1
|
Metwally H, Agrawal P, Smith R, Liu C, LeBlanc Y, Covey TR, Oleschuk R. Detection of Opioids on Mail/Packages Using Open Port Interface Mass Spectrometry (OPI-MS). JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:2370-2378. [PMID: 33079532 DOI: 10.1021/jasms.0c00295] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Opioids (and their more potent synthetic analogues) are used therapeutically as effective pain killers; however, recreational use and consequent overdoses are implicated in the deaths of thousands of people across the world annually. Trafficking of opioids and other illegal drugs through international mail has become a significant challenge for law enforcement personnel. Hundreds of millions of letters are sorted by the U.S. and Canadian postal services every day. Chemical analysis of this immense volume of mail requires a very fast sampling/detection method. This work explores the use of real-time mass spectrometry analysis with the recently developed Open Port Interface (OPI) for acoustically dispensed nanoliter volume sample droplets, a type of liquid microjunction surface sampling probe, for rapid and easy non-intrusive detection of fentanyl, heroin, and oxycodone. The OPI coupled to mass spectrometry is a novel sample introduction method that allows the rapid analysis of sample surfaces without preparation or modification. Opioids on different packaging materials (e.g., paper, bubble wrap, Ziploc bags) were rapidly (<10 s) interrogated by the OPI, and the sensitivities of the method compared. Furthermore, an opioid surrogate (caffeine) could be facilely detected on envelopes after processing through postal services.
Collapse
Affiliation(s)
- Haidy Metwally
- Department of Chemistry, Queen's University, Kingston, Ontario K7L 3N6, Canada
| | - Prashant Agrawal
- Department of Chemistry, Queen's University, Kingston, Ontario K7L 3N6, Canada
| | - Rachael Smith
- Department of Chemistry, Queen's University, Kingston, Ontario K7L 3N6, Canada
| | - Chang Liu
- SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4 V8, Canada
| | - Yves LeBlanc
- SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4 V8, Canada
| | - Thomas R Covey
- SCIEX, 71 Four Valley Drive, Concord, Ontario L4K 4 V8, Canada
| | - Richard Oleschuk
- Department of Chemistry, Queen's University, Kingston, Ontario K7L 3N6, Canada
| |
Collapse
|
2
|
Nevídalová H, Michalcová L, Glatz Z. Capillary electrophoresis-based immunoassay and aptamer assay: A review. Electrophoresis 2020; 41:414-433. [PMID: 31975407 DOI: 10.1002/elps.201900426] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/19/2019] [Revised: 01/14/2020] [Accepted: 01/15/2020] [Indexed: 12/31/2022]
Abstract
Over the last two decades, the group of techniques called affinity probe CE has been widely used for the detection and the determination of several types of biomolecules with high sensitivity. These techniques combine the low sample consumption and high separation power of CE with the selectivity of the probe to the target molecule. The assays can be defined according to the type of probe used: CE immunoassays, with an antibody as the probe, or aptamer-based CE, with an aptamer as the probe. Immunoassays are generally divided into homogeneous and heterogeneous groups, and homogeneous variant can be further performed in competitive or noncompetitive formats. Interacting partners are free in solution at homogeneous assay, as opposed to heterogeneous analyses, where one of them is immobilized onto a solid support. Highly sensitive fluorescence, chemiluminescence or electrochemical detections were typically used in this type of study. The use of the aptamers as probes has several advantages over antibodies such as shorter generation time, higher thermal stability, lower price, and lower variability. The aptamer-based CE technique was in practice utilized for the determination of proteins in biological fluids and environmentally or clinically important small molecules. Both techniques were also transferred to microchip. This review is focused on theoretical principles of these techniques and a summary of their applications in research.
Collapse
Affiliation(s)
- Hana Nevídalová
- Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
| | - Lenka Michalcová
- Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
| | - Zdeněk Glatz
- Department of Biochemistry, Faculty of Science, Masaryk University, Brno, Czech Republic
| |
Collapse
|
3
|
Posch TN, Pütz M, Martin N, Huhn C. Electromigrative separation techniques in forensic science: combining selectivity, sensitivity, and robustness. Anal Bioanal Chem 2014; 407:23-58. [PMID: 25381613 DOI: 10.1007/s00216-014-8271-0] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2014] [Revised: 10/12/2014] [Accepted: 10/14/2014] [Indexed: 01/27/2023]
Abstract
In this review we introduce the advantages and limitations of electromigrative separation techniques in forensic toxicology. We thus present a summary of illustrative studies and our own experience in the field together with established methods from the German Federal Criminal Police Office rather than a complete survey. We focus on the analytical aspects of analytes' physicochemical characteristics (e.g. polarity, stereoisomers) and analytical challenges including matrix tolerance, separation from compounds present in large excess, sample volumes, and orthogonality. For these aspects we want to reveal the specific advantages over more traditional methods. Both detailed studies and profiling and screening studies are taken into account. Care was taken to nearly exclusively document well-validated methods outstanding for the analytical challenge discussed. Special attention was paid to aspects exclusive to electromigrative separation techniques, including the use of the mobility axis, the potential for on-site instrumentation, and the capillary format for immunoassays. The review concludes with an introductory guide to method development for different separation modes, presenting typical buffer systems as starting points for different analyte classes. The objective of this review is to provide an orientation for users in separation science considering using capillary electrophoresis in their laboratory in the future.
Collapse
Affiliation(s)
- Tjorben Nils Posch
- Forschungszentrum Jülich GmbH, Central Institute for Engineering, Electronics and Analytics, Analytics ZEA-3, 52425, Jülich, Germany
| | | | | | | |
Collapse
|
4
|
Moser AC, Willicott CW, Hage DS. Clinical applications of capillary electrophoresis based immunoassays. Electrophoresis 2014; 35:937-55. [PMID: 24132682 PMCID: PMC3975666 DOI: 10.1002/elps.201300421] [Citation(s) in RCA: 21] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2013] [Revised: 09/27/2013] [Accepted: 10/03/2013] [Indexed: 12/17/2022]
Abstract
Immunoassays have long been an important set of tools in clinical laboratories for the detection, diagnosis, and treatment of disease. Over the last two decades, there has been growing interest in utilizing CE as a means for conducting immunoassays with clinical samples. The resulting method is known as a CE immunoassay. This approach makes use of the selective and strong binding of antibodies for their targets, as is employed in a traditional immunoassay, and combines this with the speed, efficiency, and small sample requirements of CE. This review discusses the variety of ways in which CE immunoassays have been employed with clinical samples. An overview of the formats and detection modes that have been employed in these applications is first presented. A more detailed discussion is then given on the type of clinical targets and samples that have been measured or studied by using CE immunoassays. Particular attention is given to the use of this method in the fields of endocrinology, pharmaceutical measurements, protein and peptide analysis, immunology, infectious disease detection, and oncology. Representative applications in each of these areas are described, with these examples involving work with both traditional and microanalytical CE systems.
Collapse
Affiliation(s)
| | | | - David S. Hage
- Chemistry Department, University of Nebraska, Lincoln, NE
| |
Collapse
|
5
|
Shishehbore MR, Sheibani A, Mirparizi E. A new kinetic spectrophotometric method for the determination of major metabolite of heroin in biological samples. CHINESE CHEM LETT 2012. [DOI: 10.1016/j.cclet.2012.03.024] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/25/2022]
|
6
|
Capillary electrophoresis for the analysis of drugs of abuse in biological specimens of forensic interest. Trends Analyt Chem 2012. [DOI: 10.1016/j.trac.2011.06.019] [Citation(s) in RCA: 40] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/23/2022]
|
7
|
Szökő É, Tábi T. Analysis of biological samples by capillary electrophoresis with laser induced fluorescence detection. J Pharm Biomed Anal 2010; 53:1180-92. [DOI: 10.1016/j.jpba.2010.07.045] [Citation(s) in RCA: 47] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/20/2010] [Revised: 07/23/2010] [Accepted: 07/27/2010] [Indexed: 12/26/2022]
|
8
|
|
9
|
Lombardo-Agüí M, Cruces-Blanco C, García-Campaña A. Capillary zone electrophoresis with diode-array detection for analysis of local anaesthetics and opium alkaloids in urine samples. J Chromatogr B Analyt Technol Biomed Life Sci 2009; 877:833-6. [DOI: 10.1016/j.jchromb.2009.01.041] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2008] [Revised: 10/30/2008] [Accepted: 01/30/2009] [Indexed: 11/27/2022]
|
10
|
Zhang Z, Yan B, Liu K, Liao Y, Liu H. CE-MS analysis of heroin and its basic impurities using a charged polymer-protected gold nanoparticle-coated capillary. Electrophoresis 2009; 30:379-87. [DOI: 10.1002/elps.200800069] [Citation(s) in RCA: 46] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
|
11
|
Pantůčková P, Gebauer P, Boček P, Křivánková L. Electrolyte systems for on-line CE-MS: Detection requirements and separation possibilities. Electrophoresis 2009; 30:203-14. [DOI: 10.1002/elps.200800262] [Citation(s) in RCA: 53] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
12
|
Moser AC, Hage DS. Capillary electrophoresis-based immunoassays: principles and quantitative applications. Electrophoresis 2008; 29:3279-95. [PMID: 18646279 DOI: 10.1002/elps.200700871] [Citation(s) in RCA: 49] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/12/2022]
Abstract
The use of CE as a tool to conduct immunoassays has been an area of increasing interest over the last decade. This approach combines the efficiency, small sample requirements, and relatively high speed of CE with the selectivity of antibodies as binding agents. This review examines the various assay formats and detection modes that have been reported for these assays, along with some representative applications. Most CE immunoassays in the past have employed homogeneous methods in which the sample and reagents are allowed to react in solution. These homogeneous methods have been conducted as both competitive binding immunoassays and as noncompetitive binding immunoassays. Fluorescent labels are most commonly used for detection in these assays, but enzyme labels have also been utilized for such work. Some additional work has been performed in CE immunoassays with heterogeneous methods in which either antibodies or an analog of the analyte is immobilized to a solid support. These heterogeneous methods can be used for the selective isolation of analytes prior to their separation by CE or to remove a given species from a sample/reagent mixture prior to analysis by CE. These CE immunoassays can be used with a variety of detection modes, such as fluorescence, UV/Vis absorbance, chemiluminescence, electrochemical measurements, MS, and surface plasmon resonance.
Collapse
Affiliation(s)
- Annette C Moser
- Chemistry Department, University of Nebraska, Kearney, NE, USA
| | | |
Collapse
|
13
|
Zhang Z, Yan B, Liu K, Bo T, Liao Y, Liu H. Fragmentation pathways of heroin-related alkaloids revealed by ion trap and quadrupole time-of-flight tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2008; 22:2851-62. [PMID: 18712703 DOI: 10.1002/rcm.3686] [Citation(s) in RCA: 20] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
The electrospray ionization (ESI) ion trap and quadrupole time-of-flight (QqToF) mass spectra of heroin and seven related alkaloids, i.e., morphine, codeine, O-6-monoacetylmorphine (6-MAM), thebaine, acetylcodeine, papaverine and narcotine, have been extensively investigated in this work. The ESI mass spectrometric fragmentation pathways of protonated 6-MAM, heroin, acetylcodeine, and thebaine were comprehensively elucidated for the first time with the aid of high-resolution mass spectrometry. It was found that cleavage of the piperidine ring was the featured fragmentation route of six of the compounds, although not of papaverine and narcotine. In addition, a simple high-performance liquid chromatography (HPLC)-based separation method gave baseline resolution of all eight components. This study could play an important role in the screening for these alkaloids in different matrices by HPLC coupled to tandem mass spectrometry (MS/MS).
Collapse
Affiliation(s)
- Zhengxiang Zhang
- Beijing National Laboratory for Molecular Sciences, Ministry of Education, Institute of Analytical Chemistry, College of Chemistry and Molecular Engineering, Peking University, Beijing, P.R. China
| | | | | | | | | | | |
Collapse
|
14
|
Lin YH, Chiang JF, Lee MR, Lee RJ, Ko WK, Wu SM. Cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography for analysis of morphine and its four metabolites in human urine. Electrophoresis 2008; 29:2340-7. [DOI: 10.1002/elps.200700825] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/10/2022]
|
15
|
Lu M, Zhang L, Feng Q, Xia S, Chi Y, Tong P, Chen G. Pressure-assisted capillary electrochromatography with electrospray ionization-mass spectrometry based on silica-based monolithic column for rapid analysis of narcotics. Electrophoresis 2008; 29:936-43. [DOI: 10.1002/elps.200700653] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
|
16
|
Gottardo R, Bortolotti F, De Paoli G, Pascali JP, Miksík I, Tagliaro F. Hair analysis for illicit drugs by using capillary zone electrophoresis-electrospray ionization-ion trap mass spectrometry. J Chromatogr A 2007; 1159:185-9. [PMID: 17240388 DOI: 10.1016/j.chroma.2007.01.011] [Citation(s) in RCA: 58] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/01/2006] [Revised: 11/13/2006] [Accepted: 01/05/2007] [Indexed: 10/23/2022]
Abstract
In forensic toxicology, hair analysis has become a well established analytical strategy to investigate retrospectively drug abuse histories. In this field, gas chromatography-mass spectrometry and high-performance liquid chromatography-mass spectrometry are currently used, often after preliminary screening with immunoassays. However, on the basis of previous applications to pharmaceutical analysis, capillary zone electrophoresis coupled to ion trap mass spectrometry looks also highly promising. The purpose of the present work was the development of a simple and rapid CZE-MS method for sensitive and quantitative determination of the main drugs of abuse and their metabolites (namely, 6-monoacetylmorphine, morphine, amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethampthetamine (MDMA), benzoylecgonine, ephedrine and cocaine) in human hair. Hair samples (100 mg) were washed, cut and incubated overnight in 0.1 M HCl at 45 degrees C, then neutralized with NaOH and extracted by a liquid-liquid extraction method. CZE separations were carried out in a 100 cm x 75 microm (I.D.) uncoated fused silica capillary. The separation buffer was composed of 25 mM ammonium formate, pH 9.5; the separation voltage was 15 kV. Electrokinetic injections were performed at 7 kV for 30 s under field amplified sample stacking conditions. ESI-ion trap MS detection was performed in the ESI positive ionization mode using the following conditions: capillary voltage 4 kV, nebulizer gas (nitrogen) pressure 3psi, source temperature 150 degrees C and drying gas (nitrogen) flow rate 8l/min. A sheath liquid, composed of isopropanol-water (50:50, v/v) with 0.5% formic acid, was delivered at a flow rate of 4 microl/min. The ion trap MS operated in a selected ion monitoring mode (SIM) of positive molecular ions for each drug/metabolite. Collision induced fragmentation was also possible. Nalorphine was used as internal standard. Under the described conditions, the separation of all compounds, except amphetamine/methamphetamine, MDA/MDMA and morphine/6-MAM was achieved in 20 min, with limits of detection lower than the most severe cut-offs adopted in hair analysis (i.e. 0.1 ng/mg). Linearity was assessed within drug concentration ranges from 0.025 to 5 ng of each analyte/mg of hair. Analytical precision was fairly acceptable with RSD's < or = 3.06% for migration times and < or = 22.47% for areas in real samples, in both intra-day and day-to-day experiments. On these grounds, the described method can be proposed for rapid, selective and accurate toxicological hair analysis for both clinical and forensic purposes.
Collapse
Affiliation(s)
- Rossella Gottardo
- Department of Medicine and Public Health, Unit of Forensic Medicine, University of Verona, Verona, Italy
| | | | | | | | | | | |
Collapse
|
17
|
Lu M, Tong P, Xiao H, Xia S, Zheng X, Liu W, Zhang L, Chen G. A new method for screening and determination of diuretics by on-line CE-ESI-MS. Electrophoresis 2007; 28:1461-71. [PMID: 17367107 DOI: 10.1002/elps.200600543] [Citation(s) in RCA: 24] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/05/2022]
Abstract
A rapid, high-resolution and effective new method for analyzing 12 diuretics by CE-ESI-MS was established in this paper. Ten diuretics (except two neutral compounds) could be fast separated by CE with a DAD at 214 nm with a 20 kV voltage within 6 min, using a 50 microm id and 48.5 cm effective length uncoated fused-silica capillary in a 40 mM ammonium formate buffer (pH 9.40). CE was coupled to the mass spectrometer applying an orthogonal electrospray interface with a triple-tube sheath liquid arrangement. The sheath liquid was composed of isopropanol-water (1:1 v/v) containing 30 mM acetic acid with a flow rate of 4 microL/min. Mass spectrum was employed in the positive mode and both full scan mode and SIM scan mode were utilized. All 12 diuretics could be detected and confirmed by MS in a single analysis. Under optimized conditions, LODs for the 12 diuretics were in the range of 0.13-2.7 micromol/L at an S/N of 3, and the correlation coefficients R(2 )were between 0.9921 and 0.9978. The RDSs (n = 5) of the method was 0.24-0.94 % for migration times and 1.6-8.8 % for peak areas. The recoveries of spiked samples of 12 diuretics were between 72.4% and 118%. The real urine samples were injected directly for analysis, with only simple filtration through a 0.22 microm membrane filter in order to remove solid particles, which may cause capillary blockage. Based on the migration times and characteristic ions, the diuretics in urine samples were detected successfully. This CE-ESI-MS method for analyzing diuretics will hopefully be applied to doping control.
Collapse
Affiliation(s)
- Minghua Lu
- Ministry of Education Key Laboratory of Analysis and Detection Technology for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian, P. R. China
| | | | | | | | | | | | | | | |
Collapse
|
18
|
Abstract
This paper reviews immunoaffinity CE procedures developed since 1998 for drug, hormone, and disease marker analyses of body fluids and tissues. Immunoaffinity CE and related techniques are described. Examples of clinical applications are included.
Collapse
Affiliation(s)
- Lotta K Amundsen
- Technical Research Centre of Finland (VTT), P.O. Box 1000, FIN-02044 VTT, Finland
| | | |
Collapse
|
19
|
Hernández-Borges J, Borges-Miquel TM, Rodríguez-Delgado MA, Cifuentes A. Sample treatments prior to capillary electrophoresis-mass spectrometry. J Chromatogr A 2006; 1153:214-26. [PMID: 17098242 DOI: 10.1016/j.chroma.2006.10.070] [Citation(s) in RCA: 39] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2006] [Revised: 10/13/2006] [Accepted: 10/30/2006] [Indexed: 10/23/2022]
Abstract
Sample preparation is a crucial part of chemical analysis and in most cases can become the bottleneck of the whole analytical process. Its adequacy is a key factor in determining the success of the analysis and, therefore, careful selection and optimization of the parameters controlling sample treatment should be carried out. This work revises the different strategies that have been developed for sample preparation prior to capillary electrophoresis-mass spectrometry (CE-MS). Namely the present work presents an exhaustive and critical revision of the different samples treatments used together with on-line CE-MS including works published from January 2000 to July 2006.
Collapse
Affiliation(s)
- Javier Hernández-Borges
- Department of Analytical Chemistry, Nutrition and Food Science, University of La Laguna, Avda. Astrofísico Fco. Sánchez s/n, 38071 La Laguna, Tenerife, Spain.
| | | | | | | |
Collapse
|
20
|
Lin YH, Li JH, Ko WK, Wu SM. Direct and sensitive analysis of methamphetamine, ketamine, morphine and codeine in human urine by cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography. J Chromatogr A 2006; 1130:281-6. [PMID: 16600267 DOI: 10.1016/j.chroma.2006.03.056] [Citation(s) in RCA: 33] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/31/2005] [Revised: 03/18/2006] [Accepted: 03/20/2006] [Indexed: 10/24/2022]
Abstract
Cation-selective exhaustive injection and sweeping micellar electrokinetic chromatography (CSEI-Sweep-MEKC) was directly used to test some abuse drugs in human urine, including morphine (M), codeine (C), ketamine (K) and methamphetamine (MA). First, phosphate buffer (50 mM, pH 2.5) containing 30% methanol was filled into uncoated fused silica capillary (40 cm, 50 microm I.D.), then high conductivity buffer (100 mM phosphate, 6.9 kPa for 99.9 s) was followed. Electrokinetic injection (10 kV, 500 s) was used to load samples and to enhance sensitivity. The stacking step and separation were performed at -20 kV and 200 nm using phosphate buffer (25 mM, pH 2.5) containing 20% methanol and 100 mM sodium dodecyl sulfate. Using CSEI-Sweep-MEKC, the analytes could be simultaneously analyzed and have a detection limit down to ppb level. It was unnecessary to have sample pretreatments. During method validation, calibration plots were linear (r>or=0.9982) over a range of 150-3,000 ng/mL for M and C, 250-5,000 n g/mL for MA, and 50-1,000 ng/mL for K. The limits of detection were 15 ng/mL for M and C, and 5 ng/mL for MA and K (S/N=3, sampling 500 s at 10 kV). Comparing with capillary zone electrophoresis, the results indicated that this stacking method could increase 6,000-fold sensitivity for analysis of MA. Our method was applied for analysis of 28 real urine samples. The results showed good coincidence with immunoassay and GC-MS. This method was feasible for application to detect trace levels of abused drugs in forensic analysis.
Collapse
Affiliation(s)
- Yi-Hui Lin
- Graduate Institute of Pharmaceutical Science, College of Pharmacy, Kaohsiung Medical University, Kaohsiung, Taiwan
| | | | | | | |
Collapse
|
21
|
Baldacci A, Thormann W. Capillary electrophoresis contributions to the hydromorphone metabolism in man. Electrophoresis 2006; 27:2444-57. [PMID: 16718649 DOI: 10.1002/elps.200500867] [Citation(s) in RCA: 11] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
CE-ESI multistage IT-MS (CE-MS(n), n < or = 4) and computer simulation of fragmentation are demonstrated to be effective tools to detect and identify phase I and phase II metabolites of hydromorphone (HMOR) in human urine. Using the same CE conditions as previously developed for the analysis of urinary oxycodone and its metabolites, HMOR and its phase I metabolites produced by N-demethylation, 6-keto-reduction and N-oxidation and phase II conjugates of HMOR and its metabolites formed with glucuronic acid, glucose, and sulfuric acid could be detected in urine samples of a patient that were collected during a pharmacotherapy episode with daily ingestion of 48 mg of HMOR chloride. The CE-MS(n) data obtained with the HMOR standard, synthesized hydromorphol and hydromorphone-N-oxide, and CYP3A4 in vitro produced norhydromorphone were employed to identify the metabolites. This approach led to the identification of previously unknown HMOR metabolites, including HMOR-3O-glucide and various N-oxides, structures for which no standard compounds or mass spectra library data were available. Furthermore, the separation of alpha- and beta-hydromorphol, the stereoisomers of 6-keto-reduced HMOR, was achieved by CE in the presence of the single isomer heptakis(2,3-diacetyl-6-sulfato)-beta-CD. The obtained data indicate that the urinary excretion of alpha-hydromorphol is larger than that of beta-hydromorphol.
Collapse
Affiliation(s)
- Andrea Baldacci
- Department of Clinical Pharmacology, University of Bern, Bern, Switzerland
| | | |
Collapse
|
22
|
Jabeen R, Payne D, Wiktorowicz J, Mohammad A, Petersen J. Capillary electrophoresis and the clinical laboratory. Electrophoresis 2006; 27:2413-38. [PMID: 16718719 DOI: 10.1002/elps.200500948] [Citation(s) in RCA: 52] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Over the past 15 years, CE as an analytical tool has shown great promise in replacing many conventional clinical laboratory methods, such as electrophoresis and HPLC. CE's appeal was that it was fast, used very small amounts of sample and reagents, was extremely versatile, and was able to separate large and small analytes, whether neutral or charged. Because of this versatility, numerous methods have been developed for analytes that are of clinical interest. Other than molecular diagnostic and forensic laboratories CE has not been able to make a major impact in the United States. In contrast, in Europe and Japan an increasing number of clinical laboratories are using CE. Now that automated multicapillary instruments are commercially available along with cost-effective test kits, CE may yet be accepted as an instrument that will be routinely used in the clinical laboratories. This review will focus on areas where CE has the potential to have the greatest impact on the clinical laboratory. These include analyses of proteins found in serum and urine, hemoglobin (A1c and variants), carbohydrate-deficient transferrin, forensic and therapeutic drug screening, and molecular diagnostics.
Collapse
Affiliation(s)
- Rukhsana Jabeen
- University of Texas Medical Branch--Pathology, Galveston, TX 77555-0551, USA
| | | | | | | | | |
Collapse
|
23
|
Campa C, Coslovi A, Flamigni A, Rossi M. Overview on advances in capillary electrophoresis-mass spectrometry of carbohydrates: A tabulated review. Electrophoresis 2006; 27:2027-50. [PMID: 16736462 DOI: 10.1002/elps.200500960] [Citation(s) in RCA: 88] [Impact Index Per Article: 4.9] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
The increasing interest for carbohydrates as holder of essential bioinformations has boosted their full characterization through analytical techniques. The intent of this review is to summarize the recent trends regarding on-line and off-line CE-MS coupling for carbohydrate analysis. A statistical survey on the articles that use derivatizing agents as well as on the analyzer and type of instrument coupling (i.e. on- or off-line) is depicted. From a general overview it can be concluded that, whereas derivatization might be useful for the detection of neutral carbohydrates improving separation selectivity with volatile buffers and increasing sensitivity of the MS detection, relatively few works with derivatized carbohydrates were found; this was noticed in particular for glycosides and saccharides carrying ionizable groups, which are normally analyzed without any chemical modification. The most applied coupling is the on-line sheath-liquid interface; for on-line applications, ESI is the sole source used, whilst the most common analyzer is the IT. MS(n) is often exploited, as fragmentation increases the achieved structural information. CE-MS turned out to be mainly used for the analysis of carbohydrates in drug development (i.e. study of oligosaccharides from pathogens, carbohydrate-based drugs and drug metabolites), in nutrition and for characterization of glycans from glycoproteins. The reader will find elucidating tables regarding these recent CE-MS applications, including the main information on the analysis conditions. Comments are meant to help the immediate focus on the usefulness of the analytical technique and predict the difficulties found during analysis and, in case, their overcoming.
Collapse
|
24
|
Qi XH, Mi JQ, Zhang XX, Chang WB. Design and preparation of novel antibody system and application for the determination of heroin metabolites in urine by capillary electrophoresis. Anal Chim Acta 2005. [DOI: 10.1016/j.aca.2005.07.030] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
25
|
Smyth WF. Recent applications of capillary electrophoresis-electrospray ionisation-mass spectrometry in drug analysis. Electrophoresis 2005; 26:1334-57. [PMID: 15761915 DOI: 10.1002/elps.200406202] [Citation(s) in RCA: 62] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
A critical review of applications for the period 2000-2004, taken from the Web of Knowledge database, of the technique capillary electrophoresis-electrospray ionisation-mass spectrometry (CE-ESI-MS) in drug analysis is presented. The review is concerned with molecules of mass less than 500 Da, chosen according to selected structural classes in which they give ESI signals primarily as [M+H](+) ions although other ions, such as [M-H](-), [M+Na](+), and [M+NH(4)](+), are also reported. These structural classes are drugs with amine-containing side chains, drugs with N-containing saturated ring structures, 1,4-benzodiazepines, other heterocyclic hypnotics, carbohydrates, sulphonylureas, anthracyclines, sulphonamides, penicillins, cephalosporins, tetracyclines, nitrocatechols, steroids, flavonoids/polyphenols, cannabinols, and miscellaneous molecules. Details are given on the fragmentations, where available, that these ionic species exhibit in-source and in ion-trap, triple quadrupole, and time of flight-mass spectrometers. The review gives a critical evaluation of these recent CE-ESI-MS analytical methods in drug analysis. Analytical information on, for example, sample concentration techniques, CE separation conditions, recoveries from biological media and limits of detection (LODs) are provided. Potential applications of CE-MS to particular drugs or drug classes are also briefly discussed in the text.
Collapse
Affiliation(s)
- W Franklin Smyth
- School of Biomedical Sciences, University of Ulster, Coleraine, Co Derry, Northern Ireland.
| |
Collapse
|
26
|
Huck CW, Stecher G, Scherz H, Bonn G. Analysis of drugs, natural and bioactive compounds containing phenolic groups by capillary electrophoresis coupled to mass spectrometry. Electrophoresis 2005; 26:1319-33. [PMID: 15776479 DOI: 10.1002/elps.200410315] [Citation(s) in RCA: 44] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/09/2022]
Abstract
This review summarizes the use of capillary electrophoresis (CE) coupled to mass spectrometry (MS) for the analysis of phenolic compounds and its latest developments. Special attention is paid to the different interfaces. The instrumental setups are discussed and demonstrated in a high number of real applications.
Collapse
Affiliation(s)
- Christian W Huck
- Institute of Analytical Chemistry and Radiochemistry, Leopold-Franzens University, Innsbruck, Austria.
| | | | | | | |
Collapse
|
27
|
Joly N, El Aneed A, Martin P, Cecchelli R, Banoub J. Structural determination of the novel fragmentation routes of morphine opiate receptor antagonists using electrospray ionization quadrupole time-of-flight tandem mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2005; 19:3119-30. [PMID: 16200660 DOI: 10.1002/rcm.2179] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/04/2023]
Abstract
Electrospray ionization quadrupole time-of-flight (ESI-QqToF) mass spectra of naltrindole hydrochloride 1, naltriben mesylate 2, and naltrexone hydrochloride 3, a common series of morphine opiate receptor antagonists, were recorded using different declustering potentials. Low-energy collision-induced dissociation (CID) MS/MS experiments established the fragmentation routes of these compounds. In addition, re-confirmation of the various established fragmentation routes was effected by conducting a series of ESI-CID-QqTof-MS/MS experiments using non-conventional quasi MS(n) (up to MS8) product ion scans, which were initiated by CID in the atmospheric pressure/vacuum interface using a higher declustering potential. Precursor ion scan analyses were also performed with a conventional quadrupole-hexapole-quadrupole tandem mass spectrometer and allowed the confirmation of the genesis of some diagnostic ions.
Collapse
Affiliation(s)
- Nicolas Joly
- Laboratoire de le Barrière Hémato-Encéphalique, E.A. 2465, Département de Chimie, Université d'Artois, Béthune, France
| | | | | | | | | |
Collapse
|
28
|
Yeung WSB, Luo GA, Wang QG, Ou JP. Capillary electrophoresis-based immunoassay. J Chromatogr B Analyt Technol Biomed Life Sci 2004; 797:217-28. [PMID: 14630151 DOI: 10.1016/s1570-0232(03)00489-6] [Citation(s) in RCA: 47] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Capillary electrophoresis-based immunoassay (CEIA) is a developing analytical technique with a number of advantages over conventional immunoassay, such as reduced sample consumption, simpler procedure, easy simultaneous determination of multiple analytes, and short analysis time. However, there are still a number of technical issues that researchers on CEIA have to solve before the assay can be more widely used. These issues include method to improve the concentration sensitivity of the assay, requirement for robust separation strategy for different analytes, and method to increase the throughput of the assay. The approaches to solve these issues are reviewed. Several studies have been devoted to develop general separation strategies for CEIA, and to enhance the sensitivity of detection. The recent development of microchip-based CEIA is encouraging and is likely to address more drawbacks of CEIA, particularly on the throughput issue.
Collapse
Affiliation(s)
- W S B Yeung
- Department of Obstetrics and Gynaecology, The University of Hong Kong, Queen Mary Hospital, Pokfulam Road, Hong Kong, PR China.
| | | | | | | |
Collapse
|
29
|
Petersen JR, Okorodudu AO, Mohammad A, Payne DA. Capillary electrophoresis and its application in the clinical laboratory. Clin Chim Acta 2003; 330:1-30. [PMID: 12636924 DOI: 10.1016/s0009-8981(03)00006-8] [Citation(s) in RCA: 72] [Impact Index Per Article: 3.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
Abstract
Over the past 10 years, capillary electrophoresis (CE) is an analytical tool that has shown great promise in replacing many conventional clinical laboratory methods, especially electrophoresis and high performance liquid chromatography (HPLC). The main attraction of CE was that it was fast, used small amounts of sample and reagents, and was extremely versatile, being able to separate large and small analytes, both neutral and charged. Because of this versatility, numerous methods for clinically relevant analytes have been developed. However, with the exception of the molecular diagnostic and forensic laboratories CE has not had a major impact. A possible reason is that CE is still perceived as requiring above-average technical expertise, precluding its use in a laboratory workforce that is less technically adept. With the introduction of multicapillary instruments that are more automated, less technique-dependent, in addition to the availability of commercial and cost effective test kit methods, CE may yet be accepted as a instrument routinely used in the clinical laboratories. Thus, this review will focus on the areas where CE shows the most potential to have the greatest impact on the clinical laboratory. These include analysis of proteins found in serum, urine, CSF and body fluids, immunosubstraction electrophoresis, hemoglobin variants, lipoproteins, carbohydrate-deficient transferrin (CDT), forensic and therapeutic drug screening, and molecular diagnostics.
Collapse
Affiliation(s)
- John R Petersen
- Department of Pathology, University of Texas Medical Branch, Galveston, USA.
| | | | | | | |
Collapse
|
30
|
Garrido JMPJ, Delerue-Matos C, Borges F, Macedo TRA, Oliveira-Brett AM. Electrochemical Determination of Dihydrocodeine in Pharmaceuticals. ANAL LETT 2003. [DOI: 10.1081/al-120018246] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/03/2022]
|
31
|
Abstract
This review focuses on biological and biomedical mass spectrometry, and covers a selection of publications in this area included in the MEDLINE database for the period 1987-2001. Over the last 15 years, biological and biomedical mass spectrometry has progressed out of all recognition. The development of soft ionization methods, such as electrospray ionization and matrix-assisted laser desorption ionization, has mainly contributed to the remarkable progress, because they can easily produce gas-phase ions of large, polar, and thermally labile biomolecules, such as proteins, peptides, nucleic acids and others. The innovations of ionization methods have led to remarkable progress in mass spectrometric technology and in biochemistry, biotechnology and molecular biology research. In addition, mass spectrometry is one of the powerful and effective technologies for drug discovery and development. It is applicable to studies on structural determination, drug metabolism, including pharmacokinetics and toxicokinetics, and de novo drug discovery by applying post-genomic approarches. In the present review, the innovative soft ionization methods are first discussed along with their features. Also, the characteristics of the mass spectrometers which are active in the biological and biomedical research fields are also described. In addition, examples of the applications of biological and biomedical mass spectrometry are provided.
Collapse
Affiliation(s)
- Nariyasu Mano
- Graduate School of Pharmaceutical Sciences, Tohoku University, Aobayama, Sendai 980-8578, Japan.
| | | |
Collapse
|
32
|
Wey AB, Thormann W. Capillary electrophoresis and capillary electrophoresis-ion trap multiple-stage mass spectrometry for the differentiation and identification of oxycodone and its major metabolites in human urine. J Chromatogr B Analyt Technol Biomed Life Sci 2002; 770:191-205. [PMID: 12013227 DOI: 10.1016/s1570-0232(01)00568-2] [Citation(s) in RCA: 27] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Oxycodone (OCOD) and its metabolites, including oxymorphone (OMOR), noroxycodone (NOCOD) and noroxymorphone (NOMOR), are opioids that carry an OH group at position 14. Using capillary electrophoresis (CE) with a binary phosphate buffer containing 60% ethylene glycol (pH 7.9), the migration order of OCOD and OMOR with respect to their N-demethylated analogs was found to be reversed compared to that observed for codeine, dihydrocodeine, morphine and dihydromorphine, compounds that do not have an OH group at position 14. OCOD and structurally related compounds can also be distinguished from these opioids by their absorbance spectra at low wavelengths and via a characteristic neutral H2O loss at the MS2 level. Using the binary phosphate buffer, CE with UV detection is shown to be capable of monitoring OCOD, NOCOD, OMOR (after hydrolysis only) and NOMOR (after hydrolysis and in patient urine only) in alkaline liquid-liquid extracts of urines that were collected after ingestion of 10 mg OCOD hydrochloride and in a patient urine collected at steady state (80 mg OCOD hydrochloride daily). Using an aqueous pH 9 ammonium acetate buffer, these results were confirmed by CE-MS3. Based on CE-MS, MS2 and MS3 data, the absorbance spectra measured across the CE peaks and the relative position within the electropherogram, two peaks monitored in the UV absorbance electropherograms could be assigned to the two keto-reduced metabolites 6oxycodol (60COL) and nor6oxycodol, for which no standards were available. Comparison of data obtained with urines pretreated with two different enzyme products (beta-glucuronidase and beta-glucuronidase/arylsulfatase) suggest that OCOD, NOCOD and 6OCOL are mainly glucuronidated, whereas OMOR mainly forms other conjugates. Furthermore, in a first attempt to directly measure conjugates of the compounds of interest, solid-phase extracts were analyzed by CE-MS4, which revealed the presence of the acyl glucuronides of 6OCOL and OMOR and an unidentified OMOR conjugate. The quantitation of free OCOD and NOCOD by CE-MS using deuterated internal standards is also discussed briefly.
Collapse
Affiliation(s)
- Anita B Wey
- Department of Clinical Pharmacology, University of Bern, Switzerland
| | | |
Collapse
|
33
|
Thormann W, Lurie IS, McCord B, Marti U, Cenni B, Malik N. Advances ofcapillary electrophoresis in clinical and forensic analysis (1999-2000). Electrophoresis 2001; 22:4216-43. [PMID: 11824639 DOI: 10.1002/1522-2683(200111)22:19<4216::aid-elps4216>3.0.co;2-w] [Citation(s) in RCA: 72] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
In this paper, capillary electrophoresis in clinical and forensic analysis is reviewed on the basis of the literature of 1999, 2000 and the first papers in 2001. An overview of progress relevant examples for each major field of application, namely (i) analysis of drug seizures, explosives residues, gunshot residues and inks, (ii) monitoring of drugs, endogenous small molecules and ions in biofluids and tissues, (iii) general screening for serum proteins and analysis of specific proteins (carbohydrate deficient transferrin, alpha1-antitrypsin, lipoproteins and hemoglobins) in biological fluids, and (iv) analysis of nucleic acids and oligonucleotides in biological samples, including oligonucleotide therapeutics, are presented.
Collapse
Affiliation(s)
- W Thormann
- Department of Clinical Pharmacology, University of Bern, Switzerland.
| | | | | | | | | | | |
Collapse
|
34
|
Páez X, Hernández L. Biomedical applications of capillary electrophoresis with laser-induced fluorescence detection. Biopharm Drug Dispos 2001; 22:273-89. [PMID: 11835251 DOI: 10.1002/bdd.277] [Citation(s) in RCA: 42] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
Abstract
Capillary electrophoresis (CE) is a high-efficiency analytical technique that has had a great impact as a tool in biomedical research, clinical and forensic practice in the last ten years. Only in one of the applications, the DNA analysis, it has had an explosive exponential growth in the last few years. This impact is expressed in an enormous amount of CE articles and many reviews. The CE advantages with respect to other analytical techniques: the required very small sample volume, rapid analysis, great resolution power and low costs, have made this technique ideal for the analysis of a numerous endogenous and exogenous substances present in biological fluids. The different modes of CE have been coupled to different detection techniques such as UV-absorbance, electrochemical, mass spectrometry and laser-induced fluorescence detection (LIFD) to detect different nature and molecular size separated analytes. This review focuses mostly on the applications of CE-LIFD, to measure drugs and endogenous neuroactive substances such as amino acids and monoamines, especially in microdialysis samples from experimental animals and humans. CE-LIFD trends are discussed: automated faster analysis with capillary array systems, resolution power improvement, higher detection sensitivity, and CE systems miniaturization for extremely small sample volume, in order to make CE easier and affordable to the lab bench or the clinical bed.
Collapse
Affiliation(s)
- X Páez
- Laboratory of Behavioral Physiology, Universidad de los Andes, Mérida, Venezuela.
| | | |
Collapse
|
35
|
Wey AB, Thormann W. Head-column field-amplified sample stacking in presence of siphoning. Application to capillary electrophoresis-electrospray ionization mass spectrometry of opioids in urine. J Chromatogr A 2001; 924:507-18. [PMID: 11521903 DOI: 10.1016/s0021-9673(01)00986-4] [Citation(s) in RCA: 45] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022]
Abstract
Capillary electrophoresis (CE) with head-column field-amplified sample stacking (FASS) in presence of a water plug inserted at the capillary tip is a robust approach providing a more than 1000-fold sensitivity enhancement when applied to low-conductivity samples that are analyzed in an integrated instrument. Employing modular systems comprising a small hydrodynamic buffer flow (siphoning) towards the capillary end and featuring UV absorption or electrospray ionization mass spectrometric (MS) detection, insertion of a water plug is demonstrated to deteriorate the performance of head-column FASS or making it unfunctional. Electroinjection in the absence of the water plug can be employed instead and is shown to provide a ng/ml sensitivity when applied to low conductivity samples. With some suction of sample into the capillary during electroinjection, contamination of the sample vial with buffer is thereby largely avoided. Electroinjection applied to the CE-ion trap MS-MS and MS-MS-MS analysis of twofold diluted urines, urinary solid-phase extracts and urinary liquid-liquid extracts is shown to provide much improved sensitivity compared to hydrodynamic injection of these samples. With electroinjection from diluted urine and urinary solid-phase extracts, the presence of free opioids and their glucuronic acid conjugates can be unambiguously confirmed in urines that were collected after single-dose administration of small amounts of opioids (tested with about 7 mg codeine and 25 mg dihydrocodeine, respectively). Thus, CE-multiple MS with direct electroinjection of opioids from untreated urines could prove to become a rapid and simple approach for unambiguous urinary testing of drug abuse. Procedures leading to the reduction of siphoning in modular CE setups are briefly discussed as well.
Collapse
Affiliation(s)
- A B Wey
- Department of Clinical Pharmacology, University of Berne, Switzerland
| | | |
Collapse
|
36
|
Wey AB, Thormann W. Capillary electrophoresis-electrospray ionization ion trap mass spectrometry for analysis and confirmation testing of morphine and related compounds in urine. J Chromatogr A 2001; 916:225-38. [PMID: 11382295 DOI: 10.1016/s0021-9673(00)01096-7] [Citation(s) in RCA: 61] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
Using an aqueous background electrolyte containing 25 mM ammonium acetate and NH3 (pH 9), CE-tandem MS and CE-triple MS with atmospheric pressure electrospray ionization in the positive ion mode are shown to represent attractive approaches for analysis and confirmation testing of morphine (MOR) and related opioids in human urine. Injection of plain or diluted urine permits monitoring of solutes at concentrations above 2-5 microg/ml. For the recognition of lower concentrations, solute extraction and concentration is required. Liquid-liquid extraction at alkaline pH is shown to be suitable for analysis of free opioids only whereas solid-phase extraction using a mixed-mode polymer phase is demonstrated to permit analysis of both free and glucuronidated opioids. The former sample preparation approach, however, requires about half of the time only. Commencing with 2 ml of urine, reconstitution to provide a sample volume of 0.2 ml and hydrodynamic sample injection, detection limits for free opioids are shown to be on the 100-200 ng/ml drug level. Much improved (ppb) sensitivity is obtained by infusing the extract directly into the source of the MS system. However, solutes that produce equal fragments (such as the two glucuronides of MOR) can thereby not be distinguished. CE-tandem MS and CE-triple MS are demonstrated to be suitable to confirm the presence of MOR, MOR-3-glucuronide, 6-monoacetylmorphine, codeine, codeine-6-glucuronide, dihydrocodeine, methadone and 2-ethylidene-1,5-dimethyl-3,3-diphenylpyrrolidine in a toxicological quality control urine. The same is shown for selected metabolites of codeine and dihydrocodeine in urines collected after administration of pharmaceutical preparations.
Collapse
Affiliation(s)
- A B Wey
- Department of Clinical Pharmacology, University of Berne, Switzerland
| | | |
Collapse
|
37
|
Current awareness in phytochemical analysis. PHYTOCHEMICAL ANALYSIS : PCA 2001; 12:144-151. [PMID: 11708302 DOI: 10.1002/pca.554] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
|
38
|
Current literature in mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2001; 36:225-235. [PMID: 11345053 DOI: 10.1002/jms.89] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/23/2023]
|