1
|
Kurachi T, Chuman S, Suzuki T, Kubota T, Ishikawa S. Effects of aerosols from heated tobacco products with flavors on the discoloration of bovine tooth enamel. Clin Exp Dent Res 2023; 9:1069-1077. [PMID: 37438937 PMCID: PMC10728517 DOI: 10.1002/cre2.764] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/25/2022] [Revised: 03/31/2023] [Accepted: 06/22/2023] [Indexed: 07/14/2023] Open
Abstract
OBJECTIVES This in vitro study assessed the potential of tooth discoloration by aerosols generated from three heated tobacco products (HTPs) with different specifications: in-direct heating tobacco system platform 1.0a (IT1.0a), in-direct heating tobacco system platform 2.0a (IT2.0a), and direct heating tobacco system platform 3.0a (DT3.0a). In addition, three flavor types (regular, menthol, and berry menthol) were selected for each HTP to characterize the effect of flavor types on tooth discoloration. MATERIAL AND METHODS Six bovine tooth samples were exposed directly to aerosols generated from one pack of each HTP: 350 puffs for IT1.0a, 325 puffs for IT2.0a, and 220 puffs for DT3.0a. Six bovine tooth samples were also exposed to air (350 puffs) and smoke generated from one pack of cigarettes (160 puffs) as negative and positive controls, respectively. The color of each tooth sample was measured before and after exposure. The overall color changes were assessed using overall color differences (ΔE) calculated according to the Commission International de I'Eclairage color system. A one-way analysis of variance followed by Tukey's post hoc test was used to compare ΔE among bovine tooth samples exposed to air, cigarette smoke, and aerosols generated from each HTP. RESULTS ΔE values for tooth samples exposed to air and aerosols generated from the three HTPs (IT1.0a, IT2.0a, and DT3.0a) were significantly lower than ΔE value for tooth samples exposed to cigarette smoke. ΔE values obtained with DT3.0a were significantly higher than those obtained with air-exposed control samples. However, ΔE values obtained with IT1.0a and IT2.0a were not significantly different from that obtained with air-exposed control samples. No HTPs showed significant differences in ΔE values among the three flavor types. CONCLUSIONS This study showed that HTP aerosols reduce tooth discoloration potential compared with cigarette smoke, regardless of flavor types, and the tooth discoloration potential of the product may depend on product specifications.
Collapse
Affiliation(s)
- Takeshi Kurachi
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc.YokohamaKanagawaJapan
| | - Shinnosuke Chuman
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc.YokohamaKanagawaJapan
| | - Takuya Suzuki
- Scientific and Regulatory Affairs, JT International SAGenevaSwitzerland
| | | | - Shinkichi Ishikawa
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc.YokohamaKanagawaJapan
| |
Collapse
|
2
|
Bedford R, Smith G, Rothwell E, Martin S, Medhane R, Casentieri D, Daunt A, Freiberg G, Hollings M. A multi-organ, lung-derived inflammatory response following in vitro airway exposure to cigarette smoke and next-generation nicotine delivery products. Toxicol Lett 2023; 387:35-49. [PMID: 37774809 DOI: 10.1016/j.toxlet.2023.09.010] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/23/2023] [Revised: 09/08/2023] [Accepted: 09/26/2023] [Indexed: 10/01/2023]
Abstract
Despite increasing use of in vitro models that closely resemble in vivo human biology, their application in understanding downstream effects of airway toxicity, such as inflammation, are at an early stage. In this study, we used various assays to examine the inflammatory response induced in MucilAir™ tissues and A549 cells exposed to three products known to induce toxicity. Reduced barrier integrity was observed in tissues following exposure to each product, with reduced viability and increased cytotoxicity also shown. Similar changes in viability were also observed in A549 cells. Furthermore, whole cigarette smoke (CS) induced downstream phenotypic THP-1 changes and endothelial cell adhesion, an early marker of atherosclerosis. In contrast, exposure to next-generation delivery product (NGP) aerosol did not induce this response. Cytokine, histological and RNA analysis highlighted increased biomarkers linked to inflammatory pathways and immune cell differentiation following exposure to whole cigarette smoke, including GM-CSF, IL-1β, cleaved caspase-3 and cytochrome P450 enzymes. As a result of similar observations in human airway inflammation, we propose that our exposure platform could act as a representative model for studying such events in vitro. Furthermore, this model could be used to test the inflammatory or anti-inflammatory impact posed by inhaled compounds delivered to the lung.
Collapse
Affiliation(s)
- R Bedford
- Labcorp Early Development Laboratories Limited, Harrogate, UK.
| | - G Smith
- Labcorp Early Development Laboratories Limited, Harrogate, UK
| | - E Rothwell
- Labcorp Early Development Laboratories Limited, Harrogate, UK
| | - S Martin
- Labcorp Early Development Laboratories Limited, Harrogate, UK
| | - R Medhane
- Labcorp Early Development Laboratories Limited, Harrogate, UK
| | - D Casentieri
- Labcorp Early Development Laboratories Limited, Harrogate, UK
| | - A Daunt
- Labcorp Early Development Laboratories Limited, Harrogate, UK
| | - G Freiberg
- Labcorp Early Development Laboratories Limited, Eye, UK
| | - M Hollings
- Labcorp Early Development Laboratories Limited, Harrogate, UK.
| |
Collapse
|
3
|
Chemical and in vitro toxicological comparison of emissions from a heated tobacco product and the 1R6F reference cigarette. Toxicol Rep 2023; 10:281-292. [PMID: 36876026 PMCID: PMC9976195 DOI: 10.1016/j.toxrep.2023.02.005] [Citation(s) in RCA: 4] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2022] [Revised: 02/06/2023] [Accepted: 02/14/2023] [Indexed: 02/17/2023] Open
Abstract
It has previously been found that, compared with cigarette smoke, the aerosols generated by heated tobacco products contain fewer and lower harmful and potentially harmful constituents (HPHCs) and elicit lower biological activity in in vitro models and lower smoking-related exposure biomarker levels in clinical studies. It is important to accumulate such scientific evidences for heated tobacco products with a novel heating system, because different heating system may affect the quantitative aspect of the amount of HPHCs and the qualitative aspect of the biological activity of the aerosol generated. Here, the chemical properties of, and toxicological responses to aerosols emitted by DT3.0a, a new heated tobacco product with a novel heating system, and cigarette smoke (CS) were compared, using chemical analyses, in vitro battery (standardized genotoxicity and cytotoxicity) assays, and mechanistic (ToxTracker and two-dimensional cell culture) assays. Regular- and menthol-flavored DT3.0a and standard 1R6F reference cigarettes were tested. Selected HPHC yields were lower in DT3.0a aerosol than 1R6F CS. The genotoxicity-related assays indicated that DT3.0a aerosol was not genotoxic, regardless of metabolic activation. The other biological assays indicated that less cytotoxicity induction and oxidative stress response were elicited by DT3.0a aerosol compared with 1R6F CS. Similar results were found for both regular and menthol DT3.0a. Like previous reports for heated tobacco products with other heating systems, the results of this study indicated that DT3.0a aerosols have chemical and biological properties less likely to be harmful than 1R6F CS.
Collapse
Key Words
- ACM, aerosol collected mass
- ARE, anti-oxidant responsive element
- AqE, aqueous extract
- BDL, below detection limit
- CMF-PBS, calcium- and magnesium-free phosphate buffered saline
- CS, cigarette smoke
- Cytotoxicity
- DT3.0a, Direct Heating Tobacco System Platform 3 generation 3 version a
- GFP, green fluorescent protein
- GVP, gas-vapor phase
- Genotoxicity
- HPHCs
- HPHCs, harmful and potentially harmful constituents
- HTP, heated tobacco product
- Heated tobacco product
- IC50, half maximal inhibitory concentration
- ISO, International Organization for Standardization
- In vitro
- LOD, limit of detection
- LOQ, limit of quantification
- MLA, mouse lymphoma assay
- MN, micronucleus
- MRTP, modified risk tobacco product
- NQ, not quantified
- NRU, neutral red uptake
- Oxidative stress
- ROS, reactive oxygen species
- THP, tobacco heating product
- THS, tobacco heating system
- TPM, total particulate matter
- mES, mouse embryonic stem
Collapse
|
4
|
Miyauchi M, Ishikawa S, Kurachi T, Sakamoto K, Sakai H. Oral Absorption across Organotypic Culture Models of the Human Buccal Epithelium after E-cigarette Aerosol Exposure. ACS OMEGA 2022; 7:45574-45581. [PMID: 36530294 PMCID: PMC9753183 DOI: 10.1021/acsomega.2c06304] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/29/2022] [Accepted: 11/21/2022] [Indexed: 06/17/2023]
Abstract
Inhaled aerosols are absorbed across the oral cavity, respiratory tract, and gastrointestinal tract. The absorption across the oral cavity, which is one of the exposure routes, plays an important role in understanding pharmacokinetics and physiological effects. After aerosol exposure from e-cigarettes, tissue viability studies, morphological observation, and chemical analyses at the inner and outer buccal tissues were performed using organotypic 3D in vitro culture models of the buccal epithelium to better understand the deposition and absorption on the inner and outer buccal tissues. The aerosol exposures did not affect the tissue viability and had no change to the tissue morphology and structure. The deposition ratio at the buccal tissue surface is relatively low. This shows that majority of aerosol transfers to the airway tissues. The distribution from the inner tissue to the outer tissue has selectivity among various compounds, depending on the affinity with the liquid crystal structure of phospholipids and glucosylceramide. Although nicotine absorption in the aqueous solution was well known to increase as the unprotonated state of nicotine increased, the nicotine absorption after the aerosol exposure is irrelevant to the protonated-unprotonated state. Furthermore, the results showed that half of nicotine that adhered to the oral cavity transferred to the inner tissue via the oral epithelium and the other half transferred to the gastrointestinal tract accompanying multiple executions of swallowing, while majority of the water-soluble compounds with the hydroxyl group such as propylene glycol and benzoic acid that adhered to the oral cavity were eluted with the saliva and transferred to the gastrointestinal tract by swallowing.
Collapse
Affiliation(s)
- Masato Miyauchi
- Tobacco
Science Research Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba, Yokohama, Kanagawa 227-8512, Japan
| | - Shinkichi Ishikawa
- Scientific
Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba, Yokohama, Kanagawa 227-8512, Japan
| | - Takeshi Kurachi
- Scientific
Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba, Yokohama, Kanagawa 227-8512, Japan
| | - Kazutami Sakamoto
- Department
of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan
| | - Hideki Sakai
- Department
of Pure and Applied Chemistry, Faculty of Science and Technology, Tokyo University of Science, 2641 Yamazaki, Noda, Chiba 278-8510, Japan
| |
Collapse
|
5
|
Mori S, Ishimori K, Matsumura K, Ishikawa S, Ito S. Donor-to-donor variability of a human three-dimensional bronchial epithelial model: A case study of cigarette smoke exposure. Toxicol In Vitro 2022; 82:105391. [PMID: 35595035 DOI: 10.1016/j.tiv.2022.105391] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Revised: 04/21/2022] [Accepted: 05/13/2022] [Indexed: 01/05/2023]
Abstract
Three-dimensional (3D) cultured primary cells are used to predict the toxicity of substances towards humans because these 3D cultures closely mimic the physiological architecture of tissues. Nonetheless, it is important to consider primary-cell-specific variability for endpoint selection and appropriate evaluation of toxicity because donor-dependent characteristics may be retained even in in vitro cell cultures. In this report, 3D differentiated bronchial epithelial cells from three donors were used to investigate donor-to-donor variability, with an aqueous extract of cigarette smoke (CS) used as the test substance. Ciliary function, cytokine secretion, and histopathology, which are affected by CS, were examined, and transcriptomic analysis was also performed. The results revealed that interleukin-8 secretion and oxidative stress-related gene expression were consistently altered for all donors; however, their amplitudes varied. Moreover, one of the donors showed unique responses to CS, suggesting that this donor was an outlier. This donor showed intrinsic differences in histology, cytokine secretion, and gene expression profile. Such donors may help evaluate potential toxicological concerns and aid our understanding of disease pathogenesis. Conversely, these donors may confound toxicological assessment and endpoint selection. Fit-for-purpose handling of inter-donor variability is warranted.
Collapse
Affiliation(s)
- Sakura Mori
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan
| | - Kanae Ishimori
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan
| | - Kazushi Matsumura
- Scientific and Regulatory Affairs, JT International SA, 8 rue Kazem Radjavi, 1202 Geneva, Switzerland
| | - Shinkichi Ishikawa
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan
| | - Shigeaki Ito
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan.
| |
Collapse
|
6
|
Zhang J, Doshi U, Wolz RL, Kosachevsky P, Oldham MJ, Gillman IG, Lee KM. Fit-for-purpose characterization of air-liquid-interface (ALI) in vitro exposure systems for e-vapor aerosol. Toxicol In Vitro 2022; 82:105352. [PMID: 35341918 DOI: 10.1016/j.tiv.2022.105352] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2021] [Revised: 03/03/2022] [Accepted: 03/18/2022] [Indexed: 11/28/2022]
Abstract
Air-liquid-interface (ALI) exposure systems deliver aerosol to the apical surface of cells which mimics the in vivo inhalation exposure conditions. It is necessary, however, to quantify the delivered amount of aerosol for ALI-based in vitro toxicity assessment. In this study, we evaluated two commercially available ALI exposure systems, a Vitrocell® Ames 48 (Ames 48) and a Vitrocell® 24/48 (VC 24/48), and the Vitrocell® VC1/7 smoking machine using a cig-a-like cartridge-based e-vapor device with a prototype formulation (containing 4% nicotine by weight). We characterized aerosol particle-size distribution, aerosol mass, and major chemical components (nicotine, propylene glycol, and glycerol) at the generation source and verified the repeatability of the aerosol generation. We determined aerosol delivery at the ALI by gravimetric analysis of mass collected on Cambridge filter pads and analytical quantitation of the buffer medium which showed that both aerosol mass and nicotine to an exposure insert linearly increased up to 400 puffs. The delivered aerosol mass covered a wide range of 0.8-3.4 mg per insert in the Ames 48 with variability (relative standard deviation, RSD) up to 12% and 1.1-6.4 mg per insert in the VC 24/48 with variability up to 15%. The delivered nicotine ranged approximately up to 200 μg per insert in both exposure systems. These results provided operation and aerosol delivery information of these ALI exposure systems for subsequent in vitro testing of e-vapor aerosols.
Collapse
Affiliation(s)
- J Zhang
- Altria Client Services LLC, Richmond, VA, United States of America.
| | - U Doshi
- Altria Client Services LLC, Richmond, VA, United States of America
| | - R L Wolz
- Enthalpy Analytical, Richmond, VA, United States of America
| | - P Kosachevsky
- Enthalpy Analytical, Richmond, VA, United States of America
| | - M J Oldham
- Altria Client Services LLC, Richmond, VA, United States of America
| | - I G Gillman
- Enthalpy Analytical, Richmond, VA, United States of America; Enthalpy Analytical, Richmond, VA, United States of America
| | - K M Lee
- Altria Client Services LLC, Richmond, VA, United States of America
| |
Collapse
|
7
|
Bedford R, Perkins E, Clements J, Hollings M. Recent advancements and application of in vitro models for predicting inhalation toxicity in humans. Toxicol In Vitro 2021; 79:105299. [PMID: 34920082 DOI: 10.1016/j.tiv.2021.105299] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/22/2021] [Revised: 11/20/2021] [Accepted: 12/10/2021] [Indexed: 12/01/2022]
Abstract
Animals have been indispensable in testing chemicals that can pose a risk to human health, including those delivered by inhalation. In recent years, the combination of societal debate on the use of animals in research and testing, the drive to continually enhance testing methodologies, and technology advancements have prompted a range of initiatives to develop non-animal alternative approaches for toxicity testing. In this review, we discuss emerging in vitro techniques being developed for the testing of inhaled compounds. Advanced tissue models that are able to recreate the human response to toxic exposures alongside examples of their ability to complement in vivo techniques are described. Furthermore, technology being developed that can provide multi-organ toxicity assessments are discussed.
Collapse
Affiliation(s)
- R Bedford
- Labcorp Early Development Laboratories Limited, Harrogate, UK.
| | - E Perkins
- Labcorp Early Development Laboratories Limited, Harrogate, UK.
| | - J Clements
- Labcorp Early Development Laboratories Limited, Harrogate, UK.
| | - M Hollings
- Labcorp Early Development Laboratories Limited, Harrogate, UK.
| |
Collapse
|
8
|
Nishino K, Tamai K, Orita K, Hashimoto Y, Nakamura H. Heated Tobacco Products Impair Cell Viability, Osteoblastic Differentiation, and Bone Fracture-Healing. J Bone Joint Surg Am 2021; 103:2024-2031. [PMID: 34730563 DOI: 10.2106/jbjs.20.02227] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 02/01/2023]
Abstract
BACKGROUND The negative impact of cigarette smoking on bone union has been well documented. However, the impact of heated tobacco product (HTP) use on bone fracture-healing remains unclear. The present study investigated the effect of HTPs on preosteoblast viability, osteoblastic differentiation, and fracture-healing and compared the effects with those of conventional combustible cigarettes. METHODS Cigarette smoke extracts (CSEs) were generated from combustible cigarettes (cCSE) and HTPs (hCSE). CSE concentrations were standardized by assessing optical density. Preosteoblast (MC3T3-E1) cells were incubated with normal medium, cCSE, or hCSE. The cell viability was assessed via MTT assay. After osteoblastic differentiation of CSE-exposed cells, alkaline phosphatase (ALP) activity was assessed. To assess the in vivo effects of CSEs, a femoral midshaft osteotomy was performed in a rat model; thereafter, saline solution, cCSE, or hCSE was injected intraperitoneally, and bone union was assessed on the basis of micro-computed tomography (μCT) and biomechanical analysis 4 weeks later. RESULTS MC3T3-E1 cell viability was reduced in a time and concentration-dependent manner when treated with either cCSE or hCSE. ALP activity after osteoblastic differentiation of cCSE-treated cells was significantly lower than that of both untreated and hCSE-treated cells (mean and standard deviation, 452.4 ± 48.8 [untreated], 326.2 ± 26.2 [cCSE-treated], and 389.9 ± 26.6 [hCSE-treated] mol/L/min; p = 0.002). Moreover, the levels of osteoblastic differentiation in untreated and hCSE-treated cells differed significantly (p < 0.05). In vivo assessment of the femoral midshaft cortical region revealed that both cCSE and hCSE administration significantly decreased bone mineral content 4 weeks after surgery compared with levels observed in untreated animals (107.0 ± 11.9 [untreated], 94.5 ± 13.0 [cCSE-treated], and 89.0 ± 10.1 mg/cm3 [hCSE-treated]; p = 0.049). Additionally, cCSE and hCSE-exposed femora had significantly lower bone volumes than unexposed femora. Biomechanical analyses showed that both cCSE and hCSE administration significantly decreased femoral maximum load and elastic modulus (p = 0.015 and 0.019). CONCLUSIONS HTP use impairs cell viability, osteoblastic differentiation, and bone fracture-healing at levels comparable with those associated with combustible cigarette use. CLINICAL RELEVANCE HTP use negatively affects bone fracture-healing to a degree similar to that of combustible cigarettes. Orthopaedic surgeons should recommend HTP smoking cessation to improve bone union.
Collapse
Affiliation(s)
- Kazuya Nishino
- Department of Orthopedics, Osaka City University Graduate School of Medicine, Osaka, Japan
| | | | | | | | | |
Collapse
|
9
|
Primavessy D, Metz J, Schnur S, Schneider M, Lehr CM, Hittinger M. Pulmonary in vitro instruments for the replacement of animal experiments. Eur J Pharm Biopharm 2021; 168:62-75. [PMID: 34438019 DOI: 10.1016/j.ejpb.2021.08.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/07/2021] [Revised: 07/19/2021] [Accepted: 08/17/2021] [Indexed: 11/16/2022]
Abstract
Advanced in vitro systems often combine a mechanical-physical instrument with a biological component e.g. cell culture models. For testing of aerosols, it is of advantage to consider aerosol behavior, particle deposition and lung region specific cell lines. Although there are many good reviews on the selection of cell cultures, articles on instruments are rare. This article focuses on the development of in vitro instruments targeting the exposure of aerosols on cell cultures. In this context, guidelines for toxicity investigation are taken into account as the aim of new methods must be the prediction of human relevant data and the replacement of existing animal experiments. We provide an overview on development history of research-based instruments from a pharmaceutical point of view. The standardized commercial devices resulting from the research-based instruments are presented and the future perspectives on pulmonary in vitro devices are discussed.
Collapse
Affiliation(s)
- Daniel Primavessy
- Department of Drug Delivery, PharmBioTec Research and Development GmbH, Saarbrücken, Germany.
| | - Julia Metz
- Department of Drug Delivery, PharmBioTec Research and Development GmbH, Saarbrücken, Germany
| | - Sabrina Schnur
- Department of Drug Delivery, PharmBioTec Research and Development GmbH, Saarbrücken, Germany; Department of Pharmacy, Biopharmaceutics and Pharmaceutical Technology, Saarland University, Saarbrücken, Germany
| | - Marc Schneider
- Department of Pharmacy, Biopharmaceutics and Pharmaceutical Technology, Saarland University, Saarbrücken, Germany
| | - Claus-Michael Lehr
- Department of Drug Delivery, PharmBioTec Research and Development GmbH, Saarbrücken, Germany; Department of Pharmacy, Biopharmaceutics and Pharmaceutical Technology, Saarland University, Saarbrücken, Germany; Helmholtz Institute for Pharmaceutical Research Saarland (HIPS), Saarbrücken, Germany
| | - Marius Hittinger
- Department of Drug Delivery, PharmBioTec Research and Development GmbH, Saarbrücken, Germany; 3RProducts Marius Hittinger, Blieskastel, Germany
| |
Collapse
|
10
|
Nossa R, Costa J, Cacopardo L, Ahluwalia A. Breathing in vitro: Designs and applications of engineered lung models. J Tissue Eng 2021; 12:20417314211008696. [PMID: 33996022 PMCID: PMC8107677 DOI: 10.1177/20417314211008696] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/21/2020] [Accepted: 03/22/2021] [Indexed: 12/11/2022] Open
Abstract
The aim of this review is to provide a systematic design guideline to users, particularly engineers interested in developing and deploying lung models, and biologists seeking to identify a suitable platform for conducting in vitro experiments involving pulmonary cells or tissues. We first discuss the state of the art on lung in vitro models, describing the most simplistic and traditional ones. Then, we analyze in further detail the more complex dynamic engineered systems that either provide mechanical cues, or allow for more predictive exposure studies, or in some cases even both. This is followed by a dedicated section on microchips of the lung. Lastly, we present a critical discussion of the different characteristics of each type of system and the criteria which may help researchers select the most appropriate technology according to their specific requirements. Readers are encouraged to refer to the tables accompanying the different sections where comprehensive and quantitative information on the operating parameters and performance of the different systems reported in the literature is provided.
Collapse
|
11
|
Optimizations of In Vitro Mucus and Cell Culture Models to Better Predict In Vivo Gene Transfer in Pathological Lung Respiratory Airways: Cystic Fibrosis as an Example. Pharmaceutics 2020; 13:pharmaceutics13010047. [PMID: 33396283 PMCID: PMC7823756 DOI: 10.3390/pharmaceutics13010047] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/01/2020] [Revised: 12/22/2020] [Accepted: 12/28/2020] [Indexed: 11/17/2022] Open
Abstract
The respiratory epithelium can be affected by many diseases that could be treated using aerosol gene therapy. Among these, cystic fibrosis (CF) is a lethal inherited disease characterized by airways complications, which determine the life expectancy and the effectiveness of aerosolized treatments. Beside evaluations performed under in vivo settings, cell culture models mimicking in vivo pathophysiological conditions can provide complementary insights into the potential of gene transfer strategies. Such models must consider multiple parameters, following the rationale that proper gene transfer evaluations depend on whether they are performed under experimental conditions close to pathophysiological settings. In addition, the mucus layer, which covers the epithelial cells, constitutes a physical barrier for gene delivery, especially in diseases such as CF. Artificial mucus models featuring physical and biological properties similar to CF mucus allow determining the ability of gene transfer systems to effectively reach the underlying epithelium. In this review, we describe mucus and cellular models relevant for CF aerosol gene therapy, with a particular emphasis on mucus rheology. We strongly believe that combining multiple pathophysiological features in single complex cell culture models could help bridge the gaps between in vitro and in vivo settings, as well as viral and non-viral gene delivery strategies.
Collapse
|
12
|
Ween MP, Moshensky A, Thredgold L, Bastian NA, Hamon R, Badiei A, Nguyen PT, Herewane K, Jersmann H, Bojanowski CM, Shin J, Reynolds PN, Crotty Alexander LE, Hodge SJ. E-cigarettes and health risks: more to the flavor than just the name. Am J Physiol Lung Cell Mol Physiol 2020; 320:L600-L614. [PMID: 33295836 DOI: 10.1152/ajplung.00370.2020] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
The growing interest in regulating flavored E-liquids must incorporate understanding of the "flavoring profile" of each E-liquid-which flavorings (flavoring chemicals) are present and at what concentrations not just focusing on the flavor on the label. We investigated the flavoring profile of 10 different flavored E-liquids. We assessed bronchial epithelial cell viability and apoptosis, phagocytosis of bacteria and apoptotic cells by macrophages after exposure to E-cigarette vapor extract (EVE). We validated our data in normal human bronchial epithelial cells (NHBE) and alveolar macrophages (AM) from healthy donors. We also assessed cytokine release and validated in the saliva from E-cigarette users. Increased necrosis/apoptosis (16.1-64.5% apoptosis) in 16HBE cells was flavor dependent, and NHBEs showed an increased susceptibility to flavors. In THP-1 differentiated macrophages phagocytosis was also flavor dependent, with AM also showing increased susceptibility to flavors. Further, Banana and Chocolate were shown to reduce surface expression of phagocytic target recognition receptors on alveolar macrophages. Banana and Chocolate increased IL-8 secretion by NHBE, whereas all 4 flavors reduced AM IL-1β secretion, which was also reduced in the saliva of E-cigarette users compared with healthy controls. Flavorant profiles of E-liquids varied from simple 2 compound mixtures to complex mixtures containing over a dozen flavorants. E-liquids with high benzene content, complex flavoring profiles, high chemical concentration had the greatest impacts. The Flavorant profile of E-liquids is key to disruption of the airway status quo by increasing bronchial epithelial cell apoptosis, causing alveolar macrophage phagocytic dysfunction, and altering airway cytokines.
Collapse
Affiliation(s)
- M P Ween
- Department of Thoracic Medicine, Royal Adelaide Hospital, Adelaide, South Australia, Australia.,School of Medicine, University of Adelaide, Adelaide, South Australia, Australia
| | - A Moshensky
- Pulmonary Critical Care Section, Veterans Affairs San Diego Healthcare System, San Diego, California.,Division of Pulmonary, Critical Care and Sleep Medicine, University of California San Diego, La Jolla, California
| | - L Thredgold
- Department of Occupational and Environmental Health, School of Public Health, University of Adelaide, Adelaide, South Australia, Australia
| | - N A Bastian
- Department of Thoracic Medicine, Royal Adelaide Hospital, Adelaide, South Australia, Australia.,School of Medicine, University of Adelaide, Adelaide, South Australia, Australia
| | - R Hamon
- Department of Thoracic Medicine, Royal Adelaide Hospital, Adelaide, South Australia, Australia.,Centre for Cancer Biology, SA Pathology and the University of South Australia, Adelaide, South Australia, Australia
| | - A Badiei
- Department of Thoracic Medicine, Royal Adelaide Hospital, Adelaide, South Australia, Australia
| | - P T Nguyen
- Department of Thoracic Medicine, Royal Adelaide Hospital, Adelaide, South Australia, Australia.,School of Medicine, University of Adelaide, Adelaide, South Australia, Australia
| | - K Herewane
- Department of Thoracic Medicine, Royal Adelaide Hospital, Adelaide, South Australia, Australia.,School of Medicine, University of Adelaide, Adelaide, South Australia, Australia
| | - H Jersmann
- Department of Thoracic Medicine, Royal Adelaide Hospital, Adelaide, South Australia, Australia.,School of Medicine, University of Adelaide, Adelaide, South Australia, Australia
| | - C M Bojanowski
- Pulmonary Critical Care Section, Veterans Affairs San Diego Healthcare System, San Diego, California.,Division of Pulmonary, Critical Care and Sleep Medicine, University of California San Diego, La Jolla, California
| | - J Shin
- Pulmonary Critical Care Section, Veterans Affairs San Diego Healthcare System, San Diego, California.,Division of Pulmonary, Critical Care and Sleep Medicine, University of California San Diego, La Jolla, California
| | - P N Reynolds
- Department of Thoracic Medicine, Royal Adelaide Hospital, Adelaide, South Australia, Australia.,School of Medicine, University of Adelaide, Adelaide, South Australia, Australia
| | - L E Crotty Alexander
- Pulmonary Critical Care Section, Veterans Affairs San Diego Healthcare System, San Diego, California.,Division of Pulmonary, Critical Care and Sleep Medicine, University of California San Diego, La Jolla, California
| | - S J Hodge
- School of Medicine, University of Adelaide, Adelaide, South Australia, Australia
| |
Collapse
|
13
|
Leibrock LB, Jungnickel H, Tentschert J, Katz A, Toman B, Petersen EJ, Bierkandt FS, Singh AV, Laux P, Luch A. Parametric Optimization of an Air-Liquid Interface System for Flow-Through Inhalation Exposure to Nanoparticles: Assessing Dosimetry and Intracellular Uptake of CeO 2 Nanoparticles. NANOMATERIALS (BASEL, SWITZERLAND) 2020; 10:E2369. [PMID: 33260672 PMCID: PMC7760223 DOI: 10.3390/nano10122369] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/03/2020] [Revised: 11/26/2020] [Accepted: 11/27/2020] [Indexed: 12/11/2022]
Abstract
Air-liquid interface (ALI) systems have been widely used in recent years to investigate the inhalation toxicity of many gaseous compounds, chemicals, and nanomaterials and represent an emerging and promising in vitro method to supplement in vivo studies. ALI exposure reflects the physiological conditions of the deep lung more closely to subacute in vivo inhalation scenarios compared to submerged exposure. The comparability of the toxicological results obtained from in vivo and in vitro inhalation data is still challenging. The robustness of ALI exposure scenarios is not yet well understood, but critical for the potential standardization of these methods. We report a cause-and-effect (C&E) analysis of a flow through ALI exposure system. The influence of five different instrumental and physiological parameters affecting cell viability and exposure parameters of a human lung cell line in vitro (exposure duration, relative humidity, temperature, CO2 concentration and flow rate) was investigated. After exposing lung epithelia cells to a CeO2 nanoparticle (NP) aerosol, intracellular CeO2 concentrations reached values similar to those found in a recent subacute rat inhalation study in vivo. This is the first study showing that the NP concentration reached in vitro using a flow through ALI system were the same as those in an in vivo study.
Collapse
Affiliation(s)
- Lars B. Leibrock
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Strasse 8-10, 10589 Berlin, Germany; (H.J.); (J.T.); (A.K.); (F.S.B.); (A.V.S.); (P.L.); (A.L.)
| | - Harald Jungnickel
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Strasse 8-10, 10589 Berlin, Germany; (H.J.); (J.T.); (A.K.); (F.S.B.); (A.V.S.); (P.L.); (A.L.)
| | - Jutta Tentschert
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Strasse 8-10, 10589 Berlin, Germany; (H.J.); (J.T.); (A.K.); (F.S.B.); (A.V.S.); (P.L.); (A.L.)
| | - Aaron Katz
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Strasse 8-10, 10589 Berlin, Germany; (H.J.); (J.T.); (A.K.); (F.S.B.); (A.V.S.); (P.L.); (A.L.)
| | - Blaza Toman
- Information Technology Laboratory, National Institute of Standards and Technology, 100 Bureau Drive, Gaitherburg, MD 20899-8311, USA;
| | - Elijah J. Petersen
- Materials Measurement Laboratory, National Institute of Standards and Technology, 100 Bureau Drive, Gaitherburg, MD 20899-8311, USA;
| | - Frank S. Bierkandt
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Strasse 8-10, 10589 Berlin, Germany; (H.J.); (J.T.); (A.K.); (F.S.B.); (A.V.S.); (P.L.); (A.L.)
| | - Ajay Vikram Singh
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Strasse 8-10, 10589 Berlin, Germany; (H.J.); (J.T.); (A.K.); (F.S.B.); (A.V.S.); (P.L.); (A.L.)
| | - Peter Laux
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Strasse 8-10, 10589 Berlin, Germany; (H.J.); (J.T.); (A.K.); (F.S.B.); (A.V.S.); (P.L.); (A.L.)
| | - Andreas Luch
- German Federal Institute for Risk Assessment (BfR), Department of Chemical and Product Safety, Max-Dohrn-Strasse 8-10, 10589 Berlin, Germany; (H.J.); (J.T.); (A.K.); (F.S.B.); (A.V.S.); (P.L.); (A.L.)
| |
Collapse
|
14
|
Matsumura K, Ito S. Novel biomarker genes which distinguish between smokers and chronic obstructive pulmonary disease patients with machine learning approach. BMC Pulm Med 2020; 20:29. [PMID: 32013930 PMCID: PMC6998147 DOI: 10.1186/s12890-020-1062-9] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/31/2019] [Accepted: 01/24/2020] [Indexed: 02/06/2023] Open
Abstract
Background Chronic obstructive pulmonary disease (COPD) is combination of progressive lung diseases. The diagnosis of COPD is generally based on the pulmonary function testing, however, difficulties underlie in prognosis of smokers or early stage of COPD patients due to the complexity and heterogeneity of the pathogenesis. Computational analyses of omics technologies are expected as one of the solutions to resolve such complexities. Methods We obtained transcriptomic data by in vitro testing with exposures of human bronchial epithelial cells to the inducers for early events of COPD to identify the potential descriptive marker genes. With the identified genes, the machine learning technique was employed with the publicly available transcriptome data obtained from the lung specimens of COPD and non-COPD patients to develop the model that can reflect the risk continuum across smoking and COPD. Results The expression levels of 15 genes were commonly altered among in vitro tissues exposed to known inducible factors for earlier events of COPD (exposure to cigarette smoke, DNA damage, oxidative stress, and inflammation), and 10 of these genes and their corresponding proteins have not previously reported as COPD biomarkers. Although these genes were able to predict each group with 65% accuracy, the accuracy with which they were able to discriminate COPD subjects from smokers was only 29%. Furthermore, logistic regression enabled the conversion of gene expression levels to a numerical index, which we named the “potential risk factor (PRF)” index. The highest significant index value was recorded in COPD subjects (0.56 at the median), followed by smokers (0.30) and non-smokers (0.02). In vitro tissues exposed to cigarette smoke displayed dose-dependent increases of PRF, suggesting its utility for prospective risk estimation of tobacco products. Conclusions Our experimental-based transcriptomic analysis identified novel genes associated with COPD, and the 15 genes could distinguish smokers and COPD subjects from non-smokers via machine-learning classification with remarkable accuracy. We also suggested a PRF index that can quantitatively reflect the risk continuum across smoking and COPD pathogenesis, and we believe it will provide an improved understanding of smoking effects and new insights into COPD.
Collapse
Affiliation(s)
- Kazushi Matsumura
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa, 227-8512, Japan.
| | - Shigeaki Ito
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa, 227-8512, Japan
| |
Collapse
|
15
|
Ito S, Taylor M, Mori S, Thorne D, Nishino T, Breheny D, Gaça M, Yoshino K, Proctor C. An inter-laboratory in vitro assessment of cigarettes and next generation nicotine delivery products. Toxicol Lett 2019; 315:14-22. [PMID: 31400404 DOI: 10.1016/j.toxlet.2019.08.004] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/11/2019] [Revised: 07/16/2019] [Accepted: 08/06/2019] [Indexed: 02/07/2023]
Abstract
In vitro testing can facilitate the rapid assessment of next generation nicotine delivery products (NGPs) with comparisons to combustible tobacco products. In vitro assays for cytotoxicity and oxidative stress were employed at BAT (UK) and JT (Japan) to test total particulate matter (TPM) of a scientific reference cigarette and aerosol collected mass (ACM) of a commercially available E-cigarette and two tobacco heating products (THP). 3R4F TPMs were generated using the Health Canada intense (HCI) regimen, a modified regime (mHCI) for the THP ACMs and the CORESTA recommended method no. 81 for the E-cigarette ACM. Human lung cells were exposed to the test product TPM/ACMs at concentrations between 0-200 μg/ml followed by the employment of commercially available assays for endpoint analysis that included reactive oxygen species (ROS) generation, the glutathione ratio (GSH:GSSG), activation of the antioxidant response elements (ARE) and cellular viability. TPM/ACM nicotine concentrations were quantified using a UPLC-PDA technique. At both laboratories the 3R4F TPM induced significant and dose-dependent responses in all in vitro assays, whereas no significant responses could be measured for the NGP ACMs. In conclusion, both laboratories obtained comparable results across all endpoints therefore demonstrating the utility of the in vitro techniques combined with standardised test products to support the assessment of NGPs.
Collapse
Affiliation(s)
| | - Mark Taylor
- British American Tobacco, R&D, Southampton, UK.
| | - Sakura Mori
- Japan Tobacco Inc., R&D Group, Yokohama, Japan
| | | | | | | | | | - Kei Yoshino
- Japan Tobacco Inc., R&D Group, Yokohama, Japan
| | | |
Collapse
|
16
|
Jaccard G, Djoko DT, Korneliou A, Stabbert R, Belushkin M, Esposito M. Mainstream smoke constituents and in vitro toxicity comparative analysis of 3R4F and 1R6F reference cigarettes. Toxicol Rep 2019; 6:222-231. [PMID: 30886823 PMCID: PMC6402302 DOI: 10.1016/j.toxrep.2019.02.009] [Citation(s) in RCA: 47] [Impact Index Per Article: 9.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2018] [Revised: 02/19/2019] [Accepted: 02/24/2019] [Indexed: 11/26/2022] Open
Abstract
3R4F Kentucky reference cigarettes stock is depleting. 3R4F reference cigarettes have been widely used as monitor or comparator. 1R6F reference cigarettes are a suitable replacement for 3R4F on the basis of smoke chemistry and in vitro assays.
A new Kentucky reference cigarette, 1R6F, has been manufactured to replace the depleting 3R4F reference cigarette. The 3R4F Kentucky reference cigarettes have been widely used as monitor or comparator cigarettes for mainstream smoke analysis and in vitro and in vivo toxicological data of cigarettes and novel tobacco products. Both reference cigarettes were analyzed in the same laboratory during the same period of time with the goal of performing a comparison of 3R4F and 1R6F. On the basis of the results obtained from aerosol chemistry and in vitro assays, we consider that the 1R6F reference cigarette is a suitable replacement for the 3R4F reference cigarette as a comparator/monitor cigarette. Its specific use as a comparator for novel tobacco products was checked on the basis of a comparative test with the Tobacco Heating System 2.2 as an example.
Collapse
Affiliation(s)
- Guy Jaccard
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 3, CH-2000, Neuchâtel, Switzerland
| | - Donatien Tafin Djoko
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 3, CH-2000, Neuchâtel, Switzerland
| | - Alexandra Korneliou
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 3, CH-2000, Neuchâtel, Switzerland
| | - Regina Stabbert
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 3, CH-2000, Neuchâtel, Switzerland
| | - Maxim Belushkin
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 3, CH-2000, Neuchâtel, Switzerland
| | - Marco Esposito
- PMI R&D, Philip Morris Products S.A., Quai Jeanrenaud 3, CH-2000, Neuchâtel, Switzerland
| |
Collapse
|
17
|
Ishikawa S, Matsumura K, Kitamura N, Takanami Y, Ito S. Multi-omics analysis: Repeated exposure of a 3D bronchial tissue culture to whole-cigarette smoke. Toxicol In Vitro 2019; 54:251-262. [PMID: 30291989 DOI: 10.1016/j.tiv.2018.10.001] [Citation(s) in RCA: 23] [Impact Index Per Article: 4.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/23/2018] [Revised: 08/09/2018] [Accepted: 10/01/2018] [Indexed: 02/02/2023]
Abstract
Cigarette smoke (CS) is a major risk factor in the development of chronic inflammatory lung diseases such as chronic obstructive pulmonary disease. A comprehensive investigation of the biological impacts of chronic CS exposure on lung tissue is therefore important for understanding the pathogenesis of lung disease. We used three-dimensional (3D) organotypic human bronchial tissue cultures and metabolomics, transcriptomics, and proteomics to investigate changes in biological processes affected by repeated whole-CS exposure. We found that CS perturbed central carbon metabolism in relation with oxidative stress responses. Epidermal growth factor receptor, which is involved in the early-stage pathogenesis of airway diseases, was identified as a key regulator of the perturbed processes. Proteomic analysis of proteins in the apical surface liquid of the 3D bronchial tissue cultures indicated that repeated whole-CS exposure induced alterations in the secretion of several known biomarkers of airway diseases, including mucins and matrix metalloproteinases. These findings are consistent with observations from lung disease patients. Overall, our results suggest that 3D bronchial tissue cultures can provide valuable information on tissue-specific alterations in biological processes induced by chronic exposure to CS.
Collapse
Affiliation(s)
- Shinkichi Ishikawa
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan.
| | - Kazushi Matsumura
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan.
| | - Nobumasa Kitamura
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan.
| | - Yuichiro Takanami
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan.
| | - Shigeaki Ito
- Scientific Product Assessment Center, R&D Group, Japan Tobacco Inc., 6-2 Umegaoka, Aoba-ku, Yokohama, Kanagawa 227-8512, Japan.
| |
Collapse
|
18
|
Pieper E, Mallock N, Henkler-Stephani F, Luch A. ["Heat not burn" tobacco devices as new tobacco industry products: health risks]. Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz 2018; 61:1422-1428. [PMID: 30284624 DOI: 10.1007/s00103-018-2823-y] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
Increased tobacco control measures in recent years have directed the tobacco industry to develop alternative tobacco products, such as "heat not burn" (HnB) tobacco devices that are implied to be less hazardous than conventional cigarettes. There are extensive studies from manufacturers available, which show that the emissions of HnB tobacco devices have significantly lower levels of harmful substances compared to conventional cigarettes. In addition, manufacturers have published studies to investigate whether switching from a conventional tobacco cigarette to the HnB product reduces possible health risks.The purpose of this report is to review current studies by manufacturers and independent institutions as well as to discuss possible reduced health hazards.The German Federal Institute for Risk Assessment (BfR) has carried out its own studies of selected analytes in the emissions of one HnB product confirming the lower levels of harmful substances in the emissions. The results are consistent with data from other independent studies. The nicotine content in the emissions is in the same range as the nicotine emissions of conventional cigarettes, which suggests a comparable addictiveness and dependence potential. Manufacturers have reported mutagenic effects of emissions by HnB tobacco devices that, however, are considerably weaker compared to conventional cigarettes. Nevertheless, the use of the HnB tobacco product remains associated with health risks.Switching from conventional cigarettes to tobacco heaters can significantly reduce the consumer's exposure to harmful substances. However, this article also illustrates that it is still unclear to what extent the reduced levels lead to lowered health risks. Therefore more independent studies, but also long-term studies, are needed.
Collapse
Affiliation(s)
- Elke Pieper
- Abteilung Chemikalien- und Produktsicherheit, Bundesinstitut für Risikobewertung (BfR), Max-Dohrn-Str. 8-10, 10589, Berlin, Deutschland.
| | - Nadja Mallock
- Abteilung Chemikalien- und Produktsicherheit, Bundesinstitut für Risikobewertung (BfR), Max-Dohrn-Str. 8-10, 10589, Berlin, Deutschland
| | - Frank Henkler-Stephani
- Abteilung Chemikalien- und Produktsicherheit, Bundesinstitut für Risikobewertung (BfR), Max-Dohrn-Str. 8-10, 10589, Berlin, Deutschland
| | - Andreas Luch
- Abteilung Chemikalien- und Produktsicherheit, Bundesinstitut für Risikobewertung (BfR), Max-Dohrn-Str. 8-10, 10589, Berlin, Deutschland
| |
Collapse
|