1
|
Marlar R, Abbas F, Obeid R, Frisbie S, Ghazoul A, Rezaee A, Sims J, Rampazzo A, Bassiri Gharb B. A meta-analysis of perfusion parameters affecting weight gain in ex vivo perfusion. Artif Organs 2025; 49:7-20. [PMID: 39157933 PMCID: PMC11687208 DOI: 10.1111/aor.14841] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/05/2024] [Revised: 07/08/2024] [Accepted: 07/27/2024] [Indexed: 08/20/2024]
Abstract
BACKGROUND Ex vivo machine perfusion (EVMP) has been established to extend viability of donor organs. However, EVMP protocols are inconsistent. We hypothesize that there is a significant relationship between specific parameters during EVMP and perfusion outcomes. METHODS A meta-analysis of literature was conducted in accordance with the Preferred Reporting Items for Systematic Review and Meta-Analysis (PRISMA) Statement. The search encompassed articles published before July 25, 2023. PubMed, Embase, and CENTRAL databases were screened using search terms "ex-vivo," "ex-situ," "machine," and "perfusion." Weight gain, an indicator of organ viability, was chosen to compare outcomes. Extracted variables included perfused organ, warm and cold ischemia time before perfusion, perfusion duration, perfusate flow, pressure, temperature, perfusate composition (presence of cellular or acellular oxygen carrier, colloids, and other supplements) and percent weight change. Data were analyzed using SPSS statistical software. RESULTS Overall, 44 articles were included. Red blood cell-based perfusates resulted in significantly lower weight gain compared to acellular perfusates without oxygen carriers (11.3% vs. 27.0%, p < 0.001). Hemoglobin-based oxygen carriers resulted in significantly lower weight gain compared to acellular perfusates (16.5% vs. 27%, p = 0.006). Normothermic perfusion led to the least weight gain (14.6%), significantly different from hypothermic (24.3%) and subnormothermic (25.0%) conditions (p < 0.001), with no significant difference between hypothermic and subnormothermic groups (24.3% vs. 25.0%, p = 0.952). There was a positive correlation between flow rate and weight gain (ß = 13.1, R = 0.390, p < 0.001). CONCLUSIONS Oxygen carriers, low flow rates, and normothermic perfusate temperature appear to improve outcomes in EVMP. These findings offer opportunities for improving organ transplantation outcomes.
Collapse
Affiliation(s)
- Riley Marlar
- Department of Plastic SurgeryCleveland ClinicClevelandOhioUSA
| | - Fuad Abbas
- Department of Plastic SurgeryCleveland ClinicClevelandOhioUSA
| | - Rommy Obeid
- Department of Plastic SurgeryCleveland ClinicClevelandOhioUSA
| | - Sean Frisbie
- Department of Plastic SurgeryCleveland ClinicClevelandOhioUSA
| | - Adam Ghazoul
- Department of Plastic SurgeryCleveland ClinicClevelandOhioUSA
| | - Ava Rezaee
- Department of Plastic SurgeryCleveland ClinicClevelandOhioUSA
| | - Jack Sims
- Department of Plastic SurgeryCleveland ClinicClevelandOhioUSA
| | | | | |
Collapse
|
2
|
Ton C, Salehi S, Abasi S, Aggas JR, Liu R, Brandacher G, Guiseppi-Elie A, Grayson WL. Methods of ex vivo analysis of tissue status in vascularized composite allografts. J Transl Med 2023; 21:609. [PMID: 37684651 PMCID: PMC10492401 DOI: 10.1186/s12967-023-04379-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/05/2023] [Accepted: 07/21/2023] [Indexed: 09/10/2023] Open
Abstract
Vascularized composite allotransplantation can improve quality of life and restore functionality. However, the complex tissue composition of vascularized composite allografts (VCAs) presents unique clinical challenges that increase the likelihood of transplant rejection. Under prolonged static cold storage, highly damage-susceptible tissues such as muscle and nerve undergo irreversible degradation that may render allografts non-functional. Skin-containing VCA elicits an immunogenic response that increases the risk of recipient allograft rejection. The development of quantitative metrics to evaluate VCAs prior to and following transplantation are key to mitigating allograft rejection. Correspondingly, a broad range of bioanalytical methods have emerged to assess the progression of VCA rejection and characterize transplantation outcomes. To consolidate the current range of relevant technologies and expand on potential for development, methods to evaluate ex vivo VCA status are herein reviewed and comparatively assessed. The use of implantable physiological status monitoring biochips, non-invasive bioimpedance monitoring to assess edema, and deep learning algorithms to fuse disparate inputs to stratify VCAs are identified.
Collapse
Affiliation(s)
- Carolyn Ton
- Department of Biomedical Engineering, Johns Hopkins University, 400 North Broadway, Smith Building 5023, Baltimore, MD, 21231, USA
- Translational Tissue Engineering Center, Johns Hopkins University, 400 North Broadway, Smith Building 5023, Baltimore, MD, 21231, USA
| | - Sara Salehi
- Department of Biomedical Engineering, Johns Hopkins University, 400 North Broadway, Smith Building 5023, Baltimore, MD, 21231, USA
- Translational Tissue Engineering Center, Johns Hopkins University, 400 North Broadway, Smith Building 5023, Baltimore, MD, 21231, USA
| | - Sara Abasi
- Department of Biomedical Engineering, Center for Bioelectronics, Biosensors and Biochips (C3B®), Texas A&M University, Emerging Technologies Building 3120, 101 Bizzell St, College Station, TX, 77843, USA
- Department of Electrical and Computer Engineering, Center for Bioelectronics, Biosensors and Biochips (C3B®), Texas A&M University, Emerging Technologies Building 3120, 101 Bizzell St, College Station, TX, 77843, USA
- Media and Metabolism, Wildtype, Inc., 2325 3rd St., San Francisco, CA, 94107, USA
| | - John R Aggas
- Department of Biomedical Engineering, Center for Bioelectronics, Biosensors and Biochips (C3B®), Texas A&M University, Emerging Technologies Building 3120, 101 Bizzell St, College Station, TX, 77843, USA
- Department of Electrical and Computer Engineering, Center for Bioelectronics, Biosensors and Biochips (C3B®), Texas A&M University, Emerging Technologies Building 3120, 101 Bizzell St, College Station, TX, 77843, USA
- Test Development, Roche Diagnostics, 9115 Hague Road, Indianapolis, IN, 46256, USA
| | - Renee Liu
- Department of Biomedical Engineering, Johns Hopkins University, 400 North Broadway, Smith Building 5023, Baltimore, MD, 21231, USA
- Translational Tissue Engineering Center, Johns Hopkins University, 400 North Broadway, Smith Building 5023, Baltimore, MD, 21231, USA
| | - Gerald Brandacher
- Department of Plastic and Reconstructive Surgery, Vascularized Composite Allotransplantation (VCA) Laboratory, Reconstructive Transplantation Program, Center for Advanced Physiologic Modeling (CAPM), Johns Hopkins University, Ross Research Building/Suite 749D, 720 Rutland Avenue, Baltimore, MD, 21205, USA.
| | - Anthony Guiseppi-Elie
- Department of Biomedical Engineering, Center for Bioelectronics, Biosensors and Biochips (C3B®), Texas A&M University, Emerging Technologies Building 3120, 101 Bizzell St, College Station, TX, 77843, USA.
- Department of Electrical and Computer Engineering, Center for Bioelectronics, Biosensors and Biochips (C3B®), Texas A&M University, Emerging Technologies Building 3120, 101 Bizzell St, College Station, TX, 77843, USA.
- Department of Cardiovascular Sciences, Houston Methodist Institute for Academic Medicine and Houston Methodist Research Institute, 6670 Bertner Ave., Houston, TX, USA.
- ABTECH Scientific, Inc., Biotechnology Research Park, 800 East Leigh Street, Richmond, VA, USA.
| | - Warren L Grayson
- Department of Biomedical Engineering, Johns Hopkins University, 400 North Broadway, Smith Building 5023, Baltimore, MD, 21231, USA.
- Translational Tissue Engineering Center, Johns Hopkins University, 400 North Broadway, Smith Building 5023, Baltimore, MD, 21231, USA.
- Department of Chemical and Biomolecular Engineering, Johns Hopkins University, Baltimore, MD, USA.
- Department of Materials Science and Engineering, Johns Hopkins University, Baltimore, MD, USA.
- Institute for Nanobiotechnology, Johns Hopkins University, Baltimore, MD, USA.
| |
Collapse
|
3
|
Pradegan N, Gallo M, Fabozzo A, Toscano G, Tarzia V, Gerosa G. Nonischemic Donor Heart Preservation: New Milestone in Heart Transplantation History. ASAIO J 2023; 69:725-733. [PMID: 37319037 DOI: 10.1097/mat.0000000000002001] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 06/17/2023] Open
Abstract
Heart transplantation is considered the gold standard for the treatment of advanced end-stage heart failure. However, standard donors after brain death are decreasing, whereas patients on the heart transplant waitlist are constantly rising. The introduction of the ex vivo machine perfusion device has been a turning point; in fact, these systems are able to significantly reduce ischemic times and have a potential effect on ischemia-related damage reduction. From a clinical standpoint, these machines show emerging results in terms of heart donor pool expansion, making marginal donors and donor grafts after circulatory death suitable for donation. This article aims to review mechanisms and preclinical and clinical outcomes of currently available ex vivo perfusion systems, and to explore the future fields of application of these technologies.
Collapse
Affiliation(s)
- Nicola Pradegan
- From the Cardiac Surgery Unit, Heart Transplantation Program, Cardiac, Thoracic, Vascular Sciences and Public Health Department, Padova University Hospital, Padova, Italy
| | | | | | | | | | | |
Collapse
|
4
|
Portillo DJ, Bayliss L, Rivas S, Pineda G, Kaur S, Bunegin L, Hood RL. Characterizing and Tuning Perfusion Parameters Within an Innovative, Versatile Oxygenating Perfusion System. Ann Biomed Eng 2021; 49:3154-3164. [PMID: 34414529 DOI: 10.1007/s10439-021-02843-7] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Accepted: 07/25/2021] [Indexed: 12/20/2022]
Abstract
The advantages of oxygenated perfusion are continuing to be demonstrated by many groups focused on improving the efficacy of tissue preservation for transplant, bioreactors for studies of basic tissue physiology, and closed-loop resuscitation. This work presents a novel and portable device that supplies oxygenated and pulsatile perfusion, both of which are regulated by a single pump-oxygenator component comprised of silicone tubes that are cyclically inflated/deflated with compressed oxygen. In this study, pump variables (oxygen supply pressure and length of a silicone tube) were evaluated against hydraulic elements that mimicked the vascular resistance of kidneys, livers, and hearts. The perfusion pressures, flow rates, and oxygenation rates produced by the device were characterized for all configurations of pump variables, and the pulse rates were tuned to improve performance. The device supplied perfusion pressures ranging from 3.5 to 109 mmHg, flow rates ranging from 1.4 to 71.8 mL min-1, and oxygenation rates up to 316.6 µmol min-1. From those results, it was determined that the device was capable of achieving perfusion parameters used in previous kidney, liver, and heart preservation studies. Ultimately, this research demonstrated the efficacy of a novel device that is designed to supply oxygenated perfusion across a range of applications.
Collapse
Affiliation(s)
- Daniel J Portillo
- Department of Mechanical Engineering, The University of Texas at San Antonio, 1 UTSA Circle, San Antonio, TX, 78249, USA
| | - Lauren Bayliss
- Department of Emergency Medicine, McGovern Medical School at The University of Texas Health Science Center at Houston, 6431 Fannin, JJL 260G, Houston, TX, 77030, USA.,Department of Internal Medicine, The University of Texas-Rio Grande Valley School of Medicine, 1201 W University Dr., Edinburg, TX, 78539, USA
| | - Stephen Rivas
- Department of Mechanical Engineering, The University of Texas at San Antonio, 1 UTSA Circle, San Antonio, TX, 78249, USA
| | - Gabriela Pineda
- Department of Mechanical Engineering, The University of Texas at San Antonio, 1 UTSA Circle, San Antonio, TX, 78249, USA
| | - Sukhwinder Kaur
- Department of Biomedical Engineering, The University of Texas at San Antonio, 1 UTSA Circle, San Antonio, TX, 78249, USA
| | - Leonid Bunegin
- Vascular Perfusion Solutions, Inc., San Antonio, TX, USA
| | - R Lyle Hood
- Department of Mechanical Engineering, The University of Texas at San Antonio, 1 UTSA Circle, San Antonio, TX, 78249, USA. .,Department of Biomedical Engineering, The University of Texas at San Antonio, 1 UTSA Circle, San Antonio, TX, 78249, USA. .,Department of Emergency Medicine, The University of Texas Health Science Center at San Antonio, 7703 Floyd Curl Drive, San Antonio, TX, 78229, USA.
| |
Collapse
|
5
|
Kvietkauskas M, Zitkute V, Leber B, Strupas K, Stiegler P, Schemmer P. The Role of Metabolomics in Current Concepts of Organ Preservation. Int J Mol Sci 2020; 21:6607. [PMID: 32927605 PMCID: PMC7555311 DOI: 10.3390/ijms21186607] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2020] [Revised: 09/06/2020] [Accepted: 09/08/2020] [Indexed: 12/16/2022] Open
Abstract
In solid organ transplantation (Tx), both survival rates and quality of life have improved dramatically over the last few decades. Each year, the number of people on the wait list continues to increase, widening the gap between organ supply and demand. Therefore, the use of extended criteria donor grafts is growing, despite higher susceptibility to ischemia-reperfusion injury (IRI) and consecutive inferior Tx outcomes. Thus, tools to characterize organ quality prior to Tx are crucial components for Tx success. Innovative techniques of metabolic profiling revealed key pathways and mechanisms involved in IRI occurring during organ preservation. Although large-scale trials are needed, metabolomics appears to be a promising tool to characterize potential biomarkers, for the assessment of graft quality before Tx and evaluate graft-related outcomes. In this comprehensive review, we summarize the currently available literature on the use of metabolomics in solid organ Tx, with a special focus on metabolic profiling during graft preservation to assess organ quality prior to Tx.
Collapse
Affiliation(s)
- Mindaugas Kvietkauskas
- General, Visceral and Transplant Surgery, Department of Surgery, Medical University of Graz, Auenbruggerpl. 2, Graz 8036, Austria; (M.K.); (V.Z.); (B.L.); (P.S.)
- Faculty of Medicine, Vilnius University, M. K. Ciurlionio 21, 03101 Vilnius, Lithuania;
| | - Viktorija Zitkute
- General, Visceral and Transplant Surgery, Department of Surgery, Medical University of Graz, Auenbruggerpl. 2, Graz 8036, Austria; (M.K.); (V.Z.); (B.L.); (P.S.)
- Faculty of Medicine, Vilnius University, M. K. Ciurlionio 21, 03101 Vilnius, Lithuania;
| | - Bettina Leber
- General, Visceral and Transplant Surgery, Department of Surgery, Medical University of Graz, Auenbruggerpl. 2, Graz 8036, Austria; (M.K.); (V.Z.); (B.L.); (P.S.)
| | - Kestutis Strupas
- Faculty of Medicine, Vilnius University, M. K. Ciurlionio 21, 03101 Vilnius, Lithuania;
| | - Philipp Stiegler
- General, Visceral and Transplant Surgery, Department of Surgery, Medical University of Graz, Auenbruggerpl. 2, Graz 8036, Austria; (M.K.); (V.Z.); (B.L.); (P.S.)
| | - Peter Schemmer
- General, Visceral and Transplant Surgery, Department of Surgery, Medical University of Graz, Auenbruggerpl. 2, Graz 8036, Austria; (M.K.); (V.Z.); (B.L.); (P.S.)
| |
Collapse
|
6
|
Saemann L, Guo Y, Ding Q, Zhou P, Karck M, Szabó G, Wenzel F. Machine perfusion of circulatory determined death hearts: A scoping review. Transplant Rev (Orlando) 2020; 34:100551. [PMID: 32498975 DOI: 10.1016/j.trre.2020.100551] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/24/2020] [Revised: 04/25/2020] [Accepted: 04/26/2020] [Indexed: 10/24/2022]
Abstract
BACKGROUND Ex vivo machine perfusion (EVMP) is reported to can successfully be applied for donor heart preservation. To respond to the organ shortage, some centres also accept hearts from marginal donors such as non-heart beating donors (NHBD) or hearts donated after cardiac death (DCD) for heart transplantation (HTx). Clinical as well as preclinical science on EVMP of DCD hearts seems to be promising but the ideal perfusion practice itself appears unclear. OBJECTIVES In accordance with the Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews (PRISMA), this systematic review scopes all EVMP techniques for human and animal DCD heart preservation and addresses three specific questions, which refer to (a) the perfusion solutions, (b) the perfusion parameters and respective target values and (c) if possible, a direct comparison between cold static storage (CSS) and EVMP. RESULTS Search results predominantly consisted of animal studies. Either perfusion with a crystalloid or blood-based solution, each with cardioplegic or non-cardioplegic properties was used. Some perfusates were supplemented with specific pharmacological medication to block pathophysiological pathways, which are involved in ischemia/reperfusion injury or edema formation. Besides normothermic EVMP with oxygenated blood, a wide range of temperature was applied in all approaches, with the lowest temperature at 4 °C. Pressure controlled anterograde Langendorff perfusion was applied mostly. If investigated, crystalloid machine perfusion was presented superior to CSS. CONCLUSIONS Only blood based EVMP was introduced into clinical practice. More research, clinical as well as preclinical, is needed to develop the ideal EVMP technique, in terms of blood or crystalloid perfusion.
Collapse
Affiliation(s)
- Lars Saemann
- Department of Cardiac Surgery, University Hospital Heidelberg, Im Neuenheimer Feld 326, Heidelberg 69120, Germany; Faculty Medical and Life Sciences, Furtwangen University, Jakob-Kienzle-Straße 17, Villingen-Schwenningen 78054, Germany.
| | - Yuxing Guo
- Department of Cardiac Surgery, University Hospital Heidelberg, Im Neuenheimer Feld 326, Heidelberg 69120, Germany
| | - Qingwei Ding
- Department of Cardiac Surgery, University Hospital Heidelberg, Im Neuenheimer Feld 326, Heidelberg 69120, Germany
| | - Pengyu Zhou
- Department of Cardiac Surgery, University Hospital Heidelberg, Im Neuenheimer Feld 326, Heidelberg 69120, Germany
| | - Matthias Karck
- Department of Cardiac Surgery, University Hospital Heidelberg, Im Neuenheimer Feld 326, Heidelberg 69120, Germany
| | - Gábor Szabó
- Department of Cardiac Surgery, University Hospital Heidelberg, Im Neuenheimer Feld 326, Heidelberg 69120, Germany
| | - Folker Wenzel
- Faculty Medical and Life Sciences, Furtwangen University, Jakob-Kienzle-Straße 17, Villingen-Schwenningen 78054, Germany.
| |
Collapse
|
7
|
Braik A, Lahouel M, Merabet R, Djebar MR, Morin D. Myocardial protection by propolis during prolonged hypothermic preservation. Cryobiology 2019; 88:29-37. [DOI: 10.1016/j.cryobiol.2019.04.003] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 04/04/2019] [Accepted: 04/08/2019] [Indexed: 11/30/2022]
|
8
|
Outcomes of Donation After Circulatory Death Heart Transplantation in Australia. J Am Coll Cardiol 2019; 73:1447-1459. [DOI: 10.1016/j.jacc.2018.12.067] [Citation(s) in RCA: 113] [Impact Index Per Article: 18.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 07/24/2018] [Revised: 12/10/2018] [Accepted: 12/11/2018] [Indexed: 01/07/2023]
|
9
|
Steroids Limit Myocardial Edema During Ex Vivo Perfusion of Hearts Donated After Circulatory Death. Ann Thorac Surg 2018; 105:1763-1770. [DOI: 10.1016/j.athoracsur.2018.01.004] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 05/02/2017] [Revised: 10/21/2017] [Accepted: 01/03/2018] [Indexed: 12/18/2022]
|
10
|
White CW, Messer SJ, Large SR, Conway J, Kim DH, Kutsogiannis DJ, Nagendran J, Freed DH. Transplantation of Hearts Donated after Circulatory Death. Front Cardiovasc Med 2018; 5:8. [PMID: 29487855 PMCID: PMC5816942 DOI: 10.3389/fcvm.2018.00008] [Citation(s) in RCA: 85] [Impact Index Per Article: 12.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/05/2017] [Accepted: 01/19/2018] [Indexed: 12/17/2022] Open
Abstract
Cardiac transplantation has become limited by a critical shortage of suitable organs from brain-dead donors. Reports describing the successful clinical transplantation of hearts donated after circulatory death (DCD) have recently emerged. Hearts from DCD donors suffer significant ischemic injury prior to organ procurement; therefore, the traditional approach to the transplantation of hearts from brain-dead donors is not applicable to the DCD context. Advances in our understanding of ischemic post-conditioning have facilitated the development of DCD heart resuscitation strategies that can be used to minimize ischemia-reperfusion injury at the time of organ procurement. The availability of a clinically approved ex situ heart perfusion device now allows DCD heart preservation in a normothermic beating state and minimizes exposure to incremental cold ischemia. This technology also facilitates assessments of organ viability to be undertaken prior to transplantation, thereby minimizing the risk of primary graft dysfunction. The application of a tailored approach to DCD heart transplantation that focuses on organ resuscitation at the time of procurement, ex situ preservation, and pre-transplant assessments of organ viability has facilitated the successful clinical application of DCD heart transplantation. The transplantation of hearts from DCD donors is now a clinical reality. Investigating ways to optimize the resuscitation, preservation, evaluation, and long-term outcomes is vital to ensure a broader application of DCD heart transplantation in the future.
Collapse
Affiliation(s)
| | - Simon J Messer
- Papworth Hospital NHS Foundation Trust, Cambridge, United Kingdom
| | - Stephen R Large
- Papworth Hospital NHS Foundation Trust, Cambridge, United Kingdom
| | | | - Daniel H Kim
- Cardiology, University of Alberta, Edmonton, AB, Canada
| | | | - Jayan Nagendran
- Cardiac Surgery, University of Alberta, Edmonton, AB, Canada
| | - Darren H Freed
- Cardiac Surgery, University of Alberta, Edmonton, AB, Canada.,Department of Physiology, University of Alberta, Edmonton, AB, Canada.,Department of Biomedical Engineering, University of Alberta, Edmonton, AB, Canada
| |
Collapse
|
11
|
Pusswald G, Tropper E, Kryspin-Exner I, Moser D, Klug S, Auff E, Dal-Bianco P, Lehrner J. Health-Related Quality of Life in Patients with Subjective Cognitive Decline and Mild Cognitive Impairment and its Relation to Activities of Daily Living. J Alzheimers Dis 2016; 47:479-86. [PMID: 26401569 DOI: 10.3233/jad-150284] [Citation(s) in RCA: 63] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
BACKGROUND Health related quality of life (HRQOL) is an important issue in the context of dementia care. OBJECTIVES The purpose of this study was to investigate HRQOL in patients with subjective cognitive decline (SCD) and mild cognitive impairment (MCI) and its relation to Activity of Daily Living (ADL). METHODS In this cross sectional study, four experimental groups (each n = 98), controls, SCD, naMCI and aMCI, were compared. For data collection, neuropsychological methods (NTBV) and psychological questionnaires (SF-36 and B-ADL) were used. Multivariate analysis of variance was calculated to detect differences in HRQOL between groups. Correlations between HRQOL and ADL were explored. RESULTS The dimensions of HRQOL showed mainly consistent differences between the control and the SCD group and MCI subgroups. In almost every dimension of HRQOL, the control group scored higher than subjects with SCD, naMCI, or aMCI. The controls showed low to moderate negative correlations between HQROL and B-ADL in some dimensions of the HRQOL. In the SCD group, low negative correlations with ADL were observed in some HRQOL scales. Low to moderate correlations were found between each scale of the SF-36 and the B-ADL in both MCI subtypes. We found gender differences in HRQOL. CONCLUSION In conclusion, we could demonstrate that patients with SCD report reduced quality of life. This knowledge is important to get a better understanding of the individuals with SCD and may pave the way for the development of early intervention.
Collapse
Affiliation(s)
- Gisela Pusswald
- Department of Neurology, Medical University of Vienna, Vienna, Austria
| | - Elisa Tropper
- Faculty of Psychology, University of Vienna, Vienna, Austria
| | | | - Doris Moser
- Department of Neurology, Medical University of Vienna, Vienna, Austria
| | - Stefanie Klug
- Department of Neurology, Medical University of Vienna, Vienna, Austria
| | - Eduard Auff
- Department of Neurology, Medical University of Vienna, Vienna, Austria
| | - Peter Dal-Bianco
- Department of Neurology, Medical University of Vienna, Vienna, Austria
| | - Johann Lehrner
- Department of Neurology, Medical University of Vienna, Vienna, Austria
| |
Collapse
|
12
|
Tolboom H, Olejníčková V, Reser D, Rosser B, Wilhelm MJ, Gassmann M, Bogdanova A, Falk V. Moderate hypothermia duringex vivomachine perfusion promotes recovery of hearts donated after cardiocirculatory death. Eur J Cardiothorac Surg 2015; 49:25-31. [DOI: 10.1093/ejcts/ezv066] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 10/02/2014] [Accepted: 01/18/2015] [Indexed: 11/13/2022] Open
|
13
|
White CW, Hasanally D, Mundt P, Li Y, Xiang B, Klein J, Müller A, Ambrose E, Ravandi A, Arora RC, Lee TW, Hryshko LV, Large S, Tian G, Freed DH. A whole blood–based perfusate provides superior preservation of myocardial function during ex vivo heart perfusion. J Heart Lung Transplant 2015; 34:113-121. [DOI: 10.1016/j.healun.2014.09.021] [Citation(s) in RCA: 56] [Impact Index Per Article: 5.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/08/2014] [Revised: 09/04/2014] [Accepted: 09/19/2014] [Indexed: 11/29/2022] Open
|
14
|
Ou R, Lim Y, Choong J, Esmore D, Salamonsen R, McLean C, Forbes J, Bailey M, Rosenfeldt F. Low-Flow Hypothermic Crystalloid Perfusion Is Superior to Cold Storage During Prolonged Heart Preservation. Transplant Proc 2014; 46:3309-13. [DOI: 10.1016/j.transproceed.2014.09.149] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2014] [Accepted: 09/23/2014] [Indexed: 11/15/2022]
|
15
|
Comparative analysis of preservation method and intermittent perfusion volume on the expression of endothelial and inflammatory markers by coronal artery and myocardium in porcine donor hearts. ASAIO J 2014; 60:681-7. [PMID: 25232770 DOI: 10.1097/mat.0000000000000148] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022] Open
Abstract
Although continuous perfusion of donor hearts for preservation during transportation has been widely applied, intermittent perfusion has been suggested as an alternative. The aim of this study was to identify the optimal intermittent perfusion protocol by investigating the effects of perfusion volume on endothelial and inflammatory marker expression by the coronary artery. Donor porcine hearts were perfused with various volumes of Celsior solution supplemented with diazoxide (50, 100, 150, 200, and 250 ml) every 2 h for 30 min each for a 10 h period. The effects on cardiomyocytes and vascular endothelial cell morphology and marker expression were compared to the immersion control group. Whereas an incomplete endothelial cell layer with disorganized connective tissue was observed in the control and 50, 100, and 150 ml intermittent perfusion groups, transmission electron microscopic analysis revealed a complete endothelial cell layer in the intima with an organized subendothelium. A perfusion volume-dependent increase in eNOS expression that coincided with a decrease in ET-1, ICAM-1, vWF, and P-selectin expression was detected (all p < 0.01). Intermittent perfusion with 200 ml of Celsior solution every 2 h conferred protective effects simultaneously to the coronary arteries and myocardium on the porcine donor heart over a clinically relevant preservation period.
Collapse
|
16
|
Brant S, Rosenbaum D, Cobert M, West L, Jessen M, Peltz M. Effects of Antegrade and Retrograde Machine Perfusion Preservation on Cardiac Function After Transplantation in Canines. Transplant Proc 2014; 46:1601-5. [DOI: 10.1016/j.transproceed.2014.03.006] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2014] [Accepted: 03/12/2014] [Indexed: 11/16/2022]
|
17
|
Wszola M, Kwiatkowski A, Diuwe P, Domagała P, Górski L, Kieszek R, Berman A, Perkowska-Ptasińska A, Durlik M, Pączek L, Chmura A. One-year results of a prospective, randomized trial comparing two machine perfusion devices used for kidney preservation. Transpl Int 2013; 26:1088-96. [PMID: 24033725 DOI: 10.1111/tri.12169] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2013] [Revised: 02/23/2013] [Accepted: 07/21/2013] [Indexed: 02/03/2023]
Abstract
Studies have shown beneficial effects of machine perfusion (MP) on early kidney function and long-term graft survival. The aim of this study was to investigate whether the type of perfusion device could affect outcome of transplantation of deceased donor kidneys. A total of 50 kidneys retrieved from 25 donors were randomized to machine perfusion using a flow-driven (FD) device (RM3; Waters Medical Inc) or a pressure-driven (PD) device (LifePort; Organ Recovery Systems), 24 of these kidneys (n = 12 pairs; 48%) were procured from expanded criteria donors (ECD). The primary endpoints were kidney function after transplantation defined using the incidence of delayed graft function (DGF), the number of hemodialysis sessions required, graft function at 12 months, and analyses of biopsy. DGF was similar in both groups (32%; 8/25). Patients with DGF in the FD group required a mean of 4.66 hemodialysis sessions versus 2.65 in the PD group (P = 0.005). Overall, 1-year graft survival was 80% (20/25) vs. 96% (24/25) in the FD and PD groups. One-year graft survival of ECD kidneys was 66% (8/12) in the FD group versus 92% (11/12) in the PD group. Interstitial fibrosis and tubular atrophy were significantly more common in the FD group - 45% (5/11) vs. 0% (0/9) (P = 0.03) in PD group. There were no differences in creatinine levels between the groups. Machine perfusion using a pressure-driven device generating lower pulse stress is superior to a flow-driven device with higher pulse stress for preserving kidney function.
Collapse
Affiliation(s)
- Michal Wszola
- Department of General and Transplantation Surgery, Warsaw Medical University, Warsaw, Poland
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
18
|
Maeda M, Kasahara N, Doi J, Iijima Y, Kikuchi T, Teratani T, Kobayashi E. A luminance-based heart chip assay for assessing the efficacy of graft preservation solutions in heart transplantation in rats. HEART ASIA 2013; 5:7-14. [PMID: 23585802 PMCID: PMC3622429 DOI: 10.1136/heartasia-2012-010160] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 08/01/2012] [Revised: 11/29/2012] [Accepted: 12/09/2012] [Indexed: 12/12/2022]
Abstract
Objective We developed a novel luciferase-based viability assay for assessing the viability of hearts preserved in different solutions. We examined whether this in vitro system could predict heart damage and survival after transplantation in rats. Design By our novel system, preserved heart viability evaluation and transplanted heart-graft functional research study. Setting University basic science laboratory. Interventions Isolated Luciferase-transgenic Lewis (LEW) rat cardiac-tissue-chips were plated on 96-well tissue-culture plates and incubated in preservation solutions at 4°C. Viability was measured as photon intensity by using a bio-imaging system. Heart-grafts preserved in University of Wisconsin (UW), extracellular-trehalose-Kyoto (ETK), Euro-Collins (EC), histidin-tryptophan-ketoglutarat solution (HTK), lactated Ringer's (LR) or normal saline solution were transplanted cervically by using a cuff-technique or into the abdomens of syngeneic wild-type LEW rats by using conventional microsurgical suture techniques. Main outcome measures Imaging an evaluation of preservation heart-graft and functional analysis. Results Cardiac-tissue-chips preserved with UW, HTK or ETK solution gave higher luminance than those preserved with EC, LR or normal saline (p<0.03). After 24 h of preservation of hearts in each solution at 4°C, the beating of the isolated hearts was evaluated. The success rate, evaluation of beating, of cervical heart transplants using UW and ETK solution exceeded 70%, but those using other preservation solutions were lower (UW: 100%, ETK: 75%, EC: 42.86%, HTK: 14.29%, normal saline: 0%). Histological analysis of cervical heart-grafts after 3 h preservation by myeloperoxidase (MPO), zona occludens-1(ZO-1), and caspase-3 immunostaining revealed different degrees of preservation damage in all grafts. Conclusions Our novel assay system is simple and can test multiple solutions. It should therefore be a powerful tool for developing and improving new heart-graft preservation solutions.
Collapse
Affiliation(s)
- Masashi Maeda
- Division of Development of Advanced Therapy , Center for Development of Advanced Medical Technology, Jichi Medical University , Tochigi , Japan
| | | | | | | | | | | | | |
Collapse
|
19
|
Balfoussia D, Yerrakalva D, Hamaoui K, Papalois V. Advances in machine perfusion graft viability assessment in kidney, liver, pancreas, lung, and heart transplant. EXP CLIN TRANSPLANT 2012; 10:87-100. [PMID: 22432750 DOI: 10.6002/ect.2011.0167] [Citation(s) in RCA: 34] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
Solid organ transplant constitutes the definitive treatment for end-stage organ failure. Better organ preservation methods have enabled use of marginal grafts, thereby expanding the donor pool to meet the growing demand for organs. Static cold storage as a preservation method has been superseded largely by machine perfusion in kidney transplant, with work regarding its use in other organ transplants ongoing. We hope that machine perfusion will allow better graft preservation, and pretransplant assessment, and optimization. The most extensive laboratory, preclinical, and clinical research into machine perfusion organ preservation has focused on kidneys. Successful outcomes in its use in renal transplant have sparked interest for its development and application to the liver, pancreas, heart, and lungs. This article reviews the current state of machine perfusion in abdominal and thoracic organ transplant, focusing on the recent developments in assessing graft viability.
Collapse
Affiliation(s)
- Danai Balfoussia
- West London Renal and Transplant Centre, Hammersmith Hospital, Du Cane Road, London, W12 OHS, UK
| | | | | | | |
Collapse
|
20
|
Differences in Regional Myocardial Perfusion, Metabolism, MVO2, and Edema After Coronary Sinus Machine Perfusion Preservation of Canine Hearts. ASAIO J 2011; 57:481-6. [DOI: 10.1097/mat.0b013e31823769d5] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022] Open
|