1
|
Guo S, Li K, Chen Y, Li B. Unraveling the drug distribution in brain enabled by MALDI MS imaging with laser-assisted chemical transfer. Acta Pharm Sin B 2022; 12:2120-2126. [PMID: 35847487 PMCID: PMC9279630 DOI: 10.1016/j.apsb.2021.11.007] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/22/2021] [Revised: 10/24/2021] [Accepted: 11/03/2021] [Indexed: 12/15/2022] Open
Abstract
Accurate localization of central nervous system (CNS) drug distribution in the brain is quite challenging to matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI), owing to the ionization competition/suppression of highly abundant endogenous biomolecules and MALDI matrix. Herein, we developed a highly efficient sample preparation technique, laser-assisted chemical transfer (LACT), to enhance the detection sensitivity of CNS drugs in brain tissues. A focused diode laser source transilluminated the tissue slide coated with α-cyano-4-hydroxycinnamic acid, an optimal matrix to highly absorb the laser radiation at 405 nm, and a very thin-layer chemical film mainly containing drug molecule was transferred to the acceptor glass slide. Subsequently, MALDI MSI was performed on the chemical film without additional sample treatment. One major advantage of LACT is to minimize ionization competition/suppression from the tissue itself by removing abundant endogenous lipid and protein components. The superior performance of LACT led to the successful visualization of regional distribution patterns of 16 CNS drugs in the mouse brain. Furthermore, the dynamic spatial changes of risperidone and its metabolite were visualized over a 24-h period. Also, the brain-to-plasma (B/P) ratio could be obtained according to MALDI MSI results, providing an alternative means to assess brain penetration in drug discovery.
Collapse
|
2
|
Dong C, Richardson LT, Solouki T, Murray KK. Infrared Laser Ablation Microsampling with a Reflective Objective. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:463-470. [PMID: 35104132 PMCID: PMC8895455 DOI: 10.1021/jasms.1c00306] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 10/06/2021] [Revised: 01/19/2022] [Accepted: 01/20/2022] [Indexed: 06/14/2023]
Abstract
A Schwarzschild reflective objective with a numerical aperture of 0.3 and working distance of 10 cm was used for laser ablation sampling of tissue for off-line mass spectrometry. The objective focused the laser to a diameter of 5 μm and produced 10 μm ablation spots on thin ink films and tissue sections. Rat brain tissue sections 50 μm thick were ablated in transmission geometry, and the ablated material was captured in a microcentrifuge tube containing solvent. Proteins from ablated tissue sections were quantified with a Bradford assay, which indicated that approximately 300 ng of protein was captured from a 1 mm2 area of ablated tissue. Areas of tissue ranging from 0.01 to 1 mm2 were ablated and captured for bottom-up proteomics. Proteins were extracted from the captured tissue and digested for liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis for peptide and protein identification.
Collapse
Affiliation(s)
- Chao Dong
- Department
of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, United States
| | - Luke T. Richardson
- Department
of Chemistry and Biochemistry, Baylor University, Waco, Texas 76706, United States
| | - Touradj Solouki
- Department
of Chemistry and Biochemistry, Baylor University, Waco, Texas 76706, United States
| | - Kermit K. Murray
- Department
of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, United States
| |
Collapse
|
3
|
Hahn J, Moritz M, Voß H, Pelczar P, Huber S, Schlüter H. Tissue Sampling and Homogenization in the Sub-Microliter Scale with a Nanosecond Infrared Laser (NIRL) for Mass Spectrometric Proteomics. Int J Mol Sci 2021; 22:ijms221910833. [PMID: 34639174 PMCID: PMC8509473 DOI: 10.3390/ijms221910833] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/25/2021] [Revised: 09/30/2021] [Accepted: 10/02/2021] [Indexed: 12/12/2022] Open
Abstract
It was recently shown that ultrashort pulse infrared (IR) lasers, operating at the wavelength of the OH vibration stretching band of water, are highly efficient for sampling and homogenizing biological tissue. In this study we utilized a tunable nanosecond infrared laser (NIRL) for tissue sampling and homogenization with subsequent liquid chromatography tandem mass spectrometry (LC-MS/MS) analysis for mass spectrometric proteomics. For the first time, laser sampling was performed with murine spleen and colon tissue. An ablation volume of 1.1 × 1.1 × 0.4 mm³ (approximately 0.5 µL) was determined with optical coherence tomography (OCT). The results of bottom-up proteomics revealed proteins with significant abundance differences for both tissue types, which are in accordance with the corresponding data of the Human Protein Atlas. The results demonstrate that tissue sampling and homogenization of small tissue volumes less than 1 µL for subsequent mass spectrometric proteomics is feasible with a NIRL.
Collapse
Affiliation(s)
- Jan Hahn
- Section/Core Facility Mass Spectrometry and Proteomics, University Medical Center Hamburg-Eppendorf (UKE), Martinistr. 52, 20246 Hamburg, Germany; (M.M.); (H.V.); (H.S.)
- Correspondence: ; Tel.: +49-1522-2827-168
| | - Manuela Moritz
- Section/Core Facility Mass Spectrometry and Proteomics, University Medical Center Hamburg-Eppendorf (UKE), Martinistr. 52, 20246 Hamburg, Germany; (M.M.); (H.V.); (H.S.)
| | - Hannah Voß
- Section/Core Facility Mass Spectrometry and Proteomics, University Medical Center Hamburg-Eppendorf (UKE), Martinistr. 52, 20246 Hamburg, Germany; (M.M.); (H.V.); (H.S.)
| | - Penelope Pelczar
- Section of Molecular Immunology and Gastroenterology, I. Department of Medicine, University Medical Center Hamburg-Eppendorf (UKE), Martinistr. 52, 20246 Hamburg, Germany; (P.P.); (S.H.)
| | - Samuel Huber
- Section of Molecular Immunology and Gastroenterology, I. Department of Medicine, University Medical Center Hamburg-Eppendorf (UKE), Martinistr. 52, 20246 Hamburg, Germany; (P.P.); (S.H.)
| | - Hartmut Schlüter
- Section/Core Facility Mass Spectrometry and Proteomics, University Medical Center Hamburg-Eppendorf (UKE), Martinistr. 52, 20246 Hamburg, Germany; (M.M.); (H.V.); (H.S.)
| |
Collapse
|
4
|
Pulukkody AC, Yung YP, Donnarumma F, Murray KK, Carlson RP, Hanley L. Spatially resolved analysis of Pseudomonas aeruginosa biofilm proteomes measured by laser ablation sample transfer. PLoS One 2021; 16:e0250911. [PMID: 34292966 PMCID: PMC8297752 DOI: 10.1371/journal.pone.0250911] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2021] [Accepted: 06/22/2021] [Indexed: 12/18/2022] Open
Abstract
Heterogeneity in the distribution of nutrients and oxygen gradients during biofilm growth gives rise to changes in phenotype. There has been long term interest in identifying spatial differences during biofilm development including clues that identify chemical heterogeneity. Laser ablation sample transfer (LAST) allows site-specific sampling combined with label free proteomics to distinguish radially and axially resolved proteomes for Pseudomonas aeruginosa biofilms. Specifically, differential protein abundances on oxic vs. anoxic regions of a biofilm were observed by combining LAST with bottom up proteomics. This study reveals a more active metabolism in the anoxic region of the biofilm with respect to the oxic region for this clinical strain of P. aeruginosa, despite this organism being considered an aerobe by nature. Protein abundance data related to cellular acclimations to chemical gradients include identification of glucose catabolizing proteins, high abundance of proteins from arginine and polyamine metabolism, and proteins that could also support virulence and environmental stress mediation in the anoxic region. Finally, the LAST methodology requires only a few mm2 of biofilm area to identify hundreds of proteins.
Collapse
Affiliation(s)
- Aruni Chathurya Pulukkody
- Department of Chemistry, University of Illinois at Chicago, Chicago, Illinois, United States of America
| | - Yeni P. Yung
- Department of Chemistry, University of Illinois at Chicago, Chicago, Illinois, United States of America
| | - Fabrizio Donnarumma
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana, United States of America
| | - Kermit K. Murray
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana, United States of America
| | - Ross P. Carlson
- Department of Chemical and Biological Engineering, Center for Biofilm Engineering, Montana State University, Bozeman, Montana, United States of America
| | - Luke Hanley
- Department of Chemistry, University of Illinois at Chicago, Chicago, Illinois, United States of America
| |
Collapse
|
5
|
Kertesz V, Cahill JF. Spatially resolved absolute quantitation in thin tissue by mass spectrometry. Anal Bioanal Chem 2021; 413:2619-2636. [PMID: 33140126 DOI: 10.1007/s00216-020-02964-3] [Citation(s) in RCA: 14] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Mass spectrometry (MS) has become the de facto tool for routine quantitative analysis of biomolecules. MS is increasingly being used to reveal the spatial distribution of proteins, metabolites, and pharmaceuticals in tissue and interest in this area has led to a number of novel spatially resolved MS technologies. Most spatially resolved MS measurements are qualitative in nature due to a myriad of potential biases, such as sample heterogeneity, sampling artifacts, and ionization effects. As applications of spatially resolved MS in the pharmacological and clinical fields increase, demand has become high for quantitative MS imaging and profiling data. As a result, several varied technologies now exist that provide differing levels of spatial and quantitative information. This review provides an overview of MS profiling and imaging technologies that have demonstrated quantitative analysis from tissue. Focus is given on the fundamental processes affecting quantitative analysis in an array of MS imaging and profiling technologies and methods to address these biases.Graphical abstract.
Collapse
Affiliation(s)
- Vilmos Kertesz
- Oak Ridge National Laboratory, Oak Ridge, TN, 37831-6131, USA.
| | - John F Cahill
- Oak Ridge National Laboratory, Oak Ridge, TN, 37831-6131, USA.
| |
Collapse
|
6
|
Wang K, Donnarumma F, Pettit ME, Szot CW, Solouki T, Murray KK. MALDI imaging directed laser ablation tissue microsampling for data independent acquisition proteomics. JOURNAL OF MASS SPECTROMETRY : JMS 2020; 55:e4475. [PMID: 31726477 DOI: 10.1002/jms.4475] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/22/2019] [Revised: 10/25/2019] [Accepted: 11/07/2019] [Indexed: 06/10/2023]
Abstract
A multimodal workflow for mass spectrometry imaging was developed that combines MALDI imaging with protein identification and quantification by liquid chromatography tandem mass spectrometry (LC-MS/MS). Thin tissue sections were analyzed by MALDI imaging, and the regions of interest (ROI) were identified using a smoothing and edge detection procedure. A midinfrared laser at 3-μm wavelength was used to remove the ROI from the brain tissue section after MALDI mass spectrometry imaging (MALDI MSI). The captured material was processed using a single-pot solid-phase-enhanced sample preparation (SP3) method and analyzed by LC-MS/MS using ion mobility (IM) enhanced data independent acquisition (DIA) to identify and quantify proteins; more than 600 proteins were identified. Using a modified database that included isoform and the post-translational modifications chain, loss of the initial methionine, and acetylation, 14 MALDI MSI peaks were identified. Comparison of the Kyoto Encyclopedia of Genes and Genomes (KEGG) pathways of the identified proteins was achieved through an evolutionary relationships classification system.
Collapse
Affiliation(s)
- Kelin Wang
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, United States
| | - Fabrizio Donnarumma
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, United States
| | - Michael E Pettit
- Department of Chemistry and Biochemistry, Baylor University, Waco, TX, 76706, United States
| | - Carson W Szot
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, United States
| | - Touradj Solouki
- Department of Chemistry and Biochemistry, Baylor University, Waco, TX, 76706, United States
| | - Kermit K Murray
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, United States
| |
Collapse
|
7
|
Wang K, Donnarumma F, Herke SW, Dong C, Herke PF, Murray KK. RNA sampling from tissue sections using infrared laser ablation. Anal Chim Acta 2019; 1063:91-98. [PMID: 30967191 DOI: 10.1016/j.aca.2019.02.054] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/17/2018] [Revised: 02/17/2019] [Accepted: 02/24/2019] [Indexed: 10/27/2022]
Abstract
RNA was obtained from discrete locations of frozen rat brain tissue sections through infrared (IR) laser ablation using a 3-μm wavelength in transmission geometry. The ablated plume was captured in a microcentrifuge tube containing RNAse-free buffer and processed using a commercial RNA purification kit. RNA transfer efficiency and integrity were evaluated based on automated electrophoresis in microfluidic chips. Reproducible IR-laser ablation of intact RNA was demonstrated with purified RNA at laser fluences of 3-5 kJ/m2 (72 ± 12% transfer efficiency) and with tissue sections at a laser fluence of 13 kJ/m2 (79 ± 14% transfer efficiency); laser energies were attenuated ∼20% by the soda-lime glass slides used to support the samples. RNA integrity from tissue ablation was >90% of its original RIN value (∼7) and the purified RNA was sufficiently intact for conversion to cDNA and subsequent qPCR assay.
Collapse
Affiliation(s)
- Kelin Wang
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, United States
| | - Fabrizio Donnarumma
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, United States
| | - Scott W Herke
- Genomics Facility, College of Science, Louisiana State University, Baton Rouge, LA, 70803, United States
| | - Chao Dong
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, United States
| | - Patrick F Herke
- Genomics Facility, College of Science, Louisiana State University, Baton Rouge, LA, 70803, United States
| | - Kermit K Murray
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, United States.
| |
Collapse
|
8
|
Donnarumma F, Camp EE, Cao F, Murray KK. Infrared Laser Ablation with Vacuum Capture for Fingermark Sampling. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:1958-1964. [PMID: 28534157 DOI: 10.1007/s13361-017-1703-2] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2017] [Revised: 04/26/2017] [Accepted: 04/30/2017] [Indexed: 06/07/2023]
Abstract
Infrared laser ablation coupled to vacuum capture was employed to collect material from fingermarks deposited on surfaces of different porosity and roughness. Laser ablation at 3 μm was performed in reflection mode with subsequent capture of the ejecta with a filter connected to vacuum. Ablation and capture of standards from fingermarks was demonstrated on glass, plastic, aluminum, and cardboard surfaces. Using matrix assisted laser desorption ionization (MALDI), it was possible to detect caffeine after spiking with amounts as low as 1 ng. MALDI detection of condom lubricants and detection of antibacterial peptides from an antiseptic cream was demonstrated. Detection of explosives from fingermarks left on plastic surfaces as well as from direct deposition on the same surface using gas chromatography mass spectrometry (GC-MS) was shown. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Fabrizio Donnarumma
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA
| | - Eden E Camp
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA
| | - Fan Cao
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA
| | - Kermit K Murray
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA.
| |
Collapse
|
9
|
Infrared laser ablation sample transfer of tissue DNA for genomic analysis. Anal Bioanal Chem 2017; 409:4119-4126. [DOI: 10.1007/s00216-017-0373-z] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/08/2017] [Accepted: 04/20/2017] [Indexed: 01/01/2023]
|
10
|
Murray KK, Seneviratne CA, Ghorai S. High resolution laser mass spectrometry bioimaging. Methods 2016; 104:118-26. [PMID: 26972785 PMCID: PMC4937799 DOI: 10.1016/j.ymeth.2016.03.002] [Citation(s) in RCA: 35] [Impact Index Per Article: 3.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/07/2015] [Revised: 02/23/2016] [Accepted: 03/08/2016] [Indexed: 12/11/2022] Open
Abstract
Mass spectrometry imaging (MSI) was introduced more than five decades ago with secondary ion mass spectrometry (SIMS) and a decade later with laser desorption/ionization (LDI) mass spectrometry (MS). Large biomolecule imaging by matrix-assisted laser desorption/ionization (MALDI) was developed in the 1990s and ambient laser MS a decade ago. Although SIMS has been capable of imaging with a moderate mass range at sub-micrometer lateral resolution from its inception, laser MS requires additional effort to achieve a lateral resolution of 10μm or below which is required to image at the size scale of single mammalian cells. This review covers untargeted large biomolecule MSI using lasers for desorption/ionization or laser desorption and post-ionization. These methods include laser microprobe (LDI) MSI, MALDI MSI, laser ambient and atmospheric pressure MSI, and near-field laser ablation MS. Novel approaches to improving lateral resolution are discussed, including oversampling, beam shaping, transmission geometry, reflective and through-hole objectives, microscope mode, and near-field optics.
Collapse
Affiliation(s)
- Kermit K Murray
- Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803, USA.
| | | | - Suman Ghorai
- Department of Chemistry, Louisiana State University, Baton Rouge, LA 70803, USA
| |
Collapse
|
11
|
Donnarumma F, Murray KK. Laser ablation sample transfer for localized LC-MS/MS proteomic analysis of tissue. JOURNAL OF MASS SPECTROMETRY : JMS 2016; 51:261-8. [PMID: 27041656 DOI: 10.1002/jms.3744] [Citation(s) in RCA: 17] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/05/2015] [Revised: 01/04/2016] [Accepted: 01/05/2016] [Indexed: 05/25/2023]
Abstract
We have developed a mid-infrared laser ablation sampling technique for nano-flow liquid chromatography coupled with tandem mass spectrometry proteomic profiling of discrete regions from biological samples. Laser ablation performed in transmission geometry was used to transfer material from 50-µm thick tissue sections mounted on a glass microscope slide to a capturing solvent. Captured samples were processed using filter-aided sample preparation and enzymatically digested to produce tryptic peptides for data-dependent analysis with an ion trap mass spectrometer. Comparison with ultraviolet laser capture microdissection from neighboring regions on the same tissue section revealed that infrared laser ablation transfer has higher reproducibility between samples from different consecutive sections. Both techniques allowed for proteomics investigation of different organelles without the addition of surfactants.
Collapse
Affiliation(s)
- Fabrizio Donnarumma
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana, 70803, USA
| | - Kermit K Murray
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana, 70803, USA
| |
Collapse
|
12
|
Donnarumma F, Cao F, Murray KK. Laser Ablation with Vacuum Capture for MALDI Mass Spectrometry of Tissue. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2016; 27:108-116. [PMID: 26374229 DOI: 10.1007/s13361-015-1249-0] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/22/2015] [Revised: 08/04/2015] [Accepted: 08/08/2015] [Indexed: 06/05/2023]
Abstract
We have developed a laser ablation sampling technique for matrix-assisted laser desorption ionization (MALDI) mass spectrometry and tandem mass spectrometry (MS/MS) analyses of in-situ digested tissue proteins. Infrared laser ablation was used to remove biomolecules from tissue sections for collection by vacuum capture and analysis by MALDI. Ablation and transfer of compounds from tissue removes biomolecules from the tissue and allows further analysis of the collected material to facilitate their identification. Laser ablated material was captured in a vacuum aspirated pipette-tip packed with C18 stationary phase and the captured material was dissolved, eluted, and analyzed by MALDI. Rat brain and lung tissue sections 10 μm thick were processed by in-situ trypsin digestion after lipid and salt removal. The tryptic peptides were ablated with a focused mid-infrared laser, vacuum captured, and eluted with an acetonitrile/water mixture. Eluted components were deposited on a MALDI target and mixed with matrix for mass spectrometry analysis. Initial experiments were conducted with peptide and protein standards for evaluation of transfer efficiency: a transfer efficiency of 16% was obtained using seven different standards. Laser ablation vacuum capture was applied to freshly digested tissue sections and compared with sections processed with conventional MALDI imaging. A greater signal intensity and lower background was observed in comparison with the conventional MALDI analysis. Tandem time-of-flight MALDI mass spectrometry was used for compound identification in the tissue.
Collapse
Affiliation(s)
- Fabrizio Donnarumma
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA
| | - Fan Cao
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA
| | - Kermit K Murray
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA.
| |
Collapse
|
13
|
Fatou B, Wisztorski M, Focsa C, Salzet M, Ziskind M, Fournier I. Substrate-Mediated Laser Ablation under Ambient Conditions for Spatially-Resolved Tissue Proteomics. Sci Rep 2015; 5:18135. [PMID: 26674367 PMCID: PMC4682183 DOI: 10.1038/srep18135] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/06/2015] [Accepted: 11/13/2015] [Indexed: 01/06/2023] Open
Abstract
Numerous applications of ambient Mass Spectrometry (MS) have been demonstrated over the past decade. They promoted the emergence of various micro-sampling techniques such as Laser Ablation/Droplet Capture (LADC). LADC consists in the ablation of analytes from a surface and their subsequent capture in a solvent droplet which can then be analyzed by MS. LADC is thus generally performed in the UV or IR range, using a wavelength at which analytes or the matrix absorb. In this work, we explore the potential of visible range LADC (532 nm) as a micro-sampling technology for large-scale proteomics analyses. We demonstrate that biomolecule analyses using 532 nm LADC are possible, despite the low absorbance of biomolecules at this wavelength. This is due to the preponderance of an indirect substrate-mediated ablation mechanism at low laser energy which contrasts with the conventional direct ablation driven by sample absorption. Using our custom LADC system and taking advantage of this substrate-mediated ablation mechanism, we were able to perform large-scale proteomic analyses of micro-sampled tissue sections and demonstrated the possible identification of proteins with relevant biological functions. Consequently, the 532 nm LADC technique offers a new tool for biological and clinical applications.
Collapse
Affiliation(s)
- Benoit Fatou
- Univ. Lille, INSERM, U1192 - Laboratoire Protéomique, Réponse Inflammatoire et Spectrométrie de Masse-PRISM, F-59000 Lille, France.,Univ. Lille, CNRS, UMR 8523 - PhLAM - Physique des Lasers Atomes et Molécules, F-59000 Lille, France
| | - Maxence Wisztorski
- Univ. Lille, INSERM, U1192 - Laboratoire Protéomique, Réponse Inflammatoire et Spectrométrie de Masse-PRISM, F-59000 Lille, France
| | - Cristian Focsa
- Univ. Lille, CNRS, UMR 8523 - PhLAM - Physique des Lasers Atomes et Molécules, F-59000 Lille, France
| | - Michel Salzet
- Univ. Lille, INSERM, U1192 - Laboratoire Protéomique, Réponse Inflammatoire et Spectrométrie de Masse-PRISM, F-59000 Lille, France
| | - Michael Ziskind
- Univ. Lille, CNRS, UMR 8523 - PhLAM - Physique des Lasers Atomes et Molécules, F-59000 Lille, France
| | - Isabelle Fournier
- Univ. Lille, INSERM, U1192 - Laboratoire Protéomique, Réponse Inflammatoire et Spectrométrie de Masse-PRISM, F-59000 Lille, France
| |
Collapse
|
14
|
Cao F, Donnarumma F, Murray KK. Particle size measurement from infrared laser ablation of tissue. Analyst 2015; 141:183-90. [PMID: 26630332 DOI: 10.1039/c5an01765c] [Citation(s) in RCA: 8] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
The concentration and size distribution were measured for particles ablated from tissue sections using an infrared optical parametric oscillator laser system. A scanning mobility particle sizer and light scattering particle sizer were used in parallel to realize a particle sizing range from 10 nm to 20 μm. Tissue sections from rat brain and lung ranging in thickness between 10 and 50 μm were mounted on microscope slides and irradiated with nanosecond laser pulses at 3 μm wavelength and fluences between 7 and 21 kJ m(-2) in reflection geometry. The particle size distributions were characterized by a bimodal distribution with a large number of particles 100 nm in diameter and below and a large mass contribution from particles greater than 1 μm in diameter. The large particle contribution dominated the ablated particle mass at high laser fluence. The tissue type, thickness, and water content did not have a significant effect on the particle size distributions. The implications of these results for laser ablation sampling and mass spectrometry imaging under ambient conditions are discussed.
Collapse
Affiliation(s)
- Fan Cao
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana. 70803, USA.
| | | | | |
Collapse
|
15
|
Boughton BA, Thinagaran D, Sarabia D, Bacic A, Roessner U. Mass spectrometry imaging for plant biology: a review. PHYTOCHEMISTRY REVIEWS : PROCEEDINGS OF THE PHYTOCHEMICAL SOCIETY OF EUROPE 2015; 15:445-488. [PMID: 27340381 PMCID: PMC4870303 DOI: 10.1007/s11101-015-9440-2] [Citation(s) in RCA: 171] [Impact Index Per Article: 17.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/18/2015] [Accepted: 09/25/2015] [Indexed: 05/09/2023]
Abstract
Mass spectrometry imaging (MSI) is a developing technique to measure the spatio-temporal distribution of many biomolecules in tissues. Over the preceding decade, MSI has been adopted by plant biologists and applied in a broad range of areas, including primary metabolism, natural products, plant defense, plant responses to abiotic and biotic stress, plant lipids and the developing field of spatial metabolomics. This review covers recent advances in plant-based MSI, general aspects of instrumentation, analytical approaches, sample preparation and the current trends in respective plant research.
Collapse
Affiliation(s)
- Berin A. Boughton
- />Metabolomics Australia, School of BioSciences, The University of Melbourne, Parkville, VIC 3010 Australia
| | - Dinaiz Thinagaran
- />School of BioSciences, The University of Melbourne, Parkville, VIC 3010 Australia
| | - Daniel Sarabia
- />School of BioSciences, The University of Melbourne, Parkville, VIC 3010 Australia
| | - Antony Bacic
- />School of BioSciences, The University of Melbourne, Parkville, VIC 3010 Australia
- />ARC Centre of Excellence in Plant Cell Walls, School of BioSciences, University of Melbourne, Parkville, VIC 3010 Australia
- />Bio21 Molecular Science and Biotechnology Institute, University of Melbourne, Parkville, VIC 3010 Australia
| | - Ute Roessner
- />School of BioSciences, The University of Melbourne, Parkville, VIC 3010 Australia
| |
Collapse
|
16
|
Kwiatkowski M, Wurlitzer M, Omidi M, Ren L, Kruber S, Nimer R, Robertson WD, Horst A, Miller RJD, Schlüter H. Desorption durch impulsive Anregung intramolekularer Vibrationszustände – eine Methode zur schnellen Extraktion von Proteinen aus intakten Geweben. Angew Chem Int Ed Engl 2015. [DOI: 10.1002/ange.201407669] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/08/2022]
Affiliation(s)
- Marcel Kwiatkowski
- Universitätsklinikum Hamburg‐Eppendorf, Institut für Klinische Chemie, Martinistraße 52, Hamburg, 20246 (Deutschland)
| | - Marcus Wurlitzer
- Universitätsklinikum Hamburg‐Eppendorf, Institut für Klinische Chemie, Martinistraße 52, Hamburg, 20246 (Deutschland)
| | - Maryam Omidi
- Universitätsklinikum Hamburg‐Eppendorf, Institut für Klinische Chemie, Martinistraße 52, Hamburg, 20246 (Deutschland)
| | - Ling Ren
- Max‐Planck‐Institut für Struktur und Dynamik der Materie, CFEL (Gebäude 99), Luruper Chaussee 149, Hamburg, 22761 (Deutschland)
| | - Sebastian Kruber
- Max‐Planck‐Institut für Struktur und Dynamik der Materie, CFEL (Gebäude 99), Luruper Chaussee 149, Hamburg, 22761 (Deutschland)
| | - Refat Nimer
- Universitätsklinikum Hamburg‐Eppendorf, Institut für Klinische Chemie, Martinistraße 52, Hamburg, 20246 (Deutschland)
| | - Wesley D. Robertson
- Max‐Planck‐Institut für Struktur und Dynamik der Materie, CFEL (Gebäude 99), Luruper Chaussee 149, Hamburg, 22761 (Deutschland)
| | - Andrea Horst
- Universitätsklinikum Hamburg‐Eppendorf, Institut für Klinische Chemie, Martinistraße 52, Hamburg, 20246 (Deutschland)
| | - R. J. Dwayne Miller
- Max‐Planck‐Institut für Struktur und Dynamik der Materie, CFEL (Gebäude 99), Luruper Chaussee 149, Hamburg, 22761 (Deutschland)
| | - Hartmut Schlüter
- Universitätsklinikum Hamburg‐Eppendorf, Institut für Klinische Chemie, Martinistraße 52, Hamburg, 20246 (Deutschland)
| |
Collapse
|
17
|
Abstract
Infrared laser ablation sample transfer (IR-LAST) is a novel ambient sampling technique for mass spectrometry. In this technique, a pulsed mid-IR laser is used to ablate materials that are collected for mass spectrometry analysis; the material can be a solid sample or deposited on a sample target. After collection, the sample can be further separated or analyzed directly by mass spectrometry. For IR-LAST sample transfer tissue imaging using MALDI mass spectrometry, a tissue section is placed on a sample slide and material transferred to a target slide by scanning the tissue sample under a focused laser beam using transmission-mode (back side) IR laser ablation. After transfer, the target slide is analyzed using MALDI imaging. The spatial resolution is approximately 400 μm and limited by the spread of the laser desorption plume. IR-LAST for MALDI imaging provides several new capabilities including ambient sampling, area to spot concentration of ablated material, multiple ablation and analysis from a single section, and direct deposition on matrix-free nanostructured targets.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA
| | | |
Collapse
|
18
|
Ghorai S, Seneviratne CA, Murray KK. Tip-enhanced laser ablation sample transfer for biomolecule mass spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2015; 26:63-70. [PMID: 25287125 PMCID: PMC4276512 DOI: 10.1007/s13361-014-1005-x] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/12/2014] [Revised: 09/10/2014] [Accepted: 09/11/2014] [Indexed: 06/03/2023]
Abstract
Atomic force microscope (AFM) tip-enhanced laser ablation was used to transfer molecules from thin films to a suspended silver wire for off-line mass spectrometry using laser desorption ionization (LDI) and matrix-assisted laser desorption ionization (MALDI). An AFM with a 30 nm radius gold-coated silicon tip was used to image the sample and to hold the tip 15 nm from the surface for material removal using a 355 nm Nd:YAG laser. The ablated material was captured on a silver wire that was held 300 μm vertically and 100 μm horizontally from the tip. For the small molecules anthracene and rhodamine 6G, the wire was cut and affixed to a metal target using double-sided conductive tape and analyzed by LDI using a commercial laser desorption time-of-flight mass spectrometer. Approximately 100 fg of material was ablated from each of the 1 μm ablation spots and transferred with approximately 3% efficiency. For larger polypeptide molecules angiotensin II and bovine insulin, the captured material was dissolved in saturated matrix solution and deposited on a target for MALDI analysis.
Collapse
Affiliation(s)
- Suman Ghorai
- Louisiana State University, Louisiana State University, Baton Rouge, Louisiana, 70803, USA
| | | | - Kermit K. Murray
- Louisiana State University, Louisiana State University, Baton Rouge, Louisiana, 70803, USA
| |
Collapse
|
19
|
Kwiatkowski M, Wurlitzer M, Omidi M, Ren L, Kruber S, Nimer R, Robertson WD, Horst A, Miller RJD, Schlüter H. Ultrafast Extraction of Proteins from Tissues Using Desorption by Impulsive Vibrational Excitation. Angew Chem Int Ed Engl 2014; 54:285-8. [DOI: 10.1002/anie.201407669] [Citation(s) in RCA: 39] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/28/2014] [Indexed: 01/07/2023]
Affiliation(s)
- Marcel Kwiatkowski
- University Medical Center Hamburg‐Eppendorf, Department of Clinical Chemistry, Martinistrasse 52, Hamburg, 20246 (Germany)
| | - Marcus Wurlitzer
- University Medical Center Hamburg‐Eppendorf, Department of Clinical Chemistry, Martinistrasse 52, Hamburg, 20246 (Germany)
| | - Maryam Omidi
- University Medical Center Hamburg‐Eppendorf, Department of Clinical Chemistry, Martinistrasse 52, Hamburg, 20246 (Germany)
| | - Ling Ren
- Max Planck Institute for the Structure and Dynamics of Matter, CFEL (Building 99), Luruper Chaussee 149, 22761 Hamburg (Germany)
| | - Sebastian Kruber
- Max Planck Institute for the Structure and Dynamics of Matter, CFEL (Building 99), Luruper Chaussee 149, 22761 Hamburg (Germany)
| | - Refat Nimer
- University Medical Center Hamburg‐Eppendorf, Department of Clinical Chemistry, Martinistrasse 52, Hamburg, 20246 (Germany)
| | - Wesley D. Robertson
- Max Planck Institute for the Structure and Dynamics of Matter, CFEL (Building 99), Luruper Chaussee 149, 22761 Hamburg (Germany)
| | - Andrea Horst
- University Medical Center Hamburg‐Eppendorf, Department of Clinical Chemistry, Martinistrasse 52, Hamburg, 20246 (Germany)
| | - R. J. Dwayne Miller
- Max Planck Institute for the Structure and Dynamics of Matter, CFEL (Building 99), Luruper Chaussee 149, 22761 Hamburg (Germany)
| | - Hartmut Schlüter
- University Medical Center Hamburg‐Eppendorf, Department of Clinical Chemistry, Martinistrasse 52, Hamburg, 20246 (Germany)
| |
Collapse
|
20
|
Musapelo T, Murray KK. Particle formation by infrared laser ablation of MALDI matrix compounds. JOURNAL OF MASS SPECTROMETRY : JMS 2014; 49:543-549. [PMID: 25044838 DOI: 10.1002/jms.3378] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/15/2013] [Revised: 04/15/2014] [Accepted: 04/15/2014] [Indexed: 06/03/2023]
Abstract
The concentration and size distribution of particles ablated from the infrared matrix-assisted laser desorption/ionization matrix compounds succinic acid (butanedioic acid), α-cyano-4-hydroxycinnamic acid, and glycerol were measured using an aerodynamic particle sizer combined with a scanning mobility particle sizer. The two sizing instruments together had a sizing range to from 10 nm to 20 µm. Thin layers of the matrix compounds were irradiated with fluences between 6.0 and 9.5 kJ/m(2) and wavelengths between 2.8 and 3.0 µm. The distribution of particles was characterized by a large concentration of clusters in the 20-nm-diameter range and large component of mass in the range of coarse particle with diameters greater than 1 µm. The wavelength dependence revealed a blue shift for the maximum particle production that is attributed to heating and disruption of the hydrogen bonds in the matrix that shifts the absorption to shorter wavelengths. This blue shift has been observed previously in infrared matrix-assisted laser desorption/ionization.
Collapse
Affiliation(s)
- Thabiso Musapelo
- Department of Chemistry, Louisiana State University, Baton Rouge, LA, 70803, USA
| | | |
Collapse
|
21
|
Kaufman E, Smith W, Kowalski M, Beech I, Sunner J. Electric-field-enhanced collection of laser-ablated materials onto a solvent bridge for electrospray ionization mass spectrometry. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2013; 27:1567-1572. [PMID: 23722691 DOI: 10.1002/rcm.6600] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/20/2012] [Revised: 04/07/2013] [Accepted: 04/15/2013] [Indexed: 06/02/2023]
Abstract
RATIONALE Ambient imaging mass spectrometry methods are critically dependent on the ability to efficiently collect all substances from a well-defined area of the sample. Improvements in this area are critical and enabling. METHODS Methods for the efficient collection of laser-ablated materials directly into a solvent, for immediate transport to an ion source, have been explored using the application of electric fields. RESULTS Electric-field-enhanced collection of laser-ablated materials has been demonstrated. Demonstrated increases in collection efficiency are as large as two orders of magnitude, in particular for hydrated biological materials, such as living bacterial colonies. This was achieved by applying approximately 1 kV between the sample and the receiving solvent surface. CONCLUSIONS Electric-field-enhanced collection of laser-ablated materials holds great promise for ambient sampling and imaging mass spectrometry with rapid and direct interfacing to ionization sources, such as electrospray.
Collapse
Affiliation(s)
- Eric Kaufman
- Department of Microbiology and Plant Biology, University of Oklahoma, Norman, OK 73019-5251, USA
| | | | | | | | | |
Collapse
|
22
|
Surface analysis of lipids by mass spectrometry: more than just imaging. Prog Lipid Res 2013; 52:329-53. [PMID: 23623802 DOI: 10.1016/j.plipres.2013.04.005] [Citation(s) in RCA: 77] [Impact Index Per Article: 6.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2012] [Revised: 03/19/2013] [Accepted: 04/12/2013] [Indexed: 11/22/2022]
Abstract
Mass spectrometry is now an indispensable tool for lipid analysis and is arguably the driving force in the renaissance of lipid research. In its various forms, mass spectrometry is uniquely capable of resolving the extensive compositional and structural diversity of lipids in biological systems. Furthermore, it provides the ability to accurately quantify molecular-level changes in lipid populations associated with changes in metabolism and environment; bringing lipid science to the "omics" age. The recent explosion of mass spectrometry-based surface analysis techniques is fuelling further expansion of the lipidomics field. This is evidenced by the numerous papers published on the subject of mass spectrometric imaging of lipids in recent years. While imaging mass spectrometry provides new and exciting possibilities, it is but one of the many opportunities direct surface analysis offers the lipid researcher. In this review we describe the current state-of-the-art in the direct surface analysis of lipids with a focus on tissue sections, intact cells and thin-layer chromatography substrates. The suitability of these different approaches towards analysis of the major lipid classes along with their current and potential applications in the field of lipid analysis are evaluated.
Collapse
|
23
|
Monge ME, Harris GA, Dwivedi P, Fernández FM. Mass Spectrometry: Recent Advances in Direct Open Air Surface Sampling/Ionization. Chem Rev 2013; 113:2269-308. [DOI: 10.1021/cr300309q] [Citation(s) in RCA: 404] [Impact Index Per Article: 33.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- María Eugenia Monge
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332,
United States
| | - Glenn A. Harris
- Department
of Biochemistry and
the Mass Spectrometry Research Center, Vanderbilt University, Nashville, Tennessee 37235, United States
| | - Prabha Dwivedi
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332,
United States
| | - Facundo M. Fernández
- School of Chemistry and Biochemistry, Georgia Institute of Technology, Atlanta, Georgia 30332,
United States
| |
Collapse
|
24
|
Park SG, Murray KK. Infrared laser ablation sample transfer for on-line liquid chromatography electrospray ionization mass spectrometry. JOURNAL OF MASS SPECTROMETRY : JMS 2012; 47:1322-1326. [PMID: 23019163 DOI: 10.1002/jms.3096] [Citation(s) in RCA: 36] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/01/2023]
Abstract
We have demonstrated an on-line laser ablation sampling system and coupling of the system to liquid chromatography (LC) using an infrared (IR) laser to ablate and transfer materials into a flowing solvent stream. With this approach, samples are deposited on a microscope slide mounted on a translation stage and ablated in transmission geometry using a pulsed mid-IR laser. The ablated material is captured in an exposed flowing solvent stream that carries the ablated material to the electrospray source. Post-ablation separation is accomplished using a capillary column downstream of the capture zone. The performance of the system was assessed using peptide and protein mixtures ablated from the target and analyzed with and without LC separation.
Collapse
Affiliation(s)
- Sung-Gun Park
- Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, USA
| | | |
Collapse
|