1
|
Zhao L, Lin Z, Ju D, Ni J, Ma Y, Chen B, Li X, Sun C, Zheng J, Zhang H, Hou S, Li P, Song S, Guo L. Simultaneous determination of multiple endocrine disrupting chemicals in human amniotic fluid samples by solid phase extraction coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS). Talanta 2025; 293:128088. [PMID: 40188672 DOI: 10.1016/j.talanta.2025.128088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2025] [Revised: 03/31/2025] [Accepted: 04/02/2025] [Indexed: 05/14/2025]
Abstract
Prenatal exposure to endocrine-disrupting chemicals (EDCs) may lead to immediate and long-term adverse health effects in the offspring. The occurrence levels of EDCs in amniotic fluid (AF) have significant influence on fetus prior to birth. In this study, an analytical method for simultaneous determination of a total of 59 widely concerned EDCs, including 11 bisphenols (BPs), 4 parabens, 11 phthalate metabolites (mPAEs), 7 organophosphate metabolites (mOPEs), 8 polycyclic aromatic hydrocarbons metabolites (OH-PAHs) and 18 perfluorinated compounds (PFASs), in human AF samples was developed employing solid phase extraction (SPE) coupled with liquid chromatography tandem mass spectrometry (LC-MS/MS). Key parameters of SPE procedures were carefully investigated. The developed method enabled the determination of 59 EDCs in a low sample volume (500 μL) with LOD and LOQ values in the range of 0.02-0.2 ng/mL and 0.07-0.66 ng/mL, respectively. The recoveries (60.95 %-144.74 %) and precisions (<44 %) were obtained. To further verify the method, AF samples from Tianjin of China were collected and analyzed. The detected concentrations of BPs, parabens, mPAEs, mOsPEs, and PFASs ranged from < LOD-60.48 ng/mL, indicating satisfying performance for field samples. Furthermore, the results of AGREEprep, ComplexGAPI and BAGI exhibited good environmental friendliness and applicability of the developed method.
Collapse
Affiliation(s)
- Lei Zhao
- School of Disaster and Emergency Medicine, Tianjin University, Tianjin, 300072, China; The First School of Medicine, Wenzhou Medical University, Wenzhou, 325035, Zhejiang, China; Wenzhou Safety (Emergency) Institute, Tianjin University, Wenzhou, 325000, Zhejiang, China
| | - Zi Lin
- School of Disaster and Emergency Medicine, Tianjin University, Tianjin, 300072, China; Wenzhou Safety (Emergency) Institute, Tianjin University, Wenzhou, 325000, Zhejiang, China
| | - Duan Ju
- Department of Gynecology and Obstetrics, Tianjin Medical University General Hospital, Tianjin, 300070, China; Tianjin Key Laboratory of Female Reproductive Health and Eugenics, Tianjin Medical University General Hospital, Tianjin, 300070, China
| | - Jiayan Ni
- The First School of Medicine, Wenzhou Medical University, Wenzhou, 325035, Zhejiang, China; Wenzhou Safety (Emergency) Institute, Tianjin University, Wenzhou, 325000, Zhejiang, China
| | - Yuxuan Ma
- School of Disaster and Emergency Medicine, Tianjin University, Tianjin, 300072, China; Wenzhou Safety (Emergency) Institute, Tianjin University, Wenzhou, 325000, Zhejiang, China
| | - Bin Chen
- Wenzhou Safety (Emergency) Institute, Tianjin University, Wenzhou, 325000, Zhejiang, China
| | - Xiaozhou Li
- Department of Gynecology and Obstetrics, Tianjin Medical University General Hospital, Tianjin, 300070, China; Tianjin Key Laboratory of Female Reproductive Health and Eugenics, Tianjin Medical University General Hospital, Tianjin, 300070, China
| | - Congcong Sun
- Department of Scientific Research Center, The Third Clinical Institute Affiliated of Wenzhou Medical University, The Third Affiliated of Shanghai University, Wenzhou People's Hospital, Wenzhou Maternal and Child Health Care Hospital, Wenzhou, 325000, Zhejiang, China
| | - Jianqiong Zheng
- Department of Scientific Research Center, The Third Clinical Institute Affiliated of Wenzhou Medical University, The Third Affiliated of Shanghai University, Wenzhou People's Hospital, Wenzhou Maternal and Child Health Care Hospital, Wenzhou, 325000, Zhejiang, China
| | - Hongping Zhang
- Department of Scientific Research Center, The Third Clinical Institute Affiliated of Wenzhou Medical University, The Third Affiliated of Shanghai University, Wenzhou People's Hospital, Wenzhou Maternal and Child Health Care Hospital, Wenzhou, 325000, Zhejiang, China
| | - Shike Hou
- School of Disaster and Emergency Medicine, Tianjin University, Tianjin, 300072, China; The First School of Medicine, Wenzhou Medical University, Wenzhou, 325035, Zhejiang, China; Wenzhou Safety (Emergency) Institute, Tianjin University, Wenzhou, 325000, Zhejiang, China
| | - Penghui Li
- School of Environmental Science and Safety Engineering, Tianjin University of Technology, Tianjin, 300382, China.
| | - Shanjun Song
- National Institute of Metrology, Beijing, 100029, China.
| | - Liqiong Guo
- School of Disaster and Emergency Medicine, Tianjin University, Tianjin, 300072, China; The First School of Medicine, Wenzhou Medical University, Wenzhou, 325035, Zhejiang, China; Wenzhou Safety (Emergency) Institute, Tianjin University, Wenzhou, 325000, Zhejiang, China.
| |
Collapse
|
2
|
Yang Z, Yu Q, Wu Y, Yuan J, Dong S, Li S, Sun Y, Tang J, Lin N, He Y, Lin Z. Facile synthesis of hierarchically flower-like hollow covalent organic frameworks for enrichment and metabolic analysis of benzophenone derivatives in mouse serum. J Chromatogr A 2025; 1743:465718. [PMID: 39864222 DOI: 10.1016/j.chroma.2025.465718] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2024] [Revised: 01/16/2025] [Accepted: 01/23/2025] [Indexed: 01/28/2025]
Abstract
Benzophenone derivatives (BPs), as synthetic chemicals widely used in personal care products, have drawn increasing attention due to their potential health risks. However, monitoring BPs in biological samples remains challenging due to their complex matrices and the deficiency in sensitivity and selectivity in current methods. Herein, a method combining hierarchically flower-like hollow covalent organic frameworks (HFH-COFs) with high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was established for the enrichment and detection of BPs in serum samples. The HFH-COFs were synthesized at room temperature and employed as an adsorbent due to their advantageous properties. The as-prepared HFH-COFs exhibited high specific surface area (2286.53 m²/g), excellent chemical stability, and good thermal stability, making them ideal for efficient enrichment applications. Under optimized experimental conditions, five BPs were effectively enriched and quantified by HPLC-MS/MS in the range of 50.0-5000.0 ng/L with good linearity (r > 0.9992). The limit of detections was 0.5-10.0 ng/L. Furthermore, HFH-COFs showed high enrichment factors even over multiple adsorption-desorption cycles. This study proposed a reliable and efficient method for monitoring endocrine-disrupting compounds in complex biological samples and highlighted the potential of HFH-COFs as a superior adsorbent material for BP.
Collapse
Affiliation(s)
- Ziyi Yang
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Qing Yu
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Yijing Wu
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Jiahao Yuan
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Shaofeng Dong
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Songtao Li
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Ying Sun
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Jing Tang
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Na Lin
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Yu He
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Zian Lin
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China.
| |
Collapse
|
3
|
Acevedo JM, Kahn LG, Pierce KA, Carrasco A, Rosenberg MS, Trasande L. Temporal and geographic variability of bisphenol levels in humans: A systematic review and meta-analysis of international biomonitoring data. ENVIRONMENTAL RESEARCH 2025; 264:120341. [PMID: 39522874 PMCID: PMC11863187 DOI: 10.1016/j.envres.2024.120341] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/03/2024] [Revised: 09/30/2024] [Accepted: 11/08/2024] [Indexed: 11/16/2024]
Abstract
INTRODUCTION Bisphenols are endocrine-disrupting chemicals known to contribute to chronic disease across the lifespan. With increased awareness of their health effects, changes in regulation and health behaviors have contributed to reductions in urinary bisphenol A (BPA) levels in the United States, Canada, and Europe. However, global trends in bisphenols outside these regions, especially bisphenol S (BPS) exposure, have been less studied. AIM We examine trends in urinary BPA and BPS concentration in non-occupationally exposed populations, where representative data at a country level is unavailable. METHODS We systematically reviewed studies published between 2000 and 2023 that included urinary bisphenol concentrations. We examined BPA and BPS concentration changes by sampling year, controlling for region, age, and pregnancy status, with and without a quadratic term and geometric mean, via mixed-effects meta-regression models with a random intercept and sensitivity analysis. We identified heterogeneity using Cochran's Q-statistic, I2 index, and funnel plots. RESULTS The final analytic sample consisted of 164 studies. We observed positive non-linear associations between time and BPA concentration internationally (beta: 0.02 ng/mL/year2, 95% CI: [0.01, 0.03]) and in Eastern and Pacific Asia (beta: 0.03 ng/mL/year2, 95% CI: [0.02, 0.05]). We also observed non-linear associations of time with both BPA and BPS concentrations in the Middle East and South Asia (beta: 0.13 ng/mL/year2, 95% CI: [0.01, 0.25] and beta: 0.29 ng/mL/year2, 95% CI: [-0.50, -0.08], respectively). In the sensitivity analyses excluding studies with geometric or arithmetic mean values, each displayed significant shifts from the main findings with some consistent outcomes occurring internationally and/or in specific regions. Heterogeneity was high across studies, suggesting possible bias in our estimations. CONCLUSIONS Our findings provide evidence for concern about increasing population exposure to BPA and BPS. Further studies estimating attributable disease burden and costs at regional and global levels are warranted to show these chemicals' impact on population health and economies.
Collapse
Affiliation(s)
- Jonathan M Acevedo
- Department of Pediatrics, New York University Grossman School of Medicine, New York, NY, USA.
| | - Linda G Kahn
- Department of Pediatrics, New York University Grossman School of Medicine, New York, NY, USA; Department of Population Health, New York University Grossman School of Medicine, New York, NY, USA
| | - Kristyn A Pierce
- Department of Pediatrics, New York University Grossman School of Medicine, New York, NY, USA
| | - Anna Carrasco
- Department of Pediatrics, New York University Grossman School of Medicine, New York, NY, USA
| | | | - Leonardo Trasande
- Department of Pediatrics, New York University Grossman School of Medicine, New York, NY, USA; Department of Population Health, New York University Grossman School of Medicine, New York, NY, USA; Wagner School of Public Service, New York University, New York, NY, USA
| |
Collapse
|
4
|
Tuzimski T, Szubartowski S, Stążka J, Baczewski K, Janiszewska D, Railean V, Buszewski B, Szultka-Młyńska M. Potential Clinical Application of Analysis of Bisphenols in Pericardial Fluid from Patients with Coronary Artery Disease with the Use of Liquid Chromatography Combined with Fluorescence Detection and Triple Quadrupole Mass Spectrometry. Molecules 2025; 30:140. [PMID: 39795196 PMCID: PMC11722154 DOI: 10.3390/molecules30010140] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/18/2024] [Revised: 12/29/2024] [Accepted: 12/30/2024] [Indexed: 01/13/2025] Open
Abstract
Bisphenols may negatively impact human health. In this study, we propose the use of HPLC-FLD for the simultaneous determination of bisphenols in pericardial fluid samples collected from patients with coronary artery disease undergoing coronary artery bypass surgery. For sample preparation, a fast, simple, and "green" DLLME method was used, achieving mean recovery values in the range of 62%-98% with relative standard deviations between 2% and 6% for all analytes. Quantitative analysis of bisphenols in the samples was then performed by LC-MS/MS on a triple quadrupole (QqQ) mass spectrometer and electrospray ionization (ESI-/ESI+) was applied in the negative and positive ion modes, respectively. The LODs and LOQs ranged from 0.04 ng/mL to 0.37 ng/mL and 0.12 ng/mL to 1.11 ng/mL, respectively. Pericardial fluid was collected from patients with coronary artery disease during coronary artery bypass surgery. Bisphenol residues were identified and quantified in samples from 19 patients. The procedure was successfully applied to the biomonitoring of free forms of 14 bisphenols in pericardial fluid. After statistical examination of the relationships between the selected variables, a strongly positive correlation was found between creatinine kinase and troponin I, as well as the number of venous anastomoses, circulation time, and clamp cap time.
Collapse
Affiliation(s)
- Tomasz Tuzimski
- Department of Physical Chemistry, Faculty of Pharmacy, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland;
| | - Szymon Szubartowski
- Department of Physical Chemistry, Faculty of Pharmacy, Medical University of Lublin, Chodźki 4a, 20-093 Lublin, Poland;
- Doctoral School of Medical University of Lublin, Medical University of Lublin, Chodźki 6, 20-093 Lublin, Poland
| | - Janusz Stążka
- Department of Cardiac Surgery, Medical University of Lublin, Jaczewskiego 8 (USK Nr 4), 20-093 Lublin, Poland; (J.S.); (K.B.)
| | - Kamil Baczewski
- Department of Cardiac Surgery, Medical University of Lublin, Jaczewskiego 8 (USK Nr 4), 20-093 Lublin, Poland; (J.S.); (K.B.)
| | - Daria Janiszewska
- Department of Environmental Chemistry and Bioanalytics, Gagarina 7, Faculty of Chemistry, Nicolaus Copernicus University, 87-100 Torun, Poland; (D.J.); (B.B.); (M.S.-M.)
| | - Viorica Railean
- Department of Infectious, Invasive Diseases and Veterinary Administration, Institute of Veterinary Medicine, Nicolaus Copernicus University in Torun, Gagarina 7, 87-100 Torun, Poland;
- Centre for Modern Interdisciplinary Technologies, Nicolaus Copernicus University, Wilenska 4, 87-100 Torun, Poland
| | - Bogusław Buszewski
- Department of Environmental Chemistry and Bioanalytics, Gagarina 7, Faculty of Chemistry, Nicolaus Copernicus University, 87-100 Torun, Poland; (D.J.); (B.B.); (M.S.-M.)
- Professor Jan Czochralski Kuyavian-Pomeranian Scientific Technological Centre, Krasinskiego 4, 87-100 Torun, Poland
| | - Małgorzata Szultka-Młyńska
- Department of Environmental Chemistry and Bioanalytics, Gagarina 7, Faculty of Chemistry, Nicolaus Copernicus University, 87-100 Torun, Poland; (D.J.); (B.B.); (M.S.-M.)
| |
Collapse
|
5
|
Peris-Pastor G, Lara-Molina EE, Benedé JL, Chisvert A. Boosting miniaturization in clinical analysis: determination of bisphenols in human serum and urine by miniaturized stir bar sorptive dispersive microextraction. Anal Bioanal Chem 2025; 417:155-165. [PMID: 39537970 DOI: 10.1007/s00216-024-05634-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/22/2024] [Revised: 10/24/2024] [Accepted: 10/29/2024] [Indexed: 11/16/2024]
Abstract
In this work, a miniaturized and sustainable method for the determination of endocrine-disrupting bisphenols in human serum and urine employing the miniaturized stir bar sorptive dispersive microextraction (mSBSDME) approach has been developed. As bisphenols are conjugated in the human body to their glucorinated and sulfated forms, an enzymolysis employing a commercial mixture of β-glucuronidase and arylsulfatase was carried out prior to the microextraction procedure to determine their total content. A magnetic covalent organic framework (COF) was employed as the sorbent to carry out the extraction of the analytes from the biological matrixes, showing good extraction performance due to its hydrophobic, π-π, and dipole-dipole interactions with the analytes. As instrumental detection, liquid chromatography-tandem mass spectrometry (LC-MS/MS) was employed to achieve good sensitivity and selectivity. The method was validated for both matrixes, showing good linearity at least up to 100 ng mL-1, limits of detection in the low ng mL-1 range, good precision values (relative standard deviations below 15%), and good accuracy (relative recoveries between 80 and 127%). In order to show the applicability of the developed method, five samples from female volunteers were analyzed with the final aim of offering a practical tool for monitoring the female population's exposure to these highly endocrine-disrupting compounds. This new procedure enhances the implementation of miniaturized sample preparation approaches in biological samples for clinical analysis, giving special relevance to the sustainability of the method.
Collapse
Affiliation(s)
- Guillem Peris-Pastor
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain
| | - Evelin E Lara-Molina
- IVIRMA Barcelona, 08029, Barcelona, Spain
- IVI Foundation IVIRMA Global, Biomedical Research Institute La Fe, 46026, Valencia, Spain
| | - Juan L Benedé
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain.
| | - Alberto Chisvert
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, 46100, Burjassot, Valencia, Spain
| |
Collapse
|
6
|
Gomersall V, Ciglova K, Pulkrabova J. Implementation of Sensitive Method for Determination of Benzophenone and Camphor UV Filters in Human Urine. TOXICS 2024; 12:837. [PMID: 39771052 PMCID: PMC11679341 DOI: 10.3390/toxics12120837] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/14/2024] [Revised: 11/14/2024] [Accepted: 11/18/2024] [Indexed: 01/11/2025]
Abstract
The level of the human body's burden of benzophenone and camphor ultraviolet (UV) filters can be estimated from their urinary levels. The present study describes the implementations and validation of the sensitive analytical method for the analysis of seven benzophenone and two camphor UV filters in urine. Sample preparation includes overnight enzymatic hydrolysis and ethyl acetate extraction followed by purification by dispersive solid-phase extraction using a sorbent Z-Sep. For the analysis, ultra-high performance liquid chromatography coupled with tandem mass spectrometry was used. Validation was performed using a Standard Reference Material® 3673 and an artificially contaminated urine sample. Target analyte recoveries ranged from 79-113% with repeatability expressed as a relative standard deviation of 2-15%. The limits of quantification were between 0.001 and 0.100 ng/mL in urine. This method was subsequently applied to examine the urine samples collected from Czech women. The analytes benzophenone-1 and 4-hydroxy-benzophenone were the most common analytes present in 100% of the samples, whereas benzophenone-3 was quantified in only 90% of the urine samples. The other four determined benzophenone derivatives were quantified in ≤33% of the samples. The derivatives of camphor were not detected in any samples. This method could be applied in biomonitoring studies.
Collapse
Affiliation(s)
| | | | - Jana Pulkrabova
- Department of Food Analysis and Nutrition, Faculty of Food and Biochemical Technology, University of Chemistry and Technology, Prague, Technicka 3, 166 28 Prague, Czech Republic; (V.G.); (K.C.)
| |
Collapse
|
7
|
Marchiandi J, Dagnino S, Zander-Fox D, Green MP, Clarke BO. Characterization of Chemical Exposome in A Paired Human Preconception Pilot Study. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2024; 58:20352-20365. [PMID: 39508786 DOI: 10.1021/acs.est.4c04356] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2024]
Abstract
Parental preconception exposure to synthetic chemicals may have critical influences on fertility and reproduction. Here, we present a robust LC-MS/MS method covering up to 95 diverse xenobiotics in human urine, serum, seminal and follicular fluids to support exposome-wide assessment in reproductive health outcomes. Extraction recoveries of validated analytes ranged from 62% to 137% and limits of quantification from 0.01 to 6.0 ng/mL in all biofluids. We applied the validated method to a preconception cohort of Australian couples (n = 30) receiving fertility treatment. In total, 36 and 38 xenobiotics were detected across the paired biofluids of males and females, respectively, including PFAS, parabens, organic UV-filters, plastic additives, antimicrobials, and other industrial chemicals. Results showed 39% of analytes in males and 37% in females were equally detected in paired serum, urine, and reproductive fluids. The first detection of the sunscreen ingredient avobenzone and the industrial chemical 4-nitrophenol in follicular and seminal fluids suggests they can cross both blood-follicle/testis barriers, indicating potential risks for fertility. Further, the blood-follicle transfer of perfluorobutanoic acid, PFOA, PFHxS, PFOS, and oxybenzone corroborate that serum concentrations can be reliable proxies for assessing exposure within the ovarian microenvironment. In conclusion, we observed significant preconception exposure to multiple endocrine disruptors in couples and identified potential xenobiotics relevant to male and female fertility impairments.
Collapse
Affiliation(s)
- Jaye Marchiandi
- Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria 3010, Australia
| | - Sonia Dagnino
- Transporters in Imaging and Radiotherapy in Oncology (TIRO), School of Medicine, Direction de la Recherche Fondamentale (DRF), Institut des sciences du vivant Fréderic Joliot, Commissariat à l'Energie Atomique et aux énergies alternatives (CEA), Université Côte d'Azur (UCA), 28 Avenue de Valombrose, 06107 Nice, France
- MRC Centre for Environment and Health, Department of Epidemiology and Biostatistics, School of Public Health, Imperial College London, W12 7TA London, U.K
| | - Deirdre Zander-Fox
- Monash IVF Group Pty, Cremorne, Melbourne, Victoria 3121, Australia
- Department of Obstetrics & Gynaecology, Monash University, Clayton, Melbourne, Victoria 3168, Australia
| | - Mark P Green
- Monash IVF Group Pty, Cremorne, Melbourne, Victoria 3121, Australia
- School of BioSciences, University of Melbourne, Victoria 3010, Australia
| | - Bradley O Clarke
- Australian Laboratory for Emerging Contaminants, School of Chemistry, University of Melbourne, Victoria 3010, Australia
| |
Collapse
|
8
|
González-Martín R, Trujillo-Rodríguez MJ, Freire MG, Ayala JH, Pino V. Effervescence tablets based on magnetic ionic liquids as simple microdevices for the in situ dispersive liquid-liquid microextraction of urinary biomarkers. Anal Chim Acta 2024; 1328:343187. [PMID: 39266200 DOI: 10.1016/j.aca.2024.343187] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/17/2024] [Revised: 08/27/2024] [Accepted: 08/29/2024] [Indexed: 09/14/2024]
Abstract
BACKGROUND Magnetic ionic liquids (MILs) have been explored in dispersive liquid-liquid microextraction (DLLME). Their usage allows to substitute centrifugation and/or filtration steps by a quick magnetic separation. Besides, effervescence-assisted DLLME is one of the most known options to improve the dispersion of the extractant in the sample, while allowing to avoid the consumption of external energy during dispersion. Despite these interesting features, only one study incorporates MILs containing the tetrachloroferrate anion in effervescence tablets. These MILs are highly viscous and liquid at room temperature, thus compromising the stability of the tablets when used as extraction microdevices in effervescence-assisted DLLME, and only allowing their use in the conventional MIL-DLLME mode. RESULTS A new class of effervescence tablets containing a Ni(II)-based MIL, that is solid at room temperature, is here proposed. This type of tablets permits their use, for first time, in the in situ DLLME mode, occurring through the transformation of a water-soluble MIL into a water-insoluble MIL microdroplet. This way, the tablet formulation included: the MIL, the metathesis reagent lithium bis[(trifluoromethyl)sulfonyl]imide, NaH2PO4 and K2CO3 as effervescence precursors salts, and Na2SO4 as salting-out and desiccating agent. The method is combined with high-performance liquid-chromatography and both fluorescence and ultraviolet detection, for the determination of monohydroxylated polycyclic aromatic hydrocarbons (OH-PAHs) and benzophenones (BPs), as biomarkers in urine. The method simply involved the addition of the effervescence tablet to the sample, thus taken place simultaneously the effervescence process and the metathesis reaction, without requiring any external energy consumption. The method presented limits of detection down to 10 ng L-1 for OH-PAHs and to 0.60 μg L-1 for BPs, inter-day relative standard deviations lower than 17 %, and average relative recoveries of 94 % in urine. The determined OH-PAHs contents in urine were between 0.40 and 16 μg L-1, and between 17.8 and 334 μg L-1 for BPs. SIGNIFICANCE We have developed the first MIL-based effervescence tablets that are completely solid, thus improving the stability and robustness of these microdevices with respect to previously reported tablets involving MILs, while permitting to perform into the in situ DLLME mode (thus gaining in extraction efficiency). This approach including the MIL-based effervescence tablets constitutes an alternative on-site platform for the analysis of urine, as satisfactory precision, accuracy, and sensitivity are achieved despite not involving any external energy input within the analytical sample preparation setup. This method also constitutes the first application of MIL-based effervescence tablets for bioanalysis.
Collapse
Affiliation(s)
- Raúl González-Martín
- Laboratorio de Materiales para Análisis Químico (MAT4LL), Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), 38206, San Cristóbal de La Laguna, Spain; Unidad de Investigación de Bioanalítica y Medio Ambiente, Instituto Universitario de Enfermedades Tropicales y Salud Pública de Canarias (IUETSP), ULL, 38206, San Cristóbal de La Laguna, Spain.
| | - María J Trujillo-Rodríguez
- Laboratorio de Materiales para Análisis Químico (MAT4LL), Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), 38206, San Cristóbal de La Laguna, Spain; Unidad de Investigación de Bioanalítica y Medio Ambiente, Instituto Universitario de Enfermedades Tropicales y Salud Pública de Canarias (IUETSP), ULL, 38206, San Cristóbal de La Laguna, Spain; CICECO - Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, 3810-193, Aveiro, Portugal.
| | - Mara G Freire
- CICECO - Aveiro Institute of Materials, Department of Chemistry, University of Aveiro, 3810-193, Aveiro, Portugal.
| | - Juan H Ayala
- Laboratorio de Materiales para Análisis Químico (MAT4LL), Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), 38206, San Cristóbal de La Laguna, Spain.
| | - Verónica Pino
- Laboratorio de Materiales para Análisis Químico (MAT4LL), Departamento de Química, Unidad Departamental de Química Analítica, Universidad de La Laguna (ULL), 38206, San Cristóbal de La Laguna, Spain; Unidad de Investigación de Bioanalítica y Medio Ambiente, Instituto Universitario de Enfermedades Tropicales y Salud Pública de Canarias (IUETSP), ULL, 38206, San Cristóbal de La Laguna, Spain; Centro de Investigación Biomédica en Red de Enfermedades Infecciosas (Ciberinfec), Instituto de Salud Carlos III, 28029, Madrid, Spain.
| |
Collapse
|
9
|
Kakuda P, de Souza ID, Covari LF, Tumas V, Queiroz MEC. Cortisol and cortisone determination by disposable pipette extraction (DPX) and ultra-efficient liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) in urine and saliva samples from patients with Parkinson's disease. Anal Bioanal Chem 2024; 416:6589-6600. [PMID: 39327306 DOI: 10.1007/s00216-024-05557-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2024] [Revised: 09/12/2024] [Accepted: 09/17/2024] [Indexed: 09/28/2024]
Abstract
Higher serum cortisol levels appear to be associated with stress that can overlap or manifest anxiety, fatigue, depression, and sleep dysfunction. These are common and intrusive non-motor symptoms of Parkinson's disease (PD). Thus, stress has been proposed to mediate Parkinson's disease development, and cortisol has been suggested as a biomarker for the generation of stress-related symptoms in Parkinson's disease. This study describes sensitive and robust disposable pipette extraction (DPX) and ultra-efficient liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method to determine cortisol and cortisone (as potential endocrine biomarkers for Parkinson's disease) in 24-h urine and saliva samples obtained from Parkinson's disease patients. Important parameters on DPX extraction were optimized to achieve the best extraction recovery and cleanup efficiency. The proposed method was linear from 0.5 (lower limit of quantification) to 500 ng mL-1 for cortisol and from 3.0 (lower limit of quantification) to 500 ng mL-1 for cortisone. To determine whether urinary cortisol and urinary cortisone are adequate as biomarkers to evaluate the level of anxiety in patients suffering from Parkinson's disease, twenty-nine Parkinson's disease patients (18 with anxiety and 11 without anxiety) were selected for urine analysis. Based on the obtained results, 24-h urine samples obtained from Parkinson's disease patients with anxiety had higher cortisone levels than samples obtained from healthy controls. Receiving operating curves (ROC) analysis, which presented the area under the ROC curve (AUC = 0.733), showed that urinary cortisone levels (µg/24-h urine) were sensitive (56.3%) and specific (93.3%) for distinguishing Parkinson's disease patients with anxiety from healthy controls. In terms of salivary results, PD patients' samples taken 30 min after waking up had higher cortisol and cortisone levels than healthy controls, while their samples taken at night had lower cortisol and cortisone levels.
Collapse
Affiliation(s)
- Priscila Kakuda
- Department of Pharmaceutical Sciences, School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil
| | - Israel Donizeti de Souza
- Departamento de Química, Faculdade de Filosofia Ciências E Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, Brazil
| | - Larissa Fritz Covari
- Departamento de Química, Faculdade de Filosofia Ciências E Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, Brazil
| | - Vitor Tumas
- Department of Neuroscience and Behavior, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, Brazil
| | - Maria Eugênia Costa Queiroz
- Department of Pharmaceutical Sciences, School of Pharmaceutical Sciences of Ribeirão Preto, University of São Paulo, Ribeirão Preto, Brazil.
- Departamento de Química, Faculdade de Filosofia Ciências E Letras de Ribeirão Preto, Universidade de São Paulo, Ribeirão Preto, Brazil.
| |
Collapse
|
10
|
Tu Y, Li H, Xue Y, Xie W, Chen C, Zhong Y, Lin Z, Cai Z. Fluorine-functionalized covalent organic framework coated solid-phase microextraction probe coupled with electrospray ionization mass spectrometry for monitoring triclosan, triclocarban, and chlorophenols in mice. Talanta 2024; 278:126503. [PMID: 38963976 DOI: 10.1016/j.talanta.2024.126503] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2023] [Revised: 06/07/2024] [Accepted: 07/01/2024] [Indexed: 07/06/2024]
Abstract
Triclosan (TCS), triclocarban (TCC), and chlorophenols (CPs) are broad-spectrum antibacterials widely used in dermatological and oral hygiene products, which could induce severe liver and intestine injuries. Hence, it is essential to establish a rapid and sensitive method to monitor TCS, TCC, and CPs in various organisms. In this work, fluorine-functionalized covalent organic framework (COF-F) was prepared by using 4,4',4''-(1,3,5-triazine-2,4,6-triyl)tri-aniline and 2,3,5,6-tetrafluoroterephthalaldehyde as two building units and employed as a solid phase microextraction (SPME) probe for the extraction of TCS, TCC and CPs. The COF-F possessed excellent hydrophobicity, a large specific surface area (1354.3 m2 g-1) and high uniform porosity (3.2 nm), which facilitated high selectivity and adsorption properties towards TCS, TCC, and CPs. Therefore, the as-prepared COF-F-SPME in combination with electrospray ionization mass spectrometry has been developed to provide fast and ultrasensitive detection of TCS, TCC, and CPs in biological samples. The established method demonstrated satisfactory linear ranges (0.01-100.00 μg L-1) and low limits of detection (0.003-0.040 μg L-1) for TCS, TCC and CPs. The developed method could be successfully applied to detect TCS, TCC and CPs in the liver and kidney tissues of mice, demonstrating the potential for the detection of chlorinated aromatic pollutants in the biological samples.
Collapse
Affiliation(s)
- Yuxin Tu
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Heming Li
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Yuandi Xue
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Wen Xie
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Canrong Chen
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Yanhui Zhong
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China
| | - Zian Lin
- Ministry of Education Key Laboratory of Analytical Science for Food Safety and Biology, Fujian Provincial Key Laboratory of Analysis and Detection Technology for Food Safety, College of Chemistry, Fuzhou University, Fuzhou, Fujian, 350108, China.
| | - Zongwei Cai
- State Key Laboratory of Environmental and Biological Analysis, Department of Chemistry, Hong Kong Baptist University, 224 Waterloo Road, Kowloon Tong, Hong Kong SAR, China.
| |
Collapse
|
11
|
Rafeletou A, Niemi JVL, Lagunas-Rangel FA, Liu W, Kudłak B, Schiöth HB. The exposure to UV filters: Prevalence, effects, possible molecular mechanisms of action and interactions within mixtures. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 928:170999. [PMID: 38458461 DOI: 10.1016/j.scitotenv.2024.170999] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/03/2023] [Revised: 01/31/2024] [Accepted: 02/13/2024] [Indexed: 03/10/2024]
Abstract
Substances that can absorb sunlight and harmful UV radiation such as organic UV filters are widely used in cosmetics and other personal care products. Since humans use a wide variety of chemicals for multiple purposes it is common for UV filters to co-occur with other substances either in human originating specimens or in the environment. There is increasing interest in understanding such co-occurrence in form of potential synergy, antagonist, or additive effects of biological systems. This review focuses on the collection of data about the simultaneous occurrence of UV filters oxybenzone (OXYB), ethylexyl-methoxycinnamate (EMC) and 4-methylbenzylidene camphor (4-MBC) as well as other classes of chemicals (such as pesticides, bisphenols, and parabens) to understand better any such interactions considering synergy, additive effect and antagonism. Our analysis identified >20 different confirmed synergies in 11 papers involving 16 compounds. We also highlight pathways (such as transcriptional activation of estrogen receptor, promotion of estradiol synthesis, hypothalamic-pituitary-gonadal (HPG) axis, and upregulation of thyroid-hormone synthesis) and proteins (such as Membrane Associated Progesterone Receptor (MAPR), cytochrome P450, and heat shock protein 70 (Hsp70)) that can act as important key nodes for such potential interactions. This article aims to provide insight into the molecular mechanisms on how commonly used UV filters act and may interact with other chemicals.
Collapse
Affiliation(s)
- Alexandra Rafeletou
- Department of Surgical Sciences, Functional Pharmacology and Neuroscience, Uppsala University, Uppsala, Sweden
| | - Jenni Viivi Linnea Niemi
- Department of Surgical Sciences, Functional Pharmacology and Neuroscience, Uppsala University, Uppsala, Sweden
| | | | - Wen Liu
- Department of Surgical Sciences, Functional Pharmacology and Neuroscience, Uppsala University, Uppsala, Sweden
| | - Błażej Kudłak
- Department of Analytical Chemistry, Faculty of Chemistry, Gdańsk University of Technology, 11/12 Narutowicza Str., Gdańsk 80-233, Poland
| | - Helgi B Schiöth
- Department of Surgical Sciences, Functional Pharmacology and Neuroscience, Uppsala University, Uppsala, Sweden.
| |
Collapse
|
12
|
Hyder A, Ali A, Buledi JA, Memon R, Al-Anzi BS, Memon AA, Kazi M, Solangi AR, Yang J, Thebo KH. A NiO-nanostructure-based electrochemical sensor functionalized with supramolecular structures for the ultra-sensitive detection of the endocrine disruptor bisphenol S in an aquatic environment. Phys Chem Chem Phys 2024; 26:10940-10950. [PMID: 38526327 DOI: 10.1039/d4cp00138a] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 03/26/2024]
Abstract
Herein, NiO nanoparticles (NPs) functionalized with a para-hexanitrocalix[6]arene derivative (p-HNC6/NiO) were synthesized by using a facile method and applied as a selective electrochemical sensor for the determination of bisphenol S (BPS) in real samples. Moreover, the functional interactions, phase purities, surface morphologies and elemental compositions of the synthesized p-HNC6/NiO NPs were investigated via advanced analytical tools, such as Fourier-transform infrared (FT-IR) spectroscopy, X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) and energy dispersive X-ray spectroscopy (EDX). Additionally, the synthesized p-HNC6/NiO NPs were cast on the surface of a bare glassy carbon electrode (GCE) via a drop casting method, which resulted in uniform deposition of p-HNC6/NiO/GCE over the surface of the GCE. Additionally, the developed p-HNC6/NiO/GCE sensor demonstrated an outstanding electrochemical response to BPS under optimized conditions, including a supporting electrolyte, a Briton-Robinson buffer electrolyte at pH 4, a scan rate of 110 mV s-1 and a potential window of between -0.2 and 1.0 V. The wide linear dynamic range was optimized to 0.8-70 μM to obtain a brilliant linear calibration curve for BPS. The limit of detection (LOD) and limit of quantification (LOQ) of the developed sensor were estimated to be 0.0059 and 0.019 μM, respectively, which are lower than those of reported sensors for BPS. The feasibility of the developed method was successfully assessed by analyzing the content of BPS in waste water samples, and good recoveries were achieved.
Collapse
Affiliation(s)
- Ali Hyder
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080, Pakistan.
| | - Akbar Ali
- State Key Laboratory of Multi-phase Complex Systems, Institute of Process Engineering (IPE), Chinese Academy of Sciences, Beijing 100F190, China.
- University of the Chinese Academy of Sciences, 19A Yuquan Road, Beijing 100049, China
| | - Jamil Ahmed Buledi
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080, Pakistan.
| | - Roomia Memon
- Sabanci University, SUNUM Nanotechnology Research and Application Center, Tuzla, 34956, Istanbul, Turkey
| | - Bader S Al-Anzi
- Department of Environmental Sciences, Kuwait University, P.O. Box 5969, Safat, 13060, Kuwait.
| | - Ayaz Ali Memon
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080, Pakistan.
| | - Mohsin Kazi
- Department of Pharmaceutics, College of Pharmacy, King Saud University, P.O. Box-2457, Riyadh 11451, Saudi Arabia
| | - Amber Rehana Solangi
- National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro 76080, Pakistan.
| | - Jun Yang
- State Key Laboratory of Multi-phase Complex Systems, Institute of Process Engineering (IPE), Chinese Academy of Sciences, Beijing 100F190, China.
- University of the Chinese Academy of Sciences, 19A Yuquan Road, Beijing 100049, China
| | - Khalid Hussain Thebo
- Institute of Metal Research (IMR), Chinese Academy of Science, 2 Wenhua Rood, Shenyang, China.
| |
Collapse
|
13
|
Zheng Y, Liu Y, Zhang Z, Hua L, Fang J, Wang L, Zhao H. A fast method for the determination of personal care product chemicals in human urine using dispersive liquid-liquid extraction and ultra high-performance liquid chromatography-tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2024; 38:e9684. [PMID: 38355878 DOI: 10.1002/rcm.9684] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/23/2023] [Revised: 11/26/2023] [Accepted: 11/27/2023] [Indexed: 02/16/2024]
Abstract
RATIONALE Personal care product chemicals (PCPCs) are the chemicals used in personal care products. Many of them are endocrine disruptors and have potential adverse effects on humans. The concentrations of PCPCs in urine are the main biomarker for assessing human exposure. METHODS A method was developed for the simultaneous determination of 14 PCPCs in human urine using dispersive liquid-liquid extraction combined with ultra high-performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS). RESULTS Compared with liquid-liquid extraction, this method had the advantages of time efficiency, sensitivity, and limited organic solvent consumption. It produced good linearity (0.9965-0.9996), limits of detection (2.82-36.36 pg mL-1 ), limits of quantitation (9.39-121.08 pg mL-1 ), matrix effect (-0.90%-2.55%), intra-day precision (relative standard deviations [RSDs] <15%), and inter-day precision (RSDs <19.9%). The method had satisfactory relative recovery at three concentration levels. CONCLUSIONS A rapid method was developed for the simultaneous quantification of 14 PCPCs in human urine. The practicability of the method was verified with 21 urine from university students. It is expected that this method will provide a powerful reference for the assessment of exposure to PCPCs in large populations.
Collapse
Affiliation(s)
- Yawen Zheng
- Ministry of Education Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin, China
| | - Yarui Liu
- Ministry of Education Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin, China
| | - Zining Zhang
- Ministry of Education Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin, China
| | - Liting Hua
- Ministry of Education Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin, China
| | - Jing Fang
- Ministry of Education Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin, China
| | - Lei Wang
- Ministry of Education Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin, China
| | - Hongzhi Zhao
- Ministry of Education Key Laboratory of Pollution Processes and Environmental Criteria, College of Environmental Science and Engineering, Nankai University, Tianjin, China
| |
Collapse
|
14
|
Rozaini MNH, Khoo KS, Abdah MAAM, Ethiraj B, Alam MM, Anwar AF, Yunus NM, Liew CS, Lim JW, Ho CD, Tong WY. Potential application of 2D nano-layered MXene in analysing and remediating endocrine disruptor compounds and heavy metals in water. ENVIRONMENTAL GEOCHEMISTRY AND HEALTH 2024; 46:111. [PMID: 38466501 DOI: 10.1007/s10653-024-01917-4] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/23/2023] [Accepted: 02/15/2024] [Indexed: 03/13/2024]
Abstract
With the advancement of technologies and growth of the economy, it is inevitable that more complex processes are deployed, producing more heterogeneous wastewater that comes from biomedical, biochemical and various biotechnological industries. While the conventional way of wastewater treatment could effectively reduce the chemical oxygen demand, pH and turbidity of wastewater, trace pollutants, specifically the endocrine disruptor compounds (EDCs) that exist in µg L-1 or ng L-1 have further hardened the detection and removal of these biochemical pollutants. Even in small amounts, EDC could interfere human's hormone, causing severe implications on human body. Hence, this review elucidates the recent insights regarding the effectiveness of an advanced 2D material based on titanium carbide (Ti3C2Tx), also known as MXene, in detecting and removing EDCs. MXene's highly tunable feature also allows its surface chemistry to be adjusted by adding chemicals with different functional groups to adsorb different kinds of EDCs for biochemical pollution mitigation. At the same time, the incorporation of MXene into sample matrices also further eases the analysis of trace pollutants down to ng L-1 levels, thereby making way for a more cleaner and comprehensive wastewater treatment. In that sense, this review also highlights the progress in synthesizing MXene from the conventional method to the more modern approaches, together with their respective key parameters. To further understand and attest to the efficacy of MXene, the limitations and current gaps of this potential agent are also accentuated, targeting to seek resolutions for a more sustainable application.
Collapse
Affiliation(s)
- Muhammad Nur' Hafiz Rozaini
- Department of Fundamental and Applied Sciences, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Kuan Shiong Khoo
- Department of Chemical Engineering and Materials Science, Yuan Ze University, Taoyuan, Taiwan
| | | | - Baranitharan Ethiraj
- Department of Biotechnology, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India
| | - Mohammad Mahtab Alam
- Department of Basic Medical Sciences, College of Applied Medical Science, King Khalid University, 61421, Abha, Saudi Arabia
| | - Aliya Fathima Anwar
- Department of Biotechnology, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, India
| | - Normawati M Yunus
- Centre of Research in Ionic Liquids (CORIL), Department of Fundamental and Applied Sciences, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Perak Darul Ridzuan, Malaysia
| | - Chin Seng Liew
- HICoE-Centre for Biofuel and Biochemical Research, Institute of Self-Sustainable Building, Department of Fundamental and Applied Sciences, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Perak Darul Ridzuan, Malaysia.
| | - Jun Wei Lim
- HICoE-Centre for Biofuel and Biochemical Research, Institute of Self-Sustainable Building, Department of Fundamental and Applied Sciences, Universiti Teknologi PETRONAS, 32610, Seri Iskandar, Perak Darul Ridzuan, Malaysia.
- Centre for Herbal Pharmacology and Environmental Sustainability, Chettinad Hospital and Research Institute, Chettinad Academy of Research and Education, Kelambakkam, Tamil Nadu, 603103, India.
| | - Chii-Dong Ho
- Department of Chemical and Materials Engineering, Tamkang University, Tamsui, 251301, New Taipei, Taiwan
| | - Woei-Yenn Tong
- Universiti Kuala Lumpur, Institute of Medical Science Technology, A1-1, Jalan TKS 1, Taman Kajang Sentral, 43000, Kajang, Selangor, Malaysia.
| |
Collapse
|
15
|
Vállez-Gomis V, Benedé JL, Lara-Molina E, López-Nogueroles M, Chisvert A. A miniaturized stir bar sorptive dispersive microextraction method for the determination of bisphenols in follicular fluid using a magnetic covalent organic framework. Anal Chim Acta 2024; 1289:342215. [PMID: 38245199 DOI: 10.1016/j.aca.2024.342215] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/22/2023] [Revised: 12/05/2023] [Accepted: 01/03/2024] [Indexed: 01/22/2024]
Abstract
BACKGROUND Bisphenols, particularly bisphenol A (BPA), are the primary monomers used as additives in the manufacturing of many consumer products. The exposure to these compounds is related to endocrine-disrupting and reproductive effects, among others. For this reason, the development of analytical methods for their determination in biological matrixes is needed to monitor the population exposure to these compounds. Their quantification at ovarian level (i.e., follicular fluid) is interesting for the assessment of the bisphenol content to draw conclusions about infertility problems. However, the background does not meet all requirements by focusing mainly on BPA. RESULTS In this work, a miniaturized stir bar sorptive dispersive microextraction (mSBSDME) approach has been developed for the determination of BPA and eight analogues in follicular fluid. In the proposed method, the sample is previously cleaned-up using a zirconia-based solid-phase extraction cartridge, removing proteins and phospholipids, and then subjected to the mSBSDME for the preconcentration of the analytes. For this purpose, a magnetic covalent organic framework was used as sorbent. A Plackett-Burman design was applied to select the significant variables affecting the mSBSDME. Afterwards, the only significant variable (i.e., sorbent amount) was optimized. Under the optimized conditions, the proposed method was properly validated, and satisfactory analytical parameters in terms of linearity (up to 50 ng mL-1), enrichment factors (8.5-14.3), limits of detection in the low ng mL-1 range, and precision (relative standard deviations below 11.5 %) were obtained. Finally, the method was successfully applied to five samples, detecting BPA and other two analogues. SIGNIFICANCE This method expands the potential applicability of the mSBSDME to other low-availability complex matrixes, which would otherwise be difficult to analyze. Moreover, it offers a valuable tool for monitoring the female population's exposure to bisphenols with the final aim of evaluating if infertility problems of women might be associated to the exposure to these highly endocrine disrupting compounds.
Collapse
Affiliation(s)
- Víctor Vállez-Gomis
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, Burjassot, Valencia, 46100, Spain
| | - Juan L Benedé
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, Burjassot, Valencia, 46100, Spain
| | - Evelin Lara-Molina
- IVIRMA Barcelona, Barcelona, 08029, Spain; IVI Foundation IVIRMA Global, Biomedical Research Institute La Fe, Valencia, 46026, Spain
| | - Marina López-Nogueroles
- Analytical Unit Platform, Instituto de Investigación Sanitaria La Fe, Valencia, 46026, Spain
| | - Alberto Chisvert
- GICAPC Research Group, Department of Analytical Chemistry, University of Valencia, Burjassot, Valencia, 46100, Spain.
| |
Collapse
|
16
|
González N, Souza MCO, Cezarette GN, Rocha BA, Devoz PP, Dos Santos LC, Barcelos GRM, Nadal M, Domingo JL, Barbosa F. Evaluation of exposure to multiple organic pollutants in riparian communities of the Brazilian Amazon: Screening levels and potential health risks. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 908:168294. [PMID: 37924872 DOI: 10.1016/j.scitotenv.2023.168294] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2023] [Revised: 10/31/2023] [Accepted: 10/31/2023] [Indexed: 11/06/2023]
Abstract
Organic pollutants are widely distributed in the environment. Due to their physical and chemical characteristics, they tend to be biomagnified in food chains, mainly in aquatic organisms. Therefore, food consumption is a significant route of lifelong exposure. Although the Amazon River basin contains the highest freshwater biodiversity on Earth, there is scarce literature focusing on the levels of organic pollutants in the local population. The present study was aimed at assessing the levels of several environmental pollutants (polycyclic aromatic hydrocarbons, bisphenols, parabens, and benzophenones) in urine samples from riverside communities along the Tapajós and Amazon Rivers in the Brazilian Amazon region. The results show a 100 % detection of naphthalene metabolites (namely, 1-hydroxy-naphthalene (1OH-NAP), 2-hydroxy-naphthalene (2OH-NAP)), with the highest levels belonging to benzylparaben (BzP) (17.3 ng/mL). Gender-specific analysis revealed that women had significantly higher levels of certain PAH metabolites (i.e., 1OH-NAP and 2-hydroxy-fluorene (2OH-FLU)) than men. In turn, most of the evaluated compounds were higher in urine samples from people living near the Amazon River, which presents increased traffic of boats and ships than the Tapajós River. On the other hand, the human health risk assessment suggested that all communities are at risk of suffering non-carcinogenic effects from exposure to PAHs. At the same time, they are also at risk of carcinogenic effects from exposure to benzo[a]pyrene metabolites. Thus, further studies are needed in order to evaluate the potential health effects of exposure to a mixture of these organic pollutants and other contaminants present in the area, such as mercury.
Collapse
Affiliation(s)
- Neus González
- University of Sao Paulo, School of Pharmaceutical Sciences of Ribeirao Preto, Department of Clinical Analyses, Toxicology and Food Sciences, Analytical and System Toxicology Laboratory, Avenida do Cafe s/n°, 14040-903 Ribeirao Preto, Sao Paulo, Brazil; Universitat Rovira i Virgili, Laboratory of Toxicology and Environmental Health, School of Medicine, Sant Llorenç 21, 43201 Reus, Catalonia, Spain; Institut d'Investigació Sanitària Pere Virgili (IISPV), 43204 Reus, Catalonia, Spain
| | - Marília Cristina Oliveira Souza
- University of Sao Paulo, School of Pharmaceutical Sciences of Ribeirao Preto, Department of Clinical Analyses, Toxicology and Food Sciences, Analytical and System Toxicology Laboratory, Avenida do Cafe s/n°, 14040-903 Ribeirao Preto, Sao Paulo, Brazil.
| | - Gabriel Neves Cezarette
- University of Sao Paulo, School of Pharmaceutical Sciences of Ribeirao Preto, Department of Clinical Analyses, Toxicology and Food Sciences, Analytical and System Toxicology Laboratory, Avenida do Cafe s/n°, 14040-903 Ribeirao Preto, Sao Paulo, Brazil
| | - Bruno Alves Rocha
- University of Sao Paulo, School of Pharmaceutical Sciences of Ribeirao Preto, Department of Clinical Analyses, Toxicology and Food Sciences, Analytical and System Toxicology Laboratory, Avenida do Cafe s/n°, 14040-903 Ribeirao Preto, Sao Paulo, Brazil
| | - Paula Pícoli Devoz
- University of Sao Paulo, School of Pharmaceutical Sciences of Ribeirao Preto, Department of Clinical Analyses, Toxicology and Food Sciences, Analytical and System Toxicology Laboratory, Avenida do Cafe s/n°, 14040-903 Ribeirao Preto, Sao Paulo, Brazil
| | - Lucas Cassulatti Dos Santos
- University of Sao Paulo, School of Pharmaceutical Sciences of Ribeirao Preto, Department of Clinical Analyses, Toxicology and Food Sciences, Analytical and System Toxicology Laboratory, Avenida do Cafe s/n°, 14040-903 Ribeirao Preto, Sao Paulo, Brazil
| | | | - Martí Nadal
- Universitat Rovira i Virgili, Laboratory of Toxicology and Environmental Health, School of Medicine, Sant Llorenç 21, 43201 Reus, Catalonia, Spain; Institut d'Investigació Sanitària Pere Virgili (IISPV), 43204 Reus, Catalonia, Spain
| | - José L Domingo
- Universitat Rovira i Virgili, Laboratory of Toxicology and Environmental Health, School of Medicine, Sant Llorenç 21, 43201 Reus, Catalonia, Spain; Institut d'Investigació Sanitària Pere Virgili (IISPV), 43204 Reus, Catalonia, Spain
| | - Fernando Barbosa
- University of Sao Paulo, School of Pharmaceutical Sciences of Ribeirao Preto, Department of Clinical Analyses, Toxicology and Food Sciences, Analytical and System Toxicology Laboratory, Avenida do Cafe s/n°, 14040-903 Ribeirao Preto, Sao Paulo, Brazil.
| |
Collapse
|
17
|
Hassan RO. Microextraction with smartphone detection of thiocyanate in saliva of tobacco smokers using paper-based analytical method. J Sep Sci 2024; 47:e2300596. [PMID: 37968809 DOI: 10.1002/jssc.202300596] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2023] [Revised: 11/07/2023] [Accepted: 11/08/2023] [Indexed: 11/17/2023]
Abstract
This study presents a novel, cost-effective approach involving spectrophotometric and smartphone paper-based (SPB) methods and a distinctive salting-out air-assisted dispersive microextraction procedure to quantify thiocyanate in saliva samples. The method relies on the inhibitory effect of thiocyanate on quinoneimine dye formation during the Emerson reaction with sodium hypochlorite. Spectrophotometry quantifies the extracted dye by monitoring quinoneimine color intensity reduction at 525 nm. In the SPB method, extracted dye is applied to a paper strip, a smartphone captures the colored paper, and an application analyzes red, green, and blue components. All analyte determination and extraction variables were explored. Both methods exhibit good linearity (10-100 μg/L) with a coefficient of determination of 0.9991 and a limit of detection of 7.5 μg/L for the spectrophotometric method, and a coefficient of determination of 0.9988 and a limit of detection of 8.8 μg/L for the SPB method. The calculated values for the enrichment factor and extraction recovery of the developed extraction methodology were 46% and 93%, respectively. The methods detect thiocyanate in saliva samples, producing results comparable to a validated method.
Collapse
Affiliation(s)
- Rebwar Omar Hassan
- Department of Chemistry, College of Science, Salahaddin University, Erbil, Kurdistan Region, Iraq
| |
Collapse
|
18
|
Alves Rocha B, Gallimberti M, Paulo Bianchi Ximenez J, Giovana Basso C, Joel Martino-Andrade A, Martin Koch H, Augusto Calixto L, Barbosa F. An eco-friendly sample preparation procedure based on air-assisted liquid-liquid microextraction for the rapid determination of phthalate metabolites in urine samples by liquid chromatography-tandem mass spectrometry. Talanta 2024; 266:124974. [PMID: 37494769 DOI: 10.1016/j.talanta.2023.124974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/06/2023] [Revised: 07/07/2023] [Accepted: 07/18/2023] [Indexed: 07/28/2023]
Abstract
Urinary phthalate metabolite (mPAEs) analysis is a reliable tool for assessing human exposure to phthalates. With growing interest in urinary biomonitoring of these metabolites, there is a need for fast and sensitive analytical methods. Therefore, a simple, rapid procedure for simultaneous determination of fifteen phthalate metabolites in human urine samples by liquid chromatography-tandem mass spectrometry was developed. The novelty of the present procedure is based on the use of diethyl carbonate as a green biobased extraction solvent and air-assisted liquid-liquid microextraction (AALLME) as a sample preparation step. A Plackett-Burman design was used for screening the factors that influence the AALLME extraction efficiency of mPAEs. The effective factors were then optimized by response surface methodology using a central composite rotatable design. Under the optimized conditions, good linearity can be achieved in a concentration range of 1.0-20.0 ng mL-1 with correlation coefficients higher than 0.99. The repeatability and reproducibility precision were in the range of 2-12% and 1-10% respectively. Recoveries ranging from 90% to 110%. This, and the low limits of detection, ranging from 0.01 to 0.05 ng mL-1, make the proposed procedure sensitive and suitable for human biomonitoring of phthalate exposures. For proof-of-principle, the new method was used to measure the urinary concentrations of mPAEs in 20 urine samples from Brazilian women. The high frequency of detections and in part high concentrations of mPAEs indicate to widespread exposure to several phthalates among Brazilian women.
Collapse
Affiliation(s)
- Bruno Alves Rocha
- Analytical and System Toxicology Laboratory, Department of Clinical Analyses, Toxicology and Food Sciences, School of Pharmaceutical Sciences of Ribeirao Preto, University of Sao Paulo, Avenida do Cafe s/nº, Ribeirao Preto, Sao Paulo, 14040-903, Brazil.
| | - Matheus Gallimberti
- Analytical and System Toxicology Laboratory, Department of Clinical Analyses, Toxicology and Food Sciences, School of Pharmaceutical Sciences of Ribeirao Preto, University of Sao Paulo, Avenida do Cafe s/nº, Ribeirao Preto, Sao Paulo, 14040-903, Brazil
| | - João Paulo Bianchi Ximenez
- Analytical and System Toxicology Laboratory, Department of Clinical Analyses, Toxicology and Food Sciences, School of Pharmaceutical Sciences of Ribeirao Preto, University of Sao Paulo, Avenida do Cafe s/nº, Ribeirao Preto, Sao Paulo, 14040-903, Brazil
| | - Carla Giovana Basso
- Department of Physiology, Animal Endocrine and Reproductive Physiology Laboratory, Federal University of Paraná (UFPR), Curitiba, Parana, Brazil
| | - Anderson Joel Martino-Andrade
- Department of Physiology, Animal Endocrine and Reproductive Physiology Laboratory, Federal University of Paraná (UFPR), Curitiba, Parana, Brazil
| | - Holger Martin Koch
- Institute for Prevention and Occupational Medicine of the German Social Accident Insurance, Institute of the Ruhr University Bochum (IPA), Bürkle-de-la-Camp-Platz 1, 44789, Bochum, Germany
| | - Leandro Augusto Calixto
- Department of Pharmaceutical Sciences, Institute of Environmental, Chemistry and Pharmaceutical Science, Federal University of São Paulo, São Paulo, 099972-270, Brazil
| | - Fernando Barbosa
- Analytical and System Toxicology Laboratory, Department of Clinical Analyses, Toxicology and Food Sciences, School of Pharmaceutical Sciences of Ribeirao Preto, University of Sao Paulo, Avenida do Cafe s/nº, Ribeirao Preto, Sao Paulo, 14040-903, Brazil
| |
Collapse
|
19
|
Cesila CA, Souza MCO, Cruz JC, Bocato MZ, Campíglia AD, Barbosa F. Biomonitoring of polycyclic aromatic hydrocarbons in Brazilian pregnant women: Urinary levels and health risk assessment. ENVIRONMENTAL RESEARCH 2023; 235:116571. [PMID: 37467941 DOI: 10.1016/j.envres.2023.116571] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/05/2023] [Revised: 06/25/2023] [Accepted: 07/06/2023] [Indexed: 07/21/2023]
Abstract
Over the years, humans have been continuously exposed to several compounds directly generated by industrial processes and/or present in consumed products. Polycyclic aromatic hydrocarbons (PAHs) are legacy pollutants ubiquitous in the environment and represent the main chemical pollutants in urban areas. Worldwide, studies that aim to understand the impacts of exposure to these chemicals have gained increasing prominence due to their potential toxicity profile, mainly concerning genotoxicity and carcinogenicity. Human biomonitoring (HB) is an analytical approach to monitoring population exposure to chemicals; however, these studies are still limited in Brazil. Thus, this work aimed to evaluate the exposure of Brazilian pregnant women to PAHs through HB studies. Besides, the risk characterization of this exposure was performed. For this purpose, urine samples from 358 Brazilian pregnant women were used to evaluate 11 hydroxylated metabolites of PAHs employing gas chromatography coupled to mass spectrometry. The 1OH-naphthol and 2OH-naphthol were detected in 100% of the samples and showed high levels, corresponding to 16.99 and 3.62 μg/g of creatinine, respectively. 2OH-fluorene (8.12 μg/g of creatinine) and 9OH-fluorene (1.26 μg/g of creatinine) were detected in 91% and 66% of the samples, respectively. Benzo(a)pyrene (BaP) metabolites were detected in more than 50% of the samples (0.58-1.26 μg/g of creatinine). A hazard index of 1.4 and a carcinogenic risk above 10-4 were found for BaP metabolites in the risk characterization. Therefore, our findings may indicate that exposure to PAHs poses a potential risk to pregnant women's health and a high probability of carcinogenic risk due to their exposure to BaP. Finally, this work shows the need for more in-depth studies to determine the sources of exposure and the implementation of health protection measures regarding the exposure of the Brazilian population to PAHs.
Collapse
Affiliation(s)
- Cibele Aparecida Cesila
- University of Sao Paulo, School of Pharmaceutical Sciences of Ribeirao Preto, Department of Clinical Analyses, Toxicology, and Food Sciences. ASTox Analytical and System Toxicology Laboratory. Av. do Café s/nº, 14040-903, Ribeirao Preto, Sao Paulo, Brazil
| | - Marília Cristina Oliveira Souza
- University of Sao Paulo, School of Pharmaceutical Sciences of Ribeirao Preto, Department of Clinical Analyses, Toxicology, and Food Sciences. ASTox Analytical and System Toxicology Laboratory. Av. do Café s/nº, 14040-903, Ribeirao Preto, Sao Paulo, Brazil.
| | - Jonas Carneiro Cruz
- University of Sao Paulo, School of Pharmaceutical Sciences of Ribeirao Preto, Department of Clinical Analyses, Toxicology, and Food Sciences. ASTox Analytical and System Toxicology Laboratory. Av. do Café s/nº, 14040-903, Ribeirao Preto, Sao Paulo, Brazil
| | - Mariana Zuccherato Bocato
- University of Sao Paulo, School of Pharmaceutical Sciences of Ribeirao Preto, Department of Clinical Analyses, Toxicology, and Food Sciences. ASTox Analytical and System Toxicology Laboratory. Av. do Café s/nº, 14040-903, Ribeirao Preto, Sao Paulo, Brazil
| | | | - Fernando Barbosa
- University of Sao Paulo, School of Pharmaceutical Sciences of Ribeirao Preto, Department of Clinical Analyses, Toxicology, and Food Sciences. ASTox Analytical and System Toxicology Laboratory. Av. do Café s/nº, 14040-903, Ribeirao Preto, Sao Paulo, Brazil
| |
Collapse
|
20
|
Wu LH, Liu YX, Zhang YJ, Jia LL, Guo Y. Occurrence of bisphenol diglycidyl ethers and bisphenol analogs, and their associations with DNA oxidative damage in pregnant women. ENVIRONMENTAL RESEARCH 2023; 227:115739. [PMID: 36963715 DOI: 10.1016/j.envres.2023.115739] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/01/2022] [Revised: 02/24/2023] [Accepted: 03/21/2023] [Indexed: 05/08/2023]
Abstract
Bisphenol diglycidyl ethers (BDGEs) and Bisphenol A and its analogs (bisphenols) may have the same exposure routes and coexposure phenomenon in sensitive populations such as pregnant women. Previous biomonitoring studies on BDGEs are limited. Levels of fifteen bisphenols, six BDGEs and the DNA oxidative damage biomarker 8-hydroxy-2-deoxyguanosine (8-OHdG) were measured in the urine of pregnant women recruited in south China (n = 358). We aimed to provide the occurrence of bisphenols and BDGEs in pregnant women, and to investigate the potential relationship between their exposure and oxidative stress. Bisphenol A, bisphenol S, bisphenol F, bisphenol AP and all BDGEs (except for BADGE·2HCl) were frequently detected. The total concentrations of all bisphenols and BDGEs were 0.402-338 and 0.104-32.5 ng/mL, with geometric means of 2.87 and 2.48 ng/mL, respectively. BFDGE was the most abundant chemical of BDGEs, with a median concentration of 0.872 ng/mL, followed by BADGE·H2O·HCl (0.297 ng/mL). Except for pre-pregnancy obesity, maternal age/height, employment, fasting in the morning and parity did not affect the urinary concentrations of BDGEs. Significant and weak correlations were observed between concentrations (unadjusted) of total bisphenols and BDGEs (r = 0.389, p < 0.01), indicating their similar sources and exposure routes. The biomarker 8-OHdG was detected in all samples, with concentrations ranging from 1.98 to 32.6 ng/mL (median: 9.96 ng/mL). Levels of 8-OHdG were positively correlated with urinary several bisphenol concentrations (adjusted β range: 0.037-0.089, p < 0.05) but were not correlated with those of BDGEs. Further studies should focus on whether BDGEs and bisphenols exert combined effects on oxidative stress. Our study provided the first BDGEs exposure data in pregnant women and indicated that BDGEs exposure was highly prevalent in pregnant women as early as 2015 in south China.
Collapse
Affiliation(s)
- Liu-Hong Wu
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 510632, China
| | - Yan-Xiang Liu
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 510632, China
| | - Ying-Jie Zhang
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 510632, China
| | - Lu-Lu Jia
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 510632, China
| | - Ying Guo
- Guangdong Key Laboratory of Environmental Pollution and Health, School of Environment, Jinan University, Guangzhou, 510632, China.
| |
Collapse
|
21
|
Zhang D, Lu S. A holistic review on triclosan and triclocarban exposure: Epidemiological outcomes, antibiotic resistance, and health risk assessment. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 872:162114. [PMID: 36764530 DOI: 10.1016/j.scitotenv.2023.162114] [Citation(s) in RCA: 25] [Impact Index Per Article: 12.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/23/2022] [Revised: 01/31/2023] [Accepted: 02/04/2023] [Indexed: 06/18/2023]
Abstract
Triclosan (TCS) and triclocarban (TCC) are antimicrobials that are widely applied in personal care products, textiles, and plastics. TCS and TCC exposure at low doses may disturb hormone levels and even facilitate bacterial resistance to antibiotics. In the post-coronavirus disease pandemic era, chronic health effects and the spread of antibiotic resistance genes associated with TCS and TCC exposure represent an increasing concern. This study sought to screen and review the exposure levels and sources and changes after the onset of the coronavirus disease (COVID-19) pandemic, potential health outcomes, bacterial resistance and cross-resistance, and health risk assessment tools associated with TCS and TCC exposure. Daily use of antimicrobial products accounts for most observed associations between internal exposure and diseases, while secondary exposure at trace levels mainly lead to the spread of antibiotic resistance genes. The roles of altered gut microbiota in multi-system toxicities warrant further attention. Sublethal dose of TCC selects ARGs without obviously increasing tolerance to TCC. But TCS induce persistent TCS resistance and reversibly select antibiotic resistance, which highlights the benefits of minimizing its use. To derive reference doses (RfDs) for humans, more sensitive endpoints observed in populational studies need to be confirmed using toxicological tests. Additionally, the human equivalent dose is recommended to be incorporated into the health risk assessment to reduce uncertainty of extrapolation.
Collapse
Affiliation(s)
- Duo Zhang
- School of Public Health (Shenzhen), Sun Yat-sen University, Shenzhen 518107, China
| | - Shaoyou Lu
- School of Public Health (Shenzhen), Sun Yat-sen University, Shenzhen 518107, China.
| |
Collapse
|
22
|
Lee KM, Han SM, Lee HJ, Kang M, Jeong TY, Son J, Min H, Cha S, Oh HB, Oh WK, Lee J. Influence of mobile phase composition on the analytical sensitivity of LC-ESI-MS/MS for the concurrent analysis of bisphenols, parabens, chlorophenols, benzophenones, and alkylphenols. ENVIRONMENTAL RESEARCH 2023; 221:115305. [PMID: 36642120 DOI: 10.1016/j.envres.2023.115305] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Revised: 01/07/2023] [Accepted: 01/12/2023] [Indexed: 06/17/2023]
Abstract
Phenols are significant environmental endocrine disruptors that can have adverse health effects on exposed individuals. Correlating phenol exposure to potential health implications requires the development of a comprehensive and sensitive analytical method capable of analyzing multiple phenols in a single sample preparation and analytical run. Currently, no such method is available for multiple classes of phenols due to electrospray ionization (ESI) limitations in concurrent ionization and lack of sensitivity to certain phenols, particularly alkylphenols. In this study, we investigated the influence of mobile phase compositions in ESI on concurrent ionization and analytical sensitivity of liquid chromatography-electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS) during the analysis of multiple classes of phenols, and we propose a comprehensive and sensitive analytical method for various classes of phenols (i.e., bisphenols, parabens, benzophenones, chlorophenols, and alkylphenols). The proposed method was affected by 0.5 mM ammonium fluoride under methanol conditions. It enabled the concurrent ionization of all the phenols and significantly improved the analytical sensitivity for bisphenols and alkylphenols, which typically have poor ionization efficiency. This method, combined with a "dilute and shoot" approach, allowed us to simultaneously quantify 38 phenols with good chromatographic behavior and sensitivity. Furthermore, the method was successfully applied to the analysis of 61 urine samples collected from aquatic (swimming) and land (indoor volleyball and outdoor football) athletes.
Collapse
Affiliation(s)
- Kang Mi Lee
- Doping Control Center, Korea Institute of Science and Technology, Hwarang-ro 14-gil 5, Seongbuk-gu, Seoul, 02792, Republic of Korea; Korea Bioactive Natural Material Bank, Research Institute of Pharmaceutical Sciences, College of Pharmacy, Seoul National University, Seoul, 08826, Republic of Korea
| | - Sang Moon Han
- Doping Control Center, Korea Institute of Science and Technology, Hwarang-ro 14-gil 5, Seongbuk-gu, Seoul, 02792, Republic of Korea
| | - Hyeon-Jeong Lee
- Doping Control Center, Korea Institute of Science and Technology, Hwarang-ro 14-gil 5, Seongbuk-gu, Seoul, 02792, Republic of Korea
| | - Minsik Kang
- Doping Control Center, Korea Institute of Science and Technology, Hwarang-ro 14-gil 5, Seongbuk-gu, Seoul, 02792, Republic of Korea
| | - Tae Young Jeong
- Doping Control Center, Korea Institute of Science and Technology, Hwarang-ro 14-gil 5, Seongbuk-gu, Seoul, 02792, Republic of Korea
| | - Junghyun Son
- Doping Control Center, Korea Institute of Science and Technology, Hwarang-ro 14-gil 5, Seongbuk-gu, Seoul, 02792, Republic of Korea
| | - Hophil Min
- Doping Control Center, Korea Institute of Science and Technology, Hwarang-ro 14-gil 5, Seongbuk-gu, Seoul, 02792, Republic of Korea
| | - Sangwon Cha
- Department of Chemistry, Dongguk University, Seoul, 04620, Republic of Korea
| | - Han Bin Oh
- Department of Chemistry, Sogang University, Seoul, 04107, Republic of Korea
| | - Won Keun Oh
- Korea Bioactive Natural Material Bank, Research Institute of Pharmaceutical Sciences, College of Pharmacy, Seoul National University, Seoul, 08826, Republic of Korea.
| | - Jaeick Lee
- Doping Control Center, Korea Institute of Science and Technology, Hwarang-ro 14-gil 5, Seongbuk-gu, Seoul, 02792, Republic of Korea.
| |
Collapse
|
23
|
Shahvalinia M, Larki A, Ghanemi K. Smartphone-based colorimetric determination of triclosan in aqueoussamples after ultrasound assisted-dispersive liquid-liquid microextraction under optimized response surface method conditions. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2022; 278:121323. [PMID: 35526443 DOI: 10.1016/j.saa.2022.121323] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Revised: 03/13/2022] [Accepted: 04/25/2022] [Indexed: 06/14/2023]
Abstract
In the present study, a simple and low cost methodology based on ultrasonic assisted-dispersive liquid-liquid microextraction (UA-DLLME) followed by smartphone-based colorimetric measurement was introduced for the separation and determination of Triclosan (TCS) from contaminated waters. This method is based on the formation of an azo compound from the alkaline reaction of TCS with a diazonium ion, resulting from the reaction of sodium nitrite and p-sulfanilic acid in an acidic medium. The orange-brown color product was extracted into a low volume of organic phase by UA-DLLME method and RGB values were recorded with free Android app Color Grab. The effective parameters in this procedure, namely solution pH, p-sulfanilic acid and nitrite concentration, reaction time and volume of the extraction solvent were investigated and optimized by response surface methodology (RSM) based on a Box-Behnken design (BBD) model. Under optimum conditions, the calibration graph was linear in the range of 3.0 and 200 μg L-1 of TCS. The limit of detection (LOD) and limit of quantification (LOQ) were 0.8 and 2.7 μg L-1, respectively. The proposed method was successfullyused for the analyses of triclosan in several water and wastewater samples and satisfactory results were obtained.
Collapse
Affiliation(s)
- Monireh Shahvalinia
- Department of Marine Chemistry, Faculty of Marine Science, Khorramshahr University of Marine Science and Technology, Khorramshahr, Iran
| | - Arash Larki
- Department of Marine Chemistry, Faculty of Marine Science, Khorramshahr University of Marine Science and Technology, Khorramshahr, Iran.
| | - Kamal Ghanemi
- Department of Marine Chemistry, Faculty of Marine Science, Khorramshahr University of Marine Science and Technology, Khorramshahr, Iran
| |
Collapse
|
24
|
Individual and Simultaneous Electrochemical Detection of Bisphenol A and Bisphenol S in Food Samples Using Triethylenetetramine Functionalized Multi-Walled Carbon Nanotubes. FOOD ANAL METHOD 2022. [DOI: 10.1007/s12161-022-02409-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/04/2022]
|
25
|
Jala A, Varghese B, Kaur G, Rajendiran K, Dutta R, Adela R, Borkar RM. Implications of endocrine-disrupting chemicals on polycystic ovarian syndrome: A comprehensive review. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2022; 29:58484-58513. [PMID: 35778660 DOI: 10.1007/s11356-022-21612-0] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/25/2022] [Accepted: 06/17/2022] [Indexed: 06/15/2023]
Abstract
Polycystic ovarian syndrome (PCOS) is a complex multifactorial disorder of unknown pathogenesis in which genetic and environmental factors contribute synergistically to its phenotypic expressions. Endocrine-disrupting chemicals (EDCs), a group of widespread pollutants freely available in the environment and consumer products, can interfere with normal endocrine signals. Extensive evidence has shown that EDCs, environmental contributors to PCOS, can frequently induce ovarian and metabolic abnormalities at low doses. The current research on environmental EDCs suggests that there may be link between EDC exposure and PCOS, which calls for more human bio-monitoring of EDCs using highly sophisticated analytical techniques for the identification and quantification and to discover the underlying pathophysiology of the disease. This review briefly elaborated on the general etiology of PCOS and listed various epidemiological and experimental data from human and animal studies correlating EDCs and PCOS. This review also provides insights into various analytical tools and sample preparation techniques for biomonitoring studies for PCOS risk assessment. Furthermore, we highlight the role of metabolomics in disease-specific biomarker discovery and its use in clinical practice. It also suggests the way forward to integrate biomonitoring studies and metabolomics to underpin the role of EDCs in PCOS pathophysiology.
Collapse
Affiliation(s)
- Aishwarya Jala
- Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research (NIPER), Guwahati, Changsari, 781101, India
| | - Bincy Varghese
- Department of Pharmacy Practice, National Institute of Pharmaceutical Education and Research (NIPER), Guwahati, Changsari, 781101, India
| | - Gurparmeet Kaur
- Department of Pharmacy Practice, National Institute of Pharmaceutical Education and Research (NIPER), Guwahati, Changsari, 781101, India
| | | | - Ratul Dutta
- Down Town Hospital, Guwahati, Assam, 781106, India
| | - Ramu Adela
- Department of Pharmacy Practice, National Institute of Pharmaceutical Education and Research (NIPER), Guwahati, Changsari, 781101, India
| | - Roshan M Borkar
- Department of Pharmaceutical Analysis, National Institute of Pharmaceutical Education and Research (NIPER), Guwahati, Changsari, 781101, India.
| |
Collapse
|
26
|
Improved method for the determination of endocrine-disrupting chemicals in urine of school-age children using microliquid-liquid extraction and UHPLC-MS/MS. Anal Bioanal Chem 2022; 414:6681-6694. [PMID: 35879427 DOI: 10.1007/s00216-022-04231-z] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/09/2022] [Revised: 06/20/2022] [Accepted: 07/13/2022] [Indexed: 11/01/2022]
Abstract
The presence of endocrine-disrupting chemicals in our daily life is increasing every day and, by extension, human exposure and the consequences thereof. Among these substances are bisphenols and parabens. Urine is used to analyze the exposure. The determination of 12 bisphenol homologues and 6 parabens is proposed. A procedure based on a method previously developed by our research group in 2014 is improved. The extraction yield is higher, because the new protocol is 5 times more efficient. Also, a comparison between calibration with pure standards and matrix calibration, to calculate the matrix effect, was also made. A high grade of matrix effect for all analytes was observed. In terms of validation, the limits of detection (LOD) were between 0.03 and 0.3 ng mL-1 and limits of quantification (LOQ) 0.1 to 1.0 ng mL-1, respectively, and the recovery is higher than 86.4% and lower than 113.6%, with a RSD lower than 13.5% in all cases. A methodology for accurate and sensitive quantification of bisphenol homologues together with parabens in human urine using UHPLC-MS/MS was developed. The method was successfully applied to 30 urine samples from children.
Collapse
|
27
|
Azooz EA, Al-Wani HSA, Gburi MS, Al-Muhanna EHB. Recent modified air-assisted liquid–liquid microextraction applications for medicines and organic compounds in various samples: A review. OPEN CHEM 2022. [DOI: 10.1515/chem-2022-0174] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022] Open
Abstract
Abstract
Air-assisted liquid–liquid microextraction (AALLME) is a procedure for sample preparation that has high recoveries and high preconcentration factors while using a small amount of extractants. This procedure has gained widespread acceptance among scientists due to a variety of advantages, including its easiness, being cheap, green, and available in most laboratories. The current review has focused on the analysis of medicines and organic compounds using various modes of AALLME. The use of various extractants and support factors were developed in many modes of AALLME. A review of literature revealed that the procedure is used as a powerful and efficient approach for extracting medicals and organic compounds. This review explained 12 different types of AALLME methods. The findings on the modifications of AALLME modes that have been published are summarized. Future directions are also being discussed.
Collapse
Affiliation(s)
- Ebaa Adnan Azooz
- Chemistry Department, The Gifted Students’ School in Al-Najaf, Ministry of Education , Al-Najaf , Iraq
- Medical Laboratory Technology Department, College of Medical Technology, The Islamic University , Najaf , Iraq
| | | | - Muna Shakir Gburi
- Chemistry Department, The Gifted Students’ School in Al-Najaf, Ministry of Education , Al-Najaf , Iraq
| | | |
Collapse
|
28
|
Pierri ME, Morés L, Bernardi G, Carasek E. Multiclass determination of endocrine disruptors in urine by hollow fiber microporous membrane and liquid chromatography. Anal Biochem 2022; 652:114725. [PMID: 35597269 DOI: 10.1016/j.ab.2022.114725] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/28/2022] [Revised: 05/04/2022] [Accepted: 05/06/2022] [Indexed: 11/16/2022]
Abstract
A simple and rapid methodology was developed using hollow fiber membrane microporous and a 96-well plate system for a high throughput multiclass determination of endocrine disruptors in human urine (diclofenac, diazepam, carbamazepine, ibuprofen, naproxen, carbofuran, methyl parathion, 17-α-ethynyl estradiol, bisphenol A and benzophenone). The quantification and detection of the chemicals were carried out by an HPLC-diode array detector. The fixed conditions for carrying out the method optimization were 1.5 mL of sample and 300 μL of solvent desorption. Multivariate and univariate models were applied to optimize the parameters of the method, achieving the following conditions: 20% diluted urine, 1-octanol of extraction solvent impregnated in the microporous membrane, 70 min extraction in pH 3.0 and 30 min with a mixture of 75% methanol and 25% acetonitrile (v/v) for the desorption. The R2 were ≤ 0.9973 for ibuprofen. The LOD ranged from 3.3 to 16.7 ng mL-1 and the LOQ from 10 to 50 ng mL-1. Relative recoveries ranged from 71% to 126%. The repeatability (n = 3) ranged from 0.22% to 12.01%, and the intermediate precision (n = 9) ranged from 0.13% to 17.76%. The method presents a good alternative for the determination of different classes of compounds in human urine.
Collapse
Affiliation(s)
- Maria Eduarda Pierri
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, 88040900, SC, Brazil
| | - Lucas Morés
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, 88040900, SC, Brazil
| | - Gabrieli Bernardi
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, 88040900, SC, Brazil
| | - Eduardo Carasek
- Departamento de Química, Universidade Federal de Santa Catarina, Florianópolis, 88040900, SC, Brazil.
| |
Collapse
|
29
|
Chen H, Zhang Y, Li X, Zhang W, He H, Du B, Li T, Tang H, Liu Y, Li L, Shi M. Transcriptome Changes and Potential Immunotoxicity Analysis in RAW264.7 Macrophages Caused by Bisphenol F. Front Pharmacol 2022; 13:846562. [PMID: 35387338 PMCID: PMC8978606 DOI: 10.3389/fphar.2022.846562] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2021] [Accepted: 02/15/2022] [Indexed: 11/17/2022] Open
Abstract
As a viable substitute for bisphenol A (BPA), BPF has been widely used in the plastic industry and daily consumer goods, resulting in its detection in humans at a comparable concentration. Evidence reveals that BPF and BPA may have similar toxic effects due to their similar structures. However, there is less information about BPF and its latent implications on the immune system, which is associated with many disorders. In this study, the in vitro toxicity of BPF on RAW264.7 macrophages was explored. The cells were treated with different concentrations of BPF (5, 10, 20, 50, 100, and 200 μM), the cell viability and apoptosis were detected, the gene expression profile was analyzed by whole-transcriptome sequencing, and the mRNA levels were detected by qRT-PCR. The results showed a high concentration of BPF could significantly reduce the survival rate of RAW264.7 macrophages. Although the medium concentration (20–50 μM) of BPF seemed to have no impact on the cell activity of macrophages, it caused the occurrence of apoptosis. The results of differential transcription showed that compared with the control group, 121 genes were upregulated and 82 genes were downregulated in the BPF group. The significantly changed gene functions were mainly concentrated in cell cycle, phagosome, lysosome, and antigen processing and presentation. These findings provide valuable information for correctly understanding the immunotoxicity risk of BPF and may help to improve the hazard identification of bisphenol compounds.
Collapse
Affiliation(s)
- Huiling Chen
- Dongguan Key Laboratory of Environmental Medicine, School of Public Health, Guangdong Medical University, Dongguan, China
| | - Yanchao Zhang
- Dongguan Key Laboratory of Environmental Medicine, School of Public Health, Guangdong Medical University, Dongguan, China
| | - Xing Li
- Dongguan Key Laboratory of Environmental Medicine, School of Public Health, Guangdong Medical University, Dongguan, China
| | - Wei Zhang
- Dongguan Key Laboratory of Environmental Medicine, School of Public Health, Guangdong Medical University, Dongguan, China
| | - Haoqi He
- Dongguan Key Laboratory of Environmental Medicine, School of Public Health, Guangdong Medical University, Dongguan, China
| | - Bohai Du
- Dongguan Key Laboratory of Environmental Medicine, School of Public Health, Guangdong Medical University, Dongguan, China
| | - Tianlan Li
- Dongguan Key Laboratory of Environmental Medicine, School of Public Health, Guangdong Medical University, Dongguan, China
| | - Huanwen Tang
- Dongguan Key Laboratory of Environmental Medicine, School of Public Health, Guangdong Medical University, Dongguan, China
| | - Yungang Liu
- Department of Toxicology, School of Public Health, Southern Medical University, Guangzhou, China
| | - Li Li
- Dongguan Key Laboratory of Environmental Medicine, School of Public Health, Guangdong Medical University, Dongguan, China
| | - Ming Shi
- Dongguan Key Laboratory of Environmental Medicine, School of Public Health, Guangdong Medical University, Dongguan, China.,Dongguan Liaobu Hospital, Dongguan, China
| |
Collapse
|
30
|
A facial electrochemical method for efficient triclosan detection constructed on dodecanethiol monolayers functioned Au nanoparticles-ErGO. Microchem J 2022. [DOI: 10.1016/j.microc.2021.107144] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
31
|
The Presence of Triclosan in Human Hair Samples in Poland-A Pilot Study. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH 2022; 19:ijerph19073796. [PMID: 35409481 PMCID: PMC8998057 DOI: 10.3390/ijerph19073796] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 02/01/2022] [Revised: 03/11/2022] [Accepted: 03/20/2022] [Indexed: 02/04/2023]
Abstract
Triclosan (TCS) is an organic substance showing antibacterial action, which is commonly used in many branches of industry, including, among others, cosmetics, pharmaceuticals and the food industry. TCS may penetrate into living organisms and negatively affect the health of humans and animals. The majority of previous investigations on TCS biomonitoring in humans have been performed on urine, but currently, studies on hair samples are becoming increasingly important. The aim of this study was to evaluate TCS concentration levels in residents of Olsztyn, a city in northeastern Poland, using a liquid chromatography-mass spectrometry technique. The presence of TCS was observed in 96.7% of samples tested, with concentration levels from 37.9 pg/mg to 3386.5 pg/mg. The mean concentration level of TCS in the present study was 402.6 (±803.6) pg/mg, and the median value was 103.3 pg/mg. Although there were some differences in TCS concentration levels between males and females, humans of various ages and humans with colored and natural hair had no statistically significant differences in TCS concentration levels. The obtained results have clearly indicated that people living in northeastern Poland are exposed to TCS to a large degree, and hair analysis, despite some limitations, is a suitable method for TCS biomonitoring in humans.
Collapse
|
32
|
Liu M, Wu N, Tian B, Zhou D, Yan C, Huo Z, Qu R. Experimental and theoretical study on the degradation of Benzophenone-1 by Ferrate(VI): New insights into the oxidation mechanism. JOURNAL OF HAZARDOUS MATERIALS 2022; 425:127877. [PMID: 34883381 DOI: 10.1016/j.jhazmat.2021.127877] [Citation(s) in RCA: 15] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2021] [Revised: 11/11/2021] [Accepted: 11/19/2021] [Indexed: 06/13/2023]
Abstract
The oxidation of Benzophenone-1 (BP-1) by ferrate (Fe(VI)) was systemically investigated in this study. Neutral pH and high oxidant dose were favorable for the reaction, and the second order rate constant was 1.03 × 103 M-1·s-1 at pH = 7.0 and [Fe(VI)]0:[BP-1]0 = 10:1. The removal efficiency of BP-1 was enhanced by cations (K+, Ca2+, Mg2+, Cu2+, and Fe3+), while inhibited by high concentrations of anions (Cl- and HCO3-) and low concentrations of humic acid. Moreover, intermediates were identified by LC-MS, and five dominating reaction pathways were predicted, involving single hydroxylation, dioxygen transfer, bond breaking, polymerization and carboxylation. Theoretical calculations showed the dioxygen transfer could occur by Fe(VI) attacking the CC double-bond in benzene ring of BP-1 to form a five-membered ring intermediate, which was hydrolyzed twice followed by H-abstraction to generate the dihydroxy-added product directly from the parent compound. Dissolved CO2 or HCO3- might be fixed to produce carboxylated products, and Cl- led to the formation of two chlorinated products. In addition, the toxicity assessments showed the reaction reduced the environmental risk of BP-1. This work illustrates Fe(VI) could remove BP-1 in water environments efficiently, and the newly proposed dioxygen transfer mechanism herein may contribute to the development of Fe(VI) chemistry.
Collapse
Affiliation(s)
- Mingzhu Liu
- State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing 210023, Jiangsu, PR China
| | - Nannan Wu
- State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing 210023, Jiangsu, PR China
| | - Bingru Tian
- State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing 210023, Jiangsu, PR China
| | - Dongmei Zhou
- State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing 210023, Jiangsu, PR China
| | - Chao Yan
- School of the Life Sciences, Nanjing University, Nanjing 210023, Jiangsu, PR China
| | - Zongli Huo
- Jiangsu Provincial Center for Disease Control and Prevention, No. 172 Jiangsu Road, Nanjing 210023, Jiangsu, PR China
| | - Ruijuan Qu
- State Key Laboratory of Pollution Control and Resources Reuse, School of the Environment, Nanjing University, Nanjing 210023, Jiangsu, PR China.
| |
Collapse
|
33
|
Han M, Wang Y, Tang C, Fang H, Yang D, Wu J, Wang H, Chen Y, Jiang Q. Association of triclosan and triclocarban in urine with obesity risk in Chinese school children. ENVIRONMENT INTERNATIONAL 2021; 157:106846. [PMID: 34455189 DOI: 10.1016/j.envint.2021.106846] [Citation(s) in RCA: 28] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/29/2021] [Revised: 08/12/2021] [Accepted: 08/20/2021] [Indexed: 06/13/2023]
Abstract
BACKGROUND Laboratory studies have suggested that triclosan and triclocarban can influence energy metabolism by multiple mechanisms and are potential obesogens, but the effect on obesity risk has not been well investigated in human. OBJECTIVE To examine the associations of triclosan and triclocarban in urine with childhood obesity. METHODS We investigated 458 school children aged 7-11 years who entered a dynamic cohort of children established in Shanghai in 2019 and 2020. Triclosan and triclocarban were determined in first morning urine by liquid chromatography coupled to mass spectrometry. Body mass index (BMI) and waist circumference (WC) were used to identify general overweight/obesity and central obesity, respectively. Logistic regression and linear models of generalized estimating equations (GEE) were used to investigate the association between urinary triclosan and triclocarban with obesity prevalence. RESULTS After adjusting for potential confounders, children with detectable triclocarban in urine had a higher proportion of general overweight/obesity (odds ratio (OR): 1.84; 95% confidential interval (95% CI): 1.19, 2.85) or central obesity (OR: 1.71; 95% CI: 1.03, 2.84). Compared to the low tertile, children in the median tertile of triclosan showed a higher proportion of central obesity (OR: 1.78; 95 %CI: 0.98, 3.24) and children in the high tertile of triclocarban had a higher proportion of general overweight/obesity (OR: 2.25; 95 %CI: 1.31, 3.88) and central obesity (OR: 2.08; 95 %CI: 1.12, 3.87). When the tertiles of triclocarban in urine were treated as a continuous variable, a positive exposure-response relationship was found with general overweight/obesity (OR: 1.50; 95 %CI: 1.15, 1.96) and central obesity (OR: 1.44; 95 %CI: 1.06, 1.95). Multiple linear regression showed a positive exposure-response relationship between triclocarban and BMI (β: 0.45; 95 %CI: 0.11, 0.80) values. CONCLUSION Exposure to triclosan and triclocarban was associated with increased risk of childhood obesity. Given the cross-sectional design, more studies are needed to interrogate these findings.
Collapse
Affiliation(s)
- Minghui Han
- Key Laboratory of Public Health Safety of Ministry of Education/School of Public Health, Fudan University, Shanghai 200032, China
| | - Yuanping Wang
- Key Laboratory of Public Health Safety of Ministry of Education/School of Public Health, Fudan University, Shanghai 200032, China
| | - Chuanxi Tang
- Changning District Center for Disease Control and Prevention, Changning District, Shanghai 200051, China
| | - Hongji Fang
- Key Laboratory of Public Health Safety of Ministry of Education/School of Public Health, Fudan University, Shanghai 200032, China
| | - Dongjian Yang
- Key Laboratory of Public Health Safety of Ministry of Education/School of Public Health, Fudan University, Shanghai 200032, China
| | - Jingui Wu
- Changning District Center for Disease Control and Prevention, Changning District, Shanghai 200051, China
| | - Hexing Wang
- Key Laboratory of Public Health Safety of Ministry of Education/School of Public Health, Fudan University, Shanghai 200032, China.
| | - Yue Chen
- School of Epidemiology and Public Health, Faculty of Medicine, University of Ottawa, Ottawa, Ontario K1G 5Z3, Canada
| | - Qingwu Jiang
- Key Laboratory of Public Health Safety of Ministry of Education/School of Public Health, Fudan University, Shanghai 200032, China
| |
Collapse
|
34
|
Recent advances in analysis of bisphenols and their derivatives in biological matrices. Anal Bioanal Chem 2021; 414:807-846. [PMID: 34652496 DOI: 10.1007/s00216-021-03668-y] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2021] [Accepted: 09/14/2021] [Indexed: 10/20/2022]
Abstract
Biomonitoring is a very useful tool to evaluate human exposure to endocrine-disrupting compounds (EDCs), like bisphenols (BPs), which are widely used in the manufacture of plastics. The development of reliable analytical methods is key in the field of public health surveillance to obtain biomonitoring data to determine what BPs are reaching people's bodies. This review discusses recent methods for the quantitative measurement of bisphenols and their derivatives in biological samples like urine, blood, breast milk, saliva, and hair, among others. We also discuss the different procedures commonly used for sample treatment, which includes extraction and clean-up, and instrumental techniques currently used to determine these compounds. Sample preparation techniques continue to play an important role in the analysis of complex matrices, for liquid matrices the most commonly employed is solid-phase extraction, although microextraction techniques are gaining importance in this field, and for solid samples ultrasound-assisted extraction. The main instrumental techniques used are liquid and gas chromatography coupled with mass spectrometry. Finally, we present data on the main parameters obtained in the validation of the revised methods. This review focuses on various methods developed and applied for trace analysis of bisphenols, their conjugates, halogenated derivatives, and diglycidyl ethers in biological samples to enable the required selectivity and sensitivity. For this purpose, a review is carried out of the most recent relevant publications from 2016 up to present.
Collapse
|
35
|
Alampanos V, Kabir A, Furton K, Samanidou V. Magnet integrated fabric phase sorptive extraction of selected endocrine disrupting chemicals from human urine followed by high-performance liquid chromatography - photodiode array analysis. J Chromatogr A 2021; 1654:462459. [PMID: 34407470 DOI: 10.1016/j.chroma.2021.462459] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/30/2021] [Revised: 07/28/2021] [Accepted: 08/08/2021] [Indexed: 12/11/2022]
Abstract
In current paper, a new advanced modification of fabric phase sorptive extraction is introduced for the first time. This advantageous configuration that integrates the stirring and extraction mechanism into a single sample preparation device was originated by equally considering the beneficial role of the increase of extraction kinetics and more specifically of diffusion on the extraction efficiency of the equilibrium based microextraction techniques and the need for integrating and unite processes for better promotion and implementation of the principles of Green Analytical Chemistry. The resulted magnet integrated fabric phase sorptive extraction (MI-FPSE) device was the spearhead to develop a new analytical methodology for the determination of selected very common endocrine disrupting chemicals as model analytes in human urine by high-performance liquid chromatography-photodiode array analysis. More specifically, the sol-gel Carbowax 20 M coated on hydrophilic cellulose fabric substrate, MI-FPSE device was efficiently employed for the establishment of a new extraction protocol before the chromatographic determination. The sample preparation workflow was methodically optimized in terms of the elution solvent mixture, the volume of the sample, the extraction and the elution time, the stirring speed during the extraction, the ionic strength, and the pH of the sample matrix. The chromatographic separation was performed on a Spherisorb C18 column and a gradient elution program within 14 minutes. Mobile phase consisted of 0.05 ammonium acetate aqueous solution and acetonitrile. The method was validated towards linearity, sensitivity, selectivity, precision, accuracy, and stability. LOD and LOQ ranged between 1.05-1.80 and 3.5-6.0 ng/mL, while %RSD values were found lower than 9.0% in all cases. The method was efficiently applied to the bioanalysis of real samples. All the chosen EDCs were measured at high detection levels. The new MI-FPSE device has demonstrated its performance superiority as a magnet integrated stand-alone extraction device and could be considered as a significant improvement in the field of analytical/bioanalytical sample preparation.
Collapse
Affiliation(s)
- Vasileios Alampanos
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece
| | - Abuzar Kabir
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL, United States
| | - Kenneth Furton
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL, United States
| | - Victoria Samanidou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece.
| |
Collapse
|
36
|
Wang Y, Li G, Zhu Q, Liao C. Occurrence of parabens, triclosan and triclocarban in paired human urine and indoor dust from two typical cities in China and its implications for human exposure. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 786:147485. [PMID: 33975120 DOI: 10.1016/j.scitotenv.2021.147485] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/04/2021] [Revised: 04/28/2021] [Accepted: 04/28/2021] [Indexed: 05/05/2023]
Abstract
Parabens, triclosan (TCS) and triclocarban (TCC) are emerging endocrine disrupting chemicals, which are commonly used in personal care products and household applications in daily life. Due to their adverse health effects, human exposure to these chemicals has been a public concern. Despite evidence showing different exposure pathways of these chemicals, few studies have examined contribution of certain exposure to total human exposure. In this study, we measured six parabens, TCS and TCC in 129 indoor dust samples and these chemicals plus four paraben metabolites in 203 urine samples from two different cities in China (Suizhou, a typical small city in central China and Beijing, the capital of China). The median concentrations of ∑6Parabens (1050 ng/g) and ∑TCS + TCC (565 ng/g) in dusts from Beijing were 1.9-3.3 times higher than those from Suizhou (∑6Parabens: 314, ∑TCS + TCC: 294 ng/g). The ∑6Parabens in urines from Suizhou and Beijing were in the range of 0.208-645 and 0.455-2300 μg/g Creatinine (Cr), respectively. The ∑TCS + TCC concentrations in urine were 1-2 orders of magnitude lower than those found for ∑6Parabens. Comparatively, women had relatively higher body burden of parabens than men, which was more noticeable when considering the use of skin care products. In this regard, relatively higher levels of parabens were also found in women in couples. Positive correlations were found between concentrations of methyl-paraben (MeP) and ethyl-paraben (PrP) in paired dust and urine samples (p < 0.05). Human exposure to such chemicals was evaluated. Based on the measured concentrations in paired human urine and indoor dust samples, our results provided direct evidence that the contribution of indoor dust ingestion to the total exposure was minor. These findings are essential for clarifying the sources and potential exposure routes of these chemicals in humans.
Collapse
Affiliation(s)
- Yun Wang
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; College of Resources and Environment, University of Chinese Academy Sciences, Beijing 100049, China
| | - Guoliang Li
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Qingqing Zhu
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Chunyang Liao
- State Key Laboratory of Environmental Chemistry and Ecotoxicology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Institute of Environment and Health, Hangzhou Institute for Advanced Study, UCAS, Hangzhou, Zhejiang 310000, China; Institute of Environment and Health, Jianghan University, Wuhan, Hubei 430056, China; College of Resources and Environment, University of Chinese Academy Sciences, Beijing 100049, China.
| |
Collapse
|
37
|
Ao J, Zhang Q, Tang W, Yuan T, Zhang J. A simple, rapid and sensitive method for the simultaneous determination of eighteen environmental phenols in human urine. CHEMOSPHERE 2021; 278:130494. [PMID: 33845434 DOI: 10.1016/j.chemosphere.2021.130494] [Citation(s) in RCA: 23] [Impact Index Per Article: 5.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/29/2020] [Revised: 04/01/2021] [Accepted: 04/02/2021] [Indexed: 06/12/2023]
Abstract
Environmental phenols are a typical group of endocrine disrupting compounds (EDCs) and have caused growing concerns upon the potential adverse effects on humans. Urinary concentrations of phenols can be used as valid biomarkers for the assessment of human exposure. A method was developed for the simultaneous determination of eighteen environmental phenols (six parabens, seven bisphenols, four benzophenones and triclosan) in human urine using liquid-liquid extraction (LLE) coupled to high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS). The optimized LLE was time saving and required low volumes of organic solvents. A volume of only 0.2 mL urine sample was extracted and analyzed. The method yielded good linearity (0.9925-0.9994) and satisfactory limit of detection (LOD) (≤0.08 ng mL-1). The relative recoveries ranged between 76.7% and 116% at three spiked levels, with intra- and inter-day precision less than 8.04% and 13.5%, respectively. Our method has been proved to be simple, rapid and sensitive by a comprehensive comparison between methods. This proposed method provides a large-scale biomonitoring tool for exposure assessment of human population to environmental phenols.
Collapse
Affiliation(s)
- Junjie Ao
- Ministry of Education-Shanghai Key Laboratory of Children's Environmental Health, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200092, China
| | - Qianlong Zhang
- Ministry of Education-Shanghai Key Laboratory of Children's Environmental Health, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200092, China
| | - Weifeng Tang
- Ministry of Education-Shanghai Key Laboratory of Children's Environmental Health, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200092, China
| | - Tao Yuan
- School of Environmental Science and Engineering, Shanghai Jiao Tong University, Shanghai, 200240, China
| | - Jun Zhang
- Ministry of Education-Shanghai Key Laboratory of Children's Environmental Health, Xinhua Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, 200092, China.
| |
Collapse
|
38
|
Narloch I, Wejnerowska G. An Overview of the Analytical Methods for the Determination of Organic Ultraviolet Filters in Cosmetic Products and Human Samples. Molecules 2021; 26:4780. [PMID: 34443367 PMCID: PMC8400378 DOI: 10.3390/molecules26164780] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2021] [Revised: 07/29/2021] [Accepted: 08/03/2021] [Indexed: 12/29/2022] Open
Abstract
UV filters are a group of compounds commonly used in different cosmetic products to absorb UV radiation. They are classified into a variety of chemical groups, such as benzophenones, salicylates, benzotriazoles, cinnamates, p-aminobenzoates, triazines, camphor derivatives, etc. Different tests have shown that some of these chemicals are absorbed through the skin and metabolised or bioaccumulated. These processes can cause negative health effects, including mutagenic and cancerogenic ones. Due to the absence of official monitoring protocols, there is an increased number of analytical methods that enable the determination of those compounds in cosmetic samples to ensure user safety, as well as in biological fluids and tissues samples, to obtain more information regarding their behaviour in the human body. This review aimed to show and discuss the published studies concerning analytical methods for the determination of organic UV filters in cosmetic and biological samples. It focused on sample preparation, analytical techniques, and analytical performance (limit of detection, accuracy, and repeatability).
Collapse
Affiliation(s)
| | - Grażyna Wejnerowska
- Department of Food Analysis and Environmental Protection, Faculty of Chemical Technology and Engineering, UTP University of Science and Technology, 3 Seminaryjna Street, 85-326 Bydgoszcz, Poland;
| |
Collapse
|
39
|
Alampanos V, Kabir A, Furton KG, Samanidou V. Rapid exposure monitoring of six bisphenols and diethylstilbestrol in human urine using fabric phase sorptive extraction followed by high performance liquid chromatography - photodiode array analysis. J Chromatogr B Analyt Technol Biomed Life Sci 2021; 1177:122760. [PMID: 34052754 DOI: 10.1016/j.jchromb.2021.122760] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/15/2021] [Revised: 05/07/2021] [Accepted: 05/09/2021] [Indexed: 12/12/2022]
Abstract
A novel fabric phase sorptive extraction protocol is developed for rapid exposure monitoring of six bisphenol analogues, including bisphenol A, bisphenol S, bisphenol F, bisphenol E, bisphenol B, bisphenol C, and diethylstilbestrol (DES) from human urine prior to high-performance liquid chromatography-photodiode array analysis. FPSE sample pretreatment protocol ensures the harmonization of the proposed method with the principles of Green Analytical Chemistry (GAC). Among eighteen evaluated FPSE membranes, sol-gel poly (ethylene glycol) (PEG) coated cellulose FPSE membrane resulted in the most efficient extraction. This polar FPSE membrane effectively exploits a number of advantageous features inherent to FPSE including sponge-like porous architecture of the sol-gel sorbent coating, favorable surface chemistry, flexibility and built-in permeability of cellulose fabric substrate, high primary contact surface area for rapid sorbent-analyte interaction, expanded pH, solvent and thermal stability as well as reusability of the FPSE membrane. Optimization was centered on the evaluation of critical parameters, namely the size of the FPSE membrane, the elution solvent mixture, the volume of the sample, the extraction time, the elution time, the kind of the external agitation mechanical stimulus, the ionic strength and the pH of the sample. The chromatographic separation was achieved on a Spherisorb C18 column and a gradient elution program with mobile phase consisted of 0.05 ammonium acetate solution and acetonitrile. The total analysis time was 17.4 min. The developed method was validated in terms of linearity, sensitivity, selectivity, precision, accuracy, stability, and ruggedness. The limits of detection and quantification varied from 0.26-0.62 ng/mL and 0.8-1.9 ng/mL, respectively. The relative recoveries were calculated between 90.6 and 108.8%, while the RSD values were <10% in all cases. The effectiveness of the proposed method was confirmed by its successful implementation in the bioanalysis of real urine samples.
Collapse
Affiliation(s)
- V Alampanos
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece
| | - A Kabir
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| | - K G Furton
- Department of Chemistry and Biochemistry, Florida International University, Miami, FL, USA
| | - V Samanidou
- Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University of Thessaloniki, GR-54124 Thessaloniki, Greece.
| |
Collapse
|
40
|
Rozaini MNH, Saad B, Yahaya N, Lim JW, Mohd Aris MN, Ramachandran MR. Determination of Three Endocrine Disruptors in Water Samples by Ultrasound-Assisted Salt-Induced Liquid-Liquid Microextraction (UA-SI-LLME) and High-Performance Liquid Chromatography – Diode Array Detection (HPLC-DAD). ANAL LETT 2021. [DOI: 10.1080/00032719.2021.1919691] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Affiliation(s)
- Muhammad Nur’ Hafiz Rozaini
- Department of Fundamental and Applied Sciences, Universiti Teknologi PETRONAS, Perak Darul Ridzuan, Malaysia
| | - Bahruddin Saad
- Department of Fundamental and Applied Sciences, Universiti Teknologi PETRONAS, Perak Darul Ridzuan, Malaysia
| | - Noorfatimah Yahaya
- Integrative Medicine Cluster, Advanced Medical and Dental Institute (AMDI), Universiti Sains Malaysia, Penang, Malaysia
| | - Jun Wei Lim
- Department of Fundamental and Applied Sciences, Universiti Teknologi PETRONAS, Perak Darul Ridzuan, Malaysia
| | - Muhammad Naeim Mohd Aris
- Department of Fundamental and Applied Sciences, Universiti Teknologi PETRONAS, Perak Darul Ridzuan, Malaysia
| | | |
Collapse
|
41
|
Wu H, Dong S, Huang G, Zheng Q, Huang T. The extraction of four endocrine disrupters using hollow N-doped mesoporous carbon spheres with encapsulated magnetite (Fe3O4) nanoparticles coupled to HPLC-DAD determination. Microchem J 2021. [DOI: 10.1016/j.microc.2021.105984] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
42
|
Alampanos V, Samanidou V. An overview of sample preparation approaches prior to liquid chromatography methods for the determination of parabens in biological matrices. Microchem J 2021. [DOI: 10.1016/j.microc.2021.105995] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
43
|
Zhao F, Liu H, Li Z, Lin P, Wang A, Jin Y, Yi Y. Low-dose bisphenol A impairs the function of mouse decidual stromal cells by activating LUMAN-mediated unfolded protein response. Food Chem Toxicol 2021; 153:112242. [PMID: 33930482 DOI: 10.1016/j.fct.2021.112242] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/11/2020] [Revised: 03/30/2021] [Accepted: 04/22/2021] [Indexed: 11/15/2022]
Abstract
The nonsteroidal estrogenic compound bisphenol A (BPA) is widely present in several industrial and medical products including plastic food containers and sealants in dentistry. There are growing concerns on the toxic effects of this compounds since BPA is known to have reproductive toxicity. This study evaluated the effects of low-dose BPA exposure on decidual stromal cells (DSCs) of mice. The results showed that although 10 nM of BPA have no significant effect on the cell viability, it alters the expression of decidualization-related genes including Prl8a2, Prl3c1, Ptgs2, and Mmp2. Moreover, we found that low-dose BPA exposure induces UPR response in DSCs. However, the expression of the three major UPR receptors (Perk, Ire 1, and Xbp1) did not change significantly. Interestingly, the expression of Luman, a novel receptor of UPR, was significantly upregulated in a dose-dependent manner. Lentivirus containing shLuman sequence was used to generate stable Luman silencing DSCs. It's showed that Luman knockdown could affect the expression of decidualization-related genes in decidual cells after BPA treatment. In summary, these results suggest that Luman plays a key role in low dose BPA-induced decidual toxicity of DSCs in mouse.
Collapse
Affiliation(s)
- Fan Zhao
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, China; College of Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi, China; Key Laboratory of Animal Biotechnology of the Ministry of Agriculture, Northwest A&F University, Yangling, Shaanxi, China
| | - Huan Liu
- College of Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi, China; Key Laboratory of Animal Biotechnology of the Ministry of Agriculture, Northwest A&F University, Yangling, Shaanxi, China
| | - Zhanghuan Li
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, China
| | - Pengfei Lin
- College of Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi, China; Key Laboratory of Animal Biotechnology of the Ministry of Agriculture, Northwest A&F University, Yangling, Shaanxi, China
| | - Aihua Wang
- College of Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi, China; Key Laboratory of Animal Biotechnology of the Ministry of Agriculture, Northwest A&F University, Yangling, Shaanxi, China
| | - Yaping Jin
- College of Veterinary Medicine, Northwest A&F University, Yangling, Shaanxi, China; Key Laboratory of Animal Biotechnology of the Ministry of Agriculture, Northwest A&F University, Yangling, Shaanxi, China.
| | - Yanglei Yi
- College of Food Science and Engineering, Northwest A&F University, Yangling, Shaanxi, China.
| |
Collapse
|
44
|
Zhu H, Chinthakindi S, Kannan K. A method for the analysis of 121 multi-class environmental chemicals in urine by high-performance liquid chromatography-tandem mass spectrometry. J Chromatogr A 2021; 1646:462146. [PMID: 33895641 DOI: 10.1016/j.chroma.2021.462146] [Citation(s) in RCA: 26] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/09/2021] [Revised: 03/23/2021] [Accepted: 03/31/2021] [Indexed: 02/07/2023]
Abstract
Biomonitoring of human exposure to environmental chemicals has gained momentum in recent years. Biomonitoring methods often include analysis of a single class of chemicals with similar chemical properties. In this study, we describe a method that involves solid-phase extraction (SPE) coupled with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and capable of measuring 121 environmental chemicals comprising plasticizers (PMs; n = 45), environmental phenols (EPs; n = 45), and pesticides (n = 31) through a single extraction of urine. Urine samples were incubated with 20 µL of β-glucuronidase/arylsulfatase (4000 units/mL urine) (from Helix pomatia) buffered at pH 5.5 for 2 h at 37 °C for optimal deconjugation conditions. We compared two extraction methods, namely liquid-liquid extraction and SPE, and the latter with ABS Elut NEXUS® cartridges was optimized to yield best extraction efficiencies. For increased resolution and chromatographic separation, two methods involving Ultra AQ C18® and Betasil™ C18® columns were used. The MS/MS analyses were performed under both negative and positive ionization modes. The optimized method yielded excellent intra- and inter-day variabilities (relative standard deviation: 0.40-11%) and satisfactory recoveries (80-120%) for >95% of the analytes. The limits of detection were ≤ 0.1 ng/mL for 101 analytes and between 0.1 and 1.0 ng/mL for 18 analytes. The optimized SPE LC-MS/MS method was validated through the analysis of standard reference materials and proficiency test urine samples and further applied in the analysis of 21 real urine samples to demonstrate simultaneous determination of 121 environmental chemicals in urine samples.
Collapse
Affiliation(s)
- Hongkai Zhu
- Department of Pediatrics and Department of Environmental Medicine, New York University School of Medicine, MSB 6-698, 550 1st Avenue, New York, NY 10016, United States
| | - Sridhar Chinthakindi
- Department of Pediatrics and Department of Environmental Medicine, New York University School of Medicine, MSB 6-698, 550 1st Avenue, New York, NY 10016, United States
| | - Kurunthachalam Kannan
- Department of Pediatrics and Department of Environmental Medicine, New York University School of Medicine, MSB 6-698, 550 1st Avenue, New York, NY 10016, United States.
| |
Collapse
|
45
|
WEI J, QIN M, YANG J, YANG L. [Research progress of microextraction by packed sorbent and its application in microvolume sample extraction]. Se Pu 2021; 39:219-228. [PMID: 34227304 PMCID: PMC9403807 DOI: 10.3724/sp.j.1123.2020.04024] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2020] [Indexed: 11/30/2022] Open
Abstract
Microextraction is a rapidly developing sample preparation technology in the field of analytical chemistry, which is seeing widespread application. Accurate sample preparation can not only save time but also improve the efficiency of analysis, determination, and data quality. At present, sample pretreatment methods must be rapid, allow for miniaturization, automation, and convenient online connection with analytical instruments. To meet the requirements of green analytical methods and improve the extraction efficiency, microextraction techniques have been introduced as suitable replacements to conventional sample preparation and extraction methods. Microextraction using a packed sorbent (MEPS) is a new type of sample preparation technology. The MEPS equipment was prepared using microsyringe with a volume of 50-500 μL, including MEPS syringes and MEPS adsorption beds (barrel insert and needle, BIN), which is essentially similar to a miniaturized solid phase extraction device. The BIN contains the adsorbent and is built into the syringe needle. A typical MEPS extraction procedure involves repeatedly pumping the sample solution in two directions (up and down) through the adsorbent multiple times in the MEPS syringe. The specific operation course of MEPS includes conditioning, loading, washing, elution, and introduction into the analysis instrument. The conditioning process is adopted to infiltrate the dry sorbent and remove bubbles between the filler particles. The adsorption process is accomplished by pulling the liquid plunger of the syringe so that the sample flows through the adsorbent in both directions multiple times. The washing process involves rinsing the sorbent to remove unwanted components after the analyte is retained. The elution process involves the use of an eluent to ensure that the sample flows through the adsorbent in both directions multiple times, so that elution can be realized by the pumping-pushing action. The target analyte is eluted with the eluent, which can be directly used for chromatographic analysis. However, when processing complex biological matrix samples by MEPS, pretreatment steps such as dilution of the sample and removal of proteins are commonly required. At present, the operation modes of the MEPS equipment are classified into three types: manual, semi-automated, and fully automated. This increase in the degree of automation is highly conducive to processing extremely low or extremely high sample volumes. Critical factors affecting the MEPS performance have been investigated in this study. The conditions for MEPS optimization are the operating process parameters, including sample flow rate, sample volume, number of sample extraction cycles, type and volume of the adsorbent, and elution solvents. It is also necessary to consider the effect of the sample matrix on the performance of MEPS. The MEPS sorbent should be cleaned by a solvent to eliminate carryover and reuse. The sorbent is a core aspect of MEPS. Several types of commercial and non-commercial sorbents have been used in MEPS. Commercial sorbents include silica-based sorbents such as unmodified silica (SIL), C2, C8, and C18. Unmodified silicon-based silica is a normal phase adsorption material, which is highly polar and can be used to retain polar analytes. C18, C8, and C2 materials are suitable for reversed-phase adsorption, while SCX, SAX, APS, and M1 (C8+SCX) adsorbents are suitable for the mixed-mode and ion-exchange modes. Noncommercial sorbents include molecularly imprinted materials, restricted-access molecularly imprinted materials, graphitized carbon, conductive polymer materials, modified silicon materials, and covalent-organic framework materials. The performance of MEPS has recently been illustrated by online with LC-MS and GC-MS assays for the analysis of biological matrices, environmental samples, and food samples. Pretreatment in MEPS protocols includes dilution, protein precipitation, and centrifugation in biological fluid matrices. Because of the small sample size, fast operation, etc., MEPS is expected to be more widely used in the analysis of bio-matrix samples. MEPS devices could also play an important role in field pretreatment and analysis.
Collapse
Affiliation(s)
- Jianan WEI
- 国民核生化灾害防护国家重点实验室, 北京 102205
- State key Laboratory of Nuclear, Biological and Chemical Protection for Civilian, Beijing 102205, China
| | - Molin QIN
- 国民核生化灾害防护国家重点实验室, 北京 102205
- State key Laboratory of Nuclear, Biological and Chemical Protection for Civilian, Beijing 102205, China
| | - Junchao YANG
- 国民核生化灾害防护国家重点实验室, 北京 102205
- State key Laboratory of Nuclear, Biological and Chemical Protection for Civilian, Beijing 102205, China
| | - Liu YANG
- 国民核生化灾害防护国家重点实验室, 北京 102205
- State key Laboratory of Nuclear, Biological and Chemical Protection for Civilian, Beijing 102205, China
| |
Collapse
|
46
|
Yang P, Lin BG, Zhou B, Cao WC, Chen PP, Deng YL, Hou J, Sun SZ, Zheng TZ, Lu WQ, Cheng LM, Zeng WJ, Zeng Q. Sex-specific associations of prenatal exposure to bisphenol A and its alternatives with fetal growth parameters and gestational age. ENVIRONMENT INTERNATIONAL 2021; 146:106305. [PMID: 33395947 DOI: 10.1016/j.envint.2020.106305] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/16/2020] [Revised: 11/19/2020] [Accepted: 11/24/2020] [Indexed: 06/12/2023]
Abstract
BACKGROUND Bisphenol A (BPA) can cause detrimental effects on fetal growth. However, the effects of BPA alternatives, such as bisphenol F (BPF) and bisphenol S (BPS), on fetal growth are less known. OBJECTIVE To investigate the relationships of prenatal BPA, BPF, and BPS exposures with fetal growth parameters and gestational age. METHODS Urinary BPA, BPF, and BPS were measured in 1,197 pregnant women before delivery in a Chinese cohort. The associations of prenatal exposure to BPA, BPF, and BPS with fetal growth parameters and gestational age were examined, and associations stratified by fetal sex were also conducted. We used a restricted cubic splines (RCS) model to examine the dose-response associations between exposures and outcomes. RESULTS Maternal urinary BPA and BPF were negatively related to birth length (-0.30 cm, 95% CI: -0.44, -0.15 and -0.21 cm, 95% CI: -0.36, -0.07 comparing the extreme exposure groups, respectively, both p for trends < 0.01). These associations were more pronounced in girls with inverted U-shaped dose-response relationships. Maternal urinary BPA and BPF were positively related to ponderal index (0.05 g/cm3 × 100, 95% CI: 0.01, 0.09 and 0.04 g/cm3 × 100, 95% CI: 0.01, 0.08 comparing the extreme exposure groups, respectively, both p for trends = 0.02), and maternal urinary BPS was associated with shorter gestational age (-0.20 weeks, 95% CI: -0.37, -0.03 comparing the extreme exposure groups, p for trend = 0.02). These associations were only observed in girls and exhibited a linear dose-response relationship. CONCLUSIONS Prenatal BPA, BPF, and BPS exposures were associated with detrimental effects on fetal growth parameters, and stronger effects were noted in female infants.
Collapse
Affiliation(s)
- Pan Yang
- Department of Occupational and Environmental Health, and Key Laboratory of Environment and Health, Ministry of Education & Ministry of Environmental Protection, and State Key Laboratory of Environmental Health (incubating), School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, PR China; Department of Occupational and Environmental Health, School of Basic Medicine and Public Health, Jinan University, Guangzhou, PR China
| | - Bi-Gui Lin
- State Environmental Protection Key Laboratory of Environmental Pollution Health Risk Assessment, South China Institute of Environmental Sciences, Ministry of Environmental Protection, Guangzhou 510655, China
| | - Bin Zhou
- Wuhan Children's Hospital (Wuhan Maternal and Child Healthcare Hospital), Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, PR China
| | - Wen-Cheng Cao
- Hubei Provincial Key Laboratory for Applied Toxicology, Hubei Provincial Center for Disease Control and Prevention, Wuhan, Hubei, PR China
| | - Pan-Pan Chen
- Department of Occupational and Environmental Health, and Key Laboratory of Environment and Health, Ministry of Education & Ministry of Environmental Protection, and State Key Laboratory of Environmental Health (incubating), School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, PR China
| | - Yan-Ling Deng
- Department of Occupational and Environmental Health, and Key Laboratory of Environment and Health, Ministry of Education & Ministry of Environmental Protection, and State Key Laboratory of Environmental Health (incubating), School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, PR China
| | - Jian Hou
- Department of Epidemiology and Biostatistics, College of Public Health, Zhengzhou University, Zhengzhou, Henan, PR China
| | - Sheng-Zhi Sun
- Department of Environmental Health, Boston University School of Public Health, Boston, MA, USA
| | - Tong-Zhang Zheng
- Department of Epidemiology, Brown University School of Public Health, Providence, RI, USA
| | - Wen-Qing Lu
- Department of Occupational and Environmental Health, and Key Laboratory of Environment and Health, Ministry of Education & Ministry of Environmental Protection, and State Key Laboratory of Environmental Health (incubating), School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, PR China
| | - Li-Ming Cheng
- Department of Laboratory Medicine, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, PR China
| | - Wan-Jiang Zeng
- Department of Obstetrics and Gynecology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, PR China
| | - Qiang Zeng
- Department of Occupational and Environmental Health, and Key Laboratory of Environment and Health, Ministry of Education & Ministry of Environmental Protection, and State Key Laboratory of Environmental Health (incubating), School of Public Health, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, Hubei, PR China; Department of Epidemiology, Brown University School of Public Health, Providence, RI, USA.
| |
Collapse
|
47
|
Bocato MZ, Cesila CA, Lataro BF, de Oliveira ARM, Campíglia AD, Barbosa F. A fast-multiclass method for the determination of 21 endocrine disruptors in human urine by using vortex-assisted dispersive liquid-liquid microextraction (VADLLME) and LC-MS/MS. ENVIRONMENTAL RESEARCH 2020; 189:109883. [PMID: 32678735 DOI: 10.1016/j.envres.2020.109883] [Citation(s) in RCA: 24] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/10/2020] [Revised: 06/27/2020] [Accepted: 06/28/2020] [Indexed: 06/11/2023]
Abstract
Simplicity, speed, and reduced cost are essential demands for routine analysis in human biomonitoring studies. Moreover, the availability of higher volumes of human specimens is becoming more restrictive due to ethical controls and to the costs associated with sample transportation and storage. Thus, analytical methods requiring much lower sample volumes associated with simultaneous detection capability (multiclass analysis) are with a very high claim. In this sense, the present approach aimed at the development of a method for preconcentration and simultaneous determination of four classes of endocrine disruptors (seven bisphenols, seven parabens, five benzophenones, and two antimicrobials) in the urine. The approach is based on vortex-assisted dispersive liquid-liquid microextraction (VADLLME) and high-performance liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). After optimization of the significant parameters of VADLLME extraction, the proposed procedure showed to be simple, fast, sensitive, requiring only 1.0 mL of urine, 400 μL of organic solvents with a total stirring time of 20 s. Moreover, a variation of inter-day and between-day runs were lower than 10.0% and 11.0%, respectively. Finally, the proposed method was successfully applied to the analysis of 50 urine samples of Brazilian pregnant women to establish reference ranges.
Collapse
Affiliation(s)
- Mariana Zuccherato Bocato
- Departamento de Análises Clínicas, Toxicológicas e Bromatológicas, Faculdade de Ciências Farmacêuticas de Ribeirão Preto, Universidade de São Paulo, 14040-903, Ribeirão Preto, SP, Brazil
| | - Cibele Aparecida Cesila
- Departamento de Análises Clínicas, Toxicológicas e Bromatológicas, Faculdade de Ciências Farmacêuticas de Ribeirão Preto, Universidade de São Paulo, 14040-903, Ribeirão Preto, SP, Brazil
| | - Beatriz Favero Lataro
- Faculdade de Ciências Farmacêuticas, Universidade de Ribeirão Preto, 14096-900, Ribeirão Preto, SP, Brazil
| | - Anderson Rodrigo Moraes de Oliveira
- Departamento de Química, Faculdade de Filosofia, Ciências e Letras de Ribeirão Preto, Universidade de São Paulo, 14040-901, Ribeirão Preto, SP, Brazil; National Institute for Alternative Technologies of Detection, Toxicological Evaluation and Removal of Micropollutants and Radioactives (INCT-DATREM), Unesp, Institute of Chemistry, 14800-900, Araraquara, SP, Brazil
| | - Andres Dobal Campíglia
- Department of Chemistry, University of Central Florida, P.O.Box 25000, 32816, Orlando, FL, USA
| | - Fernando Barbosa
- Departamento de Análises Clínicas, Toxicológicas e Bromatológicas, Faculdade de Ciências Farmacêuticas de Ribeirão Preto, Universidade de São Paulo, 14040-903, Ribeirão Preto, SP, Brazil.
| |
Collapse
|
48
|
Freitas JM, Wachter N, Rocha-Filho RC. Determination of bisphenol S, simultaneously to bisphenol A in different water matrices or solely in electrolyzed solutions, using a cathodically pretreated boron-doped diamond electrode. Talanta 2020; 217:121041. [DOI: 10.1016/j.talanta.2020.121041] [Citation(s) in RCA: 16] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2020] [Revised: 04/10/2020] [Accepted: 04/13/2020] [Indexed: 12/13/2022]
|
49
|
A green - high throughput –extraction method based on hydrophobic natural deep eutectic solvent for the determination of emerging contaminants in water by high performance liquid chromatography – diode array detection. J Chromatogr A 2020; 1626:461377. [DOI: 10.1016/j.chroma.2020.461377] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 06/16/2020] [Accepted: 06/28/2020] [Indexed: 11/18/2022]
|
50
|
Khoshmaram L, Saadati M, Karimi A. A simple and rapid technique for the determination of copper based on air-assisted liquid-liquid microextraction and image colorimetric analysis. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2020; 12:3490-3498. [PMID: 32672284 DOI: 10.1039/d0ay00706d] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
In this study, a new, cheap, simple and rapid method for the determination of copper in water and food samples using air-assisted liquid-liquid microextraction and digital image decomposition into the primary colors Red (R), Green (G) and Blue (B) is introduced. In the proposed method, sodium diethyl-dithiocarbamate (Na-DDTC) and carbon tetrachloride (CCl4) were used as the chelating agent and extraction solvent, respectively. The digital images of the extraction phase were obtained using an Android mobile phone and analyzed using a free app (Color Grab). Then the value of the B channel was taken as the analytical signal. The effects of different parameters influencing the extraction efficiency were investigated and optimized. Under the optimal conditions, the limit of detection (LOD) and quantitation (LOQ) were 1.5 and 5 μg L-1, respectively. The repeatability of the proposed method, expressed as the relative standard deviation (RSD), was 4.53% for intra-day (n = 8, C = 100 μg L-1) and 5.66% for inter-day (n = 5) precision. The proposed method was applied for the determination of trace amounts of copper in rice, lettuce and water samples with satisfactory results validated by the Graphite Furnace Atomic Absorption Spectrometry technique.
Collapse
Affiliation(s)
- Leila Khoshmaram
- Department of Chemistry, Faculty of Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran.
| | - Masoud Saadati
- Department of Science, Farhangian University, Tabriz, Iran
| | - Ali Karimi
- Department of Chemistry, Faculty of Sciences, Azarbaijan Shahid Madani University, Tabriz, Iran.
| |
Collapse
|