Namekata N, Kobayashi N, Nomura K, Sako T, Takata N, Inoue S. Quantum optical tomography based on time-resolved and mode-selective single-photon detection by femtosecond up-conversion. Sci Rep 2023; 13:21080. [PMID: 38030670 PMCID: PMC10687223 DOI: 10.1038/s41598-023-48270-7] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/27/2023] [Accepted: 11/24/2023] [Indexed: 12/01/2023] Open
Abstract
We developed an optical time-of-flight measurement system using a time-resolved and mode-selective up-conversion single-photon detector for acquiring tomographic images of a mouse brain. The probe and pump pulses were spectrally carved from a 100-femtosecond mode-locked fiber laser at 1556 nm using 4f systems, so that their center wavelengths were situated at either side of the phase matching band separated by 30 nm. We demonstrated a sensitivity of 111 dB which is comparable to that of shot-noise-limited optical coherence tomography and an axial resolution of 57 μm (a refractive index of 1.37) with 380 femtosecond probe and pump pulses whose average powers were 1.5 mW and 30 μW, respectively. The proposed technique will open a new way of non-contact and non-invasive three-dimensional structural imaging of biological specimens with ultraweak optical irradiation.
Collapse
Affiliation(s)
- Naoto Namekata
- Institute of Quantum Science, Nihon University, 1-8-14 Kanda-Surugadai, Chiyoda-Ku, Tokyo, 101-8308, Japan.
| | - Nobuaki Kobayashi
- Department of Precision Machinery Engineering, College of Science and Technology, Nihon University, 7-24-1 Narashinodai, Funabashi, Chiba, 274-8501, Japan
| | - Kenya Nomura
- Laboratory of Physics, College of Science and Technology, Nihon University, 7-24-1 Narashinodai, Funabashi, Chiba, 274-8501, Japan
| | - Tokuei Sako
- Laboratory of Physics, College of Science and Technology, Nihon University, 7-24-1 Narashinodai, Funabashi, Chiba, 274-8501, Japan
| | - Norio Takata
- Division of Brain Science, Institute for Advanced Medical Research, Keio University School of Medicine, 35 Shinanomachi, Shinjyuku, Tokyo, 160-8582, Japan
| | - Shuichiro Inoue
- Institute of Quantum Science, Nihon University, 1-8-14 Kanda-Surugadai, Chiyoda-Ku, Tokyo, 101-8308, Japan
| |
Collapse
|
2
|
Sacino MF, Ho CY, Murnick J, Tsuchida T, Magge SN, Keating RF, Gaillard WD, Oluigbo CO. Intraoperative MRI-guided resection of focal cortical dysplasia in pediatric patients: technique and outcomes. J Neurosurg Pediatr 2016; 17:672-8. [PMID: 26919314 DOI: 10.3171/2015.10.peds15512] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECTIVE Previous meta-analysis has demonstrated that the most important factor in seizure freedom following surgery for focal cortical dysplasia (FCD) is completeness of resection. However, intraoperative detection of epileptogenic dysplastic cortical tissue remains a challenge, potentially leading to a partial resection and the need for reoperation. The objective of this study was to determine the role of intraoperative MRI (iMRI) in the intraoperative detection and localization of FCD as well as its impact on surgical decision making, completeness of resection, and seizure control outcomes. METHODS The authors retrospectively reviewed the medical records of pediatric patients who underwent iMRI-assisted resection of FCD at the Children's National Health System between January 2014 and April 2015. Data reviewed included demographics, length of surgery, details of iMRI acquisition, postoperative seizure freedom, and complications. Postsurgical seizure outcome was assessed utilizing the Engel Epilepsy Surgery Outcome Scale. RESULTS Twelve consecutive pediatric patients (8 females and 4 males) underwent iMRI-guided resection of FCD lesions. The mean age at the time of surgery was 8.8 years ± 1.6 years (range 0.7 to 18.8 years), and the mean duration of follow up was 3.5 months ± 1.0 month. The mean age at seizure onset was 2.8 years ± 1.0 year (range birth to 9.0 years). Two patients had Type 1 FCD, 5 patients had Type 2A FCD, 2 patients had Type 2B FCD, and 3 patients had FCD of undetermined classification. iMRI findings impacted intraoperative surgical decision making in 5 (42%) of the 12 patients, who then underwent further exploration of the resection cavity. At the time of the last postoperative follow-up, 11 (92%) of the 12 patients were seizure free (Engel Class I). No patients underwent reoperation following iMRI-guided surgery. CONCLUSIONS iMRI-guided resection of FCD in pediatric patients precluded the need for repeat surgery. Furthermore, it resulted in the achievement of complete resection in all the patients, leading to a high rate of postoperative seizure freedom.
Collapse
Affiliation(s)
| | | | | | - Tammy Tsuchida
- Neurology, Children's National Medical Center, Washington, DC
| | | | | | | | | |
Collapse
|
3
|
Oluigbo CO, Wang J, Whitehead MT, Magge S, Myseros JS, Yaun A, Depositario-Cabacar D, Gaillard WD, Keating R. The influence of lesion volume, perilesion resection volume, and completeness of resection on seizure outcome after resective epilepsy surgery for cortical dysplasia in children. J Neurosurg Pediatr 2015; 15:644-50. [PMID: 26030332 DOI: 10.3171/2014.10.peds14282] [Citation(s) in RCA: 37] [Impact Index Per Article: 4.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Submit a Manuscript] [Subscribe] [Scholar Register] [Indexed: 11/06/2022]
Abstract
OBJECT Focal cortical dysplasia (FCD) is one of the most common causes of intractable epilepsy leading to surgery in children. The predictors of seizure freedom after surgical management for FCD are still unclear. The objective of this study was to perform a volumetric analysis of factors shown on the preresection and postresection brain MRI scans of patients who had undergone resective epilepsy surgery for cortical dysplasia and to determine the influence of these factors on seizure outcome. METHODS The authors reviewed the medical records and brain images of 43 consecutive patients with focal MRI-documented abnormalities and a pathological diagnosis of FCD who had undergone surgical treatment for refractory epilepsy. Preoperative lesion volume and postoperative resection volume were calculated by manual segmentation using OsiriX PRO software. RESULTS Forty-three patients underwent first-time surgery for resection of an FCD. The age range of these patients at the time of surgery ranged from 2 months to 21.8 years (mean age 7.3 years). The median duration of follow-up was 20 months. The mean age at onset was 31.6 months (range 1 day to 168 months). Complete resection of the area of an FCD, as adjudged from the postoperative brain MR images, was significantly associated with seizure control (p = 0.0005). The odds of having good seizure control among those who underwent complete resection were about 6 times higher than those among the patients who did not undergo complete resection. Seizure control was not significantly associated with lesion volume (p = 0.46) or perilesion resection volume (p = 0.86). CONCLUSIONS The completeness of FCD resection in children is a significant predictor of seizure freedom. Neither lesion volume nor the further resection of perilesional tissue is predictive of seizure freedom.
Collapse
|
4
|
Mahmoud AM, Sandoval C, Teng B, Schnermann JB, Martin KH, Mustafa SJ, Mukdadi OM. High-resolution vascular tissue characterization in mice using 55MHz ultrasound hybrid imaging. ULTRASONICS 2013; 53:727-738. [PMID: 23218908 PMCID: PMC3639478 DOI: 10.1016/j.ultras.2012.10.017] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/29/2012] [Revised: 10/24/2012] [Accepted: 10/29/2012] [Indexed: 06/01/2023]
Abstract
Ultrasound and Duplex ultrasonography in particular are routinely used to diagnose cardiovascular disease (CVD), which is the leading cause of morbidity and mortality worldwide. However, these techniques may not be able to characterize vascular tissue compositional changes due to CVD. This work describes an ultrasound-based hybrid imaging technique that can be used for vascular tissue characterization and the diagnosis of atherosclerosis. Ultrasound radiofrequency (RF) data were acquired and processed in time, frequency, and wavelet domains to extract six parameters including time integrated backscatter (T(IB)), time variance (T(var)), time entropy (T(E)), frequency integrated backscatter (F(IB)), wavelet root mean square value (W(rms)), and wavelet integrated backscatter (W(IB)). Each parameter was used to reconstruct an image co-registered to morphological B-scan. The combined set of hybrid images were used to characterize vascular tissue in vitro and in vivo using three mouse models including control (C57BL/6), and atherosclerotic apolipoprotein E-knockout (APOE-KO) and APOE/A(1) adenosine receptor double knockout (DKO) mice. The technique was tested using high-frequency ultrasound including single-element (center frequency=55 MHz) and commercial array (center frequency=40 MHz) systems providing superior spatial resolutions of 24 μm and 40 μm, respectively. Atherosclerotic vascular lesions in the APOE-KO mouse exhibited the highest values (contrast) of -10.11±1.92 dB, -12.13±2.13 dB, -7.54±1.45 dB, -5.10±1.06 dB, -5.25±0.94 dB, and -10.23±2.12 dB in T(IB), T(var), T(E), F(IB), W(rms), W(IB) hybrid images (n=10, p<0.05), respectively. Control segments of normal vascular tissue showed the lowest values of -20.20±2.71 dB, -22.54±4.54 dB, -14.94±2.05 dB, -9.64±1.34 dB, -10.20±1.27 dB, and -19.36±3.24 dB in same hybrid images (n=6, p<0.05). Results from both histology and optical images showed good agreement with ultrasound findings within a maximum error of 3.6% in lesion estimation. This study demonstrated the feasibility of a high-resolution hybrid imaging technique to diagnose atherosclerosis and characterize plaque components in mouse. In the future, it can be easily implemented on commercial ultrasound systems and eventually translated into clinics as a screening tool for atherosclerosis and the assessment of vulnerable plaques.
Collapse
Affiliation(s)
- Ahmed M Mahmoud
- Center for Ultrasound Molecular Imaging and Therapeutics, Heart and Vascular Institute, University of Pittsburgh, Pittsburgh, PA 15261, United States.
| | | | | | | | | | | | | |
Collapse
|
5
|
Binding J, Ben Arous J, Léger JF, Gigan S, Boccara C, Bourdieu L. Brain refractive index measured in vivo with high-NA defocus-corrected full-field OCT and consequences for two-photon microscopy. OPTICS EXPRESS 2011; 19:4833-47. [PMID: 21445119 DOI: 10.1364/oe.19.004833] [Citation(s) in RCA: 70] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/20/2023]
Abstract
Two-photon laser scanning microscopy (2PLSM) is an important tool for in vivo tissue imaging with sub-cellular resolution, but the penetration depth of current systems is potentially limited by sample-induced optical aberrations. To quantify these, we measured the refractive index n' in the somatosensory cortex of 7 rats in vivo using defocus optimization in full-field optical coherence tomography (ff-OCT). We found n' to be independent of imaging depth or rat age. From these measurements, we calculated that two-photon imaging beyond 200 µm into the cortex is limited by spherical aberration, indicating that adaptive optics will improve imaging depth.
Collapse
Affiliation(s)
- Jonas Binding
- IBENS, UMR 8197 CNRS and INSERM, Ecole Normale Supérieure, 46, Rue d’Ulm, 75005 Paris, France.
| | | | | | | | | | | |
Collapse
|
6
|
Zhang L, Xu X, Hu C, Sun L, Yen JT, Cannata JM, Shung KK. A high-frequency, high frame rate duplex ultrasound linear array imaging system for small animal imaging. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2010; 57:1548-57. [PMID: 20639149 PMCID: PMC2908919 DOI: 10.1109/tuffc.2010.1585] [Citation(s) in RCA: 7] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
High-frequency (HF) ultrasound imaging has been shown to be useful for non-invasively imaging anatomical structures of the eye and small animals in biological and pharmaceutical research, achieving superior spatial resolution. Cardiovascular research utilizing mice requires not only realtime B-scan imaging, but also ultrasound Doppler to evaluate both anatomy and blood flow of the mouse heart. This paper reports the development of an HF ultrasound duplex imaging system capable of both B-mode imaging and Doppler flow measurements, using a 64-element linear array. The system included an HF pulsed-wave Doppler module, a 32-channel HF B-mode imaging module, a PC with a 200 MS/s 14-bit A/D card, and real-time LabView software. A 50 dB SNR and a depth of penetration of larger than 12 mm were achieved using a 35-MHz linear array with 50 μm pitch. The two-way beam widths were determined to be 165 to 260 μm and the clutter-energy-to-total-energy ratio (CTR) were 9.1 to 12 dB when the array was electronically focused at different focal points at depths from 4.8 to 9.6 mm. The system is capable of acquiring real-time B-mode images at a rate greater than 400 frames per second (fps) for a 4.8 x 13 mm field of view, using a 30- MHz 64-element linear array with 100 μm pitch. Sample in vivo cardiac high frame rate images and duplex images of mouse hearts are shown to assess its current imaging capability and performance for small animals.
Collapse
Affiliation(s)
- Lequan Zhang
- University of Southern California, Department of Biomedical Engineering, Los Angeles, CA.
| | | | | | | | | | | | | |
Collapse
|
7
|
Böhringer HJ, Lankenau E, Stellmacher F, Reusche E, Hüttmann G, Giese A. Imaging of human brain tumor tissue by near-infrared laser coherence tomography. Acta Neurochir (Wien) 2009; 151:507-17; discussion 517. [PMID: 19343270 PMCID: PMC3085760 DOI: 10.1007/s00701-009-0248-y] [Citation(s) in RCA: 80] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/18/2008] [Accepted: 02/19/2009] [Indexed: 12/22/2022]
Abstract
INTRODUCTION Intraoperative detection of residual tumor remains an important challenge in surgery to treat gliomas. New developments in optical techniques offer non-invasive high-resolution imaging that may integrate well into the workflow of neurosurgical operations. Using an intracranial glioma model, we have recently shown that time domain optical coherence tomography (OCT) allows discrimination of normal brain, diffusely invaded brain tissue, and solid tumor. OCT imaging allowed acquisition of 2D and 3D data arrays for multiplanar analysis of the tumor to brain interface. In this study we have analyzed biopsy specimens of human brain tumors and we present the first feasibility study of intraoperative OCT and post-image acquisition processing for non-invasive imaging of the brain and brain tumor. METHODS We used a Sirius 713 Tomograph with a superluminescence diode emitting light at a near infrared central wavelength of 1,310 nm and a coherence length of 15 microm. The light is passed through an optical mono mode fiber to a modified OCT adapter containing a lens system with a working distance of 10 cm and an integrated pilot laser. Navigation-registered tumor biopsies were imaged ex vivo and the intraoperative site of optical tissue analysis was registered by marker acquisition using a neuronavigation system. RESULTS Optical coherence tomography non-contact measurements of brain and brain tumor tissue produced B-scan images of 4 mm in width and 1.5-2.0 mm in depth at an axial and lateral optical resolution of 15 microm. OCT imaging demonstrated a different microstructure and characteristic signal attenuation profiles of tumor versus normal brain. Post-image acquisition processing and automated detection of the tissue to air interface was used to realign A-scans to compensate for image distortions caused by pulse- and respiration-induced movements of the target volume. Realigned images allowed monitoring of intensity changes within the scan line and facilitated selection of areas for the averaging of A-scans and the calculation of attenuation coefficients for specific regions of interest. CONCLUSION This feasibility study has demonstrated that OCT analysis of the tissue microstructure and light attenuation characteristics discriminate normal brain, areas of tumor infiltrated brain, solid tumor, and necrosis. The working distance of the OCT adapter and the A-scan acquisition rate conceptually allows integration of the OCT applicator into the optical path of the operating microscopes. This would allow a continuous analysis of the resection plain, providing optical tomography, thereby adding a third dimension to the microscopic view and information on the light attenuation characteristics of the tissue.
Collapse
Affiliation(s)
| | - E. Lankenau
- Institute for Biomedical Optics, University of Lübeck, Lübeck, Germany
| | - F. Stellmacher
- Department of Neuropathology, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - E. Reusche
- Department of Neuropathology, University Hospital Schleswig-Holstein, Lübeck, Germany
| | - G. Hüttmann
- Institute for Biomedical Optics, University of Lübeck, Lübeck, Germany
| | - A. Giese
- Department of Neurosurgery, Georg-August-University of Göttingen, Robert-Koch-Strasse 40, 37075 Göttingen, Germany
| |
Collapse
|
8
|
Nakaji H, Kouyama N, Muragaki Y, Kawakami Y, Iseki H. Localization of nerve fiber bundles by polarization-sensitive optical coherence tomography. J Neurosci Methods 2008; 174:82-90. [DOI: 10.1016/j.jneumeth.2008.07.004] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/29/2008] [Revised: 06/27/2008] [Accepted: 07/02/2008] [Indexed: 11/15/2022]
|
9
|
Sun L, Xu X, Richard WD, Feng C, Johnson JA, Shung KK. A high-frame rate duplex ultrasound biomicroscopy for small animal imaging in vivo. IEEE Trans Biomed Eng 2008; 55:2039-49. [PMID: 18632366 DOI: 10.1109/tbme.2008.919110] [Citation(s) in RCA: 41] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Abstract
Much of the current knowledge of human cardiovascular pathologies and treatment strategies has been gained from understanding the cardiac physiologies and functions in small animal models, such as mice, rats, and zebrafish. In this paper, we present the development of a high-frame-rate duplex ultrasound biomicroscopy (UBM) capable of B-mode imaging and pulsed-wave (PW) Doppler measurement for in vivo cardiovascular investigation in small animals. A frame rate of 200 frames per second (fps) was accomplished at a view of 5 mm x 8 mm, using a novel high-speed sector probe and specially designed lightweight transducers. In a reduced lateral view of 1.2 mm, a frame rate of 400 fps was achieved to examine more detailed cardiac motion. The UBM utilized transducers with different center frequencies (40-75 MHz) and geometries, which made it useful for various applications in small animal cardiac imaging. The highest spatial resolution the UBM achieved was 25 microm x 56 microm. In addition, the image-guided PW Doppler implemented in the UBM demonstrated the detection of the velocity of a moving wire as low as 0.1 mm/s, and flow in a polyimide tube as small as 200 microm in diameter. Furthermore, the UBM achieved a 15- microV minimal detectable signal and a 60-dB dynamic range using a low-cost PCB-based design. Finally, sample in vivo cardiac images of mouse and zebrafish hearts were given. These results showed that the UBM integrated with B-mode and PW Doppler is useful to investigate the pathophysiological mechanism in the cardiovascular studies.
Collapse
Affiliation(s)
- Lei Sun
- Department of Health Technology and Informatics, Hong Kong Polytechnic University, Hong Hun, Kowloon, Hong Kong SAR, China.
| | | | | | | | | | | |
Collapse
|
10
|
Sun L, Richard WD, Cannata JM, Feng CC, Johnson JA, Yen JT, Shung KK. A high-frame rate high-frequency ultrasonic system for cardiac imaging in mice. IEEE TRANSACTIONS ON ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL 2007; 54:1648-55. [PMID: 17703669 DOI: 10.1109/tuffc.2007.436] [Citation(s) in RCA: 12] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/16/2023]
Abstract
We report the development of a high-frequency (30-50 MHz), real-time ultrasonic imaging system for cardiac imaging in mice. This system is capable of producing images at 130 frames per second (fps) with a spatial resolution of less than 50 microm. A novel mechanical sector probe was developed that utilizes a magnetic drive mechanism and custom-built servo controller for high speed and accuracy. Additionally, a very light-weight (< 0.28 g), single-element transducer was constructed and used to reduce the mass load on the motor. The imaging electronics were triggered according to the angular position of the transducer in order to compensate for the varying speed of the sector motor. This strategy ensured the production of equally spaced scan lines with minimal jitter. Wire phantom testing showed that the system axial and lateral resolutions were 48 microm and 72 microm, respectively. In vivo experiments showed that high-frequency ultrasonic imaging at 130 fps is capable of showing a detailed depiction of a beating mouse heart.
Collapse
Affiliation(s)
- Lei Sun
- Department of Biomedical Engineering, University of Southern California, Los Angeles, CA 90089, USA.
| | | | | | | | | | | | | |
Collapse
|
11
|
Jafri MS, Farhang S, Tang RS, Desai N, Fishman PS, Rohwer RG, Tang CM, Schmitt JM. Optical coherence tomography in the diagnosis and treatment of neurological disorders. JOURNAL OF BIOMEDICAL OPTICS 2005; 10:051603. [PMID: 16292951 DOI: 10.1117/1.2116967] [Citation(s) in RCA: 23] [Impact Index Per Article: 1.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
Optical contrast is often the limiting factor in the imaging of live biological tissue. Studies were conducted in postmortem human brain to identify clinical applications where the structures of interest possess high intrinsic optical contrast and where the real-time, high-resolution imaging capabilities of optical coherence tomography (OCT) may be critical. Myelinated fiber tracts and blood vessels are two structures with high optical contrast. The ability to image these two structures in real time may improve the efficacy and safety of a neurosurgical procedure to treat Parkinson's disease called deep brain stimulation (DBS). OCT was evaluated as a potential optical guidance system for DBS in 25 human brains. The results suggest that catheter-based OCT has the resolution and contrast necessary for DBS targeting. The results also demonstrate the ability of OCT to detect blood vessels with high sensitivity, suggesting a possible means to avoid their laceration during DBS. Other microscopic structures in the human brain with high optical contrast are pathological vacuoles associated with transmissible spongiform encephalopathy (TSE). TSE include diseases such as Mad Cow disease and Creutzfeldt-Jakob disease (CJD) in humans. OCT performed on the brain from a woman who died of CJD was able to detect clearly the pathological vacuoles.
Collapse
Affiliation(s)
- M Samir Jafri
- Baltimore VA Medical Center, University of Maryland School of Medicine, Department of Neurology, 655 West Baltimore Street, Baltimore, Maryland 21201, USA.
| | | | | | | | | | | | | | | |
Collapse
|
12
|
Bizheva K, Unterhuber A, Hermann B, Povazay B, Sattmann H, Fercher AF, Drexler W, Preusser M, Budka H, Stingl A, Le T. Imaging ex vivo healthy and pathological human brain tissue with ultra-high-resolution optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2005; 10:11006. [PMID: 15847572 DOI: 10.1117/1.1851513] [Citation(s) in RCA: 34] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
The ability of ultra-high-resolution optical coherence tomography (UHR OCT) to discriminate between healthy and pathological human brain tissue is examined by imaging ex vivo tissue morphology of various brain biopsies. Micrometer-scale OCT resolution (0.9x2 microm, axialxlateral) is achieved in biological tissue by interfacing a state-of-the-art Ti:Al2O3 laser (lambda(c)=800 nm, delta lambda=260 nm, and P(out)=120 mW exfiber) to a free-space OCT system utilizing dynamic focusing. UHR OCT images are acquired from both healthy brain tissue and various types of brain tumors including fibrous, athypical, and transitional meningioma and ganglioglioma. A comparison of the tomograms with standard hematoxylin and eosin (H&E) stained histological sections of the imaged biopsies demonstrates the ability of UHR OCT to visualize and identify morphological features such as microcalcifications (>20 microm), enlarged nuclei of tumor cells (approximately 8 to 15 microm), small cysts, and blood vessels, which are characteristic of neuropathologies and normally absent in healthy brain tissue.
Collapse
Affiliation(s)
- Kostadinka Bizheva
- Medical University of Vienna and Christian Doppler Laboratory, Center for Biomedical Engineering and Physics, Vienna A-1090, Austria
| | | | | | | | | | | | | | | | | | | | | |
Collapse
|
13
|
Bizheva K, Unterhuber A, Hermann B, Povazay B, Sattmann H, Drexler W, Stingl A, Le T, Mei M, Holzwarth R, Reitsamer HA, Morgan JE, Cowey A. Imaging ex vivo and in vitro brain morphology in animal models with ultrahigh resolution optical coherence tomography. JOURNAL OF BIOMEDICAL OPTICS 2004; 9:719-24. [PMID: 15250758 DOI: 10.1117/1.1756920] [Citation(s) in RCA: 26] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/18/2023]
Abstract
The feasibility of ultrahigh resolution optical coherence tomography (UHR OCT) to image ex vivo and in vitro brain tissue morphology on a scale from single neuron cells to a whole animal brain was investigated using a number of animal models. Sub-2-microm axial resolution OCT in biological tissue was achieved at different central wavelengths by separately interfacing two state-of-the-art broad bandwidth light sources (titanium:sapphire, Ti:Al2O3 laser, lambdac=800 nm, Deltalambda=260 nm, Pout=50 mW and a fiber laser light source, lambdac=1350 nm, Deltalambda=470 nm, Pout=4 mW) to free-space or fiber-based OCT systems, designed for optimal performance in the appropriate wavelength regions. The ability of sub-2-microm axial resolution OCT to visualize intracellular morphology was demonstrated by imaging living ganglion cells in cultures. The feasibility of UHR OCT to image the globular structure of an entire animal brain as well as to resolve fine morphological features at various depths in it was tested by imaging a fixed honeybee brain. Possible degradation of OCT axial resolution with depth in optically dense brain tissue was examined by depositing microspheres through the blood stream to various depths in the brain of a living rabbit. It was determined that in the 1100 to 1600-nm wavelength range, OCT axial resolution was well preserved, even at depths greater than 500 microm, and permitted distinct visualization of microspheres 15 microm in diameter. In addition, the OCT image penetration depth and the scattering properties of gray and white brain matter were evaluated in tissue samples from the visual cortex of a fixed monkey brain.
Collapse
Affiliation(s)
- Kostadinka Bizheva
- Department of Medical Physics, Medical University of Vienna and Christian Doppler Laboratory, Vienna A-1090, Austria
| | | | | | | | | | | | | | | | | | | | | | | | | |
Collapse
|
14
|
Abstract
Optical coherence tomography (OCT) is an emerging imaging technology with applications in biology, medicine, and materials investigations. Attractive features include high cellular-level resolution, real-time acquisition rates, and spectroscopic feature extraction in a compact noninvasive instrument. OCT can perform "optical biopsies" of tissue, producing images approaching the resolution of histology without having to resect and histologically process tissue specimens for characterization and diagnosis. This article will review several of the current technological developments in OCT. To illustrate the potential of this technology for neuroimaging, applications for imaging neural development, the neural retina, tumors of the central nervous system, and the microsurgical repair of peripheral nerves will be presented. This technology offers a potential investigative tool for addressing many of the present challenges in neuroimaging.
Collapse
Affiliation(s)
- Stephen A Boppart
- Department of Electrical and Computer Engineering, Bioengineering Program, Beckman Institute for Advanced Science and Technology, College of Medicine, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, USA.
| |
Collapse
|
15
|
Kholodnykh AI, Petrova IY, Larin KV, Motamedi M, Esenaliev RO. Precision of measurement of tissue optical properties with optical coherence tomography. APPLIED OPTICS 2003; 42:3027-37. [PMID: 12790454 DOI: 10.1364/ao.42.003027] [Citation(s) in RCA: 42] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/19/2023]
Abstract
Accurate and noninvasive measurement of tissue optical properties can be used for biomedical diagnostics and monitoring of tissue analytes. Noninvasive measurement of tissue optical properties (total attenuation and scattering coefficients, optical thickness, etc.) can be performed with the optical coherence tomography (OCT) technique. However, speckle noise substantially deteriorates the accuracy of the measurements with this technique. We studied suppression of speckle noise for accurate measurement of backscattering signal and scattering coefficient with the OCT technique. Our results demonstrate that the precision of measurement of backscattering signals with the OCT technique can be 0.2% for homogeneously scattering media and 0.7% for skin, if spatial averaging of speckle noise is applied. This averaging allows us to achieve the precision of tissue scattering coefficient measurements of approximately +/-0.8%. This precision can be further improved by a factor of 2-3, upon optimization of OCT operating parameters.
Collapse
Affiliation(s)
- Alexander I Kholodnykh
- University of Texas Medical Branch, 301 University Boulevard, Galveston, Texas 77555-0456, USA
| | | | | | | | | |
Collapse
|
16
|
Abstract
The current status and challenges of small animal non-invasive imaging is briefly reviewed. The advantages of non-invasive studies on living animals versus post-mortem studies are evaluated. An argument is advanced that even in post-mortem situations, non-invasive imaging may play an important role in efficiently characterizing small animal phenotypes as well as pathology. Issues of data interpretation under anesthetized conditions in live animal studies are also reviewed. The five imaging technologies covered include CT, PET, ultrasound, MRI and optical imaging. The structural and physiological information content of these different modalities is reviewed along with the ability of these techniques to scale down for use in small mammals such as mice and rats. In general, it was found that most of these technologies scale favorably to the study of small mammals, generally providing more physiological information than when used on the larger human scale. This suggests that these types of small mammal imaging capabilities will play a very significant role in the full utilization of these important animal models in biomedical research.
Collapse
Affiliation(s)
- R S Balaban
- Laboratory Research Program, National Heart Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA
| | | |
Collapse
|
17
|
Abstract
Intracellular recording is a powerful electrophysiology technique that has revealed much of what is known about the biophysical properties of neurons. However, neuronal properties are strongly affected by activity dependent and modulatory influences, making it essential, ultimately, to study these properties in behaving animals. Unfortunately, intracellular recording has only been widely applied in vitro, since cardiac and respiratory pulsations make intracellular recording difficult in vivo. In awake behaving animals, spontaneous movements make intracellular recording nearly impossible. Here I present a novel technique to dynamically stabilize the position of a recording electrode relative to the brain. Physiological signals that are predictive of brain motion at the recording site, such as the electrocardiogram (EKG), respiratory pressure, or cranial motion, are used to control a piezoelectric manipulator, making possible stable intracellular recordings in awake active animals.
Collapse
Affiliation(s)
- M S Fee
- Biological Computation Research Department, Lucent Technologies, New Jersey 07974, USA.
| |
Collapse
|
18
|
Fujimoto JG, Pitris C, Boppart SA, Brezinski ME. Optical coherence tomography: an emerging technology for biomedical imaging and optical biopsy. Neoplasia 2000; 2:9-25. [PMID: 10933065 PMCID: PMC1531864 DOI: 10.1038/sj.neo.7900071] [Citation(s) in RCA: 509] [Impact Index Per Article: 21.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023] Open
Abstract
Optical coherence tomography (OCT) is an emerging technology for performing high-resolution cross-sectional imaging. OCT is analogous to ultrasound imaging, except that it uses light instead of sound. OCT can provide cross-sectional images of tissue structure on the micron scale in situ and in real time. Using OCT in combination with catheters and endoscopes enables high-resolution intraluminal imaging of organ systems. OCT can function as a type of optical biopsy and is a powerful imaging technology for medical diagnostics because unlike conventional histopathology which requires removal of a tissue specimen and processing for microscopic examination, OCT can provide images of tissue in situ and in real time. OCT can be used where standard excisional biopsy is hazardous or impossible, to reduce sampling errors associated with excisional biopsy, and to guide interventional procedures. In this paper, we review OCT technology and describe its potential biomedical and clinical applications.
Collapse
Affiliation(s)
- J G Fujimoto
- Department of Electrical Engineering and Computer Science, Massachusetts Institute of Technology, Cambridge 02139, USA
| | | | | | | |
Collapse
|
19
|
Bashkansky M, Duncan M, Goldberg L, Koplow J, Reintjes J. Characteristics of a Yb-doped superfluorescent fiber source for use in optical coherence tomography. OPTICS EXPRESS 1998; 3:305-310. [PMID: 19384373 DOI: 10.1364/oe.3.000305] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/27/2023]
Abstract
We have used a newly developed Yb-doped high-power fiber source in an optical coherence tomography (OCT) apparatus. We have analyzed various properties of interest for OCT measurements such as spectral shape, related gate width, central wavelength, bandwidth, and power output.
Collapse
|
20
|
Feldchtein F, Gelikonov V, Iksanov R, Gelikonov G, Kuranov R, Sergeev A, Gladkova N, Ourutina M, Reitze D, Warren J. In vivo OCT imaging of hard and soft tissue of the oral cavity. OPTICS EXPRESS 1998; 3:239-50. [PMID: 19384366 DOI: 10.1364/oe.3.000239] [Citation(s) in RCA: 124] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/21/2023]
Abstract
We use optical coherence tomography (OCT) to perform a comprehensive program of in vivo and in vitro structural imaging of hard and soft tissues within the oral cavity. We have imaged the different types of healthy oral mucosa as well as normal and abnormal tooth structure. OCT is able to differentiate between the various types of keratinized and non-keratinized mucosa with high resolution. OCT is also able to provide detailed structural information on clinical abnormalities (caries and non-caries lesions) in teeth and provide guidance in dental restorative procedures. Our investigations demonstrate the utility of OCT as a diagnostic imaging modality in clinical and research dentistry.
Collapse
|