1
|
Foest D, Franzke J, Brandt S. Quasi-Simultaneous Identification of Polar and Neutral Lipids in Mass Spectrometry by kHz Switching of Electrospray and Plasma Ionization. Anal Chem 2025; 97:2011-2018. [PMID: 39829407 DOI: 10.1021/acs.analchem.4c03621] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/22/2025]
Abstract
The identification of polar and neutral lipid species as biomarkers in complex biological samples is a key task in clinical and life sciences. Electrospray and plasma-based ionization techniques are necessary to cover the full range of lipidomes, owing to their limited molecular polarity ranges. However, combining both to generate hybrid spectra is difficult without averaging spectra, as electrospray and plasma sources operate under vastly different conditions. Their electric fields also interfere, resulting in a mutual destabilization of the ionization processes. Herein, a heated nanoelectrospray is combined with a flexible microtube plasma using a rapid (kHz range) switching process (heated nESI-sFμTP) to generate quasi-simultaneous ionization. This approach loads the ion trap with polar and less-polar ions during each injection cycle, generating hybrid spectra without averaging it. The performance of the quasi-simultaneous approach is investigated in positive ion mode, comparing it with conventional ion sources through the analysis of complex lipid liver and heart samples. While no improvements are observed in negative ion mode, the novel quasi-simultaneous approach shows great potential for analyzing complex samples in positive ion mode. The combined heated nESI-sFμTP exceeds the molecular polarity range of individual sources, offering excellent ionization efficiency and MS2 capabilities.
Collapse
Affiliation(s)
- Daniel Foest
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e.V., Bunsen-Kirchhoff-Straße 11, D-44139 Dortmund, Germany
| | - Joachim Franzke
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e.V., Bunsen-Kirchhoff-Straße 11, D-44139 Dortmund, Germany
| | - Sebastian Brandt
- Leibniz-Institut für Analytische Wissenschaften-ISAS-e.V., Bunsen-Kirchhoff-Straße 11, D-44139 Dortmund, Germany
| |
Collapse
|
2
|
Dryahina K, Polášek M, Jašík J, Sovová K, Španěl P. Ion Chemistry in Dielectric Barrier Discharge Ionization: Recent Advances in Direct Gas Phase Analyses. MASS SPECTROMETRY REVIEWS 2024. [PMID: 39506464 DOI: 10.1002/mas.21914] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/31/2024] [Revised: 10/14/2024] [Accepted: 10/16/2024] [Indexed: 11/08/2024]
Abstract
Dielectric barrier discharge ionization (DBDI) sources, employing low-temperature plasma, have emerged as sensitive and efficient ionization tools with various atmospheric pressure ionization processes. In this review, we summarize a historical overview of the development of DBDI, highlighting key principles of gas-phase ion chemistry and the mechanisms underlying the ionization processes within the DBDI source. These processes start with the formation of reagent ions or metastable atoms from the discharge gas, which depends on the nature of the gas (helium, nitrogen, air) and on the presence of water vapor or other compounds or dopants. The processes of ionizing the analyte molecules are summarized, including Penning ionization, electron transfer, proton transfer and ligand switching from secondary hydrated hydronium ions. Presently, the DBDI-MS methods face a challenge in the accurate quantification of gaseous analytes, limiting its broader application in biological, environmental, and medical realms where relative quantification using standards is inherently complex for gaseous matrices. Finally, we propose future avenues of research to enhance the analytical capabilities of DBDI-MS.
Collapse
Affiliation(s)
- Kseniya Dryahina
- J. Heyrovský Institute of Physical Chemistry, Czech Academy of Sciences, Prague, Czechia
| | - Miroslav Polášek
- J. Heyrovský Institute of Physical Chemistry, Czech Academy of Sciences, Prague, Czechia
| | - Juraj Jašík
- J. Heyrovský Institute of Physical Chemistry, Czech Academy of Sciences, Prague, Czechia
| | - Kristýna Sovová
- J. Heyrovský Institute of Physical Chemistry, Czech Academy of Sciences, Prague, Czechia
| | - Patrik Španěl
- J. Heyrovský Institute of Physical Chemistry, Czech Academy of Sciences, Prague, Czechia
| |
Collapse
|
3
|
Zhang YD, Ma C, Zheng KW, Han SQ, Ha W, Shi YP. Direct and Rapid Visualization of the Spatial Distribution of Cholesterol in Alzheimer's and Cancer Tissue via MALDI Mass Spectrometry Imaging. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2024; 35:1756-1767. [PMID: 39001840 DOI: 10.1021/jasms.4c00130] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 07/15/2024]
Abstract
Cholesterol is a vital component of the central nervous system and tissues, and understanding its spatial distribution is crucial for biology, pathophysiology, and diagnostics. However, direct imaging of cholesterol using matrix-assisted laser desorption/ionization mass spectrometry imaging (MALDI-MSI) remains challenging and time-consuming due to the difficulty in ionizing the sterol molecule. To tackle this issue, a MALDI-MSI method is established for direct and rapid analysis of the spatial distribution of cholesterol in Alzheimer's disease (AD), different cancer tissues and organs via MALDI-MSI. This excellent imaging performance depends on the study and systemic optimization of various conditions that affect the imaging of MALDI-MSI. In this case, we report the distribution and levels of cholesterol across specific structures of the AD mouse brain and different tumor tissue and organs. According to the results, the content of cholesterol in the AD mouse cerebellum, especially in the arborvitae, was significantly higher than that in the wild type (WT) model. Furthermore, we successfully visualize the distribution of cholesterol in other organs, such as the heart, liver, spleen, kidney, pancreas, as well as tumor tissues parenchyma and interstitium using MALDI-MSI. Notably, the attribution of cholesterol MS/MS hydrocarbon fragments was systematically investigated. Our presented optimization strategy and established MALDI-MSI method can be easily generalized for different animal tissues or live samples, thereby facilitating the potential for applications of MALDI-MSI in clinical, medical and biological research.
Collapse
Affiliation(s)
- Yi-Da Zhang
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources, Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Lanzhou 730000, P. R. China
| | - Chen Ma
- Gansu Province Key Laboratory of Evidence Science Techniques Research and Application, Gansu University of Political Science and Law, Lanzhou 730070, P. R. China
| | - Kai-Wen Zheng
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources, Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Lanzhou 730000, P. R. China
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Si-Qi Han
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources, Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Lanzhou 730000, P. R. China
- University of Chinese Academy of Sciences, Beijing 100049, P. R. China
| | - Wei Ha
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources, Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Lanzhou 730000, P. R. China
| | - Yan-Ping Shi
- CAS Key Laboratory of Chemistry of Northwestern Plant Resources, Key Laboratory for Natural Medicine of Gansu Province, Lanzhou Institute of Chemical Physics, Chinese Academy of Sciences (CAS), Lanzhou 730000, P. R. China
| |
Collapse
|
4
|
Bouza M, Ahlmann N, García-Reyes JF, Franzke J. Solvent-Assisted Laser Desorption Flexible Microtube Plasma Mass Spectrometry for Direct Analysis of Dried Samples on Paper. Anal Chem 2023; 95:18370-18378. [PMID: 37902451 PMCID: PMC10733904 DOI: 10.1021/acs.analchem.3c03009] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2023] [Revised: 09/11/2023] [Accepted: 10/20/2023] [Indexed: 10/31/2023]
Abstract
The present study investigated the potential for solvent-assisted laser desorption coupled with flexible microtube plasma ionization mass spectrometry (SALD-FμTP-MS) as a rapid analytical technique for direct analysis of surface-deposited samples. Paper was used as the demonstrative substrate, and an infrared hand-held laser was employed for sample desorption, aiming to explore cost-effective sampling and analysis methods. SALD-FμTP-MS offers several advantages, particularly for biofluid analysis, including affordability, the ability to analyze low sample volumes (<10 μL), expanded chemical coverage, sample and substrate stability, and in situ analysis and high throughput potential. The optimization process involved exploring the use of viscous solvents with high boiling points as liquid matrices. This approach aimed to enhance desorption and ionization efficiencies. Ethylene glycol (EG) was identified as a suitable solvent, which not only improved sensitivity but also ensured substrate stability during analysis. Furthermore, the addition of cosolvents such as acetonitrile/water (1:1) and ethyl acetate further enhanced sensitivity and reproducibility for a standard solution containing amphetamine, imazalil, and cholesterol. Optimized conditions for reproducible and sensitive analysis were determined as 1000 ms of laser exposure time using a 1 μL solvent mixture of 60% EG and 40% acetonitrile (ACN)/water (1:1). A mixture of 60% EG and 40% ACN/water (1:1) resulted in signal enhancements and relative standard deviations of 12, 20, and 13% for the evaluated standards, respectively. The applicability of SALD-FμTP-MS was further evaluated by successfully analyzing food, water, and biological samples, highlighting the potential of SALD-FμTP-MS analysis, particularly for thermolabile and polarity diverse compounds.
Collapse
Affiliation(s)
- Marcos Bouza
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071 Jaén, Spain
| | - Norman Ahlmann
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| | - Juan F. García-Reyes
- Analytical
Chemistry Research Group, Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, 23071 Jaén, Spain
| | - Joachim Franzke
- ISAS—Leibniz
Institut für Analytische Wissenschaften, Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| |
Collapse
|
5
|
Foest D, Knodel A, Ahrends R, Coman C, Franzke J, Brandt S. Flexible Microtube Plasma for the Consecutive-Ionization of Cholesterol in Nano-Electrospray Mass Spectrometry. Anal Chem 2023. [PMID: 37220280 DOI: 10.1021/acs.analchem.2c04052] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/25/2023]
Abstract
Electrospray ionization mass spectrometry (ESI-MS) is an established method for the identification of biomarkers. By nano-ESI (nESI), the polar molecular fraction of complex biological samples can be successfully ionized. In contrast, the less-polar free cholesterol, which serves as an important biomarker for several human diseases, is barely accessible by nESI. Although, complex scan functions of modern high-resolution MS devices are able to increase the signal-to-noise ratio, they are limited by the ionization efficiency of the nESI. One possible method to increase the ionization efficiency is the derivatization with acetyl chloride, however interferences with cholesteryl esters must be considered, so chromatographic separation or complex scan functions may be required. A novel approach to increase the yield of cholesterol ions of the nESI could be the application of a second consecutive-ionization process. This publication presents the flexible microtube plasma (FμTP) as a consecutive-ionization source, which allows the determination of cholesterol in nESI-MS analysis. Focusing on the analytical performance, the nESI-FμTP approach increases the cholesterol signal yield in a complex liver extract by a factor of 49. The repeatability and long-term stability could be successfully evaluated. A linear dynamic range of 1.7 orders of magnitude, a minimum detectability of 5.46 mg/L, and a high accuracy (deviation, -8.1%) demonstrates the nESI-FμTP-MS as an excellent approach for a derivatization-free determination of cholesterol.
Collapse
Affiliation(s)
- Daniel Foest
- Miniaturisation, Leibniz-Institut für Analytische Wissenschaften─ISAS─e.V., Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| | - Alexander Knodel
- Miniaturisation, Leibniz-Institut für Analytische Wissenschaften─ISAS─e.V., Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| | - Robert Ahrends
- Department of Analytical Chemistry, University of Vienna, Währingstr. 38, A-1090 Vienna, Austria
| | - Cristina Coman
- Department of Analytical Chemistry, University of Vienna, Währingstr. 38, A-1090 Vienna, Austria
| | - Joachim Franzke
- Miniaturisation, Leibniz-Institut für Analytische Wissenschaften─ISAS─e.V., Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| | - Sebastian Brandt
- Miniaturisation, Leibniz-Institut für Analytische Wissenschaften─ISAS─e.V., Bunsen-Kirchhoff-Str. 11, 44139 Dortmund, Germany
| |
Collapse
|
6
|
Yue H, He F, Zhao Z, Duan Y. Plasma-based ambient mass spectrometry: Recent progress and applications. MASS SPECTROMETRY REVIEWS 2023; 42:95-130. [PMID: 34128567 DOI: 10.1002/mas.21712] [Citation(s) in RCA: 10] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/10/2021] [Revised: 05/28/2020] [Accepted: 06/02/2020] [Indexed: 06/12/2023]
Abstract
Ambient mass spectrometry (AMS) has grown as a group of advanced analytical techniques that allow for the direct sampling and ionization of the analytes in different statuses from their native environment without or with minimum sample pretreatments. As a significant category of AMS, plasma-based AMS has gained a lot of attention due to its features that allow rapid, real-time, high-throughput, in vivo, and in situ analysis in various fields, including bioanalysis, pharmaceuticals, forensics, food safety, and mass spectrometry imaging. Tens of new methods have been developed since the introduction of the first plasma-based AMS technique direct analysis in real-time. This review first provides a comprehensive overview of the established plasma-based AMS techniques from their ion source configurations, mechanisms, and developments. Then, the progress of the representative applications in various scientific fields in the past 4 years (January 2017 to January 2021) has been summarized. Finally, we discuss the current challenges and propose the future directions of plasma-based AMS from our perspective.
Collapse
Affiliation(s)
- Hanlu Yue
- College of Life Sciences, Sichuan University, Chengdu, China
| | - Feiyao He
- College of Life Sciences, Sichuan University, Chengdu, China
| | - Zhongjun Zhao
- School of Chemical Engineering, Sichuan University, Chengdu, China
| | - Yixiang Duan
- College of Life Sciences, Sichuan University, Chengdu, China
- School of Manufacturing Science and Engineering, Sichuan University, Chengdu, China
| |
Collapse
|
7
|
Ionization of semi-fluorinated n-alkanes in controlled atmosphere using flexible micro-tube plasma (FμTP) ionization source with square- and sine-wave voltage. Talanta 2022; 249:123662. [PMID: 35691129 DOI: 10.1016/j.talanta.2022.123662] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/07/2022] [Revised: 05/10/2022] [Accepted: 06/04/2022] [Indexed: 11/21/2022]
Abstract
Non-thermal plasma-based ionization sources have been widely used and shown excellent soft ionization performance in mass spectrometry. Despite their extensive application, the ionization mechanisms of these sources are of great interest for further exploring their full potential. A controlled atmosphere can provide a clean and controllable ionization environment and is beneficial for studying the ionization mechanism. The plasma source itself also has a significant impact on the ionization mechanism of the analyte, and the voltage waveform is one of the key parameters for controlling the plasma source. In this paper, a miniature flexible micro-tube plasma (FμTP) ionization source was sustained using both square and sine-wave voltage. The ionization processes of typical semi-fluorinated n-alkanes (SFAs) were investigated in the controlled atmosphere filled with 80% N2 and 20% O2. The main mass peaks using both square and sine-wave voltages are found to be [M-mH]+ and [M-mH+nO]+ (m = 1, 3; n = 0, 1, 2). However, for the square-wave voltage, the [M-H+O]+ species are the most abundant while [M-H]+ species are dominant for the sine-wave voltage, showing that the plasma generated with sine-wave voltage is somewhat "softer" than the one with square-wave voltage for SFAs. With the assistance of optical spectroscopy, the plasma developments in one discharge cycle for both voltage waveforms were obtained. Only one discharge can be found in each half cycle for square-wave voltage while several for the sine-wave voltage. These would be responsible for the different ionization behaviors in these two cases. This work provides more insight into the ionization mechanism of SFAs and more understanding of plasma-based soft ionization. In addition, the analytical performance was evaluated to be comparable when using these two voltage generators with a big difference in cost, which will benefit the instrumental development.
Collapse
|
8
|
Foest D, Knodel A, Brandt S, Franzke J. Coupling paper spray ionization with the flexible microtube plasma for the determination of low polar biomarkers in mass spectrometry. Anal Chim Acta 2022; 1201:339619. [DOI: 10.1016/j.aca.2022.339619] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/04/2021] [Revised: 01/21/2022] [Accepted: 02/14/2022] [Indexed: 11/15/2022]
|
9
|
Knodel A, Marggraf U, Hoffmann-Posorske E, Burhenn S, Brandt S, Ahlmann N, Foest D, Lorenz K, Franzke J. Pulsed Blue Laser Diode Thermal Desorption Microplasma Imaging Mass Spectrometry. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2022; 33:45-53. [PMID: 34856796 DOI: 10.1021/jasms.1c00221] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/13/2023]
Abstract
An ambient air laser desorption, plasma ionization imaging method is developed and presented using a microsecond pulsed laser diode for desorption and a flexible microtube plasma for ionization of the neutral desorbate. Inherent parameters such as the laser repetition rate and pulse width are optimized to the imaging application. For the desorption substrate, copper spots on a copper-glass sandwich structure are used. This novel design enables imaging without ablating the metal into the mass spectrometer. On this substrate, fixed calibration markers are used to decrease the positioning error in the imaging process, featuring a 3D offset correction within the experiment. The image is both screened spot-by-spot and per line scanning at a constant speed, which allows direct comparison. In spot-by-spot scanning, a novel algorithm is presented to unfold and to reconstruct the imaging data. This approach significantly decreases the time required for the imaging process, which allows imaging even at decreased sampling rates and thus higher mass resolution. After the experiment, the raw data is automatically converted and interpreted by a second algorithm, which allows direct visualization of the image from the data, even on low-intensity signals. Mouse liver microtome cuts have been screened for dehydrated cholesterol, proving good agreement of the unfolded data with the morphology of the tissue. The method optically resolves 30 μm, with 30 μm diameter copper spots and a 10 μm gap. No conventional chemical matrices or vacuum conditions are required.
Collapse
Affiliation(s)
- Alexander Knodel
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Ulrich Marggraf
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Edeltraut Hoffmann-Posorske
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Sebastian Burhenn
- Experimental Physics II, Faculty of Physics and Astronomy, Ruhr-University Bochum, 44801 Bochum, Germany
| | - Sebastian Brandt
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Norman Ahlmann
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Daniel Foest
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Kristina Lorenz
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
- Institute of Pharmacology and Toxicology, University of Würzburg, 97078 Würzburg, Germany
| | - Joachim Franzke
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| |
Collapse
|
10
|
Lu Q, Xu Z, You X, Ma S, Zenobi R. Atmospheric Pressure Mass Spectrometry Imaging Using Laser Ablation, Followed by Dielectric Barrier Discharge Ionization. Anal Chem 2021; 93:6232-6238. [PMID: 33826303 DOI: 10.1021/acs.analchem.1c00549] [Citation(s) in RCA: 20] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/21/2022]
Abstract
Mass spectrometry imaging (MSI) has become a powerful tool in diverse fields, for example, life science, biomaterials, and catalysis, for its ability of in situ and real-time visualization of the location of chemical compounds in samples. Although laser ablation (LA) achieves high spatial resolution in MSI, the ion yield can be very low. We therefore combined an LA system with an ambient ion source for post-ionization and an atmospheric pressure (AP) inlet mass spectrometer to construct a novel AP-MSI platform. A dielectric barrier discharge ionization (DBDI) source is operated in the "active sampling capillary" configuration, can be coupled to any mass spectrometer with an AP interface, and possesses high ion transmission efficiency. This study presents some application examples based on LA-DBDI, a low-cost and flexible strategy for AP-MSI, which does not require any sample pretreatment, and we show MS imaging of endogenous species in a traditional Chinese herbal medicine and of a drug molecule in zebra fish tissue, with a lateral resolution of ≈20 μm.
Collapse
Affiliation(s)
- Qiao Lu
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Zhouyi Xu
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Xue You
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Siyuan Ma
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Renato Zenobi
- Department of Chemistry and the MOE Key Laboratory of Spectrochemical Analysis & Instrumentation, College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China.,Department of Chemistry and Applied Biosciences, ETH Zurich, CH-8093 Zurich , Switzerland
| |
Collapse
|
11
|
Knodel A, Foest D, Brandt S, Ahlmann N, Marggraf U, Gilbert-López B, Franzke J. Detection and Evaluation of Lipid Classes and Other Hydrophobic Compounds Using a Laser Desorption/Plasma Ionization Interface. Anal Chem 2020; 92:15212-15220. [DOI: 10.1021/acs.analchem.0c03839] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/07/2023]
Affiliation(s)
- Alexander Knodel
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Daniel Foest
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Sebastian Brandt
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Norman Ahlmann
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Ulrich Marggraf
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| | - Bienvenida Gilbert-López
- Analytical Chemistry Research Group (FQM-323), Department of Physical and Analytical Chemistry, University of Jaén, Campus Las Lagunillas, Edif. B-3, 23071 Jaén, Spain
| | - Joachim Franzke
- Leibniz-Institut für Analytische Wissenschaften - ISAS - e.V., Bunsen-Kirchhoff-Straße 11, 44139 Dortmund, Germany
| |
Collapse
|
12
|
Gong X, Zhang D, Embile IB, She Y, Shi S, Gamez G. Low-Temperature Plasma Probe Mass Spectrometry for Analytes Separated on Thin-Layer Chromatography Plates: Direct vs Laser Assisted Desorption. JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY 2020; 31:1981-1993. [PMID: 32810399 DOI: 10.1021/jasms.0c00246] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
Thin-layer chromatography (TLC) is a widespread technique because it allows fast, simple, and inexpensive analyte separations. In addition, direct analysis of the compounds separated on TLC plates via mass spectrometry (MS) has been shown to provide high sensitivity and selectivity while avoiding time-consuming sample extraction protocols. Here, direct desorption low-temperature plasma-mass spectrometry (LTP-MS) as well as diode laser assisted desorption (LD) LTP-MS are studied for direct spatially resolved analysis of compounds from TLC plates. Qualitative and quantitative characterization of amino acids, pharmaceuticals, and structural isomers were performed. The nature of the TLC plate stationary phase was found to have a significant influence, together with the analyte's characteristics, on the desorption efficiency. Tandem MS is shown to greatly improve the limits of detection (LODs). Direct desorption LTP-MS, without external thermal assisted desorption, demonstrates its best performance with cellulose TLC plates (LODs, 0.01 ng/mm2 to 2.55 ng/mm2) and restricted performance with normal-phase (NP) TLC plates (several analytes without observable signal). LD LTP-MS, with systematic optimization of irradiance and focal point diameter, is shown to overcome the direct-desorption limitations and reach significantly improved LODs with NP TLC plates (up to ×1000 better). In addition, a wide-ranging characterization of amino acid analytical figures of merit with LD LTP-MS shows that LODs from 84 pg/mm2 down to 0.3 pg/mm2 are achieved on NP TLC plates.
Collapse
Affiliation(s)
- Xiaoxia Gong
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - Dong Zhang
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - Inah B Embile
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - Yue She
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - Songyue Shi
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| | - Gerardo Gamez
- Department of Chemistry and Biochemistry, Texas Tech University, Lubbock, Texas 79409-1061, United States
| |
Collapse
|