1
|
Ajdari B, Madrakian T, Afkhami A. Development of an electrochemical sensor utilizing MWCNs-poly(2-aminothiophenol) @AgNPs nanocomposite for the simultaneous determination of Pb 2+ and Cd 2+ in food samples. Food Chem 2025; 477:143529. [PMID: 40023026 DOI: 10.1016/j.foodchem.2025.143529] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2024] [Revised: 02/19/2025] [Accepted: 02/19/2025] [Indexed: 03/04/2025]
Abstract
This study focuses on the synthesis and characterization of the Multiwall Carbon Nanotubes-Poly(2-aminothiophenol) @silver nanoparticles nanocomposite (MWCNTs-PATP@AgNPs) using different analytical methods. The synthesized MWCNTs-PATP@AgNPs served as an electrocatalytic modifier, enabling the highly selective and sensitive detection of Pb2+ and Cd2+ ions at nanomolar levels using square wave anodic stripping voltammetry. The concentration of MWCNTs- PATP @AgNPs, the type and concentration of the electrolyte, the solution's pH, and the preconcentration conditions, were systematically optimized. A linear response was observed for Pb2+ and Cd2+ within the ranges of 0.5-60.0 nmolL-1 and 8.0-50.0 nmol L-1, respectively, with detection limits of 0.125 nmol L-1 for Pb2+ and 1.47 nmol L-1 for Cd2+. Furthermore, the MWCNTs-PATP@AgNPs sensor demonstrated the capability to selectively detect these target metals in the presence of various common interfering species. The sensor was effectively utilized for the detection of Pb2+ and Cd2+ ions across various real samples.
Collapse
Affiliation(s)
- Beheshteh Ajdari
- Department of Analytical Chemistry, Faculty of Chemistry and Petroleum Sciences, Bu-Ali Sina University, Hamedan, 6517838695, Iran
| | - Tayyebeh Madrakian
- Department of Analytical Chemistry, Faculty of Chemistry and Petroleum Sciences, Bu-Ali Sina University, Hamedan, 6517838695, Iran.
| | - Abbas Afkhami
- Department of Analytical Chemistry, Faculty of Chemistry and Petroleum Sciences, Bu-Ali Sina University, Hamedan, 6517838695, Iran
| |
Collapse
|
2
|
Rafiq K, Sadia I, Abid MZ, Waleed MZ, Rauf A, Hussain E. Scientific Insights into the Quantum Dots (QDs)-Based Electrochemical Sensors for State-of-the-Art Applications. ACS Biomater Sci Eng 2024; 10:7268-7313. [PMID: 39499739 DOI: 10.1021/acsbiomaterials.4c01256] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2024]
Abstract
Size-dependent optical and electronic properties are unique characteristics of quantum dots (QDs). A significant advantage is the quantum confinement effect that allows their precise tuning to achieve required characteristics and behavior for the targeted applications. Regarding the aforementioned factors, QDs-based sensors have exhibited dramatic potential for the diverse and advanced applications. For example, QDs-based devices have been potentially utilized for bioimaging, drug delivery, cancer therapy, and environmental remediation. In recent years, use of QDs-based electrochemical sensors have been further extended in other areas like gas sensing, metal ion detection, monitoring of organic pollutants, and detection of radioactive isotopes. Objective of this study is to rationalize the QDs-based electrochemical sensors for state-of-the-art applications. This review article comprehensively illustrates the importance of aforementioned devices along with sources from which QDs devices have been formulated and fabricated. Other distinct features of QDs devices are associated with their extremely high active surfaces, inherent ability of reproducibility, sensitivity, and selectivity for the targeted analyte detection. In this review, major categories of QD materials along with justification of their key roles in electrochemical devices have been demonstrated and discussed. All categories have been evaluated with special emphasis on the advantages and drawbacks/challenges associated with QD materials. However, in the interests of readers and researchers, recent improvements also have been included and discussed. On the evaluation, it has been concluded that despite significant challenges, QDs-based electrochemical sensors exhibit excellent performances for state-of-the-art and targeted applications.
Collapse
Affiliation(s)
- Khezina Rafiq
- Institute of Chemistry, Inorganic Materials Laboratory 52S, The Islamia University of Bahawalpur, Bahawalpur 63100, Pakistan
| | - Iqra Sadia
- Institute of Chemistry, Inorganic Materials Laboratory 52S, The Islamia University of Bahawalpur, Bahawalpur 63100, Pakistan
| | - Muhammad Zeeshan Abid
- Institute of Chemistry, Inorganic Materials Laboratory 52S, The Islamia University of Bahawalpur, Bahawalpur 63100, Pakistan
| | - Muhammad Zaryab Waleed
- Institute of Chemistry, Inorganic Materials Laboratory 52S, The Islamia University of Bahawalpur, Bahawalpur 63100, Pakistan
| | - Abdul Rauf
- Institute of Chemistry, Inorganic Materials Laboratory 52S, The Islamia University of Bahawalpur, Bahawalpur 63100, Pakistan
| | - Ejaz Hussain
- Institute of Chemistry, Inorganic Materials Laboratory 52S, The Islamia University of Bahawalpur, Bahawalpur 63100, Pakistan
| |
Collapse
|
3
|
Moradpour H, Forootanfar H, Ameri A, Beitollahi H. Fabrication of the carbon paste electrode modified with Trametes versicolor laccase immobilized on carboxyl functionalized multi-walled carbon nanotubes and its application for measurement of dopamine. Int J Biol Macromol 2024; 283:137891. [PMID: 39571857 DOI: 10.1016/j.ijbiomac.2024.137891] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/14/2024] [Revised: 10/16/2024] [Accepted: 11/18/2024] [Indexed: 11/29/2024]
Abstract
Dopamine (DA) shows numerous roles in a wide range of physiological and pathological processes. In this study, an immobilized laccase-derived biosensor was developed for DA detection. The carboxyl functionalized multi-walled carbon nanotubes (MWCNTs-COOH) was applied for immobilization of laccase from Trametes versicolor (TvLac). According to Plackett-Burman statistical design, the optimum conditions showed at 5 mg/mL of MWCNTs-COOH, 25 mM phosphate buffer (pH 6.0), sonication time for 15 min, 2.5 U/mg of enzyme concentration, immobilization time for 4 h at 4 °C, and rotation at 100 rpm. At these conditions, the experimental and predicted specific activities were 14.19 ± 1.41 U/mg and 13.99 ± 1.54 U/mg, respectively. The activity of immobilized TvLac was >90 % at 60 °C and pH 7.0 as well as after 10 sets of uses. The carbon paste electrode (CPE) modified with the immobilized TvLac was then fabricated, characterized and applied as a biosensor (TvLac@MWCNTs-COOH/CPE) for determination of DA. The mean of diffusion coefficient for DA was considered to be 9.1 × 10-6 cm2/s. The TvLac@MWCNTs-COOH/CPE represented a linear dynamic range of 0.005-100.0 μM with detection limit of 1.0 nM. The TvLac@MWCNTs-COOH/CPE might be introduced as a suitable sensor for monitoring of DA in real specimens which merit further studies.
Collapse
Affiliation(s)
- Hediyeh Moradpour
- Department of Chemistry, Graduate University of Advanced Technology, Kerman, Iran
| | - Hamid Forootanfar
- Pharmaceutical Sciences and Cosmetic Products Research Center, Kerman University of Medical Sciences, Kerman, Iran
| | - Atefeh Ameri
- Pharmaceutical Sciences and Cosmetic Products Research Center, Kerman University of Medical Sciences, Kerman, Iran.
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran.
| |
Collapse
|
4
|
Kamble BB, Sharma KK, Sonawane KD, Tayade SN, Grammatikos S, Reddy YVM, Reddy SL, Shin JH, Park JP. Graphitic carbon nitride-based electrochemical sensors: A comprehensive review of their synthesis, characterization, and applications. Adv Colloid Interface Sci 2024; 333:103284. [PMID: 39226798 DOI: 10.1016/j.cis.2024.103284] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2024] [Revised: 08/02/2024] [Accepted: 08/24/2024] [Indexed: 09/05/2024]
Abstract
Graphitic carbon nitride (g-C3N4) has garnered much attention as a promising 2D material in the realm of electrochemical sensors. It contains a polymeric matrix that can serve as an economical and non-toxic electrode material for the detection of a diverse range of analytes. However, its performance is impeded by a relatively limited active surface area and inherent instability. Although electrochemistry involving metal-doped g-C3N4 nanomaterials is rapidly progressing, it remains relatively unexplored. The metal doping of g-C3N4 augments the electrochemically active surface area of the resulting electrode, which has the potential to significantly enhance electrode kinetics and bolster catalytic activity. Consequentially, the main objective of this review is to provide insight into the intricacies of synthesizing and characterizing metal-doped g-C3N4. Furthermore, we comprehensively delve into the fundamental attributes of electrochemical sensors based on metal-doped g-C3N4, with a specific focus on healthcare and environmental applications. These applications encompass a meticulous exploration of detecting biomolecules, drug molecules, and organic pollutants.
Collapse
Affiliation(s)
- Bhagyashri B Kamble
- Department of Chemistry, Shivaji University, Kolhapur 416004, Maharashtra, India.
| | - Kiran Kumar Sharma
- School of Nanoscience and Biotechnology, Shivaji University, Kolhapur, Maharashtra 416004, India
| | - Kailas D Sonawane
- Department of Microbiology, Shivaji University, Kolhapur, Maharashtra 416004, India
| | - Shivaji N Tayade
- Department of Chemistry, Shivaji University, Kolhapur 416004, Maharashtra, India
| | - Sotirios Grammatikos
- ASEMlab - Laboratory of Advanced and Sustainable Engineering Materials, Department of Manufacturing and Civil Engineering, Norwegian University of Science and Technology (NTNU), Gjøvik, Norway
| | - Y Veera Manohara Reddy
- Department of Manufacturing and Civil Engineering, Norwegian University of Science and Technology (NTNU), Gjøvik, Norway; Department of Chemistry, Sri Venkateswara College, University of Delhi, New Delhi 110026, India.
| | - S Lokeswara Reddy
- Department of Bioelectronics and Biosensors, Alagappa University, Karaikudi 630003, TN, India
| | - Jae Hwan Shin
- Department of Food Science and Technology, GreenTech-Based Food Safety Research Group, BK21 Four, Chung-Ang University, 4726 Seodongdaero, Anseong 17546, Republic of Korea
| | - Jong Pil Park
- Department of Food Science and Technology, GreenTech-Based Food Safety Research Group, BK21 Four, Chung-Ang University, 4726 Seodongdaero, Anseong 17546, Republic of Korea.
| |
Collapse
|
5
|
Brycht M, Poltorak L, Baluchová S, Sipa K, Borgul P, Rudnicki K, Skrzypek S. Electrochemistry as a Powerful Tool for Investigations of Antineoplastic Agents: A Comprehensive Review. Crit Rev Anal Chem 2024; 54:1017-1108. [PMID: 35968923 DOI: 10.1080/10408347.2022.2106117] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/15/2022]
Abstract
Cancer is most frequently treated with antineoplastic agents (ANAs) that are hazardous to patients undergoing chemotherapy and the healthcare workers who handle ANAs in the course of their duties. All aspects related to hazardous oncological drugs illustrate that the monitoring of ANAs is essential to minimize the risks associated with these drugs. Among all analytical techniques used to test ANAs, electrochemistry holds an important position. This review, for the first time, comprehensively describes the progress done in electrochemistry of ANAs by means of a variety of bare or modified (bio)sensors over the last four decades (in the period of 1982-2021). Attention is paid not only to the development of electrochemical sensing protocols of ANAs in various biological, environmental, and pharmaceutical matrices but also to achievements of electrochemical techniques in the examination of the interactions of ANAs with deoxyribonucleic acid (DNA), carcinogenic cells, biomimetic membranes, peptides, and enzymes. Other aspects, including the enantiopurity studies, differentiation between single-stranded and double-stranded DNA without using any label or tag, studies on ANAs degradation, and their pharmacokinetics, by means of electrochemical techniques are also commented. Finally, concluding remarks that underline the existence of a significant niche for the basic electrochemical research that should be filled in the future are presented.
Collapse
Affiliation(s)
- Mariola Brycht
- Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, University of Lodz, Lodz, Poland
| | - Lukasz Poltorak
- Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, University of Lodz, Lodz, Poland
| | - Simona Baluchová
- Faculty of Science, Department of Analytical Chemistry, UNESCO Laboratory of Environmental Electrochemistry, Charles University, Prague 2, Czechia
- Department of Precision and Microsystems Engineering, Delft University of Technology, Delft, The Netherlands
| | - Karolina Sipa
- Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, University of Lodz, Lodz, Poland
| | - Paulina Borgul
- Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, University of Lodz, Lodz, Poland
| | - Konrad Rudnicki
- Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, University of Lodz, Lodz, Poland
| | - Sławomira Skrzypek
- Faculty of Chemistry, Department of Inorganic and Analytical Chemistry, University of Lodz, Lodz, Poland
| |
Collapse
|
6
|
Tiwari MS, Kadu AK. Thiol-based chemically modified carbon screen-printed electrode for simultaneous quantification of trace level Pb(II) and Cd(II). ANAL SCI 2024; 40:1449-1457. [PMID: 38740715 PMCID: PMC11269355 DOI: 10.1007/s44211-024-00581-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Accepted: 04/15/2024] [Indexed: 05/16/2024]
Abstract
Present work reports, the development of a novel electrochemical sensor based on a diazonium-coupling reaction and covalent attachment of the -NH2 group of cysteamine (Cyst) on screen-printed carbon electrode (SPCE), for simultaneous determination of Pb(II) and Cd(II). Initially, the in-situ generated 4-carboxyphenyl (4-CP) diazonium salt was electro-grafted to generate 4-CP/SPCE, followed by covalent bonding of terminal carboxylic group of 4-CP with -NH2 group of Cyst to give Cyst/4-CP/SPCE. The modified electrode showed an enhanced selectivity and sensitivity toward the quantification of Pb(II) and Cd(II) using square wave anodic stripping voltammetry (SWASV) without mutual interference. Under optimal experimental conditions, the newly designed sensor showed a wide linear range of 0.01 µM to 0.7 µM. The limit of detection (LOD) obtained was 0.882 nM (0.09 ppb) and 0.65 nM (0.134 ppb) for Cd(II) and Pb(II), respectively. The modified SPCE exhibited good stability, selectivity, and reproducibility. Furthermore, the sensor was successfully applied for the determination of Pb(II) and Cd(II) ions in water samples which illustrated excellent recoveries in different spiked samples and the results were in line with the standard ICP-AES analysis.
Collapse
Affiliation(s)
- Mritunjay S Tiwari
- University Department of Chemistry, University of Mumbai, Vidyanagari, Santacruz (East), Mumbai, 400 098, India
| | - Arun K Kadu
- University Department of Chemistry, University of Mumbai, Vidyanagari, Santacruz (East), Mumbai, 400 098, India.
| |
Collapse
|
7
|
Olave B. DNA nanotechnology in ionic liquids and deep eutectic solvents. Crit Rev Biotechnol 2024; 44:941-961. [PMID: 37518062 DOI: 10.1080/07388551.2023.2229950] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 04/28/2023] [Accepted: 06/01/2023] [Indexed: 08/01/2023]
Abstract
Nucleic acids have the ability to generate advanced nanostructures in a controlled manner and can interact with target sequences or molecules with high affinity and selectivity. For this reason, they have applications in a variety of nanotechnology applications, from highly specific sensors to smart nanomachines and even in other applications such as enantioselective catalysis or drug delivery systems. However, a common disadvantage is the use of water as the ubiquitous solvent. The use of nucleic acids in non-aqueous solvents offers the opportunity to create a completely new toolbox with unprecedented degrees of freedom. Ionic liquids (ILs) and deep eutectic solvents (DESs) are the most promising alternative solvents due to their unique electrolyte and solvent roles, as well as their ability to maintain the stability and functionality of nucleic acids. This review aims to be a comprehensive, critical, and accessible evaluation of how much this goal has been achieved and what are the most critical parameters for accomplishing a breakthrough.
Collapse
Affiliation(s)
- Beñat Olave
- University of the Basque Country (UPV/EHU), Donostia-San Sebastian, Spain
| |
Collapse
|
8
|
Qin X, Yin P, Zhang Y, Su M, Chen F, Xu X, Zhao J, Gui Y, Guo H, Zhao C, Zhang Z. Self-assembled ordered AuNRs-modified electrodes for simultaneous determination of dopamine and topotecan with improved data reproducibility. Mikrochim Acta 2024; 191:350. [PMID: 38806865 DOI: 10.1007/s00604-024-06441-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2024] [Accepted: 05/15/2024] [Indexed: 05/30/2024]
Abstract
Gold nanomaterials have been widely explored in electrochemical sensors due to their high catalytic property and good stability in multi-medium. In this paper, the reproducibility of the signal among batches of gold nanorods (AuNRs)-modified electrodes was investigated to improve the data stabilization and repeatability. Ordered and random self-assembled AuNRs-modified electrodes were used as electrochemical sensors for the simultaneous determination of dopamine (DA) and topotecan (TPC), with the aim of obtaining an improved signal stability in batches of electrodes and realizing the simultaneous determination of both substances. The morphology and structure of the assemblies were analyzed and characterized by UV-Vis spectra, scanning electron microscopy (SEM), transmission electron microscopy (TEM), and X-ray powder diffraction (XRD). Electrochemical studies showed that the ordered AuNRs/ITO electrodes have excellent signal reproducibility among several individuals due to the homogeneous mass transfer in the ordered arrangement of the AuNRs. Under the optimized conditions, the simultaneous detection results of DA and TPC showed good linearity in the ranges 1.75-45 μM and 1.5-40 μM, and the detection limits of DA and TPC were 0.06 μM and 0.17 μM, respectively. The results showed that the prepared ordered AuNR/ITO electrode had high sensitivity, long-term stability, and reproducibility for the simultaneous determination of DA and TPC, and it was expected to be applicable for real sample testing.
Collapse
Affiliation(s)
- Xiaoyun Qin
- School of Material and Chemical Engineering, Zhengzhou University of Light Industry, Zhengzhou, 450000, China
| | - Peijun Yin
- School of Material and Chemical Engineering, Zhengzhou University of Light Industry, Zhengzhou, 450000, China
| | - Yuhang Zhang
- School of Material and Chemical Engineering, Zhengzhou University of Light Industry, Zhengzhou, 450000, China
| | - Mingxing Su
- School of Material and Chemical Engineering, Zhengzhou University of Light Industry, Zhengzhou, 450000, China
| | - Fenghua Chen
- School of Material and Chemical Engineering, Zhengzhou University of Light Industry, Zhengzhou, 450000, China
| | - Xinru Xu
- Tianjin Key Laboratory of Molecular Optoelectronic Sciences, Department of Chemistry, School of Science, Tianjin University, Tianjin, 300072, China
| | - Jianbo Zhao
- School of Material and Chemical Engineering, Zhengzhou University of Light Industry, Zhengzhou, 450000, China
| | - Yanghai Gui
- School of Material and Chemical Engineering, Zhengzhou University of Light Industry, Zhengzhou, 450000, China
| | - Huishi Guo
- School of Material and Chemical Engineering, Zhengzhou University of Light Industry, Zhengzhou, 450000, China
| | - Chao Zhao
- Tianjin Key Laboratory of Molecular Optoelectronic Sciences, Department of Chemistry, School of Science, Tianjin University, Tianjin, 300072, China
| | - Zhen Zhang
- Tianjin Key Laboratory of Molecular Optoelectronic Sciences, Department of Chemistry, School of Science, Tianjin University, Tianjin, 300072, China.
| |
Collapse
|
9
|
Moço ACR, Gomide JAL, Flauzino JMR, Brussasco JG, Luz LFG, Soares MMCN, Madurro JM, Brito-Madurro AG. Fentogram electrochemical detection of HIV RNA based on graphene quantum dots and gold nanoparticles. J Pharm Biomed Anal 2024; 242:116025. [PMID: 38422670 DOI: 10.1016/j.jpba.2024.116025] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2023] [Revised: 01/29/2024] [Accepted: 02/07/2024] [Indexed: 03/02/2024]
Abstract
This work reports the construction of an HIV-specific genosensor through the modification of carbon screen-printed electrodes (CSPE) with graphene quantum dots decorated with L-cysteine and gold nanoparticles (cys-GQDs/AuNps). Cys-GQDs were characterized by FT-IR and UV-vis spectra and electronic properties of the modified electrodes were evaluated by cyclic voltammetry and electrochemical impedance spectroscopy. The modification of the electrode surface with cys-GQDs and AuNps increased the electrochemical performance of the electrode, improving the electron transfer of the anionic redox probe [Fe(CN)6]3-/4- on the electrochemical platform. When compared to the bare surface, the modified electrode showed a 1.7 times increase in effective electrode area and a 29 times decrease in charge transfer resistance. The genosensor response was performed by differential pulse voltammetry, monitoring the current response of the anionic redox probe, confirmed with real genomic RNA samples, making it possible to detect 1 fg/mL. In addition, the genosensor maintained its response for 60 days at room temperature. This new genosensor platform for early detection of HIV, based on the modification of the electrode surface with cys-GQDs and AuNps, discriminates between HIV-negative and positive samples, showing a low detection limit, as well as good specificity and stability, which are relevant properties for commercial application of biosensors.
Collapse
Affiliation(s)
- Anna C R Moço
- Institute of Biotechnology, Federal University of Uberlândia, 38405-319 Uberlândia, Minas Gerais, Brazil
| | - José A L Gomide
- Institute of Biotechnology, Federal University of Uberlândia, 38405-319 Uberlândia, Minas Gerais, Brazil
| | - Jose M R Flauzino
- Institute of Biotechnology, Federal University of Uberlândia, 38405-319 Uberlândia, Minas Gerais, Brazil
| | - Jéssica G Brussasco
- Institute of Biotechnology, Federal University of Uberlândia, 38405-319 Uberlândia, Minas Gerais, Brazil
| | - Luiz F G Luz
- Institute of Biotechnology, Federal University of Uberlândia, 38405-319 Uberlândia, Minas Gerais, Brazil
| | - Márcia M C N Soares
- Adolfo Lutz Institute, Regional Laboratory, 15061-020 São José do Rio Preto, São Paulo, Brazil
| | - João M Madurro
- Institute of Chemistry, Federal University of Uberlândia, 38400-902 Uberlândia, Minas Gerais, Brazil
| | - Ana G Brito-Madurro
- Institute of Biotechnology, Federal University of Uberlândia, 38405-319 Uberlândia, Minas Gerais, Brazil.
| |
Collapse
|
10
|
Ganesh PS, Elugoke SE, Lee SH, Kim SY, Ebenso EE. Smart and emerging point of care electrochemical sensors based on nanomaterials for SARS-CoV-2 virus detection: Towards designing a future rapid diagnostic tool. CHEMOSPHERE 2024; 352:141269. [PMID: 38307334 DOI: 10.1016/j.chemosphere.2024.141269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 01/08/2024] [Accepted: 01/18/2024] [Indexed: 02/04/2024]
Abstract
In the recent years, researchers from all over the world have become interested in the fabrication of advanced and innovative electrochemical and/or biosensors for respiratory virus detection with the use of nanotechnology. These fabricated sensors demonstrated a number of benefits, including precision, affordability, accessibility, and miniaturization which makes them a promising test method for point-of-care (PoC) screening for SARS-CoV-2 viral infection. In order to comprehend the principles of electrochemical sensing and the role of various types of sensing interfaces, we comprehensively explored the underlying principles of electroanalytical methods and terminologies related to it in this review. In addition, it is addressed how to fabricate electrochemical sensing devices incorporating nanomaterials as graphene, metal/metal oxides, metal organic frameworks (MOFs), MXenes, quantum dots, and polymers. We took an effort to carefully compile current developments, advantages, drawbacks, possible solutions in nanomaterials based electrochemical sensors.
Collapse
Affiliation(s)
- Pattan Siddappa Ganesh
- Interaction Laboratory, Advanced Technology Research Center, Future Convergence Engineering, Korea University of Technology and Education, Cheonan-si, Chungcheongnam-do, 330-708, Republic of Korea.
| | - Saheed Eluwale Elugoke
- Centre for Material Science, College of Science, Engineering and Technology, University of South Africa, Johannesburg 1709, South Africa; Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Johannesburg 1709, South Africa
| | - Seok-Han Lee
- Interaction Laboratory, Advanced Technology Research Center, Future Convergence Engineering, Korea University of Technology and Education, Cheonan-si, Chungcheongnam-do, 330-708, Republic of Korea
| | - Sang-Youn Kim
- Interaction Laboratory, Advanced Technology Research Center, Future Convergence Engineering, Korea University of Technology and Education, Cheonan-si, Chungcheongnam-do, 330-708, Republic of Korea.
| | - Eno E Ebenso
- Centre for Material Science, College of Science, Engineering and Technology, University of South Africa, Johannesburg 1709, South Africa; Institute for Nanotechnology and Water Sustainability (iNanoWS), College of Science, Engineering and Technology, University of South Africa, Johannesburg 1709, South Africa.
| |
Collapse
|
11
|
Yağız E, Ozyilmaz G, Ozyilmaz AT. Response surface methodology use in construction of polianiline-coated carbon paste electrode-based biosensor: Modification and characterization. Biotechnol Appl Biochem 2024; 71:147-161. [PMID: 37846169 DOI: 10.1002/bab.2528] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Accepted: 10/07/2023] [Indexed: 10/18/2023]
Abstract
In this study, the effect of amperometric glucose biosensor construction and using conditions on the current response was investigated in detail applying experimental design. Polyaniline (PANI) was synthesized on the carbon paste electrode (CPE) surface using the cyclic voltammetry technique in sodium oxalate (NaOx ) electrolyte medium, and an amperometric biosensor was constructed by immobilizing glucose oxidase (GOD). Biosensor preparation (aniline, GOD and NaOx concentrations, and scan rate) and operating conditions (pH and applied potential) were optimized by Box-Behnken and optimal designs, respectively, via State Ease Design Expert 7.0.1.1 software. ANOVA analyses showed that among the biosensor preparation parameters, the NaOx concentration has the highest effect on the current measured in the presence of glucose, whereas in the optimization of pH and potential parameters applied in current measurement studies, it has been revealed that pH has a very high effect on the measured current. Several compounds, such as MWCNT, two different ionic liquids and two different organic molecules were added to carbon paste, and, among them, 2-cyanoethylpyrrole (CPy) enhanced the efficacy highly, most probably due to its polymerization in the paste and increasing the electron transfer rate of the CPE. Sucrose- and lactose-sensitive biosensors were also constructed by co-immobilizing GOD with invertase (INV) or β-galactosidase, respectively, onto modified CPE, and sensitivities to their substrates were shown by cyclic voltammetry and impedance analysis. CPy modification caused an increase in the current values, and also Imax /KM values increased approximately 11.8, 7.83, and 2.56 times for glucose-, sucrose-, and lactose-sensitive CPEs, respectively.
Collapse
Affiliation(s)
- Esra Yağız
- Department of Chemistry, Faculty of Arts & Sciences, University of Hatay Mustafa Kemal, Hatay, Turkey
| | - Gul Ozyilmaz
- Department of Chemistry, Faculty of Arts & Sciences, University of Hatay Mustafa Kemal, Hatay, Turkey
| | - Ali Tuncay Ozyilmaz
- Department of Chemistry, Faculty of Arts & Sciences, University of Hatay Mustafa Kemal, Hatay, Turkey
| |
Collapse
|
12
|
Srivastava A, Azad UP. Nanobioengineered surface comprising carbon based materials for advanced biosensing and biomedical application. Int J Biol Macromol 2023; 253:126802. [PMID: 37690641 DOI: 10.1016/j.ijbiomac.2023.126802] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2023] [Revised: 08/30/2023] [Accepted: 09/06/2023] [Indexed: 09/12/2023]
Abstract
Carbon-based nanomaterials (CNMs) are at the cutting edge of materials science. Due to their distinctive architectures, substantial surface area, favourable biocompatibility, and reactivity to internal and/or external chemico-physical stimuli, carbon-based nanomaterials are becoming more and more significant in a wide range of applications. Numerous research has been conducted and still is going on to investigate the potential uses of carbon-based hybrid materials for diverse applications such as biosensing, bioimaging, smart drug delivery with the potential for theranostic or combinatorial therapies etc. This review is mainly focused on the classifications and synthesis of various types of CNMs and their electroanalytical application for development of efficient and ultra-sensitive electrochemical biosensors for the point of care diagnosis of fatal and severe diseases at their very initial stage. This review is mainly focused on the classification, synthesis and application of carbon-based material for biosensing applications. The integration of various types of CNMs with nanomaterials, enzymes, redox mediators and biomarkers have been used discussed in development of smart biosensing platform. We have also made an effort to discuss the future prospects for these CNMs in the biosensing area as well as the most recent advancements and applications which will be quite useful for the researchers working across the globe working specially in biosensors field.
Collapse
Affiliation(s)
- Ananya Srivastava
- Department of Chemistry, Banaras Hindu University, Varanasi 221005, Uttar Pradesh, India.
| | - Uday Pratap Azad
- Laboratory of Nanoelectrochemistry, Department of Chemistry, Guru Ghasidas Vishwavidyalaya (Central University), Bilaspur 495 009, CG, India.
| |
Collapse
|
13
|
Rashid M, Khalid M, Ashraf A, Saleem T, Shafiq I, Shakil MA, Zainab B, El-Kott AF, Yaqub M, Shafiq Z. Multicomponent synthesis of pyrido[2,3- b]pyrazine derivatives: electrochemical DNA sensing, nonlinear optical properties and biological activity. RSC Adv 2023; 13:32160-32174. [PMID: 37920758 PMCID: PMC10619479 DOI: 10.1039/d3ra05365b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/07/2023] [Accepted: 10/19/2023] [Indexed: 11/04/2023] Open
Abstract
We synthesized novel pyrido[2,3-b]pyrazin based heterocyclic compounds (4-7) and their chemical structures were ascertained by spectral techniques (NMR, FT-IR). Besides experimental investigation, density functional theory (DFT) computations with B3LYP/6-31G(d,p) level of theory were executed to obtain spectroscopic and electronic properties. Nonlinear optical (NLO) properties, frontier molecular orbitals (FMOs), UV-visible, vibrational analysis, natural bond orbitals (NBOs), transition density matrix (TDM) and density of states (DOS) analyses of molecules (4-7) were accomplished at B3LYP/6-31G (d,p) level. Global reactivity parameters (GRPs) were correlated with the band gap (Egap) values; compound 7 with lower Egap (3.444 eV), exhibited smaller value of hardness (1.722 eV) with greater softness value (0.290 eV-1). The dipole moment (μ), average polarizability 〈α〉, first (βtot) and second 〈γ〉 hyper-polarizabilities were calculated for compounds (4-7). Compound 7 showed less Egap, highest absorption wavelength and remarkable NLO response. The highest 〈α〉, βtot and 〈γ〉 values for compound 7 were observed as 3.90 × 10-23, 15.6 × 10-30 and 6.63 × 10-35 esu, respectively. High NLO response revealed that pyrido[2,3-b]pyrazin based heterocyclic compounds had very remarkable contributions towards NLO technological applications. Further compounds (4-7) are utilized for the first time in electrochemical sensing of DNA, in vitro antioxidant and antiurease activity.
Collapse
Affiliation(s)
- Muhammad Rashid
- Institute of Chemical Sciences, Bahauddin Zakariya University Multan 60800 Pakistan +92-3006559811
| | - Muhammad Khalid
- Institute of Chemistry, Khwaja Fareed University of Engineering & Information Technology Rahim Yar Khan 64200 Pakistan
- Centre for Theoretical and Computational Research, Khwaja Fareed University of Engineering & Information Technology Rahim Yar Khan 64200 Pakistan
| | - Abida Ashraf
- Institute of Chemical Sciences, Bahauddin Zakariya University Multan 60800 Pakistan +92-3006559811
- Department of Chemistry, Govt. Graduate College Shah Rukne-Alam Multan Pakistan
| | - Tahira Saleem
- Institute of Chemical Sciences, Bahauddin Zakariya University Multan 60800 Pakistan +92-3006559811
| | - Iqra Shafiq
- Institute of Chemistry, Khwaja Fareed University of Engineering & Information Technology Rahim Yar Khan 64200 Pakistan
- Centre for Theoretical and Computational Research, Khwaja Fareed University of Engineering & Information Technology Rahim Yar Khan 64200 Pakistan
| | - Muhammad Azeem Shakil
- Institute of Chemical Sciences, Bahauddin Zakariya University Multan 60800 Pakistan +92-3006559811
| | - Briha Zainab
- Institute of Chemical Sciences, Bahauddin Zakariya University Multan 60800 Pakistan +92-3006559811
| | - Attalla F El-Kott
- Department of Biology, College of Science, King Khalid University Abha Saudi Arabia
- Department of Zoology, College of Science, Damanhour University Egypt
| | - Muhammad Yaqub
- Institute of Chemical Sciences, Bahauddin Zakariya University Multan 60800 Pakistan +92-3006559811
| | - Zahid Shafiq
- Institute of Chemical Sciences, Bahauddin Zakariya University Multan 60800 Pakistan +92-3006559811
| |
Collapse
|
14
|
Fitoz A, Yazan Z. Experimental and theoretical approaches to interactions between DNA and purine metabolism products. Int J Biol Macromol 2023; 248:125961. [PMID: 37487992 DOI: 10.1016/j.ijbiomac.2023.125961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/15/2023] [Revised: 06/13/2023] [Accepted: 07/12/2023] [Indexed: 07/26/2023]
Abstract
Deoxyribonucleic acid (DNA) is a significant target for small organic and inorganic drug molecules. Understanding the DNA interaction mechanism of these molecules is vital for new drug designs. In this work, interactions between xanthine (XT), theophylline (TP), and theobromine (TB) with calf-thymus double-strained DNA (dsDNA) were monitored via an experimental and theoretical approach. Experimentally, cyclic voltammetry (CV) and differential pulse voltammetry (DPV) techniques were used on the surface of the NiO/MWCNT/NNaM/PGE electrochemical platform in vitro. Kinetic parameters, including diffusion coefficients, surface concentrations, and standard heterogeneous rate constants, were measured in the absence and presence of DNA using scan rate studies. In the presence of DNA, kinetic parameters were observed to be reduced significantly. Thermodynamic parameters, such as DNA binding constants and standard free Gibbs energies, were calculated for each molecule using the CV and DPV techniques. Both techniques suggested a binding affinity order of XT > TB > TP. Theoretically, density functional theory was applied for geometry optimization, natural bond orbital analyses, and molecular orbital energies of XT, TP, and TB. Experimental and theoretical binding affinities confirm each other. The most energetically stable ligand-DNA complexes expressed that XT, TP, and TB interact with dsDNA via minor groove binding mode, using mostly hydrogen bonds.
Collapse
Affiliation(s)
- Alper Fitoz
- Ankara University, Faculty of Science, Department of Chemistry, 06560, Turkey
| | - Zehra Yazan
- Ankara University, Faculty of Science, Department of Chemistry, 06560, Turkey.
| |
Collapse
|
15
|
Li S, Zhang H, Zhu M, Kuang Z, Li X, Xu F, Miao S, Zhang Z, Lou X, Li H, Xia F. Electrochemical Biosensors for Whole Blood Analysis: Recent Progress, Challenges, and Future Perspectives. Chem Rev 2023. [PMID: 37262362 DOI: 10.1021/acs.chemrev.1c00759] [Citation(s) in RCA: 66] [Impact Index Per Article: 33.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/03/2023]
Abstract
Whole blood, as one of the most significant biological fluids, provides critical information for health management and disease monitoring. Over the past 10 years, advances in nanotechnology, microfluidics, and biomarker research have spurred the development of powerful miniaturized diagnostic systems for whole blood testing toward the goal of disease monitoring and treatment. Among the techniques employed for whole-blood diagnostics, electrochemical biosensors, as known to be rapid, sensitive, capable of miniaturization, reagentless and washing free, become a class of emerging technology to achieve the target detection specifically and directly in complex media, e.g., whole blood or even in the living body. Here we are aiming to provide a comprehensive review to summarize advances over the past decade in the development of electrochemical sensors for whole blood analysis. Further, we address the remaining challenges and opportunities to integrate electrochemical sensing platforms.
Collapse
Affiliation(s)
- Shaoguang Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Hongyuan Zhang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Man Zhu
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Zhujun Kuang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Xun Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Fan Xu
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Siyuan Miao
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Zishuo Zhang
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Xiaoding Lou
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Hui Li
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| | - Fan Xia
- State Key Laboratory of Biogeology and Environmental Geology, Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences, Wuhan 430074, China
| |
Collapse
|
16
|
Theyagarajan K, Kim YJ. Recent Developments in the Design and Fabrication of Electrochemical Biosensors Using Functional Materials and Molecules. BIOSENSORS 2023; 13:bios13040424. [PMID: 37185499 PMCID: PMC10135976 DOI: 10.3390/bios13040424] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/21/2023] [Revised: 03/21/2023] [Accepted: 03/24/2023] [Indexed: 05/17/2023]
Abstract
Electrochemical biosensors are superior technologies that are used to detect or sense biologically and environmentally significant analytes in a laboratory environment, or even in the form of portable handheld or wearable electronics. Recently, imprinted and implantable biosensors are emerging as point-of-care devices, which monitor the target analytes in a continuous environment and alert the intended users to anomalies. The stability and performance of the developed biosensor depend on the nature and properties of the electrode material or the platform on which the biosensor is constructed. Therefore, the biosensor platform plays an integral role in the effectiveness of the developed biosensor. Enormous effort has been dedicated to the rational design of the electrode material and to fabrication strategies for improving the performance of developed biosensors. Every year, in the search for multifarious electrode materials, thousands of new biosensor platforms are reported. Moreover, in order to construct an effectual biosensor, the researcher should familiarize themself with the sensible strategies behind electrode fabrication. Thus, we intend to shed light on various strategies and methodologies utilized in the design and fabrication of electrochemical biosensors that facilitate sensitive and selective detection of significant analytes. Furthermore, this review highlights the advantages of various electrode materials and the correlation between immobilized biomolecules and modified surfaces.
Collapse
Affiliation(s)
- K Theyagarajan
- Department of Electronic Engineering, Gachon University, Seongnam 13120, Republic of Korea
| | - Young-Joon Kim
- Department of Electronic Engineering, Gachon University, Seongnam 13120, Republic of Korea
| |
Collapse
|
17
|
Szymczyk A, Ziółkowski R, Malinowska E. Modern Electrochemical Biosensing Based on Nucleic Acids and Carbon Nanomaterials. SENSORS (BASEL, SWITZERLAND) 2023; 23:3230. [PMID: 36991941 PMCID: PMC10057701 DOI: 10.3390/s23063230] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/10/2023] [Accepted: 03/16/2023] [Indexed: 06/19/2023]
Abstract
To meet the requirements of novel therapies, effective treatments should be supported by diagnostic tools characterized by appropriate analytical and working parameters. These are, in particular, fast and reliable responses that are proportional to analyte concentration, with low detection limits, high selectivity, cost-efficient construction, and portability, allowing for the development of point-of-care devices. Biosensors using nucleic acids as receptors has turned out to be an effective approach for meeting the abovementioned requirements. Careful design of the receptor layers will allow them to obtain DNA biosensors that are dedicated to almost any analyte, including ions, low and high molecular weight compounds, nucleic acids, proteins, and even whole cells. The impulse for the application of carbon nanomaterials in electrochemical DNA biosensors is rooted in the possibility to further influence their analytical parameters and adjust them to the chosen analysis. Such nanomaterials enable the lowering of the detection limit, the extension of the biosensor linear response, or the increase in selectivity. This is possible thanks to their high conductivity, large surface-to-area ratio, ease of chemical modification, and introduction of other nanomaterials, such as nanoparticles, into the carbon structures. This review discusses the recent advances on the design and application of carbon nanomaterials in electrochemical DNA biosensors that are dedicated especially to modern medical diagnostics.
Collapse
Affiliation(s)
- Anna Szymczyk
- Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Stanisława Noakowskiego 3, 00-664 Warsaw, Poland
- Doctoral School, Warsaw University of Technology, Plac Politechniki 1, 00-661 Warsaw, Poland
| | - Robert Ziółkowski
- Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Stanisława Noakowskiego 3, 00-664 Warsaw, Poland
| | - Elżbieta Malinowska
- Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Stanisława Noakowskiego 3, 00-664 Warsaw, Poland
- Center for Advanced Materials and Technologies, Warsaw University of Technology, Poleczki 19, 02-822 Warsaw, Poland
| |
Collapse
|
18
|
Barati F, Avatefi M, Moghadam NB, Asghari S, Ekrami E, Mahmoudifard M. A review of graphene quantum dots and their potential biomedical applications. J Biomater Appl 2023; 37:1137-1158. [PMID: 36066191 DOI: 10.1177/08853282221125311] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
Abstract
Today, nanobiotechnology is a pioneering technology in biomedicine. Every day, new nanomaterials are synthesized with elevated physiochemical properties for better diagnosis and treatment of diseases. One advancing class of materials is the Graphene family. Among different kinds of graphene derivatives, graphene quantum dots (GQDs) show fantastic optical, electrical, and electrochemical features originating from their unique quantum confinement effect. Due to the distinct properties of GQD, including large surface-to-volume ratio, low cytotoxicity, and easy functionalization, this nanomaterial has gone popular in biomedical field. Herein, a short overview of different strategies developed for GQD synthesis and functionalization is discussed. In the following, the most recent progress of GQD based nanomaterials in different biomedical fields, including bio-imaging, drug/gene delivery, antimicrobial, tissue engineering, and biosensors, are reviewed.
Collapse
Affiliation(s)
- Fatemeh Barati
- Department of Industrial and Environmental Biotechnology, 48482National Institute for Genetic Engineering and Biotechnology, Tehran, Iran
| | - Manizheh Avatefi
- Department of Industrial and Environmental Biotechnology, 48482National Institute for Genetic Engineering and Biotechnology, Tehran, Iran
| | - Negin Borzooee Moghadam
- Department of Industrial and Environmental Biotechnology, 48482National Institute for Genetic Engineering and Biotechnology, Tehran, Iran
| | - Sahar Asghari
- Department of Industrial and Environmental Biotechnology, 48482National Institute for Genetic Engineering and Biotechnology, Tehran, Iran
| | - Elena Ekrami
- Department of Industrial and Environmental Biotechnology, 48482National Institute for Genetic Engineering and Biotechnology, Tehran, Iran
| | - Matin Mahmoudifard
- Department of Industrial and Environmental Biotechnology, 48482National Institute for Genetic Engineering and Biotechnology, Tehran, Iran
| |
Collapse
|
19
|
Karami-Kolmoti P, Beitollahi H, Modiri S. Voltammetric detection of catechol in real samples using MnO2 nanorods-graphene oxide nanocomposite modified electrode. JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION 2022. [DOI: 10.1007/s11694-022-01692-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
20
|
A composite adsorbent of graphene quantum dots, mesoporous carbon, and molecularly imprinted polymer to extract nonsteroidal anti-inflammatory drugs in milk. Mikrochim Acta 2022; 189:446. [DOI: 10.1007/s00604-022-05550-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/13/2022] [Accepted: 10/25/2022] [Indexed: 11/13/2022]
|
21
|
Beitollahi H, Tajik S, Dourandish Z, Garkani Nejad F. Simple Preparation and Characterization of Hierarchical Flower-like NiCo 2O 4 Nanoplates: Applications for Sunset Yellow Electrochemical Analysis. BIOSENSORS 2022; 12:bios12110912. [PMID: 36354421 PMCID: PMC9688067 DOI: 10.3390/bios12110912] [Citation(s) in RCA: 13] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/08/2022] [Revised: 10/07/2022] [Accepted: 10/14/2022] [Indexed: 06/12/2023]
Abstract
The current work was performed to construct a novel electrochemical sensing system for determination of sunset yellow via the modification of screen-printed graphite electrode modified with hierarchical flower-like NiCo2O4 nanoplates (NiCo2O4/SPGE). The prepared material (hierarchical flower-like NiCo2O4 nanoplates) was analyzed by diverse microscopic and spectroscopic approaches for the crystallinity, composition, and morphology. Chronoamperometry, differential pulse voltammetry, linear sweep voltammetry, and cyclic voltammetry were used for determination of the electrochemical behavior of sunset yellow. The as-fabricated sensor had appreciable electro-catalytic performance and current sensitivity in detecting the sunset yellow. There were some advantages for NiCo2O4/SPGE under the optimized circumstances of sunset yellow determination, including a broad dynamic linear between 0.02 and 145.0 µM, high sensitivity of 0.67 μA/(μM.cm2), and a narrow limit of detection of 0.008 μM. The practical applicability of the proposed sensor was verified by determining the sunset yellow in real matrices, with satisfactory recoveries.
Collapse
Affiliation(s)
- Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman P.O. Box 76318-85356, Iran
| | - Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman P.O. Box 76169-13555, Iran
| | - Zahra Dourandish
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman P.O. Box 76318-85356, Iran
| | - Fariba Garkani Nejad
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman P.O. Box 76318-85356, Iran
| |
Collapse
|
22
|
Safitri E, Heng LY, Ahmad M, Tan LL, Nazaruddin N, Suhud K, Chiang CP, Iqhrammullah M. Electrochemical DNA Biosensor Based on Mercaptopropionic Acid-Capped ZnS Quantum Dots for Determination of the Gender of Arowana Fish. BIOSENSORS 2022; 12:bios12080650. [PMID: 36005045 PMCID: PMC9405751 DOI: 10.3390/bios12080650] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/08/2022] [Revised: 08/10/2022] [Accepted: 08/10/2022] [Indexed: 11/16/2022]
Abstract
A new electrochemical DNA biosensor based on mercaptopropionic acid (MPA)-capped ZnS quantum dots (MPA-ZnS QDs) immobilization matrix for covalent binding with 20-base aminated oligonucleotide has been successfully developed. Prior to the modification, screen-printed carbon paste electrode (SPE) was self-assembled with multilayer gold nanoparticles (AuNPs) and cysteamine (Cys). The inclusion of MPA-ZnS QDs semiconducting material in modified electrodes has enhanced the electron transfer between the SPE transducer and DNA leading to improved bioanalytical assay of target biomolecules. Electrochemical studies performed by cyclic voltammetry (CV) and differential pulsed voltammetry (DPV) demonstrated that the MPA-ZnS QDs modified AuNPs electrode was able to produce a lower charge transfer resistance response and hence higher electrical current response. Under optimal conditions, the immobilized synthetic DNA probe exhibited high selectivity towards synthetic target DNA. Based on the DPV response of the reduction of anthraquinone monosulphonic acid (AQMS) redox probe, the MPA-ZnS QDs-based electrochemical DNA biosensor responded to target DNA concentration from 1 × 10−9 μM to 1 × 10−3 μM with a sensitivity 1.2884 ± 0.12 µA, linear correlation coefficient (R2) of 0.9848 and limit of detection (LOD) of 1 × 10−11 μM target DNA. The DNA biosensor exhibited satisfactory reproducibility with an average relative standard deviation (RSD) of 7.4%. The proposed electrochemical transducer substrate has been employed to immobilize the aminated Arowana fish (Scleropages formosus) DNA probe. The DNA biosensor showed linearity to target DNA from 1 × 10−11 to 1 × 10−6 µM (R2 = 0.9785) with sensitivity 1.1251 ± 0.243 µA and LOD of 1 × 10−11 µM. The biosensor has been successfully used to determine the gender of Arowana fish without incorporating toxic raw materials previously employed in the hazardous processing conditions of polypyrrole chemical conducting polymer, whereby the cleaning step becomes difficult with thicker films due to high levels of toxic residues from the decrease in polymerization efficacy as films grew.
Collapse
Affiliation(s)
- Eka Safitri
- Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Syiah Kuala, Darussalam, Banda Aceh 23111, Indonesia
- Correspondence:
| | - Lee Yook Heng
- Department of Chemical Sciences, Faculty of Science and Technology, Universiti Kebangsaan Malaysia, Bangi 43600, Selangor Darul Ehsan, Malaysia
- Southeast Asia Disaster Prevention Research Initiative (SEADPRI-UKM), Institute for Environment and Development (LESTARI), Universiti Kebangsaan Malaysia, Bangi 43600, Selangor Darul Ehsan, Malaysia
| | - Musa Ahmad
- Chemical Technology Program, Faculty of Science and Technology, University Sains Islam Malaysia (USIM), Nilai 91800, Negeri Sembilan, Malaysia
| | - Ling Ling Tan
- Southeast Asia Disaster Prevention Research Initiative (SEADPRI-UKM), Institute for Environment and Development (LESTARI), Universiti Kebangsaan Malaysia, Bangi 43600, Selangor Darul Ehsan, Malaysia
| | - Nazaruddin Nazaruddin
- Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Syiah Kuala, Darussalam, Banda Aceh 23111, Indonesia
| | - Khairi Suhud
- Department of Chemistry, Faculty of Mathematics and Natural Sciences, Universitas Syiah Kuala, Darussalam, Banda Aceh 23111, Indonesia
| | - Chew Poh Chiang
- Freshwater Fisheries Research Division, Fisheries Research Institute Glami Lemi, Jelebu 71650, Negeri Sembilan, Malaysia
| | - Muhammad Iqhrammullah
- Department of Life Sciences and Chemistry, Jacobs University Bremen, 28759 Bremen, Germany
| |
Collapse
|
23
|
Nimal R, Nur Unal D, Erkmen C, Bozal-Palabiyik B, Siddiq M, Eren G, Shah A, Uslu B. Development of the electrochemical, spectroscopic and molecular docking approaches toward the investigation of interaction between DNA and anti-leukemic drug azacytidine. Bioelectrochemistry 2022; 146:108135. [DOI: 10.1016/j.bioelechem.2022.108135] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/24/2021] [Revised: 04/12/2022] [Accepted: 04/14/2022] [Indexed: 12/16/2022]
|
24
|
Wang H, Chen R, Zhang F, Yu Z, Wang Y, Tang Z, Yang L, Tang X, Xiong B. Superhydrophobic Paper-Based Microfluidic Field-Effect Transistor Biosensor Functionalized with Semiconducting Single-Walled Carbon Nanotube and DNAzyme for Hypocalcemia Diagnosis. Int J Mol Sci 2022; 23:ijms23147799. [PMID: 35887147 PMCID: PMC9318675 DOI: 10.3390/ijms23147799] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2022] [Revised: 07/05/2022] [Accepted: 07/07/2022] [Indexed: 02/06/2023] Open
Abstract
Hypocalcemia is caused by a sharp decline in blood calcium concentration after dairy cow calving, which can lead to various diseases or even death. It is necessary to develop an inexpensive, easy-to-operate, reliable sensor to diagnose hypocalcemia. The cellulose-paper-based microfluidic field-effect biosensor is promising for point-of-care, but it has poor mechanical strength and a short service life after exposure to an aqueous solution. Octadecyltrichlorosilane (OTS), as a popular organosilane derivative, can improve the hydrophobicity of cellulose paper to overcome the shortage of cellulose paper. In this work, OTS was used to produce the superhydrophobic cellulose paper that enhances the mechanical strength and short service life of MFB, and a microfluidic field-effect biosensor (MFB) with semiconducting single-walled carbon nanotubes (SWNTs) and DNAzyme was then developed for the Ca2+ determination. Pyrene carboxylic acid (PCA) attached to SWNTs through a non-covalent π-π stacking interaction provided a carboxyl group that can bond with an amino group of DNAzyme. Two DNAzymes with different sensitivities were designed by changing the sequence length and cleavage site, which were functionalized with SPFET/SWNTs-PCA to form Dual-MFB, decreasing the interference of impurities in cow blood. After optimizing the detecting parameters, Dual-MFB could determine the Ca2+ concentration in the range of 25 μM to 5 mM, with a detection limit of 10.7 μM. The proposed Dual-MFB was applied to measure Ca2+ concentration in cow blood, which provided a new method to diagnose hypocalcemia after dairy cow calving.
Collapse
Affiliation(s)
- Hui Wang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
| | - Ruipeng Chen
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
| | - Fan Zhang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
- State Key Laboratory of Animal Nutrition, College of Animal Science and Technology, China Agricultural University, Beijing 100193, China
| | - Zhixue Yu
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
| | - Yue Wang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
| | - Zhonglin Tang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
| | - Liang Yang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
| | - Xiangfang Tang
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
- Correspondence: (X.T.); (B.X.)
| | - Benhai Xiong
- State Key Laboratory of Animal Nutrition, Institute of Animal Science, Chinese Academy of Agricultural Sciences, Beijing 100193, China; (H.W.); (R.C.); (F.Z.); (Z.Y.); (Y.W.); (Z.T.); (L.Y.)
- Correspondence: (X.T.); (B.X.)
| |
Collapse
|
25
|
Jahani PM, Beitollahi H, Tajik S. Surface amplification of graphite screen printed electrode using reduced graphene oxide/polypyrrole nanotubes nanocomposite; a powerful electrochemical strategy for determination of sulfite in food samples. Food Chem Toxicol 2022; 167:113274. [PMID: 35843424 DOI: 10.1016/j.fct.2022.113274] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2022] [Revised: 06/20/2022] [Accepted: 07/02/2022] [Indexed: 10/17/2022]
Abstract
The present research presents synthesis and substantial utilization of a nanocomposite of reduced graphene oxide/polypyrrole nanotubes to modify graphite screen printed electrode (rGO/PPy NTs-GSPE) for detection of sulfite. The nanocomposite preparation was done by hydrothermal protocol, followed by characterization by energy-dispersive X-ray (EDX) and field emission-scanning electron microscopy (FE-SEM). Electrocatalytic sensing of sulfite is carried out using differential pulse voltammetric (DPV), linear sweep voltammetry (LSV), cyclic voltammetric (CV), and Chronoamperometry. Electrochemical behaviors of modified and unmodified electrodes were explored with CV method. In addition, DPV was employed for anodic peak and quantitatively detecting sulfite. The DPV results unveiled a linear response of the sensor to various sulfite contents (0.04-565.0 μM) with a narrow detection limit (0.01 μM) and admirable sensitivity (0.0483 μA/μΜ). The diffusion coefficient (D) for sulfite using rGO/PPy NTs-GSPE, 9.9 × 10-6 cm 2/s was obtained. The sensor was also successful in the sulfite detection in real specimens.
Collapse
Affiliation(s)
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran
| | - Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman, Iran.
| |
Collapse
|
26
|
Graphene quantum dots: synthesis, properties, and applications to the development of optical and electrochemical sensors for chemical sensing. Mikrochim Acta 2022; 189:258. [PMID: 35701638 DOI: 10.1007/s00604-022-05353-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 05/24/2022] [Indexed: 10/18/2022]
Abstract
GQDs exhibits exceptional electrochemical activity owing to their active edge sites that make them very attractive for biosensing applications. However, their use in the design of new biosensing devices for application to the detection and quantification of toxins, pathogens, and clinical biomarkers has so far not investigated in detail. In this regard, herein we provide a detailed review on various methodologies employed for the synthesis of GQDs, including bottom-up and top-down approaches, with a special focus on their applications in biosensing via fluorescence, photoluminescence, chemiluminescence, electrochemiluminescence, fluorescence resonance energy transfer, and electrochemical techniques. We believe that this review will shed light on the critical issues and widen the applications of GQDs for the design of biosensors with improved analytical response for future applications. HIGHLIGHTS: • Properties of GQDs play a critical role in biosensing applications. • Synthesis of GQDs using top-down and bottom-up approaches is discussed comprehensively. • Overview of advancements in GQD-based sensors over the last decade. • Methods for the design of selective and sensitive GQD-based sensors. • Challenges and opportunities for future GQD-based sensors.
Collapse
|
27
|
The simulation of a green room-temperature ternary solution of water, methanol and 1-ethyl-3-methyl imidazolium chloride by all-atom Monte Carlo and DFT computational approaches. J Mol Liq 2022. [DOI: 10.1016/j.molliq.2022.118903] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
28
|
Parisa Baghbanpoor, Shishehbore MR, Beitollahi H, Sheibani A. The Application of Ferrocene Derivative and CeO–ZnO Nanocomposite-Modified Carbon Paste Electrode for Simultaneous Detection of Penicillamine and Tryptophan. RUSS J ELECTROCHEM+ 2022. [DOI: 10.1134/s1023193522040048] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
29
|
Karimi-Maleh H, Beitollahi H, Senthil Kumar P, Tajik S, Jahani PM, Karimi F, Karaman C, Vasseghian Y, Baghayeri M, Rouhi J, Show PL, Rajendran S, Fu L, Zare N. Recent advances in carbon nanomaterials-based electrochemical sensors for food azo dyes detection. Food Chem Toxicol 2022; 164:112961. [PMID: 35395340 DOI: 10.1016/j.fct.2022.112961] [Citation(s) in RCA: 160] [Impact Index Per Article: 53.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 03/17/2022] [Accepted: 03/22/2022] [Indexed: 01/24/2023]
Abstract
Azo dyes as widely applied food colorants are popular for their stability and affordability. On the other hand, many of these dyes can have harmful impacts on living organs, which underscores the need to control the content of this group of dyes in food. Among the various analytical approaches for detecting the azo dyes, special attention has been paid to electro-analytical techniques for reasons such as admirable sensitivity, excellent selectivity, reproducibility, miniaturization, green nature, low cost, less time to prepare and detect of specimens and the ability to modify the electrode. Satisfactory results have been obtained so far for carbon-based nanomaterials in the fabrication of electrochemical sensing systems in detecting the levels of these materials in various specimens. The purpose of this review article is to investigate carbon nanomaterial-supported techniques for electrochemical sensing systems on the analysis of azo dyes in food samples in terms of carbon nanomaterials used, like carbon nanotubes (CNT) and grapheme (Gr).
Collapse
Affiliation(s)
- Hassan Karimi-Maleh
- School of Resources and Environment, University of Electronic Science and Technology of China, P.O. Box 611731, Xiyuan Ave, Chengdu, PR China; Department of Chemical Engineering, Quchan University of Technology, Quchan, 9477177870, Iran.
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology, Kerman, Iran.
| | - P Senthil Kumar
- Department of Chemical Engineering, Sri Sivasubramaniya Nadar College of Engineering, Kalavakkam, Chennai, 603110, India.
| | - Somayeh Tajik
- Research Center of Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman, Iran
| | | | - Fatemeh Karimi
- Department of Chemical Engineering, Quchan University of Technology, Quchan, 9477177870, Iran.
| | - Ceren Karaman
- Department of Electricity and Energy, Akdeniz University, Antalya, 07070, Turkey
| | - Yasser Vasseghian
- Department of Chemistry, Soongsil University, Seoul, 06978, South Korea
| | - Mehdi Baghayeri
- Department of Chemistry, Faculty of Science, Hakim Sabzevari University, P.O. Box 397, Sabzevar, Iran
| | - Jalal Rouhi
- Faculty of Physics, University of Tabriz, Tabriz, 51566, Iran
| | - Pau-Loke Show
- Department of Chemical and Environmental Engineering, Faculty of Science and Engineering, University of Nottingham Malaysia, Jalan Broga, Semenyih, 43500, Selangor Darul Ehsan, Malaysia
| | - Saravanan Rajendran
- Faculty of Engineering, Department of Mechanical Engineering, University of Tarapaca, 1775, Arica, Chile
| | - Li Fu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou, 310018, PR China
| | - Najmeh Zare
- Department of Chemical Engineering, Quchan University of Technology, Quchan, 9477177870, Iran
| |
Collapse
|
30
|
Zoheira Bagheri Nasab, Fariba Garkani Nejad. Electrochemical Sensor Based on a Modified Graphite Screen Printed Electrode for Amitriptyline Determination. SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY 2022. [DOI: 10.3103/s1068375522010070] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
31
|
Mousazadeh F, Mohammadi SZ, Akbari S, Mofidinasab N, Aflatoonian MR, Shokooh-Saljooghi A. Recent Advantages of Mediator Based Chemically Modified Electrodes;
Powerful Approach in Electroanalytical Chemistry. CURR ANAL CHEM 2022. [DOI: 10.2174/1573411017999201224124347] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Modified electrodes have advanced from the initial studies aimed at understanding
electron transfer in films to applications in areas such as energy production and analytical
chemistry. This review emphasizes the major classes of modified electrodes with mediators
that are being explored for improving analytical methodology. Chemically modified electrodes
(CMEs) have been widely used to counter the problems of poor sensitivity and selectivity faced in
bare electrodes. We have briefly reviewed the organometallic and organic mediators that have been
extensively employed to engineer adapted electrode surfaces for the detection of different compounds.
Also, the characteristics of the materials that improve the electrocatalytic activity of the
modified surfaces are discussed.
Objective:
Improvement and promotion of pragmatic CMEs have generated a diversity of novel
and probable strong detection prospects for electroanalysis. While the capability of handling the
chemical nature of the electrode/solution interface accurately and creatively increases , it is predictable
that different mediators-based CMEs could be developed with electrocatalytic activity and
completely new applications be advanced.
Collapse
Affiliation(s)
| | | | - Sedighe Akbari
- Islamic Azad University, Shahrbabak Branch, Shahrbabak,Iran
| | | | - Mohammad Reza Aflatoonian
- Research Center for Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman,Iran
| | | |
Collapse
|
32
|
Shahraki S, Masrournia M, Karimi-Maleh H. Fabrication of Electrochemical Sensor for Epinine Determination
Amplified with MgO/CNTs Nanocomposite and Ionic Liquid. CURR ANAL CHEM 2022. [DOI: 10.2174/1573411017666210303091301] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
Abstract
Background:
Catecholamines are a large group of pharmacological and biological compounds
that are widely used in biological systems. These compounds are prepared both naturally
and synthetically with many key roles in the human body and its activities. Therefore, many researchers
focused on the identification and determination of catecholamines in biological samples.
Methods:
MgO/SWCNTs were synthesized through the chemical precipitation method. In addition,
cyclic voltammetry, differential pulse voltammetry, and chronoamperometric methods were used
for the electro-oxidation reaction study of epinine at the surface of the modified electrode.
Results:
Carbon paste electrode (CPE) modified with MgO/SWCNTs nanocomposite and 1-butyl-
3-methylimidazolium methanesulfonate (BMMS) was used as an electrochemical sensor for the
determination of epinine. The results showed a linear dynamic range of 5.0 nM-250 μM with a
detection limit of 0.1 nM for epinine determination using MgO/SWCNTs/BMMS/CPE as a sensor.
Conclusion:
In the present study, a highly sensitive electrochemical sensor was designed and fabricated
as an analytical tool for the determination of epinine. MgO/SWCNTs/BMMS/CPE was
successfully used for the determination of epinine in water and dextrose saline with an acceptable
recovery range of 98.7%-102.72%.
Collapse
Affiliation(s)
- Shirin Shahraki
- Department of Chemistry, Mashhad Branch, Islamic Azad University, Mashhad,Iran
| | | | - Hassan Karimi-Maleh
- Department of Chemical Engineering, Laboratory of Nanotechnology, Quchan University of Advanced Technology, Quchan,Iran
| |
Collapse
|
33
|
Fariba Beigmoradi, Hadi Beitollahi. MXene/La3+ Doped ZnO/Hb Nanocomposite Modified Glassy Carbon Electrode as Novel Voltammetric Sensor for Determination of Hydrogen Peroxide. SURFACE ENGINEERING AND APPLIED ELECTROCHEMISTRY 2021. [DOI: 10.3103/s106837552106003x] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
34
|
Imanzadeh H, Bakirhan NK, Kuralay F, Amiri M, Ozkan SA. Achievements of Graphene and Its Derivatives Materials on Electrochemical Drug Assays and Drug-DNA Interactions. Crit Rev Anal Chem 2021; 53:1263-1284. [PMID: 34941476 DOI: 10.1080/10408347.2021.2018568] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 08/24/2023]
Abstract
Graphene, emerging as a true two-dimensional (2D) material, has attracted increasing attention due to its unique physical and electrochemical properties such as high surface area, excellent conductivity, high mechanical strength, and ease of functionalization and mass production. The entire scientific community recognizes the significance and potential impact of graphene. Electrochemical detection strategies have advantages such as being simple, fast, and low-cost. The use of graphene as an excellent interface for electrode modification provides a promising way to construct more sensitive and stable electrochemical (bio)sensors. The review presents sensors based on graphene and its derivatives for electrochemical drug assays from pharmaceutical dosage forms and biological samples. Future perspectives in this rapidly developing field are also discussed. In addition, the interaction of several important anticancer drug molecules with deoxyribonucleic acid (DNA) that was immobilized onto graphene-modified electrodes has been detailed in terms of dosage regulation and utility purposes.
Collapse
Affiliation(s)
- Hamideh Imanzadeh
- Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, Iran
- Faculty of Pharmacy, Department of Analytical Chemistry, Ankara University, Ankara, Turkey
| | - Nurgul K Bakirhan
- Department of Analytical Chemistry, Gulhane Faculty of Pharmacy, University of Health Sciences, Ankara, Turkey
| | - Filiz Kuralay
- Department of Chemistry, Faculty of Science, Hacettepe University, Ankara, Turkey
| | - Mandana Amiri
- Department of Chemistry, University of Mohaghegh Ardabili, Ardabil, Iran
| | - Sibel A Ozkan
- Faculty of Pharmacy, Department of Analytical Chemistry, Ankara University, Ankara, Turkey
| |
Collapse
|
35
|
Simple fabrication of a hexagonal prisms with hexagonal pyramid tips V2O5@MOF(V, Co) and its application as electrochemical sensor for Pb2+. INORG CHEM COMMUN 2021. [DOI: 10.1016/j.inoche.2021.108966] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
|
36
|
Tarahomi S, Rounaghi GH, Daneshvar L, Eftekhari M. A Carbon Ionic Liquid Paste Sensor Modified with Lanthanum Nanorods /MWCNTs/Nafion Hybrid Composite for Carbamazepine Screening in Biological and Pharmaceutical Media. ChemistrySelect 2021. [DOI: 10.1002/slct.202102600] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2023]
Affiliation(s)
- Somayeh Tarahomi
- Department of Chemistry Faculty of Sciences Ferdowsi University of Mashhad Mashhad Iran
| | | | - Leili Daneshvar
- Department of Chemistry Faculty of Sciences Ferdowsi University of Mashhad Mashhad Iran
| | - Mohammad Eftekhari
- Department of Chemistry Faculty of Sciences Ferdowsi University of Mashhad Mashhad Iran
| |
Collapse
|
37
|
Elshafey R, Abo-Sobehy GF, Radi AE. Graphene oxide/graphene quantum dots: A platform for probing ds-DNA-dimethoate interaction and dimethoate sensing. J Electroanal Chem (Lausanne) 2021. [DOI: 10.1016/j.jelechem.2021.115678] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/20/2022]
|
38
|
Graphene Quantum Dots-Based Nanocomposites Applied in Electrochemical Sensors: A Recent Survey. ELECTROCHEM 2021. [DOI: 10.3390/electrochem2030032] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Graphene quantum dots (GQDs) have been widely investigated in recent years due to their outstanding physicochemical properties. Their remarkable characteristics allied to their capability of being easily synthesized and combined with other materials have allowed their use as electrochemical sensing platforms. In this work, we survey recent applications of GQDs-based nanocomposites in electrochemical sensors and biosensors. Firstly, the main characteristics and synthesis methods of GQDs are addressed. Next, the strategies generally used to obtain the GQDs nanocomposites are discussed. Emphasis is given on the applications of GQDs combined with distinct 0D, 1D, 2D nanomaterials, metal-organic frameworks (MOFs), molecularly imprinted polymers (MIPs), ionic liquids, as well as other types of materials, in varied electrochemical sensors and biosensors for detecting analytes of environmental, medical, and agricultural interest. We also discuss the current trends and challenges towards real applications of GQDs in electrochemical sensors.
Collapse
|
39
|
Mehmandoust M, Erk N, Alizadeh M, Salmanpour S. Voltammetric carbon nanotubes based sensor for determination of tryptophan in the milk sample. JOURNAL OF FOOD MEASUREMENT AND CHARACTERIZATION 2021. [DOI: 10.1007/s11694-021-01100-8] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
|
40
|
Hassani Moghadam F, Taher MA, Karimi-Maleh H. Doxorubicin Anticancer Drug Monitoring by ds-DNA-Based Electrochemical Biosensor in Clinical Samples. MICROMACHINES 2021; 12:808. [PMID: 34357218 PMCID: PMC8306963 DOI: 10.3390/mi12070808] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/09/2021] [Revised: 07/06/2021] [Accepted: 07/07/2021] [Indexed: 12/28/2022]
Abstract
In this research, glassy carbon electrode (GCE) amplified with single-wall carbon nanotubes (SWCNTs) and ds-DNA was fabricated and utilized for voltammetric sensing of doxorubicin with a low detection limit. In this technique, the reduction in guanine signal of ds-DNA in the presence of doxorubicin (DOX) was chosen as an analytical factor. The molecular docking study revealed that the doxorubicin drug interacted with DNA through intercalation mode, which was in agreement with obtained experimental results. The DOX detection performance of ds-DNA/SWCNTs/GCE was assessed at a concentration range of 1.0 nM-20.0 µM. The detection limit was found to be 0.6 nM that was comparable and even better (in many cases) than that of previous electrochemical reported sensors. In the final step, the ds-DNA/SWCNTs/GCE showed powerful ability for determination of the DOX in injection samples with acceptable recovery data.
Collapse
Affiliation(s)
| | - Mohammad A. Taher
- Department of Chemistry, Shahid Bahonar University of Kerman, Kerman 7616913439, Iran;
| | - Hassan Karimi-Maleh
- Laboratory of Nanotechnology, Department of Chemical Engineering and Energy, Quchan University of Technology, Quchan 9477177870, Iran
| |
Collapse
|
41
|
Hybrid nanostructures of Pd-WO 3 grown on graphitic carbon nitride for trace level electrochemical detection of paraoxon-ethyl. Mikrochim Acta 2021; 188:233. [PMID: 34145512 DOI: 10.1007/s00604-021-04866-2] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/17/2021] [Accepted: 05/13/2021] [Indexed: 01/29/2023]
Abstract
Well-defined crystal structures of Pd-doped WO3 nanorods were assembled on graphitic carbon sheets (Pd-WO3/g-C3N4) for ultrasensitive detection of paraoxon-ethyl (PEL) using an electrochemical method. The electrochemical behavior of PEL on the Pd-WO3/g-C3N4 hybrid composite was investigated using cyclic voltammetry (CV) and amperometric techniques. The Pd-WO3 crystallite was seen to modify the kinetics of g-C3N4, which improved the reduction/redox peak currents of PEL at the Pd-WO3/g-C3N4 composite compared to those of the g-C3N4 and WO3/g-C3N4-modified electrode. Moreover, the π-π interaction and hydrogen bond between the PEL and Pd-WO3/g-C3N4 composite improved the charge-transfer properties. The Pd-WO3/g-C3N4 hybrid composite was therefore able to obtain an enhanced sensitivity (3.70 ± 0.05 μA μM-1 cm-2) and low detection limit (0.03 nM; S/N = 3) with a wide range of linear concentrations (0.01-60 and 80-900.0 ± 5 μM) at applied potential of - 0.63 V (vs. Ag/AgCl). The detection of PEL in agricultural water and soil samples was successfully demonstrated with satisfactory RSD of 2.5 to 3.1% and recovery results of 97 to 102%, respectively.
Collapse
|
42
|
Au@SnO 2-vertical graphene-based microneedle sensor for in-situ determination of abscisic acid in plants. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 127:112237. [PMID: 34225877 DOI: 10.1016/j.msec.2021.112237] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2021] [Revised: 04/26/2021] [Accepted: 06/01/2021] [Indexed: 11/22/2022]
Abstract
For developing electrochemical plant sensors, in-situ detection of hormone levels in living plants is worth attempting. A microneedle array sensor based on Au@SnO2-vertical graphene (VG)/Ta microelectrodes was constructed for analyzing abscisic acid (ABA) in plants. Graphene was vertically grown on Ta wires with a diameter of 0.6 mm by direct current arc plasma jet chemical vapor deposition with SnO2 as the Au catalyst carrier. These VG nanosheets were embedded with core-shell Au@SnO2 nanoparticles, and the formation mechanism of the sensing layer was investigated. Three Au@SnO2-VG microelectrodes, one Ti wire, and one Pt wire were packed into a microneedle array sensor with a three-electrode system. ABA was then quantitatively detected by direct electrocatalytic oxidation, which involves the synergistic catalytic effects of the abundant catalytic active sites of the Au@SnO2 nanoparticles and the excellent conductivity of the VG nanosheets. The microneedle array sensor responds to ABA in the pH range 4-7, the response concentration range was 0.012 (or 0.024)-495.2 μM, and the detection limit varied between 0.002 and 0.005 μM. The small size, wide pH range, low detection limit, and wide linear concentration range allow the microneedle array sensor to be inserted into plants for in-situ detection of ABA.
Collapse
|
43
|
Karimi-Maleh H, Yola ML, Atar N, Orooji Y, Karimi F, Senthil Kumar P, Rouhi J, Baghayeri M. A novel detection method for organophosphorus insecticide fenamiphos: Molecularly imprinted electrochemical sensor based on core-shell Co3O4@MOF-74 nanocomposite. J Colloid Interface Sci 2021; 592:174-185. [DOI: 10.1016/j.jcis.2021.02.066] [Citation(s) in RCA: 198] [Impact Index Per Article: 49.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/06/2021] [Revised: 02/14/2021] [Accepted: 02/15/2021] [Indexed: 01/28/2023]
|
44
|
Moghaddam A, Zamani HA, Karimi-Maleh H. A New Electrochemical Platform for Dasatinib Anticancer Drug Sensing Using Fe 3O 4-SWCNTs/Ionic Liquid Paste Sensor. MICROMACHINES 2021; 12:mi12040437. [PMID: 33919951 PMCID: PMC8070955 DOI: 10.3390/mi12040437] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/03/2021] [Revised: 04/06/2021] [Accepted: 04/12/2021] [Indexed: 02/06/2023]
Abstract
A new electrochemical platform was suggested for the sensing of the dasatinib (DA) anticancer drug based on paste electrode modification (PE) amplified with Fe3O4-SWCNTs nanocomposite and 1-hexyl-3-methylimidazolium tetrafluoroborate (mim-BF4−). The new platform showed a linear dynamic range from 0.001–220 µM with a detection limit of 0.7 nM to determine DA at optimal condition. Electrochemical investigation showed that the redox reaction of DA is relative to changing the pH of solution. Moreover, Fe3O4-SWCNTs/mim-BF4−/PE has improved the oxidation current of DA about 5.58 times which reduced its oxidation potential by about 120 mV at optimal condition. In the final step, Fe3O4-SWCNTs/mim-BF4−/PE was used as an analytical platform to determine the DA in tablets and a dextrose saline spike sample, and the results showed recovery data 99.58–103.6% which confirm the powerful ability of the sensor as an analytical tool to determine the DA in real samples.
Collapse
Affiliation(s)
- Ali Moghaddam
- Department of Applied Chemistry, Mashhad Branch, Islamic Azad University, Mashhad 9187147578, Iran;
| | - Hassan Ali Zamani
- Department of Applied Chemistry, Mashhad Branch, Islamic Azad University, Mashhad 9187147578, Iran;
- Correspondence: (H.A.Z.); (H.K.-M.); Tel.: +98-9112540112 (H.K.-M.)
| | - Hassan Karimi-Maleh
- Laboratory of Nanotechnology, Department of Chemical Engineering and Energy, Quchan University of Technology, Quchan 9477177870, Iran
- Correspondence: (H.A.Z.); (H.K.-M.); Tel.: +98-9112540112 (H.K.-M.)
| |
Collapse
|
45
|
Polymerized carbon nanotube paste electrode as a sensing material for the detection of adrenaline with folic acid. MONATSHEFTE FUR CHEMIE 2021. [DOI: 10.1007/s00706-021-02756-0] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
|
46
|
Tajik S, Beitollahi H, Hosseinzadeh R, Aghaei Afshar A, Varma RS, Jang HW, Shokouhimehr M. Electrochemical Detection of Hydrazine by Carbon Paste Electrode Modified with Ferrocene Derivatives, Ionic Liquid, and CoS 2-Carbon Nanotube Nanocomposite. ACS OMEGA 2021; 6:4641-4648. [PMID: 33644570 PMCID: PMC7905812 DOI: 10.1021/acsomega.0c05306] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/30/2020] [Accepted: 01/25/2021] [Indexed: 05/05/2023]
Abstract
The electrocatalytic performance of carbon paste electrode (CPE) modified with ferrocene-derivative (ethyl2-(4-ferrocenyl[1,2,3]triazol-1-yl)acetate), ionic liquid (n-hexyl-3-methylimidazolium hexafluorophosphate), and CoS2-carbon nanotube nanocomposite (EFTA/IL/CoS2-CNT/CPE) was investigated for the electrocatalytic detection of hydrazine. CoS2-CNT nanocomposite was characterized by field emission scanning electron microscopy, X-ray powder diffraction, and transmission electron microscopy. According to the results of cyclic voltammetry, the EFTA/IL/CoS2-CNT-integrated CPE has been accompanied by greater catalytic activities for hydrazine oxidation compared to the other electrodes in phosphate buffer solution at a pH 7.0 as a result of the synergistic impact of fused ferrocene-derivative, IL, and nanocomposite. The sensor responded linearly with increasing concentration of hydrazine from 0.03 to 500.0 μM with a higher sensitivity (0.073 μA μM-1) and lower limit of detection (LOD, 0.015 μM). Furthermore, reasonable reproducibility, lengthy stability, and excellent selectivity were also attained for the proposed sensor. Finally, EFTA/IL/CoS2-CNT/CPE was applied for the detection of hydrazine in water samples, and good recoveries varied from 96.7 to 103.0%.
Collapse
Affiliation(s)
- Somayeh Tajik
- Research Center
for Tropical and Infectious Diseases, Kerman
University of Medical Sciences, Kerman 7617934111, Iran
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High
Technology and Environmental Sciences, Graduate
University of Advanced Technology, Kerman 7631818356, Iran
| | - Rahman Hosseinzadeh
- Department of Organic Chemistry, Faculty of Chemistry, University of Mazandaran, Babolsar 47416-1467, Iran
| | - Abbas Aghaei Afshar
- Research Center for Tropical and Infectious Diseases, Kerman University of Medical Sciences, Kerman 1234, Iran
| | - Rajender S. Varma
- Regional Center of Advanced Technologies
and Materials, Palacky University, Š lechtitelů 27, 783 71 Olomouc, Czech Republic
| | - Ho Won Jang
- Department of Materials Science and Engineering, Research
Institute of Advanced Materials, Seoul National
University, Seoul 08826, Republic of Korea
| | - Mohammadreza Shokouhimehr
- Department of Materials Science and Engineering, Research
Institute of Advanced Materials, Seoul National
University, Seoul 08826, Republic of Korea
| |
Collapse
|
47
|
DNA Electrochemical Biosensors for In Situ Probing of Pharmaceutical Drug Oxidative DNA Damage. SENSORS 2021; 21:s21041125. [PMID: 33562790 PMCID: PMC7915242 DOI: 10.3390/s21041125] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 01/22/2021] [Revised: 02/01/2021] [Accepted: 02/01/2021] [Indexed: 12/20/2022]
Abstract
Deoxyribonucleic acid (DNA) electrochemical biosensors are devices that incorporate immobilized DNA as a molecular recognition element on the electrode surface, and enable probing in situ the oxidative DNA damage. A wide range of DNA electrochemical biosensor analytical and biotechnological applications in pharmacology are foreseen, due to their ability to determine in situ and in real-time the DNA interaction mechanisms with pharmaceutical drugs, as well as with their degradation products, redox reaction products, and metabolites, and due to their capacity to achieve quantitative electroanalytical evaluation of the drugs, with high sensitivity, short time of analysis, and low cost. This review presents the design and applications of label-free DNA electrochemical biosensors that use DNA direct electrochemical oxidation to detect oxidative DNA damage. The DNA electrochemical biosensor development, from the viewpoint of electrochemical and atomic force microscopy (AFM) characterization, and the bottom-up immobilization of DNA nanostructures at the electrode surface, are described. Applications of DNA electrochemical biosensors that enable the label-free detection of DNA interactions with pharmaceutical compounds, such as acridine derivatives, alkaloids, alkylating agents, alkylphosphocholines, antibiotics, antimetabolites, kinase inhibitors, immunomodulatory agents, metal complexes, nucleoside analogs, and phenolic compounds, which can be used in drug analysis and drug discovery, and may lead to future screening systems, are reviewed.
Collapse
|
48
|
Tajik S, Dourandish Z, Jahani PM, Sheikhshoaie I, Beitollahi H, Shahedi Asl M, Jang HW, Shokouhimehr M. Recent developments in voltammetric and amperometric sensors for cysteine detection. RSC Adv 2021; 11:5411-5425. [PMID: 35423079 PMCID: PMC8694840 DOI: 10.1039/d0ra07614g] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Accepted: 12/06/2020] [Indexed: 12/27/2022] Open
Abstract
This review article aims to provide an overview of the recent advances in the voltammetric and amperometric sensing of cysteine (Cys). The introduction summarizes the important role of Cys as an essential amino acid, techniques for its sensing, and the utilization of electrochemical methods and chemically modified electrodes for its determination. The main section covers voltammetric and amperometric sensing of Cys based on glassy carbon electrodes, screen printed electrodes, and carbon paste electrodes, modified with various electrocatalytic materials. The conclusion section discusses the current challenges of Cys determination and the future perspectives.
Collapse
Affiliation(s)
- Somayeh Tajik
- Research Center for Tropical and Infectious Diseases, Kerman University of Medical Sciences Kerman Iran
| | - Zahra Dourandish
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman Kerman 76175-133 Iran
| | | | - Iran Sheikhshoaie
- Department of Chemistry, Faculty of Science, Shahid Bahonar University of Kerman Kerman 76175-133 Iran
| | - Hadi Beitollahi
- Environment Department, Institute of Science and High Technology and Environmental Sciences, Graduate University of Advanced Technology Kerman Iran
| | - Mehdi Shahedi Asl
- Marine Additive Manufacturing Centre of Excellence (MAMCE), University of New Brunswick Fredericton NB E3B 5A1 Canada
| | - Ho Won Jang
- Department of Materials Science and Engineering, Research Institute of Advanced Materials, Seoul National University Seoul 08826 Republic of Korea
| | - Mohammadreza Shokouhimehr
- Department of Materials Science and Engineering, Research Institute of Advanced Materials, Seoul National University Seoul 08826 Republic of Korea
| |
Collapse
|
49
|
Lin X, Xiong M, Zhang J, He C, Ma X, Zhang H, Kuang Y, Yang M, Huang Q. Carbon dots based on natural resources: Synthesis and applications in sensors. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105604] [Citation(s) in RCA: 49] [Impact Index Per Article: 12.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
50
|
Brodowski M, Kowalski M, Skwarecka M, Pałka K, Skowicki M, Kula A, Lipiński T, Dettlaff A, Ficek M, Ryl J, Dziąbowska K, Nidzworski D, Bogdanowicz R. Highly selective impedimetric determination of Haemophilus influenzae protein D using maze-like boron-doped carbon nanowall electrodes. Talanta 2021; 221:121623. [DOI: 10.1016/j.talanta.2020.121623] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/25/2020] [Revised: 08/27/2020] [Accepted: 08/31/2020] [Indexed: 12/22/2022]
|