Gao C, Ming Z, Nguyen KL, Pang J, Bedayat A, Dale BM, Zhong X, Finn JP. Ferumoxytol-Enhanced Cardiac Cine MRI Reconstruction Using a Variable-Splitting Spatiotemporal Network. J Magn Reson Imaging 2024. [PMID: 38436994 DOI: 10.1002/jmri.29295] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/26/2023] [Revised: 01/29/2024] [Accepted: 01/31/2024] [Indexed: 03/05/2024] Open
Abstract
BACKGROUND Balanced steady-state free precession (bSSFP) imaging is commonly used in cardiac cine MRI but prone to image artifacts. Ferumoxytol-enhanced (FE) gradient echo (GRE) has been proposed as an alternative. Utilizing the abundance of bSSFP images to develop a computationally efficient network that is applicable to FE GRE cine would benefit future network development. PURPOSE To develop a variable-splitting spatiotemporal network (VSNet) for image reconstruction, trained on bSSFP cine images and applicable to FE GRE cine images. STUDY TYPE Retrospective and prospective. SUBJECTS 41 patients (26 female, 53 ± 19 y/o) for network training, 31 patients (19 female, 49 ± 17 y/o) and 5 healthy subjects (5 female, 30 ± 7 y/o) for testing. FIELD STRENGTH/SEQUENCE 1.5T and 3T, bSSFP and GRE. ASSESSMENT VSNet was compared to VSNet with total variation loss, compressed sensing and low rank methods for 14× accelerated data. The GRAPPA×2/×3 images served as the reference. Peak signal-to-noise-ratio (PSNR), structural similarity index (SSIM), left ventricular (LV) and right ventricular (RV) end-diastolic volume (EDV), end-systolic volume (ESV), and ejection fraction (EF) were measured. Qualitative image ranking and scoring were independently performed by three readers. Latent scores were calculated based on scores of each method relative to the reference. STATISTICS Linear mixed-effects regression, Tukey method, Fleiss' Kappa, Bland-Altman analysis, and Bayesian categorical cumulative probit model. A P-value <0.05 was considered statistically significant. RESULTS VSNet achieved significantly higher PSNR (32.7 ± 0.2), SSIM (0.880 ± 0.004), rank (2.14 ± 0.06), and latent scores (-1.72 ± 0.22) compared to other methods (rank >2.90, latent score < -2.63). Fleiss' Kappa was 0.52 for scoring and 0.61 for ranking. VSNet showed no significantly different LV and RV ESV (P = 0.938) and EF (P = 0.143) measurements, but statistically significant different (2.62 mL) EDV measurements compared to the reference. CONCLUSION VSNet produced the highest image quality and the most accurate functional measurements for FE GRE cine images among the tested 14× accelerated reconstruction methods. LEVEL OF EVIDENCE 3 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Chang Gao
- Department of Physics and Biology in Medicine, University of California Los Angeles, Los Angeles, California, USA
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA
| | - Zhengyang Ming
- Department of Physics and Biology in Medicine, University of California Los Angeles, Los Angeles, California, USA
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA
| | - Kim-Lien Nguyen
- Department of Physics and Biology in Medicine, University of California Los Angeles, Los Angeles, California, USA
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA
- Division of Cardiology, University of California Los Angeles and VA Greater Los Angeles Healthcare System, Los Angeles, California, USA
| | - Jianing Pang
- MR R&D Collaborations, Siemens Medical Solutions USA, Inc., Chicago, Illinois, USA
| | - Arash Bedayat
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA
| | - Brian M Dale
- MR R&D Collaborations, Siemens Medical Solutions USA, Inc., Cary, North Carliona, USA
| | - Xiaodong Zhong
- MR R&D Collaborations, Siemens Medical Solutions USA, Inc., Los Angeles, California, USA
| | - J Paul Finn
- Department of Physics and Biology in Medicine, University of California Los Angeles, Los Angeles, California, USA
- Department of Radiological Sciences, University of California Los Angeles, Los Angeles, California, USA
| |
Collapse
|
2
|
Andrews A, Doctor P, Gaur L, Greil FG, Hussain T, Zou Q. Manifold-based denoising for Ferumoxytol-enhanced 3D cardiac cine MRI. MATHEMATICAL BIOSCIENCES AND ENGINEERING : MBE 2024; 21:3695-3712. [PMID: 38549302 DOI: 10.3934/mbe.2024163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 04/02/2024]
Abstract
The two-dimensional (2D) cine cardiovascular magnetic resonance (CMR) technique is the reference standard for assessing cardiac function. However, one challenge with 2D cine is that the acquisition time for the whole cine stack is long and requires multiple breath holds, which may not be feasible for pediatric or ill patients. Though single breath-hold multi-slice cine may address the issue, it can only acquire low-resolution images, and hence, affect the accuracy of cardiac function assessment. To address these challenges, a Ferumoxytol-enhanced, free breathing, isotropic high-resolution 3D cine technique was developed. The method produces high-contrast cine images with short acquisition times by using compressed sensing together with a manifold-based method for image denoising. This study included fifteen patients (9.1 $ \pm $ 5.6 yrs.) who were referred for clinical cardiovascular magnetic resonance imaging (MRI) with Ferumoxytol contrast and were prescribed the 3D cine sequence. The data was acquired on a 1.5T scanner. Statistical analysis shows that the manifold-based denoised 3D cine can accurately measure ventricular function with no significant differences when compared to the conventional 2D breath-hold (BH) cine. The multiplanar reconstructed images of the proposed 3D cine method are visually comparable to the golden standard 2D BH cine method in terms of clarity, contrast, and anatomical precision. The proposed method eliminated the need for breath holds, reduced scan times, enabled multiplanar reconstruction within an isotropic data set, and has the potential to be used as an effective tool to access cardiovascular conditions.
Collapse
Affiliation(s)
- Anna Andrews
- Department of Biomedical Engineering, Mercer University, Macon, USA
| | - Pezad Doctor
- Division of Pediatric Cardiology, Department of Pediatrics, The University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Lasya Gaur
- Division of Pediatric Cardiology, Department of Pediatrics, The University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - F Gerald Greil
- Division of Pediatric Cardiology, Department of Pediatrics, The University of Texas Southwestern Medical Center, Dallas, TX, USA
- Department of Radiology, The University of Texas Southwestern Medical Center, Dallas, TX, USA
- Advanced Imaging Research Center, The University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Tarique Hussain
- Division of Pediatric Cardiology, Department of Pediatrics, The University of Texas Southwestern Medical Center, Dallas, TX, USA
- Department of Radiology, The University of Texas Southwestern Medical Center, Dallas, TX, USA
- Advanced Imaging Research Center, The University of Texas Southwestern Medical Center, Dallas, TX, USA
| | - Qing Zou
- Division of Pediatric Cardiology, Department of Pediatrics, The University of Texas Southwestern Medical Center, Dallas, TX, USA
- Department of Radiology, The University of Texas Southwestern Medical Center, Dallas, TX, USA
- Advanced Imaging Research Center, The University of Texas Southwestern Medical Center, Dallas, TX, USA
| |
Collapse
|
3
|
Ristow I, Hancken-Pauschinger CV, Zhang S, Stark M, Kaul MG, Rickers C, Herrmann J, Adam G, Bannas P, Well L, Weinrich JM. Non-contrast free-breathing 2D CINE compressed SENSE T1-TFE cardiovascular MRI at 3T in sedated young children for assessment of congenital heart disease. PLoS One 2024; 19:e0297314. [PMID: 38330070 PMCID: PMC10852305 DOI: 10.1371/journal.pone.0297314] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/08/2023] [Accepted: 01/03/2024] [Indexed: 02/10/2024] Open
Abstract
Cardiac MRI is a crucial tool for assessing congenital heart disease (CHD). However, its application remains challenging in young children when performed at 3T. The aim of this retrospective single center study was to compare a non-contrast free-breathing 2D CINE T1-weighted TFE-sequence with compressed sensing (FB 2D CINE CS T1-TFE) with 3D imaging for diagnostic accuracy of CHD, image quality, and vessel diameter measurements in sedated young children. FB 2D CINE CS T1-TFE was compared with a 3D non-contrast whole-heart sequence (3D WH) and 3D contrast-enhanced MR angiography (3D CE-MRA) at 3T in 37 CHD patients (20♂, 1.5±1.4 years). Two radiologists independently assessed image quality, type of CHD, and diagnostic confidence. Diameters and measures of contrast and sharpness of the aorta and pulmonary vessels were determined. A non-parametric multi-factorial approach was used to estimate diagnostic accuracy for the diagnosis of CHD. Linear mixed models were calculated to compare contrast and vessel sharpness. Krippendorff's alpha was determined to quantify vessel diameter agreement. FB 2D CINE CS T1-TFE was rated superior regarding image quality, diagnostic confidence, and diagnostic sensitivity for both intra- and extracardiac pathologies compared to 3D WH and 3D CE-MRA (all p<0.05). FB 2D CINE CS T1-TFE showed superior contrast and vessel sharpness (p<0.001) resulting in the highest proportion of measurable vessels (740/740; 100%), compared to 3D WH (530/620; 85.5%) and 3D CE-MRA (540/560; 96.4%). Regarding vessel diameter measurements, FB 2D CINE CS T1-TFE revealed the closest inter-reader agreement (Krippendorff's alpha: 0.94-0.96; 3D WH: 0.78-0.94; 3D CE-MRA: 0.76-0.93). FB 2D CINE CS T1-TFE demonstrates robustness at 3T and delivers high-quality diagnostic results to assess CHD in sedated young children. Its ability to function without contrast injection and respiratory compensation enhances ease of use and could encourage widespread adoption in clinical practice.
Collapse
Affiliation(s)
- Inka Ristow
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Caroline-Viktoria Hancken-Pauschinger
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Section of Pediatric Radiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Shuo Zhang
- Philips GmbH Market DACH, Hamburg, Germany
| | - Maria Stark
- Institute of Medical Biometry and Epidemiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Michael G. Kaul
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Carsten Rickers
- University Heart Center, Adult Congenital Heart Disease Unit, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Jochen Herrmann
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Section of Pediatric Radiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Gerhard Adam
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Peter Bannas
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Lennart Well
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| | - Julius Matthias Weinrich
- Department of Diagnostic and Interventional Radiology and Nuclear Medicine, Section of Pediatric Radiology, University Medical Center Hamburg-Eppendorf, Hamburg, Germany
| |
Collapse
|
4
|
Murray V, Siddiq S, Crane C, El Homsi M, Kim TH, Wu C, Otazo R. Movienet: Deep space-time-coil reconstruction network without k-space data consistency for fast motion-resolved 4D MRI. Magn Reson Med 2024; 91:600-614. [PMID: 37849064 PMCID: PMC10842259 DOI: 10.1002/mrm.29892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/19/2023] [Revised: 09/27/2023] [Accepted: 09/28/2023] [Indexed: 10/19/2023]
Abstract
PURPOSE To develop a novel deep learning approach for 4D-MRI reconstruction, named Movienet, which exploits space-time-coil correlations and motion preservation instead of k-space data consistency, to accelerate the acquisition of golden-angle radial data and enable subsecond reconstruction times in dynamic MRI. METHODS Movienet uses a U-net architecture with modified residual learning blocks that operate entirely in the image domain to remove aliasing artifacts and reconstruct an unaliased motion-resolved 4D image. Motion preservation is enforced by sorting the input image and reference for training in a linear motion order from expiration to inspiration. The input image was collected with a lower scan time than the reference XD-GRASP image used for training. Movienet is demonstrated for motion-resolved 4D MRI and motion-resistant 3D MRI of abdominal tumors on a therapeutic 1.5T MR-Linac (1.5-fold acquisition acceleration) and diagnostic 3T MRI scanners (2-fold and 2.25-fold acquisition acceleration for 4D and 3D, respectively). Image quality was evaluated quantitatively and qualitatively by expert clinical readers. RESULTS The reconstruction time of Movienet was 0.69 s (4 motion states) and 0.75 s (10 motion states), which is substantially lower than iterative XD-GRASP and unrolled reconstruction networks. Movienet enables faster acquisition than XD-GRASP with similar overall image quality and improved suppression of streaking artifacts. CONCLUSION Movienet accelerates data acquisition with respect to compressed sensing and reconstructs 4D images in less than 1 s, which would enable an efficient implementation of 4D MRI in a clinical setting for fast motion-resistant 3D anatomical imaging or motion-resolved 4D imaging.
Collapse
Affiliation(s)
- Victor Murray
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Syed Siddiq
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Christopher Crane
- Department of Radiation Oncology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Maria El Homsi
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Tae-Hyung Kim
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Can Wu
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| | - Ricardo Otazo
- Department of Medical Physics, Memorial Sloan Kettering Cancer Center, New York, New York, USA
- Department of Radiology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
| |
Collapse
|
5
|
Beetz M, Banerjee A, Ossenberg-Engels J, Grau V. Multi-class point cloud completion networks for 3D cardiac anatomy reconstruction from cine magnetic resonance images. Med Image Anal 2023; 90:102975. [PMID: 37804586 DOI: 10.1016/j.media.2023.102975] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/13/2022] [Revised: 07/08/2023] [Accepted: 09/18/2023] [Indexed: 10/09/2023]
Abstract
Cine magnetic resonance imaging (MRI) is the current gold standard for the assessment of cardiac anatomy and function. However, it typically only acquires a set of two-dimensional (2D) slices of the underlying three-dimensional (3D) anatomy of the heart, thus limiting the understanding and analysis of both healthy and pathological cardiac morphology and physiology. In this paper, we propose a novel fully automatic surface reconstruction pipeline capable of reconstructing multi-class 3D cardiac anatomy meshes from raw cine MRI acquisitions. Its key component is a multi-class point cloud completion network (PCCN) capable of correcting both the sparsity and misalignment issues of the 3D reconstruction task in a unified model. We first evaluate the PCCN on a large synthetic dataset of biventricular anatomies and observe Chamfer distances between reconstructed and gold standard anatomies below or similar to the underlying image resolution for multiple levels of slice misalignment. Furthermore, we find a reduction in reconstruction error compared to a benchmark 3D U-Net by 32% and 24% in terms of Hausdorff distance and mean surface distance, respectively. We then apply the PCCN as part of our automated reconstruction pipeline to 1000 subjects from the UK Biobank study in a cross-domain transfer setting and demonstrate its ability to reconstruct accurate and topologically plausible biventricular heart meshes with clinical metrics comparable to the previous literature. Finally, we investigate the robustness of our proposed approach and observe its capacity to successfully handle multiple common outlier conditions.
Collapse
Affiliation(s)
- Marcel Beetz
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, UK.
| | - Abhirup Banerjee
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, UK; Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford OX3 9DU, UK.
| | - Julius Ossenberg-Engels
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, UK
| | - Vicente Grau
- Institute of Biomedical Engineering, Department of Engineering Science, University of Oxford, Oxford OX3 7DQ, UK
| |
Collapse
|
6
|
Neofytou AP, Neji R, Kowalik GT, Mooiweer R, Wong J, Fotaki A, Ferreira J, Evans C, Bosio F, Mughal N, Razavi R, Pushparajah K, Roujol S. Retrospective motion correction through multi-average k-space data elimination (REMAKE) for free-breathing cardiac cine imaging. Magn Reson Med 2023; 89:2242-2254. [PMID: 36763898 PMCID: PMC10952356 DOI: 10.1002/mrm.29613] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/06/2022] [Revised: 01/06/2023] [Accepted: 01/20/2023] [Indexed: 02/12/2023]
Abstract
PURPOSE To develop a motion-robust reconstruction technique for free-breathing cine imaging with multiple averages. METHOD Retrospective motion correction through multiple average k-space data elimination (REMAKE) was developed using iterative removal of k-space segments (from individual k-space samples) that contribute most to motion corruption while combining any remaining segments across multiple signal averages. A variant of REMAKE, termed REMAKE+, was developed to address any losses in SNR due to k-space information removal. With REMAKE+, multiple reconstructions using different initial conditions were performed, co-registered, and averaged. Both techniques were validated against clinical "standard" signal averaging reconstruction in a static phantom (with simulated motion) and 15 patients undergoing free-breathing cine imaging with multiple averages. Quantitative analysis of myocardial sharpness, blood/myocardial SNR, myocardial-blood contrast-to-noise ratio (CNR), as well as subjective assessment of image quality and rate of diagnostic quality images were performed. RESULTS In phantom, motion artifacts using "standard" (RMS error [RMSE]: 2.2 ± 0.5) were substantially reduced using REMAKE/REMAKE+ (RMSE: 1.5 ± 0.4/1.0 ± 0.4, p < 0.01). In patients, REMAKE/REMAKE+ led to higher myocardial sharpness (0.79 ± 0.09/0.79 ± 0.1 vs. 0.74 ± 0.12 for "standard", p = 0.004/0.04), higher image quality (1.8 ± 0.2/1.9 ± 0.2 vs. 1.6 ± 0.4 for "standard", p = 0.02/0.008), and a higher rate of diagnostic quality images (99%/100% vs. 94% for "standard"). Blood/myocardial SNR for "standard" (94 ± 30/33 ± 10) was higher vs. REMAKE (80 ± 25/28 ± 8, p = 0.002/0.005) and tended to be lower vs. REMAKE+ (105 ± 33/36 ± 12, p = 0.02/0.06). Myocardial-blood CNR for "standard" (61 ± 22) was higher vs. REMAKE (53 ± 19, p = 0.003) and lower vs. REMAKE+ (69 ± 24, p = 0.007). CONCLUSIONS Compared to "standard" signal averaging reconstruction, REMAKE and REMAKE+ provide improved myocardial sharpness, image quality, and rate of diagnostic quality images.
Collapse
Affiliation(s)
- Alexander Paul Neofytou
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and MedicineKing's College LondonLondonUK
| | - Radhouene Neji
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and MedicineKing's College LondonLondonUK
- MR Research CollaborationsSiemens Healthcare LimitedNewton House, Sir William Siemens Square, Frimley, CamberleySurreyUK
| | - Grzegorz Tomasz Kowalik
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and MedicineKing's College LondonLondonUK
| | - Ronald Mooiweer
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and MedicineKing's College LondonLondonUK
- MR Research CollaborationsSiemens Healthcare LimitedNewton House, Sir William Siemens Square, Frimley, CamberleySurreyUK
| | - James Wong
- Department of Paediatric CardiologyEvelina London Children's HospitalLondonUK
| | - Anastasia Fotaki
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and MedicineKing's College LondonLondonUK
| | - Joana Ferreira
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and MedicineKing's College LondonLondonUK
| | - Carl Evans
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and MedicineKing's College LondonLondonUK
| | - Filippo Bosio
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and MedicineKing's College LondonLondonUK
| | - Nabila Mughal
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and MedicineKing's College LondonLondonUK
| | - Reza Razavi
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and MedicineKing's College LondonLondonUK
| | - Kuberan Pushparajah
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and MedicineKing's College LondonLondonUK
- Department of Paediatric CardiologyEvelina London Children's HospitalLondonUK
| | - Sébastien Roujol
- School of Biomedical Engineering and Imaging Sciences, Faculty of Life Sciences and MedicineKing's College LondonLondonUK
| |
Collapse
|
7
|
Cruz G, Hammernik K, Kuestner T, Velasco C, Hua A, Ismail TF, Rueckert D, Botnar RM, Prieto C. Single-heartbeat cardiac cine imaging via jointly regularized nonrigid motion-corrected reconstruction. NMR IN BIOMEDICINE 2023; 36:e4942. [PMID: 36999225 PMCID: PMC10909414 DOI: 10.1002/nbm.4942] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/20/2022] [Revised: 03/07/2023] [Accepted: 03/26/2023] [Indexed: 05/14/2023]
Abstract
The aim of the current study was to develop a novel approach for 2D breath-hold cardiac cine imaging from a single heartbeat, by combining cardiac motion-corrected reconstructions and nonrigidly aligned patch-based regularization. Conventional cardiac cine imaging is obtained via motion-resolved reconstructions of data acquired over multiple heartbeats. Here, we achieve single-heartbeat cine imaging by incorporating nonrigid cardiac motion correction into the reconstruction of each cardiac phase, in conjunction with a motion-aligned patch-based regularization. The proposed Motion-Corrected CINE (MC-CINE) incorporates all acquired data into the reconstruction of each (motion-corrected) cardiac phase, resulting in a better posed problem than motion-resolved approaches. MC-CINE was compared with iterative sensitivity encoding (itSENSE) and Extra-Dimensional Golden Angle Radial Sparse Parallel (XD-GRASP) in 14 healthy subjects in terms of image sharpness, reader scoring (range: 1-5) and reader ranking (range: 1-9) of image quality, and single-slice left ventricular assessment. MC-CINE was significantly superior to both itSENSE and XD-GRASP using 20 heartbeats, two heartbeats, and one heartbeat. Iterative SENSE, XD-GRASP, and MC-CINE achieved a sharpness of 74%, 74%, and 82% using 20 heartbeats, and 53%, 66%, and 82% with one heartbeat, respectively. The corresponding results for reader scoring were 4.0, 4.7, and 4.9 with 20 heartbeats, and 1.1, 3.0, and 3.9 with one heartbeat. The corresponding results for reader ranking were 5.3, 7.3, and 8.6 with 20 heartbeats, and 1.0, 3.2, and 5.4 with one heartbeat. MC-CINE using a single heartbeat presented nonsignificant differences in image quality to itSENSE with 20 heartbeats. MC-CINE and XD-GRASP at one heartbeat both presented a nonsignificant negative bias of less than 2% in ejection fraction relative to the reference itSENSE. It was concluded that the proposed MC-CINE significantly improves image quality relative to itSENSE and XD-GRASP, enabling 2D cine from a single heartbeat.
Collapse
Affiliation(s)
- Gastao Cruz
- School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
| | - Kerstin Hammernik
- Department of ComputingImperial College LondonLondonUK
- Institute for Artificial Intelligence and Informatics in Medicine, Klinikum rechts der IsarTechnical University of MunichMunichGermany
| | - Thomas Kuestner
- School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
- Medical Image and Data Analysis, Department of Diagnostic and Interventional RadiologyUniversity Hospital TübingenTübingenGermany
| | - Carlos Velasco
- School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
| | - Alina Hua
- School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
| | - Tevfik Fehmi Ismail
- School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
| | - Daniel Rueckert
- Department of ComputingImperial College LondonLondonUK
- Institute for Artificial Intelligence and Informatics in Medicine, Klinikum rechts der IsarTechnical University of MunichMunichGermany
| | - Rene Michael Botnar
- School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
- Escuela de IngenieríaPontificia Universidad Católica de ChileSantiagoChile
- Millennium Institute for Intelligent Healthcare EngineeringSantiagoChile
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging SciencesKing's College LondonLondonUK
- Escuela de IngenieríaPontificia Universidad Católica de ChileSantiagoChile
- Millennium Institute for Intelligent Healthcare EngineeringSantiagoChile
| |
Collapse
|
8
|
Eyre K, Lindsay K, Razzaq S, Chetrit M, Friedrich M. Simultaneous multi-parametric acquisition and reconstruction techniques in cardiac magnetic resonance imaging: Basic concepts and status of clinical development. Front Cardiovasc Med 2022; 9:953823. [PMID: 36277755 PMCID: PMC9582154 DOI: 10.3389/fcvm.2022.953823] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2022] [Accepted: 09/22/2022] [Indexed: 11/13/2022] Open
Abstract
Simultaneous multi-parametric acquisition and reconstruction techniques (SMART) are gaining attention for their potential to overcome some of cardiovascular magnetic resonance imaging's (CMR) clinical limitations. The major advantages of SMART lie within their ability to simultaneously capture multiple "features" such as cardiac motion, respiratory motion, T1/T2 relaxation. This review aims to summarize the overarching theory of SMART, describing key concepts that many of these techniques share to produce co-registered, high quality CMR images in less time and with less requirements for specialized personnel. Further, this review provides an overview of the recent developments in the field of SMART by describing how they work, the parameters they can acquire, their status of clinical testing and validation, and by providing examples for how their use can improve the current state of clinical CMR workflows. Many of the SMART are in early phases of development and testing, thus larger scale, controlled trials are needed to evaluate their use in clinical setting and with different cardiac pathologies.
Collapse
Affiliation(s)
- Katerina Eyre
- McGill University Health Centre, Montreal, QC, Canada,Department of Experimental Medicine, McGill University, Montreal, QC, Canada,*Correspondence: Katerina Eyre,
| | - Katherine Lindsay
- McGill University Health Centre, Montreal, QC, Canada,Department of Experimental Medicine, McGill University, Montreal, QC, Canada
| | - Saad Razzaq
- Department of Experimental Medicine, McGill University, Montreal, QC, Canada
| | - Michael Chetrit
- McGill University Health Centre, Montreal, QC, Canada,Department of Experimental Medicine, McGill University, Montreal, QC, Canada
| | - Matthias Friedrich
- McGill University Health Centre, Montreal, QC, Canada,Department of Experimental Medicine, McGill University, Montreal, QC, Canada
| |
Collapse
|
9
|
Weingärtner S, Demirel ÖB, Gama F, Pierce I, Treibel TA, Schulz-Menger J, Akçakaya M. Cardiac phase-resolved late gadolinium enhancement imaging. Front Cardiovasc Med 2022; 9:917180. [PMID: 36247474 PMCID: PMC9557076 DOI: 10.3389/fcvm.2022.917180] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/10/2022] [Accepted: 09/13/2022] [Indexed: 11/25/2022] Open
Abstract
Late gadolinium enhancement (LGE) with cardiac magnetic resonance (CMR) imaging is the clinical reference for assessment of myocardial scar and focal fibrosis. However, current LGE techniques are confined to imaging of a single cardiac phase, which hampers assessment of scar motility and does not allow cross-comparison between multiple phases. In this work, we investigate a three step approach to obtain cardiac phase-resolved LGE images: (1) Acquisition of cardiac phase-resolved imaging data with varying T1 weighting. (2) Generation of semi-quantitative T1* maps for each cardiac phase. (3) Synthetization of LGE contrast to obtain functional LGE images. The proposed method is evaluated in phantom imaging, six healthy subjects at 3T and 20 patients at 1.5T. Phantom imaging at 3T demonstrates consistent contrast throughout the cardiac cycle with a coefficient of variation of 2.55 ± 0.42%. In-vivo results show reliable LGE contrast with thorough suppression of the myocardial tissue is healthy subjects. The contrast between blood and myocardium showed moderate variation throughout the cardiac cycle in healthy subjects (coefficient of variation 18.2 ± 3.51%). Images were acquired at 40–60 ms and 80 ms temporal resolution, at 3T and 1.5, respectively. Functional LGE images acquired in patients with myocardial scar visualized scar tissue throughout the cardiac cycle, albeit at noticeably lower imaging resolution and noise resilience than the reference technique. The proposed technique bears the promise of integrating the advantages of phase-resolved CMR with LGE imaging, but further improvements in the acquisition quality are warranted for clinical use.
Collapse
Affiliation(s)
- Sebastian Weingärtner
- Department of Imaging Physics, Delft University of Technology, Delft, Netherlands
- *Correspondence: Sebastian Weingärtner
| | - Ömer B. Demirel
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, United States
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States
| | - Francisco Gama
- Bart's Heart Centre, St. Bartholomew's Hospital, London, United Kingdom
| | - Iain Pierce
- Bart's Heart Centre, St. Bartholomew's Hospital, London, United Kingdom
| | - Thomas A. Treibel
- Bart's Heart Centre, St. Bartholomew's Hospital, London, United Kingdom
- Institute of Cardiovascular Science, University College London, London, United Kingdom
| | - Jeanette Schulz-Menger
- Working Group on Cardiovascular Magnetic Resonance Imaging, Experimental and Clinical Research Center, Joint Cooperation of the Max-Delbrück-Centrum and Charite-Medical University Berlin, Berlin, Germany
- Department of Cardiology and Nephrology, HELIOS Klinikum Berlin-Buch and DZHK, Berlin, Germany
| | - Mehmet Akçakaya
- Department of Electrical and Computer Engineering, University of Minnesota, Minneapolis, MN, United States
- Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, MN, United States
| |
Collapse
|
10
|
Braunstorfer L, Romanowicz J, Powell AJ, Pattee J, Browne LP, van der Geest RJ, Moghari MH. Non-contrast free-breathing whole-heart 3D cine cardiovascular magnetic resonance with a novel 3D radial leaf trajectory. Magn Reson Imaging 2022; 94:64-72. [PMID: 36122675 DOI: 10.1016/j.mri.2022.09.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/10/2022] [Revised: 08/18/2022] [Accepted: 09/13/2022] [Indexed: 11/25/2022]
Abstract
PURPOSE To develop and validate a non-contrast free-breathing whole-heart 3D cine steady-state free precession (SSFP) sequence with a novel 3D radial leaf trajectory. METHODS We used a respiratory navigator to trigger acquisition of 3D cine data at end-expiration to minimize respiratory motion in our 3D cine SSFP sequence. We developed a novel 3D radial leaf trajectory to reduce gradient jumps and associated eddy-current artifacts. We then reconstructed the 3D cine images with a resolution of 2.0mm3 using an iterative nonlinear optimization algorithm. Prospective validation was performed by comparing ventricular volumetric measurements from a conventional breath-hold 2D cine ventricular short-axis stack against the non-contrast free-breathing whole-heart 3D cine dataset in each patient (n = 13). RESULTS All 3D cine SSFP acquisitions were successful and mean scan time was 07:09 ± 01:31 min. End-diastolic ventricular volumes for left ventricle (LV) and right ventricle (RV) measured from the 3D datasets were smaller than those from 2D (LV: 159.99 ± 42.99 vs. 173.16 ± 47.42; RV: 180.35 ± 46.08 vs. 193.13 ± 49.38; p-value≤0.044; bias<8%), whereas ventricular end-systolic volumes were more comparable (LV: 79.12 ± 26.78 vs. 78.46 ± 25.35; RV: 97.18 ± 32.35 vs. 102.42 ± 32.53; p-value≥0.190, bias<6%). The 3D cine data had a lower subjective image quality score. CONCLUSION Our non-contrast free-breathing whole-heart 3D cine sequence with novel leaf trajectory was robust and yielded smaller ventricular end-diastolic volumes compared to 2D cine imaging. It has the potential to make examinations easier and more comfortable for patients.
Collapse
Affiliation(s)
- Lukas Braunstorfer
- Department of Cardiology, Boston Children's Hospital, Department of Pediatrics, Harvard Medical School, Boston, MA, USA; Department of Informatics, Technical University of Munich, Munich, BY, Germany.
| | - Jennifer Romanowicz
- Department of Cardiology, Boston Children's Hospital, Department of Pediatrics, Harvard Medical School, Boston, MA, USA; Department of Pediatrics, Section of Cardiology, Children's Hospital Colorado, School of Medicine, The University of Colorado, CO, USA
| | - Andrew J Powell
- Department of Cardiology, Boston Children's Hospital, Department of Pediatrics, Harvard Medical School, Boston, MA, USA
| | - Jack Pattee
- Department of Biostatistics and Informatics, Colorado School of Public Health, CO, USA
| | - Lorna P Browne
- Department of Radiology, Children's Hospital Colorado, and School of Medicine, The University of Colorado, CO, USA
| | - Rob J van der Geest
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | - Mehdi H Moghari
- Department of Radiology, Children's Hospital Colorado, and School of Medicine, The University of Colorado, CO, USA
| |
Collapse
|
11
|
Yoshida T, Chen JJ, Zhou B, Finn JP, Hu P, Nguyen KL. Ferumoxytol-enhanced 4D multiphase, steady-state imaging with magnetic resonance in congenital heart disease: ventricular volume and function across 2D and 3D software platforms. Quant Imaging Med Surg 2022; 12:4377-4389. [PMID: 36060580 PMCID: PMC9403575 DOI: 10.21037/qims-21-1243] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 05/07/2022] [Indexed: 11/06/2022]
Abstract
Background Quantitative ventricular volumetry and function are important in the management of congenital heart disease (CHD). Ferumoxytol-enhanced (FE) 4D multiphase, steady state imaging with contrast enhancement (MUSIC) enables high-resolution, 3D cardiac phase-resolved magnetic resonance imaging (MRI) of the beating heart and extracardiac vessels in a single acquisition and without concerns about renal impairment. We aim to evaluate the semi-automatic quantification of ventricular volumetry and function of 4D MUSIC MRI using 2D and 3D software platforms. Methods This HIPAA-compliant and IRB-approved study prospectively recruited 50 children with CHD (3 days to 18 years) who underwent 4D MUSIC MRI at 3.0T between 2013-2017 for clinical indications. Each patient was either intubated in the neonatal intensive care unit (NICU) or underwent general anesthesia at MRI suite. For 2D analysis, we reformatted MUSIC images in Digital Imaging and Communications in Medicine (DICOM) format into ventricular short-axis slices with zero interslice gap. For 3D analysis, we imported DICOMs into a commercially available 3D software platform. Using semi-automatic thresholding, we quantified biventricular volume and ejection fraction (EF). We assessed the bias between MUSIC-derived 2D vs. 3D measurements and correlation between MUSIC vs. conventional 2D balanced steady-state free precession (bSSFP) cine images. We evaluated intra- and inter-observer agreement. Results There was a high degree of correlation between MUSIC-derived volumetric and functional measurements using 2D vs. 3D software (r=0.99, P<0.001). Volumes derived using 3D software platforms were larger than 2D by 0.2 to 2.0 mL/m2 whereas EF measurements were higher by 1.2-3.0%. MUSIC volumetric and functional measures derived from 2D and 3D software platforms corresponded highly with those derived from multi-slice SSFP cine images (r=0.99, P<0.001). The mean difference in volume for reformatted 4D MUSIC relative to bSSFP cine was 1.5 to 3.9 mL/m2. Intra- and inter-observer reliability was excellent. Conclusions Accurate and reliable ventricular volumetry and function can be derived from FE 4D MUSIC MRI studies using commercially available 2D and 3D software platforms. If fully validated in multicenter studies, the FE 4D-MUSIC pulse sequence may supercede conventional multislice 2D cine cardiovascular MRI acquisition protocols for functional evaluation of children with complex CHD.
Collapse
Affiliation(s)
- Takegawa Yoshida
- Diagnostic Cardiovascular Imaging Research Laboratory, David Geffen School of Medicine at University of California, Los Angeles, Los Angeles, CA, USA
| | - Joseph J. Chen
- Diagnostic Cardiovascular Imaging Research Laboratory, David Geffen School of Medicine at University of California, Los Angeles, Los Angeles, CA, USA
- Division of Cardiology, David Geffen School of Medicine at University of California, Los Angeles and Veterans Affairs Greater Los Angeles Healthcare System, Los Angeles, CA, USA
| | - Bill Zhou
- Diagnostic Cardiovascular Imaging Research Laboratory, David Geffen School of Medicine at University of California, Los Angeles, Los Angeles, CA, USA
- Division of Cardiology, David Geffen School of Medicine at University of California, Los Angeles and Veterans Affairs Greater Los Angeles Healthcare System, Los Angeles, CA, USA
| | - J. Paul Finn
- Diagnostic Cardiovascular Imaging Research Laboratory, David Geffen School of Medicine at University of California, Los Angeles, Los Angeles, CA, USA
- Physics and Biology in Medicine Graduate Program at University of California, Los Angeles, CA, USA
| | - Peng Hu
- Diagnostic Cardiovascular Imaging Research Laboratory, David Geffen School of Medicine at University of California, Los Angeles, Los Angeles, CA, USA
- Physics and Biology in Medicine Graduate Program at University of California, Los Angeles, CA, USA
| | - Kim-Lien Nguyen
- Diagnostic Cardiovascular Imaging Research Laboratory, David Geffen School of Medicine at University of California, Los Angeles, Los Angeles, CA, USA
- Division of Cardiology, David Geffen School of Medicine at University of California, Los Angeles and Veterans Affairs Greater Los Angeles Healthcare System, Los Angeles, CA, USA
- Physics and Biology in Medicine Graduate Program at University of California, Los Angeles, CA, USA
| |
Collapse
|
12
|
Ahad J, Cummings E, Franson D, Hamilton J, Seiberlich N. Optimization of through-time radial GRAPPA with coil compression and weight sharing. Magn Reson Med 2022; 88:1244-1254. [PMID: 35426473 PMCID: PMC9246858 DOI: 10.1002/mrm.29258] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2021] [Revised: 02/10/2022] [Accepted: 03/14/2022] [Indexed: 11/16/2022]
Abstract
PURPOSE This work proposes principal component analysis (PCA) coil compression and weight sharing to reduce acquisition and reconstruction time of through-time radial GRAPPA. METHODS Through-time radial GRAPPA enables ungated free-breathing motion-resolved cardiac imaging but requires a long calibration acquisition and GRAPPA weight calculation time. PCA coil compression reduces calibration data requirements and associated acquisition time, and weight sharing reduces the number of unique GRAPPA weight sets and associated weight computation time. In vivo cardiac data reconstructed with coil compression and weight sharing are compared to a gold standard to demonstrate improvement in calibration acquisition and reconstruction performance with minimal loss of image quality. RESULTS Coil compression from 30 physical to 12 virtual coils (90% of signal variance) decreases requisite calibration data by 60%, reducing calibration acquisition time to 6.7 s/slice from 31.5 s/slice reported in original through-time radial GRAPPA work. Resulting images have small increase in RMS error (RMSE). Reconstruction with a weight sharing factor of 8 results in eight-fold reduction in GRAPPA weight calculation time with a comparable RMSE to reconstructions with no weight sharing. Optimized parameters for coil compression and weight sharing applied to reconstructions enables images to be collected with a temporal resolution of 66 ms/frame and spatial resolution of 2.34 × 2.34 mm while reducing calibration acquisition time from 34 to 6.7 s, weight calculation time from 200 to 3 s, and weight application time 18 to 5 s. CONCLUSION Coil compression and weight sharing applied to through-time radial GRAPPA enables fast free-breathing ungated cardiac cine without compromising image quality.
Collapse
Affiliation(s)
- James Ahad
- Department of Biomedical EngineeringCase Western Reserve UniversityClevelandOhioUSA
| | - Evan Cummings
- Department of Biomedical EngineeringUniversity of MichiganAnn ArborMichiganUSA
| | - Dominique Franson
- Department of Biomedical EngineeringCase Western Reserve UniversityClevelandOhioUSA
| | - Jesse Hamilton
- Department of RadiologyUniversity of MichiganAnn ArborMichiganUSA
| | | |
Collapse
|
13
|
Aigner CS, Dietrich S, Schmitter S. Respiration induced B 1 + changes and their impact on universal and tailored 3D kT-point parallel transmission pulses for 7T cardiac imaging. Magn Reson Med 2022; 87:2862-2871. [PMID: 35142400 DOI: 10.1002/mrm.29183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/12/2021] [Revised: 01/11/2022] [Accepted: 01/11/2022] [Indexed: 11/05/2022]
Abstract
PURPOSE Human heart imaging at ultra-high fields is highly challenging because of respiratory motion-induced artefacts and spatially heterogeneous B 1 + profiles. This work demonstrates that respiration resolved 3D B 1 + -maps can be used with a dedicated tailored and universal parallel transmission (pTx) pulse design to compensate respiration related B 1 + changes in subjects performing shallow and deep breathing (SB/DB). METHODS Three-dimensional (3D) B 1 + -maps of the thorax were acquired in 31 subjects under SB and in 15 subjects under SB and DB. Different universal and tailored non-selective pTx pulses were designed from non-respiration resolved (NRR) and respiration resolved (RR) reconstructions of the SB/DB B 1 + -maps. The performance of all pulses was tested with RR-SB/DB B 1 + -maps. Respiration-robust tailored and universal pulses were applied in vivo in 5 subjects at 7T in 3D gradient-echo free-breathing scans. RESULTS All optimized pTx pulses performed well for SB. For DB, however, only the universal and the tailored respiration-robust pulses achieved homogeneous flip angles (FAs) in all subjects and across all respiration states, whereas the tailored respiration-specific pulses resulted in a higher FA variation. The respiration-robust universal pulse resulted in an average coefficient of variation in the FA maps of 12.6% compared to 8.2% achieved by tailored respiration-robust pulses. In vivo measurements at 7T demonstrate the benefits of using respiration-robust pulses for DB. CONCLUSION Universal and tailored respiration-robust pTx pulses based on RR B 1 + -maps are highly preferred to achieve 3D heart FA homogenization at 7T when subjects perform DB, whereas universal and tailored pulses based on NRR B 1 + -maps are sufficient when subjects perform SB.
Collapse
Affiliation(s)
| | | | - Sebastian Schmitter
- Physikalisch-Technische Bundesanstalt, Braunschweig and Berlin, Germany.,Center for Magnetic Resonance Research, University of Minnesota, Minneapolis, Minnesota, USA.,Medical Physics in Radiology, German Cancer Research Center (DKFZ), Heidelberg, Germany
| |
Collapse
|
14
|
Bonanno G, Weiss RG, Piccini D, Yerly J, Soleimani S, Pan L, Bi X, Hays AG, Stuber M, Schär M. Volumetric coronary endothelial function assessment: a feasibility study exploiting stack-of-stars 3D cine MRI and image-based respiratory self-gating. NMR IN BIOMEDICINE 2021; 34:e4589. [PMID: 34291517 PMCID: PMC8969584 DOI: 10.1002/nbm.4589] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/13/2020] [Accepted: 06/25/2021] [Indexed: 06/13/2023]
Abstract
Abnormal coronary endothelial function (CEF), manifesting as depressed vasoreactive responses to endothelial-specific stressors, occurs early in atherosclerosis, independently predicts cardiovascular events, and responds to cardioprotective interventions. CEF is spatially heterogeneous along a coronary artery in patients with atherosclerosis, and thus recently developed and tested non-invasive 2D MRI techniques to measure CEF may not capture the extent of changes in CEF in a given coronary artery. The purpose of this study was to develop and test the first volumetric coronary 3D MRI cine method for assessing CEF along the proximal and mid-coronary arteries with isotropic spatial resolution and in free-breathing. This approach, called 3D-Stars, combines a 6 min continuous, untriggered golden-angle stack-of-stars acquisition with a novel image-based respiratory self-gating method and cardiac and respiratory motion-resolved reconstruction. The proposed respiratory self-gating method agreed well with respiratory bellows and center-of-k-space methods. In healthy subjects, 3D-Stars vessel sharpness was non-significantly different from that by conventional 2D radial in proximal segments, albeit lower in mid-portions. Importantly, 3D-Stars detected normal vasodilatation of the right coronary artery in response to endothelial-dependent isometric handgrip stress in healthy subjects. Coronary artery cross-sectional areas measured using 3D-Stars were similar to those from 2D radial MRI when similar thresholding was used. In conclusion, 3D-Stars offers good image quality and shows feasibility for non-invasively studying vasoreactivity-related lumen area changes along the proximal coronary artery in 3D during free-breathing.
Collapse
Affiliation(s)
- Gabriele Bonanno
- Division of Cardiology, Department of Medicine, Johns Hopkins University, Baltimore, MD, USA
- Russel H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
| | - Robert G. Weiss
- Division of Cardiology, Department of Medicine, Johns Hopkins University, Baltimore, MD, USA
- Russel H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
| | - Davide Piccini
- Advanced Clinical Imaging Technology, Siemens Healthcare, Lausanne, Switzerland
| | - Jérôme Yerly
- Department of Radiology, University Hospital of Lausanne, Lausanne, Switzerland
- Center for Biomedical Imaging (CIBM), University Hospital of Lausanne, Lausanne, Switzerland
| | - Sahar Soleimani
- Russel H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
| | - Li Pan
- Siemens Medical Solutions USA, Inc, Baltimore, MD, USA
| | - Xiaoming Bi
- Siemens Medical Solutions USA, Inc, Los Angeles, CA, USA
| | - Allison G Hays
- Division of Cardiology, Department of Medicine, Johns Hopkins University, Baltimore, MD, USA
| | - Matthias Stuber
- Department of Radiology, University Hospital of Lausanne, Lausanne, Switzerland
- Center for Biomedical Imaging (CIBM), University Hospital of Lausanne, Lausanne, Switzerland
| | - Michael Schär
- Russel H. Morgan Department of Radiology and Radiological Science, Johns Hopkins University, Baltimore, MD, USA
| |
Collapse
|
15
|
Hatipoglu S, Gatehouse P, Krupickova S, Banya W, Daubeney P, Almogheer B, Izgi C, Weale P, Hayes C, Firmin D, Pennell DJ. Reliability of pediatric ventricular function analysis by short-axis "single-cycle-stack-advance" single-shot compressed-sensing cines in minimal breath-hold time. Eur Radiol 2021; 32:2581-2593. [PMID: 34713331 PMCID: PMC8921124 DOI: 10.1007/s00330-021-08335-5] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2021] [Revised: 07/09/2021] [Accepted: 07/23/2021] [Indexed: 12/28/2022]
Abstract
Objectives Cardiovascular magnetic resonance (CMR) cine imaging by compressed sensing (CS) is promising for patients unable to tolerate long breath-holding. However, the need for a steady-state free-precession (SSFP) preparation cardiac cycle for each slice extends the breath-hold duration (e.g. for 10 slices, 20 cardiac cycles) to an impractical length. We investigated a method reducing breath-hold duration by half and assessed its reliability for biventricular volume analysis in a pediatric population. Methods Fifty-five consecutive pediatric patients (median age 12 years, range 7–17) referred for assessment of congenital heart disease or cardiomyopathy were included. Conventional multiple breath-hold SSFP short-axis (SAX) stack cines served as the reference. Real-time CS SSFP cines were applied without the steady-state preparation cycle preceding each SAX cine slice, accepting the limitation of omitting late diastole. The total acquisition time was 1 RR interval/slice. Volumetric analysis was performed for conventional and “single-cycle-stack-advance” (SCSA) cine stacks. Results Bland–Altman analyses [bias (limits of agreement)] showed good agreement in left ventricular (LV) end-diastolic volume (EDV) [3.6 mL (− 5.8, 12.9)], LV end-systolic volume (ESV) [1.3 mL (− 6.0, 8.6)], LV ejection fraction (EF) [0.1% (− 4.9, 5.1)], right ventricular (RV) EDV [3.5 mL (− 3.34, 10.0)], RV ESV [− 0.23 mL (− 7.4, 6.9)], and RV EF [1.70%, (− 3.7, 7.1)] with a trend toward underestimating LV and RV EDVs with the SCSA method. Image quality was comparable for both methods (p = 0.37). Conclusions LV and RV volumetric parameters agreed well between the SCSA and the conventional sequences. The SCSA method halves the breath-hold duration of the commercially available CS sequence and is a reliable alternative for volumetric analysis in a pediatric population. Key Points • Compressed sensing is a promising accelerated cardiovascular magnetic resonance imaging technique. • We omitted the steady-state preparation cardiac cycle preceding each cine slice in compressed sensing and achieved an acquisition speed of 1 RR interval/slice. • This modification called “single-cycle-stack-advance” enabled the acquisition of an entire short-axis cine stack in a single short breath hold. • When tested in a pediatric patient group, the left and right ventricular volumetric parameters agreed well between the “single-cycle-stack-advance” and the conventional sequences.
Collapse
Affiliation(s)
- Suzan Hatipoglu
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, London, UK.
| | - Peter Gatehouse
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, London, UK
| | - Sylvia Krupickova
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, London, UK
| | - Winston Banya
- Research Office, Royal Brompton & Harefield NHS Foundation Trust, London, UK
| | - Piers Daubeney
- Pediatric Cardiology Department, Royal Brompton & Harefield NHS Foundation Trust, London, UK
| | - Batool Almogheer
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, London, UK
| | - Cemil Izgi
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, London, UK
| | | | | | - David Firmin
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, London, UK.,National Heart & Lung Institute, Imperial College, London, UK
| | - Dudley J Pennell
- Cardiovascular Magnetic Resonance Unit, Royal Brompton & Harefield NHS Foundation Trust, London, UK.,National Heart & Lung Institute, Imperial College, London, UK
| |
Collapse
|
16
|
Godino-Moya A, Menchón-Lara RM, Martín-Fernández M, Prieto C, Alberola-López C. Elastic AlignedSENSE for Dynamic MR Reconstruction: A Proof of Concept in Cardiac Cine. ENTROPY 2021; 23:e23050555. [PMID: 33947089 PMCID: PMC8145958 DOI: 10.3390/e23050555] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/29/2021] [Revised: 04/26/2021] [Accepted: 04/27/2021] [Indexed: 11/25/2022]
Abstract
Numerous methods in the extensive literature on magnetic resonance imaging (MRI) reconstruction exploit temporal redundancy to accelerate cardiac cine. Some of them include motion compensation, which involves high computational costs and long runtimes. In this work, we proposed a method—elastic alignedSENSE (EAS)—for the direct reconstruction of a motion-free image plus a set of nonrigid deformations to reconstruct a 2D cardiac sequence. The feasibility of the proposed approach was tested in 2D Cartesian and golden radial multi-coil breath-hold cardiac cine acquisitions. The proposed approach was compared against parallel imaging compressed sense (sPICS) and group-wise motion corrected compressed sense (GWCS) reconstructions. EAS provides better results on objective measures with considerable less runtime when an acceleration factor is higher than 10×. Subjective assessment of an expert, however, invited proposing the combination of EAS and GWCS as a preferable alternative to GWCS or EAS in isolation.
Collapse
Affiliation(s)
- Alejandro Godino-Moya
- Laboratorio de Procesado de Imagen, E.T.S.I. Telecomunicación, Universidad de Valladolid, Paseo Belén 15, 47011 Valladolid, Spain; (R.-M.M.-L.); (M.M.-F.); (C.A.-L.)
- Correspondence:
| | - Rosa-María Menchón-Lara
- Laboratorio de Procesado de Imagen, E.T.S.I. Telecomunicación, Universidad de Valladolid, Paseo Belén 15, 47011 Valladolid, Spain; (R.-M.M.-L.); (M.M.-F.); (C.A.-L.)
| | - Marcos Martín-Fernández
- Laboratorio de Procesado de Imagen, E.T.S.I. Telecomunicación, Universidad de Valladolid, Paseo Belén 15, 47011 Valladolid, Spain; (R.-M.M.-L.); (M.M.-F.); (C.A.-L.)
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King’s College London, London SE1 7EH, UK;
- School of Engineering, Pontificia Universidad Catolica de Chile, Santiago 4860, Chile
| | - Carlos Alberola-López
- Laboratorio de Procesado de Imagen, E.T.S.I. Telecomunicación, Universidad de Valladolid, Paseo Belén 15, 47011 Valladolid, Spain; (R.-M.M.-L.); (M.M.-F.); (C.A.-L.)
| |
Collapse
|
17
|
Nguyen KL, Ghosh RM, Griffin LM, Yoshida T, Bedayat A, Rigsby CK, Fogel MA, Whitehead KK, Hu P, Finn JP. Four-dimensional Multiphase Steady-State MRI with Ferumoxytol Enhancement: Early Multicenter Feasibility in Pediatric Congenital Heart Disease. Radiology 2021; 300:162-173. [PMID: 33876971 DOI: 10.1148/radiol.2021203696] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Background The value of MRI in pediatric congenital heart disease (CHD) is well recognized; however, the requirement for expert oversight impedes its widespread use. Four-dimensional (4D) multiphase steady-state imaging with contrast enhancement (MUSIC) is a cardiovascular MRI technique that uses ferumoxytol and captures all anatomic features dynamically. Purpose To evaluate multicenter feasibility of 4D MUSIC MRI in pediatric CHD. Materials and Methods In this prospective study, participants with CHD underwent 4D MUSIC MRI at 3.0 T or 1.5 T between 2014 and 2020. From a pool of 460 total studies, an equal number of MRI studies from three sites (n = 60) was chosen for detailed analysis. With use of a five-point scale, the feasibility of 4D MUSIC was scored on the basis of artifacts, image quality, and diagnostic confidence for intracardiac and vascular connections (n = 780). Respiratory motion suppression was assessed by using the signal intensity profile. Bias between 4D MUSIC and two-dimensional (2D) cine imaging was evaluated by using Bland-Altman analysis; 4D MUSIC examination duration was compared with that of the local standard for CHD. Results A total of 206 participants with CHD underwent MRI at 3.0 T, and 254 participants underwent MRI at 1.5 T. Of the 60 MRI examinations chosen for analysis (20 per site; median participant age, 14.4 months [interquartile range, 2.3-49 months]; 33 female participants), 56 (93%) had good or excellent image quality scores across a spectrum of disease complexity (mean score ± standard deviation: 4.3 ± 0.6 for site 1, 4.9 ± 0.3 for site 2, and 4.6 ± 0.7 for site 3; P < .001). Artifact scores were inversely related to image quality (r = -0.88, P < .001) and respiratory motion suppression (P < .001, r = -0.45). Diagnostic confidence was high or definite in 730 of 780 (94%) intracardiac and vascular connections. The correlation between 4D MUSIC and 2D cine ventricular volumes and ejection fraction was high (range of r = 0.72-0.85; P < .001 for all). Compared with local standard MRI, 4D MUSIC reduced the image acquisition time (44 minutes ± 20 vs 12 minutes ± 3, respectively; P < .001). Conclusion Four-dimensional multiphase steady-state imaging with contrast enhancement MRI in pediatric congenital heart disease was feasible in a multicenter setting, shortened the examination time, and simplified the acquisition protocol, independently of disease complexity. Clinical trial registration no. NCT02752191 © RSNA, 2021 Online supplemental material is available for this article. See also the editorial by Roest and Lamb in this issue.
Collapse
Affiliation(s)
- Kim-Lien Nguyen
- From the Diagnostic Cardiovascular Imaging Laboratory, Department of Radiological Sciences (K.L.N., T.Y., A.B., P.H., J.P.F.), and Division of Cardiology (K.L.N.), David Geffen School of Medicine at UCLA, 300 Medical Plaza, B119, Los Angeles, CA 90095; VA Greater Los Angeles Healthcare System, Los Angeles, Calif (K.L.N.); Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa (R.M.G., M.A.F., K.K.W.); Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital, Chicago, Ill (L.M.G., C.K.R.); and Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Ill (L.M.G., C.K.R.)
| | - Reena M Ghosh
- From the Diagnostic Cardiovascular Imaging Laboratory, Department of Radiological Sciences (K.L.N., T.Y., A.B., P.H., J.P.F.), and Division of Cardiology (K.L.N.), David Geffen School of Medicine at UCLA, 300 Medical Plaza, B119, Los Angeles, CA 90095; VA Greater Los Angeles Healthcare System, Los Angeles, Calif (K.L.N.); Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa (R.M.G., M.A.F., K.K.W.); Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital, Chicago, Ill (L.M.G., C.K.R.); and Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Ill (L.M.G., C.K.R.)
| | - Lindsay M Griffin
- From the Diagnostic Cardiovascular Imaging Laboratory, Department of Radiological Sciences (K.L.N., T.Y., A.B., P.H., J.P.F.), and Division of Cardiology (K.L.N.), David Geffen School of Medicine at UCLA, 300 Medical Plaza, B119, Los Angeles, CA 90095; VA Greater Los Angeles Healthcare System, Los Angeles, Calif (K.L.N.); Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa (R.M.G., M.A.F., K.K.W.); Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital, Chicago, Ill (L.M.G., C.K.R.); and Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Ill (L.M.G., C.K.R.)
| | - Takegawa Yoshida
- From the Diagnostic Cardiovascular Imaging Laboratory, Department of Radiological Sciences (K.L.N., T.Y., A.B., P.H., J.P.F.), and Division of Cardiology (K.L.N.), David Geffen School of Medicine at UCLA, 300 Medical Plaza, B119, Los Angeles, CA 90095; VA Greater Los Angeles Healthcare System, Los Angeles, Calif (K.L.N.); Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa (R.M.G., M.A.F., K.K.W.); Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital, Chicago, Ill (L.M.G., C.K.R.); and Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Ill (L.M.G., C.K.R.)
| | - Arash Bedayat
- From the Diagnostic Cardiovascular Imaging Laboratory, Department of Radiological Sciences (K.L.N., T.Y., A.B., P.H., J.P.F.), and Division of Cardiology (K.L.N.), David Geffen School of Medicine at UCLA, 300 Medical Plaza, B119, Los Angeles, CA 90095; VA Greater Los Angeles Healthcare System, Los Angeles, Calif (K.L.N.); Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa (R.M.G., M.A.F., K.K.W.); Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital, Chicago, Ill (L.M.G., C.K.R.); and Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Ill (L.M.G., C.K.R.)
| | - Cynthia K Rigsby
- From the Diagnostic Cardiovascular Imaging Laboratory, Department of Radiological Sciences (K.L.N., T.Y., A.B., P.H., J.P.F.), and Division of Cardiology (K.L.N.), David Geffen School of Medicine at UCLA, 300 Medical Plaza, B119, Los Angeles, CA 90095; VA Greater Los Angeles Healthcare System, Los Angeles, Calif (K.L.N.); Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa (R.M.G., M.A.F., K.K.W.); Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital, Chicago, Ill (L.M.G., C.K.R.); and Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Ill (L.M.G., C.K.R.)
| | - Mark A Fogel
- From the Diagnostic Cardiovascular Imaging Laboratory, Department of Radiological Sciences (K.L.N., T.Y., A.B., P.H., J.P.F.), and Division of Cardiology (K.L.N.), David Geffen School of Medicine at UCLA, 300 Medical Plaza, B119, Los Angeles, CA 90095; VA Greater Los Angeles Healthcare System, Los Angeles, Calif (K.L.N.); Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa (R.M.G., M.A.F., K.K.W.); Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital, Chicago, Ill (L.M.G., C.K.R.); and Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Ill (L.M.G., C.K.R.)
| | - Kevin K Whitehead
- From the Diagnostic Cardiovascular Imaging Laboratory, Department of Radiological Sciences (K.L.N., T.Y., A.B., P.H., J.P.F.), and Division of Cardiology (K.L.N.), David Geffen School of Medicine at UCLA, 300 Medical Plaza, B119, Los Angeles, CA 90095; VA Greater Los Angeles Healthcare System, Los Angeles, Calif (K.L.N.); Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa (R.M.G., M.A.F., K.K.W.); Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital, Chicago, Ill (L.M.G., C.K.R.); and Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Ill (L.M.G., C.K.R.)
| | - Peng Hu
- From the Diagnostic Cardiovascular Imaging Laboratory, Department of Radiological Sciences (K.L.N., T.Y., A.B., P.H., J.P.F.), and Division of Cardiology (K.L.N.), David Geffen School of Medicine at UCLA, 300 Medical Plaza, B119, Los Angeles, CA 90095; VA Greater Los Angeles Healthcare System, Los Angeles, Calif (K.L.N.); Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa (R.M.G., M.A.F., K.K.W.); Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital, Chicago, Ill (L.M.G., C.K.R.); and Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Ill (L.M.G., C.K.R.)
| | - J Paul Finn
- From the Diagnostic Cardiovascular Imaging Laboratory, Department of Radiological Sciences (K.L.N., T.Y., A.B., P.H., J.P.F.), and Division of Cardiology (K.L.N.), David Geffen School of Medicine at UCLA, 300 Medical Plaza, B119, Los Angeles, CA 90095; VA Greater Los Angeles Healthcare System, Los Angeles, Calif (K.L.N.); Division of Cardiology, Children's Hospital of Philadelphia, Philadelphia, Pa (R.M.G., M.A.F., K.K.W.); Department of Medical Imaging, Ann & Robert H. Lurie Children's Hospital, Chicago, Ill (L.M.G., C.K.R.); and Department of Radiology, Northwestern University Feinberg School of Medicine, Chicago, Ill (L.M.G., C.K.R.)
| |
Collapse
|
18
|
Küstner T, Bustin A, Jaubert O, Hajhosseiny R, Masci PG, Neji R, Botnar R, Prieto C. Fully self-gated free-running 3D Cartesian cardiac CINE with isotropic whole-heart coverage in less than 2 min. NMR IN BIOMEDICINE 2021; 34:e4409. [PMID: 32974984 DOI: 10.1002/nbm.4409] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/24/2020] [Revised: 08/19/2020] [Accepted: 08/21/2020] [Indexed: 06/11/2023]
Abstract
PURPOSE To develop a novel fast water-selective free-breathing 3D Cartesian cardiac CINE scan with full self-navigation and isotropic whole-heart (WH) coverage. METHODS A free-breathing 3D Cartesian cardiac CINE scan with a water-selective balanced steady-state free precession and a continuous (non-ECG-gated) variable-density Cartesian sampling with spiral profile ordering, out-inward sampling and acquisition-adaptive alternating tiny golden and golden angle increment between spiral arms is proposed. Data is retrospectively binned based on respiratory and cardiac self-navigation signals. A translational respiratory-motion-corrected and cardiac-motion-resolved image is reconstructed with a multi-bin patch-based low-rank reconstruction (MB-PROST) within about 15 min. A respiratory-motion-resolved approach is also investigated. The proposed 3D Cartesian cardiac CINE is acquired in sagittal orientation in 1 min 50 s for 1.9 mm3 isotropic WH coverage. Left ventricular (LV) function parameters and image quality derived from a blinded reading of the proposed 3D CINE framework are compared against conventional multi-slice 2D CINE imaging in 10 healthy subjects and 10 patients with suspected cardiovascular disease. RESULTS The proposed framework provides free-breathing 3D cardiac CINE images with 1.9 mm3 spatial and about 45 ms temporal resolution in a short acquisition time (<2 min). LV function parameters derived from 3D CINE were in good agreement with 2D CINE (10 healthy subjects and 10 patients). Bias and confidence intervals were obtained for end-systolic volume, end-diastolic volume and ejection fraction of 0.1 ± 3.5 mL, -0.6 ± 8.2 mL and -0.1 ± 2.2%, respectively. CONCLUSION The proposed framework enables isotropic 3D Cartesian cardiac CINE under free breathing for fast assessment of cardiac anatomy and function.
Collapse
Affiliation(s)
- Thomas Küstner
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
| | - Aurelien Bustin
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
| | - Olivier Jaubert
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
| | - Reza Hajhosseiny
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
| | - Pier Giorgio Masci
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
| | - Radhouene Neji
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
- MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK
| | - René Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
19
|
Abstract
Classification of heart failure is based on the left ventricular ejection fraction (EF): preserved EF, midrange EF, and reduced EF. There remains an unmet need for further heart failure phenotyping of ventricular structure-function relationships. Because of high spatiotemporal resolution, cardiac magnetic resonance (CMR) remains the reference modality for quantification of ventricular contractile function. The authors aim to highlight novel frameworks, including theranostic use of ferumoxytol, to enable more efficient evaluation of ventricular function in heart failure patients who are also frequently anemic, and to discuss emerging quantitative CMR approaches for evaluation of ventricular structure-function relationships in heart failure.
Collapse
|
20
|
Moghari MH, van der Geest RJ, Brighenti M, Powell AJ. Cardiac magnetic resonance using fused 3D cine and 4D flow sequences:Validation of ventricular and blood flow measurements. Magn Reson Imaging 2020; 74:203-212. [PMID: 33035637 DOI: 10.1016/j.mri.2020.09.026] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/16/2020] [Revised: 08/31/2020] [Accepted: 09/27/2020] [Indexed: 10/23/2022]
Abstract
PURPOSE Current cardiovascular magnetic resonance (CMR) examinations require expert planning, multiple breath holds, and 2D imaging. To address this, we sought to develop and validate a comprehensive free-breathing 3D cine function and flow CMR examination using a steady-state free precession (SSFP) sequence to depict anatomy fused with a spatially registered phase contrast (PC) sequence for blood flow analysis. METHODS In a prospective study, 25 patients underwent a CMR examination which included a 3D cine SSFP sequence and a 3D cine PC (also known as 4D flow) sequence acquired during free-breathing and after the administration of a gadolinium-based contrast agent. Both 3D sequences covered the heart and mediastinum, and used retrospective vectorcardiogram gating (20 phases/beat interpolated to 30 phases/beat) and prospective respiratory motion compensation confining data acquisition to end-expiration. Cardiovascular measurements derived from the 3D cine SSFP and PC images were then compared with those from standard 2D imaging. RESULTS All 3D cine SSFP and PC acquisitions were completed successfully. The mean time for the 3D cine sequences including prescription was shorter than that for the corresponding 2D sequences (21 min vs. 36 min, P-value <0.001). Left and right ventricular end-diastolic volumes and stroke volumes by 3D cine SSFP were slightly smaller than those from 2D cine SSFP (all biases ≤5%). The blood flow measurements from the 3D and 2D sequences had close agreement in the ascending aorta (bias -2.6%) but main pulmonary artery flow was lower with the 3D cine sequence (bias -11.2%). CONCLUSION Compared to the conventional 2D cine approach, a comprehensive 3D cine function and flow examination was faster and yielded slightly lower left and right end-diastolic volumes, stroke volumes, and main pulmonary artery blood flow. This free-breathing 3D cine approach allows flexible post-examination data analysis and has the potential to make examinations more comfortable for patients and easier to perform for the operator.
Collapse
Affiliation(s)
- Mehdi H Moghari
- Department of Cardiology, Boston Children's Hospital, Boston, MA, USA; Department of Pediatrics, Harvard Medical School, Boston, MA, USA.
| | - Rob J van der Geest
- Department of Radiology, Leiden University Medical Center, Leiden, the Netherlands
| | | | - Andrew J Powell
- Department of Cardiology, Boston Children's Hospital, Boston, MA, USA; Department of Pediatrics, Harvard Medical School, Boston, MA, USA
| |
Collapse
|
21
|
Krishnamoorthy G, Smink J, Tourais J, Breeuwer M, Kouwenhoven M. Variable anisotropic FOV for 3D radial imaging with spiral phyllotaxis (VASP). Magn Reson Med 2020; 85:68-77. [PMID: 32851711 PMCID: PMC7692914 DOI: 10.1002/mrm.28449] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2019] [Revised: 05/30/2020] [Accepted: 07/08/2020] [Indexed: 12/16/2022]
Abstract
PURPOSE To develop a new 3D radial trajectory based on the natural spiral phyllotaxis (SP), with variable anisotropic FOV. THEORY & METHODS A 3D radial trajectory based on the SP with favorable interleaving properties for cardiac imaging has been proposed by Piccini et al (Magn Reson Med. 2011;66:1049-1056), which supports a FOV with a fixed anisotropy. However, a fixed anisotropy can be inefficient when sampling objects with different anisotropic dimensions. We extend Larson's 3D radial method to provide variable anisotropic FOV for spiral phyllotaxis (VASP). Simulations were performed to measure distance between successive projections, analyze point spread functions, and compare aliasing artifacts for both VASP and conventional SP. VASP was fully implemented on a whole-body clinical MR scanner. Phantom and in vivo cardiac images were acquired at 1.5 tesla. RESULTS Simulations, phantom, and in vivo experiments confirmed that VASP can achieve variable anisotropic FOV while maintaining the favorable interleaving properties of SP. For an anisotropic FOV with 100:100:35 ratio, VASP required ~65% fewer radial projections than the conventional SP to satisfy Nyquist criteria. Alternatively, when the same number of radial projections were used as in conventional SP, VASP produced fewer aliasing artifacts for anisotropic objects within the excited imaging volumes. CONCLUSION We have developed a new method (VASP), which enables variable anisotropic FOV for 3D radial trajectory with SP. For anisotropic objects within the excited imaging volumes, VASP can reduce scan times and/or reduce aliasing artifacts.
Collapse
Affiliation(s)
- Guruprasad Krishnamoorthy
- Department of MR R&D-Clinical Science, Philips, Best, The Netherlands.,Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Jouke Smink
- Department of MR R&D-Clinical Science, Philips, Best, The Netherlands
| | - Joao Tourais
- Department of MR R&D-Clinical Science, Philips, Best, The Netherlands.,Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Marcel Breeuwer
- Department of MR R&D-Clinical Science, Philips, Best, The Netherlands.,Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, The Netherlands
| | - Marc Kouwenhoven
- Department of MR R&D-Clinical Science, Philips, Best, The Netherlands
| |
Collapse
|
22
|
Küstner T, Fuin N, Hammernik K, Bustin A, Qi H, Hajhosseiny R, Masci PG, Neji R, Rueckert D, Botnar RM, Prieto C. CINENet: deep learning-based 3D cardiac CINE MRI reconstruction with multi-coil complex-valued 4D spatio-temporal convolutions. Sci Rep 2020; 10:13710. [PMID: 32792507 PMCID: PMC7426830 DOI: 10.1038/s41598-020-70551-8] [Citation(s) in RCA: 92] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2020] [Accepted: 07/31/2020] [Indexed: 11/29/2022] Open
Abstract
Cardiac CINE magnetic resonance imaging is the gold-standard for the assessment of cardiac function. Imaging accelerations have shown to enable 3D CINE with left ventricular (LV) coverage in a single breath-hold. However, 3D imaging remains limited to anisotropic resolution and long reconstruction times. Recently deep learning has shown promising results for computationally efficient reconstructions of highly accelerated 2D CINE imaging. In this work, we propose a novel 4D (3D + time) deep learning-based reconstruction network, termed 4D CINENet, for prospectively undersampled 3D Cartesian CINE imaging. CINENet is based on (3 + 1)D complex-valued spatio-temporal convolutions and multi-coil data processing. We trained and evaluated the proposed CINENet on in-house acquired 3D CINE data of 20 healthy subjects and 15 patients with suspected cardiovascular disease. The proposed CINENet network outperforms iterative reconstructions in visual image quality and contrast (+ 67% improvement). We found good agreement in LV function (bias ± 95% confidence) in terms of end-systolic volume (0 ± 3.3 ml), end-diastolic volume (− 0.4 ± 2.0 ml) and ejection fraction (0.1 ± 3.2%) compared to clinical gold-standard 2D CINE, enabling single breath-hold isotropic 3D CINE in less than 10 s scan and ~ 5 s reconstruction time.
Collapse
Affiliation(s)
- Thomas Küstner
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, Lambeth Wing, London, UK.
| | - Niccolo Fuin
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, Lambeth Wing, London, UK
| | | | - Aurelien Bustin
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, Lambeth Wing, London, UK
| | - Haikun Qi
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, Lambeth Wing, London, UK
| | - Reza Hajhosseiny
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, Lambeth Wing, London, UK
| | - Pier Giorgio Masci
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, Lambeth Wing, London, UK
| | - Radhouene Neji
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, Lambeth Wing, London, UK.,MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK
| | - Daniel Rueckert
- Department of Computing, Imperial College London, London, UK
| | - René M Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, Lambeth Wing, London, UK.,Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, Lambeth Wing, London, UK.,Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
23
|
Henningsson M, Brundin M, Scheffel T, Edin C, Viola F, Carlhäll CJ. Quantification of epicardial fat using 3D cine Dixon MRI. BMC Med Imaging 2020; 20:80. [PMID: 32664848 PMCID: PMC7362508 DOI: 10.1186/s12880-020-00478-z] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2020] [Accepted: 07/02/2020] [Indexed: 11/10/2022] Open
Abstract
Background There is an increased interest in quantifying and characterizing epicardial fat which has been linked to various cardiovascular diseases such as coronary artery disease and atrial fibrillation. Recently, three-dimensional single-phase Dixon techniques have been used to depict the heart and to quantify the surrounding fat. The purpose of this study was to investigate the merits of a new high-resolution cine 3D Dixon technique for quantification of epicardial adipose tissue and compare it to single-phase 3D Dixon in patients with cardiovascular disease. Methods Fifteen patients referred for clinical CMR examination of known or suspected heart disease were scanned on a 1.5 T scanner using single-phase Dixon and cine Dixon. Epicardial fat was segmented by three readers and intra- and inter-observer variability was calculated per slice. Cine Dixon segmentation was performed in the same cardiac phase as single-phase Dixon. Subjective image quality assessment of water and fat images were performed by three readers using a 4-point Likert scale (1 = severe; 2 = significant; 3 = mild; 4 = no blurring of cardiac structures). Results Intra-observer variability was excellent for cine Dixon images (ICC = 0.96), and higher than single-phase Dixon (ICC = 0.92). Inter-observer variability was good for cine Dixon (ICC = 0.76) and moderate for single-phase Dixon (ICC = 0.63). The intra-observer measurement error (mean ± standard deviation) per slice for cine was − 0.02 ± 0.51 ml (− 0.08 ± 0.4%), and for single-phase 0.39 ± 0.72 ml (0.18 ± 0.41%). Inter-observer measurement error for cine was 0.46 ± 0.98 ml (0.11 ± 0.46%) and for single-phase 0.42 ± 1.53 ml (0.17 ± 0.47%). Visual scoring of the water image yielded median of 2 (interquartile range = [Q3-Q1] 2–2) for cine and median of 3 (interquartile range = 3–2) for single-phase (P < 0.05) while no significant difference was found for the fat images, both techniques yielding a median of 3 and interquartile range of 3–2. Conclusion Cine Dixon can be used to quantify epicardial fat with lower intra- and inter-observer variability compared to standard single-phase Dixon. The time-resolved information provided by the cine acquisition appears to support the delineation of the epicardial adipose tissue depot.
Collapse
Affiliation(s)
- Markus Henningsson
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden. .,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden. .,School of Biomedical Engineering and Imaging Sciences, King's College London, London, UK.
| | - Martin Brundin
- Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Tobias Scheffel
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Carl Edin
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| | - Federica Viola
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
| | - Carl-Johan Carlhäll
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden.,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden.,Department of Clinical Physiology, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
24
|
Montalt-Tordera J, Kowalik G, Gotschy A, Steeden J, Muthurangu V. Rapid 3D whole-heart cine imaging using golden ratio stack of spirals. Magn Reson Imaging 2020; 72:1-7. [PMID: 32562742 DOI: 10.1016/j.mri.2020.06.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/23/2020] [Revised: 05/14/2020] [Accepted: 06/11/2020] [Indexed: 11/16/2022]
Abstract
Three-dimensional cine imaging provides a wealth of information about cardiac anatomy and function, but its use in the clinical environment is limited because data acquisition is very time consuming. In this work, a free-breathing 3D whole-heart cine imaging framework was developed using a time-efficient stack of spirals trajectory and accelerated reconstruction. Two suitable view ordering methods are considered with different spacing between k-space readouts in the partition dimension: uniform and tiny golden ratio based. A simulation study suggested the latter did not present any benefits in terms of similarity to the true image. The proposed method was subsequently tested on 10 prospective subjects and compared with conventional multi-slice breath-hold imaging. Image quality was evaluated using objective and subjective scores and ventricular measurements were compared to assess clinical accuracy. Image quality was lower in the proposed technique than in breath-hold images but good agreement was found in clinically relevant ventricular measurements. In addition, the proposed method was fast to acquire, required minimal planning and provided full anatomical coverage with isotropic resolution.
Collapse
Affiliation(s)
| | | | - Alexander Gotschy
- Great Ormond Street Hospital, London, UK; Institute for Biomedical Engineering, University and ETH Zurich, Zurich, Switzerland.
| | | | | |
Collapse
|
25
|
Küstner T, Bustin A, Jaubert O, Hajhosseiny R, Masci PG, Neji R, Botnar R, Prieto C. Isotropic 3D Cartesian single breath-hold CINE MRI with multi-bin patch-based low-rank reconstruction. Magn Reson Med 2020; 84:2018-2033. [PMID: 32250492 DOI: 10.1002/mrm.28267] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/07/2019] [Revised: 03/08/2020] [Accepted: 03/09/2020] [Indexed: 12/16/2022]
Abstract
PURPOSE To develop a novel acquisition and reconstruction framework for isotropic 3D Cartesian cardiac CINE within a single breath-hold for left ventricle (LV) and whole-heart coverage. METHODS A variable-density Cartesian acquisition with spiral profile ordering, out-inward sampling, and acquisition-adaptive alternating tiny golden/golden angle increment between spiral arms is proposed to provide incoherent and nonredundant sampling within and among cardiac phases. A novel multi-bin patch-based low-rank reconstruction, named MB-PROST, is proposed to exploit redundant information on a local (within a patch), nonlocal (similar patches within a spatial neighborhood), and temporal (among all cardiac phases) scale with an implicit motion alignment among patches. The proposed multi-bin patch-based low-rank reconstruction reconstruction is compared against compressed sensing reconstruction, whereas LV function parameters derived from the proposed 3D CINE framework are compared against those estimated from conventional multislice 2D CINE imaging in 10 healthy subjects and 15 patients. RESULTS The proposed framework provides 3D cardiac CINE images with high spatial (1.9 mm3 ) and temporal resolution (˜50 ms) in a single breath-hold of ˜20 s for LV and ˜26 s for whole-heart coverage in healthy subjects. Shorter breath-hold durations of ˜13 to 15 s are feasible for LV coverage with slightly anisotropic resolution (1.9 × 1.9 × 2.5 mm) in patients. LV function parameters derived from 3D CINE were in good agreement with 2D CINE, with a bias of -0.1 mL/0.1 mL, -0.9 mL/-1.0 mL, -0.1%/-0.8%; and confidence intervals of ±1.7 mL/±3.7 mL, ±1.2 mL/±2.6 mL, and ±1.2%/±3.6% (10 healthy subjects/15 patients) for end-systolic volume, end-diastolic volume, and ejection fraction, respectively. CONCLUSION The proposed framework enables 3D isotropic cardiac CINE in a single breath-hold scan of ˜20 s/˜26 s for LV/whole-heart coverage, showing good agreement with clinical 2D CINE scans in terms of LV functional assessment.
Collapse
Affiliation(s)
- Thomas Küstner
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
| | - Aurelien Bustin
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
| | - Olivier Jaubert
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
| | - Reza Hajhosseiny
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
| | - Pier Giorgio Masci
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK
| | - Radhouene Neji
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK.,MR Research Collaborations, Siemens Healthcare Limited, Frimley, UK
| | - René Botnar
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK.,Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Claudia Prieto
- School of Biomedical Engineering and Imaging Sciences, King's College London, St. Thomas' Hospital, London, UK.,Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
26
|
Gottwald LM, Peper ES, Zhang Q, Coolen BF, Strijkers GJ, Nederveen AJ, van Ooij P. Pseudo-spiral sampling and compressed sensing reconstruction provides flexibility of temporal resolution in accelerated aortic 4D flow MRI: A comparison with k-t principal component analysis. NMR IN BIOMEDICINE 2020; 33:e4255. [PMID: 31957927 PMCID: PMC7079056 DOI: 10.1002/nbm.4255] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/27/2019] [Revised: 12/16/2019] [Accepted: 12/17/2019] [Indexed: 06/10/2023]
Abstract
INTRODUCTION Time-resolved three-dimensional phase contrast MRI (4D flow) of aortic blood flow requires acceleration to reduce scan time. Two established techniques for highly accelerated 4D flow MRI are k-t principal component analysis (k-t PCA) and compressed sensing (CS), which employ either regular or random k-space undersampling. The goal of this study was to gain insights into the quantitative differences between k-t PCA- and CS-derived aortic blood flow, especially for high temporal resolution CS 4D flow MRI. METHODS The scan protocol consisted of both k-t PCA and CS accelerated 4D flow MRI, as well as a 2D flow reference scan through the ascending aorta acquired in 15 subjects. 4D flow scans were accelerated with factor R = 8. For CS accelerated scans, we used a pseudo-spiral Cartesian sampling scheme, which could additionally be reconstructed at higher temporal resolution, resulting in R = 13. 4D flow data were compared with the 2D flow scan in terms of flow, peak flow and stroke volume. A 3D peak systolic voxel-wise velocity and wall shear stress (WSS) comparison between k-t PCA and CS 4D flow was also performed. RESULTS The mean difference in flow/peak flow/stroke volume between the 2D flow scan and the 4D flow CS with R = 8 and R = 13 was 4.2%/9.1%/3.0% and 5.3%/7.1%/1.9%, respectively, whereas for k-t PCA with R = 8 the difference was 9.7%/25.8%/10.4%. In the voxel-by-voxel 4D flow comparison we found 13.6% and 3.5% lower velocity and WSS values of k-t PCA compared with CS with R = 8, and 15.9% and 5.5% lower velocity and WSS values of k-t PCA compared with CS with R = 13. CONCLUSION Pseudo-spiral accelerated 4D flow acquisitions in combination with CS reconstruction provides a flexible choice of temporal resolution. We showed that our proposed strategy achieves better agreement in flow values with 2D reference scans compared with using k-t PCA accelerated acquisitions.
Collapse
Affiliation(s)
- Lukas M. Gottwald
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Eva S. Peper
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Qinwei Zhang
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Bram F. Coolen
- Department of Biomedical Engineering and Physics, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Gustav J. Strijkers
- Department of Biomedical Engineering and Physics, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Aart J. Nederveen
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| | - Pim van Ooij
- Department of Radiology and Nuclear Medicine, Amsterdam University Medical CentersUniversity of Amsterdamthe Netherlands
| |
Collapse
|
27
|
Bustin A, Fuin N, Botnar RM, Prieto C. From Compressed-Sensing to Artificial Intelligence-Based Cardiac MRI Reconstruction. Front Cardiovasc Med 2020; 7:17. [PMID: 32158767 PMCID: PMC7051921 DOI: 10.3389/fcvm.2020.00017] [Citation(s) in RCA: 59] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/30/2019] [Accepted: 01/31/2020] [Indexed: 12/28/2022] Open
Abstract
Cardiac magnetic resonance (CMR) imaging is an important tool for the non-invasive assessment of cardiovascular disease. However, CMR suffers from long acquisition times due to the need of obtaining images with high temporal and spatial resolution, different contrasts, and/or whole-heart coverage. In addition, both cardiac and respiratory-induced motion of the heart during the acquisition need to be accounted for, further increasing the scan time. Several undersampling reconstruction techniques have been proposed during the last decades to speed up CMR acquisition. These techniques rely on acquiring less data than needed and estimating the non-acquired data exploiting some sort of prior information. Parallel imaging and compressed sensing undersampling reconstruction techniques have revolutionized the field, enabling 2- to 3-fold scan time accelerations to become standard in clinical practice. Recent scientific advances in CMR reconstruction hinge on the thriving field of artificial intelligence. Machine learning reconstruction approaches have been recently proposed to learn the non-linear optimization process employed in CMR reconstruction. Unlike analytical methods for which the reconstruction problem is explicitly defined into the optimization process, machine learning techniques make use of large data sets to learn the key reconstruction parameters and priors. In particular, deep learning techniques promise to use deep neural networks (DNN) to learn the reconstruction process from existing datasets in advance, providing a fast and efficient reconstruction that can be applied to all newly acquired data. However, before machine learning and DNN can realize their full potentials and enter widespread clinical routine for CMR image reconstruction, there are several technical hurdles that need to be addressed. In this article, we provide an overview of the recent developments in the area of artificial intelligence for CMR image reconstruction. The underlying assumptions of established techniques such as compressed sensing and low-rank reconstruction are briefly summarized, while a greater focus is given to recent advances in dictionary learning and deep learning based CMR reconstruction. In particular, approaches that exploit neural networks as implicit or explicit priors are discussed for 2D dynamic cardiac imaging and 3D whole-heart CMR imaging. Current limitations, challenges, and potential future directions of these techniques are also discussed.
Collapse
Affiliation(s)
- Aurélien Bustin
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - Niccolo Fuin
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
| | - René M. Botnar
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| | - Claudia Prieto
- Department of Biomedical Engineering, School of Biomedical Engineering and Imaging Sciences, King's College London, London, United Kingdom
- Escuela de Ingeniería, Pontificia Universidad Católica de Chile, Santiago, Chile
| |
Collapse
|
28
|
Bruijnen T, Stemkens B, van den Berg CAT, Tijssen RHN. Prospective GIRF-based RF phase cycling to reduce eddy current-induced steady-state disruption in bSSFP imaging. Magn Reson Med 2019; 84:115-127. [PMID: 31755580 PMCID: PMC7154723 DOI: 10.1002/mrm.28097] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2019] [Revised: 11/04/2019] [Accepted: 11/04/2019] [Indexed: 11/07/2022]
Abstract
Purpose To propose an explicit Balanced steady‐state free precession (bSSFP) signal model that predicts eddy current‐induced steady‐state disruptions and to provide a prospective, practical, and general eddy current compensation method. Theory and Methods Gradient impulse response functions (GIRF) were used to simulate trajectory‐specific eddy current‐induced phase errors at the end of a repetition block. These phase errors were included in bloch simulations to establish a bSSFP signal model to predict steady‐state disruptions and their corresponding image artifacts. The signal model was embedded in the MR system and used to compensate the phase errors by prospectively modifying the phase cycling scheme of the RF pulse. The signal model and eddy current compensation method were validated in phantom and in vivo experiments. In addition, the signal model was used to analyze pre‐existing eddy current mitigation methods, such as 2D tiny golden angle radial and 3D paired phase encoded Cartesian acquisitions. Results The signal model predicted eddy current‐induced image artifacts, with the zeroth‐order GIRF being the primary factor to predict the steady‐state disruption. Prospective RF phase cycling schemes were automatically computed online and considerably reduced eddy current‐induced image artifacts. The signal model provides a direct relationship for the smoothness of k‐space trajectories, which explains the effectiveness of phase encode pairing and tiny golden angle trajectory. Conclusions The proposed signal model can accurately predict eddy current‐induced steady‐state disruptions for bSSFP imaging. The signal model can be used to derive the eddy current‐induced phase errors required for trajectory‐specific RF phase cycling schemes, which considerably reduce eddy current‐induced image artifacts.
Collapse
Affiliation(s)
- Tom Bruijnen
- Department of RadiotherapyUniversity Medical Center UtrechtUtrechtThe Netherlands
- Computational Imaging Group for MRI diagnostics and therapy, Centre for Image SciencesUniversity Medical Center UtrechtUtrechtThe Netherlands
| | - Bjorn Stemkens
- Department of RadiotherapyUniversity Medical Center UtrechtUtrechtThe Netherlands
- Computational Imaging Group for MRI diagnostics and therapy, Centre for Image SciencesUniversity Medical Center UtrechtUtrechtThe Netherlands
| | - Cornelis Antonius Theodorus van den Berg
- Department of RadiotherapyUniversity Medical Center UtrechtUtrechtThe Netherlands
- Computational Imaging Group for MRI diagnostics and therapy, Centre for Image SciencesUniversity Medical Center UtrechtUtrechtThe Netherlands
| | | |
Collapse
|
29
|
Greer JS, Wang X, Wang Y, Pinho MC, Maldjian JA, Pedrosa I, Madhuranthakam AJ. Robust pCASL perfusion imaging using a 3D Cartesian acquisition with spiral profile reordering (CASPR). Magn Reson Med 2019; 82:1713-1724. [PMID: 31231894 PMCID: PMC6743738 DOI: 10.1002/mrm.27862] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2018] [Revised: 05/22/2019] [Accepted: 05/23/2019] [Indexed: 12/15/2022]
Abstract
PURPOSE To improve the robustness of arterial spin-labeled measured perfusion using a novel Cartesian acquisition with spiral profile reordering (CASPR) 3D turbo spin echo (TSE) in the brain and kidneys. METHODS The CASPR view ordering followed a pseudo-spiral trajectory on a Cartesian grid, by sampling the center of k-space at the beginning of each echo train of a segmented 3D TSE acquisition. With institutional review board approval and written informed consent, 14 normal subjects (9 brain and 5 kidneys) were scanned with pCASL perfusion imaging using 3D CASPR and compared against 3D linear TSE (brain and kidneys), the established 2D EPI and 3D gradient and spin echo perfusion (brain), and 2D single-shot turbo spin-echo perfusion (kidneys). The SNR and the quantitative perfusion values were compared among different acquisitions. RESULTS 3D CASPR TSE achieved robust perfusion across all slices compared to 3D linear TSE in the brain and kidneys. Compared to 2D EPI, 3D CASPR TSE showed higher SNR across the brain (P < 0.01), and exhibited good agreement (36.4 ± 4.7 and 36.9 ± 5.3 mL/100 g/min with 2D EPI and 3D CASPR, respectively), and with 3D gradient and spin echo (27.9 ± 7.2 mL/100 g/min). Compared to a single slice 2D single-shot turbo spin-echo acquisition, 3D CASPR TSE achieved robust perfusion across the entire kidneys in similar scan time with comparable quantified perfusion values (154.1 ± 74.6 and 151.7 ± 70.6 mL/100 g/min with 2D single-shot turbo spin-echo and 3D CASPR, respectively). CONCLUSION The CASPR view ordering with 3D TSE achieves robust arterial spin-labeled perfusion in the brain and kidneys because of the sampling of the center of k-space at the beginning of each echo train.
Collapse
Affiliation(s)
- Joshua S. Greer
- Department of Bioengineering, University of Texas at Dallas, Richardson, TX
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX
| | - Xinzeng Wang
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX
| | - Yiming Wang
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX
| | - Marco C. Pinho
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX
- Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX
| | - Joseph A. Maldjian
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX
- Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX
| | - Ivan Pedrosa
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX
- Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX
| | - Ananth J. Madhuranthakam
- Department of Radiology, UT Southwestern Medical Center, Dallas, TX
- Advanced Imaging Research Center, UT Southwestern Medical Center, Dallas, TX
| |
Collapse
|
30
|
Menchón-Lara RM, Simmross-Wattenberg F, Casaseca-de-la-Higuera P, Martín-Fernández M, Alberola-López C. Reconstruction techniques for cardiac cine MRI. Insights Imaging 2019; 10:100. [PMID: 31549235 PMCID: PMC6757088 DOI: 10.1186/s13244-019-0754-2] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/09/2019] [Accepted: 05/17/2019] [Indexed: 12/17/2022] Open
Abstract
The present survey describes the state-of-the-art techniques for dynamic cardiac magnetic resonance image reconstruction. Additionally, clinical relevance, main challenges, and future trends of this image modality are outlined. Thus, this paper aims to provide a general vision about cine MRI as the standard procedure in functional evaluation of the heart, focusing on technical methodologies.
Collapse
Affiliation(s)
- Rosa-María Menchón-Lara
- Laboratorio de Procesado de Imagen. Escuela Técnica Superior de Ingenieros de Telecomunicación, Universidad de Valladolid, Campus Miguel Delibes, Valladolid, 47011, Spain.
| | - Federico Simmross-Wattenberg
- Laboratorio de Procesado de Imagen. Escuela Técnica Superior de Ingenieros de Telecomunicación, Universidad de Valladolid, Campus Miguel Delibes, Valladolid, 47011, Spain
| | - Pablo Casaseca-de-la-Higuera
- Laboratorio de Procesado de Imagen. Escuela Técnica Superior de Ingenieros de Telecomunicación, Universidad de Valladolid, Campus Miguel Delibes, Valladolid, 47011, Spain
| | - Marcos Martín-Fernández
- Laboratorio de Procesado de Imagen. Escuela Técnica Superior de Ingenieros de Telecomunicación, Universidad de Valladolid, Campus Miguel Delibes, Valladolid, 47011, Spain
| | - Carlos Alberola-López
- Laboratorio de Procesado de Imagen. Escuela Técnica Superior de Ingenieros de Telecomunicación, Universidad de Valladolid, Campus Miguel Delibes, Valladolid, 47011, Spain
| |
Collapse
|
31
|
Yang F, Zhang Y, Lei P, Wang L, Miao Y, Xie H, Zeng Z. A Deep Learning Segmentation Approach in Free-Breathing Real-Time Cardiac Magnetic Resonance Imaging. BIOMED RESEARCH INTERNATIONAL 2019; 2019:5636423. [PMID: 31467898 PMCID: PMC6699314 DOI: 10.1155/2019/5636423] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 04/20/2019] [Accepted: 07/17/2019] [Indexed: 12/04/2022]
Abstract
OBJECTIVES The purpose of this study was to segment the left ventricle (LV) blood pool, LV myocardium, and right ventricle (RV) blood pool of end-diastole and end-systole frames in free-breathing cardiac magnetic resonance (CMR) imaging. Automatic and accurate segmentation of cardiac structures could reduce the postprocessing time of cardiac function analysis. METHOD We proposed a novel deep learning network using a residual block for the segmentation of the heart and a random data augmentation strategy to reduce the training time and the problem of overfitting. Automated cardiac diagnosis challenge (ACDC) data were used for training, and the free-breathing CMR data were used for validation and testing. RESULTS The average Dice was 0.919 (LV), 0.806 (myocardium), and 0.818 (RV). The average IoU was 0.860 (LV), 0.699 (myocardium), and 0.761 (RV). CONCLUSIONS The proposed method may aid in the segmentation of cardiac images and improves the postprocessing efficiency of cardiac function analysis.
Collapse
Affiliation(s)
- Fan Yang
- Key Laboratory of Biology and Medical Engineering, Guizhou Medical University, Guiyang 550025, China
- School of Biology & Engineering, Guizhou Medical University, Guiyang 550025, China
| | - Yan Zhang
- Department of Radiology, The Affiliated Hospital of Guizhou Medical University, Guiyang 550004, China
| | - Pinggui Lei
- Department of Radiology, The Affiliated Hospital of Guizhou Medical University, Guiyang 550004, China
| | - Lihui Wang
- Key Laboratory of Intelligent Medical Image Analysis and Precise Diagnosis of Guizhou Province, School of Computer Science and Technology, Guizhou University, Guiyang 550025, China
| | - Yuehong Miao
- Key Laboratory of Biology and Medical Engineering, Guizhou Medical University, Guiyang 550025, China
- School of Biology & Engineering, Guizhou Medical University, Guiyang 550025, China
| | - Hong Xie
- Department of Radiology, The Affiliated Hospital of Guizhou Medical University, Guiyang 550004, China
| | - Zhu Zeng
- Key Laboratory of Biology and Medical Engineering, Guizhou Medical University, Guiyang 550025, China
| |
Collapse
|
32
|
Jaeschke SHF, Robson MD, Hess AT. Scattering matrix imaging pulse design for real-time respiration and cardiac motion monitoring. Magn Reson Med 2019; 82:2169-2177. [PMID: 31317579 PMCID: PMC6771869 DOI: 10.1002/mrm.27884] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/18/2019] [Revised: 05/01/2019] [Accepted: 06/07/2019] [Indexed: 12/26/2022]
Abstract
Purpose The scattering matrix (S‐matrix) of a parallel transmit (pTx) coil is sensitive to physiological motion but requires additional monitoring RF pulses to be measured. In this work, we present and evaluate pTx RF pulse designs that simultaneously excite for imaging and measure the S‐matrix to generate real‐time motion signals without prolonging the image sequence. Theory and Methods Three pTx waveforms for measuring the S‐matrix were identified and superimposed onto the imaging excitation RF pulses: (1) time division multiplexing, (2) frequency division multiplexing, and (3) code division multiplexing. These 3 methods were evaluated in healthy volunteers for scattering sensitivity and image artefacts. The S‐matrix and real‐time motion signals were calculated on the image calculation environment of the MR scanner. Prospective cardiac triggers were identified in early systole as a high rate of change of the cardiac motion signal. Monitoring accuracy was compared against electrocardiogram or the imaged diaphragm position. Results All 3 monitoring approaches measure the S‐matrix during image excitation with quality correlated to input power. No image artefacts were observed for frequency multiplexing, and low energy artefacts were observed in the other methods. The accuracy of the achieved prospective cardiac gating was 15 ± 16 ms for breath hold and 24 ± 17 ms during free breathing. The diaphragm position prediction accuracy was 1.3 ± 0.9 mm. In all volunteers, good quality cine images were acquired for breath hold scans and dual gated CINEs were demonstrated. Conclusion The S‐matrix can be measured during image excitation to generate real‐time cardiac and respiratory motion signals for prospective gating. No artefacts are introduced when frequency division multiplexing is used.
Collapse
Affiliation(s)
- Sven H F Jaeschke
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom
| | - Matthew D Robson
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom.,Perspectum Diagnostics, Oxford, United Kingdom
| | - Aaron T Hess
- Oxford Centre for Clinical Magnetic Resonance Research, Division of Cardiovascular Medicine, Radcliffe Department of Medicine, University of Oxford, Oxford, United Kingdom.,BHF Centre of Research Excellence, University of Oxford, Oxford, United Kingdom
| |
Collapse
|
33
|
Pednekar AS, Jadhav S, Noel C, Masand P. Free-breathing Cardiorespiratory Synchronized Cine MRI for Assessment of Left and Right Ventricular Volume and Function in Sedated Children and Adolescents with Impaired Breath-holding Capacity. Radiol Cardiothorac Imaging 2019; 1:e180027. [PMID: 33778501 PMCID: PMC7970102 DOI: 10.1148/ryct.2019180027] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/18/2018] [Revised: 03/28/2019] [Accepted: 04/10/2019] [Indexed: 11/11/2022]
Abstract
PURPOSE To prospectively compare left ventricular and right ventricular volume, function, and image quality of a free-breathing (FB) cardiorespiratory synchronized balanced steady-state free precession cine MRI sequence with that of a standard of reference breath-hold (BH) technique in sedated children and adolescents who are unable to perform BHs. MATERIALS AND METHODS Cohort 1 included 30 patients able to perform BHs (mean age, 19 years; age range, 9-69 years). Cohort 1 underwent both BH and FB cine short-axis imaging with identical acquisition parameters. Cohort 2 included 63 patients unable to perform BHs (50 sedated patients [mean age, 9 years; age range, 4 months to 28 years], 13 unsedated patients [mean age, 21 years; age range, 8-58 years]). Cohort 2 underwent FB cine imaging in multiple views with spatiotemporal resolution equivalent to BH imaging. Comparative quantitative analysis was performed for left ventricular and right ventricular volumes in cohort 1 and for qualitative image quality scores in all patients. RESULTS Global left ventricular and right ventricular volumetric indexes and image quality scores were comparable between BH and FB sequences in cohort 1. FB image quality was graded as excellent (37 sequences), good (197 sequences), adequate (26 sequences), and suboptimal (three sequences) for 263 cine sequences in cohort 2. In cohort 1, de facto image acquisition time for FB (6.1 minutes ± 1.9 [standard deviation]) was comparable to the equivalent for BH (6.1 minutes ± 2.6) for a stack of 14 sections. CONCLUSION In cohorts of sedated children, adolescents, and young adults unable to perform BHs consistently, left ventricular and right ventricular volumes and function were comparable and image quality was noninferior between FB and standard of reference BH techniques.© RSNA, 2019.
Collapse
Affiliation(s)
- Amol S. Pednekar
- From the Edward B. Singleton Department of Pediatric Radiology (A.S.P., S.J., P.M.) and Department of Pediatric Cardiology (C.N.), Texas Children’s Hospital, Mark A. Wallace Tower, 6701 Fannin St, Suite 470, Houston, TX 77030-2399
| | - Siddharth Jadhav
- From the Edward B. Singleton Department of Pediatric Radiology (A.S.P., S.J., P.M.) and Department of Pediatric Cardiology (C.N.), Texas Children’s Hospital, Mark A. Wallace Tower, 6701 Fannin St, Suite 470, Houston, TX 77030-2399
| | - Cory Noel
- From the Edward B. Singleton Department of Pediatric Radiology (A.S.P., S.J., P.M.) and Department of Pediatric Cardiology (C.N.), Texas Children’s Hospital, Mark A. Wallace Tower, 6701 Fannin St, Suite 470, Houston, TX 77030-2399
| | - Prakash Masand
- From the Edward B. Singleton Department of Pediatric Radiology (A.S.P., S.J., P.M.) and Department of Pediatric Cardiology (C.N.), Texas Children’s Hospital, Mark A. Wallace Tower, 6701 Fannin St, Suite 470, Houston, TX 77030-2399
| |
Collapse
|
34
|
Ahmad I, Hussain F, Khan SA, Akram U, Jeon G. CPS-based fully automatic cardiac left ventricle and left atrium segmentation in 3D MRI. JOURNAL OF INTELLIGENT & FUZZY SYSTEMS 2019. [DOI: 10.3233/jifs-169974] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Affiliation(s)
- Ibtihaj Ahmad
- Department of Computer and Software Engineering, College of EME, National University of Sciences and Technology, Pakistan
| | - Farhan Hussain
- Department of Computer and Software Engineering, College of EME, National University of Sciences and Technology, Pakistan
| | - Shoab Ahmad Khan
- Department of Computer and Software Engineering, College of EME, National University of Sciences and Technology, Pakistan
| | - Usman Akram
- Department of Computer and Software Engineering, College of EME, National University of Sciences and Technology, Pakistan
| | - Gwanggil Jeon
- Department of Embedded Systems Engineering, College of Information Technology, Incheon National University, Korea
| |
Collapse
|
35
|
Zhou R, Yang Y, Mathew RC, Mugler JP, Weller DS, Kramer CM, Ahmed AH, Jacob M, Salerno M. Free-breathing cine imaging with motion-corrected reconstruction at 3T using SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS). Magn Reson Med 2019; 82:706-720. [PMID: 31006916 DOI: 10.1002/mrm.27763] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2018] [Revised: 03/12/2019] [Accepted: 03/15/2019] [Indexed: 12/28/2022]
Abstract
PURPOSE To develop a continuous-acquisition cardiac self-gated spiral pulse sequence and a respiratory motion-compensated reconstruction strategy for free-breathing cine imaging. METHODS Cine data were acquired continuously on a 3T scanner for 8 seconds per slice without ECG gating or breath-holding, using a golden-angle gradient echo spiral pulse sequence. Cardiac motion information was extracted by applying principal component analysis on the gridded 8 × 8 k-space center data. Respiratory motion was corrected by rigid registration on each heartbeat. Images were reconstructed using a low-rank and sparse (L+S) technique. This strategy was evaluated in 37 healthy subjects and 8 subjects undergoing clinical cardiac MR studies. Image quality was scored (1-5 scale) in a blinded fashion by 2 experienced cardiologists. In 13 subjects with whole-heart coverage, left ventricular ejection fraction (LVEF) from SPiral Acquisition with Respiratory correction and Cardiac Self-gating (SPARCS) was compared to that from a standard ECG-gated breath-hold balanced steady-state free precession (bSSFP) cine sequence. RESULTS The self-gated signal was successfully extracted in all cases and demonstrated close agreement with the acquired ECG signal (mean bias, -0.22 ms). The mean image score across all subjects was 4.0 for reconstruction using the L+S model. There was good agreement between the LVEF derived from SPARCS and the gold-standard bSSFP technique. CONCLUSION SPARCS successfully images cardiac function without the need for ECG gating or breath-holding. With an 8-second data acquisition per slice, whole-heart cine images with clinically acceptable spatial and temporal resolution and image quality can be acquired in <90 seconds of free-breathing acquisition.
Collapse
Affiliation(s)
- Ruixi Zhou
- Department of Biomedical Engineering, University of Virginia Health System, Charlottesville, Virginia
| | - Yang Yang
- Department of Medicine, Cardiovascular Division, University of Virginia Health System, Charlottesville, Virginia.,Translational and Molecular Imaging Institute and Department of Radiology, Icahn School of Medicine at Mount Sinai, New York, New York
| | - Roshin C Mathew
- Department of Medicine, Cardiovascular Division, University of Virginia Health System, Charlottesville, Virginia.,Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, Virginia
| | - John P Mugler
- Department of Biomedical Engineering, University of Virginia Health System, Charlottesville, Virginia.,Department of Medicine, Cardiovascular Division, University of Virginia Health System, Charlottesville, Virginia.,Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, Virginia
| | - Daniel S Weller
- Department of Electrical and Computer Engineering, University of Virginia, Charlottesville, Virginia
| | - Christopher M Kramer
- Department of Medicine, Cardiovascular Division, University of Virginia Health System, Charlottesville, Virginia.,Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, Virginia
| | - Abdul Haseeb Ahmed
- Department of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa
| | - Mathews Jacob
- Department of Electrical and Computer Engineering, University of Iowa, Iowa City, Iowa
| | - Michael Salerno
- Department of Biomedical Engineering, University of Virginia Health System, Charlottesville, Virginia.,Department of Medicine, Cardiovascular Division, University of Virginia Health System, Charlottesville, Virginia.,Radiology and Medical Imaging, University of Virginia Health System, Charlottesville, Virginia
| |
Collapse
|
36
|
Velasco Forte MN, Valverde I, Prabhu N, Correia T, Narayan SA, Bell A, Mathur S, Razavi R, Hussain T, Pushparajah K, Henningsson M. Visualization of coronary arteries in paediatric patients using whole-heart coronary magnetic resonance angiography: comparison of image-navigation and the standard approach for respiratory motion compensation. J Cardiovasc Magn Reson 2019; 21:13. [PMID: 30798789 PMCID: PMC6388473 DOI: 10.1186/s12968-019-0525-8] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/09/2018] [Accepted: 02/05/2019] [Indexed: 11/10/2022] Open
Abstract
AIMS To investigate the use of respiratory motion compensation using image-based navigation (iNAV) with constant respiratory efficiency using single end-expiratory thresholding (CRUISE) for coronary magnetic resonance angiography (CMRA), and compare it to the conventional diaphragmatic navigator (dNAV) in paediatric patients with congenital or suspected heart disease. METHODS iNAV allowed direct tracking of the respiratory heart motion and was generated using balanced steady state free precession startup echoes. Respiratory gating was achieved using CRUISE with a fixed 50% efficiency. Whole-heart CMRA was acquired with 1.3 mm isotropic resolution. For comparison, CMRA with identical imaging parameters were acquired using dNAV. Scan time, visualization of coronary artery origins and mid-course, imaging quality and sharpness was compared between the two sequences. RESULTS Forty patients (13 females; median weight: 44 kg; median age: 12.6, range: 3 months-17 years) were enrolled. 25 scans were performed in awake patients. A contrast agent was used in 22 patients. The scan time was significantly reduced using iNAV for awake patients (iNAV 7:48 ± 1:26 vs dNAV 9:48 ± 3:11, P = 0.01) but not for patients under general anaesthesia (iNAV = 6:55 ± 1:50 versus dNAV = 6:32 ± 2:16; P = 0.32). In 98% of the cases, iNAV image quality had an equal or higher score than dNAV. The visual score analysis showed a clear difference, favouring iNAV (P = 0.002). The right coronary artery and the left anterior descending vessel sharpness was significantly improved (iNAV: 56.8% ± 10.1% vs dNAV: 53.7% ± 9.9%, P < 0.002 and iNAV: 55.8% ± 8.6% vs dNAV: 53% ± 9.2%, P = 0.001, respectively). CONCLUSION iNAV allows for a higher success-rate and clearer depiction of the mid-course of coronary arteries in paediatric patients. Its acquisition time is shorter in awake patients and image quality score is equal or superior to the conventional method in most cases.
Collapse
Affiliation(s)
- Mari Nieves Velasco Forte
- Division of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London, UK
- Cardiovascular Pathology Unit, Institute of Biomedicine of Seville, IBIS, Virgen del Rocio University Hospital/CSIC/University of Seville, Seville, Spain
| | - Israel Valverde
- Division of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London, UK
- Cardiovascular Pathology Unit, Institute of Biomedicine of Seville, IBIS, Virgen del Rocio University Hospital/CSIC/University of Seville, Seville, Spain
| | - Nanda Prabhu
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London, UK
| | - Teresa Correia
- Division of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
| | - Srinivas Ananth Narayan
- Division of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London, UK
| | - Aaron Bell
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London, UK
| | - Sujeev Mathur
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London, UK
| | - Reza Razavi
- Division of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London, UK
| | - Tarique Hussain
- Division of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
- Department of Pediatrics, University of Texas Southwestern Medical Center, 1935 Medical District Drive, Dallas, USA
| | - Kuberan Pushparajah
- Division of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
- Department of Congenital Heart Disease, Evelina London Children’s Hospital, Guy’s and St Thomas NHS Foundation Trust, London, UK
| | - Markus Henningsson
- Division of Biomedical Engineering and Imaging Sciences, King’s College London, London, UK
- Division of Cardiovascular Medicine, Department of Medical and Health Sciences, Linköping University, Linköping, Sweden
| |
Collapse
|
37
|
Godino-Moya A, Royuela-Del-Val J, Usman M, Menchón-Lara RM, Martín-Fernández M, Prieto C, Alberola-López C. Space-time variant weighted regularization in compressed sensing cardiac cine MRI. Magn Reson Imaging 2019; 58:44-55. [PMID: 30654163 DOI: 10.1016/j.mri.2019.01.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/05/2018] [Revised: 12/02/2018] [Accepted: 01/05/2019] [Indexed: 11/16/2022]
Abstract
PURPOSE To analyze the impact on image quality and motion fidelity of a motion-weighted space-time variant regularization term in compressed sensing cardiac cine MRI. METHODS k-t SPARSE-SENSE with temporal total variation (tTV) is used as the base reconstruction algorithm. Motion in the dynamic image is estimated by means of a robust registration technique for non-rigid motion. The resulting deformation fields are used to leverage the regularization term. The results are compared with standard k-t SPARSE-SENSE with tTV regularization as well as with an improved version of this algorithm that makes use of tTV and temporal Fast Fourier Transform regularization in x-f domain. RESULTS The proposed method with space-time variant regularization provides higher motion fidelity and image quality than the two previously reported methods. Difference images between undersampled reconstruction and fully sampled reference images show less systematic errors with the proposed approach. CONCLUSIONS Usage of a space-time variant regularization offers reconstructions with better image quality than the state of the art approaches used for comparison.
Collapse
Affiliation(s)
- Alejandro Godino-Moya
- Laboratorio de Procesado de Imagen, Department of Teoría de la Señal y Comunicaciones e Ingeniería Telemática, ETSIT, Universidad de Valladolid, Campus Miguel Delibes s.n., Valladolid 47011, Spain.
| | - Javier Royuela-Del-Val
- Laboratorio de Procesado de Imagen, Department of Teoría de la Señal y Comunicaciones e Ingeniería Telemática, ETSIT, Universidad de Valladolid, Campus Miguel Delibes s.n., Valladolid 47011, Spain
| | - Muhammad Usman
- Department of Computer Science, University College London, London, United Kingdom
| | - Rosa-María Menchón-Lara
- Laboratorio de Procesado de Imagen, Department of Teoría de la Señal y Comunicaciones e Ingeniería Telemática, ETSIT, Universidad de Valladolid, Campus Miguel Delibes s.n., Valladolid 47011, Spain
| | - Marcos Martín-Fernández
- Laboratorio de Procesado de Imagen, Department of Teoría de la Señal y Comunicaciones e Ingeniería Telemática, ETSIT, Universidad de Valladolid, Campus Miguel Delibes s.n., Valladolid 47011, Spain
| | - Claudia Prieto
- King's College London, School of Biomedical Engineering and Imaging Sciences, London, United Kingdom
| | - Carlos Alberola-López
- Laboratorio de Procesado de Imagen, Department of Teoría de la Señal y Comunicaciones e Ingeniería Telemática, ETSIT, Universidad de Valladolid, Campus Miguel Delibes s.n., Valladolid 47011, Spain
| |
Collapse
|
38
|
Kamesh Iyer S, Moon B, Hwuang E, Han Y, Solomon M, Litt H, Witschey WR. Accelerated free-breathing 3D T1ρ cardiovascular magnetic resonance using multicoil compressed sensing. J Cardiovasc Magn Reson 2019; 21:5. [PMID: 30626437 PMCID: PMC6327532 DOI: 10.1186/s12968-018-0507-2] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/04/2018] [Accepted: 11/13/2018] [Indexed: 12/26/2022] Open
Abstract
BACKGROUND Endogenous contrast T1ρ cardiovascular magnetic resonance (CMR) can detect scar or infiltrative fibrosis in patients with ischemic or non-ischemic cardiomyopathy. Existing 2D T1ρ techniques have limited spatial coverage or require multiple breath-holds. The purpose of this project was to develop an accelerated, free-breathing 3D T1ρ mapping sequence with whole left ventricle coverage using a multicoil, compressed sensing (CS) reconstruction technique for rapid reconstruction of undersampled k-space data. METHODS We developed a cardiac- and respiratory-gated, free-breathing 3D T1ρ sequence and acquired data using a variable-density k-space sampling pattern (A = 3). The effect of the transient magnetization trajectory, incomplete recovery of magnetization between T1ρ-preparations (heart rate dependence), and k-space sampling pattern on T1ρ relaxation time error and edge blurring was analyzed using Bloch simulations for normal and chronically infarcted myocardium. Sequence accuracy and repeatability was evaluated using MnCl2 phantoms with different T1ρ relaxation times and compared to 2D measurements. We further assessed accuracy and repeatability in healthy subjects and compared these results to 2D breath-held measurements. RESULTS The error in T1ρ due to incomplete recovery of magnetization between T1ρ-preparations was T1ρhealthy = 6.1% and T1ρinfarct = 10.8% at 60 bpm and T1ρhealthy = 13.2% and T1ρinfarct = 19.6% at 90 bpm. At a heart rate of 60 bpm, error from the combined effects of readout-dependent magnetization transients, k-space undersampling and reordering was T1ρhealthy = 12.6% and T1ρinfarct = 5.8%. CS reconstructions had improved edge sharpness (blur metric = 0.15) compared to inverse Fourier transform reconstructions (blur metric = 0.48). There was strong agreement between the mean T1ρ estimated from the 2D and accelerated 3D data (R2 = 0.99; P < 0.05) acquired on the MnCl2 phantoms. The mean R1ρ estimated from the accelerated 3D sequence was highly correlated with MnCl2 concentration (R2 = 0.99; P < 0.05). 3D T1ρ acquisitions were successful in all human subjects. There was no significant bias between undersampled 3D T1ρ and breath-held 2D T1ρ (mean bias = 0.87) and the measurements had good repeatability (COV2D = 6.4% and COV3D = 7.1%). CONCLUSIONS This is the first report of an accelerated, free-breathing 3D T1ρ mapping of the left ventricle. This technique may improve non-contrast myocardial tissue characterization in patients with heart disease in a scan time appropriate for patients.
Collapse
Affiliation(s)
- Srikant Kamesh Iyer
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104 USA
| | - Brianna Moon
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104 USA
| | - Eileen Hwuang
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104 USA
| | - Yuchi Han
- Department of Medicine, University of Pennsylvania, Philadelphia, PA 19104 USA
| | - Michael Solomon
- Department of Bioengineering, University of Pennsylvania, Philadelphia, PA 19104 USA
| | - Harold Litt
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104 USA
- Department of Medicine, University of Pennsylvania, Philadelphia, PA 19104 USA
| | - Walter R. Witschey
- Department of Radiology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104 USA
| |
Collapse
|
39
|
Hoad C, Clarke C, Marciani L, Graves MJ, Corsetti M. Will MRI of gastrointestinal function parallel the clinical success of cine cardiac MRI? Br J Radiol 2019; 92:20180433. [PMID: 30299989 PMCID: PMC6435057 DOI: 10.1259/bjr.20180433] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/14/2018] [Revised: 09/21/2018] [Accepted: 10/03/2018] [Indexed: 12/11/2022] Open
Abstract
Cine cardiac MRI is generally accepted as the "gold-standard" for functional myocardial assessment. It only took a few years after the development of commercial MRI systems for functional cardiac imaging to be developed, with electrocardiogram (ECG)-gated cine imaging first reported in 1988. The function of the gastrointestinal (GI) tract is more complex to study compared to the heart. However, the idea of having a non-invasive tool to study the GI function that also allows the concurrent assessment of different aspects of this function has become more and more attractive in the gastroenterological field. This review summarises key literature of the last 5 years to describe the current status of MRI in respect to the evaluation of GI function, highlighting the gaps and challenges and the future prospects. As the clinical application of a new technique requires that its clinical utility is confirmed by demonstration of its ability to enable clinicians to make a diagnosis and/or predict the treatment response, this review also considers whether or not this has been achieved, and how MRI has been validated against techniques currently recognised as the gold standard in clinical practice.
Collapse
Affiliation(s)
| | - Christopher Clarke
- Department of Radiology, Nottingham University Hospitals NHS Trust, Nottingham, UK
| | | | - Martin John Graves
- Department of Radiology, Cambridge University Hospitals NHS Trust, Cambridge, UK
| | | |
Collapse
|
40
|
Zhang X, Xie G, Lu N, Zhu Y, Wei Z, Su S, Shi C, Yan F, Liu X, Qiu B, Fan Z. 3D self-gated cardiac cine imaging at 3 Tesla using stack-of-stars bSSFP with tiny golden angles and compressed sensing. Magn Reson Med 2018; 81:3234-3244. [PMID: 30474151 DOI: 10.1002/mrm.27612] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/12/2018] [Revised: 10/25/2018] [Accepted: 10/29/2018] [Indexed: 12/25/2022]
Abstract
PURPOSE To develop and evaluate an accelerated 3D self-gated cardiac cine imaging technique at 3 Tesla without the use of external electrocardiogram triggering or respiratory gating. METHODS A 3D stack-of-stars balanced steady-state free precession sequence with a tiny golden angle sampling scheme was developed to reduced eddy current effect-related artefacts at 3 Tesla. Respiratory and cardiac motion were derived from a central 5-point self-gating signal extraction approach. The data acquired around the end-expiration phases were then sorted into individual cardiac bins and used for reconstruction with compressed sensing. To evaluate the performance of the proposed method, image quality (1: the best; 4: the worst) was quantitatively compared using both the proposed method and the conventional 3D golden-angle self-gated method. Linear regression and Bland-Altman analysis were used to assess the functional measurements agreement between the proposed method and the routine 2D breath-hold multi-slice technique. RESULTS Compared to the conventional 3D golden-angle self-gated method, the proposed method yielded images with much less streaking artifact and higher myocardium edge sharpness (0.50 ± 0.06 vs. 0.45 ± 0.05, P = 0.004). The proposed method provided an inferior image quality score to the routine 2D technique (2.13 ± 0.35 vs. 1.38 ± 0.52, P = 0.063) but a superior one to the conventional self-gated method (2.13 ± 0.35 vs. 3.13 ± 0.64, P = 0.031). Left ventricular functional measurements between the proposed method and routine 2D technique were all well in agreement. CONCLUSION This study presents a novel self-gating approach to realize rapid 3D cardiac cine imaging at 3 Tesla.
Collapse
Affiliation(s)
- Xiaoyong Zhang
- Centers for Biomedical Engineering, University of Science and Technology of China, Hefei, People's Republic of China.,MR Collaborations NE Asia, Siemens Healthcare, Shenzhen, People's Republic of China
| | - Guoxi Xie
- Paul C. Lauterber Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China.,Guangzhou Medical University, Guangzhou, People's Republic of China
| | - Na Lu
- Guangzhou Medical University, Guangzhou, People's Republic of China
| | - Yanchun Zhu
- Paul C. Lauterber Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China
| | - Zijun Wei
- Paul C. Lauterber Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China
| | - Shi Su
- Paul C. Lauterber Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China
| | - Caiyun Shi
- Paul C. Lauterber Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China
| | - Fei Yan
- Paul C. Lauterber Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China
| | - Xin Liu
- Paul C. Lauterber Research Center for Biomedical Imaging, Institute of Biomedical and Health Engineering, Shenzhen Institutes of Advanced Technology, Chinese Academy of Sciences, Shenzhen, People's Republic of China
| | - Bensheng Qiu
- Centers for Biomedical Engineering, University of Science and Technology of China, Hefei, People's Republic of China
| | - Zhaoyang Fan
- Biomedical Imaging Research Institute, Cedars-Sinai Medical Center, Los Angeles, California.,Departments of Medicine and Bioengineering, University of California, Los Angeles, California
| |
Collapse
|
41
|
Moghari MH, Barthur A, Amaral ME, Geva T, Powell AJ. Free-breathing whole-heart 3D cine magnetic resonance imaging with prospective respiratory motion compensation. Magn Reson Med 2017; 80:181-189. [PMID: 29222852 DOI: 10.1002/mrm.27021] [Citation(s) in RCA: 19] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/20/2017] [Revised: 10/11/2017] [Accepted: 10/31/2017] [Indexed: 12/27/2022]
Abstract
PURPOSE To develop and validate a new prospective respiratory motion compensation algorithm for free-breathing whole-heart 3D cine steady-state free precession (SSFP) imaging. METHODS In a 3D cine SSFP sequence, 4 excitations per cardiac cycle are re-purposed to prospectively track heart position. Specifically, their 1D image is reconstructed and routed into the scanner's standard diaphragmatic navigator processing system. If all 4 signals are in end-expiration, cine image data from the entire cardiac cycle is accepted for image reconstruction. Prospective validation was carried out in patients (N = 17) by comparing in each a conventional breath-hold 2D cine ventricular short-axis stack and a free-breathing whole-heart 3D cine data set. RESULTS All 3D cine SSFP acquisitions were successful and the mean scan time was 5.9 ± 2.7 min. Left and right ventricular end-diastolic, end-systolic, and stroke volumes by 3D cine SSFP were all larger than those from 2D cine SSFP. This bias was < 6% except for right ventricular end-systolic volume that was 12%. The 3D cine images had a lower ventricular blood-to-myocardium contrast ratio, contrast-to-noise ratio, mass, and subjective quality score. CONCLUSION The novel prospective respiratory motion compensation method for 3D cine SSFP imaging was robust and efficient and yielded slightly larger ventricular volumes and lower mass compared to breath-hold 2D cine imaging. Magn Reson Med 80:181-189, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Collapse
Affiliation(s)
- Mehdi H Moghari
- Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts, USA.,Department of Pediatrics, Harvard Medical School, Boston, Massachusetts, USA
| | - Ashita Barthur
- Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts, USA
| | - Maria E Amaral
- Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts, USA
| | - Tal Geva
- Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts, USA.,Department of Pediatrics, Harvard Medical School, Boston, Massachusetts, USA
| | - Andrew J Powell
- Department of Cardiology, Boston Children's Hospital, Boston, Massachusetts, USA.,Department of Pediatrics, Harvard Medical School, Boston, Massachusetts, USA
| |
Collapse
|
42
|
Single-breath-hold 3-D CINE imaging of the left ventricle using Cartesian sampling. MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE 2017; 31:19-31. [DOI: 10.1007/s10334-017-0624-1] [Citation(s) in RCA: 20] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/08/2017] [Revised: 04/19/2017] [Accepted: 05/10/2017] [Indexed: 10/19/2022]
|