1
|
Lee S, Sun Y, Fan S, Rahim N, Xian Y, Shakhawat MK, Chavarria KA, Vedrin M, Guikema S, Sela L, Kumpel E, Lanzarini-Lopes M, Shen Y, Kirisits MJ, Raskin L, Potgieter S, Dowdell KS, Szczuka A. Moving Beyond the Silos of Opportunistic Pathogen and Disinfection Byproduct Research to Improve Drinking Water System Management. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2025; 59:8900-8921. [PMID: 40313230 PMCID: PMC12080258 DOI: 10.1021/acs.est.4c12586] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 11/20/2024] [Revised: 04/14/2025] [Accepted: 04/15/2025] [Indexed: 05/03/2025]
Abstract
Drinking water opportunistic pathogens (OPs) and disinfection byproducts (DBPs) both pose risks to public health, and their variable occurrence from source to tap complicates efforts to control them simultaneously. Management of OPs and DBPs is further hindered by the historical division between microbial and chemical research. This review brings together the current knowledge regarding OPs and DBPs, identifies factors that influence the occurrence of both, and highlights areas where research is needed to better understand their health risks. First, we examine the current understanding of how OPs and DBPs are jointly influenced by physicochemical parameters, source water characteristics, treatment processes including disinfection, and distribution system properties. Temperature, for example, can affect OP and DBP occurrence, where higher temperatures can promote the growth of some OPs, such as Legionella pneumophila, but temperature's effect on DBPs is species-dependent. Methods for quantifying the risks associated with OPs (quantitative microbial risk assessment) and DBPs (chemical risk assessment) are compared, finding that the numerous assumptions and data gaps associated with each method limit comparability across contaminant types. We highlight the urgent need to fill existing data gaps and develop a more unified risk framework so as to move toward holistic assessment of microbial and chemical risks. This review provides suggestions for future research, highlighting ways that researchers might utilize established practices in OP or DBP studies to further our understanding of the other. For example, analysis of source water organic matter composition, which has advanced our understanding of DBP formation, could be utilized to elucidate how source water characteristics influence OPs. This review bridges the gap between the OP and DBP disciplines, arguing that collaboration between the two is needed to address the pressing challenges facing water systems today.
Collapse
Affiliation(s)
- Soojung Lee
- Department
of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Yue Sun
- Department
of Civil and Environmental Engineering, University of Massachusetts, Amherst, Massachusetts 01002, United States
| | - Shi Fan
- Department
of Civil and Environmental Engineering, The George Washington University, Washington, D.C. 20052, United States
| | - Nowrina Rahim
- Department
of Civil, Architectural, and Environmental Engineering, University of Texas at Austin, Austin, Texas 78712, United States
| | - Yuhao Xian
- Department
of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Mohammad Kiron Shakhawat
- Department
of Civil and Environmental Engineering, University of Massachusetts, Amherst, Massachusetts 01002, United States
| | - Karina A. Chavarria
- Department
of Civil and Environmental Engineering, University of Massachusetts, Amherst, Massachusetts 01002, United States
| | - Matthew Vedrin
- Department
of Civil, Architectural, and Environmental Engineering, University of Texas at Austin, Austin, Texas 78712, United States
| | - Seth Guikema
- Department
of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
- Department
of Industrial and Operations Engineering, Civil and Environmental
Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Lina Sela
- Department
of Civil, Architectural, and Environmental Engineering, University of Texas at Austin, Austin, Texas 78712, United States
| | - Emily Kumpel
- Department
of Civil and Environmental Engineering, University of Massachusetts, Amherst, Massachusetts 01002, United States
| | - Mariana Lanzarini-Lopes
- Department
of Civil and Environmental Engineering, University of Massachusetts, Amherst, Massachusetts 01002, United States
| | - Yun Shen
- Department
of Civil and Environmental Engineering, The George Washington University, Washington, D.C. 20052, United States
| | - Mary Jo Kirisits
- Department
of Civil, Architectural, and Environmental Engineering, University of Texas at Austin, Austin, Texas 78712, United States
| | - Lutgarde Raskin
- Department
of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Sarah Potgieter
- Department
of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| | - Katherine S. Dowdell
- Department
of Civil, Architectural, and Environmental Engineering, University of Texas at Austin, Austin, Texas 78712, United States
- Department
of Civil and Environmental Engineering, University of Utah, Salt Lake
City, Utah 84112, United States
| | - Aleksandra Szczuka
- Department
of Civil and Environmental Engineering, University of Michigan, Ann Arbor, Michigan 48109, United States
| |
Collapse
|
2
|
Hayward C, Ross KE, Brown MH, Bentham R, Nisar MA, Hinds J, Xi J, Whiley H. Microbial risks in drinking water systems: persistence and public health implications of opportunistic premise plumbing pathogens. Front Microbiol 2025; 16:1575789. [PMID: 40406344 PMCID: PMC12095195 DOI: 10.3389/fmicb.2025.1575789] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/12/2025] [Accepted: 04/07/2025] [Indexed: 05/26/2025] Open
Abstract
Introduction The persistence of opportunistic premise plumbing pathogens (OPPPs) in drinking water plumbing systems poses a significant public health risk that is receiving increasing attention yet remains poorly understood. This study investigated the co-occurrence of OPPPs and the influence of building infrastructure properties on their prevalence. Methods Drinking water and biofilm samples were collected from hospitals and private residences across Australia to investigate the abiotic and biotic factors contributing to the growth and proliferation of OPPPs. Results Quantitative polymerase chain reaction assays revealed that 41% of samples tested positive for Pseudomonas aeruginosa, 26% for Staphylococcus aureus, 26% for Legionella spp., 24% for Legionella pneumophila, and 14% for Acinetobacter baumannii. Furthermore, free-living amoebae, including Vermamoeba vermiformis (46%) and Acanthamoeba spp. (25%), were frequently detected, with Acanthamoeba spp. demonstrating a significant positive correlation with all bacterial OPPPs. Overall, results indicated a statistically higher prevalence of OPPPs in residential properties and in biofilms. However, building characteristics, including stagnation, hot water system type, and building age, had inconsistent influences on individual OPPP prevalence. Discussion These results emphasize the need to incorporate risk assessments regarding the complex factors within the premise plumbing environment that contribute to pathogen persistence, to inform evidence based targeted preventative strategies for at-risk populations. These findings are particularly critical for individuals receiving healthcare at home, as inconsistent water treatment and monitoring in residential settings may increase their risk of exposure to OPPPs.
Collapse
Affiliation(s)
- Claire Hayward
- Future Industries Institute, University of South Australia, Mawson Lakes, SA, Australia
- Environmental Health, College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | - Kirstin E. Ross
- Environmental Health, College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | - Melissa H. Brown
- College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
- ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia
| | | | - Muhammad Atif Nisar
- Environmental Health, College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
| | - Jason Hinds
- ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia
- Enware Australia Pty Ltd., Caringbah, NSW, Australia
| | - James Xi
- Enware Australia Pty Ltd., Caringbah, NSW, Australia
| | - Harriet Whiley
- Environmental Health, College of Science and Engineering, Flinders University, Bedford Park, SA, Australia
- ARC Training Centre for Biofilm Research and Innovation, Flinders University, Bedford Park, SA, Australia
| |
Collapse
|
3
|
King JC, Lancaster E, Myers A, Lee J, Dannemiller KC. Case report: contamination of a drinking water distribution system by Exophiala-dominated biofilm in the Midwestern United States. JOURNAL OF WATER AND HEALTH 2025; 23:314-321. [PMID: 40156210 DOI: 10.2166/wh.2025.173] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/09/2024] [Accepted: 01/26/2025] [Indexed: 04/01/2025]
Abstract
Fungal contamination of drinking water distribution systems can impact water quality with implications for public health. We document an instance of Exophiala spp. biofilm contamination of customer taps in the Midwest United States following consumer complaints. Three samples of black biofilm were collected from customer taps in Ohio and then processed using next-generation DNA sequencing of the bacterial 16S and fungal ITS regions. Two samples with successful ITS sequencing were dominated by Exophiala spp., putatively identified as E. cancerae and E. lecanii-corni. Dominant bacterial phyla in samples included Proteobacteria, Bacteroidetes, Actinobacteria, and Acidobacteria. Bacterial composition varied substantially at the family and genus levels, and potentially pathogenic bacteria (i.e., Acinetobacter spp., Legionella spp., Mycobacterium spp., and Pseudomonas spp.) were detected. The potential for fungal contamination of drinking water distribution systems should be evaluated when biofilms are observed.
Collapse
Affiliation(s)
- Jon C King
- Environmental Sciences Graduate Program, The Ohio State University, 3138A Smith Lab, 174 W 18th Ave, Columbus, OH 43210, USA; Department of Civil, Environmental, and Geodetic Engineering, College of Engineering, The Ohio State University, 470 Hitchcock Hall, 2070 Neil Ave, Columbus, OH 43210, USA; Division of Environmental Health Sciences, College of Public Health, The Ohio State University, 1841 Neil Ave, Columbus, OH 43210, USA E-mail:
| | - Emma Lancaster
- Environmental Sciences Graduate Program, The Ohio State University, 3138A Smith Lab, 174 W 18th Ave, Columbus, OH 43210, USA; Division of Environmental Health Sciences, College of Public Health, The Ohio State University, 1841 Neil Ave, Columbus, OH 43210, USA
| | | | - Jiyoung Lee
- Division of Environmental Health Sciences, College of Public Health, The Ohio State University, 1841 Neil Ave, Columbus, OH 43210, USA; Department of Food Science & Technology, The Ohio State University, 2015 Fyffe Rd, Columbus, OH 43210, USA; Infectious Diseases Institute, The Ohio State University, 08D Bricker Hall, 190 North Oval Mall, Columbus, OH 43210, USA
| | - Karen C Dannemiller
- Department of Civil, Environmental, and Geodetic Engineering, College of Engineering, The Ohio State University, 470 Hitchcock Hall, 2070 Neil Ave, Columbus, OH 43210, USA; Division of Environmental Health Sciences, College of Public Health, The Ohio State University, 1841 Neil Ave, Columbus, OH 43210, USA; Sustainability Institute, The Ohio State University, 3018 Smith Lab, 174 W 18th Ave, Columbus, OH 43210, USA
| |
Collapse
|
4
|
Burlingame GA, Bartrand TA. Laying the groundwork for a Legionella pneumophila risk management program for public drinking water systems. JOURNAL OF WATER AND HEALTH 2024; 22:2385-2397. [PMID: 39733363 DOI: 10.2166/wh.2024.476] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/15/2024] [Accepted: 11/10/2024] [Indexed: 12/31/2024]
Abstract
Legionella pneumophila is different from traditional drinking water contaminants because it presents a latent public health risk for public and private drinking water systems and for the building water systems they supply. This paper reviews information on the likelihood of occurrence of L. pneumophila in public water systems to lay a foundation for public water systems, as a stakeholder in public health risk management, to better manage L. pneumophila. Important to this approach is a literature review to identify conditions that could potentially promote L. pneumophila being present in drinking water systems at either an elevated abundance or at an increased frequency of occurrence, and/or water quality and supply conditions that would contribute to its amplification. The literature review allows the development of an inventory of hazardous conditions that a public water system could experience and, therefore, can be used by water systems to develop control and monitoring strategies. However, effective L. pneumophila risk management programs are hampered by significant data and knowledge gaps. Priority research to advance public water system's risk assessments and management of L. pneumophila is proposed.
Collapse
Affiliation(s)
- Gary A Burlingame
- Environmental Science, Policy and Research Institute, 3427 Decatur Street, Philadelphia, PA 19136, USA E-mail:
| | - Timothy A Bartrand
- Environmental Science, Policy and Research Institute, 144 Narberth Ave, Box 407, Narberth, PA 19072, USA
| |
Collapse
|
5
|
Nakanishi T, Hirose M, Asada Y, Itoh S. Legionella community dynamics in a drinking water distribution system: Impact of residual chlorine depletion. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 956:177302. [PMID: 39488281 DOI: 10.1016/j.scitotenv.2024.177302] [Citation(s) in RCA: 1] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Subscribe] [Scholar Register] [Received: 08/06/2024] [Revised: 10/08/2024] [Accepted: 10/28/2024] [Indexed: 11/04/2024]
Abstract
This study investigated the occurrence of Legionella spp. in a chlorinated drinking water distribution system (DWDS), focusing on their community compositions and association with physicochemical water quality. Water samples were collected throughout the DWDS, covering from the treated water reservoir to distal ends. Although Legionella spp. genes were not detected at the reservoir, their abundance dramatically increased along the distribution network, reaching up to 4.4 log copies/L at distal sites. The Legionella communities were further characterized by high-throughput amplicon sequencing targeting the genus-specific 16S rRNA gene. The results revealed a diverse Legionella community, including amplicon sequence variants with high similarity (> 99 %) to potentially pathogenic species such as L. drozanskii and L. pneumophila, albeit at low levels. Moreover, Legionella community diversity increased significantly along the distribution system, leading to distinct community compositions at distal sites. Importantly, decay of residual chlorine concentration was identified as a key factor both in increasing the Legionella gene levels and shaping the community structure. Overall, this study underscores the importance of preventing pipe corrosion and maintaining adequate disinfectant residuals to minimize Legionella regrowth in DWDS.
Collapse
Affiliation(s)
- Tomohiro Nakanishi
- Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto University Katsura, Nishikyo, Kyoto 615-8540, Japan.
| | - Madoka Hirose
- Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto University Katsura, Nishikyo, Kyoto 615-8540, Japan
| | - Yasuhiro Asada
- Research Center for Environmental Quality Management, Graduate School of Engineering, Kyoto University, Yumihama 1-2, Otsu, Shiga 520-0811, Japan; Department of Environmental Health, National Institute of Public Health, 2-3-6 Minami, Wako, Saitama 351-0197, Japan
| | - Sadahiko Itoh
- Department of Environmental Engineering, Graduate School of Engineering, Kyoto University, Kyoto University Katsura, Nishikyo, Kyoto 615-8540, Japan
| |
Collapse
|
6
|
Margot C, Rhoads W, Gabrielli M, Olive M, Hammes F. Dynamics of drinking water biofilm formation associated with Legionella spp. colonization. NPJ Biofilms Microbiomes 2024; 10:101. [PMID: 39368992 PMCID: PMC11455961 DOI: 10.1038/s41522-024-00573-x] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/16/2024] [Accepted: 09/17/2024] [Indexed: 10/07/2024] Open
Abstract
Understanding how Legionella spp. proliferate in multispecies biofilms is essential to develop strategies to control their presence in building plumbing. Here, we analyzed biofilm formation and Legionella spp. colonization on new plumbing material during 8 weeks. Biofilm formation was characterized by an initial increase in intact cell concentrations up to 9.5 × 105 cells/cm2, followed by a steady decrease. We identified Comamonas, Caulobacter, Schlegella, Blastomonas and Methyloversatilis as pioneer genera in the biofilm formation process. Importantly, L. pneumophila was the dominant Legionella spp. and rapidly colonized the biofilms, with culturable cell concentrations peaking at 3.1 × 104 MPN/cm2 after 4 weeks already. Moreover, several Legionella species co-occurred and had distinct dynamics of biofilm colonization. Vermamoeba vermiformis (V. vermiformis) was the dominant protist identified with 18S rRNA gene amplicon sequencing. Together our results highlight that biofilm formation upon introduction of new building plumbing material is a dynamic process where pathogenic Legionella species can be part of the earliest colonizers.
Collapse
Affiliation(s)
- Céline Margot
- Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
- Department of Environmental Systems Science, Institute of Biogeochemistry and Pollutant Dynamics, ETH Zürich, Zürich, Switzerland
| | - William Rhoads
- Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| | - Marco Gabrielli
- Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| | - Margot Olive
- Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland
| | - Frederik Hammes
- Department of Environmental Microbiology, Eawag, Swiss Federal Institute of Aquatic Science and Technology, Dübendorf, Switzerland.
| |
Collapse
|
7
|
Wang H, Hu C, Li Y, Shen Y, Guo J, Shi B, Alvarez PJJ, Yu P. Nano-sized polystyrene and magnetite collectively promote biofilm stability and resistance due to enhanced oxidative stress response. JOURNAL OF HAZARDOUS MATERIALS 2024; 476:134974. [PMID: 38905973 DOI: 10.1016/j.jhazmat.2024.134974] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/06/2024] [Revised: 05/25/2024] [Accepted: 06/18/2024] [Indexed: 06/23/2024]
Abstract
Despite the growing prevalence of nanoplastics in drinking water distribution systems, the collective influence of nanoplastics and background nanoparticles on biofilm formation and microbial risks remains largely unexplored. Here, we demonstrate that nano-sized polystyrene modified with carboxyl groups (nPS) and background magnetite (nFe3O4) nanoparticles at environmentally relevant concentrations can collectively stimulate biofilm formation and prompt antibiotic resistance. Combined exposure of nPS and nFe3O4 by P. aeruginosa biofilm cells stimulated intracellular reactive oxidative species (ROS) production more significantly compared with individual exposure. The resultant upregulation of quorum sensing (QS) and c-di-GMP signaling pathways enhanced the biosynthesis of polysaccharides by 50 %- 66 % and increased biofilm biomass by 36 %- 40 % relative to unexposed control. Consistently, biofilm mechanical stability (measured as Young's modulus) increased by 7.2-9.1 folds, and chemical stress resistance (measured with chlorine disinfection) increased by 1.4-2.0 folds. For P. aeruginosa, the minimal inhibitory concentration of different antibiotics also increased by 1.1-2.5 folds after combined exposure. Moreover, at a microbial community-wide level, metagenomic analysis revealed that the combined exposure enhanced the multi-species biofilm's resistance to chlorine, enriched the opportunistic pathogenic bacteria, and promoted their virulence and antibiotic resistance. Overall, the enhanced formation of biofilms (that may harbor opportunistic pathogens) by nanoplastics and background nanoparticles is an overlooked phenomenon, which may jeopardize the microbial safety of drinking water distribution systems.
Collapse
Affiliation(s)
- Haibo Wang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Chisheng Hu
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Yukang Li
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China
| | - Yun Shen
- Department of Civil and Environmental Engineering, The George Washington University, Washington, DC 20052, USA
| | - Jianhua Guo
- Australian Centre for Water and Environmental Biotechnology, The University of Queensland, St Lucia, Queensland 4072, Australia
| | - Baoyou Shi
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing 100049, China
| | - Pedro J J Alvarez
- Department of Civil and Environmental Engineering, Rice University, Houston, TX 77005, USA
| | - Pingfeng Yu
- College of Environmental and Resource Sciences, Zhejiang University, Hangzhou 310058, China.
| |
Collapse
|
8
|
Kim T, Zhao X, Hozalski RM, LaPara TM. Residual disinfectant effectively suppresses Legionella species in drinking water distribution systems supplied by surface water in Minnesota, USA. THE SCIENCE OF THE TOTAL ENVIRONMENT 2024; 940:173317. [PMID: 38788954 DOI: 10.1016/j.scitotenv.2024.173317] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 10/19/2023] [Revised: 05/10/2024] [Accepted: 05/15/2024] [Indexed: 05/26/2024]
Abstract
Seven public water systems in Minnesota, USA were analyzed from one to five times over a two-year period to assess temporal changes in the concentrations of total bacteria, Legionella spp., and Legionella pneumophila from source (i.e., raw water) through the water treatment process to the end water user. Bacterial biomass was collected by filtering large volumes of raw water (12 to 425 L, median: 38 L) or finished and tap water (27 to 1205 L, median: 448 L) using ultrafiltration membrane modules. Quantitative PCR (qPCR) was then used to enumerate all bacteria (16S rRNA gene fragments), all Legionella spp. (ssrA), and Legionella pneumophila (mip). Total coliforms, Escherichia coli, and L. pneumophila also were quantified in the water samples via cultivation. Median concentrations of total bacteria and Legionella spp. (ssrA) in raw water (8.5 and 4.3 log copies/L, respectively) decreased by about 2 log units during water treatment. The concentration of Legionella spp. (ssrA) in water collected from distribution systems inversely correlated with the total chlorine concentration for chloraminated systems significantly (p = 0.03). Although only 8 samples were collected from drinking water distribution systems using free chlorine as a residual disinfectant, these samples had significantly lower concentrations of Legionella spp. (ssrA) than samples collected from the chloraminated systems (p = 5 × 10-4). There was considerable incongruity between the results obtained via cultivation-independent (qPCR) and cultivation-dependent assays. Numerous samples were positive for L. pneumophila via cultivation, none of which tested positive for L. pneumophilia (mip) via qPCR. Conversely, a single sample tested positive for L. pneumophilia (mip) via qPCR, but this sample tested negative for L. pneumophilia via cultivation. Overall, the results suggest that conventional treatment is effective at reducing, but not eliminating, Legionella spp. from surface water supplies and that residual disinfection is effective at suppressing these organisms within drinking water distribution systems.
Collapse
Affiliation(s)
- Taegyu Kim
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota Twin-Cities, 500 Pillsbury Drive S.E., Minneapolis, MN, USA
| | - Xiaotian Zhao
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota Twin-Cities, 500 Pillsbury Drive S.E., Minneapolis, MN, USA
| | - Raymond M Hozalski
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota Twin-Cities, 500 Pillsbury Drive S.E., Minneapolis, MN, USA; Biotechnology Institute, University of Minnesota Twin Cities, 1479 Gortner Ave, St. Paul, MN, USA
| | - Timothy M LaPara
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota Twin-Cities, 500 Pillsbury Drive S.E., Minneapolis, MN, USA; Biotechnology Institute, University of Minnesota Twin Cities, 1479 Gortner Ave, St. Paul, MN, USA.
| |
Collapse
|
9
|
Furst KE, Graham KE, Weisman RJ, Adusei KB. It's getting hot in here: Effects of heat on temperature, disinfection, and opportunistic pathogens in drinking water distribution systems. WATER RESEARCH 2024; 260:121913. [PMID: 38901309 DOI: 10.1016/j.watres.2024.121913] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 03/05/2024] [Revised: 06/06/2024] [Accepted: 06/07/2024] [Indexed: 06/22/2024]
Abstract
As global temperatures rise with climate change, the negative effects of heat on drinking water distribution systems (DWDS) are of increasing concern. High DWDS temperatures are associated with degradation of water quality through physical, chemical and microbial mechanisms. Perhaps the most pressing concern is proliferation of thermotolerant opportunistic pathogens (OPs) like Legionella pneumophila and Naegleria Fowleri. Many OPs can be controlled in DWDS by residual disinfectants such as chlorine or chloramine, but maintaining protective residuals can be challenging at high temperatures. This critical review evaluates the literature on DWDS temperature, residual disinfectant decay, and OP survival and growth with respect to high temperatures. The findings are synthesized to determine the state of knowledge and future research priorities regarding OP proliferation and control at high DWDS temperatures. Temperatures above 40 °C were reported from multiple DWDS, with a maximum of 52 °C. Substantial diurnal temperature swings from ∼30-50 °C occurred in one DWDS. Many OPs can survive or even replicate at these temperatures. However, most studies focused on just a few OP species, and substantial knowledge gaps remain regarding persistence, infectivity, and shifts in microbial community structure at high temperatures relative to lower water temperatures. Chlorine decay rates substantially increase with temperature in some waters but not in others, for reasons that are not well understood. Decay rates within real DWDS are difficult to accurately characterize, presenting practical limitations for application of temperature-dependent decay models at full scale. Chloramine decay is slower than chlorine except in the presence of nitrifiers, which are especially known to grow in DWDS in warmer seasons and climates, though the high temperature range for nitrification is unknown. Lack of knowledge about DWDS nitrifier communities may hinder development of solutions. Fundamental knowledge gaps remain which prevent understanding even the occurrence of high temperatures in DWDS, much less the overall effect on exposure risk. Potential solutions to minimize DWDS temperatures or mitigate the impacts of heat were identified, many which could be aided by proven models for predicting DWDS temperature. Industry leadership and collaboration is needed to generate practical knowledge for protecting DWDS water quality as temperatures rise.
Collapse
Affiliation(s)
- Kirin E Furst
- Department of Civil, Environmental, & Infrastructure Engineering, George Mason University, 4400 University Drive, Fairfax, VA 22030, United States.
| | - Katherine E Graham
- School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA 30332, United States
| | - Richard J Weisman
- Department of Civil, Environmental, & Infrastructure Engineering, George Mason University, 4400 University Drive, Fairfax, VA 22030, United States
| | - Kadmiel B Adusei
- Department of Civil, Environmental, & Infrastructure Engineering, George Mason University, 4400 University Drive, Fairfax, VA 22030, United States
| |
Collapse
|
10
|
Ren A, Yao M, Fang J, Dai Z, Li X, van der Meer W, Medema G, Rose JB, Liu G. Bacterial communities of planktonic bacteria and mature biofilm in service lines and premise plumbing of a Megacity: Composition, Diversity, and influencing factors. ENVIRONMENT INTERNATIONAL 2024; 185:108538. [PMID: 38422875 DOI: 10.1016/j.envint.2024.108538] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 12/28/2023] [Revised: 02/14/2024] [Accepted: 02/26/2024] [Indexed: 03/02/2024]
Abstract
Although simulated studies have provided valuable knowledge regarding the communities of planktonic bacteria and biofilms, the lack of systematic field studies have hampered the understanding of microbiology in real-world service lines and premise plumbing. In this study, the bacterial communities of water and biofilm were explored, with a special focus on the lifetime development of biofilm communities and their key influencing factors. The 16S rRNA gene sequencing results showed that both the planktonic bacteria and biofilm were dominated by Proteobacteria. Among the 15,084 observed amplicon sequence variants (ASVs), the 33 core ASVs covered 72.8 %, while the 12 shared core ASVs accounted for 62.2 % of the total sequences. Remarkably, it was found that the species richness and diversity of biofilm communities correlated with pipe age. The relative abundance of ASV2 (f_Sphingomonadaceae) was lower for pipe ages 40-50 years (7.9 %) than for pipe ages 10-20 years (59.3 %), while the relative abundance of ASV10 (f_Hyphomonadaceae) was higher for pipe ages 40-50 years (19.5 %) than its presence at pipe ages 20-30 years (1.9 %). The community of the premise plumbing biofilm had significantly higher species richness and diversity than that of the service line, while the steel-plastics composite pipe interior lined with polyethylene (S-PE) harbored significantly more diverse biofilm than the galvanized steel pipes (S-Zn). Interestingly, S-PE was enriched with ASV27 (g_Mycobacterium), while S-Zn pipes were enriched with ASV13 (g_Pseudomonas). Moreover, the network analysis showed that five rare ASVs, not core ASVs, were keystone members in biofilm communities, indicating the importance of rare members in the function and stability of biofilm communities. This manuscript provides novel insights into real-world service lines and premise plumbing microbiology, regarding lifetime dynamics (pipe age 10-50 years), and the influences of pipe types (premise plumbing vs. service line) and pipe materials (S-Zn vs. S-PE).
Collapse
Affiliation(s)
- Anran Ren
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA Delft, The Netherlands; University of Chinese Academy of Sciences, Beijing, China
| | - Mingchen Yao
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA Delft, The Netherlands; University of Chinese Academy of Sciences, Beijing, China
| | - Jiaxing Fang
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Science and Technology, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands
| | - Zihan Dai
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; School of Civil and Environmental Engineering, Georgia Institute of Technology, Atlanta, GA 30332, USA
| | - Xiaoming Li
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; University of Chinese Academy of Sciences, Beijing, China.
| | - Walter van der Meer
- Science and Technology, University of Twente, P.O. Box 217, 7500AE Enschede, The Netherlands; Oasen Drinkwater, PO Box 122, 2800 AC, Gouda, The Netherlands
| | - Gertjan Medema
- Oasen Drinkwater, PO Box 122, 2800 AC, Gouda, The Netherlands; KWR Watercycle Research Institute, P.O. Box 1072, 3430 BB Nieuwegein, The Netherlands; Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI 48823, USA
| | - Joan B Rose
- Department of Fisheries and Wildlife, Michigan State University, East Lansing, MI 48823, USA
| | - Gang Liu
- Key Laboratory of Drinking Water Science and Technology, Research Centre for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing 100085, China; Sanitary Engineering, Department of Water Management, Faculty of Civil Engineering and Geosciences, Delft University of Technology, P.O. Box 5048, 2600 GA Delft, The Netherlands; University of Chinese Academy of Sciences, Beijing, China.
| |
Collapse
|
11
|
Hozalski RM, Zhao X, Kim T, LaPara TM. On-site filtration of large sample volumes improves the detection of opportunistic pathogens in drinking water distribution systems. Appl Environ Microbiol 2024; 90:e0165823. [PMID: 38236032 PMCID: PMC10880612 DOI: 10.1128/aem.01658-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 09/18/2023] [Accepted: 12/06/2023] [Indexed: 01/19/2024] Open
Abstract
In this study, we compared conventional vacuum filtration of small volumes through disc membranes (effective sample volumes for potable water: 0.3-1.0 L) with filtration of high volumes using ultrafiltration (UF) modules (effective sample volumes for potable water: 10.6-84.5 L) for collecting bacterial biomass from raw, finished, and tap water at seven drinking water systems. Total bacteria, Legionella spp., Legionella pneumophila, Mycobacterium spp., and Mycobacterium avium complex in these samples were enumerated using both conventional quantitative PCR (qPCR) and viability qPCR (using propidium monoazide). In addition, PCR-amplified gene fragments were sequenced for microbial community analysis. The frequency of detection (FOD) of Legionella spp. in finished and tap water samples was much greater using UF modules (83% and 77%, respectively) than disc filters (24% and 33%, respectively). The FODs for Mycobacterium spp. in raw, finished, and tap water samples were also consistently greater using UF modules than disc filters. Furthermore, the number of observed operational taxonomic units and diversity index values for finished and tap water samples were often substantially greater when using UF modules as compared to disc filters. Conventional and viability qPCR yielded similar results, suggesting that membrane-compromised cells represented a minor fraction of total bacterial biomass. In conclusion, our research demonstrates that large-volume filtration using UF modules improved the detection of opportunistic pathogens at the low concentrations typically found in public drinking water systems and that the majority of bacteria in these systems appear to be viable in spite of disinfection with free chlorine and/or chloramine.IMPORTANCEOpportunistic pathogens, such as Legionella pneumophila, are a growing public health concern. In this study, we compared sample collection and enumeration methods on raw, finished, and tap water at seven water systems throughout the State of Minnesota, USA. The results showed that on-site filtration of large water volumes (i.e., 500-1,000 L) using ultrafiltration membrane modules improved the frequency of detection of relatively rare organisms, including opportunistic pathogens, compared to the common approach of filtering about 1 L using disc membranes. Furthermore, results from viability quantitative PCR (qPCR) with propidium monoazide were similar to conventional qPCR, suggesting that membrane-compromised cells represent an insignificant fraction of microorganisms. Results from these ultrafiltration membrane modules should lead to a better understanding of the microbial ecology of drinking water distribution systems and their potential to inoculate premise plumbing systems with opportunistic pathogens where conditions are more favorable for their growth.
Collapse
Affiliation(s)
- Raymond M. Hozalski
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, Minneapolis, Minnesota, USA
- Biotechnology Institute, University of Minnesota Twin Cities, St. Paul, Minnesota, USA
| | - Xiaotian Zhao
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, Minneapolis, Minnesota, USA
| | - Taegyu Kim
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, Minneapolis, Minnesota, USA
| | - Timothy M. LaPara
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, Minneapolis, Minnesota, USA
- Biotechnology Institute, University of Minnesota Twin Cities, St. Paul, Minnesota, USA
| |
Collapse
|
12
|
Yin H, Wang H, Wang M, Shi B. The interaction between extracellular polymeric substances and corrosion products in pipes shaped different bacterial communities and the effects of micropollutants. WATER RESEARCH 2023; 247:120822. [PMID: 37950951 DOI: 10.1016/j.watres.2023.120822] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/04/2023] [Revised: 10/30/2023] [Accepted: 11/01/2023] [Indexed: 11/13/2023]
Abstract
There are growing concerns over the effects of micropollutants on biofilms formation and antibiotic resistance gene (ARGs) transmission in drinking water distribution pipes. However, there was no reports about the influence of the interaction between extracellular polymeric substances (EPS) and corrosion products on biofilms formation. Our results indicated that the abundance of quorum sensing (QS)-related genes, polysaccharide and amino acids biosynthesis genes of EPS was 6747-8055 TPM, 2221-2619 TPM, and 1461-1535 TPM in biofilms of cast iron pipes, respectively, which were higher than that of stainless steel pipes. The two-dimensional correlation spectroscopy (2D-COS) analysis of attenuated total reflectance-Fourier transform infrared spectrometry (ATR-FTIR) results indicated that polysaccharide of EPS was more easily adsorbed onto the corrosion products of cast iron pipes. Therefore, more human pathogenic bacteria (HPB) carrying ARGs were formed in biofilms of cast iron pipes. The amide I and amide II components and phosphate moieties of EPS were more susceptible to the corrosion products of stainless steel pipes. Thus, more bacteria genera carrying mobile genetic elements (MGE)-ARG were formed in biofilms of stainless steel pipes due to more abundance of QS-related genes, amino acids biosynthesis genes of EPS and the functional genes related to lipid metabolism. The enrichment of dimethyl phthalate (DMP), perfluorooctanoic acid (PFOA) and sulfadiazine (SUL) in corrosion products induced upregulation of QS and EPS-related genes, which promoted bacteria carrying different ARGs growth in biofilms, inducing more microbial risks.
Collapse
Affiliation(s)
- Hong Yin
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Haibo Wang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China.
| | - Min Wang
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China
| | - Baoyou Shi
- Key Laboratory of Drinking Water Science and Technology, Research Center for Eco-Environmental Sciences, Chinese Academy of Sciences, Beijing, 100085, China; University of Chinese Academy of Sciences, Beijing, 100049, China
| |
Collapse
|
13
|
Greenwich JL, Fleming D, Banin E, Häussler S, Kjellerup BV, Sauer K, Visick KL, Fuqua C. The biofilm community resurfaces: new findings and post-pandemic progress. J Bacteriol 2023; 205:e0016623. [PMID: 37756166 PMCID: PMC10601713 DOI: 10.1128/jb.00166-23] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/29/2023] Open
Abstract
The ninth American Society for Microbiology Conference on Biofilms was convened in-person on 13-17 November 2022 in Charlotte, NC. As the first of these conferences since prior to the start of the COVID-19 pandemic, the energy among the participants of the conference was clear, and the meeting was a tremendous success. The mixture of >330 oral and poster presentations resoundingly embodied the vitality of biofilm research across a wide range of topics and multiple scientific disciplines. Special activities, including a pre-conference symposium for early career researchers, further enhanced the attendee experience. As a general theme, the conference was deliberately structured to provide high levels of participation and engagement among early career scientists.
Collapse
Affiliation(s)
| | - Derek Fleming
- Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, Minnesota, USA
| | - Ehud Banin
- The Mina and Everard Goodman Faculty of Life Sciences, Bar-Ilan University, Ramat-Gan, Israel
| | | | - Birthe V. Kjellerup
- Department of Civil and Environmental Engineering, University of Maryland, College Park, Maryland, USA
| | - Karin Sauer
- Department of Biological Sciences, University of Binghamton, Binghamton, New York, USA
| | - Karen L. Visick
- Department of Microbiology and Immunology, Loyola University Chicago, Maywood, Illinois, USA
| | - Clay Fuqua
- Department of Biology, Indiana University, Bloomington, Indiana, USA
| |
Collapse
|
14
|
Song X, Zhang G, Zhou Y, Li W. Behaviors and mechanisms of microbially-induced corrosion in metal-based water supply pipelines: A review. THE SCIENCE OF THE TOTAL ENVIRONMENT 2023; 895:165034. [PMID: 37355127 DOI: 10.1016/j.scitotenv.2023.165034] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2023] [Revised: 06/14/2023] [Accepted: 06/18/2023] [Indexed: 06/26/2023]
Abstract
Microbially-induced corrosion (MIC) is unstoppable and extensively spread throughout drinking water distribution systems (DWDSs) as the cause of pipe leakage and deteriorating water quality. For maintaining drinking water safety and reducing capital inputs in pipe usage, the possible consequences from MIC in DWDSs is still a research hotspot. Although most studies have investigated the effects of changing environmental factors on MIC corrosion, the occurrence of MIC in DWDSs has not been discussed sufficiently. This review aims to fill this gap by proposing that the formation of deposits with microbial capture may be a source of MIC in newly constructed DWDSs. The microbes early attaching to the rough pipe surface, followed by chemically and microbially-induced mineral deposits which confers resistance to disinfectants is ascribed as the first step of MIC occurrence. MIC is then activated in the newly-built, viable, and accessible microenvironment while producing extracellular polymers. With longer pipe service, oligotrophic microbes slowly grow, and metal pipe materials gradually dissolve synchronously with electron release to microbes, resulting in pipe-wall damage. Different corrosive microorganisms using pipe material as a reaction substrate would directly or indirectly cause different types of corrosion. Correspondingly, the formation of scale layers may reflect the distribution of microbial species and possibly biogenic products. It is therefore assumed that the porous and loose layer is an ideal microbial-survival environment, capable of providing diverse and sufficient ecological niches. The usage and chelation of metabolic activities and metabolites, such as acetic, oxalic, citric and glutaric acids, may lead to the formation of a porous scale layer. Therefore, the microbial interactions within the pipe scale reinforce the stability of microbial communities and accelerate MIC. Finally, a schematic model of the MIC process is presented to interpret MIC from its onset to completion.
Collapse
Affiliation(s)
- Xin Song
- State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China; College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Guosheng Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China; College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Yu Zhou
- State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China; College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China
| | - Weiying Li
- State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai 200092, China; College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China.
| |
Collapse
|
15
|
Kim T, Zhao X, LaPara TM, Hozalski RM. Flushing Temporarily Improves Microbiological Water Quality for Buildings Supplied with Chloraminated Surface Water but Has Little Effect for Groundwater Supplies. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2023; 57:5453-5463. [PMID: 36952669 DOI: 10.1021/acs.est.2c08123] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/18/2023]
Abstract
Microbial communities in premise plumbing systems were investigated after more than 2 months of long-term stagnation, during a subsequent flushing event, and during post-flush stagnation. Water samples were collected from showers in buildings supplied with chlorinated groundwater, untreated groundwater, and chloraminated surface water. The building supplied with chlorinated groundwater generally had the lowest bacterial concentrations across all sites (ranging from below quantification limit to 5.2 log copies/L). For buildings supplied with untreated groundwater, bacterial concentrations (5.0 to 7.6 log copies/L) and microbial community diversity index (ACE) values were consistent throughout sampling. Nontuberculous mycobacteria (NTM) and Legionella pneumophila were not detected in any groundwater-supplied buildings. Total bacteria, Legionella spp., and NTM were abundant in the surface water-supplied buildings following long-term stagnation (up to 7.6, 6.2, and 7.6 log copies/L, respectively). Flushing decreased these concentrations by ∼1 to >4 log units and reduced microbial community diversity, but the communities largely recovered within a week of post-flush stagnation. The results suggest that buildings supplied with disinfected surface water are more likely than buildings supplied with treated or untreated groundwater to experience deleterious changes in microbiological water quality during stagnation and that the water quality improvements from flushing with chloraminated water, while substantial, are short-lived.
Collapse
Affiliation(s)
- Taegyu Kim
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, 500 Pillsbury Drive S.E., Minneapolis, Minnesota 55455, United States
| | - Xiaotian Zhao
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, 500 Pillsbury Drive S.E., Minneapolis, Minnesota 55455, United States
| | - Timothy M LaPara
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, 500 Pillsbury Drive S.E., Minneapolis, Minnesota 55455, United States
- Biotechnology Institute, University of Minnesota Twin Cities, 1479 Gortner Avenue, St. Paul, Minnesota 55108, United States
| | - Raymond M Hozalski
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota Twin Cities, 500 Pillsbury Drive S.E., Minneapolis, Minnesota 55455, United States
- Biotechnology Institute, University of Minnesota Twin Cities, 1479 Gortner Avenue, St. Paul, Minnesota 55108, United States
| |
Collapse
|
16
|
Debnath SK, Debnath M, Srivastava R. Opportunistic etiological agents causing lung infections: emerging need to transform lung-targeted delivery. Heliyon 2022; 8:e12620. [PMID: 36619445 PMCID: PMC9816992 DOI: 10.1016/j.heliyon.2022.e12620] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 02/04/2022] [Revised: 09/03/2022] [Accepted: 12/16/2022] [Indexed: 12/27/2022] Open
Abstract
Lung diseases continue to draw considerable attention from biomedical and public health care agencies. The lung with the largest epithelial surface area is continuously exposed to the external environment during exchanging gas. Therefore, the chances of respiratory disorders and lung infections are overgrowing. This review has covered promising and opportunistic etiologic agents responsible for lung infections. These pathogens infect the lungs either directly or indirectly. However, it is difficult to intervene in lung diseases using available oral or parenteral antimicrobial formulations. Many pieces of research have been done in the last two decades to improve inhalable antimicrobial formulations. However, very few have been approved for human use. This review article discusses the approved inhalable antimicrobial agents (AMAs) and identifies why pulmonary delivery is explored. Additionally, the basic anatomy of the respiratory system linked with barriers to AMA delivery has been discussed here. This review opens several new scopes for researchers to work on pulmonary medicines for specific diseases and bring more respiratory medication to market.
Collapse
|
17
|
Zhu J, Stuetz RM, Hamilton L, Power K, Crosbie ND, Tamburic B. Management of biogenic taste and odour: From source water, through treatment processes and distribution systems, to consumers. JOURNAL OF ENVIRONMENTAL MANAGEMENT 2022; 323:116225. [PMID: 36115245 DOI: 10.1016/j.jenvman.2022.116225] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 07/11/2022] [Revised: 09/05/2022] [Accepted: 09/06/2022] [Indexed: 06/15/2023]
Abstract
Biogenic taste and odour (T&O) have become a global concern for water utilities, due to the increasing frequency of algal blooms and other microbial events arising from the combined effects of climate change and eutrophication. Microbially-produced T&O compounds impact source waters, drinking water treatment plants, and drinking water distribution systems. It is important to manage across the entire biogenic T&O pathway to identify key risk factors and devise strategies that will safeguard the quality of drinking water in a changing world, since the presence of T&O impacts consumer confidence in drinking water safety. This study provides a critical review of current knowledge on T&O-causing microbes and compounds for proactive management, including the identification of abiotic risk factors in source waters, a discussion on the effectiveness of existing T&O barriers in drinking water treatment plants, an analysis of risk factors for biofilm growth in water distribution systems, and an assessment of the impacts of T&O on consumers. The fate of biogenic T&O in drinking water systems is tracked from microbial production pathways, through the release of intracellular T&O by cell lysis, to the treatment of microbial cells and dissolved T&O. Based on current knowledge, five impactful research and management directions across the T&O pathway are recommended.
Collapse
Affiliation(s)
- Jin Zhu
- UNSW Water Research Centre, School of Civil and Environmental Engineering, University of New South Wales, Kensington, NSW, 2052, Australia
| | - Richard M Stuetz
- UNSW Water Research Centre, School of Civil and Environmental Engineering, University of New South Wales, Kensington, NSW, 2052, Australia
| | | | - Kaye Power
- Sydney Water Corporation, Parramatta, NSW, 2150, Australia
| | - Nicholas D Crosbie
- UNSW Water Research Centre, School of Civil and Environmental Engineering, University of New South Wales, Kensington, NSW, 2052, Australia; Melbourne Water Corporation, Docklands, VIC, 3008, Australia
| | - Bojan Tamburic
- UNSW Water Research Centre, School of Civil and Environmental Engineering, University of New South Wales, Kensington, NSW, 2052, Australia.
| |
Collapse
|
18
|
Gu X, Huang D, Chen J, Li X, Zhou Y, Huang M, Liu Y, Yu P. Bacterial Inactivation and Biofilm Disruption through Indigenous Prophage Activation Using Low-Intensity Cold Atmospheric Plasma. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2022; 56:8920-8931. [PMID: 35438974 DOI: 10.1021/acs.est.2c01516] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/14/2023]
Abstract
Biofilms can be pervasive and problematic in water treatment and distribution systems but are difficult to eradicate due to hindered penetration of antimicrobial chemicals. Here, we demonstrate that indigenous prophages activated by low-intensity plasma have the potential for efficient bacterial inactivation and biofilm disruption. Specifically, low-intensity plasma treatment (i.e., 35.20 W) elevated the intracellular oxidative reactive species (ROS) levels by 184%, resulting in the activation of prophage lambda (λ) within antibiotic-resistant Escherichia coli K-12 (lambda+) [E. coli (λ+)]. The phage activation efficiency was 6.50-fold higher than the conventional mitomycin C induction. Following a cascading effect, the activated phages were released upon the lysis of E. coli (λ+), which propagated further and lysed phage-susceptible E. coli K-12 (lambda-) [E. coli (λ-)] within the biofilm. Bacterial intracellular ROS analysis and ROS scavenger tests revealed the importance of plasma-generated ROS (e.g., •OH, 1O2, and •O2-) and associated intracellular oxidative stress on prophage activation. In a mixed-species biofilm on a permeable membrane surface, our "inside-out" strategy could inactivate total bacteria by 49% and increase the membrane flux by 4.33-fold. Furthermore, the metagenomic analysis revealed that the decrease in bacterial abundance was closely associated with the increase in phage levels. As a proof-of-concept, this is the first demonstration of indigenous prophage activations by low-intensity plasma for antibiotic-resistant bacterial inactivation and biofilm eradication, which opens up a new avenue for managing associated microbial problems.
Collapse
Affiliation(s)
- Xia Gu
- College of Environmental Science and Engineering, Donghua University, Songjiang, Shanghai 201620, China
| | - Dan Huang
- College of Environment and Resource Sciences, Zhejiang University, Hangzhou, Zhejiang 310058, China
| | - Juhong Chen
- Department of Biological Systems Engineering, Virginia Tech, Blacksburg, Virginia 24061-0131, United States
| | - Xiang Li
- College of Environmental Science and Engineering, Donghua University, Songjiang, Shanghai 201620, China
| | - Yongquan Zhou
- College of Environmental Science and Engineering, Donghua University, Songjiang, Shanghai 201620, China
| | - Manhong Huang
- College of Environmental Science and Engineering, Donghua University, Songjiang, Shanghai 201620, China
| | - Yanan Liu
- College of Environmental Science and Engineering, Donghua University, Songjiang, Shanghai 201620, China
| | - Pingfeng Yu
- College of Environment and Resource Sciences, Zhejiang University, Hangzhou, Zhejiang 310058, China
| |
Collapse
|
19
|
Farhat N, Kim L, Mineta K, Alarawi M, Gojobori T, Saikaly P, Vrouwenvelder J. Seawater desalination based drinking water: Microbial characterization during distribution with and without residual chlorine. WATER RESEARCH 2022; 210:117975. [PMID: 34952456 DOI: 10.1016/j.watres.2021.117975] [Citation(s) in RCA: 11] [Impact Index Per Article: 3.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/15/2021] [Revised: 12/12/2021] [Accepted: 12/14/2021] [Indexed: 06/14/2023]
Abstract
Monitoring the changes that occur to water during distribution is vital to ensure water safety. In this study, the biological stability of reverse osmosis (RO) produced drinking water, characterized by low cell concentration and low assimilable organic carbon, in combination with chlorine disinfection was investigated. Water quality at several locations throughout the existing distribution network was monitored to investigate whether microbial water quality changes can be identified. Results revealed that the water leaving the plant had an average bacterial cell concentration of 103 cells/mL. A 0.5-1.5 log increase in bacterial cell concentration was observed at locations in the network. The residual disinfectant was largely dissipated in the network from 0.5 mg/L at the treatment plant to less than 0.1 mg/L in the network locations. The simulative study involving miniature distribution networks, mimicking the dynamics of a distribution network, fed with the RO produced chlorinated and non-chlorinated drinking water revealed that distributing RO produced water without residual disinfection, especially at high water temperatures (25-30 °C), poses a higher chance for water quality change. Within six months of operation of the miniature network fed with unchlorinated RO produced water, the adenosine triphosphate (ATP) and total cell concentration (TCC) in the pipe biofilm were 4 × 102 pg ATP/cm2 and 1 × 107 cells/ cm2. The low bacterial cell concentration and organic carbon concentration in the RO-produced water did not prevent biofilm development inside the network with and without residual chlorine. The bacterial community analysis using 16S ribosomal RNA (rRNA) gene sequencing revealed that mesophilic bacteria with higher temperature tolerance and bacteria associated with oligotrophic, nutrient-poor conditions dominated the biofilm, with no indication of the existence of opportunistic pathogenic species. However, chlorination selected against most bacterial groups and the bacterial community that remained was mainly the bacteria capable of surviving disinfection regimes. Biofilms that developed in the presence of chlorine contained species classified as opportunistic pathogens. These biofilms have an impact on shaping the water quality received at the consumer tap. The presence of these bacteria on its own is not a health risk indicator; viability assessment and qPCRs targeting genes specific to the opportunistic pathogens as well as quantitative microbiological risk assessment (QMRA) should be included to assess the risk. The results from this study highlight the importance of implementing multiple barriers to ensure water safety. Changes in water quality detected even when high-quality disinfected RO-produced water is distributed highlight microbiological challenges that chlorinated systems endure, especially at high water temperatures.
Collapse
Affiliation(s)
- Nadia Farhat
- Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia.
| | - Lanhee Kim
- Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Katsuhiko Mineta
- Computational Bioscience Research Center (CBRC), Division of Computer, Electrical and Mathematical Sciences and Engineering (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Mohammed Alarawi
- Computational Bioscience Research Center (CBRC), Division of Computer, Electrical and Mathematical Sciences and Engineering (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Takashi Gojobori
- Computational Bioscience Research Center (CBRC), Division of Computer, Electrical and Mathematical Sciences and Engineering (CEMSE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia; Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Pascal Saikaly
- Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia
| | - Johannes Vrouwenvelder
- Water Desalination and Reuse Center (WDRC), Division of Biological and Environmental Science and Engineering (BESE), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia; Faculty of Applied Sciences, Department of Biotechnology, Delft University of Technology, Van der Maasweg 9, Delft 2629 HZ, Netherlands
| |
Collapse
|
20
|
Gleason JA, Cohn PD. A review of legionnaires' disease and public water systems - Scientific considerations, uncertainties and recommendations. Int J Hyg Environ Health 2021; 240:113906. [PMID: 34923288 DOI: 10.1016/j.ijheh.2021.113906] [Citation(s) in RCA: 5] [Impact Index Per Article: 1.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/08/2021] [Revised: 12/02/2021] [Accepted: 12/13/2021] [Indexed: 11/17/2022]
Abstract
Legionella is an opportunistic premise plumbing pathogen and causative agent of a severe pneumonia called Legionnaires' Disease (LD). Cases of LD have been on the rise in the U.S. and globally. Although Legionella was first identified 45 years ago, it remains an 'emerging pathogen." Legionella is part of the normal ecology of a public water system and is frequently detected in regulatory-compliant drinking water. Drinking water utilities, regulators and public health alike are increasingly required to have a productive understanding of the evolving issues and complex discussions of the contribution of the public water utility to Legionella exposure and LD risk. This review provides a brief overview of scientific considerations important for understanding this complex topic, a review of findings from investigations of public water and LD, including data gaps, and recommendations for professionals interested in investigating public water utilities. Although the current literature is inconclusive in identifying a public water utility as a sole source of an LD outbreak, the evidence is clear that minimizing growth of Legionella in public water utilities through proper maintenance and sustained disinfectant residuals, throughout all sections of the water utility, will lead to a less conducive environment for growth of the bacteria in the system and the buildings they serve.
Collapse
Affiliation(s)
- Jessie A Gleason
- Environmental and Occupational Health Surveillance Program, New Jersey Department of Health, 135 E. State Street, P.O. Box 369, Trenton, NJ, 08625, USA.
| | - Perry D Cohn
- Retired, Environmental and Occupational Health Surveillance Program, New Jersey Department of Health, PO Box 369, Trenton, NJ, 08625, USA.
| |
Collapse
|
21
|
Schwake DO, Alum A, Abbaszadegan M. Legionella Occurrence beyond Cooling Towers and Premise Plumbing. Microorganisms 2021; 9:microorganisms9122543. [PMID: 34946143 PMCID: PMC8706379 DOI: 10.3390/microorganisms9122543] [Citation(s) in RCA: 17] [Impact Index Per Article: 4.3] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/06/2021] [Revised: 11/27/2021] [Accepted: 12/06/2021] [Indexed: 11/18/2022] Open
Abstract
Legionella is an environmental pathogen that is responsible for respiratory disease and is a common causative agent of water-related outbreaks. Due to their ability to survive in a broad range of environments, transmission of legionellosis is possible from a variety of sources. Unfortunately, a disproportionate amount of research that is devoted to studying the occurrence of Legionella in environmental reservoirs is aimed toward cooling towers and premise plumbing. As confirmed transmission of Legionella has been linked to many other sources, an over-emphasis on the most common sources may be detrimental to increasing understanding of the spread of legionellosis. This review aims to address this issue by cataloguing studies which have examined the occurrence of Legionella in less commonly investigated environments. By summarizing and discussing reports of Legionella in fresh water, ground water, saltwater, and distribution system drinking water, future environmental and public health researchers will have a resource to aid in investigating these pathogens in relevant sources.
Collapse
Affiliation(s)
- David Otto Schwake
- Department of Natural Sciences, Middle Georgia State University, 100 University Pkwy, Macon, GA 31206, USA;
| | - Absar Alum
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85287, USA;
| | - Morteza Abbaszadegan
- School of Sustainable Engineering and the Built Environment, Arizona State University, Tempe, AZ 85287, USA;
- Correspondence: ; Tel.: +1-480-965-3868
| |
Collapse
|
22
|
Zhang C, Lu J. Legionella: A Promising Supplementary Indicator of Microbial Drinking Water Quality in Municipal Engineered Water Systems. FRONTIERS IN ENVIRONMENTAL SCIENCE 2021; 9:1-22. [PMID: 35004706 PMCID: PMC8740890 DOI: 10.3389/fenvs.2021.684319] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 05/06/2023]
Abstract
Opportunistic pathogens (OPs) are natural inhabitants and the predominant disease causative biotic agents in municipal engineered water systems (EWSs). In EWSs, OPs occur at high frequencies and concentrations, cause drinking-water-related disease outbreaks, and are a major factor threatening public health. Therefore, the prevalence of OPs in EWSs represents microbial drinking water quality. Closely or routinely monitoring the dynamics of OPs in municipal EWSs is thus critical to ensuring drinking water quality and protecting public health. Monitoring the dynamics of conventional (fecal) indicators (e.g., total coliforms, fecal coliforms, and Escherichia coli) is the customary or even exclusive means of assessing microbial drinking water quality. However, those indicators infer only fecal contamination due to treatment (e.g., disinfection within water utilities) failure and EWS infrastructure issues (e.g., water main breaks and infiltration), whereas OPs are not contaminants in drinking water. In addition, those indicators appear in EWSs at low concentrations (often absent in well-maintained EWSs) and are uncorrelated with OPs. For instance, conventional indicators decay, while OPs regrow with increasing hydraulic residence time. As a result, conventional indicators are poor indicators of OPs (the major aspect of microbial drinking water quality) in EWSs. An additional or supplementary indicator that can well infer the prevalence of OPs in EWSs is highly needed. This systematic review argues that Legionella as a dominant OP-containing genus and natural inhabitant in EWSs is a promising candidate for such a supplementary indicator. Through comprehensively comparing the behavior (i.e., occurrence, growth and regrowth, spatiotemporal variations in concentrations, resistance to disinfectant residuals, and responses to physicochemical water quality parameters) of major OPs (e.g., Legionella especially L. pneumophila, Mycobacterium, and Pseudomonas especially P. aeruginosa), this review proves that Legionella is a promising supplementary indicator for the prevalence of OPs in EWSs while other OPs lack this indication feature. Legionella as a dominant natural inhabitant in EWSs occurs frequently, has a high concentration, and correlates with more microbial and physicochemical water quality parameters than other common OPs. Legionella and OPs in EWSs share multiple key features such as high disinfectant resistance, biofilm formation, proliferation within amoebae, and significant spatiotemporal variations in concentrations. Therefore, the presence and concentration of Legionella well indicate the presence and concentrations of OPs (especially L. pneumophila) and microbial drinking water quality in EWSs. In addition, Legionella concentration indicates the efficacies of disinfectant residuals in EWSs. Furthermore, with the development of modern Legionella quantification methods (especially quantitative polymerase chain reactions), monitoring Legionella in ESWs is becoming easier, more affordable, and less labor-intensive. Those features make Legionella a proper supplementary indicator for microbial drinking water quality (especially the prevalence of OPs) in EWSs. Water authorities may use Legionella and conventional indicators in combination to more comprehensively assess microbial drinking water quality in municipal EWSs. Future work should further explore the indication role of Legionella in EWSs and propose drinking water Legionella concentration limits that indicate serious public health effects and require enhanced treatment (e.g., booster disinfection).
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, OH, United States
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, OH, United States
| |
Collapse
|
23
|
Zhang C, Struewing I, Mistry JH, Wahman DG, Pressman J, Lu J. Legionella and other opportunistic pathogens in full-scale chloraminated municipal drinking water distribution systems. WATER RESEARCH 2021; 205:117571. [PMID: 34628111 PMCID: PMC8629321 DOI: 10.1016/j.watres.2021.117571] [Citation(s) in RCA: 32] [Impact Index Per Article: 8.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/17/2021] [Revised: 08/02/2021] [Accepted: 08/13/2021] [Indexed: 05/06/2023]
Abstract
Water-based opportunistic pathogens (OPs) are a leading cause of drinking-water-related disease outbreaks, especially in developed countries such as the United States (US). Physicochemical water quality parameters, especially disinfectant residuals, control the (re)growth, presence, colonization, and concentrations of OPs in drinking water distribution systems (DWDSs), while the relationship between OPs and those parameters remain unclear. This study aimed to quantify how physicochemical parameters, mainly monochloramine residual concentration, hydraulic residence time (HRT), and seasonality, affected the occurrence and concentrations of four common OPs (Legionella, Mycobacterium, Pseudomonas, and Vermamoeba vermiformis) in four full-scale DWDSs in the US. Legionella as a dominant OP occurred in 93.8% of the 64 sampling events and had a mean density of 4.27 × 105 genome copies per liter. Legionella positively correlated with Mycobacterium, Pseudomonas, and total bacteria. Multiple regression with data from the four DWDSs showed that Legionella had significant correlations with total chlorine residual level, free ammonia concentration, and trihalomethane concentration. Therefore, Legionella is a promising indicator of water-based OPs, reflecting microbial water quality in chloraminated DWDSs. The OP concentrations had strong seasonal variations and peaked in winter and/or spring possibly because of reduced water usage (i.e., increased water stagnation or HRT) during cold seasons. The OP concentrations generally increased with HRT presumably because of disinfectant residual decay, indicating the importance of well-maintaining disinfectant residuals in DWDSs for OP control. The concentrations of Mycobacterium, Pseudomonas, and V. vermiformis were significantly associated with total chlorine residual concentration, free ammonia concentration, and pH and trihalomethane concentration, respectively. Overall, this study demonstrates how the significant spatiotemporal variations of OP concentrations in chloraminated DWDSs correlated with critical physicochemical water quality parameters such as disinfectant residual levels. This work also indicates that Legionella is a promising indicator of OPs and microbial water quality in chloraminated DWDSs.
Collapse
Affiliation(s)
- Chiqian Zhang
- Pegasus Technical Services, Inc., Cincinnati, Ohio, USA
| | - Ian Struewing
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Jatin H Mistry
- United States Environmental Protection Agency, Region 6, Dallas, Texas, USA
| | - David G Wahman
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Jonathan Pressman
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA
| | - Jingrang Lu
- Office of Research and Development, United States Environmental Protection Agency, Cincinnati, Ohio, USA.
| |
Collapse
|
24
|
Zhang X, Xia S, Ye Y, Wang H. Opportunistic pathogens exhibit distinct growth dynamics in rainwater and tap water storage systems. WATER RESEARCH 2021; 204:117581. [PMID: 34461496 DOI: 10.1016/j.watres.2021.117581] [Citation(s) in RCA: 9] [Impact Index Per Article: 2.3] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 05/17/2021] [Revised: 07/09/2021] [Accepted: 08/16/2021] [Indexed: 06/13/2023]
Abstract
Opportunistic pathogens (OPs) are emerging microbial contaminants in engineered water systems, yet their growth potential in rainwater systems has not been evaluated. The purpose of this study was to compare the growth dynamics of bacterial OPs and related genera (Pseudomonas aeruginosa, Legionella spp., L. pneumophila, Mycobacterium spp., and M. avium), two amoebal hosts (Acanthamoeba spp. and Vermamoeba vermiformis), and the fecal indicator Escherichia coli in simulated rainwater and tap water storage systems (SWSSs). Quantitative polymerase chain reaction (q-PCR) analysis of target microorganisms in SWSS influents and effluents demonstrated that P. aeruginosa and Legionella thrived in rainwater, but not in tap water. V. vermiformis proliferated in both rainwater and tap water polyvinyl chloride (PVC) SWSSs, while mycobacteria were largely absent in rainwater SWSSs. Tank materials exerted stronger influence on target microorganisms in rainwater SWSSs relative to tap water SWSSs, with species-specific responses noted in bulk water and biofilm. For instance, P. aeruginosa and V. vermiformis had the highest gene copy numbers in PVC rainwater SWSS effluents and biofilm, while Legionella peaked in stainless steel rainwater SWSS effluents and PVC rainwater SWSS biofilm. These results highlighted the OP contamination risks in rainwater storage systems and provided insights into rainwater system design and operation in terms of OP control.
Collapse
Affiliation(s)
- Xiaodong Zhang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Chengtou Water Group Corporation, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China
| | - Siqing Xia
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China.
| | - Yinyin Ye
- Department of Civil, Structural and Environmental Engineering, University at Buffalo, Buffalo, New York 14260, USA
| | - Hong Wang
- State Key Laboratory of Pollution Control and Resource Reuse, College of Environmental Science and Engineering, Tongji University, Shanghai 200092, China; Shanghai Institute of Pollution Control and Ecological Security, Shanghai 200092, China.
| |
Collapse
|
25
|
Huang FY, Chen QL, Zhang X, Neilson R, Su JQ, Zhou SYD. Dynamics of antibiotic resistance and its association with bacterial community in a drinking water treatment plant and the residential area. ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL 2021; 28:55690-55699. [PMID: 34137009 DOI: 10.1007/s11356-021-14896-1] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 01/26/2021] [Accepted: 06/10/2021] [Indexed: 06/12/2023]
Abstract
Drinking water treatment techniques are used globally in the context of water security and public health, yet they are not applicable to antibiotic resistance gene (ARG) contamination. Using high-throughput quantitative PCR, we analyzed the prevalence and diversity of ARGs and mobile genetic elements (MGEs) in water supplies. A total of 224 ARGs and MGEs were detected in all sampling sites. Absolute abundance and detected number of ARGs decreased significantly (P < 0.05) in sand filter water after drinking water treatment and increased thereafter at point-of-use (household tap water). Changes in the composition and diversity of the bacterial community were observed in water samples at different steps. A significant correlation (P < 0.001) between microbial communities and ARG profiles was observed, and variance in ARG profiles could be primarily attributed to community composition (11.9%), and interaction between community composition, environmental factors and MGEs (30.7%). A network analysis was performed, and the results showed eight bacterial phyla were significantly correlated with nine different classes of ARGs, suggesting the potential bacterial host for ARGs. This study suggested that although the absolute abundance of ARGs decreased after treatment of drinking water treatment plants (DWTPs), the rebounded of ARGs in the water distribution system should not be neglected.
Collapse
Affiliation(s)
- Fu-Yi Huang
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, 1799 Jimei Road, Xiamen, 361021, China
- University of Chinese Academy of Sciences, 19A Yuquan Road, Beijing, 100049, China
| | - Qing-Lin Chen
- Faculty of Veterinary and Agricultural Sciences, The University of Melbourne, Parkville, Victoria, 3010, Australia
| | - Xian Zhang
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, 1799 Jimei Road, Xiamen, 361021, China
| | - Roy Neilson
- Ecological Sciences, The James Hutton Institute, Dundee, Scotland, DD2 5DA, UK
| | - Jian-Qiang Su
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, 1799 Jimei Road, Xiamen, 361021, China
- University of Chinese Academy of Sciences, 19A Yuquan Road, Beijing, 100049, China
| | - Shu-Yi-Dan Zhou
- Key Laboratory of Urban Environment and Health, Institute of Urban Environment, Chinese Academy of Sciences, 1799 Jimei Road, Xiamen, 361021, China.
- University of Chinese Academy of Sciences, 19A Yuquan Road, Beijing, 100049, China.
| |
Collapse
|
26
|
Zuo P, Yu P, Alvarez PJJ. Aminoglycosides Antagonize Bacteriophage Proliferation, Attenuating Phage Suppression of Bacterial Growth, Biofilm Formation, and Antibiotic Resistance. Appl Environ Microbiol 2021; 87:e0046821. [PMID: 34020940 PMCID: PMC8276799 DOI: 10.1128/aem.00468-21] [Citation(s) in RCA: 34] [Impact Index Per Article: 8.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/05/2021] [Accepted: 05/17/2021] [Indexed: 01/21/2023] Open
Abstract
The common cooccurrence of antibiotics and phages in both natural and engineered environments underscores the need to understand their interactions and implications for bacterial control and antibiotic resistance propagation. Here, aminoglycoside antibiotics that inhibit protein synthesis (e.g., kanamycin and neomycin) impeded the replication of coliphage T3 and Bacillus phage BSP, reducing their infection efficiency and mitigating their hindrance of bacterial growth, biofilm formation, and tolerance to antibiotics. For example, treatment with phage T3 reduced subsequent biofilm formation by Escherichia coli liquid cultures to 53% ± 5% of that of the no-phage control, but a smaller reduction of biofilm formation (89% ± 10%) was observed for combined exposure to phage T3 and kanamycin. Despite sharing a similar mode of action with aminoglycosides (i.e., inhibiting protein synthesis) and antagonizing phage replication, albeit to a lesser degree, tetracyclines did not inhibit bacterial control by phages. Phage T3 combined with tetracycline showed higher suppression of biofilm formation than when combined with aminoglycosides (25% ± 6% of the no-phage control). The addition of phage T3 to E. coli suspensions with tetracycline also suppressed the development of tolerance to tetracycline. However, this suppression of antibiotic tolerance development disappeared when tetracycline was replaced with 3 mg/liter kanamycin, corroborating the greater antagonism with aminoglycosides. Overall, this study highlights this overlooked antagonistic effect on phage proliferation, which may attenuate phage suppression of bacterial growth, biofilm formation, antibiotic tolerance, and maintenance of antibiotic resistance genes. IMPORTANCE The coexistence of residual antibiotics and phages is common in many environments, which underscores the need to understand their interactive effects on bacteria and the implications for antibiotic resistance propagation. Here, aminoglycosides acting as bacterial protein synthesis inhibitors impeded the replication of various phages. This alleviated the suppressive effects of phages against bacterial growth and biofilm formation and diminished bacterial fitness costs that suppress the emergence of tolerance to antibiotics. We show that changes in bacteria caused by environmentally relevant concentrations of sublethal antibiotics can affect phage-host dynamics that are commonly overlooked in vitro but can result in unexpected environmental consequences.
Collapse
Affiliation(s)
- Pengxiao Zuo
- Department of Civil and Environmental Engineering, Rice University, Houston, Texas, USA
| | - Pingfeng Yu
- Department of Civil and Environmental Engineering, Rice University, Houston, Texas, USA
| | - Pedro J. J. Alvarez
- Department of Civil and Environmental Engineering, Rice University, Houston, Texas, USA
| |
Collapse
|
27
|
Siedlecka A, Wolf-Baca M, Piekarska K. Microbial communities of biofilms developed in a chlorinated drinking water distribution system: A field study of antibiotic resistance and biodiversity. THE SCIENCE OF THE TOTAL ENVIRONMENT 2021; 774:145113. [PMID: 33610999 DOI: 10.1016/j.scitotenv.2021.145113] [Citation(s) in RCA: 15] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 11/18/2020] [Revised: 12/21/2020] [Accepted: 01/08/2021] [Indexed: 06/12/2023]
Abstract
Antibiotic resistance and biodiversity were investigated in microbial communities attached to inner surfaces of water supply fittings in a chlorinated drinking water distribution system (DWDS) supplied by two independent water treatment plants (WTPs) drawing the same source water. The investigation of the effect of the season, the applied water treatment technology, and type, material, and age of water supply fittings on both antibiotic resistance and biodiversity in biofilms involved collection of tubercles during summer and winter seasons throughout the DWDS. A total of 16 samples were collected (8 per season) from areas supplied by two independent WTPs. Culturable aerobic antibiotic resistant bacteria (ARB) proved more prevalent in summer. Various antibiotic resistance genes (ARGs) were detected, confirming the role of biofilms as ARGs reservoirs, but the abundances of quantified genes (sulI, ermB, qacEΔ1, intI1) were low (a range of <LOQ to 2313 gene copies/mg dry mass of tubercles) throughout the DWDS. In terms of microbial community composition, Proteobacteria were dominant in each sample (51.51-97.13%), and the most abundant genus was Desulfovibrio (0.01-66.69%) belonging to sulphate-reducing bacteria. Biodiversity of microbial communities was shaped by many coexisting factors, including season, water supply fitting material, and sampling site location. Spatial distribution analysis revealed that although only samples collected at the same sampling sites were similar to each other in terms of antibiotic resistance, some samples collected in the close proximity were similar in terms of biodiversity. This suggests that antibiotic resistance spreads only locally over small distances in drinking water biofilms. Although actual drinking water biofilms have been previously investigated in terms of microbial biodiversity, this is the first study that characterised both antibiotic resistance and biodiversity of microbial communities attached to inner surfaces of a real DWDS functioning for decades.
Collapse
Affiliation(s)
- Agata Siedlecka
- Department of Environmental Protection Engineering, Faculty of Environmental Engineering, Wrocław University of Science and Technology, Wyb. Wyspiańskiego 27, 50-370 Wrocław, Poland.
| | - Mirela Wolf-Baca
- Department of Environmental Protection Engineering, Faculty of Environmental Engineering, Wrocław University of Science and Technology, Wyb. Wyspiańskiego 27, 50-370 Wrocław, Poland.
| | - Katarzyna Piekarska
- Department of Environmental Protection Engineering, Faculty of Environmental Engineering, Wrocław University of Science and Technology, Wyb. Wyspiańskiego 27, 50-370 Wrocław, Poland.
| |
Collapse
|
28
|
Pereira A, Silva AR, Melo LF. Legionella and Biofilms-Integrated Surveillance to Bridge Science and Real-Field Demands. Microorganisms 2021; 9:microorganisms9061212. [PMID: 34205095 PMCID: PMC8228026 DOI: 10.3390/microorganisms9061212] [Citation(s) in RCA: 6] [Impact Index Per Article: 1.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/19/2021] [Revised: 05/28/2021] [Accepted: 05/31/2021] [Indexed: 11/16/2022] Open
Abstract
Legionella is responsible for the life-threatening pneumonia commonly known as Legionnaires’ disease or legionellosis. Legionellosis is known to be preventable if proper measures are put into practice. Despite the efforts to improve preventive approaches, Legionella control remains one of the most challenging issues in the water treatment industry. Legionellosis incidence is on the rise and is expected to keep increasing as global challenges become a reality. This puts great emphasis on prevention, which must be grounded in strengthened Legionella management practices. Herein, an overview of field-based studies (the system as a test rig) is provided to unravel the common roots of research and the main contributions to Legionella’s understanding. The perpetuation of a water-focused monitoring approach and the importance of protozoa and biofilms will then be discussed as bottom-line questions for reliable Legionella real-field surveillance. Finally, an integrated monitoring model is proposed to study and control Legionella in water systems by combining discrete and continuous information about water and biofilm. Although the successful implementation of such a model requires a broader discussion across the scientific community and practitioners, this might be a starting point to build more consistent Legionella management strategies that can effectively mitigate legionellosis risks by reinforcing a pro-active Legionella prevention philosophy.
Collapse
|
29
|
Faust KM, Katz LE, Kirisits MJ, Kinney KA, Sela L, Kopytkovskiy M, Russell C, Kaminsky J. Consider How Social Distancing Policies Can Affect Drinking Water Infrastructure Performance. JOURNAL - AMERICAN WATER WORKS ASSOCIATION 2021; 113:74-77. [PMID: 33821012 PMCID: PMC8014058 DOI: 10.1002/awwa.1673] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Indexed: 11/11/2022]
|
30
|
Hozalski RM, LaPara TM, Zhao X, Kim T, Waak MB, Burch T, McCarty M. Flushing of Stagnant Premise Water Systems after the COVID-19 Shutdown Can Reduce Infection Risk by Legionella and Mycobacterium spp. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2020; 54:15914-15924. [PMID: 33232602 DOI: 10.1021/acs.est.0c06357] [Citation(s) in RCA: 36] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/11/2023]
Abstract
There is concern about potential exposure to opportunistic pathogens when reopening buildings closed due to the COVID-19 pandemic. In this study, water samples were collected before, during, and after flushing showers in five unoccupied (i.e., for ∼2 months) university buildings with quantification of opportunists via a cultivation-based assay (Legionella pneumophila only) and quantitative PCR. L. pneumophila were not detected by either method; Legionella spp., nontuberculous mycobacteria (NTM), and Mycobacterium avium complex (MAC), however, were widespread. Using quantitative microbial risk assessment (QMRA), the estimated risks of illness from exposure to L. pneumophila and MAC via showering were generally low (i.e., less than a 10-7 daily risk threshold), with the exception of systemic infection risk from MAC exposure in some buildings. Flushing rapidly restored the total chlorine (as chloramine) residual and decreased bacterial gene targets to building inlet concentrations within 30 min. During the postflush stagnation period, the residual chlorine dissipated within a few days and bacteria rebounded, approaching preflush concentrations after 6-7 days. These results suggest that flushing can quickly improve water quality in unoccupied buildings, but the improvement may only last a few days.
Collapse
Affiliation(s)
- Raymond M Hozalski
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, Minneapolis 55455, Minnesota, United States
| | - Timothy M LaPara
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, Minneapolis 55455, Minnesota, United States
| | - Xiaotian Zhao
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, Minneapolis 55455, Minnesota, United States
| | - Taegyu Kim
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, Minneapolis 55455, Minnesota, United States
| | - Michael B Waak
- Norwegian University of Science and Technology, Trondheim 7031, Norway
- Department of Infrastructure, SINTEF Community, Trondheim 7031, Norway
| | - Tucker Burch
- Agricultural Research Service, U.S. Department of Agriculture, Marshfield, Wisconsin 54449, United States
| | - Michael McCarty
- School of Public Health, University of Minnesota, Minneapolis 55455, Minnesota, United States
| |
Collapse
|
31
|
Rantanen PL, Keinänen-Toivola MM, Ahonen M, González-Martínez A, Mellin I, Vahala R. Decreased natural organic matter in water distribution decreases nitrite formation in non-disinfected conditions, via enhanced nitrite oxidation. WATER RESEARCH X 2020; 9:100069. [PMID: 33083777 PMCID: PMC7552091 DOI: 10.1016/j.wroa.2020.100069] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.2] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 07/09/2020] [Revised: 09/10/2020] [Accepted: 09/12/2020] [Indexed: 06/11/2023]
Abstract
Nitrite in drinking water is a potentially harmful substance for humans, and controlling nitrite formation in drinking water distribution systems (DWDSs) is highly important. The effect of natural organic matter (NOM) on the formation of nitrite in simulated distribution systems was studied. The objective was to inspect how a reduced NOM concentration affected nitrite development via nitrification, separated from the effects of disinfection. We observed that nitrite formation was noticeably sensitive to the changes in the NOM concentrations. Nitrite declined with reduced NOM (TOC 1.0 mg L-1) but increased with the normal NOM concentration of tap water (TOC 1.6 mg L-1). Ammonium oxidation was not altered by the reduced NOM, however, nitrite oxidation was enhanced significantly according to the pseudo-first order reaction rate model interpretation. The enhanced nitrite oxidation was observed with both ammonium and nitrite as the initial nitrogen source. The theoretical maximum nitrite concentrations were higher with the normal concentration of NOM than with reduced NOM. The results suggest that the role of nitrite oxidation may be quite important in nitrite formation in DWDSs and worth further studies. As a practical result, our study supported enhanced NOM removal in non-disinfected DWDSs.
Collapse
Affiliation(s)
- Pirjo-Liisa Rantanen
- Department of Built Environment, Aalto University, PO Box 15200, FI-00076, Aalto, Finland
| | - Minna M. Keinänen-Toivola
- Faculty of Technology, Satakunta University of Applied Sciences, PO Box, 1001, FI-28101, Pori, Finland
| | - Merja Ahonen
- Faculty of Technology, Satakunta University of Applied Sciences, PO Box, 1001, FI-28101, Pori, Finland
| | | | - Ilkka Mellin
- Department of Mathematics and Systems Analysis, Aalto University, PO Box 11100, FI-00076, Aalto, Finland
| | - Riku Vahala
- Department of Built Environment, Aalto University, PO Box 15200, FI-00076, Aalto, Finland
| |
Collapse
|
32
|
Chen J, Li W, Zhang J, Qi W, Li Y, Chen S, Zhou W. Prevalence of antibiotic resistance genes in drinking water and biofilms: The correlation with the microbial community and opportunistic pathogens. CHEMOSPHERE 2020; 259:127483. [PMID: 32634723 DOI: 10.1016/j.chemosphere.2020.127483] [Citation(s) in RCA: 39] [Impact Index Per Article: 7.8] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/13/2020] [Revised: 06/12/2020] [Accepted: 06/20/2020] [Indexed: 06/11/2023]
Abstract
The emergence of antibiotic resistance genes (ARGs) and opportunistic pathogens (OPs) in drinking water system posed potential risks to human health. However, the occurrence of ARGs and OPs in drinking water biofilms is still at its infancy. In this study, we investigated the occurrence of ARGs and OPs in both water and biofilm samples from a drinking water system, and the correlation between ARGs and microbial communities was analyzed. The quantitative PCR results showed that the drinking water treatment process effectively decreased the absolute abundances of ARGs. However, the relative concentration of ARGs did not show a significant difference between raw water and treated water samples. Compared with bulk water and tap water samples, biofilms had higher relative abundances of ARGs. 16 S Illumina Miseq sequencing results showed that microbial communities of biofilms were distinguished with water samples. Meanwhile, qPCR results of OPs also showed that biofilms had higher relative abundances of OPs compared with water samples. Furthermore, the Spearman correlation analysis indicated that Dechloromonas, Desulfovibrio, Methylobacterium and Propionivibrio correlated well with the relative abundance of ARGs. The absolute concentrations of OPs and ARGs also showed a significant correlation. Results of this study suggest that biofilms could serve as the reservoirs for the spread of ARGs and the interaction between biofilms and bulk water requires further research.
Collapse
Affiliation(s)
- Jiping Chen
- College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Weiying Li
- College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China; State Key Laboratory of Pollution Control and Resource Reuse, Tongji University, Shanghai, 200092, China.
| | - Junpeng Zhang
- College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Wanqi Qi
- College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Yue Li
- College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Sheng Chen
- College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| | - Wei Zhou
- College of Environmental Science and Engineering, Tongji University, Shanghai, 200092, China
| |
Collapse
|
33
|
Kasuga I, Suzuki M, Kurisu F, Furumai H. Molecular-level characterization of biodegradable organic matter causing microbial regrowth in drinking water by non-target screening using Orbitrap mass spectrometry. WATER RESEARCH 2020; 184:116130. [PMID: 32731039 DOI: 10.1016/j.watres.2020.116130] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.4] [Reference Citation Analysis] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/24/2020] [Revised: 06/14/2020] [Accepted: 06/28/2020] [Indexed: 06/11/2023]
Affiliation(s)
- Ikuro Kasuga
- Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo, 113-8656, Japan.
| | - Miyu Suzuki
- Department of Urban Engineering, School of Engineering, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo, 113-8656, Japan
| | - Futoshi Kurisu
- Research Center for Water Environment Technology, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo, 113-8656, Japan
| | - Hiroaki Furumai
- Research Center for Water Environment Technology, The University of Tokyo, 7-3-1 Hongo, Bunkyo, Tokyo, 113-8656, Japan
| |
Collapse
|
34
|
Unchartered waters: the unintended impacts of residual chlorine on water quality and biofilms. NPJ Biofilms Microbiomes 2020; 6:34. [PMID: 32978404 PMCID: PMC7519676 DOI: 10.1038/s41522-020-00144-w] [Citation(s) in RCA: 12] [Impact Index Per Article: 2.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/04/2020] [Accepted: 08/25/2020] [Indexed: 02/08/2023] Open
Abstract
Disinfection residuals in drinking water protect water quality and public heath by limiting planktonic microbial regrowth during distribution. However, we do not consider the consequences and selective pressures of such residuals on the ubiquitous biofilms that persist on the vast internal surface area of drinking water distribution systems. Using a full scale experimental facility, integrated analyses were applied to determine the physical, chemical and biological impacts of different free chlorine regimes on biofilm characteristics (composition, structure and microbiome) and water quality. Unexpectedly, higher free chlorine concentrations resulted in greater water quality degredation, observable as elevated inorganic loading and greater discolouration (a major cause of water quality complaints and a mask for other failures). High-chlorine concentrations also reduced biofilm cell concentrations but selected for a distinct biofilm bacterial community and inorganic composition, presenting unique risks. The results challenge the assumption that a measurable free chlorine residual necessarily assures drinking water safety.
Collapse
|
35
|
Buse HY, Morris BJ, Gomez-Alvarez V, Szabo JG, Hall JS. Legionella Diversity and Spatiotemporal Variation in The Occurrence of Opportunistic Pathogens within a Large Building Water System. Pathogens 2020; 9:E567. [PMID: 32668779 PMCID: PMC7400177 DOI: 10.3390/pathogens9070567] [Citation(s) in RCA: 13] [Impact Index Per Article: 2.6] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 06/08/2020] [Revised: 07/06/2020] [Accepted: 07/07/2020] [Indexed: 01/22/2023] Open
Abstract
Understanding Legionella survival mechanisms within building water systems (BWSs) is challenging due to varying engineering, operational, and water quality characteristics unique to each system. This study aimed to evaluate Legionella, mycobacteria, and free-living amoebae occurrence within a BWS over 18-28 months at six locations differing in plumbing material and potable water age, quality, and usage. A total of 114 bulk water and 57 biofilm samples were analyzed. Legionella culturability fluctuated seasonally with most culture-positive samples being collected during the winter compared to the spring, summer, and fall months. Positive and negative correlations between Legionella and L. pneumophila occurrence and other physiochemical and microbial water quality parameters varied between location and sample types. Whole genome sequencing of 19 presumptive Legionella isolates, from four locations across three time points, identified nine isolates as L. pneumophila serogroup (sg) 1 sequence-type (ST) 1; three as L. pneumophila sg5 ST1950 and ST2037; six as L. feeleii; and one as Ochrobactrum. Results showed the presence of a diverse Legionella population with consistent and sporadic occurrence at four and two locations, respectively. Viewed collectively with similar studies, this information will enable a better understanding of the engineering, operational, and water quality parameters supporting Legionella growth within BWSs.
Collapse
Affiliation(s)
- Helen Y. Buse
- Homeland Security and Materials Management Division, Center for Environmental Solutions & Emergency Response (CESER), Office of Research and Development (ORD), US Environmental Protection Agency (USEPA), Cincinnati, OH 45268, USA; (J.G.S.); (J.S.H.)
| | - Brian J. Morris
- Pegasus Technical Services, Inc c/o US EPA, Cincinnati, OH 45268, USA;
| | - Vicente Gomez-Alvarez
- Water Infrastructure Division, Center for Environmental Solutions & Emergency Response (CESER), US Environmental Protection Agency (USEPA), Office of Research and Development (ORD), Cincinnati, OH 45268, USA;
| | - Jeffrey G. Szabo
- Homeland Security and Materials Management Division, Center for Environmental Solutions & Emergency Response (CESER), Office of Research and Development (ORD), US Environmental Protection Agency (USEPA), Cincinnati, OH 45268, USA; (J.G.S.); (J.S.H.)
| | - John S. Hall
- Homeland Security and Materials Management Division, Center for Environmental Solutions & Emergency Response (CESER), Office of Research and Development (ORD), US Environmental Protection Agency (USEPA), Cincinnati, OH 45268, USA; (J.G.S.); (J.S.H.)
| |
Collapse
|
36
|
Ma B, LaPara TM, N Evans A, Hozalski RM. Effects of geographic location and water quality on bacterial communities in full-scale biofilters across North America. FEMS Microbiol Ecol 2020; 96:5698304. [PMID: 31913449 DOI: 10.1093/femsec/fiz210] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.6] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/10/2019] [Accepted: 01/07/2020] [Indexed: 11/14/2022] Open
Abstract
Spatial patterns of bacterial community composition often follow a distance-decay relationship in which community dissimilarity increases with geographic distance. Such a relationship has been commonly observed in natural environments, but less so in engineered environments. In this study, bacterial abundance and community composition in filter media samples (n = 57) from full-scale rapid biofilters at 14 water treatment facilities across North America were determined using quantitative polymerase chain reaction and Illumina HiSeq high-throughput sequencing targeting the 16S rRNA gene, respectively. Bacteria were abundant on the filter media (108.8±0.3 to 1010.7±0.2 16S rRNA gene copies/cm3 bed volume) and the bacterial communities were highly diverse (Shannon index: 5.3 ± 0.1 to 8.4 ± 0.0). Significant inter-filter variations in bacterial community composition were observed, with weighted UniFrac dissimilarity values following a weak but highly significant distance-decay relationship (z = 0.0057 ± 0.0006; P = 1.8 × 10-22). Approximately 50% of the variance in bacterial community composition was explained by the water quality parameters measured at the time of media sample collection (i.e. pH, temperature and dissolved organic carbon concentration). Overall, this study suggested that the microbiomes of biofilters are primarily shaped by geographic location and local water quality conditions but the influence of these factors on the microbiomes is tempered by filter design and operating conditions.
Collapse
Affiliation(s)
- Ben Ma
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota, 500 Pillsbury Dr. SE, Minneapolis, MN 55455, United States
| | - Timothy M LaPara
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota, 500 Pillsbury Dr. SE, Minneapolis, MN 55455, United States
- Biotechnology Institute, University of Minnesota, 1479 Gortner Ave, Saint Paul, MN 55108 , United States
| | - Ashley N Evans
- Arcadis U.S. Inc., 1717 W. 6th St. Suite 210, Austin, TX, 78703, United States
| | - Raymond M Hozalski
- Department of Civil, Environmental, and Geo- Engineering, University of Minnesota, 500 Pillsbury Dr. SE, Minneapolis, MN 55455, United States
- Biotechnology Institute, University of Minnesota, 1479 Gortner Ave, Saint Paul, MN 55108 , United States
| |
Collapse
|
37
|
Waak MB, LaPara TM, Hallé C, Hozalski RM. Nontuberculous Mycobacteria in Two Drinking Water Distribution Systems and the Role of Residual Disinfection. ENVIRONMENTAL SCIENCE & TECHNOLOGY 2019; 53:8563-8573. [PMID: 31287948 DOI: 10.1021/acs.est.9b01945] [Citation(s) in RCA: 30] [Impact Index Per Article: 5.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/09/2023]
Abstract
Nontuberculous mycobacteria (NTM) are frequently found in chloraminated drinking water distribution systems (DWDSs) due to their chloramine tolerance. NTM were investigated in the water-main biofilms and drinking water of a chloraminated DWDS in the United States (initial chloramine residual = 3.8 ± 0.1 mg L-1) and a DWDS in Norway with minimal residual disinfectant (0.08 ± 0.01 mg L-1). Total mycobacteria and Mycobacterium avium complex (MAC) were quantified by qPCR targeting, respectively, atpE genes and the internal transcribed spacer region. Mycobacteria concentrations in drinking water did not differ between the two systems (P = 0.09; up to 6 × 104 copies L-1) but were higher in the biofilms from the chloraminated DWDS (P = 5 × 10-9; up to 5 × 106 copies cm-2). MAC were not detected in either system. Sequencing of mycobacterial hsp65 genes indicated that the chloraminated DWDS lacked diversity and consisted almost exclusively of M. gordonae. In contrast, there were various novel mycobacteria in the no-residual DWDS. Finally, Mycobacterium- and Methylobacterium-like 16S rRNA genes were often detected simultaneously, though without correlation as previously observed. We conclude that, though residual chloramine may increase mycobacterial biomass in a DWDS, it may also decrease mycobacterial diversity.
Collapse
Affiliation(s)
- Michael B Waak
- Department of Civil, Environmental, and Geo-Engineering , University of Minnesota , 500 Pillsbury Dr. SE , Minneapolis , Minnesota 55455 , United States
- Department of Civil and Environmental Engineering , Norwegian University of Science and Technology , S.P. Andersens veg 5 , 7491 Trondheim , Norway
| | - Timothy M LaPara
- Department of Civil, Environmental, and Geo-Engineering , University of Minnesota , 500 Pillsbury Dr. SE , Minneapolis , Minnesota 55455 , United States
- BioTechnology Institute , University of Minnesota , 1479 Gortner Ave. , St. Paul , Minnesota 55108 , United States
| | - Cynthia Hallé
- Department of Civil and Environmental Engineering , Norwegian University of Science and Technology , S.P. Andersens veg 5 , 7491 Trondheim , Norway
| | - Raymond M Hozalski
- Department of Civil, Environmental, and Geo-Engineering , University of Minnesota , 500 Pillsbury Dr. SE , Minneapolis , Minnesota 55455 , United States
- BioTechnology Institute , University of Minnesota , 1479 Gortner Ave. , St. Paul , Minnesota 55108 , United States
| |
Collapse
|
38
|
Detection of pathogenic bacteria in hot tap water using the qPCR method: preliminary research. SN APPLIED SCIENCES 2019. [DOI: 10.1007/s42452-019-0533-1] [Citation(s) in RCA: 5] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 10/26/2022] Open
|
39
|
Waak MB, Hozalski RM, Hallé C, LaPara TM. Comparison of the microbiomes of two drinking water distribution systems-with and without residual chloramine disinfection. MICROBIOME 2019; 7:87. [PMID: 31174608 PMCID: PMC6556008 DOI: 10.1186/s40168-019-0707-5] [Citation(s) in RCA: 43] [Impact Index Per Article: 7.2] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Received: 09/28/2018] [Accepted: 05/28/2019] [Indexed: 05/10/2023]
Abstract
BACKGROUND Residual disinfection is often used to suppress biological growth in drinking water distribution systems (DWDSs), but not without undesirable side effects. In this study, water-main biofilms, drinking water, and bacteria under corrosion tubercles were analyzed from a chloraminated DWDS (USA) and a no-residual DWDS (Norway). Using quantitative real-time PCR, we quantified bacterial 16S rRNA genes and ammonia monooxygenase genes (amoA) of Nitrosomonas oligotropha and ammonia-oxidizing archaea-organisms that may contribute to chloramine loss. PCR-amplified 16S rRNA genes were sequenced to assess community taxa and diversity. RESULTS The chloraminated DWDS had lower biofilm biomass (P=1×10-6) but higher N. oligotropha-like amoA genes (P=2×10-7) than the no-residual DWDS (medians =4.7×104 and 1.1×103amoA copies cm-2, chloraminated and no residual, respectively); archaeal amoA genes were only detected in the no-residual DWDS (median =2.8×104 copies cm-2). Unlike the no-residual DWDS, biofilms in the chloraminated DWDS had lower within-sample diversity than the corresponding drinking water (P<1×10-4). Chloramine was also associated with biofilms dominated by the genera, Mycobacterium and Nitrosomonas (≤91.7% and ≤39.6% of sequences, respectively). Under-tubercle communities from both systems contained corrosion-associated taxa, especially Desulfovibrio spp. (≤98.4% of sequences). CONCLUSIONS Although residual chloramine appeared to decrease biofilm biomass and alpha diversity as intended, it selected for environmental mycobacteria and Nitrosomonas oligotropha-taxa that may pose water quality challenges. Drinking water contained common freshwater plankton and did not resemble corresponding biofilm communities in either DWDS; monitoring of tap water alone may therefore miss significant constituents of the DWDS microbiome. Corrosion-associated Desulfovibrio spp. were observed under tubercles in both systems but were particularly dominant in the chloraminated DWDS, possibly due to the addition of sulfate from the coagulant alum.
Collapse
Affiliation(s)
- Michael B. Waak
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, 500 Pillsbury Dr SE, Minneapolis, 55455 MN USA
- Department of Civil and Environmental Engineering, Norwegian University of Science and Technology, S. P. Andersens veg 5, Trondheim, 7491 Norway
| | - Raymond M. Hozalski
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, 500 Pillsbury Dr SE, Minneapolis, 55455 MN USA
- BioTechnology Institute, University of Minnesota, 1479 Gortner Ave, Saint Paul, 55108 MN USA
| | - Cynthia Hallé
- Department of Civil and Environmental Engineering, Norwegian University of Science and Technology, S. P. Andersens veg 5, Trondheim, 7491 Norway
| | - Timothy M. LaPara
- Department of Civil, Environmental, and Geo-Engineering, University of Minnesota, 500 Pillsbury Dr SE, Minneapolis, 55455 MN USA
- BioTechnology Institute, University of Minnesota, 1479 Gortner Ave, Saint Paul, 55108 MN USA
| |
Collapse
|
40
|
Kantor RS, Miller SE, Nelson KL. The Water Microbiome Through a Pilot Scale Advanced Treatment Facility for Direct Potable Reuse. Front Microbiol 2019; 10:993. [PMID: 31139160 PMCID: PMC6517601 DOI: 10.3389/fmicb.2019.00993] [Citation(s) in RCA: 23] [Impact Index Per Article: 3.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/02/2018] [Accepted: 04/18/2019] [Indexed: 01/01/2023] Open
Abstract
Advanced treatment facilities for potable water reuse of wastewater are designed to achieve high removal levels of specific pathogens, as well as many other constituents. However, changes to the microbial community throughout treatment, storage, and distribution of this water have not been well characterized. We applied high-throughput amplicon sequencing, read-based, assembly-based, and genome-resolved metagenomics, and flow cytometry to investigate the microbial communities present in a pilot-scale advanced water treatment facility. Advanced treatment of secondary-treated wastewater consisted of ozonation, chloramination, microfiltration, reverse osmosis (RO), advanced oxidation (UV/H2O2), granular activated carbon (GAC) filtration, and chlorination. Treated water was fed into bench-scale simulated distribution systems (SDS). Cell counts and microbial diversity in bulk water decreased until GAC filtration, and the bacterial communities were significantly different following each treatment step. Bacteria grew within GAC media and contributed to a consistent microbial community in the filtrate, which included members of the Rhizobiales and Mycobacteriaceae. After chlorination, some of the GAC filtrate community was maintained within the SDS, and community shifts were associated with stagnation. Putative antibiotic resistance genes and potential opportunistic pathogens were identified before RO and after advanced oxidation, although few if any members of the wastewater microbial community passed through these treatment steps. These findings can contribute to improved design of advanced treatment trains and management of microbial communities in post-treatment steps.
Collapse
Affiliation(s)
- Rose S Kantor
- Department of Civil and Environmental Engineering, University of California, Berkeley, Berkeley, CA, United States.,Engineering Research Center for Re-inventing the Nation's Urban Water Infrastructure, Berkeley, CA, United States
| | - Scott E Miller
- Department of Civil and Environmental Engineering, University of California, Berkeley, Berkeley, CA, United States.,Engineering Research Center for Re-inventing the Nation's Urban Water Infrastructure, Berkeley, CA, United States
| | - Kara L Nelson
- Department of Civil and Environmental Engineering, University of California, Berkeley, Berkeley, CA, United States.,Engineering Research Center for Re-inventing the Nation's Urban Water Infrastructure, Berkeley, CA, United States
| |
Collapse
|
41
|
Mathieu J, Yu P, Zuo P, Da Silva MLB, Alvarez PJJ. Going Viral: Emerging Opportunities for Phage-Based Bacterial Control in Water Treatment and Reuse. Acc Chem Res 2019; 52:849-857. [PMID: 30925037 DOI: 10.1021/acs.accounts.8b00576] [Citation(s) in RCA: 55] [Impact Index Per Article: 9.2] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023]
Abstract
Water security to protect human lives and support sustainable development is one of the greatest global challenges of this century. While a myriad of water pollutants can impact public health, the greatest threat arises from pathogenic bacteria that can be harbored in different components of water treatment, distribution, and reuse systems. Bacterial biofilms can also promote water infrastructure corrosion and biofouling, which substantially increase the cost and complexity of many critical operations. Conventional disinfection and microbial control approaches are often insufficient to keep up with the increasing complexity and renewed relevance of this pressing challenge. For example, common disinfectants cannot easily penetrate and eradicate biofilms, and are also relatively ineffective against resistant microorganisms. The use of chemical disinfectants is also curtailed by regulations aimed at minimizing the formation of harmful disinfection byproducts. Furthermore, disinfectants cannot be used to kill problematic bacteria in biological treatment processes without upsetting system performance. This underscores the need for novel, more precise, and more sustainable microbial control technologies. Bacteriophages (phages), which are viruses that exclusively infect bacteria, are the most abundant (and perhaps the most underutilized) biological resource on Earth, and hold great promise for targeting problematic bacteria. Although phages should not replace broad-spectrum disinfectants in drinking water treatment, they offer great potential for applications where selective targeting of problematic bacteria is warranted and antimicrobial chemicals are either relatively ineffective or their use would result in unintended detrimental consequences. Promising applications for phage-based biocontrol include selectively suppressing bulking and foaming bacteria that hinder activated sludge clarification, mitigating proliferation of antibiotic resistant strains in biological wastewater treatment systems where broad-spectrum antimicrobials would impair pollutant biodegradation, and complementing biofilm eradication efforts to delay corrosion and biofouling. Phages could also mitigate harmful cyanobacteria blooms that produce toxins in source waters, and could also serve as substitutes for the prophylactic use of antibiotics and biocides in animal agriculture to reduce their discharge to source waters and the associated selective pressure for resistant bacteria. Here, we consider the phage life cycle and its implications for bacterial control, and elaborate on the biochemical basis of such potential application niches in the water supply and reuse cycle. We also discuss potential technological barriers for phage-based bacterial control and suggest strategies and research needs to overcome them.
Collapse
Affiliation(s)
- Jacques Mathieu
- Department of Civil and Environmental Engineering, Rice University, Houston, Texas 77005, United States
| | - Pingfeng Yu
- Department of Civil and Environmental Engineering, Rice University, Houston, Texas 77005, United States
- Nanosystems Engineering Research Center for Nanotechnology-Enabled Water Treatment, Houston, Texas 77005, United States
| | - Pengxiao Zuo
- Department of Civil and Environmental Engineering, Rice University, Houston, Texas 77005, United States
| | - Marcio L. B. Da Silva
- Department of Civil and Environmental Engineering, Rice University, Houston, Texas 77005, United States
| | - Pedro J. J. Alvarez
- Department of Civil and Environmental Engineering, Rice University, Houston, Texas 77005, United States
- Nanosystems Engineering Research Center for Nanotechnology-Enabled Water Treatment, Houston, Texas 77005, United States
| |
Collapse
|