1
|
Sui B, Liu C, Sun Z, Zheng Y, Zhou W, Liu H. CRISPR/Cas12a-based transition state molecular switch for low-background detection of HPV-16 on a microfluidic platform. Int J Biol Macromol 2025; 311:143556. [PMID: 40306523 DOI: 10.1016/j.ijbiomac.2025.143556] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/29/2025] [Revised: 04/23/2025] [Accepted: 04/25/2025] [Indexed: 05/02/2025]
Abstract
Human papillomavirus type 16 (HPV-16) is a high-risk oncogenic subtype of HPV, strongly associated with the pathogenesis of multiple cancers. Researchers have developed many detection methods for HPV-16, among which, the detection method based on microfluidic has the characteristics of high efficiency and high sensitivity. However, non-specific adsorption remains a critical challenge, often leading to elevated background signals. Here, we propose an On-Chip assay integrated by transition state molecular switch based on CRISPR-Cas12a (OCTMS-CRISPR) for stable, sensitive, and low-background fluorescence detection of HPV-16. This system leverages a highly integrated molecular switch and Cas12a to perform dual-screening, while the dissociation products of the molecular switch activate trans-cleavage activity. Our data suggest that OCTMS-CRISPR suppresses background signals on microfluidic chip while maintaining the specificity and sensitivity of trans-cleavage. For demonstration, we detected five HPV subtypes and base mismatches at varying positions and quantities. The LOD can reach 7.64 pM (average fluorescence intensity) and 9.91fM (pixel counting), showing great potential in the field of biosensing and DNA chips.
Collapse
Affiliation(s)
- Boren Sui
- Institute for Advanced Interdisciplinary Research (iAIR), School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China
| | - Chunhong Liu
- Institute for Advanced Interdisciplinary Research (iAIR), School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China
| | - Zhiwei Sun
- Institute for Advanced Interdisciplinary Research (iAIR), School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China
| | - Yang Zheng
- Institute for Advanced Interdisciplinary Research (iAIR), School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China
| | - Weijia Zhou
- Institute for Advanced Interdisciplinary Research (iAIR), School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China
| | - Haiyun Liu
- Institute for Advanced Interdisciplinary Research (iAIR), School of Chemistry and Chemical Engineering, University of Jinan, Jinan 250022, PR China.
| |
Collapse
|
2
|
Aslan M, Seymour E, Brickner H, Clark AE, Celebi I, Townsend MB, Satheshkumar PS, Riley M, Carlin AF, Ünlü MS, Ray P. A label-free optical biosensor-based point-of-care test for the rapid detection of Monkeypox virus. Biosens Bioelectron 2025; 269:116932. [PMID: 39550778 DOI: 10.1016/j.bios.2024.116932] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/02/2024] [Revised: 10/09/2024] [Accepted: 11/10/2024] [Indexed: 11/19/2024]
Abstract
Diagnostic approaches that combine the high sensitivity and specificity of laboratory-based digital detection with the ease of use and affordability of point-of-care (POC) technologies could revolutionize disease diagnostics. This is especially true in infectious disease diagnostics, where rapid and accurate pathogen detection is critical to curbing the spread of disease. We have pioneered an innovative label-free digital detection platform that utilizes Interferometric Reflectance Imaging Sensor (IRIS) technology. IRIS leverages light interference from an optically transparent thin film, eliminating the need for complex optical resonances to enhance the signal by harnessing light interference and the power of signal averaging in shot-noise-limited operation In our latest work, we have further improved our previous 'Single-Particle' IRIS (SP-IRIS) technology by allowing the construction of the optical signature of target nanoparticles (whole virus) from a single image. This new platform, 'Pixel-Diversity' IRIS (PD-IRIS), eliminated the need for z-scan acquisition, required in SP-IRIS, a time-consuming and expensive process, and made our technology more applicable to POC settings. Using PD-IRIS, we quantitatively detected the Monkeypox virus (MPXV), the etiological agent for Monkeypox (Mpox) infection. MPXV was captured by anti-A29 monoclonal antibody (mAb 69-126-3) on Protein G spots on the sensor chips and were detected at a limit-of-detection (LOD) - of 200 PFU/mL (∼3.3 aM). PD-IRIS was superior to the laboratory-based ELISA (LOD - 1800 PFU/mL) used as a comparator. The specificity of PD-IRIS in MPXV detection was demonstrated using Herpes simplex virus, type 1 (HSV-1), and Cowpox virus (CPXV). This work establishes the effectiveness of PD-IRIS and opens possibilities for its advancement in clinical diagnostics of Mpox at POC. Moreover, PD-IRIS is a modular technology that can be adapted for the multiplex detection of pathogens for which high-affinity ligands are available that can bind their surface antigens to capture them on the sensor surface.
Collapse
Affiliation(s)
- Mete Aslan
- Department of Electrical and Computer Engineering, Boston University, Boston, MA, 02215, USA
| | - Elif Seymour
- iRiS Kinetics, Boston University, Business Incubation Center, Boston, MA, 02215, USA
| | - Howard Brickner
- Department of Medicine, Division of Infectious Diseases and Global Public Health, University of California, San Diego, CA, 92093, USA
| | - Alex E Clark
- Department of Medicine, Division of Infectious Diseases and Global Public Health, University of California, San Diego, CA, 92093, USA
| | - Iris Celebi
- Department of Electrical and Computer Engineering, Boston University, Boston, MA, 02215, USA
| | - Michael B Townsend
- Poxvirus and Rabies Branch, Centers for Disease Control and Prevention, Atlanta, GA, 30329, USA
| | | | | | - Aaron F Carlin
- Department of Medicine, Division of Infectious Diseases and Global Public Health, University of California, San Diego, CA, 92093, USA; Department of Pathology, University of California, San Diego, CA, 92093, USA
| | - M Selim Ünlü
- Department of Electrical and Computer Engineering, Boston University, Boston, MA, 02215, USA; Department of Biomedical Engineering, Boston University, Boston, MA, 02215, USA.
| | - Partha Ray
- Department of Medicine, Division of Infectious Diseases and Global Public Health, University of California, San Diego, CA, 92093, USA.
| |
Collapse
|
3
|
Hu XG, Zhao Y, Peng Y, Chen XM, Wang LF, Lin ZT, Zhao J, Hu S. In-situ label-free temperature-compensated DNA hybridization detection with a fiber-optic interferometer and a fiber Bragg grating for microfluidic chip. Biosens Bioelectron 2023; 242:115703. [PMID: 37820556 DOI: 10.1016/j.bios.2023.115703] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2023] [Revised: 09/04/2023] [Accepted: 09/20/2023] [Indexed: 10/13/2023]
Abstract
We demonstrated a temperature-compensated optofluidic DNA biosensor available for microfluidic chip. The optofluidic sensor was composed of an interferometer and a fiber Bragg grating (FBG) by femtosecond laser direct writing micro/nano processing technology. The sensing arm of the interferometer was suspended on the inner wall of the microchannel and could directly interact with the microfluid. With the immobilization of the single stranded probe DNA (pDNA), this optofluidic biosensor could achieve specific detection of single stranded complementary DNA (scDNA). The experimental results indicated that a linear response within 50 nM and the detection limit of 1.87 nM were achieved. In addition, the optofluidic biosensor could simultaneously monitor temperature to avoid temperature fluctuations interfering with the DNA hybridization detection process. And, the optofluidic detection channel could achieve fast sample replacement within 10 s at a flow rate of 2 μL/min and sample consumption only required nanoliters. This optofluidic DNA biosensor had the advantages of label-free, good specificity, dual parameter detection, low sample consumption, fast response, and easy repeatable preparation, which was of great significance for the field of DNA hybridization research and solving the temperature sensitivity problem of biosensors and had good prospects in biological analysis.
Collapse
Affiliation(s)
- Xu-Guang Hu
- College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China
| | - Yong Zhao
- College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China; State Key Laboratory of Synthetical Automation for Process Industries, Shenyang, 110819, China; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, China.
| | - Yun Peng
- College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, China
| | - Xiao-Ming Chen
- College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, China
| | - Lu-Feng Wang
- College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China
| | - Zi-Ting Lin
- College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China
| | - Jian Zhao
- College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China
| | - Sheng Hu
- College of Information Science and Engineering, Northeastern University, Shenyang, 110819, China; Hebei Key Laboratory of Micro-Nano Precision Optical Sensing and Measurement Technology, Qinhuangdao, 066004, China
| |
Collapse
|
4
|
Zhao Z, Zharnikov M. Exploiting epoxy-rich poly(ethylene glycol) films for highly selective ssDNA sensing via electrochemical impedance spectroscopy. Phys Chem Chem Phys 2023; 25:26538-26548. [PMID: 37752830 DOI: 10.1039/d3cp03851c] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 09/28/2023]
Abstract
This study introduces an alternative approach to immobilize thiolated single-stranded DNA (ssDNA) for the DNA sensing. In contrast to the standard, monomolecular assembly of such moieties on gold substrate, over the thiolate-gold anchors, we propose to use bioinert, porous polyethylene glycol (PEG) films as a 3D template for ssDNA immobilization. The latter process relies on the reaction between the thiol group of the respectively decorated ssDNA and the epoxy groups in the epoxy-rich PEG matrix. The immobilization process and subsequent hybridization ability of the resulting sensing assembly were monitored using cyclic voltammetry and electrochemical impedance spectroscopy, with the latter tool proving itself as the most suitable transduction technique. Electrochemical data confirmed the successful immobilization of thiol-decorated ssDNA probes into the PEG matrix over the thiol-epoxy linkage as well as high hybridization efficiency, selectivity, and sensitivity of the resulting DNA sensor. Whereas this sensor was equivalent to the direct ssDNA assembly in terms of the efficiency, it exhibited a better selectivity and bioinert properties in view of the bioinert character of the PEG matrix. The above findings place PEG films as a promising platform for highly selective ssDNA sensing, leveraging their flexible chemistry, 3D character, and bioinert properties.
Collapse
Affiliation(s)
- Zhiyong Zhao
- Angewandte Physikalische Chemie, Universität Heidelberg, Im Neuenheimer Feld 253, 69120 Heidelberg, Germany.
| | - Michael Zharnikov
- Angewandte Physikalische Chemie, Universität Heidelberg, Im Neuenheimer Feld 253, 69120 Heidelberg, Germany.
| |
Collapse
|
5
|
Nava G, Casiraghi L, Carzaniga T, Zanchetta G, Chiari M, Damin F, Bollati V, Signorini L, Delbue S, Bellini T, Buscaglia M. Digital Detection of Single Virus Particles by Multi-Spot, Label-Free Imaging Biosensor on Anti-Reflective Glass. SMALL (WEINHEIM AN DER BERGSTRASSE, GERMANY) 2023; 19:e2300947. [PMID: 37060208 DOI: 10.1002/smll.202300947] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.5] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 02/02/2023] [Revised: 03/21/2023] [Indexed: 06/19/2023]
Abstract
Rapid detection of whole virus particles in biological or environmental samples represents an unmet need for the containment of infectious diseases. Here, an optical device enabling the enumeration of single virion particles binding on antibody or aptamers immobilized on a surface with anti-reflective coating is described. In this regime, nanoparticles adhering to the sensor surface provide localized contributions to the reflected field that become detectable because of their mixing with the interfering waves in the reflection direction. Thus, these settings are exploited to realize a scan-free, label-free, micro-array-type digital assay on a disposable cartridge, in which the virion counting takes place in wide field-of-view imaging. With this approach we could quantify, by enumeration, different variants of SARS-CoV-2 virions interacting with antibodies and aptamers immobilized on different spots. For all tested variants, the aptamers showed larger affinity but lower specificity relative to the antibodies. It is found that the combination of different probes on the same surface enables increasing specificity of detection and dynamic range.
Collapse
Affiliation(s)
- Giovanni Nava
- Dipartimento di Biotecnologie Mediche e Medicina Traslazionale, Universitá degli Studi di Milano, via F.lli Cervi, 93, Segrate, Milano, 20054, Italy
| | - Luca Casiraghi
- Dipartimento di Biotecnologie Mediche e Medicina Traslazionale, Universitá degli Studi di Milano, via F.lli Cervi, 93, Segrate, Milano, 20054, Italy
| | - Thomas Carzaniga
- Dipartimento di Biotecnologie Mediche e Medicina Traslazionale, Universitá degli Studi di Milano, via F.lli Cervi, 93, Segrate, Milano, 20054, Italy
| | - Giuliano Zanchetta
- Dipartimento di Biotecnologie Mediche e Medicina Traslazionale, Universitá degli Studi di Milano, via F.lli Cervi, 93, Segrate, Milano, 20054, Italy
| | - Marcella Chiari
- Istituto di Scienze e Tecnologie Chimiche "Giulio Natta", National Research Council of Italy (SCITEC-CNR), via Mario Bianco 11, Milano, 20131, Italy
| | - Francesco Damin
- Istituto di Scienze e Tecnologie Chimiche "Giulio Natta", National Research Council of Italy (SCITEC-CNR), via Mario Bianco 11, Milano, 20131, Italy
| | - Valentina Bollati
- Dipartimento di Scienze Cliniche e di Comunitá, Universitá degli Studi di Milano, via S. Barnaba 8, Milano, 20122, Italy
| | - Lucia Signorini
- Dipartimento di Scienze Biomediche, Chirurgiche ed Odontoiatriche, Universitá degli Studi di Milano, via Pascal 36, Milano, 20133, Italy
| | - Serena Delbue
- Dipartimento di Scienze Biomediche, Chirurgiche ed Odontoiatriche, Universitá degli Studi di Milano, via Pascal 36, Milano, 20133, Italy
| | - Tommaso Bellini
- Dipartimento di Biotecnologie Mediche e Medicina Traslazionale, Universitá degli Studi di Milano, via F.lli Cervi, 93, Segrate, Milano, 20054, Italy
| | - Marco Buscaglia
- Dipartimento di Biotecnologie Mediche e Medicina Traslazionale, Universitá degli Studi di Milano, via F.lli Cervi, 93, Segrate, Milano, 20054, Italy
| |
Collapse
|
6
|
Seymour E, Ekiz Kanik F, Diken Gür S, Bakhshpour-Yucel M, Araz A, Lortlar Ünlü N, Ünlü MS. Solid-Phase Optical Sensing Techniques for Sensitive Virus Detection. SENSORS (BASEL, SWITZERLAND) 2023; 23:5018. [PMID: 37299745 PMCID: PMC10255700 DOI: 10.3390/s23115018] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Received: 04/18/2023] [Revised: 05/15/2023] [Accepted: 05/16/2023] [Indexed: 06/12/2023]
Abstract
Viral infections can pose a major threat to public health by causing serious illness, leading to pandemics, and burdening healthcare systems. The global spread of such infections causes disruptions to every aspect of life including business, education, and social life. Fast and accurate diagnosis of viral infections has significant implications for saving lives, preventing the spread of the diseases, and minimizing social and economic damages. Polymerase chain reaction (PCR)-based techniques are commonly used to detect viruses in the clinic. However, PCR has several drawbacks, as highlighted during the recent COVID-19 pandemic, such as long processing times and the requirement for sophisticated laboratory instruments. Therefore, there is an urgent need for fast and accurate techniques for virus detection. For this purpose, a variety of biosensor systems are being developed to provide rapid, sensitive, and high-throughput viral diagnostic platforms, enabling quick diagnosis and efficient control of the virus's spread. Optical devices, in particular, are of great interest due to their advantages such as high sensitivity and direct readout. The current review discusses solid-phase optical sensing techniques for virus detection, including fluorescence-based sensors, surface plasmon resonance (SPR), surface-enhanced Raman scattering (SERS), optical resonators, and interferometry-based platforms. Then, we focus on an interferometric biosensor developed by our group, the single-particle interferometric reflectance imaging sensor (SP-IRIS), which has the capability to visualize single nanoparticles, to demonstrate its application for digital virus detection.
Collapse
Affiliation(s)
- Elif Seymour
- Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON M4P 1R2, Canada;
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA;
| | - Fulya Ekiz Kanik
- Department of Electrical Engineering, Boston University, Boston, MA 02215, USA; (F.E.K.); (M.B.-Y.)
| | - Sinem Diken Gür
- Department of Biology, Hacettepe University, Ankara 06800, Türkiye;
| | - Monireh Bakhshpour-Yucel
- Department of Electrical Engineering, Boston University, Boston, MA 02215, USA; (F.E.K.); (M.B.-Y.)
- Department of Chemistry, Bursa Uludag University, Bursa 16059, Türkiye
| | - Ali Araz
- Department of Chemistry, Dokuz Eylül University, Izmir 35390, Türkiye;
| | - Nese Lortlar Ünlü
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA;
| | - M. Selim Ünlü
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA;
- Department of Electrical Engineering, Boston University, Boston, MA 02215, USA; (F.E.K.); (M.B.-Y.)
| |
Collapse
|
7
|
Li W, Lu W, Liu Z. A phosphatase-recruiting bispecific antibody-aptamer chimera for enhanced suppression of tumor growth. Chem Commun (Camb) 2023; 59:6572-6575. [PMID: 37170857 DOI: 10.1039/d3cc01137b] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 05/13/2023]
Abstract
The development of agents against abnormal activation of receptor tyrosine kinases (RTKs) for therapeutic interventions is in high demand. Using mesenchymal epithelial transition (Met) protein as a proof-of-concept RTK, here we developed a CD148-recruiting bispecific antibody-aptamer chimera for simultaneous inhibition of extra- and intra-cellular functions of Met in cancer cells. This chimera exhibited remarkable migration-suppressive and antiproliferative effects. This strategy is highly promising for developing kinase inhibitors for use in therapies of a broad range of cancers.
Collapse
Affiliation(s)
- Wei Li
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China.
| | - Weihua Lu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China.
| | - Zhen Liu
- State Key Laboratory of Analytical Chemistry for Life Science, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210023, China.
| |
Collapse
|
8
|
Zheng Y, Song X, Fredj Z, Bian S, Sawan M. Challenges and perspectives of multi-virus biosensing techniques: A review. Anal Chim Acta 2023; 1244:340860. [PMID: 36737150 PMCID: PMC9868144 DOI: 10.1016/j.aca.2023.340860] [Citation(s) in RCA: 11] [Impact Index Per Article: 5.5] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 10/10/2022] [Revised: 01/17/2023] [Accepted: 01/18/2023] [Indexed: 01/24/2023]
Abstract
In the context of globalization, individuals have an increased chance of being infected by multiple viruses simultaneously, thereby highlighting the importance of developing multiplexed devices. In addition to sufficient sensitivity and rapid response, multi-virus sensing techniques are expected to offer additional advantages including high throughput, one-time sampling for parallel analysis, and full automation with data visualization. In this paper, we review the optical, electrochemical, and mechanical platforms that enable multi-virus biosensing. The working mechanisms of each platform, including the detection principle, transducer configuration, bio-interface design, and detected signals, are reviewed. The advantages and limitations, as well as the challenges in implementing various detection strategies in real-life scenarios, were evaluated. Future perspectives on multiplexed biosensing techniques are critically discussed. Earlier access to multi-virus biosensors will efficiently serve for immediate pandemic control, such as in emerging SARS-CoV-2 and monkeypox cases.
Collapse
Affiliation(s)
- Yuqiao Zheng
- Zhejiang University, Hangzhou, 310058, Zhejiang, China,Research Center for Industries of the Future, Westlake University, Hangzhou, Zhejiang, 310030, China
| | - Xixi Song
- Research Center for Industries of the Future, Westlake University, Hangzhou, Zhejiang, 310030, China
| | - Zina Fredj
- Research Center for Industries of the Future, Westlake University, Hangzhou, Zhejiang, 310030, China
| | - Sumin Bian
- Research Center for Industries of the Future, Westlake University, Hangzhou, Zhejiang, 310030, China.
| | - Mohamad Sawan
- Research Center for Industries of the Future, Westlake University, Hangzhou, Zhejiang, 310030, China.
| |
Collapse
|
9
|
Bakhshpour-Yucel M, Gür SD, Seymour E, Aslan M, Lortlar Ünlü N, Ünlü MS. Highly-Sensitive, Label-Free Detection of Microorganisms and Viruses via Interferometric Reflectance Imaging Sensor. MICROMACHINES 2023; 14:281. [PMID: 36837980 PMCID: PMC9960798 DOI: 10.3390/mi14020281] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 12/06/2022] [Revised: 01/08/2023] [Accepted: 01/18/2023] [Indexed: 06/18/2023]
Abstract
Pathogenic microorganisms and viruses can easily transfer from one host to another and cause disease in humans. The determination of these pathogens in a time- and cost-effective way is an extreme challenge for researchers. Rapid and label-free detection of pathogenic microorganisms and viruses is critical in ensuring rapid and appropriate treatment. Sensor technologies have shown considerable advancements in viral diagnostics, demonstrating their great potential for being fast and sensitive detection platforms. In this review, we present a summary of the use of an interferometric reflectance imaging sensor (IRIS) for the detection of microorganisms. We highlight low magnification modality of IRIS as an ensemble biomolecular mass measurement technique and high magnification modality for the digital detection of individual nanoparticles and viruses. We discuss the two different modalities of IRIS and their applications in the sensitive detection of microorganisms and viruses.
Collapse
Affiliation(s)
- Monireh Bakhshpour-Yucel
- Department of Electrical Engineering, Photonics Center, Boston University, Boston, MA 02215, USA
- Department of Chemistry, Faculty of Science and Art, Bursa Uludag University, Bursa 16059, Turkey
| | - Sinem Diken Gür
- Department of Biotechnology, Hacettepe University, Ankara 06800, Turkey
| | - Elif Seymour
- Lunenfeld-Tanenbaum Research Institute, Mount Sinai Hospital, Toronto, ON M5G 1X5, Canada
| | - Mete Aslan
- Department of Electrical Engineering, Photonics Center, Boston University, Boston, MA 02215, USA
| | - Nese Lortlar Ünlü
- Department of Biomedical Engineering, Photonics Center, Boston University, Boston, MA 02215, USA
| | - M. Selim Ünlü
- Department of Electrical Engineering, Photonics Center, Boston University, Boston, MA 02215, USA
- Department of Biomedical Engineering, Photonics Center, Boston University, Boston, MA 02215, USA
| |
Collapse
|
10
|
Seymour E, Ünlü MS, Connor JH. A high-throughput single-particle imaging platform for antibody characterization and a novel competition assay for therapeutic antibodies. Sci Rep 2023; 13:306. [PMID: 36609657 PMCID: PMC9821353 DOI: 10.1038/s41598-022-27281-w] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Grants] [Track Full Text] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 07/26/2022] [Accepted: 12/29/2022] [Indexed: 01/07/2023] Open
Abstract
Monoclonal antibodies (mAbs) play an important role in diagnostics and therapy of infectious diseases. Here we utilize a single-particle interferometric reflectance imaging sensor (SP-IRIS) for screening 30 mAbs against Ebola, Sudan, and Lassa viruses (EBOV, SUDV, and LASV) to find out the ideal capture antibodies for whole virus detection using recombinant vesicular stomatitis virus (rVSV) models expressing surface glycoproteins (GPs) of EBOV, SUDV, and LASV. We also make use of the binding properties on SP-IRIS to develop a model for mapping the antibody epitopes on the GP structure. mAbs that bind to mucin-like domain or glycan cap of the EBOV surface GP show the highest signal on SP-IRIS, followed by mAbs that target the GP1-GP2 interface at the base domain. These antibodies were shown to be highly efficacious against EBOV infection in non-human primates in previous studies. For LASV detection, 8.9F antibody showed the best performance on SP-IRIS. This antibody binds to a unique region on the surface GP compared to other 15 mAbs tested. In addition, we demonstrate a novel antibody competition assay using SP-IRIS and rVSV-EBOV models to reveal the competition between mAbs in three successful therapeutic mAb cocktails against EBOV infection. We provide an explanation as to why ZMapp cocktail has higher efficacy compared to the other two cocktails by showing that three mAbs in this cocktail (13C6, 2G4, 4G7) do not compete with each other for binding to EBOV GP. In fact, the binding of 13C6 enhances the binding of 2G4 and 4G7 antibodies. Our results establish SP-IRIS as a versatile tool that can provide high-throughput screening of mAbs, multiplexed and sensitive detection of viruses, and evaluation of therapeutic antibody cocktails.
Collapse
Affiliation(s)
- Elif Seymour
- Department of Biomedical Engineering, Boston University, Boston, MA, 02215, USA
- Lunenfeld-Tanenbaum Research Institute, Sinai Health System, Toronto, ON, M5G 1X5, Canada
| | - M Selim Ünlü
- Department of Biomedical Engineering, Boston University, Boston, MA, 02215, USA
- Department of Electrical and Computer Engineering, Boston University, Boston, MA, 02215, USA
| | - John H Connor
- Department of Microbiology, Boston University School of Medicine, Boston, MA, 02118, USA.
| |
Collapse
|
11
|
Attomolar sensitivity microRNA detection using real-time digital microarrays. Sci Rep 2022; 12:16220. [PMID: 36171215 PMCID: PMC9519543 DOI: 10.1038/s41598-022-19912-z] [Citation(s) in RCA: 0] [Impact Index Per Article: 0] [Reference Citation Analysis] [Abstract] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 04/28/2022] [Accepted: 09/06/2022] [Indexed: 11/08/2022] Open
Abstract
MicroRNAs (miRNAs) are a family of noncoding, functional RNAs. With recent developments in molecular biology, miRNA detection has attracted significant interest, as hundreds of miRNAs and their expression levels have shown to be linked to various diseases such as infections, cardiovascular disorders and cancers. A powerful and high throughput tool for nucleic acid detection is the DNA microarray technology. However, conventional methods do not meet the demands in sensitivity and specificity, presenting significant challenges for the adaptation of miRNA detection for diagnostic applications. In this study, we developed a highly sensitive and multiplexed digital microarray using plasmonic gold nanorods as labels. For proof of concept studies, we conducted experiments with two miRNAs, miRNA-451a (miR-451) and miRNA-223-3p (miR-223). We demonstrated improvements in sensitivity in comparison to traditional end-point assays that employ capture on solid phase support, by implementing real-time tracking of the target molecules on the sensor surface. Particle tracking overcomes the sensitivity limitations for detection of low-abundance biomarkers in the presence of low-affinity but high-abundance background molecules, where endpoint assays fall short. The absolute lowest measured concentration was 100 aM. The measured detection limit being well above the blank samples, we performed theoretical calculations for an extrapolated limit of detection (LOD). The dynamic tracking improved the extrapolated LODs from femtomolar range to \documentclass[12pt]{minimal}
\usepackage{amsmath}
\usepackage{wasysym}
\usepackage{amsfonts}
\usepackage{amssymb}
\usepackage{amsbsy}
\usepackage{mathrsfs}
\usepackage{upgreek}
\setlength{\oddsidemargin}{-69pt}
\begin{document}$$\sim$$\end{document}∼ 10 attomolar (less than 1300 copies in 0.2 ml of sample) for both miRNAs and the total incubation time was decreased from 5 h to 35 min.
Collapse
|
12
|
Nava G, Zanchetta G, Giavazzi F, Buscaglia M. Label-free optical biosensors in the pandemic era. NANOPHOTONICS (BERLIN, GERMANY) 2022; 11:4159-4181. [PMID: 39634532 PMCID: PMC11502114 DOI: 10.1515/nanoph-2022-0354] [Citation(s) in RCA: 6] [Impact Index Per Article: 2.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Figures] [Subscribe] [Scholar Register] [Received: 06/17/2022] [Accepted: 08/01/2022] [Indexed: 12/07/2024]
Abstract
The research in the field of optical biosensors is continuously expanding, thanks both to the introduction of brand new technologies and the ingenious use of established methods. A new awareness on the potential societal impact of this research has arisen as a consequence of the Covid-19 pandemic. The availability of a new generation of analytical tools enabling a more accurate understanding of bio-molecular processes or the development of distributed diagnostic devices with improved performance is now in greater demand and more clearly envisioned, but not yet achieved. In this review, we focus on emerging innovation opportunities conveyed by label-free optical biosensors. We review the most recent innovations in label-free optical biosensor technology in consideration of their competitive potential in selected application areas. The operational simplicity implicit to label-free detection can be exploited in novel rapid and compact devices for distributed diagnostic applications. The adaptability to any molecular recognition or conformational process facilitates the integration of DNA nanostructures carrying novel functions. The high sensitivity to nanoscale objects stimulates the development of ultrasensitive systems down to digital detection of single molecular binding events enhanced by nanoparticles and direct enumeration of bio-nanoparticles like viruses.
Collapse
Affiliation(s)
- Giovanni Nava
- Dipartimento di Biotecnologie Mediche e Medicina Traslazionale, Università degli Studi di Milano, Segrate, MI, Italy
| | - Giuliano Zanchetta
- Dipartimento di Biotecnologie Mediche e Medicina Traslazionale, Università degli Studi di Milano, Segrate, MI, Italy
| | - Fabio Giavazzi
- Dipartimento di Biotecnologie Mediche e Medicina Traslazionale, Università degli Studi di Milano, Segrate, MI, Italy
| | - Marco Buscaglia
- Dipartimento di Biotecnologie Mediche e Medicina Traslazionale, Università degli Studi di Milano, Segrate, MI, Italy
| |
Collapse
|
13
|
Kim HJ, Park D, Park Y, Kim DH, Kim J. Electric-Field-Mediated In-Sensor Alignment of Antibody's Orientation to Enhance the Antibody-Antigen Binding for Ultrahigh Sensitivity Sensors. NANO LETTERS 2022; 22:6537-6544. [PMID: 35900218 DOI: 10.1021/acs.nanolett.2c01584] [Citation(s) in RCA: 8] [Impact Index Per Article: 2.7] [Reference Citation Analysis] [Abstract] [Key Words] [MESH Headings] [Track Full Text] [Subscribe] [Scholar Register] [Indexed: 06/15/2023]
Abstract
Applying an electric-field (E-field) during antibody immobilization aligns the orientation of the antibody on the biosensor surface, thereby enhancing the binding probability between the antibody and antigen and maximizing the sensitivity of the biosensor. In this study, a biosensor with enhanced antibody-antigen binding probability was developed using the alignment of polar antibodies (immunoglobulin G [IgG]) under an E-field applied inside the interdigitated electrodes. The optimal alignment condition was first theoretically calculated and then experimentally confirmed by comparing the impedance change before and after the alignment of IgG (a purified anti-β-amyloid antibody). With the optimized condition, the impedance change of the biosensor was maximized because of the alignment of IgG orientation on the sensor surface; the detection sensitivity of the antigen amyloid-beta 1-42 was also maximized. The E-field-based in-sensor alignment of antibodies is an easy and effective method for enhancing biosensor sensitivity.
Collapse
Affiliation(s)
- Hye Jin Kim
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea
- Institute of Chemical Processes (ICP), Seoul National University, Seoul 08826, Republic of Korea
| | - Dongsung Park
- Department of Clinical Pharmacology and Therapeutics, College of Medicine, Kyung Hee University, Seoul 02447, Republic of Korea
| | - Yejin Park
- Department of Medical Biotechnology, College of Life Science and Biotechnology, Dongguk University, Seoul 04620, Republic of Korea
| | - Dae-Hyeong Kim
- Center for Nanoparticle Research, Institute for Basic Science (IBS), Seoul 08826, Republic of Korea
- Department of Materials Science and Engineering, Seoul National University, Seoul 08826, Republic of Korea
| | - Jinsik Kim
- Department of Medical Biotechnology, College of Life Science and Biotechnology, Dongguk University, Seoul 04620, Republic of Korea
| |
Collapse
|
14
|
Li N, Wang X, Tibbs J, Che C, Peinetti AS, Zhao B, Liu L, Barya P, Cooper L, Rong L, Wang X, Lu Y, Cunningham BT. Label-Free Digital Detection of Intact Virions by Enhanced Scattering Microscopy. J Am Chem Soc 2022; 144:1498-1502. [PMID: 34928591 PMCID: PMC9762554 DOI: 10.1021/jacs.1c09579] [Citation(s) in RCA: 18] [Impact Index Per Article: 6.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 02/04/2023]
Abstract
Several applications in health diagnostics, food, safety, and environmental monitoring require rapid, simple, selective, and quantitatively accurate viral load monitoring. Here, we introduce the first label-free biosensing method that rapidly detects and quantifies intact virus in human saliva with single-virion resolution. Using pseudotype SARS-CoV-2 as a representative target, we immobilize aptamers with the ability to differentiate active from inactive virions on a photonic crystal, where the virions are captured through affinity with the spike protein displayed on the outer surface. Once captured, the intrinsic scattering of the virions is amplified and detected through interferometric imaging. Our approach analyzes the motion trajectory of each captured virion, enabling highly selective recognition against nontarget virions, while providing a limit of detection of 1 × 103 copies/mL at room temperature. The approach offers an alternative to enzymatic amplification assays for point-of-collection diagnostics.
Collapse
Affiliation(s)
- Nantao Li
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Xiaojing Wang
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Joseph Tibbs
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Congnyu Che
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Ana Sol Peinetti
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Bin Zhao
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Leyang Liu
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Priyash Barya
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Laura Cooper
- Department of Microbiology and Immunology, College of Medicine, University of Illinois at Chicago, Chicago, Illinois 60612, United States
| | - Lijun Rong
- Department of Microbiology and Immunology, College of Medicine, University of Illinois at Chicago, Chicago, Illinois 60612, United States
| | - Xing Wang
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Yi Lu
- Department of Chemistry, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| | - Brian T Cunningham
- Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Nick Holonyak Jr. Micro and Nanotechnology Laboratory, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Department of Bioengineering, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Carl R. Woese Institute for Genomic Biology, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
- Cancer Center at Illinois, University of Illinois at Urbana-Champaign, Urbana, Illinois 61801, United States
| |
Collapse
|
15
|
Jin X, Fu R, Du W, Shan X, Mao Z, Deng A, Lin X, Su Y, Yang H, Lv W, Zhong H, Huang G. Rapid, Highly Sensitive, and Label-Free Pathogen Assay System Using a Solid-Phase Self-Interference Recombinase Polymerase Amplification Chip and Hyperspectral Interferometry. Anal Chem 2022; 94:2926-2933. [PMID: 35107980 DOI: 10.1021/acs.analchem.1c04858] [Citation(s) in RCA: 10] [Impact Index Per Article: 3.3] [Reference Citation Analysis] [Abstract] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 12/26/2022]
Abstract
Recombinase polymerase amplification (RPA) is a useful pathogen identification method. Several label-free detection methods for RPA amplicons have been developed in recent years. However, these methods still lack sensitivity, specificity, efficiency, or simplicity. In this study, we propose a rapid, highly sensitive, and label-free pathogen assay system based on a solid-phase self-interference RPA chip (SiSA-chip) and hyperspectral interferometry. The SiSA-chips amplify and capture RPA amplicons on the chips, rather than irrelevant amplicons such as primer dimers, and the SiSA-chips are then analysed by hyperspectral interferometry. Optical length increases of SiSA-chips are used to demonstrate RPA detection results, with a limit of detection of 1.90 nm. This assay system can detect as few as six copies of the target 18S rRNA gene of Plasmodium falciparum within 20 min, with a good linear relationship between the detection results and the concentration of target genes (R2 = 0.9903). Single nucleotide polymorphism (SNP) genotyping of the dhfr gene of Plasmodium falciparum is also possible using the SiSA-chip, with as little as 1% of mutant gene distinguished from wild-type loci (m/wt). This system offers a high-efficiency (20 min), high-sensitivity (6 copies/reaction), high-specificity (1% m/wt), and low-cost (∼1/50 of fluorescence assays for RPA) diagnosis method for pathogen DNA identification. Therefore, this system is promising for fast identification of pathogens to help diagnose infectious diseases, including SNP genotyping.
Collapse
Affiliation(s)
- Xiangyu Jin
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Rongxin Fu
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Wenli Du
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Xiaohui Shan
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Zeyin Mao
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Anni Deng
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Xue Lin
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Ya Su
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Han Yang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Wenqi Lv
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Hao Zhong
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China
| | - Guoliang Huang
- Department of Biomedical Engineering, School of Medicine, Tsinghua University, Beijing 100084, China.,National Engineering Research Center for Beijing Biochip Technology, Beijing 102206, China
| |
Collapse
|
16
|
Ramoji A, Pahlow S, Pistiki A, Rueger J, Shaik TA, Shen H, Wichmann C, Krafft C, Popp J. Understanding Viruses and Viral Infections by Biophotonic Methods. TRANSLATIONAL BIOPHOTONICS 2022. [DOI: 10.1002/tbio.202100008] [Citation(s) in RCA: 1] [Impact Index Per Article: 0.3] [Reference Citation Analysis] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Indexed: 11/06/2022] Open
Affiliation(s)
- Anuradha Ramoji
- Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Helmholtzweg 4 Jena Germany
- Leibniz Institute of Photonic Technology Jena (a member of Leibniz Health Technologies) , Albert‐Einstein Str. 9 Jena Germany
- Center for Sepsis Control and Care Jena University Hospital, Am Klinikum 1, 07747 Jena Germany
| | - Susanne Pahlow
- Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Helmholtzweg 4 Jena Germany
- Leibniz Institute of Photonic Technology Jena (a member of Leibniz Health Technologies) , Albert‐Einstein Str. 9 Jena Germany
- InfectoGnostics Research Campus Jena, Philosophenweg 7, 07743 Jena Germany
| | - Aikaterini Pistiki
- Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Helmholtzweg 4 Jena Germany
- Leibniz Institute of Photonic Technology Jena (a member of Leibniz Health Technologies) , Albert‐Einstein Str. 9 Jena Germany
| | - Jan Rueger
- Leibniz Institute of Photonic Technology Jena (a member of Leibniz Health Technologies) , Albert‐Einstein Str. 9 Jena Germany
| | - Tanveer Ahmed Shaik
- Leibniz Institute of Photonic Technology Jena (a member of Leibniz Health Technologies) , Albert‐Einstein Str. 9 Jena Germany
| | - Haodong Shen
- Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Helmholtzweg 4 Jena Germany
- Leibniz Institute of Photonic Technology Jena (a member of Leibniz Health Technologies) , Albert‐Einstein Str. 9 Jena Germany
- InfectoGnostics Research Campus Jena, Philosophenweg 7, 07743 Jena Germany
| | - Christina Wichmann
- Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Helmholtzweg 4 Jena Germany
- Leibniz Institute of Photonic Technology Jena (a member of Leibniz Health Technologies) , Albert‐Einstein Str. 9 Jena Germany
- InfectoGnostics Research Campus Jena, Philosophenweg 7, 07743 Jena Germany
| | - Christoph Krafft
- Leibniz Institute of Photonic Technology Jena (a member of Leibniz Health Technologies) , Albert‐Einstein Str. 9 Jena Germany
| | - Juergen Popp
- Institute of Physical Chemistry and Abbe Center of Photonics, Friedrich Schiller University, Helmholtzweg 4 Jena Germany
- Leibniz Institute of Photonic Technology Jena (a member of Leibniz Health Technologies) , Albert‐Einstein Str. 9 Jena Germany
- Center for Sepsis Control and Care Jena University Hospital, Am Klinikum 1, 07747 Jena Germany
- InfectoGnostics Research Campus Jena, Philosophenweg 7, 07743 Jena Germany
| |
Collapse
|
17
|
Chiodi E, Marn AM, Bakhshpour M, Lortlar Ünlü N, Ünlü MS. The Effects of Three-Dimensional Ligand Immobilization on Kinetic Measurements in Biosensors. Polymers (Basel) 2022; 14:polym14020241. [PMID: 35054650 PMCID: PMC8777619 DOI: 10.3390/polym14020241] [Citation(s) in RCA: 2] [Impact Index Per Article: 0.7] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/15/2021] [Revised: 12/31/2021] [Accepted: 01/04/2022] [Indexed: 12/22/2022] Open
Abstract
The field of biosensing is in constant evolution, propelled by the need for sensitive, reliable platforms that provide consistent results, especially in the drug development industry, where small molecule characterization is of uttermost relevance. Kinetic characterization of small biochemicals is particularly challenging, and has required sensor developers to find solutions to compensate for the lack of sensitivity of their instruments. In this regard, surface chemistry plays a crucial role. The ligands need to be efficiently immobilized on the sensor surface, and probe distribution, maintenance of their native structure and efficient diffusion of the analyte to the surface need to be optimized. In order to enhance the signal generated by low molecular weight targets, surface plasmon resonance sensors utilize a high density of probes on the surface by employing a thick dextran matrix, resulting in a three-dimensional, multilayer distribution of molecules. Despite increasing the binding signal, this method can generate artifacts, due to the diffusion dependence of surface binding, affecting the accuracy of measured affinity constants. On the other hand, when working with planar surface chemistries, an incredibly high sensitivity is required for low molecular weight analytes, and furthermore the standard method for immobilizing single layers of molecules based on self-assembled monolayers (SAM) of epoxysilane has been demonstrated to promote protein denaturation, thus being far from ideal. Here, we will give a concise overview of the impact of tridimensional immobilization of ligands on label-free biosensors, mostly focusing on the effect of diffusion on binding affinity constants measurements. We will comment on how multilayering of probes is certainly useful in terms of increasing the sensitivity of the sensor, but can cause steric hindrance, mass transport and other diffusion effects. On the other hand, probe monolayers on epoxysilane chemistries do not undergo diffusion effect but rather other artifacts can occur due to probe distortion. Finally, a combination of tridimensional polymeric chemistry and probe monolayer is presented and reviewed, showing advantages and disadvantages over the other two approaches.
Collapse
Affiliation(s)
- Elisa Chiodi
- Department of Electrical Engineering, Boston University, Boston, MA 02215, USA; (A.M.M.); (M.B.); (N.L.Ü.)
- Correspondence: (E.C.); (M.S.Ü.)
| | - Allison M. Marn
- Department of Electrical Engineering, Boston University, Boston, MA 02215, USA; (A.M.M.); (M.B.); (N.L.Ü.)
- School of Engineering, Computing, and Construction Management, Roger Williams University, Bristol, RI 02809, USA
| | - Monireh Bakhshpour
- Department of Electrical Engineering, Boston University, Boston, MA 02215, USA; (A.M.M.); (M.B.); (N.L.Ü.)
- Department of Chemistry, Hacettepe University, Ankara 06800, Turkey
| | - Nese Lortlar Ünlü
- Department of Electrical Engineering, Boston University, Boston, MA 02215, USA; (A.M.M.); (M.B.); (N.L.Ü.)
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| | - M. Selim Ünlü
- Department of Electrical Engineering, Boston University, Boston, MA 02215, USA; (A.M.M.); (M.B.); (N.L.Ü.)
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
- Correspondence: (E.C.); (M.S.Ü.)
| |
Collapse
|
18
|
Bakhshpour M, Chiodi E, Celebi I, Saylan Y, Ünlü NL, Ünlü MS, Denizli A. Sensitive and real-time detection of IgG using interferometric reflecting imaging sensor system. Biosens Bioelectron 2022; 201:113961. [PMID: 35026547 DOI: 10.1016/j.bios.2021.113961] [Citation(s) in RCA: 3] [Impact Index Per Article: 1.0] [Reference Citation Analysis] [Abstract] [Key Words] [Track Full Text] [Journal Information] [Subscribe] [Scholar Register] [Received: 11/11/2021] [Revised: 12/20/2021] [Accepted: 12/31/2021] [Indexed: 11/16/2022]
Abstract
Considering the limitations of well-known traditional detection techniques, innovative research studies have focused on the development of new sensors to offer label-free, highly sensitive, real-time, low-cost, and rapid detection for biomolecular interactions. In this study, we demonstrate immunoglobulin G (IgG) detection in aqueous solutions by using real-time and label-free kinetic measurements of the Interferometric Reflectance Imaging Sensor (IRIS) system. By performing kinetic characterization experiments, the sensor's performance is comprehensively evaluated and a high correlation coefficient value (>0.94) is obtained in the IgG concentration range of 1-50 μg/mL with a low detection limit (0.25 μg/mL or 1.67 nM). Moreover, the highly sensitive imaging system ensures accurate quantification and reliable validation of recorded binding events, offering new perspectives in terms of direct biomarker detection for clinical applications.
Collapse
Affiliation(s)
- Monireh Bakhshpour
- Hacettepe University, Department of Chemistry, Ankara, Turkey; Boston University, Department of Electrical and Computer Engineering, Boston, MA, United States
| | - Elisa Chiodi
- Boston University, Department of Electrical and Computer Engineering, Boston, MA, United States
| | - Iris Celebi
- Boston University, Department of Electrical and Computer Engineering, Boston, MA, United States
| | - Yeşeren Saylan
- Hacettepe University, Department of Chemistry, Ankara, Turkey
| | - Nese Lortlar Ünlü
- Boston University, Department of Biomedical Engineering, Boston, MA, United States
| | - M Selim Ünlü
- Boston University, Department of Electrical and Computer Engineering, Boston, MA, United States; Boston University, Department of Biomedical Engineering, Boston, MA, United States
| | - Adil Denizli
- Hacettepe University, Department of Chemistry, Ankara, Turkey.
| |
Collapse
|
19
|
Priest L, Peters JS, Kukura P. Scattering-based Light Microscopy: From Metal Nanoparticles to Single Proteins. Chem Rev 2021; 121:11937-11970. [PMID: 34587448 PMCID: PMC8517954 DOI: 10.1021/acs.chemrev.1c00271] [Citation(s) in RCA: 56] [Impact Index Per Article: 14.0] [Reference Citation Analysis] [Abstract] [MESH Headings] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/31/2021] [Indexed: 02/02/2023]
Abstract
Our ability to detect, image, and quantify nanoscopic objects and molecules with visible light has undergone dramatic improvements over the past few decades. While fluorescence has historically been the go-to contrast mechanism for ultrasensitive light microscopy due to its superior background suppression and specificity, recent developments based on light scattering have reached single-molecule sensitivity. They also have the advantages of universal applicability and the ability to obtain information about the species of interest beyond its presence and location. Many of the recent advances are driven by novel approaches to illumination, detection, and background suppression, all aimed at isolating and maximizing the signal of interest. Here, we review these developments grouped according to the basic principles used, namely darkfield imaging, interferometric detection, and surface plasmon resonance microscopy.
Collapse
Affiliation(s)
| | | | - Philipp Kukura
- Physical and Theoretical
Chemistry Laboratory, Department of Chemistry, University of Oxford, South Parks Road, Oxford OX1 3QZ, United Kingdom
| |
Collapse
|
20
|
Chiodi E, Marn AM, Geib MT, Ünlü MS. The Role of Surface Chemistry in the Efficacy of Protein and DNA Microarrays for Label-Free Detection: An Overview. Polymers (Basel) 2021; 13:1026. [PMID: 33810267 PMCID: PMC8036480 DOI: 10.3390/polym13071026] [Citation(s) in RCA: 7] [Impact Index Per Article: 1.8] [Reference Citation Analysis] [Abstract] [Key Words] [Grants] [Track Full Text] [Download PDF] [Figures] [Journal Information] [Subscribe] [Scholar Register] [Received: 03/07/2021] [Revised: 03/23/2021] [Accepted: 03/23/2021] [Indexed: 01/04/2023] Open
Abstract
The importance of microarrays in diagnostics and medicine has drastically increased in the last few years. Nevertheless, the efficiency of a microarray-based assay intrinsically depends on the density and functionality of the biorecognition elements immobilized onto each sensor spot. Recently, researchers have put effort into developing new functionalization strategies and technologies which provide efficient immobilization and stability of any sort of molecule. Here, we present an overview of the most widely used methods of surface functionalization of microarray substrates, as well as the most recent advances in the field, and compare their performance in terms of optimal immobilization of the bioreceptor molecules. We focus on label-free microarrays and, in particular, we aim to describe the impact of surface chemistry on two types of microarray-based sensors: microarrays for single particle imaging and for label-free measurements of binding kinetics. Both protein and DNA microarrays are taken into consideration, and the effect of different polymeric coatings on the molecules' functionalities is critically analyzed.
Collapse
Affiliation(s)
- Elisa Chiodi
- Department of Electrical Engineering, Boston University, Boston, MA 02215, USA; (A.M.M.); (M.T.G.); (M.S.Ü.)
| | - Allison M. Marn
- Department of Electrical Engineering, Boston University, Boston, MA 02215, USA; (A.M.M.); (M.T.G.); (M.S.Ü.)
| | - Matthew T. Geib
- Department of Electrical Engineering, Boston University, Boston, MA 02215, USA; (A.M.M.); (M.T.G.); (M.S.Ü.)
| | - M. Selim Ünlü
- Department of Electrical Engineering, Boston University, Boston, MA 02215, USA; (A.M.M.); (M.T.G.); (M.S.Ü.)
- Department of Biomedical Engineering, Boston University, Boston, MA 02215, USA
| |
Collapse
|