1
|
Pitman J, Van Craenenbroeck M, Glibert M, Christiaens V. Screw loosening in angulation-correcting single implant restorations: A systematic review of in vitro studies. J Prosthet Dent 2024; 132:520-527. [PMID: 36116951 DOI: 10.1016/j.prosdent.2022.08.003] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 08/03/2022] [Accepted: 08/04/2022] [Indexed: 11/22/2022]
Abstract
STATEMENT OF PROBLEM Various options are available to allow angle correction for screw-retained restorations for malaligned implants, including angled abutments, angled screw channel abutments, and angled implants. However, the effect these angle correction components have on prosthetic screw loosening is unclear. PURPOSE The purpose of this systematic review was to assess the effect of angled abutments, angled screw channel abutments, and angled implants on prosthetic screw loosening. MATERIAL AND METHODS This manuscript followed the Preferred Reporting Items for the Systematic Review and Meta-Analyses (PRISMA) statement. Searches were performed through 31 December 2021 in PubMed/MEDLINE, EMBASE, and Web of Science with no year limit targeting in vitro studies evaluating the effect of angulation correction components on screw loosening. RESULTS A total of 460 articles were identified. After removing duplicates, 306 titles were screened. Nine of the remaining 36 articles selected for full-text analysis met the selection criteria. The qualitative analysis used data from 394 implants. All studies featured straight abutments as the control group, and, in 8 studies, the angle correction component was included on the level of the abutment. Only in 1 study was the angle correction component at the level of the implant. The angle correction of the prosthetic component varied from 0 degrees in all studies up to a maximum correction of 30 degrees. Statistically significant increases in screw loosening with increasing abutment angle correction were reported by multiple authors (P<.05). However, other articles reported nonsignificant differences in screw loosening because of angulation after cyclic loading (P>.05). The only study investigating angle correction at the implant level found significantly less screw loosening (P<.05) in the angled implant group compared with the nonangled implant group. CONCLUSIONS Several options are available to correct discrepancies between the surgical axis and the ideal prosthetic axis for rehabilitations supported by dental implants. The current evidence does not clearly indicate the superiority of any single solution for minimizing screw loosening.
Collapse
Affiliation(s)
- Jeremy Pitman
- PhD Candidate, Department of Periodontology and Oral Implantology, Dental School, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium.
| | - Maja Van Craenenbroeck
- Pre-doctoral student, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium
| | - Maarten Glibert
- Post-doctoral, Department of Periodontology and Oral Implantology, Dental School, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium
| | - Véronique Christiaens
- Professor, Department of Periodontology and Oral Implantology, Dental School, Faculty of Medicine and Health Sciences, Ghent University, Ghent, Belgium
| |
Collapse
|
2
|
Nogueira VDF, Rodrigues CDS, Grangeiro MTV, Contreras LPC, Marinho RMDM, Bottino MA. Interface adhesion on layered zirconia: Effects of the veneering ceramic material and veneering technique. J Prosthodont 2024; 33:677-683. [PMID: 37626443 DOI: 10.1111/jopr.13756] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2023] [Revised: 08/21/2023] [Accepted: 08/21/2023] [Indexed: 08/27/2023] Open
Abstract
PURPOSE To evaluate the effect of different veneering ceramics and veneering techniques on the bond strength to zirconia. MATERIALS AND METHODS 3Y-TZP zirconia blocks were sliced into 60 slabs, polished, and sintered. Each slab received one ceramic cylinder (Ø = 3.4 mm, 5 mm-high), according to the veneering ceramic type (feldspathic-FEL or lithium disilicate-based-LD) and the veneering technique (file-splitting with resin-based luting agent-RC, file-splitting with fusion ceramic-FC, or heat-pressing-HT), which resulted in six groups: FEL-RC, FEL-FC, FEL-HT, LD-RC, LD-FC, LD-HT. After preparation, the samples were immersed in distilled water for 24 h before the shear bond strength (SBS) test. The failure modes were classified as adhesive, predominantly adhesive, or cohesive. Representative failure mode images were taken in a Scanning Electron Microscope. The SBS data were analyzed by two-way ANOVA and Tukey's test. RESULTS Both type of veneering ceramic and technique affected the bond strength. FC led to the highest SBS values. RC and HP provided similar results when compared within each veneering ceramic. Lithium disilicate achieved lower bond strength than feldspathic ceramic when the heat-pressing technique was applied. The most frequent failure modes were predominantly adhesive and adhesive for FEL and LD, respectively. CONCLUSION File-splitting with fusion ceramic provided the highest adhesion to zirconia when feldspathic or lithium disilicate-based ceramics were used. The heat-pressing technique for veneering with lithium disilicate significantly decreased the bond strength when compared to the feldspathic ceramic.
Collapse
Affiliation(s)
- Vanessa de Fátima Nogueira
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, SP, Brazil
| | - Camila da Silva Rodrigues
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, SP, Brazil
- Graduate Program in Dentistry, Federal University of Pelotas (UFPel), Pelotas, RS, Brazil
| | - Manassés Tercio Vieira Grangeiro
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, SP, Brazil
- School of Dentistry, Anhanguera University, São José dos Campos, SP, Brazil
| | - Lisseth Patricia Claudio Contreras
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, SP, Brazil
| | - Renata Marques de Melo Marinho
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, SP, Brazil
| | - Marco Antônio Bottino
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, SP, Brazil
| |
Collapse
|
3
|
Contreras LPC, Rodrigues CS, Zucuni CP, Valandro LF, Marocho SMS, de Melo RM. Fatigue behavior of multilayer ceramic structures in traditional and reverse layering designs. J Prosthodont 2024; 33:389-395. [PMID: 37201944 DOI: 10.1111/jopr.13705] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2023] [Revised: 05/11/2023] [Accepted: 05/12/2023] [Indexed: 05/20/2023] Open
Abstract
PURPOSE This study evaluated the fatigue failure load (FFL) and the number of cycles for fatigue failure (CFF) of traditional (porcelain layer up) and reversed (zirconia layer up) designs of porcelain-veneered zirconia samples prepared with heat-pressing or file-splitting techniques. MATERIALS AND METHODS Zirconia discs were prepared and veneered with heat-pressed or machined feldspathic ceramic. The bilayer discs were bonded onto a dentin-analog according to the bilayer technique and sample design: traditional heat-pressing (T-HP), reversed heat-pressing (R-HP), traditional file-splitting with fusion ceramic (T-FC), reversed file-splitting with fusion ceramic R-FC), traditional file-splitting with resin cement (T-RC), and reversed file-splitting with resin cement (R-RC). The fatigue tests were performed using the stepwise approach at 20 Hz, 10,000 cycles/step, step-size of 200 N starting at 600 N, and proceeding until failure detection or up to 2600 N if enduring. The failure modes (from radial and/or cone cracks) were analyzed in a stereomicroscope. RESULTS The reversed design decreased the FFL and CFF of bilayers prepared with heat-pressing and file-splitting with fusion ceramic. The T-HP and T-FC reached the highest results, which were statistically similar between them. The bilayers prepared by the file-splitting with resin cement (T-RC and R-RC) were similar to the R-FC and R-HP groups regarding FFL and CFF. Almost all reverse layering samples failed by radial cracks. CONCLUSIONS The reverse layering design did not improve the fatigue behavior of porcelain veneered zirconia samples. The three bilayer techniques behaved similarly when used in the reversed design.
Collapse
Affiliation(s)
- Lisseth Patricia Claudio Contreras
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, São Paulo, Brazil
| | - Camila Silva Rodrigues
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, São Paulo, Brazil
- Graduate Program in Dentistry, Federal University of Pelotas (UFPel), Pelotas, Rio Grande do Sul, Brazil
| | - Camila Pauleski Zucuni
- Department of Restorative Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | - Luiz Felipe Valandro
- Department of Restorative Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul, Brazil
| | | | - Renata Marques de Melo
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology, São Paulo State University (UNESP), São José dos Campos, São Paulo, Brazil
| |
Collapse
|
4
|
Kumar NK, Nair A, Thomas PM, Hariprasad L, Brigit B, Merwade S, Shylaja V. Zirconia surface infiltration with low-fusing glass: A surface treatment modality to enhance the bond strength between zirconia and veneering ceramic. J Conserv Dent 2022; 25:492-497. [PMID: 36506626 PMCID: PMC9733539 DOI: 10.4103/jcd.jcd_247_22] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Revised: 05/15/2022] [Accepted: 05/19/2022] [Indexed: 12/15/2022] Open
Abstract
Background The pursuit of esthetics and superior mechanical properties prompted the layering of Yttrium stabilized Zirconia with ceramic material. However, the bioinert nature of zirconia causes the chipping off of this ceramic layer. Selective infiltration etching (SIE) of zirconia provides good bond strength between zirconia and veneering ceramic. Materials and Methods One hundred and fifty zirconia specimens of dimensions 5 × 5 × 10 mm were divided into 5 groups. Group 1: Air abrasion with 30 μ Al2O3 for 15 s with 0.4 bar pressure. Group 2: SIE and heat-induced maturation (HIM) as demonstrated by Abousheilb. Group 3: Sintered zirconia specimens were taken up for air abrasion followed by SIE/HIM. Group 4: Air abrasion and SIE performed on unsintered specimens followed by heat treatment at 1500°C. Group 5: Air abrasion performed on unsintered zirconia specimens followed by heat treatment at 1500°C followed by SIE/HIM. The samples were then layered with ceramic and subjected to shear bond strength (SBS) analysis. Results The mean and standard deviation were calculated for the data. The mean SBS among the groups was compared using ANOVA. The post hoc Bonferroni test was applied to compare between the groups. The mean SBS was highest for Group 5 (47.89 ± 6.53) followed by Group 2 (34.94 ± 3.04), Group 3 (32.56 ± 6.04), Group 1 (29.12 ± 7.37), and Group 4 (27.56 ± 7.54). ANOVA test showed statistically significant differences among the groups (F = 48.86, P = 0.00). Conclusion SIE/HIM when combined with sandblasting with appropriate heat treatment demonstrated a significant increase in bond strength. This prolongs the longevity of the restoration, thereby meeting the clinical needs.
Collapse
Affiliation(s)
- N. Kiran Kumar
- Department of Conservative Dentistry and Endodontics, Government Dental College and Research Institute, Bengaluru, Karnataka, India
| | - Anoop Nair
- Department of Prosthodontics and Implantology, Government Dental College and Research Institute, Bengaluru, Karnataka, India
| | - Priya Marian Thomas
- Department of Conservative Dentistry and Endodontics, Government Dental College and Research Institute, Bengaluru, Karnataka, India,Address for correspondence: Dr. Priya Marian Thomas, Department of Conservative Dentistry and Endodontics, Government Dental College and Research Institute, Fort, Bengaluru - 560 002, Karnataka, India. E-mail:
| | - L. Hariprasad
- Department of Conservative Dentistry and Endodontics, Government Dental College and Research Institute, Bengaluru, Karnataka, India
| | - Biji Brigit
- Department of Conservative Dentistry and Endodontics, Government Dental College and Research Institute, Bengaluru, Karnataka, India
| | - Seema Merwade
- Department of Conservative Dentistry and Endodontics, Government Dental College and Research Institute, Bengaluru, Karnataka, India
| | - V Shylaja
- Department of Conservative Dentistry and Endodontics, Government Dental College and Research Institute, Bengaluru, Karnataka, India
| |
Collapse
|
5
|
Lima JMC, Costa AKF, Anami LC, Souza KB, Silva NRD, Marinho RMDM, Borges ALS, Bottino MA, Özcan M, Souza ROA. CAD-FEA modeling and fracture resistance of bilayer zirconia crowns manufactured by the rapid layer technology. Braz Dent J 2021; 32:44-55. [PMID: 34755789 DOI: 10.1590/0103-6440202104163] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/13/2020] [Accepted: 03/29/2021] [Indexed: 11/21/2022] Open
Abstract
In the RLT (Rapid Layer Technology), veneering ceramic and framework are fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM) and then cemented to obtain the restoration. This study aimed to evaluate the effect of the thickness of veneering ceramic manufactured by the RLT technique on the fracture resistance (FR) of bilayer crowns with zirconia frameworks. Twenty zirconia frameworks and twenty feldspathic posterior crowns with two different veneering ceramic occlusal thicknesses (1mm=TF1; 2mm=TF2) were manufactured using CAD/CAM system. The specimens were luted to an epoxy resin abutment with resin cement and mechanically cycled (200N and 4.5×105 Pa, 37°C, 2×106 cycles, 3Hz). The FR test was performed (10kN, 0.5mm/min), and the specimens were analyzed in a stereomicroscope. For the stress analysis (finite element analysis, FEA), a 10kN load was equal to the in vitro test, and the principal stress was evaluated. The FR data were analyzed by Student's t-test and Weibull's analysis. The thickness influenced the FR of bilayer crowns. The FR was higher in the TF2 than in the TF1 group. The TF2 group presented the highest characteristic strength compared to the group TF1. The predominant type of failure was delamination. The FEA showed higher stress concentrations below the loading application point at the veneering cement interface in the 1-mm-thick model. The bilayer crowns manufactured using the approach of 2mm of veneering ceramic promoted higher FR compared to the group with 1mm veneering ceramic. Also, the FEA showed that the veneer ceramic thickness has an effect on stress distribution in zirconia-based bilayer crowns.
Collapse
Affiliation(s)
- Julia Magalhães Costa Lima
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology (ICT), São Paulo State University(UNESP/FOSJC), São José dos Campos, SP, Brazil
| | - Anna Karina Figueiredo Costa
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology (ICT), São Paulo State University(UNESP/FOSJC), São José dos Campos, SP, Brazil
| | - Lilian Costa Anami
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology (ICT), São Paulo State University(UNESP/FOSJC), São José dos Campos, SP, Brazil
| | - Karina Barbosa Souza
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology (ICT), São Paulo State University(UNESP/FOSJC), São José dos Campos, SP, Brazil
| | - Nathalia Ramos da Silva
- Department of Dentistry, Division of Prosthodontics, Federal University of Rio Grande do Norte, Natal, RN, Brazil
| | - Renata Marques de Melo Marinho
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology (ICT), São Paulo State University(UNESP/FOSJC), São José dos Campos, SP, Brazil
| | - Alexandre Luis Souto Borges
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology (ICT), São Paulo State University(UNESP/FOSJC), São José dos Campos, SP, Brazil
| | - Marco Antonio Bottino
- Department of Dental Materials and Prosthodontics, Institute of Science and Technology (ICT), São Paulo State University(UNESP/FOSJC), São José dos Campos, SP, Brazil
| | - Mutlu Özcan
- Dental Materials Unit, Center for Dental and Oral Medicine, Clinic for Fixed and Removable Prosthodontics and Dental Materials Science, University of Zurich, Zurich, Switzerland
| | | |
Collapse
|
6
|
Shelar P, Abdolvand H, Butler S. On the behaviour of zirconia-based dental materials: A review. J Mech Behav Biomed Mater 2021; 124:104861. [PMID: 34600431 DOI: 10.1016/j.jmbbm.2021.104861] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/10/2021] [Revised: 09/23/2021] [Accepted: 09/24/2021] [Indexed: 11/28/2022]
Abstract
Zirconia-based dental materials are extensively used in clinical practice due to their tooth-like appearance, biofunctionality, biocompatibility, and affordability. However, premature clinical failures of veneering porcelains raise a concern about their integrity. Extensive studies have been performed over a decade to resolve this issue, but it is challenging to reference all information effectively. A single source identifying the significance of potential parameters on material performance has not previously been available. An evidence-based meta-narrative review technique was used to review the characteristic parameters that can affect the overall behaviour of zirconia-based materials. Keywords were chosen to assess manuscripts based on scientific coherence with this paper's research objective. Online keyword searches were carried out on ScienceDirect, PubMed, and SAGE databases for relevant published manuscripts from year 1985-2020.261 out of 3170 identified manuscripts were included. A total of 10 parameters were identified and classified into the material, manufacturing, and geometric aspects. The effect of every parameter was reviewed on the performance of the material. A discrepancy in findings was observed and is attributed to the fact that there is no standard methodology. This review acts as a single source that summarizes various parameters' contribution to zirconia-based dental materials' performance. This review facilitates manufacturing improvements by accounting for every parameter's effect on overall performance.
Collapse
Affiliation(s)
- Prashant Shelar
- Department of Mechanical & Materials Engineering, Western University, London, Ontario, Canada
| | - Hamidreza Abdolvand
- Department of Mechanical & Materials Engineering, Western University, London, Ontario, Canada
| | - Sheila Butler
- Schulich School of Medicine & Dentistry, Western University, London, Ontario, Canada.
| |
Collapse
|
7
|
Tran L, Tam DNH, Elshafay A, Dang T, Hirayama K, Huy NT. Quality assessment tools used in systematic reviews of in vitro studies: A systematic review. BMC Med Res Methodol 2021; 21:101. [PMID: 33964880 PMCID: PMC8106836 DOI: 10.1186/s12874-021-01295-w] [Citation(s) in RCA: 43] [Impact Index Per Article: 10.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2020] [Accepted: 04/26/2021] [Indexed: 12/15/2022] Open
Abstract
BACKGROUND Systematic reviews (SRs) and meta-analyses (MAs) are commonly conducted to evaluate and summarize medical literature. This is especially useful in assessing in vitro studies for consistency. Our study aims to systematically review all available quality assessment (QA) tools employed on in vitro SRs/MAs. METHOD A search on four databases, including PubMed, Scopus, Virtual Health Library and Web of Science, was conducted from 2006 to 2020. The available SRs/MAs of in vitro studies were evaluated. DARE tool was applied to assess the risk of bias of included articles. Our protocol was developed and uploaded to ResearchGate in June 2016. RESULTS Our findings reported an increasing trend in publication of in vitro SRs/MAs from 2007 to 2020. Among the 244 included SRs/MAs, 126 articles (51.6%) had conducted the QA procedure. Overall, 51 QA tools were identified; 26 of them (51%) were developed by the authors specifically, whereas 25 (49%) were pre-constructed tools. SRs/MAs in dentistry frequently had their own QA tool developed by the authors, while SRs/MAs in other topics applied various QA tools. Many pre-structured tools in these in vitro SRs/MAs were modified from QA tools of in vivo or clinical trials, therefore, they had various criteria. CONCLUSION Many different QA tools currently exist in the literature; however, none cover all critical aspects of in vitro SRs/MAs. There is a need for a comprehensive guideline to ensure the quality of SR/MA due to their precise nature.
Collapse
Affiliation(s)
- Linh Tran
- Institute of Fundamental and Applied Sciences, Duy Tan University, Ho Chi Minh City, 700000, Vietnam
- Faculty of Natural Sciences, Duy Tan University, Da Nang City, 550000, Vietnam
| | - Dao Ngoc Hien Tam
- Asia Shine Trading & Service CO. LTD., Ho Chi Minh City, Vietnam
- Online Research Club, Nagasaki, Japan
| | - Abdelrahman Elshafay
- Online Research Club, Nagasaki, Japan
- Faculty of Medicine, Al-Azhar University, Cairo, 11884, Egypt
| | - Thao Dang
- Online Research Club, Nagasaki, Japan
- Department of Internal Medicine, Texas Tech University Health Science Center at the Permian Basin, Odessa, TX, USA
| | - Kenji Hirayama
- Department of Immunogenetics, Institute of Tropical Medicine (NEKKEN), Graduate School of Biomedical Sciences, Nagasaki University, 1-12-4 Sakamoto, Nagasaki, 852-8523, Japan
| | - Nguyen Tien Huy
- School of Tropical Medicine and Global Health, Nagasaki University, 1-12-4 Sakamoto, Nagasaki, 852-8523, Japan.
| |
Collapse
|
8
|
May MM, Fraga S, May LG. Effect of milling, fitting adjustments, and hydrofluoric acid etching on the strength and roughness of CAD-CAM glass-ceramics: A systematic review and meta-analysis. J Prosthet Dent 2021; 128:1190-1200. [PMID: 33865557 DOI: 10.1016/j.prosdent.2021.02.031] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2020] [Revised: 02/24/2021] [Accepted: 02/24/2021] [Indexed: 11/19/2022]
Abstract
STATEMENT OF PROBLEM Whether procedures performed before the cementation of computer-aided design and computer-aided manufacturing (CAD-CAM) glass-ceramic restorations, including milling, fitting adjustment, and hydrofluoric acid etching introduce defects on the ceramic surface that affect the mechanical and surface properties is unclear. PURPOSE A systematic review and meta-analysis were conducted to assess the effect of milling, fitting adjustments, and hydrofluoric acid etching (HF) on the flexural strength and roughness (Ra) of CAD-CAM glass-ceramics. MATERIAL AND METHODS Literature searches were performed up to June 2020 in the PubMed/MEDLINE, Web of Science, and Scopus databases, with no publication year or language limits. The focused question was "Do milling, fitting adjustments, and hydrofluoric acid etching affect the flexural strength and roughness of CAD-CAM glass-ceramics?" For the meta-analysis, flexural strength and Ra data on milling, fitting adjustment, and HF etching versus control (polishing) were analyzed globally. A subgroup analysis assessed the effect of etching parameters (HF concentration and time) on the flexural strength and roughness of CAD-CAM glass-ceramics with different microstructures. Comparisons were performed with random-effect models at 5% significance. RESULTS Fourteen studies from 2764 potentially relevant records were included in the qualitative syntheses, and 12 in the meta-analysis. Milling and fitting adjustments increased roughness and reduced the flexural strength of CAD-CAM glass-ceramics. The effect of HF etching was dependent on the glass-ceramic microstructure, HF concentration, and etching time. For feldspathic- and leucite-reinforced ceramics, HF 5% applied for between 30 and 120 seconds increased roughness without affecting flexural strength. For lithium disilicate glass-ceramics, HF concentrations greater than 4.9% used for 20 seconds or more reduced the strength without affecting the surface roughness. CONCLUSIONS The flexural strength of CAD-CAM glass-ceramic is reduced by grinding procedures such as milling and fitting adjustment. Ceramic microstructure, HF concentration, and etching time determined the effect of hydrofluoric acid etching on the flexural strength and surface roughness of glass-ceramic materials.
Collapse
Affiliation(s)
- Michele Mirian May
- Postgraduate student, Postgraduate Program in Dental Science, Prosthodontics Units, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| | - Sara Fraga
- Adjunct Professor, Department of Conservative Dentistry, Federal University of Rio Grande do Sul (UFRGS), Porto Alegre, Brazil.
| | - Liliana Gressler May
- Associate Professor, Department of Restorative Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Brazil
| |
Collapse
|
9
|
Roy AK, Prasad GN, Bhagat TV, Chaturvedi S, Gurumurthy V, Vyas R, Vaddamanu SK, Das G. Analysis of surface conditioning methods on core-veneer bond strength of CAD/CAM zirconia restorations. Technol Health Care 2021; 29:467-477. [PMID: 33522989 DOI: 10.3233/thc-202539] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
BACKGROUND The increased strength of zirconia has resulted in its widespread application in clinical dentistry. Nevertheless, the fracture of veneering porcelains remains one of the key reasons of failure. OBJECTIVE The objective of this study was to compare and analyze the influence of surface conditioning methods on the core-veneer bond strength of zirconia restorations. METHODS Thirty specimens of zirconia core with sizes 10 × 5 × 5 mm were layered with porcelain of sizes 5 × 3 × 3 mm. On the basis of different surface conditioning methods, four groups were made: Group I: abrasion with airborne alumina particles of 110 μm size, Group II: sandblasting with silica coated alumina particles of 50 μm in size, Group III (modified group): alteration with a coating of zirconia powder prior to sintering, and Group IV (control group): metal core specimens. The shear force of all specimens was tested using a universal testing machine with a 0.5 mm/min crosshead speed. One-way analysis of variance (ANOVA) and Tukey's post hoc pair wise comparison (p= 0.05) were performed to analyze the shear bond strength. A scanning electron microscope was used to assess the fractured specimens. RESULTS A statistically significant difference was noted between the groups. The mean value of shear bond strength was 40.25 MPa for Group I, 41.93 MPa for Group II, 48.08 MPa for Group III and 47.01 MPa for Group IV. CONCLUSIONS The modified zirconia group and control group demonstrated a significantly higher mean bond strength than that of Group I, where airborne particle abrasion was used. The scanning electron microscope showed that cohesive fracture in the porcelain veneers was the main problem of failure in altered zirconia. The modified zirconia specimens in Group III demonstrated significantly improved values of shear bond strength.
Collapse
Affiliation(s)
- Anip K Roy
- Department of Prosthodontics, Institute of Dental Sciences, Bareilly, Uttar Pradesh, India
| | - Govind N Prasad
- Dr Govind's Rama Dental Care, Guntakal, Andhra Pradesh, India
| | - Tushar V Bhagat
- College of Dentistry, Prince Sattam Bin Abdulaziz University, AlKharj, Saudi Arabia
| | - Saurabh Chaturvedi
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| | - Vishwanath Gurumurthy
- Department of Dental Technology, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia
| | - Rajesh Vyas
- Department of Dental Technology, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia
| | - Sunil K Vaddamanu
- Department of Dental Technology, College of Applied Medical Sciences, King Khalid University, Abha, Saudi Arabia
| | - Gotam Das
- Department of Prosthetic Dentistry, College of Dentistry, King Khalid University, Abha, Saudi Arabia
| |
Collapse
|
10
|
Jo EH, Huh YH, Ko KH, Park CJ, Cho LR. Effect of different ceramic materials and substructure designs on fracture resistance in anterior restorations. J Prosthet Dent 2020; 127:785-792. [PMID: 33390272 DOI: 10.1016/j.prosdent.2020.09.056] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2020] [Revised: 09/15/2020] [Accepted: 09/15/2020] [Indexed: 12/01/2022]
Abstract
STATEMENT OF PROBLEM Materials have been developed to reduce the chipping of ceramic veneer and improve the esthetics of anterior ceramic veneered restorations. However, studies of the effects of material and substructure design on fracture resistance are sparse. PURPOSE The purpose of this in vitro study was to investigate the fracture resistance of metal-ceramic (MC), zirconia-feldspathic porcelain (ZC), and zirconia-lithium disilicate (ZL) anterior restorations and evaluate the effect of material and substructure design. MATERIAL AND METHODS After preparing and scanning artificial maxillary central incisor teeth, titanium abutments and restoration specimens (n=90) were fabricated. MC, ZC, and ZL materials were prepared with substructure designs A (two-third coverage of the palatal surface) and B (one-third coverage of the palatal surface). After cementation, the specimens were thermocycled (10 000 cycles, 5 and 55 °C). Fracture load measurements, failure mode analysis, energy dispersive X-ray spectroscopy (EDS), line scan analysis, fractography, finite element analysis (FEA), and Weibull analysis were performed. Two-way ANOVA was used to identify the effects of material and substructure design on fracture load. One-way ANOVA was used to identify significant differences of fracture load (α=.05). RESULTS MC and ZL showed significantly higher fracture load than ZC (P<.05). MC_A showed a significantly higher fracture load than MC_B (P<.05). ZC_A exhibited the lowest Weibull modulus. FEA revealed that the maximum principal stress occurred near the loading area of the veneer. ZL displayed the lowest maximum principal stress among all the materials. CONCLUSIONS ZL and MC_A exhibited more favorable fracture resistance. The substructure design of MC, with increased metal coverage of the palatal surface, improved fracture resistance significantly.
Collapse
Affiliation(s)
- Eun-Hye Jo
- Graduate student, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Yoon-Hyuk Huh
- Associate Professor, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Kyung-Ho Ko
- Associate Professor, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Chan-Jin Park
- Professor, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea
| | - Lee-Ra Cho
- Professor, Department of Prosthodontics and Research Institute of Oral Science, College of Dentistry, Gangneung-Wonju National University, Gangneung, Republic of Korea.
| |
Collapse
|
11
|
Saker S, Özcan M. Effect of surface finishing and polishing procedures on color properties and translucency of monolithic zirconia restorations at varying thickness. J ESTHET RESTOR DENT 2020; 33:953-963. [PMID: 33188586 DOI: 10.1111/jerd.12681] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Accepted: 10/12/2020] [Indexed: 11/29/2022]
Abstract
OBJECTIVE This study aimed to assess the impact of monolithic zirconia thickness on its color properties after different surface finishing and polishing procedures, and following aging in coffee solution. MATERIALS AND METHODS Two types of monolithic zirconia brands [Prettau Anterior (PA) and DD Cubex2 (DDC)] with three different thicknesses: 0.5, 1, and 1.5, and 10 mm diameter were tested. The color properties were evaluated after various surface finishing procedures (glazing, adjusting with burs + glaze, polishing, adjusting with burs + polishing) and after 5,000 cycles in a coffee solution were evaluated. The differences in color (ΔE) and translucency, were calculated and statistically analyzed by three-way ANOVA and pairwise comparison (α = 0.05). RESULTS The brand, material thickness, and surface finishing protocol before and after coffee thermocycling had significant effect on color variations (p < 0.001). For translucency, 3-way ANOVA revealed a significant interaction between the material thickness and surface finishing protocol following aging in coffee solution (p < 0.001), however no significant interaction was observed following the surface finishing protocols (p = 0.247). CONCLUSIONS The optical properties of monolithic zirconia ceramics can be influenced by the material brand, material thickness and the procedure of surface finishing and polishing. CLINICAL SIGNIFICANCE Clinicians should take into consideration the potential change of the color properties of monolithic zirconia restorations following both contouring and occlusal adjustment procedures and coffee intake.
Collapse
Affiliation(s)
- Samah Saker
- Department of Fixed Prosthodontics, Mansoura University, Mansoura, Egypt
| | - Mutlu Özcan
- Division of Dental Biomaterials, Center for Dental and Oral Medicine, Clinic for Reconstructive Dentistry, University of Zürich, Zürich, Switzerland
| |
Collapse
|
12
|
Marchionatti AME, Aurélio IL, Wandscher VF. Does veneering technique affect the bond strength of bilayer Y-TZP? A systematic review and meta-analysis. J Prosthet Dent 2020; 126:480-488. [PMID: 32893018 DOI: 10.1016/j.prosdent.2020.06.008] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/30/2020] [Revised: 06/22/2020] [Accepted: 06/22/2020] [Indexed: 12/01/2022]
Abstract
STATEMENT OF PROBLEM Reasons for failures of bilayer yttria-stabilized tetragonal zirconia polycrystal (Y-TZP) restorations include the core-veneer interface bond strength. The influence of the veneering method on the bond strength of veneered Y-TZP is unclear. PURPOSE The purpose of this systematic review and meta-analysis was to evaluate the effect of the veneering method on the bond strength of bilayer Y-TZP. MATERIAL AND METHODS This review followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) statement. Searches were performed on PubMed/MEDLINE, Web of Science (Core Collection), and Scopus for in vitro studies evaluating the effect of the veneering technique on the bond strength of bilayer Y-TZP. Statistical analyses were performed with random-effect models (α=.05). RESULTS From 619 identified studies, 140 were selected for full-text analysis and 16 were included. Manual searching yielded no additional articles. The meta-analyses comprised 15 studies, and 1 study was included only in the descriptive analysis. Meta-analyses compared the hand-layered method (control) with pressed, fused, and cemented veneering methods. The fused and cemented techniques were analyzed by using subgroups assessing the veneering ceramic type (predominantly glass-ceramics and particle-filled glass-ceramics). Similar bond strength results (P=.540) were found for pressed and hand-layered veneered Y-TZP specimens. Fused veneers achieved higher bond strength values (P<.001) than the hand-layered veneers on Y-TZP frameworks, irrespective of the veneering ceramic type (predominantly glass-ceramics: P=.002; particle-filled glass-ceramics: P<.001). Global and subgroup analyses indicated that lower core-veneer bond strength values (P<.001) were found for cemented in relation to hand-layered veneers. CONCLUSIONS Core-veneer interfacial adhesion was equivalent for pressed and hand-layered veneering techniques. Improved bond strength, regardless of the veneer ceramic material type, was achieved by the fused veneering method, which seems to be a promising choice for the veneering of Y-TZP. In contrast, the cemented method may be unsuitable for veneering Y-TZP structures because of its lower bond strength than the hand-layered veneering technique.
Collapse
Affiliation(s)
| | - Iana Lamadrid Aurélio
- Voluntary Researcher, MSD and PhD Post-Graduate Program in Oral Science (Prosthodontics Unit), Faculty of Dentistry, Federal University of Santa Maria (UFSM), Santa Maria, Rio Grande do Sul State, Brazil.
| | - Vinícius Felipe Wandscher
- Adjunct Professor, Prosthodontics Unit, Faculty of Dentistry, CNEC Faculty of Santo Ângelo, Santo Ângelo, Brazil
| |
Collapse
|
13
|
Abstract
Objective: This analysis discusses common problems with systematic reviews (SRs) and presents a novel solution, the structured critical analysis (SCA) that can be incorporated into a SR or used as an alternative literature review design.Methods: A cross-sectional survey of current SRs related to interdisciplinary restorative dentistry was obtained by evaluating 100 current SRs for their self-reported methodological quality and its effect on scientific validity.Results: The preferred reporting items for systematic reviews and meta-analyses protocol (PRISMA) was used in 99/100 SRs, but only 8/100 reported a low risk of bias. High statistical heterogeneity precluding meta-analysis was found in 44/100 SRs. Only 94 paragraphs/100 SRs provided critical analysis.Discussion: Significant problems were found with current SRs that can compromise their reliability as the premier level of evidence for clinical science research. The reader must be aware of these deficiencies to correctly interpret the SR and cannot rely on the format alone.
Collapse
|
14
|
Do thermal treatments affect the mechanical behavior of porcelain-veneered zirconia? A systematic review and meta-analysis. Dent Mater 2019; 35:807-817. [PMID: 30846374 DOI: 10.1016/j.dental.2019.02.016] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/26/2018] [Accepted: 02/13/2019] [Indexed: 11/21/2022]
Abstract
OBJECTIVES A systematic review of in vitro studies was conducted to assess the effect of thermal treatments on flexural strength or critical load to failure of porcelain-veneered zirconia (PVZ). SOURCES Literature searches were performed up to June 2018 in PubMed/MEDLINE, Scopus and Web of Science databases, with no publication year or language limits. DATA From 393 relevant studies, 21 were selected for full-text analysis, from which 7 failed to meet the inclusion criteria. The 14 remaining papers were included in the systematic review: 8 for meta-analysis and 6 restricted to descriptive analyses. Hand searching of reference lists resulted in no additional papers. STUDY SELECTION In vitro studies using PVZ specimens testing the influence of thermal treatments on the fracture resistance to monotonic or cyclic loading. Papers evaluating cooling rate were divided into those applying fast cooling from above the porcelain glass transition temperature (Tg), or from below it. Meta-analyses were performed separately for flexural strength and critical load to failure, using random effects at a 5% significance level. CONCLUSIONS Delaying furnace opening at a temperature below the porcelain Tg is advised for PVZ restorations, in order to improve their fracture resistance. Additional information is required to confirm the apparent beneficial effect of self-glaze and repeated veneer firings on the mechanical properties of these restorations. Finally, in order to obtain conclusive and relevant evidence regarding thermal treatments and the fracture resistance of PVZs, future studies should concentrate on anatomically-correct crown specimens.
Collapse
|