1
|
Zhang K, Zhang S, Shi Y, Zhang L, Fu B. Effects of disinfectants on physical properties of denture base resins: A systematic review and meta-analysis. J Prosthet Dent 2024; 131:841-858. [PMID: 35465961 DOI: 10.1016/j.prosdent.2022.03.020] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2021] [Revised: 03/14/2022] [Accepted: 03/15/2022] [Indexed: 11/16/2022]
Abstract
STATEMENT OF PROBLEM The disinfection of removable dental prostheses and orthodontic appliances is essential to preventing transmission of pathogens. However, whether different disinfection solutions and durations affect the physical properties of denture base resins is unclear. PURPOSE The purpose of this systematic review and meta-analysis was to statistically analyze the influence of disinfectants on the physical properties of denture base resins. MATERIAL AND METHODS A systematic search in Medline, Embase, PubMed, and Cochrane Library databases was conducted to evaluate the effects of chemical disinfection on the physical properties of denture base resins such as surface morphology, roughness, hardness, and flexural strength. Of 1909 studies, 44 studies were included in the systematic review and 41 in the meta-analysis. Heterogeneity was analyzed by using I2 statistics. The influence of different disinfection solutions and durations on the physical properties was further analyzed, and the risk of bias evaluated. Statistical analyses were performed by using the RevMan 5.4 software program with the standardized mean differences (SMDs) and 95% confidence intervals (CIs). RESULTS Of the 44 included studies, 40 studies were assessed as having a low risk of bias, and 4 had an unclear risk of bias. Meta-analysis results showed that compared with the control, disinfection could not significantly affect surface roughness and hardness within 60 minutes of immersion in disinfectant solutions or flexural strength within 30 minutes (roughness: P=.79, I2=0%; flexural strength: P=.08, I2=0%; hardness: P=.05, I2=19%). In addition, the physical properties were not significantly affected when glutaraldehyde, chlorhexidine, and peracetic acid were repeatedly used for more than 30 minutes. CONCLUSIONS Most of the disinfectants did not reduce the physical properties of denture base resin within 30 minutes of immersion. Glutaraldehyde, chlorhexidine, and peracetic acid are recommended if longer immersion or repeated disinfection is required.
Collapse
Affiliation(s)
- Kai Zhang
- Postgraduate student, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Dental Biomaterials and Devices for Zhejiang Provincial Engineering Research Center, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, Zhejiang, PR China
| | - Sisi Zhang
- Postgraduate student, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Dental Biomaterials and Devices for Zhejiang Provincial Engineering Research Center, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, Zhejiang, PR China
| | - Ying Shi
- Resident, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Dental Biomaterials and Devices for Zhejiang Provincial Engineering Research Center, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, Zhejiang, PR China
| | - Ling Zhang
- Associate Professor, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Dental Biomaterials and Devices for Zhejiang Provincial Engineering Research Center, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, Zhejiang, PR China
| | - Baiping Fu
- Professor, Stomatology Hospital, School of Stomatology, Zhejiang University School of Medicine, Dental Biomaterials and Devices for Zhejiang Provincial Engineering Research Center, Zhejiang Provincial Clinical Research Center for Oral Diseases, Key Laboratory of Oral Biomedical Research of Zhejiang Province, Cancer Center of Zhejiang University, Hangzhou, Zhejiang, PR China.
| |
Collapse
|
2
|
Alkahtani F. Efficacy of chemical and Photoactivated disinfectants against Candida Albicans and assessment of hardness, roughness, and mass loss of acrylic denture base resin. Photodiagnosis Photodyn Ther 2022; 39:102911. [PMID: 35595187 DOI: 10.1016/j.pdpdt.2022.102911] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2022] [Revised: 05/11/2022] [Accepted: 05/13/2022] [Indexed: 11/29/2022]
Abstract
AIM The present study aimed to assess the antimicrobial efficacy of hematoporphyrin derivative, sodium hypochlorite (NaOCl), glutaraldehyde (GaH), and a chlorhexidine (CHX) on mass loss (ML), microhardness, and surface roughness (Ra) of acrylic denture base colonized with C. Albicans. MATERIAL AND METHODS A total of 40 heat cure acrylic resin dentures were fabricated and inoculated by the American Type Culture Collection (ATCC) of C. Albicans in an in-vitro situation. Specimens were divided into four groups (n=10) based on the method of disinfection. Hematoporphyrin derivatives, 1% NaOCl, 2% GaH, and 4% CHX.The pre and post candida (CFU/ml) counts were recorded before and after immersion. ML, microhardness, and Ra of acrylic denture were also assessed. Statistical analysis was executed for CFU/mL (log10) for exposed C. Albicans by two-way ANOVA and Tukey's multiple tests (p>0.05). For normality of the data, Dunnet's Simultaneous test was performed. RESULTS In terms of candida strain analysis, pretreatment to posttreatment comparisons revealed a reduction in mean Candida count in all groups (p<0.05). The highest ML value after post candida disinfection of acrylic denture was observed in 2% GaH (1.587 ± 0.25) treated specimens. The least microhardness value was found in group 1 when treated with hematoporphyrin (0.97 ± 0.22 VHN) which was significantly different from other groups (p<0.05). Group 1 surface treated with hematoporphyrin derivate (1.84 ± 0.22 μm) showed the highest Ra values (p<0.05). CONCLUSION Acrylic denture base resin colonized with C. Albicans when treated with a chemical disinfectant of 4% chlorhexidine displayed the highest antimicrobial efficacy with reduced mass loss, less surface roughness, and maximum denture hardness.
Collapse
Affiliation(s)
- Fahad Alkahtani
- Department of prosthodontics, College of Dentistry, Prince Sattam Bin Abdulaziz University, Alkharj 11942, Saudi Arabia.
| |
Collapse
|
3
|
Asnaashari M, Motamedi S, Asnaashari N, Azari-Marhabi S. Antimicrobial Activity of Cold Plasma Treatment on Acrylic Denture Bases: An In Vitro Evaluation. J Lasers Med Sci 2020; 10:S13-S17. [PMID: 32021667 DOI: 10.15171/jlms.2019.s3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
Introduction: Cross-contamination between dental office and prosthetic laboratories is of utmost importance. The dental prosthesis could harbor tones of microorganisms harmful to health staff. It has been estimated that more than 60% of the prostheses delivered to clinics from laboratories or vice versa are contaminated with pathogenic microorganisms. Several disinfection methods and chemicals have been proposed for sanitizing prostheses. Cold plasma, or nonthermal plasma, has been introduced as a new method in medical equipment disinfection. The current study aimed to compare the antimicrobial effect of cold plasma and the routinely used alcohol-based impression disinfectant ASEPTOPRINT® on disinfecting dentures. Methods: In this experimental study, 30 maxillary complete dentures were used as the microbial source. Dentures were randomly divided into 3 groups: (1) cold plasma treatment for 30 seconds, (2) cold plasma for 60 seconds, (3) ASEPTOPRINT® spray. Microbial culturing was taken before and after disinfection in each group on both Blood Agar plates and Soborou Dextrose Agar (SDA) plates. After 48 hours incubation at 37°C, the number of colonies was counted using a digital colony counter and differences between the groups were analyzed. Results: A significant reduction in microbial colonies was observed after using all disinfection methods. ASEPTOPRINT® spray showed more antimicrobial effects comparing to cold plasma. Conclusion: The antimicrobial effect of ASEPTOPRINT® spray solution is more than cold plasma application on both microbial and fungal microorganisms. The time of plasma application was not accompanied by any significant differences in the results.
Collapse
Affiliation(s)
- Mohammad Asnaashari
- Laser Application in Medical Science Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Salar Motamedi
- Dental Research Center, Research Institute of Dental Sciences, School of Dentistry, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Negin Asnaashari
- Laser Application in Medical Science Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| | - Saranaz Azari-Marhabi
- Laser Application in Medical Science Research Center, Shahid Beheshti University of Medical Sciences, Tehran, Iran
| |
Collapse
|
4
|
Hombesh MN, Praveen B, Sinha HV, Prasanna BG, Sachin B, Chandrashekar S. Two years survivability of VITA 3D master shade matching guides after disinfection with isopropyl alcohol: An in vitro study. J Conserv Dent 2019; 22:275-280. [PMID: 31367113 PMCID: PMC6632636 DOI: 10.4103/jcd.jcd_573_18] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
Background Dental shade guides are used before restorative and prosthodontic procedures for the evaluation of tooth color. The spectral coverage of the specific shaded guide and a clinician's experience in shade matching are the two most important factors for a clinically viable shade match of the restoration to the given tooth. Repeated disinfection of the shade guide with disinfectant lead to a clinically significant difference of the shade to be matched, finally resulting in a clinically unacceptable prosthesis. The purpose of this study is to evaluate the effects of disinfection on various shade tabs of VITA 3D Master Shade guide after being subjected to 2 years of simulated disinfection with 70% isopropyl alcohol. Methodology Two sets of VITA 3-D Master Shade Guides were used. One set of each shade guide was assessed after simulated use and surface disinfection with 70% isopropyl alcohol (test group), while the other full set was subjected to cleansing with distilled water (control group). Spectrophotometer was used to measure each of the shade tabs. Readings were recorded at regular intervals of 120, 240, 360, 480, 600, 720, 840, and 960 disinfection cycles. The ΔE values obtained were used to examine the color difference. Results There was a significant difference in terms of ΔE between the shade tabs of control and test groups of VITA 3D Master shade guides after 960 cycles of disinfection. The change in mean ΔE was more in the test specimens in the shade tabs of VITA 3D Master Shade Guide tabs than the control specimens. These results are of statistical significance, but they might not be of any clinical significance. Conclusion There was a statistically significant but clinically nonsignificant color change in the shade tabs of VITA 3D Master shade guides after 2 years of simulated use and disinfection with 70% isopropyl alcohol.
Collapse
Affiliation(s)
- M N Hombesh
- Department of Prosthodontics, College of Dental Sciences, Davanagere, Karnataka, India
| | - B Praveen
- Department of Prosthodontics and Crown and Bridge, College of Dental Sciences, Davanagere, Karnataka, India
| | - Harsh Vardhan Sinha
- Department of Prosthodontics and Crown and Bridge, College of Dental Sciences, Davanagere, Karnataka, India
| | - B G Prasanna
- Department of Prosthodontics and Crown and Bridge, College of Dental Sciences, Davanagere, Karnataka, India
| | - Bhuvana Sachin
- Department of Prosthodontics and Crown and Bridge, College of Dental Sciences, Davanagere, Karnataka, India
| | - Shashidhar Chandrashekar
- Department of Conservative Dentistry and Endodontics, SMBT Dental College and Hospital, Sangamner, Maharashtra, India
| |
Collapse
|
5
|
Amin M, Ardaneh M, Hashemzadeh M, Asarehzadegan Dezfuli A, JafarZadeh E. In vitro antibacterial effect of deconex and sodium hypochlorite against bacterial taxa isolated from dental units. Infect Drug Resist 2019; 12:805-814. [PMID: 31114262 PMCID: PMC6489653 DOI: 10.2147/idr.s197988] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Accepted: 02/18/2019] [Indexed: 11/23/2022] Open
Abstract
Purpose: Dental unit's environment and relevant instruments are a major source of infectious diseases caused by a variety of microorganisms. The application of various disinfectants is one of the most effective methods for reducing or eliminating microbial contamination. The objective of this study was to evaluate the antibacterial effects of deconex and sodium hypochlorite against bacterial taxa isolated from dental unit's environment of Ahvaz Jundishapur University of Medical Sciences, southwest of Iran. Methods: In order to evaluate the quality of disinfection, sampling was performed from different parts of 100 clinical units. For bacterial recovery and isolation, samples were enriched and cultured onto different microbiological culture media. Species identification was carried out using phenotypic and molecular methods (16S rDNA sequence analysis). In vitro activity of sodium hypochlorite and deconex were determined by the broth micro-dilution method. Results: According to conventional techniques, Bacillus spp (48%) was the most frequently encountered isolates, followed by staphylococcus spp (26%). By using both techniques, Bacillus subtilis was the most frequently encountered species (n=23, 21%), followed by Bacillus licheniformis (n=8, 7.4%), Streptococcus pneumonia (n=8, 7.4%), Staphylococcus epidermidis (n=8, 7.4%), Staphylococcus saprophyticus (n=8, 7.4%) and Staphylococcus warneri. The highest levels of contamination were observed in oral medications. The deconex had lower minimum inhibitory concentration (MIC) concentration in comparasion to sodium hypochlorite, which showed that deconex was a much more potent disinfectant. Conclusion: In conclusion, the results of the present in vitro study showed that deconex had promising results for decontamination of the tested microorganism, and it is recommended for disinfecting of dental units and environment. In this study, the high percentage of dental unit's contamination showed the need to improve disinfection procedures, sterilization systems, and the use of an appropriate concentration of deconex and sodium hypochlorite for dental units decontamination .
Collapse
Affiliation(s)
- Mansour Amin
- Department of Microbiology, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
- Infectious and Tropical Diseases Research Center, Health Research Institute, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Marieh Ardaneh
- Department of Microbiology, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Mohammad Hashemzadeh
- Department of Microbiology, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
- Infectious and Tropical Diseases Research Center, Health Research Institute, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Aram Asarehzadegan Dezfuli
- Department of Microbiology, School of Medicine, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| | - Elham JafarZadeh
- Laboratory of Taleqhani Hospital, Ahvaz Jundishapur University of Medical Sciences, Ahvaz, Iran
| |
Collapse
|
6
|
Arruda CNF, Salles MM, Badaró MM, Sorgini DB, Oliveira VC, Macedo AP, Silva-Lovato CH, Paranhos HFO. Evaluation of biofilm removal and adverse effects on acrylic resin by diluted concentrations of sodium hypochlorite and Ricinus communis solutions. Gerodontology 2018; 35:246-253. [PMID: 29790590 DOI: 10.1111/ger.12348] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 04/09/2018] [Indexed: 12/14/2022]
Abstract
PURPOSE To verify whether 0.1% and 0.2% sodium hypochlorite (NaOCl), and 8% Ricinus communis (RC) were able to remove denture biofilm without causing deleterious effects to acrylic resin. BACKGROUND Previous data show that denture cleansers are effective in reducing biofilm; however, they can change acrylic resin properties. METHODS In a crossover trial, 47 denture wearers brushed and soaked their dentures (20 min/14 d): control, 0.85% saline; SH1, 0.1% NaOCl; SH2, 0.2% NaOCl and RC. Denture biofilm on the intaglio surface was stained, photographed and quantified (Image Tool® ). Furthermore, 80 rectangular and 80 disc-shaped specimens (Lucitone 550) were assigned into tested solutions (n = 20), simulating 5 years of daily short immersions (20 minutes). A colorimeter and the National Bureau of Standards units (NBS) determined colour data (ΔE). Surface roughness and flexural strength were measured using rugosimeter and universal testing machine, respectively. Data were compared by the Friedman test (α = .05) followed by Wilcoxon, corrected by Bonferroni (α = .005) (clinical) and Kruskal-Wallis followed by the Dunn test (α = .05) (laboratorial). RESULTS SH2 (MR=1.77) showed lower biofilm coverage; SH1 (MR = 2.37) and RC (MR = 2.74) presented intermediated values. RC (1.10 [0.96:1.75]) revealed higher colour alteration than SH1 (0.71 [0.62:0.80]) and SH2 (0.74 [0.58:0.85]); however, NBS classified all solutions as "trace" (0.0-0.5). There was no statistical significance for surface roughness (P = .760) and flexural strength (P = .547). CONCLUSIONS The 0.2% NaOCl showed the best clinical performance and did not cause adverse effects on acrylic resin on laboratory analyses.
Collapse
Affiliation(s)
- Carolina N F Arruda
- Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| | - Marcela M Salles
- Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| | - Maurício M Badaró
- Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| | - Danilo B Sorgini
- Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| | - Viviane C Oliveira
- Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| | - Ana P Macedo
- Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| | - Cláudia H Silva-Lovato
- Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| | - Helena F O Paranhos
- Department of Dental Materials and Prosthodontics, Dental School of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| |
Collapse
|
7
|
Badrian H, Davoudi A, Molazem M, Zare MH. The effect of spraying different disinfectants on condensational silicone impressions; an in vitro study. J Indian Prosthodont Soc 2016; 15:263-7. [PMID: 26929523 PMCID: PMC4762328 DOI: 10.4103/0972-4052.161091] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
Abstract
Background: Dentistry equipment are exposed to different types of pathogenic microorganisms. The aim of this study was to investigate the effect of spraying three different types of disinfectants on condensational silicones after 5 and 10 min. Materials and Methods: Totally, 66 circular samples of condensational silicone impression materials of 1 cm diameter and 2 mm thickness were contaminated by Staphylococcus aureus, Pseudomonas aeruginosa, and Candida albicans fungus. Except for control samples, all of them were disinfected with sodium hypochlorite (NaOCl) 0.525%, Deconex and Epimax by spraying method. Afterward, they kept in plastic bags with humid rolled cotton for 5 and 10 min. In order to isolate microbiotas, the samples were immersed in 2% trypsin for 1 h and diluted with normal saline in a portion of 1, 1/2, and 1/4. The trypsin suspensions were transferred to culture plates for incubation and colony-forming unit assay. The data were analyzed by Mann–Whitney test and SPSS software version 16 at a significant level of 0.05. Results: There was a meaningful difference between disinfection effects of Epimax-Deconex for all mentioned microorganisms after 5 min (P = 0.034), and between disinfection effects of NaOCl 0.525%-Epimax for S. aureus (P = 0.043) and P. aeruginosa (P = 0.046) after 5 min. Furthermore, there was a meaningful difference between disinfection effects of Epimax-Deconex (P = 0.034) and NaOCl 0.525%-Epimax (P = 0.034) for P. aeruginosa after 10 min. Conclusion: Condensational silicone can be effectively disinfected by spraying tested three disinfecting agents. More specifically, Deconex showed the best results compared to the other agents.
Collapse
Affiliation(s)
- Hamid Badrian
- Department of Operative, Dental School, Shahid Sadoughi University of Medical Sciences, Yazd, Iran
| | - Amin Davoudi
- Dental Students Research Center, Isfahan University of Medical Sciences, Isfahan, Iran
| | - Meysam Molazem
- Department of Prosthodontics, School of Dentistry, Shahid Sadoughi University Medical Sciences, Yazd, Iran
| | - Mohammad Hossein Zare
- Department of Prosthodontics, School of Dentistry, Shahid Sadoughi University Medical Sciences, Yazd, Iran
| |
Collapse
|
8
|
Serra G, de Morais LS, Elias CN. Surface morphology changes of acrylic resins during finishing and polishing phases. Dental Press J Orthod 2015; 18:26-30. [PMID: 24351146 DOI: 10.1590/s2176-94512013000600005] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
INTRODUCTION The finishing and polishing phases are essential to improve smoothness and shining on the surface of acrylic resins used to make removable orthodontic appliances. A good surface finishing reduces roughness, which facilitates hygiene, prevents staining and provides greater comfort to the patients. OBJECTIVE The aim of this paper was to analyze the changes on surface morphology of acrylic resins during finishing and polishing phases. METHODS Thirty discs (10 mm in diameter and 5 mm in length) were made with acrylic resin and randomly divided into ten groups. The control group did not receive any treatment while the other groups received gradual finishing and polishing. The last group received the entire finishing and polishing procedures. Surface morphology was qualitatively analyzed through scanning electron microscopy and quantitatively analyzed through a laser profilometer test. RESULTS The acrylic resin surfaces without treatment showed bubbles which were not observed in the subsequent phases. Wearing out with multilaminated burs, finishing with wood sandpaper and finishing with water sandpaper resulted in surfaces with decreasing irregularities. The surfaces that were polished with pumice and with low abrasive liquids showed high superficial smoothness. CONCLUSIONS Highly smooth acrylic resin surfaces can be obtained after mechanical finishing and polishing performed with multilaminated burs, wood sandpaper, water sandpaper, pumice and low abrasive liquids.
Collapse
|
9
|
Nakahara T, Harada A, Yamada Y, Odashima Y, Nakamura K, Inagaki R, Kanno T, Sasaki K, Niwano Y. Influence of a new denture cleaning technique based on photolysis of H(2)O(2) the mechanical properties and color change of acrylic denture base resin. Dent Mater J 2015; 32:529-36. [PMID: 23903632 DOI: 10.4012/dmj.2013-047] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
The purpose of this study was to evaluate the influence of a disinfection technique based on photolysis of H2O2 on the mechanical properties and color change of acrylic denture base resin. Resin specimens were immersed in 1 M H2O2 irradiated with light-emitting diode (LED) light at 400 nm for 1 week. The immersion duration of 1 week (168 h) corresponded to performing approximately 500 times of 20-min cleaning. Hydroxyl radicals are potent oxidants and they were generated via the photolysis of H2O2. Oxidative damage caused by these radicals included reduced flexural strength and altered color for the acrylic resin. Nonetheless, the degraded flexural strength and altered color of acrylic resin after 500 times of cleaning in the disinfection system would be within clinically acceptable levels.
Collapse
Affiliation(s)
- Tatsuro Nakahara
- Division of Fixed Prosthodontics, Tohoku University Graduate School of Dentistry, 4-1 Seiryo-machi, Aoba-ku, Sendai 980-8575, Japan
| | | | | | | | | | | | | | | | | |
Collapse
|
10
|
Sczepanski F, Sczepanski CRB, Berger SB, Consani RLX, Gonini-Júnior A, Guiraldo RD. Effect of sodium hypochlorite and peracetic acid on the surface roughness of acrylic resin polymerized by heated water for short and long cycles. Eur J Dent 2014; 8:533-537. [PMID: 25512737 PMCID: PMC4253112 DOI: 10.4103/1305-7456.143638] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022] Open
Abstract
OBJECTIVE To evaluate the surface roughness of acrylic resin submitted to chemical disinfection via 1% sodium hypochlorite (NaClO) or 1% peracetic acid (C2H4O3). MATERIALS AND METHODS The disc-shaped resin specimens (30 mm diameter ×4 mm height) were polymerized by heated water using two cycles (short cycle: 1 h at 74°C and 30 min at 100°C; conventional long cycle: 9 h at 74°C). The release of substances by these specimens in water solution was also quantified. Specimens were fabricated, divided into four groups (n = 10) depending on the polymerization time and disinfectant. After polishing, the specimens were stored in distilled deionized water. Specimens were immersed in 1% NaClO or 1% C2H4O3 for 30 min, and then were immersed in distilled deionized water for 20 min. The release of C2H4O3 and NaClO was measured via visual colorimetric analysis. Roughness was measured before and after disinfection. Roughness data were subjected to two-way ANOVA and Tukey's test. RESULTS There was no interaction between polymerization time and disinfectant in influencing the average surface roughness (Ra, P = 0.957). Considering these factors independently, there were significant differences between short and conventional long cycles (P = 0.012), but no significant difference between the disinfectants hypochlorite and C2H4O3 (P = 0.366). Visual colorimetric analysis did not detect release of substances. CONCLUSION It was concluded that there was the difference in surface roughness between short and conventional long cycles, and disinfection at acrylic resins polymerized by heated water using a short cycle modified the properties of roughness.
Collapse
Affiliation(s)
- Felipe Sczepanski
- Department of Restorative Dentistry, School of Dentistry, University North of Parana (UNOPAR), Londrina, PR, Brazil
| | | | - Sandrine Bittencourt Berger
- Department of Restorative Dentistry, School of Dentistry, University North of Parana (UNOPAR), Londrina, PR, Brazil
| | - Rafael Leonardo Xediek Consani
- Department of Prosthodontics and Periodontics, Piracicaba Dental School, State University of Campinas (UNICAMP), Piracicaba, SP, Brazil
| | - Alcides Gonini-Júnior
- Department of Restorative Dentistry, School of Dentistry, University North of Parana (UNOPAR), Londrina, PR, Brazil
| | - Ricardo Danil Guiraldo
- Department of Restorative Dentistry, School of Dentistry, University North of Parana (UNOPAR), Londrina, PR, Brazil
| |
Collapse
|
11
|
Retraction Statement. J Prosthodont 2013. [DOI: 10.1111/jopr.12000] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022] Open
|
12
|
Badrian H, Ghasemi E, Khalighinejad N, Hosseini N. The effect of three different disinfection materials on alginate impression by spray method. ISRN DENTISTRY 2012; 2012:695151. [PMID: 22900196 PMCID: PMC3410321 DOI: 10.5402/2012/695151] [Citation(s) in RCA: 18] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Subscribe] [Scholar Register] [Received: 04/11/2012] [Accepted: 06/06/2012] [Indexed: 11/23/2022]
Abstract
Introduction. The aim of this study was to investigate the effect of three different types of disinfectant agents on alginate impression material after 5 and 10 minutes. Method and Materials. In this in vitro experimental study, 66 circular samples of alginate impression material were contaminated with Staphylococcus aureus, Pseudomonas aeruginosa, and Candida albicans fungus. Except for control samples, all of them were disinfected with sodium hypochlorite 0.525, Deconex, and Epimax by way of spraying. Afterwards, they were kept in plastic bags with humid rolled cotton for 5 and 10 minutes. The number of colonies was counted after 24 and 48 hours for bacteria and after 72 hours for fungus. Statistical Mann-Whitney test was used for data analysis (α = 0.05). Results. After 5 minutes, Epimax showed the highest disinfection action on Staphylococcus aureus as it completely eradicated the bacteria. The disinfection capacity of different agents can be increased as time elapses except for Pseudomonas aeruginosa which was eradicated completely in both 5 and 10 minutes. Conclusion. This study revealed that alginate can be effectively disinfected by three types of disinfecting agents by spraying method, although Epimax showed the highest disinfection action after 10 minutes compared to other agents.
Collapse
Affiliation(s)
- Hamid Badrian
- Dental Implant Research Center, School of Dentistry, Isfahan University of Medical sciences, 81746-73461 Isfahan, Iran
| | | | | | | |
Collapse
|
13
|
Sharan S, Kavitha HR, Konde H, Kalahasti D. Effect of chemical disinfectant on the transverse strength of heat-polymerized acrylic resins subjected to mechanical and chemical polishing: an in vitro study. J Contemp Dent Pract 2012; 13:389-93. [PMID: 22918015 DOI: 10.5005/jp-journals-10024-1156] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
Abstract
AIMS To evaluate the effect of chemical disinfectant on the transverse strength of heat-polymerized acrylic resins subjected to mechanical and chemical polishing. MATERIALS AND METHODS A total of 256 rectangular specimens (65 * 10 * 3 mm) 128 per resin (Lucitone-199 and Acralyn-H) were fabricated. One side of each specimen was not polished and the other was either mechanically (n = 96) or chemically (n = 96) polished and immersed for 10, 30 and 60 minutes in 2% alkaline glutaraldehyde. Mechanically polished (n = 32) and chemically polished (n = 32) control specimens were immersed only in distilled water. The transverse strength (N/mm(2)) was tested for failure in a universal testing machine, at a crosshead speed of 5 mm/min. Data were statistically analyzed using 2-way ANOVA and Student t-test. RESULTS chemical polishing resulted in significantly lower transverse strength values than mechanical polishing. Lucitone- 199 resin demonstrated the highest overall transverse strength for the materials tested. Heat-polymerized acrylic resins either mechanically or chemically polished, did not demonstrate significant changes in transverse strength during immersion in the disinfecting solution tested, regardless of time of immersion. CONCLUSION Lucitone-199 resin demonstrated the highest overall transverse strength for the materials tested and significantly stronger than Acralyn-H with either type of polishing following immersion in 2% alkaline glutaraldehyde. CLINICAL SIGNIFICANCE There is a concern that immersion in chemical solutions often used for cleansing and disinfection of prostheses may undermine the strength and structure of denture base resins. In this study it was observed that, the transverse strength of samples of Lucitone-199 was higher than that of the samples of Acralyn-H. The chances of fracture of the denture made of Lucitone-199 are less than that of dentures made of Acralyn-H. The chemically polished dentures may be more prone to fracture than mechanically polished dentures.
Collapse
Affiliation(s)
- Smitha Sharan
- Department of Prosthodontics, NSVK Sri Venkateshwara Dental College and Hospital, Bengaluru-560083, Karnataka, India.
| | | | | | | |
Collapse
|
14
|
Fernandes FHCN, Orsi IA, Villabona CA. Effects of the peracetic acid and sodium hypochlorite on the colour stability and surface roughness of the denture base acrylic resins polymerised by microwave and water bath methods. Gerodontology 2012; 30:18-25. [DOI: 10.1111/j.1741-2358.2012.00640.x] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/30/2022]
|
15
|
Orsi IA, Andrade VG, Bonato PS, Raimundo LB, Herzog DS, Borie E. Glutaraldehyde release from heat-polymerized acrylic resins after disinfection and chemical and mechanical polishing. Braz Dent J 2011; 22:490-6. [DOI: 10.1590/s0103-64402011000600009] [Citation(s) in RCA: 9] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/14/2010] [Accepted: 03/27/2011] [Indexed: 11/22/2022] Open
Abstract
This study evaluated the release of glutaraldehyde from heat-polymerized acrylic resins subjected to disinfection followed by chemical and mechanical polishing. Ninety disc-shaped specimens (15 x 4 mm), 30 per resin (Lucitone 550, QC-20 and Classico), were made and assigned to 2 groups according to the type of polishing. One side of each specimen was not polished and the other was either mechanically (n=45) or chemically (n=45) polished, and immersed in water at 50°C for 1 h to allow the release of intrinsic substances and then kept in distilled water for 7 days. The specimens were disinfected by immersion in 2% glutaraldehyde for 10 min. After this period, 3 specimens from each group were immersed in water for 15, 30, 60, 120 and 240 min. For the 15-, 30-, 60-min immersions, 4 water exchanges were done at the end of period. High performance liquid chromatography (HPLC) was used to detect and quantify the glutaraldehyde released after each period. Data were analyzed statistically by two-way ANOVA and multiple comparisons were done by Tukey’s and Scheffé’s tests (α=0.05). No glutaraldehyde release was observed from the specimens with chemical polishing at any of the immersion periods, while the mechanically polished specimens released glutaraldehyde. In the groups with water exchanges, Lucitone released more disinfectant in the 15-min period (0.040 μg/mL), Classico in the 30-min (0.021 μg/mL) and 60-min (0.018 μg/mL) periods, and QC-20 the same amount (-1.760 μg/mL) in all periods. In the groups without water exchanges, Lucitone released the highest amount of disinfectant (-1.370 μg/mL), differing significantly from QC-20 (0022 g/mL) and Classico (0019 g/mL), which were similar. The findings of this showed that chemically polished specimens from the 3 resin brands did not release glutaraldehyde after different periods of immersion, while glutaraldehyde release was observed from the mechanically polished specimens, especially from those made of Lucitone resin.
Collapse
|
16
|
Jose A, Coco BJ, Milligan S, Young B, Lappin DF, Bagg J, Murray C, Ramage G. Reducing the Incidence of Denture Stomatitis: Are Denture Cleansers Sufficient? J Prosthodont 2010; 19:252-7. [DOI: 10.1111/j.1532-849x.2009.00561.x] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022] Open
|
17
|
Davi LR, Peracini A, de Queiroz Ribeiro N, Soares RB, da Silva CHL, de Freitas Oliveira Paranhos H, de Souza RF. Effect of the physical properties of acrylic resin of overnight immersion in sodium hypochlorite solution. Gerodontology 2009; 27:297-302. [DOI: 10.1111/j.1741-2358.2009.00336.x] [Citation(s) in RCA: 35] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
18
|
HASHIGUCHI M, NISHI Y, KANIE T, BAN S, NAGAOKA E. Bactericidal efficacy of glycine-type amphoteric surfactant as a denture cleaner and its influence on properties of denture base resins. Dent Mater J 2009; 28:307-14. [DOI: 10.4012/dmj.28.307] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
19
|
Paranhos HDFO, Davi LR, Peracini A, Soares RB, Lovato CHDS, Souza RFD. Comparison of physical and mechanical properties of microwave-polymerized acrylic resin after disinfection in sodium hypochlorite solutions. Braz Dent J 2009; 20:331-5. [DOI: 10.1590/s0103-64402009000400012] [Citation(s) in RCA: 28] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/16/2009] [Accepted: 09/16/2009] [Indexed: 11/21/2022] Open
Abstract
This study evaluated the color stability, surface roughness and flexural strength of a microwave-polymerized acrylic resin after immersion in sodium hypochlorite (NaOCl), simulating 20 min of disinfection daily during 180 days. Forty disk-shaped (15 x 4 mm) and 40 rectangular (65 x 10 x 3 mm) specimens were prepared with a microwave-polymerized acrylic resin (Onda-Cryl). Specimens were immersed in either 0.5% NaOCl, 1% NaOCl, Clorox/Calgon and distilled water (control). Color measurements were determined by a portable colorimeter. Three parallel lines, separated by 1.0 mm, were registered on each specimen before and after immersion procedures to analyze the surface roughness. The flexural strength was measured using a 3-point bending test in a universal testing machine with a 50 kgf load cell and a crosshead speed of 1 mm/min. Data were analyzed statistically by ANOVA and Tukey's test (?=0.05). There was no statistically significant differences (p>0.05) among the solutions for color, surface roughness and flexural strength. It may be concluded that immersion in NaOCl solutions simulating short-term daily use during 180 days did not influence the color stability, surface roughness and flexural strength of a microwave-polymerized acrylic resin.
Collapse
|
20
|
Ellakwa AE, El-Sheikh AM. Effect of chemical disinfectants and repair materials on the transverse strength of repaired heat-polymerized acrylic resin. J Prosthodont 2006; 15:300-5. [PMID: 16958731 DOI: 10.1111/j.1532-849x.2006.00131.x] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
Abstract
PURPOSE The purpose of this study was to evaluate both the effects of immersion in different chemical disinfectant solutions and the type of repair material on the transverse strength of repaired heat-polymerized acrylic resin. MATERIALS AND METHODS A total of 110 rectangular specimens (65 x 10 x 3 mm) of heat-polymerized acrylic resin (Triplex) were fabricated. After polymerization, the specimens were polished, then stored in distilled water at 37 degrees C for 1 week. The specimens were divided into 11 groups (n = 10) coded A to K. Specimens of Group A remained intact (control). The specimens of Groups C to F and Groups H to K were immersed in the following chemical disinfectant solutions (1%, 2.5%, and 5.25% sodium hypochlorite and 2% glutaraldehyde, respectively) for 10 minutes. The specimens of all groups except those of Group A were sectioned in the middle to create 10 mm gaps and repaired with the same resin (Groups B to F) and autopolymerizing acrylic resin (Groups G to K). The specimens of Groups C to F and Groups H to K were again immersed in the disinfectant solutions in the same sequence. The transverse strength (N/mm(2)) was tested for failure in a universal testing machine, at a crosshead speed of 5 mm/min. Two-way analysis of variance (ANOVA) was performed to evaluate the effects of both the disinfectant solutions and repair materials on the transverse strength of repaired specimens. All data were statistically analyzed using one-way analysis of variance followed by Tukey's test at 95% confidence level. RESULTS The repaired specimens treated with/without disinfectant solutions showed similar (p > 0.05) transverse strength values. No differences (p > 0.05) were detected among the repaired specimens either with heat-polymerized or autopolymerizing acrylic resins. The intact specimens showed transverse strength values (86.9 +/- 11.8) significantly higher (p < 0.05) than the values of the repaired specimens. CONCLUSIONS Among the repaired specimens, transverse strength was not affected after immersion in the disinfectants for the immersion period tested (10 min). The repair material, either heat-polymerized or autopolymerizing acrylic resin, had no effect on the transverse strength of the repaired acrylic resin specimens.
Collapse
Affiliation(s)
- Ayman E Ellakwa
- Department of Restorative Dentistry, Biomaterials Unit, College of Dentistry, King Faisal University, Dammam, Saudi Arabia
| | | |
Collapse
|
21
|
Sartori EA, Schmidt CB, Walber LF, Shinkai RSA. Effect of microwave disinfection on denture base adaptation and resin surface roughness. Braz Dent J 2006; 17:195-200. [PMID: 17262124 DOI: 10.1590/s0103-64402006000300004] [Citation(s) in RCA: 32] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/13/2005] [Accepted: 10/13/2005] [Indexed: 11/22/2022] Open
Abstract
This study evaluated the effect of disinfection methods [chemical disinfection (immersion in 100 ppm chloride solution) or microwave disinfection (690 W for 6 min)] on the internal adaptation of denture bases and resin surface roughness. For the adaptation test, 18 maxillary denture bases were obtained from stone casts duplicated from a metallic master model and submitted to the following treatments: 1) control (no disinfection), 2) chemical disinfection or 3) microwave disinfection. Disinfection procedures were performed twice (T1, T2) with a 7-day interval between them. Internal adaptation was measured at baseline (T0) and after T1 and T2 by weighing a vinyl polysiloxane film reproducing the gap between the resin base and the master model. For surface roughness measurement, 60 rectangular (5x10x40 mm) resin specimens were either mechanically or chemically polished and then submitted to the disinfection treatments. Surface roughness (Ra) was recorded after polishing (T0) and after T1 and T2. Data were analyzed by ANOVA GLM for repeated measures and Bonferroni correction at 5% significance level. Bases submitted to microwave disinfection had gradual increase of misfit, while bases immersed in chloride solution did not differ from the control group. Surface roughness increased in the mechanical polishing groups with microwave disinfection and decreased in the chemical polishing groups.
Collapse
Affiliation(s)
- Evandro Afonso Sartori
- Department of Prosthodontics, Dental School, Pontifical Catholic University of Rio Grande do Sul, Porto Alegre, RS, Brazil
| | | | | | | |
Collapse
|