1
|
Akramipour R, Babaei H, Castru-Cayllaha F, Golpayegani MR, Fattahi N, Fattahi F. Sensitive determination of daunorubicin in plasma of children with leukemia using pH-switchable deep eutectic solvents and HPLC-UV analysis. Heliyon 2024; 10:e23532. [PMID: 38173485 PMCID: PMC10761566 DOI: 10.1016/j.heliyon.2023.e23532] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/26/2023] [Revised: 12/05/2023] [Accepted: 12/05/2023] [Indexed: 01/05/2024] Open
Abstract
An environmental friendly, fast, easy and inexpensive liquid-liquid microextraction (LLME) in combination with pH-switchable deep eutectic solvent (DES) method followed by HPLC was investigated for the separation and determination of daunorubicin (DNR) in human plasma samples. For this purpose, first, 9 DESs were prepared based on previous studies and their switchability in aqueous solution was evaluated by changing the pH. Non-switchable DESs were discarded and switchable DESs were used to extract DNR. The parameters affecting the extraction efficiency were optimized (DES type, volume of DES, concentration of KOH, volume of HCl, salt addition and extraction time). After optimizing the conditions and drawing the calibration curve, figures of merit were calculated. Relative standard deviations (%RSDs) based on 7 replicate with 50 μg L-1 of DNR in plasma were 2.7 for intra-day and 4.8 % for inter-day. A wide linear range from 0.15 to 200 μg L-1 was obtained. The detection limit of the method based on signal-to-noise 3 and the quantification limit of the method based on signal-to-noise 10 were 0.05 and 0.15, respectively. After spiking plasma samples with different concentrations of DNR, relative recoveries were obtained in the range of 91.0-107.8 %.
Collapse
Affiliation(s)
- Reza Akramipour
- School of Medical, Kermanshah University of Medical Sciences, Kermanshah, Iran
- Clinical Research Development Center, Imam Khomeini and Mohammad Kermanshahi and Farabi Hospitals, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Homa Babaei
- School of Medical, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | | | - Mohammad Reza Golpayegani
- School of Medical, Kermanshah University of Medical Sciences, Kermanshah, Iran
- Clinical Research Development Center, Imam Khomeini and Mohammad Kermanshahi and Farabi Hospitals, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Nazir Fattahi
- Research Center for Environmental Determinants of Health (RCEDH), Health Institute, Kermanshah University of Medical Sciences, Kermanshah, Iran
| | - Farshad Fattahi
- Research Center for Environmental Determinants of Health (RCEDH), Health Institute, Kermanshah University of Medical Sciences, Kermanshah, Iran
| |
Collapse
|
2
|
Maliszewska O, Treder N, Olędzka II, Kowalski P, Miękus N, Bączek T, Rodzaj W, Bień E, Krawczyk MA, Plenis A. Sensitive Analysis of Idarubicin in Human Urine and Plasma by Liquid Chromatography with Fluorescence Detection: An Application in Drug Monitoring. Molecules 2020; 25:E5799. [PMID: 33316898 PMCID: PMC7764277 DOI: 10.3390/molecules25245799] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/12/2020] [Accepted: 12/07/2020] [Indexed: 11/16/2022] Open
Abstract
A new approach for the sensitive, robust and rapid determination of idarubicin (IDA) in human plasma and urine samples based on liquid chromatography with fluorescence detection (LC-FL) was developed. Satisfactory chromatographic separation of the analyte after solid-phase extraction (SPE) was performed on a Discovery HS C18 analytical column using a mixture of acetonitrile and 0.1% formic acid in water as the mobile phase in isocratic mode. IDA and daunorubicin hydrochloride used as an internal standard (I.S.) were monitored at the excitation and emission wavelengths of 487 and 547 nm, respectively. The method was validated according to the FDA and ICH guidelines. The linearity was confirmed in the range of 0.1-50 ng/mL and 0.25-200 ng/mL, while the limit of detection (LOD) was 0.05 and 0.125 ng/mL in plasma and urine samples, respectively. The developed LC-FL method was successfully applied for drug determinations in human plasma and urine after oral administration of IDA at a dose of 10 mg to a patient with highly advanced alveolar rhabdomyosarcoma (RMA). Moreover, the potential exposure to IDA present in both fluids for healthcare workers and the caregivers of patients has been evaluated. The present LC-FL method can be a useful tool in pharmacokinetic and clinical investigations, in the monitoring of chemotherapy containing IDA, as well as for sensitive and reliable IDA quantitation in biological fluids.
Collapse
Affiliation(s)
- Olga Maliszewska
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Hallera 107, 80-416 Gdańsk, Poland; (O.M.); (N.T.); (I.O.); (P.K.); (N.M.); (T.B.)
| | - Natalia Treder
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Hallera 107, 80-416 Gdańsk, Poland; (O.M.); (N.T.); (I.O.); (P.K.); (N.M.); (T.B.)
| | - IIona Olędzka
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Hallera 107, 80-416 Gdańsk, Poland; (O.M.); (N.T.); (I.O.); (P.K.); (N.M.); (T.B.)
| | - Piotr Kowalski
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Hallera 107, 80-416 Gdańsk, Poland; (O.M.); (N.T.); (I.O.); (P.K.); (N.M.); (T.B.)
| | - Natalia Miękus
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Hallera 107, 80-416 Gdańsk, Poland; (O.M.); (N.T.); (I.O.); (P.K.); (N.M.); (T.B.)
| | - Tomasz Bączek
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Hallera 107, 80-416 Gdańsk, Poland; (O.M.); (N.T.); (I.O.); (P.K.); (N.M.); (T.B.)
| | - Wojciech Rodzaj
- Department of Toxicology, Medical University of Gdańsk, Hallera 107, 80-416 Gdańsk, Poland;
| | - Ewa Bień
- Department of Pediatrics, Hematology and Oncology, Medical University Gdańsk, Dębinki 7, 80-210 Gdańsk, Poland; (E.B.); (M.A.K.)
| | - Małgorzata Anna Krawczyk
- Department of Pediatrics, Hematology and Oncology, Medical University Gdańsk, Dębinki 7, 80-210 Gdańsk, Poland; (E.B.); (M.A.K.)
| | - Alina Plenis
- Department of Pharmaceutical Chemistry, Medical University of Gdańsk, Hallera 107, 80-416 Gdańsk, Poland; (O.M.); (N.T.); (I.O.); (P.K.); (N.M.); (T.B.)
| |
Collapse
|
3
|
Alizadeh M, Azar PA, Mozaffari SA, Karimi-Maleh H, Tamaddon AM. Evaluation of Pt,Pd-Doped, NiO-Decorated, Single-Wall Carbon Nanotube-Ionic Liquid Carbon Paste Chemically Modified Electrode: An Ultrasensitive Anticancer Drug Sensor for the Determination of Daunorubicin in the Presence of Tamoxifen. Front Chem 2020; 8:677. [PMID: 32974271 PMCID: PMC7466574 DOI: 10.3389/fchem.2020.00677] [Citation(s) in RCA: 17] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2020] [Accepted: 06/30/2020] [Indexed: 12/11/2022] Open
Abstract
Measuring the concentration of anticancer drugs in pharmacological and biological samples is a very useful solution to investigate the effectiveness of these drugs in the chemotherapy process. A Pt,Pd-doped, NiO-decorated SWCNTs (Pt,Pd-NiO/SWCNTs) nanocomposite was synthesized using a one-pot procedure and combining chemical precipitation and ultrasonic sonochemical methods and subsequently characterized by TEM and EDS analysis methods. The analyses results showed the high purity and good distribution of elements and the ~10-nm diameter of the Pt,Pd-NiO nanoparticle decorated on the surface of the SWCNTs with a diameter of about 20-30 nm. Using a combination of Pt,Pd-NiO/SWCNTs and 1-butyl-2,3-dimethylimidazolium tetrafluoroborate (1B23DTFB) in a carbon paste (CP) matrix, Pt,Pd-NiO/SWCNTs/1B23DTFB/CP was fabricated as a highly sensitive analytical tool for the electrochemical determination of daunorubicin in the concentration range of 0.008-350 μM with a detection limit of 3.0 nM. Compared to unmodified CP electrodes, the electro-oxidation process of daunorubicin has undergone significant improvements in current (about 9.8 times increasing in current) and potential (about 110 mV) decreasing in potential). It is noteworthy that the designed sensor can well measure daunorubicin in the presence of tamoxifen (two breast anticancer drugs with a ΔE = 315 mV. According to the real sample analysis data, the Pt,Pd-NiO/SWCNTs/1B23DTFB/CP has proved to be a promising methodology for the analysis and measuring of daunorubicin and tamoxifen in real (e.g., pharmaceutical) samples.
Collapse
Affiliation(s)
- Marzieh Alizadeh
- Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Parviz Aberoomand Azar
- Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran
| | - Sayed Ahmad Mozaffari
- Thin Layer and Nanotechnology Laboratory, Department of Chemical Technologies, Iranian Research Organization for Science and Technology (IROST), Tehran, Iran
| | - Hassan Karimi-Maleh
- Laboratory of Nanotechnology, Department of Chemical Engineering, Quchan University of Technology, Quchan, Iran
| | - Ali-Mohammad Tamaddon
- Center for Nanotechnology in Drug Delivery, School of Pharmacy, Shiraz University of Medical Sciences, Shiraz, Iran
| |
Collapse
|
4
|
Eksin E, Senturk H, Zor E, Bingol H, Erdem A. Carbon quantum dot modified electrodes developed for electrochemical monitoring of Daunorubicin-DNA interaction. J Electroanal Chem (Lausanne) 2020. [DOI: 10.1016/j.jelechem.2020.114011] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022]
|
5
|
Electrochemical monitoring of biointeraction by graphene-based material modified pencil graphite electrode. Biosens Bioelectron 2017; 92:207-214. [DOI: 10.1016/j.bios.2017.02.016] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2016] [Revised: 02/09/2017] [Accepted: 02/10/2017] [Indexed: 01/12/2023]
|
6
|
KOZIOLOVA E, JANOUSKOVA O, CHYTIL P, STUDENOVSKY M, KOSTKA L, ETRYCH T. Nanotherapeutics With Anthracyclines: Methods of Determination and Quantification of Anthracyclines in Biological Samples. Physiol Res 2015; 64:S1-10. [DOI: 10.33549/physiolres.933140] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/15/2022] Open
Abstract
Anthracyclines, e.g. doxorubicin, pirarubicin, are widely used as cytostatic agents in the polymer nanotherapeutics designed for the highly effective antitumor therapy with reduced side effects. However, their precise dosage scheme needs to be optimized, which requires an accurate method for their quantification on the cellular level in vitro during nanocarrier development and in body fluids and tissues during testing in vivo. Various methods detecting the anthracycline content in biological samples have already been designed. Most of them are highly demanding and they differ in exactness and reproducibility. The cellular uptake and localization is predominantly observed and determined by microscopy techniques, the anthracycline content is usually quantified by chromatographic analysis using fluorescence detection. We reviewed and compared published methods concerning the detection of anthracycline nanocarriers.
Collapse
Affiliation(s)
- E. KOZIOLOVA
- Institute of Macromolecular Chemistry, Academy of Sciences of the Czech Republic, Prague, Czech Republic
| | | | | | | | | | | |
Collapse
|
7
|
Prakash J, Mishra AK. Quantification of doxorubicin in biofluids using white light excitation fluorescence. JOURNAL OF BIOPHOTONICS 2014; 7:607-616. [PMID: 23585121 DOI: 10.1002/jbio.201300001] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/01/2013] [Revised: 02/07/2013] [Accepted: 03/08/2013] [Indexed: 06/02/2023]
Abstract
A fiber optic spectrometer setup was designed for white light excitation fluorescence 'WLEF' based measurements. Using this setup, two different analytical methods, a self referencing ratio-metric and a difference WLEF methods, were developed for the quantification of doxorubicin (DXR) in biofluids. It was seen that Acetonitrile (ACN) acts as an efficient and transparent extracting medium for DXR. The figures of merit and the percent recoveries of DXR in blood serum, even in presence of external fluorophores and in urine samples are comparable with existing analytical methods. The compact spectrometer is expected to be useful for easy quantification of fluorescent pharmaceuticals in biofluids.
Collapse
Affiliation(s)
- John Prakash
- Department of Chemistry, Indian Institute of Technology, Madras, Chennai, 600036, India
| | | |
Collapse
|
8
|
Tian J, Liu S, Liu Z, Yang J, Zhu J, Qiao M, Hu X. Fluorescence quenching and spectrophotometric methods for the determination of daunorubicin with meso-tera (4-sulphophenyl) porphyrin as probe. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2013; 120:7-13. [PMID: 24177862 DOI: 10.1016/j.saa.2013.10.014] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 06/18/2013] [Revised: 09/29/2013] [Accepted: 10/04/2013] [Indexed: 06/02/2023]
Abstract
In this work, a synthetic meso-tera (4-sulfophenyl) porphyrin (TPPS4) was used as a probe to determine daunorubicin (DNR) by fluorescence quenching and spectrophotometric methods. At pH 4.6 potassium acid phthalate-NaOH buffer solution, a 1:1 complex of DNR interacted with TPPS4 formed via the electrostatic attractions and hydrophobic interactions, thus resulted in TPPS4 fluorescence quenching and absorption spectra change. The maximum excitation wavelength (λex) and the maximum emission wavelength (λem) are 435 nm and 672 nm, respectively. The fluorescence quenching values (ΔF) are the good linear relationship to the concentration of DNR in the range of 0.8-6.0 mgL(-1). The method exhibits high sensitivity with the detection limit (3σ) being 27.0 ng mL(-1). Meanwhile, a decrease of absorbance is detected at 433 nm with the appearance of a new absorption peak at 420 nm. The optimum reaction conditions, influencing factors and the effect of coexisting substances have been investigated in our experiment. The results showed that the method had a good selectivity and could be applied to determine DNR in serum and urine samples. In addition, the combine ratio between DNR and TPPS4 was measured and the charge distribution before and after reaction was calculated by quantum chemistry calculation AM1 method. The type of fluorescence quenching was discussed by the absorption spectra change, Stern-Volmer plots and fluorescence lifetime determination.
Collapse
Affiliation(s)
- Jing Tian
- Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Shaopu Liu
- Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Zhongfang Liu
- Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Jidong Yang
- College of Chemical and Environmental Engineering, Chongqing Three Gorges University, Wanzhou, Chongqing 404100, China
| | - Jinghui Zhu
- Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Man Qiao
- Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China
| | - Xiaoli Hu
- Key Laboratory on Luminescence and Real-Time Analysis, Ministry of Education, School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China.
| |
Collapse
|
9
|
Sanli S, Akmese B, Sanli N, Ozkan SA. A Novel RP-LC Method for Determination of pK a Values of Some Anticancer Agents and Their Assay. Chromatographia 2013. [DOI: 10.1007/s10337-013-2450-6] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
10
|
Ribeiro JA, Silva F, Pereira CM. Electrochemical Study of the Anticancer Drug Daunorubicin at a Water/Oil Interface: Drug Lipophilicity and Quantification. Anal Chem 2013; 85:1582-90. [DOI: 10.1021/ac3028245] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Affiliation(s)
- José A. Ribeiro
- Faculdade de Ciências da Universidade
do Porto, Departamento de Química e Bioquímica, Centro de Investigação em Química, Linha 4, Rua do Campo Alegre 687, 4169-007 Porto, Portugal
| | - F. Silva
- Faculdade de Ciências da Universidade
do Porto, Departamento de Química e Bioquímica, Centro de Investigação em Química, Linha 4, Rua do Campo Alegre 687, 4169-007 Porto, Portugal
| | - Carlos M. Pereira
- Faculdade de Ciências da Universidade
do Porto, Departamento de Química e Bioquímica, Centro de Investigação em Química, Linha 4, Rua do Campo Alegre 687, 4169-007 Porto, Portugal
| |
Collapse
|
11
|
A sensitive sensor for anthraquinone anticancer drugs and hsDNA based on CdTe/CdS quantum dots fluorescence reversible control. Colloids Surf A Physicochem Eng Asp 2011. [DOI: 10.1016/j.colsurfa.2011.08.037] [Citation(s) in RCA: 50] [Impact Index Per Article: 3.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/20/2022]
|
12
|
Maudens KE, Stove CP, Lambert WE. Quantitative liquid chromatographic analysis of anthracyclines in biological fluids. J Chromatogr B Analyt Technol Biomed Life Sci 2011; 879:2471-86. [PMID: 21840776 DOI: 10.1016/j.jchromb.2011.07.010] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2011] [Revised: 07/01/2011] [Accepted: 07/07/2011] [Indexed: 10/18/2022]
Abstract
Anthracyclines are amongst the most widely used drugs in oncology, being part of the treatment regimen in most patients receiving systemic chemotherapy. This review provides a comprehensive summary of the sample preparation techniques and chromatographic methods that have been developed during the last two decades for the analysis of the 4 most administered anthracyclines, doxorubicin, epirubicin, daunorubicin and idarubicin in plasma, serum, saliva or urine, within the context of clinical and pharmacokinetic studies or for assessing occupational exposure. Following deproteinization, liquid-liquid extraction, solid phase extraction or a combination of these techniques, the vast majority of methods utilizes reversed-phase C18 stationary phases for liquid chromatographic separation, followed by fluorescence detection, or, more recently, tandem mass spectrometric detection. Some pros and cons of the different techniques are addressed, in addition to potential pitfalls that may be encountered in the analysis of this class of compounds.
Collapse
Affiliation(s)
- Kristof E Maudens
- Toxicological Centre, Department of Pharmaceutical Sciences, University of Antwerp, Universiteitsplein 1, 2610 Wilrijk-Antwerp, Belgium
| | | | | |
Collapse
|
13
|
Sottani C, Leoni E, Porro B, Montagna B, Amatu A, Sottotetti F, Quaretti P, Poggi G, Minoia C. Validation of an LC-MS/MS method for the determination of epirubicin in human serum of patients undergoing drug eluting microsphere-transarterial chemoembolization (DEM-TACE). J Chromatogr B Analyt Technol Biomed Life Sci 2009; 877:3543-8. [PMID: 19783235 DOI: 10.1016/j.jchromb.2009.08.054] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/15/2009] [Revised: 08/04/2009] [Accepted: 08/25/2009] [Indexed: 10/20/2022]
Abstract
Drug Eluting Microsphere-Transarterial Chemoembolization (DEM-TACE) is a new delivery system to administrate drugs in a controlled manner useful for application in the chemoembolization of colorectal cancer metastases to the liver. DEM-TACE is focused to obtain higher concentrations of the drug to the tumor with lower systemic concentrations than traditional cancer chemotherapy. Therefore a specific, precise and sensitive LC-ESI-MS/MS assay procedure was properly designed to detect and quantify epirubicin at the concentrations expected from a transarterial chemoembolization with microspheres. Serum samples were kept acidic (pH approximately of 3.5) and sample preparation consisted of a solid phase extraction (SPE) procedure with HLB OASIS cartridges using a methylene chloride/2-propanol/methanol mixture solution to recover epirubicin. The analyses consisted of reversed-phase high-performance liquid chromatography (rp-HPLC) coupled with tandem mass spectrometry (MS/MS). Accuracy, precision and matrix effect of this procedure were carried out by analyzing four quality control samples (QCs) on five separate days. The validation parameters were assessed by recovery studies of spiked serum samples. Recoveries were found to vary between 92 and 98% at the QC levels (5, 40, 80 and 150 microg/L) with relative standard deviation (RSD) always less than 3.7%. The limit of detection (LOD) was set at 1 microg/L. The developed procedure has been also applied to investigate the different capability of two types of commercially available microspheres to release epirubicin into the human circulatory system.
Collapse
Affiliation(s)
- Cristina Sottani
- Laboratory for Environmental and Toxicological Testing, IRCCS Pavia, S. Maugeri Foundation, via S. Maugeri 10, Pavia, Italy.
| | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Shakalisava Y, Regan F. CE separation approaches for combinations of anthracyclines and taxanes. Electrophoresis 2009; 30:3110-3113. [DOI: 10.1002/elps.200900097] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
|
15
|
Rapid analysis of anthracycline antibiotics doxorubicin and daunorubicin by microchip capillary electrophoresis. Microchem J 2009. [DOI: 10.1016/j.microc.2009.03.005] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022]
|
16
|
Highly sensitive detection of daunorubicin based on carbon nanotubes–drug supramolecular interaction. Electrochem commun 2009. [DOI: 10.1016/j.elecom.2008.10.045] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022] Open
|
17
|
Whitaker G, Lillquist A, Pasas SA, O'Connor R, Regan F, Lunte CE, Smyth MR. CE-LIF method for the separation of anthracyclines: application to protein binding analysis in plasma using ultrafiltration. J Sep Sci 2008; 31:1828-33. [PMID: 18461567 DOI: 10.1002/jssc.200700629] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
Abstract
Anthracyclines are chemotherapeutic drugs that are widely used in the treatment of cancers such as lung and ovarian cancers. The simultaneous determination of the anthracyclines, daunorubicin, doxorubicin and epirubicin, was achieved using CE coupled to LIF, with an excitation and emission wavelength of 488 and 560 nm, respectively. Using a borate buffer (105 mM, pH 9.0) and 30% MeOH, a stable and reproducible separation of the three anthracyclines was obtained. The method developed was shown to be capable of monitoring the therapeutic concentrations (50-50 000 ng/mL) of anthracyclines. LODs of 10 ng/mL, calculated at an S/N = 3, were achieved. Using the CE method developed, the in vitro protein binding to plasma was measured by ultrafiltration, and from this investigation the estimated protein binding was determined to be in the range of 77-94%.
Collapse
Affiliation(s)
- Gillian Whitaker
- R. N. Adams Institute of Bioanalytical Chemistry, University of Kansas, KS, USA
| | | | | | | | | | | | | |
Collapse
|
18
|
Liu S, Wang F, Liu Z, Hu X, Yi A, Duan H. Resonance Rayleigh scattering spectra for studying the interaction of anthracycline antineoplastic antibiotics with some anionic surfactants and their analytical applications. Anal Chim Acta 2007; 601:101-7. [PMID: 17904475 DOI: 10.1016/j.aca.2007.08.043] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/21/2007] [Revised: 08/05/2007] [Accepted: 08/21/2007] [Indexed: 10/22/2022]
Abstract
In pH 5.8 acidic medium, the anionic surfactants such as sodium dodecyl sulfate (SDS), sodium dodecyl benzene sulfonate (SDBS) or sodium dodecyl sulfonate (SLS) can react with anthracycline antibiotics such as epirubicin (EPI), daunorubicin (DNR) or mitoxantrone (MXT) to form ion-association complexes, which lead to a great enhancement of resonance Rayleigh scattering (RRS) intensity and appearances of new RRS spectra. The maximum RRS peaks are situated at 313 nm for SDS-DNR and SDS-EPI system, 296 nm for SDS-MXT system. The linear ranges and detection limits for EPI, DNR and MXT are 0.26-20.0, 0.25-20.0, 0.14-10.0 and 0.074, 0.078, 0.042 microgmL(-1), respectively. In this paper, the characteristics of the absorption, fluorescence and RRS spectra of the reaction products are studied as well as the optimum reaction conditions and analytical chemistry properties. A sensitive, simple and rapid RRS method for the determination of anthracycline anticancer antibiotics has been developed.
Collapse
Affiliation(s)
- Shaopu Liu
- School of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, PR China
| | | | | | | | | | | |
Collapse
|
19
|
Gao D, Hu J, Yang M, Li Q. Determination of daunomycin at a novel COOH/indium tin oxide ion implantation-modified electrode. Anal Biochem 2006; 358:70-5. [PMID: 16996022 DOI: 10.1016/j.ab.2006.06.008] [Citation(s) in RCA: 21] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/02/2006] [Revised: 06/04/2006] [Accepted: 06/06/2006] [Indexed: 10/24/2022]
Abstract
A novel COOH+ ion implantation-modified indium tin oxide (COOH/ITO) electrode was prepared for the first time and applied for determination of daunomycin (or daunorubicin [DNR]). The electrode showed higher catalytic activity than bare ITO electrode with good reproducibility and stability. The determination condition of linear voltammetry was optimized. A calibration curve was obtained over the range 2.0 x 10(-7) to 5.0 x 10(-6)mol/L, with a correlation coefficient of 0.9909 and a limit of detection of 1.0 x 10(-7)mol/L. The selectivity of the electrode was illustrated by determination of DNR in samples prepared of urine. X-ray photoelectron spectroscopy (XPS) analysis results showed that the implanted COOH+ maintained characteristics of organic group -COOH. A field emission-scanning electron microscope (FSEM) result showed that the implanted surface caused defects and partial dislocations and formed many active centers.
Collapse
Affiliation(s)
- DongMei Gao
- Department of Chemistry, Beijing Normal University, Beijing 100875, China
| | | | | | | |
Collapse
|
20
|
Hahn Y, Lee HY. Electrochemical behavior and square wave voltammetric determination of doxorubicin hydrochloride. Arch Pharm Res 2004; 27:31-4. [PMID: 14969334 DOI: 10.1007/bf02980041] [Citation(s) in RCA: 54] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/21/2022]
Abstract
The electrochemical behavior of doxorubicin hydrochloride was investigated by cyclic voltammetry (CV) and square wave voltammetry (SWV). From CV and SWV studies of doxorubicin hydrochloride in the acetate buffers of various pH values, it was found that protons were involved in the reduction of the antibiotic at the H+/e- ratio at one (deltaEp/pH = -53 approximately -61 mV at 23 degrees C), proposing the electrochemical reduction of the quinone moiety in its anthraquinone aglycone. Its electrochemical behavior was pseudo-reversible in the acetate buffer of pH 3.5 by exhibiting the well-defined single cathodic and anodic waves and the ratio of Ip(a)/Ip(c) at approximately one over the scan rates of 10 approximately 100 mV/s. Fast and sensitive SWV showing a single peak of doxorubicin has been applied for its quantitative analysis using an acetate buffer of pH 3.5. A linearity was obtained when the peak currents (Ip) were plotted against concentrations of doxorubicin in the range of 5.0 x 10(-7) M approximately 1.0 x 10(-5) M with a detection limit of 1.0 x 10(-7) M.
Collapse
Affiliation(s)
- Younghee Hahn
- Department of Chemistry, Sangmyung University, Seoul 110-743, Korea.
| | | |
Collapse
|
21
|
Hu Q, Hu G, Zhou T, Fang Y. Determination of dissociation constants of anthrocycline by capillary zone electrophoresis with amperometric detection. J Pharm Biomed Anal 2003; 31:679-84. [PMID: 12644194 DOI: 10.1016/s0731-7085(02)00681-7] [Citation(s) in RCA: 16] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
Abstract
Although daunorubicin, pharmorubicin and idarubicin are important drugs in medical and in pharmaceutical research, the dissociation constants (K(a)) of these substances are frequently not known. A method based on a non-linear model enabling the efficient determination of the K(a) of the three drugs by capillary zone electrophoresis with amperometric detection (CZE-AD) has been demonstrated. The pK(a) values obtained through the method were in agreement with the values by typical spectrophotometric method.
Collapse
Affiliation(s)
- Qin Hu
- Department of Physiology and Pharmacology, Nanjing Medical University, Jiangsu 210029, Nanjing, People's Republic of China
| | | | | | | |
Collapse
|
22
|
Abstract
The focus of this article is amperometric and voltammetric detection coupled with capillary electrophoresis. Fundamental concepts and progress in the field of capillary electrophoresis with electrochemical detection (CEEC) that have occurred within the past three years, including new methodologies and unique applications, are highlighted. This review contains 95 references.
Collapse
Affiliation(s)
- Lisa A Holland
- Department of Chemistry, West Virginia University, Morgantown, WV 26506-6045, USA.
| | | |
Collapse
|
23
|
Zhou T, Yu H, Hu Q, Fang Y. Determination of codeine and its metabolite in human urine by CE with amperometric detection. J Pharm Biomed Anal 2002; 30:13-9. [PMID: 12151061 DOI: 10.1016/s0731-7085(02)00019-5] [Citation(s) in RCA: 31] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
Abstract
The amperometric detection of codeine and its metabolite, morphine following capillary zone electrophoretic separation is described. A carbon-disk electrode used as working electrode for two analytes exhibited a good response at 0.90 V (vs. Ag/AgCl). The optimal conditions of separation and detection were pH 8.4 phosphate buffer solution (0.06 mol x l(-1)), 12 kV for the separation voltage, sample injection at 12 kV for 10 s. The linear ranges were from 3.1 x 10(-7) to 2.5 x 10(-5) mol x l(-1) for codeine and 1.9 x 10(-7) to 1.5 x 10(-5) x mol l(-1) for morphine with a correlation coefficient of 0.9996 and 0.9999, respectively. The detection limits for codeine and morphine were 1.6 x 10(-7) and 6.8 x 10(-8) x mol l(-1). The method developed was successfully applied to the determination of codeine and its metabolite, morphine in the human urine without any other sample pretreatment except filtration, and the results were satisfactory.
Collapse
Affiliation(s)
- Tianshu Zhou
- Department of Chemistry, East China Normal University, 200062, Shanghai, PR China
| | | | | | | |
Collapse
|
24
|
Zagotto G, Gatto B, Moro S, Sissi C, Palumbo M. Anthracyclines: recent developments in their separation and quantitation. JOURNAL OF CHROMATOGRAPHY. B, BIOMEDICAL SCIENCES AND APPLICATIONS 2001; 764:161-71. [PMID: 11817026 DOI: 10.1016/s0378-4347(01)00346-2] [Citation(s) in RCA: 50] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Anthracyclines are among the most widely used anticancer agents. Notwithstanding the large efforts to develop new drugs with a better pharmaceutical profile, daunorubicin, doxorubicin, epirubicin and idarubicin are still the most used in clinical practice. Many efforts are now ongoing to reduce the side effects by using pharmaceutical formulations able to release the drug in the most appropriate way and monitoring the quantity of anthracyclines and their metabolites in the body fluids or tissues frequently and in every patient to maintain the drug concentration within the expected range. This review describes the most recent developments in the separation and quantitation of the above clinically useful drugs, together with their principal metabolites. Some less widely used derivatives will also be considered.
Collapse
Affiliation(s)
- G Zagotto
- Department of Pharmaceutical Sciences, University of Padova, Italy.
| | | | | | | | | |
Collapse
|
25
|
Thormann W, Lurie IS, McCord B, Marti U, Cenni B, Malik N. Advances ofcapillary electrophoresis in clinical and forensic analysis (1999-2000). Electrophoresis 2001; 22:4216-43. [PMID: 11824639 DOI: 10.1002/1522-2683(200111)22:19<4216::aid-elps4216>3.0.co;2-w] [Citation(s) in RCA: 72] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
In this paper, capillary electrophoresis in clinical and forensic analysis is reviewed on the basis of the literature of 1999, 2000 and the first papers in 2001. An overview of progress relevant examples for each major field of application, namely (i) analysis of drug seizures, explosives residues, gunshot residues and inks, (ii) monitoring of drugs, endogenous small molecules and ions in biofluids and tissues, (iii) general screening for serum proteins and analysis of specific proteins (carbohydrate deficient transferrin, alpha1-antitrypsin, lipoproteins and hemoglobins) in biological fluids, and (iv) analysis of nucleic acids and oligonucleotides in biological samples, including oligonucleotide therapeutics, are presented.
Collapse
Affiliation(s)
- W Thormann
- Department of Clinical Pharmacology, University of Bern, Switzerland.
| | | | | | | | | | | |
Collapse
|
26
|
Abstract
This article reviews recent developments in the characterization of antibiotics. Many capillary electrophoretic techniques have been utilized in their analyses, addressing various aspects of quantifying, profiling and monitoring. Sensitive electrochemical and laser-induced fluorescence detection systems have been utilized, demonstrating trace level determinations in clinical settings and in environmental samples. Different sample introduction methods have been explored, enhancing detection sensitivity, or reducing or eliminating sample manipulation prior to injection.
Collapse
Affiliation(s)
- C L Flurer
- Forensic Chemistry Center, U.S. Food and Drug Administration, Cincinnati, OH 45237, USA.
| |
Collapse
|
27
|
Gavenda A, Sevcík J, Psotová J, Bednár P, Barták P, Adamovský P, Simánek V. Determination of anthracycline antibiotics doxorubicin and daunorubicin by capillary electrophoresis with UV absorption detection. Electrophoresis 2001; 22:2782-5. [PMID: 11545408 DOI: 10.1002/1522-2683(200108)22:13<2782::aid-elps2782>3.0.co;2-i] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
Sweeping preconcentration and electrokinetic injection was used for the capillary electrophoretic analysis of trace amounts of biologically active anthracyclines with UV absorption detection. Phosphate buffer (100 mM), pH 2.5, with addition of 40% v/v methanol was used as background electrolyte (BGE). Sodium dodecyl sulfate (150 mM) was added to BGE in the inlet vial as the sweeping agent. The system enables effective separation of anthracyclines as well as cleanup from matrix impurities. Sweeping preconcentration of sample provides an excellent detection limit (1 x 10(-9) mol L(-1)). The method was applied for the determination of therapeutic levels of doxorubicin in real plasma samples.
Collapse
Affiliation(s)
- A Gavenda
- Department of Analytical Chemistry, Palacky University, Olomouc, Czech Republic
| | | | | | | | | | | | | |
Collapse
|