1
|
Li H, Liu J, Li C, Wang R, Kannan S, Li X, Fu G. Development of a syringe-hosted load-and-read immunoassay device using autoinjected distance readout in paper inserts. Mikrochim Acta 2025; 192:195. [PMID: 40016539 DOI: 10.1007/s00604-025-07052-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/08/2025] [Accepted: 02/15/2025] [Indexed: 03/01/2025]
Abstract
Pressure-based signal readout is promising for developing instrument-free immunoassays, but new detection methods are desirable to further advance the applicability of point-of-care testing (POCT). Herein, we developed a syringe-hosted load-and-read immunoassay device using autoinjected distance readout in paper inserts. The device was composed of multiple disposable syringes as the host for immuno-recognition, a three-dimensional (3D)-printed loading magazine of the syringes, and paper inserts to the magazine for distance signal readout. Using prostate-specific antigen (PSA) as a model target, the immuno-recognition system was constructed on the inner cylinder walls of the syringes. The immuno-captured platinum nanoparticles (Pt NPs) catalyzed the decomposition of H2O2 to produce O2 in the cylinders, driving the automatic quantitative injection behavior of the syringes. By loading the syringes into the magazine, the autoinjected liquids were received by the paper inserts to display the immunoassay signals as a visual traveling distance of liquids. PSA was determined with a low limit of detection (LOD) of 0.32 ng/mL and high accuracy in testing clinical serum specimens. Given the advantages of the simple syringe-hosted immuno-recognition method and the load-and-read signal readout in the paper inserts, the immunoassay device shows great potential in POCT.
Collapse
Affiliation(s)
- Haojie Li
- School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation, Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong ,Yantai University, Yantai, Shandong, 264005, China
| | - Jie Liu
- Department of Clinical Laboratory, Affiliated Yantai Yuhuangding Hospital of Qingdao University, Yantai, Shandong, 264000, China
| | - Cuili Li
- School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation, Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong ,Yantai University, Yantai, Shandong, 264005, China
| | - Runze Wang
- School of Electromechanical and Automotive Engineering, Yantai University, Yantai, Shandong, 264005, China
| | - Sapna Kannan
- Department of Chemistry and Biochemistry, Border Biomedical Research Center, Forensic Science, & Environmental Science and Engineering, University of Texas at El Paso, El Paso, TX, 79968, USA
| | - XiuJun Li
- Department of Chemistry and Biochemistry, Border Biomedical Research Center, Forensic Science, & Environmental Science and Engineering, University of Texas at El Paso, El Paso, TX, 79968, USA.
| | - Guanglei Fu
- School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation, Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong ,Yantai University, Yantai, Shandong, 264005, China.
| |
Collapse
|
2
|
Nam NN, Trinh TND, Do HDK, Phan TB, Trinh KTL, Lee NY. Advances and Opportunities of luminescence Nanomaterial for bioanalysis and diagnostics. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 327:125347. [PMID: 39486236 DOI: 10.1016/j.saa.2024.125347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/06/2023] [Revised: 04/15/2024] [Accepted: 10/24/2024] [Indexed: 11/04/2024]
Abstract
Luminescence nanomaterials (LNMs) have recently received great attention in biological analysis and sensing owing to their key advances in easy design and functionalization with high photostability, luminescence stability, low autofluorescence, and multiphoton capacity. The number of publications surrounding LNMs for biological applications has grown rapidly. LNMs based on Stokes and anti-Stokes shifts are powerful tools for biological analysis. Especially, unique properties of anti-Stokes luminescence such as upconversion nanoparticles (UCNPs) with an implementation strategy to use longer-wavelength excitation sources such as near-infrared (NIR) light can depth penetrate to biological tissue for bioanalysis and bioimaging. We observed that the LNMs-based metal-organic frameworks (MOFs) have been developed and paid attention to the field of bioimaging and luminescence-based sensors, because of their structural flexibility, and multifunctionality for the encapsulation of luminophores. This article provides an overview of innovative LNMs such as quantum dots (QDs), UCNPs, and LMOFs. A brief summary of recent progress in design strategies and applications of LNMs including pH and temperature sensing in biologically responsive platforms, pathogen detection, molecular diagnosis, bioimaging, photodynamic, and radiation therapy published within the past three years is highlighted. It was found that the integrated nanosystem of lab-on-a-chip (LOC) with nanomaterials was rapidly widespread and erupting in interest after the COVID-19 pandemic. The simple operation and close processes of the integration nanosystem together with the optimized size and low energy and materials consumption of biochips and devices allow their trend study and application to develop portable and intelligent diagnostics tools. The last part of this work is the introduction of the utilization use of LNMs in LOC applications in terms of microfluidics and biodevices.
Collapse
Affiliation(s)
- Nguyen Nhat Nam
- Biotechnology Center, School of Agriculture and Aquaculture, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Thi Ngoc Diep Trinh
- Department of Materials Science, School of Applied Chemistry, Tra Vinh University, Tra Vinh City 87000, Vietnam
| | - Hoang Dang Khoa Do
- NTT Hi-Tech Institute, Nguyen Tat Thanh University, Ho Chi Minh City 72820, Vietnam
| | - Thang Bach Phan
- Center for Innovative Materials and Architectures (INOMAR), Ho Chi Minh City 72820, VietNam; Vietnam National University, Ho Chi Minh City 72820, VietNam
| | - Kieu The Loan Trinh
- BioNano Applications Research Center, Gachon University 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| | - Nae Yoon Lee
- Department of BioNano Technology, Gachon University 1342 Seongnam-daero, Sujeong-gu, Seongnam-si, Gyeonggi-do, 13120, South Korea.
| |
Collapse
|
3
|
Ming W, Zhu Y, Jiang W, Zhang J, Liu J, Wu L, Qin Y. Advanced point-of-care biomarker testing for the diagnosis of cardiovascular diseases. SENSING AND BIO-SENSING RESEARCH 2025; 47:100747. [DOI: 10.1016/j.sbsr.2025.100747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/03/2025] Open
|
4
|
Huang H, Li Y, Wu Y, Zhao X, Gao H, Xie X, Wu L, Zhao H, Li L, Zhang J, Chen M, Wu Q. Advances in Helicobacter pylori detection technology: From pathology-based to multi-omic based methods. Trends Analyt Chem 2025; 182:118041. [DOI: 10.1016/j.trac.2024.118041] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/06/2025]
|
5
|
Li C, Liu J, Almanza A, Li X, Fu G. Integration of Immunosyringe Sensors with Bar-Chart Chips for Prick-and-Read Testing of Prostate Specific Antigen. Anal Chem 2024; 96:20267-20276. [PMID: 39654363 DOI: 10.1021/acs.analchem.4c04822] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2024]
Abstract
Pressure-based signal transduction is of promise in developing microfluidic immunoassays such as volumetric bar-chart chips (V-chips), but new working principles are required to further simplify the methods in point-of-care testing (POCT). Herein, we developed immunosyringe sensors and integrated them with bar-chart chips for simple prick-and-read testing of prostate specific antigen (PSA) as a model target. Disposable syringes served as the host for the construction of the sandwich-type immuno-recognition system. Platinum nanoparticles (Pt NPs) as the peroxidase-mimicking detection probe catalyzed the decomposition of H2O2 to produce O2 in the syringe cylinders, enabling the pressure-driven automatic injection of liquids from the syringes. The immuno-recognition event in the syringes was thereby converted into the quantitative autoinjection behavior of the syringes, namely, immunosyringe sensors. By simply pricking the sensors to bar-chart chips, we visually and quantitatively read the immunoassay signals as the bar-chart injection distance of liquids from the syringes in channels of the chips. The immunoassay showed a limit of detection (LOD) of 0.41 ng/mL in PSA detection with satisfactory accuracy in testing clinical serum samples. Owing to the integration with the immunosyringe sensors, this method, in comparison with conventional V-chips, works in a simpler prick-and-read manner without complex chip configurations and specialized chip operations (e.g., on-chip loading of microvolume reagents and sealing treatments). Therefore, the immunoassay shows great potential in POCT applications.
Collapse
Affiliation(s)
- Cuili Li
- School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation, Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Yantai University, Yantai, Shandong 264005, China
| | - Jie Liu
- Department of Clinical Laboratory, Affiliated Yantai Yuhuangding Hospital of Qingdao University, Yantai, Shandong 264000, China
| | - Ariana Almanza
- Department of Chemistry and Biochemistry, Border Biomedical Research Center, Forensic Science, & Environmental Science and Engineering, University of Texas at El Paso, El Paso, Texas 79968, United States
| | - XiuJun Li
- Department of Chemistry and Biochemistry, Border Biomedical Research Center, Forensic Science, & Environmental Science and Engineering, University of Texas at El Paso, El Paso, Texas 79968, United States
| | - Guanglei Fu
- School of Pharmacy, Key Laboratory of Molecular Pharmacology and Drug Evaluation, Ministry of Education, Collaborative Innovation Center of Advanced Drug Delivery System and Biotech Drugs in Universities of Shandong, Yantai University, Yantai, Shandong 264005, China
| |
Collapse
|
6
|
Feng W, Wen Y, Sun S, Li P, Shi S. Reconfigurable All-Oil Microfluidic Devices by 3D Printing. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2024; 20:e2405892. [PMID: 39113653 DOI: 10.1002/smll.202405892] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/25/2024] [Revised: 08/01/2024] [Indexed: 10/04/2024]
Abstract
Nanoparticle surfactants have been widely used to construct structured liquids in oil-water systems. Less attention, though, has been given in non-aqueous systems, for example, oil-oil systems, mainly due to the lack of suitable surfactants. Here, by using newly developed molecular brush surfactants (MBSs) that form at the DMSO-silicone oil interface, the construction of all-oil microfluidic devices is reported with advanced functions. Due to the high interfacial activity of MBSs, Plateau-Rayleigh instabilities of liquid jets can be completely suppressed, leading to the production of liquid threads with jammed MBSs at the interface. Taking advantage of the 3D printing technique, all-oil microfluidic devices with complex structures can be constructed, showing promising applications in mass transmission, chemical separation, and material synthesis.
Collapse
Affiliation(s)
- Weixiao Feng
- State Key Laboratory of Chemical Resource Engineering, Beijing Advanced Innovation Center for Soft Matter Science and Engineering, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Yunhui Wen
- State Key Laboratory of Chemical Resource Engineering, Beijing Advanced Innovation Center for Soft Matter Science and Engineering, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Shuyi Sun
- State Key Laboratory of Chemical Resource Engineering, Beijing Advanced Innovation Center for Soft Matter Science and Engineering, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Peifan Li
- State Key Laboratory of Chemical Resource Engineering, Beijing Advanced Innovation Center for Soft Matter Science and Engineering, Beijing University of Chemical Technology, Beijing, 100029, China
| | - Shaowei Shi
- State Key Laboratory of Chemical Resource Engineering, Beijing Advanced Innovation Center for Soft Matter Science and Engineering, Beijing University of Chemical Technology, Beijing, 100029, China
| |
Collapse
|
7
|
Zhang T, Dong X, Gao X, Yang Y, Song W, Song J, Bi H, Guo Y, Song J. Applications of Metals and Metal Compounds in Improving the Sensitivity of Microfluidic Biosensors - A Review. Chemistry 2024; 30:e202400578. [PMID: 38801721 DOI: 10.1002/chem.202400578] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/26/2024] [Revised: 05/09/2024] [Accepted: 05/27/2024] [Indexed: 05/29/2024]
Abstract
The enhancement of detection sensitivity in microfluidic sensors has been a continuously explored field. Initially, many strategies for sensitivity improvement involved introducing enzyme cascade reactions, but enzyme-based reactions posed challenges in terms of cost, stability, and storage. Therefore, there is an urgent need to explore enzyme-free cascade amplification methods, which are crucial for expanding the application range and improving detection stability. Metal or metal compound nanomaterials have gained great attention in the exploitation of microfluidic sensors due to their ease of preparation, storage, and lower cost. The unique physical properties of metallic nanomaterials, including surface plasmon resonance, surface-enhanced Raman scattering, metal-enhanced fluorescence, and surface-enhanced infrared absorption, contribute significantly to enhancing detection capabilities. The metal-based catalytic nanomaterials, exemplified by Fe3O4 nanoparticles and metal-organic frameworks, are considered viable alternatives to biological enzymes due to their excellent performance. Herein, we provide a detailed overview of the applications of metals and metal compounds in improving the sensitivity of microfluidic biosensors. This review not only highlights the current developments but also critically analyzes the challenges encountered in this field. Furthermore, it outlines potential directions for future research, contributing to the ongoing development of microfluidic biosensors with improved detection sensitivity.
Collapse
Affiliation(s)
- Taiyi Zhang
- College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan, 250200, China
- State Key Laboratory of Biobased Material and Green Papermaking, School of Bioengineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, China
| | - Xuezhen Dong
- College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan, 250200, China
| | - Xing Gao
- College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan, 250200, China
| | - Yujing Yang
- State Key Laboratory of Biobased Material and Green Papermaking, School of Bioengineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, China
| | - Weidu Song
- State Key Laboratory of Biobased Material and Green Papermaking, School of Bioengineering, Qilu University of Technology, Shandong Academy of Sciences, Jinan, 250353, China
| | - Jike Song
- School of Ophthalmology and Optometry, Shandong University of Traditional Chinese Medicine, Jinan, 250353, China
| | - Hongsheng Bi
- Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine, Jinan, 250002, China
| | - Yurong Guo
- College of Biological and Chemical Engineering, Qilu Institute of Technology, Jinan, 250200, China
| | - Jibin Song
- State Key Laboratory of Chemical Resource Engineering, College of Chemistry, Beijing University of Chemical Technology, Beijing, 10010, P. R. China
| |
Collapse
|
8
|
Ly NH, Aminabhavi TM, Vasseghian Y, Joo SW. Advanced protein nanobiosensors to in-situ detect hazardous material in the environment. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2024; 366:121727. [PMID: 39008923 DOI: 10.1016/j.jenvman.2024.121727] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/23/2024] [Revised: 07/01/2024] [Accepted: 07/02/2024] [Indexed: 07/17/2024]
Abstract
Determining hazardous substances in the environment is vital to maintaining the safety and health of all components of society, including the ecosystem and humans. Recently, protein-based nanobiosensors have emerged as effective tools for monitoring potentially hazardous substances in situ. Nanobiosensor detection mode is a combination of particular plasmonic nanomaterials (e.g., nanoparticles, nanotubes, quantum dots, etc.), and specific bioreceptors (e.g., aptamers, antibodies, DNA, etc.), which has the benefits of high selectivity, sensitivity, and compatibility with biological systems. The role of these nanobiosensors in identifying dangerous substances (e.g., heavy metals, organic pollutants, pathogens, toxins, etc.) is discussed along with different detection mechanisms and various transduction methods (e.g., electrical, optical, mechanical, electrochemical, etc.). In addition, topics discussed include the design and construction of these sensors, the selection of proteins, the integration of nanoparticles, and their development processes. A discussion of the challenges and prospects of this technology is also included. As a result, protein nanobiosensors are introduced as a powerful tool for monitoring and improving environmental quality and community safety.
Collapse
Affiliation(s)
- Nguyen Hoang Ly
- Department of Chemistry, Gachon University, Seongnam, 13120, South Korea
| | - Tejraj M Aminabhavi
- Center for Energy and Environment, School of Advanced Sciences, KLE Technological University, Hubballi, Karnataka, 580 031, India; Korea University, Seoul, South Korea; School of Engineering, University of Petroleum and Energy Studies (UPES) Uttarakhand, Dehradun, 248 007, India.
| | - Yasser Vasseghian
- Department of Chemistry, Soongsil University, Seoul, 06978, South Korea; Centre for Herbal Pharmacology and Environmental Sustainability, Chettinad Hospital and Research Institute, Chettinad Academy of Research and Education, Kelambakkam, 603103, Tamil Nadu, India.
| | - Sang-Woo Joo
- Department of Chemistry, Soongsil University, Seoul, 06978, South Korea.
| |
Collapse
|
9
|
Matsui K, Katsumata H, Furukawa M, Tateishi I, Kaneco S. Determination of low concentrations of glucose through colorimetric analysis using CoFe 2O 4 magnetic catalyst and SAT-3. ANAL SCI 2024; 40:1249-1260. [PMID: 38602663 DOI: 10.1007/s44211-024-00554-2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2024] [Accepted: 03/04/2024] [Indexed: 04/12/2024]
Abstract
Natural enzyme mimics have attracted attention as alternatives to natural peroxidases. Among these, magnetic nanoparticles, especially ferrites, have attracted attention because of their unique electronic and physical structures, which are expected to be applied in various fields, including high-frequency magnetic materials, biomaterials, gas sensors, and semiconductor photocatalysts. The structural properties of the synthesized catalysts were investigated using X-ray diffraction, X-ray photoelectron spectroscopy, scanning electron microscopy, and transmission electron microscopy. The prepared CoFe2O4 exhibited a spinel ferrite structure and formed a wood-flake-like bulk structure. In this study, magnetic CoFe2O4 was prepared using a precipitation method as a natural enzyme mimetic. CoFe2O4 showed excellent peroxidase-like activity, as demonstrated by the Michaelis-Menten constant (Km) and the maximum velocity (Vmax). The linear ranges of the calibration curves for H2O2 and glucose were in the range of 0-500 µM, and the detection limits were 1.83 and 5.91 µM, respectively. This analytical method was applied for the determination of glucose in human serum, and the results were satisfactory and consistent with certified values. The performance of this sensor was comparable to or superior to those of several other sensors commonly used for glucose analysis, indicating that its practical application is feasible.
Collapse
Affiliation(s)
- Kurumi Matsui
- Department of Applied Chemistry, Graduate School of Engineering, Mie University, Tsu, Mie, 514-8507, Japan.
| | - Hideyuki Katsumata
- Department of Applied Chemistry, Graduate School of Engineering, Mie University, Tsu, Mie, 514-8507, Japan.
| | - Mai Furukawa
- Department of Applied Chemistry, Graduate School of Engineering, Mie University, Tsu, Mie, 514-8507, Japan
| | - Ikki Tateishi
- Global Environmental Center for Education & Research, Mie University, Tsu, Mie, 514-8507, Japan
| | - Satoshi Kaneco
- Department of Applied Chemistry, Graduate School of Engineering, Mie University, Tsu, Mie, 514-8507, Japan
| |
Collapse
|
10
|
Yuan L, Gao X, Kang R, Zhang X, Meng X, Li X, Li X. Flexible Strain Sensors Based on an Interlayer Synergistic Effect of Nanomaterials for Continuous and Noninvasive Blood Pressure Monitoring. ACS APPLIED MATERIALS & INTERFACES 2024; 16:26943-26953. [PMID: 38718354 DOI: 10.1021/acsami.4c04134] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/24/2024]
Abstract
The continuous, noninvasive monitoring of human blood pressure (BP) through the accurate detection of pulse waves has extremely stringent requirements on the sensitivity and stability of flexible strain sensors. In this study, a new ultrasensitive flexible strain sensor based on the interlayer synergistic effect was fabricated through drop-casting and drying silver nanowires and graphene films on polydimethylsiloxane substrates and was further successfully applied for continuous monitoring of BP. This strain sensor exhibited ultrahigh sensitivity with a maximum gauge factor of 34357.2 (∼700% sensitivity enhancement over other major sensors), satisfactory response time (∼85 ms), wide strange range (12%), and excellent stability. An interlayer fracture mechanism was proposed to elucidate the working principle of the strain sensor. The real-time BP values can be obtained by analyzing the relationship between the BP and the pulse transit time. To verify our strain sensor for real-time BP monitoring, our strain sensor was compared with a conventional electrocardiogram-photoplethysmograph method and a commercial cuff-based device and showed similar measurement results to BP values from both methods, with only minor differences of 0.693, 0.073, and 0.566 mmHg in the systolic BP, diastolic BP, and mean arterial pressure, respectively. Furthermore, the reliability of the strain sensors was validated by testing 20 human subjects for more than 50 min. This ultrasensitive strain sensor provides a new pathway for continuous and noninvasive BP monitoring.
Collapse
Affiliation(s)
- Lin Yuan
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
| | - Xiaoguang Gao
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
- The Key Laboratory of Weak Light Nonlinear Photonics, Ministry of Education, Nankai University, Tianjin 300071, China
| | - Ranran Kang
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
| | - Xiaoliang Zhang
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
| | - Xuejuan Meng
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
| | - Xiaochun Li
- College of Biomedical Engineering, Taiyuan University of Technology, Taiyuan 030024, China
| | - Xiujun Li
- Department of Chemistry and Biochemistry, Forensic Science, & Environmental Science & Engineering, University of Texas at El Paso, 500 W University Ave, El Paso, Texas 79968, United States
| |
Collapse
|
11
|
Dhahi TS, Dafhalla AKY, Saad SA, Zayan DMI, Ahmed AET, Elobaid ME, Adam T, Gopinath SCB. The importance, benefits, and future of nanobiosensors for infectious diseases. Biotechnol Appl Biochem 2024; 71:429-445. [PMID: 38238920 DOI: 10.1002/bab.2550] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/08/2023] [Accepted: 12/19/2023] [Indexed: 04/11/2024]
Abstract
Infectious diseases, caused by pathogenic microorganisms such as bacteria, viruses, parasites, or fungi, are crucial for efficient disease management, reducing morbidity and mortality rates and controlling disease spread. Traditional laboratory-based diagnostic methods face challenges such as high costs, time consumption, and a lack of trained personnel in resource-poor settings. Diagnostic biosensors have gained momentum as a potential solution, offering advantages such as low cost, high sensitivity, ease of use, and portability. Nanobiosensors are a promising tool for detecting and diagnosing infectious diseases such as coronavirus disease, human immunodeficiency virus, and hepatitis. These sensors use nanostructured carbon nanotubes, graphene, and nanoparticles to detect specific biomarkers or pathogens. They operate through mechanisms like the lateral flow test platform, where a sample containing the biomarker or pathogen is applied to a test strip. If present, the sample binds to specific recognition probes on the strip, indicating a positive result. This binding event is visualized through a colored line. This review discusses the importance, benefits, and potential of nanobiosensors in detecting infectious diseases.
Collapse
Affiliation(s)
- Th S Dhahi
- Electronics Technical Department, Southern Technical University, Basra, Iraq
| | - Alaa Kamal Yousif Dafhalla
- Department of Computer Engineering, College of Computer Science and engineering, University of Hail, Hail, Kingdom of Saudi Arabia
| | - Sawsan Ali Saad
- Department of Computer Engineering, College of Computer Science and engineering, University of Hail, Hail, Kingdom of Saudi Arabia
| | | | | | - Mohamed Elshaikh Elobaid
- Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis (UniMAP), Arau, Perlis, Malaysia
| | - Tijjani Adam
- Faculty of Electronic Engineering & Technology, Universiti Malaysia Perlis (UniMAP), Arau, Perlis, Malaysia
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, Malaysia
- Micro System Technology, Centre of Excellence (CoE), Universiti Malaysia Perlis (UniMAP), Arau, Perlis, Malaysia
- Advanced Communication Engineering, Centre of Excellence (ACE), Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, Malaysia
| | - Subash C B Gopinath
- Faculty of Chemical Engineering & Technology, Universiti Malaysia Perlis (UniMAP), Arau, Perlis, Malaysia
- Institute of Nano Electronic Engineering, Universiti Malaysia Perlis (UniMAP), Kangar, Perlis, Malaysia
- Micro System Technology, Centre of Excellence (CoE), Universiti Malaysia Perlis (UniMAP), Arau, Perlis, Malaysia
| |
Collapse
|
12
|
Futane A, Jadhav P, Mustafa AH, Srinivasan A, Narayanamurthy V. Aptamer-functionalized MOFs and AI-driven strategies for early cancer diagnosis and therapeutics. Biotechnol Lett 2024; 46:1-17. [PMID: 38155321 DOI: 10.1007/s10529-023-03454-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2023] [Revised: 11/07/2023] [Accepted: 11/20/2023] [Indexed: 12/30/2023]
Abstract
Metal-Organic Frameworks (MOFs) have exceptional inherent properties that make them highly suitable for diverse applications, such as catalysis, storage, optics, chemo sensing, and biomedical science and technology. Over the past decades, researchers have utilized various techniques, including solvothermal, hydrothermal, mechanochemical, electrochemical, and ultrasonic, to synthesize MOFs with tailored properties. Post-synthetic modification of linkers, nodal components, and crystallite domain size and morphology can functionalize MOFs to improve their aptamer applications. Advancements in AI and machine learning led to the development of nonporous MOFs and nanoscale MOFs for medical purposes. MOFs have exhibited promise in cancer therapy, with the successful accumulation of a photosensitizer in cancer cells representing a significant breakthrough. This perspective is focused on MOFs' use as advanced materials and systems for cancer therapy, exploring the challenging aspects and promising features of MOF-based cancer diagnosis and treatment. The paper concludes by emphasizing the potential of MOFs as a transformative technology for cancer treatment and diagnosis.
Collapse
Affiliation(s)
- Abhishek Futane
- Department of Engineering Technology, Faculty of Electronics and Computer Technology & Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100, Durian Tunggal, Melaka, Malaysia
| | - Pramod Jadhav
- Faculty of Civil Engineering Technology, Universiti Malaysia Pahang (UMP) Lebuhraya Tun Razak, 26300, Gambang, Kuantan, Pahang, Malaysia
| | - Abu Hasnat Mustafa
- Faculty of Industrial Science and Technology, Universiti Malaysia Pahang, 26300, Gambang, Pahang, Malaysia
| | - Arthi Srinivasan
- Faculty of Chemical and Process Engineering Technology, University Malaysia Pahang (UMP), Lebuhraya Tun Razak, 26300, Gambang, Kunatan, Pahang, Malaysia
| | - Vigneswaran Narayanamurthy
- Department of Engineering Technology, Faculty of Electronics and Computer Technology & Engineering, Universiti Teknikal Malaysia Melaka, Hang Tuah Jaya, 76100, Durian Tunggal, Melaka, Malaysia.
- Department of Biotechnology, Saveetha School of Engineering, Saveetha Institute of Medical and Technical Sciences, Chennai, India.
| |
Collapse
|
13
|
Sitkov N, Ryabko A, Moshnikov V, Aleshin A, Kaplun D, Zimina T. Hybrid Impedimetric Biosensors for Express Protein Markers Detection. MICROMACHINES 2024; 15:181. [PMID: 38398911 PMCID: PMC10890403 DOI: 10.3390/mi15020181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/31/2023] [Revised: 01/22/2024] [Accepted: 01/23/2024] [Indexed: 02/25/2024]
Abstract
Impedimetric biosensors represent a powerful and promising tool for studying and monitoring biological processes associated with proteins and can contribute to the development of new approaches in the diagnosis and treatment of diseases. The basic principles, analytical methods, and applications of hybrid impedimetric biosensors for express protein detection in biological fluids are described. The advantages of this type of biosensors, such as simplicity and speed of operation, sensitivity and selectivity of analysis, cost-effectiveness, and an ability to be integrated into hybrid microfluidic systems, are demonstrated. Current challenges and development prospects in this area are analyzed. They include (a) the selection of materials for electrodes and formation of nanostructures on their surface; (b) the development of efficient methods for biorecognition elements' deposition on the electrodes' surface, providing the specificity and sensitivity of biosensing; (c) the reducing of nonspecific binding and interference, which could affect specificity; (d) adapting biosensors to real samples and conditions of operation; (e) expanding the range of detected proteins; and, finally, (f) the development of biosensor integration into large microanalytical system technologies. This review could be useful for researchers working in the field of impedimetric biosensors for protein detection, as well as for those interested in the application of this type of biosensor in biomedical diagnostics.
Collapse
Affiliation(s)
- Nikita Sitkov
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
- Engineering Centre for Microtechnology and Diagnostics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| | - Andrey Ryabko
- Laboratory of Nonequilibrium Processes in Semiconductors, Ioffe Institute, 26 Politekhnicheskaya, 194021 Saint Petersburg, Russia;
| | - Vyacheslav Moshnikov
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
| | - Andrey Aleshin
- Laboratory of Nonequilibrium Processes in Semiconductors, Ioffe Institute, 26 Politekhnicheskaya, 194021 Saint Petersburg, Russia;
| | - Dmitry Kaplun
- Artificial Intelligence Research Institute, China University of Mining and Technology, 1 Daxue Road, Xuzhou 221116, China;
- Department of Automation and Control Processes, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| | - Tatiana Zimina
- Department of Micro and Nanoelectronics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia; (V.M.); (T.Z.)
- Engineering Centre for Microtechnology and Diagnostics, Saint Petersburg Electrotechnical University “LETI”, 197022 Saint Petersburg, Russia
| |
Collapse
|
14
|
Zhang Q, Ma S, Zhan X, Meng W, Wang H, Liu C, Zhang T, Zhang K, Su S. Smartphone-based wearable microfluidic electrochemical sensor for on-site monitoring of copper ions in sweat without external driving. Talanta 2024; 266:125015. [PMID: 37541004 DOI: 10.1016/j.talanta.2023.125015] [Citation(s) in RCA: 11] [Impact Index Per Article: 11.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2023] [Revised: 07/25/2023] [Accepted: 07/29/2023] [Indexed: 08/06/2023]
Abstract
The directional movement of liquid without exogenous drive can show great potential in portable electrochemical platforms. Herein, we developed a portable electrochemical platform that drove electrolyte flow by surface tension gradient, which can realize collection of electrolyte, flow preconcentration and electrochemical detection of Cu2+. The induced graphene electrodes (LIG) was fabricated using laser direct writing, and flower cluster shaped ZnO nanorods (FC-ZnONRs) were prepared and modified on LIG, which provided a large amount of space for electrolyte to shuttled between the holes of LIG and ZnO, and increased the electrochemical active sites and electrons transport ability. The effect of surface tension gradients driving fluid flow could accelerate preconcentration, shorten detection time (save 300 s of preconcentration time) and enhance electrochemical responses in synergy with the 3D FC-ZnONRs/LIG. The microfluidic system possessed excellent performance for detection of Cu2+ ranged from 1 μg L-1 to 2100 μg L-1 with a low detection limit (LOD) of 0.0368 μg L-1 and high sensitivity of 0.414 μA (μg L-1)-1 cm-2. Additionally, this portable microfluidic system was successfully worn on the skin for analysing Cu2+ in human sweat, and the results showed good consistency with inductively coupled plasma-mass spectrometry (ICP-MS). This novel sensing system provides a sample collection, rapid detection, low cost and easy-to-operate strategy for heavy metal ions analysis in real samples and shows huge application prospects in point-of-care testing.
Collapse
Affiliation(s)
- Qing Zhang
- Key Laboratory of Spin Electron and Nanomaterials of Anhui Higher Education Institutes, School of Chemistry and Chemical Engineering, Suzhou University, Suzhou, 234000, China
| | - Shangshang Ma
- Key Laboratory of Spin Electron and Nanomaterials of Anhui Higher Education Institutes, School of Chemistry and Chemical Engineering, Suzhou University, Suzhou, 234000, China; School of Chemical Engineering&Technology, China University of Mining and Technology, Xuzhou, 221100, China.
| | - Xijie Zhan
- Key Laboratory of Spin Electron and Nanomaterials of Anhui Higher Education Institutes, School of Chemistry and Chemical Engineering, Suzhou University, Suzhou, 234000, China
| | - Wanghan Meng
- Key Laboratory of Spin Electron and Nanomaterials of Anhui Higher Education Institutes, School of Chemistry and Chemical Engineering, Suzhou University, Suzhou, 234000, China
| | - Hongyan Wang
- Key Laboratory of Spin Electron and Nanomaterials of Anhui Higher Education Institutes, School of Chemistry and Chemical Engineering, Suzhou University, Suzhou, 234000, China
| | - Chao Liu
- Key Laboratory of Spin Electron and Nanomaterials of Anhui Higher Education Institutes, School of Chemistry and Chemical Engineering, Suzhou University, Suzhou, 234000, China
| | - Tianren Zhang
- Key Laboratory of Spin Electron and Nanomaterials of Anhui Higher Education Institutes, School of Chemistry and Chemical Engineering, Suzhou University, Suzhou, 234000, China
| | - Keying Zhang
- Key Laboratory of Spin Electron and Nanomaterials of Anhui Higher Education Institutes, School of Chemistry and Chemical Engineering, Suzhou University, Suzhou, 234000, China.
| | - Shao Su
- State Key Laboratory of Organic Electronics and Information Displays & Jiangsu Key Laboratory for Biosensors, Institute of Advanced Materials (IAM), Nanjing University of Posts and Telecommunications, 9 Wenyuan Road, Nanjing, 210023, China.
| |
Collapse
|
15
|
Tai Y, Tian M, Chen Y, You P, Song X, Xu B, Duan C, Jin D. Preparation of PLGA microspheres loaded with niclosamide via microfluidic technology and their inhibition of Caco-2 cell activity in vitro. Front Chem 2023; 11:1249293. [PMID: 37780982 PMCID: PMC10537947 DOI: 10.3389/fchem.2023.1249293] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/28/2023] [Accepted: 09/04/2023] [Indexed: 10/03/2023] Open
Abstract
Niclosamide (NIC) is a multifunctional drug that regulates various signaling pathways and biological processes. It is widely used for the treatment of cancer, viral infections, and metabolic disorders. However, its low water solubility limits its efficacy. In this study, poly(lactic-co-glycolic acid) (PLGA) and hyaluronic acid (HA), which exhibit good biocompatibility, biodegradability, and non-immunogenicity, were conjugated with niclosamide to prepare PLGA-HA-niclosamide polymeric nanoparticles (NIC@PLGA-HA) using microfluidic technology. The obtained microspheres had a uniform size distribution, with an average mean size of 442.0 ± 18.8 nm and zeta potential of -25.4 ± 0.41 mV, indicating their stable dispersion in water. The drug-loading efficiency was 8.70%. The drug-loaded microspheres showed sustained release behavior at pH 7.4 and 5.0, but not at pH 2.0, and the drug release kinetics were described by a quasi-first-order kinetic equation. The effect of the drug-loaded microspheres on the proliferation of Caco-2 cells was detected using the MTT assay. Hydrophilic HA-modified NIC@PLGA-HA microspheres prepared via microfluidic technology increased the cellular uptake by Caco-2 cells. Compared to the same concentration of NIC, the NIC@PLGA-HA microspheres demonstrated a stronger inhibitory effect on Caco-2 cells owing to the combined effect of PLGA, HA, and NIC. Therefore, the pH-responsive NIC@PLGA-HA microspheres synthesized using microfluid technology increased the solubility of NIC and improved its biological activity, thus contributing to the demand for intestinal drug carriers.
Collapse
Affiliation(s)
- Yulei Tai
- School Laboratory of Medicine, Hangzhou Medical College, Hangzhou, Zhejiang, China
- Laboratory of Biomarkers and In Vitro Diagnosis Translation of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Menglun Tian
- School Laboratory of Medicine, Hangzhou Medical College, Hangzhou, Zhejiang, China
- Laboratory of Biomarkers and In Vitro Diagnosis Translation of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Yu Chen
- School Laboratory of Medicine, Hangzhou Medical College, Hangzhou, Zhejiang, China
- Laboratory of Biomarkers and In Vitro Diagnosis Translation of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Peijun You
- School Laboratory of Medicine, Hangzhou Medical College, Hangzhou, Zhejiang, China
- Laboratory of Biomarkers and In Vitro Diagnosis Translation of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Xiaojun Song
- School Laboratory of Medicine, Hangzhou Medical College, Hangzhou, Zhejiang, China
- Laboratory of Biomarkers and In Vitro Diagnosis Translation of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Bangting Xu
- School Laboratory of Medicine, Hangzhou Medical College, Hangzhou, Zhejiang, China
| | - Cidong Duan
- School Laboratory of Medicine, Hangzhou Medical College, Hangzhou, Zhejiang, China
- Laboratory of Biomarkers and In Vitro Diagnosis Translation of Zhejiang Province, Hangzhou, Zhejiang, China
| | - Dazhi Jin
- School Laboratory of Medicine, Hangzhou Medical College, Hangzhou, Zhejiang, China
- Laboratory of Biomarkers and In Vitro Diagnosis Translation of Zhejiang Province, Hangzhou, Zhejiang, China
| |
Collapse
|
16
|
Ganjalizadeh V, Hawkins AR, Schmidt H. Adaptive time modulation technique for multiplexed on-chip particle detection across scales. OPTICA 2023; 10:812-818. [PMID: 38818330 PMCID: PMC11138143 DOI: 10.1364/optica.489068] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Accepted: 05/15/2023] [Indexed: 06/01/2024]
Abstract
Integrated optofluidic biosensors have demonstrated ultrasensitivity down to single particle detection and attomolar target concentrations. However, a wide dynamic range is highly desirable in practice and can usually only be achieved by using multiple detection modalities or sacrificing linearity. Here, we demonstrate an analysis technique that uses temporal excitation at two different time scales to simultaneously enable digital and analog detection of fluorescent targets. We demonstrated the seamless detection of nanobeads across eight orders of magnitude from attomolar to nanomolar concentration. Furthermore, a combination of spectrally varying modulation frequencies and a closed-loop feedback system that provides rapid adjustment of excitation laser powers enables multiplex analysis in the presence of vastly different concentrations. We demonstrated this ability to detect across scales via an analysis of a mixture of fluorescent nanobeads at femtomolar and picomolar concentrations. This technique advances the performance and versatility of integrated biosensors, especially toward point-of-use applications.
Collapse
Affiliation(s)
- Vahid Ganjalizadeh
- School of Engineering, University of California, Santa Cruz, 1156 High Street, Santa Cruz, California, 95064, USA
| | - Aaron R. Hawkins
- Electrical and Computer Engineering Department, Brigham Young University, Provo, Utah, 84602, USA
| | - Holger Schmidt
- School of Engineering, University of California, Santa Cruz, 1156 High Street, Santa Cruz, California, 95064, USA
| |
Collapse
|
17
|
Han X, Lin S, Cheng C, Han X, Tang D. Inspired by game theory: Multi-signal output photoelectrochemical point-of-care immunoassay based on target-triggered organic electronic barriers. Anal Chim Acta 2023; 1265:341362. [PMID: 37230577 DOI: 10.1016/j.aca.2023.341362] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/08/2023] [Revised: 04/30/2023] [Accepted: 05/11/2023] [Indexed: 05/27/2023]
Abstract
This work presents an integrated photoelectrochemical, impedance and colorimetric biosensing platform for flexible detection of cancer markers based on the targeted response by combining liposome amplification strategies and target-induced non-in situ formation of electronic barriers as the signal transduction modality on carbon-modified CdS photoanodes. Inspired by game theory, the carbon layer modified CdS hyperbranched structure with low impedance and high photocurrent response was firstly obtained by surface modification of CdS nanomaterials. Through a liposome-mediated enzymatic reaction amplification strategy, a large number of organic electron barriers were formed by a biocatalytic precipitation (BCP) reaction triggered by horseradish peroxidase released from cleaved liposomes after the introduction of the target molecule, thereby increasing the impedance characteristics of the photoanode as well as attenuating the photocurrent. The BCP reaction in the microplate was accompanied by a significant color change, which opened up a new window for point-of-care testing. Taking carcinoembryonic antigen (CEA) as a proof of concept, the multi-signal output sensing platform showed a satisfactory sensitive response to CEA with an optimal linear range of 20 pg mL-1-100 ng mL-1. The detection limit was as low as 8.4 pg mL-1. Meanwhile, with the assistance of a portable smartphone and a miniature electrochemical workstation, the electrical signal obtained was synchronized with the colorimetric signal to correct the actual target concentration in the sample, further reducing the occurrence of false reports. Importantly, this protocol provides a new idea for the sensitive detection of cancer markers and the construction of a multi-signal output platform.
Collapse
Affiliation(s)
- Xianlin Han
- Department of General Surgery, State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing, 100730, PR China.
| | - Shujin Lin
- College of Biological Science and Engineering, Fuzhou University, Fuzhou, 350108, PR China
| | - Cui Cheng
- College of Biological Science and Engineering, Fuzhou University, Fuzhou, 350108, PR China
| | - Xiao Han
- College of Biological Science and Engineering, Fuzhou University, Fuzhou, 350108, PR China.
| | - Dianping Tang
- Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou, 350108, PR China
| |
Collapse
|
18
|
Henao-Pabon G, Gao N, Prasad KS, Li X. Direct Electron Transfer of Glucose Oxidase on Pre-Anodized Paper/Carbon Electrodes Modified through Zero-Length Cross-Linkers for Glucose Biosensors. BIOSENSORS 2023; 13:566. [PMID: 37232927 PMCID: PMC10216203 DOI: 10.3390/bios13050566] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/03/2023] [Revised: 04/29/2023] [Accepted: 05/08/2023] [Indexed: 05/27/2023]
Abstract
A disposable paper-based glucose biosensor with direct electron transfer (DET) of glucose oxidase (GOX) was developed through simple covalent immobilization of GOX on a carbon electrode surface using zero-length cross-linkers. This glucose biosensor exhibited a high electron transfer rate (ks, 3.363 s-1) as well as good affinity (km, 0.03 mM) for GOX while keeping innate enzymatic activities. Furthermore, the DET-based glucose detection was accomplished by employing both square wave voltammetry and chronoamperometric techniques, and it achieved a glucose detection range from 5.4 mg/dL to 900 mg/dL, which is wider than most commercially available glucometers. This low-cost DET glucose biosensor showed remarkable selectivity, and the use of the negative operating potential avoided interference from other common electroactive compounds. It has great potential to monitor different stages of diabetes from hypoglycemic to hyperglycemic states, especially for self-monitoring of blood glucose.
Collapse
Affiliation(s)
- Gilberto Henao-Pabon
- Biomedical Engineering, University of Texas at El Paso, 500 W University Ave, El Paso, TX 79968, USA
| | - Ning Gao
- Independent Researcher, 206 Via Morella, Encinitas, CA 92024, USA
| | - K. Sudhakara Prasad
- Department of Chemistry & Biochemistry, University of Texas at El Paso, 500 W University Ave, El Paso, TX 79968, USA
- Yenepoya Research Centre, Yenepoya University, Mangalore 575018, Karnataka, India
| | - XiuJun Li
- Biomedical Engineering, University of Texas at El Paso, 500 W University Ave, El Paso, TX 79968, USA
- Department of Chemistry & Biochemistry, University of Texas at El Paso, 500 W University Ave, El Paso, TX 79968, USA
- Forensic Science & Environmental Science and Engineering, 500 W University Ave, El Paso, TX 79968, USA
| |
Collapse
|
19
|
Zhang S, Huang Y, Ren H, Chen Y, Yan S, Dai H, Lv L. Facile and portable multimodal sensing platform driven by photothermal-controlled release system for biomarker detection. Biosens Bioelectron 2023; 235:115413. [PMID: 37224585 DOI: 10.1016/j.bios.2023.115413] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/19/2022] [Revised: 05/08/2023] [Accepted: 05/19/2023] [Indexed: 05/26/2023]
Abstract
Portable, maneuverable and reliable versatile-integrated analytical devices are urgently demanded but still extremely challenging to meet the requirements of point-of-care testing in resource-limited areas. Herein, a multifunctional sensing platform with excellent photothermal performance was implanted into the miniature zone of a paper-based electrochemiluminescent (ECL) biosensor for accurate detection of interleukin-6, which could flexibly interconnect the visualized distance and temperature readout with ultrasensitive ECL response. Concretely, the multipurpose MBene and TaSe2 composites (MBene@TaSe2) prepared via self-assembly approach as target-associated photothermal element was introduced in the paper-based analytical device (PAD) and served as multi-signals trigger. Under the laser irradiation, MBene@TaSe2 probe not only generated heat for rapid temperature output, but also triggered the phase transition behavior of thermoresponsive poly (N-isopropylacrylamide) (pNIPAM) hydrogel to release loaded malachite green (MG) dye for distance-based visual readout. Simultaneously, the released MG was also utilized as effective quencher to decrease the ECL signal of luminol. Benefitting from this dexterous architecture, the speedy preliminary screening and precise quantitative analysis could be subsequently obtained in single-drop sample through one-step sandwich immunoreaction, which avoids additional separation operations and greatly simplifies the analysis procedure. Undeniably, this work provides ingenious insights for advancing the development of convenient and fast multifunction-integrated PAD in family surveillance and intelligent diagnosis.
Collapse
Affiliation(s)
- Shupei Zhang
- College of Chemical and Material Engineering, Quzhou University, Quzhou, Zhejiang, 324000, China
| | - Yitian Huang
- College of Chemistry and Materials, Fujian Normal University, Fuzhou, 350108, PR China
| | - Huizu Ren
- College of Chemistry and Materials, Fujian Normal University, Fuzhou, 350108, PR China
| | - Yanjie Chen
- College of Chemistry and Materials, Fujian Normal University, Fuzhou, 350108, PR China
| | - Shanshan Yan
- College of Chemical and Material Engineering, Quzhou University, Quzhou, Zhejiang, 324000, China
| | - Hong Dai
- College of Chemical and Material Engineering, Quzhou University, Quzhou, Zhejiang, 324000, China.
| | - Liang Lv
- College of Chemical and Material Engineering, Quzhou University, Quzhou, Zhejiang, 324000, China
| |
Collapse
|
20
|
Katla SK, Zhou W, Tavakoli H, Padilla Méndez EL, Li X. Portable in situ temperature-dependent spectroscopy on a low-cost microfluidic platform integrated with a battery-powered thermofoil heater. VIEW 2023; 4:20220053. [PMID: 37928779 PMCID: PMC10621267 DOI: 10.1002/viw.20220053] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2022] [Accepted: 12/26/2022] [Indexed: 01/13/2023] Open
Abstract
A low-cost microfluidic platform integrated with a flexible heater was developed for in situ temperature-dependent spectroscopic measurement at the point of care. After verifying the system by comparing on-chip spectroscopic measurement of methylene blue with the conventional spectroscopy, we demonstrated its applications in temperature-dependent absorption spectroscopy of a model biomolecule, curcumin. The system is portable, battery-powered and requires ultra-low volumes of analytes, which is highly suitable for point-of-care characterization.
Collapse
Affiliation(s)
- Sai Krishna Katla
- Department of Chemistry and Biochemistry, University of Texas at El Paso, El Paso, Texas, USA
| | - Wan Zhou
- Department of Chemistry and Biochemistry, University of Texas at El Paso, El Paso, Texas, USA
| | - Hamed Tavakoli
- Department of Chemistry and Biochemistry, University of Texas at El Paso, El Paso, Texas, USA
| | | | - Xiujun Li
- Department of Chemistry and Biochemistry, University of Texas at El Paso, El Paso, Texas, USA
- Border Biomedical Research Center, & Forensic Science, University of Texas at El Paso, El Paso, Texas, USA
- Environmental Science and Engineering, University of Texas at El Paso, El Paso, Texas, USA
| |
Collapse
|
21
|
Szymczyk A, Ziółkowski R, Malinowska E. Modern Electrochemical Biosensing Based on Nucleic Acids and Carbon Nanomaterials. SENSORS (BASEL, SWITZERLAND) 2023; 23:3230. [PMID: 36991941 PMCID: PMC10057701 DOI: 10.3390/s23063230] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 02/06/2023] [Revised: 03/10/2023] [Accepted: 03/16/2023] [Indexed: 06/19/2023]
Abstract
To meet the requirements of novel therapies, effective treatments should be supported by diagnostic tools characterized by appropriate analytical and working parameters. These are, in particular, fast and reliable responses that are proportional to analyte concentration, with low detection limits, high selectivity, cost-efficient construction, and portability, allowing for the development of point-of-care devices. Biosensors using nucleic acids as receptors has turned out to be an effective approach for meeting the abovementioned requirements. Careful design of the receptor layers will allow them to obtain DNA biosensors that are dedicated to almost any analyte, including ions, low and high molecular weight compounds, nucleic acids, proteins, and even whole cells. The impulse for the application of carbon nanomaterials in electrochemical DNA biosensors is rooted in the possibility to further influence their analytical parameters and adjust them to the chosen analysis. Such nanomaterials enable the lowering of the detection limit, the extension of the biosensor linear response, or the increase in selectivity. This is possible thanks to their high conductivity, large surface-to-area ratio, ease of chemical modification, and introduction of other nanomaterials, such as nanoparticles, into the carbon structures. This review discusses the recent advances on the design and application of carbon nanomaterials in electrochemical DNA biosensors that are dedicated especially to modern medical diagnostics.
Collapse
Affiliation(s)
- Anna Szymczyk
- Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Stanisława Noakowskiego 3, 00-664 Warsaw, Poland
- Doctoral School, Warsaw University of Technology, Plac Politechniki 1, 00-661 Warsaw, Poland
| | - Robert Ziółkowski
- Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Stanisława Noakowskiego 3, 00-664 Warsaw, Poland
| | - Elżbieta Malinowska
- Chair of Medical Biotechnology, Faculty of Chemistry, Warsaw University of Technology, Stanisława Noakowskiego 3, 00-664 Warsaw, Poland
- Center for Advanced Materials and Technologies, Warsaw University of Technology, Poleczki 19, 02-822 Warsaw, Poland
| |
Collapse
|
22
|
Chen M, Lin S, Zhou C, Cui D, Haick H, Tang N. From Conventional to Microfluidic: Progress in Extracellular Vesicle Separation and Individual Characterization. Adv Healthc Mater 2023; 12:e2202437. [PMID: 36541411 DOI: 10.1002/adhm.202202437] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2022] [Revised: 12/07/2022] [Indexed: 12/24/2022]
Abstract
Extracellular vesicles (EVs) are nanoscale membrane vesicles, which contain a wide variety of cargo such as proteins, miRNAs, and lipids. A growing body of evidence suggests that EVs are promising biomarkers for disease diagnosis and therapeutic strategies. Although the excellent clinical value, their use in personalized healthcare practice is not yet feasible due to their highly heterogeneous nature. Taking the difficulty of isolation and the small size of EVs into account, the characterization of EVs at a single-particle level is both imperative and challenging. In a bid to address this critical point, more research has been directed into a microfluidic platform because of its inherent advantages in sensitivity, specificity, and throughput. This review discusses the biogenesis and heterogeneity of EVs and takes a broad view of state-of-the-art advances in microfluidics-based EV research, including not only EV separation, but also the single EV characterization of biophysical detection and biochemical analysis. To highlight the advantages of microfluidic techniques, conventional technologies are included for comparison. The current status of artificial intelligence (AI) for single EV characterization is then presented. Furthermore, the challenges and prospects of microfluidics and its combination with AI applications in single EV characterization are also discussed. In the foreseeable future, recent breakthroughs in microfluidic platforms are expected to pave the way for single EV analysis and improve applications for precision medicine.
Collapse
Affiliation(s)
- Mingrui Chen
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, P. R. China
| | - Shujing Lin
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, P. R. China
| | - Cheng Zhou
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, P. R. China
| | - Daxiang Cui
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, P. R. China
| | - Hossam Haick
- Department of Chemical Engineering and Russell Berrie Nanotechnology Institute, Technion-Israel Institute of Technology, Haifa, 3200003, Israel
| | - Ning Tang
- School of Electronic Information and Electrical Engineering, Shanghai Jiao Tong University, Shanghai, 200240, P. R. China
| |
Collapse
|
23
|
Yu Z, Qiu C, Huang L, Gao Y, Tang D. Microelectromechanical Microsystems-Supported Photothermal Immunoassay for Point-of-Care Testing of Aflatoxin B1 in Foodstuff. Anal Chem 2023; 95:4212-4219. [PMID: 36780374 DOI: 10.1021/acs.analchem.2c05617] [Citation(s) in RCA: 88] [Impact Index Per Article: 44.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/15/2023]
Abstract
Accurate identification of acutely toxic and low-fatality mycotoxins on a large scale in a quick and cheap manner is critical for reducing population mortality. Herein, a portable photothermal immunosensing platform supported by a microelectromechanical microsystem (MEMS) without enzyme involvement was reported for point-of-care testing of mycotoxins (in the case of aflatoxin B1, AFB1) in food based on the precise satellite structure of Au nanoparticles. The synthesized Au nanoparticles with a well-defined, graded satellite structure exhibited a significantly enhanced photothermal response and were coupled by AFB1 antibodies to form signal conversion probes by physisorption for further target-promoted competitive responses in microplates. In addition, a coin-sized miniature NIR camera device was constructed for temperature acquisition during target testing based on advanced MEMS fabrication technology to address the limitation of expensive signal acquisition components of current photothermal sensors. The proposed MEMS readout-based microphotothermal test method provides excellent AFB1 response in the range of 0.5-500 ng g-1 with detection limits as low as 0.27 ng g-1. In addition, the main reasons for the efficient photothermal transduction efficiency of Au with different graded structures were analyzed by finite element simulations, providing theoretical guidance for the development of new Au-based photothermal agents. In conclusion, the proposed portable micro-photothermal test system offers great potential for point-of-care diagnostics for residents, which will continue to facilitate immediate food safety identification in resource-limited regions.
Collapse
Affiliation(s)
- Zhichao Yu
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Chicheng Qiu
- Zijin School of Geology and Mining, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Lingting Huang
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Yuan Gao
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China
| | - Dianping Tang
- Key Laboratory of Analytical Science for Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China
| |
Collapse
|
24
|
Mostafa GAE, El-Tohamy MF, Alrabiah H. Prospective of Agro-Waste Husks for Biogenic Synthesis of Polymeric-Based CeO 2/NiO Nanocomposite Sensor for Determination of Mebeverine Hydrochloride. Molecules 2023; 28:2095. [PMID: 36903341 PMCID: PMC10004120 DOI: 10.3390/molecules28052095] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/27/2023] [Revised: 02/12/2023] [Accepted: 02/20/2023] [Indexed: 03/12/2023] Open
Abstract
BACKGROUND The remarkable properties of nickel oxide (NiO) and cerium oxide (CeO2) nanostructures have attracted considerable interest in these nanocomposites as potential electroactive materials for sensor construction. METHODS The mebeverine hydrochloride (MBHCl) content of commercial formulations was determined in this study using a unique factionalized CeO2/NiO-nanocomposite-coated membrane sensor. RESULTS Mebeverine-phosphotungstate (MB-PT) was prepared by adding phosphotungstic acid to mebeverine hydrochloride and mixing with a polymeric matrix (polyvinyl chloride, PVC) and plasticizing agent o-nitrophenyl octyl ether. The new suggested sensor showed an excellent linear detection range of the selected analyte at 1.0 × 10-8-1.0 × 10-2 mol L-1 with regression equation EmV = (-29.429 ± 0.2) log [MB] + 347.86. However, the unfunctionalized sensor MB-PT displayed less linearity at 1.0 × 10-5-1.0 × 10-2 mol L-1 drug solution with regression equation EmV = (-26.603 ± 0.5) log [MB] + 256.81. By considering a number of factors, the applicability and validity of the suggested potentiometric system were improved following the rules of analytical methodological requirements. CONCLUSION The created potentiometric technique worked well for determining MB in bulk substance and in medical commercial samples.
Collapse
Affiliation(s)
- Gamal A. E. Mostafa
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia
| | - Maha F. El-Tohamy
- Department of Chemistry, College of Science, King Saud University, P.O. Box 22452, Riyadh 11495, Saudi Arabia
| | - Haitham Alrabiah
- Department of Pharmaceutical Chemistry, College of Pharmacy, King Saud University, P.O. Box 2457, Riyadh 11451, Saudi Arabia
| |
Collapse
|
25
|
Yang J, Wang X, Sun Y, Chen B, Hu F, Guo C, Yang T. Recent Advances in Colorimetric Sensors Based on Gold Nanoparticles for Pathogen Detection. BIOSENSORS 2022; 13:29. [PMID: 36671864 PMCID: PMC9856207 DOI: 10.3390/bios13010029] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2022] [Revised: 12/09/2022] [Accepted: 12/23/2022] [Indexed: 05/28/2023]
Abstract
Infectious pathogens cause severe threats to public health due to their frightening infectivity and lethal capacity. Rapid and accurate detection of pathogens is of great significance for preventing their infection. Gold nanoparticles have drawn considerable attention in colorimetric biosensing during the past decades due to their unique physicochemical properties. Colorimetric diagnosis platforms based on functionalized AuNPs are emerging as a promising pathogen-analysis technique with the merits of high sensitivity, low-cost, and easy operation. This review summarizes the recent development in this field. We first introduce the significance of detecting pathogens and the characteristics of gold nanoparticles. Four types of colorimetric strategies, including the application of indirect target-mediated aggregation, chromogenic substrate-mediated catalytic activity, point-of-care testing (POCT) devices, and machine learning-assisted colorimetric sensor arrays, are systematically introduced. In particular, three biomolecule-functionalized AuNP-based colorimetric sensors are described in detail. Finally, we conclude by presenting our subjective views on the present challenges and some appropriate suggestions for future research directions of colorimetric sensors.
Collapse
Affiliation(s)
- Jianyu Yang
- Institute of Materials Science and Devices, School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Xin Wang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang 110819, China
| | - Yuyang Sun
- Institute of Materials Science and Devices, School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Bo Chen
- Institute of Materials Science and Devices, School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Fangxin Hu
- Institute of Materials Science and Devices, School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Chunxian Guo
- Institute of Materials Science and Devices, School of Materials Science and Engineering, Suzhou University of Science and Technology, Suzhou 215009, China
| | - Ting Yang
- Research Center for Analytical Sciences, Department of Chemistry, College of Sciences, Northeastern University, Shenyang 110819, China
| |
Collapse
|
26
|
Recent progress in microfluidic biosensors with different driving forces. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116894] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
|
27
|
Xiao B, Zhao R, Wang N, Zhang J, Sun X, Chen A. Recent advances in centrifugal microfluidic chip-based loop-mediated isothermal amplification. Trends Analyt Chem 2022. [DOI: 10.1016/j.trac.2022.116836] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|