1
|
Arambula AM, Piper R, Murray G, Mowry SE, Rivas A, Semaan M, Manzoor NF, Killeen DE, Kelsall DC, Lupo JE, Biever A, Stidham KR, Albinus R, Morgan S, Kaplan BJ, Presley R, Menendez S, Tejani VD. Sensitivity and Specificity of Intraoperative TransImpedance Matrix Recordings Compared With X-ray Imaging in Detecting Perimodiolar Cochlear Implant Tip Foldovers: A Multicenter Study. Otol Neurotol 2025:00129492-990000000-00784. [PMID: 40210225 DOI: 10.1097/mao.0000000000004502] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/12/2025]
Abstract
OBJECTIVE Characterize the sensitivity and specificity of TransImpedance Matrix (TIM) recordings compared with x-rays in detecting cochlear implant tip foldovers. STUDY DESIGN Retrospective. SETTING Multi-institutional, academic and private surgery centers. PATIENTS Patients 6 months and older undergoing cochlear implantation. INTERVENTIONS After cochlear implant array insertion, intraoperative TIM recordings and x-rays were conducted to confirm appropriate placement. If a foldover was identified, repeat insertion, followed by TIM and x-ray, was performed. MAIN OUTCOME MEASURES Presence of tip foldovers as determined by TIM recordings and x-rays. RESULTS There were 13 tip foldovers out of 484 insertions, yielding a 2.7% tip foldover rate. Using x-rays as the "gold standard," TIM recordings showed 100% sensitivity, 99.6% specificity, 84.6% positive predictive value (PPV), and 100% negative predicative value in detecting tip foldovers. The x-ray images for two TIM-identified tip foldovers were interpreted as normal intraoperatively (apparent false positives), but then were interpreted as foldovers when presented to the operating surgeon postoperatively in a blinded fashion. If these false positives had been reclassified as true positives, TIM specificity and PPV would both improve to 100%. CONCLUSIONS These results provide further support regarding the utility of TIM recordings to evaluate appropriate cochlear implant electrode array position. Despite the low tip foldover rate reported across the literature and within this study, this multicenter patient group provided a large sample size to calculate the sensitivity and specificity of TIM recordings in identifying tip foldovers. Compared with the reference-standard, x-ray imaging, TIM recordings show equivalent, and in some cases superior, performance in identification of tip foldovers. Thus, use of TIM can potentially preclude the need for routine intraoperative x-rays without compromising patient care.
Collapse
Affiliation(s)
| | | | | | | | | | | | - Nauman F Manzoor
- Department of Otolaryngology-Head and Neck Surgery, Virginia Commonwealth University, Richmond, Virginia
| | | | | | - J Eric Lupo
- Rocky Mountain Ear Center, Englewood, Colorado
| | | | | | | | | | | | | | | | | |
Collapse
|
2
|
İkiz Bozsoy M, Parlak Kocabay A, Koska B, Demirtaş Yılmaz B, Özses M, Avcı NB, Akkaplan S, Budak Ateş Z, Çınar BÇ, Yaralı M, Özbal Batuk M, Sennaroğlu G, Sennaroğlu L. Intraoperative impedance and ECAP results in cochlear implant recipients with inner ear malformations and normal cochlear anatomy: a retrospective analysis. Acta Otolaryngol 2025:1-7. [PMID: 39835594 DOI: 10.1080/00016489.2025.2452346] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/14/2024] [Revised: 01/03/2025] [Accepted: 01/07/2025] [Indexed: 01/22/2025]
Abstract
BACKGROUND The intraoperative measurements are essential steps in cochlear implant (CI) surgery for confirming correct electrode placement. OBJECTIVES To examine the intraoperative impedance and electrically evoked action potential (ECAP) measurement results of cochlear implant (CI) users with normal cochlear anatomy (NCA) and to compare them with CI users with inner ear malformations (IEM). MATERIAL AND METHODS This retrospective study included intraoperative data of 300 ears from 258 individuals using Medel® and Cochlear (Nucleus®) CI devices. RESULTS Impedance values differed through all regions, and that differences in ECAPs results mainly stemmed from the basal region in Cochlear users, when comparing the impedance values and ECAPs recording prevalence between the NCA and IEM groups, it was observed that there was no significant difference in the impedance values across the intracochlear regions of the groups (apical; p = .26, middle; p = .12, basal; p = .99). However, it was found that the prevalence of measurable ECAPs in all intracochlear regions of the NCA group was higher than the IEM group (p = .000). CONCLUSION AND SIGNIFICANCE The robustness of cochlear structures is a crucial factor in the recording of ECAPs. Furthermore, findings in the IEM group demonstrated that proper placement of intracochlear electrodes did not guarantee effective auditory nerve stimulation.
Collapse
Affiliation(s)
- Merve İkiz Bozsoy
- Department of Speech and Language Therapy, Anadolu University, Eskisehir, Turkey
| | | | - Betül Koska
- Department of Audiology, Hacettepe University, Ankara, Turkey
- Department of Audiology, Adnan Menderes University, Aydın, Turkey
| | | | - Merve Özses
- Department of Audiology, Adnan Menderes University, Aydın, Turkey
| | | | - Selvet Akkaplan
- Department of Audiology, Hacettepe University, Ankara, Turkey
| | - Zeynep Budak Ateş
- Department of Audiology, Hacettepe University, Ankara, Turkey
- Department of Audiology, Inonu University, Malatya, Turkey
| | | | - Mehmet Yaralı
- Department of Audiology, Hacettepe University, Ankara, Turkey
| | | | | | - Levent Sennaroğlu
- Department of Otolaryngology, Hacettepe University School of Medicine, Ankara, Turkey
| |
Collapse
|
3
|
Mewes A, Dambon J, Brademann G, Hey M. Curvature analysis of CI electrode arrays: a novel approach to categorize perimodiolar positions without anatomical landmarks. Eur Arch Otorhinolaryngol 2025; 282:145-154. [PMID: 39214908 PMCID: PMC11735585 DOI: 10.1007/s00405-024-08917-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/24/2024] [Accepted: 08/12/2024] [Indexed: 09/04/2024]
Abstract
PURPOSE Perimodiolar electrode arrays may be positioned regular, over-inserted or under-inserted into the cochlea depending on the cochlear size and shape. The study aimed to examine whether there are differences between these groups in the local curvature along the intracochlear array. Individual curvature variables were developed to categorize the groups and the relationship between the curvature and the angular insertion depth at the electrode tip was analyzed. METHODS The curvature along the intracochlear array was measured in the CBCT image of 85 perimodiolar electrodes of a single type. The mean curvature and the ratio of the mean curvature at contacts E14-16 to the mean curvature at E7-8 (bowing ratio) were calculated across the array, and its true positive rate (TPR) and false positive rate (FPR) were calculated to establish optimal threshold values to categorize the groups. RESULTS 68.2% of the cases were categorized as regular positioned, 22.4% had an over-insertion and 9.4% had an under-insertion. The mean curvature was significantly weaker with under-insertion (< 342°) than with normal insertion depth (≥ 342°). With an over-insertion, the bowing ratio was < 1 and otherwise > 1. Both the mean curvature and bowing ratio were found to have an optimal threshold value with high TPR (= 1.00) and low FPR (≤ 0.06) for categorizing under-insertion and over-insertion, respectively. CONCLUSION Curvature analysis is a useful tool to assess if a perimodiolar electrode array has been inserted deep enough into the cochlea. Independent of critical anatomical landmarks, over-inserted arrays and under-inserted arrays could be well categorized by using individual curvature variables. The results need to be validated using additional data sets.
Collapse
Affiliation(s)
- Alexander Mewes
- Christian-Albrecht University of Kiel, Kiel, Germany.
- Department of Otorhinolaryngology, Head and Neck Surgery, Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Kiel, Germany.
| | - Jan Dambon
- Department of Otorhinolaryngology, Head and Neck Surgery, Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Kiel, Germany
| | - Goetz Brademann
- Department of Otorhinolaryngology, Head and Neck Surgery, Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Kiel, Germany
| | - Matthias Hey
- Department of Otorhinolaryngology, Head and Neck Surgery, Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Kiel, Germany
| |
Collapse
|
4
|
Tejani V, Piper R, Murray G, Manzoor NF, Mowry S, Semaan M, Rivas A. Sensitivity and Costs of Intraoperative Trans-Impedance Matrix Recordings, Spread of Excitation Functions, and X-ray Imaging in Detecting Cochlear Implant Tip Foldovers. Otol Neurotol 2024; 45:e763-e771. [PMID: 39514433 DOI: 10.1097/mao.0000000000004361] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/16/2024]
Abstract
OBJECTIVE Evaluate the sensitivity and financial costs of Trans-Impedance Matrix recordings, Spread of Excitation functions, and x-rays in detecting cochlear implant tip foldovers. SETTING Tertiary academic medical center. PATIENTS 113 ears of 108 patients. INTERVENTIONS Following cochlear implantation and before concluding surgery, intraoperative Trans-Impedance Matrix recordings, Spread of Excitation functions, and x-rays were conducted to evaluate presence of tip foldover. MAIN OUTCOME MEASURES Presence of tip foldover; recording time necessary for and costs of Trans-Impedance Matrix, spread of excitation, and x-rays. RESULTS There were six tip foldovers. Trans-Impedance Matrix showed 100% sensitivity, 100% specificity, 100% positive predictive value, and 100% negative predicative value in detecting tip foldovers. Spread of excitation showed 29% sensitivity, 99% specificity, 67% positive predictive value, and 95% negative predicative value. Trans-Impedance Matrix recordings were completed significantly faster than spread of excitation and x-rays. Elimination of x-rays from our intraoperative workflow results in a twofold cost reduction. CONCLUSION Trans-Impedance Matrix recordings have potential great clinical utility in evaluating proper CI placement intraoperatively and reducing costs of surgery while not compromising patient care. Given the low tip foldover rate, a multicenter study is in progress to evaluate the sensitivity, specificity, positive predictive value, and negative predicative value of Trans-Impedance Matrix in a larger dataset. This can provide better guidance to cochlear implant clinics interested in evaluating the impact of using Trans-Impedance Matrix on patient care as well as the economics of reducing use of intraoperative imaging.
Collapse
Affiliation(s)
| | | | | | - Nauman F Manzoor
- Department of Otolaryngology-Head and Neck Surgery, Virginia Commonwealth University, Richmond, Virginia
| | | | | | | |
Collapse
|
5
|
Panah N, Brazin A, Ebrahimi Shahmabadi H. Electrophysiological Characteristics in Pediatric Cochlear Implantation. Indian J Otolaryngol Head Neck Surg 2024; 76:4962-4973. [PMID: 39376381 PMCID: PMC11456142 DOI: 10.1007/s12070-024-04806-5] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2024] [Accepted: 06/07/2024] [Indexed: 10/09/2024] Open
Abstract
AIMS Cochlear implantation is a potential intervention for individuals with severe to profound hearing loss, in particular in the pediatric population. This literature review aims to comprehensively evaluate the applications of electrophysiological tests in enhancing cochlear implant (CI) outcomes for children. METHODS A literature review searched Medline and PubMed databases for articles on electrophysiological tests in CI children, using the terms "electrophysiological tests," "children," and "cochlear implant." The systematic search leads to 72 eligible texts. RESULTS Electrophysiological tests can be used to test CI children without the need for their active participation. These tests can be helpful in identifying and improving the health of deaf children in various ways, such as determining the CI functional status, the semantic integration effects in CI children, the effect of central auditory structures in speech stimulus processing, the development of lexical-semantic in CI children, and tracking the maturation of the central auditory system. CI enhances central auditory nervous system (CANS) maturation and auditory/language skills. CONCLUSION The quality of electrophysiological tests can be improved to enhance hearing outcome prediction, postoperative physiology understanding, and hearing loss mechanisms. Electrophysiological tests study CANS maturation, identify lesions, aid CI programming, determine prognosis, and treatment outcomes.
Collapse
Affiliation(s)
- Naomi Panah
- School of Health and Rehabilitation Sciences, The University of Queensland, Brisbane, Australia
| | - Ali Brazin
- Department of Otolaryngology, Faculty of Medicine, Rafsanjan University of Medical Sciences, Rafsanjan, Iran
- Clinical Research Development Unit (CRDU), Moradi Hospital, Rafsanjan University of Medical Sciences, Rafsanjan, Iran
| | - Hasan Ebrahimi Shahmabadi
- Immunology of Infectious Diseases Research Center, Research Institute of Basic Medical Sciences, Rafsanjan University of Medical Sciences, Rafsanjan, Iran
| |
Collapse
|
6
|
Chai B, Holland ML, Camposeo EL, King K, Schvartz-Leyzac KC. Patient and Device Factors Contributing to Electrically Evoked Stapedial Reflex Thresholds in Cochlear Implanted Adults. Audiol Neurootol 2024; 29:263-270. [PMID: 38342083 PMCID: PMC11305975 DOI: 10.1159/000535058] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2023] [Accepted: 10/22/2023] [Indexed: 02/13/2024] Open
Abstract
INTRODUCTION Optimal cochlear implant (CI) outcomes are due to, at least in part, appropriate device programming. Objective measures, such as electrically evoked stapedial reflex thresholds (ESRTs), can be used to more accurately set programming levels. However, underlying factors that contribute to ESRT levels are not well understood. The objective of the current study was to analyze how demographic variables of patient sex and age, along with CI electrode location, influence ESRTs in adult CI recipients. METHODS A single institution retrospective review was performed. Electronic medical records, CI programming records, and clinic database of postoperative computerized tomography were reviewed to gather information regarding patient demographics, ESRTs, and electrode array metrics including medial-lateral distance and scalar location. Linear mixed models were constructed to determine how demographic variables and electrode position influence ESRTs recorded in 138 adult CI recipients. RESULTS ESRTs were significantly affected by recipient age, with older listeners demonstrating higher ESRT levels. On average, males had higher ESRT levels when compared to females. In a subset of the study sample, ESRT levels increased with increasing medial-lateral distance; however, there was not a statistically significant effect of electrode type (lateral/straight arrays compared to perimodiolar arrays). ESRTs were not affected by scalar location. DISCUSSION/CONCLUSIONS The results suggest that key demographic and electrode position characteristics influence the level of ESRTs in adult CI recipients. While ESRTs are widely used to assist with CI programming, underlying factors are not well understood. The significant factors of aging and sex could be due to middle ear mechanics or neural health differences. However, further data are needed to better understand these associations.
Collapse
Affiliation(s)
- Brianna Chai
- Department of Otolaryngology- Head and Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Mary Laing Holland
- Department of Otolaryngology- Head and Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Elizabeth L Camposeo
- Department of Otolaryngology- Head and Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Kaylene King
- Department of Otolaryngology- Head and Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| | - Kara C Schvartz-Leyzac
- Department of Otolaryngology- Head and Neck Surgery, Medical University of South Carolina, Charleston, South Carolina, USA
| |
Collapse
|
7
|
Aljazeeri IA, Hagr A. Application of anatomy-based spacing of electrode contacts for achieving a uniform semitonal resolution: A novel concept in cochlear implant electrode design. Sci Rep 2024; 14:2645. [PMID: 38302541 PMCID: PMC10834526 DOI: 10.1038/s41598-024-53070-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/19/2023] [Accepted: 01/27/2024] [Indexed: 02/03/2024] Open
Abstract
Using anatomy-based fitting, we can determine the place-specific map with individualized center frequencies for each electrode contact that is a closer match to the natural pitch-place of the cochlea. The primary objective of this study is to evaluate the tonal presentation across the electrode array and to calculate the semitone difference between each adjacent pair of contacts according to their anatomy-based map. The secondary objective is to determine the distancing of the contacts that would result in an equal semitone difference with a uniform tonal presentation. A total of 167 ears were included in this retrospective study. The frequencies across the electrode arrays were found to be unequally presented. The semitonal condensations were higher in the apical inter-contact spaces compared to the basal inter-contact spaces, being 3.0-2.3 semitones/mm (Kruskal Wallis test, p < 0.000). The anatomy-based spacing of the electrode contacts was larger in the basal inter-contact spaces compared to the apical inter-contact spaces, ranging from 1.92 to 1.48 mm. In conclusion, the current electrode designs do not have uniform tonal representation throughout the electrode array. There is a more condensed tonal presentation in the apical electrodes than in the basal electrodes, resulting in a lower tonal resolution in the apical region.
Collapse
Affiliation(s)
- Isra Ali Aljazeeri
- King Abdullah Ear Specialist Center (KAESC), College of Medicine, King Saud University Medical City (KSUMC), King Saud University, PO Box 245, 11411, Riyadh, Saudi Arabia.
- Otolaryngology and Ophthalmology Specialized Aljaber Hospital, Ministry of Health, Ahsa, Saudi Arabia.
| | - Abdulrahman Hagr
- King Abdullah Ear Specialist Center (KAESC), College of Medicine, King Saud University Medical City (KSUMC), King Saud University, PO Box 245, 11411, Riyadh, Saudi Arabia
| |
Collapse
|
8
|
Hasan Z, Key S, Lee M, Da Cruz M. Systematic Review of Intracochlear Measurements and Effect on Postoperative Auditory Outcomes after Cochlear Implant Surgery. Otol Neurotol 2024; 45:e1-e17. [PMID: 38013462 DOI: 10.1097/mao.0000000000004044] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2023]
Abstract
OBJECTIVE Quality and adequacy of the electrode neuron interface (ENI) is postulated to be a determining factor in affecting auditory outcomes after cochlear implantation. This study aims to review radiological parameters affecting ENI, including angular insertion (AngI), wrapping factor (WF), scalar translocation (ScaT), and electrode-modiolar distance (EMD) and their effect on auditory outcomes. DATABASES REVIEWED PubMed, MEDLINE, Embase, Scopus, OpenGrey, and Google Scholar from inception to 01 September 2022. METHODS Inclusion criteria were (i) all humans with any cochlear implant (CI); (ii) postoperative cross-sectional imaging with electrode position factors of AngI, ScaT, EMD, and/or WF; and (iii) associated auditory outcomes. Search was restricted to English-language literature. Two independent reviewers performed title and abstract screening, data extraction, and ROBINS-I risk of bias assessment. Formal statistical analysis not performed due to data heterogeneity. PROSPERO (CRD42022359198). RESULTS Thirty-one studies (n = 2,887 patients, 3,091 electrodes) underwent qualitative synthesis. Higher AngI (n = 1921 patients) demonstrated positive correlation in 11 studies, no correlation in eight studies, and negative correlation in four studies. ScaT (n = 2,115 patients) demonstrated negative correlation in 12 studies, none in six studies, and one unclear correlation. Larger EMD (n = 240 patients) showed negative correlation in two studies, no correlation in one, and unclear correlation in one study. Smaller WF (n = 369 patients) demonstrated no correlation in three studies and positive correlation in one study. CONCLUSIONS Our study finds variable reported relationship between AngI and auditory outcomes. CI electrodes with a ScaT or larger EMD are more likely to exhibit poorer outcomes, and WF does not correlate with outcomes.
Collapse
Affiliation(s)
| | - Seraphina Key
- Faculty of Medicine and Health, University of Sydney, Australia
| | - Michael Lee
- Department of Otolaryngology Head and Neck Surgery, Westmead Hospital, Sydney, Australia
| | | |
Collapse
|
9
|
Franke-Trieger A, Lailach S, Shetty J, Murrmann K, Zahnert T, Neudert M. Word Recognition with a Cochlear Implant in Relation to Prediction and Electrode Position. J Clin Med 2023; 13:183. [PMID: 38202190 PMCID: PMC10780042 DOI: 10.3390/jcm13010183] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/20/2023] [Revised: 12/11/2023] [Accepted: 12/21/2023] [Indexed: 01/12/2024] Open
Abstract
BACKGROUND the word recognition score (WRS) achieved with cochlear implants (CIs) varies widely. To account for this, a predictive model was developed based on patients' age and their pre-operative WRS. This retrospective study aimed to find out whether the insertion depth of the nucleus lateral-wall electrode arrays contributes to the deviation of the CI-achieved WRS from the predicted WRS. MATERIALS AND METHODS patients with a pre-operative maximum WRS > 0 or a pure-tone audiogram ≥80 dB were included. The insertion depth was determined via digital volume tomography. RESULTS fifty-three patients met the inclusion criteria. The median WRS achieved with the CI was 70%. The comparison of pre- and post-operative scores achieved with a hearing aid and a CI respectively in the aided condition showed a median improvement of 65 percentage points (pp). A total of 90% of the patients improved by at least 20 pp. The majority of patients reached or exceeded the prediction, with a median absolute error of 11 pp. No significant correlation was found between the deviation from the predicted WRS and the insertion depth. CONCLUSIONS our data support a previously published model for the prediction of the WRS after cochlear implantation. For the lateral-wall electrode arrays evaluated, the insertion depth did not influence the WRS with a CI.
Collapse
Affiliation(s)
- Annett Franke-Trieger
- Department of Otorhinolaryngology, Head and Neck Surgery, Faculty of Medicine Carl Gustav Carus, Technische Universität Dresden, Fetscherstraße 74, 01307 Dresden, Germany (T.Z.)
| | | | | | | | | | | |
Collapse
|
10
|
Liebscher T, Hornung J, Hoppe U. Electrically evoked compound action potentials in cochlear implant users with preoperative residual hearing. Front Hum Neurosci 2023; 17:1125747. [PMID: 37850038 PMCID: PMC10577430 DOI: 10.3389/fnhum.2023.1125747] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/16/2022] [Accepted: 09/08/2023] [Indexed: 10/19/2023] Open
Abstract
Introduction Residual hearing in cochlear implant (CI) candidates requires the functional integrity of the nerve in particular regions of the cochlea. Nerve activity can be elicited as electrically evoked compound action potentials (ECAP) after cochlear implantation. We hypothesize that ECAP thresholds depend on preoperative residual hearing ability. Materials and methods In a retrospective study, we analyzed 84 adult cochlear implant users who had received a Nucleus® CI632 Slim Modiolar Electrode and who preoperatively had had residual hearing. Inclusion criteria were severe to profound hearing loss with preoperative measurable hearing in the ear to receive the implant, postlingual hearing loss, German as native language and correct placement of the electrode, inserted completely into the scala tympani. Electrically evoked compound action potential (ECAP) was recorded intraoperatively. The angular insertion was measured for each electrode contact from postoperative computed tomography to estimate the corresponding spiral ganglion frequency. Pure-tone audiometry and allocated ECAP thresholds were tested to investigate possible correlation. Results The average of hearing thresholds, tested at 0.5, 1, 2, and 4 kHz (4FPTA) was 82 ± 18 (range 47-129) dB HL. The success rate for recording ECAP thresholds was 96.9%. For all comparable pure-tone frequencies (1, 2, 4, and 8 kHz), there was significant correlation between preoperative hearing levels and intraoperative ECAP thresholds (p < 0.001). Higher hearing thresholds are associated with increased ECAP thresholds. Conclusion In CI candidates with adequate residual hearing, intraoperative electrophysiological measurement records lower thresholds. This outcome may be explained by the neural survival density of the peripheral system, with less neural degeneration.
Collapse
Affiliation(s)
- Tim Liebscher
- ENT-Clinic, Department of Audiology, Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | | | | |
Collapse
|
11
|
Mewes A, Bennett C, Dambon J, Brademann G, Hey M. Evaluation of CI electrode position from imaging: comparison of an automated technique with the established manual method. BMC Med Imaging 2023; 23:143. [PMID: 37773060 PMCID: PMC10543862 DOI: 10.1186/s12880-023-01102-6] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/13/2023] [Accepted: 09/13/2023] [Indexed: 09/30/2023] Open
Abstract
BACKGROUND A manual evaluation of the CI electrode position from CT and DVT scans may be affected by diagnostic errors due to cognitive biases. The aim of this study was to compare the CI electrode localization using an automated method (image-guided cochlear implant programming, IGCIP) with the clinically established manual method. METHODS This prospective experimental study was conducted on a dataset comprising N=50 subjects undergoing cochlear implantation with a Nucleus® CI532 or CI632 Slim Modiolar electrode. Scalar localization, electrode-to-modiolar axis distances (EMD) and angular insertion depth (aDOI) were compared between the automated IGCIP tool and the manual method. Two raters made the manual measurements, and the interrater reliability (±1.96·SD) was determined as the reference for the method comparison. The method comparison was performed using a correlation analysis and a Bland-Altman analysis. RESULTS Concerning the scalar localization, all electrodes were localized both manually and automatically in the scala tympani. The interrater differences ranged between ±0.2 mm (EMD) and ±10° (aDOI). There was a bias between the automatic and manual method in measuring both localization parameters, which on the one hand was smaller than the interrater variations. On the other hand, this bias depended on the magnitude of the EMD respectively aDOI. A post-hoc analysis revealed that the deviations between the methods were likely due to a different selection of mid-modiolar axis. CONCLUSIONS The IGCIP is a promising tool for automated processing of CT and DVT scans and has useful functionality such as being able to segment the cochlear using post-operative scans. When measuring EMD, the IGCIP tool is superior to the manual method because the smallest possible distance to the axis is determined depending on the cochlear turn, whereas the manual method selects the helicotrema as the reference point rigidly. Functionality to deal with motion artifacts and measurements of aDOI according to the consensus approach are necessary, otherwise the IGCIP is not unrestrictedly ready for clinical use.
Collapse
Affiliation(s)
- Alexander Mewes
- Department of Otorhinolaryngology, Head and Neck Surgery, Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Arnold-Heller-Straße 3, 24105, Kiel, Germany.
| | | | - Jan Dambon
- Department of Otorhinolaryngology, Head and Neck Surgery, Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Arnold-Heller-Straße 3, 24105, Kiel, Germany
| | - Goetz Brademann
- Department of Otorhinolaryngology, Head and Neck Surgery, Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Arnold-Heller-Straße 3, 24105, Kiel, Germany
| | - Matthias Hey
- Department of Otorhinolaryngology, Head and Neck Surgery, Universitätsklinikum Schleswig-Holstein (UKSH), Campus Kiel, Arnold-Heller-Straße 3, 24105, Kiel, Germany
| |
Collapse
|
12
|
Panario J, Bester C, O'Leary SJ. Characteristics of the Summating Potential Measured Across a Cochlear Implant Array as an Indicator of Cochlear Function. Ear Hear 2023; 44:1088-1106. [PMID: 36935398 PMCID: PMC10426787 DOI: 10.1097/aud.0000000000001347] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/13/2022] [Accepted: 01/13/2023] [Indexed: 03/21/2023]
Abstract
OBJECTIVES The underlying state of cochlear and neural tissue function is known to affect postoperative speech perception following cochlear implantation. The ability to assess these tissues in patients can be performed using intracochlear electrocochleography (IC ECochG). One component of ECochG is the summating potential (SP) that appears to be generated by multiple cochlear tissues. Its qualities may be able to detect the presence of functional inner hair cells, but evidence for this is limited in human cochleae. This study aimed to examine the IC SP characteristics in cochlear implantation recipients, its relationship to preoperative speech perception and audiometric thresholds, and to other IC ECochG components. DESIGN This is a retrospective analysis of 113 patients' IC ECochG recordings across the array in response to a 500 Hz tone burst stimulus. Responses to condensation and rarefaction stimuli were then subtracted from one another to emphasize the cochlear microphonic and added to one another to emphasize the SP, auditory nerve neurophonic, and compound action potential. Patients were grouped based on their maximum SP deflection being large and positive (+SP), large and negative (-SP), or minimal (0 SP) to further investigate these relationships. RESULTS Patients in the +SP group had better preoperative speech perception (mean consonant-vowel-consonant phoneme score 46%) compared to the -SP and 0 SP groups (consonant-vowel-consonant phoneme scores 34% and 36%, respectively, difference to +SP: p < 0.05). Audiometric thresholds were lowest for +SP (mean pure-tone average 50 dB HL), then -SP (65 dB HL), and highest for 0 SP patients (70 dB HL), but there was not a statistical significance between +SP and -SP groups ( p > 0.1). There were also distinct differences between SP groups in the qualities of their other ECochG components. These included the +SP patients having larger cochlear microphonic maximum amplitude, more apical SP peak electrode locations, and a more spatially specific SP magnitude growth pattern across the array. CONCLUSIONS Patients with large positive SP deflection in IC ECochG have preoperatively better speech perception and lower audiometric thresholds than those without. Patterns in other ECochG components suggest its positive deflection may be an indicator of cochlear function.
Collapse
Affiliation(s)
- Jared Panario
- Department Otolaryngology, University of Melbourne, Victoria, Australia
| | - Christofer Bester
- Department Otolaryngology, University of Melbourne, Victoria, Australia
| | - Stephen John O'Leary
- Department Otolaryngology, University of Melbourne, Victoria, Australia
- Royal Victorian Eye and Ear Hospital, Victoria, Australia
| |
Collapse
|
13
|
Starovoyt A, Quirk BC, Putzeys T, Kerckhofs G, Nuyts J, Wouters J, McLaughlin RA, Verhaert N. An optically-guided cochlear implant sheath for real-time monitoring of electrode insertion into the human cochlea. Sci Rep 2022; 12:19234. [PMID: 36357503 PMCID: PMC9649659 DOI: 10.1038/s41598-022-23653-4] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/01/2022] [Accepted: 11/03/2022] [Indexed: 11/12/2022] Open
Abstract
In cochlear implant surgery, insertion of perimodiolar electrode arrays into the scala tympani can be complicated by trauma or even accidental translocation of the electrode array within the cochlea. In patients with partial hearing loss, cochlear trauma can not only negatively affect implant performance, but also reduce residual hearing function. These events have been related to suboptimal positioning of the cochlear implant electrode array with respect to critical cochlear walls of the scala tympani (modiolar wall, osseous spiral lamina and basilar membrane). Currently, the position of the electrode array in relation to these walls cannot be assessed during the insertion and the surgeon depends on tactile feedback, which is unreliable and often comes too late. This study presents an image-guided cochlear implant device with an integrated, fiber-optic imaging probe that provides real-time feedback using optical coherence tomography during insertion into the human cochlea. This novel device enables the surgeon to accurately detect and identify the cochlear walls ahead and to adjust the insertion trajectory, avoiding collision and trauma. The functionality of this prototype has been demonstrated in a series of insertion experiments, conducted by experienced cochlear implant surgeons on fresh-frozen human cadaveric cochleae.
Collapse
Affiliation(s)
- Anastasiya Starovoyt
- grid.5596.f0000 0001 0668 7884Department of Neurosciences, ExpORL, KU Leuven, 3000 Leuven, Belgium ,grid.5596.f0000 0001 0668 7884Department of Neurosciences, Leuven Brain Institute, KU Leuven, 3000 Leuven, Belgium
| | - Bryden C. Quirk
- grid.1010.00000 0004 1936 7304Australian Research Council Centre of Excellence for Nanoscale BioPhotonics, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA 5005 Australia ,grid.1010.00000 0004 1936 7304Institute for Photonics and Advanced Sensing, The University of Adelaide, Adelaide, SA 5005 Australia
| | - Tristan Putzeys
- grid.5596.f0000 0001 0668 7884Department of Neurosciences, ExpORL, KU Leuven, 3000 Leuven, Belgium ,grid.5596.f0000 0001 0668 7884Department of Neurosciences, Leuven Brain Institute, KU Leuven, 3000 Leuven, Belgium ,grid.5596.f0000 0001 0668 7884Laboratory for Soft Matter and Biophysics, Department of Physics and Astronomy, KU Leuven, 3000 Leuven, Belgium
| | - Greet Kerckhofs
- grid.7942.80000 0001 2294 713XBiomechanics Laboratory, Institute of Mechanics, Materials, and Civil Engineering, UCLouvain, 1348 Louvain-La-Neuve, Belgium ,grid.5596.f0000 0001 0668 7884Department of Materials Science and Engineering, KU Leuven, 3000 Leuven, Belgium ,grid.7942.80000 0001 2294 713XInstitute of Experimental and Clinical Research, UCLouvain, 1200 Woluwé-Saint-Lambert, Belgium ,grid.5596.f0000 0001 0668 7884Prometheus, Division of Skeletal Tissue Engineering, KU Leuven, 3000 Leuven, Belgium
| | - Johan Nuyts
- grid.5596.f0000 0001 0668 7884Department of Imaging and Pathology, Division of Nuclear Medicine, KU Leuven, 3000 Leuven, Belgium ,Nuclear Medicine and Molecular Imaging, Medical Imaging Research Center, 3000 Leuven, Belgium
| | - Jan Wouters
- grid.5596.f0000 0001 0668 7884Department of Neurosciences, ExpORL, KU Leuven, 3000 Leuven, Belgium ,grid.5596.f0000 0001 0668 7884Department of Neurosciences, Leuven Brain Institute, KU Leuven, 3000 Leuven, Belgium
| | - Robert A. McLaughlin
- grid.1010.00000 0004 1936 7304Australian Research Council Centre of Excellence for Nanoscale BioPhotonics, Faculty of Health and Medical Sciences, The University of Adelaide, Adelaide, SA 5005 Australia ,grid.1010.00000 0004 1936 7304Institute for Photonics and Advanced Sensing, The University of Adelaide, Adelaide, SA 5005 Australia ,grid.1012.20000 0004 1936 7910School of Engineering, University of Western Australia, Perth, WA 6009 Australia
| | - Nicolas Verhaert
- grid.5596.f0000 0001 0668 7884Department of Neurosciences, ExpORL, KU Leuven, 3000 Leuven, Belgium ,grid.5596.f0000 0001 0668 7884Department of Neurosciences, Leuven Brain Institute, KU Leuven, 3000 Leuven, Belgium ,grid.410569.f0000 0004 0626 3338Department of Otorhinolaryngology, Head and Neck Surgery, University Hospitals of Leuven, 3000 Leuven, Belgium
| |
Collapse
|
14
|
Munhall CC, Noble JH, Dawant B, Labadie RF. Cochlear Implant Translocation: Diagnosis, Prevention, and Clinical Implications. CURRENT OTORHINOLARYNGOLOGY REPORTS 2022. [DOI: 10.1007/s40136-022-00434-1] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
15
|
Sahai I, Ghosh B, Anjankar A. A Spectrum of Intraoperative and Postoperative Complications of Cochlear Implants: A Critical Review. Cureus 2022; 14:e28151. [PMID: 36148185 PMCID: PMC9482671 DOI: 10.7759/cureus.28151] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/12/2022] [Accepted: 08/18/2022] [Indexed: 11/05/2022] Open
Abstract
A cochlear implant is a neuroprosthetic, electrical device that is developed for the treatment of patients who have sensory hearing loss. It directly stimulates the hearing nerve by bypassing the injured or damaged sensory receptors, the hair cells. This implant is directly placed in the inner ear. It is an electronic device which is proved to be very useful in patients with sensorineural hearing loss. This implant consists of a speech processor (externally present), which takes up the sound; transforms it into digital signals, and then internal components take it to convert it into electrical energy, which stimulates auditory nerves, and the brain perceives it and hears it as a sound. This is one of the most successful surgeries, which happens very frequently nowadays. Although, many complications are mostly associated with this implant. This paper deals with the preoperative, operative, and postoperative complications associated with cochlear implant surgery. That includes tinnitus, Meniere's disease, unilateral hearing loss, musical ear syndrome, infections; flap necrosis, facial nerve palsy, improper electrode placement, magnet displacement; failure and re-implantation, cholesteatoma, and pneumocephalus. These are just a few of the complications; there are much more complications which are associated with cochlear implants.
Collapse
Affiliation(s)
- Isha Sahai
- Otolaryngology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Medical Sciences, Wardha, IND
| | - Benumadhab Ghosh
- Otolaryngology, Jawaharlal Nehru Medical College, Datta Meghe Institute of Medical Sciences, Wardha, IND
| | - Ashish Anjankar
- Biochemistry, Jawaharlal Nehru Medical College, Datta Meghe Institute of Medical Sciences, Wardha, IND
| |
Collapse
|
16
|
High-speed flat-detector computed tomography for temporal bone imaging and postoperative control of cochlear implants. Neuroradiology 2022; 64:1437-1445. [PMID: 35410396 PMCID: PMC9177478 DOI: 10.1007/s00234-022-02940-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/19/2021] [Accepted: 04/03/2022] [Indexed: 10/30/2022]
Abstract
PURPOSE Flat-detector computed tomography (FD-CT) is the standard for cochlear implant (CI) imaging. FD-CT systems differ in technical characteristics. Our aim was an evaluation of two different FD-CT generations with different protocols and hardware regarding image quality, radiation dose, and scan time. METHODS Two temporal bone specimens (- / + CI = TB0/TB1) were scanned using three different scanners: two FD-CT systems with different scanning protocols (standard FD-CT: 20 s 70 kV, 20 s 109 kV; high-speed FD-CT [HS-FD-CT]: 7 s 109 kV, 9 s 109 kV, 14 s 72 kV) and MS-CT (5 s 120 kV). Acquired datasets were evaluated in consensus reading regarding qualitative and quantitative parameters: addressing CI- and cochlea-specific parameters, cochlea delineation, lamina spiralis ossea visibility, distinction of single CI electrodes, determination of intracochlear implant position, stapes delineation, and mastoidal septation were assessed. Addressing protocol-specific parameters, radiation dose (dose-length-product/DLP), and scan time were assessed. RESULTS Two HS-FD-CT protocols (14 s/9 s) provide higher or equivalent diagnostic information regarding CI- and cochlea-specific parameters compared to both standard FD-CT protocols. The fastest HS-FD-CT protocol (7 s)-providing inferior diagnostic information compared to all other FD-CT protocols-still exceeds MS-CT. The highest DLP was recorded for the 14 s HS-FD-CT protocol (TB1 = 956 mGycm); the lowest DLPs were recorded for the 7 s HS-FD-CT protocol (TB0 = 188 mGycm) and for MS-CT (TB0 = 138 mGycm), respectively. HS-FD-CT allows a significant reduction of scan time compared to standard FD-CT. CONCLUSION High-speed FD-CT improves visualization of temporal bone anatomy and postoperative assessment of CIs by combining excellent image quality, fast scan time, and reasonable radiation exposure.
Collapse
|
17
|
Van de Heyning P, Roland P, Lassaletta L, Agrawal S, Atlas M, Baumgartner WD, Brown K, Caversaccio M, Dazert S, Gstoettner W, Hagen R, Hagr A, Jablonski GE, Kameswaran M, Kuzovkov V, Leinung M, Li Y, Loth A, Magele A, Mlynski R, Mueller J, Parnes L, Radeloff A, Raine C, Rajan G, Schmutzhard J, Skarzynski H, Skarzynski PH, Sprinzl G, Staecker H, Stöver T, Tavora-Viera D, Topsakal V, Usami SI, Van Rompaey V, Weiss NM, Wimmer W, Zernotti M, Gavilan J. Suitable Electrode Choice for Robotic-Assisted Cochlear Implant Surgery: A Systematic Literature Review of Manual Electrode Insertion Adverse Events. Front Surg 2022; 9:823219. [PMID: 35402479 PMCID: PMC8987358 DOI: 10.3389/fsurg.2022.823219] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2021] [Accepted: 02/09/2022] [Indexed: 12/05/2022] Open
Abstract
Background and Objective The cochlear implant (CI) electrode insertion process is a key step in CI surgery. One of the aims of advances in robotic-assisted CI surgery (RACIS) is to realize better cochlear structure preservation and to precisely control insertion. The aim of this literature review is to gain insight into electrode selection for RACIS by acquiring a thorough knowledge of electrode insertion and related complications from classic CI surgery involving a manual electrode insertion process. Methods A systematic electronic search of the literature was carried out using PubMed, Scopus, Cochrane, and Web of Science to find relevant literature on electrode tip fold over (ETFO), electrode scalar deviation (ESD), and electrode migration (EM) from both pre-shaped and straight electrode types. Results A total of 82 studies that include 8,603 ears implanted with a CI, i.e., pre-shaped (4,869) and straight electrodes (3,734), were evaluated. The rate of ETFO (25 studies, 2,335 ears), ESD (39 studies, 3,073 ears), and EM (18 studies, 3,195 ears) was determined. An incidence rate (±95% CI) of 5.38% (4.4-6.6%) of ETFO, 28.6% (26.6-30.6%) of ESD, and 0.53% (0.2-1.1%) of EM is associated with pre-shaped electrodes, whereas with straight electrodes it was 0.51% (0.1-1.3%), 11% (9.2-13.0%), and 3.2% (2.5-3.95%), respectively. The differences between the pre-shaped and straight electrode types are highly significant (p < 0.001). Laboratory experiments show evidence that robotic insertions of electrodes are less traumatic than manual insertions. The influence of round window (RW) vs. cochleostomy (Coch) was not assessed. Conclusion Considering the current electrode designs available and the reported incidence of insertion complications, the use of straight electrodes in RACIS and conventional CI surgery (and manual insertion) appears to be less traumatic to intracochlear structures compared with pre-shaped electrodes. However, EM of straight electrodes should be anticipated. RACIS has the potential to reduce these complications.
Collapse
Affiliation(s)
- Paul Van de Heyning
- Department of Otorhinolaryngology Head and Neck Surgery, Antwerp University Hospital, University of Antwerp, Antwerp, Belgium
- Department of Translational Neurosciences, University of Antwerp, Antwerp, Belgium
| | - Peter Roland
- Department of Otolaryngology, Head & Neck Surgery, University of Texas Southwestern Medical Center, Dallas, TX, United States
| | - Luis Lassaletta
- Hospital Universitario La Paz, Institute for Health Research (IdiPAZ), Madrid, Spain
| | - Sumit Agrawal
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, ON, Canada
| | - Marcus Atlas
- Ear Sciences Institute Australia, Lions Hearing Clinic, Perth, WA, Australia
| | | | - Kevin Brown
- UNC Ear and Hearing Center at Chapel Hill School of Medicine, Chapel Hill, NC, United States
| | - Marco Caversaccio
- Department for ENT, Head and Neck Surgery, Bern University Hospital, Bern, Switzerland
| | - Stefan Dazert
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth University Hospital Bochum, Bochum, Germany
| | | | - Rudolf Hagen
- Würzburg ENT University Hospital, Würzburg, Germany
| | - Abdulrahman Hagr
- King Abdullah Ear Specialist Center, King Saud University Medical City, King Saud University, Riyadh, Saudi Arabia
| | - Greg Eigner Jablonski
- Institute of Clinical Medicine, University of Oslo, Oslo, Norway
- Department of Otorhinolaryngology & Head and Neck Surgery, Oslo University Hospital, Rikshospitalet, Oslo, Norway
| | | | - Vladislav Kuzovkov
- St. Petersburg ENT and Speech Research Institute, St. Petersburg, Russia
| | - Martin Leinung
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Yongxin Li
- Department of Otorhinolaryngology Head and Neck Surgery, Beijing Tongren Hospital, Capital Medical University, Beijing, China
- Key Laboratory of Otolaryngology Head and Neck Surgery (Capital Medical University), Ministry of Education, Beijing, China
| | - Andreas Loth
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | - Astrid Magele
- Ear, Nose and Throat Department, University Clinic St. Poelten, Karl Landsteiner Private University, St. Poelten, Austria
| | - Robert Mlynski
- Department of Otorhinolaryngology, Head and Neck Surgery, “Otto Körner” Rostock University Medical Center, Rostock, Germany
| | - Joachim Mueller
- Klinik und Poliklinik für Hals-, Nasen- und Ohrenheilkunde, Ludwig-Maximilians-Universitat Munchen, Munchen, Germany
| | - Lorne Parnes
- Department of Otolaryngology-Head and Neck Surgery, Western University, London, ON, Canada
| | - Andreas Radeloff
- Division of Oto-Rhino-Laryngology, Evangelisches Krankenhaus Oldenburg, Research Center of Neurosensory Sciences, University Oldenburg, Oldenburg, Germany
| | - Chris Raine
- Bradford Royal Infirmary Yorkshire Auditory Implant Center, Bradford, United Kingdom
| | - Gunesh Rajan
- Department of Otolaryngology, Head and Neck Surgery, Luzerner Kantonsspital, Luzern, Medical Sciences Department of Health Sciences and Medicine. University of Lucerne, Luzern, Switzerland. Otolaryngology, Head & Neck Surgery, Medical School University of Western Australia, Perth, WA, Australia
| | - Joachim Schmutzhard
- Department of Otorhinolaryngology, Medical University of Innsbruck, Innsbruck, Austria
| | - Henryk Skarzynski
- Department of Teleaudiology and Screening, World Hearing Center of the Institute of Physiology and Pathology of Hearing, Kajetany, Poland
| | - Piotr H. Skarzynski
- Department of Teleaudiology and Screening, World Hearing Center of the Institute of Physiology and Pathology of Hearing, Kajetany, Poland
| | - Georg Sprinzl
- Ear, Nose and Throat Department, University Clinic St. Poelten, Karl Landsteiner Private University, St. Poelten, Austria
| | - Hinrich Staecker
- Kansas University Center for Hearing and Balance Disorders, Kansas City, KS, United States
| | - Timo Stöver
- Department of Otolaryngology, Head and Neck Surgery, University Hospital Frankfurt, Frankfurt am Main, Germany
| | | | - Vedat Topsakal
- Department of ENT HNS, University Hospital Brussels, Brussels, Belgium
| | - Shin-Ichi Usami
- Department of Hearing Implant Sciences, Shinshu University School of Medicine, Nagano, Japan
| | - Vincent Van Rompaey
- Department of Otorhinolaryngology Head and Neck Surgery, Antwerp University Hospital, University of Antwerp, Antwerp, Belgium
- Department of Translational Neurosciences, University of Antwerp, Antwerp, Belgium
| | - Nora M. Weiss
- Department of Otorhinolaryngology-Head and Neck Surgery, Ruhr-University Bochum, St. Elisabeth University Hospital Bochum, Bochum, Germany
| | - Wilhelm Wimmer
- Department for ENT, Head and Neck Surgery, Bern University Hospital, Bern, Switzerland
| | - Mario Zernotti
- Catholic University of Córdoba and National University of Córdoba, Córdoba, Argentina
| | - Javier Gavilan
- Hospital Universitario La Paz, Institute for Health Research (IdiPAZ), Madrid, Spain
| |
Collapse
|
18
|
Intracochlear electrode array position and cochlear implant outcomes using the nucleus slim modiolar electrode and the extended round window approach: a follow-up study. Eur Arch Otorhinolaryngol 2022; 279:4735-4743. [PMID: 35041067 PMCID: PMC9474433 DOI: 10.1007/s00405-021-07247-w] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Accepted: 12/28/2021] [Indexed: 01/10/2023]
Abstract
PURPOSE The aim of this study was to evaluate the intracochlear position of the Slim Modiolar Electrode (SME) after insertion via the extended Round Window (eRW) approach, and to correlate this with residual hearing preservation and speech perception outcomes. METHODS Twenty-three adult participants, consecutively implanted with the SME via the eRW approach, were included in this prospective, single-center, observational study. Electrode position was evaluated intra-operatively using X-ray fluoroscopy and TIM measurement, and post-operatively using ultra-high resolution CT. Residual hearing [threshold shift in PTA between pre- and post-operative measurement, relative hearing preservation (RHP%)] and speech perception were evaluated at 2 and 12 months after surgery. RESULTS In each of the 23 participants, complete scala tympani positioning of the electrode array could be achieved. In one participant, an initial tip fold-over was corrected during surgery. Average age at implantation was 63.3 years (SD 13.3, range 28-76) and mean preoperative residual hearing was 81.5 dB. The average post-operative PTA threshold shift was 16.2 dB (SD 10.8) at 2 months post-operatively, corresponding with a RHP% score of 44% (SD 34.9). At 12 months, the average RHP% score decreased to 37%. Postoperative phoneme scores improved from 27.1% preoperatively, to 72.1% and 82.1% at 2 and 12 months after surgery, respectively. CONCLUSION Use of the eRW approach results in an increased likelihood of complete scala tympani insertion when inserting the SME, with subsequent excellent levels of speech perception. However, residual hearing preservation was found to be moderate, possibly as a result of the extended round window approach, emphasizing that it is not an all-purpose approach for inserting this particular electrode array.
Collapse
|
19
|
Fan Y, Zhang D, Banalagay R, Wang J, Noble JH, Dawant BM. Hybrid active shape and deep learning method for the accurate and robust segmentation of the intracochlear anatomy in clinical head CT and CBCT images. J Med Imaging (Bellingham) 2021; 8:064002. [PMID: 34853805 DOI: 10.1117/1.jmi.8.6.064002] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2020] [Accepted: 11/08/2021] [Indexed: 11/14/2022] Open
Abstract
Purpose: Robust and accurate segmentation methods for the intracochlear anatomy (ICA) are a critical step in the image-guided cochlear implant programming process. We have proposed an active shape model (ASM)-based method and a deep learning (DL)-based method for this task, and we have observed that the DL method tends to be more accurate than the ASM method while the ASM method tends to be more robust. Approach: We propose a DL-based U-Net-like architecture that incorporates ASM segmentation into the network. A quantitative analysis is performed on a dataset that consists of 11 cochlea specimens for which a segmentation ground truth is available. To qualitatively evaluate the robustness of the method, an experienced expert is asked to visually inspect and grade the segmentation results on a clinical dataset made of 138 image volumes acquired with conventional CT scanners and of 39 image volumes acquired with cone beam CT (CBCT) scanners. Finally, we compare training the network (1) first with the ASM results, and then fine-tuning it with the ground truth segmentation and (2) directly with the specimens with ground truth segmentation. Results: Quantitative and qualitative results show that the proposed method increases substantially the robustness of the DL method while having only a minor detrimental effect (though not significant) on its accuracy. Expert evaluation of the clinical dataset shows that by incorporating the ASM segmentation into the DL network, the proportion of good segmentation cases increases from 60/177 to 119/177 when training only with the specimens and increases from 129/177 to 151/177 when pretraining with the ASM results. Conclusions: A hybrid ASM and DL-based segmentation method is proposed to segment the ICA in CT and CBCT images. Our results show that combining DL and ASM methods leads to a solution that is both robust and accurate.
Collapse
Affiliation(s)
- Yubo Fan
- Vanderbilt University, Department of Computer Science, Nashville, Tennessee, United States
| | | | - Rueben Banalagay
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| | - Jianing Wang
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| | - Jack H Noble
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| | - Benoit M Dawant
- Vanderbilt University, Department of Electrical and Computer Engineering, Nashville, Tennessee, United States
| |
Collapse
|
20
|
Glaubitz C, Liebscher T, Hoppe U. Age-related language performance and device use in children with very early bilateral cochlear implantation. Int J Pediatr Otorhinolaryngol 2021; 147:110780. [PMID: 34052573 DOI: 10.1016/j.ijporl.2021.110780] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Revised: 04/21/2021] [Accepted: 05/17/2021] [Indexed: 11/19/2022]
Abstract
OBJECTIVES Paediatric cochlear implantation within the first year of life results in better outcome in auditory and language skills. Beside individual, audiological and social factors, quantity and quality of daily cochlear implant (CI) use also seem to be an influencing factor. The purpose of this study was to evaluate children's early receptive and expressive language performance considering bilingual language development as well as quantity and quality of daily CI use and intraoperative objective measurements. METHODS The retrospective analysis included data from 35 very early bilaterally cochlear-implanted children (age at CI M = 8.4 ± 1.5 months). Language performance was assessed by the German standardised test SETK-2 (age at testing M = 29.4 ± 4.0 months). The CI system-integrated data-logging was analysed with regard to daily CoilOn-time, CoilOff and exposure to classified listening scenes. Intraoperatively measured thresholds of evoked compound action potentials (T-ECAPs) were analysed to ensure CI functionality. RESULTS The cohort showed language performance within the normal range for word comprehension, sentence comprehension and word production, level of sentence production was reduced. Overall, bilingual children performed less well than monolingual children. Intraoperative T-ECAPs were recorded for the total cohort and no anomalies were detected. Children used their CI for about 8.7 ± 1.4 h per day, most of this time spent in a quiet environment (38%). Word production was significantly correlated with the daily duration of CI use (CoilOn-time) and with exposure to the listening environment Speech. No correlation was found between number of daily coil disconnections (CoilOff) and language performance. CONCLUSION Very early bilateral cochlear implantation may result in age-appropriate language skills already at the age of 2 years. Monolingualism seems to a better condition for early language development with CI than bilingualism. Especially for word production, the daily duration of CI use and exposure time in a speech-characterised environment seem to be additional positive factors. Monitoring the data-logs should be one important focus of professionals during the postoperative rehabilitation process to detect potential benefits and risks. These findings should be integrated into rehabilitative therapy and parent counselling.
Collapse
|
21
|
Rupp R, Hornung J, Balk M, Sievert M, Müller S, Hoppe U, Iro H, Gostian AO. Cochlear Implantation Following Explorative Tympanotomy in Patients With Sudden Sensorineural Hearing Loss: Surgical Features and Audiological Outcomes. EAR, NOSE & THROAT JOURNAL 2021; 102:NP277-NP283. [PMID: 33848205 DOI: 10.1177/01455613211009141] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/15/2022] Open
Abstract
OBJECTIVE To investigate the anatomical status of the round window niche and hearing outcome of cochlear implantation (CI) after explorative tympanotomy (ExT) with sealing of the round window membrane in patients with sudden sensorineural hearing loss at a tertiary referral medical center. METHODS Between January 1, 2007, and July 30, 2020, 1602 patients underwent CI at our department. Out of these, all patients previously treated by ExT with sealing of the round window membrane because of unilateral sudden hearing loss were included in the study. A retrospective chart review was conducted concerning method of round window membrane sealing, intraoperative findings during CI, postoperative imaging, and hearing results. RESULTS Twenty one patients (9 females; 8 right ears; 54.3 years [± 12.9 years]) underwent ExT with sealing of the round window membrane with subsequent CI after 26.6 months (± 32.9 mo) on average. During CI, in 76% of cases (n = 16), the round window niche was blocked by connective tissue due to the previous intervention but could be removed completely in all cases. The connective tissue itself and its removal had no detrimental effects on the round window membrane. Postoperative computed tomography scan showed no electrode dislocation. Mean postoperative word recognition score after 3 months was 57.4% (± 17.2%) and improved significantly to 73.1% (± 16.4%, P = .005) after 2 years. CONCLUSION Performing CI after preceding ExT, connective tissue has to be expected blocking the round window niche. Remaining tissue can be removed safely and does not alter the round window membrane allowing for a proper electrode insertion. Short- and long-term hearing results are satisfactory. Consequently, ExT with sealing of the round window membrane in patients with sudden sensorineural hearing loss does not impede subsequent CI that can still be performed safely.
Collapse
Affiliation(s)
- Robin Rupp
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, 9171Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Joachim Hornung
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, 9171Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Matthias Balk
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, 9171Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Matti Sievert
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, 9171Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Sarina Müller
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, 9171Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Ulrich Hoppe
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, 9171Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Heinrich Iro
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, 9171Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| | - Antoniu-Oreste Gostian
- Department of Otorhinolaryngology, Head and Neck Surgery, Medical Faculty, 9171Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Erlangen, Germany
| |
Collapse
|