1
|
Increasing temperature accelerates Ti-6Al-4V oxide degradation and selective dissolution: An Arrhenius-based analysis. Acta Biomater 2024; 178:352-365. [PMID: 38417644 DOI: 10.1016/j.actbio.2024.02.028] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/07/2023] [Revised: 02/08/2024] [Accepted: 02/19/2024] [Indexed: 03/01/2024]
Abstract
Ti-6Al-4V selective dissolution occurs in vivo on orthopedic implants as the leading edge of a pitting corrosion attack. A gap persists in our fundamental understanding of selective dissolution and pre-clinical tests fail to reproduce this damage. While CoCrMo clinical use decreases, Ti-6Al-4V and the crevice geometries where corrosion can occur remain ubiquitous in implant design. Additionally, most additively manufactured devices cleared by the FDA use Ti-6Al-4V. Accelerated preclinical testing, therefore, would aid in the evaluation of new titanium devices and biomaterials. In this study, using temperature, we (1) developed an accelerated pre-clinical methodology to rapidly induce dissolution and (2) investigated the structure-property relationship between the dissolving surface and the oxide layer. We hypothesized that solution temperature and H2O2 concentration would accelerate oxide degradation, increase corrosion kinetics and decrease experimental times. To assess this effect, we selected temperatures above (45 °C), below (24 °C), and at (37 °C) physiological levels. Then, we acquired electrochemical impedance spectra during active β dissolution, showing significant decreases in oxide polarization resistance (Rp) both over time (p = 0.000) and as temperature increased (p = 0.000). Next, using the impedance response as a guide, we quantified the extent of selective dissolution in scanning electron micrographs. As the temperature increased, the corrosion rate increased in an Arrhenius-dependent manner. Last, we identified three surface classes as the oxide properties changed: undissolved, transition and dissolved. These results indicate a concentration and temperature dependent structure-property relationship between the solution, the protective oxide film, and the substrate alloy. Additionally, we show how supraphysiological temperatures induce structurally similar dissolution to tests run at 37 °C in less experimental time. STATEMENT OF SIGNIFICANCE: Within modular taper junctions of total hip replacement systems, retrieval studies document severe corrosion including Ti-6AL-4V selective dissolution. Current pre-clinical tests and ASTM standards fail to reproduce this damage, preventing accurate screening of titanium-based biomaterials and implant designs. In this study, we induce selective dissolution using accelerated temperatures. Building off previous work, we use electrochemical impedance spectroscopy to rapidly monitor the oxide film during dissolution. We elucidate components of the dissolution mechanism, where oxide degradation precedes pit nucleation within the β phase. Using an Arrhenius approach, we relate these accelerated testing conditions to more physiologically relevant solution concentrations. In total, this study shows the importance of including adverse electrochemical events like cathodic activation and inflammatory species in pre-clinical testing.
Collapse
|
2
|
Biomedical Applications of Titanium Alloys: A Comprehensive Review. MATERIALS (BASEL, SWITZERLAND) 2023; 17:114. [PMID: 38203968 PMCID: PMC10780041 DOI: 10.3390/ma17010114] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/24/2023] [Revised: 12/15/2023] [Accepted: 12/21/2023] [Indexed: 01/12/2024]
Abstract
Titanium alloys have emerged as the most successful metallic material to ever be applied in the field of biomedical engineering. This comprehensive review covers the history of titanium in medicine, the properties of titanium and its alloys, the production technologies used to produce biomedical implants, and the most common uses for titanium and its alloys, ranging from orthopedic implants to dental prosthetics and cardiovascular devices. At the core of this success lies the combination of machinability, mechanical strength, biocompatibility, and corrosion resistance. This unique combination of useful traits has positioned titanium alloys as an indispensable material for biomedical engineering applications, enabling safer, more durable, and more efficient treatments for patients affected by various kinds of pathologies. This review takes an in-depth journey into the inherent properties that define titanium alloys and which of them are advantageous for biomedical use. It explores their production techniques and the fabrication methodologies that are utilized to machine them into their final shape. The biomedical applications of titanium alloys are then categorized and described in detail, focusing on which specific advantages titanium alloys are present when compared to other materials. This review not only captures the current state of the art, but also explores the future possibilities and limitations of titanium alloys applied in the biomedical field.
Collapse
|
3
|
Research Progress of Titanium-Based Alloys for Medical Devices. Biomedicines 2023; 11:2997. [PMID: 38001997 PMCID: PMC10669585 DOI: 10.3390/biomedicines11112997] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/25/2023] [Revised: 10/16/2023] [Accepted: 11/05/2023] [Indexed: 11/26/2023] Open
Abstract
Biomaterials are currently a unique class of materials that are essential to improving the standard of human life and extending it. In the assent of the appearance of biomaterials that contain non-toxic elements, in this study, we examine a system of Ti25Mo7Zr15TaxSi (x = 0, 0.5, 0.75, 1 wt.%) for future medical applications. The alloys were developed in a vacuum electric arc furnace and then studied from a structural, mechanical and in vivo assessment (on rabbits) perspective. The effect of the silicon addition was clearly seen in both the structural and the mechanical characteristics, standing out as beta alloys with a dendritic structure and lowering the mechanical properties as a result of the silicon addition. In experimental rabbits, the proliferation of mesenchymal stem cells was observed in the periosteum and peri-implant area, differentiating into osteoblasts and then into osteocytes. Osteoclasts were discovered within the cartilaginous islands that provide structural support to newly formed bone, playing a primary role in bone remodeling. The newly formed spongy tissue adhered to the fibrous capsule that surrounds the alloy, ensuring good osseointegration of metallic implants. The overexpression of Osteopontin, Metalloproteinase-2 (also known as gelatinase A), and Metallopeptidase-9 (also known as gelatinase B) underscores the processes of osteogenesis, bone mineralization, and normal bone remodeling.
Collapse
|
4
|
Enhanced antimicrobial properties and bioactivity of 3D-printed titanium scaffolds by multilayer bioceramic coating for large bone defects. Biomed Mater 2023; 18:065020. [PMID: 37827161 DOI: 10.1088/1748-605x/ad02d2] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/04/2023] [Accepted: 10/12/2023] [Indexed: 10/14/2023]
Abstract
The restoration of large bone defects caused by trauma, tumor resection, or infection is a major clinical problem in orthopedics and dentistry because postoperative infections, corrosion, and limited osteointegration of metal implants can lead to loosening of the implant. The aim of this study was to improve the surface properties of a 3D-printed (electron beam melting) Ti6Al4V-based macroporous scaffold by multilayer coating with bioactive silicate glasses (BAGs) and hydroxyapatite doped with a silver (AgHAP) or AgHAP additionally sonochemically modified with ZnO (ZnO-AgHAP). The coated scaffolds AgHAP_BAGs_Ti and ZnO-AgHAP_BAGs_Ti enhanced cytocompatibility in L929 and MRC5 cell lines and expressed bioactivity in simulated body fluid. A lower release of vanadium ions in coated samples compared to bare Ti scaffold indicates decreased dissolution of Ti alloy in coated samples. The coated samples reduced growth ofEscherichia coliandStaphylococcus aureusfor 4-6 orders of magnitude. Therefore, the 3D-printed Ti-based scaffolds coated with BAGs and (ZnO-)AgHAP have great potential for application as a multifunctional implant with antibacterial properties for the restoration of defects in load-bearing bones.
Collapse
|
5
|
Titanium-protein nanocomposites as new biomaterials produced by high-pressure torsion. Sci Rep 2023; 13:470. [PMID: 36627307 PMCID: PMC9832118 DOI: 10.1038/s41598-022-26716-8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/20/2022] [Accepted: 12/19/2022] [Indexed: 01/11/2023] Open
Abstract
The development of new biomaterials with outstanding mechanical properties and high biocompatibility has been a significant challenge in the last decades. Nanocrystalline metals have provided new opportunities in producing high-strength biomaterials, but the biocompatibility of these nanometals needs to be improved. In this study, we introduce metal-protein nanocomposites as high-strength biomaterials with superior biocompatibility. Small proportions of bovine serum albumin (2 and 5 vol%), an abundant protein in the mammalian body, are added to titanium, and two nanocomposites are synthesized using a severe plastic deformation process of high-pressure torsion. These new biomaterials show not only a high hardness similar to nanocrystalline pure titanium but also exhibit better biocompatibility (including cellular metabolic activity, cell cycle parameters and DNA fragmentation profile) compared to nano-titanium. These results introduce a pathway to design new biocompatible composites by employing compounds from the human body.
Collapse
|
6
|
Corrosion Behavior of Selective Laser Melting (SLM) Manufactured Ti6Al4V Alloy in Saline and BCS Solution. JOURNAL OF BIO- AND TRIBO-CORROSION 2022; 8:63. [PMID: 37736215 PMCID: PMC10512820 DOI: 10.1007/s40735-022-00657-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/11/2021] [Revised: 02/16/2022] [Accepted: 03/08/2022] [Indexed: 09/23/2023]
Abstract
The frequency of surgeries involving the use of metal implants in orthopedic medicine to replace degenerative or fractured joints is increasing, and it is therefore important to optimize the lifespan and quality of these implants. Advances in additive manufacturing (AM), or 3D printing, are creating new opportunities to personalize implants in ways that reduce mechanical stress at the joint implant interface and improve bone ingrowth and implant stability; however, it is not well understood if and to what degree the AM process alters the corrosion behavior of the materials it produces. In this study, six Ti6Al4V prints manufactured via a selective laser melting (SLM) method were examined regarding their corrosion behavior in both saline and bovine calf serum (BCS) solutions. Ecorr and Icorr values were comparable between the CM-Ti6Al4V control and SLM-EDM surfaces; however, SLM surfaces were found to have more narrow passivation behavior evidenced by significant decreases in Epass values relative to CM-Ti6Al4V. We believe this is a consequence of microstructural differences between CM-Ti6Al4V and SLM-Ti6Al4V. Specifically, the SLM-Ti6Al4V demonstrated a dominant α' martensitic microstructure and decreased vanadium-rich β-phase. BCS solution had a detrimental effect on potential parameters, Ecorr and OCP, decreasing these values relative to their saline counterparts. Increased surface roughness of the SLM-printed surface seemed to amplify the effects of the BCS solution. Furthermore, modest decreases in Epass and Ipass were observed in BCS solution, suggesting that the presence of protein may also interfere with passivation behavior. These findings have implications for how SLM-Ti6Al4V implants will perform in vivo and could possibly influence implant longevity and performance.
Collapse
|
7
|
Influence of FeCl 3 and H 2O 2 in corrosion testing of modular taper connections in total hip arthroplasty: An in vitro study. Acta Biomater 2022; 145:427-435. [PMID: 35417798 DOI: 10.1016/j.actbio.2022.04.007] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/12/2022] [Revised: 03/22/2022] [Accepted: 04/06/2022] [Indexed: 11/29/2022]
Abstract
Corrosion at the modular taper junctions in total hip arthroplasty is clinically relevant because wear particles and ions generated at this interface can lead to adverse local tissue reactions or even implant failure. In vitro tribo-corrosion tests are usually accomplished in saline solutions or calf serum (CS), but the addition of H2O2 and FeCl3 have been suggested to mimic inflammatory conditions in the joint. Inflammatory conditions may aggravate corrosive processes and, therefore, should lead in vitro to a more severe and realistic tribo-corrosive material attack. Corrosion testing at 12/14 tapers comprising a CoCrMo head taper and a Ti6Al4V trunnion was accomplished in five electrolytes (Ringer's solution (RS), RS with 30 mM H2O2 and/or 0.7 mM FeCl3 and CS) under dynamical loading for five million cycles. Resulting material loss was determined gravimetrically and by ion analysis. The tribo-corrosive material degradation was investigated by light and electron microscopy. FeCl3 enhanced the material loss from taper connections while H2O2 did not lead to a significant alteration of total material loss. In comparison to pure RS, corrosion testing in CS decreased material loss at the head taper while it increased material loss at the trunnion. The combination of FeCl3 and H2O2 led to an enhanced occurrence of micro cracks at the trunnion surface. Adding FeCl3 and optionally also H2O2 aggravates material loss in in vitro corrosion testing of taper junctions and leads to harsher and probably more realistic testing conditions. STATEMENT OF SIGNIFICANCE: Tribo-corrosive processes at taper connections in hip implants are complex and can lead to major clinical implications. Joint inflammation is assumed to aggravate taper corrosion in vivo, why FeCl3 and H2O2 have been proposed as additives to electrolytes to simulate inflammatory conditions in vitro. Often used fretting test setups, however, do not involve real taper geometries. Besides, testing is often accomplished in saline solutions or calf serum, which do not induce a clinically significant amount of corrosive material degradation. This study presents an approach to increase tribo-corrosive processes at realistic taper connections by adding FeCl3 and/or H2O2. Unlike H2O2, FeCl3 increased material loss from taper connections. The combination of both additives enhanced micro crack formation at the trunnion surfaces.
Collapse
|
8
|
Experimental and numerical study on micro-blasting process of dental implant titanium alloy: A comparison between finite element method and smoothed particle hydrodynamics. J Mech Behav Biomed Mater 2022; 132:105269. [DOI: 10.1016/j.jmbbm.2022.105269] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/17/2022] [Revised: 05/05/2022] [Accepted: 05/11/2022] [Indexed: 10/18/2022]
|
9
|
|
10
|
Machine Learning-Driven Biomaterials Evolution. ADVANCED MATERIALS (DEERFIELD BEACH, FLA.) 2022; 34:e2102703. [PMID: 34617632 DOI: 10.1002/adma.202102703] [Citation(s) in RCA: 37] [Impact Index Per Article: 18.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/09/2021] [Revised: 07/09/2021] [Indexed: 06/13/2023]
Abstract
Biomaterials is an exciting and dynamic field, which uses a collection of diverse materials to achieve desired biological responses. While there is constant evolution and innovation in materials with time, biomaterials research has been hampered by the relatively long development period required. In recent years, driven by the need to accelerate materials development, the applications of machine learning in materials science has progressed in leaps and bounds. The combination of machine learning with high-throughput theoretical predictions and high-throughput experiments (HTE) has shifted the traditional Edisonian (trial and error) paradigm to a data-driven paradigm. In this review, each type of biomaterial and their key properties and use cases are systematically discussed, followed by how machine learning can be applied in the development and design process. The discussions are classified according to various types of materials used including polymers, metals, ceramics, and nanomaterials, and implants using additive manufacturing. Last, the current gaps and potential of machine learning to further aid biomaterials discovery and application are also discussed.
Collapse
|
11
|
The influence of zirconium content on the microstructure, mechanical properties, and biocompatibility of in-situ alloying Ti-Nb-Ta based β alloys processed by selective laser melting. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2021; 131:112486. [PMID: 34857272 DOI: 10.1016/j.msec.2021.112486] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/11/2021] [Revised: 09/24/2021] [Accepted: 10/09/2021] [Indexed: 01/16/2023]
Abstract
This study investigates Ti-Nb-Ta based β alloys with different zirconium additions (0, 5, 9 wt%) manufactured by SLM. A low level of as-fabricated defects is obtained: the relative density of TNT (Z) alloys is >99.97% with the keyhole size in a range of 3-20 μm. BF TEM images combining SAD patterns of TNT(Z) alloys show single β phase obtained inside the beta matrix; BF-STEM images reveal potential nano-scale grain boundary alpha phase precipitation. Zirconium functions as a neutral element in these high β-stabilized Ti-Nb-Ta based alloys. An increase in Vickers hardness and UTS caused by zirconium additions is observed, which is explained by beta grain refinement because higher degree of undercooling occurs. Corrosion ions of TNT(Z) alloys released from immersion testing at each time intervals show extremely small concentrations (<10 μg/L). It indicated that good biocompatibility during culture with the negligible corrosion ions. High strength-to-modulus ratio β Ti alloys together with excellent biological response show their prospect for biomedical applications.
Collapse
|
12
|
Acceleration of Fracture Healing in Mouse Tibiae Using Intramedullary Nails Composed of β-Type TiNbSn Alloy with Low Young's Modulus. TOHOKU J EXP MED 2021; 255:135-142. [PMID: 34657901 DOI: 10.1620/tjem.255.135] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/18/2022]
Abstract
The optimal Young's modulus of material of orthopedic devices for fracture treatment is still unknown. The purpose of present study was to evaluate the impacts of intramedullary nails composed of a titanium alloy with low Young's modulus, on accelerating fracture healing compared with stainless steel with high Young's modulus. A β-type TiNbSn alloy with a low Young's modulus close to that of human cortical bone was developed for clinical application. TiNbSn alloy with a Young's modulus of 45 GPa and stainless steel with a Young's modulus of 205 GPa were compared, with respect to the impacts on fracture healing. Fracture and fixation using intramedullary nail were performed on the right tibiae of C57BL/6 mice. The assessment of bone healing was performed via micro-computed tomography, histomorphometry, and quantitative reverse transcription polymerase chain reaction. In micro-computed tomography, larger bone volumes were observed in the fracture callus treated with TiNbSn alloy in comparison with those treated with stainless steel. Histological assessments confirmed accelerated cartilage absorption and new bone formation in the TiNbSn alloy group compared with the stainless steel group. The expression of Col1a1, Runx2, Dkk1, and Acp5 was higher in the TiNbSn alloy group, while that of Col2a1 and Col10a1 was lower in the late phase. The present study demonstrated that the fixation by intramedullary nails with TiNbSn alloy offered an accelerated fracture healing with promotion of bone formation via increased Runx2 expression. TiNbSn alloy might be a promising material for fracture treatment devices.
Collapse
|
13
|
Microstructure, Micro-Mechanical and Tribocorrosion Behavior of Oxygen Hardened Ti-13Nb-13Zr Alloy. MATERIALS 2021; 14:ma14082088. [PMID: 33924272 PMCID: PMC8074897 DOI: 10.3390/ma14082088] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 03/11/2021] [Revised: 04/15/2021] [Accepted: 04/16/2021] [Indexed: 11/17/2022]
Abstract
In the present work, an oxygen hardening of near-β phase Ti–13Nb–13Zr alloy in plasma glow discharge at 700–1000 °C was studied. The influence of the surface treatment on the alloy microstructure, tribological and micromechanical properties, and corrosion resistance is presented. A strong influence of the treatment on the hardened zone thickness, refinement of the α’ laths and grain size of the bulk alloy were found. The outer hardened zone contained mainly an oxygen-rich Ti α’ (O) solid solution. The microhardness and elastic modulus of the hardened zone decreased with increasing hardening temperature. The hardened zone thickness, size of the α’ laths, and grain size of the bulk alloy increased with increasing treatment temperature. The wear resistance of the alloy oxygen-hardened at 1000 °C was about two hundred times, and at 700 °C, even five hundred times greater than that of the base alloy. Oxygen hardening also slightly improved the corrosion resistance. Tribocorrosion tests revealed that the alloy hardened at 700 °C was wear-resistant in a corrosive environment, and when the friction process was completed, the passive film was quickly restored. The results show that glow discharge plasma oxidation is a simple and effective method to enhance the micromechanical and tribological performance of the Ti–13Nb–13Zr alloy.
Collapse
|
14
|
The Effect of Electrophoretic Deposition Parameters on the Microstructure and Adhesion of Zein Coatings to Titanium Substrates. MATERIALS (BASEL, SWITZERLAND) 2021; 14:E312. [PMID: 33435364 PMCID: PMC7827670 DOI: 10.3390/ma14020312] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/30/2020] [Revised: 12/23/2020] [Accepted: 01/07/2021] [Indexed: 11/23/2022]
Abstract
Zein coatings were obtained by electrophoretic deposition (EPD) on commercially pure titanium substrates in an as-received state and after various chemical treatments. The properties of the zein solution, zeta potential and conductivity, at varying pH values were investigated. It was found that the zein content and the ratio of water to ethanol of the solution used for EPD, as well as the process voltage value and time, significantly influence the morphology of coatings. The deposits obtained from the solution containing 150 g/L and 200 g/L of zein and 10 vol % of water and 90 vol % of ethanol, about 4-5 μm thick, were dense and homogeneous. The effect of chemical treatment of the Ti substrate surface prior to EPD on coating adhesion to the substrate was determined. The coatings showed the highest adhesion to the as-received and anodized substrates due to the presence of a thick TiO2 layer on their surfaces and the presence of specific surface features. Coated titanium substrates showed slightly lower electrochemical corrosion resistance than the uncoated one in Ringer's solution. The coatings showed a well-developed surface topography compared to the as-received substrate, and they demonstrated hydrophilic nature. The present results provide new insights for the further development of zein-based composite coatings for biomedical engineering applications.
Collapse
|
15
|
Corrosion Behavior of As-Cast Ti–10Mo–6Zr–4Sn–3Nb and Ti–6Al–4V in Hank’s Solution: A Comparison Investigation. METALS 2020. [DOI: 10.3390/met11010011] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/17/2022]
Abstract
Newly developed Ti–10Mo–6Zr–4Sn–3Nb has fascinating mechanical properties to be used as a biomedical material. However, there is still a lack of investigation focusing on the corrosion behavior of Ti–10Mo–6Zr–4Sn–3Nb. In this work, the microstructure and corrosion behavior of as-cast Ti–10Mo–6Zr–4Sn–3Nb was investigated by optical microscopy, X-ray diffraction, and electrochemical measurements. Hank’s solution was used as the electrolyte. A classical as-cast Ti–6Al–4V was used as reference. The results showed that Ti–10Mo–6Zr–4Sn–3Nb has a higher corrosion potential and a lower corrosion current density compared with Ti–6Al–4V, indicating better corrosion resistance. However, after applying anodic potentials, Ti–10Mo–6Zr–4Sn–3Nb shows larger passivation current density in both potentiodynamic polarization and potentiostatic polarization tests. This is because more alloying elements contained in Ti–10Mo–6Zr–4Sn–3Nb trigger the production of a larger number of oxygen vacancies, resulting in a higher flux of oxygen vacancy. This finding illustrates that the passive film on Ti–10Mo–6Zr–4Sn–3Nb is less protective compared with that on Ti–6Al–4V when applying an anodic potential in their passivation range.
Collapse
|
16
|
Novel Biocompatible Zr-Based Alloy with Low Young's Modulus and Magnetic Susceptibility for Biomedical Implants. MATERIALS (BASEL, SWITZERLAND) 2020; 13:E5130. [PMID: 33202987 PMCID: PMC7696516 DOI: 10.3390/ma13225130] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 10/18/2020] [Revised: 11/10/2020] [Accepted: 11/11/2020] [Indexed: 11/25/2022]
Abstract
The microstructure, mechanical properties, magnetic susceptibility, electrochemical corrosion performance, in vitro cell compatibility and blood consistency of Zr-16Nb-xTi (x = 0, 4, 8, 12 and 16 wt.%) materials were investigated as potential materials for biomedical implants. X-ray diffraction (XRD) and Transmission electron microscopy (TEM) analyses revealed the secondary phase martensite α' formed during the quenching process. The phase composition contained metastable β and martensite α', resulting from Ti addition. These phase constitutions were the main causes of a low Young's modulus and magnetic susceptibility. The in vitro cytocompatibility analysis illustrated that the MG63 cells maintained high activity (from 91% to 97%) after culturing in Zr-16Nb-xTi extraction media for 12 days due to the high internal biocompatibility of Zr, Nb and Ti elements, as well as the optimal corrosion resistance of Zr-16Nb-xTi. On the basis of Inductively coupled plasma optical emission spectrometry (ICP-OES) ion release studies, the concentration of Zr, Nb and Ti was noted to reach the equipment detective limit of 0.001 mg/L, which was much lower than pure Ti. With respect to the corrosion behavior in Hank's solution, Zr-16Nb-16Ti displayed superior properties, possessing the lowest corrosion current density and widest passivation region, attributed to the addition of Ti. The blood compatibility test illustrated that the Zr-16Nb-xTi materials were nonhemolytic, and the platelets maintained a spherical shape, with no aggregation or activation on Zr-16Nb-xTi. Overall, Ti addition has obvious effects on the developed Zr-16Nb-xTi alloys, and Zr-16Nb-4Ti exhibited low magnetic susceptibility, low modulus, good biocompatibility and proper corrosion properties, demonstrating the potential of use as implant biomaterials.
Collapse
|
17
|
Corrosion performance of various deformed surfaces of implant steel for coronary stent applications: Effect of protein concentration. Colloids Surf B Biointerfaces 2020; 197:111407. [PMID: 33113491 DOI: 10.1016/j.colsurfb.2020.111407] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/16/2020] [Revised: 10/05/2020] [Accepted: 10/06/2020] [Indexed: 12/01/2022]
Abstract
This work was done to systematically elucidate the corrosion behavior of austenitic stainless steel subjected to various degree of cold deformation (10 %, 20 % & 30 %). The experiments were performed in phosphate buffer saline (PBS) solution having different concentrations of bovine serum albumin (0.2, 0.5, 1.0, 2.0, 4.0 g L-1). Potentiodynamic polarization tests and electrochemical impedance spectroscopy (EIS) analysis were performed to obtain the corrosion parameters. Scanning electron microscopy with energy dispersive X-ray (SEM-EDX), atomic force microscopy (AFM) and X-ray photoelectron spectroscopy (XPS) were used to determine the surface morphologies and chemical compositions of the surface films. Contact angle analysis was also used to detect the hydrophilic character of sample surfaces. The BSA had a considerable effect of inhibition on the corrosion of SSs in annealed as well as in deformed state due to its adsorption on surface of steel. For annealed samples, at 4.0 g L-1BSA concentration, the corrosion resistance was drastically decreased but interestingly not for sample with more than 10 % deformation and the concentration effect of BSA is also not very significant after 0.5 g L-1 for deformed surfaces. The breakdown potential for 30 % deformed sample is quite higher in presence of BSA even at 4.0 g L-1 while it is lowest for annealed samples in the same condition. The variation in contact angle with deformation is very less after adsorption of BSA. On the basis of the obtained results, mechanism aspect for corrosion of steel in presence of protein is also deliberated.
Collapse
|
18
|
Biological and microbiological interactions of Ti-35Nb-7Zr alloy and its basic elements on bone marrow stromal cells: good prospects for bone tissue engineering. Int J Implant Dent 2020; 6:65. [PMID: 33099690 PMCID: PMC7585585 DOI: 10.1186/s40729-020-00261-3] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/03/2020] [Accepted: 09/02/2020] [Indexed: 12/03/2022] Open
Abstract
BACKGROUND An effective biomaterial for bone replacement should have properties to avoid bacterial contamination and promote bone formation while inducing rapid cell differentiation simultaneously. Bone marrow stem cells are currently being investigated because of their known potential for differentiation in osteoblast lineage. This makes these cells a good option for stem cell-based therapy. We have aimed to analyze, in vitro, the potential of pure titanium (Ti), Ti-35Nb-7Zr alloy (A), niobium (Nb), and zirconia (Zr) to avoid the microorganisms S. aureus (S.a) and P. aeruginosa (P.a). Furthermore, our objective was to evaluate if the basic elements of Ti-35Nb-7Zr alloy have any influence on bone marrow stromal cells, the source of stem cells, and observe if these metals have properties to induce cell differentiation into osteoblasts. METHODS Bone marrow stromal cells (BMSC) were obtained from mice femurs and cultured in osteogenic media without dexamethasone as an external source of cell differentiation. The samples were divided into Ti-35Nb-7Zr alloy (A), pure titanium (Ti), Nb (niobium), and Zr (zirconia) and were characterized by scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDS). After predetermined periods, cell interaction, cytotoxicity, proliferation, and cell differentiation tests were performed. For monotypic biofilm formation, standardized suspensions (106 cells/ml) with the microorganisms S. aureus (S.a) and P. aeruginosa (P.a) were cultured for 24 h on the samples and submitted to an MTT test. RESULTS All samples presented cell proliferation, growth, and spreading. All groups presented cell viability above 70%, but the alloy (A) showed better results, with statistical differences from Nb and Zr samples. Zr expressed higher ALP activity and was statistically different from the other groups (p < 0.05). In contrast, no statistical difference was observed between the samples as regards mineralization nodules. Lower biofilm formation of S.a and P.a. was observed on the Nb samples, with statistical differences from the other samples. CONCLUSION Our results suggest that the basic elements present in the alloy have osteoinductive characteristics, and Zr has a good influence on bone marrow stromal cell differentiation. We also believe that Nb has the best potential for reducing the formation of microbial biofilms.
Collapse
|
19
|
Abstract
Dental implants are widely used in the field of oral restoration, but there are still problems leading to implant failures in clinical application, such as failed osseointegration, marginal bone resorption, and peri-implantitis, which restrict the success rate of dental implants and patient satisfaction. Poor osseointegration and bacterial infection are the most essential reasons resulting in implant failure. To improve the clinical outcomes of implants, many scholars devoted to modifying the surface of implants, especially to preparing different physical and chemical modifications to improve the osseointegration between alveolar bone and implant surface. Besides, the bioactive-coatings to promote the adhesion and colonization of ossteointegration-related proteins and cells also aim to improve the osseointegration. Meanwhile, improving the anti-bacterial performance of the implant surface can obstruct the adhesion and activity of bacteria, avoiding the occurrence of inflammation related to implants. Therefore, this review comprehensively investigates and summarizes the modifying or coating methods of implant surfaces, and analyzes the ossteointegration ability and anti-bacterial characteristics of emerging functional coatings in published references.
Collapse
|
20
|
Microstructure and Porosity Evolution of the Ti-35Zr Biomedical Alloy Produced by Elemental Powder Metallurgy. MATERIALS (BASEL, SWITZERLAND) 2020; 13:ma13204539. [PMID: 33066125 PMCID: PMC7601945 DOI: 10.3390/ma13204539] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 09/05/2020] [Revised: 10/09/2020] [Accepted: 10/10/2020] [Indexed: 06/11/2023]
Abstract
In the present study, the structure and porosity of binary Ti-35Zr (wt.%) alloy were investigated, allowing to consider powder metallurgy as a production method for new metallic materials for potential medical applications. The porous Ti-Zr alloys were obtained by milling, cold isostatic pressing and sintering. The pressure during cold isostatic pressing was a changing parameter and was respectively 250, 500, 750 and 1000 MPa. The X-ray diffraction study revealed only the α phase, which corresponds to the Ti-Zr phase diagram. The microstructure of the Ti-35Zr was observed by optical microscopy and scanning electron microscopy. These observations revealed that the volume fraction of the pores decreased from over 20% to about 7% with increasing pressure during the cold isostatic pressing. The microhardness measurements showed changes from 137 HV0.5 to 225 HV0.5.
Collapse
|
21
|
Application Solid Laser-Sintered or Machined Ti6Al4V Alloy in Manufacturing of Dental Implants and Dental Prosthetic Restorations According to Dentistry 4.0 Concept. Processes (Basel) 2020. [DOI: 10.3390/pr8060664] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022] Open
Abstract
This paper presents a comparison of the impact of milling technology in the computer numerically controlled (CNC) machining centre and selective laser sintering (SLS) and on the structure and properties of solid Ti6Al4V alloy. It has been shown that even small changes in technological conditions in the SLS manufacturing variant significantly affect changes from two to nearly two and a half times in tensile and bending strengths. Both the tensile and bending strength obtained in the most favourable manufacturing variant by the SLS method is over 25% higher than in the case of cast materials subsequently processed by milling. Plug-and-play SLS conditions provide about 60% of the possibilities. Structural, tribological and electrochemical tests were carried out. In vitro biological tests using osteoblasts confirm the good tendency for the proliferation of live cells on the substrate manufactured under the most favourable SLS conditions. The use of SLS additive technology for the manufacturing of dental implants and abutments made of Ti6Al4V alloy in combination with the digitisation of dental diagnostics and computer-aided design and manufacture of computer-aided design/manufacturing (CAD/CAM) following the idea of Dentistry 4.0 is the best choice of technology for manufacturing of prosthetic and implant devices used in dentistry.
Collapse
|
22
|
Effects of alloying elements and annealing treatment on the microstructure and mechanical properties of Nb-Ta-Ti alloys fabricated by partial diffusion for biomedical applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2020; 110:110542. [PMID: 32204053 DOI: 10.1016/j.msec.2019.110542] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2019] [Revised: 12/04/2019] [Accepted: 12/11/2019] [Indexed: 01/10/2023]
Abstract
Powder metallurgical (PM) Nb-25Ta-xTi alloys (x = 5, 15, 25, 35 at.%) were fabricated by the elemental powder sintering technology. Effects of alloying elements and annealing treatment on the microstructural evolution and mechanical properties were investigated by conducting various tests, including X-ray diffraction (XRD), scanning electron microscopy (SEM), electron probe microanalyses (EPMA), electron back scattered diffraction detector (EBSD), transmission electron microscopy (TEM) and tensile tests. The results indicated that the alloys showed a unique Nb-rich and Ta-rich dual structure due to the insufficient diffusion between powders. With the increase of Ti content, the β phase was always retained and the alloys exhibited a relatively high density in the range of 82.4% to 90.5%. Furthermore, owing to a higher diffusion coefficient of Ti and the strengthening effect of solid solution, the volume shrinkage and tensile strength both increased along with the increase of Ti content. After the annealing treatment was introduced, the microstructure became more homogeneous and fine equiaxed grains appeared, which induced a decrease in modulus and better ductility. The Nb-25Ta-25Ti alloys exhibited a good in vitro biocompatibility due to the chemical components and the introduce of surface pores. The PM Nb-Ta-Ti alloys were promising for biomedical applications in tissue engineering after evaluated both mechanical properties and in vitro biocompatibility.
Collapse
|
23
|
Tribocorrosion behaviour of pure titanium in bovine serum albumin solution: A multiscale study. J Mech Behav Biomed Mater 2019; 102:103511. [PMID: 31678736 DOI: 10.1016/j.jmbbm.2019.103511] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/18/2019] [Revised: 10/21/2019] [Accepted: 10/23/2019] [Indexed: 10/25/2022]
Abstract
Tribocorrosion behaviour of pure titanium in phosphate buffer saline (PBS) solution has been investigated systematically as a function of surface chemistry and bovine serum albumin (BSA) content in the solution. A ball-on-disk tribometer coupled with an electrochemical cell was used to study the effect of electrochemical conditions (i.e. anodic and cathodic applied potentials, as well as at open circuit potential) on the tribocorrosion response of titanium. It was found that the main material loss is due to mechanical wear caused by plastic deformation. The mechanical wear was higher under anodic conditions than under cathodic, partially due to an increased presence of debris particles at the sliding interface that act as third bodies. The effect of BSA on the interaction between alumina and titanium, as well as the behaviour of third bodies during the mechanical wear, were investigated in the nanoscale level using atomic force microscopy based force spectroscopy. It was found that the presence of BSA affects tribocorrosion in various ways. Firstly, it increases the repassivation rate of the oxide film by inhibiting the cathodic reactions and accelerating the anodic reactions. Secondly, it increases the mechanical wear by increasing the adhesion of debris onto the sliding interface, while at anodic conditions it increases the rolling efficiency of the debris particles that further enhances the mechanical wear.
Collapse
|
24
|
Review on titanium and titanium based alloys as biomaterials for orthopaedic applications. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2019; 102:844-862. [PMID: 31147056 DOI: 10.1016/j.msec.2019.04.064] [Citation(s) in RCA: 356] [Impact Index Per Article: 71.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/12/2018] [Revised: 02/20/2019] [Accepted: 04/20/2019] [Indexed: 02/07/2023]
Abstract
Variety of implant materials have been employed in various disciplines of medical science depending on the requirement of a particular application. Metals, alloys, ceramics, and polymers are the commonly used biomaterials. The main focus of this study is to review the various structural and microstructural properties of titanium and titanium based alloys used as orthopaedic implants. Orthopaedic implants need to possess certain important qualities to ensure their safe and effective use. These properties like the biocompatibility, relevant mechanical properties, high corrosion and wear resistance and osseointegration are summarized in this review. Various attempts to improve upon these properties like different processing routes, surface modifications have also been inculcated in the paper to provide an insight into the extent of research and effort that has been put into developing a highly superior titanium orthopaedic implant.
Collapse
|
25
|
Development of Cu-bearing powder metallurgy Ti alloys for biomedical applications. J Mech Behav Biomed Mater 2019; 97:41-48. [PMID: 31096149 DOI: 10.1016/j.jmbbm.2019.05.014] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/05/2018] [Revised: 05/03/2019] [Accepted: 05/08/2019] [Indexed: 11/29/2022]
Abstract
Cu-bearing Ti alloys could be used as structural biomedical materials where the releasing of Cu ions is beneficial to lower infection incidences associated with surgical implants. The manufacturing of these alloys via powder metallurgy techniques can lower the production costs. In this study three ternary Cu-bearing Ti-xAl-yCu alloys were produced using conventional powder metallurgy. The mechanical properties increase with the amount of alloying elements. Samples of each composition were also forged to clarify the effect of subjecting them to hot deformation. Forging the samples improved the strength of the alloys due to the reduction of porosity and the refinement of the microstructural features. It is found that Ti-2Al-1Cu is the most ductile, Ti-6Al-4Cu is the strongest and Ti-10Al-5Cu has a purely elastic behaviour. Some of these powder metallurgy Ti-xAl-yCu alloys have better overall mechanical behaviour than their cast counterparts and therefore are valuable alternative to produce medical and dental implants with improved properties and reduced cost.
Collapse
|
26
|
Effect of Saliva and Mucin-Based Saliva Substitutes on Fretting Processes of 316 Austenitic Stainless Steel. METALS 2019. [DOI: 10.3390/met9020178] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
The paper presents the results of research of the fretting process of 316 austenitic stainless steel in the environment of natural saliva and mucin-based saliva preparations. The aim of the work was the evaluation of synthetic saliva preparations on biomaterial wear during fretting and fretting-corrosion. The fretting process, in the oscillatory micro-movements conditions, occurs in the joints of removable dentures, especially during the chewing phase. Fretting usually leads to the intensification of fatigue damage processes of materials. Experimental research, through rheological, fretting, fretting-corrosion, and microscopic analysis were performed. Tests indicate that natural saliva and saliva preparations are similar in terms of viscoelastic properties. The statistically significant proposed saliva solutions reduced the material wear in comparison to dry sliding, which is important in the case of people with saliva secretion problem. The addition of xanthan gum to the artificial saliva composition improved rheological characteristics, but on the other hand, led to an increase of secondary wear. It was confirmed by the volumetric wear of the samples and evaluation of energy dissipated during friction. Fretting-corrosion processes were explained by a mechanism related to crevice corrosion supported by friction.
Collapse
|
27
|
Surface modification of Ti-6Al-4V alloy for osseointegration by alkaline treatment and chitosan-matrix glass-reinforced nanocomposite coating. Carbohydr Polym 2019; 205:302-311. [DOI: 10.1016/j.carbpol.2018.10.082] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 10/23/2018] [Accepted: 10/24/2018] [Indexed: 01/22/2023]
|
28
|
Determinants of corrosion resistance of Ti-6Al-4V alloy dental implants in an In Vitro model of peri-implant inflammation. PLoS One 2019; 14:e0210530. [PMID: 30703125 PMCID: PMC6354969 DOI: 10.1371/journal.pone.0210530] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/27/2018] [Accepted: 12/26/2018] [Indexed: 11/17/2022] Open
Abstract
Background Titanium (Ti) and its alloys possess high biocompatibility and corrosion resistance due to Ti ability to form a passive oxide film, i.e. TiO2, immediately after contact with oxygen. This passive layer is considered stable during function in the oral cavity, however, emerging information associate inflammatory peri-implantitis to vast increases in Ti corrosion products around diseased implants as compared to healthy ones. Thus, it is imperative to identify which factors in the peri-implant micro-environment may reduce Ti corrosion resistance. Methods The aim of this work is to simulate peri-implant inflammatory conditions in vitro to determine which factors affect corrosion susceptibility of Ti-6Al-4V dental implants. The effects of hydrogen peroxide (surrogate for reactive oxygen species, ROS, found during inflammation), albumin (a protein typical of physiological fluids), deaeration (to simulate reduced pO2 conditions during inflammation), in an acidic environment (pH 3), which is typical of inflammation condition, were investigated. Corrosion resistance of Ti-6Al-4V clinically-relevant acid etched surfaces was investigated by electrochemical techniques: Open Circuit Potential; Electrochemical Impedance Spectroscopy; and Anodic Polarization. Results Electrochemical tests confirmed that most aggressive conditions to the Ti-6Al-4V alloy were those typical of occluded cells, i.e. oxidizing conditions (H2O2), in the presence of protein and deaeration of the physiological medium. Conclusions Our results provide evidence that titanium’s corrosion resistance can be reduced by intense inflammatory conditions. This observation indicates that the micro-environment to which the implant is exposed during peri-implant inflammation is highly aggressive and may lead to TiO2 passive layer attack. Further investigation of the effect of these aggressive conditions on titanium dissolution is warranted.
Collapse
|
29
|
Role of protein adsorption in the bio corrosion of metallic implants - A review. Colloids Surf B Biointerfaces 2019; 176:494-506. [PMID: 30690385 DOI: 10.1016/j.colsurfb.2019.01.038] [Citation(s) in RCA: 58] [Impact Index Per Article: 11.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/26/2018] [Revised: 12/14/2018] [Accepted: 01/19/2019] [Indexed: 11/15/2022]
Abstract
Implants are exposed to a complex physiological environment that contains various organic compounds, especially proteins. The adsorption of proteins has an immense influence on the corrosion, biocompatibility and wear properties of implantable metals. Proteins engage in multiple processes that could potentially inhibit or promote metal degradation, depending on the type of proteins, their concentration and the properties of the implant material. In the bio corrosion process, proteins are denatured and transform into a film on the metal surface, inhibiting corrosion. This film is found on many retrieved artificial joints, especially on worn areas, and can protect the passive film from scrapping due to its lubricating effect, thus decreasing tribocorroion. On the other hand, the interactions of metal ions with proteins (and amino acids) create colloidal organometallic complexes. Transport of the complex compounds away from the interface increases dissolution rates; thus, it accelerates the corrosion of metallic implants. The influence of protein adsorption on the corrosion behaviour of metallic biomaterials is presented in this review. Biocompatible metals that are favourably used as implants such as stainless steel, Co-Cr alloys, Ti alloys and biodegradable Mg and Fe alloys are specifically addressed. We have highlighted the adsorption phenomenon of protein on metallic implants, the interaction of proteins with metallic implants and the role of protein adsorption on implant biocorrosion behaviour as well as their wear resistance.
Collapse
|
30
|
Effect of the electrochemical characteristics of titanium on the adsorption kinetics of albumin. RSC Adv 2019; 9:34265-34273. [PMID: 35529982 PMCID: PMC9073864 DOI: 10.1039/c9ra05988a] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/02/2019] [Accepted: 10/19/2019] [Indexed: 11/24/2022] Open
Abstract
An electrochemical quartz crystal microbalance (EQCM) was used to examine the electrochemical behaviour of pure titanium in phosphate buffered saline (PBS) and PBS-containing bovine serum albumin (BSA) solutions, and the associated adsorption characteristics of BSA under cathodic and anodic applied potentials. It was found that the electrochemical behaviours of bulk titanium substrate and titanium-coated QCM sensors are slightly different in PBS buffer solution, which is attributed to the difference in their surface roughness. The oxide film formed on the surface of the QCM sensor during potentiostatic tests was found to affect its electrochemical behaviour, while cathodic cleaning is not sufficient to have it removed. Lastly, the excessive amount of electrons on the titanium surface upon application of a cathodic potential could result in the desorption of BSA due to electrostatic repulsion and protein dehydration. In contrast, application of anodic potential charges the titanium surface positively and can facilitate protein adsorption when the surface is not saturated with protein. An EQCM was used to examine the electrochemical behaviour of pure titanium in PBS and PBS-containing BSA solutions, and the associated adsorption characteristics of BSA under cathodic and anodic applied potentials.![]()
Collapse
|
31
|
Corrosion behaviour of austenitic stainless steels in phosphate buffer saline solution: synergistic effects of protein concentration, time and nitrogen. NEW J CHEM 2019; 43:1943-1955. [DOI: 10.1039/c8nj04670k] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/01/2023]
Abstract
Adsorption of protein on a steel surface decreases the corrosion rate, while the formation of metal–protein complexes followed by detachment enhances the corrosion rate.
Collapse
|
32
|
Densification, microstructure evolution and fatigue behavior of Ti-13Nb-13Zr alloy processed by selective laser melting. POWDER TECHNOL 2019. [DOI: 10.1016/j.powtec.2018.09.073] [Citation(s) in RCA: 26] [Impact Index Per Article: 5.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/19/2022]
|
33
|
Biomedical Porous Shape Memory Alloys for Hard-Tissue Replacement Materials. MATERIALS (BASEL, SWITZERLAND) 2018; 11:E1716. [PMID: 30217097 PMCID: PMC6164106 DOI: 10.3390/ma11091716] [Citation(s) in RCA: 40] [Impact Index Per Article: 6.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2018] [Revised: 09/03/2018] [Accepted: 09/05/2018] [Indexed: 12/20/2022]
Abstract
Porous shape memory alloys (SMAs), including NiTi and Ni-free Ti-based alloys, are unusual materials for hard-tissue replacements because of their unique superelasticity (SE), good biocompatibility, and low elastic modulus. However, the Ni ion releasing for porous NiTi SMAs in physiological conditions and relatively low SE for porous Ni-free SMAs have delayed their clinic applications as implantable materials. The present article reviews recent research progresses on porous NiTi and Ni-free SMAs for hard-tissue replacements, focusing on two specific topics: (i) synthesis of porous SMAs with optimal porous structure, microstructure, mechanical, and biological properties; and, (ii) surface modifications that are designed to create bio-inert or bio-active surfaces with low Ni releasing and high biocompatibility for porous NiTi SMAs. With the advances of preparation technique, the porous SMAs can be tailored to satisfied porous structure with porosity ranging from 30% to 85% and different pore sizes. In addition, they can exhibit an elastic modulus of 0.4⁻15 GPa and SE of more than 2.5%, as well as good cell and tissue biocompatibility. As a result, porous SMAs had already been used in maxillofacial repairing, teeth root replacement, and cervical and lumbar vertebral implantation. Based on current research progresses, possible future directions are discussed for "property-pore structure" relationship and surface modification investigations, which could lead to optimized porous biomedical SMAs. We believe that porous SMAs with optimal porous structure and a bioactive surface layer are the most competitive candidate for short-term and long-term hard-tissue replacement materials.
Collapse
|
34
|
In vitro and in vivo biological performance of porous Ti alloys prepared by powder metallurgy. PLoS One 2018; 13:e0196169. [PMID: 29771925 PMCID: PMC5957353 DOI: 10.1371/journal.pone.0196169] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/06/2017] [Accepted: 04/06/2018] [Indexed: 11/18/2022] Open
Abstract
Titanium (Ti) and Ti-6 Aluminium-4 Vanadium alloys are the most common materials in implants composition but β type alloys are promising biomaterials because they present better mechanical properties. Besides the composition of biomaterial, many factors influence the performance of the biomaterial. For example, porous surface may modify the functional cellular response and accelerate osseointegration. This paper presents in vitro and in vivo evaluations of powder metallurgy-processed porous samples composed by different titanium alloys and pure Ti, aiming to show their potential for biomedical applications. The porous surfaces samples were produced with different designs to in vitro and in vivo tests. Samples were characterized with scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS) and elastic modulus analyses. Osteogenic cells from newborn rat calvaria were plated on discs of different materials: G1—commercially pure Ti group (CpTi); G2—Ti-6Al-4V alloy; G3—Ti-13 Niobium-13 Zirconium alloy; G4—Ti-35 Niobium alloy; G5—Ti-35 Niobium-7 Zirconium-5 Tantalum alloy. Cell adhesion and viability, total protein content, alkaline phosphatase activity, mineralization nodules and gene expression (alkaline phosphatase, Runx-2, osteocalcin and osteopontin) were assessed. After 2 and 4 weeks of implantation in rabbit tibia, bone ingrowth was analyzed using micro-computed tomography (μCT). EDS analysis confirmed the material production of each group. Metallographic and SEM analysis revealed interconnected pores, with mean pore size of 99,5μm and mean porosity of 42%, without significant difference among the groups (p>0.05). The elastic modulus values did not exhibit difference among the groups (p>0.05). Experimental alloys demonstrated better results than CpTi and Ti-6Al-4V, in gene expression and cytokines analysis, especially in early experimental periods. In conclusion, our data suggests that the experimental alloys can be used for biomedical application since they contributed to excellent cellular behavior and osseointegration besides presenting lower elastic modulus.
Collapse
|
35
|
The Role of Oral Cavity Biofilm on Metallic Biomaterial Surface Destruction-Corrosion and Friction Aspects. Int J Mol Sci 2018; 19:E743. [PMID: 29509686 PMCID: PMC5877604 DOI: 10.3390/ijms19030743] [Citation(s) in RCA: 39] [Impact Index Per Article: 6.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/31/2018] [Revised: 02/23/2018] [Accepted: 03/03/2018] [Indexed: 12/14/2022] Open
Abstract
Metallic biomaterials in the oral cavity are exposed to many factors such as saliva, bacterial microflora, food, temperature fluctuations, and mechanical forces. Extreme conditions present in the oral cavity affect biomaterial exploitation and significantly reduce its biofunctionality, limiting the time of exploitation stability. We mainly refer to friction, corrosion, and biocorrosion processes. Saliva plays an important role and is responsible for lubrication and biofilm formation as a transporter of nutrients for microorganisms. The presence of metallic elements in the oral cavity may lead to the formation of electro-galvanic cells and, as a result, may induce corrosion. Transitional microorganisms such as sulfate-reducing bacteria may also be present among the metabolic microflora in the oral cavity, which can induce biological corrosion. Microorganisms that form a biofilm locally change the conditions on the surface of biomaterials and contribute to the intensification of the biocorrosion processes. These processes may enhance allergy to metals, inflammation, or cancer development. On the other hand, the presence of saliva and biofilm may significantly reduce friction and wear on enamel as well as on biomaterials. This work summarizes data on the influence of saliva and oral biofilms on the destruction of metallic biomaterials.
Collapse
|
36
|
Effects of intramedullary nails composed of a new β-type Ti-Nb-Sn alloy with low Young's modulus on fracture healing in mouse tibiae. J Biomed Mater Res B Appl Biomater 2018; 106:2841-2848. [PMID: 29360240 DOI: 10.1002/jbm.b.34064] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/01/2016] [Revised: 09/27/2017] [Accepted: 12/02/2017] [Indexed: 11/05/2022]
Abstract
The influence of Young's moduli of materials on the fracture healing process remains unclear. This study aimed to assess the effects of intramedullary nails composed of materials with low Young's moduli on fracture repair. We previously developed a β-type Ti-Nb-Sn alloy with low Young's modulus close to that of human cortical bone. Here, we prepared two Ti-Nb-Sn alloys with Young's moduli of 45 and 78 GPa by heat treatment, and compared their effects on fracture healing. Fracture and nailing were performed in the right tibiae of C57BL/6 mice. The bone healing process was evaluated by microcomputed tomography (micro-CT), histomorphometry, and RT-PCR. We found larger bone volumes of fracture callus in the mice treated with the 45-GPa Ti-Nb-Sn alloy as compared with the 78-GPa Ti-Nb-Sn alloy in micro-CT analyses. This was confirmed with histology at day 14, with accelerated new bone formation and cartilage absorption in the 45-GPa Ti-Nb-Sn group compared with the 78-GPa Ti-Nb-Sn group. Acp5 expression was lower in the 45-GPa Ti-Nb-Sn group than in the 78-GPa Ti-Nb-Sn group at day 10. These findings indicate that intramedullary fixation with nails with a lower Young's modulus offer a greater capacity for fracture repair. Our 45-GPa Ti-Nb-Sn alloy is a promising material for fracture treatment implants. © 2018 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 106B: 2841-2848, 2018.
Collapse
|
37
|
Effect of the Heat-Treated Ti6Al4V Alloy on the Fibroblastic Cell Response. MATERIALS 2017; 11:ma11010021. [PMID: 29301205 PMCID: PMC5793519 DOI: 10.3390/ma11010021] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/23/2017] [Revised: 12/13/2017] [Accepted: 12/22/2017] [Indexed: 12/13/2022]
Abstract
Two heat treatments were carried out below (Ti6Al4V800) and above (Ti6Al4V1050) Ti6Al4V beta-phase transformation temperature (980 °C), with the purpose of studying the effect of microstructure on the adhesion and proliferation of fibroblast cells, as well as their electrochemical behavior. These alloys were seeded with 10,000 L929 fibroblast cells and immersed for 7 days in the cell culture at 37 °C, pH 7.40, 5% CO₂ and 100% relative humidity. Cell adhesion was characterized by Scanning Electron Microscopy (SEM) and Electrochemical Impedance Spectroscopy (EIS) techniques. Polygonal and elongated cell morphology was observed independent of Ti6Al4V microstructure. Besides, C, O, P, S, Na and Cl signals were detected by Energy Dispersive X-Ray Spectroscopy (EDX), associated with the synthesis of organic compounds excreted by the cells, including protein adsorption from the medium. In certain areas on Ti6Al4V and Ti6Al4V800 alloys, cells were agglomerated (island type), likely related to the globular microstructure; meanwhile, larger cellular coverage is shown for Ti6Al4V1050 alloy, forming more than one layer on the surface, where only Ca was recorded. Impedance diagrams showed a similar passive behavior for the different Ti6Al4V alloys, mainly due to TiO₂ overlaying the contribution of the organic compounds excreted by fibroblast cells.
Collapse
|
38
|
A pro-angiogenic degradable Mg-poly(lactic-co-glycolic acid) implant combined with rhbFGF in a rat limb ischemia model. Acta Biomater 2017; 64:279-289. [PMID: 28951330 DOI: 10.1016/j.actbio.2017.09.033] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/02/2017] [Revised: 09/15/2017] [Accepted: 09/22/2017] [Indexed: 12/25/2022]
Abstract
Site-specific controlled release of exogenous angiogenic growth factors, such as recombinant human basic fibroblast growth factor (rhbFGF), has become a promising approach to improve peripheral vascular disease. Here, we have developed an implant composed of spiral magnesium (Mg) and a coating made using poly(lactic-co-glycolic acid) (PLGA) with encapsulated rhbFGF (Mg-PLGA-rhbFGF). The encapsulated protein could release continually for 4weeks with well preserved bioactivity. We compared the angiogenic effect produced by Mg-PLGA-rhbFGF with that of a PLGA implant loaded with rhbFGF (PLGA-rhbFGF). The incorporation of Mg in the implant raised the microclimate pH in the polymer, which preserved the stability of rhbFGF. Mg-PLGA-rhbFGF exhibited advantages over PLGA-rhbFGF implant in terms of a cytocompatibility evaluation. An in vivo angiogenesis test further confirmed the efficacy of released rhbFGF. HE, CD31 and α-SMA staining revealed that the controlled release of rhbFGF from the Mg-PLGA-rhbFGF implant was superior in promoting angiogenesis compared with that of the PLGA-rhbFGF implant. Four weeks post-implantation, the capillary density of the Mg-PLGA-rhbFGF group was significantly higher than that of the PLGA-rhbFGF, control and the normal group (p<0.05, p<0.01 and p<0.01, respectively). Furthermore, the limb blood perfusion ratios of the Mg-PLGA-rhbFGF and PLGA-rhbFGF groups were dramatically increased, at 99.1±2.9% and 80.7±3.2%, respectively, whereas the ischemic limb did not recover in the control group. The biocompatibility of the implants was also evaluated. In conclusion, Mg-PLGA-based, sustained local delivery of rhbFGF promotes post-ischemic angiogenesis and blood flow recovery. The results suggest potential therapeutic usefulness of Mg-PLGA-rhbFGF for tissue ischemia. STATEMENT OF SIGNIFICANCE Magnesium (Mg)-based implant has been already used in patients with critical limb ischemia. Site-specific controlled release of recombinant human basic fibroblast growth factor (rhbFGF), has become a promising approach to improve peripheral vascular disease. We report here on a novel combination implant composed of spiral magnesium and a coating made using poly(lactic-co-glycolic acid) (PLGA) with encapsulated rhbFGF (Mg-PLGA-rhbFGF). The preparation method does not involve any complex processes and results in a high encapsulation efficiency (approximately 100%). The degradation of metal Mg raise the microclimate pH in the PLGA polymer, which could well preserve the bioactivity of rhbFGF incorporated in the implant. Mg-PLGA-based, sustained local delivery of rhbFGF promotes post-ischemic angiogenesis and blood flow recovery in rat limb ischemic model. This work marks the first report for controlled release of rhbFGF in combination with metal Mg, and suggests potential therapeutic usefulness of Mg-PLGA-rhbFGF for tissue ischemia.
Collapse
|
39
|
Effect of Acid Treatment on the Surface Modification of Ti-6Al-7Nb and Ti-5Al-2Nb-1Ta and Its Electrochemical Investigations in Simulated Body Fluid. ACTA ACUST UNITED AC 2017. [DOI: 10.1007/s40735-017-0096-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/26/2022]
|
40
|
Biocompatibility of Four Common Orthopedic Biomaterials Following a High-Salt Diet: An In Vivo Study. Int J Mol Sci 2017; 18:ijms18071489. [PMID: 28696371 PMCID: PMC5535979 DOI: 10.3390/ijms18071489] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/15/2017] [Revised: 07/03/2017] [Accepted: 07/08/2017] [Indexed: 01/13/2023] Open
Abstract
Nowadays, salt consumption appears to be drastically above the recommended level in industrialized countries. The health consequences of this overconsumption are heavy since high-salt intake induces cardiovascular disease, kidney dysfunction, and stroke. Moreover, harmful interaction may also occur with orthopaedic devices because overconsumption of salt reinforces the corrosive aspect of biological tissues and favors bone resorption process. In the present study, we aimed to assess the in vivo effect of three weeks of a high-salt diet, associated (or not) with two weeks of the neuro-myoelectrostimulation (NMES) rehabilitation program on the biocompatibility of four biomaterials used in the manufacture of arthroplasty implants. Thus, two non-metallic (PEEK and Al2O3) and two metallic (Ti6Al4V and CrCo) compounds were implanted in the rat tibial crest, and the implant-to-bone adhesion and cell viability of two surrounded muscles, the Flexor Digitorum (FD) and Tibialis Anterior (TA), were assessed at the end of the experiment. Results indicated lower adhesion strength for the PEEK implant compared to other biomaterials. An effect of NMES and a high-salt diet was only identified for Al2O3 and Ti6Al4V implants, respectively. Moreover, compared to a normal diet, a high-salt diet induced a higher number of dead cells on both muscles for all biomaterials, which was further increased for PEEK, Al2O3, and CrCo materials with NMES application. Finally, except for Ti6Al4V, NMES induced a higher number of dead cells in the directly stimulated muscle (FD) compared to the indirectly stimulated one (TA). This in vivo experiment highlights the potential harmful effect of a high-salt diet for people who have undergone arthroplasty, and a rehabilitation program based on NMES.
Collapse
|
41
|
Antimicrobial property, cytocompatibility and corrosion resistance of Zn-doped ZrO 2 /TiO 2 coatings on Ti6Al4V implants. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 75:7-15. [DOI: 10.1016/j.msec.2017.02.036] [Citation(s) in RCA: 82] [Impact Index Per Article: 11.7] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/07/2016] [Revised: 12/13/2016] [Accepted: 02/08/2017] [Indexed: 11/25/2022]
|
42
|
Albumin coatings by alternating current electrophoretic deposition for improving corrosion resistance and bioactivity of titanium implants. MATERIALS SCIENCE & ENGINEERING. C, MATERIALS FOR BIOLOGICAL APPLICATIONS 2017; 73:798-807. [DOI: 10.1016/j.msec.2016.12.129] [Citation(s) in RCA: 22] [Impact Index Per Article: 3.1] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/17/2016] [Revised: 11/16/2016] [Accepted: 12/21/2016] [Indexed: 11/30/2022]
|
43
|
Electrochemical comparative study on corrosion behavior of conventional and powder metallurgy titanium alloys in physiological conditions. ACTA ACUST UNITED AC 2017. [DOI: 10.1016/j.mprp.2016.04.003] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
44
|
Passivity and corrosion behaviour of Ti-10Mo-4Zr and Ti-6Al-4V alloys after long-term ageing in Ringer’s solution at 37 °C. J Solid State Electrochem 2017. [DOI: 10.1007/s10008-017-3506-6] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/29/2022]
|
45
|
The effect of phosphoric and phosphonic acid primers on bone cement bond strength to total hip stem alloys. J Mech Behav Biomed Mater 2017; 69:57-65. [PMID: 28040608 DOI: 10.1016/j.jmbbm.2016.12.011] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/27/2016] [Revised: 10/09/2016] [Accepted: 12/19/2016] [Indexed: 10/20/2022]
Abstract
Aseptic loosening at alloy-cement interfaces constitutes a main failure mechanism of cemented total hip replacements (THR). As a potential solution we investigated the effect of metal primers containing phosphoric and phosphonic acid on shear bond strength (SBS) of bone cement to THR alloys (CoCrMo, TiAlNb) and pure tin (Sn) substrates (20×8×3 mm). Metal surfaces were modified by polishing or Al2O3 blasting and primer application. Substrates without primer treatment served as references. Cylindrical cement pins (Ø 5mm) were polymerised onto substrate surfaces and aging (1, 5, 14 and 150 days) was simulated in aqueous NaCl solution (0.9%) before SBS determination and failure mode evaluation. Regardless of surface roughness and aging time, SBS for THR alloys and Sn was always significantly higher with primer treatment. Compared to untreated reference specimens (≤0.2MPa) SBS values increased even up to 350 fold (TiAlNb, 14 days) or 400 fold (CoCrMo, 5 days). In general, the phosphoric acid containing primer revealed significant higher SBS values on THR alloys compared to the phosphonic acid containing one. Al2O3 blasted specimens showed generally higher SBS values than polished ones with the exception of Sn which showed high SBS values in general. With primer treatment on polished Sn a significant reduction of SBS could not be detected even up to 150 days, whereas THR alloys showed only an SBS improvement in the short term (≤14 days). A NaCl-pitting corrosion probably led to an increasing and durable SBS on polished Sn surfaces over time. Compared to modern THR in clinical practice that shows survival rates of 10, 15, 20 or more years, the receivable bond strength enhancements described in this study appeared to be very short. The improved SBS on THR alloys lasted only a few days before it was lost again. In contrast, the phosphoric acid primer treatment of polished Sn appeared to be very promising and may play a key role in further investigations dealing with the prevention of the stem-cement debonding in THR.
Collapse
|
46
|
Differences in the expression of cell cycle genes in osteoblasts and endothelial cells cultured on the surfaces of Ti6Al4V and Ti6Al7Nb alloys. J Biomed Mater Res A 2016; 105:1607-1617. [PMID: 28002653 DOI: 10.1002/jbm.a.35972] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/23/2016] [Revised: 11/22/2016] [Accepted: 11/28/2016] [Indexed: 11/11/2022]
Abstract
Three medically used alloys (Ti6Al4V, Ti6Al7Nb, and AISI 316 L) are compared due to proliferative potential and metabolic response of human cells (osteoblasts line Saos-2 and endothelial cells line EA.hy-926) seeded on the surfaces of these alloys. Although no statistically significant difference in the proliferative potential of the cells cultured on the surfaces of examined biomaterials was observed, it does not exclude relevant differences in metabolic response of these cells assessed as changes in genes' expression. As a result of our studies it was demonstrated that the changes in the expression of examined genes were very common. Our observation suggests the presence of the process of selective recognition of the contacted biomaterials by the cells seeded on their surfaces. © 2017 Wiley Periodicals, Inc. J Biomed Mater Res Part A: 105A: 1607-1617, 2017.
Collapse
|
47
|
Evaluation of the mechanical properties of powder metallurgy Ti-6Al-7Nb alloy. J Mech Behav Biomed Mater 2016; 67:110-116. [PMID: 27988440 DOI: 10.1016/j.jmbbm.2016.12.005] [Citation(s) in RCA: 33] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/22/2016] [Revised: 11/22/2016] [Accepted: 12/08/2016] [Indexed: 12/01/2022]
Abstract
Titanium and its alloys are common biomedical materials owing to their combination of mechanical properties, corrosion resistance and biocompatibility. Powder metallurgy (PM) techniques can be used to fabricate biomaterials with tailored properties because changing the processing parameters, such as the sintering temperature, products with different level of porosity and mechanical performances can be obtained. This study addresses the production of the biomedical Ti-6Al-7Nb alloy by means of the master alloy addition variant of the PM blending elemental approach. The sintering parameters investigated guarantee that the complete diffusion of the alloying elements and the homogenization of the microstructure is achieved. The sintering of the Ti-6Al-7Nb alloy induces a total shrinkage between 7.4% and 10.7% and the level of porosity decreases from 6.2% to 4.7% with the increment of the sintering temperature. Vickers hardness (280-300 HV30) and tensile properties (different combination of strength and elongation around 900MPa and 3%) are achieved.
Collapse
|
48
|
Significant Corrosion Resistance in an Ultrafine-Grained Al6063 Alloy with a Bimodal Grain-Size Distribution through a Self-Anodic Protection Mechanism. METALS 2016. [DOI: 10.3390/met6120307] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/16/2022]
|
49
|
Corrosion behavior of plasma electrolytically oxidized gamma titanium aluminide alloy in simulated body fluid. MATERIALS CHEMISTRY AND PHYSICS 2016; 181:67-77. [PMID: 27818563 PMCID: PMC5091670 DOI: 10.1016/j.matchemphys.2016.06.034] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
Plasma electrolytic oxidized (PEO) γTiAl alloy samples were electrochemically characterized by open circuit potential (OCP), cyclic polarization and electrochemical impedance spectroscopy (EIS) to evaluate their corrosion resistance in simulated body fluid (SBF) in order to gauge their potential for biomedical applications. Experimental results through OCP and cyclic polarization studies demonstrated the protective nature and the beneficial effect of the PEO coatings on γTiAl. The PEO surface increased corrosion resistance of these surface modified alloys. EIS data indicated the presence of an underlying compact oxide layer with surface pores represented by two domes in the Nyquist plots. Electrical equivalent circuits to describe the EIS results are proposed.
Collapse
|
50
|
Mechanical and electrochemical characterisation of new Ti–Mo–Nb–Zr alloys for biomedical applications. J Mech Behav Biomed Mater 2016; 60:68-77. [DOI: 10.1016/j.jmbbm.2015.12.023] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/01/2015] [Revised: 12/15/2015] [Accepted: 12/18/2015] [Indexed: 11/22/2022]
|