1
|
Röcker D, Dietmann K, Nägler L, Su X, Fraga-García P, Schwaminger SP, Berensmeier S. Design and characterization of an electrochemically-modulated membrane chromatography device. J Chromatogr A 2024; 1718:464733. [PMID: 38364620 DOI: 10.1016/j.chroma.2024.464733] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 02/07/2024] [Accepted: 02/09/2024] [Indexed: 02/18/2024]
Abstract
Membrane separations offer a compelling alternative to traditional chromatographic methods by overcoming mass transport limitations. We introduce an additional degree of freedom in modulating membrane chromatography by using metalized membranes in a potential-driven process. Investigating the impact of a gold coating on membrane characteristics, the sputtered gold layer enhances the surface conductivity with stable electrochemical behavior. However, this comes at the expense of reduced permeability, wettability, and static binding capacity (∼ 474 µg g-1 of maleic acid). The designed device displayed a homogenous flow distribution, and the membrane electrodes exhibit predominantly capacitive behavior during potential application. Modulating the electrical potential during the adsorption and desorption phase strongly influenced the binding and elution behavior of anion-exchange membranes. Switching potentials between ±1.0 V vs. Ag/AgCl induces desorption, confirming the process principle. Elution efficiency reaches up to 58 % at -1.0 V vs. Ag/AgCl in the desorption phase without any alteration of the mobile phase. Increasing the potential perturbation ranging from +1.0 V to -1.0 V vs. Ag/AgCl resulted in reduced peak width and improved elution behavior, demonstrating the feasibility of electrochemically-modulated membrane chromatography. The developed process has great potential as a gentle and sustainable separation step in the biotechnological and chemical industry.
Collapse
Affiliation(s)
- Dennis Röcker
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Boltzmannstraße 15, Garching 85748, Germany; Munich Institute for Integrated Materials, Energy and Process Engineering, Technical University of Munich, Lichtenbergstraße 4a, Garching 85748, Germany
| | - Katharina Dietmann
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Boltzmannstraße 15, Garching 85748, Germany
| | - Larissa Nägler
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Boltzmannstraße 15, Garching 85748, Germany
| | - Xiao Su
- Department of Chemical and Biomolecular Engineering, University of Illinois Urbana-Champaign, Urbana, IL 61801, United States
| | - Paula Fraga-García
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Boltzmannstraße 15, Garching 85748, Germany
| | - Sebastian P Schwaminger
- Division of Medicinal Chemistry, Otto-Loewi Research Center, Medical University of Graz, Neue Stiftingtalstraße 6, Graz 8010, Austria; BioTechMed-Graz, Mozartgasse 12/II, Graz 8010, Austria.
| | - Sonja Berensmeier
- Chair of Bioseparation Engineering, TUM School of Engineering and Design, Technical University of Munich, Boltzmannstraße 15, Garching 85748, Germany; Munich Institute for Integrated Materials, Energy and Process Engineering, Technical University of Munich, Lichtenbergstraße 4a, Garching 85748, Germany.
| |
Collapse
|
2
|
Osuofa J, Husson SM. Comparative Evaluation of Commercial Protein A Membranes for the Rapid Purification of Antibodies. MEMBRANES 2023; 13:511. [PMID: 37233572 PMCID: PMC10220532 DOI: 10.3390/membranes13050511] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/11/2023] [Revised: 05/05/2023] [Accepted: 05/09/2023] [Indexed: 05/27/2023]
Abstract
Protein A chromatography is ubiquitous to antibody purification. The high specificity of Protein A for binding the Fc-region of antibodies and related products enables unmatched clearance of process impurities like host cell proteins, DNA, and virus particles. A recent development is the commercialization of research-scale Protein A membrane chromatography products that can perform capture step purification with short residence times (RT) on the order of seconds. This study investigates process-relevant performance and physical properties of four Protein A membranes: Purilogics Purexa™ PrA, Gore® Protein Capture Device, Cytiva HiTrap™ Fibro PrismA, and Sartorius Sartobind® Protein A. Performance metrics include dynamic binding capacity, equilibrium binding capacity, regeneration-reuse, impurity clearance, and elution volumes. Physical properties include permeability, pore diameter, specific surface area, and dead volume. Key results indicate that all membranes except the Gore® Protein Capture Device operate with flow rate-independent binding capacities; the Purilogics Purexa™ PrA and Cytiva HiTrap Fibro™ PrismA have binding capacities on par with resins, with orders of magnitude faster throughput; and dead volume and hydrodynamics play major roles in elution behavior. Results from this study will enable bioprocess scientists to understand the ways that Protein A membranes can fit into their antibody process development strategies.
Collapse
Affiliation(s)
| | - Scott M. Husson
- Department of Chemical and Biomolecular Engineering, Clemson University, Clemson, SC 29634, USA
| |
Collapse
|
3
|
Roshankhah R, Pelton R, Ghosh R. Optimization of fluid flow in membrane chromatography devices using computational fluid dynamic simulations. J Chromatogr A 2023; 1699:464030. [PMID: 37137192 DOI: 10.1016/j.chroma.2023.464030] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2023] [Revised: 04/22/2023] [Accepted: 04/25/2023] [Indexed: 05/05/2023]
Abstract
Flow uniformity within the device is critically important in membrane chromatography. Recent studies have shown that the design of the device has a significant impact on flow uniformity, and thereby on separation efficiency. The main premise of this work is that computational fluid dynamics (CFD) could serve as a fast and inexpensive tool for preliminary optimization of the design of a membrane chromatography device. CFD also helps in identifying factors that affect flow uniformity. In this paper, CFD is used to compare the fluidic attributes of conventional membrane chromatography devices such as the stacked disc and radial flow devices with those of more recently developed ones such as the different versions of the laterally-fed membrane chromatography (LFMC) device. These are compared based on pulse tracer solute dispersion, which is a useful metric for measuring flow uniformity, and is thereby a good predictor of chromatographic separation performance. The poor separation performance typically observed with conventional membrane chromatography devices could be attributed to the high degree of solute dispersion within these devices. CFD is then used to analyze the impact of factors such as membrane aspect ratio, and channel dimensions on the performance of z2-laterally-fed membrane chromatography (z2LFMC) devices. The results discussed in the paper demonstrate that CFD could indeed serve as a powerful optimization and performance prediction tool for membrane chromatography.
Collapse
Affiliation(s)
- Roxana Roshankhah
- Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L7, Canada
| | - Robert Pelton
- Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L7, Canada
| | - Raja Ghosh
- Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, ON L8S 4L7, Canada.
| |
Collapse
|
4
|
Butani N, Xu Y, Pan S, Durocher Y, Ghosh R. A fast, efficient, and scalable method for purifying recombinant SARS-CoV-2 spike protein. J Chromatogr B Analyt Technol Biomed Life Sci 2023; 1215:123579. [PMID: 36603473 PMCID: PMC9810479 DOI: 10.1016/j.jchromb.2022.123579] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/31/2022] [Revised: 12/15/2022] [Accepted: 12/17/2022] [Indexed: 12/24/2022]
Abstract
Recombinant SARS-CoV-2 trimeric spike protein produced by mammalian cell culture is a potential candidate for a COVID-19 vaccine. However, this protein is much larger than most typical biopharmaceutical proteins and its large-scale manufacture is therefore challenging. Particularly, its purification using resin-based chromatography is difficult as the diffusive transport of this protein to and from its binding site within the pores of the stationary phase particles is slow. Therefore, very low flow rates need to be used during binding and elution, and this slows down the purification process. Also, due to its large size, the binding capacity of this protein on resin-based media is low. Membrane chromatography is an efficient and scalable technique for purifying biopharmaceuticals. The predominant mode of solute transport in a membrane is convective and hence it is considered better than resin-based chromatography for purifying large proteins. In this paper, we propose a membrane chromatography-based purification method for fast and scalable manufacture of recombinant SARS-CoV-2 trimeric spike protein. A combination of cation exchange z2 laterally-fed membrane chromatography and size exclusion chromatography was found to be suitable for obtaining a homogeneous spike protein sample from mammalian cell culture supernatant. The proposed method is both fast and scalable and could be explored as a method for manufacturing vaccine grade spike protein.
Collapse
Affiliation(s)
- Nikhila Butani
- Department of Chemical Engineering, McMaster University, Hamilton, ON L8S 4L7, Canada
| | - Yating Xu
- Department of Chemical Engineering, McMaster University, Hamilton, ON L8S 4L7, Canada
| | - Si Pan
- Department of Chemical Engineering, McMaster University, Hamilton, ON L8S 4L7, Canada
| | - Yves Durocher
- National Research Council of Canada, Montreal, QC H4P 2R2, Canada; Département de biochimie et médecine moléculaire, Faculté de médecine, Université de Montréal, Montreal, QC H3C 3J7, Canada
| | - Raja Ghosh
- Department of Chemical Engineering, McMaster University, Hamilton, ON L8S 4L7, Canada.
| |
Collapse
|
5
|
Chen J, Yu B, Cong H, Shen Y. Recent development and application of membrane chromatography. Anal Bioanal Chem 2023; 415:45-65. [PMID: 36131143 PMCID: PMC9491666 DOI: 10.1007/s00216-022-04325-8] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Revised: 08/29/2022] [Accepted: 09/05/2022] [Indexed: 01/11/2023]
Abstract
Membrane chromatography is mainly used for the separation and purification of proteins and biological macromolecules in the downstream processing process, also applications in sewage disposal. Membrane chromatography is recognized as an effective alternative to column chromatography because it significantly improves chromatography from affinity, hydrophobicity, and ion exchange; the development status of membrane chromatography in membrane matrix and membrane equipment is thoroughly discussed, and the applications of protein capture and intermediate purification, virus, monoclonal antibody purification, water treatment, and others are summarized. This review will provide value for the exploration and potential application of membrane chromatography.
Collapse
Affiliation(s)
- Jing Chen
- Institute of Biomedical Materials and Engineering, College of Materials Science and Engineering, College of Chemistry and Chemical Engineering, Qingdao University, Qingdao, 266071, China
| | - Bing Yu
- Institute of Biomedical Materials and Engineering, College of Materials Science and Engineering, College of Chemistry and Chemical Engineering, Qingdao University, Qingdao, 266071, China
- State Key Laboratory of Bio-Fibers and Eco-Textiles, Qingdao University, Qingdao, 266071, China
| | - Hailin Cong
- Institute of Biomedical Materials and Engineering, College of Materials Science and Engineering, College of Chemistry and Chemical Engineering, Qingdao University, Qingdao, 266071, China.
- State Key Laboratory of Bio-Fibers and Eco-Textiles, Qingdao University, Qingdao, 266071, China.
| | - Youqing Shen
- Institute of Biomedical Materials and Engineering, College of Materials Science and Engineering, College of Chemistry and Chemical Engineering, Qingdao University, Qingdao, 266071, China
- Key Laboratory of Biomass Chemical Engineering of Ministry of Education, Center for Bionanoengineering, and Department of Chemical and Biological Engineering, Zhejiang University, Hangzhou, 310027, Zhejiang, China
| |
Collapse
|
6
|
Abstract
Membrane chromatography (MC) is an emerging bioseparation technology combining the principles of membrane filtration and chromatography. In this process, one type of molecule is adsorbed in the stationary phase, whereas the other type of molecule is passed through the membrane pores without affecting the adsorbed molecule. In subsequent the step, the adsorbed molecule is recovered by an elution buffer with a unique ionic strength and pH. Functionalized microfiltration membranes are usually used in radial flow, axial flow, and lateral flow membrane modules in MC systems. In the MC process, the transport of a solute to a stationary phase is mainly achieved through convection and minimum pore diffusion. Therefore, mass transfer resistance and pressure drop become insignificant. Other characteristics of MC systems are a minimum clogging tendency in the stationary phase, the capability of operating with a high mobile phase flow rate, and the disposable (short term) application of stationary phase. The development and application of MC systems for the fractionation of individual proteins from whey for investigation and industrial-scale production are promising. A significant income from individual whey proteins together with the marketing of dairy foods may provide a new commercial outlook in dairy industry. In this review, information about the development of a MC system and its applications for the fractionation of individual protein from whey are presented in comprehensive manner.
Collapse
|
7
|
Chen G, Butani N, Ghosh R. Fast and high-resolution fractionation of positional isomers of a PEGylated protein using membrane chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2022; 1203:123292. [DOI: 10.1016/j.jchromb.2022.123292] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Revised: 03/28/2022] [Accepted: 05/08/2022] [Indexed: 10/18/2022]
|
8
|
Yang X, Merenda A, AL-Attabi R, Dumée LF, Zhang X, Thang SH, Pham H, Kong L. Towards next generation high throughput ion exchange membranes for downstream bioprocessing: A review. J Memb Sci 2022. [DOI: 10.1016/j.memsci.2022.120325] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
9
|
Ghosh R. Ultrahigh speed, ultrahigh resolution preparative separation of protein biopharmaceuticals using membrane chromatography. J Sep Sci 2022; 45:2024-2033. [PMID: 35353929 DOI: 10.1002/jssc.202200183] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2022] [Revised: 03/24/2022] [Accepted: 03/25/2022] [Indexed: 11/06/2022]
Abstract
This paper discusses ultrahigh speed, ultrahigh resolution preparative protein separation using an in-house designed membrane chromatography device. The performance of the membrane chromatography device was systematically compared with an equivalent resin-packed preparative column. Experiments carried out using model proteins showed that membrane chromatography gave more than 4-times greater resolution than the preparative column, while at the same time being more than 19-times faster. Membrane chromatography was therefore a better option, not only in terms of higher productivity, but also in terms of higher product purity. Membrane chromatography was also superior in terms of resolving and presenting tracer impurity peaks in the chromatogram. Experiments carried out using monoclonal antibody samples showed that membrane chromatography was suitable to ultrahigh speed, ultrahigh resolution fractionation of charge variants. This paper highlights and explains the need for proper device design for enabling the use of membrane chromatography for efficient purification of protein biopharmaceuticals. This article is protected by copyright. All rights reserved.
Collapse
Affiliation(s)
- Raja Ghosh
- Department of Chemical Engineering, McMaster University, Canada
| |
Collapse
|
10
|
Kawka K, Wilton AN, Redmond EJ, Medina MFC, Lichty BD, Ghosh R, Latulippe DR. Comparison of the performance of anion exchange membrane materials for adenovirus purification using laterally-fed membrane chromatography. Biochem Eng J 2022. [DOI: 10.1016/j.bej.2022.108417] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/02/2022]
|
11
|
Kilmartin CP, Ouimet JA, Dowling AW, Phillip WA. Staged Diafiltration Cascades Provide Opportunities to Execute Highly Selective Separations. Ind Eng Chem Res 2021. [DOI: 10.1021/acs.iecr.1c02984] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- Cara P. Kilmartin
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, Indiana 46556, United States
| | - Jonathan Aubuchon Ouimet
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, Indiana 46556, United States
| | - Alexander W. Dowling
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, Indiana 46556, United States
| | - William A. Phillip
- Department of Chemical and Biomolecular Engineering, University of Notre Dame, Notre Dame, Indiana 46556, United States
| |
Collapse
|
12
|
Chen G, Pagano J, Yu D, Ghose S, Li Z, Ghosh R. Fast and high-resolution purification of a PEGylated protein using a z 2 laterally-fed membrane chromatography device. J Chromatogr A 2021; 1652:462375. [PMID: 34256267 DOI: 10.1016/j.chroma.2021.462375] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 06/19/2021] [Accepted: 06/24/2021] [Indexed: 11/28/2022]
Abstract
PEGylated proteins comprise a class of value-added biopharmaceuticals. High-resolution separation techniques are required for the purification of these molecules. In this study, we discuss the application of a newly developed z2 laterally-fed membrane chromatography (or z2LFMC) device for carrying out high-resolution purification of a PEGylated protein drug. The device used in the current study contained a stack of anion exchange (Q) membranes. The membrane bed-height of this z2LFMC device being small, it could be operated at very high flow rates, at relatively low back pressures. The primary goal was to speedily and efficiently separate a mono-PEGylated protein from impurities present in the PEGylation reaction mixture. A resin-based anion exchange column having the same ligand and bed-volume was used as the control device. The purification performance of the z2LFMC device and the control column were compared terms of resolution, recovery and purity. The z2LFMC device outperformed the control column in terms of every metric compared in this study. Higher purity (85.4% as opposed to 77.9%) and higher recovery (28% greater) of the target mono-PEGylated protein were obtained using the z2LFMC device at 20-time higher speed. These results clearly demonstrate that the z2LFMC device could be a faster and more efficient alternative to resin-based columns for purification of biopharmaceuticals.
Collapse
Affiliation(s)
- Guoqiang Chen
- Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L7, Canada
| | - John Pagano
- Biologics Process Development, Bristol-Myers Squibb, 3510F-BDB231, 38 Jackson Road, Devens MA 01434, United States
| | - Deqiang Yu
- Biologics Process Development, Bristol-Myers Squibb, 3510F-BDB231, 38 Jackson Road, Devens MA 01434, United States
| | - Sanchayita Ghose
- Biologics Process Development, Bristol-Myers Squibb, 3510F-BDB231, 38 Jackson Road, Devens MA 01434, United States
| | - Zhengjian Li
- Biologics Process Development, Bristol-Myers Squibb, 3510F-BDB231, 38 Jackson Road, Devens MA 01434, United States
| | - Raja Ghosh
- Department of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L7, Canada.
| |
Collapse
|
13
|
|
14
|
Kawka K, Wilton AN, Madadkar P, Medina MFC, Lichty BD, Ghosh R, Latulippe DR. Integrated development of enzymatic DNA digestion and membrane chromatography processes for the purification of therapeutic adenoviruses. Sep Purif Technol 2021. [DOI: 10.1016/j.seppur.2020.117503] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/26/2023]
|
15
|
Ghosh R, Chen G, Roshankhah R, Umatheva U, Gatt P. A z2 laterally-fed membrane chromatography device for fast high-resolution purification of biopharmaceuticals. J Chromatogr A 2020; 1629:461453. [DOI: 10.1016/j.chroma.2020.461453] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2020] [Revised: 08/04/2020] [Accepted: 08/05/2020] [Indexed: 01/06/2023]
|
16
|
Marioli M, Kok WT. Continuous asymmetrical flow field-flow fractionation for the purification of proteins and nanoparticles. Sep Purif Technol 2020. [DOI: 10.1016/j.seppur.2020.116744] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
17
|
Ghosh R, Chen G, Umatheva U, Gatt P. A flow distribution and collection feature for ensuring scalable uniform flow in a chromatography device. J Chromatogr A 2020; 1618:460892. [DOI: 10.1016/j.chroma.2020.460892] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2019] [Revised: 12/28/2019] [Accepted: 01/14/2020] [Indexed: 01/05/2023]
|
18
|
Simulation and experimental study of the transport of protein bands through cuboid packed-bed devices during chromatographic separations. J Chromatogr A 2020; 1615:460764. [DOI: 10.1016/j.chroma.2019.460764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2019] [Accepted: 12/02/2019] [Indexed: 11/22/2022]
|
19
|
Umatheva U, Chen G, Ghosh R. Computational fluid dynamic (CFD) simulation of a cuboid packed-bed chromatography device. Chem Eng Res Des 2019. [DOI: 10.1016/j.cherd.2019.10.005] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
20
|
An annular-flow, hollow-fiber membrane chromatography device for fast, high-resolution protein separation at low pressure. J Memb Sci 2019. [DOI: 10.1016/j.memsci.2019.117305] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
|
21
|
Madadkar P, Sadavarte R, Ghosh R. Performance Comparison of a Laterally-Fed Membrane Chromatography (LFMC) Device with a Commercial Resin Packed Column. MEMBRANES 2019; 9:E138. [PMID: 31671843 PMCID: PMC6918161 DOI: 10.3390/membranes9110138] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/05/2019] [Revised: 10/17/2019] [Accepted: 10/24/2019] [Indexed: 11/17/2022]
Abstract
The use of conventional membrane adsorbers such as radial flow devices is largely restricted to flow-through applications, such as virus and endotoxin removal, as they fail to give acceptable resolution in bind-and-elute separations. Laterally-fed membrane chromatography or LFMC devices have been specifically developed to combine high-speed with high-resolution. In this study, an LFMC device containing a stack of strong cation exchange membranes was compared with an equivalent resin packed column. Preliminary characterization experiments showed that the LFMC device had a significantly greater number of theoretical plates per metre than the column. These devices were used to separate a ternary model protein mixture consisting of ovalbumin, conalbumin and lysozyme. The resolution obtained with the LFMC device was better than that obtained with the column. For instance, the LFMC device could resolve lysozyme dimer from lysozyme monomer, which was not possible using the column. In addition, the LFMC device could be operated at lower pressure and at significantly higher flow rates. The devices were then compared based on an application case study, i.e., preparative separation of monoclonal antibody charge variants. The LFMC device gave significantly better separation of these variants than the column.
Collapse
Affiliation(s)
- Pedram Madadkar
- Department of Chemical Engineering, McMaster University, 1280 Main Street W., Hamilton, ON L8S 4L8, Canada.
| | - Rahul Sadavarte
- Department of Chemical Engineering, McMaster University, 1280 Main Street W., Hamilton, ON L8S 4L8, Canada.
| | - Raja Ghosh
- Department of Chemical Engineering, McMaster University, 1280 Main Street W., Hamilton, ON L8S 4L8, Canada.
| |
Collapse
|
22
|
Enhancing the efficiency of disc membrane chromatography modules by using a flow directing layer. J Memb Sci 2019. [DOI: 10.1016/j.memsci.2019.03.026] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
23
|
Velali E, Stute B, Leuthold M, von Lieres E. Model-based performance analysis and scale-up of membrane adsorbers with a cassettes format designed for parallel operation. Chem Eng Sci 2018. [DOI: 10.1016/j.ces.2018.07.020] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
24
|
Effect of the Length-to-Width Aspect Ratio of a Cuboid Packed-Bed Device on Efficiency of Chromatographic Separation. Processes (Basel) 2018. [DOI: 10.3390/pr6090160] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/31/2023] Open
Abstract
In recent papers we have discussed the use of cuboid packed-bed devices as alternative to columns for chromatographic separations. These devices address some of the major flow distribution challenges faced by preparative columns used for process-scale purification of biologicals. Our previous studies showed that significant improvements in separation metrics such as the number of theoretical plates, peak shape, and peak resolution in multi-protein separation could be achieved. However, the length-to-width aspect ratio of a cuboid packed-bed device could potentially affect its performance. A systematic comparison of six cuboid packed-bed devices having different length-to-width aspect ratios showed that it had a significant effect on separation performance. The number of theoretical plates per meter in the best-performing cuboid packed-bed device was about 4.5 times higher than that in its equivalent commercial column. On the other hand, the corresponding number in the worst-performing cuboid-packed bed was lower than that in the column. A head-to-head comparison of the best-performing cuboid packed bed and its equivalent column was carried out. Performance metrics compared included the widths and dispersion indices of flow-through and eluted protein peaks. The optimized cuboid packed-bed device significantly outperformed its equivalent column with regards to all these attributes.
Collapse
|
25
|
Umatheva U, Madadkar P, Selvaganapathy PR, Ghosh R. Computational fluid dynamic (CFD) simulation of laterally-fed membrane chromatography. Chem Eng Res Des 2018. [DOI: 10.1016/j.cherd.2018.07.026] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
|
26
|
Madadkar P, Yu Z, Wildfong J, Ghosh R. Comparison of membrane chromatography devices in laboratory-scale preparative flow-through separation of a recombinant protein. SEP SCI TECHNOL 2018. [DOI: 10.1080/01496395.2018.1481090] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Affiliation(s)
- Pedram Madadkar
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| | - Zhou Yu
- Bioprocess Research and Development, Sanofi Pasteur, Toronto, Ontario, Canada
| | - Jenny Wildfong
- Bioprocess Research and Development, Sanofi Pasteur, Toronto, Ontario, Canada
| | - Raja Ghosh
- Department of Chemical Engineering, McMaster University, Hamilton, Ontario, Canada
| |
Collapse
|
27
|
Effects of process parameters on the efficiency of chromatographic separations using a cuboid packed-bed device. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1086:23-28. [DOI: 10.1016/j.jchromb.2018.04.002] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2017] [Revised: 02/26/2018] [Accepted: 04/03/2018] [Indexed: 11/23/2022]
|
28
|
|
29
|
Feasibility study for high-resolution multi-component separation of protein mixture using a cation-exchange cuboid packed-bed device. J Chromatogr A 2018; 1549:25-30. [DOI: 10.1016/j.chroma.2018.03.029] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/22/2017] [Revised: 02/19/2018] [Accepted: 03/14/2018] [Indexed: 01/09/2023]
|
30
|
Sadavarte R, Madadkar P, Filipe CDM, Ghosh R. Rapid preparative separation of monoclonal antibody charge variants using laterally-fed membrane chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2018; 1073:27-33. [DOI: 10.1016/j.jchromb.2017.12.003] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/12/2017] [Revised: 11/25/2017] [Accepted: 12/02/2017] [Indexed: 11/17/2022]
|
31
|
Ghosh R, Chen G. Mathematical modelling and evaluation of performance of cuboid packed-bed devices for chromatographic separations. J Chromatogr A 2017; 1515:138-145. [DOI: 10.1016/j.chroma.2017.07.088] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2017] [Revised: 07/21/2017] [Accepted: 07/28/2017] [Indexed: 10/19/2022]
|
32
|
Madadkar P, Sadavarte R, Butler M, Durocher Y, Ghosh R. Preparative separation of monoclonal antibody aggregates by cation-exchange laterally-fed membrane chromatography. J Chromatogr B Analyt Technol Biomed Life Sci 2017; 1055-1056:158-164. [DOI: 10.1016/j.jchromb.2017.04.036] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2017] [Revised: 04/17/2017] [Accepted: 04/20/2017] [Indexed: 01/03/2023]
|
33
|
Madadkar P, Umatheva U, Hale G, Durocher Y, Ghosh R. Ultrafast Separation and Analysis of Monoclonal Antibody Aggregates Using Membrane Chromatography. Anal Chem 2017; 89:4716-4720. [PMID: 28345870 DOI: 10.1021/acs.analchem.7b00580] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Pedram Madadkar
- Department
of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L7, Canada
| | - Umatheny Umatheva
- Department
of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L7, Canada
| | - Geoff Hale
- Freelance Scientist, Oxford OX3 0SJ, United Kingdom
| | - Yves Durocher
- National Research Council of Canada, Montreal, Quebec H4P 2R2, Canada
| | - Raja Ghosh
- Department
of Chemical Engineering, McMaster University, 1280 Main Street West, Hamilton, Ontario L8S 4L7, Canada
| |
Collapse
|
34
|
Singh N, Arunkumar A, Peck M, Voloshin AM, Moreno AM, Tan Z, Hester J, Borys MC, Li ZJ. Development of adsorptive hybrid filters to enable two-step purification of biologics. MAbs 2016; 9:350-363. [PMID: 27929735 PMCID: PMC5297532 DOI: 10.1080/19420862.2016.1267091] [Citation(s) in RCA: 14] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/27/2016] [Revised: 11/18/2016] [Accepted: 11/28/2016] [Indexed: 10/20/2022] Open
Abstract
Recent progress in mammalian cell culture process has resulted in significantly increased product titers, but also a substantial increase in process- and product-related impurities. Due to the diverse physicochemical properties of these impurities, there is constant need for new technologies that offer higher productivity and improved economics without sacrificing the process robustness required to meet final drug substance specifications. Here, we examined the use of new synthetic adsorptive hybrid filters (AHF) modified with the high binding capacity of quaternary amine (Emphaze™ AEX) and salt-tolerant biomimetic (Emphaze™ ST-AEX) ligands for clearance of process-related impurities like host cell protein (HCP), residual DNA, and virus. The potential to remove soluble aggregates was also examined. Our aim was to develop a mechanistic understanding of the interactions governing adsorptive removal of impurities during filtration by evaluating the effect of various filter types, feed streams, and process conditions on impurity removal. The ionic capacity of these filters was measured and correlated with their ability to remove impurities for multiple molecules. The ionic capacity of AHF significantly exceeded that of traditional adsorptive depth filters (ADF) by 40% for the Emphaze™ AEX and by 700% for the Emphaze™ ST-AEX, providing substantially higher reduction of soluble anionic impurities, including DNA, HCPs and model virus. Nevertheless, we determined that ADF with filter aid provided additional hydrophobic functionality that resulted in removal of higher molecular weight species than AHF. Implementing AHF demonstrated improved process-related impurity removal and viral clearance after Protein A chromatography and enabled a two-step purification process. The consequences of enhanced process performance are far reaching because it allows the downstream polishing train to be restructured and simplified, and chromatographic purity standards to be met with a reduced number of chromatographic steps.
Collapse
Affiliation(s)
- Nripen Singh
- Biologics Development, Global Manufacturing and Supply, Bristol-Myers Squibb Company, Devens, MA, USA
| | - Abhiram Arunkumar
- Biologics Development, Global Manufacturing and Supply, Bristol-Myers Squibb Company, Devens, MA, USA
| | - Michael Peck
- Biologics Development, Global Manufacturing and Supply, Bristol-Myers Squibb Company, Devens, MA, USA
| | - Alexei M. Voloshin
- Life Science Process Technologies, 3M Purification Inc., St Paul, MN, USA
| | - Angela M. Moreno
- Life Science Process Technologies, 3M Purification Inc., St Paul, MN, USA
| | - Zhijun Tan
- Biologics Development, Global Manufacturing and Supply, Bristol-Myers Squibb Company, Devens, MA, USA
| | - Jonathan Hester
- Life Science Process Technologies, 3M Purification Inc., St Paul, MN, USA
| | - Michael C. Borys
- Biologics Development, Global Manufacturing and Supply, Bristol-Myers Squibb Company, Devens, MA, USA
| | - Zheng Jian Li
- Biologics Development, Global Manufacturing and Supply, Bristol-Myers Squibb Company, Devens, MA, USA
| |
Collapse
|
35
|
Madadkar P, Nino SL, Ghosh R. High-resolution, preparative purification of PEGylated protein using a laterally-fed membrane chromatography device. J Chromatogr B Analyt Technol Biomed Life Sci 2016; 1035:1-7. [DOI: 10.1016/j.jchromb.2016.09.014] [Citation(s) in RCA: 18] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2016] [Revised: 09/05/2016] [Accepted: 09/13/2016] [Indexed: 11/28/2022]
|
36
|
Ghosh R. Using a box instead of a column for process chromatography. J Chromatogr A 2016; 1468:164-172. [DOI: 10.1016/j.chroma.2016.09.044] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2016] [Revised: 09/19/2016] [Accepted: 09/20/2016] [Indexed: 01/31/2023]
|