1
|
Van Assche CXL, Krüger DN, Flinders B, Vandenbosch M, Franssen C, Guns PJD, Heeren RMA, Cillero-Pastor B. Improved on-tissue detection of the anti-cancer agent doxorubicin by quantitative matrix-assisted laser desorption/ionization mass spectrometry imaging. Talanta 2024; 271:125667. [PMID: 38245959 DOI: 10.1016/j.talanta.2024.125667] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/01/2023] [Revised: 12/18/2023] [Accepted: 01/12/2024] [Indexed: 01/23/2024]
Abstract
Doxorubicin (dox) is an affordable, and highly effective chemotherapeutic agent used in cancer treatment, yet its application is known to cause cumulative cardiac and renal toxicity. In this study, we employed matrix-assisted laser desorption/ionization-mass spectrometry imaging (MALDI-MSI) to evaluate the distribution of dox in mouse heart and kidney after in vivo treatment. To this end, we performed absolute quantification using an isotopically labeled form (13C d3-dox) as an internal standard. Unfortunately, ion suppression often leads to loss of sensitivity in compound detection and can result in hampered drug quantification. To overcome this issue, we developed an on-tissue chemical derivatization (OTCD) method using Girard's reagent T (GirT). With the developed method, dox signal was increased by two orders of magnitude. This optimized sample preparation enabled a sensible gain in dox detection, making it possible to study its distribution and abundance (up to 0.11 pmol/mm2 in the heart and 0.33 pmol/mm2 in the kidney medulla). The optimized approach for on-tissue derivatization and subsequent quantification creates a powerful tool to better understand the relationship between dox exposure (at clinically relevant concentrations) and its biological detrimental effects in various tissues. Overall, this work is a showcase of the added value of MALDI-MSI for pharmaceutical studies to better understand heterogeneity in drug exposure between and within organs.
Collapse
Affiliation(s)
- Charles X L Van Assche
- Maastricht Multimodal Molecular Imaging institute (M4i), Maastricht University, Maastricht, Netherlands
| | - Dustin N Krüger
- Laboratory of Physiopharmacology, Faculty of Medicine and Health Sciences, Faculty of Pharmaceutical, Biomedical and Veterinary Sciences, Campus Drie Eiken, University of Antwerp, Antwerp B-2610, Belgium
| | - Bryn Flinders
- Maastricht Multimodal Molecular Imaging institute (M4i), Maastricht University, Maastricht, Netherlands
| | - Michiel Vandenbosch
- Maastricht Multimodal Molecular Imaging institute (M4i), Maastricht University, Maastricht, Netherlands
| | - Constantijn Franssen
- Research Group Cardiovascular Diseases, GENCOR, University of Antwerp, B-2610 Antwerp, Belgium; Department of Cardiology, Antwerp University Hospital (UZA), Drie Eikenstraat 655, Edegem, Belgium
| | - Pieter-Jan D Guns
- Laboratory of Physiopharmacology, Faculty of Medicine and Health Sciences, Faculty of Pharmaceutical, Biomedical and Veterinary Sciences, Campus Drie Eiken, University of Antwerp, Antwerp B-2610, Belgium
| | - Ron M A Heeren
- Maastricht Multimodal Molecular Imaging institute (M4i), Maastricht University, Maastricht, Netherlands
| | - Berta Cillero-Pastor
- Maastricht Multimodal Molecular Imaging institute (M4i), Maastricht University, Maastricht, Netherlands; Institute for Technology-Inspired Regenerative Medicine (MERLN), Department of Cell Biology-Inspired Tissue Engineering, Maastricht University, Maastricht, Netherlands.
| |
Collapse
|
2
|
Bell RJ, Hage DS, Dodds ED. Two-Dimensional Fourier Transform Ion Cyclotron Resonance Mass Spectrometry by Matrix-Assisted Laser Desorption Ionization. Anal Chem 2024; 96:6584-6587. [PMID: 38619932 DOI: 10.1021/acs.analchem.3c05601] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/17/2024]
Abstract
Two-dimensional Fourier transform ion cyclotron resonance (2D FTICR) mass spectrometry is a developing form of data-independent acquisition that allows for the simultaneous fragmentation and correlation of fragment ions to their precursors across a range of m/z values. The modern usage of 2D FTICR is performed using electrospray ionization (ESI) as the dried droplet preparation for matrix-assisted laser desorption ionization (MALDI) does not produce a consistent packet of ions over a number of scans. This work uses pneumatic spray techniques from mass spectrometry imaging to create a homogeneous surface for use with MALDI as an ionization source for 2D FTICR. A mixture of peptides and matrix was deposited onto a glass slide using an HTX pneumatic sprayer. MALDI was then used to ionize the peptide mixture for use with a standard 2D FTICR pulse sequence. The generated 2D spectrum reveals comparable structural information to spectra collected in a 1D experiment. Artifacts observed in the collected 2D MALDI spectra do not significantly differ from those expected from 2D ESI spectra.
Collapse
Affiliation(s)
- Richard J Bell
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, United States
| | - David S Hage
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, United States
| | - Eric D Dodds
- Department of Chemistry, University of Nebraska-Lincoln, Lincoln, Nebraska 68588-0304, United States
| |
Collapse
|
3
|
Russo C, Clench MR. Spatially Resolved Quantitation of Drug in Skin Equivalents Using Mass Spectrometry Imaging (MSI). Methods Mol Biol 2023; 2688:27-40. [PMID: 37410281 DOI: 10.1007/978-1-0716-3319-9_3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/07/2023]
Abstract
Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) has seen a growing interest as a leading technique in the pharmaceutical industry for mapping label-free exogenous and endogenous species in biological tissues. However, the use of MALDI-MSI to perform spatially resolved absolute quantitation of species directly in tissues is still challenging, and robust quantitative mass spectrometry imaging (QMSI) methods need to be developed. In this study, we describe the microspotting technique for analytical and internal standard deposition, matrix sublimation, powerful QMSI software, and mass spectrometry imaging setup to obtain absolute quantitation of drug distribution in 3D skin models.
Collapse
Affiliation(s)
- Cristina Russo
- Centre for Mass Spectrometry Imaging, Biomolecular Sciences Research Centre, Sheffield Hallam University, Sheffield, UK.
- Department of Natural Sciences, Middlesex University, London, UK.
| | - Malcolm R Clench
- Centre for Mass Spectrometry Imaging, Biomolecular Sciences Research Centre, Sheffield Hallam University, Sheffield, UK
| |
Collapse
|
4
|
Wu Q. A review on quantitation-related factors and quantitation strategies in mass spectrometry imaging of small biomolecules. ANALYTICAL METHODS : ADVANCING METHODS AND APPLICATIONS 2022; 14:3932-3943. [PMID: 36164961 DOI: 10.1039/d2ay01257j] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/16/2023]
Abstract
Accurate quantitative information of the analytes in mass spectrometry imaging (MSI) is fundamental for determining the accurate spatial distribution, which can provide additional insight into the living processes, disease progression or the pharmacokinetic-pharmacodynamic mechanisms. However, performing a quantitative analysis in MSI is still challenging. This review focuses on the quantitation-related factors and recent advances in the strategies of quantitative MSI (q-MSI) of small molecules. The main quantitation-related factors are discussed according to the new investigations in recent years, including the regionally varied extraction efficiencies and ionization efficiencies, signal-concentration regression functions, and the repeatability of surface sampling/ionization methods. Newly developed quantitation strategies in MSI based on aforementioned factors are introduced, including new techniques in standard curve calibration with normalization to an internal standard, kinetic calibration, and chemometric methods. Different strategies for validating q-MSI methods are discussed. Finally, the future perspectives to q-MSI are proposed.
Collapse
Affiliation(s)
- Qian Wu
- College of Chemistry and Chemical Engineering, Central South University, Changsha, Hunan, 410083, P. R. China.
| |
Collapse
|
5
|
Bowman AP, Sawicki J, Talaty NN, Buck WR, Yang J, Wagner DS. Evaluation of Quantitative Platforms for Single Target Mass Spectrometry Imaging. Pharmaceuticals (Basel) 2022; 15:ph15101180. [PMID: 36297291 PMCID: PMC9609477 DOI: 10.3390/ph15101180] [Citation(s) in RCA: 5] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/30/2022] [Revised: 09/19/2022] [Accepted: 09/21/2022] [Indexed: 12/05/2022] Open
Abstract
(1) Imaging of pharmaceutical compounds in tissue is an increasingly important subsection of Mass Spectrometry Imaging (MSI). Identifying proper target engagement requires MS platforms with high sensitivity and spatial resolution. Three prominent categories of drugs are small molecule drugs, antibody-drug conjugate payloads, and protein degraders. (2) We tested six common MSI platforms for their limit of detection (LoD) on a representative compound for each category: a Matrix-Assisted Laser Desorption/Ionization (MALDI) Fourier Transform Ion Cyclotron, a MALDI-2 Time-of-Flight (ToF), a MALDI-2 Trapped Ion Mobility Spectrometry ToF, a Desorption Electrospray Ionization Orbitrap, and 2 Atmospheric Pressure-MALDI Triple Quadrupoles. Samples were homogenized tissue mimetic models of rat liver spiked with known concentrations of analytes. (3) We found that the AP-MALDI-QQQ platform outperformed all 4 competing platforms by a minimum of 2- to 52-fold increase in LoD for representative compounds from each category of pharmaceutical. (4) AP-MALDI-QQQ platforms are effective, cost-efficient mass spectrometers for the identification of targeted analytes of interest.
Collapse
|
6
|
Baquer G, Sementé L, Mahamdi T, Correig X, Ràfols P, García-Altares M. What are we imaging? Software tools and experimental strategies for annotation and identification of small molecules in mass spectrometry imaging. MASS SPECTROMETRY REVIEWS 2022:e21794. [PMID: 35822576 DOI: 10.1002/mas.21794] [Citation(s) in RCA: 8] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Mass spectrometry imaging (MSI) has become a widespread analytical technique to perform nonlabeled spatial molecular identification. The Achilles' heel of MSI is the annotation and identification of molecular species due to intrinsic limitations of the technique (lack of chromatographic separation and the difficulty to apply tandem MS). Successful strategies to perform annotation and identification combine extra analytical steps, like using orthogonal analytical techniques to identify compounds; with algorithms that integrate the spectral and spatial information. In this review, we discuss different experimental strategies and bioinformatics tools to annotate and identify compounds in MSI experiments. We target strategies and tools for small molecule applications, such as lipidomics and metabolomics. First, we explain how sample preparation and the acquisition process influences annotation and identification, from sample preservation to the use of orthogonal techniques. Then, we review twelve software tools for annotation and identification in MSI. Finally, we offer perspectives on two current needs of the MSI community: the adaptation of guidelines for communicating confidence levels in identifications; and the creation of a standard format to store and exchange annotations and identifications in MSI.
Collapse
Affiliation(s)
- Gerard Baquer
- Department of Electronic Engineering, University Rovira I Virgili, Tarragona, Spain
| | - Lluc Sementé
- Department of Electronic Engineering, University Rovira I Virgili, Tarragona, Spain
| | - Toufik Mahamdi
- Department of Electronic Engineering, University Rovira I Virgili, Tarragona, Spain
| | - Xavier Correig
- Department of Electronic Engineering, University Rovira I Virgili, Tarragona, Spain
- Spanish Biomedical Research Center in Diabetes and Associated Metabolic Disorders (CIBERDEM), Madrid, Spain
- Institut D'Investigacio Sanitaria Pere Virgili, Tarragona, Spain
| | - Pere Ràfols
- Department of Electronic Engineering, University Rovira I Virgili, Tarragona, Spain
- Spanish Biomedical Research Center in Diabetes and Associated Metabolic Disorders (CIBERDEM), Madrid, Spain
- Institut D'Investigacio Sanitaria Pere Virgili, Tarragona, Spain
| | - María García-Altares
- Department of Electronic Engineering, University Rovira I Virgili, Tarragona, Spain
- Spanish Biomedical Research Center in Diabetes and Associated Metabolic Disorders (CIBERDEM), Madrid, Spain
| |
Collapse
|
7
|
Dannhorn A, Kazanc E, Hamm G, Swales JG, Strittmatter N, Maglennon G, Goodwin RJA, Takats Z. Correlating Mass Spectrometry Imaging and Liquid Chromatography-Tandem Mass Spectrometry for Tissue-Based Pharmacokinetic Studies. Metabolites 2022; 12:metabo12030261. [PMID: 35323705 PMCID: PMC8954739 DOI: 10.3390/metabo12030261] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/14/2022] [Revised: 03/08/2022] [Accepted: 03/11/2022] [Indexed: 01/12/2023] Open
Abstract
Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a standard tool used for absolute quantification of drugs in pharmacokinetic (PK) studies. However, all spatial information is lost during the extraction and elucidation of a drugs biodistribution within the tissue is impossible. In the study presented here we used a sample embedding protocol optimized for mass spectrometry imaging (MSI) to prepare up to 15 rat intestine specimens at once. Desorption electrospray ionization (DESI) and matrix assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) were employed to determine the distributions and relative abundances of four benchmarking compounds in the intestinal segments. High resolution MALDI-MSI experiments performed at 10 µm spatial resolution allowed to determine the drug distribution in the different intestinal histological compartments to determine the absorbed and tissue bound fractions of the drugs. The low tissue bound drug fractions, which were determined to account for 56–66% of the total drug, highlight the importance to understand the spatial distribution of drugs within the histological compartments of a given tissue to rationalize concentration differences found in PK studies. The mean drug abundances of four benchmark compounds determined by MSI were correlated with the absolute drug concentrations. Linear regression resulted in coefficients of determination (R2) ranging from 0.532 to 0.926 for MALDI-MSI and R2 values ranging from 0.585 to 0.945 for DESI-MSI, validating a quantitative relation of the imaging data. The good correlation of the absolute tissue concentrations of the benchmark compounds and the MSI data provides a bases for relative quantification of compounds within and between tissues, without normalization to an isotopically labelled standard, provided that the compared tissues have inherently similar ion suppression effects.
Collapse
Affiliation(s)
- Andreas Dannhorn
- Department of Metabolism, Digestion and Reproduction, Imperial College London, London SW7 2AZ, UK; (A.D.); (E.K.)
- Imaging & Data Analytics, Clinical Pharmacology and Safety Sciences, R&D, AstraZeneca, Cambridge CB4 0WG, UK; (G.H.); (J.G.S.); (N.S.); (R.J.A.G.)
| | - Emine Kazanc
- Department of Metabolism, Digestion and Reproduction, Imperial College London, London SW7 2AZ, UK; (A.D.); (E.K.)
| | - Gregory Hamm
- Imaging & Data Analytics, Clinical Pharmacology and Safety Sciences, R&D, AstraZeneca, Cambridge CB4 0WG, UK; (G.H.); (J.G.S.); (N.S.); (R.J.A.G.)
| | - John G. Swales
- Imaging & Data Analytics, Clinical Pharmacology and Safety Sciences, R&D, AstraZeneca, Cambridge CB4 0WG, UK; (G.H.); (J.G.S.); (N.S.); (R.J.A.G.)
| | - Nicole Strittmatter
- Imaging & Data Analytics, Clinical Pharmacology and Safety Sciences, R&D, AstraZeneca, Cambridge CB4 0WG, UK; (G.H.); (J.G.S.); (N.S.); (R.J.A.G.)
| | - Gareth Maglennon
- Oncology Safety, Clinical Pharmacology and Safety Sciences, R&D, AstraZeneca, Cambridge CB4 0WG, UK;
| | - Richard J. A. Goodwin
- Imaging & Data Analytics, Clinical Pharmacology and Safety Sciences, R&D, AstraZeneca, Cambridge CB4 0WG, UK; (G.H.); (J.G.S.); (N.S.); (R.J.A.G.)
- Institute of Infection, Immunity and Inflammation, College of Medical, Veterinary and Life Sciences, University of Glasgow, Glasgow G12 8TA, UK
| | - Zoltan Takats
- Department of Metabolism, Digestion and Reproduction, Imperial College London, London SW7 2AZ, UK; (A.D.); (E.K.)
- Laboratoire PRISM, Inserm U1192, University of Lille, Villeneuve d’Ascq, 59655 Lille, France
- The Rosalind Franklin Institute, Harwell OX11 0QG, UK
- Correspondence:
| |
Collapse
|
8
|
Pathmasiri KC, Nguyen TTA, Khamidova N, Cologna SM. Mass spectrometry-based lipid analysis and imaging. CURRENT TOPICS IN MEMBRANES 2021; 88:315-357. [PMID: 34862030 DOI: 10.1016/bs.ctm.2021.10.005] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
Abstract
Mass spectrometry imaging (MSI) is a powerful tool for in situ mapping of analytes across a sample. With growing interest in lipid biochemistry, the ability to perform such mapping without antibodies has opened many opportunities for MSI and lipid analysis. Herein, we discuss the basics of MSI with particular emphasis on MALDI mass spectrometry and lipid analysis. A discussion of critical advancements as well as protocol details are provided to the reader. In addition, strategies for improving the detection of lipids, as well as applications in biomedical research, are presented.
Collapse
Affiliation(s)
- Koralege C Pathmasiri
- Department of Chemistry, University of Illinois at Chicago, Chicago, IL, United States
| | - Thu T A Nguyen
- Department of Chemistry, University of Illinois at Chicago, Chicago, IL, United States
| | - Nigina Khamidova
- Department of Chemistry, University of Illinois at Chicago, Chicago, IL, United States
| | - Stephanie M Cologna
- Department of Chemistry, University of Illinois at Chicago, Chicago, IL, United States; Laboratory of Integrated Neuroscience, University of Illinois at Chicago, Chicago, IL, United States.
| |
Collapse
|
9
|
Kertesz V, Cahill JF. Spatially resolved absolute quantitation in thin tissue by mass spectrometry. Anal Bioanal Chem 2021; 413:2619-2636. [PMID: 33140126 DOI: 10.1007/s00216-020-02964-3] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/11/2022]
Abstract
Mass spectrometry (MS) has become the de facto tool for routine quantitative analysis of biomolecules. MS is increasingly being used to reveal the spatial distribution of proteins, metabolites, and pharmaceuticals in tissue and interest in this area has led to a number of novel spatially resolved MS technologies. Most spatially resolved MS measurements are qualitative in nature due to a myriad of potential biases, such as sample heterogeneity, sampling artifacts, and ionization effects. As applications of spatially resolved MS in the pharmacological and clinical fields increase, demand has become high for quantitative MS imaging and profiling data. As a result, several varied technologies now exist that provide differing levels of spatial and quantitative information. This review provides an overview of MS profiling and imaging technologies that have demonstrated quantitative analysis from tissue. Focus is given on the fundamental processes affecting quantitative analysis in an array of MS imaging and profiling technologies and methods to address these biases.Graphical abstract.
Collapse
Affiliation(s)
- Vilmos Kertesz
- Oak Ridge National Laboratory, Oak Ridge, TN, 37831-6131, USA.
| | - John F Cahill
- Oak Ridge National Laboratory, Oak Ridge, TN, 37831-6131, USA.
| |
Collapse
|
10
|
Quantitative mass spectrometry imaging of drugs and metabolites: a multiplatform comparison. Anal Bioanal Chem 2021; 413:2779-2791. [PMID: 33770207 PMCID: PMC8007509 DOI: 10.1007/s00216-021-03210-0] [Citation(s) in RCA: 24] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/19/2020] [Revised: 01/25/2021] [Accepted: 02/01/2021] [Indexed: 01/11/2023]
Abstract
Mass spectrometry imaging (MSI) provides insight into the molecular distribution of a broad range of compounds and, therefore, is frequently applied in the pharmaceutical industry. Pharmacokinetic and toxicological studies deploy MSI to localize potential drugs and their metabolites in biological tissues but currently require other analytical tools to quantify these pharmaceutical compounds in the same tissues. Quantitative mass spectrometry imaging (Q-MSI) is a field with challenges due to the high biological variability in samples combined with the limited sample cleanup and separation strategies available prior to MSI. In consequence, more selectivity in MSI instruments is required. This can be provided by multiple reaction monitoring (MRM) which uses specific precursor ion-product ion transitions. This targeted approach is in particular suitable for pharmaceutical compounds because their molecular identity is known prior to analysis. In this work, we compared different analytical platforms to assess the performance of MRM detection compared to other MS instruments/MS modes used in a Q-MSI workflow for two drug candidates (A and B). Limit of detection (LOD), linearity, and precision and accuracy of high and low quality control (QC) samples were compared between MS instruments/modes. MRM mode on a triple quadrupole mass spectrometer (QqQ) provided the best overall performance with the following results for compounds A and B: LOD 35.5 and 2.5 μg/g tissue, R2 0.97 and 0.98 linearity, relative standard deviation QC <13.6%, and 97-112% accuracy. Other MS modes resulted in LOD 6.7-569.4 and 2.6-119.1 μg/g tissue, R2 0.86-0.98 and 0.86-0.98 linearity, relative standard deviation QC < 19.4 and < 37.5%, and 70-356% and 64-398% accuracy for drug candidates A and B, respectively. In addition, we propose an optimized 3D printed mimetic tissue model to increase the overall analytical throughput of our approach for large animal studies. The MRM imaging platform was applied as proof-of-principle for quantitative detection of drug candidates A and B in four dog livers and compared to LC-MS. The Q-MSI concentrations differed <3.5 times with the concentrations observed by LC-MS. Our presented MRM-based Q-MSI approach provides a more selective and high-throughput analytical platform due to MRM specificity combined with an optimized 3D printed mimetic tissue model.
Collapse
|
11
|
Applications of stable isotopes in MALDI imaging: current approaches and an eye on the future. Anal Bioanal Chem 2021; 413:2637-2653. [PMID: 33532914 DOI: 10.1007/s00216-021-03189-8] [Citation(s) in RCA: 4] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2020] [Revised: 11/30/2020] [Accepted: 01/20/2021] [Indexed: 02/07/2023]
Abstract
Matrix-assisted laser desorption/ionisation-imaging mass spectrometry (MALDI-IMS) is now an established imaging modality with particular utility in the study of biological, biomedical and pathological processes. In the first instance, the use of stable isotopically labelled (SIL) compounds in MALDI-IMS has addressed technical barriers to increase the accuracy and versatility of this technique. This has undoubtedly enhanced our ability to interpret the two-dimensional ion intensity distributions produced from biological tissue sections. Furthermore, studies using delivery of SIL compounds to live tissues have begun to decipher cell, tissue and inter-tissue metabolism while maintaining spatial resolution. Here, we review both the technical and biological applications of SIL compounds in MALDI-IMS, before using the uptake and metabolism of glucose in bovine ocular lens tissue to illustrate the current limitations of SIL compound use in MALDI-IMS. Finally, we highlight recent instrumentation advances that may further enhance our ability to use SIL compounds in MALDI-IMS to understand biological and pathological processes. Graphical Abstract.
Collapse
|
12
|
Quantitative MALDI mass spectrometry imaging for exploring cutaneous drug delivery of tofacitinib in human skin. Eur J Pharm Biopharm 2020; 159:1-10. [PMID: 33352255 DOI: 10.1016/j.ejpb.2020.12.008] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/28/2020] [Revised: 11/13/2020] [Accepted: 12/11/2020] [Indexed: 12/24/2022]
Abstract
In skin penetration studies, HPLC-MS/MS analysis on extracts of heat-separated epidermis and dermis provides an estimate of the amount of drug penetrated. In this study, MALDI-MSI enabled qualitative skin distribution analysis of endogenous molecules and the drug molecule, tofacitinib and quantitative analysis of the amount of tofacitinib in the epidermis. The delivery of tofacitinib to the skin was investigated in a Franz diffusion cell using three different formulations (two oil-in-water creams, C1 and C2 and an aqueous gel). Further, in vitro release testing (IVRT) was performed and resulted in the fastest release of tofacitinib from the aqueous gel and the lowest from C2. In the ex vivo skin penetration and permeation study, C1 showed the largest skin retention of tofacitinib, whereas, lower retention and higher permeation were observed for the gel and C2. The quantitative MALDI-MSI analysis showed that the content of tofacitinib in the epidermis for the C1 treated samples was comparable to HPLC-MS/MS analysis, whereas, the samples treated with C2 and the aqueous gel were below LOQ. The study demonstrates that MALDI-MSI can be used for the quantitative determination of drug penetration in epidermis, as well as, to provide valuable information on qualitative skin distribution of tofacitinib.
Collapse
|
13
|
Zahraei A, Guo G, Perwick RD, Donaldson PJ, Demarais NJ, Grey AC. Mapping glucose metabolites in the normal bovine lens: Evaluation and optimisation of a matrix-assisted laser desorption/ionisation imaging mass spectrometry method. JOURNAL OF MASS SPECTROMETRY : JMS 2020; 56:e4666. [PMID: 33089566 DOI: 10.1002/jms.4666] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/27/2020] [Revised: 08/02/2020] [Accepted: 09/25/2020] [Indexed: 06/11/2023]
Abstract
The spatial resolution of microdissection-based analytical methods to detect ocular lens glucose uptake, transport and metabolism are poor, whereas the multiplexing capability of fluorescence microscopy-based approaches to simultaneously detect multiple glucose metabolites is limited in comparison with mass spectrometry-based methods. To better understand lens glucose transport and metabolism, a more highly spatially resolved technique that maintains the fragile ocular lens tissue is required. In this study, a sample preparation method for matrix-assisted laser desorption/ionisation imaging mass spectrometry (MALDI IMS) analysis of ocular lens glucose uptake and metabolism has been evaluated and optimised. Matrix choice, tissue preparation and normalisation strategy were determined using negative ion mode MALDI-Fourier transform-ion cyclotron resonance MS of bovine lens tissue and validation performed using gas chromatography-MS. An internal standard was applied concurrently with N-(1-naphthyl)ethylenediamine dihydrochloride (NEDC) matrix to limit cracking of the fresh frozen lens tissue sections. MALDI IMS data were collected at a variety of spatial resolutions to detect both endogenous lens metabolites and stable isotopically labelled glucose introduced by ex vivo lens culture. Using this approach, initial steps in important metabolic processes that are linked to diabetic cataract formation were spatially mapped in the bovine lens. In the future, this method can be applied to study the dynamics of glucose uptake, transport and metabolic flux to aid in the study of diabetic lens cataract pathophysiology.
Collapse
Affiliation(s)
- Ali Zahraei
- School of Medical Sciences, University of Auckland, Auckland, New Zealand
| | - George Guo
- School of Medical Sciences, University of Auckland, Auckland, New Zealand
| | - Rebecca D Perwick
- School of Medical Sciences, University of Auckland, Auckland, New Zealand
| | - Paul J Donaldson
- School of Medical Sciences, University of Auckland, Auckland, New Zealand
| | - Nicholas J Demarais
- School of Biological Sciences, University of Auckland, Auckland, New Zealand
| | - Angus C Grey
- School of Medical Sciences, University of Auckland, Auckland, New Zealand
| |
Collapse
|
14
|
Tobias F, Hummon AB. Considerations for MALDI-Based Quantitative Mass Spectrometry Imaging Studies. J Proteome Res 2020; 19:3620-3630. [PMID: 32786684 DOI: 10.1021/acs.jproteome.0c00443] [Citation(s) in RCA: 42] [Impact Index Per Article: 10.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Significant advances in mass spectrometry imaging (MSI) have pushed the boundaries in obtaining spatial information and quantification in biological samples. Quantitative MSI (qMSI) has typically been challenging to achieve because of matrix and tissue heterogeneity, inefficient analyte extraction, and ion suppression effects, but recent studies have demonstrated approaches to obtain highly robust methods and reproducible results. In this perspective, we share our insights into sample preparation, how the choice of matrix influences sensitivity, construction of calibration curves, signal normalization, and visualization of MSI data. We hope that by articulating these guidelines that qMSI can be routinely conducted while retaining the analytical merits of other mass spectrometry modalities.
Collapse
|
15
|
Validation of MALDI-MS imaging data of selected membrane lipids in murine brain with and without laser postionization by quantitative nano-HPLC-MS using laser microdissection. Anal Bioanal Chem 2020; 412:6875-6886. [PMID: 32712813 PMCID: PMC7496020 DOI: 10.1007/s00216-020-02818-y] [Citation(s) in RCA: 18] [Impact Index Per Article: 4.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/17/2020] [Revised: 06/08/2020] [Accepted: 07/14/2020] [Indexed: 12/23/2022]
Abstract
MALDI mass spectrometry imaging (MALDI-MSI) is a widely used technique to map the spatial distribution of molecules in sectioned tissue. The technique is based on the systematic generation and analysis of ions from small sample volumes, each representing a single pixel of the investigated sample surface. Subsequently, mass spectrometric images for any recorded ion species can be generated by displaying the signal intensity at the coordinate of origin for each of these pixels. Although easily equalized, these recorded signal intensities, however, are not necessarily a good measure for the underlying amount of analyte and care has to be taken in the interpretation of MALDI-MSI data. Physical and chemical properties that define the analyte molecules’ adjacencies in the tissue largely influence the local extraction and ionization efficiencies, possibly leading to strong variations in signal intensity response. Here, we inspect the validity of signal intensity distributions recorded from murine cerebellum as a measure for the underlying molar distributions. Based on segmentation derived from MALDI-MSI measurements, laser microdissection (LMD) was used to cut out regions of interest with a homogenous signal intensity. The molar concentration of six exemplary selected membrane lipids from different lipid classes in these tissue regions was determined using quantitative nano-HPLC-ESI-MS. Comparison of molar concentrations and signal intensity revealed strong deviations between underlying concentration and the distribution suggested by MSI data. Determined signal intensity response factors strongly depend on tissue type and lipid species. Graphical abstract ![]()
Collapse
|
16
|
Gachumi G, Purves RW, Hopf C, El-Aneed A. Fast Quantification Without Conventional Chromatography, The Growing Power of Mass Spectrometry. Anal Chem 2020; 92:8628-8637. [PMID: 32510944 DOI: 10.1021/acs.analchem.0c00877] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/13/2022]
Abstract
Mass spectrometry (MS) in hyphenated techniques is widely accepted as the gold standard quantitative tool in life sciences. However, MS possesses intrinsic analytical capabilities that allow it to be a stand-alone quantitative technique, particularly with current technological advancements. MS has a great potential for simplifying quantitative analysis without the need for tedious chromatographic separation. Its selectivity relies on multistage MS analysis (MSn), including tandem mass spectrometry (MS/MS), as well as the ever-growing advancements of high-resolution MS instruments. This perspective describes various analytical platforms that utilize MS as a stand-alone quantitative technique, namely, flow injection analysis (FIA), matrix assisted laser desorption ionization (MALDI), including MALDI-MS imaging and ion mobility, particularly high-field asymmetric waveform ion mobility spectrometry (FAIMS). When MS alone is not capable of providing reliable quantitative data, instead of conventional liquid chromatography (LC)-MS, the use of a guard column (i.e., fast chromatography) may be sufficient for quantification. Although the omission of chromatographic separation simplifies the analytical process, extra procedures may be needed during sample preparation and clean-up to address the issue of matrix effects. The discussion of this manuscript focuses on key parameters underlying the uniqueness of each technique for its application in quantitative analysis without the need for a chromatographic separation. In addition, the potential for each analytical strategy and its challenges are discussed as well as improvements needed to render them as mainstream quantitative analytical tools. Overcoming the hurdles for fully validating a quantitative method will allow MS alone to eventually become an indispensable quantitative tool for clinical and toxicological studies.
Collapse
Affiliation(s)
- George Gachumi
- College of Pharmacy and Nutrition, University of Saskatchewan, 107 Wiggins Road, Saskatoon, Saskatchewan Canada, S7N 5E5
| | - Randy W Purves
- College of Pharmacy and Nutrition, University of Saskatchewan, 107 Wiggins Road, Saskatoon, Saskatchewan Canada, S7N 5E5.,Centre for Veterinary Drug Residues, Canadian Food Inspection Agency, 116 Veterinary Rd, Saskatoon, Saskatchewan Canada, S7N 2R3
| | - Carsten Hopf
- Center for Mass Spectrometry and Optical Spectroscopy (CeMOS), Mannheim University of Applied Sciences, Paul-Wittsack-Strasse 10, 68163 Mannheim, Germany
| | - Anas El-Aneed
- College of Pharmacy and Nutrition, University of Saskatchewan, 107 Wiggins Road, Saskatoon, Saskatchewan Canada, S7N 5E5
| |
Collapse
|
17
|
Sugiyama E, Skelly AN, Suematsu M, Sugiura Y. In situ imaging of monoamine localization and dynamics. Pharmacol Ther 2020; 208:107478. [DOI: 10.1016/j.pharmthera.2020.107478] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/16/2018] [Accepted: 11/22/2019] [Indexed: 01/06/2023]
|
18
|
Bagley MC, Stepanova AN, Ekelöf M, Alonso JM, Muddiman DC. Development of a relative quantification method for infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging of Arabidopsis seedlings. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2020; 34:e8616. [PMID: 31658400 DOI: 10.1002/rcm.8616] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2019] [Revised: 09/15/2019] [Accepted: 09/30/2019] [Indexed: 06/10/2023]
Abstract
RATIONALE Mass spectrometry imaging of young seedlings is an invaluable tool in understanding how mutations affect metabolite accumulation in plant development. However, due to numerous biological considerations, established methods for the relative quantification of analytes using infrared matrix-assisted laser desorption electrospray ionization (IR-MALDESI) mass spectrometry imaging are not viable options. In this study, we report a method for the quantification of auxin-related compounds using stable-isotope-labelled (SIL) indole-3-acetic acid (IAA) doped into agarose substrate. METHODS Wild-type Arabidopsis thaliana seedlings, sur2 and wei8 tar2 loss-of-function mutants, and YUC1 gain-of-function line were grown for 3 days in the dark in standard growth medium. SIL-IAA was doped into a 1% low-melting-point agarose gel and seedlings were gently laid on top for IR-MALDESI imaging with Orbitrap mass spectrometry analysis. Relative quantification was performed post-acquisition by normalization of auxin-related compounds to SIL-IAA in the agarose. Amounts of auxin-related compounds were compared between genotypes to distinguish the effects of the mutations on the accumulation of indolic metabolites of interest. RESULTS IAA added to agarose was found to remain stable, with repeatability and abundance features of IAA comparable with those of other compounds used in other methods for relative quantification in IR-MALDESI analyses. Indole-3-acetaldoxime was increased in sur2 mutants compared with wild-type and other mutants. Other auxin-related metabolites were either below the limits of quantification or successfully quantified but showing little difference among mutants. CONCLUSIONS Agarose was shown to be an appropriate sampling surface for IR-MALDESI mass spectrometry imaging of Arabidopsis seedlings. SIL-IAA doping of agarose was demonstrated as a viable technique for relative quantification of metabolites in live seedlings or tissues with similar biological considerations.
Collapse
Affiliation(s)
- M Caleb Bagley
- Department of Chemistry, FTMS Laboratory for Human Health Research, North Carolina State University, Raleigh, NC, 27695, USA
| | - Anna N Stepanova
- Department of Plant and Microbial Biology, North Carolina State University, Raleigh, NC, 27695, USA
- Program in Genetics, North Carolina State University, Raleigh, NC, 27695, USA
| | - Måns Ekelöf
- Department of Chemistry, FTMS Laboratory for Human Health Research, North Carolina State University, Raleigh, NC, 27695, USA
| | - Jose M Alonso
- Department of Plant and Microbial Biology, North Carolina State University, Raleigh, NC, 27695, USA
- Program in Genetics, North Carolina State University, Raleigh, NC, 27695, USA
| | - David C Muddiman
- Department of Chemistry, FTMS Laboratory for Human Health Research, North Carolina State University, Raleigh, NC, 27695, USA
- Department of Plant and Microbial Biology, North Carolina State University, Raleigh, NC, 27695, USA
- Molecular Education, Technology, and Research Innovation Center (METRIC), North Carolina State University, Raleigh, NC, 27695, USA
| |
Collapse
|
19
|
Rubio VY, Cagmat JG, Wang GP, Yost RA, Garrett TJ. Analysis of Tryptophan Metabolites in Serum Using Wide-Isolation Strategies for UHPLC-HRMS/MS. Anal Chem 2020; 92:2550-2557. [PMID: 31927994 DOI: 10.1021/acs.analchem.9b04210] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/08/2023]
Abstract
Current targeted metabolomic workflows are limited by design and thus sacrifice crucial information from a profiling standpoint that could lead to a more fundamental understanding of the metabolic processes of interest. One drawback to performing targeted analysis on ion trapping instruments is the potential for increased variability in analysis when analytes and standards are isolated and trapped individually for fragmentation. In addition, this sequential isolation process increases the duty cycle of the mass spectrometer and reduces the number of points collected across a chromatographic peak. To address this, the use of a wide-isolation window (12 Da) to encompass the target analyte and the isotope standard within a single fragmentation window ensures that fragmentation is consistent when quantitation relies on the ratio of the target to the internal standard. Additionally, the preservation of a faster scan rate ensures that optimal representation of chromatographic peaks is preserved for the purposes of both quantitative and qualitative analyses that require peak integration for statistical analysis. The use of this flexible method is promising in the investigation of pathways that require multiple targets and are highly integrated within the system. Here, we demonstrate the application of this method in a fast ultra-high performance liquid chromatography (UHPLC) analysis to integrate wide-isolation quantitative strategies for high-resolution mass spectrometry (HRMS) combined with profiling qualitative metabolomics for the analysis of tryptophan degradation metabolites in mouse serum. Analysis of tryptophan-deficient states as compared to control in both germ-free or E. coli gut microbiota states was used to quantitate pathway-specific metabolites as well as obtain full profiling information. The quantitative and qualitative results revealed the preservation of the primary pathways of degradation in the kynurenine pathway to potentially produce primary products such as nicotinamide during stress-induced dietary states.
Collapse
Affiliation(s)
- Vanessa Y Rubio
- Department of Chemistry , University of Florida , Gainesville , Florida 32610 , United States
| | - Joy G Cagmat
- Southeast Center for Integrated Metabolomics , University of Florida , Gainesville , Florida 32611 , United States
| | - Gary P Wang
- Department of Medicine, Division of Infectious Diseases and Global Medicine , University of Florida , Gainesville , Florida 32610 , United States
| | - Richard A Yost
- Department of Chemistry , University of Florida , Gainesville , Florida 32610 , United States.,Southeast Center for Integrated Metabolomics , University of Florida , Gainesville , Florida 32611 , United States.,Department of Pathology, Immunology, and Laboratory Medicine , University of Florida , Gainesville , Florida 32610 , United States
| | - Timothy J Garrett
- Southeast Center for Integrated Metabolomics , University of Florida , Gainesville , Florida 32611 , United States.,Department of Pathology, Immunology, and Laboratory Medicine , University of Florida , Gainesville , Florida 32610 , United States
| |
Collapse
|
20
|
Quantification and assessment of detection capability in imaging mass spectrometry using a revised mimetic tissue model. Bioanalysis 2019; 11:1099-1116. [PMID: 31251106 DOI: 10.4155/bio-2019-0035] [Citation(s) in RCA: 35] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/17/2022] Open
Abstract
Aim: A revised method of preparing the mimetic tissue model for quantitative imaging mass spectrometry (IMS) is evaluated. Concepts of assessing detection capability are adapted from other imaging or mass spectrometry (MS)-based technologies to improve upon the reliability of IMS quantification. Materials & methods: The mimetic tissue model is prepared by serially freezing spiked-tissue homogenates into a cylindrical mold to create a plug of tissue with a stepped concentration gradient of matrix-matched standards. Weighted least squares (WLS) linear regression is applied due to the heteroscedastisity (change in variance with intensity) of most MS data. Results & conclusions: Imaging poses several caveats for quantification which are unique compared with other MS-based methods. Aspects of the design, construction, application, and evaluation of the matrix-matched standard curve for the mimetic tissue model are discussed. In addition, the criticality of the ion distribution in the design of a purposeful liquid chromatography coupled to mass spectrometry (LC-MS) validation is reviewed.
Collapse
|
21
|
Nozaki K, Nakabayashi Y, Murakami T, Miyazato A, Osaka I. Novel approach to enhance sensitivity in surface-assisted laser desorption/ionization mass spectrometry imaging using deposited organic-inorganic hybrid matrices. JOURNAL OF MASS SPECTROMETRY : JMS 2019; 54:612-619. [PMID: 31070274 DOI: 10.1002/jms.4370] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/29/2019] [Revised: 04/16/2019] [Accepted: 05/02/2019] [Indexed: 06/09/2023]
Abstract
Sample pretreatment is key to obtaining good data in matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI). Although sublimation is one of the best methods for obtaining homogenously fine organic matrix crystals, its sensitivity can be low due to the lack of a solvent extraction effect. We investigated the effect of incorporating a thin film of metal formed by zirconium (Zr) sputtering into the sublimation process for MALDI matrix deposition for improving the detection sensitivity in mouse liver tissue sections treated with olanzapine. The matrix-enhanced surface-assisted laser desorption/ionization (ME-SALDI) method, where a matrix was formed by sputtering Zr to form a thin nanoparticle layer before depositing MALDI organic matrix comprising α-cyano-4-hydroxycinnamic acid (CHCA) by sublimation, resulted in a significant improvement in sensitivity, with the ion intensity of olanzapine being about 1800 times that observed using the MALDI method, comprising CHCA sublimation alone. When Zr sputtering was performed after CHCA deposition, however, no such enhancement in sensitivity was observed. The enhanced sensitivity due to Zr sputtering was also observed when the CHCA solution was applied by spraying, being about twice as high as that observed by CHCA spraying alone. In addition, the detection sensitivity of these various pretreatment methods was similar for endogenous glutathione. Given that sample preparation using the ME-SALDI-MSI method, which combines Zr sputtering with the sublimation method for depositing an organic matrix, does not involve a solvent, delocalization problems such as migration of analytes observed after matrix spraying and washing with aqueous solutions as sample pretreatment are not expected. Therefore, ME-Zr-SALDI-MSI is a novel sample pretreatment method that can improve the sensitivity of analytes while maintaining high spatial resolution in MALDI-MSI.
Collapse
Affiliation(s)
- Kazuyoshi Nozaki
- Bioimaging, Analysis & Pharmacokinetics Research Labs. Drug Discovery research, Astellas Pharma Inc, 21 Miyukigaoka, Tsukuba-shi, Ibaraki, 305-8585, Japan
| | - Yuji Nakabayashi
- Center for Nano Material and Technology, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi, Ishikawa, 923-1292, Japan
| | - Tatsuya Murakami
- Center for Nano Material and Technology, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi, Ishikawa, 923-1292, Japan
| | - Akio Miyazato
- Center for Nano Material and Technology, Japan Advanced Institute of Science and Technology, 1-1 Asahidai, Nomi, Ishikawa, 923-1292, Japan
| | - Issey Osaka
- Department of Pharmaceutical Engineering, Faculty of Engineering, Toyama Prefectural University, 5180 Kurokawa, Imizu-City, Toyama, 939-0398, Japan
| |
Collapse
|
22
|
Song X, He J, Li C, Sun C, Pang X, Zhang J, Zang Q, Luo Z, Li X, Zhang R, Abliz Z. Fabrication of homogenous three-dimensional biomimetic tissue for mass spectrometry imaging. JOURNAL OF MASS SPECTROMETRY : JMS 2019; 54:378-388. [PMID: 30742348 DOI: 10.1002/jms.4342] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/04/2018] [Revised: 01/26/2019] [Accepted: 02/06/2019] [Indexed: 06/09/2023]
Abstract
Reference samples are essential for mass spectrometric method optimization, data quality control, and target analyte quantitation. However, it is highly challenging to prepare an ideal homogeneous, standard-spiked tissue sample for mass spectrometry imaging (MSI) research. Herein, we present a standard-spiked 3D biomimetic tissue model fabricated with native cells, homogenate matrix, and biocompatible polymer. Unlike traditional homogenized tissue surrogates or those constructed with "on-tissue" or "under-tissue" micropipetting strategies, this simulated tissue shares both structural integrity of cells and homogeneous properties of matrix. As a result, analyte standards could undergo more in-depth incorporation and has a more comparable native status with a real tissue. Series of tissue sections made from the 3D tissue model were proven to be feasible and useful for the parameter optimization, analyte quantitation, and calibration curve fitting for the air-flow assisted desorption electrospray ionization MSI. Additionally, by analyzing the quality control model sections, we proposed a median principal component score calibration and demonstrated that this method can normalize instrumental fluctuations to stable levels in a large-scale untargeted MSI experiments for the reliable metabolomic biomarker discovery. Thus, these results indicated that the standard-spiked 3D biomimetic tissue has convincing significance in MSI analysis.
Collapse
Affiliation(s)
- Xiaowei Song
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100050, China
| | - Jiuming He
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100050, China
| | - Chao Li
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100050, China
| | - Chenglong Sun
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100050, China
| | - Xuechao Pang
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100050, China
| | - Jin Zhang
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100050, China
| | - Qingce Zang
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100050, China
| | - Zhigang Luo
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100050, China
| | - Xin Li
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100050, China
| | - Ruiping Zhang
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100050, China
| | - Zeper Abliz
- State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, 100050, China
- Centre for Imaging and Systems Biology, School of Pharmacy, Minzu University of China, Beijing, 100081, China
| |
Collapse
|
23
|
Schulz S, Becker M, Groseclose MR, Schadt S, Hopf C. Advanced MALDI mass spectrometry imaging in pharmaceutical research and drug development. Curr Opin Biotechnol 2019; 55:51-59. [DOI: 10.1016/j.copbio.2018.08.003] [Citation(s) in RCA: 115] [Impact Index Per Article: 23.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/06/2018] [Revised: 07/21/2018] [Accepted: 08/03/2018] [Indexed: 12/20/2022]
|
24
|
Tang W, Chen J, Zhou J, Ge J, Zhang Y, Li P, Li B. Quantitative MALDI Imaging of Spatial Distributions and Dynamic Changes of Tetrandrine in Multiple Organs of Rats. Am J Cancer Res 2019; 9:932-944. [PMID: 30867807 PMCID: PMC6401406 DOI: 10.7150/thno.30408] [Citation(s) in RCA: 46] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2018] [Accepted: 12/22/2018] [Indexed: 12/16/2022] Open
Abstract
Detailed spatio-temporal information on drug distribution in organs is of paramount importance to assess drug clinically-relevant properties and potential side-effects. Matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI MSI) as a label-free and sensitive imaging modality provides an additional means of accurately visualizing drug and its metabolites distributions in tissue sections. However, technical limitations, complex physiochemical environment of surface and low abundance of target drugs make quantitative MALDI imaging of drug and its metabolites quite challenging. Methods: In this study, an internal standard correction strategy was applied for quantitative MALDI imaging of tetrandrine in multiple organs of rats including lung, liver, kidney, spleen, and heart. The feasibility and reliability of the developed quantitative MSI method were validated by conventional liquid chromatography-tandem MS (LC-MS/MS) analysis, and the two methods showed a significant correlation. Results: The quantitative MALDI imaging method met the requirements of specificity, sensitivity and linearity. Tissue-specific spatio-temporal distribution patterns of tetrandrine in different organs were revealed after intravenous administration in the rat. Moreover, demethylated metabolite was detected in liver tissues. Conclusions: The current work illustrates that quantitative MALDI imaging provides an alternative means of accurately addressing the problem of drug and its metabolites distribution in tissues, complementary to traditional LC-MS/MS of tissue homogenates and whole-body autoradiography (WBA). Quantitative spatio-chemical information obtained here can improve our understanding of pharmacokinetics (PK), pharmacodynamics (PD), and potential transient toxicities of tetrandrine in organs, and possibly direct further optimization of drug properties to reduce drug-induced organ toxicity.
Collapse
|
25
|
Maganti RJ, Hronowski XL, Dunstan RW, Wipke BT, Zhang X, Jandreski L, Hamann S, Juhasz P. Defining Changes in the Spatial Distribution and Composition of Brain Lipids in the Shiverer and Cuprizone Mouse Models of Myelin Disease. J Histochem Cytochem 2018; 67:203-219. [PMID: 30501365 PMCID: PMC6393840 DOI: 10.1369/0022155418815860] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/22/2022] Open
Abstract
Myelin is composed primarily of lipids and diseases affecting myelin are associated with alterations in its lipid composition. However, correlation of the spatial (in situ) distribution of lipids with the disease-associated compositional and morphological changes is not well defined. Herein we applied high resolution matrix-assisted laser desorption ionization imaging mass spectrometry (MALDI-IMS), immunohistochemistry (IHC), and liquid chromatography–electrospray ionization–mass spectrometry (LC-ESI-MS) to evaluate brain lipid alterations in the dysmyelinating shiverer (Shi) mouse and cuprizone (Cz) mouse model of reversible demyelination. MALDI-IMS revealed a decrease in the spatial distribution of sulfatide (SHexCer) species, SHexCer (d42:2), and a phosphatidylcholine (PC) species, PC (36:1), in white matter regions like corpus callosum (CC) both in the Shi mouse and Cz mouse model. Changes in these lipid species were restored albeit not entirely upon spontaneous remyelination after demyelination in the Cz mouse model. Lipid distribution changes correlated with the local morphological changes as confirmed by IHC. LC-ESI-MS analyses of CC extracts confirmed the MALDI-IMS derived reductions in SHexCer and PC species. These findings highlight the role of SHexCer and PC in preserving the normal myelin architecture and our experimental approaches provide a morphological basis to define lipid abnormalities relevant to myelin diseases.
Collapse
Affiliation(s)
| | | | - Robert W Dunstan
- Biogen, Cambridge, Massachusetts.,AbbVie, Worcester, Massachusetts
| | | | | | | | | | | |
Collapse
|
26
|
Morineau L, Jacobsen SC, Kleberg K, Hansen HS, Janfelt C. Delivery of amitriptyline by intravenous and intraperitoneal administration compared in the same animal by whole-body mass spectrometry imaging of a stable isotope labelled drug substance in mice. Expert Opin Drug Deliv 2018; 15:1157-1163. [PMID: 30359150 DOI: 10.1080/17425247.2018.1541084] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/28/2022]
Abstract
BACKGROUND The distribution and metabolism of a drug in the organism are dependent on the administration route as well as on the drug formulation. It is important to be able to assess which impact the administration route or formulation of a drug has for its distribution and metabolism. METHODS The antidepressant drug amitriptyline was intravenously (IV) dosed to a mouse and immediately after, a similar amount of a deuterium-labeled version of the drug was intraperitoneally (IP) dosed to the same animal. Whole-body cryo-sections were made at t = 5, 15, 30, and 60 min post-dosing, and the two drug substances and metabolites were imaged by DESI-MS/MS. RESULTS After 5 min, the IV dosed drug was detected throughout the animal, while the IP dosed drug was primarily found in the abdominal cavity. At later times, the differences between the two administration routes became less pronounced. Two administration routes provided highly similar metabolite distributions, also at early time points. CONCLUSION The method provides a unique way to compare delivery and metabolism of a drug by different administration routes or formulations in the very same animal, eliminating uncertainties caused by animal-to-animal variation and avoiding the use of radioactive labeling.
Collapse
Affiliation(s)
- Loïs Morineau
- a UFR Sciences et Techniques , Université de Nantes , Nantes , France
| | - Sophie Chakroun Jacobsen
- b Department of Pharmacy, Faculty of Health and Medical Sciences , University of Copenhagen , Copenhagen , Denmark
| | - Karen Kleberg
- c Department of Drug Design and Pharmacology, Faculty of Health and Medical Sciences , University of Copenhagen , Copenhagen , Denmark
| | - Harald S Hansen
- c Department of Drug Design and Pharmacology, Faculty of Health and Medical Sciences , University of Copenhagen , Copenhagen , Denmark
| | - Christian Janfelt
- b Department of Pharmacy, Faculty of Health and Medical Sciences , University of Copenhagen , Copenhagen , Denmark
| |
Collapse
|
27
|
Taylor AJ, Dexter A, Bunch J. Exploring Ion Suppression in Mass Spectrometry Imaging of a Heterogeneous Tissue. Anal Chem 2018; 90:5637-5645. [PMID: 29461803 DOI: 10.1021/acs.analchem.7b05005] [Citation(s) in RCA: 87] [Impact Index Per Article: 14.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/24/2022]
Abstract
In this study we have explored several aspects of regional analyte suppression in mass spectrometry imaging (MSI) of a heterogeneous sample, transverse cryosections of mouse brain. Olanzapine was homogeneously coated across the section prior to desorption electrospray ionization (DESI) and matrix-assisted laser desorption ionization (MALDI) mass spectrometry imaging. We employed the concept of a tissue extinction coefficient (TEC) to assess suppression of an analyte on tissue relative to its intensity in an off tissue region. We expanded the use of TEC, by first segmenting anatomical regions using graph-cuts clustering and calculating a TEC for each cluster. The single ion image of the olanzapine [M + H]+ ion was seen to vary considerably across the image, with anatomical features such as the white matter and hippocampus visible. While trends in regional ion suppression were conserved across MSI modalities, significant changes in the magnitude of relative regional suppression effects between techniques were seen. Notably the intensity of olanzapine was less suppressed in DESI than for MALDI. In MALDI MSI, significant differences in the concentration dependence of regional TECs were seen, with the TEC of white matter clusters exhibiting a notably stronger correlation with concentration than for clusters associated with gray matter regions. We further employed cluster-specific TECs as regional normalization factors. In comparison to published pixel-by-pixel normalization methods, regional TEC normalization exhibited superior reduction ion suppression artifacts. We also considered the usefulness of a segmentation-based approach to compare spectral information obtained from complementary modalities.
Collapse
Affiliation(s)
- Adam J Taylor
- National Centre of Excellence in Mass Spectrometry Imaging (NiCE-MSI) , National Physical Laboratory , Hampton Road , Teddington , TW11 0LW , U.K
| | - Alex Dexter
- National Centre of Excellence in Mass Spectrometry Imaging (NiCE-MSI) , National Physical Laboratory , Hampton Road , Teddington , TW11 0LW , U.K
| | - Josephine Bunch
- National Centre of Excellence in Mass Spectrometry Imaging (NiCE-MSI) , National Physical Laboratory , Hampton Road , Teddington , TW11 0LW , U.K.,Department of Surgery and Cancer , Imperial College London , South Kensington Campus, London , SW7 2AZ , U.K
| |
Collapse
|
28
|
Lefcoski S, Kew K, Reece S, Torres MJ, Parks J, Reece S, de Castro Brás LE, Virag JAI. Anatomical-Molecular Distribution of EphrinA1 in Infarcted Mouse Heart Using MALDI Mass Spectrometry Imaging. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2018; 29:527-534. [PMID: 29305797 PMCID: PMC5838209 DOI: 10.1007/s13361-017-1869-7] [Citation(s) in RCA: 11] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/03/2017] [Revised: 10/04/2017] [Accepted: 12/16/2017] [Indexed: 05/11/2023]
Abstract
EphrinA1 is a tyrosine kinase receptor localized in the cellular membrane of healthy cardiomyocytes, the expression of which is lost upon myocardial infarction (MI). Intra-cardiac injection of the recombinant form of ephrinA1 (ephrinA1-Fc) at the time of ligation in mice has shown beneficial effects by reducing infarct size and myocardial necrosis post-MI. To date, immunohistochemistry and Western blotting comprise the only experimental approaches utilized to localize and quantify relative changes of ephrinA1 in sections and homogenates of whole left ventricle, respectively. Herein, we used matrix-assisted laser desorption ionization mass spectrometry imaging (MALDI-MSI) coupled with a time-of-flight mass spectrometer (MALDI/TOF MS) to identify intact as well as tryptic fragments of ephrinA1 in healthy controls and acutely infarcted murine hearts. The purpose of the present study was 3-fold: (1) to spatially resolve the molecular distribution of endogenous ephrinA1, (2) to determine the anatomical expression profile of endogenous ephrinA1 after acute MI, and (3) to identify molecular targets of ephrinA1-Fc action post-MI. The tryptic fragments detected were identified as the ephrinA1-isoform with 38% and 34% sequence coverage and Mascot scores of 25 for the control and MI hearts, respectively. By using MALDI-MSI, we have been able to simultaneously measure the distribution and spatial localization of ephrinA1, as well as additional cardiac proteins, thus offering valuable information for the elucidation of molecular partners, mediators, and targets of ephrinA1 action in cardiac muscle. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Stephan Lefcoski
- Department of Physiology, Brody School of Medicine, East Carolina University, Greenville, NC, 27834, USA
| | - Kimberly Kew
- Department of Chemistry, East Carolina University, Greenville, NC, 27834, USA
| | - Shaun Reece
- Department of Physiology, Brody School of Medicine, East Carolina University, Greenville, NC, 27834, USA
| | - Maria J Torres
- East Carolina Diabetes and Obesity Institute, East Carolina University, Greenville, NC, 27834, USA
| | - Justin Parks
- Department of Physiology, Brody School of Medicine, East Carolina University, Greenville, NC, 27834, USA
| | - Sky Reece
- Department of Physiology, Brody School of Medicine, East Carolina University, Greenville, NC, 27834, USA
| | - Lisandra E de Castro Brás
- Department of Physiology, Brody School of Medicine, East Carolina University, Greenville, NC, 27834, USA
| | - Jitka A I Virag
- Department of Physiology, Brody School of Medicine, East Carolina University, Greenville, NC, 27834, USA.
| |
Collapse
|
29
|
Abstract
Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI-IMS) is a histological method used for various molecules including gangliosides. The method is based on mass spectrometry, and thus target molecules with small structural differences are directly and independently detected. Here we describe a general procedure and related key notes for analyzing major brain gangliosides by MALDI-IMS.
Collapse
Affiliation(s)
- Eiji Sugiyama
- Department of Biochemistry, Keio University School of Medicine, Tokyo, Japan
| | - Mitsutoshi Setou
- International Mass Imaging Center and Department of Cellular and Molecular Anatomy, Hamamatsu University School of Medicine, Shizuoka, Japan.
| |
Collapse
|
30
|
Aboulmagd S, Esteban-Fernández D, Moreno-Gordaliza E, Neumann B, El-Khatib AH, Lázaro A, Tejedor A, Gómez-Gómez MM, Linscheid MW. Dual Internal Standards with Metals and Molecules for MALDI Imaging of Kidney Lipids. Anal Chem 2017; 89:12727-12734. [DOI: 10.1021/acs.analchem.7b02819] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Affiliation(s)
- Sarah Aboulmagd
- Department
of Chemistry, Humboldt-Universität zu Berlin, Brook-Taylor Strasse 2, 12489 Berlin, Germany
| | - Diego Esteban-Fernández
- Department
of Chemistry, Humboldt-Universität zu Berlin, Brook-Taylor Strasse 2, 12489 Berlin, Germany
| | - Estefanía Moreno-Gordaliza
- Department
of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, Avda. Complutense s/n, 28040, Madrid, Spain
| | - Boris Neumann
- Proteome Factory, Magnusstraße 11, 12489 Berlin, Germany
- Charité-Universitätmedizin Berlin, Institute of Pharmacology, Hessische Straße 3-4, 10115 Berlin, Germany
| | - A. H. El-Khatib
- Department
of Chemistry, Humboldt-Universität zu Berlin, Brook-Taylor Strasse 2, 12489 Berlin, Germany
- Pharmaceutical
Analytical Chemistry Department, Faculty of Pharmacy, Ain Shams University, 11566 Cairo, Egypt
| | - Alberto Lázaro
- Renal Pathophysiology
Laboratory, Department of Nephrology, Instituto de Investigación
Sanitaria Gregorio Marañón, Hospital General Universitario Gregorio Marañón, C/Dr. Esquerdo 46, 28007, Madrid, Spain
| | - Alberto Tejedor
- Renal Pathophysiology
Laboratory, Department of Nephrology, Instituto de Investigación
Sanitaria Gregorio Marañón, Hospital General Universitario Gregorio Marañón, C/Dr. Esquerdo 46, 28007, Madrid, Spain
| | - M. Milagros Gómez-Gómez
- Department
of Analytical Chemistry, Faculty of Chemistry, Universidad Complutense de Madrid, Avda. Complutense s/n, 28040, Madrid, Spain
| | - Michael W. Linscheid
- Department
of Chemistry, Humboldt-Universität zu Berlin, Brook-Taylor Strasse 2, 12489 Berlin, Germany
| |
Collapse
|
31
|
Abstract
Here, we describe a method for obtaining whole-body MALDI imaging data. MALDI imaging provides chemical compound-specific information not attainable with conventional histology techniques. The specificity of mass spectrometry with the addition of spatial information makes this a very powerful technique, especially for the analysis of endogenous and exogenous small molecules. This chapter will provide the reader with a comprehensive description of the techniques involved in obtaining high-quality MALDI mass spectrometry imaging (MSI) data from large tissue sections.
Collapse
|
32
|
Prentice BM, Chumbley CW, Caprioli RM. Absolute Quantification of Rifampicin by MALDI Imaging Mass Spectrometry Using Multiple TOF/TOF Events in a Single Laser Shot. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2017; 28:136-144. [PMID: 27655354 PMCID: PMC5177505 DOI: 10.1007/s13361-016-1501-2] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/10/2016] [Revised: 08/31/2016] [Accepted: 09/02/2016] [Indexed: 05/13/2023]
Abstract
Matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) allows for the visualization of molecular distributions within tissue sections. While providing excellent molecular specificity and spatial information, absolute quantification by MALDI IMS remains challenging. Especially in the low molecular weight region of the spectrum, analysis is complicated by matrix interferences and ionization suppression. Though tandem mass spectrometry (MS/MS) can be used to ensure chemical specificity and improve sensitivity by eliminating chemical noise, typical MALDI MS/MS modalities only scan for a single MS/MS event per laser shot. Herein, we describe TOF/TOF instrumentation that enables multiple fragmentation events to be performed in a single laser shot, allowing the intensity of the analyte to be referenced to the intensity of the internal standard in each laser shot while maintaining the benefits of MS/MS. This approach is illustrated by the quantitative analyses of rifampicin (RIF), an antibiotic used to treat tuberculosis, in pooled human plasma using rifapentine (RPT) as an internal standard. The results show greater than 4-fold improvements in relative standard deviation as well as improved coefficients of determination (R2) and accuracy (>93% quality controls, <9% relative errors). This technology is used as an imaging modality to measure absolute RIF concentrations in liver tissue from an animal dosed in vivo. Each microspot in the quantitative image measures the local RIF concentration in the tissue section, providing absolute pixel-to-pixel quantification from different tissue microenvironments. The average concentration determined by IMS is in agreement with the concentration determined by HPLC-MS/MS, showing a percent difference of 10.6%. Graphical Abstract ᅟ.
Collapse
Affiliation(s)
- Boone M Prentice
- Department of Biochemistry, Vanderbilt University, 9160 MRB III, Nashville, TN, 37232, USA
- Mass Spectrometry Research Center, Nashville, TN, 37232, USA
| | - Chad W Chumbley
- Department of Chemistry, Nashville, TN, 37232, USA
- Mass Spectrometry Research Center, Nashville, TN, 37232, USA
| | - Richard M Caprioli
- Department of Biochemistry, Vanderbilt University, 9160 MRB III, Nashville, TN, 37232, USA.
- Department of Chemistry, Nashville, TN, 37232, USA.
- Departments of Pharmacology and Medicine, Nashville, TN, 37232, USA.
- Mass Spectrometry Research Center, Nashville, TN, 37232, USA.
| |
Collapse
|
33
|
Rzagalinski I, Volmer DA. Quantification of low molecular weight compounds by MALDI imaging mass spectrometry - A tutorial review. BIOCHIMICA ET BIOPHYSICA ACTA-PROTEINS AND PROTEOMICS 2016; 1865:726-739. [PMID: 28012871 DOI: 10.1016/j.bbapap.2016.12.011] [Citation(s) in RCA: 65] [Impact Index Per Article: 8.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2016] [Revised: 12/01/2016] [Accepted: 12/19/2016] [Indexed: 10/20/2022]
Abstract
Matrix-assisted laser desorption/ionization (MALDI)-mass spectrometry imaging (MSI) permits label-free in situ analysis of chemical compounds directly from the surface of two-dimensional biological tissue slices. It links qualitative molecular information of compounds to their spatial coordinates and distribution within the investigated tissue. MALDI-MSI can also provide the quantitative amounts of target compounds in the tissue, if proper calibration techniques are performed. Obviously, as the target molecules are embedded within the biological tissue environment and analysis must be performed at their precise locations, there is no possibility for extensive sample clean-up routines or chromatographic separations as usually performed with homogenized biological materials; ion suppression phenomena therefore become a critical side effect of MALDI-MSI. Absolute quantification by MALDI-MSI should provide an accurate value of the concentration/amount of the compound of interest in relatively small, well-defined region of interest of the examined tissue, ideally in a single pixel. This goal is extremely challenging and will not only depend on the technical possibilities and limitations of the MSI instrument hardware, but equally on the chosen calibration/standardization strategy. These strategies are the main focus of this article and are discussed and contrasted in detail in this tutorial review. This article is part of a Special Issue entitled: MALDI Imaging, edited by Dr. Corinna Henkel and Prof. Peter Hoffmann.
Collapse
Affiliation(s)
- Ignacy Rzagalinski
- Institute of Bioanalytical Chemistry, Saarland University, 66123 Saarbrücken, Germany
| | - Dietrich A Volmer
- Institute of Bioanalytical Chemistry, Saarland University, 66123 Saarbrücken, Germany.
| |
Collapse
|
34
|
Chandler J, Haslam C, Hardy N, Leveridge M, Marshall P. A Systematic Investigation of the Best Buffers for Use in Screening by MALDI-Mass Spectrometry. SLAS DISCOVERY 2016; 22:1262-1269. [PMID: 27932699 DOI: 10.1177/1087057116681726] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 11/15/2022]
Abstract
Matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) offers a label-free alternative for the screening of biochemical targets in both 1536- and 6144-assay formats, as well as potentially providing increased sensitivity, reproducibility, and the simultaneous detection of multiple assay components within a specified m/z range. Ion suppression effects are one of the principal limitations reported for MS analysis. Within MALDI-MS screening, it has been identified that certain biochemical components incorporated into the assay (e.g., the buffers used to preserve the physiological conditions of the enzyme, salts, and other additives) induce suppression of the analyte ion signals monitored. This poorly understood phenomenon of ion suppression is a key reason the screening community has been reluctant to shift their investigations toward MS methods with reduced sample cleanup. Using acetylcholine as an assay substrate mimic, we have generated robust data to quantify the degree to which the most highly used components (base buffers, additional components, detergents, cell culture media, and other additives) within current screening assays are compatible with MALDI-MS. Here, the most suitable buffers and components, along with their identified optimal concentrations in terms of limiting ion suppression effects, are proposed for use in screening assays measured by MALDI-MS.
Collapse
Affiliation(s)
- Jessica Chandler
- 1 Platform Technology and Science, GlaxoSmithKline, Stevenage, UK
| | - Carl Haslam
- 1 Platform Technology and Science, GlaxoSmithKline, Stevenage, UK
| | - Neil Hardy
- 1 Platform Technology and Science, GlaxoSmithKline, Stevenage, UK
| | | | - Peter Marshall
- 1 Platform Technology and Science, GlaxoSmithKline, Stevenage, UK
| |
Collapse
|
35
|
Spatial Quantitation of Drugs in tissues using Liquid Extraction Surface Analysis Mass Spectrometry Imaging. Sci Rep 2016; 6:37648. [PMID: 27883030 PMCID: PMC5121636 DOI: 10.1038/srep37648] [Citation(s) in RCA: 42] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/30/2016] [Accepted: 10/28/2016] [Indexed: 12/17/2022] Open
Abstract
Liquid extraction surface analysis mass spectrometry imaging (LESA-MSI) has been shown to be an effective tissue profiling and imaging technique, producing robust and reliable qualitative distribution images of an analyte or analytes in tissue sections. Here, we expand the use of LESA-MSI beyond qualitative analysis to a quantitative analytical technique by employing a mimetic tissue model previously shown to be applicable for MALDI-MSI quantitation. Liver homogenate was used to generate a viable and molecularly relevant control matrix for spiked drug standards which can be frozen, sectioned and subsequently analyzed for the generation of calibration curves to quantify unknown tissue section samples. The effects of extraction solvent composition, tissue thickness and solvent/tissue contact time were explored prior to any quantitative studies in order to optimize the LESA-MSI method across several different chemical entities. The use of a internal standard to normalize regional differences in ionization response across tissue sections was also investigated. Data are presented comparing quantitative results generated by LESA-MSI to LC-MS/MS. Subsequent analysis of adjacent tissue sections using DESI-MSI is also reported.
Collapse
|
36
|
Hansen HT, Janfelt C. Aspects of Quantitation in Mass Spectrometry Imaging Investigated on Cryo-Sections of Spiked Tissue Homogenates. Anal Chem 2016; 88:11513-11520. [PMID: 27934123 DOI: 10.1021/acs.analchem.6b02711] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Internal standards have been introduced in quantitative mass spectrometry imaging in order to compensate for differences in intensities throughout an image caused by, for example, difference in ion suppression or analyte extraction efficiency. To test how well the internal standards compensate for differences in tissue types in, for example, whole-body imaging, a set of tissue homogenates of different tissue types (lung, liver, kidney, heart, and brain) from rabbit was spiked to the same concentration with the drug amitriptyline and imaged in the same experiment using isotope labeled amitriptyline as internal standard. The results showed, even after correction with internal standard, significantly lower intensities from brain and to some extent also lung tissue, differences which may be ascribed to binding of the drug to proteins or lipids as known from traditional bioanalysis. The differences, which for these results range approximately within a factor of 3 (but for other compounds in other tissues could be higher), underscore the importance of preparing the standard curve in the same matrix as the unknown sample whenever possible. In, for example, whole-body imaging where a diversity of tissue types are present, this variation across tissue types will therefore add to the overall uncertainty in quantitation. The tissue homogenates were also used in a characterization of various phenomena in quantitative MSI, such as to study how the signal depends of the thickness of the cryo-section, and to assess the accuracy of calibration by droplet deposition. For experiments on liver tissue, calibration by spiked tissue homogenates and droplet deposition was found to provide highly similar results and in both cases linearity with R2 values of 0.99. In the process, a new method was developed for preparation of standard curves of spiked tissue homogenates, based on the drilling of holes in a block of frozen liver homogenate, providing easy cryo-slicing and good quantitative performance.
Collapse
Affiliation(s)
- Heidi Toft Hansen
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen , Universitetsparken 2, 2100 Copenhagen, Denmark
| | - Christian Janfelt
- Department of Pharmacy, Faculty of Health and Medical Sciences, University of Copenhagen , Universitetsparken 2, 2100 Copenhagen, Denmark
| |
Collapse
|
37
|
Kiss A, Hopfgartner G. Laser-based methods for the analysis of low molecular weight compounds in biological matrices. Methods 2016; 104:142-53. [DOI: 10.1016/j.ymeth.2016.04.017] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/30/2015] [Revised: 02/28/2016] [Accepted: 04/13/2016] [Indexed: 01/26/2023] Open
|
38
|
Potential of MALDI imaging for the toxicological evaluation of environmental pollutants. J Proteomics 2016; 144:133-9. [PMID: 27178109 DOI: 10.1016/j.jprot.2016.05.008] [Citation(s) in RCA: 24] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2016] [Revised: 04/13/2016] [Accepted: 05/08/2016] [Indexed: 01/02/2023]
Abstract
Risk assessment related to the exposure of humans to chemicals released into the environment is a major concern of our modern societies. In this context, toxicology plays a crucial role to characterize the effects of this exposure on health and identify the targets of these molecules. MALDI imaging mass spectrometry (IMS) is an enabling technology for biodistribution studies of chemicals. Although the majority of published studies are presented in a pharmacological context, the concepts discussed in this review can be applied to the toxicological evaluation of chemicals released into the environment. The major asset of IMS is the simultaneous localization and identification of a parent molecule and its metabolites without labeling and without any prior knowledge. Quantification methods developed in IMS are presented with application to an environmental pollutant. IMS is effective in the localization of chemicals and endogenous species. This opens unique perspectives for the discovery of molecular alterations in metabolites and protein biomarkers that could help for a better understanding of toxicity mechanisms. Distribution studies of agrochemicals in plants by IMS can contribute to a better understanding of their mode of action and to a more effective use of these chemicals, avoiding the current concern of environmental damage.
Collapse
|
39
|
Källback P, Nilsson A, Shariatgorji M, Andrén PE. msIQuant--Quantitation Software for Mass Spectrometry Imaging Enabling Fast Access, Visualization, and Analysis of Large Data Sets. Anal Chem 2016; 88:4346-53. [PMID: 27014927 DOI: 10.1021/acs.analchem.5b04603] [Citation(s) in RCA: 90] [Impact Index Per Article: 11.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/24/2023]
Abstract
This paper presents msIQuant, a novel instrument- and manufacturer-independent quantitative mass spectrometry imaging software suite that uses the standardized open access data format imzML. Its data processing structure enables rapid image display and the analysis of very large data sets (>50 GB) without any data reduction. In addition, msIQuant provides many tools for image visualization including multiple interpolation methods, low intensity transparency display, and image fusion. It also has a quantitation function that automatically generates calibration standard curves from series of standards that can be used to determine the concentrations of specific analytes. Regions-of-interest in a tissue section can be analyzed based on a number of quantities including the number of pixels, average intensity, standard deviation of intensity, and median and quartile intensities. Moreover, the suite's export functions enable simplified postprocessing of data and report creation. We demonstrate its potential through several applications including the quantitation of small molecules such as drugs and neurotransmitters. The msIQuant suite is a powerful tool for accessing and evaluating very large data sets, quantifying drugs and endogenous compounds in tissue areas of interest, and for processing mass spectra and images.
Collapse
Affiliation(s)
- Patrik Källback
- Biomolecular Imaging and Proteomics, National Resource for Mass Spectrometry Imaging, Department of Pharmaceutical Biosciences, Uppsala University , Box 591, SE-75124 Uppsala, Sweden
| | - Anna Nilsson
- Biomolecular Imaging and Proteomics, National Resource for Mass Spectrometry Imaging, Department of Pharmaceutical Biosciences, Uppsala University , Box 591, SE-75124 Uppsala, Sweden
| | - Mohammadreza Shariatgorji
- Biomolecular Imaging and Proteomics, National Resource for Mass Spectrometry Imaging, Department of Pharmaceutical Biosciences, Uppsala University , Box 591, SE-75124 Uppsala, Sweden
| | - Per E Andrén
- Biomolecular Imaging and Proteomics, National Resource for Mass Spectrometry Imaging, Department of Pharmaceutical Biosciences, Uppsala University , Box 591, SE-75124 Uppsala, Sweden
| |
Collapse
|
40
|
Dong Y, Guella G, Franceschi P. Impact of tissue surface properties on the desorption electrospray ionization imaging of organic acids in grapevine stem. RAPID COMMUNICATIONS IN MASS SPECTROMETRY : RCM 2016; 30:711-718. [PMID: 26864524 DOI: 10.1002/rcm.7495] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/30/2015] [Revised: 12/10/2015] [Accepted: 12/20/2015] [Indexed: 06/05/2023]
Abstract
RATIONALE Desorption electrospray ionization (DESI) imaging is a fast analytical technique used to assess spatially resolved biological processes over unmodified sample surfaces. Although DESI profiling experiments have demonstrated that the properties of the sample surface significantly affect the outcomes of DESI analyses, the potential implications of these phenomena in imaging applications have not yet been explored extensively. METHODS The distribution of endogenous and exogenous organic acids in pith and out pith region of grapevine stems was investigated by using DESI imaging, ion chromatography and direct infusion methods. Several common normalization strategies to account for the surface effect, including TIC normalization, addition of the internal standard in the spray solvent and deposition of the standard over the sample surface, were critically evaluated. RESULTS DESI imaging results show that, in our case, the measured distributions of these small organic acids are not consistent with their 'true' localizations within the tissues. Furthermore, our results indicate that the common normalization strategies are not able to completely compensate for the observed surface effect. CONCLUSIONS Variations in the tissue surface properties across the tissue sample can greatly affect the semi-quantitative detection of organic acids. Attention should be paid when interpreting DESI imaging results and an independent analytical validation step is important in untargeted DESI imaging investigations.
Collapse
Affiliation(s)
- Yonghui Dong
- Biostatistics and Data Management, Research and Innovation Centre - Fondazione Edmund Mach, S. Michele all'Adige, (TN), Italy
| | - Graziano Guella
- Bioorganic Chemistry Laboratory, Department of Physics, University of Trento, Povo, (TN), Italy
| | - Pietro Franceschi
- Biostatistics and Data Management, Research and Innovation Centre - Fondazione Edmund Mach, S. Michele all'Adige, (TN), Italy
| |
Collapse
|
41
|
Chumbley CW, Reyzer ML, Allen JL, Marriner GA, Via LE, Barry CE, Caprioli RM. Absolute Quantitative MALDI Imaging Mass Spectrometry: A Case of Rifampicin in Liver Tissues. Anal Chem 2016; 88:2392-8. [PMID: 26814665 DOI: 10.1021/acs.analchem.5b04409] [Citation(s) in RCA: 124] [Impact Index Per Article: 15.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Abstract
Matrix-assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS) elucidates molecular distributions in thin tissue sections. Absolute pixel-to-pixel quantitation has remained a challenge, primarily lacking validation of the appropriate analytical methods. In the present work, isotopically labeled internal standards are applied to tissue sections to maximize quantitative reproducibility and yield accurate quantitative results. We have developed a tissue model for rifampicin (RIF), an antibiotic used to treat tuberculosis, and have tested different methods of applying an isotopically labeled internal standard for MALDI IMS analysis. The application of the standard and subsequently the matrix onto tissue sections resulted in quantitation that was not statistically significantly different from results obtained using HPLC-MS/MS of tissue extracts. Quantitative IMS experiments were performed on liver tissue from an animal dosed in vivo. Each microspot in the quantitative images measures the local concentration of RIF in the thin tissue section. Lower concentrations were detected from the blood vessels and around the portal tracts. The quantitative values obtained from these measurements were comparable (>90% similarity) to HPLC-MS/MS results obtained from extracts of the same tissue.
Collapse
Affiliation(s)
- Chad W Chumbley
- Department of Chemistry, Vanderbilt University , Nashville, Tennessee 37235, United States
| | - Michelle L Reyzer
- Mass Spectrometry Research Center, Vanderbilt University , Nashville, Tennessee 37240, United States
| | - Jamie L Allen
- Mass Spectrometry Research Center, Vanderbilt University , Nashville, Tennessee 37240, United States
| | - Gwendolyn A Marriner
- Tuberculosis Research Section, Laboratory of Clinical Infectious Diseases, National Institute of Allergy and Infectious Diseases, National Institutes of Health , Bethesda, Maryland 20892, United States
| | - Laura E Via
- Tuberculosis Research Section, Laboratory of Clinical Infectious Diseases, National Institute of Allergy and Infectious Diseases, National Institutes of Health , Bethesda, Maryland 20892, United States.,Institute of Infectious Disease and Molecular Medicine, Department of Clinical Laboratory Sciences, University of Cape Town , Cape Town, South Africa
| | - Clifton E Barry
- Tuberculosis Research Section, Laboratory of Clinical Infectious Diseases, National Institute of Allergy and Infectious Diseases, National Institutes of Health , Bethesda, Maryland 20892, United States.,Institute of Infectious Disease and Molecular Medicine, Department of Clinical Laboratory Sciences, University of Cape Town , Cape Town, South Africa
| | - Richard M Caprioli
- Department of Chemistry, Vanderbilt University , Nashville, Tennessee 37235, United States.,Mass Spectrometry Research Center, Vanderbilt University , Nashville, Tennessee 37240, United States.,Departments of Pharmacology, Biochemistry, and Medicine, Vanderbilt University , 465 21st Avenue South, Medical Research Building III, Nashville, Tennessee 37240, United States
| |
Collapse
|
42
|
Li B, Dunham SJ, Dong Y, Yoon S, Zeng M, Sweedler JV. Analytical capabilities of mass spectrometry imaging and its potential applications in food science. Trends Food Sci Technol 2016. [DOI: 10.1016/j.tifs.2015.10.018] [Citation(s) in RCA: 26] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/19/2023]
|
43
|
Pharmacokinetic and pharmacometabolomic study of pirfenidone in normal mouse tissues using high mass resolution MALDI-FTICR-mass spectrometry imaging. Histochem Cell Biol 2015; 145:201-11. [PMID: 26645566 DOI: 10.1007/s00418-015-1382-7] [Citation(s) in RCA: 29] [Impact Index Per Article: 3.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Accepted: 10/26/2015] [Indexed: 10/22/2022]
Abstract
Given the importance of pirfenidone as the first worldwide-approved drug for idiopathic pulmonary fibrosis treatment, its pharmacodynamic properties and the metabolic response to pirfenidone treatment have not been fully elucidated. The aim of the present study was to get molecular insights of pirfenidone-related pharmacometabolomic response using MALDI-FTICR-MSI. Quantitative MALDI-FTICR-MSI was carried out for determining the pharmacokinetic properties of pirfenidone and its related metabolites 5-hydroxymethyl pirfenidone and 5-carboxy pirfenidone in lung, liver and kidney. To monitor the effect of pirfenidone administration on endogenous cell metabolism, additional in situ endogenous metabolite imaging was performed in lung tissue sections. While pirfenidone is highly abundant and delocalized across the whole micro-regions of lung, kidney and liver, 5-hydroxymethyl pirfenidone and 5-carboxy pirfenidone demonstrate heterogeneous distribution patterns in lung and kidney. In situ endogenous metabolite imaging study of lung tissue indicates no significant effects of pirfenidone on metabolic pathways. Remarkably, we found 129 discriminative m/z values which represent clear differences between control and treated lungs, the majority of which are currently unknown. PCA analysis and heatmap view can accurately distinguish control and treated groups. This is the first pharmacokinetic study to investigate the tissue distribution of orally administered pirfenidone and its related metabolites simultaneously in organs without labeling. The combination of pharmametabolome with histological features provides detailed mapping of drug effects on metabolism as response of healthy lung tissue to pirfenidone treatment.
Collapse
|
44
|
Sugiyama E, Masaki N, Matsushita S, Setou M. Ammonium Sulfate Improves Detection of Hydrophilic Quaternary Ammonium Compounds through Decreased Ion Suppression in Matrix-Assisted Laser Desorption/Ionization Imaging Mass Spectrometry. Anal Chem 2015; 87:11176-81. [DOI: 10.1021/acs.analchem.5b02672] [Citation(s) in RCA: 24] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/21/2023]
Affiliation(s)
- Eiji Sugiyama
- Department
of Cell Biology
and Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku Hamamatsu, Shizuoka, 431-3192, Japan
| | - Noritaka Masaki
- Department
of Cell Biology
and Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku Hamamatsu, Shizuoka, 431-3192, Japan
| | - Shoko Matsushita
- Department
of Cell Biology
and Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku Hamamatsu, Shizuoka, 431-3192, Japan
| | - Mitsutoshi Setou
- Department
of Cell Biology
and Anatomy, Hamamatsu University School of Medicine, 1-20-1 Handayama, Higashi-ku Hamamatsu, Shizuoka, 431-3192, Japan
| |
Collapse
|
45
|
Abstract
This article highlights recent advancements in the quantitative measurement of drug distribution by MS imaging (MSI). Quantitation by MSI was recently considering the primary disadvantage of MSI approaches particularly when compared with widely used autoradiography techniques. These approaches show significant progress in the area of quantitative MSI and have been used in numerous drug and metabolite distribution measurements. As quantitative limitations are overcome, the use of MSI in drug development should increase significantly providing key insights into both tissue-target validation as well as identifying off tissue-target issues with drug delivery.
Collapse
|
46
|
Prideaux B, ElNaggar MS, Zimmerman M, Wiseman JM, Li X, Dartois V. Mass spectrometry imaging of levofloxacin distribution in TB-infected pulmonary lesions by MALDI-MSI and continuous liquid microjunction surface sampling. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY 2015; 377:699-708. [PMID: 26185484 PMCID: PMC4501920 DOI: 10.1016/j.ijms.2014.08.024] [Citation(s) in RCA: 51] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/08/2023]
Abstract
A multi-modal mass spectrometry imaging (MSI) and profiling approach has been applied to assess the partitioning of the anti-TB fluoroquinolone levofloxacin into pulmonary lesions. Matrix-assisted laser desorption ionization mass spectrometry imaging (MALDI-MSI) and a commercial liquid microjunction surface sampling technology (LMJ-SSP), or flowprobe, have been used to both spatially profile and image drug distributions in lung tissue sections from TB-infected rabbits following oral administration of a single human-equivalent dose. Levofloxacin levels were highest at 6 h post-dose in normal lung, cellular granuloma, and necrotic caseum compartments. The drug accumulated in the cellular granuloma regions with lower amounts partitioning into central caseous compartments. Flowprobe imaging at 630 μm (limited by the probe tip diameter) enabled visualization of drug distribution into lesion compartments, including limited differentiation of relative drug abundance in cellular versus caseous regions of the lesions. MALDI-MSI analysis at 75 μm provided more detailed drug distribution, which clearly accumulated in the cellular region immediately surrounding the central caseum core. Imaging and profiling data acquired by flowprobe and MALDI-MSI were validated by quantitative LC/MS/MS analysis of lung and granuloma homogenates taken from the same animals. The results of the investigation show flowprobe imaging and sampling as a rapid and sensitive alternative to MALDI-MSI for profiling drug distributions into tissues when spatial resolution of data below the threshold of the probe diameter is not required.
Collapse
Affiliation(s)
- Brendan Prideaux
- Public Health Research Institute, New Jersey Medical School, Rutgers, Newark, NJ 07103, USA
- Corresponding author. Tel.: +1 2012818025; fax: +1 9738543160. (B. Prideaux)
| | | | - Matthew Zimmerman
- Public Health Research Institute, New Jersey Medical School, Rutgers, Newark, NJ 07103, USA
| | | | - Xiaohua Li
- Public Health Research Institute, New Jersey Medical School, Rutgers, Newark, NJ 07103, USA
| | - Véronique Dartois
- Public Health Research Institute, New Jersey Medical School, Rutgers, Newark, NJ 07103, USA
| |
Collapse
|
47
|
Barceló-Coblijn G, Fernández JA. Mass spectrometry coupled to imaging techniques: the better the view the greater the challenge. Front Physiol 2015; 6:3. [PMID: 25657625 PMCID: PMC4302787 DOI: 10.3389/fphys.2015.00003] [Citation(s) in RCA: 10] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/28/2014] [Accepted: 01/06/2015] [Indexed: 11/13/2022] Open
Abstract
These are definitively exciting times for membrane lipid researchers. Once considered just as the cell membrane building blocks, the important role these lipids play is steadily being acknowledged. The improvement occurred in mass spectrometry techniques (MS) allows the establishment of the precise lipid composition of biological extracts. However, to fully understand the biological function of each individual lipid species, we need to know its spatial distribution and dynamics. In the past 10 years, the field has experienced a profound revolution thanks to the development of MS-based techniques allowing lipid imaging (MSI). Images reveal and verify what many lipid researchers had already shown by different means, but none as convincing as an image: each cell type presents a specific lipid composition, which is highly sensitive to its physiological and pathological state. While these techniques will help to place membrane lipids in the position they deserve, they also open the black box containing all the unknown regulatory mechanisms accounting for such tailored lipid composition. Thus, these results urges to different disciplines to redefine their paradigm of study by including the complexity revealed by the MSI techniques.
Collapse
Affiliation(s)
- Gwendolyn Barceló-Coblijn
- Lipids in Human Pathology, Research Unit, Hospital Universitari Son Espases, Institut d'Investigació Sanitària de Palma (IdISPa) Palma, Spain
| | - José A Fernández
- Departamento de Química-Física, Facultad de Ciencia y Tecnología, Universidad del País Vasco (UPV/EHU) Leioa, Spain
| |
Collapse
|
48
|
Nilsson A, Goodwin RJA, Shariatgorji M, Vallianatou T, Webborn PJH, Andrén PE. Mass Spectrometry Imaging in Drug Development. Anal Chem 2015; 87:1437-55. [DOI: 10.1021/ac504734s] [Citation(s) in RCA: 133] [Impact Index Per Article: 14.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/06/2023]
Affiliation(s)
- Anna Nilsson
- Biomolecular
Imaging and Proteomics, National Center for Mass Spectrometry Imaging,
Department of Pharmaceutical Biosciences, Uppsala University, P.O. Box 591 BMC, 75124 Uppsala, Sweden
| | - Richard J. A. Goodwin
- Drug Safety & Metabolism, Innovative Medicines, AstraZeneca, Darwin Building 310, Cambridge Science Park, Milton Road, Cambridge, Cambridgeshire CB4 OWG, U.K
| | - Mohammadreza Shariatgorji
- Biomolecular
Imaging and Proteomics, National Center for Mass Spectrometry Imaging,
Department of Pharmaceutical Biosciences, Uppsala University, P.O. Box 591 BMC, 75124 Uppsala, Sweden
| | - Theodosia Vallianatou
- Biomolecular
Imaging and Proteomics, National Center for Mass Spectrometry Imaging,
Department of Pharmaceutical Biosciences, Uppsala University, P.O. Box 591 BMC, 75124 Uppsala, Sweden
| | - Peter J. H. Webborn
- Drug Safety & Metabolism, Innovative Medicines, AstraZeneca, Darwin Building 310, Cambridge Science Park, Milton Road, Cambridge, Cambridgeshire CB4 OWG, U.K
| | - Per E. Andrén
- Biomolecular
Imaging and Proteomics, National Center for Mass Spectrometry Imaging,
Department of Pharmaceutical Biosciences, Uppsala University, P.O. Box 591 BMC, 75124 Uppsala, Sweden
| |
Collapse
|
49
|
Wang B, Dearring CL, Wager-Miller J, Mackie K, Trimpin S. Drug detection and quantification directly from tissue using novel ionization methods for mass spectrometry. EUROPEAN JOURNAL OF MASS SPECTROMETRY (CHICHESTER, ENGLAND) 2015; 21:201-10. [PMID: 26307700 PMCID: PMC4762651 DOI: 10.1255/ejms.1338] [Citation(s) in RCA: 6] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/14/2023]
Abstract
Solvent assisted ionization inlet (SAII) and matrix assisted ionization vacuum (MAIV) were used to quantify rapidly an antipsychotic drug, clozapine, directly from surfaces with minimal sample preparation. This simple surface analysis method based on SAII- and MAIV-mass spectrometry (MS) was developed to allow the detection of endogenous lipids, metabolites, and clozapine directly from sections of mouse brain tissue. A rapid surface assessment was achieved by SAII with the assistance of heat applied to the mass spectrometer inlet. MAIV provided an improved reproducibility without the need of a heated inlet. In addition, isotope dilution and standard addition were used without sample clean-up, and the results correlate well with liquid chromatography tandem MS using sample work-up. Using the simple surface methods, standard solutions containing clozapine and a deuterated internal standard (clozapine-d8) at different concentration ratios were used in the extraction and quantification of clozapine from brain tissue sections of a drug-treated mouse using different tissue thicknesses. The amount of clozapine extracted by these surface methods was independent of tissue thickness.
Collapse
Affiliation(s)
- Beixi Wang
- Department of Chemistry, Wayne State University, Detroit, MI 48202.
| | | | - James Wager-Miller
- Department of Psychological & Brain Sciences, Indiana University, Bloomington, IN 47405.
| | - Ken Mackie
- Department of Psychological & Brain Sciences, Indiana University, Bloomington, IN 47405.
| | - Sarah Trimpin
- Department of Chemistry, Wayne State University, Detroit, MI 48202. Cardiovascular Research Institute, Wayne State University School of Medicine, Detroit, MI 48201.
| |
Collapse
|
50
|
Porta T, Lesur A, Varesio E, Hopfgartner G. Quantification in MALDI-MS imaging: what can we learn from MALDI-selected reaction monitoring and what can we expect for imaging? Anal Bioanal Chem 2014; 407:2177-87. [PMID: 25486918 DOI: 10.1007/s00216-014-8315-5] [Citation(s) in RCA: 76] [Impact Index Per Article: 7.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/05/2014] [Revised: 10/29/2014] [Accepted: 11/03/2014] [Indexed: 12/12/2022]
Abstract
Quantification by mass spectrometry imaging (Q-MSI) is one of the hottest topics of the current discussions among the experts of the MS imaging community. If MSI is established as a powerful qualitative tool in drug and biomarker discovery, its reliability for absolute and accurate quantification (QUAN) is still controversial. Indeed, Q-MSI has to deal with several fundamental aspects that are difficult to control, and to account for absolute quantification. The first objective of this manuscript is to review the state-of-the-art of Q-MSI and the current strategies developed for absolute quantification by direct surface sampling from tissue sections. This includes comments on the quest for the perfect matrix-matched standards and signal normalization approaches. Furthermore, this work investigates quantification at a pixel level to determine how many pixels must be considered for accurate quantification by ultraviolet matrix-assisted laser desorption/ionization (MALDI), the most widely used technique for MSI. Particularly, this study focuses on the MALDI-selected reaction monitoring (SRM) in rastering mode, previously demonstrated as a quantitative and robust approach for small analyte and peptide-targeted analyses. The importance of designing experiments of good quality and the use of a labeled compound for signal normalization is emphasized to minimize the signal variability. This is exemplified by measuring the signal for cocaine and a tryptic peptide (i.e., obtained after digestion of a monoclonal antibody) upon different experimental conditions, such as sample stage velocity, laser power and frequency, or distance between two raster lines. Our findings show that accurate quantification cannot be performed on a single pixel but requires averaging of at least 4-5 pixels. The present work demonstrates that MALDI-SRM/MSI is quantitative with precision better than 10-15 %, which meets the requirements of most guidelines (i.e., in bioanalysis or toxicology) for quantification of drugs or peptides from tissue homogenates.
Collapse
Affiliation(s)
- Tiffany Porta
- Life Sciences Mass Spectrometry, School of Pharmaceutical Sciences, University of Geneva, University of Lausanne, Quai Ernest-Ansermet 30, 1211, Geneva 4, Switzerland
| | | | | | | |
Collapse
|