1
|
Li J, Zhang K, Han Y, Peng R, Li L, Li J, Lin G. A novel method for the preparation of reproducible, stable, and non-infectious quality control materials for Chlamydia trachomatis nucleic acid detection. Microbiol Spectr 2024; 12:e0083724. [PMID: 39373484 PMCID: PMC11536990 DOI: 10.1128/spectrum.00837-24] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/16/2024] [Accepted: 09/04/2024] [Indexed: 10/08/2024] Open
Abstract
Chlamydia trachomatis (CT) is a significant sexually transmitted pathogen known to evoke severe complications, including infertility. Nucleic acid amplification tests (NAATs) are recommended by the World Health Organization to detect CT infection. Furthermore, the establishment of methods, performance validation, internal quality control, and external quality assessment for CT NAATs necessitate the utilization of quality control materials (QCs). QCs are specimens or solutions that are analyzed for quality control purposes in a test system. In this study, we established a novel cell line that stably integrates CT amplification target sequences for producing QCs for CT NAATs. Utilizing clustered regularly interspaced short palindromic repeats/CRISPR-associated protein 9 technology, we integrated the CT plasmid-mediated sequence (comprising the full length of the cryptic plasmid and the major outer membrane protein gene, 9,136 bp) into the MUC4 gene of HEK293T cells. Positive clones were screened through flow cytometric sorting, single-cell culture, and PCR-based identification, followed by the establishment of stable cell lines. These cells were then processed using optimized cell preservation procedures to prepare QCs. The sequence insertion copy number was confirmed by real-time quantitative PCR. This novel CT QCs demonstrate excellent clinical applicability, non-infectiousness, quantifiability, and stability. With an integrated sequence exceeding 9 kb in length, it offers exceptional flexibility for adapting to new kit developments. Furthermore, maintaining a well-defined copy number and stable shelf life, the QCs closely aligns with the quality control requirements of CT NAATs. This study presents an innovative method for preparing QCs for CT nucleic acid detection, making a valuable contribution to improving the performance of CT NAATs.IMPORTANCEUntreated CT infections impose significant burdens on individuals and communities, underscoring the importance of early and accurate testing via CT NAATs for disease control. QCs are instrumental in identifying testing process issues. Hence, we developed a cell line integrating CT-amplified target sequences as readily accessible non-infectious QCs. These QCs boast several advantages: the integration of over 9 kb of CT sequence allows for broad applicability, allowing flexible adaptation to the development of new kits. Confirming the CT sequence copy number provides a reliable basis for QC concentration preparation and kit detection limit evaluation. Optimized preservation protocol enhances QC stability during storage, facilitating convenient shipment to clinical laboratories at ambient temperatures. In summary, our novel CT QCs offer a powerful tool for improving CT NAAT performance and present a fresh perspective on QC preparation for detecting nucleic acids from intracellular parasitic pathogens.
Collapse
Affiliation(s)
- Jing Li
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- Graduate School, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
| | - Kuo Zhang
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- Graduate School, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing, China
| | - Yanxi Han
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- Graduate School, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing, China
| | - Rongxue Peng
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- Graduate School, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing, China
| | - Lin Li
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- Graduate School, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing, China
| | - Jinming Li
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- Graduate School, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing, China
| | - Guigao Lin
- National Center for Clinical Laboratories, Institute of Geriatric Medicine, Chinese Academy of Medical Sciences, Beijing Hospital/National Center of Gerontology, Beijing, China
- Graduate School, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China
- Beijing Engineering Research Center of Laboratory Medicine, Beijing, China
| |
Collapse
|
2
|
Chauhan K, Kim DM, Cho E, Kim DE. Facilitation of Dye-Based Quantitative Real-Time Polymerase Chain Reaction with Poly(ethylene glycol)-Engrafted Graphene Oxide. NANOMATERIALS (BASEL, SWITZERLAND) 2023; 13:1348. [PMID: 37110934 PMCID: PMC10144433 DOI: 10.3390/nano13081348] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 03/13/2023] [Revised: 04/08/2023] [Accepted: 04/10/2023] [Indexed: 06/19/2023]
Abstract
Quantitative real-time polymerase chain reaction (qPCR) is an important and extensively utilized technique in medical and biotechnological applications. qPCR enables the real-time detection of nucleic acid during amplification, thus surpassing the necessity of post-amplification gel electrophoresis for amplicon detection. Despite being widely employed in molecular diagnostics, qPCR exhibits limitations attributed to nonspecific DNA amplification that compromises the efficiency and fidelity of qPCR. Herein, we demonstrate that poly(ethylene glycol)-engrafted nanosized graphene oxide (PEG-nGO) can significantly improve the efficiency and specificity of qPCR by adsorbing single-stranded DNA (ssDNA) without affecting the fluorescence of double-stranded DNA binding dye during DNA amplification. PEG-nGO adsorbs surplus ssDNA primers in the initial phase of PCR, having lower concentrations of DNA amplicons and thus minimizing the nonspecific annealing of ssDNA and false amplification due to primer dimerization and erroneous priming. As compared to conventional qPCR, the addition of PEG-nGO and the DNA binding dye, EvaGreen, in the qPCR setup (dubbed as PENGO-qPCR) significantly enhances the specificity and sensitivity of DNA amplification by preferential adsorption of ssDNA without inhibiting DNA polymerase activity. The PENGO-qPCR system for detection of influenza viral RNA exhibited a 67-fold higher sensitivity than the conventional qPCR setup. Thus, the performance of a qPCR can be greatly enhanced by adding PEG-nGO as a PCR enhancer as well as EvaGreen as a DNA binding dye to the qPCR mixture, which exhibits a significantly improved sensitivity of the qPCR.
Collapse
|
3
|
Ku J, Chauhan K, Hwang SH, Jeong YJ, Kim DE. Enhanced Specificity in Loop-Mediated Isothermal Amplification with Poly(ethylene glycol)-Engrafted Graphene Oxide for Detection of Viral Genes. BIOSENSORS 2022; 12:bios12080661. [PMID: 36005057 PMCID: PMC9405610 DOI: 10.3390/bios12080661] [Citation(s) in RCA: 12] [Impact Index Per Article: 4.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 07/29/2022] [Revised: 08/17/2022] [Accepted: 08/17/2022] [Indexed: 11/16/2022]
Abstract
Loop-mediated isothermal amplification (LAMP) is a nucleic acid amplification method that allows the simple, quick, and low-cost detection of various viral genes. LAMP assays are susceptible to generating non-specific amplicons, as high concentrations of DNA primers can give rise to primer dimerization and mismatched hybridizations, resulting in false-positive signals. Herein, we reported that poly(ethylene glycol)-engrafted nanosized graphene oxide (PEG-nGO) can significantly enhance the specificity of LAMP, owing to its ability to adsorb single-stranded DNA (ssDNA). By adsorbing surplus ssDNA primers, PEG-nGO minimizes the non-specific annealing of ssDNAs, including erroneous priming and primer dimerization, leading to the enhanced specificity of LAMP. The detection of complementary DNAs transcribed from the hepatitis C virus (HCV) RNA was performed by the PEG-nGO-based LAMP. We observed that the inclusion of PEG-nGO significantly enhances the specificity and sensitivity of the LAMP assay through the augmented difference in fluorescence signals between the target and non-target samples. The PEG-nGO-based LAMP assay greatly facilitates the detection of HCV-positive clinical samples, with superior precision to the conventional quantitative real-time PCR (RT-qPCR). Among the 20 clinical samples tested, all 10 HCV-positive samples are detected as positive in the PEG-nGO-based LAMP, while only 7 samples are detected as HCV-positive in the RT-qPCR. In addition, the PEG-nGO-based LAMP method significantly improves the detection precision for the false-positive decision by 1.75-fold as compared to the LAMP without PEG-nGO. Thus, PEG-nGO can significantly improve the performance of LAMP assays by facilitating the specific amplification of target DNA with a decrease in background signal.
Collapse
Affiliation(s)
- Jamin Ku
- Department of Bioscience and Biotechnology, Konkuk University, 120 Neungdong-ro, Gwangjin-gu, Seoul 05902, Korea
| | - Khushbu Chauhan
- Department of Bioscience and Biotechnology, Konkuk University, 120 Neungdong-ro, Gwangjin-gu, Seoul 05902, Korea
| | - Sang-Hyun Hwang
- Department of Laboratory Medicine, Asan Medical Center, University of Ulsan College of Medicine, Seoul 05505, Korea
| | - Yong-Joo Jeong
- School of Applied Chemistry, Kookmin University, Seoul 02707, Korea
- Correspondence: (Y.-J.J.); (D.-E.K.)
| | - Dong-Eun Kim
- Department of Bioscience and Biotechnology, Konkuk University, 120 Neungdong-ro, Gwangjin-gu, Seoul 05902, Korea
- Correspondence: (Y.-J.J.); (D.-E.K.)
| |
Collapse
|
4
|
Trick AY, Ngo HT, Nambiar AH, Morakis MM, Chen FE, Chen L, Hsieh K, Wang TH. Filtration-assisted magnetofluidic cartridge platform for HIV RNA detection from blood. LAB ON A CHIP 2022; 22:945-953. [PMID: 35088790 PMCID: PMC9035341 DOI: 10.1039/d1lc00820j] [Citation(s) in RCA: 16] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/10/2023]
Abstract
The ability to detect and quantify HIV RNA in blood is essential to sensitive detection of infections and monitoring viremia throughout treatment. Current options for point-of-care HIV diagnosis (i.e. lateral flow rapid tests) lack sensitivity for early detection and are unable to quantify viral load. HIV RNA diagnostics typically require extensive pre-processing of blood to isolate plasma and extract nucleic acids, in addition to expensive equipment for conducting nucleic acid amplification and fluorescence detection. Therefore, molecular HIV diagnostics is still mainly limited to clinical laboratories and there is an unmet need for high sensitivity point-of-care screening and at-home HIV viral load quantification. In this work, we outline a streamlined workflow for extraction of plasma from whole blood coupled with HIV RNA extraction and quantitative polymerase chain reaction (qPCR) in a portable magnetofluidic cartridge platform for use at the point-of-care. Viral particles were isolated from blood using manual filtration through a 3D-printed filter module in seconds followed by automated nucleic acid capture, purification, and transfer to qPCR using magnetic beads. Both nucleic acid extraction and qPCR were integrated within cartridges using compact instrumentation consisting of a motorized magnet arm, miniaturized thermocycler, and image-based fluorescence detection. We demonstrated detection down to 1000 copies of HIV viral particles from whole blood in <30 minutes.
Collapse
Affiliation(s)
- Alexander Y Trick
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
| | - Hoan Thanh Ngo
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
| | - Anju H Nambiar
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
| | - Marisa M Morakis
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
| | - Fan-En Chen
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
| | - Liben Chen
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
| | - Kuangwen Hsieh
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
| | - Tza-Huei Wang
- Department of Biomedical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA.
- Department of Mechanical Engineering, Johns Hopkins University, Baltimore, MD 21218, USA
- Institute for NanoBioTechnology, Johns Hopkins University, Baltimore, MD 21218, USA
| |
Collapse
|
5
|
Xue Z, You M, Peng P, Tong H, He W, Li A, Mao P, Xu T, Xu F, Yao C. Taqman-MGB nanoPCR for Highly Specific Detection of Single-Base Mutations. Int J Nanomedicine 2021; 16:3695-3705. [PMID: 34113098 PMCID: PMC8185130 DOI: 10.2147/ijn.s310254] [Citation(s) in RCA: 10] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/09/2021] [Accepted: 05/11/2021] [Indexed: 12/12/2022] Open
Abstract
PURPOSE Detection of single-base mutations is important for real-time monitoring of tumor progression, therapeutic effects, and drug resistance. However, the specific detection of single-base mutations from excessive wild-type background sequences with routine PCR technology remains challenging. Our objective is to develop a simple and highly specific qPCR-based single-base mutation detection method. METHODS Using EGRF T790M as a model, gold nanoparticles at different concentrations were separately added into the Taqman-MGB qPCR system to test specificity improvement, leading to the development of the optimal Taqman-MGB nanoPCR system. Then, these optimal conditions were used to test the range of improvement in the specificity of mutant-type and wild-type templates and the detection limit of mutation abundances in a spiked sample. RESULTS The Taqman-MGB nanoPCR was established based on the traditional qPCR, with significantly suppressed background noise and improved specificity for single-base mutation detection. With EGFR T790M as a template, we demonstrated that our Taqman-MGB nanoPCR system could improve specificity across a wide concentration range from 10-9 μM to 10 μM and detect as low as 0.95% mutation abundance in spiked samples, which is lower than what the traditional Taqman-MGB qPCR and existing PCR methods can detect. Moreover, we also proposed an experimentally validated barrier hypothesis for the mechanism of improved specificity. CONCLUSION The developed Taqman-MGB nanoPCR system could be a powerful tool for clinical single-base mutation detection.
Collapse
Affiliation(s)
- Zhenrui Xue
- Department of Transfusion Medicine, Southwest Hospital, Third Military Medical University, Army Medical University, Chongqing, 400038, People’s Republic of China
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
| | - Minli You
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
| | - Ping Peng
- Department of Transfusion Medicine, Southwest Hospital, Third Military Medical University, Army Medical University, Chongqing, 400038, People’s Republic of China
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
| | - Haoyang Tong
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
| | - Wanghong He
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
| | - Ang Li
- Key Laboratory of Shaanxi Province for Craniofacial Precision Medicine Research, College of Stomatology, Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
| | - Ping Mao
- Department of Transfusion Medicine, Southwest Hospital, Third Military Medical University, Army Medical University, Chongqing, 400038, People’s Republic of China
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
| | - Ting Xu
- Department of Transfusion Medicine, Southwest Hospital, Third Military Medical University, Army Medical University, Chongqing, 400038, People’s Republic of China
| | - Feng Xu
- The Key Laboratory of Biomedical Information Engineering of Ministry of Education, School of Life Science and Technology, Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
- Bioinspired Engineering and Biomechanics Center (BEBC), Xi’an Jiaotong University, Xi’an, 710049, People’s Republic of China
| | - Chunyan Yao
- Department of Transfusion Medicine, Southwest Hospital, Third Military Medical University, Army Medical University, Chongqing, 400038, People’s Republic of China
| |
Collapse
|
6
|
Rasheed AK, Siddiqui R, Ahmed SMK, Gabriel S, Jalal MZ, John A, Khan NA. hBN Nanoparticle-Assisted Rapid Thermal Cycling for the Detection of Acanthamoeba. Pathogens 2020; 9:pathogens9100824. [PMID: 33036480 PMCID: PMC7601326 DOI: 10.3390/pathogens9100824] [Citation(s) in RCA: 4] [Impact Index Per Article: 0.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 08/13/2020] [Revised: 10/02/2020] [Accepted: 10/03/2020] [Indexed: 11/16/2022] Open
Abstract
Acanthamoeba are widely distributed in the environment and are known to cause blinding keratitis and brain infections with greater than 90% mortality rate. Currently, polymerase chain reaction (PCR) is a highly sensitive and promising technique in Acanthamoeba detection. Remarkably, the rate of heating-cooling and convective heat transfer of the PCR tube is limited by low thermal conductivity of the reagents mixture. The addition of nanoparticles to the reaction has been an interesting approach that could augment the thermal conductivity of the mixture and subsequently enhance heat transfer through the PCR tube. Here, we have developed hexagonal boron nitride (hBN) nanoparticle-based PCR assay for the rapid detection of Acanthamoeba to amplify DNA from low amoeba cell density. As low as 1 × 10-4 wt % was determined as the optimum concentration of hBN nanoparticles, which increased Acanthamoeba DNA yield up to ~16%. Further, it was able to reduce PCR temperature that led to a ~2.0-fold increase in Acanthamoeba DNA yield at an improved PCR specificity at 46.2 °C low annealing temperature. hBN nanoparticles further reduced standard PCR step time by 10 min and cycles by eight; thus, enhancing Acanthamoeba detection rapidly. Enhancement of Acanthamoeba PCR DNA yield is possibly due to the high adsorption affinity of hBN nanoparticles to purine (Guanine-G) due to the higher thermal conductivity achieved in the PCR mixture due to the addition of hBN. Although further research is needed to demonstrate these findings in clinical application, we propose that the interfacial layers, Brownian motion, and percolation network contribute to the enhanced thermal conductivity effect.
Collapse
Affiliation(s)
- Abdul Khaliq Rasheed
- Department of New Energy Science and Engineering, School of Energy and Chemical Engineering, Xiamen University Malaysia Campus, Bandar Sunsuria, Sepang 43900, Malaysia;
| | - Ruqaiyyah Siddiqui
- Department of Biology, Chemistry and Environmental Sciences, College of Arts and Sciences, American University of Sharjah, Sharjah 26666, UAE;
| | - Salma Mohammed Kabir Ahmed
- Department of Biological Sciences, School of Science and Technology, Sunway University, Bandar Sunway 47500, Malaysia; (S.M.K.A.); (S.G.)
| | - Shobana Gabriel
- Department of Biological Sciences, School of Science and Technology, Sunway University, Bandar Sunway 47500, Malaysia; (S.M.K.A.); (S.G.)
| | - Mohammed Zayan Jalal
- Department of Mechanical Engineering, Faculty of Engineering, International Islamic University Malaysia, Jalan Gombak 53100, Malaysia;
| | - Akbar John
- Institute of Oceanography and Maritime Studies, Kulliyyah of Science, International Islamic University Malaysia, Kuantan 25200, Malaysia;
| | - Naveed Ahmed Khan
- Department of Biology, Chemistry and Environmental Sciences, College of Arts and Sciences, American University of Sharjah, Sharjah 26666, UAE;
- Correspondence: ; Tel.: +971-6515-4752
| |
Collapse
|
7
|
Kim JW, Kim M, Lee KK, Chung KH, Lee CS. Effects of Graphene Oxide-Gold Nanoparticles Nanocomposite on Highly Sensitive Foot-and-Mouth Disease Virus Detection. NANOMATERIALS 2020; 10:nano10101921. [PMID: 32993046 PMCID: PMC7601864 DOI: 10.3390/nano10101921] [Citation(s) in RCA: 9] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Subscribe] [Scholar Register] [Received: 09/02/2020] [Revised: 09/21/2020] [Accepted: 09/23/2020] [Indexed: 11/29/2022]
Abstract
The polymerase chain reaction (PCR) has become a powerful molecular diagnostic technique over the past few decades, but remains somewhat impaired due to low specificity, poor sensitivity, and false positive results. Metal and carbon nanomaterials, quantum dots, and metal oxides, can improve the quality and productivity of PCR assays. Here, we describe the ability of PCR assisted with nanomaterials (nano-PCR) comprising a nanocomposite of graphene oxide (GO) and gold nanoparticles (AuNPs) for sensitive detection of the foot-and-mouth disease virus (FMDV). Graphene oxide and AuNPs have been widely applied as biomedical materials for diagnosis, therapy, and drug delivery due to their unique chemical and physical properties. Foot-and-mouth disease (FMD) is highly contagious and fatal for cloven-hoofed animals including pigs, and it can thus seriously damage the swine industry. Therefore, a highly sensitive, specific, and practical method is needed to detect FMDV. The detection limit of real-time PCR improved by ~1000 fold when assisted by GO-AuNPs. We also designed a system of detecting serotypes in a single assay based on melting temperatures. Our sensitive and specific nano-PCR system can be applied to diagnose early FMDV infection, and thus may prove to be useful for clinical and biomedical applications.
Collapse
Affiliation(s)
- Jong-Won Kim
- Bionanotechnology Research Center, Korea Research Institute of Bioscience & Biotechnology (KRIBB) 125 Gwahak-ro, Yuseong-gu, Daejeon 34141, Korea; (J.-W.K.); (M.K.); (K.K.L.)
- Dignostics Platform Research Section, Electronics and Telecommunications Research Institute (ETRI) 218 Gajeong-ro, Yuseong-gu, Daejeon 34129, Korea;
| | - Myeongkun Kim
- Bionanotechnology Research Center, Korea Research Institute of Bioscience & Biotechnology (KRIBB) 125 Gwahak-ro, Yuseong-gu, Daejeon 34141, Korea; (J.-W.K.); (M.K.); (K.K.L.)
- Dignostics Platform Research Section, Electronics and Telecommunications Research Institute (ETRI) 218 Gajeong-ro, Yuseong-gu, Daejeon 34129, Korea;
| | - Kyung Kwan Lee
- Bionanotechnology Research Center, Korea Research Institute of Bioscience & Biotechnology (KRIBB) 125 Gwahak-ro, Yuseong-gu, Daejeon 34141, Korea; (J.-W.K.); (M.K.); (K.K.L.)
- Dignostics Platform Research Section, Electronics and Telecommunications Research Institute (ETRI) 218 Gajeong-ro, Yuseong-gu, Daejeon 34129, Korea;
- Department of Life and Nanopharmaceutical Science, College of Pharmacy, Kyung Hee University, Seoul 02447, Korea
| | - Kwang Hyo Chung
- Dignostics Platform Research Section, Electronics and Telecommunications Research Institute (ETRI) 218 Gajeong-ro, Yuseong-gu, Daejeon 34129, Korea;
| | - Chang-Soo Lee
- Bionanotechnology Research Center, Korea Research Institute of Bioscience & Biotechnology (KRIBB) 125 Gwahak-ro, Yuseong-gu, Daejeon 34141, Korea; (J.-W.K.); (M.K.); (K.K.L.)
- Dignostics Platform Research Section, Electronics and Telecommunications Research Institute (ETRI) 218 Gajeong-ro, Yuseong-gu, Daejeon 34129, Korea;
- Department of Biotechnology, University of Science & Technology (UST), Daejeon 34113, Korea
- Correspondence:
| |
Collapse
|
8
|
Maleki MJ, Ghasemi Y, Pourhassan-Moghaddam M, Asadi N, Dadashpour M, Abolghasem Mohammadi S, Akbarzadeh A, Zarghami N. Effect of green GO/Au nanocomposite on in-vitro amplification of human DNA. IET Nanobiotechnol 2019; 13:887-890. [PMID: 31811755 DOI: 10.1049/iet-nbt.2018.5082] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/07/2023] Open
Abstract
Recently nanomaterials have attracted interest for increasing efficiency of polymerase chain reaction (PCR) systems. Here, the authors report on the usefulness of green graphene oxide/gold (GO/Au) nanocomposites for enhancement of PCR reactions. In this study, green GO/Au nanocomposite was prepared with Matricaria chamomilla extract as reducing/capping agent for site-directed nucleation of Auo atoms on surface of GO sheets. The as-prepared green GO/Au nanocomposites were then characterised with UV-VIS spectrophotometer and scanning electron microscopy. Later, the effect of these nanocomposites was studied on end-point and real-time PCR employed for amplification of human glyceraldehyde-3-phosphate dehydrogenase gene. The results indicated that GO/Au nanocomposite can improve both end-point and real-time PCR methods at the optimum concentrations, possibly through interaction between GO/Au nanocomposite and the materials in PCR reaction, and through providing increased thermal convection by the GO surface as well as the Au nanostructures. In conclusion, it can be suggested that green GO/Au nanocomposite is a biocompatible and eco-friendly candidate as enhancer of in-vitro molecular amplification strategies.
Collapse
Affiliation(s)
- Mohammad Jafar Maleki
- Department of Medical Biotechnology, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Yaghoob Ghasemi
- Department of Medical Biotechnology, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mohammad Pourhassan-Moghaddam
- Department of Medical Biotechnology, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran.
| | - Nahideh Asadi
- Department of Medical Nanotechnology, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | - Mehdi Dadashpour
- Department of Medical Biotechnology, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| | | | - Abolfazl Akbarzadeh
- Department of Chemical Engineering, Northeastern University, 360 Huntington Avenue, Boston, Massachusetts 02115-5000, USA
| | - Nosratollah Zarghami
- Department of Medical Biotechnology, Faculty of Advanced Medical Sciences, Tabriz University of Medical Sciences, Tabriz, Iran
| |
Collapse
|
9
|
Sun C, Cheng Y, Pan Y, Yang J, Wang X, Xia F. Efficient polymerase chain reaction assisted by metal-organic frameworks. Chem Sci 2019; 11:797-802. [PMID: 34123055 PMCID: PMC8145698 DOI: 10.1039/c9sc03202a] [Citation(s) in RCA: 15] [Impact Index Per Article: 2.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 01/02/2023] Open
Abstract
As a powerful tool for obtaining sufficient DNA from rare DNA resources, polymerase chain reaction (PCR) has been widely used in various fields, and the optimization of PCR is still in progress due to the dissatisfactory specificity, sensitivity and efficiency. Although many nanomaterials have been proven to be capable of optimizing PCR, their underlying mechanisms are still unclear. So far, the scientifically compelling and functionally evolving metal–organic framework (MOF) materials with high specific surface area, tunable pore sizes, alterable surface charges and favourable thermal conductivity have not been used for PCR optimization. In this study, UiO-66 and ZIF-8 were used to optimize error-prone two round PCR. The results demonstrated that UiO-66 and ZIF-8 not only enhanced the sensitivity and efficiency of the first round PCR, but also increased the specificity and efficiency of the second round PCR. Moreover, they could widen the annealing temperature range of the second round PCR. The interaction of DNA and Taq polymerase with MOFs may be the main reason. This work provided a candidate enhancer for PCR, deepened our understanding on the enhancement mechanisms of nano-PCR, and explored a new application field for MOFs. Many new materials have the ability to optimize polymerase chain reaction (PCR). Metal-organic frame materials UiO-66 and ZIF-8 can enhance sensitivity, specificity and efficiency of PCR, indicating their potential as PCR enhancers.![]()
Collapse
Affiliation(s)
- Chunli Sun
- Hubei Key Laboratory of Bioinorganic Chemistry & Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology Wuhan 430074 China
| | - Yong Cheng
- School of Materials Science and Engineering, Huazhong University of Science and Technology Wuhan 430074 China
| | - Yong Pan
- Hubei Key Laboratory of Bioinorganic Chemistry & Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology Wuhan 430074 China
| | - Juliang Yang
- Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences Wuhan 430074 China
| | - Xudong Wang
- Hubei Key Laboratory of Bioinorganic Chemistry & Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology Wuhan 430074 China
| | - Fan Xia
- Hubei Key Laboratory of Bioinorganic Chemistry & Materia Medica, School of Chemistry and Chemical Engineering, Huazhong University of Science and Technology Wuhan 430074 China .,Engineering Research Center of Nano-Geomaterials of Ministry of Education, Faculty of Materials Science and Chemistry, China University of Geosciences Wuhan 430074 China
| |
Collapse
|
10
|
Lin Q, Ye X, Huang Z, Yang B, Fang X, Chen H, Kong J. Graphene Oxide-Based Suppression of Nonspecificity in Loop-Mediated Isothermal Amplification Enabling the Sensitive Detection of Cyclooxygenase-2 mRNA in Colorectal Cancer. Anal Chem 2019; 91:15694-15702. [PMID: 31725282 DOI: 10.1021/acs.analchem.9b03861] [Citation(s) in RCA: 16] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Cyclooxygenase-2 (COX2) mRNA represents a key biomarker for identifying subjects with colorectal cancer (CRC), while there is still no rapid and sensitive detection method for COX2 mRNA. Loop-mediated isothermal amplification (LAMP) is extensively developed for the amplification of nucleic acids; however, its application is frequently hindered by serious nonspecific amplification. Herein, this work reported a graphene oxide (GO)-based LAMP method to enable the one-step detection of COX2 mRNA in cancer cells and serum samples. We found that GO greatly enhanced the specificity of LAMP through decreasing nonspecific hybridization and the fluorescence background signal because of the simultaneous adsorption of single-stranded primers and DNA staining dyes on GO. The detection limit of developed GO-based LAMP was 2 orders of magnitude more sensitive compared to that of classical LAMP. Then a GO-based reverse transcription (RT)-LAMP strategy was further developed and applied to detect COX2 mRNA in CRC cancer cells and serum samples with high specificity. The GO-based LAMP platform with advantages of low cost, simplicity, high specificity, and sensitivity holds considerable potential for real-time fluorescence monitoring of nucleic acid amplification in a wide range of fields.
Collapse
Affiliation(s)
- Qiuyuan Lin
- Department of Chemistry , Fudan University , Shanghai 200438 , P. R. China
| | - Xin Ye
- Department of Chemistry , Fudan University , Shanghai 200438 , P. R. China
| | - Zhipeng Huang
- Department of Chemistry , Fudan University , Shanghai 200438 , P. R. China
| | - Bin Yang
- Department of Chemistry , Fudan University , Shanghai 200438 , P. R. China
| | - Xueen Fang
- Department of Chemistry , Fudan University , Shanghai 200438 , P. R. China
| | - Hui Chen
- Department of Chemistry , Fudan University , Shanghai 200438 , P. R. China
| | - Jilie Kong
- Department of Chemistry , Fudan University , Shanghai 200438 , P. R. China
| |
Collapse
|
11
|
Preparation of multifunctional PEG-graft-Halloysite Nanotubes for Controlled Drug Release, Tumor Cell Targeting, and Bio-imaging. Colloids Surf B Biointerfaces 2018; 170:322-329. [DOI: 10.1016/j.colsurfb.2018.06.042] [Citation(s) in RCA: 36] [Impact Index Per Article: 5.1] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/12/2018] [Revised: 06/11/2018] [Accepted: 06/19/2018] [Indexed: 11/20/2022]
|
12
|
Wang M, Gustafsson OJR, Siddiqui G, Javed I, Kelly HG, Blin T, Yin H, Kent SJ, Creek DJ, Kempe K, Ke PC, Davis TP. Human plasma proteome association and cytotoxicity of nano-graphene oxide grafted with stealth polyethylene glycol and poly(2-ethyl-2-oxazoline). NANOSCALE 2018; 10:10863-10875. [PMID: 29658020 DOI: 10.1039/c8nr00835c] [Citation(s) in RCA: 38] [Impact Index Per Article: 5.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/08/2023]
Abstract
Polyethylene glycol (PEG) is a gold standard against protein fouling. However, recent studies have revealed surprising adverse effects of PEG, namely its immunogenicity and shortened bio-circulation upon repeated dosing. This highlights a crucial need to further examine 'stealth' polymers for controlling the protein 'corona', a new challenge in nanomedicine and bionanotechnology. Poly(2-ethyl-2-oxazoline) (PEtOx) is another primary form of stealth polymer that, despite its excellent hydrophilicity and biocompatibility, has found considerably less applications compared with PEG. Herein, we performed label-free proteomics to compare the associations of linear PEG- and PEtOx-grafted nano-graphene oxide (nGO) sheets with human plasma proteins, complemented by cytotoxicity and haemolysis assays to compare the cellular interactions of these polymers. Our data revealed that nGO-PEG enriched apolipoproteins, while nGO-PEtOx displayed a preferred binding with pro-angiogenic and structural proteins, despite high similarities in their respective top-10 enriched proteins. In addition, nGO-PEG and nGO-PEtOx exhibited similar levels of enrichment of complement proteins. Both PEG and PEtOx markedly reduced nGO toxicity to HEK 293 cells while mitigating nGO haemolysis. This study provides the first detailed profile of the human plasma protein corona associated with PEtOx-grafted nanomaterials and, in light of the distinctions of PEtOx in chemical adaptability, in vivo clearance and immunogenicity, validates the use of PEtOx as a viable stealth alternative to PEG for nanomedicines and bionanotechnologies.
Collapse
Affiliation(s)
- Miaoyi Wang
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC 3052, Australia.
| | - Ove J R Gustafsson
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Future Industries Institute, University of South Australia, University Boulevard, Mawson Lakes, SA 5095, Australia
| | - Ghizal Siddiqui
- Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC 3052, Australia
| | - Ibrahim Javed
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC 3052, Australia.
| | - Hannah G Kelly
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, The University of Melbourne, Melbourne, VIC 3000, Australia and Department of Microbiology and Immunology, Peter Doherty Institute for Infection and Immunity, The University of Melbourne, Melbourne, VIC 3000, Australia
| | - Thomas Blin
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC 3052, Australia.
| | - Hong Yin
- CSIRO Manufacturing, Bayview Avenue, Clayton, VIC 3168, Australia
| | - Stephen J Kent
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, The University of Melbourne, Melbourne, VIC 3000, Australia and Department of Microbiology and Immunology, Peter Doherty Institute for Infection and Immunity, The University of Melbourne, Melbourne, VIC 3000, Australia and Melbourne Sexual Health Centre and Department of Infectious Diseases, Alfred Health, Central Clinical School, Monash University, Melbourne, Australia
| | - Darren J Creek
- Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC 3052, Australia
| | - Kristian Kempe
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC 3052, Australia.
| | - Pu Chun Ke
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC 3052, Australia.
| | - Thomas P Davis
- ARC Centre of Excellence in Convergent Bio-Nano Science and Technology, Monash Institute of Pharmaceutical Sciences, Monash University, 381 Royal Parade, Parkville, VIC 3052, Australia. and Department of Chemistry, University of Warwick, Gibbet Hill, Coventry, CV4 7AL, UK
| |
Collapse
|
13
|
Wang L, Huang Z, Wang R, Liu Y, Qian C, Wu J, Liu J. Transition Metal Dichalcogenide Nanosheets for Visual Monitoring PCR Rivaling a Real-Time PCR Instrument. ACS APPLIED MATERIALS & INTERFACES 2018; 10:4409-4418. [PMID: 29327589 DOI: 10.1021/acsami.7b15746] [Citation(s) in RCA: 8] [Impact Index Per Article: 1.1] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/07/2023]
Abstract
Monitoring the progress of polymerase chain reactions (PCRs) is of critical importance in bioanalytical chemistry and molecular biology. Although real-time PCR thermocyclers are ideal for this purpose, their high cost has limited their applications in resource-poor areas. Direct visual detection would be a more attractive alternative. To monitor the PCR amplification, DNA-staining dyes, such as SYBR Green I (SG), are often used. Although these dyes give higher fluorescence when binding to double-stranded DNA products, they also yield strong background fluorescence in the presence of a high concentration of single-stranded (ss) DNA primers. In this work, we screened various nanomaterials and found that graphene oxide (GO), reduced GO, molybdenum disulfide (MoS2), and tungsten disulfide (WS2) can quench the fluorescence of nonamplified negative samples while still retaining strong fluorescence of positive ones. The signal ratio of positive-over-negative samples was enhanced by around 50-fold in the presence of these materials. In particular, MoS2 and WS2 nearly fully retained the fluorescence of the positive samples. The mechanism for MoS2 and WS2 to enhance PCR signaling is attributed to the adsorption of both the ssDNA PCR primers and SG with an appropriate strength. MoS2 can also suppress nonspecific amplification caused by excess polymerase. Finally, this method was used to detect extracted transgenic soya GTS 40-3-2 DNA after PCR amplification. Compared with the samples without nanomaterials, the addition of MoS2 could better distinguish the concentration difference of the template DNA, and the sensitivity of visual detection rivaled that from a real-time PCR instrument.
Collapse
Affiliation(s)
- Liu Wang
- College of Biosystems Engineering and Food Science, Zhejiang University , Hangzhou 310058, China
- Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo , Waterloo N2L 3G1, Ontario, Canada
| | - Zhicheng Huang
- Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo , Waterloo N2L 3G1, Ontario, Canada
| | - Rui Wang
- College of Biosystems Engineering and Food Science, Zhejiang University , Hangzhou 310058, China
| | - Yibo Liu
- Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo , Waterloo N2L 3G1, Ontario, Canada
| | - Cheng Qian
- College of Biosystems Engineering and Food Science, Zhejiang University , Hangzhou 310058, China
| | - Jian Wu
- College of Biosystems Engineering and Food Science, Zhejiang University , Hangzhou 310058, China
| | - Juewen Liu
- Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo , Waterloo N2L 3G1, Ontario, Canada
| |
Collapse
|
14
|
Baek A, Baek YM, Kim HM, Jun BH, Kim DE. Polyethylene Glycol-Engrafted Graphene Oxide as Biocompatible Materials for Peptide Nucleic Acid Delivery into Cells. Bioconjug Chem 2018; 29:528-537. [PMID: 29376329 DOI: 10.1021/acs.bioconjchem.8b00025] [Citation(s) in RCA: 37] [Impact Index Per Article: 5.3] [Reference Citation Analysis] [Abstract] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/12/2022]
Abstract
Graphene oxide (GO) is known to strongly bind single-stranded nucleic acids with fluorescence quenching near the GO surface. However, GO exhibits weak biocompatibility characteristics, such as low dispersibility in cell culture media and significant cytotoxicity. To improve dispersibility in cell culture media and cell viability of GO, we prepared nanosized GO (nGO) constructs and modified the nGO surface using polyethylene glycol (PEG-nGO). Single-stranded peptide nucleic acid (PNA) was adsorbed onto the PEG-nGO and was readily desorbed by adding complementary RNA or under low pH conditions. PNA adsorbed on the PEG-nGO was efficiently delivered into lung cancer cells via endocytosis without affecting cell viability. Furthermore, antisense PNA delivered using PEG-nGO effectively downregulated the expression of the target gene in cancer cells. Our results suggest that PEG-nGO is a biocompatible carrier useful for PNA delivery into cells and serves as a promising gene delivery tool.
Collapse
Affiliation(s)
- Ahruem Baek
- Department of Bioscience and Biotechnology, Konkuk University Neundong-ro 120, Gwangjin-gu, Seoul 05029, Republic of Korea
| | - Yu Mi Baek
- Department of Bioscience and Biotechnology, Konkuk University Neundong-ro 120, Gwangjin-gu, Seoul 05029, Republic of Korea
| | - Hyung-Mo Kim
- Department of Bioscience and Biotechnology, Konkuk University Neundong-ro 120, Gwangjin-gu, Seoul 05029, Republic of Korea
| | - Bong-Hyun Jun
- Department of Bioscience and Biotechnology, Konkuk University Neundong-ro 120, Gwangjin-gu, Seoul 05029, Republic of Korea
| | - Dong-Eun Kim
- Department of Bioscience and Biotechnology, Konkuk University Neundong-ro 120, Gwangjin-gu, Seoul 05029, Republic of Korea
| |
Collapse
|
15
|
Sang F, Zhang Z, Yuan L, Liu D. Quantum dots for a high-throughput Pfu polymerase based multi-round polymerase chain reaction (PCR). Analyst 2018; 143:1259-1267. [DOI: 10.1039/c7an01764b] [Citation(s) in RCA: 3] [Impact Index Per Article: 0.4] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/21/2022]
Abstract
We developed a Pfu polymerase based multi-round PCR technique assisted by quantum dots (QDs).
Collapse
Affiliation(s)
- Fuming Sang
- School of Marine Science and Technology
- Harbin Institute of Technology
- Weihai
- People's Republic of China
| | - Zhizhou Zhang
- School of Marine Science and Technology
- Harbin Institute of Technology
- Weihai
- People's Republic of China
| | - Lin Yuan
- School of Marine Science and Technology
- Harbin Institute of Technology
- Weihai
- People's Republic of China
| | - Deli Liu
- School of Marine Science and Technology
- Harbin Institute of Technology
- Weihai
- People's Republic of China
| |
Collapse
|