1
|
Liu J, Hu W, Han Y, Nie H. Recent advances in mass spectrometry imaging of single cells. Anal Bioanal Chem 2023:10.1007/s00216-023-04774-9. [PMID: 37269305 DOI: 10.1007/s00216-023-04774-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/28/2023] [Revised: 05/18/2023] [Accepted: 05/23/2023] [Indexed: 06/05/2023]
Abstract
Mass spectrometry imaging (MSI) is a sensitive, specific, label-free imaging analysis technique that can simultaneously obtain the spatial distribution, relative content, and structural information of hundreds of biomolecules in cells and tissues, such as lipids, small drug molecules, peptides, proteins, and other compounds. The study of molecular mapping of single cells can reveal major scientific issues such as the activity pattern of living organisms, disease pathogenesis, drug-targeted therapy, and cellular heterogeneity. Applying MSI technology to the molecular mapping of single cells can provide new insights and ideas for the study of single-cell metabolomics. This review aims to provide an informative resource for those in the MSI community who are interested in single-cell imaging. Particularly, we discuss advances in imaging schemes and sample preparation, instrumentation improvements, data processing and analysis, and 3D MSI over the past few years that have allowed MSI to emerge as a powerful technique in the molecular imaging of single cells. Also, we highlight some of the most cutting-edge studies in single-cell MSI, demonstrating the future potential of single-cell MSI. Visualizing molecular distribution at the single-cell or even sub-cellular level can provide us with richer cell information, which strongly contributes to advancing research fields such as biomedicine, life sciences, pharmacodynamic testing, and metabolomics. At the end of the review, we summarize the current development of single-cell MSI technology and look into the future of this technology.
Collapse
Affiliation(s)
- Jikun Liu
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing, 102249, China
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China
- Analytical Instrumental Center, Peking University, Beijing, 100871, China
| | - Wenya Hu
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing, 102249, China
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China
- Analytical Instrumental Center, Peking University, Beijing, 100871, China
| | - Yehua Han
- State Key Laboratory of Heavy Oil Processing, China University of Petroleum, Beijing, 102249, China.
| | - Honggang Nie
- Beijing National Laboratory for Molecular Sciences, College of Chemistry and Molecular Engineering, Peking University, Beijing, 100871, China.
- Analytical Instrumental Center, Peking University, Beijing, 100871, China.
| |
Collapse
|
2
|
Zhu J, Chen J, Amjadian M, Liang S, Qu Z, Wang Y, Zhang Y, Wang L. Simultaneous dual-modal photoacoustic and harmonic ultrasound microscopy with an optimized acoustic combiner. BIOMEDICAL OPTICS EXPRESS 2023; 14:1626-1635. [PMID: 37078044 PMCID: PMC10110316 DOI: 10.1364/boe.484038] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/29/2022] [Revised: 03/01/2023] [Accepted: 03/02/2023] [Indexed: 05/03/2023]
Abstract
Simultaneous photoacoustic (PA) and ultrasound (US) imaging provides rich optical and acoustic contrasts with high sensitivity, specificity, and resolution, making it a promising tool for diagnosing and assessing various diseases. However, the resolution and penetration depth tend to be contradictory due to the increased attenuation of high-frequency ultrasound. To address this issue, we present simultaneous dual-modal PA/US microscopy with an optimized acoustic combiner that can maintain high resolution while improving the penetration of ultrasound imaging. A low-frequency ultrasound transducer is used for acoustic transmission, and a high-frequency transducer is used for PA and US detection. An acoustic beam combiner is utilized to merge the transmitting and receiving acoustic beams with a predetermined ratio. By combining the two different transducers, harmonic US imaging and high-frequency photoacoustic microscopy are implemented. In vivo experiments on the mouse brain demonstrate the simultaneous PA and US imaging ability. The harmonic US imaging of the mouse eye reveals finer iris and lens boundary structures than conventional US imaging, providing a high-resolution anatomical reference for co-registered PA imaging.
Collapse
Affiliation(s)
- Jingyi Zhu
- Department of Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Ave, Kowloon, Hong Kong SAR, China
| | - Jiangbo Chen
- Department of Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Ave, Kowloon, Hong Kong SAR, China
| | - Mohammadreza Amjadian
- Department of Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Ave, Kowloon, Hong Kong SAR, China
- Department of Chemical and Biological Engineering, Hong Kong University of Science and Technology, Clear Water Bay, Kowloon, Hong Kong SAR, China
| | - Siyi Liang
- Department of Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Ave, Kowloon, Hong Kong SAR, China
| | - Zheng Qu
- Department of Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Ave, Kowloon, Hong Kong SAR, China
| | - Yue Wang
- Department of Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Ave, Kowloon, Hong Kong SAR, China
| | - Yachao Zhang
- Department of Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Ave, Kowloon, Hong Kong SAR, China
| | - Lidai Wang
- Department of Biomedical Engineering, City University of Hong Kong, 83 Tat Chee Ave, Kowloon, Hong Kong SAR, China
- City University of Hong Kong Shenzhen Research Institute, Yuexing Yi Dao, Nanshan District, China
| |
Collapse
|
3
|
Jung H, Shung KK, Lim HG. Ultrasonic High-Resolution Imaging and Acoustic Tweezers Using Ultrahigh Frequency Transducer: Integrative Single-Cell Analysis. SENSORS (BASEL, SWITZERLAND) 2023; 23:1916. [PMID: 36850513 PMCID: PMC9962640 DOI: 10.3390/s23041916] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 11/10/2022] [Revised: 02/05/2023] [Accepted: 02/07/2023] [Indexed: 06/18/2023]
Abstract
Ultrasound imaging is a highly valuable tool in imaging human tissues due to its non-invasive and easily accessible nature. Despite advances in the field of ultrasound research, conventional transducers with frequencies lower than 20 MHz face limitations in resolution for cellular applications. To address this challenge, we employed ultrahigh frequency (UHF) transducers and demonstrated their potential applications in the field of biomedical engineering, specifically for cell imaging and acoustic tweezers. The lateral resolution achieved with a 110 MHz UHF transducer was 20 μm, and 6.5 μm with a 410 MHz transducer, which is capable of imaging single cells. The results of our experiments demonstrated the successful imaging of a single PC-3 cell and a 15 μm bead using an acoustic scanning microscope equipped with UHF transducers. Additionally, the dual-mode multifunctional UHF transducer was used to trap and manipulate single cells and beads, highlighting its potential for single-cell studies in areas such as cell deformability and mechanotransduction.
Collapse
Affiliation(s)
- Hayong Jung
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA
| | - K. Kirk Shung
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA
| | - Hae Gyun Lim
- Department of Biomedical Engineering, Pukyong National University, Busan 48513, Republic of Korea
| |
Collapse
|
4
|
Choi W, Park B, Choi S, Oh D, Kim J, Kim C. Recent Advances in Contrast-Enhanced Photoacoustic Imaging: Overcoming the Physical and Practical Challenges. Chem Rev 2023. [PMID: 36642892 DOI: 10.1021/acs.chemrev.2c00627] [Citation(s) in RCA: 24] [Impact Index Per Article: 24.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/17/2023]
Abstract
For decades now, photoacoustic imaging (PAI) has been investigated to realize its potential as a niche biomedical imaging modality. Despite its highly desirable optical contrast and ultrasonic spatiotemporal resolution, PAI is challenged by such physical limitations as a low signal-to-noise ratio (SNR), diminished image contrast due to strong optical attenuation, and a lower-bound on spatial resolution in deep tissue. In addition, contrast-enhanced PAI has faced practical limitations such as insufficient cell-specific targeting due to low delivery efficiency and difficulties in developing clinically translatable agents. Identifying these limitations is essential to the continuing expansion of the field, and substantial advances in developing contrast-enhancing agents, complemented by high-performance image acquisition systems, have synergistically dealt with the challenges of conventional PAI. This review covers the past four years of research on pushing the physical and practical challenges of PAI in terms of SNR/contrast, spatial resolution, targeted delivery, and clinical application. Promising strategies for dealing with each challenge are reviewed in detail, and future research directions for next generation contrast-enhanced PAI are discussed.
Collapse
Affiliation(s)
- Wonseok Choi
- Department of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, Graduate School of Artificial Intelligence, and Medical Device Innovation Center, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang37673, Republic of Korea
| | - Byullee Park
- Department of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, Graduate School of Artificial Intelligence, and Medical Device Innovation Center, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang37673, Republic of Korea
| | - Seongwook Choi
- Department of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, Graduate School of Artificial Intelligence, and Medical Device Innovation Center, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang37673, Republic of Korea
| | - Donghyeon Oh
- Department of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, Graduate School of Artificial Intelligence, and Medical Device Innovation Center, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang37673, Republic of Korea
| | - Jongbeom Kim
- Department of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, Graduate School of Artificial Intelligence, and Medical Device Innovation Center, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang37673, Republic of Korea
| | - Chulhong Kim
- Department of Electrical Engineering, Convergence IT Engineering, Mechanical Engineering, and Medical Science and Engineering, Graduate School of Artificial Intelligence, and Medical Device Innovation Center, Pohang University of Science and Technology, 77 Cheongam-Ro, Nam-Gu, Pohang37673, Republic of Korea
| |
Collapse
|
5
|
Jung U, Ryu J, Choi H. Optical Light Sources and Wavelengths within the Visible and Near-Infrared Range Using Photoacoustic Effects for Biomedical Applications. BIOSENSORS 2022; 12:bios12121154. [PMID: 36551121 PMCID: PMC9775951 DOI: 10.3390/bios12121154] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/11/2022] [Revised: 11/29/2022] [Accepted: 12/02/2022] [Indexed: 06/01/2023]
Abstract
The photoacoustic (PA) effect occurs when sound waves are generated by light according to the thermodynamic and optical properties of the materials; they are absorption spectroscopic techniques that can be applied to characterize materials that absorb pulse or continuous wave (CW)-modulated electromagnetic radiation. In addition, the wavelengths and properties of the incident light significantly impact the signal-to-ratio and contrast with photoacoustic signals. In this paper, we reviewed how absorption spectroscopic research results have been used in applying actual photoacoustic effects, focusing on light sources of each wavelength. In addition, the characteristics and compositions of the light sources used for the applications were investigated and organized based on the absorption spectrum of the target materials. Therefore, we expect that this study will help researchers (who desire to study photoacoustic effects) to more efficiently approach the appropriate conditions or environments for selecting the target materials and light sources.
Collapse
Affiliation(s)
- Unsang Jung
- Production Technology Research Center, Kumoh National Institute of Technology, 61 Daehak-ro, Gumi 39177, Gyeongsangbuk-do, Republic of Korea
| | - Jaemyung Ryu
- Department of Optical Engineering, Kumoh National Institute of Technology, 350-27 Gumi-daero, Gumi 39253, Gyeongsangbuk-do, Republic of Korea
| | - Hojong Choi
- Department of Electronic Engineering, Gachon University, Seongnam-daero, Sujeong-gu, Seongnam 13420, Gyeonggi-do, Republic of Korea
| |
Collapse
|
6
|
Nteroli G, Messa G, Dasa MK, Penttinen A, Härkönen A, Guina M, Podoleanu AG, Koutsikou S, Bradu A. Enhanced resolution optoacoustic microscopy using a picosecond high repetition rate Q-switched microchip laser. JOURNAL OF BIOMEDICAL OPTICS 2022; 27:110501. [PMID: 36458112 PMCID: PMC9705569 DOI: 10.1117/1.jbo.27.11.110501] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/13/2022] [Accepted: 11/04/2022] [Indexed: 06/17/2023]
Abstract
Conventional optoacoustic microscopy (OAM) instruments have at their core a nanosecond pulse duration laser. If lasers with a shorter pulse duration are used, broader, higher frequency ultrasound waves are expected to be generated and as a result, the axial resolution of the instrument is improved. Here, we exploit the advantage offered by a picosecond duration pulse laser to enhance the axial resolution of an OAM instrument. In comparison to an instrument equipped with a 2-ns pulse duration laser, an improvement in the axial resolution of 50% is experimentally demonstrated by using excitation pulses of only 85 ps. To illustrate the capability of the instrument to generate high-quality optoacoustic images, en-face, in-vivo images of the brain of Xenopus laevis tadpole are presented with a lateral resolution of 3.8 μ m throughout the entire axial imaging range.
Collapse
Affiliation(s)
- Gianni Nteroli
- University of Kent, Applied Optics Group, Canterbury, United Kingdom
| | - Giulia Messa
- University of Kent, Medway School of Pharmacy, Chatham, United Kingdom
| | - Manoj K. Dasa
- Technical University of Denmark, DTU Fotonik, Lyngby, Denmark
| | - Antti Penttinen
- Tampere University, Optoelectronics Research Centre, Physics Unit, Faculty of Engineering and Natural Sciences, Tampere, Finland
| | - Antti Härkönen
- Tampere University, Optoelectronics Research Centre, Physics Unit, Faculty of Engineering and Natural Sciences, Tampere, Finland
| | - Mircea Guina
- Tampere University, Optoelectronics Research Centre, Physics Unit, Faculty of Engineering and Natural Sciences, Tampere, Finland
| | | | - Stella Koutsikou
- University of Kent, Medway School of Pharmacy, Chatham, United Kingdom
| | - Adrian Bradu
- University of Kent, Applied Optics Group, Canterbury, United Kingdom
| |
Collapse
|
7
|
Ghanbarzadeh-Dagheyan A, Nili VA, Ejtehadi M, Savabi R, Kavehvash Z, Ahmadian MT, Vahdat BV. Time-domain ultrasound as prior information for frequency-domain compressive ultrasound for intravascular cell detection: A 2-cell numerical model. ULTRASONICS 2022; 125:106791. [PMID: 35809517 DOI: 10.1016/j.ultras.2022.106791] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/21/2021] [Revised: 05/05/2022] [Accepted: 06/08/2022] [Indexed: 06/15/2023]
Abstract
This study proposes a new method for the detection of a weak scatterer among strong scatterers using prior-information ultrasound (US) imaging. A perfect application of this approach is in vivo cell detection in the bloodstream, where red blood cells (RBCs) serve as identifiable strong scatterers. In vivo cell detection can help diagnose cancer at its earliest stages, increasing the chances of survival for patients. This work combines time-domain US with frequency-domain compressive US imaging to detect a 20-μ MCF-7 circulating tumor cell (CTC) among a number of RBCs within a simulated venule inside the mouth. The 2D image reconstructed from the time-domain US is employed to simulate the reflected and scattered pressure field from the RBCs, which is then measured at the location of the receivers. The RBCs are tagged one time by a human operator and another time, automatically, by template-based computer vision. Next, the resulting signal from the RBCs is subtracted from the measured total signal in frequency domain to generate the scattered-field data, coming from the CTC alone. Feeding that signal and the background pressure field into a norm-one-based compressive sensing code enables detecting the CTC at various locations. As errors could arise in determining the location of the RBCs and their acoustic properties in the real world, small errors (up to 10% in the former and 5% in the latter) are purposefully introduced to the model, to which the proposed method is shown to be resilient. Localization errors are smaller than 12 μ when a human tags the RBCs and smaller than 25 μ when computer vision is applied. Despite its limitations, this study, for the first time, reports the results of combining two US modalities aimed at cell detection and introduces a unique and useful application for ultrahigh-frequency US imaging. It should be noted that this method can be used in detecting weak scatterers with ultrasound waves in other applications as well.
Collapse
Affiliation(s)
- Ashkan Ghanbarzadeh-Dagheyan
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran; Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran.
| | - Vahid Amin Nili
- Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran
| | - Mehdi Ejtehadi
- Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran
| | - Reza Savabi
- School of Mechanical Engineering, University of Tehran, Tehran, Iran
| | - Zahra Kavehvash
- Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran
| | | | | |
Collapse
|
8
|
Balasubramanian PS, Lal A. GHz Ultrasound and Electrode Chip-Scale Arrays Stimulate and Influence Morphology of Human Neural Cells. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2022; 69:1898-1909. [PMID: 35180080 DOI: 10.1109/tuffc.2022.3152427] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
This study describes the effects of chip-scale gigahertz (GHz) ultrasound (US) and electrical stimulus on the morphology, functionality, and viability of neural cells in vitro. The GHz frequency stimulation is achieved using aluminum nitride piezoelectric transducers fabricated on a silicon wafer, operating at 1.47 GHz, corresponding to the film's thickness mode resonance. These devices are used to stimulate SH-SY5Y neural cells in vitro and observe effects on the morphology and viability of the stimulated cells. It is possible to use these devices to deliver either ultrasonic stimulus alone or US stimulus in conjunction with electrical stimulus. Viability tests demonstrated that the neurons retained structural integrity and viability across a wide range of GHz US stimulus intensities (0-1.2 W/cm2), validating that measurements occur at nontoxic doses of US. Neural stimulation is validated with these devices following the outputs of a previous study, with the normalized fluorescence intensity of activated cells between 1.9 and 2.4. The 300-s ultrasonic stimulation at 1.47 GHz and 0.05 W/cm2 peak intensity led to a decrease in nuclear elongation by 17.5% and a cross-sectional area decrease by 17.8% across three independent trials of over 150 cells per category ( ). The F-actin governed cellular elongation increased in length by up to 16.3% in cells exposed to an ultrasonic stimulus or costimulus ( ). Neurite length increased following ultrasonic stimulation compared with control by 75.8% ( ). This article demonstrates new GHz US and electrical chip-scale arrays with apparent effects in both neural excitation and cell morphology.
Collapse
|
9
|
Figarol A, Olive L, Joubert O, Ferrari L, Rihn BH, Sarry F, Beyssen D. Biological Effects and Applications of Bulk and Surface Acoustic Waves on In Vitro Cultured Mammal Cells: New Insights. Biomedicines 2022; 10:biomedicines10051166. [PMID: 35625902 PMCID: PMC9139135 DOI: 10.3390/biomedicines10051166] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/14/2022] [Revised: 05/09/2022] [Accepted: 05/13/2022] [Indexed: 02/01/2023] Open
Abstract
Medical imaging has relied on ultrasound (US) as an exploratory method for decades. Nonetheless, in cell biology, the numerous US applications are mainly in the research and development phase. In this review, we report the main effects on human or mammal cells of US induced by bulk or surface acoustic waves (SAW). At low frequencies, bulk US can lead to cell death. Under specific intensities and exposure times, however, cell proliferation and migration can be enhanced through cytoskeleton fluidization (a reorganization of the actin filaments and microtubules). Cavitation phenomena, frequencies of resonance close to those of the biological compounds, and mechanical transfers of energy from the acoustic pressure could explain those biological outcomes. At higher frequencies, no cavitation is observed. However, USs of high frequency stimulate ionic channels and increase cell permeability and transfection potency. Surface acoustic waves are increasingly exploited in microfluidics, especially for precise cell manipulations and cell sorting. With applications in diagnosis, infection, cancer treatment, or wound healing, US has remarkable potential. More mechanotransduction studies would be beneficial to understand the distinct roles of temperature rise, acoustic streaming and mechanical and electrical stimuli in the field.
Collapse
Affiliation(s)
- Agathe Figarol
- Institut FEMTO-ST, UMR CNRS 6174, Université de Bourgogne Franche-Comté, F-25030 Besançon, France;
- Institut Jean Lamour, UMR CNRS 7198, Université de Lorraine, CNRS, IJL, F-54000 Nancy, France; (L.O.); (O.J.); (L.F.); (B.H.R.); (F.S.)
| | - Lucile Olive
- Institut Jean Lamour, UMR CNRS 7198, Université de Lorraine, CNRS, IJL, F-54000 Nancy, France; (L.O.); (O.J.); (L.F.); (B.H.R.); (F.S.)
| | - Olivier Joubert
- Institut Jean Lamour, UMR CNRS 7198, Université de Lorraine, CNRS, IJL, F-54000 Nancy, France; (L.O.); (O.J.); (L.F.); (B.H.R.); (F.S.)
| | - Luc Ferrari
- Institut Jean Lamour, UMR CNRS 7198, Université de Lorraine, CNRS, IJL, F-54000 Nancy, France; (L.O.); (O.J.); (L.F.); (B.H.R.); (F.S.)
| | - Bertrand H. Rihn
- Institut Jean Lamour, UMR CNRS 7198, Université de Lorraine, CNRS, IJL, F-54000 Nancy, France; (L.O.); (O.J.); (L.F.); (B.H.R.); (F.S.)
| | - Frédéric Sarry
- Institut Jean Lamour, UMR CNRS 7198, Université de Lorraine, CNRS, IJL, F-54000 Nancy, France; (L.O.); (O.J.); (L.F.); (B.H.R.); (F.S.)
| | - Denis Beyssen
- Institut Jean Lamour, UMR CNRS 7198, Université de Lorraine, CNRS, IJL, F-54000 Nancy, France; (L.O.); (O.J.); (L.F.); (B.H.R.); (F.S.)
- Correspondence: ; Tel.: +33-61-448-6182
| |
Collapse
|
10
|
A Wideband Noise and Harmonic Distortion Canceling Low-Noise Amplifier for High-Frequency Ultrasound Transducers. SENSORS 2021; 21:s21248476. [PMID: 34960568 PMCID: PMC8703952 DOI: 10.3390/s21248476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/16/2021] [Revised: 12/11/2021] [Accepted: 12/17/2021] [Indexed: 12/03/2022]
Abstract
This paper presents a wideband low-noise amplifier (LNA) front-end with noise and distortion cancellation for high-frequency ultrasound transducers. The LNA employs a resistive shunt-feedback structure with a feedforward noise-canceling technique to accomplish both wideband impedance matching and low noise performance. A complementary CMOS topology was also developed to cancel out the second-order harmonic distortion and enhance the amplifier linearity. A high-frequency ultrasound (HFUS) and photoacoustic (PA) imaging front-end, including the proposed LNA and a variable gain amplifier (VGA), was designed and fabricated in a 180 nm CMOS process. At 80 MHz, the front-end achieves an input-referred noise density of 1.36 nV/sqrt (Hz), an input return loss (S11) of better than −16 dB, a voltage gain of 37 dB, and a total harmonic distortion (THD) of −55 dBc while dissipating a power of 37 mW, leading to a noise efficiency factor (NEF) of 2.66.
Collapse
|
11
|
Alcoholic Fermentation Monitoring and pH Prediction in Red and White Wine by Combining Spontaneous Raman Spectroscopy and Machine Learning Algorithms. BEVERAGES 2021. [DOI: 10.3390/beverages7040078] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
In the following study, total sugar concentrations before and during alcoholic fermentation, as well as ethanol concentrations and pH levels after fermentation, of red and white wine grapes were successfully predicted using Raman spectroscopy. Fluorescing compounds such as anthocyanins and pigmented phenolics found in red wine present one of the primary limitations of enological analysis using Raman spectroscopy. Unlike the spontaneous Raman effect, fluorescence is a highly efficient process and consequently emits a much stronger signal than spontaneous Raman scattering. For this reason, many enological applications of Raman spectroscopy are impractical as the more subtle Raman spectrum of any red wine sample is in large part masked by fluorescing compounds present in the wine. This work employs a simple extraction method to mitigate fluorescence in finished red wines. Ethanol and total sugars (fructose plus glucose) of wines made from red (Cabernet Sauvignon) and white (Chardonnay, Sauvignon Blanc, and Gruner Veltliner) varieties were modeled using support vector regression (SVR), partial least squares regression (PLSR) and Ridge regression (RR). The results, which compared the predicted to measured total sugar concentrations before and during fermentation, were excellent (R2SVR = 0.96, R2PLSR = 0.95, R2RR = 0.95, RMSESVR = 1.59, RMSEPLSR = 1.57, RMSERR = 1.57), as were the ethanol and pH predictions for finished wines after phenolic stripping with polyvinylpolypyrrolidone (R2SVR = 0.98, R2PLSR = 0.99, R2RR = 0.99, RMSESVR = 0.23, RMSEPLSR = 0.21, RMSERR = 0.23). The results suggest that Raman spectroscopy is a viable tool for rapid and trustworthy fermentation monitoring.
Collapse
|
12
|
Zheng BD, Ye J, Huang YY, Xiao MT. Phthalocyanine-based photoacoustic contrast agents for imaging and theranostics. Biomater Sci 2021; 9:7811-7825. [PMID: 34755723 DOI: 10.1039/d1bm01435h] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Abstract
Phthalocyanine, as an organic dye, has attracted much attention due to its high molar absorption coefficient in the near-infrared region (NIR). It is precisely because of this advantage that phthalocyanine is very beneficial to photoacoustic imaging (PAI). At present, many different strategies have been adopted to design phthalocyanine-based contrast agents with photoacoustic (PA) effect, including increasing water solubility, changing spectral properties, prolonging the circulation time, constructing activatable supramolecular nanoparticles, increasing targeting, etc. Based on this, this minireview highlighted the above ways to enhance the PA effect of phthalocyanine. What's more, the application of phthalocyanine-based PA contrast agents in biomedical imaging and image-guided phototherapy has been discussed. Finally, this minireview also provides the prospects and challenges of phthalocyanine-based PA contrast agents in order to provide some reference for the application of phthalocyanine-based PA contrast agents in biomedical imaging and guiding tumor treatment.
Collapse
Affiliation(s)
- Bing-De Zheng
- College of Chemical Engineering, Huaqiao University, Xiamen 361021, China.
| | - Jing Ye
- College of Chemical Engineering, Huaqiao University, Xiamen 361021, China.
| | - Ya-Yan Huang
- College of Chemical Engineering, Huaqiao University, Xiamen 361021, China.
| | - Mei-Tian Xiao
- College of Chemical Engineering, Huaqiao University, Xiamen 361021, China.
| |
Collapse
|
13
|
Park S, Nguyen T, Benoit E, Sackett DL, Garmendia-Cedillos M, Pursley R, Boccara C, Gandjbakhche A. Quantitative evaluation of the dynamic activity of HeLa cells in different viability states using dynamic full-field optical coherence microscopy. BIOMEDICAL OPTICS EXPRESS 2021; 12:6431-6441. [PMID: 34745747 PMCID: PMC8548024 DOI: 10.1364/boe.436330] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/09/2021] [Revised: 08/13/2021] [Accepted: 08/13/2021] [Indexed: 05/30/2023]
Abstract
Dynamic full-field optical coherence microscopy (DFFOCM) was used to characterize the intracellular dynamic activities and cytoskeleton of HeLa cells in different viability states. HeLa cell samples were continuously monitored for 24 hours and compared with histological examination to confirm the cell viability states. The averaged mean frequency and magnitude observed in healthy cells were 4.79±0.5 Hz and 2.44±1.06, respectively. In dead cells, the averaged mean frequency was shifted to 8.57±0.71 Hz, whereas the magnitude was significantly decreased to 0.53±0.25. This cell dynamic activity analysis using DFFOCM is expected to replace conventional time-consuming and biopsies-required histological or biochemical methods.
Collapse
Affiliation(s)
- Soongho Park
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Dr., Bethesda 20814, USA
| | - Thien Nguyen
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Dr., Bethesda 20814, USA
| | - Emilie Benoit
- LLTech SAS-Aquyre Biosciences, 58 Rue du Dessous des Berges, 75013 Paris, France
| | - Dan L. Sackett
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Dr., Bethesda 20814, USA
| | - Marcial Garmendia-Cedillos
- The Signal Processing and Instrumentation Section, Center for Information Technology, National Institutes of Health, 49 Convent Dr., Bethesda 20814, USA
| | - Randall Pursley
- The Signal Processing and Instrumentation Section, Center for Information Technology, National Institutes of Health, 49 Convent Dr., Bethesda 20814, USA
| | - Claude Boccara
- LLTech SAS-Aquyre Biosciences, 58 Rue du Dessous des Berges, 75013 Paris, France
- Institut Langevin, ESPCI Paris, CNRS, PSL University, 1 rue Jussieu, 75005 Paris, France
| | - Amir Gandjbakhche
- Eunice Kennedy Shriver National Institute of Child Health and Human Development, National Institutes of Health, 49 Convent Dr., Bethesda 20814, USA
| |
Collapse
|
14
|
La Cavera S, Pérez-Cota F, Smith RJ, Clark M. Phonon imaging in 3D with a fibre probe. LIGHT, SCIENCE & APPLICATIONS 2021; 10:91. [PMID: 33907178 PMCID: PMC8079419 DOI: 10.1038/s41377-021-00532-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Revised: 03/30/2021] [Accepted: 04/07/2021] [Indexed: 05/07/2023]
Abstract
We show for the first time that a single ultrasonic imaging fibre is capable of simultaneously accessing 3D spatial information and mechanical properties from microscopic objects. The novel measurement system consists of two ultrafast lasers that excite and detect high-frequency ultrasound from a nano-transducer that was fabricated onto the tip of a single-mode optical fibre. A signal processing technique was also developed to extract nanometric in-depth spatial measurements from GHz frequency acoustic waves, while still allowing Brillouin spectroscopy in the frequency domain. Label-free and non-contact imaging performance was demonstrated on various polymer microstructures. This singular device is equipped with optical lateral resolution, 2.5 μm, and a depth-profiling precision of 45 nm provided by acoustics. The endoscopic potential for this device is exhibited by extrapolating the single fibre to tens of thousands of fibres in an imaging bundle. Such a device catalyses future phonon endomicroscopy technology that brings the prospect of label-free in vivo histology within reach.
Collapse
Affiliation(s)
- Salvatore La Cavera
- Optics and Photonics Group, Faculty of Engineering, University of Nottingham, University Park, Nottingham, NG7 2RD, UK.
| | - Fernando Pérez-Cota
- Optics and Photonics Group, Faculty of Engineering, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Richard J Smith
- Optics and Photonics Group, Faculty of Engineering, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| | - Matt Clark
- Optics and Photonics Group, Faculty of Engineering, University of Nottingham, University Park, Nottingham, NG7 2RD, UK
| |
Collapse
|
15
|
Smith RJ, Pérez-Cota F, Marques L, Clark M. 3D phonon microscopy with sub-micron axial-resolution. Sci Rep 2021; 11:3301. [PMID: 33558575 PMCID: PMC7870650 DOI: 10.1038/s41598-021-82639-w] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2020] [Accepted: 01/18/2021] [Indexed: 12/12/2022] Open
Abstract
Brillouin light scattering (BLS) is an emerging method for cell imaging and characterisation. It allows elasticity-related contrast, optical resolution and label-free operation. Phonon microscopy detects BLS from laser generated coherent phonon fields to offer an attractive route for imaging since, at GHz frequencies, the phonon wavelength is sub-optical. Using phonon fields to image single cells is challenging as the signal to noise ratio and acquisition time are often poor. However, recent advances in the instrumentation have enabled imaging of fixed and living cells. This work presents the first experimental characterisation of phonon-based axial resolution provided by the response to a sharp edge. The obtained axial resolution is up to 10 times higher than that of the optical system used to take the measurements. Validation of the results are obtained with various polymer objects, which are in good agreement with those obtained using atomic force microscopy. Edge localisation, and hence profilometry, of a phantom boundary is measured with accuracy and precision of approximately 60 nm and 100 nm respectively. Finally, 3D imaging of fixed cells in culture medium is demonstrated.
Collapse
Affiliation(s)
- Richard J Smith
- Optics and Photonics, Faculty of Engineering, University of Nottingham, University Park, Nottingham, UK.
| | - Fernando Pérez-Cota
- Optics and Photonics, Faculty of Engineering, University of Nottingham, University Park, Nottingham, UK
| | - Leonel Marques
- Optics and Photonics, Faculty of Engineering, University of Nottingham, University Park, Nottingham, UK
| | - Matt Clark
- Optics and Photonics, Faculty of Engineering, University of Nottingham, University Park, Nottingham, UK
| |
Collapse
|
16
|
Ecclestone BR, Bell K, Abbasi S, Dinakaran D, Taher M, Mackey JR, Haji Reza P. Histopathology for Mohs micrographic surgery with photoacoustic remote sensing microscopy. BIOMEDICAL OPTICS EXPRESS 2021; 12:654-665. [PMID: 33659093 PMCID: PMC7899511 DOI: 10.1364/boe.405869] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/20/2020] [Revised: 10/30/2020] [Accepted: 11/18/2020] [Indexed: 05/04/2023]
Abstract
Mohs micrographic surgery (MMS) is a precise oncological technique where layers of tissue are resected and examined with intraoperative histopathology to minimize the removal of normal tissue while completely excising the cancer. To achieve intraoperative pathology, the tissue is frozen, sectioned and stained over a 20- to 60-minute period, then analyzed by the MMS surgeon. Surgery is continued one layer at a time until no cancerous cells remain, meaning MMS can take several hours to complete. Ideally, it would be desirable to circumvent or augment frozen sectioning methods and directly visualize subcellular morphology on the unprocessed excised tissues. Employing photoacoustic remote sensing (PARS) microscopy, we present a non-contact label-free reflection-mode method of performing such visualizations in frozen sections of human skin. PARS leverages endogenous optical absorption contrast within cell nuclei to provide visualizations reminiscent of histochemical staining techniques. Presented here, is the first true one to one comparison between PARS microscopy and standard histopathological imaging in human tissues. We demonstrate the ability of PARS microscopy to provide large grossing scans (>1 cm2, sufficient to visualize entire MMS sections) and regional scans with subcellular lateral resolution (300 nm).
Collapse
Affiliation(s)
- Benjamin R. Ecclestone
- PhotoMedicine Labs, Department of Systems Design Engineering, University of Waterloo, 200 University Ave W, Waterloo, Ontario, N2L 3G1, Canada
| | - Kevan Bell
- PhotoMedicine Labs, Department of Systems Design Engineering, University of Waterloo, 200 University Ave W, Waterloo, Ontario, N2L 3G1, Canada
- illumiSonics, Inc., Department of Systems Design Engineering, University of Waterloo, 200 University Ave W, Waterloo, Ontario, N2L 3G1, Canada
| | - Saad Abbasi
- PhotoMedicine Labs, Department of Systems Design Engineering, University of Waterloo, 200 University Ave W, Waterloo, Ontario, N2L 3G1, Canada
| | - Deepak Dinakaran
- illumiSonics, Inc., Department of Systems Design Engineering, University of Waterloo, 200 University Ave W, Waterloo, Ontario, N2L 3G1, Canada
- Department of Oncology, University of Alberta, 8440 112 St. NW, T6G 2R7, Edmonton, Alberta, Canada
| | - Muba Taher
- Division of Dermatology, Department of Medicine, University of Alberta, 116 St & 85 Ave, Edmonton, Alberta, T6G 2V1, Canada
| | - John R. Mackey
- illumiSonics, Inc., Department of Systems Design Engineering, University of Waterloo, 200 University Ave W, Waterloo, Ontario, N2L 3G1, Canada
- Department of Oncology, University of Alberta, 8440 112 St. NW, T6G 2R7, Edmonton, Alberta, Canada
| | - Parsin Haji Reza
- PhotoMedicine Labs, Department of Systems Design Engineering, University of Waterloo, 200 University Ave W, Waterloo, Ontario, N2L 3G1, Canada
| |
Collapse
|
17
|
Golubewa L, Timoshchenko I, Romanov O, Karpicz R, Kulahava T, Rutkauskas D, Shuba M, Dementjev A, Svirko Y, Kuzhir P. Single-walled carbon nanotubes as a photo-thermo-acoustic cancer theranostic agent: theory and proof of the concept experiment. Sci Rep 2020; 10:22174. [PMID: 33335210 PMCID: PMC7746693 DOI: 10.1038/s41598-020-79238-6] [Citation(s) in RCA: 13] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Accepted: 12/07/2020] [Indexed: 02/07/2023] Open
Abstract
Theranostics is the emerging field of medicine that uniquely combines diagnostic techniques and active agents to diagnose and treat medical conditions simultaneously or sequentially. Finding a theranostic agent capable to cure the affected cells and being safe for the healthy ones is the key for successful treatment. Here, we demonstrate that agglomerated single-walled carbon nanotubes (SWCNTs) are promising theranostic agent that enables photo-activated ‘cold’ destruction of the cancer cells keeping their environment alive. The absorption of picosecond pulses by SWCNT agglomerates results in the mechanical (due to photoacoustic effect) rather than photothermal cancer cell destruction, which was visualized by micro-Raman and ultrafast near-infrared CARS. The developed theoretical model allows us to distinguish photothermal, photoacoustic, and photothermoacoustic regimes of the cancer cell destruction, and also to optimize SWCNT-based theranostics recipe.
Collapse
Affiliation(s)
- L Golubewa
- Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257, Vilnius, Lithuania. .,Institute for Nuclear Problems, Belarusian State University, Bobruiskaya 11, 220006, Minsk, Belarus.
| | - I Timoshchenko
- Belarusian State University, Nezavisimosti Ave. 4, 220030, Minsk, Belarus
| | - O Romanov
- Belarusian State University, Nezavisimosti Ave. 4, 220030, Minsk, Belarus
| | - R Karpicz
- Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257, Vilnius, Lithuania
| | - T Kulahava
- Institute for Nuclear Problems, Belarusian State University, Bobruiskaya 11, 220006, Minsk, Belarus.,Belarusian State University, Nezavisimosti Ave. 4, 220030, Minsk, Belarus
| | - D Rutkauskas
- Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257, Vilnius, Lithuania
| | - M Shuba
- Institute for Nuclear Problems, Belarusian State University, Bobruiskaya 11, 220006, Minsk, Belarus.,Tomsk State University, Lenin Ave. 36, Tomsk, Russia, 634050
| | - A Dementjev
- Center for Physical Sciences and Technology, Sauletekio Ave. 3, 10257, Vilnius, Lithuania
| | - Yu Svirko
- Institute of Photonics, University of Eastern Finland, Yliopistokatu 7, 80100, Joensuu, Finland
| | - P Kuzhir
- Institute for Nuclear Problems, Belarusian State University, Bobruiskaya 11, 220006, Minsk, Belarus.,Institute of Photonics, University of Eastern Finland, Yliopistokatu 7, 80100, Joensuu, Finland
| |
Collapse
|
18
|
Dadkhah A, Jiao S. Integrating photoacoustic microscopy with other imaging technologies for multimodal imaging. Exp Biol Med (Maywood) 2020; 246:771-777. [PMID: 33297735 DOI: 10.1177/1535370220977176] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022] Open
Abstract
As a hybrid optical microscopic imaging technology, photoacoustic microscopy images the optical absorption contrasts and takes advantage of low acoustic scattering of biological tissues to achieve high-resolution anatomical and functional imaging. When combined with other imaging modalities, photoacoustic microscopy-based multimodal technologies can provide complementary contrast mechanisms to reveal complementary information of biological tissues. To achieve intrinsically and precisely registered images in a multimodal photoacoustic microscopy imaging system, either the ultrasonic transducer or the light source can be shared among the different imaging modalities. These technologies are the major focus of this minireview. It also covered the progress of the recently developed penta-modal photoacoustic microscopy imaging system featuring a novel dynamic focusing technique enabled by OCT contour scan.
Collapse
Affiliation(s)
- Arash Dadkhah
- Department of Biomedical Engineering, Florida International University, Miami, FL 33174, USA
| | - Shuliang Jiao
- Department of Biomedical Engineering, Florida International University, Miami, FL 33174, USA
| |
Collapse
|
19
|
Shamekhi S, Periyasamy V, Pramanik M, Mehrmohammadi M, Mohammadzadeh Asl B. Eigenspace-based minimum variance beamformer combined with sign coherence factor: Application to linear-array photoacoustic imaging. ULTRASONICS 2020; 108:106174. [PMID: 32502893 DOI: 10.1016/j.ultras.2020.106174] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/26/2019] [Revised: 04/16/2020] [Accepted: 05/12/2020] [Indexed: 06/11/2023]
Abstract
Photoacoustic (PA) imaging combining the advantages of high resolution of ultrasound imaging and high contrast of optical imaging provides images with good quality. PA imaging often suffers from disadvantages such as clutter noises and decreased signal-to-noise-ratio at higher depths. One studied method to reduce clutter noises is to use weighting factors such as coherence factor (CF) and its modified versions that improve resolution and contrast of images. In this study, we combined the Eigen-space based minimum variance (EIBMV) beamformer with the sign coherence factor (SCF) and show the ability of these methods for noise reduction when they are used in combination with each other. In addition, we compared the proposed method with delay-and-sum (DAS) and minimum variance (MV) beamformers in simulated and experimental studies. The simulation results show that the proposed EIBMV-SCF method improves the SNR about 94 dB, 87.65 dB, and 62.29 dB compared to the DAS, MV, and EIBMV, respectively, and the corresponding improvements were 79.37/34.43 dB, 77.25/26.96 dB, and 33.19/25.56 dB in the ex vivo/in vivo experiments.
Collapse
Affiliation(s)
- Sadaf Shamekhi
- Department of Biomedical Engineering, Tarbiat Modares University, Tehran, Iran
| | - Vijitha Periyasamy
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore
| | - Manojit Pramanik
- School of Chemical and Biomedical Engineering, Nanyang Technological University, Singapore
| | | | | |
Collapse
|
20
|
Wang Z, Yang F, Ma H, Cheng Z, Yang S. Photoacoustic and ultrasound (PAUS) dermoscope with high sensitivity and penetration depth by using a bimorph transducer. JOURNAL OF BIOPHOTONICS 2020; 13:e202000145. [PMID: 32506704 DOI: 10.1002/jbio.202000145] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 05/29/2020] [Accepted: 06/02/2020] [Indexed: 06/11/2023]
Abstract
A bimorph transducer was proposed to improve the detection sensitivity and imaging depth of photoacoustic and ultrasound (PAUS) dermoscope. By applying the bimorph transducer, the imaging depth and sensitivity of PAUS dermoscope were enhanced by simultaneously improving excitation efficiency and reception bandwidth. The integrated design of the imaging head of the dermoscope makes it highly convenient for detecting human skin. The PAUS imaging performance was demonstrated via visualizing subcutaneous tumor and depicting full structures of different skin layers from epidermis to subcutaneous tissue. The results confirm that the dermoscope with the bimorph transducer is well suited for PA and US dual-modality imaging, which can provide multi-information for skin disease.
Collapse
Affiliation(s)
- Zhiyang Wang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
| | - Fei Yang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
| | - Haigang Ma
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
| | - Zhongwen Cheng
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
| | - Sihua Yang
- MOE Key Laboratory of Laser Life Science & Institute of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
- Guangdong Provincial Key Laboratory of Laser Life Science, College of Biophotonics, South China Normal University, Guangzhou, China
| |
Collapse
|
21
|
Abstract
Abstract
Purpose
Photoacoustic (PA) microscopy has emerged as a useful tool in biomedical imaging applications such as visualization of microvasculature and hemoglobin oxygen saturation, single-cell, and label-free imaging of organs including cancer. Since the ultrasound transducers used for PA signal detection are not optically transparent, the integration of optical and acoustic modules for coaxial alignment of laser and acoustic beam fields in PA microscopy is complex and costly.
Methods
Here, we report a recently developed optically transparent focused transducer for combined PA and ultrasound (US) microscopy. All the acoustic layers including the acoustic lens are optically transparent, enabling simple integration of optical and acoustic modules for both imaging modalities.
Results
The mean light transmittance of the transducer’s backing layer and acoustic lens and of the transducer itself were measured at 92%, 83%, and 66%, respectively. Results from in vitro and in vivo experiments demonstrated the transducer to be suitable for both US and PA imaging.
Conclusions
The results of this study represent a step toward efficient construction of probes for combined PA and US microscopy.
Collapse
|
22
|
GHz Ultrasonic Chip-Scale Device Induces Ion Channel Stimulation in Human Neural Cells. Sci Rep 2020; 10:3075. [PMID: 32080204 PMCID: PMC7033194 DOI: 10.1038/s41598-020-58133-0] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2019] [Accepted: 01/10/2020] [Indexed: 01/07/2023] Open
Abstract
Emergent trends in the device development for neural prosthetics have focused on establishing stimulus localization, improving longevity through immune compatibility, reducing energy re-quirements, and embedding active control in the devices. Ultrasound stimulation can single-handedly address several of these challenges. Ultrasonic stimulus of neurons has been studied extensively from 100 kHz to 10 MHz, with high penetration but less localization. In this paper, a chip-scale device consisting of piezoelectric Aluminum Nitride ultrasonic transducers was engineered to deliver gigahertz (GHz) ultrasonic stimulus to the human neural cells. These devices provide a path towards complementary metal oxide semiconductor (CMOS) integration towards fully controllable neural devices. At GHz frequencies, ultrasonic wavelengths in water are a few microns and have an absorption depth of 10-20 µm. This confinement of energy can be used to control stimulation volume within a single neuron. This paper is the first proof-of-concept study to demonstrate that GHz ultrasound can stimulate neurons in vitro. By utilizing optical calcium imaging, which records calcium ion flux indicating occurrence of an action potential, this paper demonstrates that an application of a nontoxic dosage of GHz ultrasonic waves [Formula: see text] caused an average normalized fluorescence intensity recordings >1.40 for the calcium transients. Electrical effects due to chip-scale ultrasound delivery was discounted as the sole mechanism in stimulation, with effects tested at α = 0.01 statistical significance amongst all intensities and con-trol groups. Ionic transients recorded optically were confirmed to be mediated by ion channels and experimental data suggests an insignificant thermal contributions to stimulation, with a predicted increase of 0.03 oC for [Formula: see text] This paper paves the experimental framework to further explore chip-scale axon and neuron specific neural stimulation, with future applications in neural prosthetics, chip scale neural engineering, and extensions to different tissue and cell types.
Collapse
|
23
|
Morisaku T, Onuki H, Hashimoto K, Kuchitsu K, Yui H. Development of a Near-infrared Laser-induced Surface Deformation Microscope and Its Application to the Dynamic Viscoelastic Measurements of Single Living Plant Cell Surfaces. ANAL SCI 2019; 35:1203-1207. [PMID: 31308300 DOI: 10.2116/analsci.19p227] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
A near-infrared laser-induced surface deformation (NIR-LISD) microscope is developed and is applied to the dynamic viscoelastic measurements of the surface of a living plant cell. In the microscope, the deformation of the surface is induced by an NIR laser beam, and then the change in intensity of the probe beam reflected from the surface reflects its viscoelasticity. The application of the NIR laser beam has a great advantage for the prevention of damage to the plant cell compared to the irradiation of a visible laser beam in LISD measurements. The NIR-LISD microscope allows for discriminating the differences in power spectra between the subapical and lateral regions of single rhizoids. It is a useful method for the dynamic viscoelastic measurements of cells, such as plant cells, that are damaged due to the strong absorption of ultraviolet or visible light.
Collapse
Affiliation(s)
- Toshinori Morisaku
- Water Frontier Science & Technology Research Center, Research Institute for Science & Technology, Tokyo University of Science
| | - Hitomi Onuki
- Department of Chemistry, Faculty of Science, Tokyo University of Science
| | - Kenji Hashimoto
- Department of Applied Biological Science, Faculty of Science and Technology, Tokyo University of Science
| | - Kazuyuki Kuchitsu
- Department of Applied Biological Science, Faculty of Science and Technology, Tokyo University of Science.,Imaging Frontier Center, Research Institute for Science & Technology, Tokyo University of Science
| | - Hiroharu Yui
- Water Frontier Science & Technology Research Center, Research Institute for Science & Technology, Tokyo University of Science.,Department of Chemistry, Faculty of Science, Tokyo University of Science
| |
Collapse
|
24
|
Vu T, Razansky D, Yao J. Listening to tissues with new light: recent technological advances in photoacoustic imaging. JOURNAL OF OPTICS (2010) 2019; 21:10.1088/2040-8986/ab3b1a. [PMID: 32051756 PMCID: PMC7015182 DOI: 10.1088/2040-8986/ab3b1a] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
Photoacoustic tomography (PAT), or optoacoustic tomography, has achieved remarkable progress in the past decade, benefiting from the joint developments in optics, acoustics, chemistry, computing and mathematics. Unlike pure optical or ultrasound imaging, PAT can provide unique optical absorption contrast as well as widely scalable spatial resolution, penetration depth and imaging speed. Moreover, PAT has inherent sensitivity to tissue's functional, molecular, and metabolic state. With these merits, PAT has been applied in a wide range of life science disciplines, and has enabled biomedical research unattainable by other imaging methods. This Review article aims at introducing state-of-the-art PAT technologies and their representative applications. The focus is on recent technological breakthroughs in structural, functional, molecular PAT, including super-resolution imaging, real-time small-animal whole-body imaging, and high-sensitivity functional/molecular imaging. We also discuss the remaining challenges in PAT and envisioned opportunities.
Collapse
Affiliation(s)
- Tri Vu
- Photoacoustic Imaging Lab, Department of Biomedical Engineering, Duke University, Durham, NC, USA
| | - Daniel Razansky
- Faculty of Medicine and Institute of Pharmacology and Toxicology, University of Zurich, Switzerland
- Institute for Biomedical Engineering and Department of Information Technology and Electrical Engineering, ETH Zurich, Switzerland
| | - Junjie Yao
- Photoacoustic Imaging Lab, Department of Biomedical Engineering, Duke University, Durham, NC, USA
| |
Collapse
|
25
|
Deán-Ben XL, Razansky D. Optoacoustic image formation approaches-a clinical perspective. Phys Med Biol 2019; 64:18TR01. [PMID: 31342913 DOI: 10.1088/1361-6560/ab3522] [Citation(s) in RCA: 18] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/18/2023]
Abstract
Clinical translation of optoacoustic imaging is fostered by the rapid technical advances in imaging performance as well as the growing number of clinicians recognizing the immense diagnostic potential of this technology. Clinical optoacoustic systems are available in multiple configurations, including hand-held and endoscopic probes as well as raster-scan approaches. The hardware design must be adapted to the accessible portion of the imaged region and other application-specific requirements pertaining the achievable depth, field of view or spatio-temporal resolution. Equally important is the adequate choice of the signal and image processing approach, which is largely responsible for the resulting imaging performance. Thus, new image reconstruction algorithms are constantly evolving in parallel to the newly-developed set-ups. This review focuses on recent progress on optoacoustic image formation algorithms and processing methods in the clinical setting. Major reconstruction challenges include real-time image rendering in two and three dimensions, efficient hybridization with other imaging modalitites as well as accurate interpretation and quantification of bio-markers, herein discussed in the context of ongoing progress in clinical translation.
Collapse
Affiliation(s)
- Xosé Luís Deán-Ben
- Faculty of Medicine and Institute of Pharmacology and Toxicology, University of Zurich, Zurich, Switzerland. Department of Information Technology and Electrical Engineering and Institute for Biomedical Engineering, ETH Zurich, Zurich, Switzerland
| | | |
Collapse
|
26
|
Radiological assessment of effectiveness of soluble RAGE in attenuating Angiotensin II-induced LVH mouse model using in vivo 9.4T MRI. Sci Rep 2019; 9:8475. [PMID: 31186521 PMCID: PMC6559980 DOI: 10.1038/s41598-019-44933-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/11/2018] [Accepted: 01/30/2019] [Indexed: 01/11/2023] Open
Abstract
We investigated the effectiveness of soluble Receptor for Advanced Glycation Endproducts (sRAGE) in attenuating angiotensin II (AngII)-induced left ventricular hypertrophy (LVH) using in vivo 9.4T cine-magnetic resonance imaging (CINE-MRI). Mice were divided into four groups: AngII (n = 9), saline (n = 10), sRAGE (n = 10), and AngII + sRAGE (n = 10). CINE-MRI was performed in each group after administration of the AngII or sRAGE, and CINE-MR images were analyzed to obtain parameters indicating cardiac anatomical and functional changes including end-diastolic and end-systolic blood volume, end-diastolic and end-systolic myocardial volume, ejection fraction, end-diastolic and end-systolic myocardial mass, and LV wall thickness. LVH observed in AngII group was significantly attenuated by sRAGE. These trends were also observed in histological analysis, demonstrating that cardiac function tracking using in vivo and real-time 9.4T MR imaging provides valuable information about the cardiac remodeling induced by AngII and sRAGE in an AngII-induced LV hypertrophy mice model.
Collapse
|
27
|
Liu L, Viel A, Le Saux G, Plawinski L, Muggiolu G, Barberet P, Pereira M, Ayela C, Seznec H, Durrieu MC, Olive JM, Audoin B. Remote imaging of single cell 3D morphology with ultrafast coherent phonons and their resonance harmonics. Sci Rep 2019; 9:6409. [PMID: 31015541 PMCID: PMC6478725 DOI: 10.1038/s41598-019-42718-5] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/21/2019] [Accepted: 04/03/2019] [Indexed: 11/21/2022] Open
Abstract
Cell morphological analysis has long been used in cell biology and physiology for abnormality identification, early cancer detection, and dynamic change analysis under specific environmental stresses. This work reports on the remote mapping of cell 3D morphology with an in-plane resolution limited by optics and an out-of-plane accuracy down to a tenth of the optical wavelength. For this, GHz coherent acoustic phonons and their resonance harmonics were tracked by means of an ultrafast opto-acoustic technique. After illustrating the measurement accuracy with cell-mimetic polymer films we map the 3D morphology of an entire osteosarcoma cell. The resulting image complies with the image obtained by standard atomic force microscopy, and both reveal very close roughness mean values. In addition, while scanning macrophages and monocytes, we demonstrate an enhanced contrast of thickness mapping by taking advantage of the detection of high-frequency resonance harmonics. Illustrations are given with the remote quantitative imaging of the nucleus thickness gradient of migrating monocyte cells.
Collapse
Affiliation(s)
- Liwang Liu
- University of Bordeaux, CNRS UMR 5295, I2M, F-33400, Talence, France
| | - Alexis Viel
- University of Bordeaux, CNRS UMR 5295, I2M, F-33400, Talence, France
| | - Guillaume Le Saux
- University of Bordeaux, CNRS UMR 5248, Bordeaux INP, CBMN, F-33600, Pessac, France
| | - Laurent Plawinski
- University of Bordeaux, CNRS UMR 5248, Bordeaux INP, CBMN, F-33600, Pessac, France
| | - Giovanna Muggiolu
- University of Bordeaux, CNRS UMR 5797, CENBG, F-33170, Gradignan, France
| | - Philippe Barberet
- University of Bordeaux, CNRS UMR 5797, CENBG, F-33170, Gradignan, France
| | - Marco Pereira
- University of Bordeaux, CNRS UMR 5218, IMS, F-33400, Talence, France
| | - Cédric Ayela
- University of Bordeaux, CNRS UMR 5218, IMS, F-33400, Talence, France
| | - Hervé Seznec
- University of Bordeaux, CNRS UMR 5797, CENBG, F-33170, Gradignan, France
| | | | - Jean-Marc Olive
- University of Bordeaux, CNRS UMR 5295, I2M, F-33400, Talence, France
| | - Bertrand Audoin
- University of Bordeaux, CNRS UMR 5295, I2M, F-33400, Talence, France.
| |
Collapse
|
28
|
Upputuri PK, Pramanik M. Photoacoustic imaging in the second near-infrared window: a review. JOURNAL OF BIOMEDICAL OPTICS 2019; 24:1-20. [PMID: 30968648 PMCID: PMC6990072 DOI: 10.1117/1.jbo.24.4.040901] [Citation(s) in RCA: 96] [Impact Index Per Article: 19.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/02/2018] [Accepted: 03/18/2019] [Indexed: 05/04/2023]
Abstract
Photoacoustic (PA) imaging is an emerging medical imaging modality that combines optical excitation and ultrasound detection. Because ultrasound scatters much less than light in biological tissues, PA generates high-resolution images at centimeters depth. In recent years, wavelengths in the second near-infrared (NIR-II) window (1000 to 1700 nm) have been increasingly explored due to its potential for preclinical and clinical applications. In contrast to the conventional PA imaging in the visible (400 to 700 nm) and the first NIR-I (700 to 1000 nm) window, PA imaging in the NIR-II window offers numerous advantages, including high spatial resolution, deeper penetration depth, reduced optical absorption, and tissue scattering. Moreover, the second window allows a fivefold higher light excitation energy density compared to the visible window for enhancing the imaging depth significantly. We highlight the importance of the second window for PA imaging and discuss the various NIR-II PA imaging systems and contrast agents with strong absorption in the NIR-II spectral region. Numerous applications of NIR-II PA imaging, including whole-body animal imaging and human imaging, are also discussed.
Collapse
Affiliation(s)
- Paul Kumar Upputuri
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| | - Manojit Pramanik
- Nanyang Technological University, School of Chemical and Biomedical Engineering, Singapore
| |
Collapse
|
29
|
Moore MJ, El-Rass S, Xiao Y, Wang Y, Wen XY, Kolios MC. Simultaneous ultra-high frequency photoacoustic microscopy and photoacoustic radiometry of zebrafish larvae in vivo. PHOTOACOUSTICS 2018; 12:14-21. [PMID: 30225194 PMCID: PMC6139000 DOI: 10.1016/j.pacs.2018.08.004] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/14/2018] [Revised: 08/16/2018] [Accepted: 08/23/2018] [Indexed: 05/07/2023]
Abstract
With their optically transparent appearance, zebrafish larvae are readily imaged with optical-resolution photoacoustic (PA) microscopy (OR-PAM). Previous OR-PAM studies have mapped endogenous chromophores (e.g. melanin and hemoglobin) within larvae; however, anatomical features cannot be imaged with OR-PAM alone due to insufficient optical absorption. We have previously reported on the photoacoustic radiometry (PAR) technique, which can be used simultaneously with OR-PAM to generate images dependent upon the optical attenuation properties of a sample. Here we demonstrate application of the duplex PAR/PA technique for label-free imaging of the anatomy and vasculature of zebrafish larvae in vivo at 200 and 400 MHz ultrasound detection frequencies. We then use the technique to assess the effects of anti-angiogenic drugs on the development of the larval vasculature. Our results demonstrate the effectiveness of simultaneous PAR/PA for acquiring anatomical images of optically transparent samples in vivo, and its potential applications in assessing drug efficacy and embryonic development.
Collapse
Affiliation(s)
- Michael J. Moore
- Department of Physics, Ryerson University, Toronto, M5B 2K3, Canada
- Institute for Biomedical Engineering and Science Technology, A Partnership Between Ryerson University and St. Michael’s Hospital, Toronto, M5B 1W8, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael’s Hospital, Toronto, M5B 1W8, Canada
| | - Suzan El-Rass
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael’s Hospital, Toronto, M5B 1W8, Canada
- Zebrafish Centre for Advanced Drug Discovery, Li Ka Shing Knowledge Institute, St Michael’s Hospital, Toronto, M5B 1W8, Canada
- Institute of Medical Science, Departments of Medicine, Laboratory Medicine and Pathobiology & Physiology, University of Toronto, Toronto, M5S 1A1, Canada
| | - Yongliang Xiao
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael’s Hospital, Toronto, M5B 1W8, Canada
- Zebrafish Centre for Advanced Drug Discovery, Li Ka Shing Knowledge Institute, St Michael’s Hospital, Toronto, M5B 1W8, Canada
- Institute of Medical Science, Departments of Medicine, Laboratory Medicine and Pathobiology & Physiology, University of Toronto, Toronto, M5S 1A1, Canada
| | - Youdong Wang
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael’s Hospital, Toronto, M5B 1W8, Canada
- Zebrafish Centre for Advanced Drug Discovery, Li Ka Shing Knowledge Institute, St Michael’s Hospital, Toronto, M5B 1W8, Canada
- Institute of Medical Science, Departments of Medicine, Laboratory Medicine and Pathobiology & Physiology, University of Toronto, Toronto, M5S 1A1, Canada
| | - Xiao-Yan Wen
- Institute for Biomedical Engineering and Science Technology, A Partnership Between Ryerson University and St. Michael’s Hospital, Toronto, M5B 1W8, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael’s Hospital, Toronto, M5B 1W8, Canada
- Zebrafish Centre for Advanced Drug Discovery, Li Ka Shing Knowledge Institute, St Michael’s Hospital, Toronto, M5B 1W8, Canada
- Institute of Medical Science, Departments of Medicine, Laboratory Medicine and Pathobiology & Physiology, University of Toronto, Toronto, M5S 1A1, Canada
| | - Michael C. Kolios
- Department of Physics, Ryerson University, Toronto, M5B 2K3, Canada
- Institute for Biomedical Engineering and Science Technology, A Partnership Between Ryerson University and St. Michael’s Hospital, Toronto, M5B 1W8, Canada
- Keenan Research Center for Biomedical Science, Li Ka Shing Knowledge Institute, St Michael’s Hospital, Toronto, M5B 1W8, Canada
- Corresponding author at: Department of Physics, Ryerson University, Toronto, M5B 2K3, Canada.
| |
Collapse
|
30
|
Langer G, Berer T. Fluorescence quantum yield and excited state lifetime determination by phase sensitive photoacoustics: concept and theory. OPTICS LETTERS 2018; 43:5074-5077. [PMID: 30320822 DOI: 10.1364/ol.43.005074] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2018] [Accepted: 09/05/2018] [Indexed: 06/08/2023]
Abstract
In this Letter, we theoretically describe photoacoustic signal generation of molecules, for which triplet relaxation can be neglected, by considering the excited state lifetime, the fluorescence quantum yield, and the fast vibrational relaxation. We show that the phase response of the photoacoustic signal can be exploited to determine the excited state lifetime of dark molecules. For fluorescent molecules, the phase response can be used to determine the fluorescence quantum yield directly without the need of reference samples.
Collapse
|
31
|
Tang Y, Liu W, Li Y, Zhou Q, Yao J. Concurrent photoacoustic and ultrasound microscopy with a coaxial dual-element ultrasonic transducer. Vis Comput Ind Biomed Art 2018; 1:3. [PMID: 32240396 PMCID: PMC7098394 DOI: 10.1186/s42492-018-0003-4] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/01/2018] [Accepted: 06/25/2018] [Indexed: 11/20/2022] Open
Abstract
Simultaneous photoacoustic and ultrasound (PAUS) imaging has attracted increasing attention in biomedical research to probe the optical and mechanical properties of tissue. However, the resolution for majority of the existing PAUS systems is on the order of 1 mm as the majority are designed for clinical use with low-frequency US detection. Here we developed a concurrent PAUS microscopy that consists of optical-resolution photoacoustic microscopy (OR-PAM) and high-frequency US pulse-echo imaging. This dual-modality system utilizes a novel coaxial dual-element ultrasonic transducer (DE-UST) and provides anatomical and functional information with complementary contrast mechanisms, achieving a spatial resolution of 7 μm for PA imaging and 106 μm for US imaging. We performed phantom studies to validate the system’s performance. The vasculature of a mouse’s hind paw was imaged to demonstrate the potential of this hybrid system for biomedical applications.
Collapse
Affiliation(s)
- Yuqi Tang
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Wei Liu
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA
| | - Yang Li
- Department of Ophthalmology, Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, 90089, USA
| | - Qifa Zhou
- Department of Ophthalmology, Department of Biomedical Engineering, University of Southern California, Los Angeles, CA, 90089, USA
| | - Junjie Yao
- Department of Biomedical Engineering, Duke University, Durham, NC, 27708, USA.
| |
Collapse
|
32
|
Moore MJ, Strohm EM, Kolios MC. Triplex micron-resolution acoustic, photoacoustic, and optical transmission microscopy via photoacoustic radiometry. OPTICS EXPRESS 2018; 26:22315-22326. [PMID: 30130926 DOI: 10.1364/oe.26.022315] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/21/2018] [Accepted: 08/03/2018] [Indexed: 05/23/2023]
Abstract
We present a new sensing technique, termed photoacoustic radiometry (PAR), for mapping the optical attenuation properties of a sample. In PAR, laser pulses attenuated via transmission through the sample impinge on the ultrasound transducer and generate a photoacoustic (PA) signal within it. Spatial variation of the optical attenuation properties of the sample influences the amplitude of the PAR signal, providing image contrast. Performed simultaneously with pulse-echo ultrasound and PA imaging, this triplex imaging technique enables rapid characterization of samples with micrometer-resolution in a single scan. In this work, we demonstrate that the PAR technique can be easily integrated into existing PA microscopy systems, with applications in imaging biological samples and non-destructive evaluation of optically opaque materials such as silicon wafers.
Collapse
|
33
|
Wissmeyer G, Pleitez MA, Rosenthal A, Ntziachristos V. Looking at sound: optoacoustics with all-optical ultrasound detection. LIGHT, SCIENCE & APPLICATIONS 2018; 7:53. [PMID: 30839640 PMCID: PMC6107019 DOI: 10.1038/s41377-018-0036-7] [Citation(s) in RCA: 113] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2017] [Revised: 05/08/2018] [Accepted: 05/11/2018] [Indexed: 05/03/2023]
Abstract
Originally developed for diagnostic ultrasound imaging, piezoelectric transducers are the most widespread technology employed in optoacoustic (photoacoustic) signal detection. However, the detection requirements of optoacoustic sensing and imaging differ from those of conventional ultrasonography and lead to specifications not sufficiently addressed by piezoelectric detectors. Consequently, interest has shifted to utilizing entirely optical methods for measuring optoacoustic waves. All-optical sound detectors yield a higher signal-to-noise ratio per unit area than piezoelectric detectors and feature wide detection bandwidths that may be more appropriate for optoacoustic applications, enabling several biomedical or industrial applications. Additionally, optical sensing of sound is less sensitive to electromagnetic noise, making it appropriate for a greater spectrum of environments. In this review, we categorize different methods of optical ultrasound detection and discuss key technology trends geared towards the development of all-optical optoacoustic systems. We also review application areas that are enabled by all-optical sound detectors, including interventional imaging, non-contact measurements, magnetoacoustics, and non-destructive testing.
Collapse
Affiliation(s)
- Georg Wissmeyer
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging, Technische Universität München, Munich, Germany
| | - Miguel A. Pleitez
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging, Technische Universität München, Munich, Germany
| | - Amir Rosenthal
- Andrew and Erna Viterbi Faculty of Electrical Engineering, Technion - Israel Institute of Technology, Haifa, Israel
| | - Vasilis Ntziachristos
- Institute of Biological and Medical Imaging, Helmholtz Zentrum München, Neuherberg, Germany
- Chair of Biological Imaging, Technische Universität München, Munich, Germany
| |
Collapse
|
34
|
Liu W, Zhou Y, Wang M, Li L, Vienneau E, Chen R, Luo J, Xu C, Zhou Q, Wang LV, Yao J. Correcting the limited view in optical-resolution photoacoustic microscopy. JOURNAL OF BIOPHOTONICS 2018; 11. [PMID: 28971578 DOI: 10.1002/jbio.201700196] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/27/2017] [Revised: 09/14/2017] [Accepted: 09/27/2017] [Indexed: 05/15/2023]
Abstract
Optical-resolution photoacoustic microscopy (OR-PAM) has proven useful for anatomical and functional imaging with high spatial resolutions. However, the coherent signal generation and the desired reflection-mode detection in OR-PAM can result in a limited detectability of features aligned with the acoustic axis (ie, vertical structures). Here, we investigated the limited-view phenomenon in OR-PAM by simulating the generation and propagation of the acoustic pressure waves and determined the key optical parameters affecting the visibility of vertical structures. Proof-of-concept numerical experiments were performed with different illumination angles, optical foci and numerical apertures (NA) of the objective lens. The results collectively show that an NA of 0.3 can readily improve the visibility of vertical structures in a typical reflection-mode OR-PAM system. This conclusion was confirmed by numerical simulations on the cortical blood vessels in a mouse brain and by experiments in a suture-cross phantom and in a mouse brain in vivo.
Collapse
Affiliation(s)
- Wei Liu
- Department of Biomedical Engineering, Duke University, Durham, North Carolina
| | - Yuan Zhou
- Department of Biomedical Engineering, Duke University, Durham, North Carolina
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Mengran Wang
- School of Applied and Engineering Physics, Cornell University, Ithaca, New York
| | - Lei Li
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California
| | - Emelina Vienneau
- Department of Biomedical Engineering, Duke University, Durham, North Carolina
| | - Ruimin Chen
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California
| | - Jianwen Luo
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing, China
| | - Chris Xu
- School of Applied and Engineering Physics, Cornell University, Ithaca, New York
| | - Qifa Zhou
- Department of Biomedical Engineering, University of Southern California, Los Angeles, California
| | - Lihong V Wang
- Caltech Optical Imaging Laboratory, Andrew and Peggy Cherng Department of Medical Engineering, Department of Electrical Engineering, California Institute of Technology, Pasadena, California
| | - Junjie Yao
- Department of Biomedical Engineering, Duke University, Durham, North Carolina
| |
Collapse
|
35
|
Buma T, Conley NC, Choi SW. Multispectral photoacoustic microscopy of lipids using a pulsed supercontinuum laser. BIOMEDICAL OPTICS EXPRESS 2018; 9:276-288. [PMID: 29359103 PMCID: PMC5772582 DOI: 10.1364/boe.9.000276] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/25/2017] [Revised: 11/30/2017] [Accepted: 12/16/2017] [Indexed: 05/06/2023]
Abstract
We demonstrate optical resolution photoacoustic microscopy (OR-PAM) of lipid-rich tissue between 1050-1714 nm using a pulsed supercontinuum laser based on a large-mode-area photonic crystal fiber. OR-PAM experiments of lipid-rich samples show the expected optical absorption peaks near 1210 and 1720 nm. These results show that pulsed supercontinuum lasers are promising for OR-PAM applications such as label-free histology of lipid-rich tissue and imaging small animal models of disease.
Collapse
Affiliation(s)
- Takashi Buma
- Department of Electrical, Computer, and Biomedical Engineering, Union College, Schenectady, NY 12308, USA
| | - Nicole C. Conley
- Department of Electrical, Computer, and Biomedical Engineering, Union College, Schenectady, NY 12308, USA
| | - Sang Won Choi
- Department of Electrical, Computer, and Biomedical Engineering, Union College, Schenectady, NY 12308, USA
- Currently with the Department of Biomedical Engineering, University of Michigan, Ann Arbor, MI 48109, USA
| |
Collapse
|
36
|
Behzadi S, Serpooshan V, Tao W, Hamaly MA, Alkawareek MY, Dreaden EC, Brown D, Alkilany AM, Farokhzad OC, Mahmoudi M. Cellular uptake of nanoparticles: journey inside the cell. Chem Soc Rev 2017; 46:4218-4244. [PMID: 28585944 PMCID: PMC5593313 DOI: 10.1039/c6cs00636a] [Citation(s) in RCA: 1349] [Impact Index Per Article: 192.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/01/2023]
Abstract
Nanoscale materials are increasingly found in consumer goods, electronics, and pharmaceuticals. While these particles interact with the body in myriad ways, their beneficial and/or deleterious effects ultimately arise from interactions at the cellular and subcellular level. Nanoparticles (NPs) can modulate cell fate, induce or prevent mutations, initiate cell-cell communication, and modulate cell structure in a manner dictated largely by phenomena at the nano-bio interface. Recent advances in chemical synthesis have yielded new nanoscale materials with precisely defined biochemical features, and emerging analytical techniques have shed light on nuanced and context-dependent nano-bio interactions within cells. In this review, we provide an objective and comprehensive account of our current understanding of the cellular uptake of NPs and the underlying parameters controlling the nano-cellular interactions, along with the available analytical techniques to follow and track these processes.
Collapse
Affiliation(s)
- Shahed Behzadi
- Center for Nanomedicine and Department of Anesthesiology, Brigham and Women's Hospital, Harvard Medical School, Boston, MA 02115, USA.
| | | | | | | | | | | | | | | | | | | |
Collapse
|
37
|
Upputuri PK, Periyasamy V, Kalva SK, Pramanik M. A High-performance Compact Photoacoustic Tomography System for In Vivo Small-animal Brain Imaging. J Vis Exp 2017:55811. [PMID: 28671657 PMCID: PMC5608463 DOI: 10.3791/55811] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2023] Open
Abstract
In vivo small-animal imaging has an important role to play in preclinical studies. Photoacoustic tomography (PAT) is an emerging hybrid imaging modality that shows great potential for both preclinical and clinical applications. Conventional optical parametric oscillator-based PAT (OPO-PAT) systems are bulky and expensive and cannot provide high-speed imaging. Recently, pulsed-laser diodes (PLDs) have been successfully demonstrated as an alternative excitation source for PAT. Pulsed-laser diode PAT (PLD-PAT) has been successfully demonstrated for high-speed imaging on photoacoustic phantoms and biological tissues. This work provides a visualized experimental protocol for in vivo brain imaging using PLD-PAT. The protocol includes the compact PLD-PAT system configuration and its description, animal preparation for brain imaging, and a typical experimental procedure for 2D cross-sectional rat brain imaging. The PLD-PAT system is compact and cost-effective and can provide high-speed, high-quality imaging. Brain images collected in vivo at various scan speeds are presented.
Collapse
Affiliation(s)
- Paul Kumar Upputuri
- School of Chemical and Biomedical Engineering, Nanyang Technological University
| | - Vijitha Periyasamy
- School of Chemical and Biomedical Engineering, Nanyang Technological University
| | - Sandeep Kumar Kalva
- School of Chemical and Biomedical Engineering, Nanyang Technological University
| | - Manojit Pramanik
- School of Chemical and Biomedical Engineering, Nanyang Technological University;
| |
Collapse
|
38
|
Liang Y, Jin L, Guan BO, Wang L. 2 MHz multi-wavelength pulsed laser for functional photoacoustic microscopy. OPTICS LETTERS 2017; 42:1452-1455. [PMID: 28362790 DOI: 10.1364/ol.42.001452] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Fast functional photoacoustic microscopy requires multi-wavelength pulsed laser sources with high pulse repetition rates, short wavelength switching time, and sufficient pulse energies. Here, we report the development of a stimulated-Raman-scattering-based multi-wavelength pulsed laser source for fast functional photoacoustic imaging. The new laser source is pumped with a 532 nm 1 MHz pulsed laser. The 532 nm laser beam is split into two: one pumps a 5 m optical fiber to excite a 558 nm wavelength via stimulated Raman scattering; the other goes through a 50 m optical fiber to delay the 532 nm pulse by 220 ns. The two beams are combined and coupled into an optical fiber for photoacoustic excitation. As a result, the new laser source can generate 2 million pulses per second, switch wavelengths in 220 ns, and provide hundreds of nanojoules pulse energy for each wavelength. Using this laser source, we demonstrate optical-resolution photoacoustic imaging of microvascular structures and oxygen saturation in the mouse ear. The ultrashort wavelength switching time enables oxygen saturation imaging of flowing red blood cells, which is valuable for high-resolution functional imaging.
Collapse
|
39
|
Upputuri PK, Krisnan M, Pramanik M. Microsphere enabled subdiffraction-limited optical-resolution photoacoustic microscopy: a simulation study. JOURNAL OF BIOMEDICAL OPTICS 2017; 22:45001. [PMID: 27901548 DOI: 10.1117/1.jbo.22.4.045001] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/15/2016] [Accepted: 11/07/2016] [Indexed: 05/21/2023]
Abstract
Optical resolution photoacoustic microscopy (ORPAM) is a high-resolution hybrid imaging modality having potential for microscale in vivo imaging. Optical diffraction limits the lateral resolution of ORPAM. A photonic nanojet (PNJ) was used to break this diffraction limit. A single round microsphere can generate a PNJ with subwavelength waist, but its short axial length limits its applications to surface imaging only. We investigate different sphere designs to achieve ultralong nanojets that will make the nanojet more viable in far-field applications, such as photoacoustic imaging. The PNJ properties, including effective length, waist size, working distance, and peak intensity, can be tuned and controlled by changing the sphere design and its refractive index. A truncated multilayer microsphere design could generate an ultraelongated PNJ with length larger than ∼172λ (∼138 μm) while retaining a large working distance ∼32λ (∼26 μm). Through simulation study, we observed ∼11-fold enhancement in lateral resolution with 5 μm round sphere (refractive index 2.2) when used in a conventional ORPAM setup with NA=0.1 and λ=800 nm.
Collapse
Affiliation(s)
- Paul Kumar Upputuri
- Nanyang Technological University, School of Chemical and Biomedical Engineering, 62 Nanyang Drive, Singapore 637459, Singapore
| | - Moganasundari Krisnan
- Nanyang Technological University, School of Chemical and Biomedical Engineering, 62 Nanyang Drive, Singapore 637459, Singapore
| | - Manojit Pramanik
- Nanyang Technological University, School of Chemical and Biomedical Engineering, 62 Nanyang Drive, Singapore 637459, Singapore
| |
Collapse
|
40
|
Abudayyeh I, Tran BG, Tobis JM. Optimizing Coronary Angioplasty with FFR and Intravascular Imaging. CURRENT CARDIOVASCULAR RISK REPORTS 2017. [DOI: 10.1007/s12170-017-0534-9] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
41
|
Pérez-Cota F, Smith RJ, Moradi E, Marques L, Webb KF, Clark M. High resolution 3D imaging of living cells with sub-optical wavelength phonons. Sci Rep 2016; 6:39326. [PMID: 27996028 PMCID: PMC5171858 DOI: 10.1038/srep39326] [Citation(s) in RCA: 43] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/15/2016] [Accepted: 11/22/2016] [Indexed: 12/11/2022] Open
Abstract
Label-free imaging of living cells below the optical diffraction limit poses great challenges for optical microscopy. Biologically relevant structural information remains below the Rayleigh limit and beyond the reach of conventional microscopes. Super-resolution techniques are typically based on the non-linear and stochastic response of fluorescent labels which can be toxic and interfere with cell function. In this paper we present, for the first time, imaging of live cells using sub-optical wavelength phonons. The axial imaging resolution of our system is determined by the acoustic wavelength (λa = λprobe/2n) and not on the NA of the optics allowing sub-optical wavelength acoustic sectioning of samples using the time of flight. The transverse resolution is currently limited to the optical spot size. The contrast mechanism is significantly determined by the mechanical properties of the cells and requires no additional contrast agent, stain or label to image the cell structure. The ability to breach the optical diffraction limit to image living cells acoustically promises to bring a new suite of imaging technologies to bear in answering exigent questions in cell biology and biomedicine.
Collapse
Affiliation(s)
- Fernando Pérez-Cota
- Optics and photonics group, Faculty of Engineering, University of Nottingham,University Park, Nottingham, UK
| | - Richard J. Smith
- Optics and photonics group, Faculty of Engineering, University of Nottingham,University Park, Nottingham, UK
| | - Emilia Moradi
- Optics and photonics group, Faculty of Engineering, University of Nottingham,University Park, Nottingham, UK
| | - Leonel Marques
- Optics and photonics group, Faculty of Engineering, University of Nottingham,University Park, Nottingham, UK
| | - Kevin F. Webb
- Optics and photonics group, Faculty of Engineering, University of Nottingham,University Park, Nottingham, UK
| | - Matt Clark
- Optics and photonics group, Faculty of Engineering, University of Nottingham,University Park, Nottingham, UK
| |
Collapse
|
42
|
He H, Wissmeyer G, Ovsepian SV, Buehler A, Ntziachristos V. Hybrid optical and acoustic resolution optoacoustic endoscopy. OPTICS LETTERS 2016; 41:2708-10. [PMID: 27304269 DOI: 10.1364/ol.41.002708] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/07/2023]
Abstract
We propose the implementation of hybrid optical and acoustic resolution optoacoustic endoscopy. Laser light is transmitted to tissue by two types of illumination for achieving optical and acoustic resolution imaging. A 20 MHz ultrasound detector is used for recording optoacoustic signals. The endoscopy probe attains a 3.6 mm diameter and is fully encapsulated into a catheter system. We validate the imaging performance of the hybrid endoscope on phantoms and ex vivo, and discuss the necessity for the extended resolution and depth range of endoscopy achieved.
Collapse
|