1
|
Liulu X, Balaji P, Barber J, De Silva K, Murray T, Hickey A, Campbell T, Harris J, Gee H, Ahern V, Kumar S, Hau E, Qian PC. Radiation therapy for ventricular arrhythmias. J Med Imaging Radiat Oncol 2024. [PMID: 38698577 DOI: 10.1111/1754-9485.13662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/02/2024] [Accepted: 04/15/2024] [Indexed: 05/05/2024]
Abstract
Ventricular arrhythmias (VA) can be life-threatening arrhythmias that result in significant morbidity and mortality. Catheter ablation (CA) is an invasive treatment modality that can be effective in the treatment of VA where medications fail. Recurrence occurs commonly following CA due to an inability to deliver lesions of adequate depth to cauterise the electrical circuits that drive VA or reach areas of scar responsible for VA. Stereotactic body radiotherapy is a non-invasive treatment modality that allows volumetric delivery of energy to treat circuits that cannot be reached by CA. It overcomes the weaknesses of CA and has been successfully utilised in small clinical trials to treat refractory VA. This article summarises the current evidence for this novel treatment modality and the steps that will be required to bring it to the forefront of VA treatment.
Collapse
Affiliation(s)
- Xingzhou Liulu
- Cardiology Department, Royal North Shore Hospital, Sydney, New South Wales, Australia
| | - Poornima Balaji
- Cardiology Department, Westmead Hospital, University of Sydney, Sydney, New South Wales, Australia
- Westmead Applied Research Centre, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - Jeffrey Barber
- Department of Radiation Oncology, Crown Princess Mary Cancer Centre, Westmead Hospital, Sydney, New South Wales, Australia
- Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
| | - Kasun De Silva
- Cardiology Department, Westmead Hospital, University of Sydney, Sydney, New South Wales, Australia
- Westmead Applied Research Centre, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - Tiarne Murray
- Department of Radiation Oncology, Crown Princess Mary Cancer Centre, Westmead Hospital, Sydney, New South Wales, Australia
| | - Andrew Hickey
- Department of Radiation Oncology, Crown Princess Mary Cancer Centre, Westmead Hospital, Sydney, New South Wales, Australia
| | - Timothy Campbell
- Cardiology Department, Westmead Hospital, University of Sydney, Sydney, New South Wales, Australia
- Westmead Applied Research Centre, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
| | - Jill Harris
- Department of Radiation Oncology, Crown Princess Mary Cancer Centre, Westmead Hospital, Sydney, New South Wales, Australia
| | - Harriet Gee
- Department of Radiation Oncology, Crown Princess Mary Cancer Centre, Westmead Hospital, Sydney, New South Wales, Australia
- Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
| | - Verity Ahern
- Department of Radiation Oncology, Crown Princess Mary Cancer Centre, Westmead Hospital, Sydney, New South Wales, Australia
- Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
| | - Saurabh Kumar
- Cardiology Department, Westmead Hospital, University of Sydney, Sydney, New South Wales, Australia
- Westmead Applied Research Centre, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
- Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
| | - Eric Hau
- Department of Radiation Oncology, Crown Princess Mary Cancer Centre, Westmead Hospital, Sydney, New South Wales, Australia
- Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
- Translational Radiation Biology and Oncology Laboratory, Centre for Cancer Research, The Westmead Institute for Medical Research, Sydney, New South Wales, Australia
- Blacktown Hematology and Cancer Centre, Blacktown Hospital, Blacktown, New South Wales, Australia
| | - Pierre C Qian
- Cardiology Department, Westmead Hospital, University of Sydney, Sydney, New South Wales, Australia
- Westmead Applied Research Centre, Faculty of Medicine and Health, University of Sydney, Sydney, New South Wales, Australia
- Sydney Medical School, University of Sydney, Sydney, New South Wales, Australia
| |
Collapse
|
2
|
Pouymayou B, Perez-Haas Y, Allemann F, Saguner AM, Andratschke N, Guckenberger M, Tanadini-Lang S, Wilke L. Characterization of spatial integrity with active and passive implants in a low-field magnetic resonance linear accelerator scanner. Phys Imaging Radiat Oncol 2024; 30:100576. [PMID: 38644933 PMCID: PMC11031795 DOI: 10.1016/j.phro.2024.100576] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/04/2023] [Revised: 04/02/2024] [Accepted: 04/05/2024] [Indexed: 04/23/2024] Open
Abstract
Background and Purpose Standard imaging protocols can guarantee the spatial integrity of magnetic resonance (MR) images utilized in radiotherapy. However, the presence of metallic implants can significantly compromise this integrity. Our proposed method aims at characterizing the geometric distortions induced by both passive and active implants commonly encountered in planning images obtained from a low-field 0.35 T MR-linear accelerator (LINAC). Materials and Methods We designed a spatial integrity phantom defining 1276 control points and covering a field of view of 20x20x20 cm3. This phantom was scanned in a water tank with and without different implants used in hip and shoulder arthroplasty procedures as well as with active cardiac stimulators. The images were acquired with the clinical planning sequence (balanced steady-state free-precession, resolution 1.5x1.5x1.5 mm3). Spatial integrity was assessed by the Euclidian distance between the control point detected on the image and their theoretical locations. A first plane free of artefact (FPFA) was defined to evaluate the spatial integrity beyond the larger banding artefact. Results In the region extending up to 20 mm from the largest banding artefacts, the tested passive and active implants could cause distortions up to 2 mm and 3 mm, respectively. Beyond this region the spatial integrity was recovered and the image could be considered as unaffected by the implants. Conclusions We characterized the impact of common implants on a low field MR-LINAC planning sequence. These measurements could support the creation of extra margin while contouring organs at risk and target volumes in the vicinity of implants.
Collapse
Affiliation(s)
- Bertrand Pouymayou
- Department of Radiation Oncology, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Yoel Perez-Haas
- Department of Radiation Oncology, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Florin Allemann
- Department of Traumatology, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Ardan M. Saguner
- Department of Cardiology, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Nicolaus Andratschke
- Department of Radiation Oncology, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Matthias Guckenberger
- Department of Radiation Oncology, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Stephanie Tanadini-Lang
- Department of Radiation Oncology, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| | - Lotte Wilke
- Department of Radiation Oncology, University Hospital Zurich and University of Zurich, Zurich, Switzerland
| |
Collapse
|
3
|
Ziegler E, McCulloch J, Bassiri N, Gutierrez AN, Armas J, Abrams KJ, Mehta MP, Chuong MD, Mittauer KE. The First Report of Using Low-Field MRI-Guided Radiation Therapy in a Patient With a Cochlear Implant. Adv Radiat Oncol 2024; 9:101416. [PMID: 38406390 PMCID: PMC10882116 DOI: 10.1016/j.adro.2023.101416] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Accepted: 11/30/2023] [Indexed: 02/27/2024] Open
Affiliation(s)
- Emma Ziegler
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, Florida
| | - James McCulloch
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, Florida
- Herbert Wertheim College of Medicine, Florida International University, Miami, Florida
| | - Nema Bassiri
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, Florida
- Herbert Wertheim College of Medicine, Florida International University, Miami, Florida
| | - Alonso N. Gutierrez
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, Florida
- Herbert Wertheim College of Medicine, Florida International University, Miami, Florida
| | - Jennifer Armas
- Department of Radiology, Miami Cancer Institute, Baptist Health South Florida, Miami, Florida
| | - Kevin J. Abrams
- Department of Radiology, Miami Cancer Institute, Baptist Health South Florida, Miami, Florida
| | - Minesh P. Mehta
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, Florida
- Herbert Wertheim College of Medicine, Florida International University, Miami, Florida
| | - Michael D. Chuong
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, Florida
- Herbert Wertheim College of Medicine, Florida International University, Miami, Florida
| | - Kathryn E. Mittauer
- Department of Radiation Oncology, Miami Cancer Institute, Baptist Health South Florida, Miami, Florida
- Herbert Wertheim College of Medicine, Florida International University, Miami, Florida
| |
Collapse
|
4
|
Akdag O, Borman PTS, Mandija S, Woodhead PL, Uijtewaal P, Raaymakers BW, Fast MF. Experimental demonstration of real-time cardiac physiology-based radiotherapy gating for improved cardiac radioablation on an MR-linac. Med Phys 2024; 51:2354-2366. [PMID: 38477841 DOI: 10.1002/mp.17024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 02/09/2024] [Accepted: 02/23/2024] [Indexed: 03/14/2024] Open
Abstract
BACKGROUND Cardiac radioablation is a noninvasive stereotactic body radiation therapy (SBRT) technique to treat patients with refractory ventricular tachycardia (VT) by delivering a single high-dose fraction to the VT isthmus. Cardiorespiratory motion induces position uncertainties resulting in decreased dose conformality. Electocardiograms (ECG) are typically used during cardiac MRI (CMR) to acquire images in a predefined cardiac phase, thus mitigating cardiac motion during image acquisition. PURPOSE We demonstrate real-time cardiac physiology-based radiotherapy beam gating within a preset cardiac phase on an MR-linac. METHODS MR images were acquired in healthy volunteers (n = 5, mean age = 29.6 years, mean heart-rate (HR) = 56.2 bpm) on the 1.5 T Unity MR-linac (Elekta AB, Stockholm, Sweden) after obtaining written informed consent. The images were acquired using a single-slice balance steady-state free precession (bSSFP) sequence in the coronal or sagittal plane (TR/TE = 3/1.48 ms, flip angle = 48∘ $^{\circ }$ , SENSE = 1.5,field-of-view = 400 × 207 $\text{field-of-view} = {400}\times {207}$ mm 2 ${\text{mm}}^{2}$ , voxel size =3 × 3 × 15 $3\times 3\times 15$ mm 3 ${\rm mm}^{3}$ , partial Fourier factor = 0.65, frame rate = 13.3 Hz). In parallel, a 4-lead ECG-signal was acquired using MR-compatible equipment. The feasibility of ECG-based beam gating was demonstrated with a prototype gating workflow using a Quasar MRI4D motion phantom (IBA Quasar, London, ON, Canada), which was deployed in the bore of the MR-linac. Two volunteer-derived combined ECG-motion traces (n = 2, mean age = 26 years, mean HR = 57.4 bpm, peak-to-peak amplitude = 14.7 mm) were programmed into the phantom to mimic dose delivery on a cardiac target in breath-hold. Clinical ECG-equipment was connected to the phantom for ECG-voltage-streaming in real-time using research software. Treatment beam gating was performed in the quiescent phase (end-diastole). System latencies were compensated by delay time correction. A previously developed MRI-based gating workflow was used as a benchmark in this study. A 15-beam intensity-modulated radiotherapy (IMRT) plan (1 × 6.25 ${1}\times {6.25}$ Gy) was delivered for different motion scenarios onto radiochromic films. Next, cardiac motion was then estimated at the basal anterolateral myocardial wall via normalized cross-correlation-based template matching. The estimated motion signal was temporally aligned with the ECG-signal, which were then used for position- and ECG-based gating simulations in the cranial-caudal (CC), anterior-posterior (AP), and right-left (RL) directions. The effect of gating was investigated by analyzing the differences in residual motion at 30, 50, and 70% treatment beam duty cycles. RESULTS ECG-based (MRI-based) beam gating was performed with effective duty cycles of 60.5% (68.8%) and 47.7% (50.4%) with residual motion reductions of 62.5% (44.7%) and 43.9% (59.3%). Local gamma analyses (1%/1 mm) returned pass rates of 97.6% (94.1%) and 90.5% (98.3%) for gated scenarios, which exceed the pass rates of 70.3% and 82.0% for nongated scenarios, respectively. In average, the gating simulations returned maximum residual motion reductions of 88%, 74%, and 81% at 30%, 50%, and 70% duty cycles, respectively, in favor of MRI-based gating. CONCLUSIONS Real-time ECG-based beam gating is a feasible alternative to MRI-based gating, resulting in improved dose delivery in terms of highγ -pass $\gamma {\text{-pass}}$ rates, decreased dose deposition outside the PTV and residual motion reduction, while by-passing cardiac MRI challenges.
Collapse
Affiliation(s)
- Osman Akdag
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Pim T S Borman
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Stefano Mandija
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
- Computational Imaging Group for MR Diagnostics and Therapy, Center for Image Sciences, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Peter L Woodhead
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
- Elekta AB, Stockholm, Sweden
| | - Prescilla Uijtewaal
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Bas W Raaymakers
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Martin F Fast
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| |
Collapse
|
5
|
Curcuru AN, Yang D, An H, Cuculich PS, Robinson CG, Gach HM. Technical note: Minimizing CIED artifacts on a 0.35 T MRI-Linac using deep learning. J Appl Clin Med Phys 2024; 25:e14304. [PMID: 38368615 DOI: 10.1002/acm2.14304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Revised: 01/11/2024] [Accepted: 02/03/2024] [Indexed: 02/20/2024] Open
Abstract
BACKGROUND Artifacts from implantable cardioverter defibrillators (ICDs) are a challenge to magnetic resonance imaging (MRI)-guided radiotherapy (MRgRT). PURPOSE This study tested an unsupervised generative adversarial network to mitigate ICD artifacts in balanced steady-state free precession (bSSFP) cine MRIs and improve image quality and tracking performance for MRgRT. METHODS Fourteen healthy volunteers (Group A) were scanned on a 0.35 T MRI-Linac with and without an MR conditional ICD taped to their left pectoral to simulate an implanted ICD. bSSFP MRI data from 12 of the volunteers were used to train a CycleGAN model to reduce ICD artifacts. The data from the remaining two volunteers were used for testing. In addition, the dataset was reorganized three times using a Leave-One-Out scheme. Tracking metrics [Dice similarity coefficient (DSC), target registration error (TRE), and 95 percentile Hausdorff distance (95% HD)] were evaluated for whole-heart contours. Image quality metrics [normalized root mean square error (nRMSE), peak signal-to-noise ratio (PSNR), and multiscale structural similarity (MS-SSIM) scores] were evaluated. The technique was also tested qualitatively on three additional ICD datasets (Group B) including a patient with an implanted ICD. RESULTS For the whole-heart contour with CycleGAN reconstruction: 1) Mean DSC rose from 0.910 to 0.935; 2) Mean TRE dropped from 4.488 to 2.877 mm; and 3) Mean 95% HD dropped from 10.236 to 7.700 mm. For the whole-body slice with CycleGAN reconstruction: 1) Mean nRMSE dropped from 0.644 to 0.420; 2) Mean MS-SSIM rose from 0.779 to 0.819; and 3) Mean PSNR rose from 18.744 to 22.368. The three Group B datasets evaluated qualitatively displayed a reduction in ICD artifacts in the heart. CONCLUSION CycleGAN-generated reconstructions significantly improved both tracking and image quality metrics when used to mitigate artifacts from ICDs.
Collapse
Affiliation(s)
- Austen N Curcuru
- Department of Radiation Oncology, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Deshan Yang
- Department of Radiation Oncology, Duke University, Durham, North Carolina, USA
| | - Hongyu An
- Departments of Radiology, Biomedical Engineering and Neurology, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Phillip S Cuculich
- Departments of Cardiovascular Medicine and Radiation Oncology, Washington University in St. Louis, St. Louis, Missouri, USA
| | - Clifford G Robinson
- Department of Radiation Oncology, Washington University in St. Louis, St. Louis, Missouri, USA
| | - H Michael Gach
- Departments of Radiation Oncology, Radiology and Biomedical Engineering, Washington University in St. Louis, St. Louis, Missouri, USA
| |
Collapse
|
6
|
Poon J, Thompson RB, Deyell MW, Schellenberg D, Kohli K, Thomas S. Left ventricle segment-specific motion assessment for cardiac-gated radiosurgery. Biomed Phys Eng Express 2024; 10:025040. [PMID: 38359447 DOI: 10.1088/2057-1976/ad29a4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2023] [Accepted: 02/15/2024] [Indexed: 02/17/2024]
Abstract
Purpose.Cardiac radiosurgery is a non-invasive treatment modality for ventricular tachycardia, where a linear accelerator is used to irradiate the arrhythmogenic region within the heart. In this work, cardiac magnetic resonance (CMR) cine images were used to quantify left ventricle (LV) segment-specific motion during the cardiac cycle and to assess potential advantages of cardiac-gated radiosurgery.Methods.CMR breath-hold cine images and LV contour points were analyzed for 50 controls and 50 heart failure patients with reduced ejection fraction (HFrEF, EF < 40%). Contour points were divided into anatomic segments according to the 17-segment model, and each segment was treated as a hypothetical treatment target. The optimum treatment window (one fifth of the cardiac cycle) was determined where segment centroid motion was minimal, then the maximum centroid displacement and treatment area were determined for the full cardiac cycle and for the treatment window. Mean centroid displacement and treatment area reductions with cardiac gating were determined for each of the 17 segments.Results.Full motion segment centroid displacements ranged between 6-14 mm (controls) and 4-11 mm (HFrEF). Full motion treatment areas ranged between 129-715 mm2(controls) and 149-766 mm2(HFrEF). With gating, centroid displacements were reduced to 1 mm (controls and HFrEF), while treatment areas were reduced to 62-349 mm2(controls) and 83-393 mm2(HFrEF). Relative treatment area reduction ranged between 38%-53% (controls) and 26%-48% (HFrEF).Conclusion.This data demonstrates that cardiac cycle motion is an important component of overall target motion and varies depending on the anatomic cardiac segment. Accounting for cardiac cycle motion, through cardiac gating, has the potential to significantly reduce treatment volumes for cardiac radiosurgery.
Collapse
Affiliation(s)
- Justin Poon
- Department of Physics and Astronomy, University of British Columbia, Vancouver, BC V6T 1Z1, Canada
- Department of Medical Physics, BC Cancer, Vancouver, British Columbia V5Z 4E6, Canada
| | - Richard B Thompson
- Department of Biomedical Engineering, University of Alberta, Edmonton, AB, T6G 2V2, Canada
| | - Marc W Deyell
- Heart Rhythm Services, Division of Cardiology, University of British Columbia, Vancouver, BC V6E 1M7, Canada
| | - Devin Schellenberg
- Department of Radiation Oncology, BC Cancer, Surrey, British Columbia V3V 1Z2, Canada
| | - Kirpal Kohli
- Department of Medical Physics, BC Cancer, Surrey, British Columbia V3V 1Z2, Canada
| | - Steven Thomas
- Department of Medical Physics, BC Cancer, Vancouver, British Columbia V5Z 4E6, Canada
| |
Collapse
|
7
|
Stevens RRF, Hazelaar C, Bogowicz M, Ter Bekke RMA, Volders PGA, Verhoeven K, de Ruysscher D, Verhoeff JJC, Fast MF, Mandija S, Cvek J, Knybel L, Dvorak P, Blanck O, van Elmpt W. A Framework for Assessing the Effect of Cardiac and Respiratory Motion for Stereotactic Arrhythmia Radioablation Using a Digital Phantom With a 17-Segment Model: A STOPSTORM.eu Consortium Study. Int J Radiat Oncol Biol Phys 2024; 118:533-542. [PMID: 37652302 DOI: 10.1016/j.ijrobp.2023.08.059] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/10/2023] [Revised: 08/14/2023] [Accepted: 08/22/2023] [Indexed: 09/02/2023]
Abstract
PURPOSE The optimal motion management strategy for patients receiving stereotactic arrhythmia radioablation (STAR) for the treatment of ventricular tachycardia (VT) is not fully known. We developed a framework using a digital phantom to simulate cardiorespiratory motion in combination with different motion management strategies to gain insight into the effect of cardiorespiratory motion on STAR. METHODS AND MATERIALS The 4-dimensional (4D) extended cardiac-torso (XCAT) phantom was expanded with the 17-segment left ventricular (LV) model, which allowed placement of STAR targets in standardized ventricular regions. Cardiac- and respiratory-binned 4D computed tomography (CT) scans were simulated for free-breathing, reduced free-breathing, respiratory-gating, and breath-hold scenarios. Respiratory motion of the heart was set to population-averaged values of patients with VT: 6, 2, and 1 mm in the superior-inferior, posterior-anterior, and left-right direction, respectively. Cardiac contraction was adjusted by reducing LV ejection fraction to 35%. Target displacement was evaluated for all segments using envelopes encompassing the cardiorespiratory motion. Envelopes incorporating only the diastole plus respiratory motion were created to simulate the scenario where cardiac motion is not fully captured on 4D respiratory CT scans used for radiation therapy planning. RESULTS The average volume of the 17 segments was 6 cm3 (1-9 cm3). Cardiac contraction-relaxation resulted in maximum segment (centroid) motion of 4, 6, and 3.5 mm in the superior-inferior, posterior-anterior, and left-right direction, respectively. Cardiac contraction-relaxation resulted in a motion envelope increase of 49% (24%-79%) compared with individual segment volumes, whereas envelopes increased by 126% (79%-167%) if respiratory motion also was considered. Envelopes incorporating only the diastole and respiration motion covered on average 68% to 75% of the motion envelope. CONCLUSIONS The developed LV-segmental XCAT framework showed that free-wall regions display the most cardiorespiratory displacement. Our framework supports the optimization of STAR by evaluating the effect of (cardio)respiratory motion and motion management strategies for patients with VT.
Collapse
Affiliation(s)
- Raoul R F Stevens
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Center+, Maastricht, The Netherlands.
| | - Colien Hazelaar
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - Marta Bogowicz
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - Rachel M A Ter Bekke
- Department of Cardiology, Cardiovascular Research Institute Maastricht, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - Paul G A Volders
- Department of Cardiology, Cardiovascular Research Institute Maastricht, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - Karolien Verhoeven
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - Dirk de Ruysscher
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Center+, Maastricht, The Netherlands
| | - Joost J C Verhoeff
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Martin F Fast
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Stefano Mandija
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Jakub Cvek
- Department of Oncology, University Hospital and Faculty of Medicine, Ostrava, Czech Republic
| | - Lukas Knybel
- Department of Oncology, University Hospital and Faculty of Medicine, Ostrava, Czech Republic
| | - Pavel Dvorak
- Department of Oncology, University Hospital and Faculty of Medicine, Ostrava, Czech Republic
| | - Oliver Blanck
- Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Wouter van Elmpt
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Center+, Maastricht, The Netherlands
| |
Collapse
|
8
|
Campbell-Washburn AE, Varghese J, Nayak KS, Ramasawmy R, Simonetti OP. Cardiac MRI at Low Field Strengths. J Magn Reson Imaging 2024; 59:412-430. [PMID: 37530545 PMCID: PMC10834858 DOI: 10.1002/jmri.28890] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2023] [Revised: 06/16/2023] [Accepted: 06/16/2023] [Indexed: 08/03/2023] Open
Abstract
Cardiac MR imaging is well established for assessment of cardiovascular structure and function, myocardial scar, quantitative flow, parametric mapping, and myocardial perfusion. Despite the clear evidence supporting the use of cardiac MRI for a wide range of indications, it is underutilized clinically. Recent developments in low-field MRI technology, including modern data acquisition and image reconstruction methods, are enabling high-quality low-field imaging that may improve the cost-benefit ratio for cardiac MRI. Studies to-date confirm that low-field MRI offers high measurement concordance and consistent interpretation with clinical imaging for several routine sequences. Moreover, low-field MRI may enable specific new clinical opportunities for cardiac imaging such as imaging near metal implants, MRI-guided interventions, combined cardiopulmonary assessment, and imaging of patients with severe obesity. In this review, we discuss the recent progress in low-field cardiac MRI with a focus on technical developments and early clinical validation studies. EVIDENCE LEVEL: 5 TECHNICAL EFFICACY: Stage 1.
Collapse
Affiliation(s)
- Adrienne E Campbell-Washburn
- Cardiovascular Branch, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD USA
| | - Juliet Varghese
- Department of Biomedical Engineering, The Ohio State University, Columbus, OH, USA
| | - Krishna S Nayak
- Ming Hsieh Department of Electrical and Computer Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA
- Alfred Mann Department of Biomedical Engineering, Viterbi School of Engineering, University of Southern California, Los Angeles, California, USA
| | - Rajiv Ramasawmy
- Cardiovascular Branch, National Heart, Lung, and Blood Institute, National Institutes of Health, Bethesda MD USA
| | - Orlando P Simonetti
- Division of Cardiovascular Medicine, Department of Internal Medicine, College of Medicine, The Ohio State University, Columbus, OH, USA
- Department of Radiology, The Ohio State University, Columbus, Ohio, USA
| |
Collapse
|
9
|
Fast MF, Cao M, Parikh P, Sonke JJ. Intrafraction Motion Management With MR-Guided Radiation Therapy. Semin Radiat Oncol 2024; 34:92-106. [PMID: 38105098 DOI: 10.1016/j.semradonc.2023.10.008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2023]
Abstract
High quality radiation therapy requires highly accurate and precise dose delivery. MR-guided radiotherapy (MRgRT), integrating an MRI scanner with a linear accelerator, offers excellent quality images in the treatment room without subjecting patient to ionizing radiation. MRgRT therefore provides a powerful tool for intrafraction motion management. This paper summarizes different sources of intrafraction motion for different disease sites and describes the MR imaging techniques available to visualize and quantify intrafraction motion. It provides an overview of MR guided motion management strategies and of the current technical capabilities of the commercially available MRgRT systems. It describes how these motion management capabilities are currently being used in clinical studies, protocols and provides a future outlook.
Collapse
Affiliation(s)
- Martin F Fast
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Minsong Cao
- Department of Radiation Oncology, University of California, Los Angeles, CA
| | - Parag Parikh
- Department of Radiation Oncology, Henry Ford Health - Cancer, Detroit, MI
| | - Jan-Jakob Sonke
- Department of Radiation Oncology, The Netherlands Cancer Institute, Amsterdam, The Netherlands.
| |
Collapse
|
10
|
Kovacs B, Mayinger M, Ehrbar S, Fesslmeier D, Ahmadsei M, Sazgary L, Manka R, Alkadhi H, Ruschitzka F, Duru F, Papachristofilou A, Sticherling C, Blamek S, Gołba KS, Guckenberger M, Saguner AM, Andratschke N. Dose escalation for stereotactic arrhythmia radioablation of recurrent ventricular tachyarrhythmia - a phase II clinical trial. Radiat Oncol 2023; 18:185. [PMID: 37941012 PMCID: PMC10634182 DOI: 10.1186/s13014-023-02361-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2023] [Accepted: 10/08/2023] [Indexed: 11/10/2023] Open
Abstract
BACKGROUND Stereotactic arrhythmia radioablation (STAR) is delivered with a planning target volume (PTV) prescription dose of 25 Gy, mostly to the surrounding 75-85% isodose line. This means that the average and maximum dose received by the target is less than 35 Gy, which is the minimum threshold required to create a homogenous transmural fibrosis. Similar to catheter ablation, the primary objective of STAR should be transmural fibrosis to prevent heterogenous intracardiac conduction velocities and the occurrence of sustained ventricular arrhythmias (sVA) caused by reentry. We hypothesize that the current dose prescription used in STAR is inadequate for the long-term prevention of sVA and that a significant increase in dose is necessary to induce transmural scar formation. OBJECTIVE A single arm, multi-center, phase II, dose escalation prospective clinical trial employing the i3 + 3 design is being conducted to examine the safety of a radiation dose-escalation strategy aimed at inducing transmural scar formation. The ultimate objective of this trial is to decrease the likelihood of sVA recurrence in patients at risk. METHODS Patients with ischemic or non-ischemic cardiomyopathy and recurrent sVA, with an ICD and history of ≥ 1 catheter ablation for sVA will be included. This is a prospective, multicenter, one-arm, dose-escalation trial utilizing the i3 + 3 design, a modified 3 + 3 specifically created to overcome limitations in traditional dose-finding studies. A total of 15 patients will be recruited. The trial aims to escalate the ITV dose from 27.0 Gy to an ITV prescription dose-equivalent level of maximum 35.1 Gy by keeping the PTV prescription dose constant at 25 Gy while increasing the dose to the target (i.e. the VT substrate without PTV margin) by step-wise reduction of the prescribing isodose line (85% down to 65%). The primary outcome of this trial is safety measured by registered radiation associated adverse events (AE) up to 90 days after study intervention including radiation associated serious adverse events graded as at least 4 or 5 according to CTCAE v5, radiation pneumonitis or pericarditis requiring hospitalization and decrease in LVEF ≥ 10% as assessed by echocardiography or cardiac MRI at 90 days after STAR. The sample size was determined assuming an acceptable primary outcome event rate of 20%. Secondary outcomes include sVA burden at 6 months after STAR, time to first sVA recurrence, reduction in appropriate ICD therapies, the need for escalation of antiarrhythmic drugs, non-radiation associated safety and patient reported outcome measures such as SF-36 and EQ5D. DISCUSSION DEFT-STAR is an innovative prospective phase II trial that aims to evaluate the optimal radiation dose for STAR in patients with therapy-refractory sVA. The trial has obtained IRB approval and focuses on determining the safe and effective radiation dose to be employed in the STAR procedure. TRIAL REGISTRATION NCT05594368.
Collapse
Affiliation(s)
- Boldizsar Kovacs
- Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland
- Division of Cardiology, Department of Internal Medicine, University of Michigan, Ann Arbor, USA
- Center for Translational and Experimental Cardiology (CTEC), University of Zurich, Zurich, Switzerland
| | - Michael Mayinger
- Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland
| | - Stefanie Ehrbar
- Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland
| | - Debra Fesslmeier
- Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland
| | - Maiwand Ahmadsei
- Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland
| | - Lorraine Sazgary
- Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland
- Center for Translational and Experimental Cardiology (CTEC), University of Zurich, Zurich, Switzerland
| | - Robert Manka
- Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland
- Center for Translational and Experimental Cardiology (CTEC), University of Zurich, Zurich, Switzerland
- Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland
| | - Hatem Alkadhi
- Diagnostic and Interventional Radiology, University Hospital Zurich, Zurich, Switzerland
| | - Frank Ruschitzka
- Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland
- Center for Translational and Experimental Cardiology (CTEC), University of Zurich, Zurich, Switzerland
- Center for Integrative Human Physiology, University Zurich, Zurich, Switzerland
| | - Firat Duru
- Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland
- Center for Translational and Experimental Cardiology (CTEC), University of Zurich, Zurich, Switzerland
- Center for Integrative Human Physiology, University Zurich, Zurich, Switzerland
| | | | | | - Slawomir Blamek
- Department of Radiotherapy, Maria Skłodowska-Curie National Research Institute of Oncology, Gliwice, Poland
| | - Krzysztof S Gołba
- Department of Electrocardiology, Upper Silesian Heart Center, Medical University of Silesia, Katowice, Poland
- Department of Electrocardiology and Heart Failure, Medical University of Silesia, Katowice, Poland
| | | | - Ardan M Saguner
- Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland
- Center for Translational and Experimental Cardiology (CTEC), University of Zurich, Zurich, Switzerland
- Center for Integrative Human Physiology, University Zurich, Zurich, Switzerland
| | - Nicolaus Andratschke
- Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland.
| |
Collapse
|
11
|
Stevens RRF, Hazelaar C, Fast MF, Mandija S, Grehn M, Cvek J, Knybel L, Dvorak P, Pruvot E, Verhoeff JJC, Blanck O, van Elmpt W. Stereotactic Arrhythmia Radioablation (STAR): Assessment of cardiac and respiratory heart motion in ventricular tachycardia patients - A STOPSTORM.eu consortium review. Radiother Oncol 2023; 188:109844. [PMID: 37543057 DOI: 10.1016/j.radonc.2023.109844] [Citation(s) in RCA: 5] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Revised: 07/10/2023] [Accepted: 07/28/2023] [Indexed: 08/07/2023]
Abstract
AIM To identify the optimal STereotactic Arrhythmia Radioablation (STAR) strategy for individual patients, cardiorespiratory motion of the target volume in combination with different treatment methodologies needs to be evaluated. However, an authoritative overview of the amount of cardiorespiratory motion in ventricular tachycardia (VT) patients is missing. METHODS In this STOPSTORM consortium study, we performed a literature review to gain insight into cardiorespiratory motion of target volumes for STAR. Motion data and target volumes were extracted and summarized. RESULTS Out of the 232 studies screened, 56 provided data on cardiorespiratory motion, of which 8 provided motion amplitudes in VT patients (n = 94) and 10 described (cardiac/cardiorespiratory) internal target volumes (ITVs) obtained in VT patients (n = 59). Average cardiac motion of target volumes was < 5 mm in all directions, with maximum values of 8.0, 5.2 and 6.5 mm in Superior-Inferior (SI), Left-Right (LR), Anterior-Posterior (AP) direction, respectively. Cardiorespiratory motion of cardiac (sub)structures showed average motion between 5-8 mm in the SI direction, whereas, LR and AP motions were comparable to the cardiac motion of the target volumes. Cardiorespiratory ITVs were on average 120-284% of the gross target volume. Healthy subjects showed average cardiorespiratory motion of 10-17 mm in SI and 2.4-7 mm in the AP direction. CONCLUSION This review suggests that despite growing numbers of patients being treated, detailed data on cardiorespiratory motion for STAR is still limited. Moreover, data comparison between studies is difficult due to inconsistency in parameters reported. Cardiorespiratory motion is highly patient-specific even under motion-compensation techniques. Therefore, individual motion management strategies during imaging, planning, and treatment for STAR are highly recommended.
Collapse
Affiliation(s)
- Raoul R F Stevens
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands.
| | - Colien Hazelaar
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| | - Martin F Fast
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Stefano Mandija
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Melanie Grehn
- Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Jakub Cvek
- Department of Oncology, University Hospital and Faculty of Medicine, Ostrava, Czech Republic
| | - Lukas Knybel
- Department of Oncology, University Hospital and Faculty of Medicine, Ostrava, Czech Republic
| | - Pavel Dvorak
- Department of Oncology, University Hospital and Faculty of Medicine, Ostrava, Czech Republic
| | - Etienne Pruvot
- Heart and Vessel Department, Service of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Joost J C Verhoeff
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
| | - Oliver Blanck
- Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Wouter van Elmpt
- Department of Radiation Oncology (Maastro), GROW School for Oncology and Reproduction, Maastricht University Medical Centre+, Maastricht, the Netherlands
| |
Collapse
|
12
|
Herrera Siklody C, Schiappacasse L, Jumeau R, Reichlin T, Saguner AM, Andratschke N, Elicin O, Schreiner F, Kovacs B, Mayinger M, Huber A, Verhoeff JJC, Pascale P, Solana Muñoz J, Luca A, Domenichini G, Moeckli R, Bourhis J, Ozsahin EM, Pruvot E. Recurrences of ventricular tachycardia after stereotactic arrhythmia radioablation arise outside the treated volume: analysis of the Swiss cohort. Europace 2023; 25:euad268. [PMID: 37695314 PMCID: PMC10551232 DOI: 10.1093/europace/euad268] [Citation(s) in RCA: 3] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/06/2023] [Accepted: 05/16/2023] [Indexed: 09/12/2023] Open
Abstract
AIMS Stereotactic arrhythmia radioablation (STAR) has been recently introduced for the management of therapy-refractory ventricular tachycardia (VT). VT recurrences have been reported after STAR but the mechanisms remain largely unknown. We analysed recurrences in our patients after STAR. METHODS AND RESULTS From 09.2017 to 01.2020, 20 patients (68 ± 8 y, LVEF 37 ± 15%) suffering from refractory VT were enrolled, 16/20 with a history of at least one electrical storm. Before STAR, an invasive electroanatomical mapping (Carto3) of the VT substrate was performed. A mean dose of 23 ± 2 Gy was delivered to the planning target volume (PTV). The median ablation volume was 26 mL (range 14-115) and involved the interventricular septum in 75% of patients. During the first 6 months after STAR, VT burden decreased by 92% (median value, from 108 to 10 VT/semester). After a median follow-up of 25 months, 12/20 (60%) developed a recurrence and underwent a redo ablation. VT recurrence was located in the proximity of the treated substrate in nine cases, remote from the PTV in three cases and involved a larger substrate over ≥3 LV segments in two cases. No recurrences occurred inside the PTV. Voltage measurements showed a significant decrease in both bipolar and unipolar signal amplitude after STAR. CONCLUSION STAR is a new tool available for the treatment of VT, allowing for a significant reduction of VT burden. VT recurrences are common during follow-up, but no recurrences were observed inside the PTV. Local efficacy was supported by a significant decrease in both bipolar and unipolar signal amplitude.
Collapse
Affiliation(s)
| | - Luis Schiappacasse
- Department of Radiation Oncology, CHUV, Lausanne University Hospital, Lausanne, Switzerland
| | - Raphaël Jumeau
- Department of Radiation Oncology, CHUV, Lausanne University Hospital, Lausanne, Switzerland
| | - Tobias Reichlin
- Department of Cardiology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Ardan M Saguner
- Department of Cardiology, Universitätsspital Zürich, University Hospital Zürich, Zurich, Switzerland
| | - Nicolaus Andratschke
- Department of Radiation Oncology, Universitätsspital Zürich, University Hospital Zürich, Zurich, Switzerland
| | - Olgun Elicin
- Department of Radiation Oncology, Inselspital, Bern University Hospital and University of Bern, Bern, Switzerland
| | | | - Boldizsar Kovacs
- Department of Cardiology, Universitätsspital Zürich, University Hospital Zürich, Zurich, Switzerland
| | - Michael Mayinger
- Department of Radiation Oncology, Universitätsspital Zürich, University Hospital Zürich, Zurich, Switzerland
| | - Adrian Huber
- Department of Cardiology, Inselspital, Bern University Hospital, Bern, Switzerland
| | - Joost J C Verhoeff
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, The Netherlands
| | - Patrizio Pascale
- Department of Cardiology, CHUV, Lausanne University Hospital, Lausanne, Switzerland
| | - Jorge Solana Muñoz
- Department of Cardiology, CHUV, Lausanne University Hospital, Lausanne, Switzerland
| | - Adrian Luca
- Department of Cardiology, CHUV, Lausanne University Hospital, Lausanne, Switzerland
| | - Giulia Domenichini
- Department of Cardiology, CHUV, Lausanne University Hospital, Lausanne, Switzerland
| | - Raphael Moeckli
- Department of Radiation Oncology, CHUV, Lausanne University Hospital, Lausanne, Switzerland
| | - Jean Bourhis
- Department of Radiation Oncology, CHUV, Lausanne University Hospital, Lausanne, Switzerland
| | - Esat M Ozsahin
- Department of Radiation Oncology, CHUV, Lausanne University Hospital, Lausanne, Switzerland
| | - Etienne Pruvot
- Department of Cardiology, CHUV, Lausanne University Hospital, Lausanne, Switzerland
| |
Collapse
|
13
|
Fast MF, Lydiard S, Boda-Heggemann J, Tanadini-Lang S, Muren LP, Clark CH, Blanck O. Precision requirements in stereotactic arrhythmia radioablation for ventricular tachycardia. Phys Imaging Radiat Oncol 2023; 28:100508. [PMID: 38026083 PMCID: PMC10679852 DOI: 10.1016/j.phro.2023.100508] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/01/2023] Open
Affiliation(s)
- Martin F Fast
- Department of Radiotherapy, University Medical Center Utrecht, Utrecht, the Netherlands
| | | | - Judit Boda-Heggemann
- Department of Radiation Oncology, University Medicine Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
- DKFZ Hector Cancer Institute at the University Medical Center Mannheim, Germany
| | - Stephanie Tanadini-Lang
- Department of Radiation Oncology, University Hospital Zurich, University of Zurich, Switzerland
| | - Ludvig P Muren
- Danish Centre for Particle Therapy, Aarhus University Hospital, Aarhus, Denmark
- Department of Clinical Medicine, Aarhus University, Aarhus, Denmark
| | - Catharine H Clark
- Radiotherapy Physics, University College London Hospital, 250 Euston Rd, London NW1 2PG, UK
- Department of Medical Physics and Bioengineering, University College London, Malet Place, London WC1E 6BT, UK
- Medical Physics Dept, National Physical Laboratory, Hampton Rd, London TW11 0PX, UK
| | - Oliver Blanck
- Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Arnold-Heller-Strasse 3, Kiel 24105, Germany
| |
Collapse
|
14
|
Wang S, Luo H, Mao T, Xiang C, Hu H, Zhao J, Wang X, Wang J, Liu H, Yu L, Jiang H. Stereotactic arrhythmia radioablation: A novel therapy for cardiac arrhythmia. Heart Rhythm 2023; 20:1327-1336. [PMID: 37150313 DOI: 10.1016/j.hrthm.2023.04.052] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 08/13/2022] [Revised: 04/27/2023] [Accepted: 04/27/2023] [Indexed: 05/09/2023]
Abstract
Cardiac arrhythmia is a global health problem, and catheter ablation has been one of its main treatments for decades. However, catheter ablation is an invasive method that cannot reach the deep myocardium, and it carries a considerable risk of side effects and recurrence. Therefore, it is necessary to explore a novel approach. Stereotactic body radiotherapy, which has been widely used in the field of radiation oncology, has recently expanded in the treatment of cardiac arrhythmia; when used in this context, it is known as stereotactic arrhythmia radioablation (STAR). As a noninvasive, effective, and well-tolerated treatment, STAR may be a suitable alternative method for patients with cardiac arrhythmia who are resistant or intolerant to catheter ablation. The main particles used to deliver energy in STAR are photons, protons, and carbon ions. Most studies have shown the short-term effectiveness of STAR, but problems such as a high long-term recurrence rate with a cumulative ventricular tachycardia-free survival rate from the published literature of 38.6% and related complications have also emerged. Therefore, in this article, we review the application of stereotactic body radiotherapy in cardiac arrhythmia, analyze its potential problems, and explore methods for improvement.
Collapse
Affiliation(s)
- Songyun Wang
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, P.R. China; Cardiac Autonomic Nervous System Research Center of Wuhan University, Wuhan, P.R. China; Cardiovascular Research Institute, Wuhan University, Wuhan, P.R. China; Hubei Key Laboratory of Cardiology, Wuhan, P.R. China
| | - Hao Luo
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, P.R. China; Cardiac Autonomic Nervous System Research Center of Wuhan University, Wuhan, P.R. China; Cardiovascular Research Institute, Wuhan University, Wuhan, P.R. China; Hubei Key Laboratory of Cardiology, Wuhan, P.R. China
| | - Tianlong Mao
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, P.R. China; Cardiac Autonomic Nervous System Research Center of Wuhan University, Wuhan, P.R. China; Cardiovascular Research Institute, Wuhan University, Wuhan, P.R. China; Hubei Key Laboratory of Cardiology, Wuhan, P.R. China
| | - Chunrong Xiang
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, P.R. China; Cardiac Autonomic Nervous System Research Center of Wuhan University, Wuhan, P.R. China; Cardiovascular Research Institute, Wuhan University, Wuhan, P.R. China; Hubei Key Laboratory of Cardiology, Wuhan, P.R. China
| | - Haoyuan Hu
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, P.R. China; Cardiac Autonomic Nervous System Research Center of Wuhan University, Wuhan, P.R. China; Cardiovascular Research Institute, Wuhan University, Wuhan, P.R. China; Hubei Key Laboratory of Cardiology, Wuhan, P.R. China
| | - Jiahui Zhao
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, P.R. China; Cardiac Autonomic Nervous System Research Center of Wuhan University, Wuhan, P.R. China; Cardiovascular Research Institute, Wuhan University, Wuhan, P.R. China; Hubei Key Laboratory of Cardiology, Wuhan, P.R. China
| | - Xinqi Wang
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, P.R. China; Cardiac Autonomic Nervous System Research Center of Wuhan University, Wuhan, P.R. China; Cardiovascular Research Institute, Wuhan University, Wuhan, P.R. China; Hubei Key Laboratory of Cardiology, Wuhan, P.R. China
| | - Jiale Wang
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, P.R. China; Cardiac Autonomic Nervous System Research Center of Wuhan University, Wuhan, P.R. China; Cardiovascular Research Institute, Wuhan University, Wuhan, P.R. China; Hubei Key Laboratory of Cardiology, Wuhan, P.R. China
| | - Huafen Liu
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, P.R. China; Cardiac Autonomic Nervous System Research Center of Wuhan University, Wuhan, P.R. China; Cardiovascular Research Institute, Wuhan University, Wuhan, P.R. China; Hubei Key Laboratory of Cardiology, Wuhan, P.R. China
| | - Lilei Yu
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, P.R. China; Cardiac Autonomic Nervous System Research Center of Wuhan University, Wuhan, P.R. China; Cardiovascular Research Institute, Wuhan University, Wuhan, P.R. China; Hubei Key Laboratory of Cardiology, Wuhan, P.R. China
| | - Hong Jiang
- Department of Cardiology, Renmin Hospital of Wuhan University, Wuhan, P.R. China; Cardiac Autonomic Nervous System Research Center of Wuhan University, Wuhan, P.R. China; Cardiovascular Research Institute, Wuhan University, Wuhan, P.R. China; Hubei Key Laboratory of Cardiology, Wuhan, P.R. China.
| |
Collapse
|
15
|
Viani GA, Gouveia AG, Pavoni JF, Louie AV, Detsky J, Spratt DE, Moraes FY. A Meta-analysis of the Efficacy and Safety of Stereotactic Arrhythmia Radioablation (STAR) in Patients with Refractory Ventricular Tachycardia. Clin Oncol (R Coll Radiol) 2023; 35:611-620. [PMID: 37365062 DOI: 10.1016/j.clon.2023.04.004] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 03/24/2023] [Accepted: 04/19/2023] [Indexed: 06/28/2023]
Abstract
AIMS Reports of stereotactic arrhythmia radioablation (STAR) in patients with refractory ventricular tachycardia after catheter ablation are limited to small series. Here, we carried out a systematic review and meta-analysis of studies to better determine the efficacy and toxicity of STAR for ventricular tachycardia. MATERIALS AND METHODS Following the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) and the Meta-analyses Of Observational Studies in Epidemiology (MOOSE) guidelines, eligible studies were identified on Medline, Embase, Cochrane Library and the proceedings of annual meetings to 10 February 2023. Efficacy was defined as a ventricular tachycardia burden reduction >70% at 6 months; safety was defined as <10% of any grade ≥3 toxicity. RESULTS Seven observational studies with a total of 61 patients treated were included. At 6 months, the ventricular tachycardia burden reduction was 92% (95% confidence interval 85-100%) and use of fewer than two anti-arrhythmic drugs was seen in 85% (95% confidence interval 50-100). Six months after STAR, an 86% reduction (95% confidence interval 80-93) in the number of implantable cardioverter-defibrillator shocks was observed. The rates for improved, unchanged and decreased cardiac ejection fraction were 10%, 84% and 6%, respectively. Overall survival at 6 and 12 months was 89% (95% confidence interval 81-97) and 82% (95% confidence interval 65-98). The cardiac-specific survival at 6 months was 87%. Late grade 3 toxicity occurred in 2% (95% confidence interval 0-5%) with no grade 4-5 toxicity. CONCLUSION STAR demonstrated both satisfactory efficacy and safety for the management of refractory ventricular tachycardia and was also associated with a significant decline in anti-arrhythmic drugs consumption. These findings support the continued development of STAR as a treatment option.
Collapse
Affiliation(s)
- G A Viani
- Ribeirão Preto Medical School, Department of Medical Imaging, Hematology and Oncology of University of São Paulo (FMRP-USP), Ribeirão Preto, Brazil; Latin America Cooperative Oncology Group (LACOG), Porto Alegre, Brazil.
| | - A G Gouveia
- Latin America Cooperative Oncology Group (LACOG), Porto Alegre, Brazil; Radiation Oncology Department - Americas Oncologia, Rio de Janeiro, Brazil
| | - J F Pavoni
- Faculdade de Filosofia, Letras e Ciências Naturais, Universidade de São Paulo, Ribeirão Preto, Brazil
| | - A V Louie
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - J Detsky
- Department of Radiation Oncology, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, Ontario, Canada
| | - D E Spratt
- Department of Radiation Oncology, University Hospitals Seidman Cancer Center, Case Comprehensive Cancer Center, Cleveland, Ohio, USA
| | - F Y Moraes
- Latin America Cooperative Oncology Group (LACOG), Porto Alegre, Brazil; Department of Oncology - Division of Radiation Oncology, Kingston General Hospital, Queen's University, Kingston, Ontario, Canada
| |
Collapse
|
16
|
Morris E, Chin R, Wu T, Smith C, Nejad-Davarani S, Cao M. ASSET: Auto-Segmentation of the Seventeen SEgments for Ventricular Tachycardia Ablation in Radiation Therapy. Cancers (Basel) 2023; 15:4062. [PMID: 37627090 PMCID: PMC10452457 DOI: 10.3390/cancers15164062] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2023] [Revised: 08/03/2023] [Accepted: 08/08/2023] [Indexed: 08/27/2023] Open
Abstract
There has been a recent effort to treat high-risk ventricular tachycardia (VT) patients through radio-ablation. However, manual segmentation of the VT target is complex and time-consuming. This work introduces ASSET, or Auto-segmentation of the Seventeen SEgments for Tachycardia ablation, to aid in radiation therapy (RT) planning. ASSET was retrospectively applied to CTs for 26 thoracic RT patients (13 undergoing VT ablation). The physician-defined parasternal long-axis of the left ventricle (LV) and the axes generated from principal component analysis (PCA) were compared using mean distance to agreement (MDA) and angle of separation. The manually selected right ventricle insertion point and LVs were used to apply the ASSET model to automatically generate the 17 segments of the LV myocardium (LVM). Physician-defined parasternal long-axis differed from PCA by 1.2 ± 0.3 mm MDA and 6.9 ± 0.7 degrees. Segments differed by 0.69 ± 0.29 mm MDA and 0.89 ± 0.03 Dice similarity coefficient. Running ASSET takes <5 min where manual segmentation took >2 h/patient. Agreement between ASSET and expert contours was comparable to inter-observer variability. Qualitative scoring conducted by three experts revealed automatically generated segmentations were clinically useable as-is. ASSET offers efficient and reliable automatic segmentations for the 17 segments of the LVM for target generation in RT planning.
Collapse
Affiliation(s)
- Eric Morris
- Department of Radiation Oncology, Washington University, St. Louis, MO 63110, USA
| | - Robert Chin
- Department of Radiation Oncology, UCLA Health, Los Angeles, CA 90095, USA; (R.C.); (T.W.); (C.S.)
| | - Trudy Wu
- Department of Radiation Oncology, UCLA Health, Los Angeles, CA 90095, USA; (R.C.); (T.W.); (C.S.)
| | - Clayton Smith
- Department of Radiation Oncology, UCLA Health, Los Angeles, CA 90095, USA; (R.C.); (T.W.); (C.S.)
| | - Siamak Nejad-Davarani
- Department of Radiation Oncology, University of Miami Miller School of Medicine, Miami, FL 33136, USA;
| | - Minsong Cao
- Department of Radiation Oncology, UCLA Health, Los Angeles, CA 90095, USA; (R.C.); (T.W.); (C.S.)
| |
Collapse
|
17
|
Ladbury C, Amini A, Schwer A, Liu A, Williams T, Lee P. Clinical Applications of Magnetic Resonance-Guided Radiotherapy: A Narrative Review. Cancers (Basel) 2023; 15:cancers15112916. [PMID: 37296879 DOI: 10.3390/cancers15112916] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 05/20/2023] [Accepted: 05/23/2023] [Indexed: 06/12/2023] Open
Abstract
Magnetic resonance-guided radiotherapy (MRgRT) represents a promising new image guidance technology for radiation treatment delivery combining an onboard MRI scanner with radiation delivery technology. By enabling real-time low-field or high-field MRI acquisition, it facilitates improved soft tissue delineation, adaptive treatment, and motion management. Now that MRgRT has been available for nearly a decade, research has shown the technology can be used to effectively shrink treatment margins to either decrease toxicity (in breast, prostate cancer, and pancreatic cancer) or facilitate dose-escalation and improved oncologic outcomes (in pancreatic and liver cancer), as well as enabling indications that require clear soft tissue delineation and gating (lung and cardiac ablation). In doing so, the use of MRgRT has the potential to significantly improve the outcomes and quality of life of the patients it treats. The present narrative review aims to describe the rationale for MRgRT, the current and forthcoming state of technology, existing studies, and future directions for the advancement of MRgRT, including associated challenges.
Collapse
Affiliation(s)
- Colton Ladbury
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA 91010, USA
| | - Arya Amini
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA 91010, USA
| | - Amanda Schwer
- Department of Radiation Oncology, City of Hope Orange County Lennar Foundation Cancer Center, Irvine, CA 92618, USA
| | - An Liu
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA 91010, USA
| | - Terence Williams
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA 91010, USA
| | - Percy Lee
- Department of Radiation Oncology, City of Hope Orange County Lennar Foundation Cancer Center, Irvine, CA 92618, USA
| |
Collapse
|
18
|
Mehrhof F, Bergengruen P, Gerds-Li JH, Jahn A, Kluge AK, Parwani A, Zips D, Boldt LH, Schönrath F. Cardiac radioablation of incessant ventricular tachycardia in patients with terminal heart failure under permanent left ventricular assist device therapy-description of two cases. Strahlenther Onkol 2023; 199:511-519. [PMID: 36750509 PMCID: PMC10133058 DOI: 10.1007/s00066-023-02045-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Accepted: 01/08/2023] [Indexed: 02/09/2023]
Abstract
PURPOSE Cardiac radioablation (cRA) using a stereotactic single-session radioablative approach has recently been described as a possible treatment option for patients with otherwise untreatable recurrent ventricular tachycardia (VT). There is very limited experience in cRA for patients undergoing left ventricular assist device (LVAD) therapy. We present clinical experiences of two patients treated with cRA for incessant VT under long-term LVAD therapy. METHODS Two male patients (54 and 61 years old) with terminal heart failure under LVAD therapy (both patients for 8 years) showed incessant VT despite extensive antiarrhythmic drug therapy and repeated catheter ablation. cRA with a single dose of 25 Gy was applied as a last resort strategy under compassionate use in both patients following an electroanatomical mapping procedure. RESULTS Both patients displayed ongoing VT during and after the cRA procedure. Repeated attempts at post-procedural rhythm conversion failed in both patients; however, one patient was hemodynamically stabilized and could be discharged home for several months before falling prey to a fatal bleeding complication. The second patient initially stabilized for a few days following cRA before renewed acceleration of running VT required bilateral ablation of the stellate ganglion; the patient died 50 days later. No immediate side effects of cRA were detected in either patient. CONCLUSION cRA might serve as a last resort strategy for patients with terminal heart failure undergoing LVAD therapy and displaying incessant VT. Intermediate- and long-term outcomes of these seriously ill patients often remain poor; therefore, best supportive care strategies should also be evaluated as long as no clear beneficial effects of cRA procedures can be shown. For patients treated with cRA under running ventricular rhythm abnormality, strategies for post-procedural generation of stabilized rhythm have to be established.
Collapse
Affiliation(s)
- Felix Mehrhof
- Department for Radiation Oncology, Charité-University Medicine Berlin, Berlin, Germany.
| | - Paula Bergengruen
- Department for Radiation Oncology, Charité-University Medicine Berlin, Berlin, Germany
| | - Jin-Hong Gerds-Li
- Department of Cardiothoracic and Vascular Surgery, German Heart Institute Berlin, Berlin, Germany
| | - Andrea Jahn
- Department of Cardiothoracic and Vascular Surgery, German Heart Institute Berlin, Berlin, Germany
| | - Anne Kathrin Kluge
- Department for Radiation Oncology, Charité-University Medicine Berlin, Berlin, Germany
| | - Abdul Parwani
- Department for Cardiology, Charité-University Medicine Berlin, Berlin, Germany
| | - Daniel Zips
- Department for Radiation Oncology, Charité-University Medicine Berlin, Berlin, Germany
| | - Leif-Hendrik Boldt
- Department for Cardiology, Charité-University Medicine Berlin, Berlin, Germany
| | - Felix Schönrath
- Department of Cardiothoracic and Vascular Surgery, German Heart Institute Berlin, Berlin, Germany
- DZHK (German Center for Cardiovascular Research) Partnersite Berlin, Berlin, Germany
- Charité-University Medicine Berlin, Berlin, Germany
| |
Collapse
|
19
|
Guarracini F, Tritto M, Di Monaco A, Mariani MV, Gasperetti A, Compagnucci P, Muser D, Preda A, Mazzone P, Themistoclakis S, Carbucicchio C. Stereotactic Arrhythmia Radioablation Treatment of Ventricular Tachycardia: Current Technology and Evolving Indications. J Cardiovasc Dev Dis 2023; 10:jcdd10040172. [PMID: 37103051 PMCID: PMC10143260 DOI: 10.3390/jcdd10040172] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/21/2023] [Revised: 04/12/2023] [Accepted: 04/15/2023] [Indexed: 04/28/2023] Open
Abstract
Ventricular tachycardia in patients with structural heart disease is a significant cause of morbidity and mortality. According to current guidelines, cardioverter defibrillator implantation, antiarrhythmic drugs, and catheter ablation are established therapies in the management of ventricular arrhythmias but their efficacy is limited in some cases. Sustained ventricular tachycardia can be terminated by cardioverter-defibrillator therapies although shocks in particular have been demonstrated to increase mortality and worsen patients' quality of life. Antiarrhythmic drugs have important side effects and relatively low efficacy, while catheter ablation, even if it is actually an established treatment, is an invasive procedure with intrinsic procedural risks and is frequently affected by patients' hemodynamic instability. Stereotactic arrhythmia radioablation for ventricular arrhythmias was developed as bail-out therapy in patients unresponsive to traditional treatments. Radiotherapy has been mainly applied in the oncological field, but new current perspectives have developed in the field of ventricular arrhythmias. Stereotactic arrhythmia radioablation provides an alternative non-invasive and painless therapeutic strategy for the treatment of previously detected cardiac arrhythmic substrate by three-dimensional intracardiac mapping or different tools. Since preliminary experiences have been reported, several retrospective studies, registries, and case reports have been published in the literature. Although, for now, stereotactic arrhythmia radioablation is considered an alternative palliative treatment for patients with refractory ventricular tachycardia and no other therapeutic options, this research field is currently extremely promising.
Collapse
Affiliation(s)
| | - Massimo Tritto
- Electrophysiology and Cardiac Pacing Unit, Humanitas Mater Domini Hospital, 21053 Castellanza, Italy
| | - Antonio Di Monaco
- Cardiology Department, General Regional Hospital F. Miulli, 70021 Acquaviva delle Fonti, Italy
| | - Marco Valerio Mariani
- Department of Cardiovascular, Respiratory, Nephrology, Anaesthesiology and Geriatric Sciences, Sapienza University of Rome, 00100 Rome, Italy
| | - Alessio Gasperetti
- Department of Cardiology, ASST-Fatebenefratelli Sacco, Luigi Sacco Hospital, University of Milan, 20157 Milan, Italy
| | - Paolo Compagnucci
- Cardiology and Arrhythmology Clinic, University Hospital Ospedali Riuniti Umberto I-Lancisi-Salesi, 60126 Ancona, Italy
| | - Daniele Muser
- Cardiothoracic Department, University Hospital, 33100 Udine, Italy
| | - Alberto Preda
- Department of Cardiac Electrophysiology and Arrhythmology, IRCCS San Raffaele Hospital, 20132 Milan, Italy
| | - Patrizio Mazzone
- Cardiothoracovascular Department, Electrophysiology Unit, Niguarda Hospital, 20162 Milan, Italy
| | - Sakis Themistoclakis
- Department of Cardiothoracic, Vascular Medicine and Intensive Care, Dell'Angelo Hospital, Mestre, 30174 Venice, Italy
| | - Corrado Carbucicchio
- Department of Clinical Electrophysiology and Cardiac Pacing, Centro Cardiologico Monzino IRCCS, 20138 Milan, Italy
| |
Collapse
|
20
|
Chuong MD, Palm RF, Tjong MC, Hyer DE, Kishan AU. Advances in MRI-Guided Radiation Therapy. Surg Oncol Clin N Am 2023; 32:599-615. [PMID: 37182995 DOI: 10.1016/j.soc.2023.02.008] [Citation(s) in RCA: 2] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/07/2023]
Abstract
Image guidance for radiation therapy (RT) has evolved over the last few decades and now is routinely performed using cone-beam computerized tomography (CBCT). Conventional linear accelerators (LINACs) that use CBCT have limited soft tissue contrast, are not able to image the patient's internal anatomy during treatment delivery, and most are not capable of online adaptive replanning. RT delivery systems that use MRI have become available within the last several years and address many of the imaging limitations of conventional LINACs. Herein, the authors review the technical characteristics and advantages of MRI-guided RT as well as emerging clinical outcomes.
Collapse
Affiliation(s)
- Michael D Chuong
- Department of Radiation Oncology, Miami Cancer Institute, 8900 North Kendall Drive, Miami, FL 33176, USA.
| | - Russell F Palm
- Department of Radiation Oncology, Moffitt Cancer Center, 12902 USF Magnolia Drive, Tampa, FL 33612, USA
| | - Michael C Tjong
- Department of Radiation Oncology, Dana-Farber Cancer Institute, 450 Brookline Avenue, Boston, MA 02215, USA
| | - Daniel E Hyer
- Department of Radiation Oncology, University of Iowa, 200 Hawkins Dr, Iowa City, IA 52242, USA
| | - Amar U Kishan
- Department of Radiation Oncology, University of California Los Angeles, 1338 S Hope Street, Los Angeles, CA 90015, USA
| |
Collapse
|
21
|
Huang SH, Wu YW, Shueng PW, Wang SY, Tsai MC, Liu YH, Chuang WP, Lin HH, Tien HJ, Yeh HP, Hsieh CH. Case report: Stereotactic body radiation therapy with 12 Gy for silencing refractory ventricular tachycardia. Front Cardiovasc Med 2022; 9:973105. [PMID: 36407435 PMCID: PMC9669661 DOI: 10.3389/fcvm.2022.973105] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2022] [Accepted: 10/17/2022] [Indexed: 10/25/2023] Open
Abstract
BACKGROUND Encouraging results have been reported for the treatment of ventricular tachycardia (VT) with stereotactic body radiation therapy (SBRT) with 25 Gy. SBRT with 12 Gy for refractory VT was designed to reduce long-term cardiac toxicity. METHODS Stereotactic body radiation therapy-VT simulation, planning, and treatment were performed using standard techniques. A patient was treated with a marginal dose of 12 Gy in a single fraction to the planning target volume (PTV). The goal was for at least ≥ 95% of the PTV to be covered by at least 95% of 12 Gy radiation. RESULTS From April 2021 through June 2022, a patient with refractory VT underwent treatment. The volume for PTV was 65.8 cm3. The mean radiation dose administered to the heart (the heart volume excluding the PTV) was 2.2 Gy. No acute or late toxicity was observed after SBRT. Six months after SBRT, the patient experienced new monomorphic right ventricular outflow tract (RVOT) VT. Interestingly, the substrate of the left ventricular basal to middle posteroseptal wall before SBRT was turned into scar zones with a local voltage < 0.5 mV. Catheter ablation to treat RVOT VT was performed, and the situation remains stable to date. CONCLUSION This study reports the first patient with refractory VT successfully treated with 12.0 Gy SBRT, suggesting that 12 Gy is a potential dose to treat refractory VT. Further investigations and enrollment of more patients are warranted to assess the long-term efficacy and side effects of this treatment.
Collapse
Affiliation(s)
- Shan-Hui Huang
- Division of Cardiology, Cardiovascular Medical Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Yen-Wen Wu
- Division of Cardiology, Cardiovascular Medical Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan
- School of Medicine, National Yang Ming Chiao Tung University, Taipei City, Taiwan
- Department of Nuclear Medicine Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Pei-Wei Shueng
- School of Medicine, National Yang Ming Chiao Tung University, Taipei City, Taiwan
- Division of Radiation Oncology, Department of Radiology, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Shan-Ying Wang
- Department of Nuclear Medicine Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan
- Department of Biomedical Imaging and Radiological Sciences, National Yang Ming Chiao Tung University, Taipei City, Taiwan
| | - Meng-Chieh Tsai
- Division of Radiology, Department of Radiology, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Yuan-Hung Liu
- Division of Cardiology, Cardiovascular Medical Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan
- Department of Electronic Engineering, Asia Eastern University of Science and Technology, New Taipei City, Taiwan
| | - Wen-Po Chuang
- Division of Cardiology, Cardiovascular Medical Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Heng-Hsu Lin
- Division of Cardiology, Cardiovascular Medical Center, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Hui-Ju Tien
- Division of Radiation Oncology, Department of Radiology, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Hsin-Pei Yeh
- Division of Radiation Oncology, Department of Radiology, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| | - Chen-Hsi Hsieh
- School of Medicine, National Yang Ming Chiao Tung University, Taipei City, Taiwan
- Division of Radiation Oncology, Department of Radiology, Far Eastern Memorial Hospital, New Taipei City, Taiwan
- School of Medicine, Institute of Traditional Medicine, National Yang Ming Chiao Tung University, Taipei City, Taiwan
- Head and Neck Cancer Surveillance and Research Group, Far Eastern Memorial Hospital, New Taipei City, Taiwan
| |
Collapse
|
22
|
Cozzi S, Bottoni N, Botti A, Trojani V, Alì E, Finocchi Ghersi S, Cremaschi F, Iori F, Ciammella P, Iori M, Iotti C. The Use of Cardiac Stereotactic Radiation Therapy (SBRT) to Manage Ventricular Tachycardia: A Case Report, Review of the Literature and Technical Notes. J Pers Med 2022; 12:jpm12111783. [PMID: 36579492 PMCID: PMC9694192 DOI: 10.3390/jpm12111783] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2022] [Revised: 10/11/2022] [Accepted: 10/24/2022] [Indexed: 01/01/2023] Open
Abstract
BACKGROUND among cardiac arrhythmias, ventricular tachycardia (VT) is one that can lead to cardiac death, although significant progress has been made in its treatment, including the use of implantable cardioverter-defibrillators (ICD) and radiofrequency catheter ablation. Nevertheless, long-term recurrence rates remain in about half of patients and drastically impact the patient's quality of life. Moreover, recurrent ICD shocks are painful and are associated with higher mortality and worsening of heart failure. Recently, more and more experiences are demonstrating potential efficacy in the use of stereotactic body radiotherapy (SBRT) (also called cardiac radio-ablation) to treat this condition. In this paper, we report our experience in the use of cardiac radio-ablation for the treatment of refractory ventricular tachycardia with a focus on the technique used, along with a review of the literature and technical notes. CASE PRESENTATION an 81-year-old male patient with a long history of non-ischemic dilated cardiomyopathy and mechanical mitral prosthesis underwent a biventricular cardioverter defibrillator implant after atrial ventricular node ablation. At the end of 2021, the number of tachycardias increased significantly to about 10 episodes per day. After failure of medical treatment and conventional RT catheter ablation, the patient was treated with SBRT for a total dose of 25 Gy in a single session at the site of the ectopic focus. No acute toxicity was recorded. After SBRT (follow-up 7 months) no other VT episodes were recorded. CONCLUSION SBRT appears to be safe and leads to a rapid reduction in arrhythmic storms as treatment for VT without acute toxicity, representing one of the most promising methods for treating VT storms.
Collapse
Affiliation(s)
- Salvatore Cozzi
- Radiation Oncology Unit, Azienda USL-IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
| | - Nicola Bottoni
- Department of Cardiology, Arrhythmology Center, Azienda USL-IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
| | - Andrea Botti
- Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
- Correspondence:
| | - Valeria Trojani
- Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
| | - Emanuele Alì
- Radiation Oncology Unit, Azienda USL-IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
| | - Sebastiano Finocchi Ghersi
- Radiation Oncolgy Unit, AOU Sant’Andrea, Facoltà di Medicina e Psicologia, Università La Sapienza, 00185 Rome, Italy
| | - Federica Cremaschi
- Engineer Clinical Specialist, Biosense Webster, Pratica di Mare, Pomezia, 00071 Rome, Italy
| | - Federico Iori
- Radiation Oncology Unit, Azienda USL-IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
| | - Patrizia Ciammella
- Radiation Oncology Unit, Azienda USL-IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
| | - Mauro Iori
- Medical Physics Unit, Azienda USL-IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
| | - Cinzia Iotti
- Radiation Oncology Unit, Azienda USL-IRCCS di Reggio Emilia, 42123 Reggio Emilia, Italy
| |
Collapse
|
23
|
Kovacs B, Mayinger M, Andratschke N, Saguner AM. Stereotactic arrhythmia radioablation: competitor or adjunct to catheter ablation? Eur Heart J 2022; 43:3279-3281. [PMID: 35947872 DOI: 10.1093/eurheartj/ehac435] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/13/2022] Open
Affiliation(s)
- Boldizsar Kovacs
- Arrhythmia Unit, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland.,Department of Internal Medicine, University of Michigan, Ann Arbor, MI, USA
| | - Michael Mayinger
- Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland
| | - Nicolaus Andratschke
- Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland
| | - Ardan M Saguner
- Arrhythmia Unit, Department of Cardiology, University Heart Center, University Hospital Zurich, Zurich, Switzerland
| |
Collapse
|
24
|
Shangguan W, Xu G, Wang X, Zhang N, Liu X, Li G, Tse G, Liu T. Stereotactic Radiotherapy: An Alternative Option for Refractory Ventricular Tachycardia to Drug and Ablation Therapy. J Clin Med 2022; 11:jcm11123549. [PMID: 35743614 PMCID: PMC9225049 DOI: 10.3390/jcm11123549] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2022] [Revised: 06/01/2022] [Accepted: 06/15/2022] [Indexed: 11/16/2022] Open
Abstract
Refractory ventricular tachycardia (VT) often occurs in the context of organic heart disease. It is associated with significantly high mortality and morbidity rates. Antiarrhythmic drugs and catheter ablation represent the two main treatment options for refractory VT, but their use can be associated with inadequate therapeutic responses and procedure-related complications. Stereotactic body radiotherapy (SBRT) is extensively applied in the precision treatment of solid tumors, with excellent therapeutic responses. Recently, this highly precise technology has been applied for radioablation of VT, and its early results demonstrate a favorable safety profile. This review presents the potential value of SBRT in refractory VT.
Collapse
Affiliation(s)
- Wenfeng Shangguan
- Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular Disease, Department of Cardiology, Tianjin Institute of Cardiology, Second Hospital of Tianjin Medical University, Tianjin 300211, China; (W.S.); (G.X.); (X.W.); (N.Z.); (G.L.)
| | - Gang Xu
- Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular Disease, Department of Cardiology, Tianjin Institute of Cardiology, Second Hospital of Tianjin Medical University, Tianjin 300211, China; (W.S.); (G.X.); (X.W.); (N.Z.); (G.L.)
| | - Xin Wang
- Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular Disease, Department of Cardiology, Tianjin Institute of Cardiology, Second Hospital of Tianjin Medical University, Tianjin 300211, China; (W.S.); (G.X.); (X.W.); (N.Z.); (G.L.)
| | - Nan Zhang
- Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular Disease, Department of Cardiology, Tianjin Institute of Cardiology, Second Hospital of Tianjin Medical University, Tianjin 300211, China; (W.S.); (G.X.); (X.W.); (N.Z.); (G.L.)
| | - Xingpeng Liu
- Department of Heart Center, Beijing Chaoyang Hospital, Capital Medical University, 8th Gongtinanlu Rd., Chaoyang District, Beijing 100020, China;
| | - Guangping Li
- Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular Disease, Department of Cardiology, Tianjin Institute of Cardiology, Second Hospital of Tianjin Medical University, Tianjin 300211, China; (W.S.); (G.X.); (X.W.); (N.Z.); (G.L.)
| | - Gary Tse
- Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular Disease, Department of Cardiology, Tianjin Institute of Cardiology, Second Hospital of Tianjin Medical University, Tianjin 300211, China; (W.S.); (G.X.); (X.W.); (N.Z.); (G.L.)
- Faculty of Health and Medical Sciences, University of Surrey, Guildford GU2 7XH, UK
- Kent and Medway Medical School, Canterbury CT2 7FS, UK
- Correspondence: (G.T.); (T.L.)
| | - Tong Liu
- Tianjin Key Laboratory of Ionic-Molecular Function of Cardiovascular Disease, Department of Cardiology, Tianjin Institute of Cardiology, Second Hospital of Tianjin Medical University, Tianjin 300211, China; (W.S.); (G.X.); (X.W.); (N.Z.); (G.L.)
- Correspondence: (G.T.); (T.L.)
| |
Collapse
|
25
|
Kluge A, Ehrbar S, Grehn M, Fleckenstein J, Baus WW, Siebert FA, Schweikard A, Andratschke N, Mayinger MC, Boda-Heggemann J, Buergy D, Celik E, Krug D, Kovacs B, Saguner AM, Rudic B, Bergengruen P, Boldt LH, Stauber A, Zaman A, Bonnemeier H, Dunst J, Budach V, Blanck O, Mehrhof F. Treatment Planning for Cardiac Radioablation: Multicenter Multiplatform Benchmarking for the XXX Trial. Int J Radiat Oncol Biol Phys 2022; 114:360-372. [PMID: 35716847 DOI: 10.1016/j.ijrobp.2022.06.056] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/03/2022] [Revised: 05/15/2022] [Accepted: 06/05/2022] [Indexed: 10/18/2022]
Abstract
PURPOSE Cardiac radioablation is a novel treatment option for patients with refractory ventricular tachycardia (VT) unsuitable for catheter ablation. The quality of treatment planning depends on dose specifications, platform capabilities, and experience of the treating staff. To harmonize the treatment planning, benchmarking of this process is necessary for multicenter clinical studies such as the XXX trial. METHODS AND MATERIALS Planning computed tomography data and consensus structures from three patients were sent to five academic centers for independent plan development using a variety of platforms and techniques with the XXX study protocol serving as guideline. Three-dimensional dose distributions and treatment plan details were collected and analyzed. In addition, an objective relative plan quality ranking system for VT treatments was established. RESULTS For each case, three coplanar volumetric modulated arc (VMAT) plans for C-arm linear accelerators (LINAC) and three non-coplanar treatment plans for robotic arm LINAC were generated. All plans were suitable for clinical applications with minor deviations from study guidelines in most centers. Eleven of 18 treatment plans showed maximal one minor deviation each for target and cardiac substructures. However, dose-volume histograms showed substantial differences: in one case, the PTV≥30Gy ranged from 0.0% to 79.9% and the RIVA V14Gy ranged from 4.0% to 45.4%. Overall, the VMAT plans had steeper dose gradients in the high dose region, while the plans for the robotic arm LINAC had smaller low dose regions. Thereby, VMAT plans required only about half as many monitor units, resulting in shorter delivery times, possibly an important factor in treatment outcome. CONCLUSIONS Cardiac radioablation is feasible with robotic arm and C-arm LINAC systems with comparable plan quality. Although cross-center training and best practice guidelines have been provided, further recommendations, especially for cardiac substructures, and ranking of dose guidelines will be helpful to optimize cardiac radioablation outcomes.
Collapse
Affiliation(s)
- Anne Kluge
- Klinik für Radioonkologie und Strahlentherapie, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Stefanie Ehrbar
- Klinik für Radio-Onkologie, UniversitätsSpital Zürich, University of Zurich, Zürich, CH
| | - Melanie Grehn
- Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Jens Fleckenstein
- Department of Radiation Oncology, Universitätsmedizin Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Wolfgang W Baus
- Department of Radiation Oncology and Cyberknife Center, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Frank-Andre Siebert
- Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Achim Schweikard
- University of Lübeck, Institute for Robotic and Cognitive Systems, Lübeck, Germany
| | - Nicolaus Andratschke
- Klinik für Radio-Onkologie, UniversitätsSpital Zürich, University of Zurich, Zürich, CH
| | - Michael C Mayinger
- Klinik für Radio-Onkologie, UniversitätsSpital Zürich, University of Zurich, Zürich, CH
| | - Judit Boda-Heggemann
- Department of Radiation Oncology, Universitätsmedizin Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Daniel Buergy
- Department of Radiation Oncology, Universitätsmedizin Mannheim, Medical Faculty Mannheim, Heidelberg University, Mannheim, Germany
| | - Eren Celik
- Department of Radiation Oncology and Cyberknife Center, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - David Krug
- Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Boldizsar Kovacs
- Universitäres Herzzentrum, Klinik für Kardiologie, UniversitätsSpital Zürich, University of Zurich, Zürich, CH
| | - Ardan M Saguner
- Universitäres Herzzentrum, Klinik für Kardiologie, UniversitätsSpital Zürich, University of Zurich, Zürich, CH
| | - Boris Rudic
- Medizinische Klinik, Universitätsmedizin Mannheim and German Center for Cardiovascular Research (DZHK), Partner Site Heidelberg/Mannheim, Mannheim, Germany
| | - Paula Bergengruen
- Klinik für Radioonkologie und Strahlentherapie, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Leif-Hendrik Boldt
- Med. Klinik m.S. Kardiologie, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Annina Stauber
- Department of Radiation Oncology and Cyberknife Center, Faculty of Medicine and University Hospital Cologne, University of Cologne, Cologne, Germany
| | - Adrian Zaman
- Klinik für Innere Medizin III, Abteilung für Elektrophysiologie und Rhythmologie, Universitätsklinikum Schleswig-Holstein, Kiel, Germany
| | - Hendrik Bonnemeier
- Klinik für Innere Medizin III, Abteilung für Elektrophysiologie und Rhythmologie, Universitätsklinikum Schleswig-Holstein, Kiel, Germany
| | - Jürgen Dunst
- Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Volker Budach
- Klinik für Radioonkologie und Strahlentherapie, Charité - Universitätsmedizin Berlin, Berlin, Germany
| | - Oliver Blanck
- Department of Radiation Oncology, University Medical Center Schleswig-Holstein, Kiel, Germany
| | - Felix Mehrhof
- Klinik für Radioonkologie und Strahlentherapie, Charité - Universitätsmedizin Berlin, Berlin, Germany.
| |
Collapse
|
26
|
Molon G, Giaj-Levra N, Costa A, Bonapace S, Cuccia F, Marinelli A, Trachanas K, Sicignano G, Alongi F. Stereotactic ablative radiotherapy in patients with refractory ventricular tachyarrhythmia. Eur Heart J Suppl 2022; 24:C248-C253. [PMID: 35602256 PMCID: PMC9117912 DOI: 10.1093/eurheartj/suac016] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Abstract
Stereotactic ablative body radiotherapy (SABR) is an innovative therapeutic approach in patients (pts) with a diagnosis of refractory ventricular tachyarrhythmia (VT) after the use of drugs, radiofrequency catheter ablation, and/or defibrillator (ICD) implant. The current efficacy data of SABR are limited and several prospective clinical studies are ongoing to support the use of ablative radiation dose to control VT. The aim of the current prospective pilot study is to report the efficacy and tolerability of SABR in ICD implanted pts with refractory VT in our centre. Non-invasive electroanatomical mapping (EAM), cardiac computed tomography (CT), and 18F-fluorodeoxyglucose positron emission (FDG-PET)-CT scan were used and combined with a radiation CT scan. A dose prescription of 25 Gy in a single dose was delivered by volumetric modulated arc therapy (VMAT) Linac-based. The primary endpoint was efficacy, defined as a reduction in ICD shocks after SABR treatment, while the secondary endpoint was safety. Six consecutive pts (five males and one female) implanted with an ICD and with three or more VT were enrolled. One pts died after 1 month, due to end-stage heart failure. Two pts experienced ICD shocks in VT 2 and 5 months after treatment. Three pts experienced no more ICD shocks on VT after therapy. Our data suggest the efficacy and safety of SABR treatment in pts with VT. Larger dataset of pts and longer follow-up are otherwise required to validate the impact of SABR as a standardized treatment in these pts.
Collapse
Affiliation(s)
- Giulio Molon
- Cardiology Department, IRCCS Sacro Cuore Don Calabria Hospital, Negrar, Verona, Italy
| | - Niccolò Giaj-Levra
- Advanced Radiation Oncology Department, IRCCS Sacro Cuore Don Calabria Hospital, Negrar, Verona, Italy
| | - Alessandro Costa
- Cardiology Department, IRCCS Sacro Cuore Don Calabria Hospital, Negrar, Verona, Italy
| | - Stefano Bonapace
- Cardiology Department, IRCCS Sacro Cuore Don Calabria Hospital, Negrar, Verona, Italy
| | - Francesco Cuccia
- Advanced Radiation Oncology Department, IRCCS Sacro Cuore Don Calabria Hospital, Negrar, Verona, Italy
| | - Alessio Marinelli
- Cardiology Department, IRCCS Sacro Cuore Don Calabria Hospital, Negrar, Verona, Italy
| | | | - Gianluisa Sicignano
- Advanced Radiation Oncology Department, IRCCS Sacro Cuore Don Calabria Hospital, Negrar, Verona, Italy
| | - Filippo Alongi
- Advanced Radiation Oncology Department, IRCCS Sacro Cuore Don Calabria Hospital, Negrar, Verona, Italy
- University of Brescia, Brescia, Italy
| |
Collapse
|
27
|
Casula M, Dusi V, Camps S, Gringet J, Benoit T, Garonna A, Rordorf R. Feasibility of an Automatic Ultrasonographic Image Acquisition System Associated With an Artificial Intelligence Algorithm for Real-Time Monitoring of Cardiac Motion During Cardiac Radio-Ablation. Front Cardiovasc Med 2022; 9:849234. [PMID: 35548427 PMCID: PMC9081646 DOI: 10.3389/fcvm.2022.849234] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/05/2022] [Accepted: 03/28/2022] [Indexed: 11/17/2022] Open
Abstract
Background The management of the cardio-respiratory motion of the target and the reduction of the uncertainties related to patient's positioning are two of the main challenges that stereotactic arrhythmia radio-ablation (STAR) has to overcome. A prototype of a system was developed that can automatically acquire and interpret echocardiographic images using an artificial intelligence (AI) algorithm to calculate cardiac displacement in real-time. Methods We conducted a single center study enrolling consecutive patients with a history of ventricular arrhythmias (VA) in order to evaluate the feasibility of this automatic acquisition system. Echocardiographic images were automatically acquired from the parasternal and apical views with a dedicated probe. The system was designed to hold the probe fixed to the chest in the supine position during both free-breathing and short expiratory breath-hold sequences, to simulate STAR treatment. The primary endpoint was the percentage of patients reaching a score ≥2 in a multi-parametric assessment evaluating the quality of automatically acquired images. Moreover, we investigated the potential impact of clinical and demographic characteristics on achieving the primary endpoint. Results We enrolled 24 patients (63 ± 14 years, 21% females). All of them had a history of VA and 21 (88%) had an ICD. Eight patients (33%) had coronary artery disease, 12 (50%) had non-ischemic cardiomyopathy, and 3 had idiopathic VA. Parasternal, as well as apical images were obtained from all patients except from one, in whom parasternal view could not be collected due to the patient's inability to maintain the supine position. The primary endpoint was achieved in 23 patients (96%) for the apical view, in 20 patients (87%) for the parasternal view, and in all patients in at least one of the two views. The images' quality was maximal (i.e., score = 4) in at least one of the two windows in 19 patients (79%). Atrial fibrillation arrhythmia was the only clinical characteristics associated with a poor score outcome in both imaging windows (apical p = 0.022, parasternal p = 0.014). Conclusions These results provide the proof-of-concept for the feasibility of an automatic ultrasonographic image acquisition system associated with an AI algorithm for real-time monitoring of cardiac motion in patients with a history of VA.
Collapse
Affiliation(s)
- Matteo Casula
- Arrhythmia and Electrophysiology Unit, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
- Section of Cardiology, Department of Molecular Medicine, University of Pavia, Pavia, Italy
| | - Veronica Dusi
- Arrhythmia and Electrophysiology Unit, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
- Unit of Cardiology, AOU Città della Salute e della Scienza, Turin, Italy
| | | | | | | | | | - Roberto Rordorf
- Arrhythmia and Electrophysiology Unit, Fondazione IRCCS Policlinico San Matteo, Pavia, Italy
- *Correspondence: Roberto Rordorf
| |
Collapse
|
28
|
Haskova J, Peichl P, Šramko M, Cvek J, Knybel L, Jiravský O, Neuwirth R, Kautzner J. Case Report: Repeated Stereotactic Radiotherapy of Recurrent Ventricular Tachycardia: Reasons, Feasibility, and Safety. Front Cardiovasc Med 2022; 9:845382. [PMID: 35425817 PMCID: PMC9004321 DOI: 10.3389/fcvm.2022.845382] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/29/2021] [Accepted: 02/24/2022] [Indexed: 11/14/2022] Open
Abstract
Stereotactic body radiotherapy (SBRT) has been reported as an attractive option for cases of failed catheter ablation of ventricular tachycardia (VT) in structural heart disease. However, even this strategy can fail for various reasons. For the first time, this case series describes three re-do cases of SBRT which were indicated for three different reasons. The purpose in the first case was the inaccuracy of the determination of the treatment volume by indirect comparison of the electroanatomical map and CT scan. A newly developed strategy of co-registration of both images allowed precise targeting of the substrate. In this case, the second treatment volume overlapped by 60% with the first one. The second reason for the re-do of SBRT was an unusual character of the substrate–large cardiac fibroma associated with different morphologies of VT from two locations around the tumor. The planned treatment volumes did not overlap. The third reason for repeated SBRT was the large intramural substrate in the setting of advanced heart failure. The first treatment volume targeted arrhythmias originating in the basal inferoseptal region, while the second SBRT was focused on adjacent basal septum without significant overlapping. Our observations suggested that SBRT for VT could be safely repeated in case of later arrhythmia recurrences (i.e., after at least 6 weeks). No acute toxicity was observed and in two cases, no side effects were observed during 32 and 22 months, respectively. To avoid re-do SBRT due to inaccurate targeting, the precise and reproducible strategy of substrate identification and co-registration with CT image should be used.
Collapse
Affiliation(s)
- Jana Haskova
- Department of Cardiology, Institute for Clinical and Experimental Medicine (IKEM), Prague, Czechia
- *Correspondence: Jana Haskova
| | - Petr Peichl
- Department of Cardiology, Institute for Clinical and Experimental Medicine (IKEM), Prague, Czechia
| | - Marek Šramko
- Department of Cardiology, Institute for Clinical and Experimental Medicine (IKEM), Prague, Czechia
| | - Jakub Cvek
- Department of Oncology, University Hospital Ostrava, Ostrava, Czechia
- Department of Oncology, Ostrava University Medical School, Ostrava, Czechia
| | - Lukáš Knybel
- Department of Oncology, University Hospital Ostrava, Ostrava, Czechia
| | - Otakar Jiravský
- Department of Cardiology, Podlesí Hospital Trinec, Trinec, Czechia
| | - Radek Neuwirth
- Department of Cardiology, Podlesí Hospital Trinec, Trinec, Czechia
- Department of Cardiology, Masaryk University Medical School, Brno, Czechia
| | - Josef Kautzner
- Department of Cardiology, Institute for Clinical and Experimental Medicine (IKEM), Prague, Czechia
| |
Collapse
|
29
|
Akdag O, Borman PTS, Woodhead P, Uijtewaal P, Mandija S, Van Asselen B, Verhoeff JJC, Raaymakers BW, Fast MF. First experimental exploration of real-time cardiorespiratory motion management for future stereotactic arrhythmia radioablation treatments on the MR-linac. Phys Med Biol 2022; 67. [PMID: 35189610 DOI: 10.1088/1361-6560/ac5717] [Citation(s) in RCA: 17] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/18/2021] [Accepted: 02/21/2022] [Indexed: 12/25/2022]
Abstract
Objective.Stereotactic arrhythmia radioablation (STAR) is a novel, non-invasive treatment for refractory ventricular tachycardia (VT). The VT isthmus is subject to both respiratory and cardiac motion. Rapid cardiac motion presents a unique challenge. In this study, we provide first experimental evidence for real-time cardiorespiratory motion-mitigated MRI-guided STAR on the 1.5 T Unity MR-linac (Elekta AB, Stockholm, Sweden) aimed at simultaneously compensating cardiac and respiratory motions.Approach.A real-time cardiorespiratory motion-mitigated radiotherapy workflow was developed on the Unity MR-linac in research mode. A 15-beam intensity-modulated radiation therapy treatment plan (1 × 25 Gy) was created in Monaco v.5.40.01 (Elekta AB) for the Quasar MRI4Dphantom (ModusQA, London, ON). A film dosimetry insert was moved by combining either artificial (cos4, 70 bpm, 10 mm peak-to-peak) or subject-derived (59 average bpm, 15.3 mm peak-to-peak) cardiac motion with respiratory (sin, 12 bpm, 20 mm peak-to-peak) motion. A balanced 2D cine MRI sequence (13 Hz, field-of-view = 400 × 207 mm2, resolution = 3 × 3 × 15 mm3) was developed to estimate cardiorespiratory motion. Cardiorespiratory motion was estimated by rigid registration and then deconvoluted into cardiac and respiratory components. For beam gating, the cardiac component was used, whereas the respiratory component was used for MLC-tracking. In-silico dose accumulation experiments were performed on three patient data sets to simulate the dosimetric effect of cardiac motion on VT targets.Main results.Experimentally, a duty cycle of 57% was achieved when simultaneously applying respiratory MLC-tracking and cardiac gating. Using film, excellent agreement was observed compared to a static reference delivery, resulting in a 1%/1 mm gamma pass rate of 99%. The end-to-end gating latency was 126 ms on the Unity MR-linac. Simulations showed that cardiac motion decreased the target's D98% dose between 0.1 and 1.3 Gy, with gating providing effective mitigation.Significance.Real-time MRI-guided cardiorespiratory motion management greatly reduces motion-induced dosimetric uncertainty and warrants further research and development for potential future use in STAR.
Collapse
Affiliation(s)
- O Akdag
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - P T S Borman
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - P Woodhead
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.,Elekta AB, Kungstensgatan 18, 113 57 Stockholm, Sweden
| | - P Uijtewaal
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - S Mandija
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands.,Computational Imaging Group for MR Diagnostics and Therapy, Center for Image Sciences, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - B Van Asselen
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - J J C Verhoeff
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - B W Raaymakers
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| | - M F Fast
- Department of Radiotherapy, University Medical Center Utrecht, Heidelberglaan 100, 3584 CX Utrecht, The Netherlands
| |
Collapse
|
30
|
Kashani R, Cao M, Carlson DJ. Radiation Therapy for the Treatment of Cardiac Arrhythmias. Int J Radiat Oncol Biol Phys 2022; 112:577-580. [DOI: 10.1016/j.ijrobp.2021.11.002] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/19/2022]
|
31
|
Bellec J, Rigal L, Hervouin A, Martins R, Lederlin M, Jaksic N, Castelli J, Benali K, de Crevoisier R, Simon A. Cardiac radioablation for ventricular tachycardia: Which approach for incorporating cardiorespiratory motions into the planning target volume? Phys Med 2022; 95:16-24. [DOI: 10.1016/j.ejmp.2022.01.004] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/10/2021] [Revised: 01/10/2022] [Accepted: 01/11/2022] [Indexed: 10/19/2022] Open
|
32
|
Bauer BK, Meier C, Bietenbeck M, Lange PS, Eckardt L, Yilmaz A. Cardiovascular Magnetic Resonance-Guided Radiofrequency Ablation: Where Are We Now? JACC Clin Electrophysiol 2022; 8:261-274. [PMID: 35210090 DOI: 10.1016/j.jacep.2021.11.017] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2021] [Revised: 11/08/2021] [Accepted: 11/17/2021] [Indexed: 11/16/2022]
Abstract
The possibilities of cardiovascular magnetic resonance (CMR) imaging for myocardial tissue characterization and catheter ablation guidance are accompanied by some fictional concepts. In this review, we present the available facts about CMR-guided catheter ablation procedures as well as promising, however unproven, theoretical concepts. CMR promises to visualize the respective arrhythmogenic substrate and may thereby make it more localizable for electrophysiology (EP)-based ablation. Robust CMR imaging is challenged by motion of the heart resulting from cardiac and respiratory cycles. In contrast to conventional "passive" tracking of the catheter tip by real-time CMR, novel approaches based on "active" tracking are performed by integrating microcoils into the catheter tip that send a receiver signal. Several experimental and clinical studies were already performed based on real-time CMR for catheter ablation of atrial and ventricular arrhythmias. Importantly, successful ablation of the cavotricuspid isthmus was already performed in patients with typical atrial flutter. However, a complete EP procedure with real-time CMR-guided transseptal puncture and subsequent pulmonary vein isolation has not been shown so far in patients with atrial fibrillation. Moreover, real-time CMR-guided EP for ventricular tachycardia ablation was only performed in animal models using a transseptal, retrograde, or epicardial access-but not in humans. Essential improvements within the next few years regarding basic technical requirements, such as higher spatial and temporal resolution of real-time CMR imaging as well as clinically approved cardiac magnetic resonance-conditional defibrillators, are ultimately required-but can also be expected-and will move this field forward.
Collapse
Affiliation(s)
- Bastian Klemens Bauer
- Department of Cardiology II - Electrophysiology, University Hospital Münster, Münster, Germany
| | - Claudia Meier
- Department of Cardiology, Division of Cardiovascular Imaging, University Hospital Münster, Münster, Germany
| | - Michael Bietenbeck
- Department of Cardiology, Division of Cardiovascular Imaging, University Hospital Münster, Münster, Germany
| | - Philipp Sebastian Lange
- Department of Cardiology II - Electrophysiology, University Hospital Münster, Münster, Germany
| | - Lars Eckardt
- Department of Cardiology II - Electrophysiology, University Hospital Münster, Münster, Germany
| | - Ali Yilmaz
- Department of Cardiology, Division of Cardiovascular Imaging, University Hospital Münster, Münster, Germany.
| |
Collapse
|
33
|
Siedow M, Brownstein J, Prasad RN, Loccoh E, Harfi TT, Okabe T, Tong MS, Afzal MR, Williams T. Cardiac radioablation in the treatment of ventricular tachycardia. Clin Transl Radiat Oncol 2021; 31:71-79. [PMID: 34646951 PMCID: PMC8498093 DOI: 10.1016/j.ctro.2021.02.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 02/02/2021] [Accepted: 02/08/2021] [Indexed: 11/25/2022] Open
Abstract
Cardiac radioablation with SBRT is a very promising non-invasive modality for the treatment of refractory VT and potentially other cardiac arrhythmias. Initial reports indicate that it is relatively safe and associated with excellent responses, particularly in reduction of ICD-related events, need for anti-arrhythmic medications, and resulting in significantly improved quality of life for patients. Establishment of objective criteria for candidates for cardiac radioablation will accelerate the adoption of this important radiation therapy modality in the treatment of refractory VT and other cardiac arrhythmias in the coming years. In addition, in order to develop more prospective safety and efficacy data, treatment of patients should ideally be performed in the context of clinical trials or prospective registries at, or in collaboration with, experienced centers. Taken together, the future of cardiac radioablation is rich and worthy of further investigation to become a standard treatment in the armamentarium against refractory VT.
Collapse
Affiliation(s)
- Michael Siedow
- Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Jeremy Brownstein
- Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Rahul N. Prasad
- Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Emefah Loccoh
- Department of Radiation Oncology, The Ohio State University Wexner Medical Center, Columbus, OH, USA
| | - Thura T. Harfi
- Division of Cardiovascular Medicine, The Ohio State University Medical Center, Columbus, OH, USA
| | - Toshimasa Okabe
- Division of Cardiovascular Medicine, The Ohio State University Medical Center, Columbus, OH, USA
| | - Matthew S. Tong
- Division of Cardiovascular Medicine, The Ohio State University Medical Center, Columbus, OH, USA
| | - Muhammad R. Afzal
- Division of Cardiovascular Medicine, The Ohio State University Medical Center, Columbus, OH, USA
| | - Terence Williams
- Department of Radiation Oncology, City of Hope National Medical Center, Duarte, CA, USA
| |
Collapse
|
34
|
Chalkia M, Kouloulias V, Tousoulis D, Deftereos S, Tsiachris D, Vrachatis D, Platoni K. Stereotactic Arrhythmia Radioablation as a Novel Treatment Approach for Cardiac Arrhythmias: Facts and Limitations. Biomedicines 2021; 9:biomedicines9101461. [PMID: 34680578 PMCID: PMC8533522 DOI: 10.3390/biomedicines9101461] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2021] [Revised: 09/29/2021] [Accepted: 10/11/2021] [Indexed: 11/24/2022] Open
Abstract
Stereotactic ablative radiotherapy (SABR) is highly focused radiation therapy that targets well-demarcated, limited-volume malignant or benign tumors with high accuracy and precision using image guidance. Stereotactic arrhythmia radioablation (STAR) applies SABR to treat cardiac arrhythmias, including ventricular tachycardia (VT) and atrial fibrillation (AF), and has recently been a focus in research. Clinical studies have demonstrated electrophysiologic conduction blockade and histologic fibrosis after STAR, which provides a proof of principle for its potential for treating arrhythmias. This review will present the basic STAR principles, available clinical study outcomes, and how the technique has evolved since the first pre-clinical study. In addition to the clinical workflow, focus will be given on the process for stereotactic radiotherapy Quality Assurance (QA) tests, as well as the need for establishing a standardized QA protocol. Future implications and potential courses of research will also be discussed.
Collapse
Affiliation(s)
- Marina Chalkia
- Radiotherapy Unit, Second Department of Radiology, School of Medicine, Rimini 1, National and Kapodistrian University of Athens, 124 62 Athens, Greece; (V.K.); (K.P.)
- Correspondence: ; Tel.: +30-2105326418
| | - Vassilis Kouloulias
- Radiotherapy Unit, Second Department of Radiology, School of Medicine, Rimini 1, National and Kapodistrian University of Athens, 124 62 Athens, Greece; (V.K.); (K.P.)
| | - Dimitris Tousoulis
- First Department of Cardiology, ‘Hippokration’ General Hospital, Vasilissis Sofias 114, 115 27 Athens, Greece;
| | - Spyridon Deftereos
- Second Department of Cardiology, “Attikon” University Hospital, School of Medicine, Rimini 1, National and Kapodistrian University of Athens, 124 62 Athens, Greece; (S.D.); (D.V.)
| | | | - Dimitrios Vrachatis
- Second Department of Cardiology, “Attikon” University Hospital, School of Medicine, Rimini 1, National and Kapodistrian University of Athens, 124 62 Athens, Greece; (S.D.); (D.V.)
| | - Kalliopi Platoni
- Radiotherapy Unit, Second Department of Radiology, School of Medicine, Rimini 1, National and Kapodistrian University of Athens, 124 62 Athens, Greece; (V.K.); (K.P.)
| |
Collapse
|
35
|
Lydiard S, Pontré B, Hindley N, Lowe BS, Sasso G, Keall P. MRI-guided cardiac-induced target motion tracking for atrial fibrillation cardiac radioablation. Radiother Oncol 2021; 164:138-145. [PMID: 34597739 DOI: 10.1016/j.radonc.2021.09.025] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/03/2021] [Revised: 09/13/2021] [Accepted: 09/22/2021] [Indexed: 10/20/2022]
Abstract
BACKGROUND AND PURPOSE Atrial fibrillation (AF) cardiac radioablation (CR) challenges radiotherapy tracking: multiple small targets close to organs-at-risk undergo rapid differential cardiac contraction and respiratory motion. MR-guidance offers a real-time target tracking solution. This work develops and investigates MRI-guided tracking of AF CR targets with cardiac-induced motion. MATERIALS AND METHODS A direct tracking method (Trackingdirect) and two indirect tracking methods leveraging population-based surrogacy relationships with the left atria (Trackingindirect_LA) or other target (Trackingindirect_target) were developed. Tracking performance was evaluated using transverse ECG-gated breathhold MRI images from 15 healthy and 10 AF participants. Geometric and volumetric tracking errors were calculated, defined as the difference between the ground-truth and tracked target centroids and volumes respectively. Transverse, breath-hold, noncardiac-gated cine images were acquired at 4 Hz in 5 healthy and 5 AF participants to qualitatively characterize tracking performance on images more comparable to MRILinac acquisitions. RESULTS The average 3D geometric tracking errors for Trackingdirect, Trackingindirect_LA and Trackingindirect_target respectively were 1.7 ± 1.2 mm, 1.6 ± 1.1 mm and 1.9 ± 1.3 mm in healthy participants and 1.7 ± 1.3 mm, 1.5 ± 1.0 mm and 1.7 ± 1.2 mm in AF participants. For Trackingdirect, 88% of analyzed images had 3D geometric tracking errors <3 mm and the average volume tracking error was 1.7 ± 1.3 cc. For Trackingdirect on non-cardiac-gated cine images, tracked targets overlapped organsat-risk or completely missed the target area on 2.2% and 0.08% of the images respectively. CONCLUSION The feasibility of non-invasive MRI-guided tracking of cardiac-induced AF CR target motion was demonstrated for the first time, showing potential for improving AF CR treatment efficacy.
Collapse
Affiliation(s)
- Suzanne Lydiard
- ACRF Image X Institute, University of Sydney, Eveleigh, Australia.
| | - Beau Pontré
- Department of Anatomy and Medical Imaging, University of Auckland, New Zealand
| | - Nicholas Hindley
- ACRF Image X Institute, University of Sydney, Eveleigh, Australia
| | - Boris S Lowe
- Green Lane Cardiovascular Service, Auckland City Hospital, New Zealand
| | - Giuseppe Sasso
- Department of Anatomy and Medical Imaging, University of Auckland, New Zealand; Radiation Oncology Department, Auckland City Hospital, New Zealand; Department of Oncology, University of Auckland, New Zealand
| | - Paul Keall
- ACRF Image X Institute, University of Sydney, Eveleigh, Australia
| |
Collapse
|
36
|
Wei C, Qian PC, Boeck M, Bredfeldt JS, Blankstein R, Tedrow UB, Mak R, Zei PC. Cardiac stereotactic body radiation therapy for ventricular tachycardia: Current experience and technical gaps. J Cardiovasc Electrophysiol 2021; 32:2901-2914. [PMID: 34587335 DOI: 10.1111/jce.15259] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 06/11/2021] [Revised: 08/20/2021] [Accepted: 09/06/2021] [Indexed: 11/26/2022]
Abstract
INTRODUCTION Despite advances in drug and catheter ablation therapy, long-term recurrence rates for ventricular tachycardia remain suboptimal. Cardiac stereotactic body radiotherapy (SBRT) is a novel treatment that has demonstrated reduction of arrhythmia episodes and favorable short-term safety profile in treatment-refractory patients. Nevertheless, the current clinical experience is early and limited. Recent studies have highlighted variable duration of treatment effect and substantial recurrence rates several months postradiation. Contributing to these differential outcomes are disparate approaches groups have taken in planning and delivering radiation, owing to both technical and knowledge gaps limiting optimization and standardization of cardiac SBRT. METHODS AND FINDINGS In this report, we review the historical basis for cardiac SBRT and existing clinical data. We then elucidate the current technical gaps in cardiac radioablation, incorporating the current clinical experience, and summarize the ongoing and needed efforts to resolve them. CONCLUSION Cardiac SBRT is an emerging therapy that holds promise for the treatment of ventricular tachycardia. Technical gaps remain, to be addressed by ongoing research and growing clincial experience.
Collapse
Affiliation(s)
- Chen Wei
- Harvard Medical School, Boston, Massachusetts, USA.,Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts, USA
| | - Pierre C Qian
- Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts, USA
| | - Michelle Boeck
- Harvard Medical School, Boston, Massachusetts, USA.,Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts, USA.,Department of Radiation Oncology, Brigham and Women's Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts, USA
| | - Jeremy S Bredfeldt
- Harvard Medical School, Boston, Massachusetts, USA.,Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts, USA.,Department of Radiation Oncology, Brigham and Women's Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts, USA
| | - Ron Blankstein
- Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts, USA
| | - Usha B Tedrow
- Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts, USA
| | - Raymond Mak
- Department of Radiation Oncology, Brigham and Women's Hospital/Dana-Farber Cancer Institute, Boston, Massachusetts, USA
| | - Paul C Zei
- Division of Cardiovascular Medicine, Department of Medicine, Brigham and Women's Hospital, Boston, Massachusetts, USA
| |
Collapse
|
37
|
Yang B, Yuan J, Cheung KY, Huang CY, Poon DMC, Yu SK. Magnetic Resonance-Guided Radiation Therapy of Patients With Cardiovascular Implantable Electronic Device on a 1.5 T Magnetic Resonance-Linac. Pract Radiat Oncol 2021; 12:e56-e61. [PMID: 34520872 DOI: 10.1016/j.prro.2021.08.011] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2021] [Revised: 08/28/2021] [Accepted: 08/31/2021] [Indexed: 11/17/2022]
Abstract
Magnetic resonance-guided radiation therapy is reported for treating patients with an insertable cardiac monitor and implantable cardiac pacemakers. All treatments were delivered using a 1.5 T MR-Linac. Among the 4 patients, 2 were treated with stereotactic body radiation therapy at a dose of 40 Gy in 5 fractions. A clinical safety protocol was developed to address the decision-making and patient selection, as well as the clarified responsibilities of different parties for management of patients with cardiovascular implantable electronic devices. Dose estimation based on out-of-field dose data are necessary for cardiovascular implantable electronic devices located outside the treatment fields.
Collapse
Affiliation(s)
- Bin Yang
- Medical Physics and Research Department, Happy Valley, Hong Kong, China.
| | - Jing Yuan
- Medical Physics and Research Department, Happy Valley, Hong Kong, China
| | - Kin Yin Cheung
- Medical Physics and Research Department, Happy Valley, Hong Kong, China
| | - Chen-Yu Huang
- Medical Physics and Research Department, Happy Valley, Hong Kong, China
| | - Darren M C Poon
- Comprehensive Oncology Centre, Hong Kong Sanatorium & Hospital, Happy Valley, Hong Kong, China
| | - Siu Ki Yu
- Medical Physics and Research Department, Happy Valley, Hong Kong, China
| |
Collapse
|
38
|
Hindley N, Lydiard S, Shieh CC, Keall P. Proof-of-concept for x-ray based real-time image guidance during cardiac radioablation. Phys Med Biol 2021; 66. [PMID: 34315136 DOI: 10.1088/1361-6560/ac1834] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2021] [Accepted: 07/27/2021] [Indexed: 11/11/2022]
Abstract
Cardiac radioablation offers non-invasive treatments for refractory arrhythmias. However, treatment delivery for this technique remains challenging. In this paper, we introduce the first method for real-time image guidance during cardiac radioablation for refractory atrial fibrillation on a standard linear accelerator. Our proposed method utilizes direct diaphragm tracking on intrafraction images to estimate the respiratory component of cardiac substructure motion. We compare this method to treatment scenarios without real-time image guidance using the 4D-XCAT digital phantom. Pre-treatment and intrafraction imaging was simulated for 8 phantoms with unique anatomies programmed using cardiorespiratory motion from healthy volunteers. As every voxel in the 4D-XCAT phantom is labelled precisely according to the corresponding anatomical structure, this provided ground-truth for quantitative evaluation. Tracking performance was compared to the ground-truth for simulations with and without real-time image guidance using the left atrium as an exemplar target. Differences in target volume size, mean volumetric coverage, minimum volumetric coverage and geometric error were recorded for each simulation. We observed that differences in target volume size were statistically significant (p < 0.001) across treatment scenarios and that real-time image guidance enabled reductions in target volume size ranging from 11% to 24%. Differences in mean and minimum volumetric coverage were statistically insignificant (bothp = 0.35) while differences in geometric error were statistically significant (p = 0.039). The results of this study provide proof-of-concept for x-ray based real-time image guidance during cardiac radioablation.
Collapse
Affiliation(s)
| | - Suzanne Lydiard
- ACRF Image X Institute, University of Sydney, Sydney, Australia.,Ingham Institute for Applied Medical Research, Liverpool, Australia
| | - Chun-Chien Shieh
- ACRF Image X Institute, University of Sydney, Sydney, Australia.,Sydney Neuroimaging Analysis Centre, University of Sydney, Sydney, Australia
| | - Paul Keall
- ACRF Image X Institute, University of Sydney, Sydney, Australia
| |
Collapse
|
39
|
Krug D, Blanck O, Andratschke N, Guckenberger M, Jumeau R, Mehrhof F, Boda-Heggemann J, Seidensaal K, Dunst J, Pruvot E, Scholz E, Saguner AM, Rudic B, Boldt LH, Bonnemeier H. Recommendations regarding cardiac stereotactic body radiotherapy for treatment refractory ventricular tachycardia. Heart Rhythm 2021; 18:2137-2145. [PMID: 34380072 DOI: 10.1016/j.hrthm.2021.08.004] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 04/06/2021] [Revised: 08/02/2021] [Accepted: 08/03/2021] [Indexed: 11/25/2022]
Abstract
BACKGROUND Ventricular tachycardia (VT) is a potentially lethal complication of structural heart disease. Despite optimal management, a subgroup of patients continue to suffer from recurrent VT. Recently, cardiac stereotactic body radiotherapy (CSBRT) has been introduced as a treatment option in patients with VT refractory to antiarrhythmic drugs and catheter ablation. OBJECTIVE The purpose of this study was to establish an expert consensus regarding the conduct and use of CSBRT for refractory VT. METHODS We conducted a modified Delphi process. Thirteen experts from institutions from Germany and Switzerland participated in the modified Delphi process. Statements regarding the following topics were generated: treatment setting, institutional expertise and technical requirements, patient selection, target volume definition, and monitoring during and after CSBRT. Agreement was rated on a 5-point Likert scale. Cutoffs for agreement were defined in analogy to the RAND methodology. RESULTS There was strong agreement regarding the experimental status of the procedure and the preference for treatment in clinical trials. CSBRT should be conducted at specialized centers with a strong expertise in the management of patients with ventricular arrhythmias and in stereotactic body radiotherapy for moving targets. CSBRT should be restricted to patients with refractory VT with optimal antiarrhythmic medication who underwent prior catheter ablation or have contraindications. Target volume delineation for CSBRT is complex. Therefore, interdisciplinary processes that should include cardiology/electrophysiology and radiation oncology as well as medical physics, radiology, and nuclear medicine are needed. Optimal follow-up is required. CONCLUSION Prospective trials and pooled registries are needed to gain further insight into this promising treatment option for patients with refractory VT.
Collapse
Affiliation(s)
- David Krug
- Department of Radiation Oncology, University Hospital Schleswig-Holstein, Kiel, Germany.
| | - Oliver Blanck
- Department of Radiation Oncology, University Hospital Schleswig-Holstein, Kiel, Germany
| | - Nicolaus Andratschke
- Department of Radiation Oncology, University Hospital Zurich, Zurich, Switzerland
| | | | - Raphael Jumeau
- Department of Radiation Oncology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland; Radiation Oncology Institute, Hirslanden Clinique Bois-Cerf, Lausanne, Switzerland
| | - Felix Mehrhof
- Department of Radiation Oncology, Charité Universitätsmedizin Berlin, Berlin, Germany
| | - Judit Boda-Heggemann
- Department of Radiation Oncology, University Medical Center Mannheim, University of Heidelberg, Medical Faculty Mannheim, Mannheim, Germany
| | - Katharina Seidensaal
- Department of Radiation Oncology, University Hospital Heidelberg, Heidelberg, Germany
| | - Jürgen Dunst
- Department of Radiation Oncology, University Hospital Schleswig-Holstein, Kiel, Germany
| | - Etienne Pruvot
- Heart and Vessel Department, Service of Cardiology, Lausanne University Hospital and University of Lausanne, Lausanne, Switzerland
| | - Eberhard Scholz
- Department of Cardiology, Heidelberg Center for Heart Rhythm Disorders (HCR), University of Heidelberg, Heidelberg, Germany
| | - Ardan M Saguner
- Department of Cardiology, University Heart Center Zurich, Zurich, Switzerland
| | - Boris Rudic
- Department of Internal Medicine I, Section for Electrophysiology und Rhythmology, University Medical Center Mannheim, University of Heidelberg, Medical Faculty Mannheim, Mannheim, Germany
| | - Leif-Hendrik Boldt
- Department of Internal Medicine and Cardiology, Charité University Medicine Berlin-Campus Virchow Klinikum, Berlin, Germany
| | - Hendrik Bonnemeier
- Department of Internal Medicine III, Section for Electrophysiology und Rhythmology, University Hospital Schleswig-Holstein, Kiel, Germany
| |
Collapse
|
40
|
Boda-Heggemann J, Blanck O, Mehrhof F, Ernst F, Buergy D, Fleckenstein J, Tülümen E, Krug D, Siebert FA, Zaman A, Kluge AK, Parwani AS, Andratschke N, Mayinger MC, Ehrbar S, Saguner AM, Celik E, Baus WW, Stauber A, Vogel L, Schweikard A, Budach V, Dunst J, Boldt LH, Bonnemeier H, Rudic B. Interdisciplinary Clinical Target Volume Generation for Cardiac Radioablation: Multicenter Benchmarking for the RAdiosurgery for VENtricular TAchycardia (RAVENTA) Trial. Int J Radiat Oncol Biol Phys 2021; 110:745-756. [DOI: 10.1016/j.ijrobp.2021.01.028] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2020] [Revised: 01/19/2021] [Accepted: 01/21/2021] [Indexed: 02/05/2023]
|
41
|
Gerard IJ, Bernier M, Hijal T, Kopek N, Pater P, Stosky J, Stroian G, Toscani B, Alfieri J. Stereotactic Arrhythmia Radioablation for Ventricular Tachycardia: Single Center First Experiences. Adv Radiat Oncol 2021; 6:100702. [PMID: 34095614 PMCID: PMC8165547 DOI: 10.1016/j.adro.2021.100702] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/09/2020] [Revised: 03/14/2021] [Accepted: 03/31/2021] [Indexed: 12/25/2022] Open
Affiliation(s)
- Ian J Gerard
- Division of Radiation Oncology, McGill University Health Centre, Montreal, Quebec, Canada
| | - Martin Bernier
- Division of Cardiology, McGill University Health Centre, Montreal, Quebec, Canada
| | - Tarek Hijal
- Division of Radiation Oncology, McGill University Health Centre, Montreal, Quebec, Canada
| | - Neil Kopek
- Division of Radiation Oncology, McGill University Health Centre, Montreal, Quebec, Canada
| | - Piotr Pater
- Medical Physics, McGill University Health Centre, Montreal, Quebec, Canada
| | - Jordan Stosky
- Division of Radiation Oncology, University of Calgary, Calgary, Alberta, Canada
| | - Gabriela Stroian
- Medical Physics, McGill University Health Centre, Montreal, Quebec, Canada
| | - Bruno Toscani
- Division of Cardiology, McGill University Health Centre, Montreal, Quebec, Canada
| | - Joanne Alfieri
- Division of Radiation Oncology, McGill University Health Centre, Montreal, Quebec, Canada
| |
Collapse
|
42
|
Ren XY, He PK, Gao XS, Zhao ZL, Zhao B, Bai Y, Liu SW, Li K, Qin SB, Ma MW, Zhou J, Rong Y. Dosimetric feasibility of stereotactic ablative radiotherapy in pulmonary vein isolation for atrial fibrillation using intensity-modulated proton therapy. J Appl Clin Med Phys 2021; 22:79-88. [PMID: 33817981 PMCID: PMC8130224 DOI: 10.1002/acm2.13239] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/11/2020] [Revised: 03/03/2021] [Accepted: 03/06/2021] [Indexed: 12/25/2022] Open
Abstract
Purpose To evaluate dosimetric properties of intensity‐modulated proton therapy (IMPT) for simulated treatment planning in patients with atrial fibrillation (AF) targeting left atrial‐pulmonary vein junction (LA‐PVJ), in comparison with volumetric‐modulated arc therapy (VMAT) and helical tomotherapy (TOMO). Methods Ten thoracic 4D‐CT scans with respiratory motion and one with cardiac motion were used for the study. Ten respiratory 4D‐CTs were planned with VMAT, TOMO, and IMPT for simulated AF. Targets at the LA‐PVJ were defined as wide‐area circumferential ablation line. A single fraction of 25 Gy was prescribed to all plans. The interplay effects from cardiac motion were evaluated based on the cardiac 4D‐CT scan. Dose‐volume histograms (DVHs) of the ITV and normal tissues were compared. Statistical analysis was evaluated via one‐way Repeated‐Measures ANOVA and Friedman’s test with Bonferroni’s multiple comparisons test. Results The median volume of ITV was 8.72cc. All plans had adequate target coverage (V23.75Gy ≥ 99%). Compared with VMAT and TOMO, IMPT resulted in significantly lower dose of most normal tissues. For VMAT, TOMO, and IMPT plans, Dmean of the whole heart was 5.52 ± 0.90 Gy, 5.89 ± 0.78 Gy, and 3.01 ± 0.57 Gy (P < 0.001), mean dose of pericardium was 4.74 ± 0.76 Gy, 4.98 ± 0.62 Gy, and 2.59 ± 0.44 Gy (P < 0.001), and D0.03cc of left circumflex artery (LCX) was 13.96 ± 5.45 Gy, 14.34 ± 5.91 Gy, and 8.43 ± 7.24 Gy (P < 0.001), respectively. However, no significant advantage for one technique over the others was observed when examining the D0.03cc of esophagus and main bronchi. Conclusions IMPT targeting LA‐PVJ for patients with AF has high potential to reduce dose to surrounding tissues compared to VMAT or TOMO. Motion mitigation techniques are critical for a particle‐therapy approach.
Collapse
Affiliation(s)
- Xue-Ying Ren
- Department of Radiation Oncology, Peking University First Hospital, Beijing, China
| | - Peng-Kang He
- Department of Cardiology, Peking University First Hospital, Beijing, China
| | - Xian-Shu Gao
- Department of Radiation Oncology, Peking University First Hospital, Beijing, China
| | - Zhi-Lei Zhao
- Department of Radiation Oncology, Yizhou International Proton Therapy Medical Center, Hebei, China
| | - Bo Zhao
- Department of Radiation Oncology, Peking University First Hospital, Beijing, China
| | - Yun Bai
- Department of Radiation Oncology, Peking University First Hospital, Beijing, China
| | - Si-Wei Liu
- Department of Radiation Oncology, Peking University First Hospital, Beijing, China
| | - Kang Li
- Department of Cardiology, Peking University First Hospital, Beijing, China
| | - Shang-Bin Qin
- Department of Radiation Oncology, Peking University First Hospital, Beijing, China
| | - Ming-Wei Ma
- Department of Radiation Oncology, Peking University First Hospital, Beijing, China
| | - Jing Zhou
- Department of Cardiology, Peking University First Hospital, Beijing, China
| | - Yi Rong
- Department of Radiation Oncology, Mayo Clinic Arizona, Phoenix, AZ, USA
| |
Collapse
|
43
|
Corradini S, von Bestenbostel R, Romano A, Curta A, Di Gioia D, Placidi L, Niyazi M, Boldrini L. MR-guided stereotactic body radiation therapy for primary cardiac sarcomas. Radiat Oncol 2021; 16:60. [PMID: 33771179 PMCID: PMC7995725 DOI: 10.1186/s13014-021-01791-9] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/18/2021] [Accepted: 03/17/2021] [Indexed: 03/10/2023] Open
Abstract
BACKGROUND Primary cardiac tumors are an extremely rare disease with limited prognosis. The treatment of choice is surgery. Other treatment options include chemotherapy and radiation therapy, which historically represented a palliative approach in patients who were not eligible for surgery. The development of hybrid MR-guided radiation therapy makes it possible to better visualize cardiac lesions and to apply high doses per fraction in sensible organs such as the heart. CASE PRESENTATION Patients affected by inoperable primary cardiac sarcomas and treated at two different institutions were considered for this analysis and retrospectively analyzed. All patients were treated using a 0.35 T hybrid MR Linac system (MRIdian, ViewRay Inc., Mountain View, CA). In the present study we investigated the feasibility, early outcome and toxicity of MR-guided RT in primary cardiac sarcomas. Four consecutive non-metastasized patients who were treated between 05-09/2020 were analyzed. The cardiac sarcomas were mostly located in the right atrium (50%) and one patient presented with 3 epicardial lesions. All patients received MRgRT as a salvage treatment for recurrent cardiac sarcoma after initial surgery, after a mean interval of 12 months (range 1-29 months). Regarding the treatment characteristics, the mean GTV size was 22.9 cc (range 2.5-56.9 cc) and patients were treated with a mean GTV dose of 38.9 Gy (range 30.1-41.1 Gy) in 5 fractions. Regarding feasibility, all treatments were completed as planned and all patients tolerated the treatment very well and showed only mild grade 1 or 2 symptoms like fatigue, dyspnea or mild chest pain at early follow-up. CONCLUSION To the best of our knowledge, in this retrospective analysis we present the first and largest series of patients presenting with primary cardiac sarcomas treated with online adaptive MRgRT. However, further studies are needed to evaluate the impact of this new methodology on the outcome of this very rare disease.
Collapse
Affiliation(s)
- Stefanie Corradini
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | | | - Angela Romano
- Department of Bioimaging, Radiation Oncology and Hematology, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy.
| | - Adrian Curta
- Department of Radiology, University Hospital, LMU Munich, Munich, Germany
| | - Dorit Di Gioia
- Department of Medicine III, University Hospital, LMU Munich, Munich, Germany
| | - Lorenzo Placidi
- Department of Bioimaging, Radiation Oncology and Hematology, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
| | - Maximilian Niyazi
- Department of Radiation Oncology, University Hospital, LMU Munich, Munich, Germany
| | - Luca Boldrini
- Department of Bioimaging, Radiation Oncology and Hematology, Fondazione Policlinico Universitario "A. Gemelli" IRCCS, Rome, Italy
| |
Collapse
|
44
|
Miszczyk M, Jadczyk T, Gołba K, Wojakowski W, Wita K, Bednarek J, Blamek S. Clinical Evidence behind Stereotactic Radiotherapy for the Treatment of Ventricular Tachycardia (STAR)-A Comprehensive Review. J Clin Med 2021; 10:jcm10061238. [PMID: 33802802 PMCID: PMC8002399 DOI: 10.3390/jcm10061238] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/18/2021] [Revised: 03/14/2021] [Accepted: 03/15/2021] [Indexed: 12/31/2022] Open
Abstract
The electrophysiology-guided noninvasive cardiac radioablation, also known as STAR (stereotactic arrhythmia radioablation) is an emerging treatment method for persistent ventricular tachycardia. Since its first application in 2012 in Stanford Cancer Institute, and a year later in University Hospital Ostrava, Czech Republic, the authors from all around the world have published case reports and case series, and several prospective trials were established. In this article, we would like to discuss the available clinical evidence, analyze the potentially clinically relevant differences in methodology, and address some of the unique challenges that come with this treatment method.
Collapse
Affiliation(s)
- Marcin Miszczyk
- IIIrd Department of Radiotherapy and Chemotherapy, Maria Sklodowska-Curie National Research Institute of Oncology, 44-102 Gliwice, Poland
- Correspondence: ; Tel.: +48-663-040-809
| | - Tomasz Jadczyk
- Department of Cardiology and Structural Heart Diseases, Medical University of Silesia, 40-055 Katowice, Poland; (T.J.); (W.W.)
- International Clinical Research Center, Interventional Cardiac Electrophysiology Group, St. Anne’s University Hospital Brno, 664/53 Brno, Czech Republic
| | - Krzysztof Gołba
- Upper-Silesian Heart Center, Department of Electrocardiology, 40-055 Katowice, Poland;
- Department of Electrocardiology and Heart Failure, Medical University of Silesia, 40-055 Katowice, Poland
| | - Wojciech Wojakowski
- Department of Cardiology and Structural Heart Diseases, Medical University of Silesia, 40-055 Katowice, Poland; (T.J.); (W.W.)
| | - Krystian Wita
- First Department of Cardiology, Medical University of Silesia, 40-055 Katowice, Poland;
| | - Jacek Bednarek
- Department of Electrocardiology, John Paul II Hospital, 31-202 Cracow, Poland;
| | - Sławomir Blamek
- Department of Radiotherapy, Maria Sklodowska-Curie National Research Institute of Oncology, 44-102 Gliwice, Poland;
| |
Collapse
|
45
|
Lydiard, PGDip S, Blanck O, Hugo G, O’Brien R, Keall P. A Review of Cardiac Radioablation (CR) for Arrhythmias: Procedures, Technology, and Future Opportunities. Int J Radiat Oncol Biol Phys 2021; 109:783-800. [DOI: 10.1016/j.ijrobp.2020.10.036] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 10/22/2020] [Accepted: 10/27/2020] [Indexed: 10/23/2022]
|
46
|
Munshi A. Ablative radiosurgery for cardiac arrhythmias - A systematic review. Cancer Radiother 2021; 25:373-379. [PMID: 33589330 DOI: 10.1016/j.canrad.2021.01.009] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/03/2020] [Revised: 01/21/2021] [Accepted: 01/21/2021] [Indexed: 10/22/2022]
Abstract
Stereotactic body radiotherapy (SBRT) is a high precision technique that is commonly used for malignant lesions in lung, liver, pancreas and spine. Recent reports suggest promise in use of SBRT as a tool in atrial and ventricular cardiac arrhythmias. The present systematic review deals with the use of SBRT technology for this novel indication. A PubMed search was done for articles published between 1990 and 2020. All original articles, case reports, case series of treated patients were included in the analyses. Out of the 55 articles in PubMed search, our search found 1 phase I/II clinical case series, 3 clinical case reports, 3 animal studies and 4 dosimetric studies related to cardiac SBRT for arrythmias. All studies used a uniform cardiac dose of 25Gy. The available preclinical, dosimetric and clinical studies have suggested that SBRT for cardiac arrhythmias could become a potential alternative in suitable patients. Cardiac and radiation oncology community await further data and experience in this modality, including safety and outcomes.
Collapse
Affiliation(s)
- A Munshi
- Department of Radiation Oncology, Manipal Hospitals, Dwarka, New Delhi, India.
| |
Collapse
|
47
|
Narducci ML, Cellini F, Placidi L, Boldrini L, Perna F, Bencardino G, Pinnacchio G, Bertolini R, Cannelli G, Frascino V, Tagliaferri L, Chiesa S, Mattiucci GC, Balducci M, Gambacorta MA, Rossi M, Indovina L, Pelargonio G, Valentini V, Crea F. Case Report: A Case Report of Stereotactic Ventricular Arrhythmia Radioablation (STAR) on Large Cardiac Target Volume by Highly Personalized Inter- and Intra-fractional Image Guidance. Front Cardiovasc Med 2020; 7:565471. [PMID: 33330640 PMCID: PMC7719630 DOI: 10.3389/fcvm.2020.565471] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2020] [Accepted: 09/25/2020] [Indexed: 12/31/2022] Open
Abstract
Introduction: Although catheter ablation is the current gold standard treatment for refractory ventricular arrhythmias, sometimes its efficacy is not optimal and it's associated with high risks of procedural complication and death. Stereotactic arrhythmia radioablation (STAR) is increasingly being adopted for such clinical presentation, considering its efficacy and safety.Case Presentation: We do report our experience managing a case of high volume of left ventricle for refractory ventricular tachycardia in advanced heart failure patient, by delivering a single fraction of STAR through an highly personalization of dose delivery applying repeated inter- and continuous intra-fraction image guidance.Conclusion: According to the literature reports, we recommend considering increasing as much as possible the personalization features and safety technical procedure as long as that is not significantly affecting the STAR duration. Moreover, the duration in itself shouldn't be the main parameter, but balanced into the frame of possibly obtainable outcome improvement. At best of our knowledge, this is the first report applying such specific technology onto this clinical setting. Future studies will clarify these issues.
Collapse
Affiliation(s)
- Maria Lucia Narducci
- Dipartimento di Scienze Cardiovascolari, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Francesco Cellini
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, UOC di Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Lorenzo Placidi
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, UOC di Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Luca Boldrini
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, UOC di Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Francesco Perna
- Dipartimento di Scienze Cardiovascolari, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Gianluigi Bencardino
- Dipartimento di Scienze Cardiovascolari, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Gaetano Pinnacchio
- Dipartimento di Scienze Cardiovascolari, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Roberta Bertolini
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Giorgio Cannelli
- Department of Anesthesiology, Intensive Care and Pain Therapy, Fondazione Policlinico A. Gemelli IRCCS, Catholic University of the Sacred Heart, Rome, Italy
| | - Vincenzo Frascino
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, UOC di Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Luca Tagliaferri
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, UOC di Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Silvia Chiesa
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, UOC di Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Gian Carlo Mattiucci
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, UOC di Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Mario Balducci
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, UOC di Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Maria Antonietta Gambacorta
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, UOC di Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Marco Rossi
- Department of Anesthesiology, Intensive Care and Pain Therapy, Fondazione Policlinico A. Gemelli IRCCS, Catholic University of the Sacred Heart, Rome, Italy
| | - Luca Indovina
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, UOC di Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
| | - Gemma Pelargonio
- Dipartimento di Scienze Cardiovascolari, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
- Istituto di Cardiologia, Università Cattolica del Sacro Cuore, Rome, Italy
- *Correspondence: Gemma Pelargonio
| | - Vincenzo Valentini
- Dipartimento di Diagnostica per Immagini, Radioterapia Oncologica ed Ematologia, UOC di Radioterapia Oncologica, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
- Istituto di Radiologia, Università Cattolica del Sacro Cuore, Rome, Italy
| | - Filippo Crea
- Dipartimento di Scienze Cardiovascolari, Fondazione Policlinico Universitario A. Gemelli IRCCS, Rome, Italy
- Istituto di Cardiologia, Università Cattolica del Sacro Cuore, Rome, Italy
| |
Collapse
|
48
|
Jumeau R, Pruvot É, Thariat J, Latorzeff I, Milliez PU, Champ-Rigot L, De Crevoisier R, Ferchaud V. Tachycardies ventriculaires réfractaires : quelle place pour la radiothérapie et comment ? Cancer Radiother 2020; 24:534-546. [DOI: 10.1016/j.canrad.2020.06.005] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/22/2020] [Accepted: 06/07/2020] [Indexed: 12/31/2022]
|
49
|
Widesott L, Dionisi F, Fracchiolla F, Tommasino F, Centonze M, Amichetti M, Del Greco M. Proton or photon radiosurgery for cardiac ablation of ventricular tachycardia? Breath and ECG gated robust optimization. Phys Med 2020; 78:15-31. [PMID: 32911373 DOI: 10.1016/j.ejmp.2020.08.021] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 02/17/2020] [Revised: 07/20/2020] [Accepted: 08/24/2020] [Indexed: 10/23/2022] Open
Abstract
PURPOSE Ventricular tachycardia (VT) is a life-threatening heart disorder. The aim of this preliminary study is to assess the feasibility of stereotactic body radiation therapy (SBRT) photon and proton therapy (PT) plans for the treatment of VT, adopting robust optimization technique for both irradiation techniques. METHODS ECG gated CT images (in breath hold) were acquired for one patient. Conventional planning target volume (PTV) and robust optimized plans (25GyE in single fraction) were simulated for both photon (IMRT, 5 and 9 beams) and proton (SFO, 2 beams) plans. Robust optimized plans were obtained both for protons and photons considering in the optimization setup errors (5 mm in the three orthogonal directions), range (±3.5%) and the clinical target volume (CTV) motion due to heartbeat and breath-hold variability. RESULTS The photon robust optimization method, compared to PTV-based plans, showed a reduction in the average dose to the heart by about 25%; robust optimization allowed also reducing the mean dose to the left lung from 3.4. to 2.8 Gy for 9-beams configuration and from 4.1 to 2.9 Gy for 5-beams configuration. Robust optimization with protons, allowed further reducing the OAR doses: average dose to the heart and to the left lung decreased from 7.3 Gy to 5.2 GyE and from 2.9 Gy to 2.2 GyE, respectively. CONCLUSIONS Our study demonstrates the importance of the optimization technique adopted in the treatment planning system for VT treatment. It has been shown that robust optimization can significantly reduce the dose to healthy cardiac tissues and that PT further increases this gain.
Collapse
Affiliation(s)
- Lamberto Widesott
- Proton Therapy Department, Azienda Provinciale per i Servizi Sanitari (APSS), Trento, Italy.
| | - Francesco Dionisi
- Proton Therapy Department, Azienda Provinciale per i Servizi Sanitari (APSS), Trento, Italy
| | - Francesco Fracchiolla
- Proton Therapy Department, Azienda Provinciale per i Servizi Sanitari (APSS), Trento, Italy
| | - Francesco Tommasino
- Department of Physics, University of Trento, Trento, Italy; Trento Institute for Fundamental Physics and Applications (TIFPA), National Institute of Nuclear Physics (INFN), Trento, Italy
| | - Maurizio Centonze
- Department of Diagnostic Imaging, Azienda Provinciale per i Servizi Sanitari (APSS), Trento, Italy
| | - Maurizio Amichetti
- Proton Therapy Department, Azienda Provinciale per i Servizi Sanitari (APSS), Trento, Italy
| | - Maurizio Del Greco
- Department of Cardiac, Santa Maria del Carmine Hospital, Azienda Provinciale per i Servizi Sanitari (APSS), Rovereto, Italy
| |
Collapse
|
50
|
Anselmino M, De Ferrari GM. Future Perspectives and New "Frontiers" in Cardiac Rhythmology. Front Cardiovasc Med 2020; 7:126. [PMID: 33005631 PMCID: PMC7479197 DOI: 10.3389/fcvm.2020.00126] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2020] [Accepted: 06/16/2020] [Indexed: 12/28/2022] Open
Abstract
In the last three decades the Cardiac Rhythmology field has experienced tremendous change and evolution. Our understanding of the underlying mechanism of arrhythmic diseases has dramatically improved, starting from the genetic and molecular mechanisms. Innovative pharmacological and non-pharmacological treatment options have been introduced, and arrhythmias previously considered “untreatable” are now successfully managed in most referral centers. The increasing awareness of the detrimental effects of arrhythmias on any underlying cardiac substrate, targeted as a potentially modifiable cause, has therefore led to an increasingly stronger effort in developing novel methods and approaches to treat arrhythmia and improve patients' health and quality of life. Of all potentially significant developments in the field, we have decided to focus on the approaches generally applicable to multiple arrhythmic cardiac disorders and related to the advancement of technology. More specifically, we will deal with electroanatomical mapping and lesion creation during interventional procedures.
Collapse
Affiliation(s)
- Matteo Anselmino
- Division of Cardiology, Department of Medical Sciences, "Città Della Salute e Della Scienza di Torino" Hospital, University of Turin, Turin, Italy
| | - Gaetano Maria De Ferrari
- Division of Cardiology, Department of Medical Sciences, "Città Della Salute e Della Scienza di Torino" Hospital, University of Turin, Turin, Italy
| |
Collapse
|