1
|
Che S, Peng X, Shen A, Yin L, She Y, Fu H. A quinoline colorimetric ionic liquid probe by electrostatic enhancement for visual detection of Fe 3+ in food. SPECTROCHIMICA ACTA. PART A, MOLECULAR AND BIOMOLECULAR SPECTROSCOPY 2025; 329:125473. [PMID: 39644817 DOI: 10.1016/j.saa.2024.125473] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/16/2024] [Revised: 11/16/2024] [Accepted: 11/20/2024] [Indexed: 12/09/2024]
Abstract
Excessive or insufficient iron(Ⅲ) will pose burdens of human body, and its content is the key to control the function of iron-fortified food. In this regard, a functionalized quinoline ionic probe, benefiting from the electrostatic attraction, was designed for the colorimetric detection of Fe3+ in food. This probe formed a 2: 1 complex with Fe3+, altering the UV-vis spectra and solution color. The UV-vis detection limit was 0.2 μM, and visually, the color shifted from light-yellow to dark-green as Fe3+ concentrations increased, with a visual detection limit of 3.4 μM, meeting the maximum acceptable level of 5.4 μM. Noteworthy, ionic liquid-based sensing paper was constructed for rapid, semi-quantitative Fe3+ detection. Furthermore, the satisfying recovery (97.4-102.9 %) was obtained in real samples, showcasing the probe's efficiency. This work demonstrated the potential of ionic liquids for the fast, sensitive, and visual detection of Fe3+, offering a promising direction for metal element sensing platforms.
Collapse
Affiliation(s)
- Siying Che
- School of Chemical Engineering&Technology, China University of Mining and Technology, Xuzhou 221116, China; College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310014, China
| | - Xiutan Peng
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310014, China
| | - Anbang Shen
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310014, China
| | - Linlin Yin
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310014, China
| | - Yuanbin She
- College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, 310014, China
| | - Haiyan Fu
- College of Pharmacy, South Central Minzu University, Wuhan 430074, China.
| |
Collapse
|
2
|
Luo JY, Huang ZJ, Zhao M, Li S, Zheng F, Huang X, Liu F, Lin L, Huang ZB, Xie H. One-to-Nine Single Spectroscopic Intelligent Probe for Risk Assessment of Multiple Metals in Drinking Water. Anal Chem 2024; 96:11508-11515. [PMID: 38953489 DOI: 10.1021/acs.analchem.4c02181] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 07/04/2024]
Abstract
26% of the world's population lacks access to clean drinking water; clean water and sanitation are major global challenges highlighted by the UN Sustainable Development Goals, indicating water security in public water systems is at stake today. Water monitoring using precise instruments by skilled operators is one of the most promising solutions. Despite decades of research, the professionalism-convenience trade-off when monitoring ubiquitous metal ions remains the major challenge for public water safety. Thus, to overcome these disadvantages, an easy-to-use and highly sensitive visual method is desirable. Herein, an innovative strategy for one-to-nine metal detection is proposed, in which a novel thiourea spectroscopic probe with high 9-metal affinity is synthesized, acting as "one", and is detected based on the 9 metal-thiourea complexes within portable spectrometers in the public water field; this is accomplished by nonspecialized personnel as is also required. During the processing of multimetal analysis, issues arise due to signal overlap and reproducibility problems, leading to constrained sensitivity. In this innovative endeavor, machine learning (ML) algorithms were employed to extract key features from the composite spectral signature, addressing multipeak overlap, and completing the detection within 30-300 s, thus achieving a detection limit of 0.01 mg/L and meeting established conventional water quality standards. This method provides a convenient approach for public drinking water safety testing.
Collapse
Affiliation(s)
- Jia-Yi Luo
- School of Energy and Environmental Engineering, University of Science and Technology Beijing, Beijing 100083, China
- College of Chemistry, Chemical Engineering & Environmental Science, Minnan Normal University, Zhangzhou 363000, China
| | - Zhao-Jing Huang
- College of Chemistry, Chemical Engineering & Environmental Science, Minnan Normal University, Zhangzhou 363000, China
- College of Chemistry and Chemical Engineering, Xiamen University, Xiamen 361005, China
| | - Ming Zhao
- College of Chemistry, Chemical Engineering & Environmental Science, Minnan Normal University, Zhangzhou 363000, China
| | - Shunxing Li
- College of Chemistry, Chemical Engineering & Environmental Science, Minnan Normal University, Zhangzhou 363000, China
- Fujian Province Key Laboratory of Modern Analytical Science and Separation Technology, Fujian Province University Key Laboratory of Pollution Monitoring and Control, Minnan Normal University, Zhangzhou 3630003, China
| | - Fengying Zheng
- College of Chemistry, Chemical Engineering & Environmental Science, Minnan Normal University, Zhangzhou 363000, China
- Fujian Province Key Laboratory of Modern Analytical Science and Separation Technology, Fujian Province University Key Laboratory of Pollution Monitoring and Control, Minnan Normal University, Zhangzhou 3630003, China
| | - Xuguang Huang
- College of Chemistry, Chemical Engineering & Environmental Science, Minnan Normal University, Zhangzhou 363000, China
- Fujian Province Key Laboratory of Modern Analytical Science and Separation Technology, Fujian Province University Key Laboratory of Pollution Monitoring and Control, Minnan Normal University, Zhangzhou 3630003, China
| | - Fengjiao Liu
- College of Chemistry, Chemical Engineering & Environmental Science, Minnan Normal University, Zhangzhou 363000, China
- Fujian Province Key Laboratory of Modern Analytical Science and Separation Technology, Fujian Province University Key Laboratory of Pollution Monitoring and Control, Minnan Normal University, Zhangzhou 3630003, China
| | - Luxiu Lin
- College of Chemistry, Chemical Engineering & Environmental Science, Minnan Normal University, Zhangzhou 363000, China
- Fujian Province Key Laboratory of Modern Analytical Science and Separation Technology, Fujian Province University Key Laboratory of Pollution Monitoring and Control, Minnan Normal University, Zhangzhou 3630003, China
| | - Zheng Bin Huang
- College of Chemistry, Chemical Engineering & Environmental Science, Minnan Normal University, Zhangzhou 363000, China
| | - Haijiao Xie
- College of Chemistry, Chemical Engineering & Environmental Science, Minnan Normal University, Zhangzhou 363000, China
| |
Collapse
|
3
|
Chen Y, Zhang D, Tang M, Wang Z. Deep Learning-Assisted Colorimetric/Electrical Dual-Sensing System for Ultrafast Detection of Hydrogen Sulfide. ACS Sens 2024; 9:2000-2009. [PMID: 38584366 DOI: 10.1021/acssensors.3c02793] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 04/09/2024]
Abstract
This study presents a colorimetric/electrical dual-sensing system (CEDS) for low-power, high-precision, adaptable, and real-time detection of hydrogen sulfide (H2S) gas. The lead acetate/poly(vinyl alcohol) (Pb(Ac)2/PVA) nanofiber film was transferred onto a polyethylene terephthalate (PET) flexible substrate by electrospinning to obtain colorimetric/electrical sensors. The CEDS was constructed to simultaneously record both the visual and electrical response of the sensor, and the improved Manhattan segmentation algorithm and deep neural network (DNN) were used as its intelligent algorithmic aids to achieve quantitative exposure to H2S. By exploring the mechanism of color change and resistance response of the sensor, a dual-sensitivity mechanism explanation model was proposed to verify that the system, as a dual-mode parallel system, can adequately solve the sensor redundancy problem. The results show that the CEDS can achieve a wide detection range of H2S from 0.1-100 ppm and identify the H2S concentration in 4 s at the fastest. The sensor can be stabilized for 180 days with excellent selectivity and a low limit of detection (LOD) to 0.1 ppm of H2S. In addition, the feasibility of the CEDS for measuring H2S levels in underground waterways was validated. This work provides a new method for adaptable, wide range of applications and low-power, high-precision H2S gas detection.
Collapse
Affiliation(s)
- Yajing Chen
- College of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China
| | - Dongzhi Zhang
- College of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China
| | - Mingcong Tang
- College of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China
| | - Zijian Wang
- College of Control Science and Engineering, China University of Petroleum (East China), Qingdao 266580, China
| |
Collapse
|
4
|
Dei J, Mondal S, Biswas A, Sarkar DJ, Bhattacharyya S, Pal S, Mukherjee S, Sarkar S, Ghosh A, Bansal V, Bandhyopadhyay R, Das BK, Behera BK. Cr-Detector: A simple chemosensing system for onsite Cr (VI) detection in water. PLoS One 2024; 19:e0295687. [PMID: 38170706 PMCID: PMC10763940 DOI: 10.1371/journal.pone.0295687] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/09/2023] [Accepted: 11/27/2023] [Indexed: 01/05/2024] Open
Abstract
Due to the increase in urbanization and industrialization, the load of toxicants in the environment is alarming. The most common toxicants, including heavy metals and metalloids such as hexavalent Chromium, have severe pathophysiological impacts on humans and other aquatic biotas. Therefore, developing a portable rapid detection device for such toxicants in the aquatic environment is necessary. This work portrays the development of a field-portable image analysis device coupled with 3,3',5,5'-tetramethylbenzidine (TMB) as a sensing probe for chromium (VI) detection in the aquatic ecosystem. Sensor parameters, such as reagent concentration, reaction time, etc., were optimized for the sensor development and validation using a commercial UV-Vis spectrophotometer. The chemoreceptor integrated with a uniform illumination imaging system (UIIS) revealed the system's applicability toward Cr(VI) detection. The calibration curve using the R-value of image parameters allows Cr(VI) detection in the linear range of 25 to 600 ppb, which covers the prescribed permissible limit by various regulatory authorities. Furthermore, the adjusted R2 = 0.992 of the linear fit and correlation coefficients of 0.99018 against the spectrophotometric method signifies the suitability of the developed system. This TMB-coupled field-portable sensing system is the first-ever reported image analysis-based technology for detecting a wide range of Cr(VI) in aquatic ecosystems to our knowledge.
Collapse
Affiliation(s)
- Jyotsna Dei
- Aquatic Environmental Biotechnology and Nanotechnology Division, ICAR-Central Inland, Fisheries Research Institute, Kolkata, West Bengal, India
- Department of Instrumentation and Electronics Engineering, Jadavpur University Salt Lake Campus, Kolkata, India
| | - Shirsak Mondal
- Aquatic Environmental Biotechnology and Nanotechnology Division, ICAR-Central Inland, Fisheries Research Institute, Kolkata, West Bengal, India
| | - Ayan Biswas
- Aquatic Environmental Biotechnology and Nanotechnology Division, ICAR-Central Inland, Fisheries Research Institute, Kolkata, West Bengal, India
| | - Dhruba Jyoti Sarkar
- Aquatic Environmental Biotechnology and Nanotechnology Division, ICAR-Central Inland, Fisheries Research Institute, Kolkata, West Bengal, India
| | - Soumyadeb Bhattacharyya
- Agri and Environmental Electronics (AEE) Group, Centre for Development of Advanced Computing (C-DAC), Kolkata, West Bengal, India
| | - Souvik Pal
- Agri and Environmental Electronics (AEE) Group, Centre for Development of Advanced Computing (C-DAC), Kolkata, West Bengal, India
| | - Subhankar Mukherjee
- Agri and Environmental Electronics (AEE) Group, Centre for Development of Advanced Computing (C-DAC), Kolkata, West Bengal, India
| | - Subrata Sarkar
- Agri and Environmental Electronics (AEE) Group, Centre for Development of Advanced Computing (C-DAC), Kolkata, West Bengal, India
| | - Alokesh Ghosh
- Agri and Environmental Electronics (AEE) Group, Centre for Development of Advanced Computing (C-DAC), Kolkata, West Bengal, India
| | - Vipul Bansal
- Ian Potter NanoBioSensing Facility, NanoBiotechnology Research Laboratory, School of Science, RMIT University, Melbourne, Victoria, Australia
| | - Rajib Bandhyopadhyay
- Department of Instrumentation and Electronics Engineering, Jadavpur University Salt Lake Campus, Kolkata, India
| | - Basanta Kumar Das
- Aquatic Environmental Biotechnology and Nanotechnology Division, ICAR-Central Inland, Fisheries Research Institute, Kolkata, West Bengal, India
| | - Bijay Kumar Behera
- Aquatic Environmental Biotechnology and Nanotechnology Division, ICAR-Central Inland, Fisheries Research Institute, Kolkata, West Bengal, India
- College of Fisheries, Rani Lakshmi Bai Central Agricultural University, Jhansi, Uttar Pradesh, India
| |
Collapse
|
5
|
Bao M, Waitkus J, Liu L, Chang Y, Xu Z, Qin P, Chen J, Du K. Micro- and nanosystems for the detection of hemorrhagic fever viruses. LAB ON A CHIP 2023; 23:4173-4200. [PMID: 37675935 DOI: 10.1039/d3lc00482a] [Citation(s) in RCA: 2] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 09/08/2023]
Abstract
Hemorrhagic fever viruses (HFVs) are virulent pathogens that can cause severe and often fatal illnesses in humans. Timely and accurate detection of HFVs is critical for effective disease management and prevention. In recent years, micro- and nano-technologies have emerged as promising approaches for the detection of HFVs. This paper provides an overview of the current state-of-the-art systems for micro- and nano-scale approaches to detect HFVs. It covers various aspects of these technologies, including the principles behind their sensing assays, as well as the different types of diagnostic strategies that have been developed. This paper also explores future possibilities of employing micro- and nano-systems for the development of HFV diagnostic tools that meet the practical demands of clinical settings.
Collapse
Affiliation(s)
- Mengdi Bao
- Department of Chemical and Environmental Engineering, University of California, Riverside, CA, USA.
| | - Jacob Waitkus
- Department of Chemical and Environmental Engineering, University of California, Riverside, CA, USA.
| | - Li Liu
- Department of Chemical and Environmental Engineering, University of California, Riverside, CA, USA.
| | - Yu Chang
- Department of Chemical and Environmental Engineering, University of California, Riverside, CA, USA.
| | - Zhiheng Xu
- Department of Industrial Engineering, Rochester Institute of Technology, Rochester, NY, USA
| | - Peiwu Qin
- Institute of Biopharmaceutical and Health Engineering, Tsinghua Shenzhen International Graduate School, Tsinghua University, Shenzhen, China
| | - Juhong Chen
- Department of Biological Systems Engineering, Virginia Tech, Blacksburg, VA, USA
| | - Ke Du
- Department of Chemical and Environmental Engineering, University of California, Riverside, CA, USA.
| |
Collapse
|