1
|
Amouzad Mahdirajeh T, Mirabi A, Habibi Juybari M, Zafar Mehrabian R, Jalilian HR. Synthesis of the modified SBA-15 mesoporous silica with TAN ligand to preconcentrate and determine trace amounts of Ni (II) ions in water and wastewater samples. Front Chem 2024; 12:1410136. [PMID: 39439932 PMCID: PMC11494652 DOI: 10.3389/fchem.2024.1410136] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2024] [Accepted: 06/17/2024] [Indexed: 10/25/2024] Open
Abstract
The synthesis of modified mesoporous silica (SBA-15), a powerful and highly effective adsorbent, was provided for the preconcentration, extraction, separation, and determination of trace amounts of Ni (II) ions. In this method, SBA-15 modified with 1-(2-thiazolylazo)-2-naphthol (TAN) was used as a suitable absorbent. The absorption of Ni (II) ions was studied using the FAAS technique. Transmission electron microscopy (TEM), thermogravimetric analysis (TGA), Brunauer-Emmett-Teller (BET), energy-dispersive spectroscopy (EDS), Fourier-transform infrared (FT-IR) spectroscopy, and CHNS elemental analysis techniques were used to assess the characteristics of SBA-15 and TAN/SBA-15. Effective parameters (pH, amount of nanocomposite, extraction time, and type of recovery solvent) for extracting Ni (II) ions via TAN/SBA-15 were investigated. The merit figures of the method were obtained with appropriate results, such as detection limit, accuracy, enrichment factor, and preconcentration factor. The calibration curve was linear within the range of 5.0-50 ng mL-1 with a detection limit of 1.8 ng mL-1. High preconcentration, small relative standard deviations, and enrichment factors (approximately 100) were represented by the statistical analysis. The proposed method for measuring Ni (II) ions was used at trace levels in real samples, such as seawater, river water, well water, and wastewater from a textile factory, an electrical power station, an MDF factory, and a food industrial company, with satisfactory results.
Collapse
Affiliation(s)
| | - Ali Mirabi
- Department of Chemistry, Islamic Azad University, Qaemshahr, Iran
| | | | | | | |
Collapse
|
2
|
Dos Santos PM, Zanetti Corazza M, Ricardo Teixeira Tarley C. Synthesis of ionically imprinted Poly(Alylthiourea) in the presence of 1-(2-Pyridylazo)-2-Napthol (PAN) for preconcentration in magnetic dispersive solid phase of nickel ions in water and food samples. Food Chem 2024; 440:138238. [PMID: 38142556 DOI: 10.1016/j.foodchem.2023.138238] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/21/2023] [Revised: 12/04/2023] [Accepted: 12/18/2023] [Indexed: 12/26/2023]
Abstract
In the present study, a magnetic ion-imprinted polymer based on n-allylthiourea in the presence of 1-(2-pyridylazo)-2-naphthol (MIIP-PAN) was synthesized, characterized, and applied in the preconcentration of nickel ions by dispersive magnetic solid phase extraction (DMSPE) with FAAS detection. For comparison, non-imprinted polymer (MNIP-PAN) and imprinted polymer without PAN were synthesized. The characterization of the polymers was performed by FT-IR, DRX, TEM, TGA, VSM, and BET. Selectivity studies were performed comparing the competitive adsorption of Ni2+ with other cations on MIIP-PAN and MNIP-PAN, achieving higher relative selectivity coefficients for MIIP-PAN than for MNIP-PAN and NIP. Under optimized conditions, the method provided a preconcentration factor of 76.70, detection limit of 0.25 µg/L and intra-day (2.06 - 2.33 %) and inter-day (1.82 - 4.90 %) precision. The developed method was applied to samples of water, teas, and chocolate powder, and its precision was evaluated through tests of recovery and analysis of certified materials.
Collapse
Affiliation(s)
- Paula Mantovani Dos Santos
- Departamento de Química, Universidade Estadual de Londrina, Rod. Celso Garcia Cid, PR 445 Km 380, Campus Universitário, Londrina-PR, CEP 86051-990, Brazil
| | - Marcela Zanetti Corazza
- Departamento de Química, Universidade Estadual de Londrina, Rod. Celso Garcia Cid, PR 445 Km 380, Campus Universitário, Londrina-PR, CEP 86051-990, Brazil.
| | - César Ricardo Teixeira Tarley
- Departamento de Química, Universidade Estadual de Londrina, Rod. Celso Garcia Cid, PR 445 Km 380, Campus Universitário, Londrina-PR, CEP 86051-990, Brazil; Instituto Nacional de Ciência e Tecnologia (INCT) de Bioanalítica, Universidade Estadual de Campinas (UNICAMP), Instituto de Química, Departamento de Química Analítica, Cidade Universitária Zeferino Vaz s/n, CEP 13083-970, Campinas SP, Brazil
| |
Collapse
|
3
|
Doğan B, Altunay N. Optimization of [P 6,6,6,14+] 3[GdCl 63-] magnetic ionic liquid assisted dispersive liquid-liquid microextraction for selective and sensitive determination of cadmium in environmental water and food. Food Addit Contam Part A Chem Anal Control Expo Risk Assess 2023; 40:1600-1613. [PMID: 37910078 DOI: 10.1080/19440049.2023.2275601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/24/2023] [Accepted: 10/19/2023] [Indexed: 11/03/2023]
Abstract
A simple and green hydrophobic magnetic ionic-liquid assisted dispersive liquid-liquid microextraction (MIL-DLLME) was optimized for the determination of trace cadmium (Cd (II)) in environmental and food samples by flame atomic absorption spectrophotometer. To achieve selective and sensitive extraction of Cd (II), four MILs were prepared and tested. Extraction parameters of the MIL-DLLME including pH, type and volume of the MIL, type and volume of dispersive solvent, extraction cycle, ionic strength and sample volume were investigated in detail and optimized by Box-Behnken design. Under optimum conditions, matrix effect, recovery study, intra-day and inter-day precision were performed for the MIL-DLLM. The analytical characteristics such as limit of detection, limit of quantification and pre-concentration factor were 0.17, 0.56 and 125 ng mL-1, respectively. The validation of the MIL-DLLME was evaluated by analysis of reference materials. Moreover, the accuracy of the results in the analysis of real samples was evaluated by standard addition and quantitative recoveries (91 ± 5-101 ± 2%) were achieved. The results obtained in the analysis of both reference materials and real samples showed that the MIL-DLLME has a selective applicability for cadmium.
Collapse
Affiliation(s)
- Bünyamin Doğan
- Department of Chemistry, Faculty of Science, Sivas Cumhuriyet University, Sivas, Türkiye
| | - Nail Altunay
- Department of Chemistry, Faculty of Science, Sivas Cumhuriyet University, Sivas, Türkiye
| |
Collapse
|
4
|
Firoozichahak A, Rahmani A, Kazemi M, Rahimpoor R. Magnetic layered double hydroxides for the sensitive dispersive solid phase microextraction of hippuric acid in urine samples prior to HPLC-UV analysis. J Chromatogr B Analyt Technol Biomed Life Sci 2023; 1224:123761. [PMID: 37269707 DOI: 10.1016/j.jchromb.2023.123761] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2023] [Revised: 05/15/2023] [Accepted: 05/16/2023] [Indexed: 06/05/2023]
Abstract
The core- shell structural layered double hydroxide (Fe3O4-SiO2-EN@Zn-Al-LDH) was successfully synthesized and applied as a solid sorbent in the magnetic dispersive micro solid-phase-extraction (M-DµSPE) method. It was combined with high-performance liquid chromatography for the trace analysis of hippuric acid (HA) from urine samples. The obtained magnetic layered double hydroxides (LDHs) were characterized by XRD, FT-IR, VSM, FE-SEM, and BET techniques. The characterization analysis indicated that Fe3O4- SiO2- EN@ Zn-Al-LDH has a sufficient surface area and good saturation magnetism. The affecting variables on the extraction of HA by the proposed method were optimized. Excellent adsorption capacity (127.8 mg g-1), wide linearity dynamic range (0.015-500 µg mL-1), and satisfactory limits of detection and quantification (0.055 and 0.014 µg mL-1, respectively) could be obtained under optimum conditions. The good repeatability and low relative standard deviation (7.2 %), low carry-over (2.7%), good matrix effect (93.6%), high reusability (up to 19 times), and an acceptable percent recovery value (97.2%) proved the selectivity and applicability of the proposed method for the extraction of the trace levels of HA in real urine samples.
Collapse
Affiliation(s)
- Ali Firoozichahak
- Department of Occupational Health Engineering, Faculty of Health, Social Determinants of Health Research Center, Gonabad University of Medical Sciences, Gonabad, Iran
| | - Abdolrasoul Rahmani
- Department of Occupational Health Engineering, Research Center for Health Sciences, School of Health, Larestan University of Medical Sciences, Larestan, Iran
| | - Masoumeh Kazemi
- Department of Occupational Health Engineering, Research Center for Health Sciences, School of Health, Larestan University of Medical Sciences, Larestan, Iran
| | - Razzagh Rahimpoor
- Department of Occupational Health Engineering, Research Center for Health Sciences, School of Health, Larestan University of Medical Sciences, Larestan, Iran.
| |
Collapse
|
5
|
Karababa H, Atasoy M, Yildiz D, Kula İ, Tuzen M. Development of a Sensitive Method for Cadmium Determination in Fish Tissue and Drinking Water Samples by FAAS Using SQT In Situ Atom Trapping. ACS OMEGA 2023; 8:7063-7069. [PMID: 36844526 PMCID: PMC9947951 DOI: 10.1021/acsomega.2c07926] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/13/2022] [Accepted: 01/25/2023] [Indexed: 06/18/2023]
Abstract
A sensitive and robust trap method was developed for the determination of cadmium (Cd) by using a slotted quartz tube. Using this method at a sample suction rate of 7.4 mL/min for 4.0 min collection, a 1467-fold increase in sensitivity was obtained compared to the flame atomic absorption spectrometry method. Under the optimized conditions, a limit of detection of 0.075 ng mL-1 was obtained for the trap method. The interference effects of hydride-forming elements, transition metals, and some anions on the Cd signal were investigated. The developed method was evaluated by analyzing "Sewage Sludge-industrial origin (BCR no: 146R)", "NIST SRM 1640a Trace elements in natural water", and "DOLT: 5 Dogfish Liver". There was a good agreement between the certified and found values at the 95% confidence level. This method was applied successfully for the determination of Cd in drinking water and some fish tissue samples (liver, muscle, and gill) obtained from Muğla province.
Collapse
Affiliation(s)
- Hüseyin Karababa
- Department
of Chemistry, Muğla Sıtkı
Koçman University, Menteşe 48000 Muğla, Turkey
| | - Muhammet Atasoy
- Muğla
Vocational School, Chemistry and Chemical Treatment Technologies Department,
Chemistry Technology Program, Muğla
Sıtkı Koçman University, Menteşe 48000 Muğla, Turkey
| | - Dilek Yildiz
- Environmental
Problems Research and Application Center, Muğla Sıtkı Koçman University, Menteşe 48000 Muğla, Turkey
| | - İbrahim Kula
- Department
of Chemistry, Muğla Sıtkı
Koçman University, Menteşe 48000 Muğla, Turkey
| | - Mustafa Tuzen
- Faculty
of Arts and Sciences, Department of Chemistry, Tokat Gaziosmanpaşa University, 60250 Tokat, Turkey
| |
Collapse
|
6
|
Mahmoudian M, Sarrafi AHM, Konoz E, Niazi A. Magnetic Dispersive Solid‐Phase Extraction Using Toner Powder for Trace Determination of Heavy Metals in Vegetables and Aqueous Media by FAAS: Box‐Behnken Design. ChemistrySelect 2022. [DOI: 10.1002/slct.202203738] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Affiliation(s)
- Masoumeh Mahmoudian
- Department of Chemistry Central Tehran Branch Islamic Azad University Tehran Iran
| | | | - Elaheh Konoz
- Department of Chemistry Central Tehran Branch Islamic Azad University Tehran Iran
| | - Ali Niazi
- Department of Chemistry Central Tehran Branch Islamic Azad University Tehran Iran
| |
Collapse
|
7
|
Baghaei PAM, Mogaddam MRA, Farajzadeh MA, Mohebbi A, Sorouraddin SM. Application of deep eutectic solvent functionalized cobalt ferrite nanoparticles in dispersive micro solid phase extraction of some heavy metals from aqueous samples prior to ICP-OES. J Food Compost Anal 2022. [DOI: 10.1016/j.jfca.2022.105125] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/29/2022]
|
8
|
Mahmoudian M, Sarrafi AHM, Konoz E, Niazi A. Application of DLLME‐SFO as a Green Analytical Tool for Determination of Trace Amounts of Cadmium and Lead in Vegetables and Fruits using FAAS: Optimization Using Box‐Behnken Design**. ChemistrySelect 2022. [DOI: 10.1002/slct.202102488] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Affiliation(s)
- Masoumeh Mahmoudian
- Research Laboratory of Analytical Chemistry Department of Chemistry Faculty of Science Islamic Azad University Central Tehran Branch Tehran Iran
| | - Amir Hossein Mohsen Sarrafi
- Research Laboratory of Analytical Chemistry Department of Chemistry Faculty of Science Islamic Azad University Central Tehran Branch Tehran Iran
| | - Elaheh Konoz
- Research Laboratory of Analytical Chemistry Department of Chemistry Faculty of Science Islamic Azad University Central Tehran Branch Tehran Iran
| | - Ali Niazi
- Research Laboratory of Analytical Chemistry Department of Chemistry Faculty of Science Islamic Azad University Central Tehran Branch Tehran Iran
| |
Collapse
|
9
|
Bozyiğit GD, Kılınç Y, Zaman BT, Chormey DS, Bakırdere S. Polystyrene-coated magnetic nanoparticles based dispersive solid phase extraction for the determination of cadmium in cigarette ash prior to slotted quartz tube flame atomic absorption spectrometry system. ANAL SCI 2022; 38:843-849. [DOI: 10.1007/s44211-022-00104-8] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/28/2021] [Accepted: 02/24/2022] [Indexed: 12/25/2022]
|
10
|
Soylak M, Sevicin AO, Uzcan F. Preconcentration of Nickel by Magnetic Solid-Phase Extraction (MSPE) as the 2-(5-Bromo-2-Pyridylazo)-5-Diethylamino-Phenol (PADAP) Chelate upon Multiwalled Carbon Nanotubes (MWCNTs) with Determination by Flame Atomic Absorption Spectrometry (FAAS). ANAL LETT 2022. [DOI: 10.1080/00032719.2022.2046770] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Mustafa Soylak
- Faculty of Sciences, Department of Chemistry, Erciyes University, Kayseri, Turkey
- Technology Research and Application Center (ERU-TAUM), Erciyes University, Kayseri, Turkey
- Turkish Academy of Sciences (TUBA), Cankaya, Ankara, Turkey
| | - Ali Osman Sevicin
- Faculty of Sciences, Department of Chemistry, Erciyes University, Kayseri, Turkey
- Technology Research and Application Center (ERU-TAUM), Erciyes University, Kayseri, Turkey
| | - Furkan Uzcan
- Faculty of Sciences, Department of Chemistry, Erciyes University, Kayseri, Turkey
- Technology Research and Application Center (ERU-TAUM), Erciyes University, Kayseri, Turkey
| |
Collapse
|
11
|
Şaylan M, Karlıdağ NE, Toprak M, Tekin Z, Balçık U, Öztürk Er E, Bakırdere S. Novel Salicylic Acid Modified Magnetic Nanoparticles Based Ligandless Extraction for the Accurate Determination of Bismuth in Urine Samples by Flame Atomic Absorption Spectrophotometry. ANAL LETT 2022. [DOI: 10.1080/00032719.2021.2023815] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/01/2022]
Affiliation(s)
- Meltem Şaylan
- Department of Chemistry, Yıldız Technical University, İstanbul, Turkey
| | | | - Münevver Toprak
- Department of Chemistry, Yıldız Technical University, İstanbul, Turkey
| | - Zeynep Tekin
- Department of Chemistry, Yıldız Technical University, İstanbul, Turkey
| | - Utku Balçık
- Department of Chemistry, Yıldız Technical University, İstanbul, Turkey
| | - Elif Öztürk Er
- Chemical Engineering Department, Yıldız Technical University, İstanbul, Turkey
| | - Sezgin Bakırdere
- Department of Chemistry, Yıldız Technical University, İstanbul, Turkey
- Turkish Academy of Sciences (TÜBA), Çankaya, Ankara, Turkey
| |
Collapse
|
12
|
Borahan T, Karlıdağ NE, Yağcı Ö, Bakırdere S. Effervescence-assisted liquid phase microextraction prior to slotted quartz tube-flame atomic absorption spectrometry for cadmium determination in domestic wastewater samples. CHEMICAL PAPERS 2021. [DOI: 10.1007/s11696-021-01796-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/01/2022]
|
13
|
Zhang Y, Ning Y, Liao W, Wang W, Wang AJ. Covalent organic framework-LZU1@PEI@Fe 3O 4-based magnetic dispersive micro-solid phase extraction of tetracyclines from environmental water prior to HPLC analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2021; 13:4320-4327. [PMID: 34477188 DOI: 10.1039/d1ay00873k] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
In this work, COF-LZU1@PEI@Fe3O4 was synthesized by immobilization of COF-LZU1 onto the surface of polyethyleneimine-functionalized Fe3O4 nanoparticles (PEI@Fe3O4) and employed as an adsorbent for magnetic dispersive micro-solid phase extraction of tetracyclines (TCs). COF-LZU1@PEI@Fe3O4 was characterized by scanning electron microscopy, Fourier transform infrared spectroscopy, X-ray diffraction and nitrogen adsorption-desorption isotherms analysis. The optimal extraction and desorption conditions were as follows: 15.00 mL sample solution (pH 7.0) extracted with 5.0 mg of adsorbent for 30 min at 30 °C, and then desorbed with 1.50 mL methanol/acetonitrile/0.02 mol L-1 oxalic acid solution (v/v, 1 : 2 : 7). Good linearities were obtained between the peak area and TC concentration ranging from 5-500 μg L-1 with correlation coefficients (R2) higher than 0.9992 and limits of detection lower than 0.51 μg L-1. The relative standard deviations (RSDs) of intra-day and inter-day were less than 5.7% and 7.4%, respectively. The developed method was successfully applied to the determination of TCs in environmental water samples with recoveries in the range of 87.0-113.8% and RSDs less than 5.1%, suggesting great potential of COF-LZU1@PEI@Fe3O4 for efficient extraction and analysis of trace TCs in water samples.
Collapse
Affiliation(s)
- Ying Zhang
- College of Chemistry and Life Sciences, Zhejiang Normal University, Jinhua 321004, China.
| | - Yuhan Ning
- College of Chemistry and Life Sciences, Zhejiang Normal University, Jinhua 321004, China.
| | - Wanliang Liao
- College of Chemistry and Life Sciences, Zhejiang Normal University, Jinhua 321004, China.
| | - Weiping Wang
- College of Chemistry and Life Sciences, Zhejiang Normal University, Jinhua 321004, China.
| | - Ai-Jun Wang
- College of Geography and Environmental Sciences, Zhejiang Normal University, Jinhua 321004, China
| |
Collapse
|
14
|
Borahan T, Karlıdağ NE, Zaman BT, Bakırdere S. A Sensitive Microextraction Method Using Effervescence Tablets to Disperse Fe
3
O
4
Nanoparticles for Cadmium Determination in Lake Water Samples. ChemistrySelect 2021. [DOI: 10.1002/slct.202100405] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
Affiliation(s)
- Tülay Borahan
- Chemistry Department Yıldız Technical University 34210 İstanbul Turkey
| | | | - Buse Tuğba Zaman
- Chemistry Department Yıldız Technical University 34210 İstanbul Turkey
| | - Sezgin Bakırdere
- Chemistry Department Yıldız Technical University 34210 İstanbul Turkey
- Turkish Academy of Sciences (TÜBA) Vedat Dalokay Street, No: 112 06670 Çankaya 06690 Ankara Turkey
| |
Collapse
|
15
|
Altunay N, Hazer B, Tuzen M, Elik A. A new analytical approach for preconcentration, separation and determination of Pb(II) and Cd(II) in real samples using a new adsorbent: Synthesis, characterization and application. Food Chem 2021; 359:129923. [PMID: 33964654 DOI: 10.1016/j.foodchem.2021.129923] [Citation(s) in RCA: 29] [Impact Index Per Article: 7.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2020] [Revised: 04/13/2021] [Accepted: 04/19/2021] [Indexed: 10/21/2022]
Abstract
A green and efficient analytical approach was reported for simultaneous preconcentration, and separation of Pb(II) and Cd(II) in water, vegetables, and barbecue samples by dispersive solid-phase microextraction prior to their determination using flame atomic absorption spectrometry. A new poly-3-hydroxy butyrate-polyvinyl triethyl ammonium chloride comb-type amphiphilic cationic block copolymer (PHBvbNCl) was synthesized and characterized. Main variables such as pH, sorbent amount, adsorption time, eluent type, desorption time, and sample volume were optimized. Detection limits and working ranges for Pb(II) and Cd(II) were 0.03 μg L-1, 0.15 μg L-1, 0.1-250 μg L-1 and 0.5-375 μg L-1, respectively. Enhancement factor for Pb (II) and Cd (II) were 114 and 98. The adsorption capacity of PHBvbNCl for Pb(II) and Cd(II) was 175.2 mg g-1 and 152.9 mg g-1. After the accuracy of the method was confirmed by the analysis of certified reference materials, it was successfully applied to real samples. Finally, the analytical performance of the present method was compared with other methods.
Collapse
Affiliation(s)
- Nail Altunay
- Department of Biochemistry, Sivas Cumhuriyet University, Sivas, Turkey.
| | - Baki Hazer
- Department of Aircraft Airframe Engine Maintenance, Kapadokya University, Nevşehir, Turkey; Zonguldak Bülent Ecevit University, Department of Chemistry, 67100 Zonguldak, Turkey
| | - Mustafa Tuzen
- Department of Chemistry, Tokat Gaziosmanpasa University, Tokat, Turkey; King Fahd University of Petroleum and Minerals, Research Institute, Center for Environment and Water (CEW), Dhahran, 31261 Saudi Arabia
| | - Adil Elik
- Department of Chemistry, Sivas Cumhuriyet University, Sivas, Turkey
| |
Collapse
|
16
|
A selective and sensitive procedure for magnetic solid-phase microextraction of lead(II) on magnetic cellulose nanoparticles from environmental samples prior to its flame atomic absorption spectrometric detection. JOURNAL OF THE IRANIAN CHEMICAL SOCIETY 2020. [DOI: 10.1007/s13738-020-02085-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|