1
|
Silveri F, Della Pelle F, Scroccarello A, Ain Bukhari QU, Del Carlo M, Compagnone D. Modular graphene mediator film-based electrochemical pocket device for chlorpyrifos determination. Talanta 2022; 240:123212. [PMID: 35026635 DOI: 10.1016/j.talanta.2022.123212] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/17/2021] [Revised: 12/01/2021] [Accepted: 01/04/2022] [Indexed: 12/12/2022]
Abstract
In this work, a redox-graphene (Rx-Gr) film with electron-mediating ability has been integrated into a modular flexible pocket device, giving rise to a reusable biosensing platform. The Rx-Gr has been obtained in water from graphite taking advantage of catechin, a redox-antioxidant, able to assist the sonochemical layered-material exfoliation, conferring electron mediating feature. A film composed exclusively of Rx-Gr has been transferred via thermal rolling onto a flexible PET-support that was used as the biosensor base. The biosensing platform, composed of office-grade materials, was then fabricated using a cutter-plotter and assembled by thermal lamination; an interchangeable paper-based strip was used to host the enzymatic reaction and drive the capillary flow. An acetylcholinesterase-based inhibition assay has been optimized onboard the pocket device to determine chlorpyriphos, a widespread environmental pesticide. The proposed set-up allows the determination of chlorpyriphos at low overpotential (0.2 V) with satisfactory sensitivity (LOD = 0.2 ppb), thanks to the straightforward electroactivity of the Rx-Gr film towards thiocholine (enzymatic product). The modular design allows 5 consecutive complete inhibition assays (control + inhibition measure) retaining the performance (RSD = 5.4%; n = 5). The coupling of bench-top technologies and a new functional graphene film resulted in the development of a cost-effective, reusable, transportable, and within everyone's reach biosensing platform.
Collapse
Affiliation(s)
- Filippo Silveri
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100, Teramo, Italy
| | - Flavio Della Pelle
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100, Teramo, Italy.
| | - Annalisa Scroccarello
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100, Teramo, Italy
| | - Qurat Ul Ain Bukhari
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100, Teramo, Italy
| | - Michele Del Carlo
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100, Teramo, Italy
| | - Dario Compagnone
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100, Teramo, Italy.
| |
Collapse
|
2
|
Lu N, Kutter JP. Recent advances in microchip enantioseparation and analysis. Electrophoresis 2020; 41:2122-2135. [PMID: 32949465 DOI: 10.1002/elps.202000242] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/17/2020] [Revised: 09/10/2020] [Accepted: 09/16/2020] [Indexed: 12/26/2022]
Abstract
This review summarizes recent developments (over the past decade) in the field of microfluidics-based solutions for enantiomeric separation and detection. The progress in various formats of microchip electrodriven separations, such as MCE, microchip electrochromatography, and multidimensional separation techniques, is discussed. Innovations covering chiral stationary phases, surface coatings, and modification strategies to improve resolution, as well as integration with detection systems, are reported. Finally, combinations with other microfluidic functional units are also presented and highlighted.
Collapse
Affiliation(s)
- Nan Lu
- Department of Pharmacy, University of Copenhagen, Copenhagen, Denmark
| | - Jörg P Kutter
- Department of Pharmacy, University of Copenhagen, Copenhagen, Denmark
| |
Collapse
|
3
|
Hernández-Rodríguez JF, Della Pelle F, Rojas D, Compagnone D, Escarpa A. Xurography-Enabled Thermally Transferred Carbon Nanomaterial-Based Electrochemical Sensors on Polyethylene Terephthalate-Ethylene Vinyl Acetate Films. Anal Chem 2020; 92:13565-13572. [PMID: 32869640 DOI: 10.1021/acs.analchem.0c03240] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
A novel benchtop approach to fabricate xurography-enabled thermally transferred (XTT) carbon nanomaterial-based electrochemical sensors is proposed. Filtered nanomaterial (NM) films were transferred from Teflon filters to polyethylene terephthalate-ethylene vinyl acetate (PET-EVA) substrates by a temperature-driven approach. Customized PET-EVA components were xurographically patterned by a cutting plotter. The smart design of PET-EVA films enabled us to selectively transfer the nanomaterial to the exposed EVA side of the substrate. Hence, the substrate played an active role in selectively controlling where nanomaterial transfer occurred allowing us to design different working electrode geometries. Counter and reference electrodes were integrated by a stencil-printing approach, and the whole device was assembled by thermal lamination. To prove the versatility of the technology, XTT materials were exclusively made of carbon black (XTT-CB), multiwalled carbon nanotubes (XTT-MWCNTs), and single-walled carbon nanotubes (XTT-SWCNTs). Their electrochemical behavior was carefully studied and was found to be highly dependent on the amount and type of NM employed. XTT-SWCNTs were demonstrated to be the best-performing sensors, and they were employed for the determination of l-tyrosine (l-Tyr) in human plasma from tyrosinemia-diagnosed patients. High analytical performance toward l-Tyr (linear range of 0.5-100 μM, LOD = 0.1 μM), interelectrode precision (RSD ip,a = 3%, n = 10; RSD calibration slope = 4%, n = 3), and accurate l-Tyr quantification in plasma samples with low relative errors (≤7%) compared to the clinical declared values were obtained. The proposed benchtop approach is cost-effective and straightforward, does not require sophisticated facilities, and can be potentially employed to develop pure or hybrid nanomaterial-based electrodes.
Collapse
Affiliation(s)
- Juan F Hernández-Rodríguez
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain
| | - Flavio Della Pelle
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain.,Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100 Teramo, Italy
| | - Daniel Rojas
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain.,Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100 Teramo, Italy
| | - Dario Compagnone
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, Campus "Aurelio Saliceti" via R. Balzarini 1, 64100 Teramo, Italy
| | - Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Sciences, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain.,Chemical Research Institute Andres M. del Rio, University of Alcalá, E-28871 Alcalá de Henares, Madrid, Spain
| |
Collapse
|
4
|
Nanomaterial-based electrochemical (bio)-sensing: One step ahead in diagnostic and monitoring of metabolic rare diseases. Trends Analyt Chem 2019. [DOI: 10.1016/j.trac.2019.05.020] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
|
5
|
Wongkaew N, Simsek M, Griesche C, Baeumner AJ. Functional Nanomaterials and Nanostructures Enhancing Electrochemical Biosensors and Lab-on-a-Chip Performances: Recent Progress, Applications, and Future Perspective. Chem Rev 2018; 119:120-194. [DOI: 10.1021/acs.chemrev.8b00172] [Citation(s) in RCA: 303] [Impact Index Per Article: 43.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Affiliation(s)
- Nongnoot Wongkaew
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Marcel Simsek
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Christian Griesche
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| | - Antje J. Baeumner
- Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, 93053 Regensburg, Germany
| |
Collapse
|
6
|
Manzanares Palenzuela CL, Novotný F, Krupička P, Sofer Z, Pumera M. 3D-Printed Graphene/Polylactic Acid Electrodes Promise High Sensitivity in Electroanalysis. Anal Chem 2018; 90:5753-5757. [PMID: 29658700 DOI: 10.1021/acs.analchem.8b00083] [Citation(s) in RCA: 113] [Impact Index Per Article: 16.1] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/25/2022]
Abstract
Additive manufacturing provides a unique tool for prototyping structures toward electrochemical sensing, due to its ability to produce highly versatile, tailored-shaped devices in a low-cost and fast way with minimized waste. Here we present 3D-printed graphene electrodes for electrochemical sensing. Ring- and disc-shaped electrodes were 3D-printed with a Fused Deposition Modeling printer and characterized using cyclic voltammetry and scanning electron microscopy. Different redox probes K3Fe(CN)6:K4Fe(CN)6, FeCl3, ascorbic acid, Ru(NH3)6Cl3, and ferrocene monocarboxylic acid) were used to assess the electrochemical performance of these devices. Finally, the electrochemical detection of picric acid and ascorbic acid was carried out as proof-of-concept analytes for sensing applications. Such customizable platforms represent promising alternatives to conventional electrodes for a wide range of sensing applications.
Collapse
Affiliation(s)
- C Lorena Manzanares Palenzuela
- Department of Inorganic Chemistry , University of Chemistry and Technology Prague , Technicka 5 , 166 28 Prague 6 , Czech Republic
| | - Filip Novotný
- Department of Inorganic Chemistry , University of Chemistry and Technology Prague , Technicka 5 , 166 28 Prague 6 , Czech Republic
| | - Petr Krupička
- Department of Inorganic Chemistry , University of Chemistry and Technology Prague , Technicka 5 , 166 28 Prague 6 , Czech Republic
| | - Zdeněk Sofer
- Department of Inorganic Chemistry , University of Chemistry and Technology Prague , Technicka 5 , 166 28 Prague 6 , Czech Republic
| | - Martin Pumera
- Department of Inorganic Chemistry , University of Chemistry and Technology Prague , Technicka 5 , 166 28 Prague 6 , Czech Republic
| |
Collapse
|
7
|
Du F, Fung YS. Dual-opposite multi-walled carbon nanotube modified carbon fiber microelectrode for microfluidic chip-capillary electrophoresis determination of methyl parathion metabolites in human urine. Electrophoresis 2018; 39:1375-1381. [DOI: 10.1002/elps.201700470] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/15/2017] [Revised: 02/09/2018] [Accepted: 02/19/2018] [Indexed: 11/09/2022]
Affiliation(s)
- Fuying Du
- Department of Water Quality Engineering; School of Power and Mechanical Engineering; Wuhan University; Wuhan P. R. China
- Department of Chemistry; University of Hong Kong; Hong Kong
- Key Laboratory of Analytical Chemistry for Biology and Medicine; Wuhan University; Ministry of Education; P. R. China
| | - Ying-Sing Fung
- Department of Chemistry; University of Hong Kong; Hong Kong
| |
Collapse
|
8
|
Ali MA, Tabassum S, Wang Q, Wang Y, Kumar R, Dong L. Integrated dual-modality microfluidic sensor for biomarker detection using lithographic plasmonic crystal. LAB ON A CHIP 2018; 18:803-817. [PMID: 29431801 DOI: 10.1039/c7lc01211j] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
This paper reports an integrated dual-modality microfluidic sensor chip, consisting of a patterned periodic array of nanoposts coated with gold (Au) and graphene oxide (GO), to detect target biomarker molecules in a limited sample volume. The device generates both electrochemical and surface plasmon resonance (SPR) signals from a single sensing area of Au-GO nanoposts. The Au-GO nanoposts are functionalized with specific receptor molecules, serving as a spatially well-defined nanostructured working electrode for electrochemical sensing, as well as a nanostructured plasmonic crystal for SPR-based sensing via the excitation of surface plasmon polaritons. High sensitivity of the electrochemical measurement originates from the presence of the nanoposts on the surface of the working electrode where radial diffusion of redox species occurs. Complementarily, the SPR detection allows convenient tracking of dynamic antigen-antibody interactions, to describe the association and dissociation phases occurring at the sensor surface. The soft-lithographically formed nanoposts provide high reproducibility of the sensor response to epidermal growth factor receptor (ErbB2) molecules even at a femtomolar level. Sensitivities of the electrochemical measurements to ErbB2 are found to be 20.47 μA μM-1 cm-2 in a range from 1 fM to 0.1 μM, and those of the SPR measurements to be 1.35 nm μM-1 in a range from 10 pM to 1 nM, and 0.80 nm μM-1 in a range from 1 nM to 0.1 μM. The integrated dual-modality sensor offers higher sensitivity (through higher surface area and diffusions from nanoposts for electrochemical measurements), as well as the dynamic measurements of antigen-antibody bindings (through the SPR measurement), while operating simultaneously in a same sensing area using the same sample volume.
Collapse
Affiliation(s)
- Md Azahar Ali
- Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011, USA.
| | | | | | | | | | | |
Collapse
|
9
|
Singh N, Ali MA, Rai P, Sharma A, Malhotra BD, John R. Microporous Nanocomposite Enabled Microfluidic Biochip for Cardiac Biomarker Detection. ACS APPLIED MATERIALS & INTERFACES 2017; 9:33576-33588. [PMID: 28892359 DOI: 10.1021/acsami.7b07590] [Citation(s) in RCA: 53] [Impact Index Per Article: 6.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/05/2023]
Abstract
This paper demonstrates an ultrasensitive microfluidic biochip nanoengineered with microporous manganese-reduced graphene oxide nanocomposite for detection of cardiac biomarker, namely human cardiac troponin I. In this device, the troponin sensitive microfluidic electrode consisted of a thin layer of manganese-reduced graphene oxide (Mn3O4-RGO) nanocomposite material. This nanocomposite thin layer was formed on surface of a patterned indium tin oxide substrate after modification with 3-aminopropyletriethoxysilane and was assembled with a polydimethylsiloxane-based microfluidic system. The nanoengineered microelectrode was functionalized with antibodies specific to cardiac troponin I. The uniformly distributed flower-shaped nanostructured manganese oxide (nMn3O4) onto RGO nanosheets offered large surface area for enhanced loading of antibody molecules and improved electrochemical reaction at the sensor surface. This microfluidic device showed an excellent sensitivity of log [87.58] kΩ/(ng mL-1)/cm2 for quantification of human cardiac troponin I (cTnI) molecules in a wide detection range of 0.008-20 ng/mL. This device was found to have high stability, high reproducibility, and minimal interference with other biomarkers cardiac troponin C and T, myoglobin, and B-type natriuretic peptide. These advantageous features of the Mn3O4-RGO nanocomposite, in conjunction with microfluidic integration, enabled a promising microfluidic biochip platform for point-of-care detection of cardiac troponin.
Collapse
Affiliation(s)
- Nawab Singh
- Department of Biomedical Engineering, Indian Institute of Technology Hyderabad Kandi , Sangareddy, Telangana 502285, India
| | - Md Azahar Ali
- Department of Electrical and Computer Engineering, Iowa State University , Ames, Iowa 50011, United States
| | - Prabhakar Rai
- Department of Chemical Engineering, Indian Institute of Technology Kanpur , Kanpur 208016, India
| | - Ashutosh Sharma
- Department of Chemical Engineering, Indian Institute of Technology Kanpur , Kanpur 208016, India
| | - B D Malhotra
- Department of Biotechnology, Delhi Technological University , Shahbad Daulatpur, Main Bawana Road, Delhi 110042, India
| | - Renu John
- Department of Biomedical Engineering, Indian Institute of Technology Hyderabad Kandi , Sangareddy, Telangana 502285, India
| |
Collapse
|
10
|
Ghasemi A, Amiri H, Zare H, Masroor M, Hasanzadeh A, Beyzavi A, Aref AR, Karimi M, Hamblin MR. Carbon nanotubes in microfluidic lab-on-a-chip technology: current trends and future perspectives. MICROFLUIDICS AND NANOFLUIDICS 2017; 21:151. [PMID: 30881265 PMCID: PMC6415915 DOI: 10.1007/s10404-017-1989-1] [Citation(s) in RCA: 17] [Impact Index Per Article: 2.1] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/15/2023]
Abstract
Advanced nanomaterials such as carbon nano-tubes (CNTs) display unprecedented properties such as strength, electrical conductance, thermal stability, and intriguing optical properties. These properties of CNT allow construction of small microfluidic devices leading to miniaturization of analyses previously conducted on a laboratory bench. With dimensions of only millimeters to a few square centimeters, these devices are called lab-on-a-chip (LOC). A LOC device requires a multidisciplinary contribution from different fields and offers automation, portability, and high-throughput screening along with a significant reduction in reagent consumption. Today, CNT can play a vital role in many parts of a LOC such as membrane channels, sensors and channel walls. This review paper provides an overview of recent trends in the use of CNT in LOC devices and covers challenges and recent advances in the field. CNTs are also reviewed in terms of synthesis, integration techniques, functionalization and superhydrophobicity. In addition, the toxicity of these nanomaterials is reviewed as a major challenge and recent approaches addressing this issue are discussed.
Collapse
Affiliation(s)
- Amir Ghasemi
- Department of Materials Science and Engineering, Sharif University of Technology, P.O. Box 11365-9466, Tehran 14588, Iran
- Advances Nanobiotechnology and Nanomedicine Research Group (ANNRG), Iran University of Medical Sciences, Tehran, Iran
| | - Hamed Amiri
- Department of Materials Science and Engineering, Sharif University of Technology, P.O. Box 11365-9466, Tehran 14588, Iran
| | - Hossein Zare
- Advances Nanobiotechnology and Nanomedicine Research Group (ANNRG), Iran University of Medical Sciences, Tehran, Iran
- Biomaterials Group, Materials Science and Engineering Department, Iran University of Science and Technology, P.O. Box 1684613114, Tehran, Iran
| | - Maryam Masroor
- Advances Nanobiotechnology and Nanomedicine Research Group (ANNRG), Iran University of Medical Sciences, Tehran, Iran
- School of Metallurgy and Materials Engineering, College of Engineering, University of Tehran, Tehran, Iran
| | - Akbar Hasanzadeh
- Department of Medical Nanotechnology, Faculty of Advanced Technologies in Medicine, Iran University of Medical Sciences, Tehran, Iran
| | - Ali Beyzavi
- School of Mechanical Engineering, Boston University, Boston, MA, USA
| | - Amir R. Aref
- Department of Medical Oncology, Belfer Center for Applied Cancer Science, Dana-Farber Cancer Institute, Harvard Medical School, Boston, MA 02215, USA
| | - Mahdi Karimi
- Cellular and Molecular Research Center, Iran University of Medical Sciences, Tehran, Iran
- Department of Medical Nanotechnology, Faculty of Advanced Technologies in Medicine, Iran University of Medical Sciences, Tehran, Iran
- Applied Biotechnology Research Center, Teheran Medical Sciences Branch, Isclamic Azad University, Teheran, Iran
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
- Research Center for Science and Technology in Medicine, Tehran University of Medical Sciences, Tehran, Iran
| | - Michael R. Hamblin
- Wellman Center for Photomedicine, Massachusetts General Hospital, Harvard Medical School, Boston, MA 02114, USA
- Department of Dermatology, Harvard Medical School, Boston, MA 02115, USA
- Harvard-MIT Division of Health Sciences and Technology, Cambridge, MA 02139, USA
| |
Collapse
|
11
|
Toh RJ, Mayorga-Martinez CC, Han J, Sofer Z, Pumera M. Group 6 Layered Transition-Metal Dichalcogenides in Lab-on-a-Chip Devices: 1T-Phase WS2 for Microfluidics Non-Enzymatic Detection of Hydrogen Peroxide. Anal Chem 2017; 89:4978-4985. [DOI: 10.1021/acs.analchem.7b00302] [Citation(s) in RCA: 28] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/05/2023]
Affiliation(s)
- Rou Jun Toh
- Division
of Chemistry and Biological Chemistry, School of Physical and Mathematical
Science, Nanyang Technological University, 637371 Singapore
- BioSystems & Micromechanics IRG (BioSyM), Singapore-MIT Alliance for Research and Technology (SMART) Centre, S16-05-08, 3 Science Drive 2, 117543 Singapore
| | - Carmen C. Mayorga-Martinez
- Division
of Chemistry and Biological Chemistry, School of Physical and Mathematical
Science, Nanyang Technological University, 637371 Singapore
| | - Jongyoon Han
- BioSystems & Micromechanics IRG (BioSyM), Singapore-MIT Alliance for Research and Technology (SMART) Centre, S16-05-08, 3 Science Drive 2, 117543 Singapore
- Department
of Electrical Engineering and Computer Science, Department of Biological
Engineering, Massachusetts Institute of Technology, Cambridge, Massachusetts 02139, United States
| | - Zdenek Sofer
- Department
of Inorganic Chemistry, University of Chemistry and Technology Prague, Technicka 5, 166 28 Prague 6, Czech Republic
| | - Martin Pumera
- Division
of Chemistry and Biological Chemistry, School of Physical and Mathematical
Science, Nanyang Technological University, 637371 Singapore
| |
Collapse
|
12
|
Ali MA, Mondal K, Wang Y, Jiang H, Mahal NK, Castellano MJ, Sharma A, Dong L. In situ integration of graphene foam-titanium nitride based bio-scaffolds and microfluidic structures for soil nutrient sensors. LAB ON A CHIP 2017; 17:274-285. [PMID: 28009868 DOI: 10.1039/c6lc01266c] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/06/2023]
Abstract
It is challenging to integrate porous graphene foam (GF) and GF-based nanocomposites into microfluidic channels and even create microfluidic structures within these materials. This is because their irregular interior pore shape and geometry, rough exterior surface, and relatively large material thickness make it difficult to perform conventional photolithography and etching. This challenge has largely hindered the potential of using GF-based materials in microfluidics-based sensors. Here we present a simple approach to create well-defined flow-through channels within or across the GF-based materials, using a liquid-phase photopolymerization method. This method allows embedding of a nanocomposite-based scaffold of GF and titanium nitride nanofibers (GF-TiN NFs) into a channel structure, to realize flow-through microfluidic electrochemical sensors for detecting nitrate ions in agricultural soils. The unique GF-TiN nanocomposite provides high electrochemical reactivity, high electron transfer rate, improved loading capacity of receptor biomolecules, and large surface area, serving as an efficient electrochemical sensing interface with the help of immobilized specific enzyme molecules. The microfluidic sensor provides an ultralow limit of detection of 0.01 mg L-1, a wide dynamic range from 0.01 to 442 mg L-1, and a high sensitivity of 683.3 μA mg-1 L cm-2 for nitrate ions in real soil solution samples. The advantageous features of the GF-TiN nanocomposite, in conjunction with the in situ integration approach, will enable a promising microfluidic sensor platform to monitor soil ions for nutrient management towards sustainable agriculture.
Collapse
Affiliation(s)
- Md Azahar Ali
- Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011, USA.
| | - Kunal Mondal
- Department of Chemical and Biomolecular Engineering, North Carolina State University, Raleigh, North Carolina 27695, USA
| | - Yifei Wang
- Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011, USA.
| | - Huawei Jiang
- Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011, USA.
| | - Navreet K Mahal
- Department of Agronomy, Iowa State University, Ames, Iowa 50011, USA
| | | | - Ashutosh Sharma
- Department of Chemical Engineering, Indian Institute of Technology Kanpur, Kanpur 208016, India
| | - Liang Dong
- Department of Electrical and Computer Engineering, Iowa State University, Ames, Iowa 50011, USA.
| |
Collapse
|
13
|
Shi L, Wang Y, Chu Z, Yin Y, Jiang D, Luo J, Ding S, Jin W. A highly sensitive and reusable electrochemical mercury biosensor based on tunable vertical single-walled carbon nanotubes and a target recycling strategy. J Mater Chem B 2017; 5:1073-1080. [DOI: 10.1039/c6tb02658c] [Citation(s) in RCA: 35] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/18/2022]
Abstract
Conformational regulation of SAMs was proposed for controlled growth of v-SWCNTs, which were employed to construct a high-performance mercury biosensor using a target recycling strategy.
Collapse
Affiliation(s)
- Lei Shi
- State Key Laboratory of Lake Science and Environment
- Nanjing Institute of Geography and Limnology
- Chinese Academy of Sciences
- Nanjing 210008
- P. R. China
| | - Yan Wang
- State Key Laboratory of Lake Science and Environment
- Nanjing Institute of Geography and Limnology
- Chinese Academy of Sciences
- Nanjing 210008
- P. R. China
| | - Zhenyu Chu
- State Key Laboratory of Materials-Oriented Chemical Engineering
- College of Chemical Engineering
- Nanjing Tech University
- Nanjing 210009
- P. R. China
| | - Yu Yin
- School of Environmental and Chemical Engineering
- Jiangsu University of Science and Technology
- Zhenjiang 212003
- P. R. China
| | - Danfeng Jiang
- State Key Laboratory of Materials-Oriented Chemical Engineering
- College of Chemical Engineering
- Nanjing Tech University
- Nanjing 210009
- P. R. China
| | - Jingyi Luo
- State Key Laboratory of Materials-Oriented Chemical Engineering
- College of Chemical Engineering
- Nanjing Tech University
- Nanjing 210009
- P. R. China
| | - Shiming Ding
- State Key Laboratory of Lake Science and Environment
- Nanjing Institute of Geography and Limnology
- Chinese Academy of Sciences
- Nanjing 210008
- P. R. China
| | - Wanqin Jin
- State Key Laboratory of Materials-Oriented Chemical Engineering
- College of Chemical Engineering
- Nanjing Tech University
- Nanjing 210009
- P. R. China
| |
Collapse
|
14
|
Tailor designed exclusive carbon nanomaterial electrodes for off-chip and on-chip electrochemical detection. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-2020-3] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/27/2022]
|
15
|
Della Pelle F, Del Carlo M, Sergi M, Compagnone D, Escarpa A. Press-transferred carbon black nanoparticles on board of microfluidic chips for rapid and sensitive amperometric determination of phenyl carbamate pesticides in environmental samples. Mikrochim Acta 2016. [DOI: 10.1007/s00604-016-1964-7] [Citation(s) in RCA: 36] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/28/2022]
|
16
|
García-Carmona L, Martín A, Sierra T, González MC, Escarpa A. Electrochemical detectors based on carbon and metallic nanostructures in capillary and microchip electrophoresis. Electrophoresis 2016; 38:80-94. [DOI: 10.1002/elps.201600232] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/17/2016] [Revised: 06/27/2016] [Accepted: 06/28/2016] [Indexed: 11/07/2022]
Affiliation(s)
- Laura García-Carmona
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering; University of Alcalá; Madrid Spain
| | - Aida Martín
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering; University of Alcalá; Madrid Spain
| | - Tania Sierra
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering; University of Alcalá; Madrid Spain
| | - María Cristina González
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering; University of Alcalá; Madrid Spain
| | - Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering; University of Alcalá; Madrid Spain
| |
Collapse
|
17
|
Ibañez D, Garoz-Ruiz J, Heras A, Colina A. Simultaneous UV–Visible Absorption and Raman Spectroelectrochemistry. Anal Chem 2016; 88:8210-7. [DOI: 10.1021/acs.analchem.6b02008] [Citation(s) in RCA: 26] [Impact Index Per Article: 2.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/14/2023]
Affiliation(s)
- David Ibañez
- Department of Chemistry, Universidad de Burgos, Pza. Misael
Bañuelos s/n, E-09001 Burgos, Spain
| | - Jesus Garoz-Ruiz
- Department of Chemistry, Universidad de Burgos, Pza. Misael
Bañuelos s/n, E-09001 Burgos, Spain
| | - Aranzazu Heras
- Department of Chemistry, Universidad de Burgos, Pza. Misael
Bañuelos s/n, E-09001 Burgos, Spain
| | - Alvaro Colina
- Department of Chemistry, Universidad de Burgos, Pza. Misael
Bañuelos s/n, E-09001 Burgos, Spain
| |
Collapse
|
18
|
Della Pelle F, Vázquez L, Del Carlo M, Sergi M, Compagnone D, Escarpa A. Press-Printed Conductive Carbon Black Nanoparticle Films for Molecular Detection at the Microscale. Chemistry 2016; 22:12761-6. [PMID: 27460290 DOI: 10.1002/chem.201601743] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/13/2016] [Indexed: 11/08/2022]
Abstract
Carbon black nanoparticle (CBNP) press-transferred film-based transducers for the molecular detection at the microscale level were proposed for the first time. Current-sensing atomic force microscopy (CS-AFM) revealed that the CBNP films were effectively press-transferred, retaining their good conductivity. A significant correlation between the morphology and the resistance was observed. The highest resistance was localized at the top of the press-transferred film protrusions, whereas low values are usually obtained at the deep crevices or grooves. The amount of press-transferred CBNPs is the key parameter to obtain films with improved conductivity, which is in good agreement with the electrochemical response. In addition, the conductivity of such optimum films was not only Ohmic; in fact, tunneling/hopping contributions were observed, as assessed by CS-AFM. The CBNP films acted as exclusive electrochemical transducers as evidenced by using two classes of molecules, that is, neurotransmitters and environmental organic contaminants. These results revealed the potential of these CBNP press-transferred films for providing new options in microfluidics and other related micro- and nanochemistry applications.
Collapse
Affiliation(s)
- Flavio Della Pelle
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Biology, Environmental Sciences and Chemistry, University of Alcalá, E-28871, Alcalá de Henares, Madrid, Spain), Fax: (+34) 918854971.,Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, 64023, Teramo, Italy), Fax:(+39) 0861-266942
| | - Luis Vázquez
- Institute of Materials Science of Madrid (CSIC), C/Sor Juana Inés de la Cruz No 3, Cantoblanco, 28049, Madrid, Spain
| | - Michele Del Carlo
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, 64023, Teramo, Italy), Fax:(+39) 0861-266942
| | - Manuel Sergi
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, 64023, Teramo, Italy), Fax:(+39) 0861-266942
| | - Dario Compagnone
- Faculty of Bioscience and Technology for Food, Agriculture and Environment, University of Teramo, 64023, Teramo, Italy), Fax:(+39) 0861-266942.
| | - Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Biology, Environmental Sciences and Chemistry, University of Alcalá, E-28871, Alcalá de Henares, Madrid, Spain), Fax: (+34) 918854971.
| |
Collapse
|
19
|
Garoz-Ruiz J, Ibañez D, Romero EC, Ruiz V, Heras A, Colina A. Optically transparent electrodes for spectroelectrochemistry fabricated with graphene nanoplatelets and single-walled carbon nanotubes. RSC Adv 2016. [DOI: 10.1039/c6ra04116g] [Citation(s) in RCA: 12] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022] Open
Abstract
Hybrid optically transparent electrodes based on single-walled carbon nanotubes and graphene nanoplatelets have been fabricated. The new methodology can be used with other carbon nanomaterials.
Collapse
Affiliation(s)
| | - David Ibañez
- Department of Chemistry
- Universidad de Burgos
- E-09001 Burgos
- Spain
| | - Edna C. Romero
- Department of Chemistry
- Universidad de Burgos
- E-09001 Burgos
- Spain
| | - Virginia Ruiz
- IK4-CIDETEC
- Materials Division
- E-20009 San Sebastián
- Spain
| | - Aranzazu Heras
- Department of Chemistry
- Universidad de Burgos
- E-09001 Burgos
- Spain
| | - Alvaro Colina
- Department of Chemistry
- Universidad de Burgos
- E-09001 Burgos
- Spain
| |
Collapse
|
20
|
Herrasti Z, Martínez F, Baldrich E. Reversible nanostructuration of microfluidic electrode devices by CNT magnetic co-entrapment. LAB ON A CHIP 2015; 15:3269-3273. [PMID: 26155767 DOI: 10.1039/c5lc00573f] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.1] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/04/2023]
Abstract
Carbon nanotubes (CNTs) have been extensively used to produce electrodes of enhanced performance but have only been very recently exploited in microfluidic devices. In these cases, CNT electrodes had to be produced prior to device assembly, which might damage the CNT layer. Here, we show a fast and simple method for the reversible nanostructuration of microfluidic electrode devices in situ. The procedure is based on the attachment of single-walled CNTs (SWCNTs) onto the surface of magnetic particles (MPs) and magnetic confinement of the MP/SWCNT composite onto the sensor in a two-step process that provided homogeneous coating. As it is shown, subsequent magnet removal allows MP/SWCNT release and electrode reutilization. Compared to most previously described methods, ours is faster, simpler and also reversible.
Collapse
Affiliation(s)
- Zorione Herrasti
- IK4-Ikerlan Technological Research Centre, 20500 Mondragón, Spain
| | | | | |
Collapse
|
21
|
Randviir EP, Banks CE. Electrode substrate innovation for electrochemical detection in microchip electrophoresis. Electrophoresis 2015; 36:1845-53. [DOI: 10.1002/elps.201500153] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/22/2015] [Revised: 05/11/2015] [Accepted: 05/11/2015] [Indexed: 11/09/2022]
Affiliation(s)
- Edward P. Randviir
- Division of Chemistry and Environmental Science; Faculty of Science and Engineering; School of Chemistry and the Environment, Manchester Metropolitan University; Lancs UK
| | - Craig E. Banks
- Division of Chemistry and Environmental Science; Faculty of Science and Engineering; School of Chemistry and the Environment, Manchester Metropolitan University; Lancs UK
| |
Collapse
|
22
|
Garoz-Ruiz J, Heras A, Palmero S, Colina A. Development of a Novel Bidimensional Spectroelectrochemistry Cell Using Transfer Single-Walled Carbon Nanotubes Films as Optically Transparent Electrodes. Anal Chem 2015; 87:6233-9. [DOI: 10.1021/acs.analchem.5b00923] [Citation(s) in RCA: 30] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/30/2023]
Affiliation(s)
- Jesus Garoz-Ruiz
- Department of Chemistry, Universidad de Burgos, Pza. Misael
Bañuelos s/n, E-09001 Burgos, Spain
| | - Aranzazu Heras
- Department of Chemistry, Universidad de Burgos, Pza. Misael
Bañuelos s/n, E-09001 Burgos, Spain
| | - Susana Palmero
- Department of Chemistry, Universidad de Burgos, Pza. Misael
Bañuelos s/n, E-09001 Burgos, Spain
| | - Alvaro Colina
- Department of Chemistry, Universidad de Burgos, Pza. Misael
Bañuelos s/n, E-09001 Burgos, Spain
| |
Collapse
|
23
|
Batalla P, Martín A, López MÁ, González MC, Escarpa A. Enzyme-Based Microfluidic Chip Coupled to Graphene Electrodes for the Detection of D-Amino Acid Enantiomer-Biomarkers. Anal Chem 2015; 87:5074-8. [DOI: 10.1021/acs.analchem.5b00979] [Citation(s) in RCA: 57] [Impact Index Per Article: 5.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/28/2023]
Affiliation(s)
- Pilar Batalla
- Department of Analytical
Chemistry, Physical Chemistry and Chemical Engineering, Faculty of
Biology, Environmental Sciences and Chemistry, University of Alcalá, E-28871, Alcalá de Henares, Madrid, Spain
| | - Aída Martín
- Department of Analytical
Chemistry, Physical Chemistry and Chemical Engineering, Faculty of
Biology, Environmental Sciences and Chemistry, University of Alcalá, E-28871, Alcalá de Henares, Madrid, Spain
| | - Miguel Ángel López
- Department of Analytical
Chemistry, Physical Chemistry and Chemical Engineering, Faculty of
Biology, Environmental Sciences and Chemistry, University of Alcalá, E-28871, Alcalá de Henares, Madrid, Spain
| | - María Cristina González
- Department of Analytical
Chemistry, Physical Chemistry and Chemical Engineering, Faculty of
Biology, Environmental Sciences and Chemistry, University of Alcalá, E-28871, Alcalá de Henares, Madrid, Spain
| | - Alberto Escarpa
- Department of Analytical
Chemistry, Physical Chemistry and Chemical Engineering, Faculty of
Biology, Environmental Sciences and Chemistry, University of Alcalá, E-28871, Alcalá de Henares, Madrid, Spain
| |
Collapse
|
24
|
Gomez FJV, Martín A, Silva MF, Escarpa A. Microchip electrophoresis-single wall carbon nanotube press-transferred electrodes for fast and reliable electrochemical sensing of melatonin and its precursors. Electrophoresis 2015; 36:1880-5. [PMID: 25735903 DOI: 10.1002/elps.201400580] [Citation(s) in RCA: 27] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/05/2014] [Revised: 01/08/2015] [Accepted: 02/04/2015] [Indexed: 11/07/2022]
Abstract
In the current work, single-wall carbon nanotube press-transferred electrodes (SW-PTEs) were used for detection of melatonin (MT) and its precursors tryptophan (Trp) and serotonin (5-HT) on microchip electrophoresis (ME). SW-PTEs were simply fabricated by press transferring a filtered dispersion of single-wall carbon nanotubes on a nonconductive PMMA substrate, where single-wall carbon nanotubes act as exclusive transducers. The coupling of ME-SW-PTEs allowed the fast detection of MT, Trp, and 5-HT in less than 150 s with excellent analytical features. It exhibited an impressive antifouling performance with RSD values of ≤2 and ≤4% for migration times and peak heights, respectively (n = 12). In addition, sample analysis was also investigated by analysis of 5-HT, MT, and Trp in commercial samples obtaining excellent quantitative and reproducible recoveries with values of 96.2 ± 1.8%, 101.3 ± 0.2%, and 95.6 ± 1.2% for 5-HT, MT, and Trp, respectively. The current novel application reveals the analytical power of the press-transfer technology where the fast and reliable determination of MT and its precursors were performed directly on the nanoscale carbon nanotube detectors without the help of any other electrochemical transducer.
Collapse
Affiliation(s)
- Federico José Vicente Gomez
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, Madrid, Spain.,Instituto de Biología Agrícola de Mendoza (IBAM-CONICET), Facultad de Ciencias Agrarias, Universidad Nacional de Cuyo, Mendoza, Argentina
| | - Aída Martín
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, Madrid, Spain
| | - María Fernanda Silva
- Instituto de Biología Agrícola de Mendoza (IBAM-CONICET), Facultad de Ciencias Agrarias, Universidad Nacional de Cuyo, Mendoza, Argentina
| | - Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, University of Alcalá, Alcalá de Henares, Madrid, Spain
| |
Collapse
|
25
|
Govindhan M, Lafleur T, Adhikari BR, Chen A. Electrochemical Sensor Based on Carbon Nanotubes for the Simultaneous Detection of Phenolic Pollutants. ELECTROANAL 2015. [DOI: 10.1002/elan.201400608] [Citation(s) in RCA: 63] [Impact Index Per Article: 6.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/07/2022]
|
26
|
Li Z, Yu Y, Li Z, Wu T. A review of biosensing techniques for detection of trace carcinogen contamination in food products. Anal Bioanal Chem 2015; 407:2711-26. [PMID: 25694149 DOI: 10.1007/s00216-015-8530-8] [Citation(s) in RCA: 25] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/26/2014] [Revised: 01/24/2015] [Accepted: 01/30/2015] [Indexed: 01/04/2023]
Abstract
Carcinogen contaminations in the food chain, for example heavy metal ions, pesticides, acrylamide, and mycotoxins, have caused serious health problems. A major objective of food-safety research is the identification and prevention of exposure to these carcinogens, because of their impossible-to-reverse tumorigenic effects. However, carcinogen detection is difficult because of their trace-level presence in food. Thus, reliable and accurate separation and determination methods are essential to protect food safety and human health. This paper summarizes the state of the art in separation and determination methods for analyzing carcinogen contamination, especially the advances in biosensing methods. Furthermore, the application of promising technology including nanomaterials, imprinted polymers, and microdevices is detailed. Challenges and perspectives are also discussed.
Collapse
Affiliation(s)
- Zhanming Li
- Department of Biosystems Engineering, Zhejiang University, Hangzhou, 310058, China
| | | | | | | |
Collapse
|
27
|
Present state of microchip electrophoresis: state of the art and routine applications. J Chromatogr A 2014; 1382:66-85. [PMID: 25529267 DOI: 10.1016/j.chroma.2014.11.034] [Citation(s) in RCA: 130] [Impact Index Per Article: 11.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2014] [Revised: 11/07/2014] [Accepted: 11/12/2014] [Indexed: 12/20/2022]
Abstract
Microchip electrophoresis (MCE) was one of the earliest applications of the micro-total analysis system (μ-TAS) concept, whose aim is to reduce analysis time and reagent and sample consumption while increasing throughput and portability by miniaturizing analytical laboratory procedures onto a microfluidic chip. More than two decades on, electrophoresis remains the most common separation technique used in microfluidic applications. MCE-based instruments have had some commercial success and have found application in many disciplines. This review will consider the present state of MCE including recent advances in technology and both novel and routine applications in the laboratory. We will also attempt to assess the impact of MCE in the scientific community and its prospects for the future.
Collapse
|
28
|
Martín A, López MÁ, González MC, Escarpa A. Multidimensional carbon allotropes as electrochemical detectors in capillary and microchip electrophoresis. Electrophoresis 2014; 36:179-94. [DOI: 10.1002/elps.201400328] [Citation(s) in RCA: 44] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2014] [Revised: 08/22/2014] [Accepted: 08/22/2014] [Indexed: 12/29/2022]
Affiliation(s)
- Aída Martín
- Department of Analytical Chemistry; Physical Chemistry and Chemical Engineering; University of Alcalá; Madrid Spain
| | - Miguel Ángel López
- Department of Analytical Chemistry; Physical Chemistry and Chemical Engineering; University of Alcalá; Madrid Spain
| | - María Cristina González
- Department of Analytical Chemistry; Physical Chemistry and Chemical Engineering; University of Alcalá; Madrid Spain
| | - Alberto Escarpa
- Department of Analytical Chemistry; Physical Chemistry and Chemical Engineering; University of Alcalá; Madrid Spain
| |
Collapse
|
29
|
A comparative study of different microchips for capillary electrophoresis with electrochemical detection. J APPL ELECTROCHEM 2014. [DOI: 10.1007/s10800-014-0764-1] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/24/2022]
|
30
|
Abstract
These insights attempt to share with the community the lights and shadows of one emerging and exciting topic, Food Microfluidics, defined as microfluidic technology for food analysis and diagnosis in important areas such as food safety and quality. The reader is invited to question non-easy interrogations such as why Food Microfluidics, what is the next step and what could we do with the available technology. This article invites food analysts to be seduced by this technology and then to take an interesting trip departing from the main gained achievements, having a look at the crossing bridges over Food Microfluidic challenges or having a look at available technology to start. Finally, this trip arrives at a privileged place to gaze the horizons. A wonderful landscape--full of inspiration--for Food Microfluidics is anticipated. These insights have also been written wishing to give improved conceptual and realistic solutions for food analysis, with the additional hope to attract the community with exciting technology, in order to get novel and unexpected achievements in this field.
Collapse
Affiliation(s)
- Alberto Escarpa
- Department of Analytical Chemistry, Physical Chemistry and Chemical Engineering, Faculty of Chemistry, University of Alcalá E-28871, Ctra. Madrid-Barcelona km 33,600. 28871, Alcalá de Henares, Madrid, Spain.
| |
Collapse
|
31
|
Hofmann MC. Stem cells and nanomaterials. ADVANCES IN EXPERIMENTAL MEDICINE AND BIOLOGY 2014; 811:255-75. [PMID: 24683036 DOI: 10.1007/978-94-017-8739-0_13] [Citation(s) in RCA: 16] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 01/12/2023]
Abstract
Because of their ability to self-renew and differentiate into many cell types, stem cells offer the potential to be used for tissue regeneration and engineering. Much progress has recently been made in our understanding of the biology of stem cells and our ability to manipulate their proliferation and differentiation to obtain functional tissues. Similarly, nanomaterials have been recently developed that will accelerate discovery of mechanisms driving stem cell fate and their utilization in medicine. Nanoparticles have been developed that allow the labeling and tracking of stem cells and their differentiated phenotype within an organism. Nanosurfaces are engineered that mimic the extracellular matrix to which stem cells adhere and migrate. Scaffolds made of functionalized nanofibers can now be used to grow stem cells and regenerate damaged tissues and organs. However, the small scale of nanomaterials induces changes in their chemical and physical properties that might modify their interactions with cells and tissues, and render them toxic to stem cells. Therefore a thorough understanding of stem cell-nanomaterial interactions is still necessary not only to accelerate the success of medical treatments but also to ensure the safety of the tools provided by these novel technologies.
Collapse
Affiliation(s)
- Marie-Claude Hofmann
- Department of Endocrine Neoplasia and Hormonal Disorders, University of Texas MD Anderson Cancer Center, Houston, TX, USA,
| |
Collapse
|
32
|
Dossi N, Toniolo R, Impellizzieri F, Bontempelli G. Doped pencil leads for drawing modified electrodes on paper-based electrochemical devices. J Electroanal Chem (Lausanne) 2014. [DOI: 10.1016/j.jelechem.2014.03.038] [Citation(s) in RCA: 52] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
33
|
García M, Batalla P, Escarpa A. Metallic and polymeric nanowires for electrochemical sensing and biosensing. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.01.004] [Citation(s) in RCA: 33] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
|
34
|
Sierra-Rodero M, Fernández-Romero JM, Gómez-Hens A. Strategies to improve the analytical features of microfluidic methods using nanomaterials. Trends Analyt Chem 2014. [DOI: 10.1016/j.trac.2014.01.006] [Citation(s) in RCA: 10] [Impact Index Per Article: 0.9] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/25/2022]
|
35
|
Vilela D, Martín A, González MC, Escarpa A. Fast and reliable class-selective isoflavone index determination on carbon nanotube press-transferred electrodes using microfluidic chips. Analyst 2014; 139:2342-7. [DOI: 10.1039/c4an00025k] [Citation(s) in RCA: 22] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Direct microfluidic electrochemical sensing of class-isoflavones in complex soy samples on press-transferred carbon nanotubes.
Collapse
Affiliation(s)
- D. Vilela
- Department of Analytical Chemistry
- Physical Chemistry and Chemical Engineering
- University of Alcalá
- E-28871 Alcalá de Henares, Spain
| | - A. Martín
- Department of Analytical Chemistry
- Physical Chemistry and Chemical Engineering
- University of Alcalá
- E-28871 Alcalá de Henares, Spain
| | - M. C. González
- Department of Analytical Chemistry
- Physical Chemistry and Chemical Engineering
- University of Alcalá
- E-28871 Alcalá de Henares, Spain
| | - A. Escarpa
- Department of Analytical Chemistry
- Physical Chemistry and Chemical Engineering
- University of Alcalá
- E-28871 Alcalá de Henares, Spain
| |
Collapse
|
36
|
Benavidez TE, Garcia CD. Spectroscopic and electrochemical characterization of nanostructured optically transparent carbon electrodes. Electrophoresis 2013; 34:1998-2006. [PMID: 23595607 PMCID: PMC3860877 DOI: 10.1002/elps.201300022] [Citation(s) in RCA: 13] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/16/2013] [Revised: 02/15/2013] [Accepted: 03/03/2013] [Indexed: 12/15/2022]
Abstract
The present paper describes the results related to the optical and electrochemical characterization of thin carbon films fabricated by spin coating and pyrolysis of AZ P4330-RS photoresist. The goal of this paper is to provide comprehensive information allowing for the rational selection of the conditions to fabricate optically transparent carbon electrodes (OTCE) with specific electrooptical properties. According to our results, these electrodes could be appropriate choices as electrochemical transducers to monitor electrophoretic separations. At the core of this manuscript is the development and critical evaluation of a new optical model to calculate the thickness of the OTCE by variable angle spectroscopic ellipsometry. Such data were complemented with topography and roughness (obtained by atomic force microscopy), electrochemical properties (obtained by cyclic voltammetry), electrical properties (obtained by electrochemical impedance spectroscopy), and structural composition (obtained by Raman spectroscopy). Although the described OTCE were used as substrates to investigate the effect of electrode potential on the real-time adsorption of proteins by ellipsometry, these results could enable the development of other biosensors that can be then integrated into various CE platforms.
Collapse
Affiliation(s)
- Tomas E. Benavidez
- Department of Chemistry, The University of Texas at San Antonio One UTSA Circle, San Antonio, TX 78249, USA
| | - Carlos D. Garcia
- Department of Chemistry, The University of Texas at San Antonio One UTSA Circle, San Antonio, TX 78249, USA
| |
Collapse
|
37
|
Optical fiber spectroelectrochemical device for detection of catechol at press-transferred single-walled carbon nanotubes electrodes. Anal Bioanal Chem 2013; 405:3593-602. [DOI: 10.1007/s00216-013-6762-z] [Citation(s) in RCA: 15] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/26/2012] [Revised: 01/17/2013] [Accepted: 01/18/2013] [Indexed: 10/27/2022]
|