1
|
Tejwani A, Sonkar U, Shrivas K, Tandey K, Karbhal I, Deb MK, Pervez S. Differential pulse voltametric detection of dopamine using polyaniline-functionalized graphene oxide/silica nanocomposite for point-of-care diagnostics. RSC Adv 2025; 15:15870-15878. [PMID: 40370845 PMCID: PMC12076068 DOI: 10.1039/d5ra00714c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2025] [Accepted: 05/05/2025] [Indexed: 05/16/2025] Open
Abstract
In this study, a novel composite material, GO/SiO2@PANI, was synthesized and employed as an electrochemical sensor for the detection of dopamine in urine using differential pulse voltammetry (DPV). This work introduced a first-time combination of graphene oxide (GO) with silicon dioxide (SiO2) and the conducting polymer polyaniline (PANI) to improve dopamine detection. The composite material was synthesized using an in situ polymerization process, ensuring uniform integration of GO/SiO2 with PANI. The GO/SiO2@PANI-modified glassy carbon electrode (GCE) demonstrated a notable electrocatalytic activity for dopamine detection using DPV and CV. The performance of the sensor was evaluated across a range of dopamine concentrations, showing a linear detection range between 2 and 12 μM with a detection limit of 1.7 μM and relative standard deviation of 2.5%. The material's performance was attributed to the combined effects of graphene's surface area, PANI's conducting properties, and the structural integrity provided by SiO2 nanoparticles (NPs). Additionally, the sensor's robustness and high selectivity were confirmed through tests with synthetic urine samples, where dopamine concentrations were detected with high accuracy. This work provides a promising avenue for the development of low-cost and efficient dopamine sensors for clinical applications.
Collapse
Affiliation(s)
- Ankita Tejwani
- School of Studies in Chemistry, Pt. Ravishankar Shukla University Raipur CG 492010 India
| | - Urvashi Sonkar
- School of Studies in Chemistry, Pt. Ravishankar Shukla University Raipur CG 492010 India
| | - Kamlesh Shrivas
- School of Studies in Chemistry, Pt. Ravishankar Shukla University Raipur CG 492010 India
| | - Khushali Tandey
- School of Studies in Chemistry, Pt. Ravishankar Shukla University Raipur CG 492010 India
| | - Indrapal Karbhal
- School of Studies in Chemistry, Pt. Ravishankar Shukla University Raipur CG 492010 India
| | - Manas Kanti Deb
- School of Studies in Chemistry, Pt. Ravishankar Shukla University Raipur CG 492010 India
| | - Shamsh Pervez
- School of Studies in Chemistry, Pt. Ravishankar Shukla University Raipur CG 492010 India
| |
Collapse
|
2
|
Kabir MH, Pabel MY, Bristy NT, Salam MA, Bashar MS, Yasmin S. From e-waste to eco-sensors: synthesis of reduced graphene oxide/ZnO from discarded batteries for a rapid electrochemical bisphenol A sensor. RSC Adv 2024; 14:36073-36083. [PMID: 39529742 PMCID: PMC11551914 DOI: 10.1039/d4ra04046e] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2024] [Accepted: 10/25/2024] [Indexed: 11/16/2024] Open
Abstract
Improper disposal of used dry cell batteries and the leaching of bisphenol A (BPA), a prevalent endocrine disruptor present in food packaging, into surface water pose a significant threat to both the environment and drinking water, threatening the sustainability of the ecosystem. Thus, it is imperative to manage detrimental e-waste and regularly monitor BPA using a sensitive and reliable technique. This study proposes a cost-effective reduced graphene oxide/zinc oxide (rGO/ZnO) nanohybrid, entirely synthesized from electronic waste, for electrochemically detecting BPA in an aqueous medium. Graphite and metallic Zn precursors obtained from discarded batteries were employed to synthesize rGO/ZnO. The successful characterization of the prepared rGO and rGO/ZnO nanohybrid was conducted through different state-of-the-art techniques. An rGO/ZnO-modified glassy carbon electrode (GCE) exhibited superior conductivity and a larger surface area. Voltammetric study at the rGO/ZnO-modified GCE successfully detected BPA in an aqueous medium, demonstrating a one-electron and proton pathway for BPA oxidation. The sensor demonstrated a linear response within the concentration range of 1-30 μM, with a limit of detection of 0.98 nM and sensitivity of 0.055 μA μM-1. The developed electrode could also detect BPA in real water samples with reasonable recovery. These findings imply that the developed sensor has the potential to be a sensitive, practical, and economical monitoring system for BPA in water.
Collapse
Affiliation(s)
- Md Humayun Kabir
- Institute of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR) Dhanmondi Dhaka-1205 Bangladesh
| | - Md Yeasin Pabel
- Institute of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR) Dhanmondi Dhaka-1205 Bangladesh
| | - Nishat Tasnim Bristy
- Institute of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR) Dhanmondi Dhaka-1205 Bangladesh
- Department of Chemistry, University of Dhaka Dhaka-1000 Bangladesh
| | - Md Abdus Salam
- Department of Chemistry, University of Dhaka Dhaka-1000 Bangladesh
| | - Muhammad Shahriar Bashar
- Institute of Energy Research & Development (IERD), Bangladesh Council of Scientific and Industrial Research (BCSIR) Dhanmondi Dhaka-1205 Bangladesh
| | - Sabina Yasmin
- Institute of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR) Dhanmondi Dhaka-1205 Bangladesh
| |
Collapse
|
3
|
Hossain MS, Padmanathan N, Badal MMR, Razeeb KM, Jamal M. Highly Sensitive Potentiometric pH Sensor Based on Polyaniline Modified Carbon Fiber Cloth for Food and Pharmaceutical Applications. ACS OMEGA 2024; 9:40122-40133. [PMID: 39346860 PMCID: PMC11425811 DOI: 10.1021/acsomega.4c06090] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/01/2024] [Revised: 08/30/2024] [Accepted: 09/02/2024] [Indexed: 10/01/2024]
Abstract
This study introduces a potentiometric pH sensor that is extremely sensitive and specifically designed for food and pharmaceutical applications. The sensor utilizes a pH-sensitive interface fabricated by electropolymerizing polyaniline (PANI) on carbon fiber cloth (CFC). Structural and morphological analyses of PANI-CFC and CFC have been conducted by using X-ray diffraction (XRD), field emission scanning electron microscopy (FESEM), and X-ray photoelectron spectroscopy (XPS). The investigation of the functional groups was conducted by using Fourier transform infrared spectroscopy (FTIR) and Raman spectroscopy. The electrochemical characteristics were assessed by utilization of cyclic voltammetry (CV) and open-circuit potential (OCP) measurements in a three-electrode configuration. The sensor exhibited a sensitivity of 60.9 mV/pH, while retaining consistent performance within the pH range of 4 to 12. The repeatability and robustness of the sensors were verified. The accuracy of the PANI-CFC sensor was confirmed by validation using real samples, demonstrating its compatibility with commercially available pH sensors. The application of density functional theory (DFT) calculations revealed an interaction energy of -173.2886 kcal/mol, indicating a strong affinity of H+ ions towards PANI-CFC electrode. Further investigation was conducted to examine the chemical reactivity of PANI, revealing a HOMO-LUMO energy gap of -0.98 eV. This study highlights the PANI-CFC sensor as a reliable and efficient pH-sensing platform for food and pharmaceuticals applications, performing robustly in both laboratory and real-world settings.
Collapse
Affiliation(s)
- Md. Sanwar Hossain
- Department
of Chemistry, Khulna University of Engineering
& Technology, Khulna 9203, Bangladesh
| | - Narayanasamy Padmanathan
- Micro-NanoSystems
Centre, Tyndall National Institute, University
College Cork, Dyke Parade, Lee Maltings, Cork T12 R5CP, Ireland
| | - Md. Mizanur R. Badal
- Department
of Chemistry, Khulna University of Engineering
& Technology, Khulna 9203, Bangladesh
| | - Kafil M. Razeeb
- Micro-NanoSystems
Centre, Tyndall National Institute, University
College Cork, Dyke Parade, Lee Maltings, Cork T12 R5CP, Ireland
| | - Mamun Jamal
- Department
of Chemistry, Khulna University of Engineering
& Technology, Khulna 9203, Bangladesh
| |
Collapse
|
4
|
Yasmin S, Azam MG, Hossain MS, Akhtar US, Kabir MH. Efficient removal of ciprofloxacin from aqueous solution using Zn-C battery derived graphene oxide enhanced by hydrogen bonding, electrostatic and π-π interaction. Heliyon 2024; 10:e33317. [PMID: 39022076 PMCID: PMC11253669 DOI: 10.1016/j.heliyon.2024.e33317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2024] [Revised: 06/07/2024] [Accepted: 06/19/2024] [Indexed: 07/20/2024] Open
Abstract
In this study, graphene oxide (GO) derived from waste Zinc-Carbon (Zn-C) batteries was proposed for the efficient removal of antibiotics from the aqueous solution. Ciprofloxacin (CIP) antibiotic was selected as a typical contaminants. GO was prepared via an economical and environment-friendly route by using carbon rods from waste Zn-C batteries as the precursor. Characterization techniques were applied to determine the properties of as prepared GO. Effects of pH, contact time, and adsorbent dose on the adsorption were explored, and an optimum condition was established. Adsorption equilibrium was established in just 20 min for maximum removal of CIP (99.0%) at pH 5.7 for the adsorbent dose of 20 mg L-1 and at the initial concentration of CIP 2.0 mg L-1. The rapid and efficient removal of CIP was greatly influenced by the electrostatic attractions, pi-pi interactions and hydrogen bonding on the surface and edge of GO which was also proved by density functional theory (DFT). Langmuir model showed the best fit among the isotherm models and the calculated maximum adsorption capacity (qm) was 419.62 mg g-1 at 30°C. The kinetic studies also revealed that the adsorption process followed the pseudo-second-order model. The endothermic and spontaneous nature of adsorption was evaluated in thermodynamic studies.
Collapse
Affiliation(s)
- Sabina Yasmin
- Institute of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR), Dhanmondi, Dhaka, 1205, Bangladesh
| | - Md Golam Azam
- Institute of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR), Dhanmondi, Dhaka, 1205, Bangladesh
| | - Md Sanwar Hossain
- Institute of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR), Dhanmondi, Dhaka, 1205, Bangladesh
| | - Umme Sarmeen Akhtar
- Institute of Glass and Ceramic Research and Testing (IGCRT), Bangladesh Council of Scientific and Industrial Research (BCSIR), Dhanmondi, Dhaka, 1205, Bangladesh
| | - Md Humayun Kabir
- Institute of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR), Dhanmondi, Dhaka, 1205, Bangladesh
| |
Collapse
|
5
|
Roy N, Ahmed MS, Lee HK, Jeon S. Intermetallic Pd-Y nanoparticles/N-doped carbon nanotubes as multi-active catalysts for oxygen reduction reaction, ethanol oxidation reaction, and zinc-air batteries. NANOSCALE 2024; 16:7532-7546. [PMID: 38501222 DOI: 10.1039/d3nr06188d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 03/20/2024]
Abstract
Intermetallic nanomaterials are unique in terms of their band gap, atomic-level arrangement, and well-defined stoichiometry, which allows them to exhibit significantly enhanced catalytic performance in electrochemical applications. However, the preparation of durable intermetallic catalysts with a lower content of platinum group metals is challenging, while the lack of control over the loss of active components limits their long-term application due to weak interaction between the support and the nanostructure. Here, we have designed the intermetallic alloyed nanoparticles (NPs) of PdY on N-doped carbon nanotubes (PdY/NCNTs) as a multifunctional catalyst for the oxygen reduction reaction (ORR), the ethanol oxidation reaction (EOR), and zinc-air batteries (ZABs). The strong adhesion through nitrogen ensures the anchoring of alloyed PdY NPs on the NCNTs, which restrains atomic migration and sintering during their conversion to intermetallic phases. This study confirms that there is negligible active site leaching owing to the strong and multiple dative bonds between the NCNTs and PdY NPs. Therefore, this catalyst exhibits remarkable catalytic activity, resulting in a mass activity of 1317 and 2902 mA mgPd-1 at jk and jf for the ORR and the EOR, respectively, and remains stable for a longer period. In addition, the PdY/NCNT-containing air cathode-fabricated ZAB achieved a higher power density (0.236 W cm-2) compared to the benchmark Pt/C.
Collapse
Affiliation(s)
- Nipa Roy
- Department of Chemistry and Institute of Basic Science, Chonnam National University, Gwangju 500-757, Republic of Korea.
- Department of Physics, Yeungnam University, Gyeongsan 38541, Republic of Korea
| | - Mohammad Shamsuddin Ahmed
- Institute of Energy Studies, University of North Dakota, Grand Forks, North Dakota, 58202, USA
- Department of Materials Science and Engineering, Chonnam National University, Gwangju 61186, Republic of Korea
| | - Hyo Kyoung Lee
- School of Architecture, Chosun University, 309 Pilmun-daero, Dong-gu, Gwangju, 61452, Republic of Korea
| | - Seungwon Jeon
- Department of Chemistry and Institute of Basic Science, Chonnam National University, Gwangju 500-757, Republic of Korea.
| |
Collapse
|
6
|
Liu W, Zhao Z, Hou S, Lu Y. Alkaline liquid-derived Na xTi11.5MoVO x/C-40 material with controlled electron transfer rate for sensitive electrochemical detection of dopamine. Talanta 2024; 270:125540. [PMID: 38096738 DOI: 10.1016/j.talanta.2023.125540] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/15/2023] [Revised: 12/05/2023] [Accepted: 12/08/2023] [Indexed: 01/27/2024]
Abstract
The neurotransmitter dopamine (DA) is associated with many physiological and pathological processes, so the importance of low detection limits and high sensitivity analysis cannot be overstated, especially for early disease detection. Here, 2 M NaOH aqueous solution is used to precipitate metal ions in an ethanol solution containing carbon black (CB), and then nanocomposite catalysts (NaxTi11.5MoVOx/C-40 (40 denoted as 40 mg CB)) were obtained by calcining the precipitation. When used for DA detection, NaxVOx acts as the main active site for electrochemical oxidation of DA and NaxTi11.5MoOx plays a role in facilitating the binding of DA to the active site and stabilizing the active site. The NaxTi11.5MoVOx/C-40 electrochemical biosensor has a limit of detection (LOD) of 0.003 μM with a linear range of 0.005-51.665 μM for DA. This sensor can be used to sensitively identify the concentration of DA in human blood and urine. Catalysts containing varying amounts of CB exhibit diverse electron transfer rates, and surprisingly, we found that the appropriate electron transfer rate is optimal for the detection of low concentrations of DA. Because the performance of the electrochemical biosensors is affected by both the activity of the catalysts and the accuracy of the electrochemical testing instrumentation. To better explain this phenomenon, we propose the concept of resolution (Rn) and present the formula to derive it, offering a new approach to evaluating the performance of electrochemical biosensors.
Collapse
Affiliation(s)
- Wenwen Liu
- School of Material Science and Engineering, University of Jinan, Jinan, 250022, Shandong, China.
| | - Zhenlu Zhao
- School of Material Science and Engineering, University of Jinan, Jinan, 250022, Shandong, China; Anhui Laboratory of Functional Coordinated Complexes for Materials Chemistry and Application, School of Chemical and Environmental Engineering, Anhui Polytechnic University, Wuhu, 241000, China.
| | - Shuping Hou
- State Key Lab of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, Changchun, 130022, Jilin, China.
| | - Yizhong Lu
- School of Material Science and Engineering, University of Jinan, Jinan, 250022, Shandong, China.
| |
Collapse
|
7
|
Hossain MS, Kabir MH, Ali Shaikh MA, Haque MA, Yasmin S. Ultrafast and simultaneous removal of four tetracyclines from aqueous solutions using waste material-derived graphene oxide-supported cobalt-iron magnetic nanocomposites. RSC Adv 2024; 14:1431-1444. [PMID: 38174255 PMCID: PMC10763703 DOI: 10.1039/d3ra07597d] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/07/2023] [Accepted: 12/12/2023] [Indexed: 01/05/2024] Open
Abstract
In this work, a graphene oxide-supported cobalt-iron oxide (GO/Co-Fe) magnetic nanocomposite was successfully synthesized using waste dry cells for the efficient and simultaneous removal of tetracycline (TC), chlortetracycline (CTC), oxytetracycline (OTC), and doxycycline (DTC) from aqueous solutions. The GO/Co-Fe nanocomposite was thoroughly characterized using Fourier transform infrared spectroscopy, vibrating sample magnetometry, X-ray diffraction, field emission scanning electron microscopy, energy-dispersive X-ray spectroscopy, transmission electron microscopy, X-ray photoelectron spectroscopy, and zeta potential analysis. This multi-faceted characterization provided clean insights into the composition and properties of the synthesized nanocomposite. The adsorption of tetracyclines (TCs) was systematically investigated by assessing the influence of critical factors, such as adsorbent dosage, contact duration, initial pH of the solution, initial concentration, and temperature. The GO/Co-Fe adsorbent showed high removal efficiencies of 94.1% TC, 94.32% CTC, 94.22% OTC, and 96.94% DTC within 30 s contact period. The maximum removal efficiency of TCs was found at a low adsorbent dose of 0.15 g L-1. Notably, this superior removal efficiency was achieved at neutral pH and room temperature, demonstrating the adsorbent's efficacy under environmentally viable conditions. The kinetic studies demonstrated that the adsorption process was fitted satisfactorily with the pseudo-second-order model. Additionally, the adsorption behaviour of TCs on the GO/Co-Fe adsorbent was assessed by isotherm models, Langmuir and Freundlich. The experimental data followed the Langmuir isotherm, signifying a monolayer adsorption mechanism on the surface of the adsorbent. The adsorption capacities (qm) of GO/Co-Fe for TC, CTC, OTC and DTC were determined to be 64.10, 71.43, 72.46 and 99.01 mg g-1, respectively. Importantly, the GO/Co-Fe adsorbent showed reusability capabilities. The super magnetic properties of GO/Co-Fe made it easy to use for several cycles. These results clearly establish GO/Co-Fe as an exceptionally effective adsorbent for the removal of TCs from aqueous systems, highlighting its great potentiality in water treatment applications.
Collapse
Affiliation(s)
- Md Sohag Hossain
- Institute of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR) Dhanmondi Dhaka-1205 Bangladesh
- Department of Chemistry, University of Dhaka Dhaka 1000 Bangladesh
| | - Md Humayun Kabir
- Institute of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR) Dhanmondi Dhaka-1205 Bangladesh
| | - Md Aftab Ali Shaikh
- Institute of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR) Dhanmondi Dhaka-1205 Bangladesh
- Department of Chemistry, University of Dhaka Dhaka 1000 Bangladesh
| | - Md Anamul Haque
- Department of Chemistry, University of Dhaka Dhaka 1000 Bangladesh
| | - Sabina Yasmin
- Institute of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR) Dhanmondi Dhaka-1205 Bangladesh
| |
Collapse
|
8
|
Wang YZ, Hsieh TH, Huang YC, Ho KS. 2,6-Diaminopyridine-Based Polyurea as an ORR Electrocatalyst of an Anion Exchange Membrane Fuel Cell. Polymers (Basel) 2023; 15:polym15040915. [PMID: 36850199 PMCID: PMC9965045 DOI: 10.3390/polym15040915] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2023] [Revised: 01/25/2023] [Accepted: 02/08/2023] [Indexed: 02/15/2023] Open
Abstract
In order to yield more Co(II), 2,6-diaminopyridine (DAP) was polymerized with 4,4-methylene diphenyl diisocyanates (MDI) in the presence of Co(II) to obtain a Co-complexed polyurea (Co-PUr). The obtained Co-PUr was calcined to become Co, N-doped carbon (Co-N-C) as the cathode catalyst of an anion exchange membrane fuel cell (AEMFC). High-resolution transmission electron microscopy (HR-TEM) of Co-N-C indicated many Co-Nx (Co covalent bonding with several nitrogen) units in the Co-N-C matrix. X-ray diffraction patterns showed that carbon and cobalt crystallized in the Co-N-C catalysts. The Raman spectra showed that the carbon matrix of Co-N-C became ordered with increased calcination temperature. The surface area (dominated by micropores) of Co-N-Cs also increased with the calcination temperature. The non-precious Co-N-C demonstrated comparable electrochemical properties (oxygen reduction reaction: ORR) to commercial precious Pt/C, such as high on-set and half-wave voltages, high limited reduction current density, and lower Tafel slope. The number of electrons transferred in the cathode was close to four, indicating complete ORR. The max. power density (Pmax) of the single cell with the Co-N-C cathode catalyst demonstrated a high value of 227.7 mWcm-2.
Collapse
Affiliation(s)
- Yen-Zen Wang
- Department of Chemical and Materials Engineering, National Yu-Lin University of Science & Technology, 123, Sec. 3, University Rd., Yun-Lin 64301, Taiwan
| | - Tar-Hwa Hsieh
- Department of Chemical and Materials Engineering, National Kaohsiung University of Science and Technology, 415, Chien-Kuo Road, Kaohsiung 80782, Taiwan
| | - Yu-Chang Huang
- Department of Chemical and Materials Engineering, National Kaohsiung University of Science and Technology, 415, Chien-Kuo Road, Kaohsiung 80782, Taiwan
| | - Ko-Shan Ho
- Department of Chemical and Materials Engineering, National Kaohsiung University of Science and Technology, 415, Chien-Kuo Road, Kaohsiung 80782, Taiwan
- Correspondence:
| |
Collapse
|
9
|
Upoma B, Yasmin S, Ali Shaikh MA, Jahan T, Haque MA, Moniruzzaman M, Kabir MH. A Fast Adsorption of Azithromycin on Waste-Product-Derived Graphene Oxide Induced by H-Bonding and Electrostatic Interactions. ACS OMEGA 2022; 7:29655-29665. [PMID: 36061663 PMCID: PMC9434760 DOI: 10.1021/acsomega.2c01919] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/29/2022] [Accepted: 08/11/2022] [Indexed: 05/12/2023]
Abstract
Graphene oxide (GO) was prepared from the graphite electrode of waste dry cells, and the application of the prepared GO as a potential adsorbent for rapid and effective removal of an antibiotic, azithromycin (AZM), has been investigated. The synthesis process of GO is very simple, cost-effective, and eco-friendly. As-prepared GO is characterized by field-emission scanning electron microscopy, energy-dispersive X-ray, transmission electron microscopy, X-ray diffractometry, Fourier transform infrared spectroscopy, elemental analysis, Brunauer-Emmett-Teller sorptometry, and zeta potential analysis. The obtained GO has been employed for removal of the widely used AZM antibiotic from an aqueous solution. The quantitative analysis of AZM before and after adsorption has been carried out by liquid chromatography tandem mass spectrometry. The adsorption of AZM by GO was performed in a batch of experiments where the effects of adsorbent (GO) dose, solution pH, temperature, and contact time were investigated. Under optimum conditions (pH = 7.0, contact time = 15 min, and adsorbent dose = 0.25 g/L), 98.8% AZM was removed from the aqueous solution. The rapid and effective removal of AZM was significantly controlled by the electrostatic attractions and hydrogen bonding on the surface of GO. Adsorption isotherms of AZM onto GO were fitted well with the Freundlich isotherm model, while the kinetic data were fitted perfectly with the pseudo-second order. Therefore, the simple, cost-effective, and eco-friendly synthesis of GO from waste material could be applicable to fabricate an effective and promising low-cost adsorbent for removal of AZM from aqueous media.
Collapse
Affiliation(s)
- Bushra
Parvin Upoma
- Institute
of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR), Dhanmondi, Dhaka 1205, Bangladesh
| | - Sabina Yasmin
- Institute
of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR), Dhanmondi, Dhaka 1205, Bangladesh
| | - Md. Aftab Ali Shaikh
- Institute
of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR), Dhanmondi, Dhaka 1205, Bangladesh
- Department
of Chemistry, University of Dhaka, Dhaka 1000, Bangladesh
| | - Tajnin Jahan
- Institute
of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR), Dhanmondi, Dhaka 1205, Bangladesh
| | - Md. Anamul Haque
- Department
of Chemistry, University of Dhaka, Dhaka 1000, Bangladesh
| | | | - Md Humayun Kabir
- Institute
of National Analytical Research and Service (INARS), Bangladesh Council of Scientific and Industrial Research (BCSIR), Dhanmondi, Dhaka 1205, Bangladesh
- Central
Analytical and Research Facilities (CARF), BCSIR, Dhaka 1205, Bangladesh
| |
Collapse
|
10
|
Wei J, Liu C, Wu T, Zeng W, Hu B, Zhou S, Wu L. A review of current status of ratiometric molecularly imprinted electrochemical sensors: From design to applications. Anal Chim Acta 2022; 1230:340273. [DOI: 10.1016/j.aca.2022.340273] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2022] [Revised: 08/13/2022] [Accepted: 08/16/2022] [Indexed: 12/01/2022]
|
11
|
2, 6-Diaminopyridine decorated reduced graphene oxide as integrated electrode with excellent electrochemical properties for aqueous supercapacitors. Electrochim Acta 2022. [DOI: 10.1016/j.electacta.2021.139725] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
|
12
|
Zhu Y, Tian Q, Li X, Wu L, Yu A, Lai G, Fu L, Wei Q, Dai D, Jiang N, Li H, Ye C, Lin CT. A Double-Deck Structure of Reduced Graphene Oxide Modified Porous Ti 3C 2T x Electrode towards Ultrasensitive and Simultaneous Detection of Dopamine and Uric Acid. BIOSENSORS 2021; 11:bios11110462. [PMID: 34821678 PMCID: PMC8615994 DOI: 10.3390/bios11110462] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2021] [Revised: 11/06/2021] [Accepted: 11/15/2021] [Indexed: 05/08/2023]
Abstract
Considering the vital physiological functions of dopamine (DA) and uric acid (UA) and their coexistence in the biological matrix, the development of biosensing techniques for their simultaneous and sensitive detection is highly desirable for diagnostic and analytical applications. Therefore, Ti3C2Tx/rGO heterostructure with a double-deck layer was fabricated through electrochemical reduction. The rGO was modified on a porous Ti3C2Tx electrode as the biosensor for the detection of DA and UA simultaneously. Debye length was regulated by the alteration of rGO mass on the surface of the Ti3C2Tx electrode. Debye length decreased with respect to the rGO electrode modified with further rGO mass, indicating that fewer DA molecules were capable of surpassing the equilibrium double layer and reaching the surface of rGO to achieve the voltammetric response of DA. Thus, the proposed Ti3C2Tx/rGO sensor presented an excellent performance in detecting DA and UA with a wide linear range of 0.1-100 μM and 1-1000 μM and a low detection limit of 9.5 nM and 0.3 μM, respectively. Additionally, the proposed Ti3C2Tx/rGO electrode displayed good repeatability, selectivity, and proved to be available for real sample analysis.
Collapse
Affiliation(s)
- Yangguang Zhu
- Laboratory of Environmental Biotechnology, School of Environmental and Civil Engineering, Jiangnan University, Wuxi 214122, China;
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China; (D.D.); (N.J.); (H.L.)
| | - Qichen Tian
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou 310032, China;
| | - Xiufen Li
- Laboratory of Environmental Biotechnology, School of Environmental and Civil Engineering, Jiangnan University, Wuxi 214122, China;
- Correspondence: (X.L.); (C.Y.); (C.-T.L.)
| | - Lidong Wu
- Key Laboratory of Control of Quality and Safety for Aquatic Products, Chinese Academy of Fishery Sciences, Beijing 100141, China;
| | - Aimin Yu
- Department of Chemistry and Biotechnology, Faculty of Science, Engineering and Technology, Swinburne University of Technology, Hawthorn, VIC 3122, Australia;
| | - Guosong Lai
- Department of Chemistry, Hubei Normal University, Huangshi 435002, China;
| | - Li Fu
- College of Materials and Environmental Engineering, Hangzhou Dianzi University, Hangzhou 310018, China;
| | - Qiuping Wei
- School of Materials Science and Engineering, Central South University, Changsha 410083, China;
| | - Dan Dai
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China; (D.D.); (N.J.); (H.L.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Nan Jiang
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China; (D.D.); (N.J.); (H.L.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - He Li
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China; (D.D.); (N.J.); (H.L.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
| | - Chen Ye
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China; (D.D.); (N.J.); (H.L.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- Correspondence: (X.L.); (C.Y.); (C.-T.L.)
| | - Cheng-Te Lin
- Key Laboratory of Marine Materials and Related Technologies, Zhejiang Key Laboratory of Marine Materials and Protective Technologies, Ningbo Institute of Materials Technology and Engineering (NIMTE), Chinese Academy of Sciences, Ningbo 315201, China; (D.D.); (N.J.); (H.L.)
- Center of Materials Science and Optoelectronics Engineering, University of Chinese Academy of Sciences, Beijing 100049, China
- Correspondence: (X.L.); (C.Y.); (C.-T.L.)
| |
Collapse
|
13
|
Islam S, Shaheen Shah S, Naher S, Ali Ehsan M, Aziz MA, Ahammad AJS. Graphene and Carbon Nanotube-based Electrochemical Sensing Platforms for Dopamine. Chem Asian J 2021; 16:3516-3543. [PMID: 34487610 DOI: 10.1002/asia.202100898] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/04/2021] [Revised: 09/05/2021] [Indexed: 12/24/2022]
Abstract
Dopamine (DA) is an important neurotransmitter, which is created and released from the central nervous system. It plays a crucial role in human activities, like cognition, emotions, and response to anything. Maladjustment of DA in human blood serum results in different neural diseases, like Parkinson's and Schizophrenia. Consequently, researchers have started working on DA detection in blood serum, which is undoubtedly a hot research area. Electrochemical sensing techniques are more promising to detect DA in real samples. However, utilizing conventional electrodes for selective determination of DA encounters numerous problems due to the coexistence of other materials, such as uric acid and ascorbic acid, which have an oxidation potential close to DA. To overcome such problems, researchers have put their focus on the modification of bare electrodes. The aim of this review is to present recent advances in modifications of most used bare electrodes with carbonaceous materials, especially graphene, its derivatives, and carbon nanotubes, for electrochemical detection of DA. A brief discussion about the mechanistic phenomena at the electrode interface has also been included in this review.
Collapse
Affiliation(s)
- Santa Islam
- Department of Chemistry, Jagannath University, Dhaka, 1100, Bangladesh
| | - Syed Shaheen Shah
- Interdisciplinary Research Center for Hydrogen and Energy Storage (IRC-HES), King Fahd University of Petroleum & Minerals, KFUPM Box 5040, Dhahran, 31261, Saudi Arabia.,Physics Department, King Fahd University of Petroleum & Minerals, KFUPM Box 5047, Dhahran, 31261, Saudi Arabia
| | - Shamsun Naher
- Department of Chemistry, Jagannath University, Dhaka, 1100, Bangladesh
| | - Muhammad Ali Ehsan
- Interdisciplinary Research Center for Hydrogen and Energy Storage (IRC-HES), King Fahd University of Petroleum & Minerals, KFUPM Box 5040, Dhahran, 31261, Saudi Arabia
| | - Md Abdul Aziz
- Interdisciplinary Research Center for Hydrogen and Energy Storage (IRC-HES), King Fahd University of Petroleum & Minerals, KFUPM Box 5040, Dhahran, 31261, Saudi Arabia
| | - A J Saleh Ahammad
- Department of Chemistry, Jagannath University, Dhaka, 1100, Bangladesh
| |
Collapse
|
14
|
Thomas J, Anitha P, Thomas T, Thomas N. Electrocatalytic sensing of dopamine: How the Co content in porous LaNixCoxO3 perovskite influences sensitivity? Microchem J 2021. [DOI: 10.1016/j.microc.2021.106443] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
15
|
Zhumasheva N, Kudreeva L, Kosybayeva D. Molybdenum oxide based sensors. CHEMICAL BULLETIN OF KAZAKH NATIONAL UNIVERSITY 2021. [DOI: 10.15328/cb1164] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022] Open
Abstract
In this review article were considered the works of electrochemical sensors modified with molybdenum oxide. The work of sensors based on molybdenum oxide was systematized, a comparison table was developed, the sensors were classified according to the purpose of use. Methods of molybdenum oxide synthesis used to modify the working electrode in electrochemical sensors were considered. The various methods have been used to synthesize molybdenum oxide, such as a thermal, hydrothermal, electrochemical, electric spark, pulsed laser method, acid condensation, electrophoretic precipitation, pulse potential precipitation. The main parameters of the molybdenum oxide modified sensors, such as the detection limit, linear range, response time, sensitivity, and other parameters were compared. As a result of studies, it was found that molybdenum oxide is selected as a modifying material in electrochemical sensors due to the unique physicochemical properties of molybdenum oxide, in particular because of mechanical strength, electrical conductivity, electro catalytic activity, crystallinity. The features of electrochemical biosensors coated with molybdenum oxide were described for the detection of important compounds in specific samples. Sensors based on molybdenum oxide have been used for detection of glucose, dopamine, ethanol, ascorbic acid, troponin-1, norepinephrine, procalcitonin, L-lactate, bromate, chlorate, E110, tartrazine, hydrochlorothiazide, human epidermal growth factor-2, lithium,sodium,potassium. This paper provides general summarized information about current aspects of research works related to electrochemical sensors based on molybdenum oxide.
Collapse
|
16
|
Molybdenum oxide modified montmorillonite K10 clay as novel solid acid for flow synthesis of ionone isomers. MOLECULAR CATALYSIS 2021. [DOI: 10.1016/j.mcat.2020.111362] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
17
|
Terán-Alcocer Á, Bravo-Plascencia F, Cevallos-Morillo C, Palma-Cando A. Electrochemical Sensors Based on Conducting Polymers for the Aqueous Detection of Biologically Relevant Molecules. NANOMATERIALS (BASEL, SWITZERLAND) 2021; 11:252. [PMID: 33478121 PMCID: PMC7835872 DOI: 10.3390/nano11010252] [Citation(s) in RCA: 36] [Impact Index Per Article: 9.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 12/23/2020] [Revised: 01/13/2021] [Accepted: 01/14/2021] [Indexed: 12/12/2022]
Abstract
Electrochemical sensors appear as low-cost, rapid, easy to use, and in situ devices for determination of diverse analytes in a liquid solution. In that context, conducting polymers are much-explored sensor building materials because of their semiconductivity, structural versatility, multiple synthetic pathways, and stability in environmental conditions. In this state-of-the-art review, synthetic processes, morphological characterization, and nanostructure formation are analyzed for relevant literature about electrochemical sensors based on conducting polymers for the determination of molecules that (i) have a fundamental role in the human body function regulation, and (ii) are considered as water emergent pollutants. Special focus is put on the different types of micro- and nanostructures generated for the polymer itself or the combination with different materials in a composite, and how the rough morphology of the conducting polymers based electrochemical sensors affect their limit of detection. Polypyrroles, polyanilines, and polythiophenes appear as the most recurrent conducting polymers for the construction of electrochemical sensors. These conducting polymers are usually built starting from bifunctional precursor monomers resulting in linear and branched polymer structures; however, opportunities for sensitivity enhancement in electrochemical sensors have been recently reported by using conjugated microporous polymers synthesized from multifunctional monomers.
Collapse
Affiliation(s)
- Álvaro Terán-Alcocer
- Grupo de Investigación Aplicada en Materiales y Procesos (GIAMP), School of Chemical Sciences and Engineering, Yachay Tech University, Hda. San José s/n y Proyecto Yachay, 100119 Urcuquí, Ecuador; (Á.T.-A.); (F.B.-P.)
| | - Francisco Bravo-Plascencia
- Grupo de Investigación Aplicada en Materiales y Procesos (GIAMP), School of Chemical Sciences and Engineering, Yachay Tech University, Hda. San José s/n y Proyecto Yachay, 100119 Urcuquí, Ecuador; (Á.T.-A.); (F.B.-P.)
| | - Carlos Cevallos-Morillo
- Facultad de Ciencias Químicas, Universidad Central del Ecuador, Francisco Viteri s/n y Gato Sobral, 170129 Quito, Ecuador;
| | - Alex Palma-Cando
- Grupo de Investigación Aplicada en Materiales y Procesos (GIAMP), School of Chemical Sciences and Engineering, Yachay Tech University, Hda. San José s/n y Proyecto Yachay, 100119 Urcuquí, Ecuador; (Á.T.-A.); (F.B.-P.)
| |
Collapse
|
18
|
Li R, Liang H, Zhu M, Lai M, Wang S, Zhang H, Ye H, Zhu R, Zhang W. Electrochemical dual signal sensing platform for the simultaneous determination of dopamine, uric acid and glucose based on copper and cerium bimetallic carbon nanocomposites. Bioelectrochemistry 2021; 139:107745. [PMID: 33524654 DOI: 10.1016/j.bioelechem.2021.107745] [Citation(s) in RCA: 25] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2020] [Revised: 01/09/2021] [Accepted: 01/12/2021] [Indexed: 02/06/2023]
Abstract
A highly sensitive electrochemical sensor for the simultaneous dual signal determination of dopamine (DA), uric acid (UA) and glucose (Glu) has been obtained using nanocomposites based on the copper and cerium bimetallic nanoparticles and carbon nanomaterials of graphene and single-walled carbon nanotubes in the presence of Tween 20 (GR-SWCNT-Ce-Cu-Tween 20) modified glassy carbon electrode. The surface morphology of the nanocomposites was characterized by scanning electron microscopy (SEM) and X-ray diffraction (XRD), and the electrochemical behavior of the sensor was investigated by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) with potassium ferricyanide as probe. In the coexistence system of DA, UA and Glu, three clear and well-isolated voltammetric peaks were obtained by CV and differential pulse voltammetry (DPV), and oxidation peak currents of DA and UA are positively correlated with their concentrations respectively, while the peak current of Glu is negatively correlated with its concentration. Linearity was obtained in the ranges of 0.1-100 µM for dopamine, 0.08-100 µM for uric acid and 1-1000 µM for glucose with DPV, and the detection limits (S/N = 3) of 0.0072 µM, 0.0063 µM, and 0.095 µM for DA, UA and Glu, respectively. The method was successfully applied to the determination of DA, UA and Glu in blood serum samples, which provided a reference for further sensor research.
Collapse
Affiliation(s)
- Rui Li
- College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou 510006, PR China
| | - Huanru Liang
- College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou 510006, PR China
| | - Mingfang Zhu
- College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou 510006, PR China.
| | - Mushen Lai
- College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou 510006, PR China
| | - Shumei Wang
- College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou 510006, PR China; Key Laboratory of Digital Quality Evaluation of Chinese Materia Medica of State Administration of TCM, Guangzhou 510006, PR China; Engineering & Technology Research Center for Chinese Materia Medica Quality of the Universities of Guangdong Province, Guangzhou, PR China
| | - Hongwu Zhang
- College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou 510006, PR China
| | - Hongqing Ye
- College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou 510006, PR China
| | - Rongkun Zhu
- College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou 510006, PR China
| | - Wenhao Zhang
- College of Pharmacy, Guangdong Pharmaceutical University, Guangzhou Higher Education Mega Center, Guangzhou 510006, PR China
| |
Collapse
|
19
|
Xiao J, Wang H, Li C, Deng K, Li X. A simple dopamine sensor using graphdiyne nanotubes and shortened carbon nanotubes for enhanced preconcentration and electron transfer. Microchem J 2021. [DOI: 10.1016/j.microc.2020.105755] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
|
20
|
Minta D, Moyseowicz A, Gryglewicz S, Gryglewicz G. A Promising Electrochemical Platform for Dopamine and Uric Acid Detection Based on a Polyaniline/Iron Oxide-Tin Oxide/Reduced Graphene Oxide Ternary Composite. Molecules 2020; 25:molecules25245869. [PMID: 33322578 PMCID: PMC7763624 DOI: 10.3390/molecules25245869] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2020] [Revised: 12/02/2020] [Accepted: 12/08/2020] [Indexed: 02/04/2023] Open
Abstract
A ternary polyaniline/Fe2O3-SnO2/reduced graphene oxide (PFSG) nanocomposite was prepared using a simple two-step hydrothermal treatment. The composite was applied as a glassy carbon electrode modifier (GCE) to enhance dopamine (DA) and uric acid (UA) detection. The ternary PFSG composite was compared with its binary precursor Fe2O3-SnO2/reduced graphene oxide (FSG). The influence of the modified GCE electrodes on their performance as a sensing platform was determined. GCE/PFSG showed better sensing parameters than GCE/FSG due to the introduction of polyaniline (PANI), increasing the electrocatalytic properties of the electrode towards the detected analytes. GCE/PFSG enabled the detection of low concentrations of DA (0.076 µM) and UA (1.6 µM). The peak potential separation between DA and UA was very good (180 mV). Moreover, the DA oxidation peak was unaffected even if the concentration of UA was ten times higher. The fabricated sensor showed excellent performance in the simultaneous detection with DA and UA limits of detection: LODDA = 0.15 µM and LODUA = 6.4 µM, and outstanding long-term stability towards DA and UA, holding 100% and 90% of their initial signals respectively, after one month of use.
Collapse
Affiliation(s)
- Daria Minta
- Department of Process Engineering and Technology of Polymer and Carbon Materials, Faculty of Chemistry, Wrocław University of Science and Technology, Gdańska 7/9, 50-344 Wrocław, Poland; (D.M.); (A.M.)
| | - Adam Moyseowicz
- Department of Process Engineering and Technology of Polymer and Carbon Materials, Faculty of Chemistry, Wrocław University of Science and Technology, Gdańska 7/9, 50-344 Wrocław, Poland; (D.M.); (A.M.)
| | - Stanisław Gryglewicz
- Department of Engineering and Technology of Chemical Processes, Faculty of Chemistry, Wrocław University of Science and Technology, Wybrzeże Wyspiańskiego 42, 50-344 Wrocław, Poland;
| | - Grażyna Gryglewicz
- Department of Process Engineering and Technology of Polymer and Carbon Materials, Faculty of Chemistry, Wrocław University of Science and Technology, Gdańska 7/9, 50-344 Wrocław, Poland; (D.M.); (A.M.)
- Correspondence: ; Tel.: +48-71-320-6398; Fax: +48-71-320-6506
| |
Collapse
|
21
|
Fu Y, Zhang Y, Zheng S, Jin W. Bifunctional electrochemical detection of organic molecule and heavy metal at two-dimensional Sn-In2S3 nanocomposite. Microchem J 2020. [DOI: 10.1016/j.microc.2020.105454] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
22
|
Silva AD, Paschoalino WJ, Damasceno JPV, Kubota LT. Structure, Properties, and Electrochemical Sensing Applications of Graphene‐Based Materials. ChemElectroChem 2020. [DOI: 10.1002/celc.202001168] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Affiliation(s)
- Alexsandra D. Silva
- Department of Analytical Chemistry Institute of Chemistry University of Campinas P.O. Box 6154 13084-971 Campinas SP Brazil
| | - Waldemir J. Paschoalino
- Department of Analytical Chemistry Institute of Chemistry University of Campinas P.O. Box 6154 13084-971 Campinas SP Brazil
| | - João Paulo V. Damasceno
- Department of Analytical Chemistry Institute of Chemistry University of Campinas P.O. Box 6154 13084-971 Campinas SP Brazil
| | - Lauro T. Kubota
- Department of Analytical Chemistry Institute of Chemistry University of Campinas P.O. Box 6154 13084-971 Campinas SP Brazil
| |
Collapse
|
23
|
Polycrystalline boron-doped diamond-based electrochemical biosensor for simultaneous detection of dopamine and melatonin. Anal Chim Acta 2020; 1135:73-82. [PMID: 33070861 DOI: 10.1016/j.aca.2020.08.042] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/21/2020] [Revised: 08/13/2020] [Accepted: 08/22/2020] [Indexed: 11/20/2022]
Abstract
In this study, boron-doped diamond (BDD) electrodes with varied B contents are prepared to determine the feasibility of the direct usage of BDD as an electrochemical biosensor without any modification. The electrochemical performance of the electrodes was investigated through the characterization of electrochemical impedance spectroscopy for potassium ferricyanide/potassium ferrocyanide (K3Fe(CN)6/K4Fe(CN)6) redox couples, as well as through qualitative and quantitative analysis of the two biomolecules dopamine (DA) and melatonin (MLT). The results show that the B content of BDD is the primary parameter for controlling the electrocatalytic current, that is, the response sensitivity. However, the abundant crystal planes and low background current are the key factors in improving the selectivity of the biomarkers to identify multiple analytes. Considering the catalytic current and its ability to distinguish the biomolecules, BDD with a B source carrier gas flow rate of 18 sccm is used as the sensing electrode for the simultaneous detection of DA and MLT. The response peak potential difference reaches 500 mV, and the linear concentration range for the two analytes is 0.4-600 μM, with detection limits of 0.1 μM for DA and 0.003 μM for MLT. These results match those observed for electrochemical sensors modified by various sensitive materials. BDD electrodes show good chemical resistance, good stability, and no pollution and are suitable for long-term usage as biomarker sensors.
Collapse
|
24
|
Chen TW, Tamilalagan E, Chen SM, Akilarasan M, Maheshwaran S, Liu X. An Ultra-Sensitive Electrochemical Sensor for the Detection of Carcinogen Oxidative Stress 4-Nitroquinoline N-Oxide in Biologic Matrices Based on Hierarchical Spinel Structured NiCo 2O 4 and NiCo 2S 4; A Comparative Study. Int J Mol Sci 2020; 21:ijms21093273. [PMID: 32380772 PMCID: PMC7247362 DOI: 10.3390/ijms21093273] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/19/2020] [Revised: 04/27/2020] [Accepted: 04/28/2020] [Indexed: 11/16/2022] Open
Abstract
Various factors leads to cancer; among them oxidative damage is believed to play an important role. Moreover, it is important to identify a method to detect the oxidative damage. Recently, electrochemical sensors have been considered as the one of the most important techniques to detect DNA damage, owing to its rapid detection. However, electrode materials play an important role in the properties of electrochemical sensor. Currently, researchers have aimed to develop novel electrode materials for low-level detection of biomarkers. Herein, we report the facile hydrothermal synthesis of NiCo2O4 micro flowers (MFs) and NiCo2S4 micro spheres (Ms) and evaluate their electrochemical properties for the detection of carcinogen-causing biomarker 4-nitroquinoline n-oxide (4-NQO) in human blood serum and saliva samples. Moreover, as-prepared composites were fabricated on a glass carbon electrode (GCE), and its electrochemical activities for the determination of 4-NQO were investigated by using various electrochemical techniques. Fascinatingly, the NiCo2S4-Ms showed a very low detection limit of 2.29 nM and a wider range of 0.005 to 596.64 µM for detecting 4-NQO. Finally, the practical applicability of NiCo2S4-Ms in the 4-NQO spiked human blood serum and saliva samples were also investigated.
Collapse
Affiliation(s)
- Tse-Wei Chen
- Department of Materials, Imperial College London, London SW7 2AZ, UK;
| | - Elayappan Tamilalagan
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan; (E.T.); (M.A.); (S.M.)
| | - Shen-Ming Chen
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan; (E.T.); (M.A.); (S.M.)
- Correspondence: (S.-M.C.); (X.L.)
| | - Muthumariappan Akilarasan
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan; (E.T.); (M.A.); (S.M.)
| | - Selvarasu Maheshwaran
- Department of Chemical Engineering and Biotechnology, National Taipei University of Technology, Taipei 106, Taiwan; (E.T.); (M.A.); (S.M.)
| | - Xiaoheng Liu
- Key Laboratory of Education Ministry for Soft Chemistry and Functional Materials, Nanjing University of Science and Technology, Nanjing 210094, China
- Correspondence: (S.-M.C.); (X.L.)
| |
Collapse
|
25
|
Gopi PK, Muthukutty B, Chen SM, Chen TW, Liu X, Alothman AA, Ali MA, Wabaidur SM. Platelet-structured strontium titanate perovskite decorated on graphene oxide as a nanocatalyst for electrochemical determination of neurotransmitter dopamine. NEW J CHEM 2020. [DOI: 10.1039/d0nj03564e] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
In this work, we synthesized strontium titanate (SrTiO3) by a simple co-precipitation technique and decorated it with graphene oxide (SrTiO3/GO) for the effective determination of neurotransmitter agent dopamine (DA).
Collapse
Affiliation(s)
- Praveen Kumar Gopi
- Electroanalysis and Bioelectrochemistry Lab
- Department of Chemical Engineering and Biotechnology
- National Taipei University of Technology
- Taipei 106
- Republic of China
| | - Balamurugan Muthukutty
- Electroanalysis and Bioelectrochemistry Lab
- Department of Chemical Engineering and Biotechnology
- National Taipei University of Technology
- Taipei 106
- Republic of China
| | - Shen-Ming Chen
- Electroanalysis and Bioelectrochemistry Lab
- Department of Chemical Engineering and Biotechnology
- National Taipei University of Technology
- Taipei 106
- Republic of China
| | - Tse-Wei Chen
- Electroanalysis and Bioelectrochemistry Lab
- Department of Chemical Engineering and Biotechnology
- National Taipei University of Technology
- Taipei 106
- Republic of China
| | - Xiaoheng Liu
- Key Laboratory of Education Ministry for Soft Chemistry and Functional Materials
- Nanjing University of Science and Technology
- Nanjing 210094
- China
| | - Asma A. Alothman
- Department of Chemistry
- College of Science
- King Saud University
- Riyadh 11451
- Saudi Arabia
| | - Mohammad Ajmal Ali
- Department of Botany and Microbiology
- College of Science
- King Saud University
- Riyadh 11451
- Saudi Arabia
| | | |
Collapse
|