1
|
Bioanalytical technologies using temperature-responsive polymers. ANAL SCI 2024; 40:827-841. [PMID: 38584205 PMCID: PMC11035477 DOI: 10.1007/s44211-024-00545-3] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/27/2023] [Accepted: 02/24/2024] [Indexed: 04/09/2024]
Abstract
In recent decades, various bioanalytical technologies have been investigated for appropriate medical treatment and effective therapy. Temperature-responsive chromatography is a promising bioanalytical technology owing to its functional properties. Temperature-responsive chromatography uses a poly(N-isopropylacrylamide)(PNIPAAm) modified stationary phase as the column packing material. The hydrophobic interactions between PNIPAAm and the analyte could be modulated by changing the column temperature because of the temperature-responsive hydrophobicity of PNIPAAm. Thus, the chromatography system does not require organic solvents in the mobile phase, making it suitable for therapeutic drug monitoring in medical settings such as hospitals. This review summarizes recent developments in temperature-responsive chromatography systems for therapeutic drug monitoring applications. In addition, separation methods for antibody drugs using PNIPAAm are also summarized because these methods apply to the therapeutic drug monitoring of biopharmaceutics. The temperature-responsive chromatography systems can also be utilized for clinical diagnosis, as they can assess multiple medicines simultaneously. This highlights the significant potential of temperature-responsive chromatography in medicine and healthcare.
Collapse
|
2
|
On-column modification for the creation of temperature-responsive stationary phases. Anal Chim Acta 2023; 1283:341961. [PMID: 37977785 DOI: 10.1016/j.aca.2023.341961] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/24/2023] [Revised: 10/23/2023] [Accepted: 10/24/2023] [Indexed: 11/19/2023]
Abstract
Temperature-responsive liquid chromatography (TRLC) offers an alternative for retention and selectivity optimisation in HPLC. This approach thereby exploits temperature gradients on stimuli-responsive stationary phases and forfeits the necessity for solvent gradients, allowing analyses to be performed using aqueous mobile phases. Consequently, it can be employed as a green alternative to reversed-phase separations. However, current production to obtain temperature-responsive columns inherently require dedicated column packing processes with polymer-modified particles. To facilitate the development of temperature-responsive phases, a flow-through modification procedure was developed allowing on-column modification of aminopropyl silica columns. Three columns were manufactured using this novel flow-through approach, which achieved identical column efficiencies compared to existing TRLC column. Demonstrating the possibility of bypassing the dedicated packing processes without losing efficiency. Additionally, it was observed that flow-through produced columns yielded higher retention at elevated temperatures despite their reduced carbon load. Further investigation of the carbon load revealed the presence of stationary phase gradients, whose influence was studied via novel developed retention experiments, which revealed a negligible change reduction in retention upon a change of polymer modification from 19.8% to 14.5%. However, further decrease from 14.5% to 12.3% resulted in a larger change. Interestingly, a further enhancement in apparent plate numbers was observed when operating the column under a reversed flow, yielding an increasing stationary phase gradient. This on-column modification procedure demonstrates the potential for modification of existing (commercial) packed columns to achieve temperature-responsive phases without loss of efficiency or retention. Thus, not only facilitating accessibility to temperature-responsive phases, but also aiding with development of further generations of temperature-responsive phases by removing the need for packing optimisation. Additionally, a novel experiment was set up to easily investigate the effect of inhomogeneous stationary phases retention.
Collapse
|
3
|
Mechanistic study of ultrasound-assisted chromatography using plastic and stainless steel columns. J Chromatogr A 2023; 1710:464402. [PMID: 37797422 DOI: 10.1016/j.chroma.2023.464402] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/31/2023] [Revised: 09/01/2023] [Accepted: 09/19/2023] [Indexed: 10/07/2023]
Abstract
Based on the previous ultrasound-assisted chromatography (UAC) studies on plastic and stainless steel (SS) columns, this study explores the UAC mechanism by comparatively analyzing ultrasound effects on plastic and SS columns with C18 stationary phase when separating a mixture of polycyclic aromatic hydrocarbons (PAHs) under various ultrasound intensities. The results showed a substantial difference in H values between the PEEK and SS columns under the influence of ultrasound agitation. Specifically, for the pyrene peak, as the ultrasonic intensity increased from 0% to 100% of 900 W, the H values of the SS column slightly rose from 8.82 μm to 9.86 μm. Conversely, the corresponding values for the PEEK column exhibited a significant 12-fold increase from 11.5 μm to 134 μm. The findings demonstrated poor penetration of ultrasound energy through the SS column, and the temperature rise of the medium induced by the ultrasound was the primary contributing factor to PAH separation. However, ultrasound easily penetrated through the plastic column, resulting in acoustic cavitation within the C18 polyether ether ketone (PEEK) column. Cavitation induced heat generation and contributed to a decrease in retention time and the magnitude of peak broadening or distortion, depending on the specific ultrasonic energy. Based on the estimated change in inlet temperature of the PEEK column due to an acoustic effect, the comparison with temperature effects under non-sonic conditions consistently demonstrated a stronger acoustic effect in reducing the retention time, by 2-9%, depending on specific peaks and pairs. We revisited the previously described separation mechanism of ultrasound-assisted ion chromatography and conjoined with our findings to infer and establish a thorough explanation for the previously unexplained separation mechanism of chiral separation and size exclusion chromatography by UAC using SS columns.
Collapse
|
4
|
A surface-grafted hydrogel demonstrating thermoresponsive adhesive strength change. SOFT MATTER 2023; 19:3249-3252. [PMID: 37099019 DOI: 10.1039/d3sm00397c] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/11/2023]
Abstract
Here, we designed a surface-grafted hydrogel (SG gel) that exhibits thermoresponsive changes in surface properties. Quantitative measurements using a self-made device showed that the adhesive strength between the SG gel surface and a Bakelite plate due to hydrophobic interaction changed significantly with temperature.
Collapse
|
5
|
Thermoresponsive bio-affinity interfaces for temperature-modulated selective capture and release of targeted exosomes. Mater Today Bio 2022; 18:100521. [PMID: 36590982 PMCID: PMC9800632 DOI: 10.1016/j.mtbio.2022.100521] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/04/2022] [Revised: 12/01/2022] [Accepted: 12/10/2022] [Indexed: 12/14/2022]
Abstract
The existing methods for exosome isolation, such as ultracentrifugation, size exclusion, and affinity separation, suffer from some limitations. Herein, we aimed to develop temperature-modulated exosome-capturing materials using thermoresponsive polymers and peptides with affinity for exosomes. Poly(2-hydroxyethyl methacrylate-co-propargyl acrylate)-b-poly(N-isopropylacrylamide) (P(HEMA-co-PgA)-b-PNIPAAm) was grafted on silica beads via a two-step process of activator regenerated by electron transfer atom transfer radical polymerization. Peptides with affinity for exosomes were conjugated to the propargyl group of the bottom P(HEMA-co-PgA) segment of the copolymer via a click reaction. The prepared copolymer-grafted beads were characterized by elemental analysis, X-ray photoelectron spectroscopy, scanning electron microscopy, transmission electron microscopy, gel permeation chromatography, and the turbidity of the polymer solution. Results indicated that the copolymer and peptide were successfully modified on the silica beads. Exosomes from SK-BR-3 cells, a human breast cancer cell line, were selectively captured on the prepared beads at 37 °C, as the upper PNIPAAm segment shrank and the affinity between the peptide and exosome was enhanced. Upon lowering the temperature to 4 °C, the captured exosomes were released from the copolymer brush because of the extension of the PNIPAAm segment that reduced the affinity between peptides and exosomes. These findings demonstrated that the prepared copolymer brush-grafted silica beads can capture and release targeted exosomes via temperature modulation. Taken together, the developed copolymer brush-grafted silica beads would be useful for the separation of exosomes using simple procedures such as temperature modulation.
Collapse
|
6
|
A thermoresponsive cationic block copolymer brush-grafted silica bead interface for temperature-modulated separation of adipose-derived stem cells. Colloids Surf B Biointerfaces 2022; 220:112928. [DOI: 10.1016/j.colsurfb.2022.112928] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/03/2022] [Revised: 10/07/2022] [Accepted: 10/11/2022] [Indexed: 11/06/2022]
|
7
|
Perspectives in Hydrophobic Interaction Temperature- Responsive Liquid Chromatography (TRLC). LCGC NORTH AMERICA 2022. [DOI: 10.56530/lcgc.na.vd2373d8] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Temperature-responsive liquid chromatography (TRLC) is an emerging green high performance liquid chromatography (HPLC) mode allowing reversed phase-type separations while necessitating only water as the mobile phase. The columns therein are typically packed with silica particles to which stimuli-responsive polymers are anchored. In hydrophobic interaction TRLC, such polymers depict a loss of water solubility when increasing the temperature above a characteristic conversion temperature, causing large changes in retention over quite narrow and mild temperature ranges (~5–55 °C). TRLC circumvents the concerns about analyte or column degradation that can occur when implementing high temperatures (>80 °C) on conventional reversed- phase columns. It allows for high performance liquid chromatography (HPLC) using only water often spiked with the additives typically used in reversed-phase LC. Therefore, this separation mode allows for greener, cheaper, and isocratic analyses under non-denaturing conditions. The absence of compositional solvent gradients also allows for the exploitation of temperature gradients in combination with refractive index detection. Purely aqueous hydrophobic interaction TRLC is mostly applicable for solutes depicting a 1 < LogP < 5, yet these ranges can be expanded through implementation of combined aqueous or organic mobiles phases, while preserving the temperature-responsive effects. In this first TRLC installment, our recent developments, new possibilities, and current limitations of the use of 1-D TRLC are discussed, while the column performance is described with respect to the fundamentals of HPLC.
Collapse
|
8
|
Thermoresponsive block copolymer brush for temperature-modulated hepatocyte separation. J Mater Chem B 2022; 10:8629-8641. [PMID: 35972447 DOI: 10.1039/d2tb01384c] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Hepatic tissue engineering may be an effective approach for the treatment of liver disease; however, its practical application requires hepatic cell separation technologies that do not involve cell surface modification and maintain cell activity. In this study, we developed hepatocyte cell separation materials using a thermoresponsive polymer and a polymer with high affinity to hepatocytes. A block copolymer of poly(N-p-vinylbenzyl-O-β-D-galactopyranosyl-(1→4)-D-gluconamide) (PVLA) and poly(N-isopropylacrylamide) (PNIPAAm) [PVLA-b-PNIPAAm] was prepared through two steps of atom transfer radical polymerization. On the prepared PVLA-b-PNIPAAm brush, HepG2 cells (model hepatocytes) adhered at 37 °C and detached at 20 °C, attributed to the temperature-modulated affinity between PVLA and HepG2. Cells from the immortalized human hepatic stellate cell line (TWNT-1) did not adhere to the copolymer brush, and RAW264.7 cells (mouse macrophage; model Kupffer cells) adhered to the copolymer brush, regardless of temperature. Using the difference in cell adhesion properties on the copolymer brush, temperature-modulated cell separation was successfully demonstrated. A mixture of HepG2, RAW264.7, and TWNT-1 cells was seeded on the copolymer brush at 37 °C for adherence. By reducing the temperature to 20 °C, adhered HepG2 cells were selectively recovered with a purity of approximately 85% and normal activity. In addition, induced pluripotent stem (iPS) cell-derived hepatocytes adhered on the PVLA-b-PNIPAAm brush at 37 °C and detached from the copolymer brush at 20 °C, whereas the undifferentiated iPS cells did not adhere, indicating that the prepared PVLA-b-PNIPAAm brush could be utilized to separate hepatocyte differentiated and undifferentiated cells. These results indicated that the newly developed PVLA-b-PNIPAAm brush can separate hepatic cells from contaminant cells by temperature modulation, without affecting cell activity or modifying the cell surface. Thus, the copolymer brush is expected to be a useful separation tool for cell therapy and tissue engineering using hepatocytes.
Collapse
|
9
|
Comparison between the use of polyether ether ketone and stainless steel columns for ultrasonic-assisted extraction under various ultrasonic conditions. ULTRASONICS SONOCHEMISTRY 2022; 90:106125. [PMID: 36191369 PMCID: PMC9531288 DOI: 10.1016/j.ultsonch.2022.106125] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 06/10/2022] [Revised: 08/03/2022] [Accepted: 08/13/2022] [Indexed: 06/16/2023]
Abstract
The ultrasound-assisted extraction (UAE) was conducted using the stainless steel (SS) and polyether ether ketone (PEEK) columns and analyzed with high-performance liquid chromatography (HPLC) to understand the mechanism of ultrasound-assisted chromatography (UAC). Empty SS and PEEK columns were used to extract dyes from a fabric under identical conditions with several parameters including the initial ultrasonic bath temperatures (30 °C and 40 °C), ultrasound power intensities (0, 20, 40, 60, 80, and 100 %), ultrasound operation modes (normal and sweep), and ultrasound frequencies (25 kHz, 40 kHz, and 132 kHz) to compare their extraction capabilities. After 30 min of extraction, the amount of extract was determined by HPLC. The PEEK material was significantly affected by ultrasonic radiation compared to the SS material, especially at a higher temperature (40 °C), power intensity (100 %), and frequency (132 kHz) with sweep mode. At a maximum power density of 45 W/L, the extraction effectiveness ratio of PEEK to SS was in the range of 1.8 - 3.9 depending on the specific frequency, initial temperature, and with or without temperature control. The most optimal ultrasound frequencies, in terms of enhancing extraction effectiveness, are in the order of 132 kHz, 40 kHz, and 25 kHz. Unlike the SS material, the PEEK material was more affected by temperature and acoustic effects under identical conditions, especially at 132 kHz ultrasound frequency. In contrast, at lower frequencies of 40 kHz and 25 kHz, no significant differences in the acoustic effects were observed between the PEEK and SS materials. The findings of this study contribute to elucidating the roles of column materials in UAE and UAC.
Collapse
|
10
|
Temperature-modulated antibody drug separation using thermoresponsive mixed polymer brush-modified stationary phase. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2022.121750] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/17/2022]
|
11
|
Poly(N-isopropylacrylamide)-based temperature- and pH-responsive polymer materials for application in biomedical fields. Polym J 2022. [DOI: 10.1038/s41428-022-00687-z] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
|
12
|
Viral vector purification with thermoresponsive-anionic mixed polymer brush modified beads-packed column. Sep Purif Technol 2022. [DOI: 10.1016/j.seppur.2022.120445] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/19/2022]
|
13
|
Laser-Induced Graphene Superhydrophobic Surface Transition from Pinning to Rolling for Multiple Applications. SMALL METHODS 2022; 6:e2200096. [PMID: 35199498 DOI: 10.1002/smtd.202200096] [Citation(s) in RCA: 7] [Impact Index Per Article: 3.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/22/2022] [Indexed: 06/14/2023]
Abstract
The fabrication and applications of superhydrophobic surfaces (contact angle >150°, sliding angle <10°) have attracted worldwide interest with respect to materials and devices. In this work, the laser-induced graphene (LIG) superhydrophobic surface transition from pinning to rolling via an extremely simple solvent treatment of LIG in air is reported. By adding a certain solvent (e.g., ethanol) to the surface, the LIG superhydrophobic surface changes from pinning (sliding angle = 180°) to rolling (sliding angle <6°), which is attributed to the chemically changed surface properties and surface morphology of LIG. Three applications are demonstrated with the developed superhydrophobic LIG, including surface-enhanced Raman spectroscopy, water-oil separation, and anti-icing.
Collapse
|
14
|
Temperature-responsive mixed-mode column for the modulation of multiple interactions. Sci Rep 2022; 12:4434. [PMID: 35292748 PMCID: PMC8924202 DOI: 10.1038/s41598-022-08475-8] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/14/2021] [Accepted: 03/08/2022] [Indexed: 01/13/2023] Open
Abstract
In this study, mixed-mode chromatography columns have been investigated using multiple analyte interactions. A mixed-mode chromatography column was developed using poly(N-isopropylacrylamide) (PNIPAAm) brush-modified silica beads and poly(3-acrylamidopropyl trimethylammonium chloride) (PAPTAC) brush-modified silica beads. PNIPAAm brush-modified silica beads and PAPTAC brush-modified silica beads were prepared by atom transfer radical polymerization. The beads were then packed into a stainless-steel column in arbitrary compositions. The elution studies evaluated the column performance on hydrophobic, electrostatic, and therapeutic drug samples using steroids, adenosine nucleotide, and antiepileptic drugs as analytes, respectively. Steroids exhibited an increased retention time when the column temperature was increased. The retention of adenosine nucleotides increased with the increasing composition of the PAPTAC-modified beads in the column. The antiepileptic drugs were separated using the prepared mixed-mode columns. An effective separation of antiepileptic drugs was observed on a 10:1 PNIPAAm:PAPTAC column because the balance between the hydrophobic and electrostatic interactions with antiepileptic drugs was optimized for the bead composition. Oligonucleotides were also separated using mixed-mode columns through multiple hydrophobic and electrostatic interactions. These results demonstrate that the developed mixed-mode column can modulate multiple hydrophobic and electrostatic interactions by changing the column temperature and composition of the packed PNIPAAm and PAPTAC beads.
Collapse
|
15
|
Two-dimensional temperature-responsive chromatography using a poly(N-isopropylacrylamide) brush-modified stationary phase for effective therapeutic drug monitoring. Sci Rep 2022; 12:2653. [PMID: 35173260 PMCID: PMC8850448 DOI: 10.1038/s41598-022-06638-1] [Citation(s) in RCA: 4] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/24/2021] [Accepted: 02/03/2022] [Indexed: 11/09/2022] Open
Abstract
Therapeutic drug monitoring (TDM) is an effective pharmacological approach for controlling drug concentration in a patient's serum. Herein, a new two-dimensional chromatography system was developed using two poly(N-isopropylacrylamide) (PNIPAAm)-modified bead-packed columns for effective and safe drug monitoring. PNIPAAm-modified silica beads were prepared as packing materials using atom transfer radical polymerization of NIPAAm. The increase in the retention times of the drugs requiring TDM with increasing temperature, was attributed to enhanced hydrophobic interactions at elevated temperatures. The drugs and serum proteins were separated on the prepared column at 40 °C using an all-aqueous mobile phase. Differences in the hydrophobic interactions accounted for the elution of the serum proteins and drugs at short and long retention times, respectively, and a primary column was employed to separate the serum proteins and drugs. After eluting the serum proteins from the column, the drug was introduced into the secondary column, leading to a peak of its purified form and enabling determination of the drug concentration. Two-dimensional temperature-responsive chromatography can benefit TDM by allowing the drug concentration in the serum to be measured in all-aqueous mobile phases without sample preparation.
Collapse
|
16
|
Stationary Phases for Green Liquid Chromatography. MATERIALS 2022; 15:ma15020419. [PMID: 35057141 PMCID: PMC8778826 DOI: 10.3390/ma15020419] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/09/2021] [Revised: 12/14/2021] [Accepted: 12/30/2021] [Indexed: 01/27/2023]
Abstract
Industrial research, including pharmaceutical research, is increasingly using liquid chromatography techniques. This involves the production of large quantities of hazardous and toxic organic waste. Therefore, it is essential at this point to focus interest on solutions proposed by so-called “green chemistry”. One such solution is the search for new methods or the use of new materials that will reduce waste. One of the most promising ideas is to perform chromatographic separation using pure water, without organic solvents, as a mobile phase. Such an approach requires novel stationary phases or specific chromatographic conditions, such as an elevated separation temperature. The following review paper aims to gather information on stationary phases used for separation under purely aqueous conditions at various temperatures.
Collapse
|
17
|
Temperature responsive chromatography for therapeutic drug monitoring with an aqueous mobile phase. Sci Rep 2021; 11:23508. [PMID: 34873248 PMCID: PMC8648775 DOI: 10.1038/s41598-021-02998-2] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/02/2021] [Accepted: 11/15/2021] [Indexed: 11/30/2022] Open
Abstract
Therapeutic drug monitoring is a key technology for effective pharmacological treatment. In the present study, a temperature-responsive chromatography column was developed for safe and simple therapeutic drug monitoring without the use of organic solvents. Poly(N-isopropylacrylamide) (PNIPAAm) hydrogel-modified silica beads were prepared via a condensation reaction and radical polymerization. The temperature-dependent elution behavior of the drugs was observed using a PNIPAAm-modified silica-bead packed column and an all-aqueous mobile phase. Sharp peaks with reproducible retention times were observed at temperatures of 30 °C or 40 °C because the PNIPAAm hydrogel on the silica beads shrinks at these temperatures, limiting drug diffusion into the PNIPAAm hydrogel layer. The elution behavior of the sample from the prepared column was examined using a mixture of serum and model drugs. The serum and drugs were separated on the column at 30 °C or 40 °C, and the concentration of the eluted drug was obtained using the calibration curve. The results show that the prepared chromatography column would be useful for therapeutic drug monitoring because the drug concentration in serum can be measured without using organic solvents in the mobile phase and without any need for sample preparation.
Collapse
|
18
|
Investigation of the potential of mixed solvent mobile phases in temperature-responsive liquid chromatography (TRLC). Analyst 2021; 146:6990-6996. [PMID: 34668892 DOI: 10.1039/d1an01684a] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
Temperature-responsive liquid chromatography (TRLC) allows for extensive retention and selectivity tuning through temperature in HPLC. This is mainly achieved through the use of a stationary phases comprising of a temperature-responsive polymer which undergoes a reversible change from hydrophilic to hydrophobic behaviour upon increasing the temperature. The approach can allow for reversed phase type separations to be achieved with purely aqueous mobile phases, whereby the retention is controlled through temperature instead of mobile phase composition. Despite the promising nature of such form of retention control under isocratic mobile phase conditions, TRLC can suffer from excessive retention of highly apolar solutes even at lower column temperatures whereby the polymer is considered hydrophilic. This is related both to a residual apolarity of the polymer chain and due to the high log P's and low water solubility of higly apolar compounds. While it was known that elution in TRLC doesn't necessarily has to be performed under purely aqueous conditions and that the use of organic co-solvents to the water is possible, the impact thereof on the temperature responsive behaviour itself had not yet been investigated in a systematic way. Therefore in this work the advantages and drawbacks of the use of the organic co-solvents methanol and acetonitrile in TRLC is assessed on two types of temperature reponsive phases: poly-N-N-propylacrylamide (PNNPAAm) and poly-N-isopropylacrylamide (PNIPAAm). The influence of organic co-solvents is investigated with two representative test mixtures (comprising 4 parabens and 5 apolar steroids).
Collapse
|
19
|
Thermally-modulated cell separation columns using a thermoresponsive block copolymer brush as a packing material for the purification of mesenchymal stem cells. Biomater Sci 2021; 9:7054-7064. [PMID: 34296234 DOI: 10.1039/d1bm00708d] [Citation(s) in RCA: 14] [Impact Index Per Article: 4.7] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/31/2022]
Abstract
Cell therapy using mesenchymal stem cells (MSCs) is used as effective regenerative treatment. Cell therapy requires effective cell separation without cell modification and cellular activity reduction. In this study, we developed a temperature-modulated mesenchymal stem cell separation column. A temperature-responsive cationic block copolymer, poly(N,N-dimethylaminopropylacrylamide)-b-poly(N-isopropylacrylamide)(PDMAPAAm-b-PNIPAAm) brush with various cationic copolymer compositions, was grafted onto silica beads via two-step atom transfer radical polymerization. Using the packed beads, the elution behavior of the MSCs was observed. At 37 °C, the MSCs were adsorbed onto the column via both hydrophobic and electrostatic interactions with the PNIPAAm and PDMAPAAm segments of the copolymer brush, respectively. By reducing the temperature to 4 °C, the adsorbed MSCs were eluted from the column by reducing the hydrophobic and electrostatic interactions attributed to the hydration and extension of the PNIPAAm segment of the block copolymer brush. From the temperature-modulated adsorption and elution behavior of MSCs, a suitable DMAPAAm composition of the block copolymer brush was determined. Using the column, a mixture of MSC and BM-CD34+ cells was separated by simply changing the column temperature. The column was used to purify the MSCs, with purities of 78.2%, via a temperature change from 37 °C to 4 °C. Additionally, the cellular activity of the MSCs was retained throughout the column separation step. Overall, the obtained results show that the developed column is useful for MSC separation without cell modification and cellular activity reduction.
Collapse
|
20
|
Temperature-responsive spin column for sample preparation using an all-aqueous eluent. Anal Chim Acta 2021; 1179:338806. [PMID: 34535268 DOI: 10.1016/j.aca.2021.338806] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/24/2021] [Revised: 05/31/2021] [Accepted: 06/24/2021] [Indexed: 11/21/2022]
Abstract
We present a temperature-responsive spin column using an all-aqueous eluent. The method is intended as a simple sample preparation method for protein removal from serum, which is required for serum drug analysis. As packing materials for the spin column, we prepared two types of silica beads via surface-initiated radical polymerization. The large beads (diameter, 40-63 μm) were grafted with a temperature-responsive cationic copolymer, poly(N-isopropylacrylamide-co-N,N-dimethylaminopropyl acrylamide-co-n-butyl methacrylate) (P(NIPAAm-co-DMAPAAm-co-BMA)), and the small beads (diameter, 5 μm) were grafted with a temperature-responsive hydrophobic copolymer, P(NIPAAm-co-BMA). The beads were packed into the spin column as a double layer: P(NIPAAm-co-BMA) silica beads on the bottom and P(NIPAAm-co-DMAPAAm-co-BMA) silica beads on the top. The sample purification efficacy of the prepared spin column was evaluated on a model sample analyte (the antifungal drug voriconazole mixed with blood serum proteins). At 40 °C, the serum proteins and voriconazole were adsorbed on the prepared spin column via hydrophobic and electrostatic interactions. When the temperature was decreased to 4 °C, the adsorbed voriconazole was eluted from the column with the pure water eluent, while the serum proteins remained in the column. This temperature-responsive spin column realizes sample preparation simply by changing the temperature.
Collapse
|
21
|
Thermoresponsive interfaces obtained using poly(N-isopropylacrylamide)-based copolymer for bioseparation and tissue engineering applications. Adv Colloid Interface Sci 2021; 295:102487. [PMID: 34314989 DOI: 10.1016/j.cis.2021.102487] [Citation(s) in RCA: 21] [Impact Index Per Article: 7.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 07/09/2021] [Accepted: 07/10/2021] [Indexed: 12/11/2022]
Abstract
Poly(N-isopropylacrylamide) (PNIPAAm) is the most well-known and widely used stimuli-responsive polymer in the biomedical field owing to its ability to undergo temperature-dependent hydration and dehydration with temperature variations, causing hydrophilic and hydrophobic alterations. This temperature-dependent property of PNIPAAm provides functionality to interfaces containing PNIPAAm. Notably, the hydrophilic and hydrophobic alterations caused by the change in the temperature-responsive property of PNIPAAm-modified interfaces induce temperature-modulated interactions with biomolecules, proteins, and cells. This intrinsic property of PNIPAAm can be effectively used in various biomedical applications, particularly in bioseparation and tissue engineering applications, owing to the functionality of PNIPAAm-modified interfaces based on the temperature modulation of the interaction between PNIPAAm-modified interfaces and biomolecules and cells. This review focuses on PNIPAAm-modified interfaces in terms of preparation method, properties, and their applications. Advances in PNIPAAm-modified interfaces for existing and developing applications are also summarized.
Collapse
|
22
|
Anion species-triggered antibody separation system utilizing a thermo-responsive polymer column under optimized constant temperature. Colloids Surf B Biointerfaces 2021; 205:111890. [DOI: 10.1016/j.colsurfb.2021.111890] [Citation(s) in RCA: 9] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/02/2021] [Revised: 04/29/2021] [Accepted: 05/28/2021] [Indexed: 01/08/2023]
|
23
|
Preparation, Properties and Cell Biocompatibility of Room Temperature LCST-Hydrogels Based on Thermoresponsive PEO Stars. Gels 2021; 7:gels7030084. [PMID: 34287296 PMCID: PMC8293143 DOI: 10.3390/gels7030084] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/02/2021] [Revised: 06/28/2021] [Accepted: 07/02/2021] [Indexed: 12/23/2022] Open
Abstract
A series of star and linear polymers based on a poly(ethylene oxide) core and poly(diethylene glycol ethyl ether acrylate) outer arms were synthesised by atom-transfer radical polymerization. The polydispersity of the polymers were low, showing good control of initiation and growth. They all showed lower critical solution (LCST) behaviour, and at 30% concentration most gelled at or below room temperature. The behaviour depended on the number and length of the arms, with the polymers with longer arms gelling at a lower temperature and producing stiffer gels. The shear modulus of the gels varied between 1 and 48 kPa, with the gelling temperature varying between 16 and 23 °C. Attempted cell cultures with the polymers proved unsuccessful, which was determined to be due to the high concentration of polymers needed for gelling.
Collapse
|
24
|
Effect of pore diameter on the elution behavior of analytes from thermoresponsive polymer grafted beads packed columns. Sci Rep 2021; 11:9976. [PMID: 33976250 PMCID: PMC8113370 DOI: 10.1038/s41598-021-89165-9] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/21/2021] [Accepted: 04/21/2021] [Indexed: 02/07/2023] Open
Abstract
Temperature-responsive chromatography using thermoresponsive polymers is innovative and can control analyte retention via column temperature. Analyte elution behavior in this type of chromatography depends on the modified thermoresponsive polymer and the structure of the base materials. In the present study, we examine the effect of the pore diameter of silica beads on analyte elution behavior in temperature-responsive chromatography. Poly(N-isopropylacrylamide-co-n-butyl methacrylate) hydrogel was applied to beads of various pore sizes: 7, 12, and 30 nm. Almost the same amount of copolymer hydrogel was applied to all beads, indicating that the efficiency of copolymer modification was independent of pore size. Analyte retention on prepared beads in a packed column was observed using steroids, benzodiazepines, and barbiturates as analytes. Analyte retention times increased with temperature on packed columns of 12- and 30-nm beads, whereas the column packed with 7-nm beads exhibited decreased retention times with increasing temperature. The difference in analyte elution behavior among the various pore sizes was attributed to analyte diffusion into the bead pores. These results demonstrate that bead pore diameter determines temperature-dependent elution behavior.
Collapse
|
25
|
Effective Separation for New Therapeutic Modalities Utilizing Temperature-responsive Chromatography. ANAL SCI 2021; 37:651-660. [PMID: 33518586 DOI: 10.2116/analsci.20scr09] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/27/2020] [Accepted: 01/22/2021] [Indexed: 08/09/2023]
Abstract
In recent years, drug discovery and therapeutics trends have shifted from a focus on small-molecule compounds to biopharmaceuticals, genes, cell therapy, and regenerative medicine. Therefore, new approaches and technologies must be developed to respond to these changes in medical care. To achieve this, we applied a temperature-responsive separation system to purify a variety of proteins and cells. We developed a temperature-responsive chromatography technique based on a poly(N-isopropylacrylamide) (PNIPAAm)-grafted stationary phase. This method may be applied to various types of protein and cell separation applications by optimizing the properties of the modified polymers used in this system. Therefore, the developed temperature-responsive HPLC columns and temperature-responsive solid-phase extraction (TR-SPE) columns can be an effective separation tool for new therapeutic modalities such as monoclonal antibodies, nucleic acid drugs, and cells.
Collapse
|
26
|
Towards spatial comprehensive three-dimensional liquid chromatography: A tutorial review. Anal Chim Acta 2021; 1148:238157. [DOI: 10.1016/j.aca.2020.12.032] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 12/15/2020] [Accepted: 12/16/2020] [Indexed: 01/19/2023]
|
27
|
UV cross-linked smart microgel membranes as free-standing diffusion barriers and nanoparticle bearing catalytic films. RSC Adv 2021; 11:22014-22024. [PMID: 35480797 PMCID: PMC9036384 DOI: 10.1039/d1ra03528b] [Citation(s) in RCA: 7] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/06/2021] [Accepted: 06/15/2021] [Indexed: 01/04/2023] Open
Abstract
In this study we use poly(N-isopropylacrylamide) (PNIPAM) based copolymer microgels to create free-standing, transferable, thermoresponsive membranes. The microgels are synthesized by copolymerization of NIPAM with 2-hydroxy-4-(methacryloyloxy)–benzophenone (HMABP) and spin-coated on Si wafers. After subsequent cross-linking by UV-irradiation, the formed layers easily detach from the supporting material. We obtain free standing microgel membranes with lateral extensions of several millimetres and an average layer thickness of a few hundred nanometres. They can be transferred to other substrates. As one example for potential applications we investigate the temperature dependent ion transport through the membranes via resistance measurements revealing a sharp reversible increase in resistance when the lower critical solution temperature of the copolymer microgels is reached. In addition, prior to cross-linking, the microgels can be decorated with silver nanoparticles and cross-linked afterwards. Such free-standing nanoparticle hybrid membranes are then used as catalytic systems for the reduction of 4-nitrophenol, which is monitored by UV/Vis spectroscopy. Cross-linkable microgels are synthesized by copolymerization of NIPAM with 2-hydroxy-4-(methacryloyloxy)–benzophenone (HMABP) and are subsequently UV-cross-linked to obtain smart membranes exhibiting switchable resistance.![]()
Collapse
|
28
|
Selective capture and non-invasive release of cells using a thermoresponsive polymer brush with affinity peptides. Biomater Sci 2021; 9:663-674. [DOI: 10.1039/d0bm01453b] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023]
Abstract
Thermoresponsive block copolymer brush with cell affinity peptides was prepared via two steps of ATRP and subsequent click reaction. The prepared polymer brush can purify cells with high selectivity by simply changing temperature.
Collapse
|
29
|
Formation and Stability of Smooth Thin Films with Soft Microgels Made of Poly( N-Isopropylacrylamide) and Poly(Acrylic Acid). Polymers (Basel) 2020; 12:E2638. [PMID: 33182647 PMCID: PMC7697199 DOI: 10.3390/polym12112638] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2020] [Revised: 10/29/2020] [Accepted: 11/05/2020] [Indexed: 11/30/2022] Open
Abstract
In this work, soft microgels of Poly(N-Isopropylacrylamide) (PNIPAm) at two different sizes and of interpenetrated polymer network (IPN) composed of PNIPAm and Poly(Acrylic Acid) (PAAc) were synthesized. Then, solutions of these different types of microgels have been spin-coated on glass substrates with different degrees of hydrophobicity. PNIPAm particles with a larger diameter form either patches or a continuous layer, where individual particles are still distinct, depending on the dispersion concentration and spin speed. On the other, PNIPAm particles with a smaller diameter and IPN particles form a continuous and smooth film, with a thickness depending on the dispersion concentration and spin-speed. The difference in morphology observed can be explained if one considers that the microgels may behave as colloidal particles or macromolecules, depending on their size and composition. Additionally, the microgel size and composition can also affect the stability of the depositions when rinsed in water. In particular, we find that the smooth and continuous films show a stimuli-dependent stability on parameters such as temperature and pH, while large particle layers are stable under any condition except on hydrophilic glass by washing at 50 °C.
Collapse
|
30
|
Temperature-responsive chromatography for bioseparations: A review. Anal Chim Acta 2020; 1138:191-212. [DOI: 10.1016/j.aca.2020.07.075] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/01/2020] [Revised: 07/29/2020] [Accepted: 07/30/2020] [Indexed: 02/07/2023]
|
31
|
Thermoresponsive Cationic Block Copolymer Brushes for Temperature‐Modulated Stem Cell Separation. Macromol Rapid Commun 2020; 41:e2000308. [DOI: 10.1002/marc.202000308] [Citation(s) in RCA: 19] [Impact Index Per Article: 4.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/04/2020] [Revised: 08/03/2020] [Indexed: 12/20/2022]
|
32
|
Antibody drug separation using thermoresponsive anionic polymer brush modified beads with optimised electrostatic and hydrophobic interactions. Sci Rep 2020; 10:11896. [PMID: 32719404 PMCID: PMC7385495 DOI: 10.1038/s41598-020-68707-7] [Citation(s) in RCA: 24] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/30/2020] [Accepted: 06/09/2020] [Indexed: 12/15/2022] Open
Abstract
Antibody drugs play an important role in biopharmaceuticals, because of the specificity for target biomolecules and reduction of side effects. Thus, separation and analysis techniques for these antibody drugs have increased in importance. In the present study, we develop functional chromatography matrices for antibody drug separation and analysis. Three types of polymers, poly(N-isopropylacrylamide (NIPAAm)-co-2-acrylamido-2-methylpropanesulfonic acid (AMPS)-co-N-phenyl acrylamide (PhAAm)), P(NIPAAm-co-AMPS-co-n-butyl methacrylate (BMA)), and P(NIPAAm-co-AMPS-co-tert-butylacrylamide (tBAAm)), were modified on silica beads through atom transfer radical polymerisation. Rituximab elution profiles were observed using the prepared beads-packed column. Rituximab adsorption at high temperature and elution at low temperature from the column were observed, as a result of the temperature-modulated electrostatic and hydrophobic interactions. Using the column, rituximab purification from contaminants was performed simply by changing the temperature. Additionally, three types of antibody drugs were separated using the column through temperature-modulated hydrophobic and electrostatic interactions. These results demonstrate that the temperature-responsive column can be applied for the separation and analysis of biopharmaceuticals through a simple control of the column temperature.
Collapse
|
33
|
Exploration of the Selectivity and Retention Behavior of Alternative Polyacrylamides in Temperature Responsive Liquid Chromatography. Anal Chem 2020; 92:9815-9822. [PMID: 32598128 DOI: 10.1021/acs.analchem.0c01321] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Temperature responsive liquid chromatography (TRLC) allows for separation of organic solutes in purely aqueous mobile phases whereby retention is controlled through temperature. The vast majority of the work has thus far been performed on poly[N-isopropylacrylamide] (PNIPAAm)-based columns, while the performance of other temperature responsive polymers has rarely been compared under identical conditions. Therefore, in this work, two novel TRLC phases based on poly[N-n-propylacrylamide] (PNNPAAm) and poly[N,N-diethylacrylamide] (PDEAAm) are reported and compared to the state of the art PNIPAAm based column. Optimal comparison is thereby obtained by the use of controlled radical polymerizations, identical molecular weights, and by maximizing carbon loads on the silica supporting material. Analysis of identical test mixtures of homologue series and pharmaceutical samples revealed that PNNPAAm performs in a similar way as PNIPAAm while offering enhanced retention and a shift of the useable temperature range toward lower temperatures. PDEAAm offers a range of novel possibilities as it depicts a different selectivity, allowing for enhanced resolution in TRLC in, for example, coupled column systems. Reduced plate heights of 3 could be obtained on the homemade columns, offering the promise for reasonable column efficiencies in TRLC despite the use of bulky polymers as stationary phases in HPLC.
Collapse
|
34
|
Simultaneous analysis of multiple oligonucleotides by temperature-responsive chromatography using a poly(N-isopropylacrylamide)-based stationary phase. Anal Bioanal Chem 2020; 412:5341-5351. [PMID: 32529301 PMCID: PMC7387324 DOI: 10.1007/s00216-020-02749-8] [Citation(s) in RCA: 12] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Abstract] [Key Words] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/22/2020] [Revised: 05/21/2020] [Accepted: 05/29/2020] [Indexed: 12/25/2022]
Abstract
Oligonucleotide therapeutics have contributed remarkably to healthcare, being well suited for the treatment of intractable diseases that are difficult to approach using conventional drug modalities. However, as common techniques of oligonucleotide analysis rely on reversed-phase or ion-exchange liquid chromatography and thus employ toxic organic solvents and/or ion-pairing reagents, better alternatives are highly sought after. Poly(N-isopropylacrylamide) (PNIPAAm) is widely used in temperature-responsive chromatography (TRC), which relies on column temperature variation to control the physical properties of the stationary phase and, unlike conventional reversed-phase liquid chromatography, avoids the use of toxic organic solvents and complicated gradient methods. Herein, PNIPAAm copolymer hydrogel-modified silica beads were used for the simultaneous analysis of multiple synthetic oligonucleotides by TRC to recognize differences in the length of single nucleotides, single bases, and the number of phosphorothioated sites. Temperature-responsive elution was observed in all cases. Each separation of all combinations of multiple oligonucleotides was better at higher temperatures above the lower critical solution temperature and was performed without the use of organic solvents and gradient methods. In the case of multiply phosphorothioated oligonucleotides, good separation was achieved using an aqueous solvent and isocratic elution in the absence of ion-pairing reagents. Thus, the developed procedure was concluded to be well suited for oligonucleotide analysis. Graphical abstract ![]()
Collapse
|
35
|
Green analytical method for the simultaneous analysis of cytochrome P450 probe substrates by poly(N-isopropylacrylamide)-based temperature-responsive chromatography. Sci Rep 2020; 10:8828. [PMID: 32483226 PMCID: PMC7264224 DOI: 10.1038/s41598-020-65270-z] [Citation(s) in RCA: 11] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/11/2020] [Accepted: 04/28/2020] [Indexed: 02/07/2023] Open
Abstract
High-performance liquid chromatography (HPLC) is the most common analytical method practiced in various fields and used for analysis of almost all drug compounds in the pharmaceutical industries. During drug development, an evaluation of potential drug interaction with cytochrome P450 (CYP) is essential. A "cocktail" approach is often used in drug development to evaluate the effect of a drug candidate on multiple CYP enzymes in a single experiment. So far, simultaneous analysis of multiple CYP substrates, which have greatly different structure and physicochemical properties, has required organic solvents and mobile phase gradient methods. However, despite the recent emphasis on environmental protection, analytical methods that use only aqueous solvents without the use of organic solvents for separation have not been studied well. This study sought to develop the simultaneous analysis of multiple CYP substrates by using poly(N-isopropylacrylamide) (PNIPAAm)-based temperature-responsive chromatography with only aqueous solvents and isocratic methods. Good separation of multiple CYP substrates was achieved without using organic solvents and any gradient methods by temperature-responsive chromatography utilizing a P(NIPAAm-co-n-butyl methacrylate (BMA))- and P(NIPAAm-co-N-acryloyl L-tryptophan methyl ester (L-Trp-OMe))-grafted silica column. Overall, PNIPAAm-based temperature-responsive chromatography represents a remarkably simple, versatile, and environmentally friendly bioanalytical method for CYP substrates and their metabolites.
Collapse
|
36
|
Temperature and pH-Dependent Response of Poly(Acrylic Acid) and Poly(Acrylic Acid- co-Methyl Acrylate) in Highly Concentrated Potassium Chloride Aqueous Solutions. Polymers (Basel) 2020; 12:polym12020486. [PMID: 32098216 PMCID: PMC7077713 DOI: 10.3390/polym12020486] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/15/2020] [Revised: 02/13/2020] [Accepted: 02/17/2020] [Indexed: 12/05/2022] Open
Abstract
In this study, the phase transition phenomena of linear poly(acrylic acid) (PAA) and linear or star-shaped poly(acrylic acid-co-methyl acrylate) (P(AA-co-MA)) in highly concentrated KCl solutions were investigated. The effects of polymer molecular weight, topology, and composition on their phase transition behavior in solution were investigated. The cloud point temperature (TCP) of polymers drastically increased as the KCl concentration (CKCl) and solution pH increased. CKCl strongly influenced the temperature range at which the phase transition of PAA occurred: CKCl of 1.0–2.2 M allowed the phase transition to occur between 30 and 75 °C. Unfortunately, at CKCl above 2.6 M, the TCP of PAA was too high to theoretically trigger the crystallization of KCl. The addition of hydrophobic methyl acrylate moieties decreased the TCP into a temperature region where KCl crystallization could occur. Additionally, the hydrodynamic diameters (Dh) and zeta potentials of commercial PAA samples were examined at room temperature and at their TCP using dynamic light scattering. The salt concentration (from 1 to 3 M) did not impact the hydrodynamic diameter of the molecules. Dh values were 1500 and 15 nm at room temperature and at TCP, respectively.
Collapse
|
37
|
|
38
|
Thermoresponsive polymers and their biomedical application in tissue engineering - a review. J Mater Chem B 2020; 8:607-628. [PMID: 31939978 DOI: 10.1039/c9tb02052g] [Citation(s) in RCA: 151] [Impact Index Per Article: 37.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/20/2022]
Abstract
Thermoresponsive polymers hold great potential in the biomedical field, since they enable the fabrication of cell sheets, in situ drug delivery and 3D-printing under physiological conditions. In this review we provide an overview of several thermoresponsive polymers and their application, with focus on poly(N-isopropylacrylamide)-surfaces for cell sheet engineering. Basic knowledge of important processes like protein adsorption on surfaces and cell adhesion is provided. For different thermoresponsive polymers, namely PNIPAm, Pluronics, elastin-like polypeptides (ELP) and poly(N-vinylcaprolactam) (PNVCL), synthesis and basic chemical and physical properties have been described and the mechanism of their thermoresponsive behavior highlighted. Fabrication methods of thermoresponsive surfaces have been discussed, focusing on PNIPAm, and describing several methods in detail. The latter part of this review is dedicated to the application of the thermoresponsive polymers and with regard to cell sheet engineering, the process of temperature-dependent cell sheet detachment is explained. We provide insight into several applications of PNIPAm surfaces in cell sheet engineering. For Pluronics, ELP and PNVCL we show their application in the field of drug delivery and tissue engineering. We conclude, that research of thermoresponsive polymers has made big progress in recent years, especially for PNIPAm since the 1990s. However, manifold research possibilities, e.g. in surface fabrication and 3D-printing and further translational applications are conceivable in near future.
Collapse
|
39
|
Enhanced mechanical properties and cell separation with thermal control of PIPAAm-brushed polymer-blend microfibers. J Mater Chem B 2020; 8:6017-6026. [DOI: 10.1039/d0tb00972e] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/14/2022]
Abstract
Thermoresponsive microfibers with enhanced mechanical properties for temperature-modulated cell separation were developed by electrospinning of blending PVBC and PBMA, and by subsequently modifying the microfibers with PIPAAm via ATRP.
Collapse
|
40
|
Thermoresponsive anionic copolymer brush-grafted surfaces for cell separation. Colloids Surf B Biointerfaces 2020; 185:110565. [DOI: 10.1016/j.colsurfb.2019.110565] [Citation(s) in RCA: 22] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/26/2019] [Revised: 09/07/2019] [Accepted: 10/04/2019] [Indexed: 12/15/2022]
|
41
|
Characteristic differences of cell sheets composed of mesenchymal stem cells with different tissue origins. Regen Ther 2019; 11:34-40. [PMID: 31193157 PMCID: PMC6517796 DOI: 10.1016/j.reth.2019.01.002] [Citation(s) in RCA: 27] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 12/20/2018] [Revised: 12/28/2018] [Accepted: 01/06/2019] [Indexed: 12/13/2022] Open
Abstract
INTRODUCTION Stem cell therapy with mesenchymal stem cells (MSCs) has been widely used in many clinical trials, and therapy with MSC sheets shows promise for patients. However, there are few reports characterizing MSC sheets. In the present study, the properties of MSC sheets derived from bone marrow, adipose tissue, and umbilical cord were evaluated. METHODS Cell sheets were fabricated with MSCs from different tissue origins in temperature-responsive cell culture dishes with and without pre-coating of fetal bovine serum (FBS). MSC adhesion behavior in the culture dish was observed. Secretion of cytokines related to cell proliferation and immune regulation from MSC sheets was investigated by ELISA. The adhesion properties of the MSC sheets were investigated by time-lapse microscopy. RESULTS Different cell adhesion and proliferation rates in temperature-responsive cell culture dishes were observed among the three types of MSCs. FBS pre-coating of the dishes enhanced cell attachment and proliferation in all cell types. Harvested cell sheets showed high attachment capacity to tissue culture polystyrene dish surfaces. CONCLUSIONS MSC sheets can be fabricated from MSCs from different tissue origins using temperature-responsive cell culture dishes. The fabricated MSC sheets could be useful in cell transplantation therapies by choosing appropriate types of MSCs that secrete therapeutic cytokines for the targeted diseases.
Collapse
|
42
|
Controlled-Height Brush Polymer Patterns via Surface-Initiated Thiol-Methacrylate Photopolymerizations. ACS Macro Lett 2019; 8:1474-1478. [PMID: 35651178 DOI: 10.1021/acsmacrolett.9b00699] [Citation(s) in RCA: 14] [Impact Index Per Article: 2.8] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/27/2022]
Abstract
Here, we show that the surface-initiated thiol-(meth)acrylate polymerization can be used to create brush polymer patterns with precise control over the feature height at each microscale pixel. The reaction was studied using a printer where a digital micromirror device controls light delivery to the surface, so multiple reaction conditions can be examined in each print. The resulting increases in experimental throughput and precision were demonstrated by studying systematically the effect of photocatalyst, photoinitiator, and light intensity on feature growth rate. In addition to demonstrating the utility of surface-initiated thiol-(meth)acrylate chemistry for creating complex brush polymer patterns, this work describes an improved and high-throughput approach for studying grafted-from photopolymerizations.
Collapse
|
43
|
Preparation of thermoresponsive nanoparticles exhibiting biomolecule recognition ability via atom transfer radical dispersion polymerization. Colloids Surf B Biointerfaces 2019; 183:110370. [DOI: 10.1016/j.colsurfb.2019.110370] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/21/2019] [Revised: 06/20/2019] [Accepted: 07/14/2019] [Indexed: 10/26/2022]
|
44
|
Temperature-responsive mixed-mode column containing temperature-responsive polymer-modified beads and anionic polymer-modified beads. Anal Chim Acta 2019; 1079:220-229. [DOI: 10.1016/j.aca.2019.06.010] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/27/2019] [Revised: 05/18/2019] [Accepted: 06/04/2019] [Indexed: 10/26/2022]
|
45
|
Mixed polymer brush as a functional ligand of silica beads for temperature-modulated hydrophobic and electrostatic interactions. Anal Chim Acta 2019; 1095:1-13. [PMID: 31864610 DOI: 10.1016/j.aca.2019.10.058] [Citation(s) in RCA: 21] [Impact Index Per Article: 4.2] [Reference Citation Analysis] [Abstract] [Key Words] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/11/2019] [Revised: 10/21/2019] [Accepted: 10/24/2019] [Indexed: 11/23/2022]
Abstract
We developed a mixed polymer brush, which consists of temperature-responsive polymer and cationic polymer modified beads as functional chromatographic matrices, for temperature-modulated multiple hydrophobic and electrostatic interactions. The mixed polymer brush was modified on silica beads through the combination of reversible addition-fragmentation chain transfer (RAFT) polymerization of N,N-dimethylaminopropyl acrylamide (DMAPAAm) and surface initiated atom transfer radical polymerization (ATRP) of N-isopropylacrylamide (NIPAAm). Zeta potential measurement of the mixed polymer brush revealed that the zeta potential increased with increasing temperature, which was attributed to the exposed PDMAPAAm on the beads arising from the shrinking of PNIPAAm upon increasing the temperature. The prepared beads were used as the packing material of high performance liquid chromatography (HPLC) columns, and the elution behavior of steroids, adenosine nucleotides, and proteins through the column was observed. The retention time of steroids increased with increasing the column temperature because of the dehydration of PNIPAAm in the mixed polymer brush. Adenosine nucleotides were also retained by the columns, which was attributed to the electrostatic interaction with PDMAPAAm in the mixed polymer brush. Several proteins were adsorbed on the column at elevated temperatures because of the enhanced electrostatic interaction of exposed PDMAPAAm and the enhanced hydrophobic interaction resulting from the dehydration of PNIPAAm. By exploiting this unique property, mixtures of proteins could be separated by simply changing the column temperature. These results indicate that the developed mixed polymer brush modified beads would be useful as functional chromatographic packing matrices for thermally-modulated multiple hydrophobic and electrostatic interactions.
Collapse
|
46
|
Combination of Three Functionalized Temperature-Sensitive Chromatographic Materials for Serum Protein Analysis. Molecules 2019; 24:E2626. [PMID: 31330945 PMCID: PMC6680567 DOI: 10.3390/molecules24142626] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 05/29/2019] [Revised: 07/15/2019] [Accepted: 07/18/2019] [Indexed: 12/15/2022] Open
Abstract
We have developed a methodology to capture acidic proteins, alkaline proteins, and glycoproteins separately in mouse serum using a combination of three functionalized temperature-responsive chromatographic stationary phases. The temperature-responsive polymer poly(N-isopropylacrylamide) was attached to the stationary phase, silica. The three temperature-responsive chromatographic stationary phase materials were prepared by reversible addition-fragmentation chain transfer polymerization. Alkaline, acidic, and boric acid functional groups were introduced to capture acidic proteins, alkaline proteins, and glycoproteins, respectively. The protein enrichment and release properties of the materials were examined using the acidic protein, bovine serum albumin; the alkaline protein, protamine; and the glycoprotein, horseradish peroxidase. Finally, the three materials were used to analyze mouse serum. Without switching the mobile phase, the capture and separation of mouse serum was achieved by the combination of three temperature-responsive chromatographic stationary phase materials. On the whole, 313 proteins were identified successfully. The number of different proteins identified using the new method was 1.46 times greater than the number of proteins that has been identified without applying this method. To our knowledge, this method is the first combinatorial use of three functionalized temperature-responsive chromatographic stationary phase silica materials to separate proteins in mouse serum.
Collapse
|
47
|
Liposomes with temperature-responsive reversible surface properties. Colloids Surf B Biointerfaces 2019; 176:309-316. [DOI: 10.1016/j.colsurfb.2019.01.007] [Citation(s) in RCA: 19] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/11/2018] [Revised: 12/28/2018] [Accepted: 01/02/2019] [Indexed: 10/27/2022]
|
48
|
Investigations into the interaction thermodynamics of TRAP-related peptides with a temperature-responsive polymer-bonded porous silica stationary phase. Anal Chim Acta X 2019; 1:100008. [PMID: 33117975 PMCID: PMC7587034 DOI: 10.1016/j.acax.2019.100008] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/24/2022] Open
Abstract
The interaction thermodynamics of the thrombin receptor agonistic peptide (TRAP-1), H-Ser-Phe-Leu-Leu-Arg-Asn-Pro-OH, and a set of alanine scan substitution peptides, have been investigated with an n-octadecylacrylic polymer-bonded porous silica (Sil-ODA18) and water-acetonitrile mobile phases at temperatures ranging from 5 to 80 °C in 5 °C increments. The retention of these peptides on the Sil-ODA18 stationary phase decreased as the water content in the mobile phase was lowered from 80% (v/v) to ca. 45% (v/v) and reached a minimum value for each peptide at a specific water-acetonitrile composition. Further decreases in the water content of the mobile phase led to increased retention. The magnitude of the changes in enthalpy of interaction, Δ H a s s o c 0 , changes in entropy of interaction, Δ S a s s o c 0 , and changes in heat capacity, Δ C p 0 , were found to be dependent on the molecular properties of the mobile phase, the temperature, the structure/mobility of the stationary phase, and the conformation and solvation state of the peptides. With water-rich mobile phases, the retention behaviour of the TRAP analogues was dominated by enthalpic processes, consistent with the participation of strong hydrogen bonding effects, but became dominated by entropic effects with acetonitrile-rich mobile phases as the temperature was increased. These changes in the retention behaviour of these TRAP peptides are consistent with the generation of water or acetonitrile clusters in the mobile phase depending on the volume fractions of the organic solvent as the Sil-ODA18 stationary phase transitions from its crystalline to its isotropic state.
Collapse
|
49
|
Temperature-modulated cell-separation column using temperature-responsive cationic copolymer hydrogel-modified silica beads. Colloids Surf B Biointerfaces 2019; 178:253-262. [PMID: 30875584 DOI: 10.1016/j.colsurfb.2019.02.057] [Citation(s) in RCA: 22] [Impact Index Per Article: 4.4] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/19/2018] [Revised: 02/05/2019] [Accepted: 02/28/2019] [Indexed: 01/06/2023]
Abstract
There is strong demand for cell separation methods that do not decrease cell activity or modify cell surfaces. Here, new temperature-modulated cell-separation columns not requiring cell-surface premodification are described. The columns were packed with temperature-responsive cationic polymer hydrogel-modified silica beads. Poly(N-isopropylacrylamide-co-n-butyl methacrylate-co-N,N-dimethylaminopropyl acrylamide) hydrogels with various cationic moieties were attached to silica-bead surfaces by radical polymerization using N,N'-methylenebisacrylamide as a crosslinking agent. The beads were packed into solid-phase extraction columns, and temperature-dependent cell elution from the columns was found using HL-60 and Jurkat cells. The retention HL-60 and Jurkat cells in columns containing cationic beads at 37 °C was 95.3% to 99.6% and 95.0% to 98.8%, respectively. By contrast, beads without cationic properties exhibited low cell retention (20.6% for HL-60 and 32.5% for Jurkat cells). The cells were mainly retained through both electrostatic and hydrophobic interactions. The retained HL-60 (4.9%) and Jurkat cells (40%) were eluted at 4 °C from the column with a low composition of cationic monomer (DMAPAAm, 1 mol% in copolymer), because the temperature-responsive hydrogels on the beads became hydrophilic, decreasing the hydrophobic interactions between the cells and the beads. A higher number of Jurkat cells than HL-60 cells were eluted because of differences in their electrostatic properties (Jurkat cells: -2.53 mV; HL-60 cells: -20.7 mV). The results indicated that cell retention by the hydrogel-coated beads packed in a solid phase extraction column could be modulated simply by changing the temperature.
Collapse
|
50
|
Effect of Polymer Phase Transition Behavior on Temperature-Responsive Polymer-Modified Liposomes for siRNA Transfection. Int J Mol Sci 2019; 20:E430. [PMID: 30669495 PMCID: PMC6358841 DOI: 10.3390/ijms20020430] [Citation(s) in RCA: 34] [Impact Index Per Article: 6.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 01/10/2019] [Revised: 01/15/2019] [Accepted: 01/15/2019] [Indexed: 12/11/2022] Open
Abstract
Small interfering RNAs (siRNAs) have been attracting significant attention owing to their gene silencing properties, which can be utilized to treat intractable diseases. In this study, two temperature-responsive liposomal siRNA carriers were prepared by modifying liposomes with different polymers-poly(N-isopropylacrylamide-co-N,N-dimethylaminopropyl acrylamide) (P(NIPAAm-co-DMAPAAm)) and poly(N-isopropylacrylamide-co-N,N-dimethylacrylamide) P(NIPAAm-co-DMAAm). The phase transition of P(NIPAAm-co-DMAPAAm) was sharper than that of P(NIPAAm-co-DMAAm), which is attributed to the lower co-monomer content. The temperature dependent fixed aqueous layer thickness (FALT) of the prepared liposomes indicated that modifying liposomes with P(NIPAAm-co-DMAPAAm) led to a significant change in the thickness of the fixed aqueous monolayer between 37 °C and 42 °C; while P(NIPAAm-co-DMAAm) modification led to FALT changes over a broader temperature range. The temperature-responsive liposomes exhibited cellular uptake at 42 °C, but were not taken up by cells at 37 °C. This is likely because the thermoresponsive hydrophilic/hydrophobic changes at the liposome surface induced temperature-responsive cellular uptake. Additionally, siRNA transfection of cells for the prevention of luciferase and vascular endothelial growth factor (VEGF) expression was modulated by external temperature changes. P(NIPAAm-co-DMAPAAm) modified liposomes in particular exhibited effective siRNA transfection properties with low cytotoxicity compared with P(NIPAAm-co-DMAAm) modified analogues. These results indicated that the prepared temperature-responsive liposomes could be used as effective siRNA carriers whose transfection properties can be modulated by temperature.
Collapse
|