. The unsupervised phenotype ensemble builds a redundant yet highly expressive representation by pooling a set of phenotypes learnt in an unsupervised manner, using deep learning models trained with different hyperparameters. These phenotypes are then analysed via genome-wide association studies, retaining only highly confident and stable associations across the ensemble. We applied our approach to the UK Biobank database to extract geometric features of the left ventricle from image-derived three-dimensional meshes. We demonstrate that our approach greatly improves the discoverability of genes that influence left ventricle shape, identifying 49 loci with study-wide significance and 25 with suggestive significance. We argue that our approach would enable more extensive discovery of gene associations with image-derived phenotypes for other organs or image modalities.
Collapse
Affiliation(s)
- Rodrigo Bonazzola
- Centre for Computational Imaging and Simulation Technologies in Biomedicine, School of Computing and School of Medicine, University of Leeds, Leeds, UK
- Leeds Institute of Cardiovascular and Metabolic Medicine, School of Medicine, University of Leeds, Leeds, UK
| | - Enzo Ferrante
- Research Institute for Signals, Systems and Computational Intelligence, sinc(i), FICH-UNL/CONICET, Santa Fe, Argentina
| | - Nishant Ravikumar
- Centre for Computational Imaging and Simulation Technologies in Biomedicine, School of Computing and School of Medicine, University of Leeds, Leeds, UK
- Leeds Institute of Cardiovascular and Metabolic Medicine, School of Medicine, University of Leeds, Leeds, UK
| | - Yan Xia
- Centre for Computational Imaging and Simulation Technologies in Biomedicine, School of Computing and School of Medicine, University of Leeds, Leeds, UK
- Leeds Institute of Cardiovascular and Metabolic Medicine, School of Medicine, University of Leeds, Leeds, UK
| | - Bernard Keavney
- Division of Cardiovascular Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
- Manchester University NHS Foundation Trust, Manchester Academic Health Science Centre, Manchester, UK
- NIHR Manchester Biomedical Research Centre, Manchester Academic Health Science Centre, Manchester, UK
| | - Sven Plein
- Leeds Institute of Cardiovascular and Metabolic Medicine, School of Medicine, University of Leeds, Leeds, UK
| | | | - Alejandro F. Frangi
- NIHR Manchester Biomedical Research Centre, Manchester Academic Health Science Centre, Manchester, UK
- Division of Informatics, Imaging and Data Sciences, School of Health Sciences, Faculty of Biology, Medicine and Health, University of Manchester, Manchester, UK
- Department of Computer Science, School of Engineering, Faculty of Science and Engineering, University of Manchester, Manchester, UK
- Medical Imaging Research Center (MIRC), University Hospital Gasthuisberg. Cardiovascular Sciences and Electrical Engineering Departments, KU Leuven, Leuven, Belgium
- Alan Turing Institute, London, UK
| |
Collapse
|
8
|
Machado I, Puyol-Anton E, Hammernik K, Cruz G, Ugurlu D, Olakorede I, Oksuz I, Ruijsink B, Castelo-Branco M, Young A, Prieto C, Schnabel J, King A. A Deep Learning-Based Integrated Framework for Quality-Aware Undersampled Cine Cardiac MRI Reconstruction and Analysis. IEEE Trans Biomed Eng 2024; 71:855-865. [PMID: 37782583 DOI: 10.1109/tbme.2023.3321431] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/04/2023]
Abstract
Cine cardiac magnetic resonance (CMR) imaging is considered the gold standard for cardiac function evaluation. However, cine CMR acquisition is inherently slow and in recent decades considerable effort has been put into accelerating scan times without compromising image quality or the accuracy of derived results. In this article, we present a fully-automated, quality-controlled integrated framework for reconstruction, segmentation and downstream analysis of undersampled cine CMR data. The framework produces high quality reconstructions and segmentations, leading to undersampling factors that are optimised on a scan-by-scan basis. This results in reduced scan times and automated analysis, enabling robust and accurate estimation of functional biomarkers. To demonstrate the feasibility of the proposed approach, we perform simulations of radial k-space acquisitions using in-vivo cine CMR data from 270 subjects from the UK Biobank (with synthetic phase) and in-vivo cine CMR data from 16 healthy subjects (with real phase). The results demonstrate that the optimal undersampling factor varies for different subjects by approximately 1 to 2 seconds per slice. We show that our method can produce quality-controlled images in a mean scan time reduced from 12 to 4 seconds per slice, and that image quality is sufficient to allow clinically relevant parameters to be automatically estimated to lie within 5% mean absolute difference.
Collapse
|
9
|
Wang J, Zhang N, Wang S, Liang W, Zhao H, Xia W, Zhu J, Zhang Y, Zhang W, Chai S. AI approach to biventricular function assessment in cine-MRI: an ultra-small training dataset and multivendor study. Phys Med Biol 2023; 68:245025. [PMID: 37918023 DOI: 10.1088/1361-6560/ad0903] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2023] [Accepted: 11/01/2023] [Indexed: 11/04/2023]
Abstract
Objective. It was a great challenge to train an excellent and generalized model on an ultra-small data set composed of multi-orientation cardiac cine magnetic resonance imaging (MRI) images. We try to develop a 3D deep learning method based on an ultra-small training data set from muti-orientation cine MRI images and assess its performance of automated biventricular structure segmentation and function assessment in multivendor.Approach. We completed the training and testing of our deep learning networks using only heart datasets of 150 cases (90 cases for training and 60 cases for testing). This datasets were obtained from three different MRI vendors and each subject included two phases of the cardiac cycle and three cine sequences. A 3D deep learning algorithm combining Transformers and U-Net was trained. The performance of the segmentation was evaluated using the Dice metric and Hausdorff distance (HD). Based on this, the manual and automatic results of cardiac function parameters were compared with Pearson correlation, intraclass correlation coefficient (ICC) and Bland-Altman analysis in multivendor.Main results. The results show that the average Dice of 0.92, 0.92, 0.94 and HD95 of 2.50, 1.36, 1.37 for three sequences. The automatic and manual results of seven parameters were excellently correlated with the lowestr2 value of 0.824 and the highest of 0.983. The ICC (0.908-0.989,P< 0.001) showed that the results were highly consistent. Bland-Altman with a 95% limit of agreement showed there was no significant difference except for the difference in RVESV (P= 0.005) and LVM (P< 0.001).Significance. The model had high accuracy in segmentation and excellent correlation and consistency in function assessment. It provides a fast and effective method for studying cardiac MRI and heart disease.
Collapse
Affiliation(s)
- Jing Wang
- School of Information Science and Engineering, University of Jinan, People's Republic of China
| | - Nan Zhang
- Department of Radiology, Beijing Anzhen Hospital, Capital Medical University, People's Republic of China
| | - Shuyu Wang
- Department of Electric Information Engineering, Shandong Youth University of Political Science, People's Republic of China
| | - Wei Liang
- Department of Ecological Environment Statistics, Department of ecological environment of Shandong, People's Republic of China
| | - Haiyue Zhao
- Department of Electric Information Engineering, Shandong Youth University of Political Science, People's Republic of China
| | - Weili Xia
- Department of Science and Education, Shandong Mental Health Center, People's Republic of China
| | - Jianlei Zhu
- Department of Neuromodulation Center, Shandong Mental Health Center, People's Republic of China
| | - Yan Zhang
- Department of Radiology, Shandong Mental Health Center, People's Republic of China
| | - Wei Zhang
- Department of Medical Ultrasound, The First Affiliated Hospital of Shandong First Medical University & Shandong Provincial Qianfoshan Hospital, People's Republic of China
| | - Senchun Chai
- Department of Automation, School of automation, Beijing Institute of Technology, People's Republic of China
| |
Collapse
|
10
|
Hu H, Pan N, Frangi AF. Fully Automatic initialization and segmentation of left and right ventricles for large-scale cardiac MRI using a deeply supervised network and 3D-ASM. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE 2023; 240:107679. [PMID: 37364366 DOI: 10.1016/j.cmpb.2023.107679] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 06/12/2023] [Accepted: 06/13/2023] [Indexed: 06/28/2023]
Abstract
BACKGROUND AND OBJECTIVE The sheer volume of data generated by population imaging studies is unparalleled by current capabilities to extract objective and quantitative cardiac phenotypes; subjective and time-consuming manual image analysis remains the gold standard. Automated image analytics to compute quantitative imaging biomarkers of cardiac function are desperately needed. Data volumes and their variability pose a challenge to most state-of-the-art methods for endo- and epicardial contours, which lack robustness when applied to very large datasets. Our aim is to develop an analysis pipeline for the automatic quantification of cardiac function from cine magnetic resonance imaging data. METHOD This work adopt 4,638 cardiac MRI cases coming from UK Biobank with ground truth available for left and RV contours. A hybrid and robust algorithm is proposed to improve the accuracy of automatic left and right ventricle segmentation by harnessing the localization accuracy of deep learning and the morphological accuracy of 3D-ASM (three-dimensional active shape models). The contributions of this paper are three-fold. First, a fully automatic method is proposed for left and right ventricle initialization and cardiac MRI segmentation by taking full advantage of spatiotemporal constraint. Second, a deeply supervised network is introduced to train and segment the heart. Third, the 3D-ASM image search procedure is improved by combining image intensity models with convolutional neural network (CNN) derived distance maps improving endo- and epicardial edge localization. RESULTS The proposed architecture outperformed the state of the art for cardiac MRI segmentation from UK Biobank. The statistics of RV landmarks detection errors for Triscuspid valve and RV apex are 4.17 mm and 5.58 mm separately. The overlap metric, mean contour distance, Hausdorff distance and cardiac functional parameters are calculated for the LV (Left Ventricle) and RV (Right Ventricle) contour segmentation. Bland-Altman analysis for clinical parameters shows that the results from our automated image analysis pipelines are in good agreement with results from expert manual analysis. CONCLUSIONS Our hybrid scheme combines deep learning and statistical shape modeling for automatic segmentation of the LV/RV from cardiac MRI datasets is effective and robust and can compute cardiac functional indexes from population imaging.
Collapse
Affiliation(s)
- Huaifei Hu
- College of Biomedical Engineering, South-Central Minzu University, Wuhan 430074, China; Hubei Key Laboratory of Medical Information Analysis and Tumor Diagnosis & Treatment, Wuhan 430074, China; Key Laboratory of Cognitive Science, State Ethnic Affairs Commission, Wuhan 430074, China
| | - Ning Pan
- College of Biomedical Engineering, South-Central Minzu University, Wuhan 430074, China; Hubei Key Laboratory of Medical Information Analysis and Tumor Diagnosis & Treatment, Wuhan 430074, China; Key Laboratory of Cognitive Science, State Ethnic Affairs Commission, Wuhan 430074, China.
| | - Alejandro F Frangi
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK; Biomedical Imaging Sciences Department, Leeds Institute for Cardiovascular and Metabolic Medicine (LICAMM), School of Medicine, University of Leeds, Leeds, UK; Medical Imaging Research Centre, Cardiovascular Sciences Department, KU Leuven, Leuven, Belgium; Medical Imaging Research Centre, Electrical Engineering Department, KU Leuven, Leuven, Belgium.
| |
Collapse
|
11
|
Pujadas ER, Raisi-Estabragh Z, Szabo L, McCracken C, Morcillo CI, Campello VM, Martín-Isla C, Atehortua AM, Vago H, Merkely B, Maurovich-Horvat P, Harvey NC, Neubauer S, Petersen SE, Lekadir K. Prediction of incident cardiovascular events using machine learning and CMR radiomics. Eur Radiol 2023; 33:3488-3500. [PMID: 36512045 PMCID: PMC10121487 DOI: 10.1007/s00330-022-09323-z] [Citation(s) in RCA: 9] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2022] [Revised: 09/28/2022] [Accepted: 11/28/2022] [Indexed: 12/15/2022]
Abstract
OBJECTIVES Evaluation of the feasibility of using cardiovascular magnetic resonance (CMR) radiomics in the prediction of incident atrial fibrillation (AF), heart failure (HF), myocardial infarction (MI), and stroke using machine learning techniques. METHODS We identified participants from the UK Biobank who experienced incident AF, HF, MI, or stroke during the continuous longitudinal follow-up. The CMR indices and the vascular risk factors (VRFs) as well as the CMR images were obtained for each participant. Three-segmented regions of interest (ROIs) were computed: right ventricle cavity, left ventricle (LV) cavity, and LV myocardium in end-systole and end-diastole phases. Radiomics features were extracted from the 3D volumes of the ROIs. Seven integrative models were built for each incident cardiovascular disease (CVD) as an outcome. Each model was built with VRF, CMR indices, and radiomics features and a combination of them. Support vector machine was used for classification. To assess the model performance, the accuracy, sensitivity, specificity, and AUC were reported. RESULTS AF prediction model using the VRF+CMR+Rad model (accuracy: 0.71, AUC 0.76) obtained the best result. However, the AUC was similar to the VRF+Rad model. HF showed the most significant improvement with the inclusion of CMR metrics (VRF+CMR+Rad: 0.79, AUC 0.84). Moreover, adding only the radiomics features to the VRF reached an almost similarly good performance (VRF+Rad: accuracy 0.77, AUC 0.83). Prediction models looking into incident MI and stroke reached slightly smaller improvement. CONCLUSIONS Radiomics features may provide incremental predictive value over VRF and CMR indices in the prediction of incident CVDs. KEY POINTS • Prediction of incident atrial fibrillation, heart failure, stroke, and myocardial infarction using machine learning techniques. • CMR radiomics, vascular risk factors, and standard CMR indices will be considered in the machine learning models. • The experiments show that radiomics features can provide incremental predictive value over VRF and CMR indices in the prediction of incident cardiovascular diseases.
Collapse
Affiliation(s)
- Esmeralda Ruiz Pujadas
- Artificial Intelligence in Medicine Lab (BCN-AIM), Departament de Matemàtiques i Informàtica, Universitat de Barcelona, Barcelona, Spain.
| | - Zahra Raisi-Estabragh
- William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London, EC1M 6BQ, UK
- Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK
| | - Liliana Szabo
- William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London, EC1M 6BQ, UK
- Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK
- Semmelweis University Heart and Vascular Center, Budapest, Hungary
| | - Celeste McCracken
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, National Institute for Health Research Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, OX3 9DU, UK
| | - Cristian Izquierdo Morcillo
- Artificial Intelligence in Medicine Lab (BCN-AIM), Departament de Matemàtiques i Informàtica, Universitat de Barcelona, Barcelona, Spain
| | - Víctor M Campello
- Artificial Intelligence in Medicine Lab (BCN-AIM), Departament de Matemàtiques i Informàtica, Universitat de Barcelona, Barcelona, Spain
| | - Carlos Martín-Isla
- Artificial Intelligence in Medicine Lab (BCN-AIM), Departament de Matemàtiques i Informàtica, Universitat de Barcelona, Barcelona, Spain
| | - Angelica M Atehortua
- Artificial Intelligence in Medicine Lab (BCN-AIM), Departament de Matemàtiques i Informàtica, Universitat de Barcelona, Barcelona, Spain
| | - Hajnalka Vago
- Semmelweis University Heart and Vascular Center, Budapest, Hungary
| | - Bela Merkely
- Semmelweis University Heart and Vascular Center, Budapest, Hungary
| | | | - Nicholas C Harvey
- MRC Lifecourse Epidemiology Centre, University of Southampton, Southampton, UK
- NIHR Southampton Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Stefan Neubauer
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, National Institute for Health Research Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, OX3 9DU, UK
| | - Steffen E Petersen
- William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London, EC1M 6BQ, UK
- Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK
- Health Data Research UK, London, UK
- Alan Turing Institute, London, UK
| | - Karim Lekadir
- Artificial Intelligence in Medicine Lab (BCN-AIM), Departament de Matemàtiques i Informàtica, Universitat de Barcelona, Barcelona, Spain.
| |
Collapse
|
12
|
Al Khalil Y, Amirrajab S, Lorenz C, Weese J, Pluim J, Breeuwer M. Reducing segmentation failures in cardiac MRI via late feature fusion and GAN-based augmentation. Comput Biol Med 2023; 161:106973. [PMID: 37209615 DOI: 10.1016/j.compbiomed.2023.106973] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Revised: 04/05/2023] [Accepted: 04/22/2023] [Indexed: 05/22/2023]
Abstract
Cardiac magnetic resonance (CMR) image segmentation is an integral step in the analysis of cardiac function and diagnosis of heart related diseases. While recent deep learning-based approaches in automatic segmentation have shown great promise to alleviate the need for manual segmentation, most of these are not applicable to realistic clinical scenarios. This is largely due to training on mainly homogeneous datasets, without variation in acquisition, which typically occurs in multi-vendor and multi-site settings, as well as pathological data. Such approaches frequently exhibit a degradation in prediction performance, particularly on outlier cases commonly associated with difficult pathologies, artifacts and extensive changes in tissue shape and appearance. In this work, we present a model aimed at segmenting all three cardiac structures in a multi-center, multi-disease and multi-view scenario. We propose a pipeline, addressing different challenges with segmentation of such heterogeneous data, consisting of heart region detection, augmentation through image synthesis and a late-fusion segmentation approach. Extensive experiments and analysis demonstrate the ability of the proposed approach to tackle the presence of outlier cases during both training and testing, allowing for better adaptation to unseen and difficult examples. Overall, we show that the effective reduction of segmentation failures on outlier cases has a positive impact on not only the average segmentation performance, but also on the estimation of clinical parameters, leading to a better consistency in derived metrics.
Collapse
Affiliation(s)
- Yasmina Al Khalil
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands.
| | - Sina Amirrajab
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | | | | | - Josien Pluim
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Marcel Breeuwer
- Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands; Philips Healthcare, MR R&D - Clinical Science, Best, The Netherlands
| |
Collapse
|
13
|
De Santi LA, Meloni A, Santarelli MF, Pistoia L, Spasiano A, Casini T, Putti MC, Cuccia L, Cademartiri F, Positano V. Left Ventricle Detection from Cardiac Magnetic Resonance Relaxometry Images Using Visual Transformer. SENSORS (BASEL, SWITZERLAND) 2023; 23:3321. [PMID: 36992032 PMCID: PMC10052975 DOI: 10.3390/s23063321] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/02/2023] [Revised: 03/16/2023] [Accepted: 03/20/2023] [Indexed: 06/19/2023]
Abstract
Left Ventricle (LV) detection from Cardiac Magnetic Resonance (CMR) imaging is a fundamental step, preliminary to myocardium segmentation and characterization. This paper focuses on the application of a Visual Transformer (ViT), a novel neural network architecture, to automatically detect LV from CMR relaxometry sequences. We implemented an object detector based on the ViT model to identify LV from CMR multi-echo T2* sequences. We evaluated performances differentiated by slice location according to the American Heart Association model using 5-fold cross-validation and on an independent dataset of CMR T2*, T2, and T1 acquisitions. To the best of our knowledge, this is the first attempt to localize LV from relaxometry sequences and the first application of ViT for LV detection. We collected an Intersection over Union (IoU) index of 0.68 and a Correct Identification Rate (CIR) of blood pool centroid of 0.99, comparable with other state-of-the-art methods. IoU and CIR values were significantly lower in apical slices. No significant differences in performances were assessed on independent T2* dataset (IoU = 0.68, p = 0.405; CIR = 0.94, p = 0.066). Performances were significantly worse on the T2 and T1 independent datasets (T2: IoU = 0.62, CIR = 0.95; T1: IoU = 0.67, CIR = 0.98), but still encouraging considering the different types of acquisition. This study confirms the feasibility of the application of ViT architectures in LV detection and defines a benchmark for relaxometry imaging.
Collapse
Affiliation(s)
- Lisa Anita De Santi
- Department of Information Engineering, University of Pisa, 56122 Pisa, Italy;
- U.O.C. Bioingegneria, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy;
| | - Antonella Meloni
- U.O.C. Bioingegneria, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy;
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (L.P.)
| | | | - Laura Pistoia
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (L.P.)
| | - Anna Spasiano
- Unità Operativa Semplice Dipartimentale Malattie Rare del Globulo Rosso, Azienda Ospedaliera di Rilievo Nazionale “A. Cardarelli”, 80131 Napoli, Italy
| | - Tommaso Casini
- Centro Talassemie ed Emoglobinopatie, Ospedale “Meyer”, 50139 Firenze, Italy
| | - Maria Caterina Putti
- Clinica di Emato-Oncologia Pediatrica, Dipartimento di Salute della Donna e del Bambino, Azienda Ospedale Università, 35128 Padova, Italy
| | - Liana Cuccia
- Unità Operativa Complessa Ematologia con Talassemia, ARNAS Civico “Benfratelli-Di Cristina”, 90127 Palermo, Italy
| | - Filippo Cademartiri
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (L.P.)
| | - Vincenzo Positano
- U.O.C. Bioingegneria, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy;
- Department of Radiology, Fondazione G. Monasterio CNR-Regione Toscana, 56124 Pisa, Italy; (L.P.)
| |
Collapse
|
14
|
Ma Y, Qi M, Li K, Wang Y, Ren F, Gao D. Conventional and genetic associations between resting heart rate, cardiac morphology and function as assessed by magnetic resonance imaging: Insights from the UK biobank population study. Front Cardiovasc Med 2023; 10:1110231. [PMID: 37008308 PMCID: PMC10063878 DOI: 10.3389/fcvm.2023.1110231] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2022] [Accepted: 02/28/2023] [Indexed: 03/19/2023] Open
Abstract
AimTo examine the direction, strength and causality of the associations of resting heart rate (RHR) with cardiac morphology and function in 20,062 UK Biobank participants.Methods and resultsParticipants underwent cardiac magnetic resonance (CMR) and we extracted CMR biventricular structural and functional metrics using automated pipelines. Multivariate linear regression adjusted for the main cardiovascular risk factors and Two-sample Mendelian Randomization analyses were performed to assess the potential relationship, grouped by heart rate and stratified by sex. Each 10 beats per minute increase in RHR was linked with smaller ventricular structure (lower biventricular end-diastolic volume and end-systolic volume), poorer left ventricular (LV) function (lower LV ejection fraction, global longitude strain and global function index) and unhealthy pattern of LV remodeling (higher values of myocardial contraction fraction), but there is no statistical difference in LV wall thickness. These trends are more pronounced among males and consistent with the causal effect direction of genetic variants interpretation. These observations reflect that RHR has an independent and broad impact on LV remodeling, however, genetically-predicted RHR is not statistically related to heart failure.ConclusionWe demonstrate higher RHR cause smaller ventricular chamber volume, poorer systolic function and unhealthy cardiac remodeling pattern. Our findings provide effective evidence for the potential mechanism of cardiac remodeling and help to explore the potential scope or benefit of intervention.
Collapse
Affiliation(s)
- Yao Ma
- Cardiology Diseases Department, Xi’an Jiaotong University Second Affiliated Hospital, Xi’an, China
| | - Mengyao Qi
- Cardiology Diseases Department, Xi’an Jiaotong University Second Affiliated Hospital, Xi’an, China
| | - Kexin Li
- Cardiology Diseases Department, Xi’an Jiaotong University Second Affiliated Hospital, Xi’an, China
| | - Yuan Wang
- Cardiology Diseases Department, Xi’an Jiaotong University Second Affiliated Hospital, Xi’an, China
| | - Fuxian Ren
- Department of Cardiology, Meishan Brach of the Third Affiliated Hospital, Yanan University School of Medical, Meishan, China
- Correspondence: Dengfeng Gao Fuxian Ren
| | - Dengfeng Gao
- Cardiology Diseases Department, Xi’an Jiaotong University Second Affiliated Hospital, Xi’an, China
- Correspondence: Dengfeng Gao Fuxian Ren
| |
Collapse
|
15
|
Bourfiss M, Sander J, de Vos BD, Te Riele ASJM, Asselbergs FW, Išgum I, Velthuis BK. Towards automatic classification of cardiovascular magnetic resonance Task Force Criteria for diagnosis of arrhythmogenic right ventricular cardiomyopathy. Clin Res Cardiol 2023; 112:363-378. [PMID: 36066609 PMCID: PMC9998324 DOI: 10.1007/s00392-022-02088-x] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/20/2022] [Accepted: 08/16/2022] [Indexed: 11/03/2022]
Abstract
BACKGROUND Arrhythmogenic right ventricular cardiomyopathy (ARVC) is diagnosed according to the Task Force Criteria (TFC) in which cardiovascular magnetic resonance (CMR) imaging plays an important role. Our study aims to apply an automatic deep learning-based segmentation for right and left ventricular CMR assessment and evaluate this approach for classification of the CMR TFC. METHODS We included 227 subjects suspected of ARVC who underwent CMR. Subjects were classified into (1) ARVC patients fulfilling TFC; (2) at-risk family members; and (3) controls. To perform automatic segmentation, a Bayesian Dilated Residual Neural Network was trained and tested. Performance of automatic versus manual segmentation was assessed using Dice-coefficient and Hausdorff distance. Since automatic segmentation is most challenging in basal slices, manual correction of the automatic segmentation in the most basal slice was simulated (automatic-basal). CMR TFC calculated using manual and automatic-basal segmentation were compared using Cohen's Kappa (κ). RESULTS Automatic segmentation was trained on CMRs of 70 subjects (39.6 ± 18.1 years, 47% female) and tested on 157 subjects (36.9 ± 17.6 years, 59% female). Dice-coefficient and Hausdorff distance showed good agreement between manual and automatic segmentations (≥ 0.89 and ≤ 10.6 mm, respectively) which further improved after simulated correction of the most basal slice (≥ 0.92 and ≤ 9.2 mm, p < 0.001). Pearson correlation of volumetric and functional CMR measurements was good to excellent (automatic (r = 0.78-0.99, p < 0.001) and automatic-basal (r = 0.88-0.99, p < 0.001) measurements). CMR TFC classification using automatic-basal segmentations was comparable to manual segmentations (κ 0.98 ± 0.02) with comparable diagnostic performance. CONCLUSIONS Combining automatic segmentation of CMRs with correction of the most basal slice results in accurate CMR TFC classification of subjects suspected of ARVC.
Collapse
Affiliation(s)
- Mimount Bourfiss
- Department of Medicine, Division of Cardiology, University Medical Center Utrecht, Utrecht University, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.
| | - Jörg Sander
- Department of Biomedical Engineering and Physics, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands
| | - Bob D de Vos
- Department of Biomedical Engineering and Physics, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.,Amsterdam Cardiovascular Sciences, Heart Failure & Arrhythmias, Amsterdam, The Netherlands
| | - Anneline S J M Te Riele
- Department of Medicine, Division of Cardiology, University Medical Center Utrecht, Utrecht University, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.,Netherlands Heart Institute, Utrecht, The Netherlands
| | - Folkert W Asselbergs
- Department of Medicine, Division of Cardiology, University Medical Center Utrecht, Utrecht University, Heidelberglaan 100, 3584 CX, Utrecht, The Netherlands.,Institute of Cardiovascular Science, Faculty of Population Health Sciences, University College London, London, UK.,Health Data Research UK and Institute of Health Informatics, University College London, London, UK
| | - Ivana Išgum
- Department of Biomedical Engineering and Physics, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.,Amsterdam Cardiovascular Sciences, Heart Failure & Arrhythmias, Amsterdam, The Netherlands.,Department of Radiology and Nuclear Medicine, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands
| | - Birgitta K Velthuis
- Department of Radiology, University Medical Center Utrecht, Utrecht University, Utrecht, The Netherlands
| |
Collapse
|
16
|
Automated imaging-based abdominal organ segmentation and quality control in 20,000 participants of the UK Biobank and German National Cohort Studies. Sci Rep 2022; 12:18733. [PMID: 36333523 PMCID: PMC9636393 DOI: 10.1038/s41598-022-23632-9] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Accepted: 11/02/2022] [Indexed: 11/06/2022] Open
Abstract
Large epidemiological studies such as the UK Biobank (UKBB) or German National Cohort (NAKO) provide unprecedented health-related data of the general population aiming to better understand determinants of health and disease. As part of these studies, Magnetic Resonance Imaging (MRI) is performed in a subset of participants allowing for phenotypical and functional characterization of different organ systems. Due to the large amount of imaging data, automated image analysis is required, which can be performed using deep learning methods, e. g. for automated organ segmentation. In this paper we describe a computational pipeline for automated segmentation of abdominal organs on MRI data from 20,000 participants of UKBB and NAKO and provide results of the quality control process. We found that approx. 90% of data sets showed no relevant segmentation errors while relevant errors occurred in a varying proportion of data sets depending on the organ of interest. Image-derived features based on automated organ segmentations showed relevant deviations of varying degree in the presence of segmentation errors. These results show that large-scale, deep learning-based abdominal organ segmentation on MRI data is feasible with overall high accuracy, but visual quality control remains an important step ensuring the validity of down-stream analyses in large epidemiological imaging studies.
Collapse
|
17
|
Xia Y, Chen X, Ravikumar N, Kelly C, Attar R, Aung N, Neubauer S, Petersen SE, Frangi AF. Automatic 3D+t four-chamber CMR quantification of the UK biobank: integrating imaging and non-imaging data priors at scale. Med Image Anal 2022; 80:102498. [PMID: 35665663 DOI: 10.1016/j.media.2022.102498] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2020] [Revised: 05/14/2022] [Accepted: 05/24/2022] [Indexed: 11/18/2022]
Abstract
Accurate 3D modelling of cardiac chambers is essential for clinical assessment of cardiac volume and function, including structural, and motion analysis. Furthermore, to study the correlation between cardiac morphology and other patient information within a large population, it is necessary to automatically generate cardiac mesh models of each subject within the population. In this study, we introduce MCSI-Net (Multi-Cue Shape Inference Network), where we embed a statistical shape model inside a convolutional neural network and leverage both phenotypic and demographic information from the cohort to infer subject-specific reconstructions of all four cardiac chambers in 3D. In this way, we leverage the ability of the network to learn the appearance of cardiac chambers in cine cardiac magnetic resonance (CMR) images, and generate plausible 3D cardiac shapes, by constraining the prediction using a shape prior, in the form of the statistical modes of shape variation learned a priori from a subset of the population. This, in turn, enables the network to generalise to samples across the entire population. To the best of our knowledge, this is the first work that uses such an approach for patient-specific cardiac shape generation. MCSI-Net is capable of producing accurate 3D shapes using just a fraction (about 23% to 46%) of the available image data, which is of significant importance to the community as it supports the acceleration of CMR scan acquisitions. Cardiac MR images from the UK Biobank were used to train and validate the proposed method. We also present the results from analysing 40,000 subjects of the UK Biobank at 50 time-frames, totalling two million image volumes. Our model can generate more globally consistent heart shape than that of manual annotations in the presence of inter-slice motion and shows strong agreement with the reference ranges for cardiac structure and function across cardiac ventricles and atria.
Collapse
Affiliation(s)
- Yan Xia
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK; Biomedical Imaging Department, Leeds Institute for Cardiovascular and Metabolic Medicine (LICAMM), School of Medicine, University of Leeds, Leeds, UK
| | - Xiang Chen
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK
| | - Nishant Ravikumar
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK
| | - Christopher Kelly
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK
| | - Rahman Attar
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK; Biomedical Imaging Department, Leeds Institute for Cardiovascular and Metabolic Medicine (LICAMM), School of Medicine, University of Leeds, Leeds, UK
| | - Nay Aung
- William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, London, UK; Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, UK
| | - Stefan Neubauer
- Oxford Centre for Clinical Magnetic Resonance Research (OCMR), Division of Cardiovascular Medicine, University of Oxford, John Radcliffe Hospital, Oxford, UK
| | - Steffen E Petersen
- William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, London, UK; Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, UK
| | - Alejandro F Frangi
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK; Biomedical Imaging Department, Leeds Institute for Cardiovascular and Metabolic Medicine (LICAMM), School of Medicine, University of Leeds, Leeds, UK; Department of Cardiovascular Sciences, KU Leuven, Leuven, Belgium; Department of Electrical Engineering, KU Leuven, Leuven, Belgium; Alan Turing Institute, London, UK.
| |
Collapse
|
18
|
Raisi-Estabragh Z, Salih A, Gkontra P, Atehortúa A, Radeva P, Boscolo Galazzo I, Menegaz G, Harvey NC, Lekadir K, Petersen SE. Estimation of biological heart age using cardiovascular magnetic resonance radiomics. Sci Rep 2022; 12:12805. [PMID: 35896705 PMCID: PMC9329281 DOI: 10.1038/s41598-022-16639-9] [Citation(s) in RCA: 19] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Accepted: 07/13/2022] [Indexed: 11/08/2022] Open
Abstract
We developed a novel interpretable biological heart age estimation model using cardiovascular magnetic resonance radiomics measures of ventricular shape and myocardial character. We included 29,996 UK Biobank participants without cardiovascular disease. Images were segmented using an automated analysis pipeline. We extracted 254 radiomics features from the left ventricle, right ventricle, and myocardium of each study. We then used Bayesian ridge regression with tenfold cross-validation to develop a heart age estimation model using the radiomics features as the model input and chronological age as the model output. We examined associations of radiomics features with heart age in men and women, observing sex-differential patterns. We subtracted actual age from model estimated heart age to calculate a "heart age delta", which we considered as a measure of heart aging. We performed a phenome-wide association study of 701 exposures with heart age delta. The strongest correlates of heart aging were measures of obesity, adverse serum lipid markers, hypertension, diabetes, heart rate, income, multimorbidity, musculoskeletal health, and respiratory health. This technique provides a new method for phenotypic assessment relating to cardiovascular aging; further studies are required to assess whether it provides incremental risk information over current approaches.
Collapse
Affiliation(s)
- Zahra Raisi-Estabragh
- William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London, EC1M 6BQ, UK.
- Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK.
| | - Ahmed Salih
- Department of Computer Science, University of Verona, 37134, Verona, Italy
- Dept. de Matematiques I Informatica, University of Barcelona, 95P7+JH, Barcelona, Spain
| | - Polyxeni Gkontra
- Dept. de Matematiques I Informatica, University of Barcelona, 95P7+JH, Barcelona, Spain
| | - Angélica Atehortúa
- Dept. de Matematiques I Informatica, University of Barcelona, 95P7+JH, Barcelona, Spain
| | - Petia Radeva
- Dept. de Matematiques I Informatica, University of Barcelona, 95P7+JH, Barcelona, Spain
| | | | - Gloria Menegaz
- Department of Computer Science, University of Verona, 37134, Verona, Italy
| | - Nicholas C Harvey
- MRC Lifecourse Epidemiology Centre, University of Southampton, Southampton, UK
- NIHR Southampton Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Karim Lekadir
- Dept. de Matematiques I Informatica, University of Barcelona, 95P7+JH, Barcelona, Spain
| | - Steffen E Petersen
- William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London, EC1M 6BQ, UK
- Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, West Smithfield, London, EC1A 7BE, UK
- Health Data Research UK, London, UK
- Alan Turing Institute, London, UK
| |
Collapse
|
19
|
Battineni G, Hossain MA, Chintalapudi N, Amenta F. A Survey on the Role of Artificial Intelligence in Biobanking Studies: A Systematic Review. Diagnostics (Basel) 2022; 12:1179. [PMID: 35626333 PMCID: PMC9140088 DOI: 10.3390/diagnostics12051179] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2022] [Revised: 05/02/2022] [Accepted: 05/06/2022] [Indexed: 02/04/2023] Open
Abstract
Introduction: In biobanks, participants' biological samples are stored for future research. The application of artificial intelligence (AI) involves the analysis of data and the prediction of any pathological outcomes. In AI, models are used to diagnose diseases as well as classify and predict disease risks. Our research analyzed AI's role in the development of biobanks in the healthcare industry, systematically. Methods: The literature search was conducted using three digital reference databases, namely PubMed, CINAHL, and WoS. Guidelines for preferred reporting elements for systematic reviews and meta-analyses (PRISMA)-2020 in conducting the systematic review were followed. The search terms included "biobanks", "AI", "machine learning", and "deep learning", as well as combinations such as "biobanks with AI", "deep learning in the biobanking field", and "recent advances in biobanking". Only English-language papers were included in the study, and to assess the quality of selected works, the Newcastle-Ottawa scale (NOS) was used. The good quality range (NOS ≥ 7) is only considered for further review. Results: A literature analysis of the above entries resulted in 239 studies. Based on their relevance to the study's goal, research characteristics, and NOS criteria, we included 18 articles for reviewing. In the last decade, biobanks and artificial intelligence have had a relatively large impact on the medical system. Interestingly, UK biobanks account for the highest percentage of high-quality works, followed by Qatar, South Korea, Singapore, Japan, and Denmark. Conclusions: Translational bioinformatics probably represent a future leader in precision medicine. AI and machine learning applications to biobanking research may contribute to the development of biobanks for the utility of health services and citizens.
Collapse
Affiliation(s)
- Gopi Battineni
- Clinical Research Centre, School of Medicinal and Health Products Sciences, University of Camerino, 62032 Camerino, Italy; (M.A.H.); (N.C.); (F.A.)
| | | | | | | |
Collapse
|
20
|
Raisi-Estabragh Z, M'Charrak A, McCracken C, Biasiolli L, Ardissino M, Curtis EM, Aung N, Suemoto CK, Mackay C, Suri S, Nichols TE, Harvey NC, Petersen SE, Neubauer S. Associations of cognitive performance with cardiovascular magnetic resonance phenotypes in the UK Biobank. Eur Heart J Cardiovasc Imaging 2022; 23:663-672. [PMID: 33987659 PMCID: PMC9016359 DOI: 10.1093/ehjci/jeab075] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/05/2021] [Accepted: 04/07/2021] [Indexed: 01/22/2023] Open
Abstract
AIMS Existing evidence suggests links between brain and cardiovascular health. We investigated associations between cognitive performance and cardiovascular magnetic resonance (CMR) phenotypes in the UK Biobank, considering a range of potential confounders. METHODS AND RESULTS We studied 29 763 participants with CMR and cognitive testing, specifically, fluid intelligence (FI, 13 verbal-numeric reasoning questions), and reaction time (RT, a timed pairs matching exercise); both were considered continuous variables for modelling. We included the following CMR metrics: left and right ventricular (LV and RV) volumes in end-diastole and end-systole, LV/RV ejection fractions, LV/RV stroke volumes, LV mass, and aortic distensibility. Multivariable linear regression models were used to estimate the association of each CMR measure with FI and RT, adjusting for age, sex, smoking, education, deprivation, diabetes, hypertension, high cholesterol, prior myocardial infarction, alcohol intake, and exercise level. We report standardized beta-coefficients, 95% confidence intervals, and P-values adjusted for multiple testing. In this predominantly healthy cohort (average age 63.0 ± 7.5 years), better cognitive performance (higher FI, lower RT) was associated with larger LV/RV volumes, higher LV/RV stroke volumes, greater LV mass, and greater aortic distensibility in fully adjusted models. There was some evidence of non-linearity in the relationship between FI and LV end-systolic volume, with reversal of the direction of association at very high volumes. Associations were consistent for men and women and in different ages. CONCLUSION Better cognitive performance is associated with CMR measures likely representing a healthier cardiovascular phenotype. These relationships remained significant after adjustment for a range of cardiometabolic, lifestyle, and demographic factors, suggesting possible involvement of alternative disease mechanisms.
Collapse
Affiliation(s)
- Zahra Raisi-Estabragh
- Centre for Advanced Cardiovascular Imaging, William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London EC1M 6BQ, UK
- Barts Heart Centre, St Bartholomew’s Hospital, Barts Health NHS Trust, London EC1A 7BE, UK
| | - Amine M'Charrak
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, National Institute for Health Research Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, OX3 9DU, UK
| | - Celeste McCracken
- Centre for Advanced Cardiovascular Imaging, William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London EC1M 6BQ, UK
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, National Institute for Health Research Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, OX3 9DU, UK
| | - Luca Biasiolli
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, National Institute for Health Research Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, OX3 9DU, UK
| | | | - Elizabeth M Curtis
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, UK
| | - Nay Aung
- Centre for Advanced Cardiovascular Imaging, William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London EC1M 6BQ, UK
- Barts Heart Centre, St Bartholomew’s Hospital, Barts Health NHS Trust, London EC1A 7BE, UK
| | - Claudia K Suemoto
- Division of Geriatrics, Department of Internal Medicine, University of Sao Paulo Medical School, Sao Paulo, Brazil
| | - Clare Mackay
- Department of Psychiatry, University of Oxford, Oxford, UK
| | - Sana Suri
- Department of Psychiatry, University of Oxford, Oxford, UK
| | - Thomas E Nichols
- Nuffield Department of Population Health, Oxford Big Data Institute, Li Ka Shing Centre for Health Information and Discovery, University of Oxford, Oxford OX3 7LF, UK
- Nuffield Department of Clinical Neurosciences, Wellcome Centre for Integrative Neuroimaging, FMRIB, University of Oxford, Oxford OX3 9DU, UK
| | - Nicholas C Harvey
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, UK
- NIHR Southampton Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS Foundation Trust, Southampton, UK
| | - Steffen E Petersen
- Centre for Advanced Cardiovascular Imaging, William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London EC1M 6BQ, UK
- Barts Heart Centre, St Bartholomew’s Hospital, Barts Health NHS Trust, London EC1A 7BE, UK
| | - Stefan Neubauer
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, National Institute for Health Research Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, OX3 9DU, UK
| |
Collapse
|
21
|
From Accuracy to Reliability and Robustness in Cardiac Magnetic Resonance Image Segmentation: A Review. APPLIED SCIENCES-BASEL 2022. [DOI: 10.3390/app12083936] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/03/2023]
Abstract
Since the rise of deep learning (DL) in the mid-2010s, cardiac magnetic resonance (CMR) image segmentation has achieved state-of-the-art performance. Despite achieving inter-observer variability in terms of different accuracy performance measures, visual inspections reveal errors in most segmentation results, indicating a lack of reliability and robustness of DL segmentation models, which can be critical if a model was to be deployed into clinical practice. In this work, we aim to bring attention to reliability and robustness, two unmet needs of cardiac image segmentation methods, which are hampering their translation into practice. To this end, we first study the performance accuracy evolution of CMR segmentation, illustrate the improvements brought by DL algorithms and highlight the symptoms of performance stagnation. Afterwards, we provide formal definitions of reliability and robustness. Based on the two definitions, we identify the factors that limit the reliability and robustness of state-of-the-art deep learning CMR segmentation techniques. Finally, we give an overview of the current set of works that focus on improving the reliability and robustness of CMR segmentation, and we categorize them into two families of methods: quality control methods and model improvement techniques. The first category corresponds to simpler strategies that only aim to flag situations where a model may be incurring poor reliability or robustness. The second one, instead, directly tackles the problem by bringing improvements into different aspects of the CMR segmentation model development process. We aim to bring the attention of more researchers towards these emerging trends regarding the development of reliable and robust CMR segmentation frameworks, which can guarantee the safe use of DL in clinical routines and studies.
Collapse
|
22
|
Wang S, Chauhan D, Patel H, Amir-Khalili A, da Silva IF, Sojoudi A, Friedrich S, Singh A, Landeras L, Miller T, Ameyaw K, Narang A, Kawaji K, Tang Q, Mor-Avi V, Patel AR. Assessment of right ventricular size and function from cardiovascular magnetic resonance images using artificial intelligence. J Cardiovasc Magn Reson 2022; 24:27. [PMID: 35410226 PMCID: PMC8996592 DOI: 10.1186/s12968-022-00861-5] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2021] [Accepted: 03/29/2022] [Indexed: 11/12/2022] Open
Abstract
BACKGROUND Theoretically, artificial intelligence can provide an accurate automatic solution to measure right ventricular (RV) ejection fraction (RVEF) from cardiovascular magnetic resonance (CMR) images, despite the complex RV geometry. However, in our recent study, commercially available deep learning (DL) algorithms for RVEF quantification performed poorly in some patients. The current study was designed to test the hypothesis that quantification of RV function could be improved in these patients by using more diverse CMR datasets in addition to domain-specific quantitative performance evaluation metrics during the cross-validation phase of DL algorithm development. METHODS We identified 100 patients from our prior study who had the largest differences between manually measured and automated RVEF values. Automated RVEF measurements were performed using the original version of the algorithm (DL1), an updated version (DL2) developed from a dataset that included a wider range of RV pathology and validated using multiple domain-specific quantitative performance evaluation metrics, and conventional methodology performed by a core laboratory (CORE). Each of the DL-RVEF approaches was compared against CORE-RVEF reference values using linear regression and Bland-Altman analyses. Additionally, RVEF values were classified into 3 categories: ≤ 35%, 35-50%, and ≥ 50%. Agreement between RVEF classifications made by the DL approaches and the CORE measurements was tested. RESULTS CORE-RVEF and DL-RVEFs were obtained in all patients (feasibility of 100%). DL2-RVEF correlated with CORE-RVEF better than DL1-RVEF (r = 0.87 vs. r = 0.42), with narrower limits of agreement. As a result, DL2 algorithm also showed increasing accuracy from 0.53 to 0.80 for categorizing RV function. CONCLUSIONS The use of a new DL algorithm cross-validated on a dataset with a wide range of RV pathology using multiple domain-specific metrics resulted in a considerable improvement in the accuracy of automated RVEF measurements. This improvement was demonstrated in patients whose images were the most challenging and resulted in the largest RVEF errors. These findings underscore the critical importance of this strategy in the development of DL approaches for automated CMR measurements.
Collapse
Affiliation(s)
- Shuo Wang
- Department of Medicine, University of Chicago, University of Chicago Medical Center, 5758 S. Maryland Avenue, Chicago, IL, MC906760637, USA
- Peking University Shougang Hospital, Beijing, China
| | - Daksh Chauhan
- Department of Medicine, University of Chicago, University of Chicago Medical Center, 5758 S. Maryland Avenue, Chicago, IL, MC906760637, USA
| | - Hena Patel
- Department of Medicine, University of Chicago, University of Chicago Medical Center, 5758 S. Maryland Avenue, Chicago, IL, MC906760637, USA
| | | | | | | | | | - Amita Singh
- Department of Medicine, University of Chicago, University of Chicago Medical Center, 5758 S. Maryland Avenue, Chicago, IL, MC906760637, USA
| | - Luis Landeras
- Department of Radiology, University of Chicago, Chicago, IL, USA
| | - Tamari Miller
- Department of Medicine, University of Chicago, University of Chicago Medical Center, 5758 S. Maryland Avenue, Chicago, IL, MC906760637, USA
| | - Keith Ameyaw
- Department of Medicine, University of Chicago, University of Chicago Medical Center, 5758 S. Maryland Avenue, Chicago, IL, MC906760637, USA
| | | | - Keigo Kawaji
- Illinois Institute of Technology, Chicago, IL, USA
| | - Qiang Tang
- Peking University Shougang Hospital, Beijing, China
| | - Victor Mor-Avi
- Department of Medicine, University of Chicago, University of Chicago Medical Center, 5758 S. Maryland Avenue, Chicago, IL, MC906760637, USA
| | - Amit R Patel
- Department of Medicine, University of Chicago, University of Chicago Medical Center, 5758 S. Maryland Avenue, Chicago, IL, MC906760637, USA.
- Department of Radiology, University of Chicago, Chicago, IL, USA.
| |
Collapse
|
23
|
Rauseo E, Omer M, Amir-Khalili A, Sojoudi A, Le TT, Cook SA, Hausenloy DJ, Ang B, Toh DF, Bryant J, Chin CWL, Paiva JM, Fung K, Cooper J, Khanji MY, Aung N, Petersen SE. A Systematic Quality Scoring Analysis to Assess Automated Cardiovascular Magnetic Resonance Segmentation Algorithms. Front Cardiovasc Med 2022; 8:816985. [PMID: 35242820 PMCID: PMC8886212 DOI: 10.3389/fcvm.2021.816985] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/17/2021] [Accepted: 12/22/2021] [Indexed: 12/29/2022] Open
Abstract
Background The quantitative measures used to assess the performance of automated methods often do not reflect the clinical acceptability of contouring. A quality-based assessment of automated cardiac magnetic resonance (CMR) segmentation more relevant to clinical practice is therefore needed. Objective We propose a new method for assessing the quality of machine learning (ML) outputs. We evaluate the clinical utility of the proposed method as it is employed to systematically analyse the quality of an automated contouring algorithm. Methods A dataset of short-axis (SAX) cine CMR images from a clinically heterogeneous population (n = 217) were manually contoured by a team of experienced investigators. On the same images we derived automated contours using a ML algorithm. A contour quality scoring application randomly presented manual and automated contours to four blinded clinicians, who were asked to assign a quality score from a predefined rubric. Firstly, we analyzed the distribution of quality scores between the two contouring methods across all clinicians. Secondly, we analyzed the interobserver reliability between the raters. Finally, we examined whether there was a variation in scores based on the type of contour, SAX slice level, and underlying disease. Results The overall distribution of scores between the two methods was significantly different, with automated contours scoring better than the manual (OR (95% CI) = 1.17 (1.07–1.28), p = 0.001; n = 9401). There was substantial scoring agreement between raters for each contouring method independently, albeit it was significantly better for automated segmentation (automated: AC2 = 0.940, 95% CI, 0.937–0.943 vs manual: AC2 = 0.934, 95% CI, 0.931–0.937; p = 0.006). Next, the analysis of quality scores based on different factors was performed. Our approach helped identify trends patterns of lower segmentation quality as observed for left ventricle epicardial and basal contours with both methods. Similarly, significant differences in quality between the two methods were also found in dilated cardiomyopathy and hypertension. Conclusions Our results confirm the ability of our systematic scoring analysis to determine the clinical acceptability of automated contours. This approach focused on the contours' clinical utility could ultimately improve clinicians' confidence in artificial intelligence and its acceptability in the clinical workflow.
Collapse
Affiliation(s)
- Elisa Rauseo
- NIHR Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University, London, United Kingdom.,Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom
| | | | | | | | - Thu-Thao Le
- National Heart Centre Singapore, Singapore, Singapore
| | - Stuart Alexander Cook
- National Heart Centre Singapore, Singapore, Singapore.,Cardiovascular and Metabolic Disorders Program, Duke-National University of Singapore, Singapore, Singapore
| | - Derek John Hausenloy
- National Heart Centre Singapore, Singapore, Singapore.,Cardiovascular and Metabolic Disorders Program, Duke-National University of Singapore, Singapore, Singapore.,Yong Loo Lin School of Medicine, National University Singapore, Singapore, Singapore.,The Hatter Cardiovascular Institute, University College London, London, United Kingdom.,Cardiovascular Research Center, College of Medical and Health Sciences, Asia University, Taichung, Taiwan
| | - Briana Ang
- National Heart Centre Singapore, Singapore, Singapore
| | | | | | | | | | - Kenneth Fung
- NIHR Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University, London, United Kingdom.,Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom
| | - Jackie Cooper
- NIHR Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University, London, United Kingdom
| | - Mohammed Yunus Khanji
- NIHR Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University, London, United Kingdom.,Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.,Department of Cardiology, Newham University Hospital, Barts Health NHS Trust, London, United Kingdom
| | - Nay Aung
- NIHR Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University, London, United Kingdom.,Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom
| | - Steffen Erhard Petersen
- NIHR Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University, London, United Kingdom.,Barts Heart Centre, St Bartholomew's Hospital, Barts Health NHS Trust, London, United Kingdom.,Health Data Research UK, London, United Kingdom.,Alan Turing Institute, London, United Kingdom
| |
Collapse
|
24
|
Diaz-Pinto A, Ravikumar N, Attar R, Suinesiaputra A, Zhao Y, Levelt E, Dall’Armellina E, Lorenzi M, Chen Q, Keenan TDL, Agrón E, Chew EY, Lu Z, Gale CP, Gale RP, Plein S, Frangi AF. Predicting myocardial infarction through retinal scans and minimal personal information. NAT MACH INTELL 2022. [DOI: 10.1038/s42256-021-00427-7] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
|
25
|
Raisi-Estabragh Z, Jaggi A, Gkontra P, McCracken C, Aung N, Munroe PB, Neubauer S, Harvey NC, Lekadir K, Petersen SE. Cardiac Magnetic Resonance Radiomics Reveal Differential Impact of Sex, Age, and Vascular Risk Factors on Cardiac Structure and Myocardial Tissue. Front Cardiovasc Med 2021; 8:763361. [PMID: 35004880 PMCID: PMC8727756 DOI: 10.3389/fcvm.2021.763361] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/23/2021] [Accepted: 11/30/2021] [Indexed: 11/30/2022] Open
Abstract
Background: Cardiovascular magnetic resonance (CMR) radiomics analysis provides multiple quantifiers of ventricular shape and myocardial texture, which may be used for detailed cardiovascular phenotyping. Objectives: We studied variation in CMR radiomics phenotypes by age and sex in healthy UK Biobank participants. Then, we examined independent associations of classical vascular risk factors (VRFs: smoking, diabetes, hypertension, high cholesterol) with CMR radiomics features, considering potential sex and age differential relationships. Design: Image acquisition was with 1.5 Tesla scanners (MAGNETOM Aera, Siemens). Three regions of interest were segmented from short axis stack images using an automated pipeline: right ventricle, left ventricle, myocardium. We extracted 237 radiomics features from each study using Pyradiomics. In a healthy subset of participants (n = 14,902) without cardiovascular disease or VRFs, we estimated independent associations of age and sex with each radiomics feature using linear regression models adjusted for body size. We then created a sample comprising individuals with at least one VRF matched to an equal number of healthy participants (n = 27,400). We linearly modelled each radiomics feature against age, sex, body size, and all the VRFs. Bonferroni adjustment for multiple testing was applied to all p-values. To aid interpretation, we organised the results into six feature clusters. Results: Amongst the healthy subset, men had larger ventricles with dimmer and less texturally complex myocardium than women. Increasing age was associated with smaller ventricles and greater variation in myocardial intensities. Broadly, all the VRFs were associated with dimmer, less varied signal intensities, greater uniformity of local intensity levels, and greater relative presence of low signal intensity areas within the myocardium. Diabetes and high cholesterol were also associated with smaller ventricular size, this association was of greater magnitude in men than women. The pattern of alteration of radiomics features with the VRFs was broadly consistent in men and women. However, the associations between intensity based radiomics features with both diabetes and hypertension were more prominent in women than men. Conclusions: We demonstrate novel independent associations of sex, age, and major VRFs with CMR radiomics phenotypes. Further studies into the nature and clinical significance of these phenotypes are needed.
Collapse
Affiliation(s)
- Zahra Raisi-Estabragh
- National Institute for Health Research (NIHR) Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
- Barts Health National Health Service (NHS) Trust, Barts Heart Centre, St Bartholomew's Hospital, West Smithfield, United Kingdom
| | - Akshay Jaggi
- Departament de Matemàtiques and Informàtica, Universitat de Barcelona, Barcelona, Spain
| | - Polyxeni Gkontra
- Departament de Matemàtiques and Informàtica, Universitat de Barcelona, Barcelona, Spain
| | - Celeste McCracken
- National Institute for Health Research (NIHR) Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, National Institute for Health Research Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom
| | - Nay Aung
- National Institute for Health Research (NIHR) Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
- Barts Health National Health Service (NHS) Trust, Barts Heart Centre, St Bartholomew's Hospital, West Smithfield, United Kingdom
| | - Patricia B. Munroe
- National Institute for Health Research (NIHR) Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
| | - Stefan Neubauer
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, National Institute for Health Research Oxford Biomedical Research Centre, Oxford University Hospitals NHS Foundation Trust, Oxford, United Kingdom
| | - Nicholas C. Harvey
- Medical Research Council (MRC) Lifecourse Epidemiology Centre, University of Southampton, Southampton, United Kingdom
- NIHR Southampton Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS Foundation Trust, Southampton, United Kingdom
| | - Karim Lekadir
- Departament de Matemàtiques and Informàtica, Universitat de Barcelona, Barcelona, Spain
| | - Steffen E. Petersen
- National Institute for Health Research (NIHR) Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University of London, London, United Kingdom
- Barts Health National Health Service (NHS) Trust, Barts Heart Centre, St Bartholomew's Hospital, West Smithfield, United Kingdom
- Health Data Research UK, London, United Kingdom
- Alan Turing Institute, London, United Kingdom
| |
Collapse
|
26
|
Brain age estimation at tract group level and its association with daily life measures, cardiac risk factors and genetic variants. Sci Rep 2021; 11:20563. [PMID: 34663856 PMCID: PMC8523533 DOI: 10.1038/s41598-021-99153-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2021] [Accepted: 09/14/2021] [Indexed: 11/08/2022] Open
Abstract
Brain age can be estimated using different Magnetic Resonance Imaging (MRI) modalities including diffusion MRI. Recent studies demonstrated that white matter (WM) tracts that share the same function might experience similar alterations. Therefore, in this work, we sought to investigate such issue focusing on five WM bundles holding that feature that is Association, Brainstem, Commissural, Limbic and Projection fibers, respectively. For each tract group, we estimated brain age for 15,335 healthy participants from United Kingdom Biobank relying on diffusion MRI data derived endophenotypes, Bayesian ridge regression modeling and 10 fold-cross validation. Furthermore, we estimated brain age for an Ensemble model that gathers all the considered WM bundles. Association analysis was subsequently performed between the estimated brain age delta as resulting from the six models, that is for each tract group as well as for the Ensemble model, and 38 daily life style measures, 14 cardiac risk factors and cardiovascular magnetic resonance imaging features and genetic variants. The Ensemble model that used all tracts from all fiber groups (FG) performed better than other models to estimate brain age. Limbic tracts based model reached the highest accuracy with a Mean Absolute Error (MAE) of 5.08, followed by the Commissural ([Formula: see text]), Association ([Formula: see text]), and Projection ([Formula: see text]) ones. The Brainstem tracts based model was the less accurate achieving a MAE of 5.86. Accordingly, our study suggests that the Limbic tracts experience less brain aging or allows for more accurate estimates compared to other tract groups. Moreover, the results suggest that Limbic tract leads to the largest number of significant associations with daily lifestyle factors than the other tract groups. Lastly, two SNPs were significantly (p value [Formula: see text]) associated with brain age delta in the Projection fibers. Those SNPs are mapped to HIST1H1A and SLC17A3 genes.
Collapse
|
27
|
Zakeri A, Hokmabadi A, Ravikumar N, Frangi AF, Gooya A. A probabilistic deep motion model for unsupervised cardiac shape anomaly assessment. Med Image Anal 2021; 75:102276. [PMID: 34753021 DOI: 10.1016/j.media.2021.102276] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 10/10/2021] [Accepted: 10/15/2021] [Indexed: 11/16/2022]
Abstract
Automatic shape anomaly detection in large-scale imaging data can be useful for screening suboptimal segmentations and pathologies altering the cardiac morphology without intensive manual labour. We propose a deep probabilistic model for local anomaly detection in sequences of heart shapes, modelled as point sets, in a cardiac cycle. A deep recurrent encoder-decoder network captures the spatio-temporal dependencies to predict the next shape in the cycle and thus derive the outlier points that are attributed to excessive deviations from the network prediction. A predictive mixture distribution models the inlier and outlier classes via Gaussian and uniform distributions, respectively. A Gibbs sampling Expectation-Maximisation (EM) algorithm computes soft anomaly scores of the points via the posterior probabilities of each class in the E-step and estimates the parameters of the network and the predictive distribution in the M-step. We demonstrate the versatility of the method using two shape datasets derived from: (i) one million biventricular CMR images from 20,000 participants in the UK Biobank (UKB), and (ii) routine diagnostic imaging from Multi-Centre, Multi-Vendor, and Multi-Disease Cardiac Image (M&Ms). Experiments show that the detected shape anomalies in the UKB dataset are mostly associated with poor segmentation quality, and the predicted shape sequences show significant improvement over the input sequences. Furthermore, evaluations on U-Net based shapes from the M&Ms dataset reveals that the anomalies are attributable to the underlying pathologies that affect the ventricles. The proposed model can therefore be used as an effective mechanism to sift shape anomalies in large-scale cardiac imaging pipelines for further analysis.
Collapse
Affiliation(s)
- Arezoo Zakeri
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK.
| | - Alireza Hokmabadi
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK
| | - Nishant Ravikumar
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK
| | - Alejandro F Frangi
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK
| | - Ali Gooya
- Centre for Computational Imaging and Simulation Technologies in Biomedicine (CISTIB), School of Computing, University of Leeds, Leeds, UK.
| |
Collapse
|
28
|
Rauseo E, Izquierdo Morcillo C, Raisi-Estabragh Z, Gkontra P, Aung N, Lekadir K, Petersen SE. New Imaging Signatures of Cardiac Alterations in Ischaemic Heart Disease and Cerebrovascular Disease Using CMR Radiomics. Front Cardiovasc Med 2021; 8:716577. [PMID: 34631820 PMCID: PMC8494975 DOI: 10.3389/fcvm.2021.716577] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Accepted: 09/02/2021] [Indexed: 11/17/2022] Open
Abstract
Background: Ischaemic heart disease (IHD) and cerebrovascular disease are two closely inter-related clinical entities. Cardiovascular magnetic resonance (CMR) radiomics may capture subtle cardiac changes associated with these two diseases providing new insights into the brain-heart interactions. Objective: To define the CMR radiomics signatures for IHD and cerebrovascular disease and study their incremental value for disease discrimination over conventional CMR indices. Methods: We analysed CMR images of UK Biobank's subjects with pre-existing IHD, ischaemic cerebrovascular disease, myocardial infarction (MI), and ischaemic stroke (IS) (n = 779, 267, 525, and 107, respectively). Each disease group was compared with an equal number of healthy controls. We extracted 446 shape, first-order, and texture radiomics features from three regions of interest (right ventricle, left ventricle, and left ventricular myocardium) in end-diastole and end-systole defined from segmentation of short-axis cine images. Systematic feature selection combined with machine learning (ML) algorithms (support vector machine and random forest) and 10-fold cross-validation tests were used to build the radiomics signature for each condition. We compared the discriminatory power achieved by the radiomics signature with conventional indices for each disease group, using the area under the curve (AUC), receiver operating characteristic (ROC) analysis, and paired t-test for statistical significance. A third model combining both radiomics and conventional indices was also evaluated. Results: In all the study groups, radiomics signatures provided a significantly better disease discrimination than conventional indices, as suggested by AUC (IHD:0.82 vs. 0.75; cerebrovascular disease: 0.79 vs. 0.77; MI: 0.87 vs. 0.79, and IS: 0.81 vs. 0.72). Similar results were observed with the combined models. In IHD and MI, LV shape radiomics were dominant. However, in IS and cerebrovascular disease, the combination of shape and intensity-based features improved the disease discrimination. A notable overlap of the radiomics signatures of IHD and cerebrovascular disease was also found. Conclusions: This study demonstrates the potential value of CMR radiomics over conventional indices in detecting subtle cardiac changes associated with chronic ischaemic processes involving the brain and heart, even in the presence of more heterogeneous clinical pictures. Radiomics analysis might also improve our understanding of the complex mechanisms behind the brain-heart interactions during ischaemia.
Collapse
Affiliation(s)
- Elisa Rauseo
- William Harvey Research Institute, National Institute for Health Research Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London, United Kingdom
- Barts Heart Centre, St Bartholomew's Hospital, Barts Health National Health Service Trust, London, United Kingdom
| | - Cristian Izquierdo Morcillo
- Departament de Matematiques i Informatica, Universitat de Barcelona, Artificial Intelligence in Medicine Lab, Barcelona, Spain
| | - Zahra Raisi-Estabragh
- William Harvey Research Institute, National Institute for Health Research Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London, United Kingdom
- Barts Heart Centre, St Bartholomew's Hospital, Barts Health National Health Service Trust, London, United Kingdom
| | - Polyxeni Gkontra
- Departament de Matematiques i Informatica, Universitat de Barcelona, Artificial Intelligence in Medicine Lab, Barcelona, Spain
| | - Nay Aung
- William Harvey Research Institute, National Institute for Health Research Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London, United Kingdom
- Barts Heart Centre, St Bartholomew's Hospital, Barts Health National Health Service Trust, London, United Kingdom
| | - Karim Lekadir
- Departament de Matematiques i Informatica, Universitat de Barcelona, Artificial Intelligence in Medicine Lab, Barcelona, Spain
| | - Steffen E. Petersen
- William Harvey Research Institute, National Institute for Health Research Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London, United Kingdom
- Barts Heart Centre, St Bartholomew's Hospital, Barts Health National Health Service Trust, London, United Kingdom
- Health Data Research UK, London, United Kingdom
- Alan Turing Institute, London, United Kingdom
| |
Collapse
|
29
|
Miller R, Kerfoot E, Mauger C, Ismail TF, Young AA, Nordsletten DA. An Implementation of Patient-Specific Biventricular Mechanics Simulations With a Deep Learning and Computational Pipeline. Front Physiol 2021; 12:716597. [PMID: 34603077 PMCID: PMC8481785 DOI: 10.3389/fphys.2021.716597] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/28/2021] [Accepted: 08/06/2021] [Indexed: 02/04/2023] Open
Abstract
Parameterised patient-specific models of the heart enable quantitative analysis of cardiac function as well as estimation of regional stress and intrinsic tissue stiffness. However, the development of personalised models and subsequent simulations have often required lengthy manual setup, from image labelling through to generating the finite element model and assigning boundary conditions. Recently, rapid patient-specific finite element modelling has been made possible through the use of machine learning techniques. In this paper, utilising multiple neural networks for image labelling and detection of valve landmarks, together with streamlined data integration, a pipeline for generating patient-specific biventricular models is applied to clinically-acquired data from a diverse cohort of individuals, including hypertrophic and dilated cardiomyopathy patients and healthy volunteers. Valve motion from tracked landmarks as well as cavity volumes measured from labelled images are used to drive realistic motion and estimate passive tissue stiffness values. The neural networks are shown to accurately label cardiac regions and features for these diverse morphologies. Furthermore, differences in global intrinsic parameters, such as tissue anisotropy and normalised active tension, between groups illustrate respective underlying changes in tissue composition and/or structure as a result of pathology. This study shows the successful application of a generic pipeline for biventricular modelling, incorporating artificial intelligence solutions, within a diverse cohort.
Collapse
Affiliation(s)
- Renee Miller
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Eric Kerfoot
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Charlène Mauger
- Auckland MR Research Group, University of Auckland, Auckland, New Zealand
| | - Tevfik F. Ismail
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Alistair A. Young
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Auckland MR Research Group, University of Auckland, Auckland, New Zealand
| | - David A. Nordsletten
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Department of Biomedical Engineering and Cardiac Surgery, University of Michigan, Ann Arbor, MI, United States
| |
Collapse
|
30
|
Sermesant M, Delingette H, Cochet H, Jaïs P, Ayache N. Applications of artificial intelligence in cardiovascular imaging. Nat Rev Cardiol 2021; 18:600-609. [PMID: 33712806 DOI: 10.1038/s41569-021-00527-2] [Citation(s) in RCA: 73] [Impact Index Per Article: 18.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 02/08/2021] [Indexed: 01/31/2023]
Abstract
Research into artificial intelligence (AI) has made tremendous progress over the past decade. In particular, the AI-powered analysis of images and signals has reached human-level performance in many applications owing to the efficiency of modern machine learning methods, in particular deep learning using convolutional neural networks. Research into the application of AI to medical imaging is now very active, especially in the field of cardiovascular imaging because of the challenges associated with acquiring and analysing images of this dynamic organ. In this Review, we discuss the clinical questions in cardiovascular imaging that AI can be used to address and the principal methodological AI approaches that have been developed to solve the related image analysis problems. Some approaches are purely data-driven and rely mainly on statistical associations, whereas others integrate anatomical and physiological information through additional statistical, geometric and biophysical models of the human heart. In a structured manner, we provide representative examples of each of these approaches, with particular attention to the underlying computational imaging challenges. Finally, we discuss the remaining limitations of AI approaches in cardiovascular imaging (such as generalizability and explainability) and how they can be overcome.
Collapse
Affiliation(s)
| | | | - Hubert Cochet
- IHU Liryc, CHU Bordeaux, Université Bordeaux, Inserm 1045, Pessac, France
| | - Pierre Jaïs
- IHU Liryc, CHU Bordeaux, Université Bordeaux, Inserm 1045, Pessac, France
| | | |
Collapse
|
31
|
Vesal S, Gu M, Maier A, Ravikumar N. Spatio-Temporal Multi-Task Learning for Cardiac MRI Left Ventricle Quantification. IEEE J Biomed Health Inform 2021; 25:2698-2709. [PMID: 33351771 DOI: 10.1109/jbhi.2020.3046449] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Quantitative assessment of cardiac left ventricle (LV) morphology is essential to assess cardiac function and improve the diagnosis of different cardiovascular diseases. In current clinical practice, LV quantification depends on the measurement of myocardial shape indices, which is usually achieved by manual contouring of the endo- and epicardial. However, this process subjected to inter and intra-observer variability, and it is a time-consuming and tedious task. In this article, we propose a spatio-temporal multi-task learning approach to obtain a complete set of measurements quantifying cardiac LV morphology, regional-wall thickness (RWT), and additionally detecting the cardiac phase cycle (systole and diastole) for a given 3D Cine-magnetic resonance (MR) image sequence. We first segment cardiac LVs using an encoder-decoder network and then introduce a multitask framework to regress 11 LV indices and classify the cardiac phase, as parallel tasks during model optimization. The proposed deep learning model is based on the 3D spatio-temporal convolutions, which extract spatial and temporal features from MR images. We demonstrate the efficacy of the proposed method using cine-MR sequences of 145 subjects and comparing the performance with other state-of-the-art quantification methods. The proposed method obtained high prediction accuracy, with an average mean absolute error (MAE) of 129 mm 2, 1.23 mm, 1.76 mm, Pearson correlation coefficient (PCC) of 96.4%, 87.2%, and 97.5% for LV and myocardium (Myo) cavity regions, 6 RWTs, 3 LV dimensions, and an error rate of 9.0% for phase classification. The experimental results highlight the robustness of the proposed method, despite varying degrees of cardiac morphology, image appearance, and low contrast in the cardiac MR sequences.
Collapse
|
32
|
Raisi-Estabragh Z, McCracken C, Gkontra P, Jaggi A, Ardissino M, Cooper J, Biasiolli L, Aung N, Piechnik SK, Neubauer S, Munroe PB, Lekadir K, Harvey NC, Petersen SE. Associations of Meat and Fish Consumption With Conventional and Radiomics Cardiovascular Magnetic Resonance Phenotypes in the UK Biobank. Front Cardiovasc Med 2021; 8:667849. [PMID: 34026874 PMCID: PMC8133433 DOI: 10.3389/fcvm.2021.667849] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2021] [Accepted: 04/07/2021] [Indexed: 01/04/2023] Open
Abstract
Background: Greater red and processed meat consumption has been linked to adverse cardiovascular outcomes. However, the impact of these exposures on cardiovascular magnetic resonance (CMR) phenotypes has not been adequately studied. Objective: We describe novel associations of meat intake with cardiovascular phenotypes and investigate underlying mechanisms through consideration of a range of covariates. Design: We studied 19,408 UK Biobank participants with CMR data available. Average daily red and processed meat consumption was determined through food frequency questionnaires and expressed as a continuous variable. Oily fish was studied as a comparator, previously associated with favourable cardiac outcomes. We considered associations with conventional CMR indices (ventricular volumes, ejection fraction, stroke volume, left ventricular mass), novel CMR radiomics features (shape, first-order, texture), and arterial compliance measures (arterial stiffness index, aortic distensibility). We used multivariable linear regression to investigate relationships between meat intake and cardiovascular phenotypes, adjusting for confounders (age, sex, deprivation, educational level, smoking, alcohol intake, exercise) and potential covariates on the causal pathway (hypertension, hypercholesterolaemia, diabetes, body mass index). Results: Greater red and processed meat consumption was associated with an unhealthy pattern of biventricular remodelling, worse cardiac function, and poorer arterial compliance. In contrast, greater oily fish consumption was associated with a healthier cardiovascular phenotype and better arterial compliance. There was partial attenuation of associations between red meat and conventional CMR indices with addition of covariates potentially on the causal pathway, indicating a possible mechanistic role for these cardiometabolic morbidities. However, other associations were not altered with inclusion of these covariates, suggesting importance of alternative biological mechanisms underlying these relationships. Radiomics analysis provided deeper phenotyping, demonstrating association of the different dietary habits with distinct ventricular geometry and left ventricular myocardial texture patterns. Conclusions: Greater red and processed meat consumption is associated with impaired cardiovascular health, both in terms of markers of arterial disease and of cardiac structure and function. Cardiometabolic morbidities appeared to have a mechanistic role in the associations of red meat with ventricular phenotypes, but less so for other associations suggesting importance of alternative mechanism for these relationships.
Collapse
Affiliation(s)
- Zahra Raisi-Estabragh
- National Institute for Health Research (NIHR) Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University of London, Charterhouse Square, London, United Kingdom.,Barts Heart Centre, St Bartholomew's Hospital, Barts Health National Health Service (NHS) Trust, London, United Kingdom
| | - Celeste McCracken
- National Institute for Health Research (NIHR) Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University of London, Charterhouse Square, London, United Kingdom
| | - Polyxeni Gkontra
- Departament de Matemàtiques and Informàtica, Universitat de Barcelona, Barcelona, Spain
| | - Akshay Jaggi
- Departament de Matemàtiques and Informàtica, Universitat de Barcelona, Barcelona, Spain
| | - Maddalena Ardissino
- Imperial College London, Sir Alexander Fleming Building, London, United Kingdom
| | - Jackie Cooper
- National Institute for Health Research (NIHR) Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University of London, Charterhouse Square, London, United Kingdom
| | - Luca Biasiolli
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, National Institute for Health Research Oxford Biomedical Research Centre, Oxford University Hospitals National Health Service Foundation Trust, University of Oxford, Oxford, United Kingdom
| | - Nay Aung
- National Institute for Health Research (NIHR) Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University of London, Charterhouse Square, London, United Kingdom.,Barts Heart Centre, St Bartholomew's Hospital, Barts Health National Health Service (NHS) Trust, London, United Kingdom
| | - Stefan K Piechnik
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, National Institute for Health Research Oxford Biomedical Research Centre, Oxford University Hospitals National Health Service Foundation Trust, University of Oxford, Oxford, United Kingdom
| | - Stefan Neubauer
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, National Institute for Health Research Oxford Biomedical Research Centre, Oxford University Hospitals National Health Service Foundation Trust, University of Oxford, Oxford, United Kingdom
| | - Patricia B Munroe
- National Institute for Health Research (NIHR) Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University of London, Charterhouse Square, London, United Kingdom
| | - Karim Lekadir
- Departament de Matemàtiques and Informàtica, Universitat de Barcelona, Barcelona, Spain
| | - Nicholas C Harvey
- Medical Research Council (MRC) Lifecourse Epidemiology Unit, University of Southampton, Southampton, United Kingdom.,National Institute for Health Research (NIHR) Southampton Biomedical Research Centre, University of Southampton and University Hospital Southampton National Health Service (NHS) Foundation Trust, Southampton, United Kingdom
| | - Steffen E Petersen
- National Institute for Health Research (NIHR) Barts Biomedical Research Centre, William Harvey Research Institute, Queen Mary University of London, Charterhouse Square, London, United Kingdom.,Barts Heart Centre, St Bartholomew's Hospital, Barts Health National Health Service (NHS) Trust, London, United Kingdom
| |
Collapse
|
33
|
Raisi-Estabragh Z, Harvey NC, Neubauer S, Petersen SE. Cardiovascular magnetic resonance imaging in the UK Biobank: a major international health research resource. Eur Heart J Cardiovasc Imaging 2021; 22:251-258. [PMID: 33164079 PMCID: PMC7899275 DOI: 10.1093/ehjci/jeaa297] [Citation(s) in RCA: 41] [Impact Index Per Article: 10.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Accepted: 10/12/2020] [Indexed: 12/12/2022] Open
Abstract
The UK Biobank (UKB) is a health research resource of major international importance, incorporating comprehensive characterization of >500 000 men and women recruited between 2006 and 2010 from across the UK. There is prospective tracking of health outcomes for all participants through linkages with national cohorts (death registers, cancer registers, electronic hospital records, and primary care records). The dataset has been enhanced with the UKB imaging study, which aims to scan a subset of 100 000 participants. The imaging protocol includes magnetic resonance imaging of the brain, heart, and abdomen, carotid ultrasound, and whole-body dual X-ray absorptiometry. Since its launch in 2015, over 48 000 participants have completed the imaging study with scheduled completion in 2023. Repeat imaging of 10 000 participants has been approved and commenced in 2019. The cardiovascular magnetic resonance (CMR) scan provides detailed assessment of cardiac structure and function comprising bright blood anatomic assessment (sagittal, coronal, and axial), left and right ventricular cine images (long and short axes), myocardial tagging, native T1 mapping, aortic flow, and imaging of the thoracic aorta. The UKB is an open access resource available to health researchers across all scientific disciplines from both academia and industry with no preferential access or exclusivity. In this paper, we consider how we may best utilize the UKB CMR data to advance cardiovascular research and review notable achievements to date.
Collapse
Affiliation(s)
- Zahra Raisi-Estabragh
- William Harvey Research Institute, Centre for Advanced Cardiovascular Imaging, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London EC1M 6BQ, UK
- Barts Heart Centre, Department of Cardiac Imaging, St. Bartholomew's Hospital, Barts Health NHS Trust, London EC1A 7BE, UK
| | - Nicholas C Harvey
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, SO16 6YD, UK
- NIHR Southampton Biomedical Research Centre, University of Southampton and University Hospital Southampton NHS Foundation Trust, Southampton, SO16 6YD, UK
| | - Stefan Neubauer
- Division of Cardiovascular Medicine, Radcliffe Department of Medicine, National Institute for Health Research Oxford Biomedical Research Centre, University of Oxford, Oxford, OX3 9DU, UK
| | - Steffen E Petersen
- William Harvey Research Institute, Centre for Advanced Cardiovascular Imaging, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London EC1M 6BQ, UK
- Barts Heart Centre, Department of Cardiac Imaging, St. Bartholomew's Hospital, Barts Health NHS Trust, London EC1A 7BE, UK
| |
Collapse
|
34
|
Langner T, Östling A, Maldonis L, Karlsson A, Olmo D, Lindgren D, Wallin A, Lundin L, Strand R, Ahlström H, Kullberg J. Kidney segmentation in neck-to-knee body MRI of 40,000 UK Biobank participants. Sci Rep 2020; 10:20963. [PMID: 33262432 PMCID: PMC7708493 DOI: 10.1038/s41598-020-77981-4] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/18/2020] [Accepted: 11/17/2020] [Indexed: 02/06/2023] Open
Abstract
The UK Biobank is collecting extensive data on health-related characteristics of over half a million volunteers. The biological samples of blood and urine can provide valuable insight on kidney function, with important links to cardiovascular and metabolic health. Further information on kidney anatomy could be obtained by medical imaging. In contrast to the brain, heart, liver, and pancreas, no dedicated Magnetic Resonance Imaging (MRI) is planned for the kidneys. An image-based assessment is nonetheless feasible in the neck-to-knee body MRI intended for abdominal body composition analysis, which also covers the kidneys. In this work, a pipeline for automated segmentation of parenchymal kidney volume in UK Biobank neck-to-knee body MRI is proposed. The underlying neural network reaches a relative error of 3.8%, with Dice score 0.956 in validation on 64 subjects, close to the 2.6% and Dice score 0.962 for repeated segmentation by one human operator. The released MRI of about 40,000 subjects can be processed within one day, yielding volume measurements of left and right kidney. Algorithmic quality ratings enabled the exclusion of outliers and potential failure cases. The resulting measurements can be studied and shared for large-scale investigation of associations and longitudinal changes in parenchymal kidney volume.
Collapse
Affiliation(s)
- Taro Langner
- Department of Surgical Sciences, Uppsala University, 751 85, Uppsala, Sweden.
| | - Andreas Östling
- Department of Surgical Sciences, Uppsala University, 751 85, Uppsala, Sweden
| | - Lukas Maldonis
- Antaros Medical AB, BioVenture Hub, 431 53, Mölndal, Sweden
| | - Albin Karlsson
- Department of Surgical Sciences, Uppsala University, 751 85, Uppsala, Sweden
| | - Daniel Olmo
- Department of Surgical Sciences, Uppsala University, 751 85, Uppsala, Sweden
| | - Dag Lindgren
- Antaros Medical AB, BioVenture Hub, 431 53, Mölndal, Sweden
| | - Andreas Wallin
- Antaros Medical AB, BioVenture Hub, 431 53, Mölndal, Sweden
| | - Lowe Lundin
- Antaros Medical AB, BioVenture Hub, 431 53, Mölndal, Sweden
| | - Robin Strand
- Department of Surgical Sciences, Uppsala University, 751 85, Uppsala, Sweden
- Department of Information Technology, Uppsala University, 751 85, Uppsala, Sweden
| | - Håkan Ahlström
- Department of Surgical Sciences, Uppsala University, 751 85, Uppsala, Sweden
- Antaros Medical AB, BioVenture Hub, 431 53, Mölndal, Sweden
| | - Joel Kullberg
- Department of Surgical Sciences, Uppsala University, 751 85, Uppsala, Sweden
- Antaros Medical AB, BioVenture Hub, 431 53, Mölndal, Sweden
| |
Collapse
|
35
|
Recovering from missing data in population imaging - Cardiac MR image imputation via conditional generative adversarial nets. Med Image Anal 2020; 67:101812. [PMID: 33129140 DOI: 10.1016/j.media.2020.101812] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2020] [Revised: 07/05/2020] [Accepted: 08/19/2020] [Indexed: 11/21/2022]
Abstract
Accurate ventricular volume measurements are the primary indicators of normal/abnor- mal cardiac function and are dependent on the Cardiac Magnetic Resonance (CMR) volumes being complete. However, missing or unusable slices owing to the presence of image artefacts such as respiratory or motion ghosting, aliasing, ringing and signal loss in CMR sequences, significantly hinder accuracy of anatomical and functional cardiac quantification, and recovering from those is insufficiently addressed in population imaging. In this work, we propose a new robust approach, coined Image Imputation Generative Adversarial Network (I2-GAN), to learn key features of cardiac short axis (SAX) slices near missing information, and use them as conditional variables to infer missing slices in the query volumes. In I2-GAN, the slices are first mapped to latent vectors with position features through a regression net. The latent vector corresponding to the desired position is then projected onto the slice manifold, conditioned on intensity features through a generator net. The generator comprises residual blocks with normalisation layers that are modulated with auxiliary slice information, enabling propagation of fine details through the network. In addition, a multi-scale discriminator was implemented, along with a discriminator-based feature matching loss, to further enhance performance and encourage the synthesis of visually realistic slices. Experimental results show that our method achieves significant improvements over the state-of-the-art, in missing slice imputation for CMR, with an average SSIM of 0.872. Linear regression analysis yields good agreement between reference and imputed CMR images for all cardiac measurements, with correlation coefficients of 0.991 for left ventricular volume, 0.977 for left ventricular mass and 0.961 for right ventricular volume.
Collapse
|
36
|
Hu H, Pan N, Yin T, Liu H, Du B. Hybrid method for automatic construction of 3D-ASM image intensity models for left ventricle. Neurocomputing 2020. [DOI: 10.1016/j.neucom.2019.10.102] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
37
|
Abadi E, Segars WP, Tsui BMW, Kinahan PE, Bottenus N, Frangi AF, Maidment A, Lo J, Samei E. Virtual clinical trials in medical imaging: a review. J Med Imaging (Bellingham) 2020; 7:042805. [PMID: 32313817 PMCID: PMC7148435 DOI: 10.1117/1.jmi.7.4.042805] [Citation(s) in RCA: 95] [Impact Index Per Article: 19.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2019] [Accepted: 03/23/2020] [Indexed: 12/13/2022] Open
Abstract
The accelerating complexity and variety of medical imaging devices and methods have outpaced the ability to evaluate and optimize their design and clinical use. This is a significant and increasing challenge for both scientific investigations and clinical applications. Evaluations would ideally be done using clinical imaging trials. These experiments, however, are often not practical due to ethical limitations, expense, time requirements, or lack of ground truth. Virtual clinical trials (VCTs) (also known as in silico imaging trials or virtual imaging trials) offer an alternative means to efficiently evaluate medical imaging technologies virtually. They do so by simulating the patients, imaging systems, and interpreters. The field of VCTs has been constantly advanced over the past decades in multiple areas. We summarize the major developments and current status of the field of VCTs in medical imaging. We review the core components of a VCT: computational phantoms, simulators of different imaging modalities, and interpretation models. We also highlight some of the applications of VCTs across various imaging modalities.
Collapse
Affiliation(s)
- Ehsan Abadi
- Duke University, Department of Radiology, Durham, North Carolina, United States
| | - William P. Segars
- Duke University, Department of Radiology, Durham, North Carolina, United States
| | - Benjamin M. W. Tsui
- Johns Hopkins University, Department of Radiology, Baltimore, Maryland, United States
| | - Paul E. Kinahan
- University of Washington, Department of Radiology, Seattle, Washington, United States
| | - Nick Bottenus
- Duke University, Department of Biomedical Engineering, Durham, North Carolina, United States
- University of Colorado Boulder, Department of Mechanical Engineering, Boulder, Colorado, United States
| | - Alejandro F. Frangi
- University of Leeds, School of Computing, Leeds, United Kingdom
- University of Leeds, School of Medicine, Leeds, United Kingdom
| | - Andrew Maidment
- University of Pennsylvania, Department of Radiology, Philadelphia, Pennsylvania, United States
| | - Joseph Lo
- Duke University, Department of Radiology, Durham, North Carolina, United States
| | - Ehsan Samei
- Duke University, Department of Radiology, Durham, North Carolina, United States
| |
Collapse
|
38
|
Biffi C, Cerrolaza JJ, Tarroni G, Bai W, de Marvao A, Oktay O, Ledig C, Le Folgoc L, Kamnitsas K, Doumou G, Duan J, Prasad SK, Cook SA, O'Regan DP, Rueckert D. Explainable Anatomical Shape Analysis Through Deep Hierarchical Generative Models. IEEE TRANSACTIONS ON MEDICAL IMAGING 2020; 39:2088-2099. [PMID: 31944949 PMCID: PMC7269693 DOI: 10.1109/tmi.2020.2964499] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/12/2023]
Abstract
Quantification of anatomical shape changes currently relies on scalar global indexes which are largely insensitive to regional or asymmetric modifications. Accurate assessment of pathology-driven anatomical remodeling is a crucial step for the diagnosis and treatment of many conditions. Deep learning approaches have recently achieved wide success in the analysis of medical images, but they lack interpretability in the feature extraction and decision processes. In this work, we propose a new interpretable deep learning model for shape analysis. In particular, we exploit deep generative networks to model a population of anatomical segmentations through a hierarchy of conditional latent variables. At the highest level of this hierarchy, a two-dimensional latent space is simultaneously optimised to discriminate distinct clinical conditions, enabling the direct visualisation of the classification space. Moreover, the anatomical variability encoded by this discriminative latent space can be visualised in the segmentation space thanks to the generative properties of the model, making the classification task transparent. This approach yielded high accuracy in the categorisation of healthy and remodelled left ventricles when tested on unseen segmentations from our own multi-centre dataset as well as in an external validation set, and on hippocampi from healthy controls and patients with Alzheimer's disease when tested on ADNI data. More importantly, it enabled the visualisation in three-dimensions of both global and regional anatomical features which better discriminate between the conditions under exam. The proposed approach scales effectively to large populations, facilitating high-throughput analysis of normal anatomy and pathology in large-scale studies of volumetric imaging.
Collapse
|
39
|
Littlejohns TJ, Holliday J, Gibson LM, Garratt S, Oesingmann N, Alfaro-Almagro F, Bell JD, Boultwood C, Collins R, Conroy MC, Crabtree N, Doherty N, Frangi AF, Harvey NC, Leeson P, Miller KL, Neubauer S, Petersen SE, Sellors J, Sheard S, Smith SM, Sudlow CLM, Matthews PM, Allen NE. The UK Biobank imaging enhancement of 100,000 participants: rationale, data collection, management and future directions. Nat Commun 2020; 11:2624. [PMID: 32457287 PMCID: PMC7250878 DOI: 10.1038/s41467-020-15948-9] [Citation(s) in RCA: 358] [Impact Index Per Article: 71.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Accepted: 04/03/2020] [Indexed: 01/18/2023] Open
Abstract
UK Biobank is a population-based cohort of half a million participants aged 40-69 years recruited between 2006 and 2010. In 2014, UK Biobank started the world's largest multi-modal imaging study, with the aim of re-inviting 100,000 participants to undergo brain, cardiac and abdominal magnetic resonance imaging, dual-energy X-ray absorptiometry and carotid ultrasound. The combination of large-scale multi-modal imaging with extensive phenotypic and genetic data offers an unprecedented resource for scientists to conduct health-related research. This article provides an in-depth overview of the imaging enhancement, including the data collected, how it is managed and processed, and future directions.
Collapse
Affiliation(s)
| | - Jo Holliday
- Nuffield Department of Population Health, University of Oxford, Oxford, UK
| | - Lorna M Gibson
- Usher Institute of Population Health Sciences and Informatics, University of Edinburgh, Edinburgh, UK
- Department of Clinical Radiology, New Royal Infirmary of Edinburgh, Edinburgh, UK
| | | | | | - Fidel Alfaro-Almagro
- Centre for Functional MRI of the Brain, Wellcome Centre for Integrative Neuroimaging, University of Oxford, Oxford, UK
| | - Jimmy D Bell
- Research Centre for Optimal Health, University of Westminster, London, UK
| | | | - Rory Collins
- Nuffield Department of Population Health, University of Oxford, Oxford, UK
| | - Megan C Conroy
- Nuffield Department of Population Health, University of Oxford, Oxford, UK
| | - Nicola Crabtree
- Birmingham Women's and Children's NHS Foundation Trust, Birmingham, UK
| | | | - Alejandro F Frangi
- Department of Cardiovascular Sciences and Electrical Engineering, KU Leuven, Leuven, Belgium
- CISTIB Centre for Computational Imaging and Simulation Technologies in Biomedicine, Schools of Computing and Medicine, University of Leeds, Leeds, UK
| | - Nicholas C Harvey
- MRC Lifecourse Epidemiology Unit, University of Southampton, Southampton, UK
| | - Paul Leeson
- Radcliffe Department of Medicine, University of Oxford, Oxford, UK
| | - Karla L Miller
- Centre for Functional MRI of the Brain, Wellcome Centre for Integrative Neuroimaging, University of Oxford, Oxford, UK
| | - Stefan Neubauer
- Radcliffe Department of Medicine, University of Oxford, Oxford, UK
| | - Steffen E Petersen
- William Harvey Research Institute, Queen Mary University of Medicine, London, UK
| | - Jonathan Sellors
- Nuffield Department of Population Health, University of Oxford, Oxford, UK
- UK Biobank Coordinating Centre, Stockport, UK
| | | | - Stephen M Smith
- Centre for Functional MRI of the Brain, Wellcome Centre for Integrative Neuroimaging, University of Oxford, Oxford, UK
| | - Cathie L M Sudlow
- Usher Institute of Population Health Sciences and Informatics, University of Edinburgh, Edinburgh, UK
| | - Paul M Matthews
- Department of Brain Sciences, Imperial College London and UK Dementia Research Institute, London, UK
| | - Naomi E Allen
- Nuffield Department of Population Health, University of Oxford, Oxford, UK
| |
Collapse
|
40
|
Duchateau N, King AP, De Craene M. Machine Learning Approaches for Myocardial Motion and Deformation Analysis. Front Cardiovasc Med 2020; 6:190. [PMID: 31998756 PMCID: PMC6962100 DOI: 10.3389/fcvm.2019.00190] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/14/2019] [Accepted: 12/12/2019] [Indexed: 12/21/2022] Open
Abstract
Information about myocardial motion and deformation is key to differentiate normal and abnormal conditions. With the advent of approaches relying on data rather than pre-conceived models, machine learning could either improve the robustness of motion quantification or reveal patterns of motion and deformation (rather than single parameters) that differentiate pathologies. We review machine learning strategies for extracting motion-related descriptors and analyzing such features among populations, keeping in mind constraints specific to the cardiac application.
Collapse
Affiliation(s)
| | - Andrew P. King
- School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | | |
Collapse
|
41
|
Raisi-Estabragh Z, Petersen SE. Cardiovascular research highlights from the UK Biobank: opportunities and challenges. Cardiovasc Res 2019; 116:e12-e15. [PMID: 31778147 DOI: 10.1093/cvr/cvz294] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/13/2023] Open
Affiliation(s)
- Zahra Raisi-Estabragh
- Department of Advanced Cardiovascular Imaging, William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London EC1M 6BQ, UK
- Barts Heart Centre, St Bartholomew’s Hospital, Barts Health NHS Trust, West Smithfield, London EC1A 7BE, UK
| | - Steffen E Petersen
- Department of Advanced Cardiovascular Imaging, William Harvey Research Institute, NIHR Barts Biomedical Research Centre, Queen Mary University of London, Charterhouse Square, London EC1M 6BQ, UK
- Barts Heart Centre, St Bartholomew’s Hospital, Barts Health NHS Trust, West Smithfield, London EC1A 7BE, UK
| |
Collapse
|
42
|
Ehret G. Measured and Genotyped Differences in Blood Pressure and the Usefulness of Precise Extreme Phenotypes Based on Cardiovascular Magnetic Resonance. Hypertension 2019; 74:747-748. [PMID: 31476914 DOI: 10.1161/hypertensionaha.119.13238] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Affiliation(s)
- Georg Ehret
- From the Division of Cardiology, Geneva University Hospitals, Switzerland
| |
Collapse
|